1 Produktfamilie PRIMERGY RX200 S2 D1790 Setup Utility Hans-Joachim Kneba Fujitsu Siemens Computers GmbH Paderborn Paderborn Tel.: 05251/ Fax: (++49) 700 / A26361-D1790-Z Sprachen: En Edition September 2004

2 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps us optimize our documentation to suit your individual needs. Fax forms for sending us your comments are included in the back of the manual. There you will also find the addresses of the relevant User Documentation Department. Certified documentation according to DIN EN ISO 9001:2000 To ensure a consistently high quality standard and user-friendliness, this documentation was created to meet the regulations of a quality management system which complies with the requirements of the standard DIN EN ISO 9001:2000. cognitas. Gesellschaft für Technik-Dokumentation mbh Copyright and Trademarks Copyright 2004 Fujitsu Siemens Computers GmbH. All rights reserved. Delivery subject to availability; right of technical modifications reserved. All hardware and software names used are trademarks of their respective manufacturers. This manual is printed on paper treated with chlorine-free bleach.

3 Introduction Main menu Advanced menu Security menu Server menu Exit menu Abbreviations Index

4

5 Contents 1 Introduction Notational conventions Calling the Setup Utility Calling the Boot menu immediately Operating the Setup Utility Setup Utility Keys Main menu Primary Master Boot Options Advanced menu Peripheral Configuration PCI Configuration Configuring PCI components PCI IRQ Configuration Advanced System Configuration CPU Settings Power On/Off Security menu Server menu IPMI CPU Status Memory Status LAN Setting Console Redirection Exit menu Abbreviations Index A26361-D1790-Z

6

7 1 Introduction Most systems are already configures by the manufacturer or the dealer. There is no need to run the Setup Utility when starting the computer unless you get a Run Setup message. In the Setup Utility you can set the system functions and the hardware configuration of the device. When it is supplied, the device is set to factory default settings. You can change these settings in the Setup Utility. Any changes you make take effect as soon as you save the settings and quit the Setup Utility. You can select the following settings in the Setup Utility: Main Basic system information Advanced Further system information Security Security functions Server Server management Exit Save changes and exit Setup Utility I The individual menus and setting options are described in chronological order in the next chapters. Since the setting options and menus depend on the hardware configuration of your device, some of them may not be offered in the Setup Utility. 1.1 Notational conventions The meanings of the symbols and fonts used in this manual are as follows: V Pay particular attention to texts marked with this symbol. Failure to observe this warning endangers your life, destroys the system, or may lead to loss of data. I Supplementary information, remarks, and tips follow this symbol. Ê Text which follows this symbol describes activities that must be performed in the order shown. Typewriter text indicates system output. Italics in continuous text indicate display items. A26361-D1790-Z

8 Calling the Setup Utility Introduction 1.2 Calling the Setup Utility Ê Ê Ê Restart the device (switching On/Off or warm boot). The following message is displayed at the lower edge of the screen: F2: Enter Setup, F12: Boot Menu Press the [F2] key to enter the Setup Utility. If you have assigned a supervisor password, you must now enter this password and confirm it with the [Enter] key. The Main menu of the Setup Utility is displayed on the screen: PhoenixBIOS Setup Utility Main Advanced Security Server Exit System Time [16:19:20] System Date: [03/02/1994] Diskette A: [1.44/1.25 MB 3½ ] Item Specific Help <Tab>, <Shift-Tab>, or <Enter> selects field Primary Master Boot Options Base Memory Extended Memory [CD-ROM] 624 kb kb F1 Info Select Item -/+ Change Values F9 Setup Defaults ESC Exit Select Menu Enter Select Sub-Menu F10 Save and Exit I A [Ê] to the left of an item indicates that this item contains a submenu. By pressing the [F1] key, a help window appears on the screen (not to confuse with the Item Specific Help). There you can get information about the system. 2 A26361-D1790-Z

9 Introduction Calling the Boot menu immediately 1.3 Calling the Boot menu immediately You may use this function if you do not want to boot the system from the drive specified as first device in the Boot Options > Boot Sequence item of the Main menu. Ê Press the [F12] key. After a while, the Boot menu appears as pop up window on the screen (only if several devices are available). Ê Select from which drive you want to boot the operating system or call the Setup Utility by using the keys Ê or Ë and then press the [Enter] key. I Your selection is only valid for the current system boot. At the next system boot, the options selected in the Boot Options > Boot Sequence item of the Main menu are valid again. A26361-D1790-Z

10 Operating the Setup Utility Introduction 1.4 Operating the Setup Utility To select a menu, press the keys À or Â. To select an item in a Setup Utility menu, move the highlight bar by using the keys Ê or Ë and then press the [Enter] key. To increase or decrease a value for the selected item, press the keys [+] or [-] until the desired value is found. I If you change entries in the Setup Utility, make a note of the changed entries! 1.5 Setup Utility Keys Key À Â Ê Ë [Enter] [Esc] Function Select a menu Select an item in a (sub)menu Execute a menu-dependent action Leave a submenu or, if you are on the highest menu level, go to the Exit menu [F1] Display system Information [+] [-] Change values 4 A26361-D1790-Z

11 2 Main menu PhoenixBIOS Setup Utility Main Advanced Security Server Exit System Time [16:19:20] System Date: [03/02/1994] Diskette A: [1.44/1.25 MB 3½ ] Item Specific Help <Tab>, <Shift-Tab>, or <Enter> selects field Primary Master Boot Options Base Memory Extended Memory [CD-ROM] 624 kb kb F1 Info Select Item -/+ Change Values F9 Setup Defaults ESC Exit Select Menu Enter Select Sub-Menu F10 Save and Exit System Time indicates the system time of the device in the format HH:MM:SS. You also can set the time manually. If the time is frequently wrong when powering up the system, the lithium battery is dead. System Date indicates the system date of the device in the format MM/DD/YY. You also can set the date manually. If the date is frequently wrong when powering up the system, the lithium battery is dead. Diskette A specifies the type of the floppy disk drive. The value depends on the drive installed. If Disabled is shown, no floppy disk drive is installed. Primary Master calls a submenu for setting of the disk drive parameters (see section Primary Master on page 6) Boot Options calls a submenu for setting the boot parameters (see section Boot Options on page 8). Base Memory indicates the size of the base memory below one Mbyte. Extended Memory indicates the size of the memory above one Mbyte. A26361-D1790-Z

12 Primary Master Main menu 2.1 Primary Master Main l PhoenixBIOS Setup Utility Primary Master [CD-ROM] Item Specific Help Type: [Auto] Transfers mode: [Disabled] LBA Translation: [Disabled] PIO Mode: [FPIO 4 / DMA 2] 32 Bit I/O: [Disabled] Ultra DMA Mode: [Mode 2] User = you enter parameters of hard-disk drive installed at this connection. Auto = autotypes Hard-disk installed here. CD-Rom = a CD-ROM drive is installed here. ATAPI Removable = removable disk drive is installed here. F1 Info Select Item -/+ Change Values F9 Setup Defaults ESC Exit Select Menu Enter Select Sub-Menu F10 Save and Exit Type specifies the type of installed disk drive: Auto If the disk drive supports this mode, the setup utility reads the parameters from the disk itself. You do not need to set the parameters yourself. CD-ROM If a CD-ROM drive is installed, this parameter enables you to boot from the CD-ROM drive. IDE Removable If a removable IDE disk drive is installed, this parameter enables you to boot from the correspondent drive. ATAPI Removable If a removable ATAPI disk drive is installed, this parameter enables you to boot from the correspondent drive. Other ATAPI If a another ATAPI disk drive is installed, this parameter enables you to boot from the correspondent drive. User You can enter the disk parameters cylinders, heads, sectors and capacity yourself. None No disk drive installed. 6 A26361-D1790-Z

13 Main menu Primary Master Transfer Mode specifies the number of sectors per bloc for multiple sector transfer: Disabled Multiple sector transfer is not activated. 2 Sectors, 4 Sectors, 8 Sectors, 16 Sectors Multiple sector transfer is activated. If LBA Translation is set, blocks are transmitted, otherwise sectors. LBA Translation converts the physical formatting of disks in cylinders, heads and sectors so that the generated logical values lie within the BIOS limitations. This means that a disk capacity of over 528 Mbyte can be supported. Enabled If the disk supports LBA and it has a capacity of more than 528 Mbytes, BIOS translates the disk parameters. Disabled BIOS uses the disk parameters and supports a maximum capacity of 528 Mbytes. I Change the entries only if you are installing another disk drive. PIO Mode defines the transfer rate of the disk drive. If possible use the Auto parameter in the Type item. This means BIOS will determine the best possible transfer rate for the disk drive. Disabled The transfer rate is not set. Standard 2 Mbyte to 4 Mbyte per second Fast PIO 1 2 Mbyte to 4 Mbyte per second Fast PIO 2 4 Mbyte to 5 Mbyte per second Fast PIO 3 5 Mbyte to 10 Mbyte per second Fast PIO 4 10 Mbyte to 16 Mbyte per second FPIO 3 / DMA 1 5 Mbyte to 10 Mbyte per second FPIO 4 / DMA 2 up to 16 Mbyte per second I If transfer rates are set incorrectly, the disk drive will be either too slow, does not boot correctly or does not respond. A26361-D1790-Z

14 Boot Options Main menu 32 Bit I/O specifies the width of data transmission between the processor and the controller (Enabled = 32 Bit, Disabled = 16 Bit). Ultra DMA Mode specifies the fast Ultra DMA transfer mode for the disk drive: Mode 0 = 16,7 MB/s, Mode 1 = 25,0 MB/s, Mode 2 = 33,3 MB/s or not (Disabled). 2.2 Boot Options Main l Boot Options PhoenixBIOS Setup Utility Item Specific Help POST Errors: Keyboard Check: SM Error Halt: Quick Boot: Quiet Boot: Memory Testing: Boot Menu: Boot Sequence MultiBoot for HDs: [Disabled] [Disabled] Pauses and displays SETUP entry or resume boot prompt if error occurs on boot. If disabled, system always attempts to boot. F1 Info Select Item -/+ Change Values F9 Setup Defaults ESC Exit Select Menu Enter Select Sub-Menu F10 Save and Exit POST Errors specifies whether the system start-up is to be aborted and the system halted when an error is detected during the self-test (Enabled) or not (Disabled). If Disabled is set, the error is ignored as far as possible Keyboard Check specifies whether keyboard checks are carried out (Enabled) or not (Disabled). This setting is useful for systems which are operated without a keyboard. If Enabled is set, the system behaves as defined in the POST Errors item. If Disabled is set, possible keyboard faults are not detected. 8 A26361-D1790-Z

15 Main menu Boot Options SM Error Halt specifies the system behavior during the self-test in case of a system monitoring error reported by the BMC (e.g. fan monitoring, temperature monitoring). This setting is only effective when Enabled is set in the POST Errors item. Enabled If an error is reported, the system start-up is cancelled and the system stopped following the self-test. Disabled If an error is reported, the system start-up is not cancelled. An error message is displayed only. Quick Boot specifies whether a quick self-test is carried out (Enabled) or the complete device configuration is tested (Disabled) when the device is switched on. Quiet Boot specifies whether a logo (Enabled) or the POST information is displayed on the screen (Disabled) during the boot routine. If Enabled, a switch to the POST information is made by pressing the [F3] or the [Esc] key or if an error occurs. Memory Testing specifies whether a memory test is running during the boot routine of the BIOS (Enabled) or not (Disabled). Boot Menu specifies whether the BOOT menu can be invoked with [F12] during the POST (Enabled) or not (Disabled). Boot Sequence specifies the sequence of the system files that the system BIOS requires during the boot routine: CD-ROM Drive Removable Devices Hard Drive The system is booted from a CD-ROM. The system is booted from a removable device. The system is booted from hard disk. MultiBoot for HD s determines whether Hard Drive specifies the boot sequence (Enabled) or not (Disabled). If Disabled is set, the operating system is started from the drive that is found first by the BIOS, i.e. the selection of the PCI slot has an influence on the boot sequence. A26361-D1790-Z

16

17 3 Advanced menu PhoenixBIOS Setup Utility Main Advanced Security Server Exit Setup warning Setting items on this menu to incorrect Values may cause your system to malfunction Peripheral Configuration PCI Configuration Advanced System Configuration Power On/Off Reset Configuration Data: [No] Secured Setup Configurations [Disabled] Multiprocessor Specification: [1.4] Large Disk Access Mode: [DOS] Item Specific Help Peripheral configuration F1 Info Select Item -/+ Change Values F9 Setup Defaults ESC Exit Select Menu Enter Select Sub-Menu F10 Save and Exit Peripheral Configuration calls a submenu to configure the serial port (see section Peripheral Configuration on page 13). PCI Configuration calls a submenu to configure PCI components (see section PCI Configuration on page 14). Advanced System Configuration calls a submenu to make additional settings (see section Advanced System Configuration on page 17). Power On/Off calls a submenu which specifies how the system can be powered on and off in the same way as using the power switch on the system unit (see section Power On/Off on page 21). A26361-D1790-Z

18 Advanced menu Reset Configuration Data specifies whether the configuration data is reset and reinitialized when the system is started. Yes No After the system is started, the configuration data is reset, and the parameter is set to No. The new configuration data is determined by means of the Plug and Play functionality. The mounted boards and drives are initialized with this data. Non-Plug and Play components must be entered manually (e.g. Windows, ICU). After the system is started, the Plug and Play functionality ascertains the current configuration data and uses this data to initialize the installed boards and drives. The configuration data of non- Plug and Play components are not reset. Secured Setup Configurations prevents a Plug and Play operating system from changing system settings (Yes) or deactivates this function (No). Multiprocessor Specification specifies the version of the multiprocessor table. The multiprocessor table is needed by multiprocessor operating systems to recognize the multiprocessor characteristics of the system. Large Disk Access Mode specifies the type of hard disk access for large hard disks (more than 1024 cylinders, 16 heads). The default setting depends on the operating system used. DOS The operating system uses MS-DOS compatible hard disk accesses. Other The operating system uses hard disk accesses which are not MS- DOS compatible (e.g. Novell, SCO UNIX). I If you are installing a new software and the drive fails, change this selection and try again. Different operating systems require different representations of drive geometries. 12 A26361-D1790-Z

19 Advanced menu Peripheral Configuration 3.1 Peripheral Configuration PhoenixBIOS Setup Utility Main Advanced Security Server Exit Peripheral Configuration Item Specific Help Serial: Serial Multiplexer: Floppy Type: Diskette Controller: Mouse Controller: [Disabled] [System] [Local] [Auto Detect] Configure serial port using options: [Disabled] No configuration User configuration [Auto] BIOS or OS chooses configuration <OS Controlled> Displayed when controlled by OS. F1 Info Select Item -/+ Change Values F9 Setup Defaults ESC Exit Select Menu Enter Select Sub-Menu F10 Save and Exit Serial specifies the address and the interrupt used to access the serial port. Enabled The port is set to the shown address and interrupt. If Enabled is set, additional lines are displayed for setting the configuration. Auto The port is automatically set to the next available combination (address, interrupt). Disabled The port is disabled. Serial Multiplexer specifies whether the interface can be used by the system (System), the BMC. (BMC), or both (Shared). Floppy Type specifies which floppy disk controller is to be used. Local The default floppy disk controller of the system is used. Remote The controller for remote access permits access to a floppy disk drive of another system or to a floppy-disk image file stored on another system. The data are routed via the network in this case. A26361-D1790-Z

20 PCI Configuration Advanced menu Remote Once The floppy disk controller for remote access is used for the subsequent system start-up. Then the system automatically switches over to Local. Diskette Controller specifies whether the built-in floppy disk controller on the system board is Enabled (IRQ 6 is used) or Disabled (IRQ 6 is free). Mouse Controller specifies whether the built-in mouse controller on the system board is Enabled (IRQ 12 is used) or Disabled (IRQ 12 is free). 3.2 PCI Configuration PhoenixBIOS Setup Utility Main Advanced Security Server Exit Ethernet on Board PCI Configuration PCI Device, Embedded LSI SCSI 1020 PCI IRQ Configuration PCI Slots Configuration Item Specific Help Setup items for configuration the specific PCI device. F1 Info Select Item -/+ Change Values F9 Setup Defaults ESC Exit Select Menu Enter Select Sub-Menu F10 Save and Exit Ethernet on Board PCI Device, Embedded LSI SCSI 1020 PCI Slots Configuration call corresponding submenus for configuring the appropriate PCI component (see section Configuring PCI components on page 15). PCI IRQ Configuration calls a submenu for the port-specific allocation from PCI interrupts to ISA interrupts (see section PCI IRQ Configuration on page 16). 14 A26361-D1790-Z

21 Advanced menu PCI Configuration Configuring PCI components PhoenixBIOS Setup Utility Main Advanced Security Server Exit Ethernet on Board Item Specific Help PCI Device, Embedded Ethernet 1 Device: Option ROM Scan: Latency Timer: PCI Device, Embedded Ethernet 2 Device: Option ROM Scan: Latency Timer: [Disabled] [0040h] [Disabled] [0040h] Enables/Disables this PCI device on board. F1 Info Select Item -/+ Change Values F9 Setup Defaults ESC Exit Select Menu Enter Select Sub-Menu F10 Save and Exit PhoenixBIOS Setup Utility Main Advanced Security Server Exit PCI Device, Embedded LSI SCSI 1020 PCI Device, Embedded LSI SCSI 1020 Device: Option Rom Scan: Latency Timer: [0040h] Item Specific Help Enables/Disables this PCI device on board F1 Info Select Item -/+ Change Values F9 Setup Defaults ESC Exit Select Menu Enter Select Sub-Menu F10 Save and Exit PhoenixBIOS Setup Utility Main Advanced Security Server Exit PCI Slots Configuration Item Specific Help PCI Slot 1 Configuration Option ROM Scan: Bus Master: Latency Timer: PCI Slot 2 Configuration Option ROM Scan: Bus Master: Latency Timer: [Disabled] [Disabled] [0040h] [Disabled] [Disabled] [0040h] Initialize device expansion ROM. F1 Info Select Item -/+ Change Values F9 Setup Defaults ESC Exit Select Menu Enter Select Sub-Menu F10 Save and Exit Dependant on the respective submenu the following parameters can be set (in alphabetical order): Bus Master specifies whether the PCI slot acts as a busmaster (Enabled) or not (Disabled). A26361-D1790-Z

22 PCI Configuration Advanced menu Device specifies whether the respctive controller is used (Enabled) or not (Disabled). Latency Timer specifies the guaranteed minimum of time, which is assigned to the PCI slot. Option ROM Scan specifies whether the BIOS of the adapter in the respective PCI slot is started by the BIOS of the system (Enabled) or not (Disabled). I To load an operating system from an adapter (e.g. SCSI, LAN), the related adapter must be controlled by a BIOS PCI IRQ Configuration PhoenixBIOS Setup Utility Main Advanced Security Server Exit PCI IRQ Configuration Item Specific Help PCI IRQ Line 0/VGA [Auto] Set PCI IRQ mapping. This line is connected to VGA INT A. A PCI device cannot use IRQs already in use by ISA devices. Use Auto for a Plug and Play compliant configuration. F1 Info Select Item -/+ Change Values F9 Setup Defaults ESC Exit Select Menu Enter Select Sub-Menu F10 Save and Exit PCI IRQ Line 0/VGA Auto The PCI interrupts are assigned automatically in accordance with the Plug and Play guidelines. IRQ# The PCI interrupt is switched to the selected ISA interrupt. You may not select an ISA interrupt that is used by an ISA component on the mainboard (e.g. controller) or an ISA board. Disabled No ISA interrupt is assigned to the PCI interrupt. I If you use a setting other than Auto, the Plug and Play functionality of the System BIOS for the corresponding PCI boards is deactivated. 16 A26361-D1790-Z

23 Advanced menu Advanced System Configuration 3.3 Advanced System Configuration PhoenixBIOS Setup Utility Main Advanced Security Server Exit Advanced System Configuration Item Specific Help CPU Settings: USB 1.1 Host Controller: USB 2.0 Host Controller: USB BIOS Legacy Support: BIOS Work Space Location: [Top of Base memory] Memory Redundancy: [Mirroring] F1 Info Select Item -/+ Change Values F9 Setup Defaults ESC Exit Select Menu Enter Select Sub-Menu F10 Save and Exit CPU Settings calls a submenu to make CPU settings (see section CPU Settings on page 19). USB <x.x> Host Controller specifies whether the USB hardware is switched on (Enabled) or not (Disabled). If this function is deactivated, the corresponding USB host controller will not be recognized by any operating system. As a result, no USB devices can be operated. USB BIOS Legacy Support specifies whether the USB keyboard and USB mouse emulation is still active after starting the operating system (Enabled) or not (Disabled). If an USB keyboard is used, the emulation for the BIOS setup is always switched on. This function is also required when the operating system is to be booted from an USB device. If the function is enabled, the USB keyboard or USB mouse can also be used under operating systems that do not support USB. The operating system can be booted from an USB device if the operating system also supports it. To operate an USB keyboard or USB mouse, it must be supported by the operating system if the function is disabled. The operating system cannot be loaded from an USB device. A26361-D1790-Z

24 Advanced System Configuration Advanced menu BIOS Work Space Location specifies where the data area for extended BIOS functions is located. Expansion ROM Area The data area is located within the area of the BIOS expansions. Top of Base Memory The data area is located in the working memory directly below the 640 Kbyte limit. This setting should only be used when BIOS extensions, e.g. SCSI, can not be loaded from the system BIOS. Memory Redundancy Sparing Sparing reserves the last memory bank for replacing a bank with too many correctable errors. Mirroring Mirroring divides the system memory in half and maintains two copies off all data in memory. It prevents the system from crashing in case of uncorrectable memory errors. Disabled Memory Redundancy is disabled. 18 A26361-D1790-Z

25 Advanced menu Advanced System Configuration CPU Settings PhoenixBIOS Setup Utility Main Advanced Security Server Exit CPU Settings Item Specific Help CPU Mismatch Detection: Hyper Threading: Fast String operations Compatible FPU Code Spit Lock operations Adjacent Sector Prefetch: [Disabled] Enable detection of CPU frequency change and from side bus frequency mismatch. F1 Info Select Item -/+ Change Values F9 Setup Defaults ESC Exit Select Menu Enter Select Sub-Menu F10 Save and Exit CPU Mismatch Detection Enables/Disables detection of CPU frequency change and front side bus frequency mismatch. Hyper Threading specifies whether an ACPI operating system can use all logical CPUs within a physical CPU (Enabled) or only the first logical CPU of the physical CPU (Disabled). Hyper-threading technology allows a single physical processor to appear as several logical processors.this setting has no effect on operating systems that do not support ACPI. Fast String Operations activates (Enabled) or deactivates (Disabled) the fast string operation function of the CPU. This is an adjustment option of the CPU to effect optimised string operations. Cache procedures are optimised and interrupts are only admitted on cacheline boundaries. I You will find more information under in the document "IA-32 Intel Architecture Software Developers Manual Vol 1-3" under the keyword "Out-of-Order Stores for String Operations". A26361-D1790-Z

26 Advanced System Configuration Advanced menu Compatible FPU Code activates (Enabled) or deactivates (Disabled) P6, the compatible FPU operation code register model. I You will find more information under in the document "IA-32 Intel Architecture Software Developers Manual Vol 1-3" under the keyword "Guidelines for writing x87 FPU Exception Handlers". Spit Lock Operations activates (Enabled) or deactivates (Disabled) the split lock feature of the CPU. This feature describes whether an allignment check exception is activated during a transaction which splittes an acheline or a page. Adjacent Sector Prefetch specifies whether the CPU reads complete cache lines (Enabled) or only the sector of a cache line (Disabled), which contains the required data. I With this option you can make performance settings for exceeding applications. Fujitsu Siemens Computers recommends for standart applications not to deviate from the default settings. 20 A26361-D1790-Z

27 Advanced menu Power On/Off 3.4 Power On/Off PhoenixBIOS Setup Utility Main Advanced Security Server Exit Power On/Off Power On Source Remote: Resume On Times: [Off] Resume Time: [00:00:00] LAN: Power Failure Recovery: [Previous State] Item Specific Help Allows the system be switched on via an external hardware signal. F1 Info Select Item -/+ Change Values F9 Setup Defaults ESC Exit Select Menu Enter Select Sub-Menu F10 Save and Exit Power On Source: Remote specifies whether the system can be switched on by an incoming message, e.g. via modem, fax or telephone, (Enabled) or not (Disabled). The signal can be supplied externally via serial port 1 or internally via the modem on connector. Power On Source: Resume On Time specifies whether the system is waked up after a social time (Enabled) or not (Disabled). Power On Source: Resume Time specifies the time for waking up the system, when Resume On Time is set to On. Power On Source: LAN specifies whether the system can be switched on by means of a LAN controller (Enabled) or not (Disabled). Power Failure Recovery specifies the status to which the system shall return after a power failure. Always Off The system ist shut down. Always On The system is restarted. Previous State The system returns to the last state before the power failure occurred. A26361-D1790-Z

28

29 4 Security menu PhoenixBIOS Setup Utility Main Advanced Security Server Exit Setup Password System Password Set Setup Password: Set System Password: Setup Password Lock: System Password Mode: SETUP Prompt: Virus Warning: System Load: Diskette Write: Flash Write: Not installed Not installed [Enter] [Enter] [Standard] [System] [Standard] Item Specific Help Supervisor Password controls access to the setup utility. F1 Info Select Item -/+ Change Values F9 Setup Defaults ESC Exit Select Menu Enter Select Sub-Menu F10 Save and Exit Setup Password / System Password displays whether a setup password and a system password is set (Installed) or not (Not Installed). Set Setup Password opens a window after pressing the [ENTER] key. Here you can assign the setup password. The setup password prevents an unauthorized calling of the BIOS Setup. If you want to delete the setup password without assigning a new one, enter a blank instead of a new password. I With the deletion of the setup password the system password is also deleted. Set System Password opens a window after pressing the [ENTER] key. Here you can assign the system password. The system password prevents the unauthorized access to the system. If you want to delete the system password without assigning a new one, enter a blank instead of a new password. Condition: A setup password is set. A26361-D1790-Z

30 Security menu Setup Password Lock prevents an unauthorized access to the settings of devices with its own BIOS. An Adapter BIOS can be branched or not. If you want to disable this feature delete the system password. Standard Processing boot without Adapter BIOS lock. The setup password is deactivated when booting. Extended Processing boot with Adapter BIOS lock. To enter the Adapter BIOS Setup is impossible. If you want to disable this feature delete the system password. Condition: A setup password is set. System Password Mode suspends the boot process until the system password is entered. Condition: A setup password and a system password is set. SETUP Prompt specifies whether the setup prompt is displayed while booting (Enabled) or not (Disabled). Virus Warning allows to check the boot sectors of the hard disk to see if any changes have been made since the previous system boot. If the boot sectors have been changed and the reason for this is unknown, a program for finding computer viruses should be loaded. Enabled If the boot sector has been changed since the previous system boot (e.g. new operating system or virus attack), a warning is displayed. The warning stays on the screen until you acknowledge the changes with Confirm or deactivate the function. Disabled The boot sectors are not checked. System Load This value is not changeable. Diskette Write activates (Enabled) or deactivates (Disabled) the diskette write protection. Flash Write activates (Enabled) or deactivates (Disabled) the BIOS write protection. 24 A26361-D1790-Z

31 5 Server menu PhoenixBIOS Setup Utility Main Advanced Security Server Exit O/S Boot Timeout: [Disabled] Mode [Continue] Timeout Value [0] ASR&R Boot Delay (min): [2] Power Cycle Delay: [5] Boot Retry Counter: [3] Diagnostic System: [Disabled] Critical Temperature Monitoring: [Disabled] Memory Scrub: BIOS runtime logging: Clear Screen Delay (sec): [5] IPMI CPU Status Memory Status LAN Setting Console Redirection Item Specific Help A system reset via ASR&R takes place after the specified timeout, if OS boot failed or ServerView agent is not connected. F1 Info Select Item -/+ Change Values F9 Setup Defaults ESC Exit Select Menu Enter Select Sub-Menu F10 Save and Exit O/S Boot Timeout supervises the OS boot process. If an error occurs during the OS boot phase, the boot process is aborted and a log message is written (Enabled) or not (Disabled). Mode specifies the action that takes place after the boot watchdog has expired (if O/S Boot Timeout is set to Enabled). Continue The system continues booting. Reset The system is shut down and restarted (warm boot). Power Cycle The system is switched off and restarted after waiting a moment (cold boot). Timeout Value specifies the time (in minutes) after which the boot watchdog has to run (if O/S Boot Timeout is set to Enabled). Within this time the operating system has to be loaded, if not, the boot watchdog intervenes. 0 The boot watchdog is disabled A value >0 specifies a boot watchdog time. A26361-D1790-Z

32 Server menu ASR&R Boot Delay (min) specifies the boot delay time (1-30 minutes) after a shutdown due to a critical condition (e.g. excessively high temperature). The system is rebooted after the set wait period has expired. Power Cycle Delay specifies the minimum time (0-15 seconds) between power off and consecutive power on. Boot Retry Counter specifies the maximum number of attempts (0-7) to boot the system. Diagnostic System specifies whether the diagnostic system is started (via LAN or Remote Image Disk) or not (Disabled) after the number of reboots defined in Boot Retry Counter has expired. Critical Temperature Monitoring specifies whether the system is switched off (Enabled) or not (Disabled) if the ambient temperature or the temperature of a processor exceeds a critical value. Memory Scrub specifies whether memory will be screened and one-bit errors will be corrected (Enabled) or not (Disabled). Clear Screen Delay (sec) specifies the time (0-32 seconds) the last screen with BIOS messages remains visible before the operating system is started. IPMI calls a submenu with the Intelligent Platform Management Interface settings. The behavior of the Baseboard Management Controller is specified and information displayed here (see section IPMI on page 27). CPU Status calls a submenu for setting the CPU status (see section CPU Status on page 29) Memory Status calls a submenu for setting the memory status (see section Memory Status on page 30). LAN Setting calls a submenu for setting BMC LAN parameters (see section LAN Setting on page 31). 26 A26361-D1790-Z

33 Server menu IPMI Console Redirection calls a submenu for setting terminal parameters (see section Console Redirection on page 32) 5.1 IPMI PhoenixBIOS Setup Utility Main Advanced Security Server Exit IPMI IPMI Specification Version 1.5 BMC Firmware Clear System Event Log [Disabled] Event Log Full Mode [Overwrite] Existing Event Log number 40 Remaining Event Log number 214 System Event Log System Event Log (list mode) Real-time Sensor Data Item Specific Help Enable/Disable IPMI event logging. Disabling will still log events received via the system interface. F1 Info Select Item -/+ Change Values F9 Setup Defaults ESC Exit Select Menu Enter Select Sub-Menu F10 Save and Exit IPMI Specification Version / BMC Firmware displays the IPMI version / BMC version. Clear System Event Log specifies whether the System Event Log is to be cleared during the next system start-up (Enabled) or not (Disabled). Event Log Full Mode specifies whether the System Event Log can be overwritten (Enabled) or not (Disabled). Maintain If the System Event Log is full, no further events are entered. The System Event Log must be cleared first before additional events can be entered. Overwrite If the System Event Log is full, additional events overwrite the oldest entries of the System Event Log. Existing Event Log Number displays the number of existing entries in the Event Log (0-254). Remaining Event Log Number displays the number of remaining entries in the Event Log. A26361-D1790-Z

34 IPMI Server menu System Event Log opens the window of the System Event Log Browser. In this window the events with some properties are displayed. You can also display the information in a list mode. PhoenixBIOS Setup Utility Main Advanced Security Server Exit System Event Log Entry Number = 1 Record ID = 0001 Record Type = 02 System Event Record Timestamp = 28/08/ :51:18 Generator Id = EvM Rev = 03 Sensor Type = 10 Event Logging Disabled Sensor Number = 97 Event Disable Event Type = 6F Event Data = 02 FF FF SEL Event = -- F1 Info Select Item -/+ Change Values F9 Setup Defaults ESC Exit Select Menu Enter Select Sub-Menu F10 Save and Exit Realtime Sensor Data opens a window in which the values of different sensors are displayed. PhoenixBIOS Setup Utility Main Advanced Security Server Exit Thermal Sensor 154 Fan Speed Sensor 0 Real-time Sensor Data Item Specific Help All items on this menu cannot be modified in user mode. If any items require changes, please consult your system supervisor F1 Info Select Item -/+ Change Values F9 Setup Defaults ESC Exit Select Menu Enter Select Sub-Menu F10 Save and Exit 28 A26361-D1790-Z

35 Server menu CPU Status 5.2 CPU Status PhoenixBIOS Setup Utility Main Advanced Security Server Exit CPU Status Item Specific Help CPU 0 Status: CPU 1 Status: If a CPU is failed but equipped, the Service Processor has stopped the CPU on demand or due to CPU errors. Status of empty CPU slot is unchangeable. The Boot Strap CPU <*> is marked. F1 Info Select Item -/+ Change Values F9 Setup Defaults ESC Exit Select Menu Enter Select Sub-Menu F10 Save and Exit CPU # Status specifies whether a CPU can be used or not. Switch off a CPU only if it has reported an internal error. The error is recorded in the error log, which you can view with the SCU (Server Configuration Utility), RemoteView or ServerView programs. Enabled The CPU can be used by the operating system. Failed The CPU cannot be used by the operating system. As long as the status is Failed, an entry is generated in the System Event Log during each system start-up. Disabled The CPU cannot be used by the operating system. I If only one CPU is present, the setting of this parameter is ineffective. Even if only one CPU is installed, the status of all possible CPUs is displayed. Even if Disabled or Failed is entered for all CPUs, one CPU is used for booting. A26361-D1790-Z

36 Memory Status Server menu 5.3 Memory Status PhoenixBIOS Setup Utility Main Advanced Security Server Exit Memory Status Item Specific Help Channel A DIMM A1: DIMM A2: DIMM A3: DIMM A4: Channel B DIMM B1: DIMM B2: DIMM B3: DIMM B4: If the status for one or more memory modules is failed, the system reduces the memory, and tries to boot with the reduced memory.. F1 Info Select Item -/+ Change Values F9 Setup Defaults ESC Exit Select Menu Enter Select Sub-Menu F10 Save and Exit DIMM ## specifies the status of the corresponding memory module. Enabled If the bank is equipped, the memory module is used by the system. Failed The memory module is not used by the system. Faulty memory modules are no longer used when the system is rebooted provided at least one errorfree bank is available. If you have replaced a defective memory module, you must reset the item to Enabled. As long as the module status is Failed, an entry is generated in the System Event Log during each system start-up. Disabled The memory module is not used by the system. 30 A26361-D1790-Z

37 Server menu LAN Setting 5.4 LAN Setting PhoenixBIOS Setup Utility Main Advanced Security Server Exit LAN Setting Local IP Address: [ ] Subnet Mask: [ ] Gateway Address: [ ] User ID 1 Password [ ] Item Specific Help Information to set the BMC IP address. F1 Info Select Item -/+ Change Values F9 Setup Defaults ESC Exit Select Menu Enter Select Sub-Menu F10 Save and Exit Local IP Address Enter the IP address of the system LAN board here. Use the same IP address you have specified on the OS network for the used network card. Subnet Mask Enter the subnet mask of the system LAN board here. Use the same subnet mask you have specified on the OS network for the used network card. Gateway Address Enter the gateway address of the system LAN board here. Use the same gateway address you have specified on the OS network for the used network card. User ID 1 Password Enter the password for the authentication of the default user. To write the password to the BMC, press the [Enter] key. A26361-D1790-Z

38 Console Redirection Server menu 5.5 Console Redirection PhoenixBIOS Setup Utility Main Advanced Security Server Exit Console Redirection Console Redirection Port: Port: [Serial 1] Media Type: [Serial] Console Connection: [Direct] Baud Rate [9600] Protocol: [VT100+] Flow Control [None] Mode: [On] Item Specific Help Enables the console redirection. F1 Info Select Item -/+ Change Values F9 Setup Defaults ESC Exit Select Menu Enter Select Sub-Menu F10 Save and Exit Console Redirection Port enables or disables the Console Redirection function. Port specifies the port for communication with the terminal. Media Type specifies the interface for the terminal connection (Serial, LAN or Serial+LAN). Console Connection specifies whether the console is connected directly to the system or via modem. Baud Rate specifies the baud rate for communication with the terminal. This setting must be identical on both the terminal and the server. Protocol specifies the transfer protocol for communication with the terminal. This setting must be identical on both the terminal and the server. 32 A26361-D1790-Z

39 Server menu Console Redirection Flow Control specifies how the transfer via the port is controlled. This setting must be identical on both the terminal and the server. None No transfer control. XON/XOFF Transfer control is carried out by software. CTS/RTS Transfer control is carried out by hardware. This mode must be supported by the cable. Mode specifies whether the Console Redirection continues during the OS loading process (Enhanced) or not (Standard). The terminal operating mode is only available during the boot process. A26361-D1790-Z

40

41 6 Exit menu PhoenixBIOS Setup Utility Main Advanced Security Server Exitoo Save Changes & Exit Discard Changes & Exit Get Default Values Load Previous Values Save Changes Item Specific Help Exit System Setup and save your changes to CMOS. F1 Info Select Item -/+ Change Values F9 Setup Defaults ESC Exit Select Menu Enter Select Sub-Menu F10 Save and Exit Save Changes & Exit saves the settings you have made into CMOS, exits BIOS Setup and reboots the computer. When you boot the computer the next time, the BIOS will reconfigure the system according to the data in CMOS. You can press the [F10] key alternatively. Discard Changes & Exit exits BIOS Setup without saving the modified settings and reboots the computer. Get Default Values reverts all settings to the default values. You can press the [F9] key alternatively. Load Previous Values sets the values which were in effect when BIOS Setup was called. Save Changes saves the settings you have made without leaving BIOS Setup. After selecting an item and pressing [Enter] a window appears on the screen where you have to confirm the execution. A26361-D1790-Z

42

43 Abbreviations ACPI Advanced Configuration and Power Interface ASR&R Automatic Server Recovery and Reboot ATAPI Attachment Packet Interface BIOS BMC Basic Input Output System Baseboard Management Controller CMOS Complementary Metal Oxide Semiconductor CTS/RTS Clear To Send/Ready To Send DMA FPU IDE IPMI IRQ ISA Direct Memory Access Floating-Point Unit Integrated Drive Electronics Intelligent Platform Management Interface Interrupt Request Line Industry Standard Architecture A26361-D1790-Z

44 Abbreviations LBA PCI PIO Logical Block Addressing Peripheral Component Interconnect Programmed Input Output POST Power-On Self Test USB Universal Serial Bus 38 A26361-D1790-Z

45 Index A advanced menu 11 advanced system configuration 17 B boot options 8 C calling the boot menu immediately 3 calling the setup utility 2 console redirection 32 CPU settings 19 CPU status 29 E exit menu 35 I IPMI 27 L LAN settings 31 M main menu 5 memory status 30 O operating the setup utility 4 P PCI components, configuring 15 PCI configuration 14 PCI IRQ configuration 16 peripheral configuration 13 power on/off 21 primary master 6 S security menu 23 server menu 25 setup utility keys 4 A26361-D1790-Z

46

47 Fujitsu Siemens Computers GmbH User Documentation Paderborn Germany Fax: (++49) 700 / Comments Suggestions Corrections manuals@fujitsu-siemens.com Submitted by Comments on PRIMERGY RX200 S2 D1790 Setup Utility A26361-D1790-Z

48

49 Fujitsu Siemens Computers GmbH User Documentation Paderborn Germany Fax: (++49) 700 / Comments Suggestions Corrections manuals@fujitsu-siemens.com Submitted by Comments on PRIMERGY RX200 S2 D1790 Setup Utility A26361-D1790-Z

50

51 Information on this document On April 1, 2009, Fujitsu became the sole owner of Fujitsu Siemens Computers. This new subsidiary of Fujitsu has been renamed Fujitsu Technology Solutions. This document from the document archive refers to a product version which was released a considerable time ago or which is no longer marketed. Please note that all company references and copyrights in this document have been legally transferred to Fujitsu Technology Solutions. Contact and support addresses will now be offered by Fujitsu Technology Solutions and have the The Internet pages of Fujitsu Technology Solutions are available at and the user documentation at Copyright Fujitsu Technology Solutions, 2009 Hinweise zum vorliegenden Dokument Zum 1. April 2009 ist Fujitsu Siemens Computers in den alleinigen Besitz von Fujitsu übergegangen. Diese neue Tochtergesellschaft von Fujitsu trägt seitdem den Namen Fujitsu Technology Solutions. Das vorliegende Dokument aus dem Dokumentenarchiv bezieht sich auf eine bereits vor längerer Zeit freigegebene oder nicht mehr im Vertrieb befindliche Produktversion. Bitte beachten Sie, dass alle Firmenbezüge und Copyrights im vorliegenden Dokument rechtlich auf Fujitsu Technology Solutions übergegangen sind. Kontakt- und Supportadressen werden nun von Fujitsu Technology Solutions angeboten und haben die Die Internetseiten von Fujitsu Technology Solutions finden Sie unter und unter finden Sie die Benutzerdokumentation. Copyright Fujitsu Technology Solutions, 2009

The activities described in these upgrade instructions may only be performed by engineers or maintenance/technical staff.

The activities described in these upgrade instructions may only be performed by engineers or maintenance/technical staff. Introduction The upgrade instructions show how to remove the standard power supply and replace it with a hotplug power supply. The following steps only apply to the PRIMERGY 400 and 00 tower servers.!

More information

answers D1571 Setup Utility for RX100S2 Description English

answers D1571 Setup Utility for RX100S2 Description English answers 2 Description D1571 Setup Utility for RX100S2 English Dieses Handbuch wurde auf Recycling-Papier gedruckt. This manual has been printed on recycled paper. Ce manuel est imprimé sur du papier recyclé.

More information

PRIMERGY S40-DF Capacity Extension

PRIMERGY S40-DF Capacity Extension Server PRIMERGY S40-DF Capacity Extension Xenia Fierley Siemens Nixdorf Informationssysteme AG ICP CS PS QM 3 81730 München e-mail: email: manuals@fujitsu-siemens.com Tel.: (089) 636-47896 Fax: 0 700 /

More information

This symbol is followed by supplementary information, remarks and tips.

This symbol is followed by supplementary information, remarks and tips. Introduction This Technical Manual describes the system boards of the PRIMERGY 870 server systems, which can be equipped with up to four Intel Xeon processors. You may find further information in the description

More information

chipdisk for RemoteView

chipdisk for RemoteView PRIMERGY chipdisk for RemoteView Xenia Fierley Siemens Nixdorf Informationssysteme AG Primergy 81730 Munich e-mail: Internet:DOCetc@mchp.siemens.de Tel.: (089) 636-47896 Fax: (++ 49) 89 6 36-4 87 17 U41102-J-Z156-1-74

More information

Copyright (C) Fujitsu Siemens Computers GmbH 2005 All rights reserved

Copyright (C) Fujitsu Siemens Computers GmbH 2005 All rights reserved Fujitsu Siemens Computers GmbH DRV (BS2000/OSD) Version 3.1A November 2005 Release Notice Copyright (C) Fujitsu Siemens Computers GmbH 2005 All rights reserved Release Notice DRV V3.1A 1 General 2 1.1

More information

D2709 BIOS Setup Utility for PRIMERGY TX200 S5. Reference Manual

D2709 BIOS Setup Utility for PRIMERGY TX200 S5. Reference Manual D2709 BIOS Setup Utility for PRIMERGY TX200 S5 Reference Manual Edition May 2009 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your

More information

WebTransactions V7.1. Supplement

WebTransactions V7.1. Supplement WebTransactions V7.1 Supplement Edition: December 2006 This manual describes the new functions in WebTransactions V7.1. It is intended to supplement the WebTransactions V7.0 manuals. Comments Suggestions

More information

Copyright (C) Fujitsu Siemens Computers GmbH 2005 All rights reserved

Copyright (C) Fujitsu Siemens Computers GmbH 2005 All rights reserved Fujitsu Siemens Computers GmbH SM2-TOOLS (BS2000/OSD) Version 7.5A Juli 2006 Release Notice Copyright (C) Fujitsu Siemens Computers GmbH 2005 All rights reserved Release Notice SM2-TOOLS V7.5A 1 General

More information

FUJITSU SIEMENS COMPUTERS. Release Notice PCMX (LINUX-S390) V6.0A. Table of Contents

FUJITSU SIEMENS COMPUTERS. Release Notice PCMX (LINUX-S390) V6.0A. Table of Contents FUJITSU SIEMENS COMPUTERS Release Notice PCMX (LINUX-S390) V6.0A Table of Contents 1 General 1.1 Documentation 2 Notes on product use 2.1 Software/hardware configuration 2.1.1 Operating system 2.2 Resource

More information

D2786 BIOS Setup Utility for PRIMERGY RX200 S5. Reference Manual

D2786 BIOS Setup Utility for PRIMERGY RX200 S5. Reference Manual D2786 BIOS Setup Utility for PRIMERGY RX200 S5 Reference Manual Edition April 2009 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your

More information

R E L E A S E N O T I C E C O S M O S T O O L S V A. (c) Fujitsu Siemens Computers GmbH 2001

R E L E A S E N O T I C E C O S M O S T O O L S V A. (c) Fujitsu Siemens Computers GmbH 2001 R E L E A S E N O T I C E C O S M O S T O O L S V 1 4. 0 A (c) Fujitsu Siemens Computers GmbH 2001 Word and Excel are registered trademarks of Microsoft Postscript is a registered trademark of Adobe Contents

More information

Copyright (C) Fujitsu Siemens Computers GmbH 2008 All rights reserved

Copyright (C) Fujitsu Siemens Computers GmbH 2008 All rights reserved Fujitsu Siemens Computers GmbH XHCS-SYS (BS2000/OSD) Version 2.0A June 2008 Release Notice Copyright (C) Fujitsu Siemens Computers GmbH 2008 All rights reserved Release Notice XHCS-SYS V2.0A 1 General

More information

FibreCAT TXF Backup Subsystem. Service Supplement

FibreCAT TXF Backup Subsystem. Service Supplement FibreCAT TXF Backup Subsystem Service Supplement Edition October 2008 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps

More information

Copyright (C) Fujitsu Siemens Computers GmbH 2004 All rights reserved

Copyright (C) Fujitsu Siemens Computers GmbH 2004 All rights reserved Fujitsu Siemens Computers GmbH A I D Version 3.1 November 2004 Release Notice Copyright (C) Fujitsu Siemens Computers GmbH 2004 All rights reserved Release Notice AID V3.1 1 General....................

More information

D2863 BIOS Setup Utility for PRIMERGY RX100 S6. Reference Manual

D2863 BIOS Setup Utility for PRIMERGY RX100 S6. Reference Manual D2863 BIOS Setup Utility for PRIMERGY RX100 S6 Reference Manual Edition January 2010 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your

More information

Fujitsu Siemens Computers. internet Value Edition. Version 1.0B. July Release Notice

Fujitsu Siemens Computers. internet Value Edition. Version 1.0B. July Release Notice Fujitsu Siemens Computers internet Value Edition Version 1.0B July 2002 Release Notice Copyright (C) Fujitsu Siemens Computers 2002 All rights reserved Release Notice internet Value Edition V1.0B 1 General.....................

More information

BIOS Setup DESKPOWER 5000

BIOS Setup DESKPOWER 5000 BIOS Setup DESKPOWER 5000 1 Preface What is BIOS setup? BIOS setup is a program that helps the user set up a hardware environment, including memory, hard disks, and floppy disk drives. Minimum setup has

More information

T Series BIOS BIOS SETUP UTILITY

T Series BIOS BIOS SETUP UTILITY BIOS SECTION T4010 LifeBook T Series Tablet PC T Series BIOS BIOS SETUP UTILITY The BIOS Setup Utility is a program that sets up the operating environment for your tablet. Your BIOS is set at the factory

More information

Fujitsu LifeBook N Series

Fujitsu LifeBook N Series Fujitsu LifeBook N Series BIOS Guide LifeBook N Series Models: N6000 Document Date: 11/11/04 Document Part Number: FPC58-1268-01 F U J I T S U C O M P U T E R S Y S T E M S 1 LifeBook N Series Notebook

More information

BIOS Setup DESKPOWER 6000

BIOS Setup DESKPOWER 6000 BIOS Setup DESKPOWER 6000 1 Preface What is BIOS setup? BIOS setup is a program that helps the user set up a hardware environment, including memory, hard disks, and floppy disk drives. Minimum setup has

More information

Fujitsu LifeBook P Series

Fujitsu LifeBook P Series Fujitsu LifeBook P Series BIOS Guide LifeBook P Series Model: P1120 Document Date: 10/30/02 Document Part Number: FPC58-0796-01 FUJITSU PC CORPORATION LifeBook P Series Notebook BIOS P Series BIOS BIOS

More information

1. BIOS setup BIOS SETUP UTILITY. Critical Point

1. BIOS setup BIOS SETUP UTILITY. Critical Point BIOS SECTION P2040 1. BIOS setup BIOS SETUP UTILITY The BIOS Setup Utility is a program that sets up the operating environment for your notebook. Your BIOS is set at the factory for normal operating conditions,

More information

Fujitsu LifeBook T Series

Fujitsu LifeBook T Series Fujitsu LifeBook T Series BIOS Guide LifeBook T Series Model: T3010/T3010D Document Date: 09/16/03 Document Part Number: FPC58-0992-01 FUJITSU PC CORPORATION 1 LifeBook T Series Tablet PC T Series BIOS

More information

S Series BIOS BIOS SETUP UTILITY. Entering the BIOS Setup Utility. Entering the Setup Utility After a Configuration Change or System Failure

S Series BIOS BIOS SETUP UTILITY. Entering the BIOS Setup Utility. Entering the Setup Utility After a Configuration Change or System Failure BIOS SECTION S6130 LifeBook S Series Notebook BIOS S Series BIOS BIOS SETUP UTILITY The BIOS Setup Utility is a program that sets up the operating environment for your notebook. Your BIOS is set at the

More information

S Series BIOS BIOS SETUP UTILITY

S Series BIOS BIOS SETUP UTILITY BIOS SECTION S2110 LifeBook S Series Notebook BIOS S Series BIOS BIOS SETUP UTILITY The BIOS Setup Utility is a program that sets up the operating environment for your notebook. Your BIOS is set at the

More information

Fujitsu LifeBook S Series

Fujitsu LifeBook S Series Fujitsu LifeBook S Series BIOS Guide LifeBook S Series Model: S2020 Document Date: 10/30/03 Document Part Number: FPC58-1035-01 FUJITSU COMPUTER SYSTEMS 1 LifeBook S Series Notebook BIOS S Series BIOS

More information

S Series BIOS BIOS SETUP UTILITY. Entering the BIOS Setup Utility. Entering the Setup Utility After a Configuration Change or System Failure

S Series BIOS BIOS SETUP UTILITY. Entering the BIOS Setup Utility. Entering the Setup Utility After a Configuration Change or System Failure BIOS SECTION S7010 LifeBook S Series Notebook BIOS S Series BIOS BIOS SETUP UTILITY The BIOS Setup Utility is a program that sets up the operating environment for your notebook. Your BIOS is set at the

More information

Using Egenera Virtualized Boot Services

Using Egenera Virtualized Boot Services Using Egenera Virtualized Boot Services For BladeFrame BF400 S2 and BladeFrame BF200 Document Number 432-SB0045 September 2008 EVBS1.0_BF_1 Copyright Copyright 2008 Egenera, Inc. All rights reserved. This

More information

Streamer DAT160 Half-Height 80GB/160GB, USB 2.0

Streamer DAT160 Half-Height 80GB/160GB, USB 2.0 User Guide English Streamer DAT160 Half-Height 80GB/160GB, USB 2.0 Streamer DAT160 Half-Height 80GB/160GB, USB 2.0 User Guide Edition November 2008 Comments Suggestions Corrections The User Documentation

More information

PRIMERGY BX600 10GbE LAN I/O Module (PCIe)

PRIMERGY BX600 10GbE LAN I/O Module (PCIe) Reference Guide PRIMERGY BX600 10GbE LAN I/O Module (PCIe) Microsoft Windows Server 2003 iscsiselect Reference Guide English PRIMERGY BX600 10GbE LAN I/O Module (PCIe) Microsoft Windows Server 2003 iscsiselect

More information

BIOS SECTION S6210/6220

BIOS SECTION S6210/6220 BIOS SECTION S6210/6220 LifeBook S Series Notebook BIOS S Series BIOS BIOS SETUP UTILITY The BIOS Setup Utility is a program that sets up the operating environment for your notebook. Your BIOS is set at

More information

Fujitsu LifeBook P Series

Fujitsu LifeBook P Series Fujitsu LifeBook P Series BIOS Guide LifeBook P Series Model: P-1032 P-1035 Document Date: 02/01/02 Document Part Number: FPC58-0653-01 FUJITSU PC CORPORATION LifeBook P Series BIOS P Series BIOS BIOS

More information

Fujitsu LifeBook E Series

Fujitsu LifeBook E Series Fujitsu LifeBook E Series BIOS Guide LifeBook E Series Models: E2010 Document Date: 02/05/03 Document Part Number: FPC58-0881-01 F U J I T S U P C C O R P O R A T I O N 1 LifeBook E Series BIOS E Series

More information

1. S Series BIOS BIOS SETUP UTILITY

1. S Series BIOS BIOS SETUP UTILITY BIOS SECTION S6010 1. S Series BIOS BIOS SETUP UTILITY The BIOS Setup Utility is a program that sets up the operating environment for your notebook. Your BIOS is set at the factory for normal operating

More information

Fujitsu LifeBook P Series

Fujitsu LifeBook P Series Fujitsu LifeBook P Series BIOS Guide LifeBook P Series Model: P7120/P7120D Document Date: 11/3/2005 Document Part Number: FPC58-1425-01 FUJITSU COMPUTER SYSTEMS CORPORATION LifeBook P7000 Notebook BIOS

More information

Emanate Master 1.3. Readme. Edition June 2000

Emanate Master 1.3. Readme. Edition June 2000 Solaris Emanate Master 1.3 Readme Redakteur Fujitsu Siemens Computers GmbH Paderborn 33094 Paderborn e-mail: email: manuals@fujitsu-siemens.com Tel.: (089) 636-00000 Fax: (++49) 700 / 372 00001 Bestellnummer

More information

Copyright (C) Fujitsu Siemens Computers GmbH 2005 *3 All rights reserved *3

Copyright (C) Fujitsu Siemens Computers GmbH 2005 *3 All rights reserved *3 Fujitsu Siemens Computers GmbH CRTE (BS2000/OSD) Version 2.4C *4 October 2005 *4 Release Notice Copyright (C) Fujitsu Siemens Computers GmbH 2005 *3 All rights reserved *3 Release Notice CRTE V2.4C 1 General.....................

More information

E Series BIOS BIOS SETUP UTILITY. Entering the BIOS Setup Utility. Entering the Setup Utility After a Configuration Change or System Failure

E Series BIOS BIOS SETUP UTILITY. Entering the BIOS Setup Utility. Entering the Setup Utility After a Configuration Change or System Failure BIOS SECTION E8020 LifeBook E Series BIOS E Series BIOS BIOS SETUP UTILITY The BIOS Setup Utility is a program that sets up the operating environment for your notebook. Your BIOS is set at the factory

More information

Fujitsu LifeBook B Series

Fujitsu LifeBook B Series Fujitsu LifeBook B Series BIOS Guide LifeBook B Series Model: B2620 Document Date: 10/30/02 Document Part Number: FPC58-0792-01 FUJITSU PC CORPORATION LifeBook B Series Notebook BIOS B Series BIOS BIOS

More information

Fujitsu LifeBook A Series

Fujitsu LifeBook A Series Fujitsu LifeBook A Series BIOS Guide LifeBook A Series Model: A6030 Document Date: 06/06/2007 Document Part Number: FPC58-1698-01 FUJITSU COMPUTER SYSTEMS CORPORATION 1 LifeBook A Series BIOS A Series

More information

LifeBook P Series Notebook BIOS

LifeBook P Series Notebook BIOS BIOS SECTION P1610 LifeBook P1600 Notebook BIOS LifeBook P Series Notebook BIOS BIOS SETUP UTILITY The BIOS Setup Utility is a program that sets up the operating environment for your notebook. Your BIOS

More information

Fujitsu LifeBook P Series

Fujitsu LifeBook P Series Fujitsu LifeBook P Series BIOS Guide LifeBook P Series Model: P1620 Document Date: 1/29/2008 Document Part Number: FPC58-1817-01 FUJITSU COMPUTER SYSTEMS CORPORATION LifeBook P1600 Notebook BIOS LifeBook

More information

Fujitsu LifeBook A Series

Fujitsu LifeBook A Series Fujitsu LifeBook A Series BIOS Guide LifeBook A Series Models: A3040 Document Date: 2/10/06 Document Part Number: FPC58-1482-01 F U J I T S U C O M P U T E R S Y S T E M S 1 LifeBook A Series Notebook

More information

Fujitsu LifeBook N Series

Fujitsu LifeBook N Series Fujitsu LifeBook N Series BIOS Guide LifeBook N Series Models: N6400 Document Date: 07/16/2007 Document Part Number: FPC58-1702-01 FUJITSU COMPUTER SYSTEMS CORPORATION 1 LifeBook N Series BIOS N Series

More information

Fujitsu LifeBook T Series

Fujitsu LifeBook T Series Fujitsu LifeBook T Series BIOS Guide LifeBook T Series Model: T4020/T4020D Document Date: 08/08/2005 Document Part Number: FPC58-1407-01 FUJITSU COMPUTER SYSTEMS 1 LifeBook T Series Tablet PC T Series

More information

Fujitsu Stylistic ST6000 Series

Fujitsu Stylistic ST6000 Series Fujitsu Stylistic ST6000 Series BIOS Guide Stylistic Series Model: ST6012 Document Date: 12/01/2008 Document Part Number: FPC65-4369-01 FUJITSU COMPUTER SYSTEMS CORPORATION 1 Stylistic ST Series BIOS ST

More information

answers D1751 / 1755 Setup Utility for TX150 S2 / Econel 40 Preliminary Description English

answers D1751 / 1755 Setup Utility for TX150 S2 / Econel 40 Preliminary Description English answers 2 Description D1751 / 1755 Setup Utility for TX150 S2 / Econel 40 Preliminary English Dieses Handbuch wurde auf Recycling-Papier gedruckt. This manual has been printed on recycled paper. Ce manuel

More information

1/6. Main. Bios Version System Time System Date Hide Diagnostic Messages During Enabled Disabled POST Error Pause. Processor.

1/6. Main. Bios Version System Time System Date Hide Diagnostic Messages During Enabled Disabled POST Error Pause. Processor. 2006 3 Main ( ) Bios Version BIOS System Time System Date Hide Diagnostic Messages During Enabled Disabled POST Error Pause Enabled Disabled Processor ( ) Core Frequency CPU Bus Frequency CPU FSB Processor

More information

PRIMERGY Econel 200 S2 Server

PRIMERGY Econel 200 S2 Server PRIMERGY PRIMERGY Econel 200 S2 Server Options Guide Susanne Däschlein Fujitsu Siemens Computers GmbH München 81730 Munich e-mail: email: manuals@fujitsu-siemens.com Tel.: (089) 61001-155 Fax: (++49) 700

More information

Phoenix BIOS Setup Utility

Phoenix BIOS Setup Utility Phoenix BIOS Setup Utility Important information: we continually strive to bring you the latest and proven features and technologies. As part of our drive to continually improve our products modifications

More information

S Series BIOS BIOS SETUP UTILITY

S Series BIOS BIOS SETUP UTILITY BIOS SECTION S7020 LifeBook S Series Notebook BIOS S Series BIOS BIOS SETUP UTILITY The BIOS Setup Utility is a program that sets up the operating environment for your notebook. Your BIOS is set at the

More information

Reference Manual. BIOS Setup V4.06. English

Reference Manual. BIOS Setup V4.06. English 2 Reference Manual BIOS Setup V4.06 English Dieses Handbuch wurde auf Recycling-Papier gedruckt. This manual has been printed on recycled paper. Ce manuel est imprimé sur du papier recyclé. Este manual

More information

System board D2020 for Econel 200

System board D2020 for Econel 200 Produktfamilie System board D2020 for Econel 200 Technical manual Redakteur Fujitsu Siemens Computers GmbH München 81730 Munich e-mail: email: manuals@fujitsu-siemens.com Tel.: (089) 61001-??? Fax: (++49)

More information

PRIMERGY TX200 S3 Server

PRIMERGY TX200 S3 Server PRIMERGY PRIMERGY TX200 S3 Server Service Supplement Susanne Däschlein Fujitsu Siemens Computers GmbH München 81730 München e-mail: email: manuals@fujitsu-siemens.com Tel.: (089) 61001155 Fax: (++49) 700

More information

Fujitsu LifeBook S Series

Fujitsu LifeBook S Series Fujitsu LifeBook S Series BIOS Guide LifeBook S Series Model: S-4572 F U J I T S U P C C O R P O R A T I O N FPC58-0547-01 LifeBook S Series BIOS S Series BIOS BIOS SETUP UTILITY The BIOS Setup Utility

More information

Fujitsu LifeBook P Series

Fujitsu LifeBook P Series Fujitsu LifeBook P Series BIOS Guide LifeBook P Series Model: P8010 Document Date: 01/31/2008 Document Part Number: FPC58-1819-01 FUJITSU COMPUTER SYSTEMS CORPORATION 1 LifeBook P Series BIOS P Series

More information

PRIMERGY Econel 100 Server System

PRIMERGY Econel 100 Server System PRIMERGY PRIMERGY Econel 100 Server System Service Supplement Susanne Däschlein Fujitsu Siemens Computers GmbH München 81730 München e-mail: email: manuals@fujitsu-siemens.com Tel.: (0 89) 61 001-155 Fax:

More information

System Board D2619 for RX/TX300 S5. Technical Manual

System Board D2619 for RX/TX300 S5. Technical Manual System Board D2619 for RX/TX300 S5 Technical Manual Edition April 2009 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps

More information

Fujitsu LifeBook B Series

Fujitsu LifeBook B Series Fujitsu LifeBook B Series BIOS Guide LifeBook B Series Model: B6210 Document Date: 06/12/2006 Document Part Number: FPC58-1519-01 FUJITSU COMPUTER SYSTEMS LifeBook B Series Notebook BIOS B Series BIOS

More information

Fujitsu LifeBook E Series

Fujitsu LifeBook E Series Fujitsu LifeBook E Series BIOS Guide LifeBook E Series Model: E8110 (Vista OS) Document Date: 03/30/2007 Document Part Number: FPC58-1643-01 FUJITSU COMPUTER SYSTEMS CORPORATION 1 LifeBook E Series BIOS

More information

The MTC Autoloader FibreCAT TX24 - Use with OSD/XC at SX Servers -

The MTC Autoloader FibreCAT TX24 - Use with OSD/XC at SX Servers - The MTC Autoloader FibreCAT TX24 - Use with OSD/XC at SX Servers - Readme File Contents 1 Introduction...2 2 Characteristics...4 2.1 General Characteristics...4 2.2 Release with OSD/XC...4 2.3 Hardware,

More information

Fujitsu LifeBook U Series

Fujitsu LifeBook U Series Fujitsu LifeBook U Series BIOS Guide LifeBook U Series Model: UH900 Document Date: 01/07/2010 Document Part Number: FPC58-2547-01 FUJITSU AMERICA, INC. 1 LifeBook U Series BIOS U Series BIOS BIOS SETUP

More information

Fujitsu LifeBook E Series

Fujitsu LifeBook E Series Fujitsu LifeBook E Series BIOS Guide LifeBook E Series Model: E8410 Document Date: 05/25/2007 Document Part Number: FPC58-1690-01 FUJITSU COMPUTER SYSTEMS CORPORATION 1 LifeBook E Series BIOS E Series

More information

Fujitsu LifeBook A Series

Fujitsu LifeBook A Series Fujitsu LifeBook A Series BIOS Guide LifeBook A Series Model: AH530 Document Date: 06/09/2010 Document Part Number: FPC58-2714-01 FUJITSU AMERICA, INC. 1 LifeBook PH520 BIOS A Series BIOS BIOS SETUP UTILITY

More information

Express5800 ES1400 System Release Notes

Express5800 ES1400 System Release Notes System Release Notes Express5800 ES1400 System Release Notes PN: 904482-02 Proprietary Notice and Liability Disclaimer The information disclosed in this document, including all designs and related materials,

More information

Fujitsu LifeBook N Series

Fujitsu LifeBook N Series Fujitsu LifeBook N Series BIOS Guide LifeBook N Series Models: NH570 Document Date: 02/01/2010 Document Part Number: FPC58-2649-01 FUJITSU AMERICA, INC. 1 LifeBook N Series BIOS N Series BIOS BIOS SETUP

More information

Fujitsu LifeBook C Series

Fujitsu LifeBook C Series Fujitsu LifeBook C Series BIOS Guide LifeBook C Series Model: C1320D Document Date: 09/06/2005 Document Part Number: FPC58-1401-01 FUJITSU COMPUTER SYSTEMS LifeBook C Series Notebook BIOS C Series BIOS

More information

Fujitsu LifeBook T Series

Fujitsu LifeBook T Series Fujitsu LifeBook T Series BIOS Guide LifeBook T Series Model: T580 Document Date: 12/10/2010 Document Part Number: FPC58-2801-01 FUJITSU AMERICA, INCORPORATED 1 LIFEBOOK T580 BIOS T Series BIOS BIOS SETUP

More information

Fujitsu LifeBook B Series

Fujitsu LifeBook B Series Fujitsu LifeBook B Series BIOS Guide LifeBook B Series Model: B6230 Document Date: 02/05/2008 Document Part Number: FPC58-1827-01 FUJITSU COMPUTER SYSTEMS CORPORATION LifeBook B6200 Notebook BIOS LifeBook

More information

PRIMERGY Econel 100 Server System

PRIMERGY Econel 100 Server System PRIMERGY PRIMERGY Econel 100 Server System Options Guide Susanne Däschlein Fujitsu Siemens Computers GmbH München 81730 Munich e-mail: email: manuals@fujitsu-siemens.com Tel.: (0 89) 61 001-155 Fax: (++49)

More information

System Board D2559 for TX150 S6. Technical Manual

System Board D2559 for TX150 S6. Technical Manual System Board D2559 for TX150 S6 Technical Manual Edition November 2007 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps

More information

A Series BIOS BIOS SETUP UTILITY

A Series BIOS BIOS SETUP UTILITY BIOS SECTION A3110 LifeBook A Series BIOS A Series BIOS BIOS SETUP UTILITY The is a program that sets up the operating environment for your notebook. Your BIOS is set at the factory for normal operating

More information

PRIMERGY RX100 S3 Server System

PRIMERGY RX100 S3 Server System PRIMERGY PRIMERGY RX100 S3 Server System Options Guide Susanne Däschlein Fujitsu Siemens Computers GmbH München 81730 München e-mail: email: manuals@fujitsu-siemens.com Tel.: (089) 61001155 Fax: (++49)

More information

System board D2004 for RX100 S3

System board D2004 for RX100 S3 PRIMERGY System board D2004 for RX100 S3 Technical manual Däschlein Fujitsu Siemens Computers GmbH München 81730 Munich e-mail: email: manuals@fujitsu-siemens.com Tel.: (089) 61001-155 Fax: (++49) 700

More information

LAN Manager/X V2.2. (SINIX) SNMP Service. System Administator's Guide

LAN Manager/X V2.2. (SINIX) SNMP Service. System Administator's Guide LAN Manager/X V2.2 (SINIX) SNMP Service System Administator's Guide Is there anything you want to tell us about this manual? Please send us your comments, quoting the order number of the manual. Siemens

More information

Fujitsu LifeBook A Series

Fujitsu LifeBook A Series Fujitsu LifeBook A Series BIOS Guide LifeBook A Series Model: A3130 Document Date: 06/20/2007 Document Part Number: FPC58-1706-01 FUJITSU COMPUTER SYSTEMS CORPORATION 1 LifeBook A Series BIOS A Series

More information

Fujitsu LifeBook S Series

Fujitsu LifeBook S Series Fujitsu LifeBook S Series BIOS Guide LifeBook S Series Model: S2210 - Vista Document Date: 01/30/2007 Document Part Number: FPC58-1655-01 FUJITSU COMPUTER SYSTEMS CORPORATION 1 LifeBook S Series Notebook

More information

Fujitsu LifeBook A & V Series

Fujitsu LifeBook A & V Series Fujitsu LifeBook A & V Series BIOS Guide LifeBook A & V Series Models: A1110/A1120 V1030 Document Date: 10/01/2008 Document Part Number: FPC65-4363-01 FUJITSU COMPUTER SYSTEMS CORPORATION 1 LifeBook A1110/V1030

More information

Computer Setup (F10) Utility Guide HP Business Desktops dx5150 model

Computer Setup (F10) Utility Guide HP Business Desktops dx5150 model Guide HP Business Desktops dx5150 model Document Part Number: 374172-001 December 2004 This guide provides instructions on how to use Computer Setup. This tool is used to reconfigure and modify computer

More information

PRIMERGY RX800 S2/S3 RemoteView Management Board RSA-II

PRIMERGY RX800 S2/S3 RemoteView Management Board RSA-II Produktfamilie PRIMERGY RX800 S2/S3 RemoteView Management Board RSA-II User Manual Joachim Pichol Fujitsu Siemens Computers GmbH Paderborn 33094 Paderborn e-mail: email: manuals@fujitsu-siemens.com Tel.:

More information

Fujitsu LifeBook T Series

Fujitsu LifeBook T Series Fujitsu LifeBook T Series BIOS Guide LifeBook T Series Model: T1010 with UMTS Document Date: 01/15/2009 Document Part Number: FPC58-2038-01 FUJITSU COMPUTER SYSTEMS CORPORATION 1 LifeBook T Series BIOS

More information

PRIMERGY RX200 S3 Server. Options Guide

PRIMERGY RX200 S3 Server. Options Guide PRIMERGY RX200 S3 Server Options Guide Edition August 2006 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps us optimize

More information

Fujitsu LifeBook P Series

Fujitsu LifeBook P Series Fujitsu LifeBook P Series BIOS Guide LifeBook P Series Model: P771 Document Date: 2/18/2011 Document Part Number: FPC58-2855-01 FUJITSU AMERICA, INCORPORATED 1 LIFEBOOK P771 BIOS P Series BIOS BIOS SETUP

More information

PRIMERGY TX150 S5 Server

PRIMERGY TX150 S5 Server PRIMERGY PRIMERGY TX150 S5 Server Service Supplement Susanne Däschlein Fujitsu Siemens Computers GmbH München 81730 München e-mail: email: manuals@fujitsu-siemens.com Tel.: (089) 61001155 Fax: (++49) 700

More information

Fujitsu LifeBook E Series

Fujitsu LifeBook E Series Fujitsu LifeBook E Series BIOS Guide LifeBook E Series Model: E8420 Document Date: 07/10/2008 Document Part Number: FPC58-1911-01 FUJITSU COMPUTER SYSTEMS CORPORATION 1 LifeBook E Series BIOS E Series

More information

Fujitsu LifeBook T Series

Fujitsu LifeBook T Series Fujitsu LifeBook T Series BIOS Guide LifeBook T Series Model: T5010 - UMTS Model Document Date: 02/18/2009 Document Part Number: FPC58-2036-01 FUJITSU COMPUTER SYSTEMS CORPORATION 1 LifeBook T Series BIOS

More information

Chapter 4 Using BIOS 1

Chapter 4 Using BIOS 1 Chapter 1 Using BIOS 4 4.1 About the Setup Utility The computer uses the latest American Megatrends Inc. BIOS with support for Windows Plug and Play. The CMOS chip on the motherboard contains the ROM setup

More information

PAN Manager Feature Summary

PAN Manager Feature Summary PAN Manager Feature Summary For BladeFrame BF400 S2 and BladeFrame BF200 Document Number 430-SB0073 August 2008 PM5.2_BF Copyright Copyright 2008 Egenera, Inc. All rights reserved. This document, and the

More information

D2799 BIOS Setup Utility for PRIMERGY TX200 S6

D2799 BIOS Setup Utility for PRIMERGY TX200 S6 Reference Manual - Englisch D2799 BIOS Setup Utility for PRIMERGY TX200 S6 Reference Manual Edition July 2010 Comments Suggestions Corrections The User Documentation Department would like to know your

More information

Fujitsu LifeBook T Series

Fujitsu LifeBook T Series Fujitsu LifeBook T Series BIOS Guide LifeBook T Series Models: T900 Document Date: 02/03/2010 Document Part Number: FPC58-2643-01 FUJITSU AMERICA, INCORPORATED 1 LifeBook T Series BIOS T Series BIOS BIOS

More information

System Board D2785 for TX120 S2. Technical Manual

System Board D2785 for TX120 S2. Technical Manual System Board D2785 for TX120 S2 Technical Manual Edition April 2009 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps

More information

PRIMERGY BX630 Scalable Server Blade

PRIMERGY BX630 Scalable Server Blade PRIMERGY PRIMERGY BX630 Scalable Server Blade Service Supplement Redakteur Fujitsu Siemens Computers GmbH Paderborn 33094 Paderborn e-mail: email: manuals@fujitsu-siemens.com Tel.: (089) 61001-??? Fax:

More information

This chapter tells how to configure the system by setting the BIOS parameters. 3.1 Entering the AMI BIOS Setup

This chapter tells how to configure the system by setting the BIOS parameters. 3.1 Entering the AMI BIOS Setup Chapter 3 AMI BIOS This chapter tells how to configure the system by setting the BIOS parameters. 3.1 Entering the AMI BIOS Setup To enter the AMI BIOS Setup, press appears as shown below.. The AMI BIOS

More information

N Series BIOS BIOS SETUP UTILITY

N Series BIOS BIOS SETUP UTILITY BIOS SECTION N3530 LifeBook N Series Notebook BIOS N Series BIOS BIOS SETUP UTILITY The BIOS Setup Utility is a program that sets up the operating environment for your notebook. Your BIOS is set at the

More information

PRIMERGY 670 Converting Guide

PRIMERGY 670 Converting Guide PRIMERGY 670 Converting Guide Server Systems A26361-K531-Z101-1-7419 Edition March 1999 Copyright and Trademarks Intel and Pentium are registered trademarks of Intel Corporation, USA. NetWare and Novell

More information

B I O S S E C T I O N B

B I O S S E C T I O N B BIO ECTION B2174 1. BIO setup napshots of the BIO setup screen and the possible setup options is shown in the following sections. Underlined setup options show the default settings. Columns between elections

More information

Computer Setup (F10) Utility Guide Business PCs

Computer Setup (F10) Utility Guide Business PCs Guide Business PCs Document Part Number: 361206-004 November 2005 This guide provides instructions on how to use Computer Setup. This tool is used to reconfigure and modify computer default settings when

More information

Reference Manual. Setup Utility D1350

Reference Manual. Setup Utility D1350 Reference Manual Setup Utility D1350 Dieses Handbuch wurde auf Recycling-Papier gedruckt. This manual has been printed on recycled paper. Ce manuel est imprimé sur du papier recyclé. Este manual ha sido

More information

STREAMER VXA /320 GB

STREAMER VXA /320 GB Operating Manual English STREAMER VXA-320 160/320 GB Are there...... any technical problems or other questions you need clarified? Please contact our Help Desk (see warranty card). The latest information

More information