1 Server PRIMERGY S40-DF Capacity Extension Xenia Fierley Siemens Nixdorf Informationssysteme AG ICP CS PS QM München manuals@fujitsu-siemens.com Tel.: (089) Fax: / U41100-J-Z Sprachen: En Edition May 2001
2 Comments Suggestions Corrections The User Documentation Department would like to know your opinion on this manual. Your feedback helps us to optimize our documentation to suit your individual needs. Fax forms for sending us your comments are included at the back of the manual. There you will also find the addresses of the relevant User Documentation Department Copyright and Trademarks Copyright 2001 Fujitsu Siemens Computers GmbH. All rights reserved. Delivery subject to availability; right of technical modifications reserved. All hardware and software names used are trademarks of their respective manufacturers. This manual was produced by cognitas. Gesellschaft für Technik-Dokumentation mbh This manual is printed on paper treated with chlorine-free bleach.
3 German English
4
5 Contents 1 PRIMERGY S40-DF capacity extension Target group Notational conventions Important notes Notes on safety ESD label Notes on transportation Converting the PRIMERGY S40-DF Removing and mounting the door Removing and mounting the side or top cover Removing and mounting the protective shield Converting the internal configuration Installing the LVD extender board Connecting the capacity extension Related publications Index U41100-J-Z
6
7 1 PRIMERGY S40-DF capacity extension The PRIMERGY S40-DF is the active component in the PRIMERGY S40 family of storage subsystems. The integrated disk array controller allows you to extend storage capacity using additional externally-connected passive PRIMERGY S40-ES storage devices. Two of these so-called daisy-chain configurations, i.e., with one or three PRIMERGY S40-ES units, are supported (see also the chapter on Configurations in the PRIMERGY S40-DF Operating Manual). In order to use a configuration with three external PRIMERGY S40-ES units, you will need the 1-channel version of the PRIMERGY S40-DF. This manual contains conversion instructions which describe the steps required to prepare a PRIMERGY S40-DF (3-channel version) for capacity expansion with three PRIMERGY S40-ES subsystems. For more assistance in understanding the details here, see also the operating instructions for the PRIMERGY S40-DF Storage Subsystem. Further relevant information can be found in the manual Safety, Warranty and Ergonomy (see section Related publications on page 21). U41100-J-Z
8 Target group PRIMERGY S40-DF capacity extension 1.1 Target group These conversion instructions are intended for those who are responsible for installing hardware and for ensuring that the system runs smoothly (service personnel, technicians and technical specialists). You will therefore need to be familiar with the hardware and data transmission concepts to understand the various activities described. 1.2 Notational conventions bold type quotation marks V CAUTION! I Used for emphasis in the body of the text Used for references to other chapters, sections or manuals Identifies an action that you need to take Indicates a warning which, if not observed, could jeopardize your health or the proper functionality of the system Indicates additional information, notes and tips Table 1: Notational conventions 2 U41100-J-Z
9 PRIMERGY S40-DF capacity extension Important notes 1.3 Important notes Notes on safety Please observe all the safety instructions given in the documentation of the PRIMERGY S40-DF as well as the following notes: V CAUTION! The actions described here should only be performed by technicians, service personnel or technical specialists. Any failure to observe the guidelines in this manual could expose the user to considerable risks (electric shock, fire hazards) and could also damage the equipment. Note that any unauthorized opening of the device will result in the invalidation of the warranty and exclusion from all liability. Make sure that no objects (such as bracelets or paper clips) or liquids fall into the device, as this may result in an electric shock or a short circuit. Before opening the unit, switch off the device and then pull out the power plugs. Note that switching off the device does not disconnect it from the power supply. To ensure that the device is fully disconnected from the power supply, you must pull out the power plugs ESD label Systems and components which might be damaged by electrostatic discharge (ESD) may be marked with the following label: Figure 1: Label indicating ESD-sensitive devices U41100-J-Z
10 Important notes PRIMERGY S40-DF capacity extension When handling ESD-sensitive devices, it is essential that you observe the following guidelines: You must electrostatically discharge yourself (e.g. by touching a grounded object) before handling such components. Any devices or tools that are used must be free from electrostatic charge. Pull out the power plug before mounting or dismounting ESD-sensitive devices. ESD-sensitive devices should only be held at the edges. Do not touch any pins, connectors or circuits on an ESD-sensitive device. When installing boards, make sure that you use an electrostatic wrist-band or some other suitable grounding cable that connects you to the external housing of the system unit. Place all components on a pad which is free from electrostatic charge. I For detailed instructions on handling ESD-sensitive modules, please read the German documentation Richtlinie zur Handhabung von elektrostatisch gefährdeten Bauelementen und Baugruppen (EGB)" or ITS-Rundschreiben Nr. 4/95". I An ESD kit can be ordered from SIEMENS sales or an authorized distributor under the order number 8501 and stock-no Notes on transportation I The storage subsystem should always be transported only in its original packaging or in some other suitable packaging that protects it against shock or impact. It should only be unpacked at the deployment site. If you need to physically lift or transport the storage subsystem, ask someone to assist you. 4 U41100-J-Z
11 PRIMERGY S40-DF capacity extension Converting the PRIMERGY S40-DF 1.4 Converting the PRIMERGY S40-DF In order to install expanded storage capacity using one or three PRIMERGY S40-ES storage subsystems, you will need the corresponding conversion kit. This conversion kit contains the following components: an LVD extender board (3-channel version and 1-channel version) an OLR/STM-LVD flat ribbon cable (3-channel version) Proceed as follows: Unpack all the components. Check the contents of the package for any visible damage resulting from transportation. Verify that the delivered components match those listed in the delivery note. If you detect any damage resulting from transportation or any deviations in the supplied contents and the delivery note, please contact your vendor immediately! Floorstand and stackable models Make sure that the storage subsystem is freely accessible from the front and the back. Switch off the storage subsystem and disconnect it from the power supply. V CAUTION! Note that switching off the device does not disconnect it from the power supply. To ensure that the device is fully disconnected from the power supply, you must pull out the power plugs. Remove the door (see section Removing and mounting the door on page 8). Remove the left side cover for the floorstand model or the top cover for the stackable model (see section Removing and mounting the side or top cover on page 9). Remove the protective shield for the SCSI area of the storage subsystem (see section Removing and mounting the protective shield on page 10). U41100-J-Z
12 Converting the PRIMERGY S40-DF PRIMERGY S40-DF capacity extension Convert the internal configuration of the storage subsystem from a 3-channel configuration to a 1-channel configuration (see section Converting the internal configuration on page 11). Mount the protective shield for the SCSI area (see section Removing and mounting the protective shield on page 10). Replace the side or top cover (see section Removing and mounting the side or top cover on page 9). Replace the door and close the storage subsystem (see section Removing and mounting the door on page 8). Install the LVD extender board (see section Installing the LVD extender board on page 17). Connect the three PRIMERGY S40-ES units to the corresponding SCSI ports on the LVD extender board (see section Connecting the capacity extension on page 19). I Note that if the PRIMERGY S40-ES is connected, the system parameters PWR ON/OFF BY BUTTON and PWR ON/OFF BY CAN must be set to DISABLE. Connect the PRIMERGY S40-DF and the three PRIMERGY S40-ES units to the power supply. Connect the PRIMERGY S40-DF to the PRIMERGY server. Rack model Make sure that the storage subsystem is freely accessible from the front and the back. Switch off the storage subsystem and disconnect it from the power supply. V CAUTION! Note that switching off the device does not disconnect it from the power supply. To ensure that the device is fully disconnected from the power supply, you must pull out the power plugs. Loosen the four knurled screws and pull out the storage subsystem from the rack. 6 U41100-J-Z
13 PRIMERGY S40-DF capacity extension Converting the PRIMERGY S40-DF Remove the rack storage subsystem from the rack. V CAUTION! For removing the device from the rack, ask someone to assist you. For more assistance, see the operating instructions for the PRIMERGY S40-DF Storage Subsystem (see section Related publications on page 21). Remove the protective shield for the SCSI area of the storage subsystem (see section Removing and mounting the protective shield on page 10). Convert the internal configuration of the storage subsystem from a 3-channel configuration to a 1-channel configuration (see section Converting the internal configuration on page 11). Mount the protective shield for the SCSI area (see section Removing and mounting the protective shield on page 10). Insert the storage subsystem back in the rack and fasten it with the four knurled screws. Install the LVD extender board (see section Installing the LVD extender board on page 17). Install the three PRIMERGY S40-ES units in the rack with the help of the operating instructions for the PRIMERGY S40-BS/-ES Storage Subsystem. Connect the three PRIMERGY S40-ES units to the corresponding SCSI ports on the LVD extender board (see section Connecting the capacity extension on page 19). I Note that if the PRIMERGY S40-ES is connected, the system parameters PWR ON/OFF BY BUTTON and PWR ON/OFF BY CAN must be set to DISABLE. Connect the PRIMERGY S40-DF and the three PRIMERGY S40-ES units to the power supply. Connect the PRIMERGY S40-DF to the PRIMERGY server. U41100-J-Z
14 Converting the PRIMERGY S40-DF PRIMERGY S40-DF capacity extension Removing and mounting the door I Since the same method applies to both the floorstand and stackable models, only the floorstand model is shown in the following figure.! Figure 2: Removing the door (floorstand model) Unlock the door with the key (1) and open it (2). Remove the door by lifting it up (3) and out. Mounting is performed in the reverse order. 8 U41100-J-Z
15 PRIMERGY S40-DF capacity extension Converting the PRIMERGY S40-DF Removing and mounting the side or top cover Figure 3: Removing the side cover (floorstand model) Figure 4: Removing the top cover (stackable model) Press the two buttons (1) and remove the left side cover or the top cover (2). Mounting is performed in the reverse order. U41100-J-Z
16 Converting the PRIMERGY S40-DF PRIMERGY S40-DF capacity extension Removing and mounting the protective shield I Since the same method applies to all housing models, only the rack-mounted model is shown in the following figures. Figure 5: Unlocking the protective shield Unlock the protective shield for the SCSI area by turning the lever (figure 5) and remove the protective shield (figure 6). Figure 6: Removing the protective shield 10 U41100-J-Z
17 PRIMERGY S40-DF capacity extension Converting the PRIMERGY S40-DF Mounting is performed in the reverse order. For mounting, the four metal tabs (1) must first be inserted into the corresponding openings (2) (see figure 7). Figure 7: Mounting the protective shield Converting the internal configuration V CAUTION! The actions described here should only be performed by technicians, service personnel or technical specialists. Any failure to observe the guidelines in this manual could expose the user to considerable risks (electric shock, fire hazards) and could also damage the equipment. Note that any unauthorized opening of the device will result in the invalidation of the warranty and exclusion from all liability. In order to install a capacity expansion with three PRIMERGY S40-ES units, you will need to first change the internal cabling of the PRIMERGY S40-DF from a 3-channel configuration (figure 8 on page 12) to a 1-channel configuration (figure 12 on page 16). The same method applies to all housing models. U41100-J-Z
18 ! " Converting the PRIMERGY S40-DF PRIMERGY S40-DF capacity extension > =? F = A I? = C A!? = C A? = C A 5 6 K A 5 6 K A 5 6 K A!!!!? JH A H > =? F = A Figure 8: Internal cabling for 3-channel configuration - initial state 12 U41100-J-Z
19 PRIMERGY S40-DF capacity extension Converting the PRIMERGY S40-DF? = C A? = C A? = C A! Figure 9: Removing the STM-LVD modules Pull out the SCSI addressing cable (1) from the connection ports on the STM-LVD modules of the SCSI drive cages 2 and 3. I For cage 1, the STM-LVD module remains connected with the SCSI addressing cable on the backplane. Remove the STM-LVD modules (2) of the SCSI drive cages 2 and 3. Removing the STM-LVD module frees the SCSI connector X1 on the SCSI backplane (see also figure 12 on page 16). U41100-J-Z
20 Converting the PRIMERGY S40-DF PRIMERGY S40-DF capacity extension!!!! Figure 10: Controller backplane: SCSI ports - initial state Pull out the SCSI connection cable for cage 1 (3.1) from the controller backplane (see also figure 8 on page 12) and connect it to the freed SCSI connector X1 (see figure 12 on page 16) on the backplane of cage 2 (see figure 11 on page 15). Pull out the SCSI connection cable for cage 2 (3.2) from the controller backplane (see also figure 8 on page 12) and connect it to the freed SCSI connector X1 (see figure 12 on page 16) on the backplane of cage 3 (see figure 11 on page 15). Pull out the SCSI connection cable for cage 3 (3.3) from the controller backplane (see also figure 8 on page 12) and connect it to the first SCSI port on the backplane of the controller (see figure 11 on page 15 and figure 12 on page 16). 14 U41100-J-Z
21 PRIMERGY S40-DF capacity extension Converting the PRIMERGY S40-DF #! "? = C A!? = C A? = C A! $!! Figure 11: 1-Setting up the channel configuration Connect the supplied OLR/STM-LVD flat ribbon cable as follows: Connect the common end (4) of the two cable strands with the connector X5 on the STM-LVD module on the backplane of cage 1 (see also figure 12 on page 16). Connect the shorter strand (5) with the connector X4 on the backplane of cage 2 (see also figure 12 on page 16). Connect the longer strand (6) with the connector X4 on the backplane of cage 3 (see also figure 12 on page 16). This cable determines the SCSI addresses of the drives located in the SCSI cages 2 and 3 in the 1-channel configuration. U41100-J-Z
22 ! " Converting the PRIMERGY S40-DF PRIMERGY S40-DF capacity extension > =? F = A I? = C A!? = C A : " : "? = C A : : $ # 5 6 K A : #!! "? JH A H > =? F = A!! Figure 12: Internal cabling for 1-channel configuration - final state 16 U41100-J-Z
23 PRIMERGY S40-DF capacity extension Converting the PRIMERGY S40-DF Installing the LVD extender board The insertion slot for the LVD extender board is on the back of the storage subsystem and is covered by a plate. If you need further assistance, refer to the operating instructions for the PRIMERGY S40-DF Storage Subsystem. Figure 13: Removing the plate Loosen the two screws (1) and remove the plate covering the insertion slot (2). U41100-J-Z
24 Converting the PRIMERGY S40-DF PRIMERGY S40-DF capacity extension V CAUTION! Please observe the notes pertaining to the ESD label in the section Important notes on page 3. Figure 14: Installing the LVD extender board V CAUTION! Before installing the board, make sure that all DIP switches are set to ON. Insert the board into the free slot (1). Fasten the LVD extender board with the two knurled screws (2). 18 U41100-J-Z
25 PRIMERGY S40-DF capacity extension Converting the PRIMERGY S40-DF Connecting the capacity extension FCL-Adp. FCL-Adp. DAC 960 FL 0 PRIMERGY S40-DF 1 channel version LVD extender PRIMERGY S40-ES 1 channel version PRIMERGY S40-ES 1 channel version PRIMERGY S40-ES 1 channel version Figure 15: PRIMERGY S40-DF with capacity extension Connect each of the three PRIMERGY S40-ES subsystems (SCSI interface channel 0) using a SCSI cable to one of the three SCSI ports on the LVD extender of the PRIMERGY S40-DF. For further assistance in understanding these connections, see also the operating instructions for the PRIMERGY S40-BS/-ES Storage Subsystem and the PRIMERGY S40-DF Storage Subsystem, respectively. U41100-J-Z
26
27 Related publications Please apply to your local office for ordering the manuals. [1] Safety, Guarantee and Ergonomics [2] 19-Inch Rack for PRIMERGY and RM Systems Technical Manual [3] PRIMERGY S40-DF Storage Subsystem Operating Manual [4] PRIMERGY S40-BS/ES Storage Subsystem Operating Manual U41100-J-Z
28
29 Index C capacity expansion 1, 5, 11 configuration converting the internal configuration 11 conversion kit 5 E ESD label 3 L LVD extender board installing 17 M mounting/removing the protective shield 10 mounting/removing the side cover 9 N notational conventions 2 notes on safety 3 O OLR/STM-LVD flat ribbon cable 15 R removing/mounting the door 8 S SCSI addressing cable 13 SCSI ports final state 16 initial state 14 STM-LVD modules removing 13 T target group 2 transportation 4 U41100-J-Z
30
31 Fujitsu Siemens Computers GmbH User Documentation München Germany Fax: / Comments Suggestions Corrections manuals@fujitsu-siemens.com Submitted by Comments on PRIMERGY S40-DF Capacity Extension U41100-J-Z
32
33 Information on this document On April 1, 2009, Fujitsu became the sole owner of Fujitsu Siemens Computers. This new subsidiary of Fujitsu has been renamed Fujitsu Technology Solutions. This document from the document archive refers to a product version which was released a considerable time ago or which is no longer marketed. Please note that all company references and copyrights in this document have been legally transferred to Fujitsu Technology Solutions. Contact and support addresses will now be offered by Fujitsu Technology Solutions and have the The Internet pages of Fujitsu Technology Solutions are available at and the user documentation at Copyright Fujitsu Technology Solutions, 2009 Hinweise zum vorliegenden Dokument Zum 1. April 2009 ist Fujitsu Siemens Computers in den alleinigen Besitz von Fujitsu übergegangen. Diese neue Tochtergesellschaft von Fujitsu trägt seitdem den Namen Fujitsu Technology Solutions. Das vorliegende Dokument aus dem Dokumentenarchiv bezieht sich auf eine bereits vor längerer Zeit freigegebene oder nicht mehr im Vertrieb befindliche Produktversion. Bitte beachten Sie, dass alle Firmenbezüge und Copyrights im vorliegenden Dokument rechtlich auf Fujitsu Technology Solutions übergegangen sind. Kontakt- und Supportadressen werden nun von Fujitsu Technology Solutions angeboten und haben die Die Internetseiten von Fujitsu Technology Solutions finden Sie unter und unter finden Sie die Benutzerdokumentation. Copyright Fujitsu Technology Solutions, 2009
chipdisk for RemoteView
PRIMERGY chipdisk for RemoteView Xenia Fierley Siemens Nixdorf Informationssysteme AG Primergy 81730 Munich e-mail: Internet:DOCetc@mchp.siemens.de Tel.: (089) 636-47896 Fax: (++ 49) 89 6 36-4 87 17 U41102-J-Z156-1-74
More informationThe activities described in these upgrade instructions may only be performed by engineers or maintenance/technical staff.
Introduction The upgrade instructions show how to remove the standard power supply and replace it with a hotplug power supply. The following steps only apply to the PRIMERGY 400 and 00 tower servers.!
More informationFibreCAT TXF Backup Subsystem. Service Supplement
FibreCAT TXF Backup Subsystem Service Supplement Edition October 2008 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps
More informationR E L E A S E N O T I C E C O S M O S T O O L S V A. (c) Fujitsu Siemens Computers GmbH 2001
R E L E A S E N O T I C E C O S M O S T O O L S V 1 4. 0 A (c) Fujitsu Siemens Computers GmbH 2001 Word and Excel are registered trademarks of Microsoft Postscript is a registered trademark of Adobe Contents
More informationCopyright (C) Fujitsu Siemens Computers GmbH 2005 All rights reserved
Fujitsu Siemens Computers GmbH DRV (BS2000/OSD) Version 3.1A November 2005 Release Notice Copyright (C) Fujitsu Siemens Computers GmbH 2005 All rights reserved Release Notice DRV V3.1A 1 General 2 1.1
More informationCopyright (C) Fujitsu Siemens Computers GmbH 2005 All rights reserved
Fujitsu Siemens Computers GmbH SM2-TOOLS (BS2000/OSD) Version 7.5A Juli 2006 Release Notice Copyright (C) Fujitsu Siemens Computers GmbH 2005 All rights reserved Release Notice SM2-TOOLS V7.5A 1 General
More informationCopyright (C) Fujitsu Siemens Computers GmbH 2008 All rights reserved
Fujitsu Siemens Computers GmbH XHCS-SYS (BS2000/OSD) Version 2.0A June 2008 Release Notice Copyright (C) Fujitsu Siemens Computers GmbH 2008 All rights reserved Release Notice XHCS-SYS V2.0A 1 General
More informationFUJITSU SIEMENS COMPUTERS. Release Notice PCMX (LINUX-S390) V6.0A. Table of Contents
FUJITSU SIEMENS COMPUTERS Release Notice PCMX (LINUX-S390) V6.0A Table of Contents 1 General 1.1 Documentation 2 Notes on product use 2.1 Software/hardware configuration 2.1.1 Operating system 2.2 Resource
More informationWebTransactions V7.1. Supplement
WebTransactions V7.1 Supplement Edition: December 2006 This manual describes the new functions in WebTransactions V7.1. It is intended to supplement the WebTransactions V7.0 manuals. Comments Suggestions
More informationCopyright (C) Fujitsu Siemens Computers GmbH 2004 All rights reserved
Fujitsu Siemens Computers GmbH A I D Version 3.1 November 2004 Release Notice Copyright (C) Fujitsu Siemens Computers GmbH 2004 All rights reserved Release Notice AID V3.1 1 General....................
More informationPRIMERGY 670 Converting Guide
PRIMERGY 670 Converting Guide Server Systems A26361-K531-Z101-1-7419 Edition March 1999 Copyright and Trademarks Intel and Pentium are registered trademarks of Intel Corporation, USA. NetWare and Novell
More informationPRIMERGY TX200 S3 Server
PRIMERGY PRIMERGY TX200 S3 Server Service Supplement Susanne Däschlein Fujitsu Siemens Computers GmbH München 81730 München e-mail: email: manuals@fujitsu-siemens.com Tel.: (089) 61001155 Fax: (++49) 700
More informationFujitsu Siemens Computers. internet Value Edition. Version 1.0B. July Release Notice
Fujitsu Siemens Computers internet Value Edition Version 1.0B July 2002 Release Notice Copyright (C) Fujitsu Siemens Computers 2002 All rights reserved Release Notice internet Value Edition V1.0B 1 General.....................
More informationCopyright (C) Fujitsu Siemens Computers GmbH 2005 *3 All rights reserved *3
Fujitsu Siemens Computers GmbH CRTE (BS2000/OSD) Version 2.4C *4 October 2005 *4 Release Notice Copyright (C) Fujitsu Siemens Computers GmbH 2005 *3 All rights reserved *3 Release Notice CRTE V2.4C 1 General.....................
More informationPRIMERGY Econel 100 Server System
PRIMERGY PRIMERGY Econel 100 Server System Service Supplement Susanne Däschlein Fujitsu Siemens Computers GmbH München 81730 München e-mail: email: manuals@fujitsu-siemens.com Tel.: (0 89) 61 001-155 Fax:
More informationPRIMERGY TX150 S5 Server
PRIMERGY PRIMERGY TX150 S5 Server Service Supplement Susanne Däschlein Fujitsu Siemens Computers GmbH München 81730 München e-mail: email: manuals@fujitsu-siemens.com Tel.: (089) 61001155 Fax: (++49) 700
More informationEmanate Master 1.3. Readme. Edition June 2000
Solaris Emanate Master 1.3 Readme Redakteur Fujitsu Siemens Computers GmbH Paderborn 33094 Paderborn e-mail: email: manuals@fujitsu-siemens.com Tel.: (089) 636-00000 Fax: (++49) 700 / 372 00001 Bestellnummer
More informationThis symbol is followed by supplementary information, remarks and tips.
Introduction This Technical Manual describes the system boards of the PRIMERGY 870 server systems, which can be equipped with up to four Intel Xeon processors. You may find further information in the description
More informationPRIMERGY Econel 200 S2 Server
PRIMERGY PRIMERGY Econel 200 S2 Server Options Guide Susanne Däschlein Fujitsu Siemens Computers GmbH München 81730 Munich e-mail: email: manuals@fujitsu-siemens.com Tel.: (089) 61001-155 Fax: (++49) 700
More informationUsing Egenera Virtualized Boot Services
Using Egenera Virtualized Boot Services For BladeFrame BF400 S2 and BladeFrame BF200 Document Number 432-SB0045 September 2008 EVBS1.0_BF_1 Copyright Copyright 2008 Egenera, Inc. All rights reserved. This
More informationPRIMERGY BX630 S2 Scalable Server Blade. Options Guide
PRIMERGY BX630 S2 Scalable Server Blade Options Guide Edition October 2007 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback
More informationPRIMERGY RX100 S3 Server System
PRIMERGY PRIMERGY RX100 S3 Server System Options Guide Susanne Däschlein Fujitsu Siemens Computers GmbH München 81730 München e-mail: email: manuals@fujitsu-siemens.com Tel.: (089) 61001155 Fax: (++49)
More informationPRIMERGY Econel 100 Server System
PRIMERGY PRIMERGY Econel 100 Server System Options Guide Susanne Däschlein Fujitsu Siemens Computers GmbH München 81730 Munich e-mail: email: manuals@fujitsu-siemens.com Tel.: (0 89) 61 001-155 Fax: (++49)
More informationStreamer DAT160 Half-Height 80GB/160GB, USB 2.0
User Guide English Streamer DAT160 Half-Height 80GB/160GB, USB 2.0 Streamer DAT160 Half-Height 80GB/160GB, USB 2.0 User Guide Edition November 2008 Comments Suggestions Corrections The User Documentation
More informationPRIMERGY BX600 10GbE LAN I/O Module (PCIe)
Reference Guide PRIMERGY BX600 10GbE LAN I/O Module (PCIe) Microsoft Windows Server 2003 iscsiselect Reference Guide English PRIMERGY BX600 10GbE LAN I/O Module (PCIe) Microsoft Windows Server 2003 iscsiselect
More informationThe MTC Autoloader FibreCAT TX24 - Use with OSD/XC at SX Servers -
The MTC Autoloader FibreCAT TX24 - Use with OSD/XC at SX Servers - Readme File Contents 1 Introduction...2 2 Characteristics...4 2.1 General Characteristics...4 2.2 Release with OSD/XC...4 2.3 Hardware,
More informationLAN Manager/X V2.2. (SINIX) SNMP Service. System Administator's Guide
LAN Manager/X V2.2 (SINIX) SNMP Service System Administator's Guide Is there anything you want to tell us about this manual? Please send us your comments, quoting the order number of the manual. Siemens
More informationPRIMERGY RX200 S3 Server. Options Guide
PRIMERGY RX200 S3 Server Options Guide Edition August 2006 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps us optimize
More informationSLR 50/100 GBYTE BETRIEBSANLEITUNG OPERATING MANUAL
SLR 50/100 GBYTE BETRIEBSANLEITUNG OPERATING MANUAL Dieses Handbuch wurde auf Recycling-Papier gedruckt. This manual has been printed on recycled paper. Ce manuel est imprimé sur du papier recyclé. Este
More informationSTREAMER 30/60 GBYTE BETRIEBSANLEITUNG OPERATING MANUAL
STREAMER 30/60 GBYTE BETRIEBSANLEITUNG OPERATING MANUAL Dieses Handbuch wurde auf Recycling-Papier gedruckt. This manual has been printed on recycled paper. Ce manuel est imprimé sur du papier recyclé.
More information8 Mailsender. internet Services V3.1A 1
8 Mailsender Files can be sent and processed as e-mail in BS2000/OSD using a local user agent, the BS2000/OSD Mailsender. The BS2000/OSD Mailsender allows you to send automated lists as e-mail from BS2000/OSD
More informationPRIMERGY BX630 Scalable Server Blade
PRIMERGY PRIMERGY BX630 Scalable Server Blade Service Supplement Redakteur Fujitsu Siemens Computers GmbH Paderborn 33094 Paderborn e-mail: email: manuals@fujitsu-siemens.com Tel.: (089) 61001-??? Fax:
More informationProduktfamilie PRIMERGY RX200 S2
Produktfamilie PRIMERGY RX200 S2 D1790 Setup Utility Hans-Joachim Kneba Fujitsu Siemens Computers GmbH Paderborn 33094 Paderborn e-mail: email: manuals@fujitsu-siemens.com Tel.: 05251/8-14865 Fax: (++49)
More informationRelease Information for FlexFrame V4.0A10 for SAP
Release Information for FlexFrame V4.0A10 for SAP Copyright 2008 Fujitsu Siemens Computers Table of Contents General... 1 Ordering... 1 Delivery... 1 Documentation... 2 Software Extensions / New Functionality...
More informationPRIMERGY BX630 S2 Scalable Server-Blade. Service Supplement
PRIMERGY BX630 S2 Scalable Server-Blade Service Supplement Edition December 2007 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your
More informationPAN Manager Feature Summary
PAN Manager Feature Summary For BladeFrame BF400 S2 and BladeFrame BF200 Document Number 430-SB0073 August 2008 PM5.2_BF Copyright Copyright 2008 Egenera, Inc. All rights reserved. This document, and the
More informationSTREAMER VXA /320 GB
Operating Manual English STREAMER VXA-320 160/320 GB Are there...... any technical problems or other questions you need clarified? Please contact our Help Desk (see warranty card). The latest information
More informationSystem board D2004 for RX100 S3
PRIMERGY System board D2004 for RX100 S3 Technical manual Däschlein Fujitsu Siemens Computers GmbH München 81730 Munich e-mail: email: manuals@fujitsu-siemens.com Tel.: (089) 61001-155 Fax: (++49) 700
More informationSESAM-DBAccess (JDBC) V4.0A. Server Installation, Administration
SESAM-DBAccess (JDBC) V4.0A Server Installation, Administration Edition December 2005 Comments Suggestions Corrections The User Documentation Department would like to know your opinion on this manual.
More informationPRIMERGY S40-BS/-ES Storage Subsystem
Primergy PRIMERGY S40-BS/-ES Storage Subsystem Xenia Fierley Fujitsu Siemens Computers GmbH cognitas PS 81730 München e-mail: email: manuals@fujitsu-siemens.com Tel.: (089) 61001-157 Fax: 0 700 / 372 00000
More informationSESAM-DBAccess (JDBC) V5.0A. Server Installation, Administration
SESAM-DBAccess (JDBC) V5.0A Server Installation, Administration Edition December 2006 Comments Suggestions Corrections The User Documentation Department would like to know your opinion on this manual.
More informationSystem board D2020 for Econel 200
Produktfamilie System board D2020 for Econel 200 Technical manual Redakteur Fujitsu Siemens Computers GmbH München 81730 Munich e-mail: email: manuals@fujitsu-siemens.com Tel.: (089) 61001-??? Fax: (++49)
More informationINSTALLATION GUIDE System Console Software 2.0 for Solaris Environment
INSTALLATION GUIDE System Console Software 2.0 for Solaris Environment High Risk Activity The Customer acknowledges and agrees that the Product is designed, developed and manufactured as contemplated for
More informationSystem Board D2619 for RX/TX300 S5. Technical Manual
System Board D2619 for RX/TX300 S5 Technical Manual Edition April 2009 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps
More informationStreamer LTO-3 half height 400GB/800GB SCSI Ultra320
Operating Manual English Streamer LTO-3 half height 400GB/800GB SCSI Ultra320 Are there...... any technical problems or other questions you need clarified? Please contact our Help Desk (see warranty card
More informationSystem Board D2559 for TX150 S6. Technical Manual
System Board D2559 for TX150 S6 Technical Manual Edition November 2007 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps
More informationSystem Board D2785 for TX120 S2. Technical Manual
System Board D2785 for TX120 S2 Technical Manual Edition April 2009 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps
More informationSystem Management Console Security Development Guide C120-E142-01EN
System Management Console Security Development Guide C120-E142-01EN Trademarks and Acknowledgement UNIX is a registered trademark in the United States and other countries, licensed exclusively through
More information*5 Fujitsu Siemens Computers GmbH DRIVE/WINDOWS (BS2000) *5 Version 2.1B40
*5 Fujitsu Siemens Computers GmbH DRIVE/WINDOWS (BS2000) *5 Version 2.1B40 Release Notice DRIVE/WINDOWS V 2.1B C o n t e n t s 1 General................ 1 1.1 Ordering............... 2 1.2 Delivery...............
More informationPRIMERGY RX300 S2 Server System
PRIMERGY PRIMERGY RX300 S2 Server System Monika Spanjaart Fujitsu Siemens Computers GmbH München 81730 Munich e-mail: email: manuals@fujitsu-siemens.com Tel.: (089) 61001160 Fax: (++49) 700 / 372 00000
More informationopenft_ux-readme.txt Fujitsu Siemens Computers openft V8.1A20 for Unix systems openft-ftam V8.0B for Unix systems March 2006 Release notice
Fujitsu Siemens Computers openft V8.1A20 for Unix systems openft-ftam V8.0B for Unix systems March 2006 Release notice RELEASE NOTICE openft V8.1A20 for Unix systems openft-ftam V8.0B for Unix systems
More informationFujitsu Siemens Computers. internet Services (BS2000/OSD) Version 3.1A May Release Notice
Fujitsu Siemens Computers internet Services (BS2000/OSD) Version 3.1A May 2005 Release Notice Copyright (C) Fujitsu Siemens Computers 2005 All rights reserved Release Notice internet Services V3.1A 1 General
More informationTechnical Manual. Mainboard D1483. English
answers 2 Technical Manual Mainboard D1483 English Are there...... any technical problems or other questions you need clarified? Please contact: your sales partner your sales outlet You will find further
More information1.1 Summary of contents and target group
1 Preface The openutm Universal Transaction Monitor is a comprehensive middleware platform, offering a wealth of options for designing and implementing transaction-oriented OLTP applications, as well as
More informationSystem Board D2671 for RX200 S4. Technical Manual
System Board D2671 for RX200 S4 Technical Manual Edition December 2007 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps
More informationPRIMERGY RX300 S4. Options Guide
PRIMERGY RX300 S4 Options Guide Edition June 2008 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps us optimize our
More informationPRIMERGY TX150 S5 Server
PRIMERGY PRIMERGY TX150 S5 Server Options Guide Däschlein Fujitsu Siemens Computers GmbH München 81730 München e-mail: email: manuals@fujitsu-siemens.com Tel.: (089) 61001155 Fax: 0 700 / 372 00000 TX150
More informationSystembaugruppe / System Board D1570-A11
Technisches Handbuch / Technical Manual Systembaugruppe / System Board D1570-A11 Deutsch / English Sie haben...... technische Fragen oder Probleme? Wenden Sie sich bitte an: Ihren zuständigen Vertriebspartner
More informationPRIMERGY SX30 Storage Subsystem
Primergy PRIMERGY SX30 Storage Subsystem Operating Manual Günter Benkelberg Fujitsu Siemens Computers GmbH Paderborn 81730 München e-mail: Internet:manuals@fujitsu-siemens.com Tel.: 0 52 51 / 81 48 91
More informationSerial ATA Hot Swap Drive Cage Upgrade Kit for: Intel Server Chassis SC5200 Intel Server Chassis SC5250-E
Serial ATA Hot Swap Drive Cage Upgrade Kit for: Intel Server Chassis SC5200 Intel Server Chassis SC5250-E A Guide for Technically Qualified Assemblers of Intel Identified Subassemblies/Products Order Number:
More informationPRIMERGY TX150 S6 Server. Options Guide
PRIMERGY TX150 S6 Server Options Guide Edition June 2009 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps us optimize
More informationPRIMERGY TX300 S4. Options Guide
PRIMERGY TX300 S4 Options Guide Edition April 2008 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps us optimize our
More informationPRIMERGY TX300 S3 Server
PRIMERGY PRIMERGY TX300 S3 Server Options Guide Susanne Däschlein Fujitsu Siemens Computers GmbH München 81730 München e-mail: email: manuals@fujitsu-siemens.com Tel.: (089) 61001155 Fax: (++49) 700 /
More informationDell OptiPlex All-in-One. Stand Installation Guide
Dell OptiPlex All-in-One Stand Installation Guide Notes, cautions, and warnings NOTE: A NOTE indicates important information that helps you make better use of your product. CAUTION: A CAUTION indicates
More informationPRIMERGY SX650 Storage Blade. Operating Manual
PRIMERGY SX650 Storage Blade Operating Manual Edition April 2009 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps us
More informationUser Guide - English. FUJITSU Software ServerView Suite. Local Service Panels. Local Service Concept (LSC)
User Guide - English FUJITSU Software ServerView Suite Local Service Panels Local Service Concept (LSC) Last Edition August 2017 Comments Suggestions Corrections The User Documentation Department would
More informationPRIMERGY TX120 S2 Server. Service Supplement
PRIMERGY TX120 S2 Server Service Supplement Edition July 2009 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps us optimize
More informationPRIMERGY BX920 S1 Server-Blade. Service Supplement
PRIMERGY BX920 S1 Server-Blade Service Supplement Edition April 2010 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps
More informationCPCI-PS24 24V-Power Supply
24V-Power Supply Hardware Manual to Product I.2301.21 esd electronic system design gmbh Vahrenwalder Str. 207 30165 Hannover Germany http://www.esd.eu Phone: +49 (0) 511 3 72 98-0 Fax: +49 (0) 511 3 72
More informationB63/ NS MS. EtherNet/IP LINK
3 609 929 B63/ IMenip 2008-09 NS MS EtherNet/IP LINK 3 609 929 B63/2008-09 IMenip Bosch Rexroth AG 15/76 Table of Contents About this document................. 16 General safety instructions............
More informationPRIMERGY BX620 S3 2-way Server Blade
PRIMERGY PRIMERGY BX620 S3 2-way Server Blade Options Guide Walter Dick Fujitsu Siemens Computers GmbH Paderborn 33094 Paderborn e-mail: email: manuals@fujitsu-siemens.com Tel.: (0 52 51)14888-12 Fax:
More informationSystem Board D2129 for TX300 S3
PRIMERGY System Board D2129 for TX300 S3 Technical Manual Susanne Däschlein Fujitsu Siemens Computers GmbH München 81730 München e-mail: email: manuals@fujitsu-siemens.com Tel.: (089) 61001-155 Fax: (++49)
More informationPS/IO Circuit Board Retrofit
S&C 6800 Series Automatic Switch Controls PS/IO Circuit Board Retrofit Table of Contents Section Page Introduction Qualified Persons.... 2 Read this Instruction Sheet.... 2 Retain this Instruction Sheet....
More informationPRIMERGY RX300 S5. Service Supplement
PRIMERGY RX300 S5 Service Supplement Edition June 2009 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps us optimize
More informationSystem Board D2119 for RX300 S3
PRIMERGY System Board D2119 for RX300 S3 Technical Manual Martin Jung Fujitsu Siemens Computers GmbH München 81730 München e-mail: email: manuals@fujitsu-siemens.com Tel.: (089) 61001-154 Fax: (++49) 700
More informationTRC-190 User s Manual
User s Manual Edition 3.2, May 2017 www.moxa.com/product 2017 Moxa Inc. All rights reserved. User s Manual The software described in this manual is furnished under a license agreement and may be used only
More informationPRIMERGY BX400 S1 System Unit
Options Guide - English PRIMERGY BX400 S1 System Unit Options Guide December 2010 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your
More informationPRIMERGY RX200 Server System
PRIMERGY PRIMERGY RX200 Server System Operating Manual Xenia Fierley Fujitsu Siemens Computers GmbH München 81730 München e-mail: email: manuals@fujitsu-siemens.com Tel.: (089) 61001--157 Fax: (++49) 700
More informationPRIMERGY TX200 S2 Server System
PRIMERGY PRIMERGY TX200 S2 Server System Operating Manual Xenia Fierley Fujitsu Siemens Computers GmbH München 81730 München e-mail: email: manuals@fujitsu-siemens.com Tel.: (089) 61001157 Fax: (++49)
More informationPRIMERGY Econel 200 Server System
PRIMERGY PRIMERGY Econel 200 Server System Operating Manual Gottfried Staubach/Xenia Fierley Fujitsu Siemens Computers GmbH München 81730 München e-mail: email: manuals@fujitsu-siemens.com Tel.: (05251)
More informationBasisinformationen Mainboard Basic information on mainboard
Mainboard Deutsch - English Technisches Handbuch / Technical Manual Basisinformationen Mainboard Basic information on mainboard Sie haben...... technische Fragen oder Probleme? Wenden Sie sich bitte an:
More informationPRIMERGY L200 Server System
PRIMERGY PRIMERGY L200 Server System Jacob Fujitsu Siemens Computers GmbH München 81730 Munich e-mail: Internet:manuals@fujitsu-siemens.com Tel.: (089) 61001-161 Fax: (++49) 700 / 372 00000 A26361-K647-Z102-3-7619
More informationanswers SCENIC P / SCENICO P / SCENIC Edition X100 Getting Started English
answers 2 Getting Started SCENIC P / SCENICO P / SCENIC Edition X100 English Are there...... any technical problems or other questions which you would like to be clarified? Please contact: your sales partner
More informationCommunication Interface for SMA Inverters SMA BLUETOOTH PIGGY-BACK
Communication Interface for SMA Inverters SMA BLUETOOTH PIGGY-BACK Installation Guide BTPB-IEN112112 98-0014212 Version 1.2 EN SMA Solar Technology AG Table of Contents Table of Contents 1 Notes on this
More informationPRIMERGY RX300 S3 Server. Options Guide
PRIMERGY RX300 S3 Server Options Guide Edition June 2007 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps us optimize
More informationETERNUS JX60. Technical Product Introduction. 0 Copyright Fujitsu, Release June 2014
0 Copyright Fujitsu, Release June 2014 Highlights The passive storage subsystem accommodates up to 240 HDDs 3.5" SAS 2.0 Nearline SAS 7200 rpm, max. storage capacity 960 TB 1) One or two 6 Gbit/s SAS interfaces
More informationTRC-190 User s Manual
First Edition, November 2008 www.moxa.com/product 2008 Moxa Inc. All rights reserved. Reproduction without permission is prohibited. The software described in this manual is furnished under a license agreement
More information120Ra-1 Pentium III Processor Installation Insert
120Ra-1 Pentium III Processor Installation Insert PN: 455-01614-000 Proprietary Notice and Liability Disclaimer The information disclosed in this document, including all designs and related materials,
More informationSerial Module RS232C Standard. Technical Description
Computertechnik GmbH Serial Module RS232C Standard Technical Description Order number: 404.249010.000 6 ISA96 Serial Module RS323C standard Your contact: 2001 by Janich & Klass Computertechnik GmbH, Wuppertal
More informationAllen-Bradley Drives. Instructions. (For 6180 Industrial Computers)
Instructions (For 6180 Industrial Computers) This document describes how to remove or install a Pentium processor in the 6180 Industrial Computer. Processor specifications are also provided. The processor
More informationHP ProLiant DL165 G7 Server
HP ProLiant DL165 G7 Server Installation Instructions Part Number 601464-003 Identifying server components Front panel components Figure 1 Front Panel Components / 4 3.5 LFF HDD Item Description 1 Thumbscrews
More informationRADEON /RADEON VE Getting Started...
RADEON /RADEON VE Getting Started... Safety Instructions for TV Tuner Products Installing Your RADEON /RADEON VE Installing the ATI Driver for Windows 98, Windows Me Installing the ATI Driver for Windows
More informationPRIMERGY RX600 S4 Server. Service Supplement
PRIMERGY RX600 S4 Server Service Supplement Edition December 2007 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps
More information3 Here is a short overview of the specifications. A link to a data sheet with full specification details is given later in this web based training
1 Welcome to this web based training session. This presentation provides you an introduction to the Fujitsu ETERNUS JX40. The JX40 is a passive direct server attached drive extension offering extension
More informationOptiPlex XE3 Tower. Remote Power Switch Installation Guide. Regulatory Model: D18M Regulatory Type: D18M005
OptiPlex XE3 Tower Remote Power Switch Installation Guide Regulatory Model: D18M Regulatory Type: D18M005 Notes, cautions, and warnings NOTE: A NOTE indicates important information that helps you make
More informationDell Precision 3430 Small Form Factor
Dell Precision 3430 Small Form Factor USB Type-C card Installation Guide Regulatory Model: D11S Regulatory Type: D11S004 Notes, cautions, and warnings NOTE: A NOTE indicates important information that
More informationInstalling the EN-4000
EN-4000 Reference Manual Document 2 Installing the EN-4000 T his document discusses installation of the EN-4000 hardware. Note: The EN-4000 Quick Installation Guide is also available. 2.1 Collecting the
More informationPRIMERGY TX300 Server System
PRIMERGY PRIMERGY TX300 Server System Operating Manual Xenia Fierley Fujitsu Siemens Computers GmbH München 81730 München e-mail: email: manuals@fujitsu-siemens.com Tel.: (089) 61001157 Fax: 0 700 / 372
More informationRelease Notes for the Cisco Catalyst Blade Switch 3040 for FSC, Cisco IOS Release 12.2(37)SE
Release Notes for the Cisco Catalyst Blade Switch 3040 for FSC, Cisco IOS Release 12.2(37)SE May 11, 2007 Cisco IOS Release 12.2(37)SE runs on the Cisco Catalyst Blade Switch 3040 for FSC, referred to
More informationInstallation Job Aid for Ethernet Routing Switch 5900 Series
Installation Job Aid for Ethernet Routing Switch 5900 Series Notices NN47211-301 Issue 05.01 November 2017 Notice paragraphs alert you about issues that require your attention. The following paragraphs
More information