1 from 0. to 0 A Fuse protection The solution for > Motor protection > Cable and device protection fusib a cat fusib_0_c cat fusib b cat Strong points gg fuse from 0. to A > High level performances > High reliability > Improved safety am type fuse from to 0 A gg fuse from to 0 A Conformity to standards > IEC 0- > DIN EN 0- > NF EN 0- > IEC 0- > NF EN 0- Function SOCOMEC industrial fuses protect installations and people from overcurrents for any low voltage electrical circuit. Advantages High level performances High breaking capacity - 0 ka at 00/00 V, 0 ka at 0 V. High short-circuit limitation capacity. Simple and reliable discrimination. Improved safety The energy released whilst eliminating the fault (fuse blowing) is contained within the cartridge (no degassing). High reliability Absolute protection over time guaranteed by the simplicity of manufacture and function (Joule effect). No downgrading of fuse characteristics over time. General Catalogue 0-0
2 from 0. to 0 A s gg type fuses (in multiples of 0) 0 x x x x x Solid cylindrical link am type fuses (in multiples of 0) 0 x x x x x Solid cylindrical link General Catalogue 0-0
3 from 0. to 0 A s (continued) Knife-edge fuses (NH), gg type 000/00C (in multiples of ) (in multiples of ) 0 (in multiples of ) (in multiples of ) (in multiples of ) (in multiples of ) Neutral bar (in multiples of ) (in multiples of ) Neutral bar General Catalogue 0-0
4 from 0. to 0 A Knife-edge fuses (NH), am type 000/00C (in multiples of ) (in multiples of ) 0 (in multiples of ) (in multiples of ) (in multiples of ) (in multiples of ) Neutral bar (in multiples of ) (in multiples of ) Neutral bar General Catalogue 0-0
5 from 0. to 0 A Accessories Solid cylindrical link Use Solid link to be used in conjunction with the neutral pole of cylindrical fused disconnecting switches. sizes: 0 x, x, x. Size To be ordered in multiples of 0 x x x fusib a cat Solid links Use Solid link to be used in conjunction with fuse bases or knife-edge fused disconnecting switches, generally fitted on the neutral pole. sizes: 000/00C/ Size Tightening 0 000/00C/00 elastic elastic 0000 elastic elastic elastic blocked 000 fusib a cat Operating handle Use For inserting and extracting knife-edge fuses, sizes 000 to. Type Operating handle 0 00 fusib a cat General Catalogue 0-0
6 from 0. to 0 A Dimensions Cylindrical fuses (NF) Without striker - fusib_0_b x_cat A C B D E Standard dimensions (mm) as per IEC 0-- Size A B C D E 0 x x.... x.... fusib_0_b x_cat Knife-edge fuses (NH) Standard dimensions (mm) as per IEC 0-- F A E D B C G I X H Size A B mini C D E mini F G H I X mini 000/00C With striker fusib_0_c x_cat M M F E A D B C K G X L H I Standard dimensions (mm) as per IEC 0-- Size A B mini C D E F G H I K L M M mini X mini General Catalogue 0-0
7 from 0. to 0 A Curves characteristic of NF and NH gg type fuses Cut-off current diagram, 00 ka cr , 00 0 ka Cut-off current ka peak ka, gg fuse rated current, 00 A,,, catec f gb_cat 0 A 00 A ka 0 ka 00 ka eff. Prospective current in A rms 0 General Catalogue 0-0
8 from 0. to 0 A Diagram of thermal constraint limitation catec c gb_cat I t (Amperes seconds ) gg fuse rated current catec c fr_cat 0 V 00 V 0 V A t of pre-arcing A t total at rated voltages Time/current operation characteristics catec c gb_cat Pre-arcing time (s) , , 0, 0, 0, 0, 0, 0, 0,0 0,0 0,0 0,0 0,0 0,00 0,00 0, 0,, Fuse In (A) ,,,, A 0 A 00 A ka 0 ka 00 ka eff. Prospective current (A eff) General Catalogue 0-0
9 from 0. to 0 A Curves characteristic of NF and NH am type fuses Cut-off current diagram I C (ka) Cut-off current (ka peak) am fuse rated current 0, I p (ka) catec g gb_cat 0, 0 00 Prospective current in ka rms General Catalogue 0-0
10 from 0. to 0 A catec c gb_cat Diagram of thermal constraint limitation I t (Amperes seconds ) catec c gb_cat 0 V 00 V 0 V A t of pre-arcing A t total at rated voltages am fuse rated current Dissipated power (W) Rated operational currents Fuse size In (A) /0S Time/current operation characteristics In fusibles (A) Pre-arcing time (s) 0 0, 0,0 catec d gb_cat Prospective current (A eff) General Catalogue 0-0
Ferrule fuse-links 10x38 gg 400 to 690VAC
Ferrule fuse-links x8 gg 400 to 690VAC Ferrule fuse-links x8 gg 400 to 690VAC LOW VOLTAGE IEC FUSES IEC CYLINDRICAL FUSE-LINKS FEATURES & BENEFITS Reduced size Full range protection Visual indication of
More informationFerrule fuse-links 14x51 am 500 to 690VAC
Ferrule fuse-links 4x am 0 to 690VAC Ferrule fuse-links 4x am 0 to 690VAC LOW VOLTAGE IEC FUSES IEC CYLINDRICAL FUSE-LINKS FEATURES & BENEFITS Reduced size Striker version available for remote indication
More informationFerrule fuse-links 22x58 am 500 to 690VAC
Ferrule fuse-links 22x8 am 0 to 690VAC Ferrule fuse-links 22x8 am 0 to 690VAC LOW VOLTAGE IEC FUSES IEC CYLINDRICAL FUSE-LINKS FEATURES & BENEFITS Reduced size Striker version available for remote indication
More informationNH fuse-links gg VAC with striker size 0, 1, 2, 3, 4
NH fuse-links gg - 690VAC LOW VOLTAGE IEC FUSES IEC NH FUSE-LINKS FEATURES & BENEFITS Dimensions according to DIN 43 620 Parts 1 to 4 Lead free contact blades 0% cadmium APPLICATIONS gg: General purpose
More informationFUSERBLOC LMDC Fuse combination switches FUSERBLOC Live Maintenance DC
Fuse protection The solution for > Live maintenance of speed drives supplied by a common DC bus > Live maintenance of PV inverters connected in parallel on a same circuit fuser-lm_2_a Strong points > Compact
More informationProtistor size 22x58 ar 690VAC (IEC) / 700VAC (UL)
690VAC (IEC) / VAC (UL) Protistor size 22x58 ar 690VAC (IEC) / VAC (UL) SEMICONDUCTOR PROTECTION FUSES IEC HIGH-SPEED CYLINDRICAL FUSE-LINKS AC PROTECTION FEATURES & BENEFITS Low l²t for improved semiconductor
More informationProtistor size 14x51 gr 690VAC (IEC) / 700VAC (UL)
690VAC (IEC) / 0VAC (UL) Protistor size 4x gr 690VAC (IEC) / 0VAC (UL) SEMICONDUCTOR PROTECTION FUSES IEC HIGH-SPEED CYLINDRICAL FUSE-LINKS AC PROTECTION FEATURES & BENEFITS IEC standard 60269-4 compliant
More informationSOCOMEC SIRCOVER MANUALLY OPERATED CHANGEOVER SWITCHES
MANALL OPERATED CHANGEOER SWITCHES are manually operated multipolar changeover switches. They changeover between two low voltage power circuits under load and provide safety disconnection. Application:
More informationVarius SUMMARY OF MODELS OF HRC FUSE-LINKS
SUMMARY OF MODELS OF HRC FUSE-LINKS PNA000 PHNA000 PNA00 PHNA00 Rated current I n up to A up to 0 A up to A up to 0 A Rated voltage U n AC 00 V, 00 V 90 V 00 V 90 V DC 0 V 0 V 0 V 0 V Fuse-link size 000
More informationLimitor - PD Back-up Fuses without Controlled Power Dissipation
Limitor - PD Back-up Fuses HIGH VOLTAGE IEC FUSES DIN HV BACK-UP FUSES FOR TRANSFORMERS FEATURES & BENEFITS Mersen HV fuse-links have been used for reliable protection in high-voltage switchgear and controlgear
More informationProtistor size 14x51 gr 690VAC (IEC) / 700VAC (UL)
690VAC (IEC) / VAC (UL) Protistor size 4x5 gr 690VAC (IEC) / VAC (UL) SEMICONDUCTOR PROTECTION FUSES IEC HIGH-SPEED CYLINDRICAL FUSE-LINKS AC PROTECTION FEATURES & BENEFITS IEC standard 60269-4 compliant
More informationDX 3 MCB A / 16 ka 80 A to 125 A (1,5 module per pole)
87045 LIMOGES Cedex Telephone: +33 5 55 06 87 87 FAX: +33 5 55 06 88 88 DX 3 MCB 10000 A / 16 ka CONTENTS PAGES 1. Description - Use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection...
More informationIDE Load break switches for machine control Remotely trippable switch from 32 to 160 A
The solution for Load break switches > Industry. > Non critical buildings. > Public Access Sites. > High Rise Buildings. ide_021_a_1_cat ide_022_a_1_cat IDE 4x40 A External operation IDE 4x40 A Direct
More informationSection 4 Ground-Fault Protection Devices
Multi 9 System Catalog Section 4Ground-Fault Protection Devices Section 4Ground-Fault Protection Devices Selection Table The Multi 9 System includes one UL Listed and three IEC rated product families that
More information3 Design of the electrical installation protection system
J - Protection against voltage surges in LV 3 Design of the electrical To protect an electrical installation in a building, simple rules apply for the choice of b (s); b its protection system. 3.1 Design
More informationFAZ Supplementary Protectors, FAZ Miniature Circuit Breakers, P2 Disconnect Switches Overview
FAZ Supplementary Protectors, FAZ Miniature Circuit Breakers, P2 Disconnect Switches Overview Supplementary Protectors / Miniature Circuit Breakers Page System overview 10/003 10/001 Supplementary protectors
More information63 to 125 A. Functions. Conformity standards. General characteristics. Changeover switches SIRCO VM1 changeover switches.
comut_004_a_1_cat Changeover switches switches 63 to 125 A switches are manually operated three or four pole switches. They provide, source inversion or switching under load between two low voltage power
More informationC C CIRCUIT-BREAKERS Moulded-case (MCCB), general. 1. Introduction. 2. General description
CIRCUIT-BREAKERS C C81-21 CIRCUIT-BREAKERS - Contents 1. Introduction 2. General description 3. Rated voltages 3.1 Rated operational voltage (U e ) 3.2 Rated impulse withstand voltage (U imp ) 3.3 Rated
More informationMULTI-POLE PHOTOVOLTAIC SYSTEMS. COMPACT and MODULAR Housing
MULTI-POLE Lightning Current and Surge Arresters for PHOTOVOLTAIC SYSTEMS Class I / (B+C) and Class II / (C) COMPACT and MODULAR Housing 44 PV ISPRO BS(R) 12,5 The PV ISPRO BS(R) 12,5 series of over voltage
More informationFUSERBLOC UL Fusible disconnect switches UL and CSA from 30 to 800 A
Fuse protection The solution for > Motor on-load disconnect > Protection of industrial cabinet > Electrical distribution ul_004_a Strong points fuser-ul_006_a Function FUSERBLOC UL fusible disconnect switches
More informationSurge Protection Devices and Surge Protection Kit
Surge and Surge Kit SPD s protect electrical and electronic equipment against transients, originating from lightning, switching of transformers, lighting and motors 3. Main protection - class 3 To cut-down
More informationIssued February DATA SHEET 5SX2 MCB. Based on Siemens Industrial Control Catalog
Issued February 2011 DATA SHEET 5SX2 MCB Based on Siemens Industrial Control Catalog General Data Trip characteristics Tripping characteristics acc. to EN 60 898 Tripping characteristic A, -5 Type A characteristic
More informationProtistor size 2x72 and 2x73 ar 550 to 1250VAC (IEC)
Protistor size 2x72 and 2x73 ar SEMICONDUCTOR PROTECTION FUSES SQUARE BODY HIGH-SPEED FUSE-LINKS AC PROTECTION FEATURES & BENEFITS Multiple body sizes and terminals or blades combination ar Class according
More informationNon-Fusible Disconnect Switches
UL 98 and IEC, Non-Fused Switches Mersen s non-fusible disconnect switches are listed to UL 98 and bear the CE mark as conformance to IEC 60947-3. They are service entrance devices that are capable of
More informationNV disconnectors with fuses
NV disconnectors with fuses Horizontal fuse-switch disconnector type HVL size 00,, 2, and 4a Description Horizontal fuse-switch disconnector type HVL are designed to be used in most demanding fields of
More informationMicro Contactor MA Series
Relay-sized contactor, making it the world s smallest >3mm contact clearance acc. to IEC 60335-1 for Safety Applications Reversing contactor with mechanical interlock 3 Pole and 1 Aux. Contact NO or NC
More informationBasic Efficiency. NH Fuse-Bases 3-pole. NH Fuse-Bases up to 1500 V. NH Fuse-Bases 1-pole. NH Fuse-Bases, SILAS
Basic Efficiency up to 1500 V 1-pole 3-pole, SILAS MM: Bild angeben Content 690 V AC for baseplate, busbar and supporting rail mounting 58 Accessories 60 Technical Data see page 63 NU System The EFEN successfully
More informationBulletin 194R Fused and Non-Fused Disconnects Product Selection
Product Selection 4th Pole Modules Maximum Hp Ratings Rated 1-Phase (60 Hz) -Phase (60 Hz) DC Current [A] 1V 240V 240V 480V V 12V V Ref. Non-d 0 2 7. 1 A2 194R-0-NN 60 1 0 40 B2 194R-60-NN UL Class CC
More informationNon-Fusible Disconnect Switches
UL 98 and IEC, Non-Fused Switches Mersen s non-fusible disconnect switches are listed to UL 98 and bear the CE mark as conformance to IEC 60947-3. They are service entrance devices that are capable of
More informationWMS SUPPLEMENTARY PROTECTORS
WMS Supplementary Protectors Overview WMS SUPPLEMENTARY PROTECTORS Product Specification The WMS Supplementary Protector is a dual-rated product for both AC and DC supplies, in accordance with UL 1077
More informationFUSERBLOC and high speed fuses (ur) Fuse combination switches protection of power semi-conductors up to 1250 A
fuser_47_a_1_cat The solution for > Protection of inverters and variable speed drives FUSERBLOC 60 to 150 A Strong points > Limitation of short-circuit current Extended range fuser_49_a_1_cat FUSERBLOC
More informationNow even more application possibilities In all facets of semiconductor protection
Semiconductor Protection Fuses sitor ENGINEERING s Now even more application possibilities In all facets of semiconductor protection For decades now, SITOR semiconductor protection fuses have been reliably
More informationFUSERBLOC UL Fusible disconnect switches UL and CSA 30 to 800 A
Fuse protection The solution for > Motor load break. > Protection of industrial cabinet. > Electrical distribution. ul_004_a Strong points fuser-ul_006_a Function FUSERBLOC UL fusible disconnect switches
More informationSelection Guide. Control Circuit and Load Protection. Allen-Bradley 1489-M2C020
Selection Guide Control Circuit and Load Protection Circuit Protection Portfolio 1489-M Circuit Breakers Approved for branch circuit protection in the United States and Canada, and certified as Miniature
More informationBulletin 194R Fused and Non-Fused Disconnects Product Selection
Product Selection 4th Pole Modules Maximum Hp Ratings Rated 1-Phase (60 Hz) -Phase (60 Hz) DC Current [A] 10V 40V 40V 480V V 1V 0V Ref. Cat. No. Non-d 0 7. 1 0 A 194R-0-NN 60 1 0 40 B 194R-60-NN UL Class
More informationApplying branch circuit breakers and supplementary protectors in North America
Product Application AP01102005E WMZT WMZS Applying branch circuit breakers and supplementary protectors in North America Introduction Eaton offers two types of miniature circuit breakers for use in North
More informationDisconnect Switches. Safe Switching and Disconnecting
IB105-UK_U1_U4_Pfade.indd 2-3 14.04.2005, 16:51:30 Disconnect Switches Safe Switching and Disconnecting Disconnect Switches from Salzer are hand-operated switchgear for main circuits and are offered as
More information4. CIRCUIT BREAKERS. Functional Emergency Switching
4. CIRCUIT BREAKERS The circuit breaker/disconnector fulfils all of the basic switchgear functions, while, by means of accessories, numerous other possibilities exist. As shown in table H2-19 the circuit
More informationApplying branch circuit breakers and supplementary protectors in North America
Supersedes June 2017 FAZ-NA-L FAZ-NA FAZ Applying branch circuit breakers and supplementary protectors in North America Introduction Eaton offers three types of miniature circuit breakers for use in North
More informationReinforced discrimination
Reinforced discrimination Compact NSX Additional characteristics Contents Presentation Functions and characteristics A- Installation recommendations B- Dimensions and connection C- Wiring diagrams D- Compact
More informationK1F037MCH cam voltmeter switch - 3L and 3L-N A - for Ø 22 mm
Characteristics cam voltmeter switch - 3L and 3L-N - 60-12 A - for Ø 22 mm Main Range of product Product or component type Component name [Ith] conventional free air thermal current Mounting location Fixing
More informationComplete UL/CSA Disconnect Switch Kits
Product Selection Complete UL/CSA Disconnect Switch Kits Includes disconnect switch, operating handle with defeater mechanism and operating shaft, NFPA handle, auxiliary contacts, and padlock attachment.
More informationDIRIS Digiware D and C Communication and control power interfaces
Multi-circuit metering and measurement diris-dw_006_a_us_cat diris-dw_142_a The solution for > Industry > Building > Infrastructure > Data centers DIRIS D-40/D-50/D-70 Centralization and display of data
More informationMiniature Circuit-Breaker IEC Series 8562
> 1 to 3 pole versions > Rated current from 0.5... 40 A > 6 or 10 ka breaking capacity to DI VDE 0641, respectively E 60898 > Isolating Function to E 60947-2 > Permanently set thermal and magnetic trips
More informationPRF1 12.5r/PRF1 Master/ PRD1 25r/PRD1 Master Type 1 and 2 LV surge arresters
Type 1 and 2 LV surge s The Type 1 range of surge s meets the normative withstand capability of wave type 10/350 μs (8/20 μs for Type 2 surge s). It is suitable for use with, TN-C and 230 V IT earthing
More informationMini Contactors. Mini Contactor Relays 4-pole 20 Auxiliary Contact Blocks. Interface Contactor Relays. Mini Contactors 22 Auxiliary Contact Blocks
Mini Contactors Mini Contactor Relays 4-pole 20 Auxiliary Contact Blocks Interface Contactor Relays Mini Contactors 22 Auxiliary Contact Blocks Mini Contactors With Fast On Tab Connectors 24 Mini Contactors
More informationK1C024B body for BCD encoded output switch - 1 pole A - for Ø 22 mm
Characteristics body for BCD encoded output switch - 1 pole - 45-12 A - for Ø 22 mm Main Range of product Product or component type Component name [Ith] conventional free air thermal current Sub-assembly
More informationK1B004TLH cam switch - 1 pole A - screw mounting
Characteristics cam switch - 1 pole - 30-12 A - screw mounting Main Range of product Product or component type Component name [Ith] conventional free air thermal current Product mounting Fixing mode Cam
More informationDIN Series MINIATURE CIRCUIT BREAKERS, RESIDUAL CURRENT CIRCUIT BREAKERS. Introducing the DIN Series High-quality, high-performance circuit breakers
DIN Series MINIATURE CIRCUIT BREAKERS, RESIDUAL CURRENT CIRCUIT BREAKERS Introducing the DIN Series High-quality, high-performance circuit breakers Features (1) All models fully comply with IEC regulations
More informationDIRIS Digiware Measurement and monitoring system for electrical installations
Multi-circuit metering & new diris-dw_006_a_cat diris-dw_005_a_cat diris-dw_004_a_cat The solution for > ndustry > Building > nfrastructure > Local authority Configuration with EasyConfig, see page 42.
More informationK1D012ULH cam changeover switch - 2-pole A - screw mounting
Characteristics cam changeover switch - 2-pole - 90-12 A - screw mounting Main Range of product Product or component type Component name [Ith] conventional free air thermal current Product mounting Fixing
More informationMagnetic and Hydraulic-Magnetic Circuit Breaker
Description Single or multipole hydraulic-magnetic circuit breakers with trip-free - mechanism and toggle actuation. A choice of switching characteristics ensures suitability for a wide range of applications.
More informationCylindrical fuse links gg/gl and am
Supersedes April 2017 BUSSMANN SERIES Product description Eaton s Bussmann series Cylindrical fuse links, class gg/gl and am, are suitable for industrial applications. Standard features Compact design
More informationJtec 10kA Miniature Circuit Breaker
Jtec 0kA Miniature Circuit Breaker EN 60898 The Jtec range has been enthusiastically adopted by a diverse range of customers seeking a cost effective 0kA performance. Jtec MCBs are available in a wide
More informationECNR/ECSR Class RK5 Dual-Element Time-Delay Fuses. Catalog Number ECNR (1-600A) 250Vac or Less Catalog Number ECSR (1-600A) 600Vac or Less
Catalog Number ECNR ( - 600A) 250Vac or Less Catalog Number ( - 600A) 600Vac or Less Amp Ratings ECNR 8 25 70 50 400 2 9 30 75 75 450 3 35 80 200 500 4 2 40 90 225 600 5 5 45 250 6 7.5 50 300 7 20 60 25
More informationLow voltage. Acti 9. the efficiency you deserve. Catalogue 03/2016
Low voltage Acti 9 the efficiency you deserve Catalogue 03/2016 schneider-electric.com 1 and 2 LV surge s 1 and 2 LV surge s (cont.) The 1 range of surge s meets the normative withstand capability of wave
More informationDIRIS A-30 Multifunction power metering & monitoring device - PMD
Single-circuit metering, measurement & analysis The solution for > Industry > Building > Infrastructures diris_986_a_us.psd Strong points Function The is a power metering and monitoring device that provides
More informationK1D004ACH cam switch - 4-pole A - for Ø 22 mm
Characteristics cam switch - 4-pole - 45-12 A - for Ø 22 mm Main Range of product Product or component type Component name [Ith] conventional free air thermal current Mounting location Fixing mode Cam
More informationUL 98 Fusible Disconnect Switches
UL 98 Fusible Mersen s fusible disconnect switches are listed to UL 98 and bear the CE mark as conformance to IEC 60947-3. They are service entrance devices capable of fully rated load-break and load-make.
More informationK1K015NZ4 cam stepping switch - 2-pole A - screw mounting
Characteristics cam stepping switch - 2-pole - 60-12 A - screw mounting Complementary Number of steps 5 Main Range of product Product or component type Component name [Ith] conventional free air thermal
More informationType 1 Arresters. Use in installations with short-circuit currents up to 100 ka rms DEHN + SÖHNE / protected by ISO 16016
Type 1 Arresters Use in installations with short-circuit currents up to 100 ka rms Definition of follow current, follow current extinguishing capability and short-circuit withstand capability Follow current
More informationRATINGS AND SPECIFICATIONS
RATINGS AND SPECIFICATIONS MCCB ELECTRICAL CHARACTERISTICS TO IEC 609472, EN 609472, JIS C 121 ANN.1, AS/NZS 39472, NEMA AB1 Frame Quantity Unit Condition 125 Model E125 S125 Number of Poles 1 Type NJ
More information10 SEC TIME DELAY (AT 500 PERCENT RATED LOAD), DUAL ELEMENT
3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 AllenWatson@elliottelectric.com Catalog Number Manufacturer Description Weight per unit Product Category Features Characteristics
More informationMULTI 9 System Catalog
MULTI 9 System Catalog Class 80 CONTENTS Page Schneider Electric Brands Section Introduction... Section UL Rated Protection Devices... Section IEC 097- Rated Protection Devices... Section IEC Rated Ground-fault
More informationthe Santon FCS-type switch Disconnect Superior Switch Solutions
the Santon FCS-type switch Disconnect Superior Switch Solutions The technical information given in this table applies to 3 and 4 pole fuse combination switches. FRAME SIZE 1 1 2 3 3 4 4a 4b 5 6 6 nominal
More informationRB60 RANGE. Miniature circuit breakers
RB60 RANGE Miniature circuit breakers POWER 2015 RB60 range Miniature circuit breakers Miniature circuit breakers for circuit protection The miniature circuit breakers RB60 are designed for the protection
More informationTeSys IEC Contactors and Overload Relays
TeSys IEC Contactors and Overload Relays Making High-Fault Short-Circuit Current Ratings Simple Schneider Electric is an industry leader in IEC contactors and overload relays, and is recognized as the
More informationSemiconductor (AC) fuses
Main characteristics 450 TO 700VAC / 63 TO 2800A Recognized Exceptionally low I 2 T, Watt losses. Non-magnetic construction, Highly reliable low voltage Trip-indicator system, conformity to UL, IEC, DIN
More informationSIRCO Load break switches for power distribution from 125 to 5000 A
The solution for Load break switches sirco_456_a_1_cat > Main switchboard > Distribution panel > Emergency breaking > Network coupling > Local safety breaking sirco-ac_001_a_1_cat SIRCO 3 x 250 A direct
More informationUL 489 DIN Rail Miniature Circuit Breakers
UL 9 DIN Rail Miniature Circuit Breakers Product Overview................................................ Product Selection................................................ Accessories.....................................................
More informationK1F006ALH cam switch - 6-pole A - screw mounting
Characteristics cam switch - 6-pole - 45-12 A - screw mounting Complementary Main Range of product Product or component type Component name [Ith] conventional free air thermal current Product mounting
More informationK1D011B body for BCD encoded output switch - 1 pole A - for Ø 22 mm
Characteristics body for BCD encoded output switch - 1 pole - 30-12 A - for Ø 22 mm Complementary Main Number of decimal 11 Switching angle 30 Range of product Product or component type Component name
More informationThe safest way to switch power on and off in your industrial control panels.
The safest way to switch power on and off in your industrial control panels. Your problem: You need a range of disconnect switches for your industrial control requirements ranging from Service Entrance
More informationOTEC Miniature Circuit Breakers (MCB) OTEC Miniature Circuit Breakers (MCB) OTEC Miniature Circuit Breakers (MCB) Areas of Application
Miniature Circuit Breakers Areas of Application Miniature circuit breakers (MCBs) of the N-System primarily protect cables and conductors against overload and short circuit. Thus, they also protect electrical
More informationUL 489 DIN Rail Miniature Circuit Breakers
UL 489 DIN Rail Miniature Circuit Breakers Product Overview................................................ 2 Product Selection................................................ 4 Accessories.....................................................
More informationMini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protectors Specifications Bulletin Number 1492, 1692
Technical Data Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protectors Specifications Bulletin Number 1492, 1692 Topic Page 1489-M Miniature Circuit Breakers 1 1492-SP Supplementary Protectors
More informationThe City of Winnipeg Dry Type Transformers up to 600 V Primary Section Bid Opportunity No Page 1 of 2
The City of Winnipeg Dry Type Transformers up to 600 V Primary Section 26121601 Bid Opportunity No. 1196-2014 Page 1 of 2 Part 1 General 1.1 RELATED REQUIREMENTS.1 Section 26 05 01 - Common Work Results
More information1492-SP Supplementary Protectors
Dual terminals provide wiring/bus bar flexibility and clamp from both sides to improve connection reliability Approval marks are easily visible on dome Terminal design helps prevent wiring misses Scratch-
More informationTeSys contactors From 115 to 2750 A
Selection guide From to 0 A Applications Control of all types of motor for standard or severe duty applications Control of resistive, inductive and capacitive circuits: heating, lighting, cos j rectification,
More information24973 Circuit Breaker MINIATURE CIRCUIT BREAKER, 440VAC, 10A, CIRCUIT BREAKER TYPE: STANDARD
United States 24973 Circuit Breaker MINIATURE CIRCUIT BREAKER, 440VAC, 10A, CIRCUIT BREAKER TYPE: STANDARD Image not available Product Information Features and Specifications Approvals: IEC 60947-2 Rated
More informationSECTION OVERCURRENT PROTECTIVE DEVICE COORDINATION STUDY
SECTION 26 05 73 OVERCURRENT PROTECTIVE DEVICE PART 1 - GENERAL 1.1 SUMMARY A. Section includes computer-based, fault-current and overcurrent protective device coordination studies. Protective devices
More informationMULTI 9 System Catalog UL Recognized C60N Supplementary Protectors
UL Recognized C60N Supplementary Protectors B Curve C60N Supplementary Protectors 1 MG24110 MG24125 MG24140 MG24155 15 MG17406 MG17436 MG17461 1.2 MG17402 MG17432 16 MG24118 MG24133 MG24148 MG24163 1.5
More information1.3. Miniature Circuit Breakers and Supplementary Protectors. Contents. WMZS Circuit Breaker. UL 1077 DIN Rail Supplementary Protectors
. Miniature Circuit Breakers and Supplementary Protectors UL 077 DIN Rail Supplementary Protectors WMZS Circuit Breakers Contents Description WMZS Circuit Breaker Standards and Certifications................
More informationMotor protection relays
Thermal overload relays for currents between 0.09 and 420A Electronic thermal overload relays for currents between 0.4 and A Electronic thermal overload relays with selectable tripping class: 5--20-30
More informationAllen-Bradley 1492-RCDA4A40
Dual terminals provide wiring/bus bar flexibility and clamp from both sides to improve connection reliability Suitable for DIN Rail mounting Approval marks are easily visible on dome Terminal design helps
More informationDescription. Installation. Power supply
Air circuit breakers Special versions Series MEGT07 0V/500V/DC 50 up to 5000 A The air circuit breakers MEGT07 are suitable for use as disconnecting switch in DC distributions up to a rated voltage of
More informationIncreased Safety for Switchgear Cabinets CI Arresters with Integrated Backup Fuse
Increased Safety for Switchgear Cabinets CI Arresters with Backup Fuse www.dehn-international.com 1 fuse 1 2 fuse monitoring 2 3 Considerable space saving 3 Innovative solution to save space in the switchgear
More information3 Pole Contactors with AC operating coils
1 3 Pole Contactors with AC operating coils Characteristics General Characteristics Switching Current 9A ~ Rated insulation voltage (Ui) (Conforming to IEC 158-1) V 750 IEC 60947-4 V 1000 Conforming to
More informationProduct Guide. UL 1077 DIN Rail Supplementary Protectors
Product Guide UL 0 DIN Rail Supplementary Protectors UL 0 DIN Rail Supplementary Protectors Product Overview... Product Selection WMZS B Curve ( X I n Current Rating)..............................................
More informationK1F003MCH cam ammeter switch - 3 circuits A - for Ø 22 mm
Product data sheet Characteristics cam ammeter switch - 3 circuits - 90-12 A - for Ø 22 mm Complementary Main Range of product Product or component type Component name [Ith] conventional free air thermal
More informationTeSys D contactors. Selection guide. All types of control system. Rated operational voltage. Rated operational power in AC-3. Auxiliary contacts
Selection guide TeSys D contactors Applications All types of control system Rated operational current le max AC- (Ue y 0 V) 9 A A A A A A le AC- (q y 0 C) 0/ A / A /0 A 0 A Rated operational voltage 90
More informationSurge Protection Devices Type 1+2
Surge Protection Devices Type 1+2 Description The combined surge protection devices offer as an all-in-one solution lightning and surge-voltage in one device. They are in accordance with the requirement
More informationLow voltage. NG to 160 A. Modular incoming circuit breakers and switch-disconnectors for DIN-panel installation.
Low voltage NG160 16 to 160 A Modular incoming circuit breakers and switch-disconnectors for DIN-panel installation Catalogue 2010 NG160 circuit breaker Ready to install NG160 General contents Presentation
More informationSolid State Remote Power Controller E
Description The E-T-A is a transistorised switching device providing both protection and signalisation. It is suitable for all applications where the capabilities of the existing PLC s are not sufficient
More informationDISCONNECT SWITCHES > QUICK REFERENCE GUIDE north american edition
DISCONNECT SWITCHES > QUICK REFERENCE GUIDE north american edition OUR COMMITMENT MAKES THE DIFFERENCE > GUARANTEE, CONFORMITY OF LONG-LASTING PRODUCTS BACO facilitates the daily work offering ingenious
More informationMiniature Circuit Breakers for Railway Applications
Siemens AG 00 for Railway Applications BETA Low-Voltage Circuit Protection The miniature circuit breakers are used in fixed railway systems and rolling stock for protecting system components against overcurrent
More informationMotor-protective circuit-breaker, 3p, Ir=16-25A, screw connection. Product range PKZM4 motor protective circuit-breakers up to 65 A
DATASHEET - PKZM4-25 Delivery program Motor-protective circuit-breaker, 3p, Ir=16-25A, screw connection Part no. PKZM4-25 Catalog No. 222352 Eaton Catalog No. XTPR025DC1NL EL-Nummer 0004355158 (Norway)
More informationControl relays. K mini-control relays. Conforming to standards IEC/EN , , NF C , VDE 0660 UL, CSA, DEMKO, NEMKO, SEMKO
Characteristics Environment Conforming to standards IEC/EN 0947-1, 0947-5-1, NF C 3-140, VDE 00 Approvals UL, CSA, DEMKO, NEMKO, SEMKO Vertical axis Horizontal axis Operating position 180 Without derating
More informationApplication Techniques CENTERLINE 2100 Motor Control Centers
POWER SYSTEM CONSIDERATIONS FOR PRODUCT SELECTION Application Techniques CENTERLINE 2100 Motor Control Centers Power System Considerations for Product Selection i Power System Considerations for Product