1 AXA 2400 Illustrated Parts List GPU 30-90kVA CE & UL Table of Content AXA 2400 GPU...1 Front and Back View - Outside...1 Front Door Inside...2 Front view - Inside with Cover...3 Front view Inside behind lid...4 Rear View...5 Remote Control Boxes...6 Remote - 1 x 400 Hz Output...6 Remote - 2 x 400 Hz Output...7 Remote - 1 x 400 Hz & 1 x 28 VDC Output (ARU)...8 Remote - 1 x 400 Hz Output & controls for Retriever/Hoist...9 ARU illustrated parts list Front View (completet unit) Front View (ARU) Back View (ARU)... 12
2 AXA 2400 GPU Please refer to for recommended list of spare parts. It is also possible to find diagrams and drawings of the unit at this website. Front and Back View - Outside Comp. No.: Name (Part no.) Polycarbonate Keyboard Cover (278164) Frame for Cover (278165) Membrane Keyboard (DV3011) Air filter (AM0131) S1: Emergency Stop (AF0403) Emergency Stop sign (AF0402) Air filter for plinth (AM0067) Drawing No rev. - / CFR Page 1 of 12
3 Front Door Inside Inside Polycarbonate Cover (278116) A3: Display (579536) Cable with SUB-DB9 (SC0176) Locking Brick (278124) S1: Emergency Stop (AF0403) Manual holder (KA1031) Drawing No rev. - / CFR Page 2 of 12
4 Front view - Inside with Cover Cover for IO-Zone (278150) F5: Fuse 10A (SI2066) F4: Fuse 5A (SI2075) F1-F3: Fuse 2A (SI2076) Q4: Circuit Breaker (DP0222) Handel (AF0249) Drawing No rev. - / CFR Page 3 of 12
5 Front view Inside behind lid PM1: Power Module - CE (578100) PM1: Power Module - UL (578105) Q5: Relay Module (KO4376) A1: Control Board (579526) Q4: Circuit Breaker (DP0222) A2: Interface Board (579527) Q2: Output 1 (KO4382) G1: Power Supply (PS0010) Q3: Output 2 (KO4382) - Optional X1/X2: I/O Terminals (291280) Consisting of 18 pcs. Feedthrough terminal (KM0200) Q1: Input Disconnector - CE (AF0267) Q1: Input Disconnector - UL (AF0268) T5: Current Transformer (IT0032) Located behind Interface board module A5: Capacitor Board (579532) Located behind Interface board module Drawing No rev. - / CFR Page 4 of 12
6 Rear View Illustrated Parts List - AXA 2400 Compact kva R7-R9: Varistors (VR6115) C7-C9: Output Capacitors (KP7087) M1-M2: Fan (VN0017) L1, T1, T2: Magnetic Assembly CE (IT0040) L1, T1, T2: Magnetic Assembly UL (IT0041) Drawing No rev. - / CFR Page 5 of 12
7 Remote Control Boxes Here are the available remote control boxes illustrated: 1) x 400 Hz Output 2) x 400 Hz Output 3) x 400 Hz & 1 x 28 VDC Output (ARU) 4) x 400 Hz Output & controls for Retriever/Hoist The four different remotes are illustrated below and the inside of the remote box is illustrated in the end. Remote - 1 x 400 Hz Output Complete unit: (578806) Polycarbonate Keyboard Cover (278164) Frame for Cover (278165) Control Box (534172) Membrane Keyboard (DV3027) S1: Emergency Stop (AF0403) Yellow Sticker (DV3014) Drawing No rev. - / CFR Page 6 of 12
8 Remote - 2 x 400 Hz Output Complete unit: (578818) Polycarbonate Keyboard Cover (278164) Frame for Cover (278165) Control Box (534172) Membrane Keyboard (DV3012) S1: Emergency Stop (AF0403) Yellow Sticker (DV3014) Drawing No rev. - / CFR Page 7 of 12
9 Remote - 1 x 400 Hz & 1 x 28 VDC Output (ARU) Complete unit: (578819) Polycarbonate Keyboard Cover (278164) Frame for Cover (278165) Control Box (534172) Membrane Keyboard (DV3013) S1: Emergency Stop (AF0403) Yellow Sticker (DV3014) Drawing No rev. - / CFR Page 8 of 12
10 Remote - 1 x 400 Hz Output & controls for Retriever/Hoist Complete unit: (578820) Outside view Polycarbonate Keyboard Cover (278164) Frame for Cover (278165) Control Box (534172) Membrane Keyboard (DV3010) S1: Emergency Stop (AF0403) Yellow Sticker (DV3014) Drawing No rev. - / CFR Page 9 of 12
11 Inside View Illustrated Parts List - AXA 2400 Compact kva Inside Polycarbonate Cover (278116) A3: Display (579536) Locking Brick (278124) S1: Emergency Stop (AF0403) Serial Cable Bridge (KB4103) Or Serial Cable Mobile (KB4104) Drawing No rev. - / CFR Page 10 of 12
12 ARU illustrated parts list Front View (completet unit) Q3: Output 2 (KO4382) G2: Power Supply (PS0010) X1: Terminal Block (291280) X2: Terminal Block (291280) E1: Heater (578829) - Optional ARU Module - UL (578826) ARU Module - CE (578821) Output Terminals Drawing No rev. - / CFR Page 11 of 12
13 Front View (ARU) ARU Power Module -CE (570108) ARU Power Module -UL (570109) Output Terminals + / - Back View (ARU) 3 ARU Transformer (556691) 3 ARU Transformer (556692) Drawing No rev. - / CFR Page 12 of 12
Illustrated Parts List - AXA 2400 Compact kva
1. Illustrated parts list Please refer to www.itwgse.com/axapower for recommended list of spare parts. It is also possible to find diagrams and drawings of the unit at this website. Comp. No.: Name (Part
More informationT702C US. Outer casing
T702C US Outer casing 101 103 107 108 106 134 133 136 130 112 139 114 140 119 132 ASKO, T702C US - Titan (TD25.1) Pos Spare part No. Description Qty Comment 101 8061817-81 Top WM50 titanium 1 Pc's 101-a
More informationSentron 3VT circuit breakers Simply Smart: First choice for power distribution
s Sentron 3VT circuit breakers Simply Smart: First choice for power distribution www.siemens.com/industry Sentron 3VT Molded Case Circuit-Breakers - 10-1600Amperes With the standard line of 3VT molded-case
More information900-4RL Option Board. Refer to installation instructions for compatible supply models - PS902, PS904, PS906, and PS914. Note
*44487080* 44487080 DANGER To avoid risk of electric shock, turn off AC power to power supply before installing or wiring option board. 900- Option Board Installation Instructions 900- Specifications Inputs
More informationAir-insulated medium-voltage secondary distribution switchgear
DISTRIBUTION SOLUTIONS Air-insulated medium-voltage secondary distribution switchgear Compact size Complete solution Factory tested Air-insulated medium-voltage secondary distribution switchgear The ABB
More informationPower supply. Phases: 3. Short-circuit capacity 10 ka AGS
5113003 Power supply Voltage: 400 V AC Phases: 3 Frequency: 50 Hz Current: 6 A Short-circuit capacity 10 ka AGS CE marking location The CE marking is located on the outside of the door, in the upper left
More informationSiemens AG I IA CE CP R&D-VI 4 WERNER-VON-SIEMENS-STRASSE AMBERG, GERMANY
Issued to: Siemens AG I IA CE CP R&D-VI 4 WERNER-VON-SIEMENS-STRASSE 48 92220 AMBERG, GERMANY This is to certify that Auxiliary Devices representative samples of 3UF70 followed by 0 or 1 followed by 0
More informationPOWERTEC 305S, 365S, 425S & 505S
POWERTEC 305S, 365S, 425S & 505S IM3023 11/2009 Rev. 0 Spare Parts... 1 POWERTEC 305S, 365S, 425S & 505S... 1 Figure A: Machine Assembly 1-305S... 2 Figure B: Machine Assembly 2-305S... 3 Figure C: Machine
More informationParts List, Charging Chart, Wiring Diagrams
Parts List, Charging Chart, Wiring Diagrams PHH150, PHH180 3 Phase PACKAGE HEAT PUMP UNITS TABLE OF CONTENTS PARTS LIST------------ 2-5 PARTS DRAWING - - - - - - -6-16 CHARGING CHARTS - - - - - - - 17
More informationMOTOR PROTECTION CIRCUIT BREAKERS
MOTOR PROTECTION CIRCUIT BREAKERS PAGE -2 PAGE -2 SMA Thermal trip adjustment ranges 9-32A (5 choices) Breaking capacity Icu at 400V: 50kA Suitable for mounting in consumer switchboards with minimum 58mm
More informationDaikin McQuay. Centrifugal Chiller LiquiFlo 2.0 Water-Cooled VFD VF2037, VF2055, VF2080, VF2110
Replacement Parts List No. 70002300 Revision B 08/204 Daikin McQuay Centrifugal Chiller LiquiFlo 2.0 Water-Cooled VFD VF2037, VF2055, VF2080, VF20 To find your Daikin Applied parts distributor, call -800-377-2787
More informationModel QRS CPVS
SPARE PARTS LIST EN CP COMPRESSOR Model QRS 0-5 - 0 CPVS 0-5 - 0 6 05 50 65 KEY - Door Panel: 655900 Lock - Door Panel: 005076 QRS 0 CONTENTS Title Page MAINTENANCE HOW TO READ THIS SPARE PART LIST? KIT
More informationReliable Switchgear from One Proven Supplier
Catalogue Industrial Switchgear 2007/2008 Reliable Switchgear from One Proven Supplier Xtra Combinations Xtra Combinations from Moeller offers a range of products and services, enabling the best possible
More informationDatasheet - MZM 100 B ST2-1P2PW2RE-A
19.03.2014-11:42:51h Datasheet - MZM 100 B ST2-1P2PW2RE-A Solenoid interlock / MZM 100 Preferred typ Actuator monitored Automatic latching Solenoid interlocks (for the protection of man) with innovating
More informationUnitary Controller. Features. Description. Technical Specification Sheet Rev. 6, March, 2000
Technical Specification Sheet Rev. 6, March, 2000 Unitary Controller The Unitary Controller can operate as an independent stand-alone controller, or can be connected to the APOGEE Automation System via
More informationATV1200A kv kva
Characteristics medium voltage variable speed drive ATV1200-10 kv - 5000 kva Main Range of product Altivar 1200 Product or component type Device short name Product destination Product specific application
More informationATV1200A kv kva
Characteristics medium voltage variable speed drive ATV1200-3.3 kv - 3500 kva Main Range of product Altivar 1200 Product or component type Device short name Product destination Product specific application
More informationATV1200A kv kva. Phase-shifting transformer Medium voltage arrestors Cooling fans Human machine interface Plinth (2) Power cells (9)
Characteristics medium voltage variable speed drive ATV1200-3.3 kv - 370 kva Main Range of product Altivar 1200 Product or component type Device short name Product destination Product specific application
More informationD5132 US. Base and related parts
D5132 US Base and related parts 135 101 142 102 140 119 141 137 140 134 105 133 148 111 108 125 ASKO, D5132 US - SS (DW70.5) Pos Spare part No. Description Qty Comment 101 8801387 BOTTOM OUTER COMPL. 1
More informationMASTER SERIES XE36 XPRESS GRILL (Electric) NON-CE & CE VERSION
MASTER SERIES XE36 XPRESS GRILL (Electric) NON-CE & CE VERSION PA R TS LI IS T Toll Free Phone, (US & Canada): (800) 427-6668 Toll Free Fax, (US & Canada): (800) 361-7745 http://www.garland-group.com FORM
More informationAppliance with Electronic Oven Control NOTICE SAFE SERVICING PRACTICES IMPORTANT NOTES DATA SHEET ABBREVIATIONS AND TERMINOLOGY
SERVICE DATA SHEET Appliance with Electronic Control 318204820 (1227) Rev. C NOTICE This service data sheet is intended for use by persons having electrical and mechanical training and a level of knowledge
More informationParts List, Charging Charts, Wiring Diagrams
Parts List, Charging Charts, Wiring Diagrams PAS072-150 SERIES PACKAGE AIR CONDITIONER UNITS TABLE OF CONTENTS PAS072 PARTS LIST -------------- 2-4 PAS072 PARTS DRAWING - - - - - - - - - 5-8 PAS090-150
More informationPOWERVAR SECURITY PLUS SERIES DETAILED UPS SPECIFICATION (8kVA 10kVA)
POWERVAR SECURITY PLUS SERIES DETAILED UPS SPECIFICATION (8kVA 10kVA) A55-00017 SEC PLUS 8-10 KVA MAREKTING SPECS REV. A 9/10 8kVA, 10kVA POWERVAR Isolated On-Line UPS Specifications Index 1.0 General
More informationSIEMENS HEALTHCARE INTEGRATED ELECTRICAL CABINET
Product Data Sheet Technical Publications SIEMENS HEALTHCARE INTEGRATED ELECTRICAL CABINET for ARTIS Q / Q.ZEN / ZEE BIPLANE IECAX480V225A Main Disconnect Panel Bevco Engineering Company, Inc. CONFIDENTIAL
More informationMNS Platform, low voltage systems Rear Access Power Motor Control Center. Alberto Carini, Global Product Manager
MNS Platform, low voltage systems Rear Access Power Motor Control Center Alberto Carini, Global Product Manager MNS Platform, low voltage systems Add Value to our customers Sales After sales Maximum safety;
More informationSPARE PARTS LIST CP COMPRESSOR. Model CPD CPD 75
SPARE PARTS LIST CP COMPRESSOR Model CPD 75-00 EN 05 0 5 CPD 75 CONTENTS Title Page MAINTENANCE HOW TO READ THIS SPARE PART LIST? MAINTENANCE KITS STANDARD UNITS MOTOR-COMPRESSOR UNIT -7 AIR CIRCUIT -9
More informationPurpose of High Voltage Circuit Switchers
Purpose of High Voltage Circuit Switchers Vertical interrupter circuit switcher without integral disconnect switch (Figure 2) Three-phase Interruption and Protection Circuit switchers have been developed
More informationMetering Devices IQ 300
Effective: May 2001 Page 1 New Information Contents Description Page General Description......... 2 Specifications.............. 3 Field Wiring Connections.... 4 Page 2 Effective: May 2001 Applications
More informationSENTRON 3VL Molded Case Circuit Breakers
Siemens AG SENTRON VL Molded Case Circuit Breakers Switching, Protection, Measuring and Monitoring Devices For the operating range from A to 00 A, the molded case circuit breaker ensures the optimum overload
More informationMetering Devices, Protective Relays, Software and Connectivity. Pre-Wired Control Power, Voltage and CT Inputs
.3 Features and Benefits Saves installation time and cost One part number to order; no need to worry that any part has been left out Pick the meter or meters you need as it is designed to fit various Eaton
More informationRoom Controllers. SC3000 Relay Pack
Compatible with SmartStruxure solution SmartStruxure Lite solution Room Controllers SC3000 Relay Pack The SC3000 is a relay pack for line-voltage fan coil units. The device is used with SER7300 and SER8300
More information9926 Series Branch Rated Circuit Breakers AC Version
Branch Rated AC Version Hydraulic Magnetic Single pole and double pole versions 20/240 VAC, 50/60 Hz Up to 25A Just 3 mm wide Mounts on 35mm DIN-rail UL 489 listed, CSA C22.2 No. 5-02, CE VDE Ordering
More informationPropeller Proto Board (#32212) Propeller Proto Board USB (#32812) Proto Board Accessory Kit (# )
Web Site: www.parallax.com Forums: forums.parallax.com Sales: sales@parallax.com Technical: support@parallax.com Office: (916) 624-8333 Fax: (916) 624-8003 Sales: (888) 512-1024 Tech Support: (888) 997-8267
More informationCisco CRS 16-Slot Chassis Power Systems
This chapter includes the following sections: Power specifications are provided in Technical Specifications Power Systems Overview, on page 1 Power Component Information Common to the Two Types of Power
More informationRuggedMC RMC40 RUGGEDCOM ISO 9001 REGISTERED. Features and Benefits. 4-Port Ethernet Media and Speed Converter
Features and Benefits 4-Ethernet Ports with Optional Dual Fiber Optics Three configurations to choose from: z2 10/100TX ports + 1 100FX port (SC/ST) z2 10/100TX ports + 2 100FX port (MTRJ/LC) z4 10/100TX
More informationInstallation Instructions
50ES, 50EZ, 50GL, 50GS, 50GX, 50JS, 50JX, 50JZ, 50SD, 50SZ, 50VL, 50VT, 50XP, 50XZ 601A, 602A, 602B, 604A, 604B, 604D, 607C, 701A, 702A, 702B, 704A, 704B, 704D, 707C PA1P, PA2P, PA3P, PH1P, PH2P, PH3P
More informationSwitch Disconnectors, Main and EMERGENCY-STOP Switches
General data Overview Siemens G 2010 1 2 3 NSE0_01931b 4 5 6 7 1 uxiliary switch (3SB for 3K; 3KX for 3KE) 2 IP20 terminal cover (Operator side) 3 3K switch disconnector 4 rcing contacts (only for 3KE)
More informationALLEGRO 'OPEN ROAD' NETWORK DIAGRAM
DRIVER ON 12V MTR OFF ON ENTRY STEP OFF 2013-2016 ALLEGRO 'OPEN ROAD' NETWORK DIAGRAM DCBR24-33 PANEL 1 2 3 4 5 6 CDC PANEL (no network connection) FRONT VIEW PARK PARK/ IGN IGN FUSED BATT 1 FUSED BATT
More informationANNEX A DRAWINGS. Technology and reliability that carries weight. Document Date Code Rev. Page
Technology and reliability that carries weight ANNEX A DRAWINGS. LD04 SYSTEM BLOCK DIAGRAM LD04/80/00. LD04 ENCLOSURE DIMENSIONS (ALUMINIUM/PLASTIC) LD04/80/00. LD04 ENCLOSURE DIMENSIONS (INOX) LD04/80/0
More informationSimple solutions for control technology
control and logic relays logic links instead of wiring 35.5 mm, 71.5 mm, and 107.5 mm wide DIN rail mounting Simple solutions for control technology logotron is a product family of convenient and easy
More informationPOWER Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free
Instruction Manual Model 1582-10M Protection Switch January 2009 Rev O ALARMS MENU OUTPUT = CH1 AUTO POWER 1 2 MODEL 1582 SWITCH CROSS TECHNOLOGIES INC. CH1 CH2 REMOTE EXECUTE Data, drawings, and other
More informationMAJOR VA Power Inverter
MAJOR500-500 VA Power Inverter The Major500 is a highly reliable, telecom quality, DC to AC power inverter. The Major500 features full electronic protection, high efficiency and low output noise. The built-in
More informationSTATUS Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free
Instruction Manual Model 1582-45L Data Switch September 2010, Rev A REMOTE LOCAL SWITCH STATUS SELECT REMOTE LOCAL LOCAL SELECT CHANNEL SELECT POWER MODEL 1582 SWITCH CROSS TECHNOLOGIES, INC. Data, drawings,
More informationNV1000 Terminal Equipment Operations Manual Introduction. Manual Part No. MI February, 1996
Nvision@ NV1000 Terminal Equipment Operations Manual Introduction CONTENTS 1. MANUAL DESCRIPTION 2. OVERVIEW 3. POWER AND THERMAL CONSIDERATIONS 4. INSTALLATION Manual Part No. MI1000-01 February, 1996
More informationDatasheet - MZM 100 B ST-1P2PW2REM-A
19.07.2016-15:57:28h Datasheet - MZM 100 B ST-1P2PW2REM-A Solenoid interlock / MZM 100 Preferred typ Actuator monitored Automatic latching Solenoid interlocks (for the protection of man) with innovating
More informationNew Solutions. for AC Motor Starters
ADAPTABILITY RELIABILITY CREATIVITY New Solutions for AC Motor Starters Featuring : Electronic Centrifugal Switches for Capacitor Start (Capacitor Run) Motors / Digital Motor Starters for Three Phase Bidirectional
More informationW6903 FI US. Outer casing
W6903 FI US Outer casing 101 107 108 106 109 105 135 133 134 138 136 137 110 111 127 116 114 131 121 122 112 115 139 114 140 123 119 ASKO, W6903 FI US - FI (WM60.3) Pos Spare part No. Description Qty Comment
More informationDrawn by Matthew Fox & Peter Vieira. Revised by Andrew Geck. Drawing List LEGEND. DC Power. AC Power. Control/DAQ. Current Transformer
LEGED DC Power AC Power Control/DAQ Current Transformer DC Circuit Breaker Circuit Breaker w/ Shunt Trip and AUX Feedback Disconnect / Switch Fan (Axial) Drawn by Matthew Fox & Peter Vieira Fuse ormally
More informationABB DC drive DCS800-A 18 A to 9800/19600 A
ABB DC drive 18 A to 9800/19600 A Enclosed converters Standard Features Flexible and modular hardware structure Line-ups and stand-alone cabinets Integrated automation system available 6- and 12-pulse
More informationDatasheet - SLB 200-C04-1R
14.02.2013-17:06:30h Datasheet - SLB 200-C04-1R Safety light barriers / Safety monitoring modules to monitor safety light barriers / SLB 200-C Up to 2 light barrier pairs SLB 200 can be connected 1 safety
More informationSD250 VARIABLE SPEED DRIVE
VARIABLE SPEED DRIVE SD250 Ranging from 0.4kW to 22kW, 200-230V and 380-480 Vac Easy programming and monitoring through cursors and digital display, removable up to 5m Wide range of accessories: RFI filter,
More informationQUINT-PS/ 1AC/24DC/20/CO
Extract from the online catalog QUINT-PS/ 1AC/24DC/20/CO Order No.: 2320898 DIN rail power supply unit 24 V DC/20 A/CO, dip-coated circuit board, primary-switched, 1-phase. For the first time, SFB (selective
More information////// SUBSTATIONS. DC Switchgear Range. Type MBS (IEEE/ANSI standards)
////// SUBSTATIONS DC Switchgear Range Type MBS (IEEE/ANSI standards) GENERAL INFORMATION With a complete range of equipment and a leading expertise in DC traction power substations, Sécheron SA is a world
More informationTeSys IEC Contactors and Overload Relays
TeSys IEC Contactors and Overload Relays Making High-Fault Short-Circuit Current Ratings Simple Schneider Electric is an industry leader in IEC contactors and overload relays, and is recognized as the
More information3500/15 Power Supply. Description
3500/15 Power Supply Description The 3500 Power Supplies are half-height modules and must be installed in the specially designed slots on the left side of the rack. The 3500 rack can contain one or two
More informationac wave 2 supply ( analog device )
ac wave 2 supply ( analog device ) «SPECIFIC PRODUCT SECTION» Instruction and user s manual Release 2.1 00/05 REEL S.r.l. Electronic Power Drives Via Riviera Berica, 42 36024 Ponte di Nanto - Vicenza -
More informationTME Modular Series UPS System kva/kw - 208/220 VAC
GE TME Modular Series UPS System 15-90 kva/kw - 208/220 VAC TME Modular Series UPS 15-90 kva/kw Highest Technology with Modular Design GE s TME Series UPS is one of the most reliable three-phase UL UPS
More informationEnclosed Power Supplies
, 15 150 Watt Features Very compact metal cased power supplies High operating temperature up to 70 C Low no load power consumption
More information3500/15 Power Supply Bently Nevada* Asset Condition Monitoring
3500/15 Power Supply Bently Nevada* Asset Condition Monitoring Description The 3500 Power Supplies are half-height modules and must be installed in the specially designed slots on the left side of the
More informationM C. Ex d M-0... control, monitoring and signalling devices
Ex d M-0... control, monitoring and signalling devices M-0 M-0 series control, monitoring and signalling devices are installed as external accessories on Cortem 'Ex d' enclosures used in any industrial
More informationSCS AUTOMATION & CONTROL
- 1 - SCS AUTOMATION & CONTROL PROJECT XXXX Issue A Winder Customer: XXXXXXX Ltd.. Automation Center 156 Stanley Green Road Poole Dorset England BH15 3AH - 2 - Contents 1. Introduction 2. Safety 3. Specification
More informationB100 Installation Manual
Installation Manual Description The provides an additional voltage in a FlexPower system. This voltage can either be accessed directly via the 's terminals or through other FlexPower Accessory Boards.
More informationMechanically Activated Device for Dry Run Protection in Applications with LORENTZ Solar Pump Systems
Well Probe Mechanically Activated Device for Dry Run Protection in Applications with LORENTZ Solar Pump Systems The switch can be used to detect the water level within a well. When the water level in the
More informationEaton s SPD Series for integration into electrical distribution equipment
Technical Data TD01006E Supersedes August 2009 Eaton s SPD Series for integration into electrical distribution equipment Contents Description Page Introduction....2 Applications....2 Features....2 Standards
More informationATV71EXA2C71N4 enclosed variable speed drive ATV71 Plus kw - 400V - IP23
Product data sheet Characteristics ATV71EXA2C71N4 enclosed variable speed drive ATV71 Plus - 710 kw - 400V - IP23 Main Range of product Product or component type Device short name Product destination Product
More informationFeaturing Spectra RMS Breakers
8000-Line Motor Control Centers Featuring Spectra RMS Breakers Fully integrated capabilities make GE your complete motor control center supplier Order management Coordinated drawings Applications support
More informationUSER S MANUAL. DAS-G01 The Power of Tomorrow
USER S MANUAL DAS-G01 The Power of Tomorrow Richmond Heights 2018 0 USER S MANUAL DAS-G01 The Power of Tomorrow Richmond Heights 2018 Page 1 USER'S MANUAL TABLE OF CONTENTS Page # 1.0 GENERAL INFORMATION...
More informationSpending too much to maintain aging switchgear? Circuit breaker solutions from Square D Services.
Spending too much to maintain aging switchgear? Circuit breaker solutions from Square D Services. Spending too much time and money on equipment maintenance? Square D Services: Your source for circuit breaker
More informationSafety switches with manual mechanical delay and separate actuator
D Safety switches with manual mechanical delay and separate actuator Selection diagram VF KEYF VF KEYF1 VF KEYF VF KEYF VF KEYF7 VF KEYF ACTUATORS MECHANICAL DELAY C L L0 Short knob 0 sec. Short knob sec.
More information(1986; Rev. 1989) Molded Case Circuit Breakers and Molded Case Switches. (1985; Rev. 1988) Enclosures for Electrical Equipment (1000 Volts Maximum)
Section 16306 50/60-HERTZ (HZ) SOLID STATE FREQUENCY CONVERTER Index PART 1 GENERAL PART 2 PRODUCTS 1.1 References 2.1 Frequency Converters 1.2 Factory Tests 2.2 Conduit and Fittings 1.3 Submittals 2.3
More informationC E R T I F I C A T E O F C O M P L I A N C E
LG Frame, Types NLGB, HLGB and LLGB. These are two and three pole circuit breakers with non-interchangeable thermal magnetic and electronic trip units. They are uncompensated 40 o C construction rated
More information3a. IEM Indoor Metal Clad Medium Voltage Switchgear 25KV a. Section INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std.
3a. IEM Indoor Metal Clad Medium Voltage Switchgear 25KV 16346-1 3a. Section 16346 INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std. Relays) Part 1 General 1.1 CONDITIONS AND REQUIREMENTS: A. Refer to
More informationMagnetically Actuated Safety Interlock Switches
Rev. 7.07 C US Conforms to EN1088, EN292, EN6020-1 CSA approved MA Series Magnetically Actuated Safety Interlock es Large selection choose from a large selection of contact configurations housed in plastic
More informationQUINT-PS/ 1AC/24DC/ 5
Extract from the online catalog QUINT-PS/ 1AC/24DC/ 5 Order No.: 2866750 DIN rail power supply unit 24 V DC/5 A, primary switched-mode, 1- phase. The SFB technology (Selective Fuse Breaking Technology)
More informationHDP5000 (2008 & 2013) Card Printer SPARE PART LIST. S rev 4.4. April HID Global Corporation/ASSA ABLOY AB. All rights reserved.
15370 Barranca Parkway Irvine, CA 92618 HDP5000 (2008 & 2013) Card Printer SPARE PART LIST S000565 rev 4.4 April 2014 2014 HID Global Corporation/ASSA ABLOY AB. All rights reserved. All rights reserved.
More informationOTPC 150/225/260 Amp Transfer Switch
OTPC 50/5/60 Amp Transfer Switch Printed in U.S.A. 6 08B (Spec A) 5-00 This catalog covers models produced under the Cummins /Onan and Cummins Power Generation brand names. To avoid errors or delay in
More informationHDP5000 (2008 & 2013) Card Printer SPARE PART LIST. S rev 4.4. April HID Global Corporation/ASSA ABLOY AB. All rights reserved.
15370 Barranca Parkway Irvine, CA 92618 HDP5000 (2008 & 2013) Card Printer SPARE PART LIST S000565 rev 4.4 April 2014 2014 HID Global Corporation/ASSA ABLOY AB. All rights reserved. All rights reserved.
More informationTechnical Service Bulletin Millennium/Paragon Emergency PLC Bypass Procedure
Technical Service Bulletin 040507 Millennium/Paragon Emergency PLC Bypass Procedure This service bulletin applies to Comark DCX Millennium and DCX Paragon transmitters. This bulletin provides a procedure
More informationElectrical Specifications VAC/390 VDC, Universal (Derate from 100% at 100V AC to 77% at 80V AC)
180 Watt Industrial Features 4 x 2 x 0.75 Inches Form factor 180 Watts with Forced Air Cooling Efficiencies upto 92% -40 to 70 degree operating temperature* 12V / 0.5A Fan Output, Thermal Shut-Down feature
More informationLiebert AccuVar (ACV Series) Surge Protective Device (SPD) (With Noise Filtering) GUIDE SPECIFICATIONS for a Parallel Surge Suppression System
Liebert AccuVar (ACV Series) Surge Protective Device (SPD) (With Noise Filtering) GUIDE SPECIFICATIONS for a Parallel Surge Suppression System Part 1 General 1.01 Summary A. These specifications describe
More informationSurge Protective Devices. STV25K Series. Instruction Manual
Surge Protective Devices STV25K Series Instruction Manual Contents 1.0 Installation & Operation... 4 1.1 Environment... 4 1.2 Mechanical Dimensions... 4 1.3 DIN Rail Mounting... 5 1.4 Supplemental Enclosures...
More informationFlush Mount SIP Access Control Intercom Installer s Guide
Flush Mount SIP Access Control Intercom Installer s Guide This step-by-step guide will help you install your Wahsega Labs flush mount SIP access control intercom. What s in the Box A. (1) VoIP intercom
More informationSummit Virtual Chassis Design and Installation Guide
Summit Virtual Chassis Design and Installation Guide Extreme Networks, Inc. 10460 Bandley Drive Cupertino, California 95014 (888) 257-3000 http://www.extremenetworks.com Published: June 1998 Part No: 120031-00
More informationSED2 VFD NEMA Type 3R Bypass/Air Conditioner
SED2 VFD NEMA Type 3R Bypass/Air Conditioner Description The NEMA Type 3R Bypass with Air Conditioner allows SED2 to be employed in a harsh environment. The SED2 is designed specifically for HVAC applications
More informationUser s Manual. ACS550-PD Stock 3R Irrigation Packaged Drive Supplement to ACS550-U1 User s Manual
User s Manual ACS550-PD Stock 3R Irrigation Packaged Drive Supplement to ACS550-U1 User s Manual 2 ACS550-PD 3R Irrigation Packaged Drive ACS550 Drive Manuals GENERAL MANUALS ACS550-U1 User s Manual (1
More informationCisco MCS 7815-I2. Serviceable SATA Disk Drives
Data Sheet Cisco MCS 7815-I2 THIS PRODUCT IS NO LONGER BEING SOLD AND MIGHT NOT BE SUPPORTED. READ THE END-OF-LIFE NOTICE TO LEARN ABOUT POTENTIAL REPLACEMENT PRODUCTS AND INFORMATION ABOUT PRODUCT SUPPORT.
More informationIs the Product correctly plugged?
Is the Product correctly plugged? YES NO Make sure the line cable is connected properly to the plug. Check the good working condition of the plug. Is it ok? NO Read Chapter 0 NO Do Fans operate for Less
More informationPARTS. WARNING: Use of non-midway parts or circuit modifications may cause serious injury or equipment damage! Use only Midway authorized parts.
2))52$' 7+81'(5TM &+$37(5 PARTS WARNING: Use of non-midway parts or circuit modifications may cause serious injury or equipment damage! Use only Midway authorized parts. For safety and reliability, don
More informationLightning & Surge Protection
Watchful Eye olutions, Inc. WTH-300, WTH-500/... Class I eries Lightning & urge rotection www.watchfuleyesolutions.com The Guardian that rotects Your AC ower upply ystem against urge and Lightning WTH-300/G
More informationRT12-240V/2.4kW Rectifier Specification
The RT12-240V/2.4kW is a switched mode rectifier (SMR) module that delivers up to 2.4kW of output power (and up to 11A output current) into a 240V nominal DC system. The RT12 suits AC supply voltages between
More informationUBI EasyCoder 101 Spare Parts Catalogue
CONTENTS Description Page Contents... Spare Parts Policy... 2 Front Panel, Outside View... 3 Front Panel, Inside View... 4 Right-Hand Door... 5 Rear Panel... 6 Bottom Plate... 7 Chassis Assy.... 8 Edge
More informationProduct Description. Table of Contents
Product Providing users with easy installation in mechanical fan and pump systems, the Allen-Bradley PowerFlex 400 AC drive offers a wide range of built-in features allowing for seamless building system
More informationThe following design principles were used to create the system. 1. Safety Please refer to the following Section Safety Precautions.
Lane Hardware Manual Introduction The Computer Score DVS Hardware Model is the fourth generation of Tenpin Bowling Scoring Equipment developed by Computer Score. The system that has been created around
More informationSH-7030 Specification DC to DC Converter
Compact and silent power solution for mini ITX SH-7030 Specification DC to DC Converter Rev. 1.0 Page 1 of 8 Contents 1.0 GENERAL 2.0 INPUT CHARACTERISTICS 2.1 INPUT VOLTAGE 2.2 INPUT CURRENT 3.0 OUTPUT
More informationSwitch rated plugs and receptacles with NEMA 4X protection
DSN Features and Ratings p. 22 DSN20 p. 23 DSN30 p. 25 DSN60 p. 27 Spare parts p. 29 Dimensions p. 31 21 Switch rated plugs and receptacles with NEMA 4X protection DSN Series products are switch and hp
More informationL.V. Systems & Solutions
GE Energy Industrial Solutions L.V. Systems & Solutions Residential Components & Distribution Boards Home & Building Automation Industrial Breakers General Purpose Enclosures System Enclosures Control
More informationProduct brochure. Cyberex. SuperSwitch 3 technology A digital static transfer switch
Product brochure Cybere SuperSwitch 3 technology 200 4000A digital static transfer switch SuperSwitch 3 technology 200 1000A SuperSwitch3 redefines reliability Forty years ago, Cybere revolutionized power
More informationSLI 15 Inverter Series Data Sheet 1500 Watt, 1U Compact Inverters
Applications Telecom IT Industrial Safety in compliance with IEC60950:1999, 3 rd edition; EN60950:2000; UL60950, 3 rd edition; CSA Standard C22.2 No.60950-00, 3 rd edition Features New, compact design:
More informationCONTROL PANEL WIRING SPECIFICATIONS
CONTROL PANEL WIRING ISSUE STATUS FIRST REV DESCRIPTION DATE 001 1 ST ISSUE 22/04/2014 002 1 ST AMMENDMENT 10/03/2017 003 2 ND AMMENDMENT 08/09/2017 THIS DOCUMENT IS DESIGNED TO COVER ALL APPLICATIONS,
More informationCircuit Breakers Type CTI 25M, CTI 45MB
Data sheet Circuit Breakers Type CTI 25M, CTI 45MB Circuit breakers for short circuit and overload protection of motor applications cover the current range 0.1 45 A (AC-3 rating). The product range is
More information