ULTRA QUICK FUSES FOR PROTECTION OF SEMICONDUCTORS POWER NEEDS CONTROL
|
|
- Simon Richard
- 5 years ago
- Views:
Transcription
1 GENERAL INFORMATION SYSTEM D0 SYSTEM D SYSTEM C SYSTEM BS SYSTEM NV/NH ACCESSORIES CHARACTERISTICS INDEX FUSES FOR PROTECTION OF SEMICONDUCTORS POWER NEEDS CONTROL
2 Typical applications protected by Ultra Quick fuse-links more info in Ultra Quick industry application.pdf DC drives Power controls Soft- starters AC servo regulators-brushless Frequency inverters Thyristor switches UPS Variable power regulators Power rectifires Voltage regulators SSRsemiconductor relays Welding inverters Solbrakes Temperature controlers Batery chargers Solar power Traction inverters Wind power
3 Ultra Quick Cross-Reference The products on this cross-reference table are some of the most commonly used fuses for semiconductor protection. Cylindrical ETI Bussmann Ferraz Siba SIZE x 8 CH/A/00V FWC-AF E CH/8A/00V FWC-8AF F CH/A/00V FWC-AF G CH/A/00V FWC-AF H CH/A/00V FWC-AF J CH/0A/00V FWC-0AF K CH/A/00V FWC-AF L CH/A/00V FWC-AF V078 - SIZE x CH/A/90V FWP-AF T CH/A/90V CH/A/90V FWP-AF W CH/0A/90V FWP-0AF X CH/A/90V FWP-AF Y CH/A/90V FWP-AF Z CH/0A/90V FWP-0AF A CH/0A/90V FWP-0AF B SIZE x 8 CH/0A/90V FWP-0AF CH/A/90V FWP-AF B CH/A/90V FWP-AF Z CH/0A/90V FWP-0AF S CH/0A/90V FWP-0AF W CH/A/90V FWP-AF T CH/80A/90V FWP-80AF A CH/0A/00V FWP-0AF Y BS88 part 90V ETI Bussmann Ferraz GE BS7 BS7//A/90V ET J0788 GSB BS7//A/90V ET K0788 GSGB0 BS7//A/90V FE - GSGB BS7//0A/90V FE0 - GSGB0 BS7//A/90V FE - GSGB BS7//0A/90V FE0 - GSGB BS7//A/90V ET - GSGB BS7//A/90V FE - GSGB BS7//7A/90V FE7 - - BS7//80A/90V FE80 - GSGB80 BS7//90A/90V FE90 - GSGB8 BS7//0A/90V FE0 - - BS7D BS7D/70/90A/90V EET90 A09999 GSGB8 BS7D/70/A/90V EET B09999 GSGB BS7D/70/A/90V FEE B09999 GSGB BS7D/70/A/90V FEE J BS7D/70/A/90V FEE K07909 GSGB BS8 BS8/8/A/90V MT Q097 GSB0 BS8/8/80A/90V FM80 - GSGB70 BS8/8/00A/90V FM00 - GSGB90 BS8/8/0A/90V FM0 - GSGB BS8/8/A/90V FM - GSGB00 BS8/8/0A/90V FM0 - GSGB BS8T BS8T/8/00A/90V MMT00 F BS8T/8/A/90V MMT J BS8T/8/A/90V MMT K BS8T/8/A/90V MMT S BS8T/8/00A/90V FMM BS8T/8/0A/90V FMM0 - GSGB00 BS8T/8/00A/90V FMM00 - GSGB00 BS8T/8/0A/90V FMM0 - - BS8T/8/700A/90V FMM Square body type M: DIN 0 90V ETI Bussmann Ferraz Siba SIZE 00C M00/A/90V 70M X0 - M00/0A/90V 70M B07 - M00/0A/90V 70M F0 - M00/A/90V 70M8 K0 - M00/80A/90V 70M Q009 - M00/0A/90V 70M7 V00 - M00/A/90V 70M8 X00 - M00/A/90V 70M9 N009 - M00/00A/90V 70M70 D007 - M00/0A/90V 70M7 H007 - SIZE M/A/90V 70M8 M M/80A/90V 70M8 K M/0A/90V 70M8 W M/A/90V 70M8 Y M/A/90V 70M8 C M/00A/90V 70M8 E M/0A/90V 70M8 J M/A/90V 70M87 N M/0A/90V 70M88 P M/00A/90V 70M89 S SIZE M/00A/90V 70M808 B M/0A/90V 70M809 D M/00A/90V 70M8 F M/0A/90V 70M8 H SIZE M/00A/90V 70M808 P M/0A/90V 70M8 R M/7A/90V 70M8 S M/800A/90V 70M8 T Square body type G: DIN 90V ETI Bussmann Ferraz Siba SIZE GM/0A/90V 70M9 Y000C 0 0 GM/A/90V 70M0 M0C 0 0 GM/0A/90V 70M A0008C 0 0 GM/00A/90V 70M B0009C 0 0 GM/0A/90V 70M S0000C 0 0 GM/00A/90V 70M T0000C 0 0 GM/0A/90V 70M H GM/0A/90V 70M W00008C 0 0 GM/7A/90V 70M7 K SIZE GM/00A/90V 70M0 K0007C 0 GM/0A/90V 70M R00 0 GM/0A/90V 70M L0008C 0 GM/7A/90V 70M N00070C 0 GM/800A/90V 70M P0007C 0 GM/900A/90V 70M W008 0 GM/00A/90V 70M X009 0 SIZE GM/0A/90V 70M0 X GM/7A/90V 70M Y00079C 0 GM/800A/90V 70M Z00080C 0 GM/900A/90V 70M B000 0 GM/00A/90V 70M B0008C 0 GM/0A/90V 70M D0008C 0 GM/0A/90V 70M7 F00 0 Square body type S: DIN 90V ETI Bussmann Ferraz Siba SIZE 00C S00C/80/A/90V 70M R07C S00C/80/80A/90V 70M A S00C/80/0A/90V 70M L S00C/80/A/90V 70M M S00C/80/A/90V 70M N S00C/80/00A/90V 70M7 P S00C/80/0A/90V 70M8 B S00C/80/A/90V 70M9 A S00/80/0A/90V 70M70 B S00/80/00A/00V 70M7 E SIZE SM//0A/90V 70M09 J0000C 0 7 SM//A/90V 70M K000C 0 7 SM//0A/90V 70M L0C 0 7 SM//00A/90V 70M A007C 0 7 SM//0A/90V 70M M000C 0 7 SM//00A/90V 70M N000C 0 7 SM//0A/90V 70M P000C 0 7 SM//0A/90V 70M Q000C 0 7 SM//7A/90V 70M7 R0007C 0 7 SIZE SM//00A/90V 70M S008C 0 7 SM//0A/90V 70M S0089C 0 7 SM//0A/90V 70M T0090C 0 7 SM//7A/90V 70M R0007C 0 7 SM//800A/90V 70M H00709C 0 7 SM//900A/90V 70M X009C 0 7 SM//00A/90V 70M Y009C 0 7 SIZE SM//0A/90V 70M V000C 0 77 SM//7A/90V 70M W00C 0 77 SM//800A/90V 70M X00C 0 77 SM//900A/90V 70M Y009C 0 77 SM//00A/90V 70M Y SM//0A/90V 70M B00C 0 77 SM//0A/90V 70M7 C007C 0 77
4 Ultra Quick Application
5 Support for Ultra Quick Cross-reference on internet for MRO (maintenance replacement operation) Find fuse, technical data in catalogue by press button Search ETI part number Software Ultra Quick select for OEM (original equipment manufacturer) Application guide
6 Fuses for semiconductor devices protection General information Fuses are the oldest protective devices in the electrical industry. Because of the advantageous features, fuses have been and are used in an extensive fields of applications one of them is protection of semiconductor devices (diodes, thyristors, power transistors, GTO) in current and frequency converters. Semiconductor devices are being produced with high maximum continuous currents and peak inverse voltages. Unfortunately, that devices still have poor overload capacities and continue to need sensitive and fast-acting protection. ETI fuses for semiconductor protection series ULTRA-QUICK are optimal solution for the protection of power semiconductors. General informations about fuse marking Fuse marking consists of two letters, where the first letter describes the breaking ranges a - partial range Opearates by all currents between the lowest current indicated on its operating time current characteristic and its rated breaking capacity. g - full range Opearates by all currents which cause the melting of the fuse element up to its rated breaking capacity The second letter describes the applications (characteristics or utilization category). L mainly for conductor protection B mining equipment M motor circuit and switching devices protection R semiconductor protection Tr transformers protection The combination of breaking ranges and applications indicate many combinations describes in standards and technical report IEC TR 88 Application-guide for low voltage fuses gl: Full range - general application, mainly for conductor protection am: Partial range (back-up) - short-circuit protection of motor circuit gr, gs: Full range - semiconductor protection ar: Partial range (back-up) - semiconductor protection gb: Full range - mining equipment protection gtr: Full range - transformer protection ETI fuses for semiconductor protection series ULTRA-QUICK comply with the IEC 09 and VDE 0 series standard. A list of the standards for characteristics and dimensions is included below: IEC 09-: Supplementary requirements for fuselinks for the protection of semiconductor devices IEC 09--: Examples of standardized fuses IEC 09--: Supplementary requirements for fuses for use by unskilled persons (fuses mainly for householdand similar applications) IEC 09--: Supplementary requirements for fuses for use by authorized persons (fuses mainly for industrial application) for the protection of semiconductor devices DIN 0, DIN VDE 0-0 Niederspannungssicherungen (NH-System) DIN EN 09-, VDE 0 Teil 0 Niederspannungssicherungen Teil : Zusätliche Anforderung an BS 88 Part Fuse-links as protective equipment for semiconductors should ensure that the following conditions are met: - Interruption should be effected quickly enough to prevent damage to other devices - Interruption should take place before damage to semiconductor devices quick action - High rated breaking capacity - High d.c. switching capacity - High current limitation - Operation of the protective equipment should not cause unacceptably high over-voltages to be impressed on any of the semiconductor devices low arc voltage Selecting the fuses for semiconductor protection (FSP) What the user should know about FSP to be able to select the best FSP for his special purpose? In practice, there exist no common regulations covering FSPs, except IEC0- Applications guide for the protection of semiconductor convertors against overcurrent by fuses. The object of this report is to advise on the specific fuse features and on the specific convertor features which are to be observed to ensure correct application of FSP in convertors, and to give specific recommendations for trouble-free operation of convertors protected by fuses. Before the fuse selection the user must be fully aware of the conditions under which the FSP is to function. This applies to normal service conditions as well as to conditions during fault. Here is few basic suggestions for FSP selection: A: The load current through the semiconductor (Isem) should be lower or equal as the rated current of the selected fuse-link (Inv). For continuous duty the FSP can withstand this current indefinetly. In case of pulsed current, the user should consult ETI. I sem I nv B: The operating voltage on the semiconductor (Usem) should be lower or equal as the rated voltage of the fuselink (Unv). Consult ETI with respect to a.c. and d.c. applied voltage, time constant and power factor. U sem U nv C: The operating (pre-arcing + arcing) I t values of the selected fuse-link (I t opv ) should be lower than I t of the semiconductor (I t sem ). Consult ETI with respect to parallel operation, discrimination and loss of coordination at higher fault levels I t opv < I t sem D: For other current rating, which are not included in this catalogue, please consult ETI R&D department.
7 Short product range review of fuses for semiconductor protection series ULTRA-QUICK Systems Types Sizes Rated current Rated voltage Characteristic Pages D0 D0, D0 A A 00V gr D DI, DII, DIII, DIV, DV A 00A 00V gr 7 CH A A 00V ar 8 C CH, CH-S A - 0A 90V ar 8 CH, CH-S 0A 0A 90V ar 8 BS BS8, BS7, BS8, BS8T A - 800A 0V ar 9 BS8, BS7, BS7D, BS8, BS8T A - 700A 90V ar NV/NH 0 ka NV/NH 00 ka M 00C, 00, 0,,, A 0A 90V ar/gr - S80mm 00C, 00 A A 90V ar/gr S97mm 0 A A 90V ar/gr Smm,, A 0A 90V ar/gr M 00 A 0A 90V ar,, A 800A 90V ar S80mm 00C, 00 A 00A 90V ar 7,, 80A - 0A 90V ar 8 Smm,, 80A 0A 90V ar 9 G,, 80A 0A 90V ar 0 M 0 A A 00V ar,, 80A 0A 0V ar S80mm 00 A A 00V ar S 0 A - A 00V ar Smm,, A 0A 00V ar G,, A 0A 00V ar M, striker 00C A A 90V gr 7,, A 0A 90V gr 8 M, S0mm, a 800A 0A 00V gr 9 S80mm 00C A A 90V gr 0 Smm,, 80A 0A 90V gr G,, A 0A 00V gr M 00C, 00 A-A 90V gs,, A - 0A 90V gs Smm,, A-0A 90V gs Accessories -7
8 Marking of fuses for semiconductor protection series ULTRA-QUICK:. System D and D0 D0-fuse links D-fuse links D0 UQ A DI UQ A D0 max. A DII max. 00A size trade mark current DIII DIV DV trade mark size current. System BS and NV/NH BS - fuse links NV/NH - fuse links BS 8 UQ 8 A 0V S 00 M UQ U /80 /A /90V 7 max. 800A 90V M 0 * U-N max. 0A 7D 9 G 00C 97 00V 00V type 8 0V 8T diameter (T-twin, D-double) trade mark 70 8 length current voltage type a size micro-switch trade mark 0kA breaking capacity distance current voltage. System C CH - fuse links CH UQ /A /00V CH-S max. 0A 90V 00V type size trade mark current voltage
9 Operation indicators of ULTRA-QUICK fuse links The operation-sensing device is a fine wire which is connected in parallel with the fuse melting element. This wire is used to hold in a flag (made of thin metal band) usually placed on the upper cover. When the wire breaks because of fuse operate, the flag is pushed out and in this way an indication of operation is given. The indicator on pic. is a visual indication of fuse operating. When only indication is not enough, we offering possibility to add a microswitch NVS on the upper cover for remote signalling of fuse operating (Pic.). Indicator Microswitch NVS Another type of signalling of fuse operating is indicator, called middle. It is located in the center of the ceramic body in front of the fuse link. After fuse operation, the particular plastic striker is pushed out from the ceramic body (Pic.). Pic. Pic. Indicator Microswitch MK For remote signaling we offering microswitch MK (Pic. and Pic.) mounted on additional adapters AMK (Pic. and Pic. 7) Pic. Pic. Pic. Pic. Pic. 7 Fuse link Pic. 8 The purpose of adapters AMK and AMK are microswitch type MK setting up on the fuse link body of sizes for 90V and 00V.
10 SYSTEM D0 Technical data on page 8 gr ~00V RATED VOLTAGE D0UQA Technical data: Standards: IEC 09- Breaking capacity: ~0kA / 8kA Rated voltage: ~00V / 0V Application: Fuse-links of system D0 are applied in fuse base E and E8 and fuse-switch disconnectors VLD0 and STV D0. D0UQ0A Size In (A) Type Code No. D0 D0 I t-value (A s) Power dissipation (W) Char. Colour Dimension A Packaging (pcs) Weight (g) D0UQA 000,, gr pink 7. /00 D0UQA 000, gr brown 7. /00 D0UQA 000 0,0 gr green 7. /00 D0UQA 000, gr red 8. /00 D0UQA , gr grey 9.7 /00 0 D0UQ0A ,0 gr blue.9 /00 D0UQA ,0 gr brown. /00 D0UQA ,0 gr black. /00 0 D0UQ0A ,0 gr white. /00 D0UQA ,0 gr copper.9 /00 Dimensions: QUICK D0 D0 remember The standard IEC defines two types of co-ordination according to the expected level of service continuity. The standard IEC 097-, general rule are applicable to this standard, where specifically called for. Type : Coordination requires that, under short-circuit conditions, the device shall cause no danger to persons or installation and may not be suitable for further service withouth repair and replacement of parts. Type : Coordination requires that, under short-circuit conditions, the device shall cause no danger to persons or installation and shall be suitable for further use. For hybrid controllers and starters, the risk of contact welding is recognized in which case the manufacturer shall indicate the measures to be taken as regards the maintenance of the equipment. Note: When using a softstarter in a type co-ordination, replacing the fuses and restart has to be accepted after a short-circuit. Only»fuses for semiconductor protection«can be used to achieve a type coordination for soft-starters. For more information visit: products/semiconductor protection
11 Technical data on page 9 RATED VOLTAGE gr ~00V SYSTEM D Technical data: Standards: IEC 09- Breaking capacity: ~0kA / 8kA Rated voltage: ~00V / V Application: Fuse-links of system D are mounted in fuse base E, E7, E, R /, R. DIUQA Size In (A) Type Code No. I t-value (A s) Power dissipation (W) Char. Colour Dimension B Packaging (pcs) Weight (g) DIUQA 000,8, gr pink /00 DIUQA 000, gr brown /00 D I DIUQA 000 8, gr green /00 DIUQA 000 0, gr red 8 /00 DIUQA 000 0, gr grey /00 0 DIUQ0A , gr blue /00 DIUQA ,0 gr yellow /00 DIIUQA 0000,8, gr pink /00 7 DIIUQA 0000, gr brown /00 7 DIIUQA , gr green /00 7 D II DIIUQA , gr red 8 /00 7 DIIUQA , gr grey / DIIUQ0A , gr blue /00 9 DIIUQA ,0 gr yellow / DIIUQ0A 00008,0 gr black /00 0 D III DIIIUQA ,0 gr black / DIIIUQ0A ,0 gr white 8 /00 9 DIIIUQA ,0 gr copper 0 /00 D IV 80 DIVUQ80A ,0 gr silver /8 0 DIVUQ0A ,0 gr red 7 /8 D V DVUQA ,0 gr yellow /0 8 DVUQA ,0 gr copper 7 /0 00 DVUQ00A ,0 gr blue 9 /0 DIIUQA DIIIUQA Dimensions: DI DII DIII DIVUQ80A DIV DV DVUQ00A For more information visit: products/semiconductor protection 7
12 SYSTEM NV-NH C SERIES TYPES ar RATED VOLTAGE UQ0 M CH, CH-S ~ 00V ~90V RATED VOLTAGE Technical data on page 0 Technical data: Standards: IEC 09- Breaking capacity: ~00 ka Rated voltage: ~00V,~90V Application: Fuse-links of system C are applied in fuse disconnectors VLC and PCF. CH CH Size x8 x x8 Type without indicator I t-value (A s) Power dissipation(w) Type with striker Code No. ETI Char. In (A) Code No. ETI CHUQ/A/00V , - ar 8 CHUQ/8A/00V ar CHUQ/A/00V , - ar CHUQ/A/00V ar CHUQ/A/00V , - ar 0 CHUQ/0A/00V 000 0,8 - ar CHUQ/A/00V ar CHUQ/A/00V , - ar CHUQ/A/90V CH-S/A/90V 007 ar. CHUQ/A/90V CH-S/A/90V 008 ar. CHUQ/A/90V , CH-S/A/90V 009 ar. 0 CHUQ/0A/90V CH-S/0A/90V 00 ar. CHUQ/A/90V CH-S/A/90V 00 ar. CHUQ/A/90V , CH-S/A/90V 00 ar. 0 CHUQ/0A/90V CH-S/0A/90V 007 ar. 0 CHUQ/0A/90V CH-S/0A/90V 009 ar. 0 CHUQ/0A/90V 000 0, CH-S/0A/90V 00 ar CHUQ/A/90V 000, CH-S/A/90V 00 ar CHUQ/A/90V CH-S/A/90V 00 ar 0 CHUQ/0A/90V , CH-S/0A/90V 007 ar 0 CHUQ/0A/90V , CH-S/0A/90V 009 ar CHUQ/A/90V CH-S/A/90V 00 ar 80 CHUQ/80A/90V , CH-S/80A/90V 00 ar 0 CHUQ/0A/00V CH-S/0A/00V 00 ar CH -A (700V DC/breaking capacity 0kA) A (00V DC/breaking capacity 0kA) CH, CH-S 700V DC/breaking capacity 0kA CH, CH-S 00V DC/breaking capacity 0kA Pack. (pcs.) Weight (g) Dimensions: CH and CH-S Size a b c d x8 8,, x,8, 7, x8 8,, For more information visit: products/semiconductor protection 8
13 Technical data on page SERIES TYPESRATED VOLTAGE RATED VOLTAGE ar UQ0 M ~0V ~ 00V SYSTEM NV-NH SYSTEM BS Technical data: Standards: BS88: Part IEC 09- Breaking capacity: ~0kA / 0kA Rated voltage: ~0V / V Application: Fuse-links of system BS are mounted by screws to busbars. I t-value (A s) Power dissipation (W) Packaging (pcs) Weight (g) Size In (A) Type Code No. Char. BS8UQ/8/A/0V ar. BS8 BS8UQ/8/A/0V , ar. BS8UQ/8/A/0V , ar. BS8UQ/8/A/0V , ar. 0 BS8UQ/8/0A/0V ar. BS7 BS8 BS8T BS7UQ//A/0V ,7 ar BS7UQ//A/0V , ar BS7UQ//A/0V , ar 0 BS7UQ//0A/0V , ar BS7UQ//A/0V , ar 80 BS7UQ//80A/0V ar 0 BS7UQ//0A/0V , ar BS7UQ//A/0V ar BS7UQ//A/0V , ar 80 BS7UQ//80A/0V ar BS8UQ/9/A/0V ar BS8UQ/9/00A/0V , ar 80 0 BS8UQ/9/0A/0V ar 80 BS8UQ/9/A/0V , ar 80 BS8UQ/9/A/0V ar BS8UQ/9/00A/0V ar 80 0 BS8UQ/9/0A/0V , ar BS8TUQ/9/00A/0V ar BS8TUQ/9/00A/0V ar 70 0 BS8TUQ/9/0A/0V ar 70 7 BS8TUQ/9/7A/0V ar BS8TUQ/9/800A/0V ar 70 Note: brand name Italweber Dimensions: BS8 BS7 BS8 BS8T For more information visit: products/semiconductor protection 9
14 SYSTEM NV-NH BS SERIES TYPES RATED VOLTAGE ar UQ0 M ~ 00V ~90V RATED VOLTAGE Technical data on page 7 Technical data: Standards: BS88: Part IEC 09- Breaking capacity: ~0kA / 0kA Rated voltage: ~90V / 0V Application: Fuse-links of system BS are mounted by screws to busbars. I t-value (A s) Power dissipation (W) Packaging (pcs) Weight g) Size In (A) Type Code No. Char. BS8UQ//A/90V ar 8 BS8 BS8UQ//A/90V ar 8 BS8UQ//A/90V ar 8 BS8UQ//A/90V ar 8 0 BS8UQ//0A/90V ar 8 BS7 BS7D BS8 BS8T BS7UQ//A/90V ,8 ar BS7UQ//A/90V ,8 ar BS7UQ//A/90V , ar 0 BS7UQ//0A/90V ar BS7UQ//A/90V , ar 0 BS7UQ//0A/90V , ar BS7UQ//A/90V , ar BS7UQ//A/90V , ar 7 BS7UQ//7A/90V ar 80 BS7UQ//80A/90V , ar 90 BS7UQ//90A/90V , ar 0 BS7UQ//0A/90V ar 90 BS7DUQ/70/90A/90V , ar 90 BS7DUQ/70/A/90V ar 90 BS7DUQ/70/A/90V ar 90 BS7DUQ/70/A/90V , ar 90 BS7DUQ/70/A/90V ar 90 BS8UQ/8/A/90V ,7 ar 0 80 BS8UQ/8/80A/90V ar 0 00 BS8UQ/8/00A/90V ar 0 0 BS8UQ/8/0A/90V ar 0 BS8UQ/8/A/90V ar 0 0 BS8UQ/8/0A/90V ar 0 00 BS8TUQ/8/00A/90V ar 0 BS8TUQ/8/A/90V ar 0 BS8TUQ/8/A/90V ar 0 BS8TUQ/8/A/90V ar 0 00 BS8TUQ/8/00A/90V ar 0 0 BS8TUQ/8/0A/90V ar 0 00 BS8TUQ/8/00A/90V ar 0 0 BS8TUQ/8/0A/90V ar BS8TUQ/8/700A/90V ar 0 Dimensions: Note: brand name Italweber BS8 BS7 BS7D BS8 BS8T For more information visit: products/semiconductor protection
15 Technical data on page TYPES SERIES TYPES RATED VOLTAGE RATED VOLTAGE ar/gr M UQ0 M ~90V ~ 00V SYSTEM NV/NH NV-NH Technical data: Standards: IEC 09- Breaking capacity: ~0kA / ka Rated voltage: ~90V / 0V Application: Fuse-links type M are applied in fuse base (for example) PK. Size 00C 00 0 Dimensions: Type (visual indicator with grip for microswitch NVS ) I t-value (A s) Power dissipation (W) Packaging (pcs) In (A) Code No. Char. Weight (g) M00CUQU-N/A/90V 008 9,8 gr / 80 M00CUQU-N/A/90V 009, gr / 80 M00CUQU-N/A/90V 000, gr / 80 0 M00CUQU-N/0A/90V gr / 80 M00CUQU-N/A/90V 00 90,8 gr / 80 M00CUQU-N/A/90V gr / 80 0 M00CUQU-N/0A/90V gr / 80 0 M00CUQU-N/0A/90V gr / 80 M00CUQU-N/A/90V gr / M00CUQU-N/80A/90V gr / 80 0 M00CUQU-N/0A/90V gr / 80 M00CUQU-N/A/90V gr / 80 M00UQU-N/A/90V 00 8,8 gr /90 80 M00UQU-N/A/90V 00 0, gr /90 80 M00UQU-N/A/90V 00 70, gr / M00UQU-N/0A/90V 00 0 gr /90 80 M00UQU-N/A/90V 00 0,8 gr /90 80 M00UQU-N/A/90V gr / M00UQU-N/0A/90V gr / M00UQU-N/0A/90V gr /90 80 M00UQU-N/A/90V gr / M00UQU-N/80A/90V gr / M00UQU-N/0A/90V gr /90 80 M00UQU-N/A/90V gr /90 80 M00UQU-N/A/90V ar /90 80 M0UQU-N/A/90V 000 8,8 gr / 0 M0UQU-N/A/90V 000 0, gr / 0 M0UQU-N/A/90V , gr / 0 0 M0UQU-N/0A/90V gr / 0 M0UQU-N/A/90V 000 0,8 gr / 0 M0UQU-N/A/90V gr / 0 0 M0UQU-N/0A/90V gr / 0 0 M0UQU-N/0A/90V gr / 0 M0UQU-N/A/90V gr / 0 80 M0UQU-N/80A/90V gr / 0 0 M0UQU-N/0A/90V gr / 0 M0UQU-N/A/90V gr / 0 M0UQU-N/A/90V ar / 0 M00 UQU-N/A/90V Size A B C D E F L N 00C , , , For more information visit: products/semiconductor protection
16 SYSTEM NV-NH NV/NH SERIES TYPES RATED VOLTAGE ar/gr UQ0 M ~ 00V ~90V RATED VOLTAGE Technical data on page Technical data: Standards: IEC 09- Breaking capacity: ~0kA/ ka Rated voltage: ~90V/ 0V Application: Fuse-links type M are applied in fuse base (for example) PK. MUQU-N/80A/90V Size Type (visual indicator with grip for microswitch NVS ) I t-value (A s) Power dissipation (W) Packaging (pcs) Weight (g) In (A) Code No. Char. MUQU-N/A/90V gr / 0 0 MUQU-N/0A/90V gr / 0 MUQU-N/A/90V gr / 0 80 MUQU-N/80A/90V gr / 0 0 MUQU-N/0A/90V gr / 0 MUQU-N/A/90V gr / 0 MUQU-N/A/90V ar / 0 00 MUQU-N/00A/90V ar / 0 MUQU-N/A/90V ar / 0 0 MUQU-N/0A/90V ar / 0 80 MUQU-N/80A/90V gr / 80 0 MUQU-N/0A/90V gr / 80 MUQU-N/A/90V gr / 80 MUQU-N/A/90V ar / MUQU-N/00A/90V ar / 80 0 MUQU-N/0A/90V ar / MUQU-N/80A/90V ar / MUQU-N/00A/90V ar / 80 MUQU-N/A/90V ar / 80 MUQU-N/A/90V ar / MUQU-N/00A/90V ar / 80 0 MUQU-N/0A/90V ar / MUQU-N/80A/90V ar / 880 MUQU-N/A/90V ar / 880 MUQU-N/A/90V ar / MUQU-N/00A/90V ar / MUQU-N/0A/90V ar / MUQU-N/00A/90V ar / MUQU-N/0A/90V ar / MUQU-N/0A/90V ar / 880 Dimensions: For more information visit: products/semiconductor protection Size A B C D E F G H I , , , 9
17 Technical data on page TYPES SERIES TYPES RATED VOLTAGE RATED VOLTAGE ar/gr S80mm/97mm UQ0 M ~90V ~ 00V SYSTEM NV/NH NV-NH Technical data: Standards: IEC 09- Breaking capacity: ~0kA / ka Rated voltage: ~90V / 0V Application: Fuse-links type S of size 00C, 00 and 0 are applied in fuse base US00-/80 and mounted by screws to busbars. Size 00C 00 0 Type (visual indicator with grip for microswitch NVS ) I t-value (A s) Power dissipation (W) Packaging (pcs) Weight (g) In (A) Code No. Char. S00CUQU/80/A/90V 000 9,8 ar / 80 S00CUQU/80/A/90V 000, ar / 80 S00CUQU/80/A/90V 000, ar / 80 0 S00CUQU/80/0A/90V ar / 80 S00CUQU/80/A/90V ,8 ar / 80 S00CUQU/80/A/90V ar / 80 0 S00CUQU/80/0A/90V ar / 80 0 S00CUQU/80/0A/90V ar / 80 S00CUQU/80/A/90V ar / S00CUQU/80/80A/90V 00.0 ar / 80 0 S00CUQU/80/0A/90V ar / 80 S00CUQU/80/A/90V ar / 80 S00UQU/80/A/90V 00 8,8 gr /90 80 S00UQU/80/A/90V 00 0, gr /90 80 S00UQU/80/A/90V 00 70, gr / S00UQU/80/0A/90V 00 0 gr /90 80 S00UQU/80/A/90V 00 0,8 gr /90 80 S00UQU/80/A/90V gr / S00UQU/80/0A/90V gr / S00UQU/80/0A/90V gr /90 80 S00UQU/80/A/90V gr / S00UQU/80/80A/90V gr / S00UQU/80/0A/90V gr /90 80 S00UQU/80/A/90V gr /90 80 S00UQU/80/A/90V ar /90 80 S0UQU/97/A/90V 00 8,8 gr / 0 S0UQU/97/A/90V 00 0, gr / 0 S0UQU/97/A/90V 00 70, gr / 0 0 S0UQU/97/0A/90V 00 0 gr / 0 S0UQU/97/A/90V 00 0,8 gr / 0 S0UQU/97/A/90V gr / 0 0 S0UQU/97/0A/90V gr / 0 0 S0UQU/97/0A/90V gr / 0 S0UQU/97/A/90V gr / 0 80 S0UQU/97/80A/90V gr / 0 0 S0UQU/97/0A/90V gr / 0 S0UQU/97/A/90V gr / 0 S0UQU/97/A/90V ar / 0 S00UQU/80/A/90V Dimensions: Size A D E F I J N 00C 8 8 8, , , 97 9 For more information visit: products/semiconductor protection
18 SYSTEM NV-NH NV/NH SERIES TYPES TYPES RATED VOLTAGE ar/gr UQ0 M Smm ~ 00V ~90V RATED VOLTAGE Technical data on page Technical data: Standards: IEC 09- Breaking capacity: ~0kA / ka Rated voltage: ~90V / 0V Application: Fuse-links type S mm of size,, are applied in universal fuse base US..-/80- and mounted by screws to busbars. SUQU//80A/90V Dimensions: Size Type (visual indicator with grip for microswitch NVS ) I t-value (A s) Power dissipation (W) Packaging (pcs) In (A) Code No. Char. Weight (g) SUQU//A/90V gr / 0 0 SUQU//0A/90V gr / 0 SUQU//A/90V gr / 0 80 SUQU//80A/90V gr / 0 0 SUQU//0A/90V gr / 0 SUQU//A/90V gr / 0 SUQU//A/90V ar / 0 00 SUQU//00A/90V ar / 0 SUQU//A/90V ar / 0 0 SUQU//0A/90V ar / 0 80 SUQU//80A/90V gr / 80 0 SUQU//0A/90V gr / 80 SUQU//A/90V gr / 80 SUQU//A/90V ar / SUQU//00A/90V ar / 80 0 SUQU//0A/90V ar / SUQU//80A/90V ar / SUQU//00A/90V ar / 80 SUQU//A/90V ar / 80 SUQU//A/90V ar / SUQU//00A/90V ar / 80 0 SUQU//0A/90V ar / SUQU//80A/90V ar / 880 SUQU//A/90V ar / 880 SUQU//A/90V ar / SUQU//00A/90V ar / SUQU//0A/90V ar / SUQU//00A/90V ar / SUQU//0A/90V ar / SUQU//0A/90V ar / 880 Not possible for mounting NVS for size. Size A B D E F I J L N 7,, ,, ,, 7 For more information visit: products/semiconductor protection
19 Technical data on page TYPES SERIES TYPES RATED VOLTAGE RATED VOLTAGE ar UQ0 M M ~90V ~ 00V SYSTEM NV/NH NV-NH Technical data: Standards: IEC 09- Breaking capacity: ~00kA Rated voltage: ~90V Application: Fuse-links type M are applied in fuse base (for example PK). M00UQ0/A/90V Size 00 Type (visual indicator with grip for microswitch NVS ) I t-value (A s) Power dissipation (W) Packaging (pcs) In (A) Code No. Char. Weight (g) M00UQ0/A/90V 007 ar /7 M00UQ0/A/90V 007 ar /7 0 M00UQ0/0A/90V ar /7 M00UQ0/A/90V 0077 ar /7 M00UQ0/A/90V ar /7 M00UQ0/A/90V ar /7 0 M00UQ0/0A/90V ar /7 0 M00UQ0/0A/90V ar /7 M00UQ0/A/90V , ar /7 80 M00UQ0/80A/90V , ar /7 0 M00UQ0/0A/90V ar /7 M00UQ0/A/90V ,9 ar /7 M00UQ0/A/90V , ar /7 00* M00UQ0/00A/90V ar /7 0* M00UQ0/0A/90V ar /7 M00UQ0/A/90V ar /7 *Technical data on page 79. Dimensions: Size A B C D E F L N remember Motor drives: Servo drive Servo drive for AC servo motor (CNC machine) For more information visit: products/semiconductor protection
20 SYSTEM NV-NH NV/NH SERIES TYPES TYPES ar RATED VOLTAGE UQ0 M M ~ 00V ~90V RATED VOLTAGE Technical data on page 80 Technical data: Standards: IEC 09- Breaking capacity: ~00kA Rated voltage: ~90V Application: Fuse-link type M are applied in fuse base PK MUQ0/A/90V Size Type (visual indicator ) I t-value (A s) Power dissipation (W) Packaging (pcs.) In (A) Code No. Char. Weight (g) MUQ0/A/90V ar / MUQ0/80A/90V ar / 00 0 MUQ0/0A/90V ar / 00 MUQ0/A/90V ar / 00 MUQ0/A/90V ar / MUQ0/00A/90V ar / 00 0 MUQ0/0A/90V ar / 00 MUQ0/A/90V ar / 00 0 MUQ0/0A/90V ar / MUQ0/00A/90V ar / 00 0 MUQ0/0A/90V ar / 0 MUQ0/A/90V ar / 0 0 MUQ0/0A/90V ar / 0 00 MUQ0/00A/90V ar / 0 0 MUQ0/0A/90V ar / 0 00 MUQ0/00A/90V ar / 0 0 MUQ0/0A/90V ar / 0 0 MUQ0/0A/90V ar / 0 00 MUQ0/00A/90V ar / 80 0 MUQ0/0A/90V ar / MUQ0/00A/90V ar / 80 0 MUQ0/0A/90V ar / 80 7 MUQ0/7A/90V ar / MUQ0/800A/90V ar / MUQ0/900A/90V ar / MUQ0/00A/90V ar / 80 Dimensions: 9,8 E B F C D L N A Size A B C D E F L N For more information visit: products/semiconductor protection
21 Technical data on page TYPES SERIES TYPES RATED VOLTAGE RATED VOLTAGE ar S80mm UQ0 M ~90V ~ 00V SYSTEM NV/NH NV-NH Technical data: Standards: IEC 09- Breaking capacity: ~00kA Rated voltage: ~90V Application: Fuse-links type S of size 00C and 00 are applied in fuse base US00-/80 and mounted by screws to busbars. S00UQ0/80/0A/90V Size 00C 00 Type (visual indicator with grip for microswitch NVS ) I t-value (A s) Power dissipation (W) Char. Packaging (pcs) Weight (g) In (A) Code No. S00CUQ0/80/A/90V 007 ar / 0 S00CUQ0/80/A/90V 007 ar / 0 0 S00CUQ0/80/0A/90V ar / 0 S00CUQ0/80/A/90V 0077 ar / 0 S00CUQ0/80/A/90V ar / 0 S00CUQ0/80/A/90V ar / 0 0 S00CUQ0/80/0A/90V ar / 0 0 S00CUQ0/80/0A/90V ar / 0 S00CUQ0/80/A/90V , ar / 0 80 S00CUQ0/80/80A/90V , ar / 0 0 S00CUQ0/80/0A/90V ar / 0 S00CUQ0/80/A/90V ,9 ar / 0 S00CUQ0/80/A/90V , ar / 0 00 S00CUQ0/80/00A/90V ,7 ar / 0 0 S00CUQ0/80/0A/90V ,8 ar / 0 S00CUQ0/80/A/90V ar / 0 0 S00UQ0/80/0A/90V ar / 0 00 S00UQ0/80/00A/90V ar / 0 Dimensions: I I 9,8 D N J A E Size A D E I J N 00C 0 8, , 78 remember»only fuses for semiconductor protection give us reliable protection for motor drives«said designer with more than 0 years work experience! For more information visit: products/semiconductor protection 7
22 SYSTEM NV-NH NV/NH ar SERIES TYPES TYPES RATED VOLTAGE UQ0 M S80mm ~ 00V ~90V RATED VOLTAGE Technical data: Application: Standards: IEC 09- Breaking capacity: ~00kA Rated voltage: ~90V Fuse-links type S 80mm of size,, are applied in universal fuse base US..-/80- and mounted by screws to busbars. SMUQ0/80/0A/90V Dimensions: Size Type with visual indicator I t-value (A s) Power dissipation (W) Type with centre trip indicator for microswitch MK Code No. Char. In (A) Code No. 80 SUQ0/80/80A/90V , SMUQ0/80/80A/90V 0087 ar / 00 0 SUQ0/80/0A/90V SMUQ0/80/0A/90V 0087 ar / 00 SUQ0/80/A/90V SMUQ0/80/A/90V 0087 ar / 00 SUQ0/80/A/90V , SMUQ0/80/A/90V 0087 ar / SUQ0/80/00A/90V , SMUQ0/80/00A/90V ar / 00 0 SUQ0/80/0A/90V , SMUQ0/80/0A/90V ar / 00 SUQ0/80/A/90V SMUQ0/80/A/90V 0087 ar / 00 0 SUQ0/80/0A/90V SMUQ0/80/0A/90V 0087 ar / SUQ0/80/00A/90V SMUQ0/80/00A/90V 0087 ar / 00 0 SUQ0/80/0A/90V SMUQ0/80/0A/90V 0087 ar / SUQ0/80/00A/90V SMUQ0/80/00A/90V 0087 ar / 00 0 SUQ0/80/0A/90V SMUQ0/80/0A/90V ar / 00 0 SUQ0/80/0A/90V SMUQ0/80/0A/90V ar / 00 7* SUQ0/80/7A/90V SMUQ0/80/7A/90V 0077 ar / SUQ0/80/00A/90V SMUQ0/80/00A/90V 0087 ar / 0 0 SUQ0/80/0A/90V SMUQ0/80/0A/90V 0087 ar / 0 00 SUQ0/80/00A/90V SMUQ0/80/00A/90V 0087 ar / 0 0 SUQ0/80/0A/90V SMUQ0/80/0A/90V ar / 0 0 SUQ0/80/0A/90V SMUQ0/80/0A/90V ar / 0 7 SUQ0/80/7A/90V SMUQ0/80/7A/90V ar / SUQ0/80/800A/90V SMUQ0/80/800A/90V ar / 0 900* SUQ0/80/900A/90V SMUQ0/80/900A/90V 0077 ar / 0 00* SUQ0/80/00A/90V SMUQ0/80/00A/90V 0077 ar / 0 0 SUQ0/80/0A/90V SMUQ0/80/0A/90V ar / 80 7 SUQ0/80/7A/90V SMUQ0/80/7A/90V ar / SUQ0/80/800A/90V SMUQ0/80/800A/90V ar / SUQ0/80/900A/90V SMUQ0/80/900A/90V 0087 ar / SUQ0/80/00A/90V SMUQ0/80/00A/90V 0087 ar / 80 0 SUQ0/80/0A/90V SMUQ0/80/0A/90V 0087 ar / 80 0 SUQ0/80/0A/90V SMUQ0/80/0A/90V 0087 ar / 80 0* SUQ0/80/0A/90V SMUQ0/80/0A/90V 0077 ar / 80 Pack. (pcs) Weight (g) E B I Technical data on page SUQ0/80/0A/90V *Technical data on page 80. I D N J A Size A B D E F F I J N For more information visit: products/semiconductor protection 8
23 TYPES SERIES TYPES RATED VOLTAGE RATED VOLTAGE ar Smm UQ0 M ~90V ~ 00V SYSTEM NV/NH NV-NH Technical data: Standards: IEC 09- Breaking capacity: ~00kA Rated voltage: ~90V Application: Fuse-links type S mm of size,, are applied in universal fuse base US..-/80- and mounted by screws to busbars. Size Type with visual indicator I t-value (A s) Power dissipation (W) Type with centre trip indicator for microswitch MK Code No. Char. In (A) Code No. 80 SUQ0//80A/90V , SMUQ0//80A/90V 0097 ar / 00 0 SUQ0//0A/90V SMUQ0//0A/90V 0097 ar / 00 SUQ0//A/90V SMUQ0//A/90V 0097 ar / 00 SUQ0//A/90V , SMUQ0//A/90V 0097 ar / SUQ0//00A/90V , SMUQ0//00A/90V ar / 00 0 SUQ0//0A/90V , SMUQ0//0A/90V ar / 00 SUQ0//A/90V SMUQ0//A/90V 0097 ar / 00 0 SUQ0//0A/90V SMUQ0//0A/90V 0097 ar / SUQ0//00A/90V SMUQ0//00A/90V 0097 ar / 00 0 SUQ0//0A/90V SMUQ0//0A/90V 0097 ar / SUQ0//00A/90V SMUQ0//00A/90V 0097 ar / 00 0 SUQ0//0A/90V SMUQ0//0A/90V ar / 00 0 SUQ0//0A/90V SMUQ0//0A/90V ar / 00 7* SUQ0//7A/90V SMUQ0//7A/90V ar / SUQ0//00A/90V SMUQ0//00A/90V 0097 ar / 0 0 SUQ0//0A/90V SMUQ0//0A/90V 0097 ar / 0 00 SUQ0//00A/90V SMUQ0//00A/90V 0097 ar / 0 0 SUQ0//0A/90V SMUQ0//0A/90V ar / 0 0 SUQ0//0A/90V SMUQ0//0A/90V ar / 0 7 SUQ0//7A/90V SMUQ0//7A/90V ar / SUQ0//800A/90V SMUQ0//800A/90V ar / 0 900* SUQ0//900A/90V SMUQ0//900A/90V 0077 ar / 0 00* SUQ0//00A/90V SMUQ0//00A/90V 0077 ar / 0 0 SUQ0//0A/90V SMUQ0//0A/90V ar / 80 7 SUQ0//7A/90V SMUQ0//7A/90V ar / SUQ0//800A/90V SMUQ0//800A/90V ar / SUQ0//900A/90V SMUQ0//900A/90V 0097 ar / SUQ0//00A/90V SMUQ0//00A/90V 0097 ar / 80 0 SUQ0//0A/90V SMUQ0//0A/90V 0097 ar / 80 0 SUQ0//0A/90V SMUQ0//0A/90V 0097 ar / 80 0* SUQ0//0A/90V SMUQ0//0A/90V 0077 ar / 80 Pack. (pcs) Weight (g) SUQ0//0A/90V SMUQ0//0A/90V Dimensions: E B I Technical data on page *Technical data on page 80. I D N J A Size A B D E F F I J N For more information visit: products/semiconductor protection 9
24 SYSTEM NV-NH NV/NH SERIES TYPES TYPES ar RATED VOLTAGE UQ0 M G ~ 00V ~90V RATED VOLTAGE Technical data on page Technical data: Standards: IEC 09- Breaking capacity: ~00kA Rated voltage: ~90V Application: Fuse-links type G has threaded studs so fuses are mounted by special screws to busbars. GUQ0/0A/90V GMUQ0/0A/90V Size Type with visual indicator I t-value (A s) Power dissipation (W) Type with centre trip indicator for microswitch MK Code No. Char. In (A) Code No. 80 GUQ0/80A/90V , GMUQ0/80A/90V 007 ar / 00 0 GUQ0/0A/90V GMUQ0/0A/90V 007 ar / 00 GUQ0/A/90V GMUQ0/A/90V 007 ar / 00 GUQ0/A/90V , GMUQ0/A/90V 007 ar / GUQ0/00A/90V , GMUQ0/00A/90V 0077 ar / 00 0 GUQ0/0A/90V , GMUQ0/0A/90V 0079 ar / 00 GUQ0/A/90V GMUQ0/A/90V 007 ar / 00 0 GUQ0/0A/90V GMUQ0/0A/90V 007 ar / GUQ0/00A/90V GMUQ0/00A/90V 007 ar / 00 0 GUQ0/0A/90V GMUQ0/0A/90V 007 ar / GUQ0/00A/90V GMUQ0/00A/90V 007 ar / 00 0 GUQ0/0A/90V GMUQ0/0A/90V 0077 ar / 00 0 GUQ0/0A/90V GMUQ0/0A/90V 0078 ar / 00 7* GUQ0/7/90V GMUQ0/7A/90V 0079 ar / GUQ0/00A/90V GMUQ0/00A/90V 007 ar / 0 0 GUQ0/0A/90V GMUQ0/0A/90V 007 ar / 0 00 GUQ0/00A/90V GMUQ0/00A/90V 007 ar / 0 0 GUQ0/0A/90V GMUQ0/0A/90V 0077 ar / 0 0 GUQ0/0A/90V GMUQ0/0A/90V 0078 ar / 0 7 GUQ0/7A/90V GMUQ0/7A/90V 0079 ar / GUQ0/800A/90V GMUQ0/800A/90V 0070 ar / 0 900* GUQ0/900A/90V GMUQ0/900A/90V 007 ar / 0 00* GUQ0/00A/90V GMUQ0/00A/90V 007 ar / 0 0 GUQ0/0A/90V GMUQ0/0A/90V 0078 ar / 80 7 GUQ0/7A/90V GMUQ0/7A/90V 0079 ar / GUQ0/800A/90V GMUQ0/800A/90V 0070 ar / GUQ0/900A/90V GMUQ0/900A/90V 007 ar / GUQ0/00A/90V GMUQ0/00A/90V 007 ar / 80 0 GUQ0/0A/90V GMUQ0/0A/90V 007 ar / 80 0* GUQ0/0A/90V GMUQ0/0A/90V 007 ar / 80 0* GUQ0/0A/00V GMUQ0/0A/00V 007 ar / 80 *Technical data on page 80. Pack. (pcs) Weight (g) Dimensions: 0 Size D E F F M N 90 M M M For more information visit: products/semiconductor protection
25 Technical data on page 0 TYPES SERIES TYPES RATED VOLTAGE RATED VOLTAGE ar M UQ0 M ~00V ~ 00V SYSTEM NV/NH NV-NH Technical data: Standards: IEC 09- Breaking capacity: ~00kA Rated voltage: ~00V Application: Fuse-links type M are applied in fuse base (for example PK). M0UQ/0A/00V Size 0 Type (visual indicator with grip for microswitch NVS ) I t-value (A s) Power dissipation (W) Packaging (pcs) Weight (g) In (A) Code No. Char. M0UQ/A/00V ar / 0 0 M0UQ/0A/00V ar / 0 M0UQ/A/00V ar / 0 M0UQ/A/00V , ar / 0 0 M0UQ/0A/00V 00 80, ar / 0 0 M0UQ/0A/00V , ar / 0 M0UQ/A/00V 00.0, ar / 0 80 M0UQ/80A/00V ,8 ar / 0 0 M0UQ/0A/00V , ar / 0 M0UQ/A/00V , ar / 0 M0UQ/A/00V , ar / 0 Dimensions: Size A B C D E F L N , 7 remember Motor drives: Frequency inverter Frequency inverter for phase AC motor (lift-elevator) For more information visit: products/semiconductor protection
26 SYSTEM NV-NH NV/NH SERIES TYPES TYPES RATED VOLTAGE RATED VOLTAGE ar UQ0 M M ~ 00V ~0V Technical data on page Technical data: Application: MUQ/0A/0V Standards: IEC 09- Breaking capacity: ~00kA Rated voltage: ~0V Fuse-links type M are applied in fuse base (for example U, U, U). Size Type (visual indicator with a grip for microswitch NVS ) I t-value (A s) Power dissipation (W) Packaging (pcs) In (A) Code No. Char. 80 MUQ/80A/0V ar / MUQ/0A/0V ,9 ar / 700 MUQ/A/0V ar / 700 MUQ/A/0V ar / MUQ/00A/0V ar / 700 MUQ/A/0V ar / MUQ/0A/0V ar / 700 MUQ/A/0V ar / 0 0 MUQ/0A/0V ar / 0 00 MUQ/00A/0V ar / 0 MUQ/A/0V ar / 0 00 MUQ/00A/0V ar / 0 0 MUQ/0A/0V ar / 0 Weight (g) Dimensions: remember Size A B C D E L N 9 0/* 0, 09 /0* /7* 0 8 * The width of the knife is grated in dependence of rating. For the protection of drives most manufacturers seem to have accepted that circuit breakers despite many advantages are not an option for protection drives. The operational characteristics for circuit breakers are simply to slow, allowing too much energy to pass through. Energy let-through Circuit breaker Fuse for semiconductor protection For more information visit: products/semiconductor protection
27 Technical data on page TYPES SERIES TYPES RATED VOLTAGE RATED VOLTAGE ar S80mm UQ0 M ~00V ~ 00V SYSTEM NV/NH NV-NH Technical data: Standards: IEC 09- Breaking capacity: ~00kA Rated voltage: ~00V Application: Fuse-links type S of size 00C and 00 are applied in fuse base US00-/80 and mounted by screws to busbars. Size 00 *900V Type (visual indicator with grip for microswitch NVS ) I t-value (A s) Power dissipation (W) Packaging (pcs) In (A) Code No. Char. Weight (g) S00UQ0/80/A/00V ar / 0 S00UQ0/80/A/00V , ar / 0 0 S00UQ0/80/0A/00V , ar / 0 0 S00UQ0/80/0A/00V ar / 0 S00UQ0/80/A/00V , ar / 0 80 S00UQ0/80/80A/00V , ar / 0 0 S00UQ0/80/0A/00V ar / 0 S00UQ0/80/A/00V , ar / 0 S00UQ0/80/A/00V , ar / 0 00 S00UQ0/80/00A/00V ar / 0 0 S00UQ0/80/0A/00V ar / 0 * S00UQ0/80/A/900V ar / 0 S00UQ0/80/00A/00V Dimensions: I I 9,8 D N J A E Size A D E I J N remember Future applications: Protection for alternative energy power plant: - Wind power - Solar power - Fuel cell For more information visit: products/semiconductor protection
28 SYSTEM NV-NH NV/NH SERIES TYPES TYPES RATED VOLTAGE RATED VOLTAGE ar UQ0 M S-M ~ 00V ~00V Technical data on page 0 Technical data: Application: S0/8/A/00V M Standards: IEC 09- Breaking capacity: ~00kA Rated voltage: ~00V Fuse-links type S0 M are mounted by screws to busbars. I t-value (A s) Power dissipation (W) Packaging (pcs) Size In (A) Type (visual indicator) Code No. Char. S0/8/A/00V M ar / 0 0 S0/8/0A/00V M ar / 0 S0/8/A/00V M ar / 0 S0/8/A/00V M , ar / 0 0 S0/8/0A/00V M 00 80, ar / S0/8/0A/00V M , ar / 0 S0/8/A/00V M 00.0, ar / 0 80 S0/8/80A/00V M ar / 0 0 S0/8/0A/00V M , ar / 0 S0/8/A/00V M , ar / 0 S0/8/A/00V M , ar / 0 Weight (g) Dimensions:,00,0 8,00 0,00 8,00,0 0,00 7,00,00 For more information visit: products/semiconductor protection
29 TYPES SERIES TYPES RATED VOLTAGE RATED VOLTAGE ar Smm UQ0 M ~00V ~ 00V SYSTEM NV/NH NV-NH Technical data: Standards: IEC 09- Breaking capacity: ~00kA Rated voltage: ~00V Application: Fuse-links type S mm of size,, are applied in universal fuse base US..-/80- and mounted by screws to busbars. SUQ0//00A/00V Size Type with visual indicator I t-value (A s) Power dissipation (W) Type with centre trip indicator for microswitch MK Code No. Char. In (A) Code No. SUQ0//A/00V , SMUQ0//A/00V 0007 ar / SUQ0//80A/00V SMUQ0//80A/00V 0007 ar / 00 0 SUQ0//0A/00V SMUQ0//0A/00V 0007 ar / 00 SUQ0//A/00V SMUQ0//A/00V 0007 ar / 00 SUQ0//A/00V SMUQ0//A/00V 0007 ar / SUQ0//00A/00V , SMUQ0//00A/00V ar / 00 0 SUQ0//0A/00V SMUQ0//0A/00V ar / 00 SUQ0//A/00V SMUQ0//A/00V 0007 ar / 00 0 SUQ0//0A/00V SMUQ0//0A/00V 0007 ar / SUQ0//00A/00V SMUQ0//00A/00V 0007 ar / 00 0 SUQ0//0A/00V SMUQ0//0A/00V 0007 ar / SUQ0//00A/00V SMUQ0//00A/00V 0007 ar / 00 SUQ0//A/00V SMUQ0//A/00V 0007 ar / 0 0 SUQ0//0A/00V SMUQ0//0A/00V 0007 ar / 0 00 SUQ0//00A/00V SMUQ0//00A/00V 0007 ar / 0 0 SUQ0//0A/00V SMUQ0//0A/00V 0007 ar / 0 00 SUQ0//00A/00V SMUQ0//00A/00V 0007 ar / 0 0 SUQ0//0A/00V SMUQ0//0A/00V ar / 0 0 SUQ0//0A/00V SMUQ0//0A/00V ar / 0 00 SUQ0//00A/00V SMUQ0//00A/00V 0007 ar / 80 0 SUQ0//0A/00V SMUQ0//0A/00V ar / 80 7 SUQ0//7A/00V SMUQ0//7A/00V ar / SUQ0//800A/00V SMUQ0//800A/00V ar / SUQ0//00A/00V SMUQ0//00A/00V 0007 ar / 80 0 SUQ0//0A/00V SMUQ0//0A/00V 0007 ar / 80 Pack. (pcs) Weight (g) SMUQ0//00A/00V Dimensions: E B I Technical data on page I D N J A Size A B D E F F I J N For more information visit: products/semiconductor protection
30 SYSTEM NV-NH NV/NH SERIES TYPES RATED VOLTAGE RATED VOLTAGE ar UQ0 M G ~ 00V ~00V Technical data on page Technical data: Standards: IEC 09- Breaking capacity: ~00kA Rated voltage: ~00V Application: Fuse-links type G has threaded studs so fuses are mounted by special screws to busbars. GUQ0/800A/00V GMUQ0/00A/00V Size Type with visual indicator I t-value (A s) Power dissipa tion (W) Type with centre trip indicator for microswitch MK Code No. Char. In (A) Code No. GUQ0/A/00V , GMUQ0/A/00V 000 ar / GUQ0/80A/00V GMUQ0/80A/00V 000 ar / 00 0 GUQ0/0A/00V GMUQ0/0A/00V 000 ar / 00 GUQ0/A/00V GMUQ0/A/00V 000 ar / 00 GUQ0/A/00V GMUQ0/A/00V 000 ar / GUQ0/00A/00V , GMUQ0/00A/00V 0007 ar / 00 0 GUQ0/0A/00V GMUQ0/0A/00V 0009 ar / 00 GUQ0/A/00V GMUQ0/A/00V 000 ar / 00 0 GUQ0/0A/00V GMUQ0/0A/00V 000 ar / GUQ0/00A/00V GMUQ0/00A/00V 000 ar / 00 0 GUQ0/0A/00V GMUQ0/0A/00V 000 ar / GUQ0/00A/00V GMUQ0/00A/00V 000 ar / 00 GUQ0/A/00V GMUQ0/A/00V 000 ar / 0 0 GUQ0/0A/00V GMUQ0/0A/00V 000 ar / 0 00 GUQ0/00A/00V GMUQ0/00A/00V 000 ar / 0 0 GUQ0/0A/00V GMUQ0/0A/00V 000 ar / 0 00 GUQ0/00A/00V GMUQ0/00A/00V 000 ar / 0 0 GUQ0/0A/00V GMUQ0/0A/00V 0007 ar / 0 0 GUQ0/0A/00V GMUQ0/0A/00V 0008 ar / 0 00 GUQ0/00A/00V GMUQ0/00A/00V 000 ar / GUQ0/0A/00V GMUQ0/0A/00V 0008 ar / GUQ0/7A/00V GMUQ0/7A/00V 0009 ar / GUQ0/800A/00V GMUQ0/800A/00V 0000 ar / GUQ0/00A/00V GMUQ0/00A/00V 000 ar / GUQ0/0A/00V GMUQ0/0A/00V 000 ar / GUQ0/0A/00V GMUQ0/0A/00V 000 ar /8 80 Pack. (pcs) Weight (g) Dimensions: Size D E F F M N 90 M M M 7 For more information visit: products/semiconductor protection
31 Technical data on page 7 TYPES SERIES TYPES RATED VOLTAGE RATED VOLTAGE ar S UQ0 M ~0V ~ 00V SYSTEM NV/NH NV-NH Technical data: Standards: IEC 09- Breaking capacity: ~0kA Rated voltage: ~0V Application: Protection of semiconductors inside middle voltage inverters. SMUQ0//00A/0V Size I t-value at 00V (A s) I t-value at 0V (A s) Power dissipation (W) Type with centre trip indicator for Pre-arcing I t- In (A) microswitch MK Code No. value (A s) Char. 0 SMUQ0//0A/0V ar 0 SMUQ0//0A/0V ar 00 SMUQ0//00A/0V ar 0 SMUQ0//0A/0V ar 0 SMUQ0//0A/0V ar 7 SMUQ0//7A/0V ar 0 SMUQ0//0A/0V ar 0 SMUQ0//0A/0V ar 0 SMUQ0//0A/0V ar 00 SMUQ0//00A/0V ar Pack. (pcs) Weight (g) Dimensions: H B H E 8 Size B E H H For more information visit: products/semiconductor protection 7
32 SYSTEM NV-NH NV/NH SERIES TYPES TYPES RATED VOLTAGE RATED VOLTAGE ar UQ0 M G ~ 00V ~0V Technical data on page 7 Technical data: Standards: IEC 09- Breaking capacity: ~0kA Rated voltage: ~0V Application: Protection of semiconductors inside middle voltage inverters. Size Pre-arcing I t-value (A s) I t-value at 00V (A s) I t-value at 0V (A s) Power dissipation (W) Type with centre trip indicator In (A) for microswitch MK Code No. Char. GMUQ0/A/0V ar 00 GMUQ0/00A/0V ar 7 GMUQ0/7A/0V ar 0 GMUQ0/0A/0V ar 7 GMUQ0/7A/0V ar 800 GMUQ0/800A/0V ar 900 GMUQ0/900A/0V ar 00 GMUQ0/00A/0V ar Packaging (pcs) Weight (g) 00 Dimensions: GMUQ0/00A/0V 80 M 7 8 For more information visit: products/semiconductor protection 8
33 Technical data on page 7 TYPES SERIES TYPES RATED VOLTAGE RATED VOLTAGE ar S UQ0 M ~00V ~ 00V SYSTEM NV/NH NV-NH Technical data: Standards: IEC 09- Breaking capacity: ~0kA Rated voltage: ~00V Application: Protection of semiconductors inside middle voltage inverters. SMUQ0//0A/00V Size I t-value at 00V (A s) Power dissipation (W) Type with centre trip indicator for In (A) microswitch MK Code No. Char. 0 SMUQ0//0A/00V ar SMUQ0//A/00V ar 00 SMUQ0//00A/00V ar 0 SMUQ0//0A/00V ar 0 SMUQ0//0A/00V ar Pack. (pcs) Weight (g) 00 Dimensions: For more information visit: products/semiconductor protection 9
34 SYSTEM NV-NH NV/NH SERIES TYPES TYPES RATED VOLTAGE RATED VOLTAGE ar UQ0 M G ~ 00V ~00V Technical data on page 7 Technical data: Standards: IEC 09- Breaking capacity: ~0kA Rated voltage: ~00V Application: Protection of semiconductors inside middle voltage inverters. Size Type with centre trip indicator for microswitch MK I t- value at 00V (A s) Power dissipation (W) Packaging (pcs) Weight (g) In (A) Code No. Char. 00 GMUQ0/00A/00V ar 00 0 GMUQ0/0A/00V ar 00 Dimensions: GMUQ0/0A/00V 99 M 0 For more information visit: products/semiconductor protection 0
35 Technical data on page 7 TYPES SERIES TYPES RATED VOLTAGE RATED VOLTAGE ar S UQ0 M ~000V ~ 00V SYSTEM NV/NH NV-NH Technical data: Standards: IEC 09- Breaking capacity: ~0kA Rated voltage: ~000V Application: Protection of semiconductors inside middle voltage inverters. Size I t- value at 000V (A s) Power dissipation (W) Type with centre trip indicator for Pre-arcing In (A) microswitch MK Code No. I t-value (A s) Char. 0 SUQ/-/0A/000V ar 0 SUQ/-/0A/000V ar 00 SUQ/-/00A/000V ar 0 SUQ/-/0A/000V ar SUQ/-/A/000V ar 0 SUQ/-/0A/000V ar 7 SUQ/-/7A/000V ar Pack. (pcs) Weight (g) 000 SUQ/-/0A/000V Protection of semiconductors inside middle voltage inverters. Dimensions: For more information visit: products/semiconductor protection
36 SYSTEM NV-NH NV/NH SERIES TYPES TYPES gr RATED VOLTAGE UQ0 M M, M-STRIKER PIN ~ 00V ~90V RATED VOLTAGE Technical data on page 9 Technical data: Standards: IEC 09- Breaking capacity: ~00kA Rated voltage: ~90V, 0V Application: For battery protection in UPS systems. Size 00C M00CUQ/A/90V In (A) Type (visual indicator with grip for microswitch NVS ) I t-value (A s) Power dissipation (W) Type with striker pin Code No. Char. Packaging (pcs) Code No. M00CUQ/A/90V 007 0, - - gr / M00CUQ/A/90V M00CUQ/A/90V-K 007 gr / 0 M00CUQ/0A/90V , M00CUQ/0A/90V-K 007 gr / M00CUQ/A/90V ,8 M00CUQ/A/90V-K 007 gr / M00CUQ/A/90V , M00CUQ/A/90V-K 007 gr / M00CUQ/A/90V , M00CUQ/A/90V-K 007 gr / 0 M00CUQ/0A/90V , M00CUQ/0A/90V-K 007 gr / 0 M00CUQ/0A/90V 007.0, M00CUQ/0A/90V-K 007 gr / M00CUQ/A/90V ,8 M00CUQ/A/90V-K 0077 gr / 80 M00CUQ/80A/90V , M00CUQ/80A/90V-K 0078 gr / 0 M00CUQ/0A/90V ,7 M00CUQ/0A/90V-K 0079 gr / M00CUQ/A/90V M00CUQ/A/90V-K 0070 gr / M00CUQ/A/90V ,9 M00CUQ/A/90V-K 007 gr / Dimensions: Weight (g) Size A B C E G S L N P T 00C 78 0, 8 remember In the past, all soft-starters and drives incorporated internal high -speed fusing. As these devices have gotten smaller, cheaper, many manu facturers of medium to low power motor controllers have eliminated internal fusing. Adequate electrical protection is now in hand of designers. For more information visit: products/semiconductor protection
37 Technical data on page 9 TYPES SERIES TYPES RATED VOLTAGE RATED VOLTAGE gr M, M-STRIKER UQ0 PIN M ~90V ~ 00V SYSTEM NV/NH NV-NH Technical data: Standards: IEC 09- Breaking capacity: ~00kA Rated voltage: ~90V, 0V Application: For battery protection in UPS systems. Size In (A) Type (visual indicator with grip for microswitch NVS ) I t-value (A s) Power dissipation (W) Type with striker pin Code No. Char. Packaging (pcs) Code No. MUQ/A/90V , - - gr / 0 0 MUQ/0A/90V , - - gr / 0 0 MUQ/0A/90V 007.0, MUQ/0A/90V-K 0070 gr / 0 MUQ/A/90V ,8 MUQ/A/90V-K 007 gr / 0 80 MUQ/80A/90V , MUQ/80A/90V-K 007 gr / 0 0 MUQ/0A/90V ,7 MUQ/0A/90V-K 007 gr / 0 MUQ/A/90V MUQ/A/90V-K 007 gr / 0 MUQ/A/90V ,9 MUQ/A/90V-K 007 gr / 0 00 MUQ/00A/90V , MUQ/00A/90V-K 007 gr / 0 MUQ/A/90V ,8 MUQ/A/90V-K 0077 gr / 0 0 MUQ/0A/90V ,7 MUQ/0A/90V-K 0078 gr / 0 MUQ/A/90V MUQ/A/90V-K 007 gr / 0 MUQ/A/90V ,9 MUQ/A/90V-K 007 gr / 0 00 MUQ/00A/90V , MUQ/00A/90V-K 007 gr / 0 MUQ/A/90V ,8 MUQ/A/90V-K 007 gr / 0 0 MUQ/0A/90V ,7 MUQ/0A/90V-K 007 gr / 0 MUQ/A/90V MUQ/A/90V-K 007 gr / 0 0 MUQ/0A/90V MUQ/0A/90V-K 0077 gr / 0 00 MUQ/00A/90V MUQ/00A/90V-K 0078 gr / 0 0 MUQ/0A/90V ,7 MUQ/0A/90V-K 007 gr / 870 MUQ/A/90V MUQ/A/90V-K 007 gr / MUQ/0A/90V MUQ/0A/90V-K 007 gr / MUQ/00A/90V MUQ/00A/90V-K 007 gr / 870 MUQ/A/90V MUQ/A/90V-K 007 gr / MUQ/00A/90V MUQ/00A/90V-K 007 gr / MUQ/0A/90V MUQ/0A/90V-K 0077 gr / 870 Weight (g) Dimensions: MUQ/0A/90V Size A B C E G S L N P R T 0 7 0,,7 7, ,, 7, , 7 7, For more information visit: products/semiconductor protection
38 SYSTEM NV-NH NV/NH SERIES TYPES TYPES gr RATED VOLTAGE UQ0 M M, S ~ 00V ~00V RATED VOLTAGE Technical data on page 7 Technical data: Standards: IEC 09- Breaking capacity: ~00kA Rated voltage: ~00V Application: Fuse-links type M are applied in fuse base: -PK for size -HVLa for size a Size a Type (visual indicator with grip for microswitch NVS ) I t-value (A s) Power dissipation (W) Packaging (pcs) Weight (g) In (A) Code No. Char. 800 SUQ/800A/00V gr 0 00 SUQ/00A/00V gr 0 0 SUQ/0A/00V gr MaUQ/800A/00V gr MaUQ/00A/00V gr MaUQ/0A/00V gr MaUQ/00A/00V gr MaUQ/0A/00V gr 700 Dimensions: Size A B C D E F L N M O P R a For more information visit: products/semiconductor protection
39 Technical data on page 9 TYPES SERIES TYPES RATED VOLTAGE RATED VOLTAGE gr S80mm UQ0 M ~90V ~ 00V SYSTEM NV/NH NV-NH Technical data: Standards: IEC 09- Breaking capacity: ~00kA Rated voltage: ~90V, 0V Application: For battery protection in UPS systems. Size 00C Type (visual indicator with grip for microswitch NVS ) I t-value (A s) Power dissipation (W) Packaging (pcs) Weight (g) In (A) Code No. Char. S00CUQ/80/A/90V 007 0, gr / S00CUQ/80/A/90V gr / 0 S00CUQ/80/0A/90V , gr / S00CUQ/80/A/90V ,8 gr / S00CUQ/80/A/90V , gr / S00CUQ/80/A/90V , gr / 0 S00CUQ/80/0A/90V , gr / 0 S00CUQ/80/0A/90V 007.0, gr / S00CUQ/80/A/90V ,8 gr / 80 S00CUQ/80/80A/90V , gr / 0 S00CUQ/80/0A/90V ,7 gr / S00CUQ/80/A/90V gr / S00CUQ/80/A/90V ,9 gr / S00CUQ/80/A/90V Dimensions: I I 9,8 D N J A E Size A D E I J N 00C 0 8, 78 remember One of the fastest growing markets for fuses is protection of semiconductor devices!!! For more information visit: products/semiconductor protection
40 SYSTEM NV-NH NV/NH SERIES TYPES TYPES gr RATED VOLTAGE UQ0 M Smm ~ 00V ~90V RATED VOLTAGE Technical data on page 9 Technical data: Standards: IEC 09- Breaking capacity: ~00kA Rated voltage: ~90V, 0V Application: For battery protection in UPS systems. SUQ//0A/90V Size Type with visual indicator I t-value (A s) Power dissipation (W) Packaging (pcs) Weight (g) In (A) Code No. Char. 80 SUQ//80A/90V , gr / 90 0 SUQ//0A/90V ,7 gr / 90 SUQ//A/90V , gr / 90 SUQ//A/90V ,8 gr / SUQ//00A/90V , gr / 90 SUQ//A/90V ,8 gr / 90 0 SUQ//0A/90V ,7 gr / 90 SUQ//A/90V , gr / SUQ//A/90V ,8 gr / 00 SUQ//00A/90V , gr / SUQ//A/90V ,8 gr / 0 SUQ//0A/90V ,7 gr / SUQ//A/90V gr / 0 SUQ//0A/90V gr / 00 SUQ//00A/90V gr / 0 SUQ//0A/90V ,7 gr / 80 SUQ//A/90V gr / 80 0 SUQ//0A/90V gr / SUQ//00A/90V gr / 80 SUQ//A/90V gr / SUQ//00A/90V gr / 80 0 SUQ//0A/90V gr / 80 Dimensions: G B A C E D Size A B C D E G For more information visit: products/semiconductor protection
41 Technical data on page 7 TYPES SERIES TYPES RATED VOLTAGE RATED VOLTAGE gr G UQ0 M ~00V ~ 00V SYSTEM NV/NH NV-NH Technical data: Standards: IEC 09- Breaking capacity: ~00kA Rated voltage: ~00V Application: Fuse-links type G has threaded studs so fuses are mounted by special screws to busbars. Size Type with visual indicator I t-value (A s) Power dissipation (W) Packaging (pcs) Weight (g) In (A) Code No. Char. GUQ/A/00V gr / 0 0 GUQ/0A/00V , gr / 0 0 GUQ/0A/00V , gr / 0 GUQ/A/00V gr / 0 80 GUQ/80A/00V , gr / 0 0 GUQ/0A/00V , gr / 0 GUQ/A/00V gr / 0 GUQ/A/00V , gr / 0 00 GUQ/00A/00V ,8 gr / 0 GUQ/A/00V , gr / 0 0 GUQ/0A/00V gr / 0 GUQ/A/00V gr / 0 GUQ/A/00V , gr / 0 00 GUQ/00A/00V ,8 gr / 0 GUQ/A/00V , gr / 0 0 GUQ/0A/00V gr / 0 GUQ/A/00V gr / 0 0 GUQ/0A/00V gr / 0 00 GUQ/00A/00V gr / 0 0 GUQ/0A/00V gr / 800 GUQ/A/00V gr / GUQ/0A/00V gr / GUQ/00A/00V gr / 800 GUQ/A/00V gr / GUQ/00A/00V gr / GUQ/0A/00V gr / 800 GUQ/0A/00V Dimensions: Size A B C E G , For more information visit: products/semiconductor protection 7
42 SYSTEM NV/NH TYPES RATED VOLTAGE gs M ~90V Technical data on page 77 Technical data: Application: M00C/A/90V-gS Standards: IEC 09- Breaking capacity: ~0kA Rated voltage: ~90V Special designed for protection of variable speed drive, soft starter, servo drive, DC drive. Dimensions: Size In (A) Type (visual indicator with grip for microswitch NVS ) Code No. I t-value (A s) Power dissipation (W) Char. Packaging (pcs) Weight (g) M00C/A/90V-gS 007,8 gs / 0 M00C/0A/90V-gS 007 0, gs / M00C/A/90V-gS , gs / M00C/A/90V-gS , gs / 0 M00C/0A/90V-gS 007.0,8 gs / 00C 0 M00C/0A/90V-gS , gs / M00C/A/90V-gS , gs / 80 M00C/80A/90V-gS , gs / 0 M00C/0A/90V-gS , gs / 00 M00C/A/90V-gS ,7 gs / M00/A/90V-gS ,0 gs / L 9,8 B E C F N A D Size A B C D E F L N 00C For more information visit: products/semiconductor protection 8
43 Technical data on page 78 TYPES RATED VOLTAGE gs M ~90V SYSTEM NV/NH Technical data: Standards: IEC 09- Breaking capacity: ~0kA Rated voltage: ~90V Application: Special designed for protection of variable speed drive, soft starter, servo drive, DC drive. M/A/90V-gS I t-value (A s) Power dissipation (W) Packaging (pcs) Size In (A) Type (with visual indicator) Code No. Char. Weight (g) M/A/90V-gS gs / 0 00 M/00A/90V-gS gs / 0 0 M/0A/90V-gS gs / 0 M/A/90V-gS gs / 0 0 M/0A/90V-gS gs / 0 00 M/00A/90V-gS gs / 0 0 M/0A/90V-gS gs / 0 00 M/00A/90V-gS gs / 0 0 M/0A/90V-gS gs / M/0A/90V-gS gs / 870 Dimensions: 9,8 E B F C D L N A Size A B C D E F L N For more information visit: products/semiconductor protection 9
44 Technical data: Standards: IEC 09- Breaking capacity: ~0kA Rated voltage: ~90V Application: Special designed for protection of variable speed drive, soft starter, servo drive, DC drive. I t-value (A s) Power dissipation (W) Type with center trip indicator for microswitch MK Code No. Char. Packaging (pcs) Size In (A) Type with visual indicator Code No. S//A/90V-gS SM//A/90V-gS 007 gs / 0 00 S//00A/90V-gS SM//00A/90V-gS 007 gs / 0 0 S//0A/90V-gS SM//0A/90V-gS 0077 gs / 0 S//A/90V-gS SM//A/90V-gS 0078 gs / 0 0 S//0A/90V-gS SM//0A/90V-gS 007 gs / 0 00 S//00A/90V-gS SM//00A/90V-gS 007 gs / 0 0 S//0A/90V-gS SM//0A/90V-gS 0077 gs / 0 00 S//00A/90V-gS SM//00A/90V-gS 0078 gs / 0 0 S//0A/90V-gS SM//0A/90V-gS 007 gs / S//0A/90V-gS SM//0A/90V-gS 007 gs / 870 Weight (g) S//0A/90V-gS Dimensions: E I B I D N J A E F F I SYSTEM NV/NH TYPES RATED VOLTAGE gs S ~90V Technical data on page 78 B I D N J A Size A B D E F F I J N For more information visit: products/semiconductor protection 0
45 Microswitch NVS Technical data: Rated current: ~A Rated voltage: ~V ~0 V SERIES TYPES RATED VOLTAGE UQ0 M ~ 00V Application: Microswitch NVS- is mounted on fuse-links type M. ACCESSORIES SYSTEM NV-NH In (A) Type Code No. Packaging (pcs) Weight (g) NVS /0. Microswitch MK Technical data: Rated current: ~A Rated voltage: ~0 V Application: Microswitch MK is mounted on fuse-links type S-M and G-M. Microswitch MK Adapter AMK for fuses ~ 90V Adapter AMK for fuses ~ 00V Pic.0 Pic.0 Pic.07 In (A) Type Code No. Packaging (pcs) Weight (g) MK / g - AMK / g - AMK / g Microswitch MK + adapter AMK are mounted to the fuse type S-M and G-M/ 90V. Microswitch MK + adapter AMK are mounted to the fuse S-M and G-M/ 00V. remember Today many different types of equipment are already fitted with Variable speed drives. In today s industry avoiding down-time can be the same as creating income. For more information visit: products/semiconductor protection
46 SYSTEM ACCESSORIES NV-NH SERIES TYPES RATED VOLTAGE Fuse base UQ0 US M ~ 00V Technical data: Application: Rated voltage: 00V, 0V US00 Rated current: 00A, 00V US... Rated current: 0A, 0V* *900V when fuse links with 80mm hole centres applied US../0A Rated current: 0A, 0V* *900V when fuse links with 80mm hole centres applied Fuse bases are designed for mounting fuse-links Ultra Quick type S. Type Code No. Packaging (pcs) Weight (g) US00-/ / 8g US...-/ / 90g US..-/80-/0A 00 / 0g Note: Fuse base PK, STV, VLC, PCF, D0, D Catalogue Building and Industry For more information visit: products/semiconductor protection
47 CHARACTERISTICS SERIES TYPES RATED VOLTAGE UQ0 M ~ 00V SYSTEM NV/NH CHARACTERISTICS Characteristics POWER NEEDS CONTROL
48 v CHARACTERISTICS RATED VOLTAGE ~00V SYSTEM D0 Time/current characteristics of fuse-links Ultra Quick D0 and D0 Cut-off characteristics of fuse-links Ultra Quick D0 and D0 t /s A A A A A 0AA A 0AA I p / A Joule Integral (I t) for Ultra Quick D0 and D0 I t c (A s) I / A o I n Power dissipation Pre-arcing Joule integral I t (ms) Joule Integral I t ~0V I K I K Prospective fault current Power dissipation, pre-arcing Joule Integral and Joule Integral for Ultra Quick D0 and D0 Joule Integral I t ~00V Joule Integral I t ~00V A W A s A s A s A s,,,,,7 8,0 7 0, 0, , , , , , I p /A 0 0 I N /A I (A) N U p (V)
49 v SYSTEM D CHARACTERISTICS RATED VOLTAGE ~00V Time/current characteristics of fuse-links Ultra Quick DI, DII, DIII, DIV, DV. Cut-off characteristics of fuse-links Ultra Quick DI, DII, DIII, DIV, DV. t /s A A A 80A 0AA 00A A A 0AA A 0A A I o / A I K I K I /A N - - I p / A Prospective fault current I p /A Joule Integral (I t) for Ultra Quick DI, DII, DIII, DIV, DV I t c (A s) 00 Power dissipation, pre-arcing Joule Integral and Joule Integral for Ultra Quick DI, DII, DIII, DIV, DV. I n Power dissipation Pre-arcing Joule integral I t (ms) Joule Integral I t ~V Joule Integral I t ~0V Joule Integral I t ~00V A W A s A s A s A s, 0,7,8,,8,,8,, 8, 8, 0,, ,, ,0 8, ,0 8 70, , , , , , , , I N (A) U p (V)
50 CHARACTERISTICS SYSTEM NV/NH SERIES TYPES RATED VOLTAGE RATED VOLTAGE UQ0 M ~00/90V ~ 00V CHARACTERISTICS SYSTEM C Time/current characteristics of fuse links Ultra quick CH-size x 8 Time/current characteristics of fuse links Ultra quick CH, CH-S-size x tv/s tv/s Time/current characteristics of fuse links Ultra quick CH, CH-S-size x 8 Ip/A Ip/A tv/s Ip/A
51 CHARACTERISTICS SYSTEM C SERIES RATED VOLTAGE TYPES RATED VOLTAGE UQ0 ~00/90V M ~ 00V SYSTEM CHARACTERISTICS NV/NH Cut-off characteristics of fuse-links Ultra Quick CH size x 8 Io/A A A 0A A A A 8A A In/A Ip/A Cut-off characteristics of fuse-links Ultra Quick CH, CH-S size x Io/A 0A 0A A A 0A A A A In/A Ip/A Cut-off characteristics of fuse-links Ultra Quick CH, CH-S size x 8 Io/A 0A 80A A 0A 0A A A 0A In/A Ip/A 7
52 CHARACTERISTICS SYSTEM NV/NH Conversion factor for total Joule integral SERIES TYPES RATED VOLTAGE RATED VOLTAGE UQ0 M ~00/90V ~ 00V Maximum arc voltage accuring CHARACTERISTICS SYSTEM C, 00,0 CH 00 CH CH, CH, 0, 0, 0, Peak arc voltage (V) , U ef (V) U ef (V ) Correction factor for converting the power dissipation for percentage load Load( %) Correction factor 0,00 0 0,0 0 0, ,0 0 0, 70 0, 80 0, 90 0,78 0 8
53 CHARACTERISTICS SYSTEM C SERIES RATED VOLTAGE TYPES RATED VOLTAGE UQ0 ~00/90V M ~ 00V SYSTEM CHARACTERISTICS NV/NH Power dissipation, pre-arcing Joule integral and Joule integral for Ultra Quick Size CH CH-S CH CH-S CH In Power dissipation Pre-arcing Joule integral I t (ms) Joule Integral I t ~80V Joule Integral I t ~0V Joule Integral I t ~00/90V A W A s A s A s A s, , , 8 0 0, , , , , 0, , , ,
54 CHARACTERISTICS RATED VOLTAGE ~0V SYSTEM BS Time/current characteristics of fuse-links Ultra Quick BS8 Time/current characteristics of fuse-links Ultra Quick BS7 tv/s BS8 A BS8 A BS8A BS8 A BS8 0A Time/current characteristics of fuse-links Ultra Quick BS8 Ip/A Time/current characteristics of fuse-links Ultra Quick BS8T
55 SYSTEM BS CHARACTERISTICS RATED VOLTAGE ~0V Cut-off characteristics of fuse-link Ultra Quick BS8 Cut-off characteristics of fuse-link Ultra Quick BS7 Io/A 0 BS8 0A BS8 A BS8 A BS8 A BS8 A Symetrical fault current Asymetrical fault current 0 Ip/A Prospective fault current Cut-off characteristics of fuse-link Ultra Quick BS8 Cut-off characteristics of fuse-link Ultra Quick BS8T
56 CHARACTERISTICS RATED VOLTAGE ~0V SYSTEM BS Conversion factor for total Joule integral Maximum arc voltage accuring, 00,0 0,8 0, 0, Peak arc votlage (V) , U ef (V ) ) BS8 0 ) BS U ef (V ) ) BS7, 8, 8T ) BS7, 8, 8T Power dissipation, pre-arcing Joule Integral and Joule Integral for Ultra Quick BS8, BS7, BS8, BS8T Size I n Power dissipation BS8 BS7 BS8 BS8T Pre-arcing Joule integral I t (ms) Joule Integral I t ~V Joule Integral I t ~0V A W A s A s A s 9,,8, 7, ,7 8 0, 0, , , , , , , , Correction factor for converting the power dissipation for percentage load Load( %) 0,00 0 0,0 0 0, ,0 0 0, 70 0, 80 0, 90 0,78 0 Correction factor
57 SYSTEM BS CHARACTERISTICS RATED VOLTAGE ~90V Time/current characteristics of fuse-links Ultra Quick BS8 Time/current characteristics of fuse-links Ultra Quick BS7 tv/s 0 BS8 A BS8 A BS8 A BS8 A BS8 0A Time/current characteristics of fuse-links Ultra Quick BS7D Ip/A Time/current characteristics of fuse-links Ultra Quick BS
58 CHARACTERISTICS RATED VOLTAGE ~90V SYSTEM BS Time/current characteristics of fuse-links Ultra Quick BS8T Cut-off characteristics of fuse-links Ultra Quick BS8 Cut-off characteristics of fuse-links Ultra Quick BS7 Io/A BS8 0A BS8 A BS8 A BS8 A BS8 A BS7 A Ip/A Prospective fault current >
59 SYSTEM BS CHARACTERISTICS RATED VOLTAGE ~90V Cut-off characteristics of fuse-links Ultra Quick BS7D Cut-off characteristics of fuse-links Ultra Quick BS Cut-off characteristics of fuse-links Ultra Quick BS8T
PARENT COMPANY BRANCH OFFICES ASSOCIATED COMPANIES
SUBSIDIARIES ETI GUM d.o.o. Obrezija 5, Izlake, Slovenia Phone: +8 5 57 590 E-mail: etigum@eti.si http://www.etigum.si ETI SVIT d.o.o. Bakovnik a, Kamnik, Slovenia Phone: +8 8 89 E-mail: svit@eti.si ETI
More informationSemi conductor fuses PSC 690 V DIN 43620
Semi conductor fuses PSC 690 V DIN 4620 URD 690 VAC Semiconductor Fuses PSC - URD 690 VAC Ferraz Shawmut PSC-URD 690 VAC fuse-links provide maximum flexibility in equipment design and ultimate protection
More informationNow even more application possibilities In all facets of semiconductor protection
Semiconductor Protection Fuses sitor ENGINEERING s Now even more application possibilities In all facets of semiconductor protection For decades now, SITOR semiconductor protection fuses have been reliably
More informationIssued February DATA SHEET 5SX2 MCB. Based on Siemens Industrial Control Catalog
Issued February 2011 DATA SHEET 5SX2 MCB Based on Siemens Industrial Control Catalog General Data Trip characteristics Tripping characteristics acc. to EN 60 898 Tripping characteristic A, -5 Type A characteristic
More informationProtistor size 22x58 ar 690VAC (IEC) / 700VAC (UL)
690VAC (IEC) / VAC (UL) Protistor size 22x58 ar 690VAC (IEC) / VAC (UL) SEMICONDUCTOR PROTECTION FUSES IEC HIGH-SPEED CYLINDRICAL FUSE-LINKS AC PROTECTION FEATURES & BENEFITS Low l²t for improved semiconductor
More informationProtistor size 14x51 gr 690VAC (IEC) / 700VAC (UL)
690VAC (IEC) / 0VAC (UL) Protistor size 4x gr 690VAC (IEC) / 0VAC (UL) SEMICONDUCTOR PROTECTION FUSES IEC HIGH-SPEED CYLINDRICAL FUSE-LINKS AC PROTECTION FEATURES & BENEFITS IEC standard 60269-4 compliant
More informationMINIATURE CIRCUIT BREAKERS LPN UP TO 63 A (10 ka)
MINIATURE CIRCUIT BREAKERS LPN UP TO 3 A (0 ka) For building, commercial and industrial installations up to 3 A 30/400 V a.c. and 0/440 V d.c. For protection of cables and conductors against overload and
More informationIndustrial fuses NFC-DIN industrial fuselinks gg and am curves from 0.16 to 1250 A
from 0. to 0 A Fuse protection The solution for > Motor protection > Cable and device protection fusib a cat fusib_0_c cat fusib b cat Strong points gg fuse from 0. to A > High level performances > High
More informationProtistor size 2x72 and 2x73 ar 550 to 1250VAC (IEC)
Protistor size 2x72 and 2x73 ar SEMICONDUCTOR PROTECTION FUSES SQUARE BODY HIGH-SPEED FUSE-LINKS AC PROTECTION FEATURES & BENEFITS Multiple body sizes and terminals or blades combination ar Class according
More informationCat. No. 140M-F M-D8E-B
Motor Protection Circuit Breakers Product Selection Motor Protection Circuit Breakers Short Circuit Protection Standard Magnetic Trip ( x I e ) Motor Overload Protection Trip Class 0 0 Rated Operational
More informationMax. Short Circuit Current [ka] Standard Motor Protection High Inrush Motor Protection Motor Circuit Protection 600V C-Frame
! Bulletin 0M Motor Circuit Protectors Type Coordination 00V Current Standard Motor Protection High Inrush Motor Protection Motor Circuit Protection 00V For Use With Contactors Below (or larger) 0M-CE-A
More informationCombined RCD/MCB Devices FRBmM, 1+N-pole
Combined RCD/MCB Devices FRBmM, 1+N-pole SG13711 High-quality residual current device / miniature circuit breaker combination, line voltage-independent Contact position indicator red - green Fault current
More informationSwitches 6/1. 6/4 Introduction. 6/5 5TE8 control switches. 6/7 5TE4 8 pushbuttons. 6/9 5TE8 On/Off switches. 6/11 5TE1 switch disconnectors
6/4 Introduction 6/5 5TE8 control switches 6/7 5TE4 8 pushbuttons 6/9 5TE8 On/Off switches 4 6/11 5TE1 switch disconnectors 6 6/1 Switch to manual? Wherever electrical systems need to be switched on or
More informationRCD Fused Connection Unit Model: RCD10WPV. RCD Double Sockets Models: RCD05WAV, RCD06WPV, RCD07MAV, RCD08MPV. Installation & Operating Instructions
RCD Fused Connection Unit Model: RCD10WPV RCD Double Sockets Models: RCD05WAV, RCD06WPV, RCD07MAV, RCD08MPV Installation & Operating Instructions General The Timeguard range of RCDs provides protection
More informationVital. Safety controller. Approvals: Control of: Features: Entire safety system based on the dynamic safety circuit.
Safety controller Vital Approvals: TÜV Nord Vital 1 TÜV Rheinland Vital and 3 Control of: Entire safety system based on the dynamic safety circuit. Features: Vital is based on a single channel safety concept
More informationFerrule fuse-links 10x38 gg 400 to 690VAC
Ferrule fuse-links x8 gg 400 to 690VAC Ferrule fuse-links x8 gg 400 to 690VAC LOW VOLTAGE IEC FUSES IEC CYLINDRICAL FUSE-LINKS FEATURES & BENEFITS Reduced size Full range protection Visual indication of
More informationOTEC Miniature Circuit Breakers (MCB) OTEC Miniature Circuit Breakers (MCB) OTEC Miniature Circuit Breakers (MCB) Areas of Application
Miniature Circuit Breakers Areas of Application Miniature circuit breakers (MCBs) of the N-System primarily protect cables and conductors against overload and short circuit. Thus, they also protect electrical
More informationSwitch Disconnectors, Main and EMERGENCY-STOP Switches
General data Overview Siemens G 2010 1 2 3 NSE0_01931b 4 5 6 7 1 uxiliary switch (3SB for 3K; 3KX for 3KE) 2 IP20 terminal cover (Operator side) 3 3K switch disconnector 4 rcing contacts (only for 3KE)
More informationThermal-Magnetic Circuit Breaker 2216-S
Thermal-Magnetic Circuit Breaker 226-S Description One and two pole thermal-magnetic circuit breaker in compact design with slide actuator, trip-free mechanism, various trip characteristics and optional
More informationFAZ Supplementary Protectors, FAZ Miniature Circuit Breakers, P2 Disconnect Switches Overview
FAZ Supplementary Protectors, FAZ Miniature Circuit Breakers, P2 Disconnect Switches Overview Supplementary Protectors / Miniature Circuit Breakers Page System overview 10/003 10/001 Supplementary protectors
More informationRiLine Compact The smart power distribution system
RiLine Compact The smart power distribution system 2 Power distribution in a confined space Rittal are the leading suppliers of reliable power distribution and backup systems for controlgear. The new RiLine
More informationMULTI 9 System Catalog UL Recognized NC100H Supplementary Protectors
B Curve NC100H Supplementary Protectors Rating 1P 2P 3P 4P 80 MG27164 MG27175 MG27186 MG27197 MULTI 9 System Catalog UL Recognized NC100H Supplementary Protectors C Curve NC100H Supplementary Protectors
More informationResidual Current Devices FRCdM Type B, B+ and Bfq Digital
Residual Current Devices FRCdM Type B, B+ and Bfq Digital All-current sensitive RCCB for fault or additional protection Digital Features System Monitoring: Preventive information / warning before the RCD
More informationDIN Series MINIATURE CIRCUIT BREAKERS, RESIDUAL CURRENT CIRCUIT BREAKERS. Introducing the DIN Series High-quality, high-performance circuit breakers
DIN Series MINIATURE CIRCUIT BREAKERS, RESIDUAL CURRENT CIRCUIT BREAKERS Introducing the DIN Series High-quality, high-performance circuit breakers Features (1) All models fully comply with IEC regulations
More informationNH fuse-links gg VAC with striker size 0, 1, 2, 3, 4
NH fuse-links gg - 690VAC LOW VOLTAGE IEC FUSES IEC NH FUSE-LINKS FEATURES & BENEFITS Dimensions according to DIN 43 620 Parts 1 to 4 Lead free contact blades 0% cadmium APPLICATIONS gg: General purpose
More informationSafety Systems Safety Integrated
3SE2 / SE3 Molded plastic /metal enclosure with separate actuator Application Safety interlock switches with separate actuator are used where the position of doors, covers or safety screens must be monitored
More informationENERGY /// TE'S CROMPTON INSTRUMENTS TE'S CROMPTON INSTRUMENTS CURRENT TRANSFORMERS
ENERGY /// TE'S CROMPTON INSTRUMENTS TE'S CROMPTON INSTRUMENTS CURRENT TRANSFORMERS 2 ENERGY /// TE'S CROMPTON INSTRUMENTS 3 Table of contents I. Tape Wound Measuring and Protection Current MR Series Measuring
More informationSemiconductor (AC) fuses
Main characteristics 450 TO 700VAC / 63 TO 2800A Recognized Exceptionally low I 2 T, Watt losses. Non-magnetic construction, Highly reliable low voltage Trip-indicator system, conformity to UL, IEC, DIN
More informationMG24434 Supplementary Protector SUPPLEMENTARY PROTECTOR, 240VAC, 16A, CIRCUIT BREAKER TYPE: STANDARD
United States MG24434 Supplementary Protector SUPPLEMENTARY PROTECTOR, 240VAC, 16A, CIRCUIT BREAKER TYPE: STANDARD Product Information Features and Specifications For Use With: OEM Panels Approvals: UL
More information29 $ Manual Motor Starters FREESHIPPING. MOTOR CONTROLS 25. Features: MMS-32H Frame. MMS-63H Frame.
www.factorymation.com/motorcontrols MOTOR CONTROLS 25 Manual Motor Starters High interrupt capacity Din rail and surface mounting Lockable handle (OFF position) IP20 finger safe terminals Class 10 thermal
More informationE-Series General Specifications
-Series General Specifications Ideally suited for higher amperage applications. Available with front and back mounting, screw terminals, stud terminals and heavy duty box wire connectors for solid wire
More informationMicro Contactor MA Series
Relay-sized contactor, making it the world s smallest >3mm contact clearance acc. to IEC 60335-1 for Safety Applications Reversing contactor with mechanical interlock 3 Pole and 1 Aux. Contact NO or NC
More information4. CIRCUIT BREAKERS. Functional Emergency Switching
4. CIRCUIT BREAKERS The circuit breaker/disconnector fulfils all of the basic switchgear functions, while, by means of accessories, numerous other possibilities exist. As shown in table H2-19 the circuit
More informationProtistor size 14x51 gr 690VAC (IEC) / 700VAC (UL)
690VAC (IEC) / VAC (UL) Protistor size 4x5 gr 690VAC (IEC) / VAC (UL) SEMICONDUCTOR PROTECTION FUSES IEC HIGH-SPEED CYLINDRICAL FUSE-LINKS AC PROTECTION FEATURES & BENEFITS IEC standard 60269-4 compliant
More informationSafe timer relay/contact expansion modules
Contact expander module for increasing the number of available contacts, Pulse-on timer relay for step-by-step control of movement sequences, Delay-on energisation timer for unlocking an interlock with
More informationSafe monitoring relays
monitor for safe standstill monitoring Approvals Block diagram Unit features Positive-guided relay outputs: 2 safety contacts (N/O), instantaneous 1 auxiliary contact (N/C), instantaneous LED indicator
More informationEx magnetic safety sensors, cylindrical form // Series EEx RC Si M30
Ex magnetic safety sensors, cylindrical form // Series EEx RC Si M30 - Ex zone 1 and 2, as well as 21 and 22 - Metal enclosure - Available in stainless steel enclosure - Reed contacts, coded - Actuation
More informationThermal-Magnetic Circuit Breaker 4220-T...
Thermal-Magnetic Circuit Breaker 40-T... Description Single, double and three pole thermal-magnetic circuit breakers with high rupture capacity to UL 489 (5 ka), EN/IEC 60934 (6kA) and UL 077 (5 ka). With
More informationProducts :: Circuit Protection :: Hydraulic/Magnetic Circuit Breakers
Products :: Circuit Protection :: Hydraulic/Magnetic Circuit Breakers Hydraulic/Magnetic Circuit Breaker B-Series B-Series PDF elibrary The B-Series hydraulic/magnetic circuit breakers are compact and
More informationRSTI-EP Slice I/O. Digital Output Module
GFK-2959B December 2015 RSTI-EP Slice I/O Digital Output Modules EP-2214, EP-2614, EP-2634, EP-2218, EP-225F Relay Output Module Solid-state Relay Output Module EP-2814 Module Status LED Channel Status
More informationFerrule fuse-links 14x51 am 500 to 690VAC
Ferrule fuse-links 4x am 0 to 690VAC Ferrule fuse-links 4x am 0 to 690VAC LOW VOLTAGE IEC FUSES IEC CYLINDRICAL FUSE-LINKS FEATURES & BENEFITS Reduced size Striker version available for remote indication
More informationFerrule fuse-links 22x58 am 500 to 690VAC
Ferrule fuse-links 22x8 am 0 to 690VAC Ferrule fuse-links 22x8 am 0 to 690VAC LOW VOLTAGE IEC FUSES IEC CYLINDRICAL FUSE-LINKS FEATURES & BENEFITS Reduced size Striker version available for remote indication
More informationC C CIRCUIT-BREAKERS Moulded-case (MCCB), general. 1. Introduction. 2. General description
CIRCUIT-BREAKERS C C81-21 CIRCUIT-BREAKERS - Contents 1. Introduction 2. General description 3. Rated voltages 3.1 Rated operational voltage (U e ) 3.2 Rated impulse withstand voltage (U imp ) 3.3 Rated
More informationSRI LANKA STANDARD CODE OF PRACTICE FOR GRID CONNECTED PHOTOVOLTAIC POWER SYSTEMS SLS 1522:2016
SRI LANKA STANDARD CODE OF PRACTICE FOR GRID CONNECTED PHOTOVOLTAIC POWER SYSTEMS SLS 1522:2016 BY H S W Karunaratne Assistant Director - Engineering Sri Lanka Standards Institution. 1 DEFINITIONS Ac module:
More informationE-STOP relay, safety gate monitor
Safety relay for monitoring E-STOP pushbuttons and safety gates. Approvals Unit features Positive-guided relay outputs: 2 safety contacts (N/O), instantaneous 1 semiconductor output Connection options
More informationResidual Current Devices drcm Digital
Digital Line voltage independent RCCB for fault or additional protection with additional digital features. System Monitoring: Preventive information / warning before the RCD trips in case of leakage currents.
More informationTime Delay Values (E-Series)
Time Delay Values (ESeries) AC Instantaneous 00 0 INSTANTANEOUS CURVE NO. 20 00 0 DC D.C. INSTANTANEOUS CURVE NO. 0 0. 0..0.0.00 200 300 400 500 700 800 900 0 200.00 200 300 400 500 700 800 900 0 200 Short
More informationE-STOP relay, safety gate monitor
Safety relay for monitoring E-STOP pushbuttons, safety gates and light barriers. Approvals Unit features Positive-guided relay outputs: 2 safety contacts (N/O), instantaneous 1 semiconductor output Connection
More informationMagnetic and Hydraulic-Magnetic Circuit Breaker
Description Single or multipole hydraulic-magnetic circuit breakers with trip-free - mechanism and toggle actuation. A choice of switching characteristics ensures suitability for a wide range of applications.
More informationProtection Equipment
Protection Equipment Price groups 41B, 41E, 41F, 41G, 41H, 41J, 42F, 42J, 143, 401 /2 Introduction Motor starter protectors/ circuit breakers SIRIUS 3RV2 motor starter protectors up to 40 A / General data
More informationPositive-guided relay outputs: 4 safety contacts (N/O), instantaneous
Contact expander module for increasing the number of available contacts Approvals Unit features Positive-guided relay outputs: 4 safety contacts (N/O), instantaneous LED indicator for: Switch status channel
More informationMotor current. Torque. Ramp-up of a three-phase asynchronous motor directly connected to the mains (at nominal load) Motor current.
Dimensioning Rules for Soft Starters.23 All data sheets and commissioning instructions are available on our homepage at: www.peter-electronic.com. Configuration instructions The two following diagrams
More informationAThink future. Switch to green. Mini Panel Board. Cost-effective, space-saving board up to 400A.
www.moeller.co.uk Mini Panel Board Cost-effective, space-saving board up to 400A Product Catalogue and Selection Guide Mini Panel Board Miniature Circuit Breakers Moulded Case Circuit Breakers XBoard Consumer
More informationE-STOP relays, safety gate monitors
Safety relay for monitoring E-STOP pushbuttons, safety gates and light barriers. Approvals Block diagram Unit features Positive-guided relay outputs: 6 safety contacts (N/O), instantaneous 4 auxiliary
More informationPositive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous
Gertebild Bildunterschrift Two-hand control device for safety circuits Approvals Zulassungen Unit features Gertemerkmale Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous 1 auxiliary
More informationResidual Current Devices FRCdM Type B, B+ and Bfq Digital
Residual Current Devices FRCdM Type B, B+ and Bfq Digital Line-voltage independent, all-current sensitive RCCB for fault or additional protection with additional digital features System Monitoring: Preventive
More informationL50QS SERIES HIGH-SPEED ROUND BODY FUSES
00 Vac/dc -0 A Traditional Round Body Bolted Style HF Specifications Voltage Rating Amperage Rating Interrupting Rating Time Constant Material Approvals Environmental Country of Origin AC: 00V DC: 00V
More informationLightning and Surge Protection of Photovoltaic Installations. Leutron GmbH 2013 Leinfelden-Echterdingen, Germany
Lightning and Surge Protection of Photovoltaic Installations 1 Lightning and Surge Protection for PV Installations 2 Safeguard from Risks Ups, that was the insurance policy of my house!! 3 Why Lightning
More information3RM1 Hybrid Starters 6SIRIUS. contents. Industrial Controls Product Catalog 2017
3RM1 Hybrid Starters Industrial Controls Product Catalog 2017 Section contents 3RM1 Compact - Hybrid Starters Overview /2 General Data /3 Selection and ordering data /4 Accessories /5 - /9 Technical Data
More informationMini Contactors. Mini Contactor Relays 4-pole 20 Auxiliary Contact Blocks. Interface Contactor Relays. Mini Contactors 22 Auxiliary Contact Blocks
Mini Contactors Mini Contactor Relays 4-pole 20 Auxiliary Contact Blocks Interface Contactor Relays Mini Contactors 22 Auxiliary Contact Blocks Mini Contactors With Fast On Tab Connectors 24 Mini Contactors
More informationSafety Relay F 121 Emergency-Stop Relay, Safety Gate Monitor
Safety Relay F 121 Emergency-Stop Relay, Safety Gate Monitor Features M Safety-category 4 acc. to DIN EN954-1 M Stop-category 0 M Crossfault monitoring M Monitored start (On-switch) or automatic start
More informationPositive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous
Safety relay for monitoring E-STOP pushbuttons. Approvals Unit features Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous 1 auxiliary contact (N/C), instantaneous Safe separation of
More informationMULTI 9 System Catalog UL Recognized C60N Supplementary Protectors
UL Recognized C60N Supplementary Protectors B Curve C60N Supplementary Protectors 1 MG24110 MG24125 MG24140 MG24155 15 MG17406 MG17436 MG17461 1.2 MG17402 MG17432 16 MG24118 MG24133 MG24148 MG24163 1.5
More informationSafety relays PNOZsigma
Safety relays PNOZsigma Configuration guide, safety relays PNOZsigma Technical catalogue 3.2 November 2008 edition Why does Pilz offer more? Because the integrality of our business activities is what sets
More informationSelection Guide. Control Circuit and Load Protection. Allen-Bradley 1489-M2C020
Selection Guide Control Circuit and Load Protection Circuit Protection Portfolio 1489-M Circuit Breakers Approved for branch circuit protection in the United States and Canada, and certified as Miniature
More information24973 Circuit Breaker MINIATURE CIRCUIT BREAKER, 440VAC, 10A, CIRCUIT BREAKER TYPE: STANDARD
United States 24973 Circuit Breaker MINIATURE CIRCUIT BREAKER, 440VAC, 10A, CIRCUIT BREAKER TYPE: STANDARD Image not available Product Information Features and Specifications Approvals: IEC 60947-2 Rated
More informationRESIDUAL CURRENT CIRCUIT BREAKERS OFE (6 ka)
Residual current circuit breakers MINIA RESIDUAL CURRENT CIRCUIT BREAKERS OFE ( ka) They react to sine-wave residual current (type AC) For protection: against dangerous contact with live parts (I Δn 30
More informationPositive-guided relay outputs: 4 safety contacts (N/O), instantaneous
ohne Abbildung Contact expansion module for increasing the number of available contacts Approvals PZE X4.1P with universal power supply Unit features Positive-guided relay outputs: 4 safety contacts (N/O),
More informationE-STOP relays, safety gate monitors
Safety relay for monitoring E-STOP pushbuttons and safety gates. Approvals Unit features Positive-guided relay outputs: 2 safety contacts (N/O), instantaneous 2 safety contacts (N/O), delay-on de-energisation
More informationFUSERBLOC and high speed fuses (ur) Fuse combination switches protection of power semi-conductors up to 1250 A
fuser_47_a_1_cat The solution for > Protection of inverters and variable speed drives FUSERBLOC 60 to 150 A Strong points > Limitation of short-circuit current Extended range fuser_49_a_1_cat FUSERBLOC
More informationProducts :: Circuit Protection :: Hydraulic/Magnetic Circuit Breakers
Products :: Circuit Protection :: Hydraulic/Magnetic Circuit Breakers Miniature Hydraulic/Magnetic Circuit Breaker M-Series M-Series PDF elibrary The M-Series miniature hydraulic/magnetic circuit breakers
More informationE-STOP relays, safety gate monitors
Safety relay for monitoring E-STOP pushbuttons and safety gates. Approvals Unit features Positive-guided relay outputs: 5 safety contacts (N/O), instantaneous 1 auxiliary contact (N/C), instantaneous Connection
More informationTeSys IEC Contactors and Overload Relays
TeSys IEC Contactors and Overload Relays Making High-Fault Short-Circuit Current Ratings Simple Schneider Electric is an industry leader in IEC contactors and overload relays, and is recognized as the
More informationDC-Switch With G20S/G20. next
DC-Switch With knife contacts G2S/G2 www.krausnaimer.com next Content The most important technical data: G2S / G2... 3 Electrical data of ON/OFF-Swichtes: G2S / G2... 4 Electrical data of Change Over Switches:
More informationELR W1/ 6-24DC. Extract from the online catalog. Order No.:
Extract from the online catalog ELR W1/ 6-24DC Order No.: 2982090 Illustration shows item ELR W1/ 6-24DC Electronic reversing load relay, for driving DC motors, with light indicator and protection circuit,
More informationGB/T / IEC :2006
Translated English of Chinese Standard: GB/T14048.2-2008 www.chinesestandard.net Sales@ChineseStandard.net GB NATIONAL STANDARD OF THE PEOPLE S REPUBLIC OF CHINA ICS 29.120.40 K 31 GB/T 14048.2-2008 /
More informationCircuit Breakers Type CTI 25M, CTI 45MB
Data sheet Circuit Breakers Type CTI 25M, CTI 45MB Circuit breakers for short circuit and overload protection of motor applications cover the current range 0.1 45 A (AC-3 rating). The product range is
More informationMiniature Circuit-Breaker IEC Series 8562
> 1 to 3 pole versions > Rated current from 0.5... 40 A > 6 or 10 ka breaking capacity to DI VDE 0641, respectively E 60898 > Isolating Function to E 60947-2 > Permanently set thermal and magnetic trips
More informationEXPANSION PERIPHERAL CVM-R10 C. (Code ) INSTRUCTION MANUAL ( M / 00 A ) (c) CIRCUTOR S.A.
EXPANSION PERIPHERAL CVM-R10 C (Code 7 70 217 ) INSTRUCTION MANUAL ( M 981 170 / 00 A ) (c) CIRCUTOR S.A. ------ CVM-R10 C Peripheral --------------- Pag. 1 CVM-R10C EXPANSION PERIPHERAL 1.- DESCRIPTION
More informationOperating instructions Evaluation system for flow sensors VS / / 2013
Operating instructions Evaluation system for flow sensors VS3000 7097 / 0 07 / 203 Contents Preliminary note...2 2 Safety instructions...3 3 Function and features... Mounting.... Mounting of the sensors...
More informationSafety Switching Devices SNO 4003K. Basic device for Emergency-Stop and Safety Gate Applications PI E
EN 60204-1 Stop category 0 EN 954-1 Safety category 4 Basic device to EN 60204-1 and EN 954-1 single E-stop monitoring. Manual or automatic start Application up to safety category 2 and stop category 0
More informationBusbar Systems. 10/2 Introduction. 10/3 General data. 40 mm Busbar Systems 10/6 Introduction 10/7 Base assemblies up to 400 A
Siemens AG 20 Busbar Systems /2 Introduction /3 General data 40 mm Busbar Systems /6 Introduction /7 Base assemblies up to 400 A mm Busbar Systems /8 Introduction /9 Base assemblies up to 630 A /13 Base
More information5/2 Product overview. 5/3 Distribution board components. 5/9 Built-in components. 5/17 Mounting components 5. Siemens ET B1 10/2009
Siemens AG 9 BETA Protecting SR Busbar Systems /2 Product overview /3 Distribution board components /9 Built-in components /17 Mounting components Siemens ET B1 10/9 BETA Protecting SR Busbar Systems Siemens
More informationIELR Rail-Mount Series Magnetic Circuit Protectors
IELR Rail-Mount IELR Rail-Mount Series Magnetic Circuit Protectors Introduction 92 Single Pole 93 Specifications 94 Operating Characteristics 95 Delay Curves 96 Approvals & Decision Tables 200 IELR Series
More informationApplying branch circuit breakers and supplementary protectors in North America
Product Application AP01102005E WMZT WMZS Applying branch circuit breakers and supplementary protectors in North America Introduction Eaton offers two types of miniature circuit breakers for use in North
More informationRB60 RANGE. Miniature circuit breakers
RB60 RANGE Miniature circuit breakers POWER 2015 RB60 range Miniature circuit breakers Miniature circuit breakers for circuit protection The miniature circuit breakers RB60 are designed for the protection
More informationST 200 M data sheet System pro M compact miniature circuit breakers for supplementary protection acc. to UL 1077
MINIATURE CIRCUIT BREAKERS ST 200 M data sheet System pro M compact miniature circuit breakers for supplementary protection acc. to UL 1077 The ST 200 M miniature circuit breaker provides supplementary
More informationPush buttons and selectors
Accessories and spare parts 8 LM2T A130 8 LM2T A140 8 LM2T A185 8 LM2T AL... Order code Description Qty per Wt 8 LM2T A12❶ Coloured diffuser for 10 0.001 double touch buttons 8 LM2T A130 Threaded plug
More information60103 Circuit Breaker
6003 Circuit Breaker United States MINIATURE CIRCUIT BREAKER, 20/240VAC, 2A, CIRCUIT BREAKER TYPE: STANDARD Image not available Product Information Features and Specifications Circuit Breaker Type: Standard
More informationIMS Control & EPR, We keep your motors running ABB s new control & protection devices up to 18.5 kw / 20 hp
IMS Control & EPR, 2010 01 29 We keep your motors running ABB s new control & protection devices up to 18.5 kw / 20 hp October 27, 2010 1SBC101089D0201 ABB s new control and protection devices Up to 18.5
More informationvoltage surge protectors low voltage type 1 (class I / B) voltage surge protectors low voltage type 2 (class II / C) Distribution board protection
voltage surge protectors low voltage type 1 (class I / B) voltage surge protectors low voltage type 2 (class II / C) 030 23 030 28 039 21 039 33 039 34 Type 1 voltage surge protectors (V.S.P.) for main
More informationConveyor Belt Alignment Switches from IDEM
Conveyor Belt Alignment Switches from IDEM Data Sheet Die-Cast Models Python Line Series Stainless Steel Models Using Conveyor Belt Alignment Switches Application: Conveyor Belt Alignment switches are
More informationPositive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous
Two-hand control unit for press controllers and safety circuits Approvals Unit features Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous 1 auxiliary contact (N/C), instantaneous 1
More informationUL 489 DIN Rail Miniature Circuit Breakers
UL 9 DIN Rail Miniature Circuit Breakers Product Overview................................................ Product Selection................................................ Accessories.....................................................
More informationUL 508A Industrial Control Panels Eaton. All Rights Reserved.
UL 508A Industrial Control Panels Objectives Who is UL? UL508A Origin Current emphasis on UL508A What is the UL 508A Standard? Implementation of the Standard Component Selection Short Circuit Current Ratings
More informationOriginal operating instructions Safety relay with relay outputs with and without delay G1502S / / 2016
Original operating instructions Safety relay with relay outputs with and without delay UK G50S 803638 / 00 0 / 06 Contents Preliminary note...4. Symbols used...4 Safety instructions...5 3 Items supplied...6
More informationMagnetic and Hydraulic-Magnetic Circuit Breaker 8340-F...
Magnetic and Hydraulic-Magnetic Circuit Breaker 830-F... Description Single and multipole magnetic circuit breakers with trip-free mechanism and toggle actuation. A choice of fast magnetic only or hydraulically
More informationDescription. Installation. Power supply
Air circuit breakers Special versions Series MEGT07 0V/500V/DC 50 up to 5000 A The air circuit breakers MEGT07 are suitable for use as disconnecting switch in DC distributions up to a rated voltage of
More informationOvervoltage Protection Devices
Siemens AG 2010 Overvoltage Protection Devices /2 Introduction /3 Lightning Arresters, Type 1 /5 Combination Surge Arresters, Type 1 and Type 2 /7 Surge Arresters, Type 2 /11 Surge Arresters, Type 3 /12
More informationMagnetic and Hydraulic-Magnetic Circuit Breaker 8340-F...
Description Single and multipole magnetic circuit breakers with trip-free mechanism and toggle actuation. A choice of fast magnetic only or hydraulically delayed switching characteristics (S-type MO or
More information