Option. AR-701B-X Fit 35mm DIN Rail or Mount directly AR-721K AR-725K AR-331K 1456 RAM. WG 26 / WG 34 Power Supply. YES Power Consumption
|
|
- Gervase Manning
- 5 years ago
- Views:
Transcription
1 SOYAL ACCESS CTROL SYSTEM AR-E V0 Contents Product User Guide Panel Mounting Base WG Key-panel Reader Option AR-0B-X Fit mm DIN Rail or Mount directly AR-K AR-K AR-K Option For Stand-alone Command Setting Specification CPU bit CPU Temperature -0 ~ +0 Event log RAM k Bits Digital Input Door Open Button/ Door Sensor/ Housing open detection/ Prepared for DI Aux. WG Port WG / WG Power Supply 0 ~ Relpy Output Door Relay/ Alarm Relay/ Prepared for Relay output Anti-pass-back YES Power Consumption < W Transistor Output Prepared for DO Lift Control NO Interface RS- Door Relay Time Toggle, 0.~00Ses Time Zone (stand-alone /networking) Baud Rate 900 bps, N,, Alarm Relay Time Toggle, 0.~00Ses Real Time Clock YES External WG Readers WG (Controller power supply) User Capacity,000 DIP_SW (Node ID: ~) Connector Table P P 0 9 Dip-switch 0 9 Node ID is setting by DIP_Switch, Node ID: 0~ Value DIP SW Node 0 Node 0 Node 0 Node Node ~ OUT DO OUT ALM P P P Connector: P RS- / Power LA+ LB- DC RS-(A+) RS-(B-) DC Power 0V DC Power Connector: P WG Port OUT TAM () SEN () PB () WG 9 0 / Beeper Output LED Green Output LED Red Output Tamper Switch Input Door Status Input Exit Button Input Wiegand DAT: Input Wiegand DAT:0 Input DC Power Output Connector: DI DI P Digital Input Pin DI Fire-alarm Input Connector: P Relay / Alarm Output DO ALM / / Connector: P WG Port OUT PB () SEN () TAM () WG 9 0 / LED Red Output LED Green Output Beeper Output Exit Button Input Door Status Input Tamper Switch Input Wiegand DAT:0 Input Wiegand DAT: Input DC Power Output Connector: DO DO Transistor Output DO DO Wiring Diagram P AR-H Connect to PC P Connect to Alarm or Other Converter B- A+ DC DC AR-E P 0V B- A+ ALM DO AR-E P Alarm
2 Door WG Controller V0 P AR-H Connect to Electric Strike P Connect to Magnet Lock or Electric Bolt Tamper Switch Electric Strike DC Tamper Switch Magnet Lock or Electric Bolt DC Reader A WG WG Door Sensor EXIT WG 0 WG Reader B 0 9 Door Sensor EXIT P AR-H About Digital Input WG PB SEN TAM LR LG AR-E P OUT Push Button WG TAM SEN PB AR-E P About Transistor Output OUT Push Button If the Power line more than 00 m between the Controller and Reader, it is recommended NOT to use the "Wiegand Power". See connection mode within the dashed box, Controller and Reader must to do "common--point". Relay Output Module CTL DI DI AR-E P Relay Output Module DC CTL DO AR-E P All commands below are only able to set up by connected with WG key-panel reader. Adding and Deleting Tag Add Single Tag or Random tags Input (or Master ) 9 UUUUU 0000 Present the tag(s) with reader (single tag or random numbered cards one by one) Done [e.g.] readom cards with user addresses No. 00 and No. 0: Access programming mode Present the tags one by one Done Add the Sequential tags Input (or Master ) 9 UUUUU QQQQQ Present the tags (Present the tag with the lowest number first.) OK [e.g.] User Address NO.0 to NO.0 have 0 pcs of sequential tags:(~): Access programming mode Close Tag into RF Area(only use the tag NO.) OK Delete a Single Tag Input (or Master ) 0 SSSSS 9 EEEEE [e.g.] Delete User Address: 000 Access programming mode Delete a batch of Tags Input (or Master ) 0 SSSSS 9 EEEEE [e.g.] Delete User Address: 000~00 Access programming mode Operation process Delete All Tags Input (or Master ) 9 9 Tag Information CARD CODE SITE CODE A. Enter/ Exit Program Mode Enter the program mode Input or PPPPPP [e.g.] The Default Value=, if already changed the Master =, input program mode accessed Exit the program mode Input Master modification Access programming mode 09 PPPPPPRRRRRR [Input the -digit new master code twice.] [e.g.] Set the Master code to be, input 09 DO CARD CODE SITE CODE
3 SOYAL ACCESS CTROL SYSTEM AR-E V0 B. Chang the Node ID of Reader Access programming mode 00 NNN [Node ID: 00~] C.Set up M/M Access programming mode 0 N [N=/] D. Set up the password Card or PIN: Access programming mode UUUUU PPPP [e.g. User address: 0000 and pass code:, input 0000 ] Card and PIN: Access programming mode UUUUU PPPP [e.g. User address: 0000 and pass code:, input 0000 ] E. Anti-pass-back(Reader A and Reader B must to be setting) Usually, anti-pass-back is commonly applied to parking areas in order to prevent from multi-entry with one card at a time, or to situations need access and exit monitor. Controller enable Access programming mode 0 DDD [= Anti-pass-back(0=Disable; =Enable)/ 0=Access/Exit(0=Exit; =Access).] [e.g.] Enable Anti-pass-back, and set to Exit door= ( x ) + (0 x 0) = Access programming mode 0 () Card enable Access programming mode SSSSS EEEEE N [SSSSS= User address start; EEEEE= User address end; N=0(control)/ (Not control)/ (reset)] [e.g.] User address from 00 to 00 enable the anti-pass-back function: [e.g.] No. enable the anti-pass-back, and induction into the door has not been induced to leave. When he re-induction into the door will become invalid, then he needs to set the reset. Access programming mode Reset F. Auto Open Time Zone Door will keep open after the first flashing card.there are time zones supported. Enable/Disable auto open zone Access programming mode 0 00 [00= enable Auto-Open Time Zone; 000= disable Auto-Open Time Zone] Enable/Disable auto open door without presenting card Access programming mode 00 [00= enable Auto-Open Time Zone; 000= disable Auto-Open Time Zone] Set up open time Access programming mode 0 N HHMMhhmm H N: sets of auto-open zone (N=0=st set; N==nd set) HHMMhhmm=Staring time to ending time (e.g. 0000=0:0 to :00) H= days of week (Sat/Fri/Thu/Wed/Tue/Mon/Sun) + Holiday (F= 0: disable; : enable); Holidays establish by the software. [e.g.] To set the second time zone as 9:0 AM to :0 PM, Monday, Wednesday and Friday: Done G. Setting Up the Arming Application: Alarm conditions:. Door open too long: Door is open longer than door relay time plus door close time.. Arming is enabled. Force open (Opened without a valid user card): Access by force or illegal procedure..alarm system connected. Door position abnormal: When power is and then on, reader on arming bffore power. Enable/Disable Arming status (Factory default armingcode is: ) : Standby Mode After door open The normal procedure to open door Input digit arming code Door is not open Input digit arming code Present valid card Enter Program Mode Enable: Access programming mode [The normal procedure to open door] can refer to [Access Mode]. Function Default Value 0 DDD Disable: Access programming mode Attendance 0: Yes : No 0 00 Networking Auto Re-lock : Enable 00 Auto Open : Enable 00 Door open button input 0: Disable : Enable 0 Master Reader of Network 0: Slave : Mater 0 Networking Access/Exit 0: Exit : Access 0 Networking Anti-pass-back : Enable Networking DDD Auto-open door without cards at auto open zone : Enable 0 00 Stop Alarm by door close or by push button 0: None : Yes 0
4 Door WG Controller V0 DDD Can be password-free in the Card or PIN mode Reset the Anti-pass-back by the software Arming for force open : Enable : Enable : Enable 0 0 Selection= 0(none value)/ ( x each value) [e.g.] DDD value of Enable Auto Open + Exit by Push Button + Anti-pass-back =00+0+=; As a result of that, the command will be 0. Mode/ Mode Mode :.Card only;.card and PIN (-digit PIN) + ;.Card or User address (-digit) + Individual PIN (-digit individual PIN) + Mode :.Card only;.card and PIN (-digit individual PIN) + Command List General instructions Function Entering programming mode Exiting programming mode Control mode setting Master card setting Auto-open time zone setting Command PPPPPP 0 N 0 SSSSS EEEEE 0 N HHMMhhmm H ;.Card or PIN (-digit individual PIN) PPPPPP=Master, default value= N=Mode =Mode;=Mode SSSSS-EEEEE= ; SSSSS=Starting user address; EEEEE=Ending user address N= 0(st time zone) / (nd time zone) HHMM= Starting time; hhmm= ending time Notes (i.e.: 0000=0:0 to :00) H= days of week (Sat/Fri/Thu/Wed/Tue/Mon/Sun) + Holiday (F= 0: disable; : enable); Holidays establish by the software. Master code setting 09 PPPPPPRRRRRR PPPPPP=New master code RRRRRR=Repeat the new master code Suspend / Delete tag Active the suspended cards Set the cards as Card mode OR PIN mode 0 SSSSS EEEEE 0 SSSSS 9 EEEEE SSSSS EEEEE UUUUU PPPP =Suspend 9 =Delete; SSSSS=Starting user address, EEEEE=Ending user address SSSSS=Starting card number, EEEEE=Ending card number Access mode: Card or PIN; UUUUU=user address; by user address Set the cards as Card AND PIN mode UUUUU PPPP PPPP=-digit pass code 000~9999 Access mode: Card and PIN; UUUUU=user address; by user address Duress code setting PPPP PPPP=-digit pass code 000~9999 PPPP=-digit pass code (default value=) P.S. Duress code will be unavailable and become a public PIN at access mode Card or PIN of M Card number modification Arming pass code setting UUUUU SSSSSCCCCC PPPP UUUUU= User address; SSSSS=-digit site code; CCCCC=-digit card code PPPP=-digit pass code ( default value=; disable Arming PWD=0000) P.S. Arming PWD code will be unavailable and become a public PIN at access mode Card PIN and of M Door open waiting time Set the card by induction(m/m) TTT 9 UUUUU QQQQQ TTT=Door open waiting time: 00~00=~00 sec.; default value: sec. UUUUU=User address(range: 00000~0999); QQQQQ=Card quantity(0000=continuously inducting) Controller parameter setting Controller time clock setting Anti-pass-back (Enable user) DDD YYMMDDHHmmss SSSSS EEEEE N YYMMDDHHmmss: Year/ Month/ Day/ Hour/ Min./ Sec. SSSSS=Starting user address; EEEEE=Ending user address; N=0/Enable; N=/Disable; N=/Initial Controller control setting Delete all tags DDD 9 9 Individual instruction set Function Keyboard Lock/ Unlock Command Press and hold for seconds to lock the keyboard, again to unlock. Notes Exiting programming mode and enabling arming status Node ID setting (for Reader) Door relay time setting 00 NNN 0 TTT NNN=Node ID, range: 00~ TTT=Door relay time 000= Output constantly 00~00=~00 sec. 0~09=0.~0.9 sec. Alarm relay time setting Controller additional setting 0 TTT 0 DDD TTT=Alarm relay time 00~00=~00 sec.
5 Budapest, Fogarasi út. Tel.: *0-90, 0-, 0-99, 0-, - Fax: 0-90 Mobil: 0 -, Budapest, Mester utca. Tel.: *-, -9, -0, -0, -0 Fax: - Mobil: , info@delton.hu Web:
SOYAL AR-321H/AR-721H/ AR-725H/AR-757H ACCESS CONTROL SYSTEM. Contents AR-321H [Metal Case] AR-721H. AR-725H [Illuminated Touch-panel] AR-725H-M
SOYAL AR-H/AR-H/ AR-H/ ACCESS CONTROL SYSTEM Contents AR-H [Metal Case] Product Water proof Strip d x AR-H Product f x AR-H [Illuminated Touch-panel] AR-H-M Products c x e x A. B. C. D. AR-H Products f
More informationAR-721E-V2 (AR-721E-V2-X) AR-701B-X Fit 35mm DIN Rail or Mount directly 16,000 32,000. Connector CN18 Host TCP/IP. Code Pin Description
SOYAL ACCESS CTROL SYSTEM AR-E-V V0 Contents Product User Guide Panel Mounting Base (AR-E-V-X) Metal Box (AR-E-V-M) Option Option Specification CPU Memory Power Supply Power Consumption Interface / Baud
More informationAR-321 (H) / AR-331 (H)/ AR-721(H) / AR-725 (H) / AR-757 (H)
AR- (H) / AR- (H)/ AR-(H) / AR- (H) / AR- (H) SOYAL ACCESS CONTROL SYSTEM V0 Contents AR- (H):Touch-panel Metal Housing Product User Guide Terminal Cables Tools Water proof Strip d x P P P P AR- (H):Touch-panel
More informationSOYAL AR-321H/AR-331H/ AR-721H/AR-725H/AR-757H ACCESS CONTROL SYSTEM V Contents AR-321H [Touch-panel Metal Housing] 1 Product 2 User Guide 3 Ter
SOYAL AR-H/AR-H/ AR-H/AR-H/AR-H ACCESS CONTROL SYSTEM Contents AR-H [Touch-panel Metal Housing] Product User Guide Terminal Cables Water proof Strip d x AR-H [Touch-panel Metal Housing]/ AR-H-S [Metal
More informationSOYAL AR-725E-M / AR-725E / AR-725X V Contents AR-725E-M. Installation AR-725E-M AR-725E AR-725X. Parts Description AR-725E AR-725X
SOYAL ACCESS CONTROL SYSTEM AR-E-M / AR-E / AR- 0909 Contents AR-E-M Products User Guide Terminal Cables Tools P P P P c x d x A. B. C. D. P P P P AR-E Products User Guide Terminal Cables Tools P P P P
More informationECL-ACC980IP-V2/VP. Contents ECL-ACC980IP-V2. Installation ECL-ACC980IP-V2 ECL-ACC980IP-VP. Parts Description ECL-ACC980IP-VP A. B. C.
EC-ACC90IP-/P Contents EC-ACC90IP- Products User Guide Terminal Cables Tools P P P a x A. E. F. P P P P EC-ACC90IP-P Products User Guide Terminal Cables Tools P P P b x A. B. C. D. P P P P c x Parts Description
More informationSOYAL AR-725 (E-V2) V Contents AR-725 (E-V2-M) Installation AR-725 (E-V2-M) AR-725 (E-V2) AR-725 (X) Parts Description AR-725 (E-V2) AR-725 (X)
SOYAL ACCESS CONTROL SYSTEM AR- (E-V) V0 Contents AR- (E-V-M) Products User Guide Terminal Cables Tools P P P c x d x A. B. C. D. P P P P AR- (E-V) Products User Guide Terminal Cables Tools P P P e x A.
More informationAR-881(EF-MT) P4 P5 P6 P7. P7 only provide to the controller that have doorbell function.
SOYAL ACCESS CONTROL SYSTEM AR- (EF) V00 Contents Product User Guide Terminal Cables Tools Optional P P P Flat Head Cap Philips Tapping Screw: x0 Security Torx: Mx0 WG keyboard AR-(EF-DO) Installation
More informationSOYAL AR-331(EF) Contents. Front Panel & Indicator. Installation. Connector Table CN6 CN2 V Option. 4 Accessories. 2 Terminal Cables 3 Tools
SOYAL ACCESS CONTROL SYSTEM AR- (E/EF) V0 Contents Product Terminal Cables Tools Accessories Option P P Flat Head Cap Philips Tapping Screw: x0 Security Torx: Mx0 AR-(E) AR-(EF) P P P Security Torx Wrenches
More informationBiometrics Device Access controller Fingerprint & Finger Vein V Connector Table () Cable: P Wire Application Anti-Tamper Switch Wire Color Red Orange
SOYAL ACCESS CONTROL SYSTEM AR- (EF-V) / (EV-V) V Contents AR- (EF-V):Fingerprint Products User Guide Terminal Cables Tools Optional P P P AR- (EV-V):Vein P P P AR-RB Products User Guide Terminal Cables
More informationP4 P5 P6. Security trigger signal 2 Purple Security trigger signal Output 6 Thin Blue Wiegand DAT: 1 Input
SOYAL ACCESS CONTROL SYSTEM AR- (E) / (EF) V Contents AR- (EF):Fingerprint Products User Guide Terminal Cables Tools DO AR- (E) Or MT P P P P P P P P P P P P Water proof Strip Optional Products User Guide
More informationPartizan PAB-FC2. Fingerprint scan time Fingerprint identification time. <0.5 s < % <0.0198% Ingress protection rating
1. Features & Technical Parameters 1.1 Features: Partizan PAB-FC2 Metal vandalproof housing Secure and reliable biometric fingerprint recognition Simple for using, wiring can be done by a user without
More informationCV-550SPK V2 Waterproof Keypad/Reader/Controller Installation Instructions
CV-550SPK V2 Waterproof Keypad/Reader/Controller Installation Instructions Packing List NAME MODEL/SIZE QTY Self tapping screw 0.15 x 1.06 (4mm 27 mm) Rubber plug 0.23 x 1.2 (6mm 30 mm) Star screw driver
More informationAR-727H. Technical Manual. 26 August Version 1.00
AR-727H Technical Manual 26 August 2008 Version 1.00 Southern Office: Raytel House Brook Road Rayleigh Essex, SS6 7XH Tel: (01268) 749310 Fax: (01268) 749315 Northern Office: Unit 3 Block 5 Oakbank Industrial
More informationFunction Menu. 1.Add/Delete. 1. Password 2. Access Mode 3. Extend Options 4. Single Floor 5. Multi Floors 6. Enroll FP 7.
Function Menu 1.Add/Delete 2.User Setting 1. Password 2. Access Mode 3. Extend Options 4. Single Floor 5. Multi Floors 6. Enroll FP 7. Delete FP 1. Add - Card ID 2. Add - RF-learn 3. Suspend - Addr 4.
More informationRFID PRODUCT AND SYSTEM
EL500(T)-X-XX Access control system, EM125kHz technology EL500-X-0C EL500-X-1C EL500-X-0D Economic access control system, EM125kHz technology Economic access control system, EM125kHz technology, with keypad
More informationDG-800 Stand-Alone Proximity Reader Instruction Manual
DG-800 Stand-Alone Proximity Reader Instruction Manual I. Features 1. Memory volume up to 1000+10 proximity cards/tokens and PINs with the programming time up to 0.5 seconds. 2. Access modes: a. Only Proximity
More informationSet-up of ZK RFID Pin Pad
Set-up of ZK RFID Pin Pad Version 0. 1 Prepared by: Shaun Laas Softcon Software Control Services (Pty) Ltd. 7 March 2017 Revision History Name Date Reason For Changes Version SL SL 26-Jan- 2016 26-Jan-
More informationPegasus Equipments Export Limited. Local Contact:
Pegasus Equipments Export Limited Add: #31G, Haiyige, Scienway Palace Science & Technology Industrial Park Shenzhen, China. Tel: +86 755 2658 3464 +86 755 2658 3596 Fax: +86 755 8611 0167 web: www.pegasusexport.com
More informationSingle Door Standalone Access Control User Manual
Single Door Standalone Access Control User Manual Reading this manual carefully before install and use the device 1. Packing List Name Quantity Remarks Keypad User manual Screw driver Rubber plug Self
More informationGV-AS Controller. Installation Guide
GV-AS Controller Installation Guide Before attempting to connect or operate this product, please read these instructions carefully and save this manual for future use. 2011 GeoVision, Inc. All rights reserved.
More informationTECHNICAL OPERATION GUIDE
TECHNICAL OPERATION GUIDE CASTLE K-SERIES SYSTEM CASS TECHNOLOGY SDN BHD(338857-X) 1 Disclaimer 2004 Cass Technology Sdn Bhd, All Right Reserved. Information of this documentation is subject to change/modification
More informationACTsmart2 Product Range Operating and Installation Instructions
ACTsmart2 Product Range Operating and Installation Instructions 18-00045 Contents ORDERING INFORMATION......4 INSTALLATION NOTES......5 IMPORTANT......5 PRODUCT SPECIFICATION......5 30 SECOND PROGRAMMING
More informationAR-727HB-RAY AR-716E-RAY EAR-727HB-RAY Series of Controllers
AR-727HB-RAY AR-716E-RAY EAR-727HB-RAY Series of Controllers Installation and Programming Guide AR-716E-RAY EAR-727HB-RAY AR-727HB-RAY 10th August 2011 Version 1.00 Southern Office: Raytel House Brook
More informationSF200. Installation Guide & Quick Start Guide. 2 TFT AC Terminal Version: 1.0 Date: June 2014
SF200 Installation Guide & Quick Start Guide 2 TFT AC Terminal Version: 1.0 Date: June 2014 All design and specification declared are subject to change without notice in advance. Contents Safety Precautions
More informationKP200 INTELLIGENT KEYPAD
KP200 INTELLIGENT KEYPAD V3 NEATROL SYSTEMS 25B Harlond Avenue, Malaga W.A. 6090 Phone : (08) 9248 1646 Fax : (08) 9248 2003 Table of contents 1.1 Summary of Master Functions. 1.2 Explanation of master
More informationVANDAL RESISTANT BACK-LIT WEATHERPROOF ACCESS CONTROL KEYPAD
VANDAL RESISTANT BACK-LIT WEATHERPROOF ACCESS CONTROL KEYPAD Post Mount Keypad Programming & Installation Manual 1. Connect Power 12V DC to 24V AC/DC to terminals (+) and (-) Post Mount Keypad Quick Start
More informationGV-AS200 Controller. Hardware Installation Guide
GV-AS200 Controller Hardware Installation Guide Before attempting to connect or operate this product, please read these instructions carefully and save this manual for future use. 2008 GeoVision, Inc.
More informationThis document mainly introduces the windows and operations of the F18 model 2.4 inch color TFT product.
F18 User Manual Version: 1.0 Date: Dec. 2011 Introduction: This document mainly introduces the windows and operations of the F18 model 2.4 inch color TFT product. About this manual 1. Not all the devices
More informationNetworX Series NX-1710E Single Door Control. Installation and Startup Manual
NetworX Series NX-1710E Single Door Control Installation and Startup Manual 2005 GE Security All rights reserved. NetworX is a trademark of the GE companies. Printed in the USA. These instructions do not
More informationTECHNICAL OPERATION GUIDE
TECHNICAL OPERATION GUIDE CASTLE COMMANDO SERIES CONTROLLER Disclaimer 2004 Cass Technology Sdn Bhd, All Right Reserved. Information of this documentation is subject to change/modification without any
More informationStandalone Keypad Access Control. User Manual. Please read the manual carefully before use this unit
Standalone Keypad Access Control User Manual Please read the manual carefully before use this unit 1. Packing List Name Quantity Remarks Keypad 1 User manual 1 Screw driver 1 Φ20mm 60mm,Special for keypad
More informationStandalone Keypad Access Control. User Manual. SS-TS2000 Size:120*80*25 mm
Standalone Keypad Access Control User Manual SS-TS2000 Size:120*80*25 mm Please read the manual carefully before use this unit 1. Packing List Name Quantity Remarks Keypad 1 User manual 1 Screw driver
More informationCM-110SK Standalone Keypad Installation Instructions
CM-0SK Standalone Keypad Installation Instructions. Packing List Qty Name Remarks 2 2 Keypad User manual Screwdriver Wall plugs Self-tapping screws Torx screw 0.8 x 2.4 Φ(20 mm 60 mm) 0.24 x.2 Φ (6 mm
More informationBioPointe Reader Installation Guide
BioPointe Reader Installation Guide What s in this Guide Installation Steps 1 Key Parts of the BioPointe Reader 2 Cabling Requirements 3 Power Connection 3 PXL-500W Wiegand Controller Connection 3 Serial
More informationFingerprint Access Control F1. User Manual
Fingerprint Access Control F1 User Manual 1. Introduction F1 is a metal shell standalone fingerprint access control, using the America Atmel s MCU, with precise electron circuit and good productive technology.
More informationFTK5 PROXIMITY KEYPAD
FTK5 PROXIMITY KEYPAD Before using the unit, please read the instructions and retain for future reference 1 There are 600 user codes (fobs or cards) and 1 programming code: Careful administration records
More informationInstallation and User Manual
S2 Metal Waterproof Access Control Unit Installation and User Manual (Ness Part No. 101-082) 1 Introduction Ness S2 is an advanced, waterproof (IP65 rated) proximity and PIN Access Controller. S2 can support
More informationACTpro Single Door IP Controller. Operating & Installation Instructions
ACTpro 1500 Single Door IP Controller Operating & Installation Instructions 18-00079 Issue 1 This manual refers to the ACTpro 1500 a TCP/IP based control unit supporting up to 32 doors. Access Control
More informationSecurity at Fingertips
Security at Fingertips www.esslsecurity.com Contents 1. Operating Instruction... - 1-1.1 Abbreviated Operating Procedures... - 1-1.2 Introduction to Fingerprint Recognition technology... - 2-1.3 About
More informationU-FLASH Setup Guide U-FLASH.
U-FLASH Setup Guide Thank you for purchasing the U-FLASH. This guide will assist you in the setup of the system. You can call for FREE technical support to get help anytime at 757-258-0910. Please note,
More informationTwo Door Controller GEN-045
Australian Owned, Designed and Manufactured Two Door Controller GEN-045 Genesis Electronics Australia Pty Ltd www.genesiselectronics.com.au Distributed by: Genesis reserves the right to change or modify
More informationAS Keypad User Manual
AS Keypad User Manual Specifications Operating Voltage: 12~24 VAC/DC Current Draw: TBA Input: request-to-exit (for Relay 1) time out reed switch contact (for Relay 1) Output: Relay 1: N.O./N.C./Com. Output
More informationEZTAG3 PROXIMITY AND KEYPAD DOOR ENTRY
EZTAG PROXIMITY AND KEYPAD DOOR ENTRY USER MANUAL www.espuk.com EZTAG Manual_Layout.indd 8//06 5:8:0 System Components Proximity and Reader 0 x Proximity Tags x Hex Key x Plastic wall plug x Countersunk
More informationVisit us on the World-Wide Web at Programming Guide. Controller Boards
Visit us on the World-Wide Web at www.chamberlain.com PRO Systems Programming Guide Controller Boards -106 & -107 PROKey PROCard TABLE OF CONTENTS INTRODUCTION About the PRO System................................3
More informationEZ-TAG2 Manual_Layout 5 11/12/ :14 Page 1 U S E R M A N UAL
EZ-TAG2 Manual_Layout 5 11/12/2012 09:14 Page 1 USER MANUAL EZ-TAG2 Manual_Layout 5 11/12/2012 09:14 Page 2 Contents EZ-TAG2 and Back Plate 1 x Security Torx Key 4 x Screws and raw plugs 1 x Marking out
More informationACCESS CONTROL QUICK INSTALL GUIDE. tel: +44 (0) fax: +44 (0) web:
ACCESS CONTROL QUICK INSTALL GUIDE tel: +44 (0)1457 874 999 fax: +44 (0)1457 829 201 email: sales@cop-eu.com web: www.cop-eu.com WIRING CONFIGURATION - ACS CONTROLLERS CONNECTIONS Dahua access controllers
More informationBewator Granta Controller Installation Handbook
Bewator Granta 4101-2 Controller Installation Handbook Copyright 2004 Bewator AB, Solna. This handbook is based on the best information available to Bewator Cotag at the time of publication. Although every
More informationQUICK START GUIDE. 2.4 Inch Finger Vein Terminal Time Attendance & Access Control
QUICK START GUIDE 2.4 Inch Finger Vein Terminal Time Attendance & Access Control Version: 1.0 Date: Apr., 2017 1 2.4-Inch TFT LCD USB Storage Device Port Keypad& Card Reader Doorbell & LED Indicator Fingerprint
More informationISC GB-XX ISC GB-XX ISC GB-XX ISC GB-XX
ISC910-1-0-GB-XX ISC911-5-0-GB-XX ISC920-0-0-GB-XX ISC921-5-0-GB-XX The ImproX IXP20 is a fully featured, stand-alone Access Control System supporting up to 1 000 Tagholders and 5 000 transactions. Designed
More informationDigital Keypad Introduction
K2 Digital Keypad Introduction The K02 uses the latest microprocessor technology to operate door strikes and security systems that require a momentary (timed) or latching dry contact closure. All programming
More informationAXS-100. User's Guide. Two-Door Proximity Access Control System (V2.06) DE6280U 1
AXS-100 Two-Door Proximity Access Control System (V2.06) User's Guide Table of Contents 1. INTRODUCTION... 3 2. USER INTERFACE... 3 2.1. Keypad...3 2.2. Idle Screen...3 2.3. Login Screen...4 2.4. Operating
More informationMULTI-PURPOSE SELF-CONTAINED DIGITAL ACCESS CONTROL KEYPAD
MULTI-PURPOSE SELF-CONTAINED DIGITAL ACCESS CONTROL PAD Programming & Installation Manual An Innovative Product Developed By: PROTECT - ON SYSTEMS LTD. MANUFACTURED BY: 20 R SINCE 1979 ADVANCED ELECTRONICS
More informationIPassan Installation guide
IPassan Installation guide 1 Content 1 Overview... 3 1.1 Features... 3 1.2 Hardware... 3 1.2.1 s... 3 1.2.2 Extra modules... 5 1.3 IPassan manager... 7 2 Installation... 7 2.1... 8 2.1.1 Power supply...
More information2.4 inch Color Screen Series User Manual
2.4 inch Color Screen Series User Manual Version: 1.3 Date: June 15, 2013 Introduction: This document mainly introduces interface and operation of 2.4 Inches color products. ALARM INTERNATIONAL SYSTEMS
More information2 Zone Time Clock. User Guide UFHTIME2B
2 Zone Time Clock User Guide UFHTIME2B Overview The 2 Zone Time Clock is designed to work with the Dial Thermostat (UFHDIALB) to provide time control per manifold. Time clock also has 1 other zone which
More informationgenesis TECHNICAL MANUAL Two-Door Controller GEN-045
Two-Door Controller GEN-045 Genesis Electronics Australia Pty Ltd www.genesiselectronics.com.au info@genesiselectronics.com.au Australian Owned, Designed and Manufactured Distributed By:- Genesis reserves
More informationEZTAG3 PROXIMITY AND KEYPAD DOOR ENTRY
EZTAG Manual.qxp_Layout 0/0/06 :7 Page EZTAG PROXIMITY AND KEYPAD DOOR ENTRY USER MANUAL www.espuk.com EZTAG Manual.qxp_Layout 0/0/06 :7 Page System Components Proximity and Reader 0 x Proximity Tags x
More informationStartup Guide. NetAXS-123. Version 5.2
NetAXS-123 Startup Guide Version 5.2 This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2)
More informationUser Manual. Split access control with intelligent secured power supply.
User Manual Split access control with intelligent secured power supply. Contents. Introduction, features and specifications. Installation and Wiring Diagram 3. Manager Card Operation 4. User Settings 5.
More informationInstallation Instructions (KF-2000)
VERSION 2005. 10 Installation Instructions (KF-2000) Keico Hightech, Inc. Installation Instructions KF-2000 Keico Hightech Ace Twin Tower I 12 th FL 212-1, Guro-Dong, Guro-Gu Phone +82-2-853-9000 Fax +82-2-830-7809
More informationCV-110SPK Standalone Keypad/Prox Access Control Installation Instructions
CV-110SPK Standalone Keypad/Prox Access Control Installation Instructions 1. Packing List Qty Name Remarks 1 1 1 2 2 1 Keypad User manual Screwdriver Wall plugs Self-tapping screws Torx screw 0.8 x 2.4
More information2000 Series e/em Style Keypad Installation and Programming Manual
2000 Series e/em Style Keypad Installation and Programming Manual Document Number: 6054022 Revision: 0 Date: 12/21/06 Table of Contents Table of Contents Section 1: Introduction... 6 1 Product Description...6
More informationKey Switch. Document version: 1.5 (Updated 02 May 2017)
Key Switch Document version: 1.5 (Updated 02 May 2017) Contents ii Contents 1 Key Switch R10S.3... 4 2 Quick Guides...4 2.1 Controlling an Electric Lock...5 2.2 Controlling an Alarm System... 5 2.3 Controlling
More informationPRO3200 Professional Modular Access Control Hardware
PRO3200 Access Control Hardware As a part of the WIN-PAK software controlled hardware family the PRO3200 professional modular access control hardware is an advanced access control panel capable of providing
More informationQuick Start Installation Guide
apc/l Quick Start Installation Guide Version A2 Document Part Number UM-201 May 2010 OVERVIEW The apc/l is an intelligent access control and alarm monitoring control panel which serves as a basic building
More informationF6-Fingerprint. Access Control/Reader. User Manual. F6 - Simplified Instruction. (Master Code) # (Factory default:1234) Enter the Programming Mode
-Fingerprint Access Control/Reader Function Description Enter the Programming Mode - Simplified Instruction Operation (Factory default:1234) Change the Master Code Add Fingerprint User Add Card User Add
More informationACCESS CONTROL SOFTWARE V3.1 REFERENCE MANUAL
ACCESS CONTROL SOFTWARE V3.1 REFERENCE MANUAL 01/2004 Centaur is a registered trademark of Position Technology INC. Pro-Report, Tracker, FrontGuard and FrontView are trademarks of Position Technology Inc.
More informationW3-H Waterproof Keypad/Reader/Controller
W3-H Waterproof Keypad/Reader/Controller User Manual 1. Packing list Name Quantity Digital Keypad W3-H 1 User Manual 1 Screw Driver Rubber Bungs Self Tapping Screws Diode 1 4 4 1 Manager Card 2 Remark
More informationCreated by: Alarm System Store Quick Start Guide. for Interlogix NetworX NX4, NX6 & NX8
Quick Start Guide for Interlogix NetworX NX4, NX6 & NX8 Programming Code = 9713 Master User Code=1234 Program Mode= *8 + 9713 To exit programming hit the Exit key until you reach the home screen If this
More informationWiring Guide EP.NMINI. Version 1.02 Last Updated:
Wiring Guide EP.NMINI Version 1.02 Last Updated: 14-10-2014 1 Note: See http://www.entrypass.net/ for updates, revisions, and download the latest installation manual There are currently 2 version of EntryPass
More informationGV-AS/EV Controller. User s Manual
GV-AS/EV Controller User s Manual Before attempting to connect or operate this product, please read these instructions carefully and save this manual for future use. AS100.110.120.210.400.410.810-EV48-C
More informationUSER MANUAL. BioPro SA50 Fingerprint & Palm Terminal. Version: 1.0 Date: August Inch TFT Terminal User Manual 1
USER MANUAL BioPro SA50 Fingerprint & Palm Terminal Version: 1.0 Date: August. 2017 2.4 Inch TFT Terminal User Manual 1 About This Manual This manual introduces the operation of user interfaces and menu
More informationON-LINE PROXIMTY ACCESS CONTROLLER OPERATION MANUAL MODEL: HA3035 VERSION: 2.9x
ON-LINE PROXIMTY ACCESS CONTROLLER OPERATION MANUAL MODEL: HA05 VERSION: 2.9x HEART ENTERPRISE CO. LTD. HEART ENTERPRISE CO., LTD. 0 Chapter I Introduction. Introduction 5.2 Features 5. Specification 6.
More informationINSTALLATION INSTRUCTIONS 921P EntryCheck TM
80 Avenida Acaso, Camarillo, Ca. 90 (805) 494-06 www.sdcsecurity.com E-mail: service@sdcsecurity.com INSTALLATION INSTRUCTIONS 9P EntryCheck TM The EntryCheck 9P Indoor/Outdoor Keypad is a surface mount
More information_ Access control SISTEMAS DE SEGURIDAD
_ Access control SISTEMAS DE SEGURIDAD SECURITY SYSTEMS Access control 01 Concept 02 Product 03 Characteristics 04 Compatibility 05 New functions 06 New software 07 References, accessories and diagrams
More informationTwo-door Access Controller
Two-door Access Controller Quick Start Guide V1.0.0 Preface Overview This document elaborates on structure, installation, interface and wiring of two-door access controller. Symbol Definition The following
More informationKP2000E/EM Series Style Keypad
23852973 KP2000E/EM Series Style Keypad Installation and Programming Instructions Models KP2000EXX and KP2000EMXX Specifications Parameter Voltage Requirements Keypad Current Requirements (Max) Relay Contact
More informationGSM HOME SECURITY SYSTEM
Cell /Mobile phone home security system GSM HOME SECURITY SYSTEM Model : BS120 TABLE OF CONTENTS 1. FEATURES... 1 2. APPLICATION... 2 3. SPECIFICATIONS... 3 4. FRONT PANEL & LAYOUT DESCRIPTION...6 5. BASIC
More informationQUICK START GUIDE. 2.4 Inch TFT Terminal Time Attendance & Access Control
QUICK START GUIDE 2.4 Inch TFT Terminal Time Attendance & Access Control Safety Precautions The following precautions are to keep user safe and prevent any damage. Please read carefully before installation.
More informationSynergis Master Controller 2.2 Integration Guide for Axis Interface Modules
Synergis Master Controller 2.2 Integration Guide for Axis Interface Modules This guide supplements the Synergis Master Controller Configuration Guide and explains how to configure Axis interface modules
More informationNetworX Series. NX-507E RELAY EXPANDER NX-508E OUTPUT EXPANDER Installation and Startup
NetworX Series NX-0E RELAY EXPANDER NX-0E OUTPUT EXPANDER Installation and Startup NX-0E / NX-0E AUXILIARY MODULES TABLE OF CONTENTS I. GENERAL DESCRIPTION... II. WIRING INFORMATION... III. NX-0E TERMINAL
More informationInstallation & User Manual
Contents Installation Instructions 3 Installation Diagrams 4 System Overview 6 Wiring Diagrams 8 Network Diagrams 9 Operation Instructions Fingerprint Enrollment 12 21 Wi-Enterprise Controller www.transmittersolutionssmart.com
More informationDINB100-SA-KIT Standalone Biometric Kit
DINB100-SA DINRTT DINB100-SA-KIT Standalone Biometric Kit User Manual v.b3 Contents 1.0 INTRODUCTION... 3 2.0 MOUNTING AND DISMOUNTING... 3 3.0 SPECIFICATIONS... 3 4.0 APPLICATION DIAGRAM... 4 5.0 WIRING...
More informationSL2000E. Status Output. Electronic Code Lock. Features. Input. Exit Button Input. Introduction. Door Contact Input. Functional Description.
SL2000E Electronic Code Lock Features Door Relay output Status transistor output Aux transistor output Door Contact input Exit Button input INSTALLER code for programming MASTER code for arming/disarming
More informationK44 Code lock. Technical manual
K44 Code lock GB Technical manual Copyright 2002 Bewator AB, Solna, Sweden. Material from the K44 Technical manual may only be copied with the consent in writing of Bewator. Bewator reserves the right
More informationBHD-8000 Access Control Keypad and Card Reader. Wiring Diagram
BHD-8000 Access Control Keypad and Card Reader Wiring Diagram Frontal View Main Technical Specifications Item Operating Voltage Unlock Relay Operating Temperature Value 12VDC+12%/1.2A 12VDC/2A Normal Operation:
More informationWiring Guide. EP.NMiNi 2. Version 1.04 Last Updated:
Wiring Guide EP.NMiNi 2 Version 1.04 Last Updated: 31-01-2013 Before you begin Technical Support If you cannot find the answer to your question in this manual or in the Help files, we recommend you contact
More informationNetworX Series. NX-507E RELAY EXPANDER NX-508E OUTPUT EXPANDER Installation and Startup
NetworX Series NX-0E RELAY EXPANDER NX-0E OUTPUT EXPANDER Installation and Startup NX-0E / NX-0E AUXILIARY MODULES TABLE OF CONTENTS I. GENERAL DESCRIPTION... II. WIRING INFORMATION... III. NX-0E TERMINAL
More informationWebpass IP Reader. WEB Configuration Manual
Webpass IP Reader WEB Configuration Manual WEBPASS version : v0.09 Aug-24 th -2009 (HW.1.0) WEBPASS Web version : v1.4 Build date : Aug-18 th -2009 Revision History 1. Newly added Event Type : Alarm and
More informationTAC I/NETTM 1284, 1280, Security Control Unit
TAC I/NETTM The SCU () family of modular, stand-alone controllers are basic building blocks of the I/NET Seven Security Management System, and provide a flexible mix of door control and alarm monitoring
More informationEntryphone. PinNet 4. Product manual. October 2010 R Granville Road, London SW18 5SD
Entryphone PinNet 4 Product manual October 2010 R4.9 www.entryphone.co.uk 23 Granville Road, London SW18 5SD This document covers the installation and use of the Entryphone on-line PinNet door control
More informationFirst Access Express OPERATOR GUIDE
First Access Express OPERATOR GUIDE October 2016 Cutting edge simplicity Table of Contents Introduction... 4 PC Requirements... 5 Step 1. Software Installation... 5 Complete Installation Server and Client...
More informationC5S120 Installation and Connection Guide
C5S120 Installation and Connection Guide Version: V1.1 1. Cautions Please note the following cautions. Mis-operation may lead to personal injury or equipment failure: 1) Do not energize the system before
More informationIQ PROX. Programming Guide. Series. For use with IQ KP* only
IQ PROX Series Programming Guide For use with IQ KP* only Congratulations, you have just purchased the IQ KP*series lockset by Marks USA, the most advanced stand-alone door lock and access control system
More informationA-1300 Biometric Access Control System USER'S MANUAL
A-1300 Biometric Access Control System USER'S MANUAL Table of Contents 1. General Information... 1 1.0 Notification... 2 1.1 System Overview... 2 1.2 Main Features... 2 1.3 Equipment... 3 2. Basic Concepts...
More information6222 Two Door Module Technical Operations Manual
6222 Two Door Module Technical Operations Manual TABLE OF CONTENTS Specifications...3 Overview...4 Operations...5 Custom Access Mode...5 Standard Access Mode...5 Offline Access Mode...5 Offline Memory...5
More informationUser s Manual V
User s Manual V2. 28.1.21 Table of Contents 1 About BF-88X/87X...3 2 Features...3 2.1 Characteristics...3 2.2 Support functions...3 2.2.1 User management...3 2.2.2 System management...4 2.2.3 Door mode...4
More informationSmartLock Pro INSTALLATION MANUAL
SmartLock Pro INSTALLATI MANUAL July 2010 Cutting edge simplicity Table of Contents INTRODUCTI... 3 Diodes... 3 Power Supply Notice... 3 Terminal Strips and Cable... 4 SPECIFICATIS... 5 SMARTLOCK CTROLLER
More informationGV-AS/EV Controller. User s Manual
GV-AS/EV Controller User s Manual Before attempting to connect or operate this product, please read these instructions carefully and save this manual for future use. ASEV-H 2016 GeoVision, Inc. All rights
More information