Hoods, grilles and transitions

Size: px
Start display at page:

Download "Hoods, grilles and transitions"

Transcription

1 Hoods, grilles and s lindab residential ventilation Residential ventilation Circular duct systems Hoods, grilles and s Dampers Silencers Valves and Grilles InCapsa InDomo Access doors Accessories Air handling units Index

2 Content hoods weather protections VH... 0 HN... H... HV... HU... VHA... VHP... VHL... LHR... 0 HVR... HRR... HKOMR... VHING/VHINP... 0 UG... Vapour membranes MG... MGL... s fasteners SR... SRI... SRIP... GISOL... GISOLP... TGR... TGFR... TGKOMR... SBG... SBGR... SBG... pieces AGIS... Wall grilles YGC... H... VR... AVU... EPNF... ESNU... ILRNU... We reserve the right to make changes without prior notice

3 Hoods, grilles and s lindab residential ventilation General Extract air All Lindab s roof hoods are suitable for use as extract air hoods. When choosing extract air hood, the architectural design is important to ensure that the hood is in harmony with the rest of the building. Our range includes ribbed hoods, rectangular and circular roof hoods, models that are available with inclines adapted to the angle of the roof, as well as products with a horizontal profile, of course. If a high extract velocity and long ejection distance are required, choose our HN and HF roof hoods. NOTE! When fans are not running there is always a risk for drifting snow and damp to penetrate into ducts. At some occasions also condensation can cause trouble. Outdoor air Out of Lindab s range of roof hoods, HN and HF are not suitable as outdoor air hoods. When choosing outdoor air hoods, too, the architectural design is important to ensure that it is in harmony with the rest of the building. Lindab s range of outdoor air hoods includes the same design as for extract air hoods (see above). Connection options Connection to a sleeve, flange or directly to the roof through must always be specified where these alternatives are possible. The recoended roof through is specified for each hood. Version Material Lindab s roof hoods are manufactured as follows. Galvanised sheet metal, aluzink sheet AZ, stainless steel sheet.0, stainless acid-resistant steel sheet.0 and painted as detailed below. With these alternatives we cover up to and including corrosion class C. Painting We have standard colours (see below) but can also supply other colours to specification. Standard colours Black 0 RAL 00, brick red RAL 00, zinc grey RAL 00. However, this does not apply to VHL and LHR, where black RAL 00 and grey RAL 0 are the standard colours. Noise dispersion outdoors without obstacle Dimensioning Extract air If high extract velocities are not required, as low a pressure drop as possible is desirable. The pressure drop should not exceed 0 Pa in order to minimise self-generated noise emissions and energy consumption. L w = 0 db 0 m 0 m Outdoor air When outdoor air hoods are used, there is always a risk of water and snow entering the duct. In order to minimise this risk, the velocity over the free area must not exceed m/s. Location When locating roof hoods, the design of the roof should be taken into consideration to ensure that there are no snow pockets. The hoods must also be positioned so that extract fumes from vehicles etc. cannot be drawn into the outdoor air hood. In the same way, it is necessary to avoid short-circuits arising between outdoor air and extract air. If there is a risk of short-circuits, our combination hood HKOMR should be chosen in the first instance. Noise To avoid self-generated noise emissions, the pressure drop must not exceed 0 Pa. At this pressure drop, self-generated noise emissions are so low that they do not need to be added to the fan noise. To calculate noise to the surrounding environment, the calculation example shown to the right can be used. L W = Sound power level radiated from sound source [db] r = Distance from sound source to point of listening [m] L p = Sound pressure level at point of listening [db] Q = Direction factor [ ] = in free field, far from all surfaces = on one surface = in the corner between two surfaces = in the corner between three surfaces π r L = L log p w Q π 0 L = 0 log p = db π 0 L = 0 log p = db We reserve the right to make changes without prior notice

4 Hoods, grilles and s Example Noise from roof hood Conditions A level of 0 db(a) has been measured metres from an existing roof hood, the noise output level of which we do not know. This is now to be moved, and we want to know the sound pressure level 0 metres from its new location closer to a vertical wall surface. We assume that the noise from the fan is unchanged in the two cases. Lp = 0 db m 0 m First you extract the sound power level L W from the equation above. π r L = L + log W p Q π L = 0 + log W = db I.e. the radiated sound power level L W from the hood = db. π r L = L log p w Q π 0 L = log p = db I.e. the sound pressure level at 0 m distance from the new location is db. We reserve the right to make changes without prior notice

5 Hoods, grilles and s lindab residential ventilation Products used for penetration of roof Prinipal sketch hood piece, upper weather protection, outer weather protecation, inner Vapour membrane fastener piece, lower Duct We reserve the right to make changes without prior notice

6 hood VH h H Description hood VH is constructed as outdoor air inlet for both industrial and comfort ventilation, but can also be used as exhaust air hood. The hood is made of galvanized steel sheet, but can on order also be delivered in other materials like stainless steel, aluminium and powder painted sheet metal in different colours. It is provided with net and sleeve, which secures an effective protection against rain, falling leaves etc. The standard design is with a coupling, but the hood can on order be delivered with flange or as desired. VH can also be delivered in intermediate dimensions. Note: When used as an air inlet hood it is recoended that the velocity in the duct is kept below m/s in order to aviod water to be dragged in. Ød ØD Ød nom ØD h H Free area m m kg ,0 0, ,0 0,0 0 0,0 0, ,0, ,0, ,0, ,0, Ordering example Product Dimension Ød VH 0 0 We reserve the right to make changes without prior notice

7 hood VH Technical data (Pa) Δpt [Pa] q 0000 [m /h] (Pa) Δpt [Pa] [m/h] q We reserve the right to make changes without prior notice

8 hood VH piece, upper AGIS TGR-OA SR SRI SRIP VHING / VHINP Sits around the roof weather protection, outer GISOL / GISOLP TGR UG weather protection, inner MG / MGL Vapour membrane piece, lower SR TGR-NA LKR SBG fastener Ducting This diagram shows pricipally all possible combinations of how the products can be joined together. Normally only one alternative is chosen and sometimes some options are omitted. For some combinations the needed size of a product isn't presented in the catalogue. In these cases the size needed most often can be produced and delivered to order. We reserve the right to make changes without prior notice

9 hood HN H h Description Ventilation hood for air exit above roof, suitable for both industrial and comfort ventilation. The air is ejected in an upwards-directed jet. This avoids contaminating the air in the vicinity of the hood, and soiling of the area around the hood. The ejection is so effective that you can install a fresh air inlet in the iediate vicinity of the hood, without any special precautions. The hood is made of galvanised sheet steel, and can also be supplied in other materials such as stainless steel sheet.0, stainless acid-resistant steel sheet.0, aluzinc AZ and painted in various colours, to special order. It has a net over the opening and an internal rain funnel to collect rainwater and snow, which is drained out of the hood through a hose. The hose can withstand temperatures of between - and + C. The hood has a female, which fits outside a ventilation duct. The hood can be ordered with other s, however. As special delivery the hood can be supplied with three anchoring wire-loops. Ød nom ØD Technical data H Ød ØD h m kg through TGR 0 0 Size , , 0 0, 0 0 0, 00 0, , 0 0, L WA [db] Ød [] Δ pt [Pa] Ordering example Product Dimension Ød HN [l/s] [m/h] q We reserve the right to make changes without prior notice

10 HN hood piece, upper AGIS TGR-OA SR SRI SRIP VHING / VHINP Sits around the roof weather protection, outer GISOL / GISOLP TGR UG weather protection, inner MG / MGL Vapour membrane piece, lower TGR-NA SBG fastener SR LKR Ducting This diagram shows pricipally all possible combinations of how the products can be joined together. Normally only one alternative is chosen and sometimes some options are omitted. For some combinations the needed size of a product isn't presented in the catalogue. In these cases the size needed most often can be produced and delivered to order. We reserve the right to make changes without prior notice

11 hood H ØD H Description Circular roof hood intended for outdoor air and extract air. The hood is designed for location above the roof with or without a roof through. The air runs both on the top- and downside of the hood. This is valid both for outdoor and extract air. The hood is free-draining downwards. Can also be supplied with a pest-proof mesh. NOTE! When fans are not running there is always a risk for drifting snow and damp to penetrate into ducts. At some occasions also condensation can cause trouble. H is manufactured as standard from galvanised steel sheet Z, but is also available in aluminium zinc AZ, stainless steel sheet.0, stainless acid-resistant steel sheet.0 or painted. H in dimensions 0 has a sleeve as standard and fits on the outside of ventilation ducts are supplied with flange (including counter-flange) as standard. They are also supplied with twistable lifting and anchoring eyelets. An individual anchoring eyelet must not be subjected to forces in excess of 00 N. All dimensions can also be obtained with s that fit directly to the roof through TGR. Ordering example H Product Dimension Ød Connection options Sleeve (standard 0 ) Flange (standard 00 0) Transition piece to roof through Specify size of roof through according to the measurement table to the right. Specify separately if the hood is to be supplied with a pestproof mesh from the factory. Standard colours, see page. Ød nom ØD Technical data Δpt [Pa] H Ød Free area m m kg through TGR 0 0 Size 0 0 0,00 0, ,0,0 0 0,00, ,0, 0 0 0,0, 0 0,0, Ø D [l/s] q [m³/h] We reserve the right to make changes without prior notice

12 H hood piece, upper AGIS TGR-OA SR SRI SRIP VHING / VHINP Sits around the roof weather protection, outer GISOL / GISOLP TGR UG weather protection, inner MG / MGL Vapour membrane piece, lower TGR-NA SBG fastener SR LKR Ducting This diagram shows pricipally all possible combinations of how the products can be joined together. Normally only one alternative is chosen and sometimes some options are omitted. For some combinations the needed size of a product isn't presented in the catalogue. In these cases the size needed most often can be produced and delivered to order. We reserve the right to make changes without prior notice

13 hood HV ØD H h Description Circular roof hood with angled upper side intended for outdoor air and extract air. The hood is designed for location above the roof with or without a roof through. The air runs both on the top- and downside of the hood. This is valid both for outdoor and extract air. The hood is free-draining downwards. Can also be supplied with a pestproof mesh. NOTE! When fans are not running there is always a risk for drifting snow and damp to penetrate into ducts. At some occasions also condensation can cause trouble. HV is manufactured as standard from galvanised steel plate Z, but is also available in aluminium zinc AZ, stainless steel sheet.0, stainless acid-resistant steel sheet.0 or painted. HV is available with different angles in order to be in harmony with the architectural design of the building. HV in dimensions 0 has a sleeve as standard and fits on the outside of ventilation ducts are supplied with flange (including counter-flange) as standard. They are also supplied with twistable lifting and anchoring eyelets. An individual anchoring eyelet must not be subjected to forces in excess of 00 N. All dimensions can also be obtained with s that fit directly to the roof through TGR. Ordering example HV Product Dimension Ød Connection options Sleeve (standard 0 ) Flange (standard 00 0) Transition piece to roof through Specify size of roof through according to the measurement table to the right. Specify separately if the hood is to be supplied with a pestproof mesh from the factory and if a special angle is required. Standard colours, see page. Ød nom ØD h Technical data Δpt [Pa] H α Ød Free area m² m kg through TGR 0 0 Size 0 0 0,00 0, ,0, 0 0,00, ,0, 0 0 0,0,0 0 0,0, Ø D [l/s] [m³/h] q We reserve the right to make changes without prior notice

14 HV hood piece, upper AGIS TGR-OA SR SRI SRIP VHING / VHINP Sits around the roof weather protection, outer GISOL / GISOLP TGR UG weather protection, inner MG / MGL Vapour membrane SBG fastener piece, lower TGR-NA SR LKR Ducting This diagram shows pricipally all possible combinations of how the products can be joined together. Normally only one alternative is chosen and sometimes some options are omitted. For some combinations the needed size of a product isn't presented in the catalogue. In these cases the size needed most often can be produced and delivered to order. We reserve the right to make changes without prior notice

15 hood HU Ø0 00 Ø0 00 ØD ØD H h H h Ød Ød Description For air exit above roof. Provided with a female which fits outside a ventilation duct. Ød nom ØD H h m kg through TGR 0 0 Size , 0, , 00,0 0 00, 00 0, Technical data [Pa] Ød [] Ordering example Product Dimension Ød HU 0 Δp t q v [m/s] [l/s] [m²/h] We reserve the right to make changes without prior notice

16 HU hood piece, upper AGIS TGR-OA SR SRI SRIP VHING / VHINP Sits around the roof weather protection, outer GISOL / GISOLP TGR UG weather protection, inner MG / MGL Vapour membrane SBG fastener piece, lower TGR-NA SR LKR Ducting This diagram shows pricipally all possible combinations of how the products can be joined together. Normally only one alternative is chosen and sometimes some options are omitted. For some combinations the needed size of a product isn't presented in the catalogue. In these cases the size needed most often can be produced and delivered to order. 0 We reserve the right to make changes without prior notice

17 hood VHA H Description The VHA exhaust hood gives the possibility for an architectally correct ending of air outlet on the roof. The exhaust hood is as standard delivered in galvanised design, but can also be delivered in black powder coating. The hood is equipped with an internal cone, which leads the rain water out over the duct sides. The air is thrown away with an upward jet. Hence pollution of the air around the hood and dirt on the roof surface around the hood. The exhaust is so effective that quite easily an air intake can be mounted close up, e.g. lamella hood VHL, which designwise suits VHA. Exhaust hood: VHA = galvanized VHA-S = black powder coated Ød nom ØD nom Ød ØD H Free area m² m kg 0 0,0 0, ,0, ,0, ,0, ,0, ,0,0 Alternative Alternative ØD Ød Ordering example Product Dimension Ød Dimension ØD Colour, if desired VHA 00 We reserve the right to make changes without prior notice

18 hood VHA Technical data Pressure drop Δpt [Pa] [m /h] q Sound data L WA [db] ,0 0,0 0, 0, 0, 0, 0,,0,0,0,0,0,0 m /s m /h q We reserve the right to make changes without prior notice

19 VHA hood piece, upper TGR-OA SR SRI SRIP VHING / VHINP Sits around the roof weather protection, outer GISOL / GISOLP TGR UG weather protection, inner MG / MGL Vapour membrane piece, lower SR TGR-NA LKR SBG fastener Ducting This diagram shows pricipally all possible combinations of how the products can be joined together. Normally only one alternative is chosen and sometimes some options are omitted. For some combinations the needed size of a product isn't presented in the catalogue. In these cases the size needed most often can be produced and delivered to order. We reserve the right to make changes without prior notice

20 hood VHP H Description The VHP hood is developed specially to achieve an architectally correct ending of air intake and outlet on the roof. The hood is as standard delivered in galvanised design, can also be delivered in grey VHPG, or other colours. Ød nom ØD H Ød ØD Free area m² m kg *m³/h Flow inlet 0 0 0,0, ,0, ,0, ,0, ,, ,,00 00 * Recoended maximum air flow when use of VHP as intake hood. H = building in measure. Alternative Alternative ØD Ød Ordering example Product Dimension Ød Dimension ØD Colour, if desired VHP S We reserve the right to make changes without prior notice

21 hood VHP Technical data Δpt [Pa] L w [db(a)] [l/s] [m/h] q Δpt [Pa] q 0 L w [db(a)] [l/s] [m/h] We reserve the right to make changes without prior notice

22 VHP hood piece, upper TGR-OA SR SRI SRIP VHING / VHINP Sits around the roof weather protection, outer GISOL / GISOLP TGR UG weather protection, inner MG / MGL Vapour membrane piece, lower SR TGR-NA LKR SBG fastener Ducting This diagram shows pricipally all possible combinations of how the products can be joined together. Normally only one alternative is chosen and sometimes some options are omitted. For some combinations the needed size of a product isn't presented in the catalogue. In these cases the size needed most often can be produced and delivered to order. We reserve the right to make changes without prior notice

23 hood VHL H 0 Description The VHL lamella hood is developed specially to achieve an architectally correct ending of air intake and outlet on the roof. The lamella hood is as standard delivered in galvanised design, can also be delivered in black powder coating. In order to achieve a harmonic from duct to hood, the to the hood can be choosen either as a duct or as a roof (e.g. GISOL or GISOLP) with its dimensions corresponding to ØD, below the roof the duct may be reduced to Ød (see mounting proposal ). The lamella hood can well also be mounted directly on a duct with the diameter Ød (see mounting proposal ). When connecting to the roof through TGR, the special piece TGR-VHL must be used (see page ). Ød nom ØD H Ød ØD Free area m m kg Outdoor air max. rec. * *m³/h through TGR 0 0 Size 0 0,0,0 0 0,0, ,0, ,0, ,, ,,0 00 * Recoended maximum air flow when use of VHL as intake hood. H = building in measure. Alternative Alternative ØD Ød Ordering example Product Dimension Ød Dimension ØD Colour, if desired VHL 0 S We reserve the right to make changes without prior notice

24 hood VHL Technical data Outdoor air Δ p t [Pa] LW [db (A)] l/s q m ³ /h Extract air Δ p t [Pa] LW [db (A)] l/s m ³ /h q We reserve the right to make changes without prior notice

25 VHL hood piece, upper TGR-VHL SR SRI SRIP VHING / VHINP Sits around the roof weather protection, outer GISOL / GISOLP TGR UG weather protection, inner MG / MGL Vapour membrane piece, lower SR TGR-NA LKR SBG fastener Ducting This diagram shows pricipally all possible combinations of how the products can be joined together. Normally only one alternative is chosen and sometimes some options are omitted. For some combinations the needed size of a product isn't presented in the catalogue. In these cases the size needed most often can be produced and delivered to order. We reserve the right to make changes without prior notice

26 hood LHR H B+0 A B A + 0 Description LHR is a rectangular roof hood with ribs that is used for both outdoor air and extract air. The hood is supplied as standard in galvanised form, but is also available painted. LHR is supplied as standard with LS joint for guiding. When connecting to the roof through TGR, the special piece TGR-LHR must be used. (see page ). When connecting to the roof through TGR, the special piece TGR-LHR must be used. (see page ). A B H A B = Duct dimensions Number of ribs Free area m m kg through TGR 0 0 Size ,, ,, Ordering example Product Colour, if desired A in B in Duct Joining metods (Type ) Standard colours, see page. LHR S LS 0 We reserve the right to make changes without prior notice

27 hood LHR Technical data Outdoor air/extract air v [m/s] Δpt [Pa] [l/s] [m³/h] q We reserve the right to make changes without prior notice

28 LHR hood piece, upper TGR-LHR Sits around the roof TGFR TGR UG weather protection, inner MG / MGL SBGR Vapour membrane fastener piece, lower TGR-NA LKR SR Ducting This diagram shows pricipally all possible combinations of how the products can be joined together. Normally only one alternative is chosen and sometimes some options are omitted. For some combinations the needed size of a product isn't presented in the catalogue. In these cases the size needed most often can be produced and delivered to order. We reserve the right to make changes without prior notice

29 hood HVR B H α h Description Rectangular roof hood with angled upper side intended for outdoor air and extract air. HVR is designed for positioning above the outer roof on the roof through. The air runs both on the top- and downside of the hood. This is valid both for outdoor and extract air. The hood is free-draining downwards. Can also be supplied with a pest-proof mesh. HVR is manufactured as standard from galvanised steel sheet Z, but is also available in aluminium zinc AZ, stainless steel sheet.0, stainless acid-resistant steel sheet.0 or painted. HVR is available with different angles in order to be in harmony with the architectural design of the building. Sizes and are supplied with four twistable lifting and anchoring wire-loops. An individual anchoring eyelet must not be subjected to forces in excess of 00 N. A Size B h H α m kg ,0,0 Technical data 00 A Free area m² through TGR 0 0 Size Δp t [Pa] 0 Ordering example Product Size HVR [l/s] [m³/h] q Specify separately if the hood is to be supplied with a pestproof mesh from the factory and if a special angle is required. Standard colours, see page. We reserve the right to make changes without prior notice

30 HVR hood Sits around the roof TGR UG MG / MGL weather protection, inner Vapour membrane piece, lower TGR-NA SR LKR Ducting This diagram shows pricipally all possible combinations of how the products can be joined together. Normally only one alternative is chosen and sometimes some options are omitted. For some combinations the needed size of a product isn't presented in the catalogue. In these cases the size needed most often can be produced and delivered to order. We reserve the right to make changes without prior notice

31 hood HRR B H Description Rectangular roof hood intended for outdoor air and extract air. HRR is designed for positioning above the outer roof on the roof through. The air runs both on the top- and downside of the hood. This is valid both for outdoor and extract air. The hood is free-draining downwards. Can also be supplied with a pest-proof mesh. HRR is manufactured as standard from galvanised steel sheet Z, but is also available in aluminium zinc AZ, stainless steel sheet.0, stainless acid-resistant steel sheet.0 or painted. Sizes and are supplied with four twistable lifting and anchoring wire-loops. An individual anchoring eyelet must not be subjected to forces in excess of 00 N. A B H m Size kg ,0,00 Technical data Δpt [Pa] 00 0 A Free area m² through TGR 0 0 Size q [l/s] [m³/h] Ordering example Product Size HRR Specify separately if the hood is to be supplied with a pestproof mesh from the factory. Standard colours, see page. We reserve the right to make changes without prior notice

32 HRR hood Sits around the roof TGR UG MG / MGL weather protection, inner Vapour membrane piece, lower TGR-NA SR LKR Ducting This diagram shows pricipally all possible combinations of how the products can be joined together. Normally only one alternative is chosen and sometimes some options are omitted. For some combinations the needed size of a product isn't presented in the catalogue. In these cases the size needed most often can be produced and delivered to order. We reserve the right to make changes without prior notice

33 hood HKOMR C D H A B Description Combi-hood intended for outdoor air intake and the expelling of extract air. HKOMR is designed for location above the roof with or without a roof through. The intake and extract sections are separated with an internal wall. The intake section is protected against precipitation with a roof and pest-proof mesh. The extract section has a high-speed device and water-collection vessel. This part is also available with a pest-proof mesh. Air short circuit is prevented by the air intake s roof and the extract s highspeed device that ensures a long ejection distance. HKOMR is manufactured as standard from galvanised steel sheet Z, but is also available in aluminium zinc AZ, stainless steel sheet.0, stainless acid-resistant steel sheet.0 or painted. HKOMR is produced as standard for installation on Lindab s roof through TGKOMR, but can also be supplied with an adapted hose for guiding directly on to the duct. A B C D H Size Free area Size outdoor air m extract air m m kg 0, 0,00, Ordering example Product Size Alternatives that should be specified separately if required: With pest-proof mesh on the extract section With adapted hose for guiding directly into the duct. Standard colours, see page. HKOMR We reserve the right to make changes without prior notice

34 hood HKOMR Technical data Expelling velocity extract air 0 [m/s] 0 00 Outdoor air Δp t [Pa] 00 Δp t [Pa] [l/s] q [m³/h] Extract air 00 Δp t [Pa] [l/s] q [m³/h] We reserve the right to make changes without prior notice

35 hood piece, lower Ducting HKOMR TGKOMR TGR-NA TGR-NA SR SR LKR LKR This diagram shows pricipally all possible combinations of how the products can be joined together. Normally only one alternative is chosen and sometimes some options are omitted. For some combinations the needed size of a product isn't presented in the catalogue. In these cases the size needed most often can be produced and delivered to order. We reserve the right to make changes without prior notice

36 weather protection VHING/VHINP Ød 0 CCa. 0 α B Ød B Description The roof cover type VHING 0 and the accompanying duct collar is made of galvanized steel sheet. The roof cover types VHING are as standard designed with gray roof plate and delivered with duct collar of galvanized steel sheet. The roof plate is easily formed after the roof's shape. The accompanying collar is well tightened around the duct, and together with sealing mastic it makes a watertight ending around the roof. VHING can on order be delivered in black design (VHINS). Covers can also be delivered with roof plate made of galvanized sheet, designation VHINP. Note: VHING 0 is from factory sealed of around the cone. Max. roof angle a is. VHING 0 Ød nom VHING 0 / ØD nom A VHING 0 VHING -0 /- /- A nom B m kg 0,0 0,0 0 0, , , , ,0, ,0,00, ,00 A B C m kg , ,0 0 00, , , , , , , , , , , ,0 A 0 We reserve the right to make changes without prior notice

37 weather protection VHING/VHINP VHING ØD nom A B C m kg , ,0 0 00, , , , , , , , , , , ,0 We reserve the right to make changes without prior notice

38 weather protection UG A Description. UG Type A B for circular ducts 0 0 Ø 00 - Ø 0 0 Ø - Ø Ø 0 - Ø Ø 0 - Ø 0 00 Ø - Ø 00 B Ordering example Product Type UG 0 We reserve the right to make changes without prior notice

39 Vapour membrane MG Ø C L B R0 C Description The product is based on a special flexible -component rubber () that is integrated with a aluminium plate (). Used for sealing of the building envelope for all types of pipes and ducts, wich is lead trough a vapour barrier of roofing underlay. The product can be used as a roofing underlay or as a vapour barrier sheet, in the ridge as well as on the inclined roof area. You will also find screwholes () ready for fixed roofing underlay, concrete floor or floor structures. A special mounting instruction exists for this product. Mounting The membrane is easy to adjust; cut a hole that is 0 smaller than the duct dimension. The product can be used on roof pitches from 0- without any special precautions. The can be used in the ridge by bending it at the centre and adjusting it to the actual roof slope. The product can be assembled with the roofing underlay by means of double coated tape and/or perform adhesive. You will also find screw holes () ready for fixed roofing underlay, concrete floor or floor structures. Special designet for ceiling, shaft etc. used for ducts from Ø0 - Ø0 Type Max. duct measure / Ø B L C m kg MG , Standard Type Max. duct measure / Ø B L C m kg MG ,0 MG , MG 0, Ordering example Product Dimension MG 00 We reserve the right to make changes without prior notice

40 Vapour membrane MGL A B Description Made from a special flexible syntetic rubber and provided with tape with adhesive on both sides. Is used for sealing of the climate shield to all sorts of pipes and ducts, which passes through moisture barrier or roofing underlay. A special mounting instruction exists for this product. Type Max. duct dimension / Ø A B m kg MGL , MGL 0 0 0, MGL , MGL ,0 Ordering example Product Dimension MGL 0 We reserve the right to make changes without prior notice

41 Circular duct SR Ød* t Ød t l l Description Circular duct. Ducts are always produced locally and can therefore have different thicknesses and other specifications per country. The ducts can be produced both with and without click function (notches). Please specify when ordering. Ød std nom O πd m A πd ² / m t std * With outturned stiffening corrugation. l std ml std kg/m 0, 0,00 0, 000 0, 0 0, 0,00 0, 000 0, 0 0, 0,00 0, 000, 0, 0,0 0, 000, 00 0, 0,0 0, 000, 0 * 0, 0,0 0, 000, 00 * 0, 0,0 0, 000,0 *, 0,0 0, 000, Ordering example Product Dimension Ød Length l Type SR CLIC We reserve the right to make changes without prior notice

42 Circular duct SR Technical data [Pa/m] v [m/s] ød [] Δp t [l/s] [m /h] q We reserve the right to make changes without prior notice

43 Circular duct SR Technical data Special versions We can supply ducts with the following special designs: In intermediate dimensions, see page. Extra tight, with nitrile rubber seal in the lock seam In other sheet metal thicknesses Extra tight, with seam seal When extremely good sealing is required in the spiral seam, the ducts can also be supplied with a special rubber seal in the seam. This seal is very effective at stopping leakage of vegetable oils and greases, and most petroleum products including white spirit. Other sheet metal thicknesses If extra stability is needed in ducts, because of high negative pressure etc., they can be supplied with thicker sheet metal than standard. Remember that the thickness increase always reduces the inner diameter. Fittings for such special ducts must be specified separately and sometimes have to be made specially. Reinforcement corrugations Ducts of Ø0 and above are normally given stiffening corrugations to increase radial stiffness. Strength Positive pressure in case of high positive pressure, the seal moulding lips will first start to whistle. At considerably higher pressure, the joints between the ducts will be forced apart. If you manage to fix the s very well, the ducts will burst at their seams at even higher pressure. The high pressures needed for this to happen are not relevant to ventilation installations. Negative pressure In installations with high negative pressure, there is a risk that the ducts could collapse. This phenomenon is referred to as buckling, and can suddenly happen at the weakest point in the system. Buckling wanders along the duct, which can be completely flattened. The weakest point is frequently a "transport dent" on a duct. For this reason, only use undamaged ducts in systems which are close to the critical pressure! Sealing The ability of the seal moulding to seal is different from these pressures, and is noted on page. Diameter Sheet metal Collapsing pressure for duct SR , 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, Negative pressure Without stiffening corrugations 0 - -, -0 -,0 -, -0 -, -, With stiffening corrugations -,0-0, -,0 -, -,0 -, -, [kpa] , * -,0* * Collapse not achieved We reserve the right to make changes without prior notice

44 VH HN H HV HU VHA VHP VHL hood Sits around the roof SR VHING / VHINP weather protection, outer UG MG / MGL weather protection, inner Vapour membrane SR SBG fastener Ducting This diagram shows pricipally all possible combinations of how the products can be joined together. Normally only one alternative is chosen and sometimes some options are omitted. For some combinations the needed size of a product isn't presented in the catalogue. In these cases the size needed most often can be produced and delivered to order. We reserve the right to make changes without prior notice

45 Circular duct SRI l ØD Ød Description Circular duct. insulation. Ød nom 0 insulation. ØD m kg/m * Kurve 0 0,0 0, 0 00,0 00 0,0 0 00,0 00, 00, 00 0, 0 00, 00 0, Ød nom ØD m kg/m * Kurve 0 00,0,0 0 0, ,0 0, 00 00, 0, 00 00,0 0 0, 00 00, 0 Ordering example Product Insulation /0 Dimension Ød Lenght l SRI We reserve the right to make changes without prior notice

46 hood VH HN H HV HU VHA VHP VHL piece, upper AGIS Sits around the roof SRI VHING / VHINP weather protection, outer UG MG / MGL weather protection, inner Vapour membrane SBG fastener SR Ducting This diagram shows pricipally all possible combinations of how the products can be joined together. Normally only one alternative is chosen and sometimes some options are omitted. For some combinations the needed size of a product isn't presented in the catalogue. In these cases the size needed most often can be produced and delivered to order. 0 We reserve the right to make changes without prior notice

47 Circular duct SRIP l = 00 Ø D Ø d Description The roof type SRIP is used in with roof hoods type VHL, VHA and VHP, where there is both demands of condensation insulation and sound attenuation effect, plus a wish for a harmonic between roof and hood. SRIP is constructed around a perforated inner duct, an outer black painted spirally wounded duct with intermediate insulation and equipped with end cap at the bottom. It is recoended to fasten SRIP to roof beam. Use beam fixture type SBG. The standard length is 00. Lengths 00 and 000 in black, has to be ordered (no stock item). Ød ØD Fits with hood m SRIP VHL VHP VHA kg X X X, X X X, Technical data Ød nom Attenuation [db] for centre frequency [Hz] 0 00 k k k k Ordering example Product Dimension Ød Dimension ØD Length Colour SRIP S We reserve the right to make changes without prior notice

48 hood VH HN H HV HU VHA VHP VHL piece, upper AGIS Sits around the roof SRIP VHING / VHINP weather protection, outer UG MG / MGL weather protection, inner Vapour membrane SBG fastener SR Ducting This diagram shows pricipally all possible combinations of how the products can be joined together. Normally only one alternative is chosen and sometimes some options are omitted. For some combinations the needed size of a product isn't presented in the catalogue. In these cases the size needed most often can be produced and delivered to order. We reserve the right to make changes without prior notice

49 GISOL α H* Description Used for example in with roof hoods type VHL, VHA and VHP, where there is demands on insulation against heat or condensation creation plus a wish for a harmonic between roof and hood. Constructed around two spirally wounded ducts with intermediate insulation and equipped with end cap at the bottom. The roof plate is mounted on the duct and easy to fit to the roof s shape. It is recoended to fasten GISOL to roof beam, use beam fixture type SBG. Insulated with minimum 0 insulation material and thereby meets the standard DS. "Norm for brandtekniske foranstaltninger ved ventilationsanlæg". (Standard for fire technical regulations at ventilation plants) State the roof inclination at order. Max.. 0 will as standard always be delivered with galvanized steel sheet. Note: From factory sealed tight around the duct. Before the mounting of the the seal shall be checked for any damages from transportation and handling. After the mounting the seal shall likewise be checked for any damages from the mounting. The seal shall continously be checked for damages (advisably at least one time per year). Min.0. Ød MF ØD * H-measure = 00, this measure is only indicative, the height depends on the angle α Ød ØD Fits with hood: m GISOL VHL VHP VHA kg 0 0 X X X, 0 0 X X X, X X X, X X X, X, 0 0 X X, X,0 Ordering example Product Dimension Ød Dimension ØD Angle α GISOL 0 00 We reserve the right to make changes without prior notice

50 GISOLP α H* Description Used for example in with roof hoods type VHL, VHA and VHP, where there is demands on sound attenuation effect plus a wish for a harmonic between roof and hood. Constructed around a perforated inner duct, outer spirally wounded ducts with intermediate insulation and equipped with end cap at the bottom. The roof plate is mounted on the duct and easy to fit to the roof s shape. It is recoended to fasten GISOLP to roof beam, use beam fixture type SBG. Insulated with minimum 0 insulation material and thereby meets the standard DS. "Norm for brandtekniske foranstaltninger ved ventilationsanlæg". (Standard for fire technical regulations at ventilation plants). State the roof inclination at order. Max.. 0 will as standard always be delivered with galvanized steel sheet. Note: From factory sealed tight around the duct. Before the mounting of the the seal shall be checked for any damages from transportation and handling. After the mounting the seal shall likewise be checked for any damages from the mounting. The seal shall continously be checked for damages (advisably at least one time per year). Ordering example Product Dimension Ød Dimension ØD Angle α GISOLP 0 00 * H-measure = 00, this measure is only indicative, the height depends on the angle α Ød ØD Fits with hood: m GISOLP VHL VHP VHA kg 0 0 X X X,0 0 0 X X X, X X X, X X X, X X X,0 0 0 X X, X, Technical data Ød nom Min.0. Ød MF ØD Attenuation [db] for centre frequency [Hz] 0 00 k k k k We reserve the right to make changes without prior notice

51 hood VH HN H HV HU VHA VHP VHL piece, upper AGIS GISOL / GISOLP Sits around the roof UG weather protection, inner MG / MGL Vapour membrane SR SBG fastener Ducting This diagram shows pricipally all possible combinations of how the products can be joined together. Normally only one alternative is chosen and sometimes some options are omitted. For some combinations the needed size of a product isn't presented in the catalogue. In these cases the size needed most often can be produced and delivered to order. We reserve the right to make changes without prior notice

52 TGR TGR-OA Upper Ø0 0 C Ø Description Intended for to roof hood and roof fan. Available with various types of insulation for condensation or fire protection. Two fixing profiles are supplied to suit the root pitch. The upper in sizes 0- suits roof hood HN, for example. The upper in sizes is supplied without flange and is made so that you can use the enclosed mating flange from roof hood HF for instance. TGR can as addition be provided with two through-s for electric power and control voltage. TGR is manufactured as standard from galvanized steel sheet Z, but is also available in aluminium zinc AZ, stainless steel sheet.0, stainless acid-resistant steel sheet.0 or painted. The duct is supplied with RJFP joint for guiding. The C-measure of the upper (TGR-OA) shall fit the A-measure of the roof (TGR). TGR C 0 00 TGR-NA Lower B A 0 B Ød 0 The B-measure of the lower (TGR-NA) shall fit the B-measure of the roof (TGR). We reserve the right to make changes without prior notice

53 TGR Size A 0 insul. B Hole punching dimensions (A + 0 ) (A + 0 ) Ordering example 0 insul. C Weight kg 0 insul. 0 insul ,, , 0, Product Size Type of insulation Fire protection 0 Fire protection 0 Condensation 0 Internal cladding of insulation Zink plated steel Zink plated perf. steel Aluzink sheet metal AZ Aluzink sheet metal AZ perf. Stainl. acid-res. steel.0 Stainl. acid-res. steel perf..0 No internal cladding (Only applicable at condensation insulation) Stainless steel.0 External material Zink plated steel Aluzink sheet metal AZ Stainl. acid-res. steel.0 Stainless steel.0 TGR Accessories Upper TGR-OA Product Size Hood dimension Material Zink plated steel Aluzink sheet metal AZ Stainl. acid-res. steel.0 Stainless steel.0 Lower TGR-NA 0 Product Size Connection Measure Material Zink plated steel Aluzink sheet metal AZ Stainl. acid-res. steel.0 Stainless steel.0 Insulation thickness Upper only for roof hood VHL TGR-VHL Product Size Hood dimension Material Zink plated steel Aluzink sheet metal AZ Stainl. acid-res. steel.0 Stainless steel.0 Upper only for roof hood LHR TGR-LHR Product Size A B Material Zink plated steel Aluzink sheet metal AZ Stainl. acid-res. steel.0 Stainless steel.0 We reserve the right to make changes without prior notice

54 hood VH HN H HU VHA VHP HV VHL LHR HVR HRR piece, upper TGR-OA TGR- VHL TGR- LHR Sits around the roof TGR UG weather protection, inner MG / MGL Vapour membrane piece, lower TGR-NA SR LKR Ducting This diagram shows pricipally all possible combinations of how the products can be joined together. Normally only one alternative is chosen and sometimes some options are omitted. For some combinations the needed size of a product isn't presented in the catalogue. In these cases the size needed most often can be produced and delivered to order. We reserve the right to make changes without prior notice

55 Min. 0. lindab residential ventilation TGFR L = 00 End α 00 End a b 0 Description Rectangular roof, consisting of galvanized duct with 0 internal insulation, upon which the flexible roof tile is mounted. Delivered with grey flexible roof tile as standard. a b a Insulated with 0 insulation material and hence meets DS. "Norm for brandtekniske foranstaltninger ved ventilationsanlæg". Can to order and to extra cost be delivered with black roof tile and black top. Extra cost information on request. At mounting in with asphalt paper roofing the roof can be delivered with galv. steel sheet instead of the flexible roof tile. Galvanized steel sheet is factory sealed. Max. roof inclination is. *) At ordering the following shall be specified: Length of the roof (L) Flexible or galvanized roof tile Insulation Angle of the covering (a-side), max. Connections, e.g. standard LS or RJFP-profile Ordering example Product a b Other TGFR * We reserve the right to make changes without prior notice

56 LHR hood TGFR Sits around the roof UG weather protection, inner MG / MGL Vapour membrane SBGR fastener LKR Ducting This diagram shows pricipally all possible combinations of how the products can be joined together. Normally only one alternative is chosen and sometimes some options are omitted. For some combinations the needed size of a product isn't presented in the catalogue. In these cases the size needed most often can be produced and delivered to order. 0 We reserve the right to make changes without prior notice

57 TGKOMR C D * ** 0 00 Description adapted for combi-hood HKOMR. The is produced with 0 fire or condensation insulation. At to circular duct two lower s TGR-NA are used. The roof is manufactured as standard in galvanised steel plate, but is available in stainless steel sheet.0, stainless acid-resistant steel sheet.0, aluminium zinc AZ or painted. Two angle brackets are supplied for adaptation to the relevant roof incline. Sizes and dimensions according to drawing and table, but is available in extended version which is specified separately. The duct s are supplied with RJFP joints for guiding. Ordering example Product Size Type of insulation Fire protection 0 Condensation 0 Internal cladding of insulation Zink plated steel Zink plated perf. steel Aluzink sheet metal AZ Aluzink sheet metal AZ perf. Stainl. acid-res. steel.0 Stainl. acid-res. steel perf..0 No internal cladding (Only applicable at condensation insulation) Stainless steel.0 External material Zink plated steel Aluzink sheet metal AZ Stainl. acid-res. steel.0 Stainless steel.0 Standard colours see page. TGKOMR Size A Hole punching dimensions = (A + 0) (B + 0) * and ** are alternative positions for angle brackets TGKOMR-NA Lower The E-measure of the lower (TGKOMR-NA) shall fit the E-measure of the roof (TGKOMR). Accessories E B 0 A B C D E m kg , , , E Ød Lower TGKOMR-NA Product Size Connection measure Material Zink plated steel Aluzink sheet metal AZ Stainl. acid-res. steel.0 Stainless steel.0 E 0 0 We reserve the right to make changes without prior notice

58 hood HKOMR TGKOMR piece, lower TGKOMR-NA TGKOMR-NA SR SR LKR LKR Ducting This diagram shows pricipally all possible combinations of how the products can be joined together. Normally only one alternative is chosen and sometimes some options are omitted. For some combinations the needed size of a product isn't presented in the catalogue. In these cases the size needed most often can be produced and delivered to order. We reserve the right to make changes without prior notice

59 fastener SBG 0-0 Ø 0 Ød Description Fastener for fastening of ducts and roof s, which runs through floor separations, roof surfaces etc. The fasterner is made of electro galvanized pipe profile with duct holder in sheet metal profile. The fixing feet are made of sheet metal with bolt holes. To achieve optimal fit to roof beam etc. the pipe profile is constructed as a telescopic bar. Ød nom m kg 0,, Ordering example Product Dimension Ød SBG We reserve the right to make changes without prior notice

60 0 lindab residential ventilation fastener SBGR 00 0 A x B 0 Description Fastener for fastening of ducts and roof s, which runs through floor separations, roof surfaces etc. The fasterner is made of galvanized material. 0 0 A B Ordering example Product A B SBGR 0 0 We reserve the right to make changes without prior notice

61 lindab residential ventilation mounting parts SBG Description Mounting system for circular ducts. 0 0 Ød nom m kg 0, 00, 0,, Ordering example Product Dimension Ød SBG 0 We reserve the right to make changes without prior notice

62 Upper AGIS Ød H Ød ØD Description AGIS is the upper between the roof GISOL and a roof hood or roof fan with circular. Ød / Ød nom ØD nom H Ordering example Product Dimension Ød Dimension ØD AGIS 0 We reserve the right to make changes without prior notice

63 External wall grille YGC Ø 0 - Ø 0 Ø - Ø 0 E E ØD Ød ØD Ød Description Valve for outdoor air intake and extract air discharge. Designed with a fixed louvre. Ø 0 00 is equipped with net. Ø 0 0 can be delivered with net to order. Mesh width. Screws or nails connect to an external wall. Maintenance The grille should be removed to gain access to the duct. The external parts should be wiped with a damp cloth. Ød nom ØD * The grill has x Ø, screw holes on the side for mounting. ** The grill has x Ø,0 screw holes on the front for mounting. Ød >, no pre-drilled holes for mounting. A f (m ) = Free area. l E A f (m ) Weight kg 0 * 0, 0, 0 *,0, 0,00 0, *,, 0,00 0, 0 *,, 0,0 0, 00 * 0,, 0,00 0, 0 *,, 0,0 0, ** 0,, 0,0, l l Ordering example Product YGC 0 Type Size Ød Materials and finish Grille: ø0-00 Cast aluminium Grille: ø0-,0 Galvanised steel Standard finish: Untreated Can be supplied powder-coated. Contact Lindab s sales department for further information. We reserve the right to make changes without prior notice

64 External wall grille YGC Technical data Capacity Volumeflow, q [l/s] and [m /h], total pressure drop, Δp t [Pa], can be seen in the diagrams. Sound level in free field (/ spherical) The sound effect level L WA is shown in the diagram. For sound level at distance X [m], L A = L WA - K, see table below. X [m] 0 K [db] Ø [] Δ p t [Pa] Δ p t [Pa] L WA [db] [l/s] [m /h] q Ø [] L 0 WA [db] [l/s] [m /h] q 0 0 We reserve the right to make changes without prior notice

65 External wall grille H B A B - 0 / A - 0 A + 0 B + 0 / Description H is a louvred grille for installation in external walls. H is used for both fresh air intake and discharge. H is supplied as standard with a water stop at the rear edge, drip nose and bird netting. Maintenance The grille should be removed to gain access to the duct. The external parts should be wiped with a damp cloth. A x B 00 x x x x 00 Free area F (m ) 0,0 0,0 0, 0, 0,,,, Weight kg NOTE!: In with the design and dimensioning please be aware of the risk of water penetration and drift snow. Wind effects, especially in with grilles that are not connected to ducts, may result in water and snow being pressed through the grille; therefore please make sure to take any necessary precautions. The grille can be supplied in all dimensions. Max. A X B =,000 x,000. Min. A x B = 00 x 0 Ordering example Product H a bbb ccc Type Mounting 0 - Not prepared - Wall anchors - Screw holes - Insertion frame A - Measure B - Measure Materials and finish Grille: Standard finish: Aluminium Untreated Can be supplied powder-coated. Contact Lindab s sales department for further information. We reserve the right to make changes without prior notice

66 External wall grille H Technical data Capacity Volume flow q [l/s] and [m /h], total pressure drop p t [Pa] can be seen in the diagrams. Sound level in free field (/ spherical) The sound effect level L WA is shown in the diagram. For the sound level at distance X (m) L A = L WA - K, see table below. Distance x (m) 0 K [db] 0 Free area F (m ) F [m ]= (A-0) x (B-0) x 0. x - Pressure p t [Pa] Free area F [m Freier Querschnitt F[m²] ] LWA db(a) l/s m /h We reserve the right to make changes without prior notice

67 External wall grille VR B A Ød A + / B + C Description VR is a square louvred grille for installation in external walls. VR is used for both fresh air intake and discharge. VR is equipped as standard with a safe-seal circular. Maintenance The grille should be removed to gain access to the duct. The external parts should be wiped with a damp cloth. B + Ød Size A A + B C Free area F (m ) Weight kg 0 0 0,0, ,0, ,0, ,0,0 0 0,0,0 Ordering example Product VR 00 Type Size Materials and finish Grille: Standard finish: Aluminium Untreated Can be supplied anodized or powder-coated. Contact Lindab s sales department for further information. We reserve the right to make changes without prior notice

68 External wall grille VR Technical data Capacity Intake Discharge p t [Pa] p t [Pa] Size Size S u p p l y a i r LWA db(a) l/s m /h LWA db(a) l/s m /h 000 We reserve the right to make changes without prior notice

69 Take-off AVU L Ød Description Exhaust air stud with internal bird protection net. Standard angle is. Other angles are available to order. Standard design is galvanized sheet metal. Painted available to order (and extra cost). Fits duct SR. Ød nom L m kg 0 0, 0 0 0, , 0, 0 0 0, , 0 0,00,0 Ordering example Product Dimension Ød AVU We reserve the right to make changes without prior notice

SPIRO s world of fittings and accessories

SPIRO s world of fittings and accessories SPIRO s world of fittings and accessories SPIRO System/ Vent without rubber XCL TCPL XL BSL PSL BKCL0 BSL0 BFL0 BSFL0 BBKCL0 BFL0 BL0 BL0 REL RFL BFL BFL0 BL RCPL BFL BL0 RCFPL ILRL PSVL RCLL ILL TSTL

More information

Ventilation grille. Dimensions

Ventilation grille. Dimensions Ventilation grille B0 Dimensions B+/A+ B-/A- Description B0 is a rectangular aluminium grille with fixed horizontal bars. B0 is used for both supply and exhaust air, and is supplied as standard with springs

More information

Ceiling diffusers - visible

Ceiling diffusers - visible Ceiling diffusers - visible About Lindab Comfort and Design Product overview / symbols Theory Ceiling diffusers Ceiling diffusers - visible Plenum boxes Wall diffusers Nozzles Ventiduct Grilles Displacement

More information

GTH. Rectangular double deflection grille QUICK FACTS

GTH. Rectangular double deflection grille QUICK FACTS Rectangular double deflection grille QUICK FACTS For supply air Adjustable air deflectors Cleanable Installed using mounting frames FHB / FHA or commissioning box TRG Standard colour White RAL 900 -- alternative

More information

Floormaster DVQA, quarter-cylindrical terminals

Floormaster DVQA, quarter-cylindrical terminals Floormaster DVQA are quarter-cylindrical supply air terminals for positioning on the floor in a corner. The terminals are designed for displacement air handling in accordance with the Floormaster system

More information

ROL and ROL-S. climecon.fi

ROL and ROL-S. climecon.fi ROL and ROL-S The stylish and silent nozzle duct ROL is designed for rooms requiring large air volumes distributed evenly and without draught. The functional entity is completed by the ROL-S Adjustment

More information

VALLOX BLUESKY AIR DISTRIBUTION SYSTEM

VALLOX BLUESKY AIR DISTRIBUTION SYSTEM VALLOX BLUESKY AIR DISTRIBUTION SYSTEM FLEXIBLE AND EASY-TO-INSTALL AIR DISTRIBUTION SYSTEM Vallox BlueSky is an easy-to-install air distribution system that consists of a flexible ventilation duct made

More information

DRI. VARIZON Displacement unit with adjustable spread pattern

DRI. VARIZON Displacement unit with adjustable spread pattern VARIZON Displacement unit with adjustable spread pattern Quick facts Adjustable spread pattern and affected area Suitable for all types of rooms Cleanable Air volume measuring point Very simple to install

More information

Rectangular straight silencer

Rectangular straight silencer silencer DLD Dimensions b a l Description DLD has a conventional design with dimensions that not exceed the corresponding connection dimensions. The silencer can be manufactured in all standard duct sizes.

More information

IBIS. Duct diffuser with discs for supply air QUICK FACTS

IBIS. Duct diffuser with discs for supply air QUICK FACTS Duct diffuser with discs for supply air QUICK FACTS 0 flexible distribution pattern Suspended installation Easy installation Modular length: 00 mm Standard colour White RAL 900 -- alternative standard

More information

S u p p l y a i r h o o d J S I

S u p p l y a i r h o o d J S I Supply air hood JSI PAGE Table of Contents Product description & Product code Functioning principle, Parts Dimensions Positioning, Design Service Exhaust air Pressure loss & sound data Supply air 9 Supply

More information

Slot diffusers, Round duct diffusers IMP Klima 04 Slot diffusers Round duct diffusers 176

Slot diffusers, Round duct diffusers IMP Klima 04 Slot diffusers Round duct diffusers 176 B 0 LD- F 9. φ D H H a 8.5 5 5 A E 7 LD- F 8 8.5 9. 5 5 A 7 E LD-/ LD-/ LD- O/ LD- O/ LD- O/ LD- O/.5.5.5.5 LD-/ LD-/ LD-/ LD-/ LD-/ LD-/ 7.5 7.5 07 LD- O/ LD- O/ LD- O/ LD- O/ 5.5 5.5 5.5 5.5 9.5 87.5

More information

Jet nozzle, type DW-N2 Swivel jet nozzle, type DW-V2 Twist nozzle, type DW-V2-...-DR

Jet nozzle, type DW-N2 Swivel jet nozzle, type DW-V2 Twist nozzle, type DW-V2-...-DR , type DW-N Swivel jet nozzle, type DW-V Twist nozzle, type DW-V-...-DR DS 1 E 0.00/ and twist nozzle Preliminary remarks It is advisable to use nozzles to air-condition large spaces where the supply air

More information

VIREO Ceiling with ALX

VIREO Ceiling with ALX Square ceiling air diffuser with nozzles for supply air, with plenum box QUICK FACTS Flush design Suitable for VAV-applications Fast and easy installation Sealing ring, standard for spigot Energy efficient

More information

IBISTM. Duct diffuser with discs for supply air

IBISTM. Duct diffuser with discs for supply air TM Duct diffuser with discs for supply air Quick facts 0 flexible distribution pattern High induction capacity Suspended installation Easy installation Modular length: 00 mm Available in alternative colours

More information

NORDgrille Internal grilles

NORDgrille Internal grilles NORDgrille Internal grilles NORDgrille Contents RSP/RSV General grille RPS/RPV General grille RPSL/RPVL Floor grille RSO Transfer air grille RSL Transfer air grille RSM Transfer air grille RSI Exhaust

More information

09LD/GD. Air-Cooled Condensers/Air-Cooled Fluid Coolers. Nominal cooling capacity kw 09LD/GD 09GD

09LD/GD. Air-Cooled Condensers/Air-Cooled Fluid Coolers. Nominal cooling capacity kw 09LD/GD 09GD Air-Cooled Condensers/Air-Cooled Fluid Coolers 09LD/GD 09GD 09LD/GD Nominal cooling capacity 281-987 kw The 09LD air-cooled condensers are designed for refrigeration plants where a halogenated hydrocarbon,

More information

DKC. VARIZON Displacement unit with adjustable spread pattern

DKC. VARIZON Displacement unit with adjustable spread pattern VARIZON Displacement unit with adjustable spread pattern Quick facts Adjustable spread pattern and affected area Suitable for all types of room which require large airflows Simple installation Cleanable

More information

Grille. Min. - max. dimensions

Grille. Min. - max. dimensions Min. - max. dimensions 1 / 0 00 0 500 2 / 0 00 0 Description is a supply grille made from aluminum with curved adjustable blades, oriented 1-way or 2-way horizontal or vertical both for wall and ceiling

More information

FALCON High Flow. Circular ceiling air diffuser for supply air QUICK FACTS

FALCON High Flow. Circular ceiling air diffuser for supply air QUICK FACTS Circular ceiling air diffuser for supply air QUICK FACTS Ceiling air diffuser for supply air in rooms with high ceiling Manual operated change of spread direction as standard Motor operated change of spread

More information

ROLLING COUNTER SHUTTERS

ROLLING COUNTER SHUTTERS 500 ROLLING COUNTER SHUTTERS EXCEPTIONAL SECURITY AND AESTHETICS WAYNE DALTON COMMERCIAL DOOR SYSTEMS The Wayne Dalton Rolling Counter Shutter system provides the perfect solution for smaller openings

More information

SYSTEM 25 SYSTEM 50 AS SYSTEM 63 SYSTEM 75 SYSTEM 100. Alsident System 50. Antistatic (AS) Product Information

SYSTEM 25 SYSTEM 50 AS SYSTEM 63 SYSTEM 75 SYSTEM 100. Alsident System 50. Antistatic (AS) Product Information Alsident System 50 Antistatic (AS) Product Information . System 50 Antistatic General Information Product Specification Product description System 50 Antistatic Alsident System Airflow between 45-85 m

More information

Ideal protection for your electrics: häwa cable ducts

Ideal protection for your electrics: häwa cable ducts Ideal protection for your electrics: häwa cable ducts Well Conceived The häwa group has established itself as an innovative and highly competent supplier to machinery and facility equipment companies in

More information

Adjustable swirl diffuser PDZA TECHNICAL DATA

Adjustable swirl diffuser PDZA TECHNICAL DATA Adjustable swirl diffuser PDZA TECHNICAL DATA Adjustable swirl diffuser PDZA Adjustable ceiling swirl diffuser PDZA is intended for commercial and industrial buildings with a large room volume and high

More information

LOCAL EXTRACTORS. The ideal extractor for industrial environments. Pure advantage

LOCAL EXTRACTORS. The ideal extractor for industrial environments. Pure advantage The ideal extractor for industrial environments. New technology in combination with new materials and a focus on design gives Movex PR many new and important advantages: - Unique ease of maneuverability.

More information

NORDsilencers Ventilation system silencers

NORDsilencers Ventilation system silencers NORDsilencers Ventilation system silencers NORDsilencers 0 Contents General NRF 0/NRP 0 Silencer NRF 00/NRP 00 Silencer NRFB 0/NRPB 0 Silencer NRFB 00/NRPB 00 Silencer NMF/NMP Silencer NMFE/NMPE Silencer

More information

DCV-SP DCV-SP. DCV-SP Pressure control SPL Version B03 with actuator DA4/8 SMART DAMPERS & MEASURING UNITS. Product description AIN DIN AOUT DCV-SP

DCV-SP DCV-SP. DCV-SP Pressure control SPL Version B03 with actuator DA4/8 SMART DAMPERS & MEASURING UNITS. Product description AIN DIN AOUT DCV-SP DCV-SP Pressure control 24VAC + Communication DIN 24VAC + Communication AIN DCV-SP SMART DAMPERS & MEASURING UNITS Pressure control DCV-SP AOUT RELAY 1(14) Contents Page DCV-SP Introduction... 3 Functional

More information

AIR CONDITIONING PRODUCTS COMPANY

AIR CONDITIONING PRODUCTS COMPANY Quality Products for Air Movement Equipment AIR CONDITIONING PRODUCTS COMPANY all Shutter Backdraft Damper Ceiling Shutter Motorized Damper Fixed Louver Ga le Shutter Drainable Louver Supply Damper Fiberglass

More information

DESIGNED FOR THE FUTURE A NEW CONCEPT IN HATCH VENTILATION SYSTEMS

DESIGNED FOR THE FUTURE A NEW CONCEPT IN HATCH VENTILATION SYSTEMS DESIGNED FOR THE FUTURE A NEW CONCEPT IN HATCH VENTILATION SYSTEMS THINGS HAVE CHANGED, AND SO HAVE VENTILATION SYSTEMS. WALL SYSTEM HATCH SOLUTIONS ROOF SYSTEM A NEW CONCEPT IN HATCH VENTILATION SYSTEMS.

More information

Limanda. Technical data

Limanda. Technical data Polyamide hand held enclosures for data acquisition, MCR and automation engineering 2 sizes: 270 x 248 x 64 mm to 311 x 281 x 72 mm Large fitting area For installations and command devices mobile and stationary

More information

XENO 8. User & Installation Manual.

XENO 8. User & Installation Manual. XENO 8 User & Installation Manual www.audac.eu 2 Introduction 8 Full range loudspeaker cabinet The XENO series is a loudspeaker range specifically designed for fixed audio installations in modern environments,

More information

Building integrated duct systems

Building integrated duct systems Building integrated duct systes Residential ventilation Circular duct systes oods, grilles and transitions Dapers Silencers Valves and Grilles InCapsa InDoo ess doors essories 0 ir handling units Index

More information

Immersion Temperature Sensors

Immersion Temperature Sensors 1 782 1782P01 Symaro Immersion Temperature Sensors QAE2164 QAE2174 Active sensors for acquiring the water temperature in pipes and tanks Operating voltage AC 24 V or DC 13535 V Signal output DC 010 V or

More information

U V-Tu r b o h o o d s

U V-Tu r b o h o o d s U V-Tu r b o h o o d s Product description, Product code Parts Functioning principle Dimensions Exhaust air, pressure loss and sound data Supply air, pressure loss and sound data Distribution of supply

More information

robust advanced technology Accessories » for mobile and stationary Ringler suction systems

robust advanced technology Accessories » for mobile and stationary Ringler suction systems www.ringler-gmbh.de robust advanced technology Accessories» for mobile and stationary Ringler suction systems Valid from 01.01.2013 Information Dear Customer, This catalog gives you an important selection

More information

Grilles Type AR. AE for return air 1 / 1.3 / B / 1

Grilles Type AR. AE for return air 1 / 1.3 / B / 1 Grilles Type for return air 1 / 1 / B / 1 Contents Description Construction Cover Page 1 Contents 2 Description 2 Construction 2 Materials Standard Sizes Technical Data Technical Data Type Nomenclature

More information

Gas-actuated thermometer Stainless steel version Model 73

Gas-actuated thermometer Stainless steel version Model 73 Temperature Gas-actuated thermometer Stainless steel version Model 73 WIKA data sheet TM 73.01 for further approvals see page 15 Applications General process instrumentation in the chemical and petrochemical

More information

Viking Enviroclad Membrane

Viking Enviroclad Membrane 103 Viking Enviroclad Membrane STP110 Enviroclad Membrane Description Colour Thickness Width Length Weight m 3 Country of Origin STP100 Enviroclad White 1.14mm 3.05m 30.4m 155kg 0.20 USA STP110 Enviroclad

More information

LINE ARRAY SPEAKERS SR-S4LWP SR-S4SWP SR-EP4WP SR-PP4. EXTENSION PLATE (optional) PROTECTION PAD (optional) OPERATING INSTRUCTIONS

LINE ARRAY SPEAKERS SR-S4LWP SR-S4SWP SR-EP4WP SR-PP4. EXTENSION PLATE (optional) PROTECTION PAD (optional) OPERATING INSTRUCTIONS OPERATING INSTRUCTIONS LINE ARRAY SPEAKERS EXTENSION PLATE (optional) PROTECTION PAD (optional) SR-S4LWP SR-S4SWP SR-EP4WP SR-PP4 SR-S4SWP SR-S4LWP Thank you for purchasing TOA's Line Array Speakers and

More information

EcoTec SP tables and base cabinets

EcoTec SP tables and base cabinets Shapes and colours Tabletops and furniture surfaces Table superstructures, base cabinets and handles 30 mm panel with replaceable edge, Antistatic, light grey 30 mm panel with impact-resistant edge band

More information

lindab duct suspension & support system Duct suspensions & Support systems

lindab duct suspension & support system Duct suspensions & Support systems Duct suspensions & Support systems Content Duct suspensions & Support systems Duct suspension Duct suspension FB... UVH... 0 UVH0... 0 Threaded rod OSB 0...0 DRSN... 0 DRSNR... 0 Channels and channel brackets

More information

GALVANIZED-COATED SHELFING SYSTEM SHELVING FOR FOOD

GALVANIZED-COATED SHELFING SYSTEM SHELVING FOR FOOD ALVANIZED-COATED SHELFIN SYSTEM SHELVIN FOR FOOD ALVANIZED COATED SHELVIN ALVANIZEDRAL 7035 Entirely made of first grade steel and cold-profiled with galvanized steel according to the Sendzimir process

More information

Electrical cabinets for server and LAN. 42 Lafer

Electrical cabinets for server and LAN. 42 Lafer Lafer@ck Electrical cabinets for server and LAN 42 Lafer Lafer@ck Lafer. Around you Lafer@ck Lafer 43 Lafer@ck Electrical cabinets for server and LAN They are designed for all information systems and data

More information

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency. Draft

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency. Draft echnical data sheet LH24A-MF2-P Parmeterisable linear actuator for adjusting dampers and slide valves in technical building installations Air damper size up to approx. m² Actuating force 5 N Nominal voltage

More information

NEOSTAR AXIAL FAN CONDENSER COMMERCIAL AND INDUSTRIAL RANGE HFC. 18 > 1240 kw. NEOSTAR POWER The choice of performance and low space requirement.

NEOSTAR AXIAL FAN CONDENSER COMMERCIAL AND INDUSTRIAL RANGE HFC. 18 > 1240 kw. NEOSTAR POWER The choice of performance and low space requirement. AXIAL FAN CONDENSER COMMERCIAL AND INDUSTRIAL RANGE Hard Discount - Supermarkets - Hypermarkets Refrigerated storage and transit stocking - Dispatch centres Food processing - Canteen kitchens HFC 18 >

More information

Before attempting to connect or operate this product, please read these instructions carefully and save this manual for future use.

Before attempting to connect or operate this product, please read these instructions carefully and save this manual for future use. Operating Instructions Ceiling Mount Bracket Model No. WV-Q175 WV-Q175E Before attempting to connect or operate this product, please read these instructions carefully and save this manual for future use.

More information

VOLUME II B CIVIL, STRUCTURAL & ARCHITECTURAL WORKS

VOLUME II B CIVIL, STRUCTURAL & ARCHITECTURAL WORKS SHEET 1 OF 5 VOLUME II B CIVIL, STRUCTURAL & ARCHITECTURAL WORKS SECTION - D GENERAL TECHNICAL SPECIFICATION ROOLING STEEL SHUTTERS/GRILS Bharat Heavy Electricals Limited Project Engineering Management

More information

ALPHA Small Distribution Boards SIMBOX 63/SIMBOX WP

ALPHA Small Distribution Boards SIMBOX 63/SIMBOX WP ALPHA Small Distribution Boards SIMBOX 63/SIMBOX WP SIMBOX 63 /4 Introduction /5 Flush mounting distribution boards /6 Hollow-wall distribution boards /7 Surface mounting distribution boards /7 Hood-type

More information

XS Roof Type Overview

XS Roof Type Overview XS Roof Type Installation Overview XS Linked CABLE system ON STEEL ROOF Rigorous testing has proven the strength and resistance of the XS Linked Cable System on a steel roof. The main components of an

More information

Room sensors QFA4160 QFA41 D AQF4150 AQF3153. Symaro. for relative humidity and temperature with calibration certificates

Room sensors QFA4160 QFA41 D AQF4150 AQF3153. Symaro. for relative humidity and temperature with calibration certificates 1 859 1859P01 1859P02 1859P04 QFA4160 QFA41 D AQF4150 AQF3153 Symaro Room sensors for relative humidity and temperature with calibration certificates QFA41 Operating voltage AC 24 V / DC 13.5...3 Signal

More information

Duct Sensors. Building Technologies HVAC Products. Symaro. for relative humidity and temperature with calibration certificates

Duct Sensors. Building Technologies HVAC Products. Symaro. for relative humidity and temperature with calibration certificates 1 883 1883P01 1883P02 QFM4160 AQF4150 Symaro Duct Sensors for relative humidity and temperature with calibration certificates QFM41 Operating voltage AC 24 V / DC 1353 Signal output DC 010 V / 420 ma for

More information

BAR GRILLE TYPE: A-600

BAR GRILLE TYPE: A-600 Tel: Sales 0 I Web: www.grada.co.uk TYPE: A00 Installation dimensions AC00 AA00* / AD00 + GR00 0. (+0)(L+0)* / (+0)(L+0) (0)(L0) 0* () (L) ( L) AB00* / AE00 + GR00 (+0)(L+0)* / (+0)(L+0) (0)(L0) 0* ( L)

More information

Box Fans.

Box Fans. Box Fans www.systemair.pt Structure Description MVE/MVENT The D covers an airflow range between m/h and.000 m/h, suitable for indoor and outdoor installation. The DD covers an airflow range between 0 m/h

More information

TopConsole system TP. Combination options 1-part 2-part 3-part. System accessories Page 537 Monitors, keyboards From page 796 Climate control Page 389

TopConsole system TP. Combination options 1-part 2-part 3-part. System accessories Page 537 Monitors, keyboards From page 796 Climate control Page 389 opconsole system P System accessories Page 537 Monitors, keyboards From page 796 Climate control Page 389 Enclosure: Sheet steel 1.5 mm Door and console cover: Sheet steel, 2.0 mm, all-round foamed-in

More information

Circular and semi-circular displacement outlet Q-Z...

Circular and semi-circular displacement outlet Q-Z... and semi-circular Q-Z... DS 0 E 0.0 and semi-circular Preliminary remarks The circular is installed free standing in the room or - preferably the semicircular model - placed in front of a wall or pillar

More information

Single action door patch fittings

Single action door patch fittings Single action door patch fittings The flexible system for all installation situations. CONTENTS Technical details - 5 Materials and surface finishes Product information Patch fittings / none rebated frame

More information

IP degrees of protection. Degrees of mechanical shock protection IK conforming to the CEI EN Standard

IP degrees of protection. Degrees of mechanical shock protection IK conforming to the CEI EN Standard Definition of IP degree of protection, IK degree of mechanical shock protection and self-extinguishing degree of protection IP degrees of protection 1 st DIGIT: PROTECTION AGAINST SOLID BODIES 2 nd DIGIT:

More information

Limanda. Technical data

Limanda. Technical data Polyamide hand held enclosures for data acquisition, MCR and automation engineering 2 sizes - 270 x 248 x 64 mm to 311 x 281 x 72 mm Large fitting area For installations and command devices mobile and

More information

Model PS20D Watt Amplified Horn Loudspeaker. Installation and Operating Instructions

Model PS20D Watt Amplified Horn Loudspeaker. Installation and Operating Instructions Model PS20D630 20 Watt Amplified Horn Loudspeaker Installation and Operating Instructions DOCUMENT NUMBER PS20D630/OEM/01 REVISION 1.2 8 December 2008 TABLE OF CONTENTS SAFETY NOTES Page 3 SYSTEM OVERVIEW

More information

Overview of types. Technical data

Overview of types. Technical data echnical data sheet SH2A-MF.. Multifunctional linear actuators for adjusting air dampers and slide valves in ventilation and air-conditioning systems for building services installations For air control

More information

OTHER FLAGPOLES 3 Other flagpoles FLAGMORE ACTION / Flagpole 6-2 meters Flagpole for temporary in ground installation. Delivered complete with cleat holes. Cleat holes on,5 m from the bottom or at any

More information

FILTER NAME CONSTRUCTION FEATURES APPLICATIONS ORDER CODE MEMBRANE Body: polycarbonate Filter: PTFE membrane

FILTER NAME CONSTRUCTION FEATURES APPLICATIONS ORDER CODE MEMBRANE Body: polycarbonate Filter: PTFE membrane Filter Caps for Humidity and Dewpoint Transmitters with probe 12 mm (0.47 ) The right choice of appropriate filter cap is essential for best long term performance in the application. For assistance please

More information

BELLOWS COVERS AND.

BELLOWS COVERS AND. BELLOWS AND COVERS www.joycedayton.com BELLOWS AND COVERS REDUCE EXPENSIVE MAINTENANCE AND DOWN TIME Protect your Equipment Investment When bellows and covers are fitted to machinery, expensive maintenance

More information

Catalogue 2016 HOSE TECHNOLOGY. Fittings, Valves and Accessories. Schauenburg Hose Technology Group

Catalogue 2016 HOSE TECHNOLOGY. Fittings, Valves and Accessories. Schauenburg Hose Technology Group Catalogue 2016 HOSE TECHNOLOGY Fittings, Valves and Accessories Schauenburg Hose Technology Group PREAMBLE The new fittings and accessories range of APD Petzetakis Schlauchtechnik GmbH Quality and reliability

More information

1/2 Introduction. SIMBOX LC 1/7 Introduction 1/8 Flush-mounting and surfacemounting. 1/9 Dimensional drawings

1/2 Introduction. SIMBOX LC 1/7 Introduction 1/8 Flush-mounting and surfacemounting. 1/9 Dimensional drawings Siemens AG 200 ALPHA SIMBOX Small Distribution Boards /2 Introduction /2 Introduction /3 Flush-mounting and hollow-wall distribution boards /4 Hood-type distribution boards /5 Accessories /6 Dimensional

More information

Flow VA 500/

Flow VA 500/ VA 500/ 520 Verbrauch 79 What are the advantages of the flow measuring technology of CS Instruments? 1) 500 is mounted by means of a standard 1/2 ball valve. During mounting and dismounting the safety

More information

TYPE 4/12 PREMIER SERIES

TYPE 4/12 PREMIER SERIES Type 4 / 12 Enclosures TYPE 4/12 PREMIER SERIES ENCLO- Contemporary Contemporary Design Design Seamless Seamless Foam-In-Place Foam-In-Place Gasketing Gasketing Utility Utility Brackets Brackets for for

More information

37 Polished Stainless Steel

37 Polished Stainless Steel 80 BAWER 81 82 1,5 mm SERIES BAWER 37 37 Polished Stainless Steel Example of fitting-out Stainless Steel AISI 304/X5CrNi18-10/1.4301-2R Thickness mm 1,5 Mechanical resistance; water resistance Laser and/or

More information

Filter Fan Unit LIGHT

Filter Fan Unit LIGHT Filter Fan Unit LIGHT Type LIGHT EC Technical Concept Technical Concept Filter Fan Unit LIGHT Product Description Filter Fan Units (FFUs) from M+W Products are designed to provide clean air to individual

More information

Emergency Luminaire for Fluorescent Lamps Series EXLUX 6009

Emergency Luminaire for Fluorescent Lamps Series EXLUX 6009 > As wall, ceiling and pendant light fitting or pole mounted light fitting > Version with 2 lamps: 18 W and 36 W > Central locking > All-pole disconnection via N/C switch when opening light fitting or

More information

Combi-System. Composition pipe Copipe

Combi-System. Composition pipe Copipe Combi-System Composition pipe Copipe no. Composition pipe Copipe white rolls DN 10 x 2.0 mm length per roll 50 m 150 10 54 length per roll 100 m 150 01 54 length per roll 200 m 150 02 54 DN 12 16 x 2.0

More information

CEILING SWIRL DIFFUSER MLD

CEILING SWIRL DIFFUSER MLD CEILING SWIRL DIFFUSER MLD Proektasi Makriyianni Ano Ilioupoli P.O.BOX: 6 P.C.: 1 Thessaloniki GREECE Tel.: +0 687 FAX: +0 68047 WEB SITE: www.aerogrammi.gr E-MAIL: info@aerogrammi.gr MLD CEILING ROUND

More information

Technical Concept. Filter Fan Unit LIGHT. Type LIGHT AC Type LIGHT EC

Technical Concept. Filter Fan Unit LIGHT. Type LIGHT AC Type LIGHT EC Technical Concept Filter Fan Unit LIGHT Type LIGHT AC Type LIGHT EC Filter Fan Unit LIGHT Technical Concept Product Description Filter Fan Units (FFUs) from M+W Products are designed to provide clean air

More information

Round Louvers. Adapters for , 45, 47 & 86. XV.3. Air Distribution

Round Louvers. Adapters for , 45, 47 & 86. XV.3. Air Distribution Air Hose 23-0102 2 Low friction, non collapsible, sold in length of 47 (1200 mm) 23-0104 2.5 Low friction, non collapsible, sold in length of 47 (1200 mm) 23-0015 23-0020 23-0025 23-0035 23-0040 2 Collapsible

More information

HV-STYLVENT Series WALL OR WINDOW EXTRACT FANS HV-STYLVENT. Wall or window extract fans. Elegant design harmonising with any environment

HV-STYLVENT Series WALL OR WINDOW EXTRACT FANS HV-STYLVENT. Wall or window extract fans. Elegant design harmonising with any environment WALL OR WINDOW EXTRACT FANS Series Complete range of axial flow fans for wall or window mounting applications. All the fans are supplied with tough ABS plastic grilles, shutter and single phase V- 5Hz

More information

Emergency stops and Pilot devices

Emergency stops and Pilot devices Emergency stops and Pilot devices IMAGES DESIGNATION ARTICLE NUMBER DESCRIPTION INCA INCA 1 Tina 2TLA030054R0000 Emergency stop button for panel mounting, 22.5 mm holes, Tina adaption unit included for

More information

FMC cartridge filter. Compact cartridge filter for solving dust problems within a wide range of industries

FMC cartridge filter. Compact cartridge filter for solving dust problems within a wide range of industries Compact cartridge filter for solving dust problems within a wide range of industries The FMC cartridge filter series offers many operational benefits thanks to its compact design and patented UniClean

More information

HV-STYLVENT Series WALL OR WINDOW EXTRACT FANS. Wall or window extract fans HV-STYLVENT. Elegant design harmonising with any environment

HV-STYLVENT Series WALL OR WINDOW EXTRACT FANS. Wall or window extract fans HV-STYLVENT. Elegant design harmonising with any environment WALL OR WINDOW EXTRACT FANS HV-STYLVENT Series 688 679 Shutter Reversible Natural ventilation position Complete range of axial flow fans for wall or window mounting applications. All the fans are supplied

More information

Type 4X S.S. Disconnect Enclosures

Type 4X S.S. Disconnect Enclosures 201 SAGINAW CONTROL & ENGINEERING STOCK PRICE LIST Saginaw Control & Engineering s Type 4X S.S.Disconnect Enclosures are designed to work in a wide range of environments indoors or outdoors, and house

More information

STR-3 STANDARD 3-PHASE 230 VAC TRANSFORMER CONTROLLER. Mounting and operating instructions

STR-3 STANDARD 3-PHASE 230 VAC TRANSFORMER CONTROLLER. Mounting and operating instructions STANDARD 3-PHASE 230 VAC TRANSFORMER CONTROLLER Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS 3 PRODUCT DESCRIPTION 4 ARTICLE CODES 4 INTENDED AREA OF USE 4 TECHNICAL DATA

More information

Declaration of Performance (DOP)

Declaration of Performance (DOP) Declaration of Performance (DOP) No. 9174 015 DOP 2018-01-08 1. Unique identification code of the product-type: Multi-wall chimney system type DW-ECO-TITAN according to 2. Type, batch or serial number

More information

Series 75. Steel Roller Shutters

Series 75. Steel Roller Shutters Roller Shutters consist of individual interlocking steel slats, providing high strength security for commercial and industrial applications such as factories, loading docks, workshops and warehouses. FEATURES

More information

Standard Frame Axial Fans

Standard Frame Axial Fans Quick reference guide Standard Frame Axial Fans 2007 Edition about Axair Fans UK Application knowledge : 20 years experience in air movement; from fume handling to refrigeration; from small electronic

More information

Han PCB termination. Han-Fast Lock PCB adapter for Han DD PCB adapter for Han DDD module

Han PCB termination. Han-Fast Lock PCB adapter for Han DD PCB adapter for Han DDD module Han termination Contents Page Han-Fast Lock... 20.11 adapter for Han DD... 20.13 adapter for Han DDD module... 20.16 adapter for Han 40 A Axial module... 20.18 adapter for Han E... 20.20 adapter for Han

More information

Service poles for industrial applications

Service poles for industrial applications Service poles for industrial applications Ready to go. The ISS basic profile Our industry service poles bundle power, data and compressed air in a compact and robust manner. This means relocations, for

More information

Weatherproof enclosures for all corrosive environments

Weatherproof enclosures for all corrosive environments IP 66 MRIN INETS N ENLOSURES >>> Marina cabinets polyester - IP 66 - IK 10 www.klinkmann.com Weatherproof enclosures for all corrosive environments 362 56 362 76 Technical characteristics (p. 289) IP 66

More information

Type 4 Disconnect Enclosures

Type 4 Disconnect Enclosures 143 SAGINAW CONTROL & ENGINEERING STOCK PRICE LIST Saginaw Control & Engineering s are designed to work in a wide range of environments indoors or outdoors, and will house most standard types of disconnects

More information

R u b b e r d i s t r i b u t o r

R u b b e r d i s t r i b u t o r Rubber distributor The modular rubber distributor series We live in a fast-moving time. It is also frequently necessary to make modifications to power distribution systems. Power distributors used in industrial

More information

High Security Roller Shutters. factories retail shops loading bays warehouses industrial units

High Security Roller Shutters. factories retail shops loading bays warehouses industrial units High Security Roller Shutters Where higher levels of security is a main concern, the LPS1175 approved Centurion Shutter resists attempts at forced entry from SR1 right up to SR4 to combat the most determined

More information

Safety mats. sensing the future. Electrical surface switches for safe activation and deactivation of machines, devices and automatic doors

Safety mats. sensing the future. Electrical surface switches for safe activation and deactivation of machines, devices and automatic doors sensing the future Electrical surface switches for safe activation and deactivation of machines, devices and automatic doors Reliable, robust, low-maintenance System is simple to install Surface switch

More information

roller shutters ALUMINIUM ROLLER SHUTTERS FOR SPECIAL VEHICLES

roller shutters ALUMINIUM ROLLER SHUTTERS FOR SPECIAL VEHICLES roller shutters ALUMINIUM ROLLER SHUTTERS FOR SPECIAL VEHICLES ROLLER SHUTTERS INTRODUCTION The main target of company SRS is to offer competence and reliability to the customers in the production of aluminium

More information

See «Overview of types» 90 s / 60 mm 150 s / 100 mm Manuelle Auslösung der Adaption durch Drücken der Taste «Adaption» oder mit dem PC-Tool

See «Overview of types» 90 s / 60 mm 150 s / 100 mm Manuelle Auslösung der Adaption durch Drücken der Taste «Adaption» oder mit dem PC-Tool echnical data sheet LHA-MF..-P Multifunctional linear actuators for adjusting air dampers and slide valves in ventilation and air-conditioning systems for building services installations For air control

More information

kyalfa V- VDD/VDD6 General Contents

kyalfa V- VDD/VDD6 General Contents General Contents. kyalfa V- VDD/VDD6 ky General Contents General Features A dry cooler is a forced convection air-cooled fluid cooler, designed for outdoor installation. Air is forced over the finned coil

More information

Flatwall. Aesthetic value and functional integration for home automation

Flatwall. Aesthetic value and functional integration for home automation Flatwall Aesthetic value and functional integration for home automation 2 MyHOME FLATWALL Index 2-13 General features 14-33 General rules for installation 34-39 Catalogue MyHOME FLATWALL 240-270 2 MyHOME

More information

IP Enclosures Product Overview 2015

IP Enclosures Product Overview 2015 IP Enclosures Product Overview 2015 ENGINEERING COMPUTER SERVICES LTD Wall Mounted Electrical Enclosure Systems IP Enclosures is a premium brand of high quality wall mounted electrical enclosures and accessories.

More information

SYSTEM WORLD PRODUCT INFO

SYSTEM WORLD PRODUCT INFO SYSTEM WORLD PRODUCT INFO August 208 System case.. System Case Configuration.. Width x depth x height (inches).56 x 0.62 x 3.3 inches Number of System Boxes Material Lid Type Art. No. Empty* ABS Black

More information

Argenta W A L L M O U N T I N G M E T A L C A B I N E T S

Argenta W A L L M O U N T I N G M E T A L C A B I N E T S Argenta W A L L M O U N T I N G M E T A L C A B I N E T S The ARGENTA Series is a group of metal enclosures used to house on the inside electrical or electronic switchgear, controlgear and equipment necessary

More information

LED LIGHT PANEL QUADRANT SMD

LED LIGHT PANEL QUADRANT SMD LED LIGHT PANEL QUADRANT SMD WU-M-573 LED LIGHT PANEL QUADRANT SMD LED MODULES FOR HIGH-END RESIDENTIAL LIGHTING WU-M-573 Typical Applications Built-in luminaires/general illumination Large round ceiling

More information

Incorporating V2.2. Product spec >>> > Series CD - Ceiling diffusers

Incorporating V2.2. Product spec >>> > Series CD - Ceiling diffusers Incorporating V2.2 Product spec >>> > Series CD - Ceiling diffusers Diffusers Ceiling (Louvre faced) Recommended for: Ceiling Supply Overview Excellent diffusion characteristics CD4 tile replacers normally

More information

Panel Enclosures. Wall-Mount Enclosures Type 12 Premier Series Double-Door with Quarter-Turn Latches Data Sheet

Panel Enclosures. Wall-Mount Enclosures Type 12 Premier Series Double-Door with Quarter-Turn Latches Data Sheet Panel Enclosures Wall-Mount Enclosures Type 12 Premier Series Double-Door with Quarter-Turn Latches Data Sheet Construction Enclosure and door are fabricated from code gauge steel (see page 153) All continuous

More information