The Quality Connection. LEONI Datacom Solutions Data Center

Size: px
Start display at page:

Download "The Quality Connection. LEONI Datacom Solutions Data Center"

Transcription

1 The Quality Connection LEONI Datacom Solutions Data Center

2 Infrastructure & Datacom LEONI is a global supplier of cabling systems and services for applications in the automotive business and other industries. In its new Infrastructure & Datacom business unit, LEONI brings together the products and the expertise for power and communications networks in public buildings, in structural and civil engineering, in offices and in industry. Investors, integrators, planners, installers and businesses can thus obtain cables, connection technology and complete cabling solutions from a single source. The range includes system solutions based on copper and fiber optic technology as well as halogen-free power cables with and without functional endurance. Innovations in the areas of safety, environmental compatibility and energy efficiency offer enhanced customer benefits. Thanks to on-site consulting services and extensive experience, LEONI is an internationally recognised partner for your projects. You will find detailed information on our website at:

3 3 VarioLine (For copper and fiber optic connection technology) VarioLine stands for data center system components, which can be used in both the copper and fiber optic connection range. The components in this catalogue are support frames for the copper modules MegaLineNet DClink and the fiber optic modules GigaLineNet DClink and GigaLineNet DC MTP /MPO module with the corresponding accessories as well as cable management panels controlled patch cord management. MegaLineNet (Copper connection technology) GigaLineNet (Fiber optic connection technology) MegaLineNet from LEONI is a copper system family for all transmission classes and categories that delivers a sound, future-proof investment. MegaLineNet incorporates the cable technology of the MegaLine patch and data cables as well as the MegaLineNet and VarioKeystone system solutions. MegaLineNet DC provides system components that are specifically designed to meet data center requirements. GigaLineNet is the name given to the range of fiber optic cable products that allow extremely high bandwidths and long transmission distances. The range is made up of the GigaLine fiber optic cables and the GigaLineNet system technology. The GigaLineNet DC system components are specifically adapted to data center requirements. 4 Generic cabling in data centers 6 Benefits 7 Standards 8 VarioLine Copper and fiber optic connection range 8 VarioLine Consolidation points 9 VarioLine Cable management panels 10 VarioLine Frames and accessories 12 MegaLineNet DC Copper cabling systems 13 MegaLineNet DClink Links for data centers 14 ParaLink CX4 and InfiniBand patch cords 16 MegaLineNet Patch cords 17 GigaLineNet DC Fiber optic systems 18 GigaLineNet DClink Links for data centers 21 GigaLineNet DCflex Fiber optic connection technology 22 GigaLineNet DCflex Distributor housing 23 GigaLineNet DCflex Partial front panels/back panels 24 GigaLineNet DCflex Trunks 25 GigaLineNet MiniZip patch cords 26 GigaLineNet Uniboot patch cords 27 GigaLineNet Smart Box 28 Structure of generic communications cabling 30 Ordering information 31 Services

4 4 Problems in data centers Generic cabling in data centers Reducing costs Multi-cable solutions The heart of every business The data center is frequently referred to as the heart of a business, as it is from here that production and administration processes are controlled. Failures lead to catastrophic consequences that can threaten a company s very survival. Availability must be guaranteed virtually 24 hours a day, 365 days a year. Reliability is influenced to a major extent by the cabling. Single cables laid-worn out-forgotten Not only is the laying of new cables difficult and time-consuming, but it is also virtually impossible to remove old cables, with the result that they often end up simply being cut out or left in place. This means that there is no possibility of reuse or recovery. An unobstructed flow of cooling air is out of the question in this case. Only a higher volumetric flow rate and/or a lower air temperature both of which involve additional costs and environmental impact can help here. Wide range of requirements Enormous energy requirements, greater environmental impact and rising energy prices are pushing ecological issues along with conformity to standards to the fore. The wide range of requirements to be met means that data centers must fulfil the following criteria: High availability (zero downtime) through maximum reliability Short installation times Outstanding performance Low space requirement high packing density Cost efficiency Environmental compatibility Green IT Reducing costs Requirements cannot be viewed in isolation. For example, ecological optimisation can lead to a reduction in costs, while expensive, industrially prefabricated components reduce installation and testing times and thus cut costs incurred as a result of downtime. Multi-cable laid-used-reused Pre-assembled multi-cable solutions produce a clean, clear cabling layout, which not only contributes to simpler, faster cabling but also improves cooling air circulation. The cables and components used are also RoHS-compliant. A small number of multi-cables laid quickly and cleanly guarantee an unobstructed flow of cooling air.

5 VarioLine CP Solutions for data centers 5 The solution Installation Fast high-quality cost-optimised LEONI has demonstrated forward thinking by developing products that go way beyond the current standards and requirements for data centers. The EC7 connector and corresponding cable reach a performance level beyond that of the F A class. Our fiber optic solutions guarantee systems with enormous attenuation and bandwidth reserves. Installation The link modules are simply inserted and clicked into place from the rear after the links are laid. As easy as This system can be used to create fiber optic, copper or mixed configurations in various categories. There is no need for on-site assembly. The modules can be removed using a basic extracting tool. The Plug and Play solution for copper and fiber optic applications from LEONI consists of pre-assembled links and the VarioLine DClink frame (19", 1 RU) for the DClink modules. GigaLineNet DClink MegaLineNet DClink GigaLineNet DCflex

6 6 Benefits for your data center Benefits Reducing costs Optimising attenuation GigaLineNet DClink offers cost savings of up to 55% compared with conventional modular systems using MPO connection technology. A GigaLineNet DClink offers up to 70% less attenuation than conventional modular systems using MPO connection technology. Costs per link* 100% Attenuation per link* I L =1.4 db 100% Modular solutions with MPO 45% DClink Modular solutions with MPO I L =0.4 db >30% DClink * Example: Link length: 30 m, fibers: 24xOS2e, connector: LC duplex * Example: Link length: 30 m, fibers: 24xOS2e, connector: LC duplex Minimising downtime Installation and commissioning take no time at all and there is no need for special tools or knowledge of assembly techniques. This reduces downtime to a minimum. High quality Product quality is factory-tested, with performance and safety built in. Ecologically sound cabling Environmentally sound materials and production methods, the possibility of recycling or ecologically viable recovery and, last but not least, the reusability of products if required guarantee maximum environmental compatibility. Cables and components from LEONI are RoHS-compliant.

7 Standards 7 Standards Standards The structure Generic communications cabling systems are defined in standards EN and ISO/IEC In addition, specific requirements for data centers are defined in EN and ISO/IEC The cabling used in data centers consists of three subsystems: Network access cabling Main distribution cabling Zone distribution cabling Fiber types When using MM fibers, the requirements of class OF-300, using OM3 fibers, must be met as a minimum. Single-mode fibers must comply with category OS1 or OS2, whereby OS1 fibers do not meet the attenuation requirements in each case. The max. extension is 2,000 m. In data centers the main distribution cabling is frequently designed using fiber optic technology, while in smaller networks the external network interface (ENI) is connected directly to the zone distributor (ZD). The standards describe various models for flexible and fixed connections in and between the subsystems. The cabling of the main and zone distribution must, according to ISO/IEC 24764, meet the requirements of class E A for copper technology and transmission classes OF-300, OF-500 and OF-2000 for fiber optic technology as a minimum. Structure of the generic communications cabling system Standards-compliant connection technology in data centers Cu technology: RJ45, GG45 TM and Tera TM Fiber optic cable connectors: LC for 1 or 2 and MPO for more than 2 fibers, GG45 TM and Tera TM ENI Network access cabling MD ZD LDP EO EQP Main distribution cabling Zone distribution cabling Equipment cabling ENI: MD: ZD: LDP: EO: EQP: External network interface Main distributor Zone distributor Local distribution point (optional) External network interface Transmission equipment

8 8 VarioLine DC VarioLine Consolidation points (CPs) VarioLine Consolidation points In office cabling (EN ), consolidation points (CPs) between floor distributor (FD) and telecommunication outlet (TO) offer extremely flexible solutions for rapidly changing office configurations. The CP can be installed in raised floors, inserted ceilings, columns or ducts. From there, flexible cables (CP cables) lead to the data outlets at the workplace. housings. The easy snap-in installation of the housing cover on the floor or zone distributor side makes troublesome screwing and the use of special tools unnecessary. The patch side is covered by a hinged cover with a strip bush as dust protection. The incoming cables and the CP/patch cords can be held by cable ties. The housing can be earthed if necessary. In data centers, CPs as local distribution points (LDP) can provide an additional patching option between zone distributor (ZD) and equipment outlet (EO) (EN ). The CPs are connected to the EO using flexible pre-assembled cables fitted with jacks and connectors, known as consolidation point cables. The CP cables pass through the raised floor via the necessary floor outlets which are installed in the base plate. VarioLine CP floor outlets can be closed flush with the floor when they are not required and are set upright to pass cables through. The cover then also protects the cables as they come out. The robust VarioLine CPs are made of zinc-plated sheet steel and are available in three sizes for 6, 12 and 24 channels. The modular structure ensures that most Cu and FO systems are suitable for universal use. Different module panels for the copper and FO connection systems from LEONI are available for VarioLine CP

9 VarioLine DC 9 Cable management panels VarioLine DC CMP VarioLine DC CMP1 Cable management panel 19", 1 RU with 82 mm metal clips VarioLine DC CMP2 Cable management panel 19", 1 RU with 115 mm metal clips VarioLine DC CMP3 Cable management panel 19" 1 RU with 78 mm plastic clips For the secure installation of FO and Cu patch cords in the distribution cabinet. For the secure installation of FO and Cu patch cords in the distribution cabinet. For the secure installation of FO and Cu patch cords in the distribution cabinet. Panel: sheet steel, powder-coated and black RAL 9005 Clips: metal, 82 mm Dimensions (W x H x D): 483 mm x 44 mm x 95 mm Panel: sheet steel, powder-coated Clips: metal, 115 mm Dimensions (W x H x D): 483 mm x 44 mm x 127 mm Panel: sheet steel, powder-coated Clips: plastic, 78 mm Dimensions (W x H x D): 483 mm x 44 mm x 90 mm Colour: Colour: Colour: black RAL ZE30050 light grey RAL A light grey RAL A light grey RAL ZE10006

10 10 VarioLine DC Frames and accessories VarioLine DClink VarioLine DClink frame, 19", 1 RU VarioLine DClink dummy cover For the simple, fast and secure installation of pre-assembled link segments in data centers. Supports max. 3 link segments Can be equipped with: FLine DClink and/or ELine DClink segments Housing: sheet steel, 2 mm, powder-coated Dimensions (W x H x D): 483 mm x 44 mm x 43 mm VarioLine link dummy cover for closing a segment opening of a VarioLine link frame Housing: sheet steel Dimensions: (W x H x D): 133 mm x 42 mm x 39 mm Designation: Designation: VarioLine frame, 19", 1 RU 9R VarioLine dummy cover 9R Pcs. per packing unit: 8 Pcs. per packing unit: 8

11 VarioLine DC 11 Accessories VarioLine DClink VarioLine DClink Support for two six-way jacks VarioLine DClink six-way jack dummy VarioLine DClink removing tool For mounting two six-way jacks in a VarioLine DClink frame Dummy for adding when using just one six-way jack in a DClink frame Removing tool tool for releasing link segments from VarioLine DClink frames Housing: sheet steel Dimensions (W x H x D): 133 mm x 42 mm x 45 mm Housing: sheet steel Dimensions (W x H x D): 115 mm x 16 mm x 56 mm Material: stainless steel Dimensions (W x H x D): 65 mm x 40 mm x 4 mm Colour: Material: Material: light grey RAL R Sheet steel 9R Stainless steel 9R Pcs. per packing unit: 2 (1 pair)

12 MegaLineNet DC (Copper connection technology)

13 MegaLineNet DC 13 MegaLineNet DClink MegaLineNet DClink 40/100 GigaBit Ethernet with ELine 1200 EC7 six-way jacks MegaLineNet DCink 10 GigaBit Ethernet with ELine 500 plus RJ45 six-way jacks Fully pre-assembled link consisting of a high-quality multi-cable, with a high tensile strength ELine 1200 EC7 six-way jack connection at both ends. Fully pre-assembled link consisting of a high-quality multi-cable, with a high tensile strength ELine 500 plus RJ45 six-way jack connection at both ends. in data centers and in structured in-house cabling systems to ISO/IEC and EN (2nd edition). Suitable for all applications in classes D to F A, multimedia (video, data etc.) >10 GbE to IEEE 802.3an, cable sharing, VoIP, PoE, PoE+. in data centers and in structured in-house cabling systems to ISO/IEC and EN (2nd edition). Suitable for all applications in classes D to E A up to 10 GbE to IEEE 802.3an, VoIP, PoE, PoE+. MegaLine F S/F Multi 6x (4x2xAWG 23/1 PIMF), Cat. 7 A (7KS70186)* Tensile strength: 650 N Flame-retardant and halogen-free outer sheath Sheath diameter: approx mm MegaLine F S/F Multi 6x (4x2xAWG 23/1 PIMF), Cat. 7 A (7KS70186)* Tensile strength: 650 N Flame-retardant and halogen-free outer sheath Sheath diameter: approx mm Link six-way jacks: 6 ELine 1200 EC7 jacks For multimedia applications up to 1.5 GHz Better than Cat. 7 A to ISO/IEC 11801, amendment 1/2 and EN 50173, 2nd edition, amendment 1/2 (draft) Housing: sheet steel Dimensions (W x H x D): 115 mm x 16 mm x 56 mm Link six-way jacks: 6 ELine 500 plus RJ45 jacks Cat. 6 A to ISO/IEC 11801, amendment 1/2 and EN 50173, 2nd edition, amendment 1/2 (draft) Housing: sheet steel Dimensions (W x H x D): 115 mm x 16 mm x 56 mm Packing unit: 1 fully pre-assembled link 9R400xxx (xxx = Length in dm) Packing unit: 1 fully pre-assembled link 9R500xxx (xxx = Length in dm) * Other multi-cable and flex-cable designs on request * Other multi-cable and flex-cable designs on request

14 14 MegaLineNet DC ParaLink High-speed connections LEONI ParaLink cables To meet the extensive requirements for fast point-to-point data transmission applications in modern data centers, LEONI offers fully pre-assembled high-speed cables that exceed the requirements of the IEEE Type 10GBase-CX4 standard and of the IBTA (InfiniBand Trade Association) standard. Compared with conventional CX4 and InfiniBand cable solutions, LEONI patch chords offer improved electromagnetic compatibility, which is achieved using special dual screening. This technology ensures interference-free and complete data transmission across the entire transmission path, right up as far as the connector. Thanks to the use of high-quality LEONI ParaLink cables, the systems have typically low attenuation characteristics at transmission distances of up to 17 m (10GBase-CX4) and a data transmission rate of 10 Gb/s per channel. CX4 patch cords LEONI CX4 and InfiniBand patch cords are manufactured semiautomatically. Manual production has been reduced in order to achieve a high level of uniformity in the manufacturing process. EDS patch cords can be used in data centers for cabling switches, routers and servers in Storage Area Networks (SAN) or High Performance Computing (HPC), as well as in mobile phone base stations.

15 MegaLineNet DC 15 Patch cords ParaLink LEONI 10GBase-CX4 patch cord LEONI InfiniBand patch cord Fully pre-assembled link consisting of a high-quality ParaLink high-speed cable with parallel pairs (twinaxial), assembled with a CX4 connector at both ends. Integrated strain relief, min. 250 N, from the cable via the connector. Fully pre-assembled link consisting of a high-quality ParaLink high-speed cable with parallel pairs (twinaxial), assembled with a CX4 connector at both ends. Integrated strain relief, min. 250 N, from the cable via the connector. In data centers for SAN or HPC and in mobile phone base stations. 8-pair (4X) ParaLink high density cable with LEONIZELL dielectric, small outer diameter and small bending radii Flame-retardant PVC or halogen-free outer sheath Sheath diameter: 5.1 to 9.3 mm (for AWG 32 24) Length dependent on core cross section: 0.5 m to 2 m: AWG 30 3 m to 5 m: AWG 28 6 m to 12 m: AWG m to 15 m: AWG 24 CX4 connector: Housing: die-cast zinc, nickel-plated Dimensions (W x H x D): 25 mm x mm x mm In data centers for SAN or HPC and in mobile phone base stations. Single Data Rates (SDR up to 2.5 Gb/s per channel) and Double Data Rates (DDR up to 5 Gb/s per channel). 8-pair (4X) ParaLink high density cable with LEONIZELL dielectric, small outer diameter and small bending radii. Flame-retardant PVC or halogen-free outer sheath Sheath diameter: 5.1 to 9.3 mm (for AWG 32 24) Length dependent on core cross section: 0.5 m to 3 m: AWG 30 4 m to 5 m: AWG 28 6 m to 8 m: AWG 26 9 m to 12 m: AWG 24 CX4 connector: Housing: die-cast zinc, nickel-plated Dimensions (W x H x D): 25 mm x mm x mm Designation: InfiniBand patch cord: 10GBase-CX4 patch cords 9R8CXxxx For SDR transmission 9R8SDxxx For DDR transmission 9R8DDxxx xxx = Length in dm xxx = Length in dm

16 16 MegaLineNet DC Patch cords MegaLineNet ELine 1200 EC7 patch cord 40/100 GigaBit Ethernet ELine 1200 EC7 patch cord 10 GigaBit Ethernet Patch cord RJ45/RJ MHz Fast/GigaBit Ethernet Pre-assembled with an EC7 connector at both ends Allocation: 1:1 Anti-kink protecting sleeve colour: yellow Pre-assembled with an EC7 connector at both ends Allocation: 1:1 Anti-kink protecting sleeve colour: yellow Pre-assembled with an RJ45 connector at both ends, shielded Allocation: 1:1 Anti-kink protecting sleeve colour: red IEEE 802.3; 10 BASE-T; 100BASE-T; 1000BASE-T; 10GBASE-T compliant; IEEE MB; ISDN; FDDI; ATM, multimedia (video, data, voice), VoIP, PoE, PoE+. IEEE 802.3; 10BASE-T; 100BASE-T; 1000BASE-T; 10GBASE-T compliant; IEEE MB; ISDN; FDDI; ATM, multimedia (video, data, voice), VoIP, PoE, PoE+. IEEE 802.3; 10BASE-T; 100BASE-T; 1000BASE-T; 10GBASE-T compliant IEEE MB; ISDN; FDDI; ATM, VoIP, PoE. Cable used: MegaLine F S/F flex 4x2xAWG 26/7 PIMF Cat. 7 A Flame-retardant and halogen-free outer sheath Colour: grey Connector: ELine 1200 EC7 Cable used: MegaLine F6-90 S/F flex 4x2xAWG 27/7 PIMF Cat. 7 Flame-retardant and halogen-free outer sheath Colour: grey Connector: ELine 1200 EC7 Cable used: MegaLine F6-90 S/F flex 4x2xAWG 27/7 PIMF Cat. 7 Flame-retardant and halogen-free outer sheath Colour: grey RJ45 connector: Hirose TM21 Length: Length: Length: 9KEO m 9KEC m 9A m 9KEO m 9KEC m 9A m 9KEO m 9KEC m 9A m 9KEO m 9KEC m 9A m Other lengths on request Other lengths on request Other lengths on request

17 GigaLineNet DC (Fiber optic connection technology) Product composition GigaLineNet DC

18 18 GigaLineNet DC GigaLineNet DClink GigaLineNet DClink OS2 Fully pre-assembled link consisting of a high-quality universal cable, with a high tensile strength DClink module connection at both ends. GigaLineNet DClink OM4 Fully pre-assembled fiber optic link consisting of a high-quality universal cable, with a high tensile strength DClink module connection at both ends. In data centers and in structured in-house cabling systems to ISO/IEC and EN (2nd edition). Suitable for all applications up to class OF GigaLine DQ 100U OS2 KL-U-DQ(ZN)BH 1x12 or 24 E9/ F3.5/0.22H18 (ITU G652.D) Tensile strength: 1750 N Flame-retardant and halogen-free outer sheath Sheath diameter: approx. 7 or 7.5 mm Link module: Housing: sheet steel Dimensions: 135 mm x 40 mm x 150 mm Equipped with max. 12 LC duplex, 6 SC duplex, 12 SC simplex, 12 E2000 simplex. Insertion loss: typ. 0.2 db Return loss: >40 db (PC), >70 db (APC) In data centers and in structured in-house cabling systems to ISO/ IEC and EN (2nd edition). Suitable for all applications in classes >OF-300 (FLine 550), (10 GBE), OF-500 (GBE/Fiber Channel) and OF-2000 (Fast Ethernet). GigaLine DQ 500U OM4 KL-U-DQ(ZN)BH 1x12 or 24 G50/ B F500 (IEC A1a.3) Laser bandwidth: 4700 MHz x km Tensile strength: 1750 N Flame-retardant and halogen-free outer sheath Sheath diameter: approx. 7 or 7.5 mm Link module: Housing: sheet steel Dimensions: 135 mm x 40 mm x 150 mm Equipped with fiber optic cable connectors (see table) Insertion loss: typ. 0.2 db Return loss: >35 db 6 LC duplex PC 6 LC duplex PC 9R201xxx 6 LC duplex PC 6 SC duplex PC 9R202xxx 6 SC duplex PC 6 SC duplex PC 9R203xxx 12 LC duplex PC 12 LC duplex PC 9R204xxx 12 E2000 simplex PC 12 E2000 simplex PC 9R205xxx 6 LC duplex PC 12 E2000 simplex PC 9R206xxx 6 LC duplex PC 6 LC duplex PC 9R101xxx 6 LC duplex PC 6 SC duplex PC 9R102xxx 6 SC duplex PC 6 SC duplex PC 9R103xxx 12 LC duplex PC 12 LC duplex PC 9R104xxx 12 E2000 simplex PC 12 E2000 simplex PC 9R105xxx 6 LC duplex PC 12 E2000 simplex PC 9R106xxx Other configurations on request, xxx = Length between the link modules in m. Other configurations on request, xxx = Length between the link modules in m.

19 GigaLineNet DC 19 GigaLineNet DClink GigaLineNet DClink OM3 Fully pre-assembled fiber optic link consisting of a high-quality universal cable, with a high tensile strength DClink module connection at both ends. In data centers and in in-house cabling systems to ISO/IEC and EN (2nd edition). Suitable for all applications in classes OF-300 (10 GBE), OF-500 (GBE/Fiber Channel) and OF-2000 (Fast Ethernet). GigaLine DQ 500U OM3 KL-U-DQ(ZN)BH 1x12 or 24 G50/ B F500 (IEC A1a.2) Laser bandwidth: 2000 MHz x km Tensile strength: 1750 N Flame-retardant and halogen-free outer sheath Sheath diameter: approx. 7 or 7.5 mm Link module: Housing: sheet steel Dimensions: 135 mm x 40 mm x 150 mm Equipped with fiber optic cable connectors (see table) Insertion loss: typ. 0.2 db Return loss: >35 db GigaLineNet DClink MTP /MPO module OS2, OM3, OM4 Fully pre-assembled MTP /MPO module for installation in a DClink frame. In data centers and in in-house cabling systems to ISO/IEC and EN (2nd edition). Suitable for all applications in classes > OF-300 (FLine 550), (10 GBE), OF-500 (GBE/Fiber Channel) and OF-2000 (Fast Ethernet). DC module: Housing: sheet steel Dimensions: 135 mm x 40 mm x 150 mm Front equipped with max. 12 LC duplex, 6 SC duplex, 12 SC simplex, 12 E2000 simplex. Insertion loss: typ. 0.2 db Return loss: >40 db (SM, PC), >70 db (SM, APC), >35 db (MM) Rear equipped with 1x or 2x MTP /MPO Insertion loss: typ. 0.3 db Return loss: >55 db (SM) >20 db (MM) Fiber types: OS2, OM4, OM3 6 LC duplex PC - 6 LC duplex PC 9R301xxx 6 LC duplex PC - 6 SC duplex PC 9R302xxx 6 SC duplex PC - 6 SC duplex PC 9R303xxx 12 LC duplex PC - 12 LC duplex PC 9R304xxx 12 E2000 simplex PC - 12 E2000 simplex PC 9R305xxx 6 LC duplex PC - 12 E2000 simplex PC 9R306xxx 6 LC duplex PC - 1 MTP /MPO (OS2) 9R LC duplex PC - 2 MTP /MPO (OS2) 9R LC duplex PC - 1 MTP /MPO (OM4) 9R LC duplex PC - 2 MTP /MPO (OM4) 9R LC duplex PC - 1 MTP /MPO (OM3) 9R LC duplex PC - 2 MTP /MPO (OM3) 9R Other configurations on request. xxx = Length between the link modules in m.

20 20 GigaLineNet DC Trunks GigaLineNet DClink GigaLineNet DClink MTP /MPO trunk 12 and 24 OS2 Fully pre-assembled MTP /MPO trunk with one or two MTP /MPO connectors at one or both ends. GigaLineNet DClink MTP /MPO trunk 12 and 24 OM4 Fully pre-assembled MTP /MPO trunk with one or two MTP /MPO connectors at one or both ends. GigaLineNet DClink MTP /MPO trunk 12 and 24 OM3 Fully pre-assembled MTP /MPO trunk with one or two MTP /MPO connectors at one or both ends. Installation in data centers and in structured in-house cabling systems to ISO/IEC and EN (2nd edition). Suitable for all applications up to class OF GigaLine I-F(ZN)H 1x12 or I-F(ZN) HH 2x12 E9/ F H18 OS2 (ITU G652.D) Tensile strength: 400 N (1x12) N (2x12) Flame-retardant and halogen-free outer sheath Colour: yellow Sheath diameter: 3 mm (1x12), 8.9 mm (2x12) Connector: Connector: MTP /MPO (US Conec) Standard: IEC Colour coding: green Insertion loss: typ db Return loss: >55 db (SM APC) Installation in data centers and in structured in-house cabling systems to ISO/IEC and EN (2nd edition). Suitable for all applications in classes >OF-300 (FLine 550, 10 GBE), OF-500 (GBE/Fiber Channel) and OF-2000 (Fast Ethernet). GigaLine I-F(ZN)H 1x12 or I-F(ZN)HH 2x12G50/ B F500 OM4 (IEC A1a.3) Laser bandwidth: 4700 MHz x km Tensile strength: 400 N (1x12), 800 N (2x12) Flame-retardant and halogen-free outer sheath Colour: magenta Sheath diameter: 3 mm (1x12) 8.9 mm (2X12) Connector: MTP /MPO (US Conec) Standard: IEC Colour coding: aqua Insertion loss: typ db Return loss: >20 db (MM) Installation in data centers and in structured in-house cabling systems to ISO/IEC and EN (2nd edition). Suitable for all applications in classes OF-300 (10 GBE), OF-500 (GBE/Fiber Channel) and OF-2000 (Fast Ethernet). GigaLine I-F(ZN)H 1x12 or I-F(ZN)HH 2x12 G50/ B F500 OM3 (IEC A1a.2) Laser bandwidth: 2000 MHz x km Tensile strength: 400 N (1x12), 800 N (2x12) Flame-retardant and halogen-free outer sheath Colour: aqua Sheath diameter: 3 mm (1x12) 8.9 mm (2X12) Connector: MTP /MPO (US Conec) Standard: IEC Colour coding: aqua Insertion loss: typ db Return loss: >20 db (MM) 1 MTP /MPO - 1 MTP /MPO OS2 9R711xxx 2 MTP /MPO - 2 MTP /MPO OS2 9R712xxx 1 MTP /MPO - 1 MTP /MPO OM4 9R713xxx 2 MTP /MPO - 2 MTP /MPO OM4 9R714xxx 1 MTP /MPO - 1 MTP /MPO OM3 9R715xxx 2 MTP /MPO - 2 MTP /MPO OM3 9R716xxx xxx = Length in m. xxx = Length in m. xxx = Length in m.

21 GigaLineNet DCflex (Fiber optic connection technology)

22 22 GigaLineNet DC Distributor housing GigaLineNet DCflex GigaLineNet DCflex box, 19", 1 RU, fixed Box for the flexible installation of preassembled fiber optic cables (trunks). Rear can be equipped with 1 RU back panel, dummy, or back panel for 12 trunks or back panel for 8 M25 cable glands GigaLineNet DCflex box, 19", 2 RU, fixed Box for the flexible installation of preassembled fiber optic cables (trunks). Rear can be equipped with 1 RU back panel, dummy, or back panel for 12 trunks or back panel for 8 M25 cable glands GigaLineNet DCflex box, 19", 3 RU, fixed Box for the flexible installation of preassembled fiber optic cables (trunks). Rear can be equipped with 1 RU back panel, dummy, or back panel for 12 trunks or back panel for 8 M25 cable glands For use in data centers for holding partition front panels with fiber optic adapters or dummy panels. (2 x TFP2 or 3 x TFP3, TFP not included in scope of delivery) For use in data centers for holding partition front panels with fiber optic adapters or dummy panels. (2 x TFP2 or 3 x TFP3, TFP not included in scope of delivery) For use in data centers for holding partition front panels with fiber optic adapters or dummy panels. (2 x TFP2 or 3 x TFP3, TFP not included in scope of delivery) Housing: aluminium Front: sheet steel, powder-coated Dimensions: 483 mm x 44 mm x 300 mm Housing: aluminium Front: sheet steel, powder-coated Dimensions: 483 mm x 88 mm x 300 mm Housing: aluminium Front: sheet steel, powder-coated Dimensions: 483 mm x 132 mm x 300 mm Box, 1 RU 9RA00001 Box, 2 RU 9RA00002 Box, 3 RU 9RA00003

23 GigaLineNet DC 23 Front panels and back panels GigaLineNet DCflex GigaLineNet DCflex TFP2, partial front panel ¹/2 x 19", 1 RU for distribution box Partial front panel for the flexible configuration of boxes in 1, 2 and 3 RU. GigaLineNet DCflex TFP3, partial front panel ¹/3 x 19", 1 RU for distribution box Partial front panel for the flexible configuration of boxes in 1, 2 and 3 RU. GigaLineNet DCflex BP, back panel, 1 RU for distribution box Back panel for the configuration of boxes in 1, 2 and 3 RU. Material: sheet steel, powder-coated Dimensions: 208 mm x 41 mm TFP2 are available in different configurations (see below). TFP2 dummy 9RA00020 TFP2-12LC-Dx MM 9RA00021 TFP2-12LC-Dx SM/PC 9RA00022 TFP2-12LC-Dx SM/APC 9RA00023 TFP2-12SC-Dx MM 9RA00024 TFP2-12SC-Dx SM/PC 9RA00025 TFP2-12SC-Dx SM/APC 9RA00026 TFP2-8MU-4C MM 9RA00027 TFP2-16LC-Dx MM 9RA00028 Material: sheet steel, powder-coated Dimensions: 139 mm x 41 mm TFP3 are available in different configurations (see below). TFP3 dummy 9RA00030 TFP3-8LC-Dx MM 9RA00031 TFP3-8LC-Dx SM/PC 9RA00032 TFP3-8LC-Dx SM/APC 9RA00033 TFP3-8SC-Dx MM 9RA00034 TFP3-8SC-Dx SM/PC 9RA00035 TFP3-8SC-Dx SM/APC 9RA00036 TFP3-4MU-4C MM 9RA00037 BP are available as dummy panels, as cable management panels for 12 trunks and for eight M25 cable glands for routing breakout cables. Material: sheet steel, zinc-plated Dimensions: 442 mm x 44 mm BP are available in different configurations (see below). BP dummy 9RA00010 BP-12 9RA00011 BP-8 9RA00012 Other configurations on request Other configurations on request Other configurations on request

24 24 GigaLineNet DC Trunks GigaLineNet DCflex GigaLineNet DCflex trunk OS2 Fully pre-assembled fiber optic trunk, with a divider and fiber optic connectors at one or both ends. GigaLineNet DCflex trunk OM4 Fully pre-assembled fiber optic trunk, with a divider and fiber optic connectors at one or both ends. GigaLineNet DCflex trunk OM3 Fully pre-assembled fiber optic trunk, with a divider and fiber optic connectors at one or both ends. Installation in data centers and in structured in-house cabling systems to ISO/IEC and EN (2nd edition). Suitable for all applications up to class OF Pigtail length: stepped, 45 cm to 75 cm Connector protector: fabric tube Installation in data centers and in structured in-house cabling systems to ISO/IEC and EN (2nd edition). Suitable for all applications up to class OF-300 (10GBE). Pigtail length: stepped, 45 cm to 75 cm Connector protector: fabric tube Installation in data centers and in structured in-house cabling systems to ISO/IEC and EN (2nd edition). Suitable for all applications up to class OF-300 (10GBE). Pigtail length: stepped, 45 cm to 75 cm Connector protector: fabric tube GigaLine DQ 100 U OS2 KL-U-DQ(ZN) BH 1x12 or 1x24 E9/ F3.5/0.22H18 (ITU G652.D) Tensile strength: 1750 N Flame-retardant and halogen-free outer sheath Sheath diameter: approx. 7 or 7.5 mm Divider: aluminium, diameter 25/33 mm with slot for insertion in FLine and VKT housing Assembly: LC duplex, SC duplex, SC simplex, E2000 simplex Insertion loss: typ. 0.2 db Return loss: >40 db (PC), >70 db (APC) GigaLine DQ 500 U OM4 KL-U-DQ(ZN)BH 1x12 or 1x24 G50/ B F500 (ITU G651) Laser bandwidth: 4700 MHz x km Tensile strength: 1750 N Flame-retardant and halogen-free outer sheath Sheath diameter: approx. 7 or 7.5 mm Divider: aluminium, diameter 25/33 mm with slot for insertion in FLine and VKT housing. Assembly: LC duplex, SC duplex, SC simplex, E2000 simplex Insertion loss: typ. 0.2 db Return loss: >35 db GigaLine DQ 500 U OM3 KL-U-DQ(ZN)BH 1x12 or 1x24 G50/ B F500 (ITU G651) Laser bandwidth: 1500 MHz x km Tensile strength: 1750 N Flame-retardant and halogen-free outer sheath Sheath diameter: approx. 7 or 7.5 mm Divider: aluminium, diameter 25/33 mm with slot for insertion in FLine and VKT housing. Assembly: LC duplex, SC duplex, SC simplex, E2000 simplex Insertion loss: typ. 0.2 db Return loss: >35 db 2x 6 LC duplex PC 9RC01xxx 6 LC duplex PC to 6 SC duplex PC 9RC02xxx 2x 6 SC duplex PC 2x 12 LC duplex PC 2x 12 E2000 simplex PC 12 LC duplex PC to 24 E2000 simplex PC 9RC03xxx 9RC04xxx 9RC05xxx 9RC06xxx 2x 6 LC duplex 9RB01xxx 6 LC duplex to 6 SC duplex 9RB02xxx 2x 6 SC duplex 9RB03xxx 2x 12 LC duplex 9RB04xxx 2x 12 E2000 simplex 9RB05xxx 12 LC duplex to 24 E2000 simplex 9RB06xxx 2x 24 LC duplex 9RB07xxx 2x 32 MU duplex 9RB08xxx 2x 6 LC duplex 9RF01xxx 6 LC duplex to 6 SC duplex 9RF02xxx 2x 6 SC duplex 9RF03xxx 2x 12 LC duplex 9RF04xxx 2x 12 E2000 simplex 9RF05xxx 12 LC duplex to 24 E2000 simplex 9RF06xxx 2x 24 LC duplex 9RF07xxx 2x 32 MU duplex 9RF08xxx

25 GigaLineNet DC 25 MiniZip patch cords GigaLineNet GigaLineNet patch cord OS2 LC duplex, SC duplex, SC simplex, E2000 simplex Insertion loss: typ. 0.2 db Return loss: >45 db (PC) >70 db (APC) GigaLineNet patch cord OM4 LC duplex, SC duplex, SC simplex, E2000 simplex, MU Insertion loss: typ. 0.2 db Return loss: >35 db Laser bandwidth: 4700 MHz x km GigaLineNet patch cord OM3 LC duplex, SC duplex, SC simplex, E2000 simplex, MU Insertion loss: typ. 0.2 db Return loss: >35 Laser bandwidth: 2000 MHz x km Two semi-tight buffered fibers in figure 8-form with strain relief. Strain relief elements: aramid Sheath: halogen-free compound Colour of sheath: yellow Two semi-tight buffered fibers in figure 8-form with strain relief. Strain relief elements: aramid Sheath: halogen-free compound Colour of sheath: magenta Two semi-tight buffered fibers in figure 8-form with strain relief. Strain relief elements: aramid Sheath: halogen-free compound Colour of sheath: aqua Temperature range: Transport and storage: 25 C to +70 C Installation: 5 C to +50 C Operation: 10 C to +70 C Temperature range: Transport and storage: 25 C to +70 C Installation: 5 C to +50 C Operation: 10 C to +70 C Temperature range: Transport and storage: 25 C to +70 C Installation: 5 C to +50 C Operation: 10 C to +70 C Bending radius (over flat side): After installation: 30 mm During installation: 60 mm Bending radius (over flat side): After installation: 30 mm During installation: 60 mm Bending radius (over flat side): After installation: 30 mm During installation: 60 mm Fire performance: Flame retardancy: IEC , IEC Smoke density: IEC Halogen-free: IEC Fire performance: Flame retardancy: IEC , IEC Smoke density: IEC Halogen-free: IEC Fire performance: Flame retardancy: IEC , IEC Smoke density: IEC Halogen-free: IEC x LC/PC-Dx-OS2 (2 m) 9A x LC-Dx-OM4 (2 m) 9A x LC-Dx-OM3 (2 m) 9A x LC/APC-Dx-OS2 (2 m) 9A x SC-Dx-OM4 (2 m) 9A x SC-Dx-OM3 (2 m) 9A x SC/PC-Dx-OS2 (2 m) 9A x E2000-Dx-OM4 (2 m) 9A x E2000-Dx-OM3 (2 m) 9A x SC/APC-Dx-OS2 (2 m) 9A x MU-OM4 (2 m) 9A x MU-OM3 (2 m) 9A x E2000/PC-Dx-OS2 (2 m) 9A x E2000/APC-Dx-OS2 (2 m) 9A Other configurations on request Other configurations on request Other configurations on request

26 26 GigaLineNet DC LC Uniboot patch cords GigaLineNet GigaLineNet LC Uniboot patch cord OS2 LC duplex uniboot Insertion loss: <0.4 db Return loss: >35 db (PC) GigaLineNet LC Uniboot patch cord OM4 LC duplex uniboot Insertion loss: <0.4 db Return loss: >35 db (PC) Laser bandwidth: 4700 MHz x km GigaLineNet LC Uniboot patch cord OM3 LC duplex uniboot Insertion loss: <0.4 db Return loss: >35 db (PC) Laser bandwidth: 1500 MHz x km Two semi-tight buffered fibers under a common sheath (round). Cable type: KL-I-V(ZN)H 2G 50/125 Cable diameter: 2.8 mm Strain relief elements: aramid Sheath: halogen-free compound Colour of sheath: yellow Tensile strength: 300 N Two semi-tight buffered fibers under a common sheath (round). Cable type: KL-I-V(ZN)H 2G 50/125 Cable diameter: 2.8 mm Strain relief elements: aramid Sheath: halogen-free compound Colour of sheath: magenta Tensile strength: 300 N Two semi-tight buffered fibers under a common sheath (round). Cable type: KL-I-V(ZN)H 2G 50/125 Cable diameter: 2.8 mm Strain relief elements: aramid Sheath: halogen-free compound Colour of sheath: aqua Tensile strength: 300 N Temperature range: Transport and storage: 25 C to +70 C Installation: 5 C to +50 C Operation: 10 C to +70 C Temperature range: Transport and storage: 25 C to +70 C Installation: 5 C to +50 C Operation: 10 C to +70 C Temperature range: Transport and storage: 25 C to +70 C Installation: 5 C to +50 C Operation: 10 C to +70 C Bending radius: After installation: 30 mm During installation: 60 mm Bending radius: After installation: 30 mm During installation: 60 mm Bending radius: After installation: 30 mm During installation: 60 mm Fire performance: Flame retardancy: IEC , IEC Smoke density: IEC Halogen-free: IEC Fire performance: Flame retardancy: IEC , IEC Smoke density: IEC Halogen-free: IEC Fire performance: Flame retardancy: IEC , IEC Smoke density: IEC Halogen-free: IEC Designation: Designation: Designation: LCDU LCDU OS2 1 m 9A LCDU LCDU OM4 1 m 9A LCDU LCDU OM3 1 m 9A LCDU LCDU OS2 2 m 9A LCDU LCDU OM4 2 m 9A LCDU LCDU OM3 2 m 9A LCDU LCDU OS2 3 m 9A LCDU LCDU OM4 3 m 9A LCDU LCDU OM3 3 m 9A LCDU LCDU OS2 5 m 9A LCDU LCDU OM4 5 m 9A LCDU LCDU OM3 5 m 9A LCDU LCDU OS2 7.5 m 9A LCDU LCDU OM4 7.5 m 9A LCDU LCDU OM3 7.5 m 9A LCDU LCDU OS2 10 m 9A LCDU LCDU OM4 10 m 9A LCDU LCDU OM3 10 m 9A110873

27 GigaLineNet DC 27 Distribution Boxes GigaLineNet GigaLineNet Smart Box, fixed 19", 1 RU, 48 LC duplex For supporting max. 2 trunks Equipped with 48 LC duplex adapters Multi-mode: plastic/phbz, beige Single-mode/PC: plastic/zirconia, blue Single-mode/APC: plastic/zirconia, green Housing made from zinc-plated sheet steel Screen printing inscription 1-48 Dimensions: 483 mm x 1 RU x 98 mm (WxHxD) GigaLineNet Smart Box, telescopic 19", 1 RU, 48 LC duplex For supporting max. 2 trunks Equipped with 48 LC duplex adapters Multimode: plastic/phbz, beige Single-mode/PC: plastic/zirconia, blue Single-mode/APC: plastic/zirconia, green Housing made from zinc-plated sheet steel Screen printing inscription 1-48 Dimensions: 483 mm x 1 RU x 98 mm (WxHxD) Other GigaLineNet Smart Boxes on request Other GigaLineNet Smart Boxes on request Fiber type: Fiber type: MM 9D MM 9D SM/PC On request SM/PC On request SM/APC On request SM/APC On request

28 28 Generic communications cabling Structure of generic communications cabling ENI MD MD Distributor to EN Network access cabling Main distribution cabling

29 Generic communications cabling 29 LDP EO EQP Zone distribution cabling Equipment cabling ENI: MD: ZD: LDP: EO: EQP: External network interface Main distributor Zone distributor Local distribution point (optional) External network interface Transmission equipment

30 30 Index Page Product Art. no. 9 VarioLine DC CMP1, black 9ZE VarioLine DC CMP1, grey 9ZE VarioLine DC CMP2, grey 9A VarioLine DC CMP3, grey 9A VarioLine DClink frame, 19", 1 RU 9R VarioLine DClink dummy cover 9R VarioLine DClink frame for 2 six-way jacks 9R VarioLine DClink six-way jack dummy 9R VarioLine DClink extracting tool 9R MegaLineNet DClink 40/100 GigaBit Ethernet six-way jack 9R400xxx 13 MegaLineNet DClink 10 GigaBit Ethernet six-way jack 9R500xxx 15 LEONI CX4 patch cord 9R8CXxxx 15 LEONI InfiniBand patch cord for SDR transmission 9R8SDxxx 15 LEONI InfiniBand patch cord for DDR transmission 9R8DDxxx 16 ELine 1200 EC7 patch cord 40/100 GBE 1.0 m 9KEO ELine 1200 EC7 patch cord 40/100 GBE 2.0 m 9KEO ELine 1200 EC7 patch cord 40/100 GBE 3.0 m 9KEO ELine 1200 EC7 patch cord 40/100 GBE 5.0 m 9KEO ELine 1200 EC7 patch cord 10GBE 1.0 m 9KEC ELine 1200 EC7 patch cord 10GBE 2.0 m 9KEC ELine 1200 EC7 patch cord 10GBE 3.0 m 9KEC ELine 1200 EC7 patch cord 10GBE 5.0 m 9KEC Patch cord RJ45/RJ MHz shielded 1.0 m 9A Patch cord RJ45/RJ MHz shielded 2.0 m 9A Patch cord RJ45/RJ MHz shielded 3.0 m 9A Patch cord RJ45/RJ MHz shielded 5.0 m 9A GigaLineNet DClink OS2-6 LC duplex PC - 6 LC duplex PC 9R201xxx 18 GigaLineNet DClink OS2-6 LC duplex PC - 6 SC duplex PC 9R202xxx 18 GigaLineNet DClink OS2-6 SC duplex PC - 6 SC duplex PC 9R203xxx 18 GigaLineNet DClink OS2-12 LC duplex PC - 12 LC duplex PC 9R204xxx 18 GigaLineNet DClink OS2-12 E2000 simplex PC - 12 E2000 simplex PC 9R205xxx 18 GigaLineNet DClink OS2-6 LC duplex PC - 12 E2000 simplex PC 9R206xxx 18 GigaLineNet DClink OM4-6 LC duplex PC - 6 LC duplex PC 9R101xxx 18 GigaLineNet DClink OM4-6 LC duplex PC - 6 SC duplex PC 9R102xxx 18 GigaLineNet DClink OM4-6 SC duplex PC - 6 SC duplex PC 9R103xxx 18 GigaLineNet DClink OM4-12 LC duplex PC -12 LC duplex PC 9R104xxx 18 GigaLineNet DClink OM4-12 E2000 simplex PC - 12 E2000 simplex PC 9R105xxx 18 GigaLineNet DClink OM4-6 LC duplex PC - 12 E2000 simplex PC 9R106xxx 19 GigaLineNet DClink OM3-6 LC duplex PC - 6 LC duplex PC 9R301xxx 19 GigaLineNet DClink OM3-6 LC duplex PC - 6 SC duplex PC 9R302xxx 19 GigaLineNet DClink OM3-6 SC duplex PC - 6 SC duplex PC 9R303xxx 19 GigaLineNet DClink OM3-12 LC duplex PC -12 LC duplex PC 9R304xxx 19 GigaLineNet DClink OM3-12 E2000 simplex PC - 12 E2000 simplex PC 9R305xxx 19 GigaLineNet DClink OM3-6 LC duplex PC - 12 E2000 simplex PC 9R306xxx 19 GigaLineNet MTP /MPO module - 6LC duplex PC - 1MTP /MPO OS2 9R GigaLineNet MTP /MPO module - 12LC duplex PC - 2MTP /MPO OS2 9R GigaLineNet MTP /MPO module - 6LC duplex PC - 1MTP /MPO OM4 9R GigaLineNet MTP /MPO module - 12LC duplex PC - 2MTP /MPO OM4 9R GigaLineNet MTP /MPO module - 6LC duplex PC - 1MTP /MPO OM3 9R GigaLineNet MTP /MPO module - 12LC duplex PC - 2MTP /MPO OM3 9R GigaLineNet trunk 1 MTP /MPO - 1 MTP /MPO - 12 OS2 9R711xxx 20 GigaLineNet trunk 2 MTP /MPO - 2 MTP /MPO - 24 OS2 9R712xxx 20 GigaLineNet trunk 1 MTP /MPO - 1 MTP /MPO - 12 OM4 9R713xxx 20 GigaLineNet trunk 2 MTP /MPO - 2 MTP /MPO - 24 OM4 9R714xxx 20 GigaLineNet trunk 1 MTP /MPO - 1 MTP /MPO - 12 OM3 9R715xxx 20 GigaLineNet trunk 2 MTP /MPO - 2 MTP /MPO - 24 OM3 9R716xxx 22 GigaLineNet DCflex - box, 19", 1 RU 9RA GigaLineNet DCflex - box, 19", 2 RU 9RA GigaLineNet DCflex - box, 19", 3 RU 9RA GigaLineNet DCflex-TFP2 dummy 9RA GigaLineNet DCflex - TFP2-12LC-Dx MM 9RA GigaLineNet DCflex - TFP2-12LC-Dx SM/PC 9RA GigaLineNet DCflex - TFP2-12LC-Dx SM/APC 9RA GigaLineNet DCflex - TFP2-12SC-Dx MM 9RA GigaLineNet DCflex - TFP2-12SC-Dx SM/PC 9RA GigaLineNet DCflex - TFP2-12SC-Dx SM/APC 9RA GigaLineNet DCflex - TFP2-8MU-4C MM 9RA GigaLineNet DCflex - TFP2-16LC-Dx MM 9RA00028 Page Product Art. no. 23 GigaLineNet DCflex - TFP3 dummy 9RA GigaLineNet DCflex - TFP3-8LC-Dx MM 9RA GigaLineNet DCflex - TFP3-8LC-Dx SM/PC 9RA GigaLineNet DCflex - TFP3-8LC-Dx SM/APC 9RA GigaLineNet DCflex - TFP3-8SC-Dx MM 9RA GigaLineNet DCflex - TFP3-8SC-Dx SM/PC 9RA GigaLineNet DCflex - TFP3-8SC-Dx SM/APC 9RA GigaLineNet DCflex - TFP3-4 MU-4C MM 9RA GigaLineNet DCflex - BP dummy 9RA GigaLineNet DCflex - BP-12 9RA GigaLineNet DCflex - BP-8 9RA GigaLineNet trunk OS2-6 LC duplex PC - 6 LC duplex PC 9RC01xxx 24 GigaLineNet trunk OS2-6 LC duplex PC - 6 SC duplex PC 9RC02xxx 24 GigaLineNet trunk OS2-6 SC duplex PC - 6 SC duplex PC 9RC03xxx 24 GigaLineNet trunk OS2-12 LC duplex PC -12 LC duplex PC 9RC04xxx 24 GigaLineNet trunk OS2-12 E2000 simplex PC - 12 E2000 simplex PC 9RC05xxx 24 GigaLineNet trunk OS2-12LC duplex PC - 24 E2000 simplex PC 9RC06xxx 24 GigaLineNet trunk OM4-6 LC duplex - 6 LC duplex 9RB01xxx 24 GigaLineNet trunk OM4-6 LC duplex - 6 SC duplex 9RB02xxx 24 GigaLineNet trunk OM4-6 SC duplex - 6 SC duplex 9RB03xxx 24 GigaLineNet trunk OM4-12 LC duplex - 12 LC duplex 9RB04xxx 24 GigaLineNet trunk OM4-12 E2000 simplex - 12 E2000 simplex 9RB05xxx 24 GigaLineNet trunk OM4-12 LC duplex - 24 E2000 simplex 9RB06xxx 24 GigaLineNet trunk OM4-24 LC duplex - 24 LC duplex 9RB07xxx 24 GigaLineNet trunk OM4-32 MU - 32 MU 9RB08xxx 24 GigaLineNet trunk OM3-6 LC duplex - 6 LC duplex 9RF01xxx 24 GigaLineNet trunk OM3-6 LC duplex - 6 SC duplex 9RF02xxx 24 GigaLineNet trunk OM3-6 SC duplex - 6 SC duplex 9RF03xxx 24 GigaLineNet trunk OM3-12 LC duplex - 12 LC duplex 9RF04xxx 24 GigaLineNet trunk OM3-12 E2000 simplex - 12 E2000 simplex 9RF05xxx 24 GigaLineNet trunk OM3-12 LC duplex - 24 E2000 simplex 9RF06xxx 24 GigaLineNet trunk OM3-24 LC duplex - 24 LC duplex 9RF07xxx 24 GigaLineNet trunk OM3-32 MU - 32 MU 9RF08xxx 25 GigaLineNet MiniZip patch cord LC/PC-Dx-LC/PC-Dx-OS2-2 m 9A GigaLineNet MiniZip patch cord LC/APC-Dx-LC/APC-Dx-OS2-2 m 9A GigaLineNet MiniZip patch cord SC/PC-Dx-SC/PC-Dx-OS2-2 m 9A GigaLineNet MiniZip patch cord SC/APC-Dx-SC/APC-Dx-OS2-2 m 9A GigaLineNet MiniZip patch cord E2000/PC-Dx-E2000/PC-Dx-OS2-2 m 9A GigaLineNet MiniZip patch cord E2000/APC-Dx-E2000/APC-Dx-OS2-2 m 9A GigaLineNet MiniZip patch cord LC-Dx-LC-Dx-OM4-2 m 9A GigaLineNet MiniZip patch cord SC-Dx-SC-Dx-OM4-2 m 9A GigaLineNet MiniZip patch cord E2000-Dx-E2000-Dx-OM4-2 m 9A GigaLineNet MiniZip patch cord MU duplex - MU duplex-om4-2 m 9A GigaLineNet MiniZip patch cord LC-Dx-LC-Dx-OM3-2 m 9A GigaLineNet MiniZip patch cord SC-Dx-SC-Dx-OM3-2 m 9A GigaLineNet MiniZip patch cord E2000-Dx-E2000-Dx-OM3-2 m 9A GigaLineNet MiniZip patch cord MU duplex - MU duplex-om3-2 m 9A GigaLineNet LCDU-LCDU OS2-1 m 9A GigaLineNet LCDU-LCDU OS2-2 m 9A GigaLineNet LCDU-LCDU OS2-3 m 9A GigaLineNet LCDU-LCDU OS2-5 m 9A GigaLineNet LCDU-LCDU OS2-7.5 m 9A GigaLineNet LCDU-LCDU OS2-10 m 9A GigaLineNet LCDU-LCDU OM4-1 m 9A GigaLineNet LCDU-LCDU OM4-2 m 9A GigaLineNet LCDU-LCDU OM4-3 m 9A GigaLineNet LCDU-LCDU OM4-5 m 9A GigaLineNet LCDU-LCDU OM4-7.5 m 9A GigaLineNet LCDU-LCDU OM4-10 m 9A GigaLineNet LCDU-LCDU OM3-1 m 9A GigaLineNet LCDU-LCDU OM3-2 m 9A GigaLineNet LCDU-LCDU OM3-3 m 9A GigaLineNet LCDU-LCDU OM3-5 m 9A GigaLineNet LCDU-LCDU OM3-7.5 m 9A GigaLineNet LCDU-LCDU OM3-10 m 9A GigaLineNet Smart Box, fixed, 48 LC duplex, MM 9D GigaLineNet Smart Box, telescopic, 48 LC duplex, MM 9D320151

31 Service 31 Cutting corners with cabling... Active components 7% For the configuration of networks, only 5% of the costs are due to the passive cabling, while the active components account for 7%. Investment in the workstation represents roughly one third of the costs (34%), while the biggest cost driver of all is software at 54%. Workstation 34% Given the fact that passive cabling has a service life of 15 years, one thing is certainly clear: Cutting corners with cabling is a false economy. Cabling 5% Software 54% The following information can be found at: Data sheets and announcement texts Specialist articles Trained Networker certification programme Seminars and roadshows News/standards Planer DVD

32 LEONI Kerpen GmbH Business Unit Infrastructure & Datacom Zweifaller Straße Stolberg Germany Tel.: +49 (0) Fax: +49 (0)

The Quality Connection. LEONI QuickLine Class E Cabling Solution

The Quality Connection. LEONI QuickLine Class E Cabling Solution The Quality Connection LEONI QuickLine Class E Cabling Solution QuickLine 2 Content Infrastructure & Datacom Solutions from a single source Shielded solution, keystone 4 Shielded solution, punch-down 5

More information

Data sheet PM PCC OpDAT patch cord LC-D/LC-D OM3 aqua, 20.0 m

Data sheet PM PCC OpDAT patch cord LC-D/LC-D OM3 aqua, 20.0 m Illustrations Dimensional drawing Page 1/5 See enlarged drawings at the end of document Product specification patch cord for the METZ CONNECT Patch Management System multi mode patch cord I-V(ZN)H 50/125

More information

4Cu-LSA Connection technology

4Cu-LSA Connection technology 4Cu-LSA technology LSA- technology: Patch panels, Telephone Patch Panels, RJ45, Tera, Office-Patch Panels, Data outlets, surface mounting, flush mount, underfloor, 60 Table of Contents Office DC FTTX Patch

More information

Migratable cabling in computer centres for all data rates from Mbit/s to 100Gbit/s (DClink)

Migratable cabling in computer centres for all data rates from Mbit/s to 100Gbit/s (DClink) Introduction Computer centres must be reliable and available around the clock even during conversion work. Data rates are increasing constantly, and the FO cabling which only recently supported all applications

More information

Plug & Play Universal Harness, SMF-28 Ultra Single-mode (OS2)

Plug & Play Universal Harness, SMF-28 Ultra Single-mode (OS2) Plug & Play Universal Systems Harnesses have a pinned (male) MTP connector on one end that connects to a Plug & Play Universal Systems trunk or extender trunk, while the other end is equipped with single

More information

SPEC SHEET. Multimode Patch Cords and Pigtails. Cable types. Description. Features. Fiber types

SPEC SHEET. Multimode Patch Cords and Pigtails. Cable types. Description. Features. Fiber types Multimode Patch Cords and Pigtails SPEC SHEET Description ADC KRONE offers a wide array of multimode fibre optic patch cords featuring Riser and LSZH cables in various diameters. ADC KRONE s multimode

More information

PerCONNECT PRODUCT INFORMATION

PerCONNECT PRODUCT INFORMATION PerCONNECT PRODUCT INFORMATION Contents: Page Applications 3-4 Cable types 5-6 Splice panels 7 Splice units 8 Splice accessories 9 Distribution solution 10-11 MTP Application 12 Accessories 13-15 Racks

More information

Data sheet. 25Gmodul. Illustrations P/N 130B11-25-E EAN Product specification. Page 1/ Dimensional drawing

Data sheet. 25Gmodul. Illustrations P/N 130B11-25-E EAN Product specification. Page 1/ Dimensional drawing Page 1/6 Illustrations Dimensional drawing Cut-out See enlarged drawings at the end of document Product specification certified by GHMT according to DTR-11801-9905 for 25GBASE-T in the Channel-Link with

More information

SC/APC Connector. CATV Active device Telecommunication. Metro Local Area Data processing

SC/APC Connector. CATV Active device Telecommunication. Metro Local Area Data processing Introduction As the industry s leading supplier of single-mode cable assemblies, Optical Fiber offers the most complete line of connectors and factory-terminated cables. From single-fiber jumpers to high

More information

2nd Edition. Product overview. Components for class E A. Cabling systems. Future-proof 10GBase-T solutions for your IT infrastructure

2nd Edition. Product overview. Components for class E A. Cabling systems. Future-proof 10GBase-T solutions for your IT infrastructure 2nd Edition Product overview Components for class E A Cabling systems with RJ45 Module MS-K Plus Cat.6 A (IEC) Future-proof 10GBase-T solutions for your IT infrastructure Copper Cabling system For the

More information

The Quality Connection. DClink The real Plug&Play solution Numerous possibilities, one system

The Quality Connection. DClink The real Plug&Play solution Numerous possibilities, one system The Quality Connection DClink The real Plug&Play solution Numerous possibilities, one system 2 Our best solution for your application DClink The real Plug&Play solution Fully ready-made and tested, DClink

More information

Data centre Cabling Product overview. Flexible and future-proof solutions for data centres TRADITION INNOVATION PASSION

Data centre Cabling Product overview. Flexible and future-proof solutions for data centres TRADITION INNOVATION PASSION Data centre Cabling Product overview Flexible and future-proof solutions for data centres TRADITION INNOVATION PASSION Contents page System solutions from a single source 3 Each solution has its own advantages

More information

Field-terminated RJ45 connector with housing. Color housing: gray (RAL 7042). Color termination block: red.

Field-terminated RJ45 connector with housing. Color housing: gray (RAL 7042). Color termination block: red. FM45 Connector Cat. 6 A IP20, 4P, TIA 568-A/B, 10x R815651 966704105 10 Stk. 090.7437 / ähnliche Abbildung Instruction manual Field-terminated connector with housing. Color housing: gray (RAL 7042). Color

More information

PreCONNECT BREAKOUT PRODUCT INFORMATION

PreCONNECT BREAKOUT PRODUCT INFORMATION PreCONNECT BREAKOUT PRODUCT INFORMATION PreCONNECT BREAKOUT Trunk Highly modular SMAP-G2 19 Distribution Panels Classical 19 1 and 2 HU Distribution Panels, fixed installation and telescopic complete pullout

More information

E-DAT C6A. The compact connection system of course with Cat.6A

E-DAT C6A. The compact connection system of course with Cat.6A E-DAT C6A The compact connection system of course with Cat.6A Intelligent system solution for structured cabling Nowadays the need for high data transfer rates is enormous. This not only applies to public

More information

Data sheet C6 A modul 90 jack

Data sheet C6 A modul 90 jack Illustrations Dimensional drawing Cut-out Page 1/7 See enlarged drawings at the end of document Product specification modular Cat.6 A termination unit RJ45 mounting version: module, 90 cable feed solid,

More information

PreCONNECT DUODECIM PRODUCT INFORMATION

PreCONNECT DUODECIM PRODUCT INFORMATION DUODECIM PRODUCT INFORMATION Applications Infrastructure and IT room cabling within data centers System consists of: Factory assembled FO breakout and loose tube cables, FRNC-LSZH indoor cables, up to

More information

Pretium EDGE Solutions Trunk Cable, OM4, Low-Loss, MTP to MTP, 24 fibres

Pretium EDGE Solutions Trunk Cable, OM4, Low-Loss, MTP to MTP, 24 fibres Corning Cable 143 Pretium EDGE Solutions Trunk Cable, OM4, Corning Cable Systems LANscape Pretium EDGE (Evolved -Density, Growth -Enabled) Solutions are high density pre -terminated optical cabling systems

More information

25G System The RJ45 building cabling with future

25G System The RJ45 building cabling with future 25G System The RJ45 building cabling with future INNOVATIONSPREIS-IT DEUTSCHER RECHENZENTRUMSPREIS 2018 3. PLATZ KATEGORIE 4: NETZWERK-INFRASTRUKTUREN BEST OF 2018 HARDWARE 2 METZ CONNECT 25G System Intelligent

More information

EDGE Solutions Trunk Cable, OM4, Low- Loss, MTP to MTP, 12 fibres

EDGE Solutions Trunk Cable, OM4, Low- Loss, MTP to MTP, 12 fibres EDGE MTP trunks are preterminated cables with 12 -fibre MTP connectors or LC duplex connectors on either side. The trunks build up the major skeleton of the passive network infrastructure, and thanks to

More information

MTP Multi Lite Trunk Assemblies

MTP Multi Lite Trunk Assemblies MTP Multi Lite Trunk Assemblies MTP Multi-Lite Trunk assemblies are a neat solution for providing up to four MTP -MTP links within a compact, high density ruggedised cable. The cable construction consists

More information

DIGITUS Fiber Optic Splice Box, 1U, basic housing, color grey (RAL 7035) or black (RAL 9005)

DIGITUS Fiber Optic Splice Box, 1U, basic housing, color grey (RAL 7035) or black (RAL 9005) DIGITUS Fiber Optic Splice Box, 1U, Basic Housing Basic housing for splice box assembly Sturdy housing Sliding Available in colors grey and black Abstract DIGITUS Fiber Optic Splice Box, 1U, basic housing,

More information

Opt-X Enterprise Fiber Trunk Cables

Opt-X Enterprise Fiber Trunk Cables APPLICATION Factory-terminated and tested fiber trunk cables connect central patching locations to zones or pods. Available terminated with both modular (MTP ) and discrete connectors, these trunks are

More information

Outstanding MTP cabling efficiency for your data center PreCONNECT OCTO: Less fibers, more performance. OPTICAL SOLUTIONS & INFRASTRUCTURE

Outstanding MTP cabling efficiency for your data center PreCONNECT OCTO: Less fibers, more performance. OPTICAL SOLUTIONS & INFRASTRUCTURE Outstanding MTP cabling efficiency for your data center : Less fibers, more performance. OPTICAL SOLUTIONS & INFRASTRUCTURE Digitalization is confronting organizations and companies with significant challenges,

More information

2.17 3M 19" Patchpanels

2.17 3M 19 Patchpanels 2.17 3M 19" Patchpanels Ordering Information > Splicing cassette Incl. strain relief and cable management Dimensions: 155 x 92 x 8 mm (H x W x D) Colour: RAL 9001 (cream white) PU: 10 pcs 29026-500 31

More information

Pretium EDGE Solutions Trunk Cable, OM3, Low-Loss, MTP to MTP, 24 fibres

Pretium EDGE Solutions Trunk Cable, OM3, Low-Loss, MTP to MTP, 24 fibres Corning LANscape Pretium EDGE (Evolved-Density, Growth -Enabled) solutions are high -density preterminated optical cabling systems that simplify installation and improve performance in data centre environments.

More information

Pretium EDGE HD Solutions A LANscape Pretium Solutions Product

Pretium EDGE HD Solutions A LANscape Pretium Solutions Product Pretium EDGE HD Solutions for Enterprise Data Centers and Storage Area Networks Corning Pretium EDGE HD solutions create a fiber optic tip-to-tip solution for data centers and storage area networks (SANs)

More information

Voice Integration Overview

Voice Integration Overview Voice Integration Overview 010.2936 Intelligent voice integration Highest packing density Modular design Efficient and tool-free connection technique Comprehensive product range Ingenious labelling system

More information

1 : LC/PC 0 : None S : Simplex 09 : 0.9mm G : Green W : White. A : LC/APC S : SM D : Duplex 20 : 2.0mm L : Blue. M : MM 30 : 3.

1 : LC/PC 0 : None S : Simplex 09 : 0.9mm G : Green W : White. A : LC/APC S : SM D : Duplex 20 : 2.0mm L : Blue. M : MM 30 : 3. LC Connector The LC connector was the first small form factor connector on the market. The use of a high performance 1.25 mm ferrule gives the connector extremely high performance characteristics. The

More information

Structured (premises) wiring systems: building backbone (riser) and/or horizontal cabling.

Structured (premises) wiring systems: building backbone (riser) and/or horizontal cabling. GIBT Breakout Cables Indoor I-V(ZN)HH 05-0- v6.0 Ordering Information Belden Part Numbers Fibre Description / count 4 6 8 4 6.5/5-OM GIBT0 GIBT04 GIBT06 GIBT08 GIBT GIBT4 50/5-OM BI GIBT0 GIBT04 GIBT06

More information

EDGE Solutions Trunk Cable, SMF-28 Ultra OS2, MTP to MTP, 12 fibres

EDGE Solutions Trunk Cable, SMF-28 Ultra OS2, MTP to MTP, 12 fibres EDGE MTP trunks are preterminated cables with 12 -fibre MTP connectors or LC duplex connectors on either side. The trunks build up the major skeleton of the passive network infrastructure, and thanks to

More information

Description and Assembly Instructions

Description and Assembly Instructions Description and Assembly Instructions Modular Industrial Patch Panel Release 01 12/11 Technical Support HAC.Support@Belden.com The naming of copyrighted trademarks in this manual, even when not specially

More information

Complex networks in Plug & Play

Complex networks in Plug & Play tml tde Modular Link System Complex networks in Plug & Play tml tde Modular Link System The number of network connections in a Data Center is increasing constantly, due to the ever greater demands made

More information

C6Amodul and C6Amodul K. The connection system for a wide variety of applications of course with Cat.6A

C6Amodul and C6Amodul K. The connection system for a wide variety of applications of course with Cat.6A C6Amodul and C6Amodul K The connection system for a wide variety of applications of course with Cat.6A Intelligent system solution for structured cabling Nowadays the need for high data transfer rates

More information

Data sheet C6 A modul 1 port 180 M AP pure white

Data sheet C6 A modul 1 port 180 M AP pure white Illustrations Dimensional drawing Page 1/7 See enlarged drawings at the end of document Product specification surface-mount termination unit with C6modul 180 certified to GHMT Cat.6 re-embedded PVP component

More information

RCC45 ➁ Overview / /

RCC45 ➁ Overview / / RCC45 ➁ Overview 010.2936 More future and modularity Integration of POF and power Guaranteed modularity Long-term investment protection Flexible cabling solution Fast and convenient installation 1 010.2721

More information

OMEGA MODULAR PATCH PANEL EMPTY ENCLOSURE

OMEGA MODULAR PATCH PANEL EMPTY ENCLOSURE OMEGA MODULAR PATCH PANEL EMPTY ENCLOSURE The Omega MPP enclosure is based on a 19" frame, with 4 empty module slots for MPP modules. Highly flexible : any mix between twisted pair and optical fiber modules.

More information

KRONE FiberPLUS Patchcords and Pigtails. Optical fibres with connectors. Ultra-PC Ultra-PC Polishing P olishing

KRONE FiberPLUS Patchcords and Pigtails. Optical fibres with connectors. Ultra-PC Ultra-PC Polishing P olishing KRONE FiberPLUS Patchcords and Pigtails now now available av ailable with with Optical fibres with connectors Ultra-PC Ultra-PC Polishing P olishing SC-SM types of polishing: PC, UPC, APC8, APC 9 PC, UPC:

More information

Better all-round. DataVoice Circular connectors STX M12x1 IP67 Connector series for industrial applications. PoE+ 10 GBE. coded.

Better all-round. DataVoice Circular connectors STX M12x1 IP67 Connector series for industrial applications. PoE+ 10 GBE. coded. Better all-round. X coded D coded 10 GBE PoE+ DataVoice Circular connectors STX M12x1 IP67 Connector series for industrial applications STX M12x1 IP67 connector series With the STX M12x1 IP67 connector

More information

Pretium EDGE Solutions Trunk Cable, 50 µm multimode (OM3)

Pretium EDGE Solutions Trunk Cable, 50 µm multimode (OM3) Pretium EDGE 133 Pretium EDGE Solutions Trunk Cable, 50 Pretium EDGE Solutions trunk cables utilize the MTP Connector, a 12 -fiber push/pull optical connector with a footprint similar to the SC simplex

More information

LC Connector. A High Density Fiber Optic Network Solution. Paul Kolesar Lucent Technologies, Bell Laboratories

LC Connector. A High Density Fiber Optic Network Solution. Paul Kolesar Lucent Technologies, Bell Laboratories A High Density Fiber Optic Network Solution Paul Kolesar Lucent Technologies, Bell Laboratories IEEE 802.3z Gigabit Ethernet March, 1997 Outline Design Background and Goals Product Family Overview Features

More information

FO Trunk Cable. FO Trunk Cable

FO Trunk Cable. FO Trunk Cable 5 FO Trunk Cable www.easylan.de FO Trunk Cable u 2 to 144 fibers u Various cable types u PC and APC polish u Tuned connectors u Gradations as desired u Up to IP67 u etc. 104 05 FO Trunk Cable Contents

More information

Aerial Façade. Cabinets and borders. Butt and Sleeves Closures for manholes and handholes

Aerial Façade. Cabinets and borders. Butt and Sleeves Closures for manholes and handholes 6. Building Risers 6. 3M Solutions for Building Risers Single Family Units Skyscrapers Aerial Façade Cabinets and borders Central Telecom POP Butt and Sleeves Closures for manholes and handholes Applications

More information

MTP Outdoor Cabling System

MTP Outdoor Cabling System The AFL MTPE (MTP Elite) Low Loss outdoor cabling system offers a market leading, low loss, fast and efficient connection system for underground (UG) and outside plant applications. These assemblies offer

More information

barpa Values Website & Social Network

barpa Values Website & Social Network barpa Hello! Welcome to our world. Have you heard about us? We are specialized in structured cabling systems for data networks. We are able to give you the full range, from cable to cabinets, fiber optic

More information

Solutions. Solutions FOR DATA CENTERS AND STORAGE AREA NETWORKS

Solutions. Solutions FOR DATA CENTERS AND STORAGE AREA NETWORKS Solutions Solutions FOR DATA CENTERS AND STORAGE AREA NETWORKS Xtreme8 is Opticonx s Base-8 cabling solution for easy migration of 10/40/100 and 400G parallel optics deployments in the data center. This

More information

Data Center & Cloud Computing Infrastruture Solutions DATASHEET. MTP/MPO-LC Breakout Cable Aseemblies High Density Cabling System

Data Center & Cloud Computing Infrastruture Solutions DATASHEET. MTP/MPO-LC Breakout Cable Aseemblies High Density Cabling System Data Center & Cloud Computing Infrastruture Solutions DATASHEET MTP/MPO-LC Breakout Cable Aseemblies High Density Cabling System REV.2.0 2018 MTP/MPO Breakout Cable 01 Description MTP/MPO breakout assemblies

More information

MTP Cabling Overview. MTP Cabling System

MTP Cabling Overview. MTP Cabling System MTP cabling architectures utilise varying cable and patchcord configurations as defined in TIA-568-C.0-2. These cables vary by gender, fibre orientation and pair management. AFL manufactures a large and

More information

TIA 942. no need for dust caps. Pretium EDGE Solutions

TIA 942. no need for dust caps. Pretium EDGE Solutions LANscape Pretium EDGE (Evolved-Density, Growth-Enabled) Solutions Innovative drawer-style hardware Bend-insensitive fibre cables Offers unprecedented patchcord/connector access while achieving the highest

More information

9/27/04 cci Cablecom Inc. 1

9/27/04 cci Cablecom Inc. 1 cci Cablecom Inc. 1 CCI Cablecom Inc. is a privately held, women owned corporation headquartered in Aurora, CO. We manufacture a variety of voice and datacom products. Cable applications Include: Local

More information

OPTICAL FIBER INTRODUCTION

OPTICAL FIBER INTRODUCTION OPTICAL FIBER INTRODUCTION Advantages of optical fiber as compared to copper cables are known. They feature a very high degree of isolation, as they are immune to crosstalk, electromagnetic interference

More information

Product information 19" 1U UniRack2 24xLC-Duplex G.652.D, PC, ceramic, C/2 R819330

Product information 19 1U UniRack2 24xLC-Duplex G.652.D, PC, ceramic, C/2 R819330 Product information 19" 1U UniRack2 24xLC-Duplex G.652.D, PC, ceramic, C/2 R819330 1 Pcs. 19" 1U slide-in unit, splice tray plate with 2 splice trays radius 40 mm, fastening material, labeling strips and

More information

EDGE8 Solutions. EDGE8 Solutions Introduction

EDGE8 Solutions. EDGE8 Solutions Introduction EDGE8 Solutions EDGE8 Solutions Introduction Corning ClearCurve bend-optimised multimode and SMF-28 single-mode optical fibres are the core element of the system ensuring reliability when designing custom-engineered

More information

FIBRE OPTIC ENCLOSURES SYDNEY MELBOURNE BRISBANE PERTH JCSTECH.COM.AU

FIBRE OPTIC ENCLOSURES SYDNEY MELBOURNE BRISBANE PERTH JCSTECH.COM.AU FIBRE OPTIC ENCLOSURES SYDNEY MELBOURNE BRISBANE PERTH JCSTECH.COM.AU FIBREOPTIC RACK MOUNT ENCLOSURE: FIXED The JCS Technologies fixed rack mountable fibreoptic break out enclosure is suitable for patching

More information

LC Adapters and Cable Assemblies

LC Adapters and Cable Assemblies LC Adapters and meet the growing demand for small form factor, high-density fiber optic connectivity with simplex, duplex, single-mode and multimode options. LC connectors reduce space requirements by

More information

PreCONNECT PURE: Reliable planning of data center cabling OPTICAL SOLUTIONS & INFRASTRUCTURE

PreCONNECT PURE: Reliable planning of data center cabling OPTICAL SOLUTIONS & INFRASTRUCTURE PreCONNECT PURE: Reliable planning of data center cabling OPTICAL SOLUTIONS & INFRASTRUCTURE PreCONNECT PURE is a milestone in the development of high-end IT cabling for data centers. It eliminates two

More information

Product information Patch Cord Cat. 6A, S/FTP, 4P, LSFRZH, gray, RJ45/s- RJ45/s, 1.0 m

Product information Patch Cord Cat. 6A, S/FTP, 4P, LSFRZH, gray, RJ45/s- RJ45/s, 1.0 m Product information Patch Cord Cat. 6A, S/FTP, 4P, LSFRZH, gray, RJ45/s- RJ45/s, 1.0 m R509858 101376015 10 pcs Cable identification: S/FTP Outer jacket: LSFRZH Conductor diameter copper strand: AWG 26/7

More information

Ethernet cabling. B Ethernet cabling. Ethernet cabling overview B 2. Cabling 4-poles IP 20 B.1 8 IP 65 / IP 67 B Cables B Tools B.

Ethernet cabling. B Ethernet cabling. Ethernet cabling overview B 2. Cabling 4-poles IP 20 B.1 8 IP 65 / IP 67 B Cables B Tools B. Ethernet cabling Contents Page B Ethernet cabling Ethernet cabling overview B 2 Cabling 4-poles B.1 8 B.1 22 Cables B.1 96 Tools B.1 104 Cabling 8-poles B.2 8 B.2 20 Cables B.2 90 Tools B.2 98 B 1 Profile

More information

ODB 54 Optical Distribution Box IP54

ODB 54 Optical Distribution Box IP54 Unlimited Possibilities in Fiber Optic Cabling IP54 IP54 LWL FTTx DataVoice ODB 54 Optical Distribution Box IP54 Less Fuss. More Flexibility. Universal Application. Wherever glass fiber connections have

More information

Product information 19" 1U UniRack 24xLC-Duplex OM4, PC, ceramic, Bm/3 R816749

Product information 19 1U UniRack 24xLC-Duplex OM4, PC, ceramic, Bm/3 R816749 Product information 19" 1U UniRack 24xLC-Duplex OM4, PC, ceramic, Bm/3 R816749 1 Pcs. Front panel with staggered arrangement of adapters. 19" 1U slide-in unit, splice tray plate with 2 splice trays radius

More information

Han-Brid. Contents Han-Brid Features Han-Brid Data interfaces Han-Brid Overview Han-Brid Cu

Han-Brid. Contents Han-Brid Features Han-Brid Data interfaces Han-Brid Overview Han-Brid Cu Contents Page Features... 19.02 Data interfaces... 19.03 Overview... 19.04 Cu... 19.06 F.O.... 19.08 Quintax 3 A... 19.10 RJ45 C... 19.12 USB / FireWire... 19.14 Han 4 A SC... 19.16 Hoods/Housings... 19.18

More information

PATCH-CORD. SC Patch-Cord APPLICATIONS AVAILABILITY FEATURES SPECIFICATIONS. Active device termination Local Area Networks (LANs)

PATCH-CORD. SC Patch-Cord APPLICATIONS AVAILABILITY FEATURES SPECIFICATIONS. Active device termination Local Area Networks (LANs) SC Patch-Cord APPLICATIONS CATV Metro Test equipment Active device termination Local Area Networks (LANs) Premise installations Telecommunicatio n networks Data processing networks Wide Area Networks (WANs)

More information

EDGE Solutions Hybrid Trunk, OM4, Low- Loss, MTP to LC Duplex Uniboot, 24 fibres

EDGE Solutions Hybrid Trunk, OM4, Low- Loss, MTP to LC Duplex Uniboot, 24 fibres EDGE MTP trunks are preterminated cables with 12 -fibre MTP connectors or LC duplex connectors on either side. The trunks build up the major skeleton of the passive network infrastructure, and thanks to

More information

A combination meeting top requirements

A combination meeting top requirements 58ELineTM The ELine PREMIUM system ELine 1200 EC7 ELine 500 RJ45 S ELine 250 RJ45 S ELine 250 RJ45 U A combination meeting top requirements ELine adapter clip ELine triple outlet by adapter clip ELine

More information

PreCONNECT COPPER are factory assembled copper data cable Trunks and Multijumper for Plug-and-Play installations.

PreCONNECT COPPER are factory assembled copper data cable Trunks and Multijumper for Plug-and-Play installations. are factory assembled copper data cable Trunks and Multijumper for Plug-and-Play installations. Trunk 6 channels/stranded screened single cables S-STP Cat.7, AWG 23 installation cable diameter 22,3 mm

More information

Data sheet C6 A modul 2 port 180 M UP pure white

Data sheet C6 A modul 2 port 180 M UP pure white Illustrations Dimensional drawing Page 1/7 See enlarged drawings at the end of document Product specification flush-mounted termination unit with C6 A modul 180 certified to GHMT Cat.6 A re-embedded PVP

More information

3M Fiber Distribution Units 8400 Series

3M Fiber Distribution Units 8400 Series Communication Markets Division 3M Fiber Distribution Units 400 Series Flexible options to meet growing needs in limited spaces 3M offers a full line of patch panel designs to simplify your cable management

More information

LC Connectors and Adapters

LC Connectors and Adapters , Adapters and Cable Assemblies meet the growing demand for small form factor, high-density fiber optic connectivity with simplex, duplex, singlemode and multimode options LC connectors reduce space requirements

More information

R&Mfreenet Advanced Cat 6A Shielded Connection Module

R&Mfreenet Advanced Cat 6A Shielded Connection Module R&Mfreenet Advanced R&Mfreenet Advanced Cat 6A Connection Module The R&Mfreenet Cat 6A shielded connection modules, part of the Advanced cabling system, are ideal for voice, fast data transmissions and

More information

Pretium EDGE Solutions Harness, 12 fibres,

Pretium EDGE Solutions Harness, 12 fibres, Corning Cable Systems LANscape Pretium EDGE (Evolved -Density, Growth -Enabled) Solutions are high density pre -terminated optical cabling systems that simplify installation and improve performance in

More information

The OpDAT Wall Distributor is a distributor for universal use in floor cabling or as a building distribution point in the equipment room.

The OpDAT Wall Distributor is a distributor for universal use in floor cabling or as a building distribution point in the equipment room. Product information Page 1/10 Illustration splice VIK closed Product description Properties: Wall-mount housing with two lockable swing doors, two different locks to separate network and building cabling.

More information

ADJUSTABLE FLOOR BOXES

ADJUSTABLE FLOOR BOXES ADJUSTABLE FLOOR BOXES TABLE OF CONTENTS Description Applications References Configuration type Installation Technical Data Mechanism compatibility Dimensions Description Floor housings for electrical

More information

Wall-mount box mini. Specifications

Wall-mount box mini. Specifications Wall-mount box mini DATA SHEET DB4124-E Issue C Page 1 of 1 For indoor use. For termination of optical connectors. Prepared for splicing of pigtails (splice holder included). Adapter plates exists for

More information

FMT4S. High Density Connectivity Solution

FMT4S. High Density Connectivity Solution FMT4S High Density Connectivity Solution 2 FMT4S Solution Illustration FMT4S Optical Distribution Frame (ODF) FMT4S series is an advanced ODF series offering premium quality Data Center connectivity solution.

More information

Siemon PON Fiber Cabling Solutions

Siemon PON Fiber Cabling Solutions Siemon PON Fiber Cabling Solutions WWW.SIEMON.COM 8 Siemon Enterprise PON Fiber Cabling Solution Siemon Enterprise Passive Optical Network (PON) Fiber Cabling Solution improves the modularity, flexibility

More information

Solutions FOR DATA CENTERS AND STORAGE AREA NETWORKS

Solutions FOR DATA CENTERS AND STORAGE AREA NETWORKS Solutions FOR DATA CENTERS AND STORAGE AREA NETWORKS Xtreme12 is Opticonx s Base-12 cabling solution for easy migration of 10/25/40/50/100 and 400G parallel optics deployments in the data center. This

More information

OPTICAL CABLE & CABLE ASSEMBLY

OPTICAL CABLE & CABLE ASSEMBLY OPTICAL CABLE & CABLE ASSEMBLY FIBER OPTIC INDOOR CABLE MM 50 m (OM2) MULTI LOOSE TUBE CABLE Indoor Thight Buffer LSOH, 4 core NVLINMM2004LSOH MM 62.5 m MM 50 m (OM2) MM 50 m (OM3 550+/ OM4) Direct Burial

More information

Product information 19" 3U Global Patch Panel 48xRJ45/u, Cat. 6, partly populated R302361

Product information 19 3U Global Patch Panel 48xRJ45/u, Cat. 6, partly populated R302361 Product information 19" 3U Global Patch Panel 48xRJ45/u, Cat. 6, partly populated R302361 1 Pcs. 19" 3U Global patch panel/u incl. cable tie shelf 12 connection module holders Global/u 3 Global blind covers

More information

MFP8 Cat.6 A Field assembly RJ45 plug series. Simpler all over. Simpler all round. Data Voice. PoE+ 500 MHz. Cat.6 A.

MFP8 Cat.6 A Field assembly RJ45 plug series. Simpler all over. Simpler all round. Data Voice. PoE+ 500 MHz. Cat.6 A. Simpler all over. Simpler all round. Communication Circuit Accessories 3UK4 Cat.6 A 500 MHz fully shielded PoE+ Data Voice MFP8 Cat.6 A Field assembly RJ45 plug series Less fuss. More flexibility. Here

More information

R&Mfreenet Advanced Cat 6 A Unshielded Connection Module

R&Mfreenet Advanced Cat 6 A Unshielded Connection Module R&Mfreenet Advanced R&Mfreenet Advanced Cat 6 A Connection Module The R&Mfreenet Cat 6 A unshielded connection modules, part of the Advanced cabling system, are ideal for voice, fast data transmissions

More information

EDGE8 MTP Trunk Cable

EDGE8 MTP Trunk Cable The EDGE8 trunks utilise 8 -fibre push/pull optical connectors that are pinned on both ends of the cable. The trunks are shipped with strain -relief clips that allow for tool -less installation in EDGE8

More information

TECHNICAL DATA SHEET Family code C2424SOLPCORD CAT 6 UTP Solid. version 1 LSNH PATCHCORD date page 1/5

TECHNICAL DATA SHEET Family code C2424SOLPCORD CAT 6 UTP Solid. version 1 LSNH PATCHCORD date page 1/5 page 1/5 Application: High Density Switch & Hub Working area cord and telecommunications equipment cord in Local Area Networking environments Support current and future Category 6 applications, such as:

More information

Application Note. Data Center Standards and Layouts

Application Note. Data Center Standards and Layouts Application Note Data Center Standards and Layouts 1. Data Center Standards In earlier times, a room in which one or more servers, a telephone system and active network components were located was often

More information

UTP Cat 5e cable (200 MHz) (PVC sheath)

UTP Cat 5e cable (200 MHz) (PVC sheath) JetLan is the only structured cabling system that includes all the passive components required for the installation or adaptation of your data network, as we include all the different types of high performance

More information

Pre-terminated Multi Fibre Cable Assemblies

Pre-terminated Multi Fibre Cable Assemblies AFL manufactures a broad range of factory terminated and tested multi-fibre cable assemblies. These assemblies are available in various fibre types and counts, cable constructions and connector options.

More information

6. Building Risers M Solutions for Medium Buildings. Description

6. Building Risers M Solutions for Medium Buildings. Description 6. Building Risers 6.2 3M Solutions for Medium Buildings Medium buildings with 5-8 levels / average of about 17 apartments Unbundling OUTSIDE the building or INSIDE the basement Options: - 1 fibre/apartment

More information

Accelerating Light STAR. Data Center High Density Connectivity Solution

Accelerating Light STAR. Data Center High Density Connectivity Solution Accelerating Light STAR Data Center High Density Connectivity Solution STAR High Density Connectivity Solution STAR is a cost-effective modular solution that harnesses ultra-high density pre-terminated

More information

Fiber Optical Cabling Infrastructure Offer

Fiber Optical Cabling Infrastructure Offer Fiber Optical Cabling Infrastructure Offer Zipcord Distribution Subunitized Distribution Armored Subunitized Distribution In/outdoor Distribution Armored In/outdoor Distribution Stranded Loose Tube High-Speed

More information

MPO LGX Cassette Module

MPO LGX Cassette Module DATASHEET Product updated on November 19, 2018 MPO LGX Cassette Module MPO LGX Cassette Modules provide secure transition between MPO and LC or SC discrete connectors. They are used to interconnect MPO

More information

Alternative Energy Solutions

Alternative Energy Solutions Alternative Energy Solutions Fiber Optic Cabling Solutions for Wind and Solar Farms VISIT US AT WWW.OFSOPTICS.COM Centralized Wind and Solar Farm Automation The power network is changing. It needs the

More information

Singlemode SC Connector Kits Polymer Crimp Body. Housing Boot. 3.0 mm Jacketed. Simplex Blue Blue. Duplex Blue Blue

Singlemode SC Connector Kits Polymer Crimp Body. Housing Boot. 3.0 mm Jacketed. Simplex Blue Blue. Duplex Blue Blue One-piece connector body: Fastest assembly Field installable Anaerobic adhesive compatible Compliant with JIS C-5973 Fibre Channel TIA FOCIS-3 Pre-radiused ceramic ferrules For 125 µm cladding diameter

More information

Product Catalogue. MPO / MTP Solutions

Product Catalogue. MPO / MTP Solutions Product Catalogue MPO / Solutions version 2017 Empowering businesses through innovative network solutions. We have been pushing boundaries and providing innovative products and solutions to clients around

More information

PreCONNECT OCTO PRODUCT INFORMATION

PreCONNECT OCTO PRODUCT INFORMATION PreCONNECT OCTO PRODUCT INFORMATION Applications Infrastructure and IT room cabling within data centers System consists of: Factory assembled OFNR Riser or OFNP Plenum rated n x 8 fiber Microunit Breakout

More information

Pretium EDGE FX Solutions

Pretium EDGE FX Solutions Pretium EDGE FX Solutions for Enterprise Data Centers and Storage Area Networks Corning Cable Systems Pretium EDGE FX Solutions create a fixed-tray fiber optic tip-to-tip solution for Data Centers and

More information

Data Voice The Cabling System with PLUS POINTS Professional Package System for Generic Building Cabling

Data Voice The Cabling System with PLUS POINTS Professional Package System for Generic Building Cabling Data Voice The Cabling System with PLUS POINTS Professional Package System for Generic Building Cabling DataVoice is a reliable professional package for designers, installers and users developed by Telegärtner

More information

STAR. Data Center High Density Connectivity Solution

STAR. Data Center High Density Connectivity Solution STAR Data Center High Density Connectivity Solution 2 STAR Solution Illustration Reach for the STAR: Data Center Connectivity that achieves new heights! Fibernet is proud to introduce the new STAR series,

More information

Guaranteed flexibility

Guaranteed flexibility LCS PATCH PANELS >>> equipped panels Guaranteed flexibility 327 23 327 09 With LCS mixed patch panels you can patch copper and optical fibre cables on the same panel These modular panels provide perfect

More information

Plug & Play Universal Trunks

Plug & Play Universal Trunks 1 1 22.88 115 0 Plug & Play 0 Plug & Play Universal Trunks Plug & Play Universal Systems MTP Trunks provide the backbone of the Plug & Play System. With non - pinned MTPs on both ends of the cable, these

More information

13-SDMS-01 REV SDMS-01, REV.00 SEC DISTRIBUTION MATERIALS SPECIFICATION DATE: G

13-SDMS-01 REV SDMS-01, REV.00 SEC DISTRIBUTION MATERIALS SPECIFICATION DATE: G 13-SDMS-01 REV. 00 SPECIFICATIONS FOR FIBER OPTIC CONNECTIVITY COMPONENTS (PATCH CORDS, PIGTAILS, FAN-OUT CABLES AND CONNECTORS FOR INTERNAL INSTALLATIONS) This specification is property of SEC and subject

More information

Cable assembly types. L tot. Total length* L tot end-to-end total (min. 0.5 except receptacles)

Cable assembly types. L tot. Total length* L tot end-to-end total (min. 0.5 except receptacles) CABLE ASSEMBLY TYPES Quantity - Please use one request form per cable assembly type End A Cable assembly types End B Patch cord Receptacle Gas tight receptacle L b Breakout L b Single Fiber Drawings are

More information