BARION atm Manual. Combination vacuum meter for measurements from atmosphere to UHV.

Save this PDF as:
 WORD  PNG  TXT  JPG

Size: px
Start display at page:

Download "BARION atm Manual. Combination vacuum meter for measurements from atmosphere to UHV."

Transcription

1 BARION atm Manual Combination vacuum meter for measurements from atmosphere to UHV

2 0 Inhaltsverzeichnis BARION atm Manual 07 / 2016

3 VACOM combination vacuum meter for measurements from atmosphere to UHV BARION atm Contact: 07 / / BARION atm Manual COLDION Bedienungsanleitung

4 0 Contents 0 Table of contents General information Product description Storage General regulations and warranty CE-derclaration of conformity Safety Observance of the operating instructions Basic safety information Signs and symbols Getting started Unpacking Check for damage Scope of delivery Acclimatisation Connection and installation Description of the RS232 interface Conversion of the voltage or current at the analogue interface Operation General information Safety information Adjustment Setpoints Maintenance Cleaning and care Firmware update Troubleshooting Return / disposal BARION atm Manual

5 0 Contents A A.1 Technical data...16 A.2 Accessories...17 A.3 Communication with the BARION atm...17 A.3.1 ATMION protocol...17 A.3.2 Port settings...18 A.3.3 Command set...18 A.3.4 Pressure output via RV...19 A.3.5 Calculation of the input values for specifying the setpoint...19 A.3.6 Meaning of the status bit...20 A.3.7 Meaning of the control bit...21 A.4 Legally binding Declaration of Contamination...21 A.5 VACOM Protocol (quick introduction)...22 A. 5.1 Setups...22 A. 5.2 Entering instructions...23 A For all devices valide commands...24 A Instructions for device class of pressure gauges...25 A Instructions for device class of ion getter pumps (IGP)...26 A Special instructions for GAPAS...28 A Special instructions for BARION atm...29 A Control by the way of +24 V control signals Notes...33 BARION atm Manual 5

6 1 General information 1.1 Product description The wide-range vacuum gauge BARION atm allows a pressure measurement from 5 x mbar to atmosphere. This is made possible by the combination of a heat loss vacuum gauge, also known as Pirani, and a Bayard-Alpert vacuum meter. 1.2 Storage The sensor and the control electronics must be stored in a dry and dust-free environment. The flange must be covered with a plastic cap. The ambient temperatures for the storage must only be between 0 C and 40 C. In addition, the environment must be non-condensing and must have an accordingly low humidity. 1.3 General regulations and warranty A warranty of one year is assumed for the proper functioning of the device. During this period, material and manufacturing defects are eliminated free of charge. Normal wear as well as malfunctions caused by improper use (this also includes severe contamination of the sensor) are not covered by warranty. The manufacturer does not assume any warranty for alterations to the device beyond the work listed in the manual. The costs for returning are borne by the customer. Return is made in the original packaging. We reserve the right to decide on replacement or repair after examination in our premises. 1.4 CE-declaration of conformity Within the CE-declaration of conformity the following directives, standards and guidelines have been used: 2004 / 108 / EG EN ( ) EN ( ) EG guideline for electromagnetic compatibilityt Safety requirements for electrical equipment for measurement, control, and laboratory use Industrial, scientific and medical equipment; Limits and methods of measurement EN ( ) Electromagnetic compatibility (EMC) - Limits for harmonic current emissions EN ( ) Electromagnetic compatibility (EMC) - Limits Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply EN ( ) electrical equipment for measurement, control, and laboratory use EMC requirements 2014/ 53/ EU Guideline for radio installation 6 BARION atm Manual 07 / 2016

7 2 Safety 2.1 Observance of the manual The BARION atm is delivered ready for operation. Please observe the notes for handling the measuring device listed in this manual. Any damage to the product caused by improper handling will void the warranty. 2.2 Basic safety information With regard to installation, maintenance and repair measures, observe the specified protection provisions. Voltages exceeding 30 V AC or 60 V AC are considered to be hazardous live according to EN Replacing the damaged component must be performed at VACOM. Unauthorised interference will void any warranty claims. All work on the device must only be performed by trained personnel! Improper use may lead to serious injuries or death! 2.3 Signs and symbols NOTE, DANGER or WARNING: Information on preventing any kind of personal or material damage. DANGER: Information on preventing any kind of personal or material damage caused by electrical influences. NOTE: General notes on further information or related articles. 07 / 2016 BARION atm Manual 7

8 3 First steps 3.1 Unpacking Check for damage Before unpacking the product, check the package for visual damage. If the package and thus also the operating device is damaged, contact us at Scope of delivery The scope of delivery includes one BARION atm, consisting of control electronics and sensor. The following fi gures show the rears of the sensor and the control electronics after taking apart the BARION atm. Rear of control electronics a b c d Mains connection RS232 communication Signal lamp for setpoint control Signal lamp for current mode Rear of sensor a Pirani sensor b 1, 2 Filament 1, 2 c d e Filament Common Anode Collector 8 BARION atm Manual 07 / 2016

9 3 First steps The signal lamp for the current mode [c in Fig. 1] indicates in which mode the BARION atm is currently operated (see site 9). The signal light d shows wether the setpoint is active or inactive. Signal light Colour Meaning c (mode) Green, lighting Hot cathode active c Green, flashing slowly Pirani active c Green, flashing rapidly Degas active c Yellow, lighting Internal reboot Do not cancel in this state! If this state lasts longer than one minute, please contact your customer adviser at VACOM. c green/red, flashing Defective filaments c red, flashing Defective Pirani or control electronics d (setpoint) off SP1 off/ SP2 off d yellow, glowing SP1 active/ SP2 off d green, glowing SP1 off/ SP2 active d yellow, flashing SP1 active/ SP2 active Acclimatisation After unpacking and before the first start, the device should be brought to room temperature for some hours for acclimatisation. This way, electrical short-circuits and thus the failure of the device caused by condensation can be prevented. 07 / 2016 BARION atm Manual 9

10 4 Connection and installation The sensor is conventionally assembled to a KF25 flange. In order to guarantee a clean vacuum and thus an optimum pressure measurement, we recommend the use of gloves. If the sensor is connected, it can be connected to a PC via a RS232 cable. The BAA adapter cable (not included in the scope of delivery, see A.2) can be used for the connection to a VMG read or an MVC3-A. Moreover, the communication with BARION atm is optionally possible via fieldbus. In case of communicating with a PC or via fieldbus, the power supply must be connected. 4.1 Description of the RS232 interface The RS232 interface allows communication with the outside world. In addition to RxD / TxD connections for communicating via RS232, the interface has inputs for the power supply, an analogue output, which supplies a voltage proportional to the pressure or a current proportional to the pressure, and three setpoint outputs. 1) Analogue output 2) RxD 3) TxD 4) + 24 V DC 5) GND 6) Analogue GND 7) Setpoint 1 (RTS), max. 30 V / 0.5 A 8) Setpoint 1 (CTS) 9) Setpoint 2 OC, max. 30 V / 0.5 A 4.2 Conversion of the voltage or current at the analogue interface During the readout of the pressure from the BARION atm via an analogue interface, the following conversions must be observed: Type of readout Voltage (0 10 V) Conversion factor V / Dekade Maximum (V or ma / mbar) Minimum (V or ma / mbar) V / 1000 mbar V / mbar Current (0 20 ma) ma / Dekade ma / 1000 mbar ma / mbar Current (4 20 ma) ma/ Dekade ma/ 1000 mbar ma/ mbar An error signal is generated above the maximum and below the minimum. 10 BARION atm Manual 07 / 2016

11 5 Operation Any operation is realised via a connection to the PC or to the display (a VMG read or an MVC3-A). The communication takes place regularly via the VACOM protocol; however, the ATMION protocol is supported as well. A more detailed description of these two protocols can be found in the. 5.1 General information Safety information The change from pressure measurement using the Pirani principle to pressure measurement using the Bayard-Alpert measuring principle and back is made by the control electronics. Nevertheless, it is important to point out that the Bayard-Alpert gauge may be irreparably damaged in case of inrush airing. Minimize the contamination of the sensor (e.g. via a baffle, see accessories), since contaminations may drastically reduce the reproducibility of the sensor and may lead to failures in extreme case. Slight contaminations may be cleaned by repeated outgassing cycles in a clean vacuum environment (p < 1 x 10-5 mbar). Make sure that strong vibrations of the sensor are avoided, since those vibrations may irreparably damage the Pirani gauge. 5.2 Adjustment As explained in the last section, the BARION atm automatically switches between its two measuring principles. In doing so, it is switched from Pirani to hot cathode at a pressure of 1 x 10-2 mbar, and from hot cathode to Pirani at a pressure of 1 x 10-1 mbar. In order to ensure good coordination of both measuring principles, an adjustment is required. Regarding such an adjustment, the upper and the lower measuring limit of the Pirani measuring gauge are specified by the user. At atmospheric pressure (e. g. when the chamber is open), the sensor is informed that there is a pressure of 1000 mbar. At a pressure p < 1 x 10-3 mbar, the sensor receives the confirmation that the lower measuring range has been reached. 5.3 Setpoints BARION atm is equipped with two independent setpoint relais. These can be programmed via RS232 interface. The electrical contacting is possible via SUB-D connector (see chapter 4.1) 07 / 2016 BARION atm Manual 11

12 5 Operation 5. Control by the way of +24 V Steuersignalen Elementary control signals can be transmitted to BARION atm by wiring of the inputs Control 1 (RxD) and Control 2 (TxD) with +24 V. Control 1 (0 V) Control 2 (0 V) Normal operation Control 1 (+24 V) Control 2 (0 V) Start Degas Control 1 (0 V) Control 2 (+24 V) Pirani only operation Hot cathode gauge off as long as +24 V active Control 1 (+24 V) Control 2 (+24 V) Adjustment Pirani gauge* * atmosphere or vacuum adjustment depends from the displayed pressure at the time of this adjustment: >10 mbar atmosphere adjustment < 1 mbar vacuum adjustment. 12 BARION atm Manual 07 / 2016

13 6 Maintenance 6.1 Cleaning and care The BARION atm is maintenance-free. For cleaning the housing, the supply voltage must be switched off by unplugging the plug-in power supply. The housing can be cleaned using a soft, slightly damp cloth. Using aggressive cleaning agents should be avoided since this may attack the surfaces. 6.2 Firmware update Possible firmware updates may quickly be installed on the BARION atm by the customer. The current firmware versions and a programme for installing the firmware can be downloaded from our website at In case of special requests, such as older or special firmware versions, please contact your customer adviser or inform us. Regarding the update procedure, proceed as follows: 1. Connect the BARION atm via a RS232 cable to your PC. 2. Connect the power supply to the BARION atm. 3. Open the programme VACOM Firmware updater (File name: firmwarewpf.exe) 4. Select the language English and click Next twice. 5. Select the COM port to which the BARION atm is connected. 6. Do not change the baud rate, the correct value kb / s is preset. If an error message is displayed here, check whether the communication with the BARION atm is ensured, i. e. whether it is correctly connected, supplied with power and whether the correct COM port is selected. 7. After clicking Next again, search in the File field for the firmware which you want to install on the BARION atm. 8. Click on Update in the next window. Here, it is displayed which firmware is currently installed on the device and which firmware shall be loaded to the device. 07 / 2016 BARION atm Manual 13

14 7 Troubleshooting Problem Cause Measure There is no change from the Pirani to the hot cathode mode, even though the pressure would allow it While measuring with the hot cathode, a pressure too low or a heavily varying pressure is displayed Adjustment from the Pirani incorrect Sensor contaminated Sensitivity values incorrectly set Repeat adjustment Perform degas Reset sensor again to factory-set sensitivity values In case of doubts or other occurring problems, please contact our support at 14 BARION atm Manual 07 / 2016

15 8 Return / disposal Contamination of the product: If the BARION atm was used in atmospheres with substances hazardous to health or the environment, these substances must be indicated at the disposal company. In case of returning the sensor to the VACOM Vakuum Komponenten & Messtechnik GmbH, a legally binding declaration on the contamination of the product must be completed and signed by a competent person. The Declaration of Contamination can be downloaded from Without an enclosed Declaration of Contamination, a return delivery is not accepted and sent back. 07 / 2016 BARION atm Manual 15

16 A.1 Technical data The BARION atm is a wide-range vacuum meter consisting of a hot cathode and a heat loss vacuum meter according to the Pirani principle. With this device, a failure-free process control from atmosphere up to the UHV regime is possible. By a high variety of interfaces, an easy system integration is guaranteed. range Accuracy Reproducibility Max. bake-out temperature 5 x 10-8 to 1 x Pa 5 x to 1000 mbar 4 x to 750 torr ± 20 % of the measured value ± 5 % of the measured value CF version: 220 C at the flange KF version: 150 C at the flange Max. operating temperature 50 C Filaments Setpoints Maximum power Dimensions (H x W x D) Possible vacuum connections Available interfaces 2 Y 2 O 3 coated filaments 2 (1 x floating, 1 x grounded) 30 V DC / 0,5 A, max 100 V to ground! 15 W 122 x 73 x 66 mm DN40CF / DN25KF RS232, analogue (0 to 10 V, 0 to 20 ma), Profibus optional, other interfaces upon request 16 BARION atm Manual 07 / 2016

17 A.2 Accessories The following accessories are available for the BARION atm: Article number Description BARION-ATM-PS-EU Power supply unit* ATLPC3 RS232 cable, length 3 m* BAA3 Adapter cable for VMG, length 3 m* KF25LBAFFLE3-SVCR-304 Lamella baffle DN25KF CF40LBAFFLE3-SVCR-304 Lamella baffle DN40CF * Other versions on request A.3 Communication with the BARION atm The BARION atm has the following communication interfaces: Via an RS232 interface, communication is possible via both the VACOM protocol and the ATMION protocol. At an analogue interface, both a current proportional to the pressure and a voltage proportional to the pressure can be output. Optionally, there are possibilities of a PROFIBUS or other fieldbus communication. Please refer to the corresponding manuals for information on the VACOM protocol and the fieldbus systems; here, details of the ATMION protocol are presented. A.3.1 ATMION protocol As an alternative to the VACOM protocol, the ATMION protocol can also be used for interacting with the BARION atm. (VACOM Protocol see chapter 5.4) 07 / 2016 BARION atm Manual 17

18 A.3.2 Port settings The following settings are provided for the RS232 communication: Baud rate Data bits 8 Stop bit 1 Parity Protocol None None A.3.3 Command set The general format of the commands is as follows: <Command><Command parameter><cr> Command RV RS RP RT SD SC**** SP**** **** SX1 SX0 Function Reading the current pressure value. Reading the status bit (see below for more details). Reading the setpoint value for SP On and SP Off. Output value in hex. Reading the operating time of the filaments. Degas (2 min) Set control bit. Input values in hex. Set setpoint values for SP On and SP Off. Input values in hex. Start automatic transmission of pressure and service values every 500 ms. Stop automatic transmission of pressure and service values. 18 BARION atm Manual 07 / 2016

19 A.3.4 Pressure output via RV As shown in the table, the current pressure value can be read out via RV<CR>. The response string has the following form: <Mode>_<Pressure> The pressure has thereby the form 0.00E+/-00. The different modes are explained in the following table: Mode Description P Pirani measuring mode I1 Ionisation measuring mode with filament 1 I2 Ionisation measuring mode with filament 2 D Degas E Error A.3.5 Calculation of the input values for specifying the setpoint The pressures, at which a setpoint is switched on or switched off, are saved in the hex format. The conversion is as follows: Input value = *log (p) Here, the pressure value p is given in mbar. 07 / 2016 BARION atm Manual 19

20 A.3.6 Meaning of the status bits Status bits can be read out via the command RS<CR>. The response is a four-digit hexadecimal number and stands for 16 bits. The individual bits stand for various status information. The 16 bits are divided into four sections, which can, in each case, be described by a hexadecimal number. The following table explains the meanings of the individual status bits and how to decode a sample code (in this case 001D). Bit Meaning Hex Bit 0 Pressure-dependent switching of gauge active D 1 1 Pirani active, measured value is output 0 2 Ionisation gauge active, measured value is output Filament is automatically selected Filament 1 active Filament 2 active 0 6 Degas active 0 7 Small emission current range active 0 8 Setpoint is controlled externally State at the setpoint output 0 10 Setpoint function is active 0 11 External inputs for system control are activated 0 12 Error bit is reset Adjustment at vacuum is activated 0 14 Adjustment at atmospheric pressure is activated 0 15 Live signal 0 A response to the command RS<CR> is read from right to left. As shown above, the code 001D means that the measuring mode is changed pressure-dependently, the automatic filament selection and the ionisation gauge are activated and the filament 1 is running. 20 BARION atm Manual 07 / 2016

21 A.3.7 Meaning of the control bits As described further above, the control bits can be set via the command SC<Value><CR>. As in the case of the status bits, the 16 individual bits stand for certain detailed information. In the following table, they are described and illustrated with an example, the command SC 0049<CR>. Bit Meaning Hex Bit 0 Specification of the pressure-dependent switching Measurement only in the Pirani mode. 0 2 Measurement only in the ionisation mode. 0 3 Setting of the automatic filament selection. 1 4 Use of filament Use of filament Initiation of degas. 1 7 Set small emission current. 0 8 Switch setpoint independently of the pressure value If bit 8 is set: Setpoint switch On / Off Switch setpoint depending on pressure Release external inputs for analogue control Error bit is reset Adjustment at vacuum is activated 0 14 Adjustment at atmospheric pressure is activated 0 15 N. a. 0 It is obvious that the command SC 0049<CR> starts a degas process with automatically selected filaments and automatically selected measuring mode. A.4 Legally binding Declaration of Contamination The legally binding Declaration of Contamination is provided for download at 07 / 2016 BARION atm Manual 21

22 A.5 VACOM Protocol (quick start) The VACOM Protocol enables a simple, flexible and reliable interface communication with VA- COM devices. It s possible to use this next to other existing protocols who are continued to support for reasons of compatibility. A.5.1 Setups The VACOM device is always the client. It will only reply, when it is asked by the master (as a rule the PC). The connection between client and master takes place by means of serial interfaces (RS232, RS422 oder RS485). Connection settings: Standard data transmission rate: bit /s because of compatibility to older devices the data transmission rate of 9.600, , und bit/s are supported note: there are no automated detection Transmission format: 8N1 (8 data bit, no parity 1, and one stop bit) Kinds of connections: a) 1:1 connection: 1 master, 1 client (RS232) b) Bus system 2 : 1 master, a few clients (RS422) c) Bus system: a few master, a few clients (RS485) Data transmission: Transmission of data packets with a fixed size of 24 byte and a fixed structur Content: target and source address, tax information (for leading the data flow), transferred parameters, checksum displayed information of the data packet at the hexadecimal system 1 parity = is used to identify incorrect transferred information (here: effective securing of the data transmission via cecksum) 2 for entering commands of bus systems see extended VACOM Protocol 22 BARION atm Manual 07 / 2016

23 A.5.2 Entering commands (for 1:1 connections 1 master & 1 client) Important and often used functions of the VACOM devices can be outputted directly as a command via serial interface. Example A EF Fixed value Command and subcommand actual commands and functions transferred parameters only at set commands and. by specifying of the measure. ment channel, field number.. or of the set points Checksum n fixed value for commands where no parameters are passed n for commands where parameters are passed, you can find a special program on our website for the calculation of the checksum 07 / 2016 BARION atm Manual 23

24 A Valide commands for all devices (for 1:1 connections 1 master & 1 client)) A EF Fixed value request serial number = command no transferred parameters Checksum n fixed value for commands where no parameters are transferred Fixed value Command and subcommand transferred parameters Checksum Value Meaning / answer of the client Transfer Parameter Value request name Answer: name of the device (zero terminated 3 string 4 ) EF A request software version Answer: version number of the software (zero terminated string) without a valid firmware, an empty string will be returned F request serial number Answer: serial number, if available (zero terminated string) --- C8 8F 3 zero- terminated = the finish stopped with 0 4 String = sequence of characters (letters, numbers, special and control characters) in ASCII code 24 BARION atm Manual 07 / 2016

25 A Commands for the device class of pressure gauges (for 1:1 connections 1 master & 1 client) A D Fixed value request actual value string (mbar) = command channel 5: = transferred parameters Checksum n fixed value for commands where no parameters are passed Fixed value Command and subcommand transferred parameters Checksum Value Meaning / answer of the client Transfer Parameter Value request actual value string (mbar) Answer: actual pressure value in mbar (zero terminated string) channel (8 bit value) ** channel No.: 1 FF 8C channel No.: 2 BF 7D A request setpoint thresholds (mbar) Answer: lower and upper switching threshold in mbar (float 5 values) + set point number Number of the setpoint (8 bit value) ** Set point No.: Set point No.: set setpoint thresholds (mbar) Answer: actuating value lower and upper switching threshold in mbar (float values), number of the setpoint (8 bit value) ** ** There is a special program on our website for the calculation of the checksum for other parameters. 5 float = floating point number; consists of signs, mantissa, base and exponent in the form X=s*m*be Typ single (32 bit); Little Endian (DCBA) according to ANSI / IEEE Std / 2016 BARION atm Manual 25

26 A Commands for the device class of the ion getter pumps (IGP) (for 1:1 connections 1 master & 1 client) A AB 7B Fixed value get voltage (V) = command channel no. 18: = transferred parameters Checksum n fixed value for commands, where no parameters are transferred Fixed value Command and subcommand transferred parameters Checksum ** Value Meaning / answer of the client Transfer Parameter Value 20 0C request actual current value string (A) Answer actual current in A (zero terminated string) channel (8 bit value) channel No.: A channel No.: 2 77 BB A request actual pressure value string (mbar) Answer: actual pressure value in mbar (zero terminated string) get voltage (V) Answer: aktual voltage in V (float value), measuring channel number (8 bit value) channel (8 bit value) channel (8 bit value) channel No.: 1 FF 8C channel No.: 2 BF 7D channel No.: 1 E6 46 channel No.: 2 A6 B get nominal voltage (V) Answer: aktual set voltage in V (float value), measuring channel number (8 bit value) channel (8 bit value) channel No.: channel No.: set nominal voltage (V) Answer: --- (note: a value of 0.0 effected the return to the automatic mode) new set voltage in V (float value), measuring channel number (8 bit value) ** 26 BARION atm Manual 07 / 2016

27 Fixed value Command and subcommand transferred parameters Checksum ** request setpoint threshold (A) Antwort: lower and upper switching threshold in A (float values), number of the setpoint (8 bit value) Number of the setpoint (8 bit value) ** Set point No.: Set point No.: 2 51 C1 A request setpoint threshold (mbar) Antwort: lower and upper switching threshold in mbar (float values), number of the setpoint (8 bit value) Number of the setpoint (8 bit value) ** Set point No.: 1 D4 33 Set point No.: 2 94 C2 22 0C set setpoint threshold (A) Answer: actuating value lower and upper switching threshold in A (float values), number of the setpoint (8 bit value) ** set setpoint threshold (mbar) Answer: actuating value lower and upper switching threshold in mbar (float values), number of the setpoint (8 bit value) ** ** There is a special program on our website for the calculation of the checksum for other parameters. 07 / 2016 BARION atm Manual 27

28 A Special commands for GAPAS (for 1:1 connections 1 master & 1 client) A E E 61 Fixed value request 60-min-history (mbar) = command field number 14: = transferred parameters Checksum n fixed value for commands, where no parameters are transferred Fixed value Command and subcommand transferred parameters Checksum Value Meaning / answer of the client Transfer Parameter Value A request 60-min-history (mbar) Answer: 8 pressure value in mbar in logarithmic scale (16 bit value) field number [0 14] ** field number: 1 6B 95 field number: 2 2B request 24-h-history (mbar) Answer: 8 pressure values in mbar in logarithmic scale (16 bit value) field number [0 14] ** channel No.: 1 E1 92 channel No.: 2 A1 63 ** There is a special program on our website for the calculation of the checksum for other parameters. 28 BARION atm Manual 07 / 2016

29 A Special commands for Barion atm (for 1:1 connections 1 master & 1 client) A C 3B Fixed value request 60-min-history (mbar) = command field number 14: = transferred parameters Checksum n fixed value for commands, where no parameters are transferred Fixed value Command and subcommand transferred parameters Checksum Value Meaning / answer of the client Transfer Parameter Value request serial number (head) Answer: serial number (zero terminated string) (serial number of the sensor head is safed on whose EEPROM) --- ** field number: 1 6B 95 field number: 2 2B 64 A get output mode Answer: output mode (8 bit value) 0 voltage output 1 power output (0 20 ma) 2 power output (4 20 ma) --- ** channel No.: 1 E1 92 channel No.: 2 A set output mode Answer: actuating value Output mode (8 bit value) 0 voltage output 1 power output (0 20 ma) 2 power output (4 20 ma) ** Output mode: Output mode: 1 B0 02 Output mode: 2 F0 F3 07 / 2016 BARION atm Manual 29

30 Fixed value Command and subcommand transferred parameters Checksum A F0 reset to factory values Answer: --- note: values like lifetimes etc. will not be reset F4 Pirani gauge adjust atmosphere value Answer: --- set the current value of the Pirani gauge as the value for atmosphere --- 7C 3B adjust vacuum value Answer: --- set the current value of the Pirani gauge as the value for vacuum --- 2D AB A get cold resistance Answer: resistance of the Pirani gauge at 0 C in Ohm (float value) set cold resistance Answer: actuating value (float value) Resistance of the Pirani gauge at 0 C in Ohm 71 FE ** 41 F0 self calibration Answer: --- note: starts a measurement of the cold resistance of the Pirani gauge, whereby it is blocked for 1 minute --- D0 9E get lifetime Answer: the entire operating time of the Pirani gauge in seconds (float value) F1 30 BARION atm Manual 07 / 2016

31 Fixed value Command and subcommand transferred parameters Checksum hot cathode start degas Answer: --- note: start of a degas process, if the hot cathode is still running and the maximum pressure for starting the degas is falling below --- DD EF get filament selection Answer: information which filament is choosen (8 bit value) (8-Bit-Wert) 0 filament off 1 only filament 1 2 only filament automatical selection BA A set filament selection Answer: actuating value information which filament is choosen (vorzeichenloser 8-Bit-Wert) 0 filament off 1 only filament 1 2 only filament automatical selection anderer Wert Filament aus ** Filament information: 0 D0 2A Filament information: 1 11 BA Filament information: B Filament information: 3 90 DB get sensitivity filament 1 Answer: sensitivity of filament 1 in 1 / mbar (float value) B set sensitivity filament 1 Answer: actuating value (float value) Sensitivity of filament 1 in 1 / mbar (float value) C set sensitivity filament 2 Answer: actuating value (float value) ** 07 / 2016 BARION atm Manual 31

32 Fixed value Command and subcommand transferred parameters Checksum set sensitivity filament 2 Answer: actuating value (float value) Sensitivity of filament 2 in 1 / mbar (float value) ** get factory set sensitivity filament 1 Answer: adjusted sensitivity of filament 1 in 1 / mbar (float value) A get factory set sensitivity filament 2 Answer: adjusted sensitivity of filament 2 in 2 / mbar (float value) E get lifetime filament 1 Answer: operating time of filament 1 in seconds (not exactly!) get lifetime filament 2 Answer: operating time of filament 2 in seconds (not exactly!) --- C9 E0 ** For calculating checksum for other parameters you can find a special program on our website. 32 BARION atm Manual 07 / 2016

33 07 / 2016 BARION atm Manual 33

34 34 BARION atm Manual 07 / 2016

35 07 / 2016 BARION atm Manual 35

36 Vakuum Messtechnik VACOM Vakuum Komponenten & Messtechnik GmbH Gabelsbergerstraße Jena Germany Tel Fax

VACOM ATMION. Active Wide Range Vacuum Gauge Standard and Compact Version. Instruction Manual 09/2004.

VACOM ATMION. Active Wide Range Vacuum Gauge Standard and Compact Version. Instruction Manual 09/2004. VACOM Active Wide Range Vacuum Gauge Standard and Compact Version Instruction Manual 09/2004 www.vacom-vacuum.com 0. Table of Contents 0. Table of Contents 1 0.1 List of Figures 3 0.2 List of Tables 3

More information

BNI USB A501. USB IO-Link Master User's Guide. english

BNI USB A501. USB IO-Link Master User's Guide. english User's Guide english 1 2 4 Notes to the user 1.1 About this guide 1.2 Structure of the guide 1. Typographical conventions 1.4 Symbols 1.5 Abbreviations Safety 4 2.1 Intended use 4 2.2 General safety notes

More information

CMC III Universal Sensor

CMC III Universal Sensor CMC III Universal Sensor DK 7030.190 Assembly and operating instructions Foreword Foreword Dear Customer, Thank you for choosing our CMC III universal sensor (referred to hereafter as "universal sensor")!

More information

Serial PROFIBUS Interface

Serial PROFIBUS Interface Installation Manual Serial PROFIBUS Interface Version: EN-062016-2.3 Copyright 2016 Softing Industrial Automation GmbH Disclaimer of liability The information contained in these instructions corresponds

More information

Polymer Electric. Operating Instructions. Control Unit SG-EFS 1X4 ZK2/1 8k2. Version 3

Polymer Electric. Operating Instructions. Control Unit SG-EFS 1X4 ZK2/1 8k2. Version 3 Operating Instructions Control Unit SG-EFS 1X4 ZK2/1 8k2 Version 3 1003100 SG-EFS 104 ZK2/1 8k2 24 V=/~ 7500354 SG-EFS 134 ZK2/1 8k2 230 V~ Original instructions GmbH & Co. KG Polymer Electric Örlinger

More information

Control unit SG-EFS 104/2W. EN Operating instructions. Innovative by tradition. Version SG-EFS 104/2W 24 V=/~

Control unit SG-EFS 104/2W. EN Operating instructions. Innovative by tradition. Version SG-EFS 104/2W 24 V=/~ Innovative by tradition. Control unit SG-EFS 104/2W EN Operating instructions Version 0.9 1005196 SG-EFS 104/2W 24 V=/~ Original instructions Mayser GmbH & Co. KG Örlinger Straße 1 3 89073 Ulm GERMANY

More information

CMC III Temperature/Humidity Sensor

CMC III Temperature/Humidity Sensor CMC III Temperature/Humidity Sensor DK 7030.111 Assembly and operating instructions Foreword Foreword Dear Customer, Thank you for choosing our CMC III temperature/humidity sensor (referred to hereafter

More information

Instruction Manual IF2004/USB. 4-Channel RS422/USB Converter

Instruction Manual IF2004/USB. 4-Channel RS422/USB Converter Instruction Manual 4-Channel RS422/USB Converter The following sensors/systems can be connected to the 4-Channel RS422/USB Converter: Sensors of the ILD 1302 / 1402 / 1700 / 2200 / 2300 series Sensors

More information

Operating Instructions

Operating Instructions TPS S1 AC in DC out Translation of the original instructions TPS 110-400 Mains pack Operating Instructions PT 0199 BEN/C (1010) EN Table of contents Table of contents 1 About this manual...............................................

More information

Operating Manual. English. Digital-Analog Converter DACON8-UMB.

Operating Manual. English. Digital-Analog Converter DACON8-UMB. English Digital-Analog Converter www.lufft.de G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany. We reserve the right to amend technical specifications at any time. Contents 1 Please Read Before

More information

Operating Instructions SECUTEST SI /12.10

Operating Instructions SECUTEST SI /12.10 Operating Instructions SECUTEST SI+ 3-349-613-15 1/12.10 6 5 4 3 2 1 MENU SECUTEST SI+ 7 6 8 without Function 9 10 11 12 13 14 Standard Equipment 1 Input and memory module SECUTEST SI+, 1 USB connector

More information

PKP Prozessmesstechnik GmbH. Borsigstrasse 24. D Wiesbaden-Nordenstadt. Tel: / Fax: / Operating manual PSA06

PKP Prozessmesstechnik GmbH. Borsigstrasse 24. D Wiesbaden-Nordenstadt. Tel: / Fax: / Operating manual PSA06 PKP Prozessmesstechnik GmbH Borsigstrasse 24 D-65205 Wiesbaden-Nordenstadt Tel: 06122 / 7055-0 Fax: 06122 / 7055 50 Operating manual PSA06 Electronical pressure switch Content Page 19-34 1. Foreword 19

More information

BNI IOL Z013 BNI IOL-302-S01-Z013. User s Guide

BNI IOL Z013 BNI IOL-302-S01-Z013. User s Guide BNI IOL302000Z013 BNI IOL302S01Z013 User s Guide Balluff Network Interface / IOLink BNI IOL302xxxZ013 1 Notes for the user 1.1 About this guide 2 1.2 Structure of the guide 2 1.3 Typographical conventions

More information

English. Operating manual. Universal transmitter UT125. Save for later reference. Companies / brands of GHM

English. Operating manual. Universal transmitter UT125.  Save for later reference. Companies / brands of GHM English Operating manual Universal transmitter UT125 Companies / brands of GHM www.ghm-messtechnik.de Save for later reference. Table of contents page 1. Intended use (areas of application)... 3 1.1 Safety

More information

BTL6-A_10-M -A1-S115. Data Sheet. english

BTL6-A_10-M -A1-S115. Data Sheet. english BT6-A_10-M -A1-S11 english Data Sheet Balluff GmbH Schurwaldstrasse 9 76 Neuhausen a.d.f. Germany Phone +49 (0) 71 8/1-0 Fax +49 (0) 71 8/0 10 Servicehotline +49 (0) 71 8/1-70 E-Mail: balluff@balluff.de

More information

Communication Protocol DeviceNet Interface for Bayard-Alpert / Pirani Gauge and High Pressure / Pirani Gauge BPG400-SD HPG400-SD tira03e1-b (0310) 1

Communication Protocol DeviceNet Interface for Bayard-Alpert / Pirani Gauge and High Pressure / Pirani Gauge BPG400-SD HPG400-SD tira03e1-b (0310) 1 Communication Protocol DeviceNet Interface for Bayard-Alpert / Pirani Gauge and High Pressure / Pirani Gauge BPG400-SD HPG400-SD tira03e1-b (0310) 1 Intended Use of this Document This Communication protocol

More information

PTB 01 ATEX Example / Beispiel / Exemple. Type Operating Instructions

PTB 01 ATEX Example / Beispiel / Exemple. Type Operating Instructions Device with II 2G EX i approval Geräte mit II 2G EX i Zulassung Appareils avec mode de protection II 2G EX i Example / Beispiel / Exemple Type 6106 Operating Instructions Bedienungsanleitung Manuel d utilisation

More information

BNI IOL-104-S01-Z012-C02

BNI IOL-104-S01-Z012-C02 BNI IOL104S01Z012C01 BNI IOL104S01Z012C02 BNI IOL302S01Z013C01 User s Guide Balluff Network Interface / IOLink 1 Notes for the user 1.1 About this guide 2 1.2 Structure of the guide 2 1.3 Typographical

More information

Hygro-/Thermometer. Operating Manual GFTH 95

Hygro-/Thermometer. Operating Manual GFTH 95 H53.0.X1.6C-07 Hygro-/Thermometer Operating Manual GFTH 95 WEEE-Reg.-No. DE93889386 GHM Messtechnik GmbH Standort Greisinger Hans-Sachs-Str. 26 D-93128 Regenstauf +49 (0) 9402 / 9383-0 +49 (0) 9402 / 9383-33

More information

DeviceNet Interface for Bayard-Alpert Pirani Gauge

DeviceNet Interface for Bayard-Alpert Pirani Gauge Communication Protocol DeviceNet Interface for Bayard-Alpert Pirani Gauge BPG402-SD tira46e1 (2004-11) 1 Intended Use of this Document This Communication protocol contains instructions for operating the

More information

Operating instructions Memory plug E /02 11/2011

Operating instructions Memory plug E /02 11/2011 Operating instructions Memory plug E30398 UK 704930/02 11/2011 Contents 1 Preliminary note...3 1.1 Symbols used...3 1.2 Terms used...3 2 Safety instructions...4 3 Factory setting...4 4 Functions and features...5

More information

Installation manual plugs and connectors with screw connection (16/32 A)

Installation manual plugs and connectors with screw connection (16/32 A) EN Installation manual plugs and connectors with screw connection (16/32 60003213 Issue 04.2016 2016-04-01 Table of contents 1 About this manual 3 1.1 Structure of the warnings 3 1.2 Symbols used 4 1.3

More information

D Issue A. Instruction Manual. Active Strain Gauge

D Issue A. Instruction Manual. Active Strain Gauge Instruction Manual D357-35-880 Issue A Active Strain Gauge Description ASG2-1000-1/8 NPT ASG2-1000-NW16 ASG2-2000-1/8 NPT ASG2-2000-NW16 Item Number D357-35-000 D357-36-000 D357-37-000 D357-38-000 Declaration

More information

HARDENED ROOM SENSOR USER MANUAL SAD120 CPO55 E 1

HARDENED ROOM SENSOR USER MANUAL SAD120 CPO55 E 1 HARDENED ROOM SENSOR USER MANUAL SAD120 CPO55 LOREME 12, rue des Potiers d'etain Actipole BORNY - B.P. 35014-57071 METZ CEDEX 3 Phone 03.87.76.32.51 Contact : Commercial@Loreme.fr - Technique@Loreme.fr

More information

Installation- and Operating instructions for CU CFast card adapter with USB connector. Version: 1.1 Date:

Installation- and Operating instructions for CU CFast card adapter with USB connector. Version: 1.1 Date: Installation- and Operating instructions for CU8871-0000 CFast card adapter with USB connector Version: 1.1 Date: 2013-12-06 Table of contents Table of contents 1 Foreword 3 1.1 Notes on the Documentation

More information

DN-DP PROFIBUS-DP / DeviceNet-Gateway

DN-DP PROFIBUS-DP / DeviceNet-Gateway PROFIBUS-DP / DeviceNet-Gateway Hardware Manual to Product C.2930.02 Hardware Manual Doc.-No.: C.2930.21 / Rev. 1.2 Page 1 of 17 esd electronic system design gmbh Vahrenwalder Str. 207 30165 Hannover Germany

More information

mark150s mark150/485s DDC controllers Summary

mark150s mark150/485s DDC controllers Summary mark150s mark150/485s DDC controllers Summary DDC (Direct digital control) controller mark150s and mark150/485s are free programmable process stations with ARM Cortex M4 processor and OS FreeRTOS. They

More information

B63/ NS MS. EtherNet/IP LINK

B63/ NS MS. EtherNet/IP LINK 3 609 929 B63/ IMenip 2008-09 NS MS EtherNet/IP LINK 3 609 929 B63/2008-09 IMenip Bosch Rexroth AG 15/76 Table of Contents About this document................. 16 General safety instructions............

More information

Device technology. Supply Bus voltage V DC. Current consumption via bus. Accuracy in the range 300 1,000 ppm 1,000 2,000 ppm 2,000 5,000 ppm

Device technology. Supply Bus voltage V DC. Current consumption via bus. Accuracy in the range 300 1,000 ppm 1,000 2,000 ppm 2,000 5,000 ppm 2 2.1 Air Quality Sensor LGS/A 1.1 The ABB i-bus KNX Air Quality Sensor 1.1 is a combined sensor for CO 2, temperature and humidity measurement (relative humidity). Three independent thresholds can be

More information

SegoSerial Industrial Grade Converter Isolated Dual RS232 - USB. Installation and operation. English Rev. 1.2 Status June I9

SegoSerial Industrial Grade Converter Isolated Dual RS232 - USB. Installation and operation.  English Rev. 1.2 Status June I9 SegoSerial Industrial Grade Converter Isolated Dual RS232 - USB Installation and operation www.segosoft.info English Rev. 1.2 Status June 2013 1I9 Contents Introduction... 3 Product features... 3 Description

More information

BNI IOL Z012. User s Guide

BNI IOL Z012. User s Guide BNI IOL205000Z012 User s Guide Balluff Network Interface / BNI IOL205000Z012 1 Notes for the user 1.1 About this guide 2 1.2 Structure of the guide 2 1.3 Typographical conventions 2 1.3.1 Enumerations

More information

Demonstration Case BENNING DB 1

Demonstration Case BENNING DB 1 Operating manual Demonstration Case BENNING DB 1 part no. 044132 Table of contents 1 Introduction...3 2 Safety instructions...4 3 Applicable regulations...5 4 Device description...5 4.1 Measuring / testing...

More information

Englisch. Operating Manual. Operating Software GHMware Retain for further references. Unternehmen / Marken der GHM

Englisch. Operating Manual. Operating Software GHMware Retain for further references. Unternehmen / Marken der GHM Englisch Operating Manual Operating Software GHMware 2.02 Unternehmen / Marken der GHM Programming Adapter EYY120 www.ghm-messtechnik.de Retain for further references. Table of Contents Page 1 Intended

More information

Cube LAN Gateway. Operating manual BC-LGW-O-TW

Cube LAN Gateway. Operating manual BC-LGW-O-TW Cube LAN Gateway Operating manual BC-LGW-O-TW Package contents Package contents Quantity Item 1x MAX! Cube LAN Gateway 1x 1x 1x 1x 1x 3x Plug-in USB power supply USB cable Network cable Mounting accessories

More information

Instruction Manual IF2004/USB. 4-Channel RS422/USB Converter

Instruction Manual IF2004/USB. 4-Channel RS422/USB Converter Instruction Manual 4-Channel RS422/USB Converter The following sensors/systems can be connected to the 4-Channel RS422/USB Converter: Sensors of the ILD 1302 / 1402 / 1420 / 1700 / 2200 / 2300 series Sensors

More information

Technical data. Safety notes. Product features

Technical data. Safety notes. Product features Technical data sheet BKN230-MOD 11-00002.F Communication and power supply unit for motorised fire dampers Communication via RTU (RS-48) AC 230 V supply via Euro plug Power is supplied to the actuators

More information

AD-8923-BCD. Remote Controller (BCD) INSTRUCTION MANUAL 1WMPD

AD-8923-BCD. Remote Controller (BCD) INSTRUCTION MANUAL 1WMPD AD-8923-BCD Remote Controller (BCD) INSTRUCTION MANUAL 1WMPD4002137 2010 A&D Company, Limited. All rights reserved. No part of this publication may be reproduced, transmitted, transcribed, or translated

More information

Installation- and Operating instructions for CU Ethernet Controller with USB Input. Version: 1.4 Date:

Installation- and Operating instructions for CU Ethernet Controller with USB Input. Version: 1.4 Date: Installation- and Operating instructions for CU8880-0010 Ethernet Controller with USB Input Version: 1.4 Date: 2018-04-12 Table of contents Table of contents 1. 2. 3. 4. 5. General instructions 2 Notes

More information

Polymer Electric. Operating Instructions. Control Unit SG-RST 153. Version 0.3

Polymer Electric. Operating Instructions. Control Unit SG-RST 153. Version 0.3 Operating Instructions Control Unit SGRST 153 Version 0.3 1004931 SGRST 153 Original instructions GmbH & Co. KG Örlinger Straße 1 3 89073 Ulm GERMANY Tel.: +49 731 20610 Fax: +49 731 2061222 EMail: info.ulm@mayser.com

More information

EPS Power Supply

EPS Power Supply EPS - 600 Power Supply Installation and Operation Manual Version 1.0 *This instrument is intended for laboratory use only Index A. Important Notice ----------------------------------------------------------------

More information

SolConeX extra-low voltage flange socket

SolConeX extra-low voltage flange socket SolConeX extra-low voltage flange socket Operating instructions Additional languages www.stahl-ex.com Contents 1 General Information...3 1.1 Manufacturer...3 1.2 Information regarding the operating instructions...3

More information

PSG550, PSG552, PSG554

PSG550, PSG552, PSG554 PSG550, PSG55, PSG554 Pirani Standard Gauge The INFICON Pirani Standard Gauge (PSG55x) employs like his brothers PCG55x and PSG50x the most advanced digital Pirani technology available. The rugged sensor

More information

I/O module, universal, digital, S0 inputs, modu533

I/O module, universal, digital, S0 inputs, modu533 Product data sheet 5.1 92.046 EY-IO 533: I/O module, universal, digital, S0 inputs, modu533 How energy efficiency is improved SAUTER EY-modulo 5 technology: modular, fast and universal Features Part of

More information

L Series Humidity/-temperature sensors for use in heating, ventilation and air conditioning Technical data Humidity

L Series Humidity/-temperature sensors for use in heating, ventilation and air conditioning Technical data Humidity Galltec Mess- und Regeltechnik GmbH MELA Sensortechnik GmbH Boschstr. 4 Raasdorfer Str. 18 71145 Bondorf. Germany 07987 Mohlsdorf-Teichwolframsdorf. Germany Tel. +49 (0)7457-9453-0 Tel. +49(0)3661-62704-0

More information

Card Enrollment Station. User Manual UD05870B

Card Enrollment Station. User Manual UD05870B Card Enrollment Station User Manual UD05870B User Manual 2017 Hangzhou Hikvision Digital Technology Co., Ltd. This manual is applied for D8E series card enrollment station. It includes instructions on

More information

Original operating instructions. Fail-safe SmartPLC with Profinet slave interface AC402S /00 06/2016

Original operating instructions. Fail-safe SmartPLC with Profinet slave interface AC402S /00 06/2016 Original operating instructions Fail-safe SmartPLC with Profinet slave interface AC402S UK 80237419/00 06/2016 Contents 1 Preliminary note...4 1.1 Notes on this document...4 1.2 Symbols used...4 2 Safety

More information

AX522 Analog Input/Output Module

AX522 Analog Input/Output Module Ordering Data DATA SHEET AX522 Analog Input/Output Module 1 Ordering Data Part No. Description Product Life Cycle Phase *) 1SAP 250 000 R0001 1SAP 450 000 R0001 AX522, analog input/output module, 8 AI

More information

1 IF-810 or IF-811 Terminal (Slave) 2 Intended Use. 3 Assembly and Installation _V IF-810/IF-811

1 IF-810 or IF-811 Terminal (Slave) 2 Intended Use. 3 Assembly and Installation _V IF-810/IF-811 95-10326_V2016-10-20 IF-810/IF-811 1 IF-810 or IF-811 Terminal (Slave) Thank you for choosing an Interflex system. With an IF-810 or IF-811 terminal (slave), you have purchased a reliable device for capturing

More information

UDC 1000 and UDC 1500 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS

UDC 1000 and UDC 1500 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS UDC 1000 and UDC 1500 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS EN0I-6041 12/99 PRODUCT SPECIFICATION SHEET OVERVIEW The UDC 1000 and UDC 1500 are microprocessor-based 1/16 DIN and 1/8 DIN controllers

More information

Hardware Manual RM CANview Gateway

Hardware Manual RM CANview Gateway Hardware Manual RM CANview Gateway 2008 RM Michaelides Software & Elektronik GmbH Donaustraße 14 D-36043 Fulda Germany cvgateway-hw-e.doc Table Of Contents 1 Legal Regulations... 3 2 About the CANview

More information

2-CHANNEL MODULE OF ANALOG INPUTS SM1 TYPE

2-CHANNEL MODULE OF ANALOG INPUTS SM1 TYPE 2-CHANNEL MODULE OF ANALOG INPUTS SM1 TYPE USER S MANUAL 1 2 CONTENTS 1. APPLICATION...5 2. MODULE SET...6 3. BASIC REQUIREMENTS AND OPERATIONAL SAFETY...6 4. INSTALLATION...8 4.1. Way of fixing...8 4.2.

More information

High Precision Quad Output DC Power Supply

High Precision Quad Output DC Power Supply User's Guide High Precision Quad Output DC Power Supply Model 382270 Introduction Thank you for selecting the Extech Model 382270. This device is shipped fully tested and calibrated and, with proper use,

More information

AI531 Analog Input Module

AI531 Analog Input Module Ordering Data DATA SHEET AI531 Analog Input Module 1 Ordering Data Part No. Description Product Life Cycle Phase *) 1SAP 250 600 R0001 AI531, analog input module, 8 AI, U/I/Pt100, TC, 15 bits + sign, 4-wires

More information

General Operating, Maintenance and Installation Manual

General Operating, Maintenance and Installation Manual General Operating, Maintenance and Installation Manual Hardware Platform for Protocol Converter Small Embedded Controller - SEC2-91056 Erlangen Telephone +49 9131 92076-0 Fax: +49 9131 92076-10 Internet:

More information

TG basic 1. Appliance tester for testing protective measures in accordance with DIN VDE (DIN EN 62638)

TG basic 1. Appliance tester for testing protective measures in accordance with DIN VDE (DIN EN 62638) TG basic 1 Appliance tester for testing protective measures in accordance with DIN VDE 0701-0702 (DIN EN 62638) Operating manual (Version 1.00.15 or higher) Table of contents Page 1. Safety information

More information

User's Manual. english

User's Manual. english BES M12EN-PFC40F-S04G-D11 BES M18EN-PFC80F-S04G-D11 BES M18MN-PFC50B-S04G-D11 BES M30EN-PFC15F-S04G-D11 BES M30MN-PFC10B-S04G-D11 Inductive Safety Sensors User's Manual english www.balluff.com Original

More information

USB/RS-485 INTERFACE CONVERTER PD10 TYPE USER S MANUAL

USB/RS-485 INTERFACE CONVERTER PD10 TYPE USER S MANUAL USB/RS-485 INTERFACE CONVERTER PD10 TYPE USER S MANUAL Contents 1. APPLICATION... 5 2. CONVERTER SET... 5 3. CONVERTER INSTALLATION... 6 3.1. Converter installation and safety requirements... 6 3.2. Description

More information

Installation instructions Ethernet switch EC / / 2011

Installation instructions Ethernet switch EC / / 2011 Installation instructions Ethernet switch EC2095 7390731 / 00 02 / 2011 Contents 1 Preliminary note................................................. 3 1.1 Symbols used...............................................

More information

BNI PNT Z015. IP67 Modules 4 IO-Link/In-/Outputs,12 In-/Outputs User s Guide

BNI PNT Z015. IP67 Modules 4 IO-Link/In-/Outputs,12 In-/Outputs User s Guide BNI PNT-502-105-Z015 IP67 Modules 4 IO-Link/In-/Outputs,12 In-/Outputs User s Guide Content 1 Notes 3 1.1. About this guide 3 1.2. Structure of the guide 3 1.3. Typographical Conventions 3 Enumerations

More information

Operating Instructions for Differential Pressure Sensor. Model: PMP

Operating Instructions for Differential Pressure Sensor. Model: PMP Operating Instructions for Differential Pressure Sensor Model: PMP 1. Contents 1. Contents... 2 2. Note... 3 3. Instrument Inspection... 3 4. Regulation Use... 3 5. Operating Principle... 4 6. Mechanical

More information

Technical Manual. cctalk USB Hub CCT 910

Technical Manual. cctalk USB Hub CCT 910 Technical Manual cctalk USB Hub CCT 910 - - June 2010 wh Münzprüfer Berlin GmbH Teltower Damm 276 D - 14167 Berlin Technical Manual CCT 910 wh Münzprüfer Berlin GmbH, Germany Content 1. CCT 910 Overview...4

More information

Accessories for stand-alone gird inverter SMART LOAD 6000

Accessories for stand-alone gird inverter SMART LOAD 6000 Accessories for stand-alone gird inverter SMART LOAD 6000 Technical Description SL6000-TEN081820 98-2001320 Version 2.0 EN Table of Contents Table of Contents 1 Notes on this Manual..............................

More information

NJ-Series Power Supply Unit NJ-PA/PD

NJ-Series Power Supply Unit NJ-PA/PD NJ-Series Power Supply Unit CSM_NJ-PA_PD_DS_E_1_2 Powerful power supply unit to supply stable power to the NJ-series controller. Stable power supply is available from the NJ-series CPU Unit to each I/O

More information

Operating Manual Version: 3.22 February 5, Time-Code-Interface TCI-70

Operating Manual Version: 3.22 February 5, Time-Code-Interface TCI-70 Operating Manual Version: 3.22 February 5, 2004 Time-Code-Interface TCI-70 TABLE OF CONTENTS Page A1 SAFETY INSTRUCTIONS A2 COPYRIGHT A3 CE-DECLARATION A4 GENERAL INFORMATION B OPERATION DESCRIPTION 1

More information

I/O SIGNAL CONDITIONER

I/O SIGNAL CONDITIONER Technical Data Sheet No. TD9809M Rev. F Date of Issue: December 9, 2009 OPERATING MANUAL I/O SIGNAL CONDITIONER CAUTION: THIS PRODUCT DOES NOT PROVIDE GALVANIC ISOLATION. DO NOT ATTEMPT USE OF THIS PRODUCT

More information

CPCI-PS24 24V-Power Supply

CPCI-PS24 24V-Power Supply 24V-Power Supply Hardware Manual to Product I.2301.21 esd electronic system design gmbh Vahrenwalder Str. 207 30165 Hannover Germany http://www.esd.eu Phone: +49 (0) 511 3 72 98-0 Fax: +49 (0) 511 3 72

More information

REDUNDANCY MODULE TSP-REM360 AND TSP-REM600

REDUNDANCY MODULE TSP-REM360 AND TSP-REM600 REDUNDANCY MODULE TSP-REM360 AND TSP-REM600 Operating Instructions Seite 1 Dimensions drawings: TSP-REM360 Weight: 0.882lb Gewicht: 0.40kg Seite 2 Dimensions drawings: TSP-REM600 Bottom view Top view Side

More information

AEW Pulse Adapter. Building Technologies

AEW Pulse Adapter. Building Technologies 5 383 Pulse Adapter AEW310.2 The AEW310.2 pulse adapter acquires and handles the pulses from 1 or 2 consumption meters with pulse output and transmits the data to an M-Bus-network. For setting the parameters,

More information

BNI PNT Z015. IP67 Modules 16 Input User s Guide

BNI PNT Z015. IP67 Modules 16 Input User s Guide BNI PNT-104-105-Z015 IP67 Modules 16 Input User s Guide Content 1 Notes 3 1.1. About this guide 3 1.2. Structure of the guide 3 1.3. Typographical Conventions 3 Enumerations 3 Actions 3 Syntax 3 Cross-references

More information

Installation- and Operating instructions for CU CP-Link 4 transmitter box The Two Cable Display Link. Version: 1.

Installation- and Operating instructions for CU CP-Link 4 transmitter box The Two Cable Display Link. Version: 1. Installation- and Operating instructions for CU8802-0000 CP-Link 4 transmitter box The Two Cable Display Link Version: 1.1 Date: 2015-08-27 Table of contents Table of contents 1 Foreword 3 1.1 Notes on

More information

Assembly Instructions scancontrol 2700/2750 (500)

Assembly Instructions scancontrol 2700/2750 (500) Assembly Instructions scancontrol 2700/2750 (500) 1. Warnings Connect the power supply and the display-/output device in accordance with the safety regulations for electrical equipment. The power supply

More information

HST -TS1 Guard-locking mechanism (Translation of Original Manual)

HST -TS1 Guard-locking mechanism (Translation of Original Manual) Installation and Operating Manual for Components HST -TS1 Guard-locking mechanism (Translation of Original Manual) HST-TS1 Ident.-No.: 10250 HST-TS1 Ident.-No.: 10252 HST-TS1 Ident.-No.: 10251 HST-TS1

More information

Pressure Transmitters with IO-Link BSP-Bxxx-xx004-xxxS1A-xx, BSP-Vxxx-xx004-xxxS1A-xx

Pressure Transmitters with IO-Link BSP-Bxxx-xx004-xxxS1A-xx, BSP-Vxxx-xx004-xxxS1A-xx EU Directive 2004/108/EC (EMC Directive) and EMC Law Generic Standards: EN 61000-6-4 (Emissions), EN 61000-6-2 (Interference Immunity) Emissions testing: Radio interference emissions EN 55011 Group 1,

More information

LED Driver Linear / area dimming. Driver LC 50W mA 54V 0-10V lp EXC UNV EXCITE series SELV

LED Driver Linear / area dimming. Driver LC 50W mA 54V 0-10V lp EXC UNV EXCITE series SELV Driver LC 50W 350 1050mA 54V 0-10V lp EXC UNV EXCITE series SELV Product description Constant current LED Driver Dimmable via 0... 10 V interface Dimming range 1 100 % Adjustable output current between

More information

Products no longer available

Products no longer available echnical data sheet NV4-MF(-) Modulating linear actuator for -way and 3-way globe valves Actuating force 1000 N Nominal voltage AC/DC 4 V Modulating control DC 0... 10 V Position osition feedback feedbac

More information

CM597 Ethernet Communication Module

CM597 Ethernet Communication Module Ordering Data DATA SHEET CM597 Ethernet Communication Module 1 Ordering Data Part No. Description Product Life Cycle Phase *) 1SAP 173 700 R0001 1SAP 373 700 R0001 CM597-ETH, communication module Ethernet

More information

EXD-TEVI Economizer Controller for Tandem Compressors

EXD-TEVI Economizer Controller for Tandem Compressors Technical Bulletin EXD-TEVI is a stand-alone controller for enhanced wet vapor injection for Copeland tandem Scroll compressors in heating applications. Features EXD-TEVI Emerson solution for specified

More information

Instruction Manual PU/PI and PS10 Differential Pressure Transducers

Instruction Manual PU/PI and PS10 Differential Pressure Transducers Instruction Manual PU/PI and PS10 Differential Pressure Transducers halstrup-walcher GmbH Stegener Straße 10 D-79199 Kirchzarten Germany Phone: +49 (0) 76 61/39 63 0 Fax: +49 (0) 76 61/39 63 99 E-Mail:

More information

LZR - U920/-U921. LASER MEASUREMENT DEVICE with bidirectional bus communication. User s Guide for product version 0500 and more

LZR - U920/-U921. LASER MEASUREMENT DEVICE with bidirectional bus communication. User s Guide for product version 0500 and more EN LZR - U920/-U92 LASER MEASUREMENT DEVICE with bidirectional bus communication User s Guide for product version 0500 and more 2 LASER MEASUREMENT DEVICE Other use of the device is outside the permitted

More information

Products no longer available

Products no longer available echnical data sheet NVF4-MF(-E)-R Modulating linear actuator with emergency function for -way and 3-way globe valves Actuating force 800 N Nominal voltage AC/DC 4 V Modulating control DC 0... 10 V Position

More information

Operating instructions. Monitor FS-2 / FS-2N / / 2013

Operating instructions. Monitor FS-2 / FS-2N / / 2013 Operating instructions Monitor FS-2 / FS-2N UK 7390959 / 00 01 / 2013 Contents 1 Preliminary note...4 1.1 Symbols used...4 1.2 Warning signs used...4 2 Safety instructions...5 2.1 General...5 2.2 Target

More information

User Manual SP4-4K. 4K HDMI Splitter 1x4. All Rights Reserved. Version: SP4-4K_2016V1.0

User Manual SP4-4K. 4K HDMI Splitter 1x4. All Rights Reserved. Version: SP4-4K_2016V1.0 User Manual SP4-4K 4K HDMI Splitter 1x4 All Rights Reserved Version: SP4-4K_2016V1.0 SAFETY PRECAUTIONS To insure the best from the product, please read all instructions carefully before using the device.

More information

GmbH, Stettiner Str. 38, D Paderborn

GmbH, Stettiner Str. 38, D Paderborn AnDi 1 to AnDi 4 A/D Converter for M-Bus (Valid from M-Bus generation: $31) Art. no. MB AnDi 1 Art. no. MB AnDi 2 Art. no. MB AnDi 3 Art. no. MB AnDi 4 1 channel A/D converter for M-Bus 2 channel A/D converter

More information

Instruction Manual FH EXT

Instruction Manual FH EXT Sensor Outside Our FH series models are divided into four categories, see table below: Thank you for buying a SAUTER force gauge. We hope you are pleased with your high quality force gauge with its big

More information

BNI IOL K006 BNI IOL K006-C01 BNI IOL-302-S01-K006 BNI IOL-302-S01-K006-C01. IO-Link 1.1 Sensor-Hub / Actuator-Hub User s Guide

BNI IOL K006 BNI IOL K006-C01 BNI IOL-302-S01-K006 BNI IOL-302-S01-K006-C01. IO-Link 1.1 Sensor-Hub / Actuator-Hub User s Guide BNI IOL302000K006 BNI IOL302000K006C01 BNI IOL302S01K006 BNI IOL302S01K006C01 IOLink 1.1 SensorHub / ActuatorHub User s Guide Content 1 Notes to the user 2 1.1 About this guide 2 1.2 Structure of the guide

More information

PHOENIX CONTACT - 07/2006

PHOENIX CONTACT - 07/2006 Buffer module with maintenance-free capacitor-based power storage device INTERFACE Data sheet 102035_03_en PHOENIX CONTACT - 07/2006 Description Short-term mains interruptions are bridged by QUINT BUFFER,

More information

User Manual SP2-4K. 4K HDMI Splitter 1x2. All Rights Reserved. Version: SP2-4K_2016V1.0

User Manual SP2-4K. 4K HDMI Splitter 1x2. All Rights Reserved. Version: SP2-4K_2016V1.0 User Manual SP2-4K 4K HDMI Splitter 1x2 All Rights Reserved Version: SP2-4K_2016V1.0 SAFETY PRECAUTIONS To insure the best from the product, please read all instructions carefully before using the device.

More information

ATS22D17Q soft starter-ats22-control 220V-power 230V (4kW)/ V(7.5kW)

ATS22D17Q soft starter-ats22-control 220V-power 230V (4kW)/ V(7.5kW) Product datasheet Characteristics ATS22D17Q soft starter-ats22-control 220V-power 230V (4kW)/400...440V(7.5kW) Complementary Assembly style Function available Supply voltage limits Main Range of product

More information

Handbook ASI-PRG-ADR. AS-Interface Addressing Device. Festo AG & Co de 0004a

Handbook ASI-PRG-ADR. AS-Interface Addressing Device. Festo AG & Co de 0004a Handbook ASI-PRG-ADR AS-Interface Addressing Device Festo AG & Co. 360 039 de 0004a AS-Interface is a registered Trademark of the AS-International Association We recognise a duty to make a contribution

More information

Issue 03/2013. The Electronic Load

Issue 03/2013. The Electronic Load Issue 03/2013 ZS Electronic Loads, PL Series Interface overview RS-232 USB / GPIB LAN System bus Analog X Analog isolated / X Standard ption / not available PL506 PL1006 Voltage Current Resistance 3) Model

More information

BNI PBS Z001. IP67 module, Profibus IO-Link Master Short Guide

BNI PBS Z001. IP67 module, Profibus IO-Link Master Short Guide BNI PBS-502-001-Z001 IP67 module, Profibus IO-Link Master Short Guide 1 Notes for the User 1.1 About this guide 2 1.2 Structure of the guide 2 1.3 Typografical conventions 2 1.3.1 Enumerations 2 1.3.2

More information

ATS22D17Q soft starter-ats22-control 220V-power 230V(4kW)/ V(7.5kW)

ATS22D17Q soft starter-ats22-control 220V-power 230V(4kW)/ V(7.5kW) Characteristics soft starter-ats22-control 220V-power 230V(4kW)/400...440V(7.5kW) Main Range of product Altistart 22 Product or component type Product destination Product specific application Component

More information

Instruction Manual FH EXT

Instruction Manual FH EXT Set Thank you for buying a SAUTER force gauge. We hope you are pleased with your high quality force gauge with its big functional range. If you have any queries, wishes or helpful suggestions, do not hesitate

More information

Original operating instructions Fail-safe inductive sensor GG711S

Original operating instructions Fail-safe inductive sensor GG711S Original operating instructions Fail-safe inductive sensor GG7S 8236522 / 2 / 26 Contents Preliminary note...3. Symbols used...3.2 Warning signs used...3 2 Safety instructions...4 2. Safety-related requirements

More information

Instruction Manual Wally Box II Digital - Pneumatic - Calibrator IM DE (WIKA)

Instruction Manual Wally Box II Digital - Pneumatic - Calibrator IM DE (WIKA) Instruction Manual Wally Box 65-2000-II Digital - Pneumatic - Calibrator IM.650.226DE (WIKA) IM.650.226DE (Issue 1-07/02) 25.07.01 1 Safety Information:! Operate the instrument with the plug-in power supply

More information

FT-20 Fire Training Fog Machine User Manual English

FT-20 Fire Training Fog Machine User Manual English FT-20 Fire Training Fog Machine User Manual English 2017 Antari Lighting and Effects Ltd. 1 User Manual - English Safety Information Please read the following safety information carefully before operating

More information

FR-IB100/PCIe. FlexRay PCI Express Interface Card USER MANUAL ENGLISH

FR-IB100/PCIe. FlexRay PCI Express Interface Card USER MANUAL ENGLISH FR-IB100/PCIe FlexRay PCI Express Interface Card USER MANUAL 4.01.0103.20000 2.0 ENGLISH Important User Information Liability Every care has been taken in the preparation of this document. Please inform

More information

QXA2000 QXA2001. Condensation Monitor QXA2001 QXA2000 AQX2000

QXA2000 QXA2001. Condensation Monitor QXA2001 QXA2000 AQX2000 1 542 1542P03 1542P01 1542P02 QXA2001 QXA2000 AQX2000 Condensation Monitor QXA2000 QXA2001 The QXA2000 condensation monitor is used to avoid damage due to condensation on chilled ceilings and in HVAC plant.

More information

RGB Power Batten. User Manual. Order code: EQLED032

RGB Power Batten. User Manual. Order code: EQLED032 RGB Power Batten User Manual Order code: EQLED032 Safety advice WARNING FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL CARE- FULLY BEFORE YOUR INITIAL START-UP! Before your initial start-up, please

More information

VDI Pro Voltage & Dry Contact Interface Installation and programming Guide MODEL VDI MK2

VDI Pro Voltage & Dry Contact Interface Installation and programming Guide MODEL VDI MK2 VDI Pro Voltage & Dry Contact Interface Installation and programming Guide MODEL VDI MK2 1 of 18 PREFACE Important Installation Information It is the purchasers responsibility to determine the suitability

More information