Distribution blocks Distribution
|
|
- Toby Fowler
- 6 years ago
- Views:
Transcription
1 blocks The solution for nclosures & accessories repar_008_a_1_cat > lectrical distribution Unipolar distribution blocks Conformity to standards blocks for SOCOMC disconnection devices repar_028_a_1_cat > IC > NF C Multipolar distribution blocks Function SOCOMC distribution blocks allow easy connection of conductors. They are installed downstream of a load break switch, a changeover switch or a fuse-combination switch. Characteristics General characteristics Insulation voltage: - ferrules terminal distribution block: 500 V, - modular row terminal distribution block: 690 V, - wire-terminal distribution block: 1000 V. Impulse voltage: - ferrules terminal distribution block: 6 kv, - modular row terminal distribution block: 6 kv, - wire-terminal distribution block: 8 kv. Self-extinguishing: 960 C. Composition of the range 7 ratings from 80 to 360 in 1, 2, 3 and 4 poles. 2 connection modes: - direct or ferrules, - cable lugs. 586 General Catalogue
2 blocks irect or cable connection ridge multipolar distribution block ating () Monoblock multipolar distribution block poles No of feeders per section (mm 2 ) x W x (mm) I cc (k rms) (1) 125 3/4 2x25 + 7x10 85 x 88 x /4 2x25 + 2x16 + 9x10 85 x 129 x /4 1x35 + 3x25 + 8x16 (2) 90 x x (1) Short circuit withstand (rms value) 1 second. (2) Maximum section of flexible cable. ating () (mm) W (mm) (mm) ating () poles x W x (mm) x 74.5 x x 71.5 x Unipolar distribution blocks ating () Switch mounting N (mm) I cc (k rms) escription of accessories Connection for rating 250 (1) Connection for rating 400 (1) (1) Linking part enabling direct assembly on the connecting lugs of the switching device. ating () x W x (mm) I cc (k rms) (1) x 27 x x 27 x x 45 x x 45 x x 45 x (1) Short circuit withstand (rms value) 1 second. Connections ating () ower supply section (mm 2 ) No of phases per section (mm 2 ) 80 < 16 4 x x < 35 6 x 2.5 to x 2.5 to x x x x x x hase: 5 x 1 to x 1.5 to 10 / Neutral: 6 x 1.5 to x 1.5 to x 2.5 to 16 arth bar Mounting No of feeders per W To be ordered in by section (mm 2 ) Material (mm) multiples of 2 self M4 10 x x 35 brass self M6 41 x x 35 brass W irect or cable connection distribution blocks which can be clipped onto a symmetric IN rail. ø W (1) irect or cable connection distribution blocks, I20 which can be clipped onto a symmetric IN rail. 32 barre_006_a_2_cat repar_010_c_1_gb_cat repar_008_a_2_cat repar_039_a_1_cat repar_009_a_1_gb_cat repar_027_a_2_cat General Catalogue
3 blocks ow distribution blocks ow distribution block with I20 connectors ating () Length With connector leads (1) Icc (k rms) 250 (2) 1 row yes (2) 1 row no repar_028_a_2_cat (1) elivered with 6 mm 2 connector leads, L = 120 mm, 12 black connectors, 12 blue connectors. (2) referably the terminations will be distributed over the entire number or terminals. Cables and connectors ating Length To be ordered in () Type (mm) Colour multiples of 40 6 mm 2 cable 120 lue mm 2 cable 120 lack mm 2 cable 320 lue repar_029_a_1_x_cat 40 6 mm 2 cable 320 lack mm 2 cable 320 lue mm 2 cable 320 lack mm 2 connector mm 2 connector General Catalogue
4 blocks Terminal connections Multipolar distribution blocks ating () poles Icc (k rms) No of feeders per section (mm 2 ) x x x x x x x x x x x x x x x x repar_007_b_1_cat ating () poles J K ØL T ØX ØX1 Y = = Ø X 8 x Ø X1 K lug-in unit for 5 to 6.3 mm bars repar_004_b_1_x_cat = J = = = Ø L Terminal connections distribution blocks with front protection cover against direct contact. T Y ating () poles 125/ / / / / / Max. 9 1 MIN 24 MX ating () poles C F G 125/ M / M / M / M / M / M ØC G F 1. ropper busbar with a thickness of 5 to 6.3 mm. 3 sb_186_a_1_x_cat General Catalogue
5 blocks Terminal connections (continued) Stair type multipolar distribution blocks ating () L (mm) poles Icc (k rms) block rotection cover supports Type ack qty Spacer for protection cover ating () Nb of terminations Ø L ø 25 L 140 ø M Stair type distribution blocks with threaded holes. Can be clipped onto a symmetric IN rail. Factory assembled and supplied without protection cover repar_012_b_1_cat repar_040_a_1_x_cat isconnectable solid neutral links ating () Connection type 160 Terminal connections N Terminal connections N Terminal connections N Terminal connections N repar_030_a_2_cat ating () C Width max. (mm) C shunt_012_a_1_x_cat 590 General Catalogue
6 blocks SICO multipolar distribution blocks ating () poles Icc (k rms) No of feeders per section (mm 2 ) x x x x x x x x x x x x x x x x repar_020_b_1_cat ating () poles K T Y K T Y repar_003_c_1_x_cat Terminal connections distribution blocks with front protection cover against direct contact (breaking device not supplied). Multipolar distribution blocks for FUSLOC and SICO VM2 ating () Fuse size poles evice No of feeders per section (mm 2 ) 100/125/160 22x58/00 3 FUSLOC 10x16 + 2x35 + 3xM /125/160 22x58/00 4 FUSLOC 10x16 + 2x35 + 3xM FUSLOC 10x16 + 2x35 + 3xM FUSLOC 10x16 + 2x35 + 3xM FUSLOC 11 x M FUSLOC 11 x M FUSLOC 11 x M (1) FUSLOC 11 x M (1) 160/200 3 SICO VM2 10x16 + 2x35 + 3xM /200 4 SICO VM2 10x16 + 2x35 + 3xM (1) xternal distribution block only compatible avec Fuserbloc rating 400 and reference 3xxx xx39. repar_013_a_2_cat ating () poles evice K T Y 100/125/160 3 FUSLOC /125/160 4 FUSLOC K FUSLOC FUSLOC FUSLOC FUSLOC FUSLOC FUSLOC /200 3 SICO VM /200 4 SICO VM Y T repar_041_a_1_x_cat General Catalogue
References. References. Rating (A) Référence
DIRECT OPERATION T O O R D E R EXTERNAL OPERATION picto_080_c_1_gb Switch body Direct Switch body + handle + Shaft + + OTHER ACCESSORIES External handle acces_128_a_1_cat acces_129_a_1_cat Direct handle
More informationPan assemblies and installation accessories
Contents Section 10 Pan assemblies and installation accessories SP&N pan assemblies 124 SP&N door and cover 124 TP&N pan assemblies 125 TP&N door and cover 125 Multiclip busbar and Polybloc 126 Comb busbars
More information63 to 125 A. Functions. Conformity standards. General characteristics. Changeover switches SIRCO VM1 changeover switches.
comut_004_a_1_cat Changeover switches switches 63 to 125 A switches are manually operated three or four pole switches. They provide, source inversion or switching under load between two low voltage power
More informationDisconnect Switches. Safe Switching and Disconnecting
IB105-UK_U1_U4_Pfade.indd 2-3 14.04.2005, 16:51:30 Disconnect Switches Safe Switching and Disconnecting Disconnect Switches from Salzer are hand-operated switchgear for main circuits and are offered as
More informationK1F037MCH cam voltmeter switch - 3L and 3L-N A - for Ø 22 mm
Characteristics cam voltmeter switch - 3L and 3L-N - 60-12 A - for Ø 22 mm Main Range of product Product or component type Component name [Ith] conventional free air thermal current Mounting location Fixing
More informationModular Terminal Blocks and Terminal Strips with CAGE CLAMP, Series 260 to 262, Side-Entry
36 Modular Terminal Blocks and Terminal Strips with CAGE CLAMP, Series 260 to 262, Side-Entry Assembly Assembly of modular terminal blocks to terminal strips Mounting of an end plate screw fixing CAGE
More informationIDE Load break switches for machine control Remotely trippable switch from 32 to 160 A
The solution for Load break switches > Industry. > Non critical buildings. > Public Access Sites. > High Rise Buildings. ide_021_a_1_cat ide_022_a_1_cat IDE 4x40 A External operation IDE 4x40 A Direct
More informationK1D004ACH cam switch - 4-pole A - for Ø 22 mm
Characteristics cam switch - 4-pole - 45-12 A - for Ø 22 mm Main Range of product Product or component type Component name [Ith] conventional free air thermal current Mounting location Fixing mode Cam
More informationHorizontal distribution busbar HX 3 80/125 A plug-in
87045 LIMOGES Cedex Telephone: +33 5 55 06 87 87 FAX: +33 5 55 06 88 88 Horizontal distribution busbar HX 3 CONTENTS Pages 1. Description... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation -
More informationElectrical Connection Technology. New Items: Autumn 2007
Electrical Connection Technology New s: Autumn 2007 Contents Rail-Mounted Terminal Block Systems Volume 1 02 57 PCB Terminal Blocks and Connectors Volume 2 58 91 WINSTA WINSTA 93 97 Index of Nos. 98 102
More informationFUSERBLOC UL Fusible disconnect switches UL and CSA 30 to 800 A
Fuse protection The solution for > Motor load break. > Protection of industrial cabinet. > Electrical distribution. ul_004_a Strong points fuser-ul_006_a Function FUSERBLOC UL fusible disconnect switches
More informationK1D012ULH cam changeover switch - 2-pole A - screw mounting
Characteristics cam changeover switch - 2-pole - 90-12 A - screw mounting Main Range of product Product or component type Component name [Ith] conventional free air thermal current Product mounting Fixing
More informationContactors and Contactor Assemblies
RT contactors, size S00 The product range at a glance The new generation is a complete, modular system family, logically designed right down to the last detail, from the basic units to the accessories.
More informationC60PV-DC. IEC / EN e. Main characteristics Operating voltage (Ue) 800 V DC Rated insulation voltage (Ui) 1,000 V DC Breaking capacity (Icu)
DC circuit supplementary protectors for photovoltaic C60PV-DC PB108403-50 The C60PV-DC is a DC circuit breaker dedicated to multi string photovoltaic. This circuit breaker is designed to protect the cables
More informationfor a perfect electrical installation. The range of rail-mounted terminal blocks
The range of rail-mounted terminal blocks for a perfect electrical installation. The range of rail-mounted terminal blocks for a perfect electrical installation. The new standard for rail-mounted terminal
More informationK1C024B body for BCD encoded output switch - 1 pole A - for Ø 22 mm
Characteristics body for BCD encoded output switch - 1 pole - 45-12 A - for Ø 22 mm Main Range of product Product or component type Component name [Ith] conventional free air thermal current Sub-assembly
More informationFUSERBLOC UL Fusible disconnect switches UL and CSA from 30 to 800 A
Fuse protection The solution for > Motor on-load disconnect > Protection of industrial cabinet > Electrical distribution ul_004_a Strong points fuser-ul_006_a Function FUSERBLOC UL fusible disconnect switches
More informationict contactors EN 61095, IEC 1095 Interference
ict contactors DB23399 DB669 DB06604 Country approval pictograms EN 6095, IEC 095 ict contactors are available in two versions: b Contactors without manually-operated b Contactors with manually-operated.
More informationIssued February DATA SHEET 5SX2 MCB. Based on Siemens Industrial Control Catalog
Issued February 2011 DATA SHEET 5SX2 MCB Based on Siemens Industrial Control Catalog General Data Trip characteristics Tripping characteristics acc. to EN 60 898 Tripping characteristic A, -5 Type A characteristic
More informationK1F003MCH cam ammeter switch - 3 circuits A - for Ø 22 mm
Product data sheet Characteristics cam ammeter switch - 3 circuits - 90-12 A - for Ø 22 mm Complementary Main Range of product Product or component type Component name [Ith] conventional free air thermal
More informationMULTI-POLE PHOTOVOLTAIC SYSTEMS. COMPACT and MODULAR Housing
MULTI-POLE Lightning Current and Surge Arresters for PHOTOVOLTAIC SYSTEMS Class I / (B+C) and Class II / (C) COMPACT and MODULAR Housing 44 PV ISPRO BS(R) 12,5 The PV ISPRO BS(R) 12,5 series of over voltage
More informationK1B004TLH cam switch - 1 pole A - screw mounting
Characteristics cam switch - 1 pole - 30-12 A - screw mounting Main Range of product Product or component type Component name [Ith] conventional free air thermal current Product mounting Fixing mode Cam
More informationMotor protection relays
Thermal overload relays for currents between 0.09 and 420A Electronic thermal overload relays for currents between 0.4 and A Electronic thermal overload relays with selectable tripping class: 5--20-30
More informationNV disconnectors with fuses
NV disconnectors with fuses Horizontal fuse-switch disconnector type HVL size 00,, 2, and 4a Description Horizontal fuse-switch disconnector type HVL are designed to be used in most demanding fields of
More informationSOCOMEC SIRCOVER MANUALLY OPERATED CHANGEOVER SWITCHES
MANALL OPERATED CHANGEOER SWITCHES are manually operated multipolar changeover switches. They changeover between two low voltage power circuits under load and provide safety disconnection. Application:
More informationSIRCO Load break switches for power distribution from 125 to 5000 A
The solution for Load break switches sirco_456_a_1_cat > Main switchboard > Distribution panel > Emergency breaking > Network coupling > Local safety breaking sirco-ac_001_a_1_cat SIRCO 3 x 250 A direct
More informationPCB-COMPONENTS PCB-COMPONENTS CATALOGUE 2002/03 CATALOGUE 2002/03
2 PCB-COMPONENTS PCB-COMPONENTS CATALOGUE 2002/03 CATALOGUE 2002/03 CATALOGUE 2002/03 CATALOGUE 2002/03 Rated cross-section 1.5 2 LM 3.5/90 LM1N 3.5/90 LM 3.5/135 Rated cross-section 1.5 2 Technical Data
More informationPerformance. Standards. Technical data
ilos Loadbreak disconnectors for wall mounting ilos H up to ilos up to 5 ilos 4 0 up to Order codes pplications pprovals / Marking ilos H4 ilos H ddon devices Performance Wall mounting Main disconnector,
More informationSiemens AG SENTRON 3NJ4, 3NJ5 In-Line Fuse Switch Disconnectors up to 2000 A
Switch Disconnectors Introduction Overview All key product features at a glance Compliant with IEC/EN 60439-1, IEC/EN 6094-3 Voltage levels up to 690 V AC Rated operational current from 160 A to 2000 A
More informationPCB-COMPONENTS PCB-COMPONENTS CATALOGUE 2002/03 CATALOGUE 2002/03
2 PCB-COMPONENTS PCB-COMPONENTS CATALOGUE 2002/03 CATALOGUE 2002/03 CATALOGUE 2002/03 CATALOGUE 2002/03 Rated cross-section 10.0 2 GSE 10/180 LU 10.16/90 LU 10.16/90 with test point 4 solder pins per pole
More informationK1K015NZ4 cam stepping switch - 2-pole A - screw mounting
Characteristics cam stepping switch - 2-pole - 60-12 A - screw mounting Complementary Number of steps 5 Main Range of product Product or component type Component name [Ith] conventional free air thermal
More informationPCB-COMPONENTS PCB-COMPONENTS CATALOGUE 2002/03 CATALOGUE 2002/03
2 PCB-COMPONENTS PCB-COMPONENTS CATALOGUE 2002/03 CATALOGUE 2002/03 CATALOGUE 2002/03 CATALOGUE 2002/03 Rated cross-section 4.0 2 TOP4GS 7.62/90 TOP4GS 7.62/180 Technical Data VDE UL CSA Rated voltage
More informationK1D011B body for BCD encoded output switch - 1 pole A - for Ø 22 mm
Characteristics body for BCD encoded output switch - 1 pole - 30-12 A - for Ø 22 mm Complementary Main Number of decimal 11 Switching angle 30 Range of product Product or component type Component name
More informationR3&A Limited, Cobourg, ON
R3&A imited, Cobourg, ON ightning and Surge Protection Devices for North America Easy Choice POWER SUPPY SYSTEMS Main distribution board (Category C) Class I ightning current arrester Subdistribution board
More informationSwitches 6/1. 6/4 Introduction. 6/5 5TE8 control switches. 6/7 5TE4 8 pushbuttons. 6/9 5TE8 On/Off switches. 6/11 5TE1 switch disconnectors
6/4 Introduction 6/5 5TE8 control switches 6/7 5TE4 8 pushbuttons 6/9 5TE8 On/Off switches 4 6/11 5TE1 switch disconnectors 6 6/1 Switch to manual? Wherever electrical systems need to be switched on or
More informationApplication Switchgear for industrial and advanced commercial applications. U e V AC 240/ (per pole) I cs 7,5 ka
DATASHEET - FAZ-C16/1 Miniature circuit breaker (MCB), 16A, 1p, C-Char, AC Part no. FAZ-C16/1 Catalog No. 278561 Eaton Catalog No. FAZ-C16/1 EL-Nummer 0001695154 (Norway) Similar to illustration Delivery
More informationFUSERBLOC LMDC Fuse combination switches FUSERBLOC Live Maintenance DC
Fuse protection The solution for > Live maintenance of speed drives supplied by a common DC bus > Live maintenance of PV inverters connected in parallel on a same circuit fuser-lm_2_a Strong points > Compact
More informationK1F006ALH cam switch - 6-pole A - screw mounting
Characteristics cam switch - 6-pole - 45-12 A - screw mounting Complementary Main Range of product Product or component type Component name [Ith] conventional free air thermal current Product mounting
More information24973 Circuit Breaker MINIATURE CIRCUIT BREAKER, 440VAC, 10A, CIRCUIT BREAKER TYPE: STANDARD
United States 24973 Circuit Breaker MINIATURE CIRCUIT BREAKER, 440VAC, 10A, CIRCUIT BREAKER TYPE: STANDARD Image not available Product Information Features and Specifications Approvals: IEC 60947-2 Rated
More information8WH5 Combination Plug-In Terminals
8WH Combination Plug-In Terminals /2 Introduction / 8WH through-type terminals 1) /7 8WH hybrid through-type terminals with ipo connection /8 8WH9 plugs 1) 1) Also available as a PE version More technical
More informationData sheet... OMNIMATE Power - series BL/SL 7.62HP BLZ 7.62HP/04/180LR SN BK BX
Power on board #96 100% safety, 100% integration, 100% cost-effectiveness: The compact and efficient solution for UL-600V applications in the lower performance range (up to 12 kva). 29 A at 400V (IEC)
More informationMOTOR PROTECTION CIRCUIT BREAKERS
MOTOR PROTECTION CIRCUIT BREAKERS PAGE -2 PAGE -2 SMA Thermal trip adjustment ranges 9-32A (5 choices) Breaking capacity Icu at 400V: 50kA Suitable for mounting in consumer switchboards with minimum 58mm
More informationRCMB20/RCMB Series
4 T M /-500 Series Integratable Ground Fault Monitoring Modules For Integration Into Frequency Converters and Combiner Boxes Technical Bulletin NAE1042510 / 10.2012 BENDER Inc. 700 Fox Chase, Coatesville
More informationData sheet ACT20P ACT20P-CMT-10-AO-RC-S. Phone: Fax: Web: - [!
-CMT-10-AO-RC-S [!-] General ordering data Type -CMT-10-AO-RC-S Order No. 1510470000 Version Current-measuring transducer GTIN (EAN) 4050118319583 Qty. 1 pc(s). -CMT-10-AO-RC-S Technical data Dimensions
More information- 1 - General ordering data Order No
General ordering data Order No. 1727690000 Part designation B2L 3.5/16 SN SW Version EAN 4032248037889 Qty. 50 pc(s). PCB plug-in connector, Female connectors, Tension clamp connection, Clamping range,
More information09. DIN CONNECTORS
. 41 612 CONNECTORS Connectors that comply with 41 612 have been in use for years for both board-to-board applications and cable-to-board applications. Their robustness and universality are legendary.
More information- 1 - Product catalogue PCB connection systems PCB terminals Clamping yoke connection LM 5.00 / 5.08 LM 5.00/135
General ordering data Order No. 1715360000 Part designation LM5.00/3/135 OR Version EAN 4008190365240 Qty. 500 pc(s). PCB terminal, Clamping yoke connection, Soldered connection, Clamping range, max.:
More informationItem No.: /
mounting adapter also for DIN 35 rail; % protected against mismating; Plate thickness 06x12 mm; Male connector; with snap-in mounting foot; 4-pole; pin spacing 35 mm / 0138 in; with 209-137 mounting adapter
More informationPCB-COMPONENTS PCB-COMPONENTS CATALOGUE 2002/03 CATALOGUE 2002/03
2 PCB-COMPONENTS PCB-COMPONENTS CTLOGUE 2002/03 CTLOGUE 2002/03 CTLOGUE 2002/03 CTLOGUE 2002/03 Rated cross-section 1.5 2 LMZF 5.08/90 LMZF 5.08/135 LMZF 5.08/180 Rated cross-section 1.5 2 Technical Data
More informationReferences. For SIRCO MV. References
16 to 160 A Functions Dimensions sircm_071_b_1_x_cat Direct handle M00 handle sircm_041_a_1_x_cat M01 handle Handle colour Handle 16 80 100 125 Blue Blue M00-type M01-type 2299 5012 2299 5032 Handle colour
More information3RM1 Hybrid Starters 6SIRIUS. contents. Industrial Controls Product Catalog 2017
3RM1 Hybrid Starters Industrial Controls Product Catalog 2017 Section contents 3RM1 Compact - Hybrid Starters Overview /2 General Data /3 Selection and ordering data /4 Accessories /5 - /9 Technical Data
More informationTOPJOB S Sensor/Actuator Terminal Blocks with Push-in CAGE CLAMP Reliability
TOPJOB S Sensor/Actuator Terminal Blocks with Push-in CAGE CLAMP Reliability TOPJOB S SEND THE RIGHT SIGNALS. TOPJOB S Sensor/Actuator Terminal Blocks with Push-in CAGE CLAMP Reliability TWO IN ONE. WITH
More informationOTEC Miniature Circuit Breakers (MCB) OTEC Miniature Circuit Breakers (MCB) OTEC Miniature Circuit Breakers (MCB) Areas of Application
Miniature Circuit Breakers Areas of Application Miniature circuit breakers (MCBs) of the N-System primarily protect cables and conductors against overload and short circuit. Thus, they also protect electrical
More information3RT, 3TB, 3TF Contactors for Switching Motors
RT, TB, TF Contactors for Switching Motors Overview RT contactors and coupling relays Size S00 with mountable accessories The SIRIUS generation of controls is a complete, modular system family, logically
More informationContactors and Contactor Assemblies
SIRIUS Contactors and Contactor Assemblies Application WYE-delta starting can only be used either if the motor normally operates in a d (delta) connection or starts softly or if the load torque during
More informationNon-Fusible Disconnect Switches
UL 98 and IEC, Non-Fused Switches Mersen s non-fusible disconnect switches are listed to UL 98 and bear the CE mark as conformance to IEC 60947-3. They are service entrance devices that are capable of
More informationEXPANSION PERIPHERAL CVM-R10 C. (Code ) INSTRUCTION MANUAL ( M / 00 A ) (c) CIRCUTOR S.A.
EXPANSION PERIPHERAL CVM-R10 C (Code 7 70 217 ) INSTRUCTION MANUAL ( M 981 170 / 00 A ) (c) CIRCUTOR S.A. ------ CVM-R10 C Peripheral --------------- Pag. 1 CVM-R10C EXPANSION PERIPHERAL 1.- DESCRIPTION
More informationUL 98 Fusible Disconnect Switches
UL 98 Fusible Mersen s fusible disconnect switches are listed to UL 98 and bear the CE mark as conformance to IEC 60947-3. They are service entrance devices capable of fully rated load-break and load-make.
More informationRE Product data sheet Characteristics. time delay relay for star-delta starter ms - 230/380 V AC - 1 contact. Main.
Characteristics time delay relay for star-delta starter - 20..140 ms - 230/380 V AC - 1 contact Main Range of product Product or component type Contacts type and composition Component name Time delay type
More informationMiniature Push-Pull Series Atto Miniature Push-Pull
J Miniature Push-Pull Series Atto Miniature Push-Pull Technical Data Panel connector Cable connector Coupler connector Panel connector, cable connector and coupler connector circular housing Locking Push-Pull,
More informationTOPJOB S Sensor/Actuator Terminal Blocks with Push-in CAGE CLAMP Reliability
TOPJOB S Sensor/Actuator Terminal Blocks with Push-in CAGE CLAMP Reliability TOPJOB S SEND THE RIGHT SIGNALS TOPJOB S Sensor/Actuator Terminal Blocks with Push-in CAGE CLAMP Reliability TWO IN ONE. WITH
More information6/2 Product overview. 6/3 Lightning arresters, type 1. 6/5 Combination surge arresters, type 1 and type 2. 6/7 Surge arresters, type 2
iemens AG 2009 BETA rotecting Overvoltage rotection evices /2 roduct overview /3 Lightning arresters, type 1 /5 Combination surge arresters, type 1 and type 2 /7 urge arresters, type 2 /13 urge arresters,
More informationBETA Protecting Overvoltage Protection Devices
iemens AG 2008 BETA rotecting Overvoltage rotection evices /2 roduct overview /3 Lightning arresters, type 1 /5 Combination surge arresters, type 1 and type 2 /7 urge arresters, type 2 /13 urge arresters,
More information- 1 - General ordering data Order No
General ordering data Order No. 1730710000 Part designation BL 5.00/3 SN SW Version EAN 4008190387327 Qty. 100 pc(s). System parameters Conductor connection system Leaf spring connection Outgoing direction
More informationDX 3 MCB A / 16 ka 80 A to 125 A (1,5 module per pole)
87045 LIMOGES Cedex Telephone: +33 5 55 06 87 87 FAX: +33 5 55 06 88 88 DX 3 MCB 10000 A / 16 ka CONTENTS PAGES 1. Description - Use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection...
More informationRiLine Compact The smart power distribution system
RiLine Compact The smart power distribution system 2 Power distribution in a confined space Rittal are the leading suppliers of reliable power distribution and backup systems for controlgear. The new RiLine
More information- 1 - General ordering data Order No
General ordering data Order No. 1627280000 Part designation SLS 5.08/6B SN OR Version EAN 4008190199791 Qty. 50 pc(s). PCB plug-in connector, Male connectors, Clamping yoke connection, Clamping range,
More information60103 Circuit Breaker
6003 Circuit Breaker United States MINIATURE CIRCUIT BREAKER, 20/240VAC, 2A, CIRCUIT BREAKER TYPE: STANDARD Image not available Product Information Features and Specifications Circuit Breaker Type: Standard
More informationXCMD21F0L2 limit switch XCMD - M12 metal end plunger - 1NC+1NO - snap - 2 m
Characteristics limit switch XCMD - M12 metal end plunger - 1NC+1NO - snap - 2 m Complementary Switch actuation Electrical connection Cable length Cable composition Wire insulation material Contacts insulation
More informationElectrical Interconnection
Electrical Interconnection Edition 208/ Rail-Mount Terminal Block Systems Full Line Catalog, Volume Edition 207/208 PCB Terminal Blocks and Connectors Full Line Catalog, Volume 2 Edition 207/208 2 Automation
More informationENERGY SAFELY SWITCHED SWITCHGEAR. BUSBAR SYSTEM 60 mm
ENERGY SAFELY SWITCHED SWITCHGEAR BUSBAR SYSTEM 60 mm SWITCHGEAR ENERGY safely switched About Grupa Apator Who we are? Grupa Apator is a dynamic Polish capital group, it currently includes 14 companies
More informationVarius SUMMARY OF MODELS OF HRC FUSE-LINKS
SUMMARY OF MODELS OF HRC FUSE-LINKS PNA000 PHNA000 PNA00 PHNA00 Rated current I n up to A up to 0 A up to A up to 0 A Rated voltage U n AC 00 V, 00 V 90 V 00 V 90 V DC 0 V 0 V 0 V 0 V Fuse-link size 000
More informationEMS CX 3 - State and control module for Latching relays and Contactors
87045 LIMOGES Cedex Telephone : 05 55 06 87 87 Fax: 05 55 06 88 88 EMS CX 3 - State and control module Contents Pages 1. Description - Use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation -
More informationLow voltage. Acti 9. the efficiency you deserve. Catalogue 03/2016
Low voltage Acti 9 the efficiency you deserve Catalogue 03/2016 schneider-electric.com 1 and 2 LV surge s 1 and 2 LV surge s (cont.) The 1 range of surge s meets the normative withstand capability of wave
More informationLow voltage. NG to 160 A. Modular incoming circuit breakers and switch-disconnectors for DIN-panel installation.
Low voltage NG160 16 to 160 A Modular incoming circuit breakers and switch-disconnectors for DIN-panel installation Catalogue 2010 NG160 circuit breaker Ready to install NG160 General contents Presentation
More informationSolid State Remote Power Controller E
Description The E-T-A is a transistorised switching device providing both protection and signalisation. It is suitable for all applications where the capabilities of the existing PLC s are not sufficient
More informationUK 5-HESILA 250. Extract from the online catalog. Order No.:
Extract from the online catalog UK 5-HESILA 250 Order No.: 3004142 The illustration shows version UK 5-HESI Fuse terminal block for cartridge fuse insert, cross section: 0.2-4 mm², AWG: 26-10, width: 8.2
More informationModular surge protective devices (SPDs) Cat. Nos :
Contents Page 1. General characteristics...2 2. Overall dimensions...4 3. Technical characteristics...4 4. Conformity...9 5. Mounting...9 6. Accessories.............................11 Product information
More information02/11/2015
35 mm - 1 Relay 8A OUR1 Part number 88867105 Multi-function or mono-function Multi-range Multi-voltage Relay output 1 or 2 : 8 A - 250 V (10 A UL) LED status indicator Option of connecting an external
More informationFAZ Supplementary Protectors, FAZ Miniature Circuit Breakers, P2 Disconnect Switches Overview
FAZ Supplementary Protectors, FAZ Miniature Circuit Breakers, P2 Disconnect Switches Overview Supplementary Protectors / Miniature Circuit Breakers Page System overview 10/003 10/001 Supplementary protectors
More informationElectrical auxiliaries for ic60, iid, idpn Vigi, isw-na, RCA and ARA
for ic60, iid, idpn Vigi, isw-na, RCA and ARA b The electrical auxiliaries are combined with ic60 circuit breakers, iid residual current circuit breakers, remote tripping switch disconnector isw-na, RCA
More informationPRF1 12.5r/PRF1 Master/ PRD1 25r/PRD1 Master Type 1 and 2 LV surge arresters
Type 1 and 2 LV surge s The Type 1 range of surge s meets the normative withstand capability of wave type 10/350 μs (8/20 μs for Type 2 surge s). It is suitable for use with, TN-C and 230 V IT earthing
More informationDatasheet - AZ 15 ZVRK
24.12.2015-09:51:40h Datasheet - AZ 15 ZVRK Safety switch with separate actuator / AZ 15 Preferred typ Thermoplastic enclosure Double-insulated Long life 52 mm x 75 mm x 30 mm Multiple coding Large wiring
More informationMULTI 9 System Catalog UL Recognized C60N Supplementary Protectors
UL Recognized C60N Supplementary Protectors B Curve C60N Supplementary Protectors 1 MG24110 MG24125 MG24140 MG24155 15 MG17406 MG17436 MG17461 1.2 MG17402 MG17432 16 MG24118 MG24133 MG24148 MG24163 1.5
More informationlow voltage GLOBAL CATALOGUE RANGE Motor Control Contactors - Thermal Overload Relay s - Manual Motor Starters
CTLOGUE GLOBL RNGE 2. Motor Control Contactors - Thermal Overload Relay s - Manual Motor Starters 2. 2. Product Overview. 2.2 Overload Relay Setting Range 2. - 2.8 Product Specifications 2.9-2. Contactor
More informationThrough/Ground Conductor/Ex and Double-Potential Terminal Blocks 1 (1.5) mm, 2000 Series
54 TOPJOB @ Through/Ground Conductor/Ex and Double-Potential Terminal Blocks (.5) mm, 2000 Series 0.4 - (.5) mm I N 3.5 A (8 A) AWG 24-00 V, 0 AU 00 V, 0 A2 Terminal block width 3.5 mm / 0.38 in L 9 -
More informationModular surge protective devices (SPDs)
128, av. du Maréchal-de-Lattre-de-Tassigny - 87045 LIMOGES Cedex Tel : 0 (+33) 5 55 06 87 87 Fax : 0 (+33) 5 55 06 88 88 www.legrand.com Modular surge protective devices (SPDs) CONTENTS Page 1. General
More informationModular surge protective devices (SPDs)
128, av. du Maréchal-de-Lattre-de-Tassigny - 87045 LIMOGES Cedex Tel : 0 (+33) 5 55 06 87 87 Fax : 0 (+33) 5 55 06 88 88 www.legrand.com Modular surge protective devices (SPDs) CONTENTS Page 1. General
More informationPower distribution systems - accessories
Connections and terminals Line terminal X 221 3 01 Power-D-Box with sockets pre-wired Line terminal (max. 63 A) X 221 3 01 14.551 max. tightening torque 3.0 Nm 15.591 busbar X1, X2 blade terminals 6.3
More informationRM17UB3. Product data sheet Characteristics. voltage control relay RM17-U - range V AC. Main. Complementary
Characteristics voltage control relay RM17-U - range 183..528 V AC Main Range of product Product or component type Relay type Product specific application Relay name Relay monitored parameters Time delay
More informationSurge Protection Devices Type 1+2
Surge Protection Devices Type 1+2 Description The combined surge protection devices offer as an all-in-one solution lightning and surge-voltage in one device. They are in accordance with the requirement
More informationExtract from the online catalog
Please note that the data given here has been taken from the online catalog. For comprehensive information and data, please refer to the user documentation at http://www.download.phoenixcontact.com. The
More informationEMS CX 3 - State and control module for Latching relays and Contactors
LEGRAND - BP30076 87045 LIMOGES CEDEX FRANCE Telephone: 05 55 06 87 87 Fax: 05 55 06 88 88 Contents Pages 1. Description - Use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection...
More informationSUBMINIATURE MICROSWITCHES - SEALED
SWITCHES.COUZET.COM MICOSWITCHES SUBMINIATUE MICOSWITCHES - SEALED VS - 88 Coil spring snap-action mechanism Wire lead or cable outputs, various terminal types with symmetric or asymmetric pinning Excellent
More information02/11/2015
DIN Rail Mount 22.5 mm TU2R1 Part number 88865305 Product with 1 relays (88 865 100/103/105/115/125/135/145/155/185/503) : Replaced by the 17,5 mm range For instance : previous part number 88 865 XXX /
More information34 SERIES. Slim electromechanical PCB relays 6 A Ultra-slim 1 Pole - 6 A relay
34 Slim electromechanical PCB relays 6 34 Ultra-slim 1 Pole - 6 relay Printed circuit mount - direct or via PCB socket 35 mm rail mount - via screw, screwless or push-in terminal sockets 34.51 34.51-5010
More informationUK-SI. Extract from the online catalog. Order No.:
Extract from the online catalog UK-SI Order No.: 3118012 Fuse terminal block for cartridge fuse inserts 5 x 20 and 5 x 25, cross section: 0.2 -, width: 8.2 mm, color: black Commercial data EAN 4017918092856
More informationSR60 Busbar System 2/1 2/2. General Data. 2/3 Busbar routing. 2/7 Mounting components. 2/13 Accessories
/ SR0 Busbar System General Data / Busbar routing / Mounting components / Accessories / SR0 Busbar System General Data Overview The SR0 busbar system is a modular system for busbars, for installation in
More informationENERGY /// TE'S CROMPTON INSTRUMENTS TE'S CROMPTON INSTRUMENTS CURRENT TRANSFORMERS
ENERGY /// TE'S CROMPTON INSTRUMENTS TE'S CROMPTON INSTRUMENTS CURRENT TRANSFORMERS 2 ENERGY /// TE'S CROMPTON INSTRUMENTS 3 Table of contents I. Tape Wound Measuring and Protection Current MR Series Measuring
More informationOvervoltage Protection Devices
Siemens AG 2010 Overvoltage Protection Devices /2 Introduction /3 Lightning Arresters, Type 1 /5 Combination Surge Arresters, Type 1 and Type 2 /7 Surge Arresters, Type 2 /11 Surge Arresters, Type 3 /12
More information