SPOT WELDING GUNS MEDIUM & HEAVY DUTY kva

Size: px
Start display at page:

Download "SPOT WELDING GUNS MEDIUM & HEAVY DUTY kva"

Transcription

1 SPOT WL US U & VY UTY -7 kv

2 SUSP SPOT WL US T. J. Snow stocks a variety of inventory and offers support services of all T portable and stationary resistance spot welding machinery. T s top of the line, self-contained suspended production spot welding guns with integrated transformers and microprocessorbased solid-state digital weld controls are available in and style configurations. ccessories, such as spring balancers and bridge rail systems are also available for installation. edium and eavy uty spot welding guns range from to 7 KV. eavy uty suspended guns have a higher capacity and are available with an integrated or external digital control. With a variety of arm and set-up configurations, units can be built to meet the customer s exact requirement. T portable spot welding guns are economical and ideal for high production environments. The portable spot welding guns provide consistent, quality welds which can be attributed to a robust design with reliable features. TURS: ntegrated microprocessorbased solid-state digital control uilt-in transformer meets SO 826 standards yro suspension allows 360 degree maneuverability Rotation lock feature allows securing gun in multiple positions djustable weld stroke Long weld stroke enables welding in difficult-to-reach areas Retraction stroke allows reaching into tough spots Trigger handle controls include 2 welding programs, retraction valve operation and weld, no weld function Water-cooled copper secondary circuit Safety features prevent accidental initiation 21 length power cable, air and water hoses included Lube-free pneumatic circuit eliates oil mist from the shop Oil-less chrome-plated cylinder and shaft extends life cycle OPTOL QUPT rms and electrodes (in addition to those listed in this brochure, many special configurations are available to satisfy various requirements). ounts Twin-handle mount one trigger handle, one grip handle mounts control handle to one side of spot gun, and additional grip handle on other side. Twin-trigger mount mount two control handles, one on each side of spot gun. vailable with either 2- or -position schedule selectors. Requires T70 control. Underside mount mounts control handle on underside of spot gun. Supply able Various lengths of supply cables/ hoses are available at customer s request. The standard length supplied is 21. vailable long-life shielded supply cable. 2

3 STR QUPT: Suspended Spot un with choice of built-in control unit (T300, T0 or T70) ntegrated earth leakage detection and circuit breaker/. ust specify voltage and frequency of welder at time of order. ntegrated ilter-regulator Unit with gauge. ncludes 21 of supply cable and hoses. mergency stop causes operation to cease immediately. OTROL UT T 300 (Standard ontrol) 2 welding programs with direct recall by toggle switch on trigger handle. Pre-weld, slope and impulse functions. Single and auto-repeat modes. Programg lockout switch with removable key (option 31). mergency Stop utton mmediately stops welder operation. OTROL UTS T 300 & T 0/70 vailable Parameters T 300 T 0/70 vailable Parameters T 300 T 0/70 Squeeze ~ ~ Slope down 00-2 ~ Squeeze ~ ~ old ~ Pre-weld ~ ~ Post-weld ~ Pre-power 01-99% 0-99% Post-power 0-99% old ~ 00-0 ~ old time ~ ~ Slope up ~ 00-2 ~ Off time 00-98/99 ~ ~ Weld ~ ~ urrent k Power 1 # of mpulses old % % k ~ ngle urrent ngle Pressure k bar ll times are given in cycles. OPTOL QUPT Water low Switch Prevents welding when water is not circulating Water low Switch through the welder. Prevents welding when Part water # 310 is not (L circulating - LL) through Part # 3106 the () welder. Part # 3107 (L - LL) Part # (L ()- LL) Part # 3106 () Part # 3107 (L - LL) Part # 3108 () Program Lockout Switch Removable Program key Lockout selector for lockout of Switch programg schedule. Removable key Part selector # 31 for (T lockout 300) of programg schedule. Part # 31 (T 300) alancers quipped with Rotating ook (Option R) and two-position lock-unlock switch, operable from the ground (Option ). or capacity, see the specifications table. ontrol Unit T 0/70 onstant urrent ode. 63 welding programs, 2 with direct recall by toggle switch on trigger handle. isplay of welding current (K) and conduction angle. Weld urrent or onduction ngle Limits. Stepper unction with programmable curve. utomatic retraction stroke function. Slope, impulse, pre- and post-weld functions. djustment of time in half-cycles. Weld counter. dditional Options T0 control allows direct selection between 2 programs T70 control allows direct selection between programs T70 has option for two handles, each of which can select between 2 programs ( total) 3

4 U UTY SPTOS un type 0% duty cycle kv 38 ax power kv Short circuit current k Thermal current at 100% k Secondary voltage V Supply voltage 60 z V 220 v or 0 v (gun is single voltage and must be specified at order time) able section up to 30 m mm /0 vac 6/32 80/0 80/0 80/0 0/80 rms spacing 6. () 6. ().7 (120) 8.9 (22) 6.1 (1) rms. length 7. (190) 7. (190) 9.8 (20) 9.8 (20) ax electrode force (8 bar) lbs (da) 629 (286) 7 (338) 660 (300) 90 (268) 129 (69) Working stroke (6-2) (-20) (-20) (6-2) (10-26) ax stroke (30-8) (28-0) (3-0) (3-0) (-60) rms length 2.6 (60) 31. (800) 2.6 (60) 0.6 (1030) ax electrode force (8 bar) lbs (da) 209 (9) 20 (93) 29 (3) 33 () Working stroke ax stroke ompressed air supply psi (bar) (18-72) 3.-. (90-10) 9 (6.) (18-73).0-.7 (102-16) 9 (6.) 9 (6.) (1-60) (8-120) 9 (6.) (0-100) (-22) 9 (6.) ir per 1000 spots at kp ( bar) m 3 7. ose inside Ø Water cooling at 20 kp (2. bar) gpm (lpm) 1.87 (7) 1.8 (7) 1.8 (7) 1.8 (7) 2.(8) ax thickness mild steel sheet with arms length, 90 arms in with arms L = 20 in (08 mm), 90 arms in with arms length, 90 arms cross wire Ø, 90 arms in in Welding rate per ute in (1 + 1 mm) class in ( mm) class in (2 + 2 mm) class in ( mm) class in (3 + 3 mm) class et weight (with cables, hoses, suspension and shortest arms) lbs (kg) 101 (6) (2) 7 (3) 121 () Packing box dimensions in 3321 (3 + 3) ( ) ( ) ( ) 12 x 33. x 21.7 (300 x 80 x 0) ( + ) (3 + 3) (2 + 2) (1 + 1) 12 x 33. x 21.7 (300 x 80 x 0) ( + ) Spring balancer short arms capacity required lbs (kg) (0-) (-60) (-60) short arms balancer require part # 9367R 9368R 9368R long arms capacity required lbs (kg) (-60) 13-1 (6-70) long arms balancer required part # 9368R 9368R Standard control part # T300 T300 T (1 + 1) 13 x.1 x 2.8 (330 x 20 x 630) 332 ( ) (3 + 3) (2 + 2) ( ) 13 x.1 x 2.8 (330 x 20 x 630) (60-6) 9368R 13-1 (6-70) 9369R T ( + ) ( ) (2 + 2) ( + ) (76) 29.9 x 1 x 19.7 (760 x 100 x 00) /80.0 (280) 9.8 (20) 129 (69) (10-26) (-60) 32.3 (820) 31 (196) (30-7) (130-17) 9 (6.) 7. 2.(8) ( + ) ( ) ( ) ( + ) (78) 29.9 x 1 x 19.7 (760 x 100 x 00) (80-90) (80-90) 9370R 9370R (9-10) (9-10) 9371R 9371R T0 T0 U UTY Specifications subject to change without notice.

5 U UTY -style / kv / T300 ntegrated ontrol -style / kv / T300 ntegrated ontrol RS OR 3321, 3322 L in 7. (190) 9.8 (20) 13.8 (30) 20 (08) 2.6 (60) 31. (800) Part # Part # Part # Part # USTO R OURTOS VLL - XPLS LU: RS TURS WT 3321 RS TURS WT 3322 L * Set weight (approx.) Short stroke Long Stroke L * Set weight (approx.) Short stroke Long Stroke lbs (da) lbs (kg) lbs (da) lbs (kg) 7. (190) 629 (286) 7.3 (3.3) 0.2 (6) 1.0 (2) 1.2 (30) 1.9 (8) 7. (190) 7 (338) 7.3 (3.3) 0.2 () 0.8 (20) 1.1 (28) 1.6 (0) 9.8 (20) 99 (227) 9. (.3) 0.3 (7) 1.2 (30) 1. (38) 2. (60) 9.8 (20) 90 (268) 9. (.3) 0.2 (6) 1.0 (2) 1. (3) 2.0 (0) 13.8 (30) 397 (8) 12.8 (.8) 1.6 (1) 2.0 (0) 3.1 (80) 13.8 (30) 38 (199) 12.8 (.8) 0.3 (8) 1.3 (3) 1.9 (7) 2.8 (70) 20 (08) 26 (120) 18.7 (8.) 0. (13) 2.2 (6) 2.8 (70). (2) 20 (08) 26 (120) 18.7 (8.) 0. (13) 2.2 (6) 2.8 (70). (2) 2.6 (60) 209 (9).3 (10.6) 0.7 (18) 2.8 (72) 3. (90). (10) 2.6 (60) 29 (3).3 (10.6) 0.6 (1) 2. (60) 3.3 (8).7 (120) * lectrode force at 87 psi (6 bar) 31. (800) 20 (93) 28.6 (13) 0.7 (18) 2.9 (73).0 (102).7 (16) * lectrode force at 87 psi (6 bar)

6 U UTY style / kv / T300 ntegrated ontrol -style / kv / T300 ntegrated ontrol 2. (60) (-20) 1.3 (32) USTO R OURTOS VLL XPLS LU: 90 rms 30 rms 6.9 (17) X 7.7 (19) L L ustom arm configurations available RS TURS WT 33 L * Set weight (approx.) part # lbs (da) lbs (kg) Short stroke Long Stroke 660 (300) 7.1 (3.2) 0.2 () 0.8 (20) 1. (3) 2.0 (0) L in 9.8 (20) 13.8 (30) 20 (08) 2.6 (60) Part # Part # Part # Part # * lectrode force at 87 psi (6 bar) RS TURS WT 332 L * Set weight (approx.) Short stroke Long Stroke lbs (da) lbs (kg) 9.8 (20) 90 (268) 9.9 (.) 0.2 (6) 1.0 (2) 1. (3) 2.0 (0) 13.8 (30) 38 (199) 13.2 (6) 0.3 (8) 1.3 (3) 1.9 (7) 2.8 (70) 20 (08) 308 (10) 19.2 (8.7) 0. (12) 1.9 (8) 2.6 (6) 3.8 (97) 2.6 (60) 29 (3).8 (10.8) 0.6 (1) 2. (60) 3.3 (8).7 (120) * lectrode force at 87 psi (6 bar) 6

7 U UTY -style / 38 kv / T0 ntegrated ontrol -style / 38 kv / T0 ntegrated ontrol 7

8 VY UTY SPTOS un type 0% duty cycle ax power Short circuit current Thermal current at 100% Secondary voltage Supply voltage 60 z* kv kv k k able section up to 30 m mm 2 220/0 vac** rms centerline distance nsulated arms connection Ø on insulated arms connection Ø Ø gyro suspension rms. length ax electrode force (8 bar) Working stroke ax stroke ompressed air supply ir per 1000 spots short stroke long stroke Ø supply hose Water cooling ax thickness mild steel sheet with standard arm length cross wire Ø V V mps lbs (da) psi (bar) m 3 /8 bar m 3 /8 bar gpm (lpm) in/class /class gun gun gun gun v or 0 v (gun is single voltage and must be specified at order time) 126 / 63. (10) 1.7 (2) 1.7 () 9.6 (2) 126 / 63. (10) 1.7 (2) 1.7 () 9.6 (2) 2 200/100.8 (18) 1.9 (7) 1.9 (9).6 (29) 2 20/12.8 (18) 1.9 (7) 1.9 (9).6 (29) 00 (00) (-30) (7-100) (6) / (3 + 3/) 0. (1) 00 (00) (-30) (7-100) (6) / (3 + 3/) 0.6 () 136 (620) (-30) (7-100) (6) / ( + /) 0.7 (18) 136 (620) (-30) (7-100) (6) / ( + /) 0.8 (20) Welding rate per 1/Welding class in (1 + 1 mm) o /class 70/ 70/ 12/ 12/ in ( mm) o /class 30/ 30/ 0/ 0/ in (2 + 2 mm) o /class 1/ 1/ 2/ 2/ in ( mm) o /class 10/ 10/ 17/ 17/ in (3 + 3 mm) o /class 6/ 6/ 10/ 10/ et weight lbs (kg) 2 (1) 7 (3) 17 (71) (7) (with cables, hoses, suspension without arms) alancer: standard arms part # Standard ontrol part # T70 T70 T70 T70 * Other voltage/frequency combinations are available ** Use class K slow blow fuses or circuit breaker with instantaneous trip RS OR 3020, 302, 3032, 300 RS OR 3020, 302, 3032, , , ustom arm configurations available 3020, , ustom arm configurations available 8

9 SPTOS un type 0% duty cycle kv aximum power kv Short circuit current k Thermal current at 100% k Secondary voltage V Supply voltage 60 z V able section up to 30 m mm 2 220/0 vac** mps rms spacing nsulated arms connection Ø on insulated arms connection Ø Ø gyro suspension rms. length ax electrode force (8 bar) Working stroke ax stroke rms length ax electrode force (8 bar) lbs (da) lbs (da) 3 300/ (312).6 (29) 10.0 (2) 1881 (8) Working stroke (-60) (-60) (-60) (-60) (-60) (-60) aximum stroke (180-20) (180-20) (180-20) (180-20) (180-20) (180-20) ompressed air supply psi (bar) ir per 1000 spots short stroke long stroke Ø supply hose Water cooling ax thickness mild steel sheet with standard arm length, 90 arms m 3 /8 bar m 3 /8 bar gpm (lpm) in/class /class with arms L = 20 in (08 mm), 90 arms in/class /class with arms length, 90 arms in/class /class cross wire Ø, 90 arms Welding rate per 1/Welding class in (1 + 1 mm) o /class in ( mm) o /class in (2 + 2 mm) o /class in ( mm) o /class in (3 + 3 mm) o /class et weight lbs (kg) (with cables, hoses, suspension without arms) alancer: short arms part # long arms part # / (219) 1.9 (7) 1.9 (9).6 (29) 10.0 (2) 1881 (8) (-20) (-70) 0.6 (1030) 39 (2) 0. (13) 2.2(8) / ( + /) / ( /) / (3 + 3/) 0.7 (18) 12/ 0/ 2/ 17/ 10/ 172 (78) v or 0 v (gun is single voltage and must be specified at order time) 2 20/ (219) 3 300/ (219) 2 200/ (312) 2 20/ (312) 1.9 (7) 1.9 (7) 1.9 (7) 1.9 (7) 1.9 (9) 1.9 (9) 1.9 (9) 1.9 (9).6 (29) 10.0 (2) 1881 (8) (-20) (-70) 0.6 (1030) 39 (2) 0. (13) 2.2 (8) / (. +./) / ( /) / (3 + 3/) 0.8 (20) 12/ 0/ 2/ 17/ 10/ 181 (82) (29) 10.0 (2) 1881 (8) (-20) (-70) 0.6 (1030) 39 (2) 0. (13) 2.2 (8) / (. +./) / ( /) / (3 + 3/) 0.8 (20) 12/ 0/ 2/ 17/ 10/ 192 (87) (29) 10.0 (2) 1881 (8) (-20) (-70) 0.6 (1030) 39 (2) 0. (13) 2.2 (8) / ( + /) / ( /) / (3 + 3/) 0.7 (18) 12/ 0/ 2/ 17/ 10/ 17 (79) (29) 10.0 (2) 1881 (8) (-20) (-70) 0.6 (1030) 39 (2) 0. (13) 2.2 (8) / (. +./) / ( /) / (3 + 3/) 0.8 (20) 12/ 0/ 2/ 17/ 10/ 183 (83) (7) 1.9 (9) (-20) (-70) 0.6 (1030) 39 (2) 0. (13) 2.2 (8) / (. +./) / ( /) / (3 + 3/) 0.8 (20) 12/ 0/ 2/ 17/ 10/ 19 (88) VY UTY Standard ontrol part # T70 * Other voltage/frequency combinations are available ** Use class K slow blow fuses or circuit breaker with instantaneous trip T70 T70 T70 T70 RS OR RS 31, OR 30, 31, 36, 30, 3, 36, 32, 3, 38 32, 38 T70 ustom arm configurations available L 10.0 (2).1 (08) 2.0 (610) 32.3 (820) 0.6 (1030) Part # Part # Part # Part # Part # Part #

10 VY L 2.8 (630) 2.8 (630) 2.2 (60) 2.2 (60) T RTTRST T - T TURS - OÉS T RTÉRSTQUS TQUS 3.6 (880) 3.6 (880) 3.8 (910) 3.8 (910) TOS TÉOS Y RTRÍSTS - T U TS T 39.0 (990) 39.0 (990) 0. (102) 0. (102) T RTTRST O LT - T TURS OÉS T RTÉRSTQUS 302 TQUS 1.9 (0) 1.9 (0) (0) (0) TOS TÉOS Y RTRÍSTS - in T U TS T.3 (1).3 (1) 18. (70) 18. (70). (10). (10).8 (18).8 (18) 38.2 (970) 8.7 (220) 38.2 (970) 8.7 (220) 39.2 (99) 9.1 (0) 39.2 (99) 9.1 (0) 2.8 (630) 2.8 (630) 2.2 (60) 2.2 (60) 33. (88) 33. (88) 33. (88) 33. (88) L O L Ø L 9.6 (2) 9.6 (2).6 (29).6 (29) 3.6 (880) 3.6 (880) 3.8 (910) 3.8 (910).1 (10) 39.0 (990).1 (10) 39.0 (990) 19.3 (90) 0. (102) 19.3 (90) 0. (102) 1.9 (0) 1.9 (0) 17.3 (0) 17.3 (0) O L ustom arm configurations available.3 (1).3 (1) 18. (70) 18. (70) 38.2 (970) 38.2 (970) 39.2 (99) 39.2 (99) 33. (88) 33. (88) 33. (88) 33. (88) Ø L 9.6 (2) 9.6 (2).6 (29).6 (29) SOS OR 3020, 302, 3032, 300 O.1 (10).1 (10) 19.3 (90) 19.3 (90) ustom arm configurations available O L VY UTY O O (10). (10).8 (18).8 (18) 8.7 (220) 8.7 (220) 9.1 (0) 9.1 (0) O - O SOS OR 31, 30, 36, 3, 32, 38 O O L (220) 8.7 (220) 8.7 (220) 12. (31) 12. (31) 12. (31) - - L O L 13. (30) 13. (30) 13. (30) 17.1 (3) 17.1 (3) 17.1 (3) 21.7 (2) 22. (70) 2. (622) 21.7 (2) 22. (70) 2. (622) 3.3 (870) 3.3 (870) 3.8 (88) 3.3 (870) 3.3 (870) 3.8 (88) 38.2 (970) 38.2 (970) 38.8 (98) 38.2 (970) 38.2 (970) 38.8 (98).9 (30).9 (30).9 (30).9 (30).9 (30).9 (30) 19.7 (00) 19.7 (00) 19.7 (00). (9). (9). (9) 39.2 (99) 39.2 (99) 39.2 (99) 39.2 (99) 39.2 (99) 39.2 (99) 33. (88) 33. (88) 33. (88) 33. (88) 33. (88) 33. (88) Ø L.6 (29).6 (29).6 (29).6 (29).6 (29).6 (29) 19.3 (90) 19.3 (90) 19.3 (90).0 (8).0 (8).0 (8) L psi (6 lbs (8 bar) rm Weight lbs (da) lbs (da) lbs (kg) 10.0 (2) 9 (6) 1881 (8) ~ 19.8 (9).1 (08) 96 (30) 126 (7) ~ 28.6 (13) 2.0 (610) 660 (300) 880 (00) ~ 37. (17) 32.3 (820) 06 (0) 671 (30) ~ 8. (22) 0.6 (1030) 07 (18) 39 (2) ~ 61.6 (28) ustom arm configurations available Specifications subject to change without notice. 10

11 SPR LRS (290) 1.1 (27) Ø 0.6 (1) O20 Ø 0.9 (22) Part # 912, 913, (270) 288 (=29) Part # (3) O22 27 > 1.0 (2) Part # lbs (kg) in lbs (kg) lbs (kg) lbs (kg) 912R 913R 922R load range stroke weight length packaging weight stroke packaging length ( ) ( ) ( ) (200) (27.8) (200) (28.8) (200) (38.7) (27.8) (31) (28.8) (32) 8 9 (38.7) (2.) (200) (31) (200) (32) (200) (2.) shipping dimensions.6 x 12.6 x 13 (600 x 320 x 330).6 x 12.6 x 13 (600 x 320 x 330).6 x 12.6 x 13 (600 x 320 x 330) LRS (660) 27.6 (700) 688 Option "R", lower swivel type hook. Option "", lock control from the floor. Ø 0.8 (20) O (22) 9. (20) Ø 0.7 (18) 8. (21) > 1.0 (2) load range stroke weight length packaging weight stroke packaging length shipping dimensions Ø 0. (12.) Part # lbs (kg) in lbs (kg) lbs lbs (kg) (kg) lbs (kg) 9367R ( - ) (2000) (12.) 2832 (12.) (1.) (2000) (1.) 17.9 x 10.6 x ( x 270 x 280) 9368R ( - 6) (2000) (13.6) 303 (13.6) (1.6) (2000) (1.6) 17.9 x 10.6 x ( x 270 x 280) 2.8 (630) 26. (670) 9369R 13 - (6-7) (2000) (1.) 36 (1.) (.) (2000) (.) 17.9 x 10.6 x ( x 270 x 280) Option "R", lower swivel type hook. Option "", lock control from the floor. 0. (12) 0.8 (22) Ø 0. (12.) 9. (20) Ø 0.7 (18) 9.8 (20) > 1.0 (2) load range stroke weight length packaging weight stroke packaging length shipping dimensions Part # lbs (kg) in lbs (kg) lbs (kg) lbs (kg) 26. (670) 2.8 (630) 9370R 9371R (7-90) (90-10) Option "R", lower swivel type hook. Option "", lock control from the floor (2000) (17.3) (2000) (18) 38 2 (17.3) (19) 0 (18) (20) (2000) (19) 78.7 (2000) (20) 17.9 x 10.6 x ( x 270 x 280) 17.9 x 10.6 x ( x 270 x 280) 0. (12)

12 OR T PROUTS VLL RO T. J. SOW ROKR R SPOT WLRS VRTL PRSS-TYP SPOT WLR 2-6 KV PORTL SPOT WLRS SPR PRTS & SUPPLS welders@tjsnow.com OW-SOW ( ) 120 owlin Ln, hattanooga, T 3721 () 89-6 PO ox 2287, hattanooga, T 3722

SPOT WELDING GUNS MEDIUM & HEAVY DUTY kva

SPOT WELDING GUNS MEDIUM & HEAVY DUTY kva SPOT WEDING GUNS MEDIUM & HEVY DUTY 16-7 kv DESIGNED FOR HIGH QUITY WEDS ND REDUCED INSTTION COSTS MEDIUM DUTY SPOT WEDING GUNS 16-38 KV rated @ 0% duty cycle, air operated and water-cooled. Integrated

More information

ISO*STAR (SXE, SXP) 5/2 & 5/3 Solenoid and pilot actuated glandless spool valves

ISO*STAR (SXE, SXP) 5/2 & 5/3 Solenoid and pilot actuated glandless spool valves *STR (SX, SXP) / & / > > Sub-base mounted, 99- s, or > > Specially coated glandless spool and sleeve for long trouble-free life > > Integral flow regulators available on and s for cylinder speed control

More information

Pressure switch KP. Data sheet

Pressure switch KP. Data sheet Data sheet Pressure switch KP The KP pressure switches can be used as safety switches against too low a suction pressure and / or too high a discharge pressure in refrigeration and air conditioning systems.

More information

Pressure switch KP. Data sheet

Pressure switch KP. Data sheet Data sheet Pressure switch KP The KP pressure switches can be used as safety switches against too low a suction pressure and / or too high a discharge pressure in refrigeration and air conditioning systems.

More information

TeSys IEC Contactors and Overload Relays

TeSys IEC Contactors and Overload Relays TeSys IEC Contactors and Overload Relays Making High-Fault Short-Circuit Current Ratings Simple Schneider Electric is an industry leader in IEC contactors and overload relays, and is recognized as the

More information

Thermostat KP. Data sheet. The KP Thermostats are single-pole, doublethrow (SPDT) temperature-operated electric switches.

Thermostat KP. Data sheet. The KP Thermostats are single-pole, doublethrow (SPDT) temperature-operated electric switches. Data sheet Thermostat KP The KP Thermostats are single-pole, doublethrow (SPDT) temperature-operated electric switches. They can be connected directly to a single-phase AC motor of up to approx. 2 kw or

More information

6 Buck Boost Transformers

6 Buck Boost Transformers 6 uck oost Transformers uck-oost transformers are small, single phase, dry type distribution transformers designed and shipped as insulating/isolating transformers. They have a dual voltage primary and

More information

A7 MIG Welder 450, Engineered for your profit. A7 MIG Welder 450 ENGINEERED FOR YOUR PROFIT. Kemppi K7 Welding equipment

A7 MIG Welder 450, Engineered for your profit. A7 MIG Welder 450 ENGINEERED FOR YOUR PROFIT. Kemppi K7 Welding equipment A7 MIG Welder 450 ENGINEERED FOR YOUR PROFIT Kemppi K7 Welding equipment 1(9) THE NEW STANDARD IN ROBOTIC MIG WELDING A7 MIG Welder 450 is the state-of-the-art solution for robotic arc welding, ideal for

More information

B64G - Olympian Plus plug-in system Filter/regulator

B64G - Olympian Plus plug-in system Filter/regulator BG - Olympian Plus plug-in system > > Port size: /... / (ISO G/PTF) > > High efficiency water removal > > Diaphragm and balanced valve design ensure good regulation characteristics > > on-rising adjusting

More information

K1F037MCH cam voltmeter switch - 3L and 3L-N A - for Ø 22 mm

K1F037MCH cam voltmeter switch - 3L and 3L-N A - for Ø 22 mm Characteristics cam voltmeter switch - 3L and 3L-N - 60-12 A - for Ø 22 mm Main Range of product Product or component type Component name [Ith] conventional free air thermal current Mounting location Fixing

More information

low voltage GLOBAL CATALOGUE RANGE Motor Control Contactors - Thermal Overload Relay s - Manual Motor Starters

low voltage GLOBAL CATALOGUE RANGE Motor Control Contactors - Thermal Overload Relay s - Manual Motor Starters CTLOGUE GLOBL RNGE 2. Motor Control Contactors - Thermal Overload Relay s - Manual Motor Starters 2. 2. Product Overview. 2.2 Overload Relay Setting Range 2. - 2.8 Product Specifications 2.9-2. Contactor

More information

Pressure switch Type KP

Pressure switch Type KP MAKING MODERN LIVING POSSIBLE Data sheet Pressure switch Type KP KP switchs are for use in refrigeration and air conditioning systems to give protection against excessively low suction or excessively high

More information

Dual rod cylinder with guide function for pick & place applications.

Dual rod cylinder with guide function for pick & place applications. ual Rod ylinder Series XS ø, ø, ø, ø, ø, ø32 ual rod cylinder with guide function for pick & place applications. Series XS Twice the thrust on-rotating accuracy ±. X TS Y Y G X - - ata all bushing bearings

More information

K1F003MCH cam ammeter switch - 3 circuits A - for Ø 22 mm

K1F003MCH cam ammeter switch - 3 circuits A - for Ø 22 mm Product data sheet Characteristics cam ammeter switch - 3 circuits - 90-12 A - for Ø 22 mm Complementary Main Range of product Product or component type Component name [Ith] conventional free air thermal

More information

AE/CE Series Industrial Control Transformers

AE/CE Series Industrial Control Transformers 5 AE/E Series Industrial ontrol Transformers SETION TA AE/E SERIES SERIES OPEN ORE INDUSTRIAL & OIL INDUSTRIAL ONTROL ONTROL TRANSFORMERS The Acme Electric AE and E Series Industrial ontrol Transformers

More information

Pressure switch KP. Data sheet

Pressure switch KP. Data sheet Data sheet Pressure switch KP KP switchs are for use in refrigeration and air conditioning systems to give protection against excessively low suction or excessively high discharge. KP switches are also

More information

XPSMP11123P module XPS-MP - 2 independent functions - 24 V DC

XPSMP11123P module XPS-MP - 2 independent functions - 24 V DC Characteristics module XPS-MP - 2 independent functions - 24 V DC Main Range of product Product or component type Safety module name Safety module application 1-Nov-2018 Preventa Safety automation Safety

More information

Description: IRB-540 Robot with 6-axis Flexi-Wrist Manipulator, S4P Controller, Conveyor Tracking, and Analog Paint Regulation (APR)

Description: IRB-540 Robot with 6-axis Flexi-Wrist Manipulator, S4P Controller, Conveyor Tracking, and Analog Paint Regulation (APR) Standard Module # Description: IRB-540 Robot with 6-axis Flexi-Wrist Manipulator, S4P Controller, Conveyor Tracking, and Analog Paint Regulation (APR) The IRB-540 Flexi-Wrist finishing robot is specifically

More information

Piston rod cylinder Guide cylinders Series MSN. Brochure

Piston rod cylinder Guide cylinders Series MSN. Brochure Brochure 2 ini slide, narrow version Ø 6-6 mm double-acting with magnetic piston cushioning: elastic with integrated ball rail guide 3 overview overview 9 Sensors and sensor mountings, accessories Sensor,

More information

63 to 125 A. Functions. Conformity standards. General characteristics. Changeover switches SIRCO VM1 changeover switches.

63 to 125 A. Functions. Conformity standards. General characteristics. Changeover switches SIRCO VM1 changeover switches. comut_004_a_1_cat Changeover switches switches 63 to 125 A switches are manually operated three or four pole switches. They provide, source inversion or switching under load between two low voltage power

More information

Universal Compact Extruded Cylinders

Universal Compact Extruded Cylinders Universal Compact Extruded Cylinders Clippard s new Compact, Extruded Body Cylinders are available in double acting, double rod, single acting spring return, and single acting spring extended models. Universally

More information

XPSMC16Z safety controller XPS-MC - 24 V DC - 16 input - 30 LEDs signalling

XPSMC16Z safety controller XPS-MC - 24 V DC - 16 input - 30 LEDs signalling Characteristics safety controller XPS-MC - 24 V DC - 16 input - 30 LEDs signalling Main Range of product Product or component type Safety module name Sep 30, 2018 Preventa Safety automation Configurable

More information

XPSMC16Z safety controller XPS-MC - 24 V DC - 16 input - 30 LEDs signalling

XPSMC16Z safety controller XPS-MC - 24 V DC - 16 input - 30 LEDs signalling Characteristics safety controller XPS-MC - 24 V DC - 16 input - 30 LEDs signalling Complementary Function of module Synchronisation time between inputs Power consumption Input protection type [Uc] control

More information

XPSMC32Z safety controller XPS-MC - 24 V DC - 32 input - 46 LEDs signalling

XPSMC32Z safety controller XPS-MC - 24 V DC - 32 input - 46 LEDs signalling Characteristics safety controller XPS-MC - 24 V DC - 32 input - 46 LEDs signalling Complementary Main Commercial Status Range of product Product or component type Safety module name Commercialised Preventa

More information

K1K015NZ4 cam stepping switch - 2-pole A - screw mounting

K1K015NZ4 cam stepping switch - 2-pole A - screw mounting Characteristics cam stepping switch - 2-pole - 60-12 A - screw mounting Complementary Number of steps 5 Main Range of product Product or component type Component name [Ith] conventional free air thermal

More information

Manual Clamps for Automotive Prototype Production

Manual Clamps for Automotive Prototype Production Manual Clamp interchangeable with 82M-6 This newest version provides more clamp arm variations and in addition two hold open devices. Opening angle can be reduced now. Page 15.2 New products 15.0 Notes

More information

AE/CE Series Industrial Control Transformers

AE/CE Series Industrial Control Transformers AE/E SERIES INDUSTRIAL ONTROL TRANSFORMERS AE/E Series Industrial ontrol Transformers The Acme Electric AE and E Series Industrial ontrol Transformers are designed specifically for machine tool control

More information

60 series, 2/2 or 3/2 Ball valve

60 series, 2/2 or 3/2 Ball valve >> Port size: Rp/..., /... >> Ideally suited for most general purpose applications >> Easy installation, simple operation and maintenance free >> -way ball valves with actuator interface conforming to

More information

Standard specifications BA006LFE01C01

Standard specifications BA006LFE01C01 Standard specifications BA006LF01C01 ###### 1st dition : August 30, 2016 KAWASAKI HAVY INDUSTRIS, LTD. ROBOT DIVISION Materials and specifications are subject to change without notice. Specification :

More information

XPSMC16ZP safety controller XPS-MC - 24 V DC - 16 input - 32 LEDs signalling

XPSMC16ZP safety controller XPS-MC - 24 V DC - 16 input - 32 LEDs signalling Characteristics safety controller XPS-MC - 24 V DC - 16 input - 32 LEDs signalling Main Range of product Product or component type Safety module name Mar 09, 2017 Preventa Safety automation Configurable

More information

ISO*STAR - ATEX version (SXE, SXP) 5/2 & 5/3 Solenoid and pilot actuated glandless spool valves

ISO*STAR - ATEX version (SXE, SXP) 5/2 & 5/3 Solenoid and pilot actuated glandless spool valves *STR - TX version (SX, SXP) / & / > > Sub-base mounted, 99- s, or > > Specially coated glandless spool and sleeve for long trouble-free life > > Integral flow regulators available on and s for cylinder

More information

SMS 4 / SMS 5 safety mat Product information

SMS 4 / SMS 5 safety mat Product information SMS 4 / SMS 5 safety mat Product information SMS 4 / SMS 5 safety mats Safety mats are used for the protection of man on machinery and plants with hazardous movements. Typical fields of application are,

More information

SAFETY PRESSURE MATS GENERAL PRODUCT FEATURES

SAFETY PRESSURE MATS GENERAL PRODUCT FEATURES SAFETY PRESSURE MATS 9 GENERAL PRODUCT FEATURES SCHMERSAL s Series SMS Safety Pressure Mats feature a 100% active area, low actuating force, rugged cable termination, durable unibody construction cable

More information

ISO STAR Solenoid & pilot actuated spool valves Sub-base 5/2 & 5/3, ISO #1... ISO #3

ISO STAR Solenoid & pilot actuated spool valves Sub-base 5/2 & 5/3, ISO #1... ISO #3 ISO STR Solenoid & pilot actuated spool valves Sub-base 5/2 & 5/3, ISO #... ISO #3 Specially coated glandless spool and sleeve for long life vailable with integral flow regulators on ISO # & #2 sizes ow

More information

LOCAL EXTRACTORS Pure advantages. The ideal extractor for industrial environments.

LOCAL EXTRACTORS Pure advantages. The ideal extractor for industrial environments. N new materials and a focus on design gives Movex PR many new and important advantages: - Unique ease of maneuverability. H - Hood designed for maximum capture PR's design is based on Movex's basic principles:

More information

RW-E. Overloads. Solid-State Overload Relays. Standard Features

RW-E. Overloads. Solid-State Overload Relays. Standard Features RW-E The new RW_E Solid State Overload relays are developed with cutting edge technology according to the most demanding standards worldwide. With its wide current/mp setting; the RW_E OL Relay can be

More information

Electrical Interconnection

Electrical Interconnection Electrical Interconnection Edition 208/ Rail-Mount Terminal Block Systems Full Line Catalog, Volume Edition 207/208 PCB Terminal Blocks and Connectors Full Line Catalog, Volume 2 Edition 207/208 2 Automation

More information

Contact protection relay

Contact protection relay Contact protection relay Ordering details SVR 450 08 F0000 The protects sensitive control contacts from excessive load. It can be used with latching function or without. Bounce time of control contacts

More information

Mechanical Dimensions: MIN A A C E F. WT. (lb)

Mechanical Dimensions: MIN A A C E F. WT. (lb) MS Phone:.0..09 Fax:.0..099 Part Number (V) SONRY RTINGS (RMS) The MS series of universal transformers is designed and built to meet U.S. and International Safety Standards These transformers are available

More information

LIQUID LEVEL CONTROLS. Conductance Actuated Probe Type. Series LPC General Purpose Liquid Level Controls. Electrical Ratings

LIQUID LEVEL CONTROLS. Conductance Actuated Probe Type. Series LPC General Purpose Liquid Level Controls. Electrical Ratings onductance ctuated Probe Type Series LP-2000 Industrial and commercial level sensing and pump control of cooling towers, tanks, water fountains, condensate units, and others. igital technology utilizing

More information

Electrical Components Catalog Universal MATE-N-LOK Connector System

Electrical Components Catalog Universal MATE-N-LOK Connector System Introduction Product Facts Pins and sockets can be intermixed in the same housing Positive polarization Rear cavity identification Contacts completely enclosed in housings Positive locking housings Insulation

More information

K1D004ACH cam switch - 4-pole A - for Ø 22 mm

K1D004ACH cam switch - 4-pole A - for Ø 22 mm Characteristics cam switch - 4-pole - 45-12 A - for Ø 22 mm Main Range of product Product or component type Component name [Ith] conventional free air thermal current Mounting location Fixing mode Cam

More information

Motion Control Dispense Systems

Motion Control Dispense Systems Motion Control Dispense Systems Robots vailable in both Benchtop and SCR model types, Loctite brand robots are designed to simplify the dispensing of adhesives and sealants onto complex surface configurations.

More information

PowerLogic power-monitoring units. EM1000 series power meter. Technical data sheet

PowerLogic power-monitoring units. EM1000 series power meter. Technical data sheet PowerLogic power-monitoring units power meter Technical data sheet Distributed By: MetersUSA www.metersusa.com Meters@MetersUSA.com 1 224 365 5935 Basic energy meters Functions and characteristics PB105460

More information

Dielectric Withstand and Ground Bond Testers

Dielectric Withstand and Ground Bond Testers Dielectric Withstand and Ground Bond Testers For Safety Agency Production Line Compliance Testing U.S. patent#: 5,548,501, 6,054,865. Other patents pending. Safety agency listed. ENHANCED GRAPHIC LCD The

More information

4-Pole Relay. 2 Coil. [V] Hz A1 A2 60 Hz A24 A1 A20 A2

4-Pole Relay. 2 Coil. [V] Hz A1 A2 60 Hz A24 A1 A20 A2 ulletin - Product Overview/Product Selection ulletin - Industrial Relay ontact cartridges convertible from.o. to.. and vice versa EM V coils Pneumatic timing unit Solid-state timing unit Overlap contacts

More information

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous Safety relay for monitoring E-STOP pushbuttons. Approvals Unit features Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous 1 auxiliary contact (N/C), instantaneous Safe separation of

More information

Ideal protection for your electrics: häwa cable ducts

Ideal protection for your electrics: häwa cable ducts Ideal protection for your electrics: häwa cable ducts Well Conceived The häwa group has established itself as an innovative and highly competent supplier to machinery and facility equipment companies in

More information

EFFICIENT AND STABLE POWER DISTRIBUTION Workside power distribution boards

EFFICIENT AND STABLE POWER DISTRIBUTION Workside power distribution boards 0 - Workside power distribution boards EFFIIENT AND STABLE POWER DISTRIBUTION. Workside power distribution boards from : These robust, electrical jack-of-all-trades meet every requirement for demanding

More information

XPSMC16ZPPACK safety controller XPS-MC - 24 V DC - 16 input - 32 LEDs signalling

XPSMC16ZPPACK safety controller XPS-MC - 24 V DC - 16 input - 32 LEDs signalling Characteristics safety controller XPS-MC - 24 V DC - 16 input - 32 LEDs signalling Main Range of product Product or component type Safety module name Sep 11, 2018 Preventa Safety automation Kit configurable

More information

TILBURY STEEL SERVICE CENTRE

TILBURY STEEL SERVICE CENTRE TILBURY STEEL SERVICE CENTRE 159 Queen Street North Tilbury, ON, N0P 2L0 Voice: 519-682-0000 Toll-Free: 1-800-565-1077 Fax: 519-682-0004 Email: tsales@tilburysteel.com STOCK BOOK & REFERENCE GUIDE Tilbury

More information

M55116 AUDIO & M55116 AUDIO TYPE CONNECTORS

M55116 AUDIO & M55116 AUDIO TYPE CONNECTORS M55116 UIO & M55116 UIO TYP ONNTORS THNIL SPIFITIONS Shell: Mating: Mating ycles: 3,000 Temperature: Insert Material: ontacts: urrent Rating: Voltage Rating: ontact epression: ontact Resistance: Insulation

More information

the Santon FCS-type switch Disconnect Superior Switch Solutions

the Santon FCS-type switch Disconnect Superior Switch Solutions the Santon FCS-type switch Disconnect Superior Switch Solutions The technical information given in this table applies to 3 and 4 pole fuse combination switches. FRAME SIZE 1 1 2 3 3 4 4a 4b 5 6 6 nominal

More information

Each VariSTAR Type AZU arrester must pass the following production tests: 100% Physical Inspection 100% Leakage Current Test 100% RIV Test

Each VariSTAR Type AZU arrester must pass the following production tests: 100% Physical Inspection 100% Leakage Current Test 100% RIV Test Surge Arresters VariSTAR Type AZU Heavy-duty Distribution Class Under-oil MOV Arrester Electrical Apparatus 235-64 GENERAL The Cooper Power Systems VariSTAR Type AZU under-oil MOV arrester is designed

More information

TEX. Spare parts list. Handheld pneumatic pick hammers 03PS Atlas Copco Construction Tools AB No

TEX. Spare parts list. Handheld pneumatic pick hammers 03PS Atlas Copco Construction Tools AB No TEX 0PS Spare parts list Handheld pneumatic pick hammers 0 Atlas Copco Construction Tools AB No. 9800 0976 0 004 TEX 0PS Contents Contents General information................................................................

More information

K1C024B body for BCD encoded output switch - 1 pole A - for Ø 22 mm

K1C024B body for BCD encoded output switch - 1 pole A - for Ø 22 mm Characteristics body for BCD encoded output switch - 1 pole - 45-12 A - for Ø 22 mm Main Range of product Product or component type Component name [Ith] conventional free air thermal current Sub-assembly

More information

Product Details. Contents. Features and Mounting Options for SUNNY STRING-MONITOR SSM24-11

Product Details. Contents. Features and Mounting Options for SUNNY STRING-MONITOR SSM24-11 Technical Information Product Details Features and Mounting Options for SUNNY STRING-MONITOR SSM24-11 Contents The Sunny String Monitor SSM24 11 is specifically designed for monitoring large PV generators.

More information

Series RT. Thermal overload relays. E culus. Thermal overload relays. for contactors from 0.16 to 850A. Standards. Approvals C.62.

Series RT. Thermal overload relays. E culus. Thermal overload relays. for contactors from 0.16 to 850A. Standards. Approvals C.62. for contactors from 0.16 to 850 ontrol circuit up to 690V Power circuit: - RT1, RT12: up to 690V - RT2, RT22, RT3, RT32, RT4/4L, RT5/5L & RT6/6L: up to 1000V Thermal protection against normal overloads.

More information

MCFCW-20-4HS-1 (4-Pipe) High Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 60,000 BTUH

MCFCW-20-4HS-1 (4-Pipe) High Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 60,000 BTUH MCFCW-20-4HS-1 (4-Pipe) High Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 60,000 BTUH 1 Chilled and Hot Water Fan Coil High Static 4-Pipe Nominal

More information

Safety Technique. SAFEMASTER C Multifunction Safety Module BH 5910

Safety Technique. SAFEMASTER C Multifunction Safety Module BH 5910 Safety Technique SAFEMASTER C Multifunction Safety Module BH 59 47 Block Diagram A+ A S S S4 S S S S4 S S S S4 S S4 S4 S44 S4 PTC Galvanic separation Monitoring logic Monitoring logic Galvanic separation

More information

Rugged MediaConverter

Rugged MediaConverter Rugged MediaConverter Installation Guide RuggedCom Inc. 30 Whitmore Road, Woodbridge, Ontario Canada L4L 7Z4 Web: http://www.ruggedcom.com/ Tel: (905) 856-5288 Fax: (905) 856-1995 Toll Free: (888) 264-0006

More information

Discovery SDT650. Site Preparation Guide. Revision A Issued March Page 1

Discovery SDT650. Site Preparation Guide. Revision A Issued March Page 1 Discovery SDT650 Site Preparation Guide Revision A Issued March 2017 Page 1 Table of Contents Table of Contents... 2 Ideal Setup... 3 System Components... 4 Instrument Measurements... 5 Utility Requirements...

More information

Positive-guided relay outputs: 4 safety contacts (N/O), instantaneous

Positive-guided relay outputs: 4 safety contacts (N/O), instantaneous ohne Abbildung Contact expansion module for increasing the number of available contacts Approvals PZE X4.1P with universal power supply Unit features Positive-guided relay outputs: 4 safety contacts (N/O),

More information

MIC-2 MKII & MIC-2 MKII DIN, Multi-instrument DATA SHEET

MIC-2 MKII & MIC-2 MKII DIN, Multi-instrument DATA SHEET & DIN, Multi-instrument DATA SHEET Measurements All 3-phase AC measurements True RMS 4-Quadrant energy Power Quality Analysis Replaces analogue meters RS-485 Modbus RTU protocol TCP/IP Modbus (optional)

More information

XPSMC16ZCPACK safety controller XPS-MC - 24 V DC - 16 input - 32 LEDs signalling

XPSMC16ZCPACK safety controller XPS-MC - 24 V DC - 16 input - 32 LEDs signalling Characteristics safety controller XPS-MC - 24 V DC - 16 input - 32 LEDs signalling Main Range of product Product or component type Safety module name Preventa Safety automation Kit configurable safety

More information

MCFCW-08-4LS-1 (4-Pipe) Low Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 24,000 BTUH

MCFCW-08-4LS-1 (4-Pipe) Low Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 24,000 BTUH MCFCW-08-4LS-1 (4-Pipe) Low Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 24,000 BTUH 1 Chilled and Hot Water Fan Coil Low Static 4-Pipe Nominal Size:

More information

K1D011B body for BCD encoded output switch - 1 pole A - for Ø 22 mm

K1D011B body for BCD encoded output switch - 1 pole A - for Ø 22 mm Characteristics body for BCD encoded output switch - 1 pole - 30-12 A - for Ø 22 mm Complementary Main Number of decimal 11 Switching angle 30 Range of product Product or component type Component name

More information

DIN Series MINIATURE CIRCUIT BREAKERS, RESIDUAL CURRENT CIRCUIT BREAKERS. Introducing the DIN Series High-quality, high-performance circuit breakers

DIN Series MINIATURE CIRCUIT BREAKERS, RESIDUAL CURRENT CIRCUIT BREAKERS. Introducing the DIN Series High-quality, high-performance circuit breakers DIN Series MINIATURE CIRCUIT BREAKERS, RESIDUAL CURRENT CIRCUIT BREAKERS Introducing the DIN Series High-quality, high-performance circuit breakers Features (1) All models fully comply with IEC regulations

More information

MCFCW-06-4HS-1 (4-Pipe) High Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 18,000 BTUH

MCFCW-06-4HS-1 (4-Pipe) High Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 18,000 BTUH MCFCW-06-4HS-1 (4-Pipe) High Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 18,000 BTUH 1 Chilled and Hot Water Fan Coil High Static 4-Pipe Nominal

More information

SED2 VFD NEMA Type 3R Bypass/Air Conditioner

SED2 VFD NEMA Type 3R Bypass/Air Conditioner SED2 VFD NEMA Type 3R Bypass/Air Conditioner Description The NEMA Type 3R Bypass with Air Conditioner allows SED2 to be employed in a harsh environment. The SED2 is designed specifically for HVAC applications

More information

CI-tronic Reversing contactor Type RCI

CI-tronic Reversing contactor Type RCI Data sheet CI-tronic Reversing contactor Type RCI RCI reversing contactors are designed for demanding forward/reverse control of three-phase AC motors. The zero cross switching method ensures very fast

More information

SPX PORTABLE X-RAY NDT SYSTEMS REV. A

SPX PORTABLE X-RAY NDT SYSTEMS REV. A P 1 O 7 onstant Potential Output xcellent Stability and Regulation Power actor orrected Input ircuitry igital Interface, thernet and RS-232 nd ed xposed node Portable, Repeatable, ccurate 100% uty ycle

More information

RESISTANCE WELDER MICROPROCESSOR CONTROL UNITS KITS KIT TE101 12XX KIT TE550 TE850 TE801. The most advanced resistance welding machines

RESISTANCE WELDER MICROPROCESSOR CONTROL UNITS KITS KIT TE101 12XX KIT TE550 TE850 TE801. The most advanced resistance welding machines RESISTANCE WELDER MICROPROCESSOR CONTROL UNITS KITS 12XX KIT TE101 KIT TE550 TE850 The most advanced resistance welding machines www.tecna.net KIT TE101 Item 38202 WELDING CONTROL UNIT TE101 (Kit item

More information

Combined Overcurrent and Earth-fault Relay SPAJ 141 C. Product Guide

Combined Overcurrent and Earth-fault Relay SPAJ 141 C. Product Guide Combined Overcurrent and Earth-fault Product Guide Issued: April 1999 Status: Updated Version: C/19.04.2006 Data subject to change without notice Features Three-phase, low-set phase overcurrent unit with

More information

Switch Disconnectors, Main and EMERGENCY-STOP Switches

Switch Disconnectors, Main and EMERGENCY-STOP Switches General data Overview Siemens G 2010 1 2 3 NSE0_01931b 4 5 6 7 1 uxiliary switch (3SB for 3K; 3KX for 3KE) 2 IP20 terminal cover (Operator side) 3 3K switch disconnector 4 rcing contacts (only for 3KE)

More information

Technical data. Safety parameters: see page 333. DC maximum residual ripple: 10% Supply voltage tolerance: DC consumption: Control circuit

Technical data. Safety parameters: see page 333. DC maximum residual ripple: 10% Supply voltage tolerance: DC consumption: Control circuit Safety module CS DM-01 Technical data Housing PA 6.6 polyamide housing, self-extinguishing, V0 acc. to UL 94 Protection degree IP40 (housing), IP20 (terminal strip) Dimensions see page 283, design A Two-hand

More information

Sensitive definite time or inverse time earth-fault stage for back-up residual earthfault

Sensitive definite time or inverse time earth-fault stage for back-up residual earthfault Issued: April 1999 Status: Updated Version: B/09.11.2001 Data subject to change without notice Features Sensitive restricted earth-fault protection stage for fast, selective earth-fault protection Sensitive

More information

3a. IEM Indoor Metal Clad Medium Voltage Switchgear 25KV a. Section INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std.

3a. IEM Indoor Metal Clad Medium Voltage Switchgear 25KV a. Section INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std. 3a. IEM Indoor Metal Clad Medium Voltage Switchgear 25KV 16346-1 3a. Section 16346 INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std. Relays) Part 1 General 1.1 CONDITIONS AND REQUIREMENTS: A. Refer to

More information

Heavy Duty Terminal Blocks

Heavy Duty Terminal Blocks General Information: are available in two styles Deadfront Type (1100, 1200, 985 and 0987 series) and Barrier Type (1500, 1600 and 1700 series). Ratings and Standards: The voltage ratings of terminal blocks

More information

MIC-2 Multi-instrument DATA SHEET

MIC-2 Multi-instrument DATA SHEET Measurements All 3-phase AC measurements True RMS 4-Quadrant energy Power Quality Analysis Replaces analogue meters RS-485 Modbus RTU protocol TCP/IP Modbus (optional) Profibus DP (optional) I/O modules

More information

PGR-6101 MANUAL GROUND-FAULT & INSULATION MONITOR

PGR-6101 MANUAL GROUND-FAULT & INSULATION MONITOR Tel: +1-800-832-3873 E-mail: techline@littelfuse.com www.littelfuse.com PGR-6101 MANUAL GROUND-FAULT & INSULATION MONITOR Revision 0-C-041918 Copyright 2018 by Littelfuse, Inc. All rights reserved. Document

More information

Clamping Systems. PClamp. PClamp N. PClamp E. Gewährleistung. Inhalt. RotoClamp. DiskClamp. LinClamp. PClamp

Clamping Systems. PClamp. PClamp N. PClamp E. Gewährleistung. Inhalt. RotoClamp. DiskClamp. LinClamp. PClamp Gewährleistung Inhalt N dvantages 1 Pneumatic clamping with high forces General information 2 Optimum safety clamping pneumatic failure locks the system The performance of hydraulic clamps will be achieved

More information

Standard Circulating Pumps

Standard Circulating Pumps Product review Range: 1 1 3Q [ m³/h] Hz - North America 1 3 1 1 1.x1 1.x x x3 x 1 1 Q [ US gpm] >Single-head pumps: Circulating pumps with flanged connection > Applications: Drinking-water circulation

More information

RT2Y Compact temperature switch intrinsic safety

RT2Y Compact temperature switch intrinsic safety ompact temperature switch intrinsic safety Main Features Excellent repeatability Fix dead band for control and alarm Resistant to accidental overtemperature Intrinsic safety Hazardous area 0, 1, 2 pplications

More information

Combined Overcurrent and Earth-fault Relay SPAJ 140 C. Product Guide

Combined Overcurrent and Earth-fault Relay SPAJ 140 C. Product Guide Combined Overcurrent and Earth-fault Product Guide Issued: April 1999 Status: Updated Version: C/18.04.2006 Data subject to change without notice Features Three-phase, low-set phase overcurrent unit with

More information

Voltage Current Front-mounting bracket

Voltage Current Front-mounting bracket Switching Power Supply S8PS Compact DIN-Rail Mounting Industrial Power Supplies with Capacities Up to 600 W Models range from 0 W to 600 W. Universal input: voltage range 0 to 240 VAC. Power Factor Correction

More information

K1B004TLH cam switch - 1 pole A - screw mounting

K1B004TLH cam switch - 1 pole A - screw mounting Characteristics cam switch - 1 pole - 30-12 A - screw mounting Main Range of product Product or component type Component name [Ith] conventional free air thermal current Product mounting Fixing mode Cam

More information

Spare parts list. Handheld pneumatic pick hammers CP 0222 CHIT, CP 0222 CHIT BS, CP 0222 CHOT BS.

Spare parts list. Handheld pneumatic pick hammers CP 0222 CHIT, CP 0222 CHIT BS, CP 0222 CHOT BS. Spare parts list Handheld pneumatic pick hammers CP 0 CHIT, CP 0 CHIT, CP 0 CHOT www.cp.com CP 0 CHIT, CP 0 CHIT, CP 0 CHOT 9800 00 0 CP 0 CHIT, CP 0 CHIT, CP 0 CHOT Contents Contents General information...............................................................

More information

SLATE. Digital I/O Module INSTALLATION INSTRUCTIONS R8001D4001

SLATE. Digital I/O Module INSTALLATION INSTRUCTIONS R8001D4001 SLATE Digital I/O Module R8001D4001 INSTALLATION INSTRUCTIONS Scan for more information Application SLATE brings configurable safety and programmable logic together into one single platform. The platform

More information

FIRST FLUID INVENTORY CONTROL SYSTEM TO USE MECHANICS PCS AS SYSTEM KEYPAD (VIRTUAL KEYPADS) Versatile and Dependable Fluid Inventory

FIRST FLUID INVENTORY CONTROL SYSTEM TO USE MECHANICS PCS AS SYSTEM KEYPAD (VIRTUAL KEYPADS) Versatile and Dependable Fluid Inventory LFC 5000 IS HIGH-END Versatile and Dependable Fluid Inventory Control and Management System Simultaneously control, dispense and monitor up to 300 locations using modular, building block system components

More information

K1F006ALH cam switch - 6-pole A - screw mounting

K1F006ALH cam switch - 6-pole A - screw mounting Characteristics cam switch - 6-pole - 45-12 A - screw mounting Complementary Main Range of product Product or component type Component name [Ith] conventional free air thermal current Product mounting

More information

Fluid Head Specifications... 1 Parts(GH03)... 2 Set up & Use Installing the Pan Handle... 8

Fluid Head Specifications... 1 Parts(GH03)... 2 Set up & Use Installing the Pan Handle... 8 User s Manual PR LU Thank you for purchasing -M professional heads and tripods. This manual is an important tool for personnel who operate and maintain this equipment. nside, you will find detailed information

More information

INSTRUCTION SHEET. Eaton Logic Controller ELCB Controllers

INSTRUCTION SHEET. Eaton Logic Controller ELCB Controllers 2010-12-10 5011699201-PBB1 Eaton Logic Controller ELCB Controllers INSTRUCTION SHEET [Applicable Controllers] ELCB-PB10 ELCB-PB14 ELCB-PB20 ELCB-PB30 ELCB-PB40 IL05001005E 002-1310020-02 Thank you for

More information

CROWN CLIP Series Sockets

CROWN CLIP Series Sockets OWN LIP Series Sockets Product Facts ompact design High performance OWN BND contacts urrents to 350 mps 1 Mates with solid or laminated blades Supports true hot-plug (current interruption)2 Float-mount

More information

Tél. +41 (0) CH la Chaux-de-Fonds Case postale 2320

Tél. +41 (0) CH la Chaux-de-Fonds Case postale 2320 AeRO 30 This lightweight, compact, single-hose low pressure, electric blasting system utilizes dry ice pellets in it s patented aerodynamic rotor assuring high reliability and a smooth pulse-free dry ice

More information

Series AME25-JZ 25 Watt AC-DC / DC-DC Converter

Series AME25-JZ 25 Watt AC-DC / DC-DC Converter FEATURES: Click on Series name for product info on aimtec.com Series AME-JZ I/O Isolation 000VAC Low Ripple and Noise Operating Temp: -0 C to +70 C Over Voltage Protection Over current Protection Up to

More information

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors Safety relay for monitoring E-STOP pushbuttons and safety gates. Approvals Unit features Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous 2 safety contacts (N/O), delay-on de-energisation

More information

Technical data. Housing Polyamide housing PA 66, self-extinguishing V0 acc. to UL 94. Supply Rated supply voltage (U n

Technical data. Housing Polyamide housing PA 66, self-extinguishing V0 acc. to UL 94. Supply Rated supply voltage (U n Safety module CS AT 0 Module for emergency stops, end position monitoring for movable guards with delayed contacts at the opening of the input channels, semiconductor outputs (e.g. light barriers and magnetic

More information

Micro-Ohmmeters. Digital 10A. Models 6240 & Measure low resistance with high accuracy. Selectable test current and resistance ranges

Micro-Ohmmeters. Digital 10A. Models 6240 & Measure low resistance with high accuracy. Selectable test current and resistance ranges Digital 10A Micro-Ohmmeters Models 6240 & 6250 Measure low resistance with high accuracy Selectable test current and resistance ranges 0.1µΩ resolution Simple one button press-to-start operation Software

More information

K1D012ULH cam changeover switch - 2-pole A - screw mounting

K1D012ULH cam changeover switch - 2-pole A - screw mounting Characteristics cam changeover switch - 2-pole - 90-12 A - screw mounting Main Range of product Product or component type Component name [Ith] conventional free air thermal current Product mounting Fixing

More information