DT-RLC. User Manual. Lock/Light Control Interface

Size: px
Start display at page:

Download "DT-RLC. User Manual. Lock/Light Control Interface"

Transcription

1 Lock/Light Control Interface User Manual WIRE SYSTEM V S INUSE Please read this manual carefully before using the product you purchase, and keep it well for future use.we reserve the right to modify the specification in this manual at any time without notice.

2 .About Interface Description: The relay actuator is an accessory device designed for DT system to control door locks and/or light. It has following features: Two work modes: lock control mode and light control mode; Allows to open gate door locks or control lights; Support high powerconsumption lock; Configurable unlock timed output or light control timed output; Support : when in lock control mode, the exit button operating the lock; when in light control mode, the exit button operating the light. Parts V S WIRE SYSTEM Lock Control Jumper V S INUSE INUSE V: V power output. Can be used to power PowerontoOpen Electic lock max holding current 450mA S: Reserved : Exit button contact. Short and to unlock or control light : The common Ground of the other contacts:, S and V

3 :The normallyclosed contact to : The common contact of the unlock/light relay : The normallyopen contact to Lock Control Jumper: To select the lock type: see section 5., 5.4 :Working indicator, it will light up when powered IN USE:Unlock/light indicator, lights up when unlock or turn on the light Bus:Connect to the bus line, no polarity :Used for setting the address of the RLC. Unit Mounting WIRE SYSTEM V S INUSE DIN Rail Mounting 4. How To Set The Work Mode Factory default is Lock Control Mode ).Set =, =, = OFF, Short and and will go into the setting mode; ).Struck repeatedly 4x times to switch work modes: A. INUSE indicator flashes once means Interface in the light control mode B. INUSE indicator flashes two times means Interface in the lock control mode ).When the setting complete it will restart automatically Please note the setting state valid within 5 seconds. If more than 5 seconds without any action taken setting mode exits automatically

4 5. Lock Control Mode In lock control mode, the allows to open gate door locks; Support high powerconsumption lock; With configurable unlock timed output; Support 5. How to set the unlock time In lock control mode: ). Poweron and within 5 seconds, shortcircuit and S until INUSE indicator flashes ). Shortcircuit and until INUSE indicator lights up ). Shortcircuit and S and start counting flashes. INUSE indicator flashes once per second. The maximum unlocking time is 0 seconds 4). When desired time reached, remove shortcircuit. Time will be saved automatically 5. switches settings for lock The switches at the back are used to set the address of the RLC. Please refer to the following tables: State Descriptions OFF,OFF,OFF Applies to door station & lock OFF,OFF, Applies to door station & lock,off,off Applies to door station & lock,off, Applies to door station & lock OFF,,OFF Applies to door station & lock

5 INUSE V S WIRE SYSTEM V S State Descriptions OFF,, Applies to door station & lock,,off Applies to door station 4 & lock,, Applies to door station 4 & lock 5. Lock powered by RLC (only for PowerontoOpen lock) maximum holding current is 450mA controls the second lock (Electric) of door station Electriclock AC~ # Camera (Address:0) monitor PC6 (IM) (DS) L L PL S S 4

6 INUSE V S WIRE SYSTEM V S Closeup Connection Note:. When Electric lock connected, the jumper position in. When Emagnetic lock connected, the jumper position in Electriclock * V S Jumper position in 5.4 Lock Powered with extra Power supply A. PowerontoOpen: controls the second lock (Electric) of door station adaptor for the lock Elock AC~ # Camera (Address:0) monitor PC6 (IM) (DS) L L PL S S 5

7 INUSE V S WIRE SYSTEM V S Closeup Connection. Electric Lock Elock SUPPLY * V S Jumper position in B.PowerofftoOpen: controls the second lock (magnetic) of door station adaptor for the lock EMlock AC~ # Camera (Address:0) monitor PC6 (IM) (DS) L L PL S S 6

8 Closeup Connection. Magnetic Lock SUPPLY EMLOCK * V S Jumper position in 6. Light Control Mode In light control mode, the allows to control lights with configurable time output; Support 6. How to set the light working time In light control mode: ). Poweron and within 5 seconds, shortcircuit and S until INUSE indicator flashes ). Shortcircuit and until INUSE indicator lights up ). Shortcircuit and S and start counting flashes. INUSE indicator flashes once per second= equals 0 sec of light On. The maximum time light can stay On is 900 sec 4). When desired time reached, remove shortcircuit. Time will be saved automatically 6. switches settings for light Bit State Descriptions OFF,OFF,OFF Set for the first 7

9 INUSE V S WIRE SYSTEM V S Bit State Descriptions OFF,OFF, Set for the second,off,off Set for the third,off, Set for the fourth OFF,,OFF Set for the fifth OFF,, Set for the sixth,,off Set for the seventh,, Set for the eighth 6. Connection for Light Control 0~50V AC Input AC~ (Address:0) monitor PC6 (IM) (DS) L L PL S S 8

10 INUSE INUSE V S V S RF CARD 7. Connecting s In one system, you can connect a to control gate door lock, and connect another to control light adaptor for the lock Elock Safety Type: poweron to open poweroff to lock 0~50V AC Input AC~ N N L SW LED PC6 (IM) (DS) monitor (Address:0) 9

11 8. Specifications Power Supply : DC4V Unlocking Time: ~0s (Default s) Lock Power supply: Vdc, 450mA (Internal Power) Working Temperature: 0 0 C~40 0 C Dimension: H89 W7 D45mm The design and specifications can be changed without notice to the user. Right to interpret and copyright of this manual are preserved. DTENGRLCV 05096

DT-RLC. User Manual. Relay actuator

DT-RLC. User Manual. Relay actuator Relay actuator User Manual WIRE SYSTEM COM NC V S S INUSE RISER Please read this manual carefully before using the product you purchase, and keep it well for future use.we reserve the right to modify the

More information

8. Electric Lock Connection

8. Electric Lock Connection 6. Switches Settings Total 6 bits in the switches can be configured. The switches can be modified either before or after installation. 1 3 5 6 (1) OFF (0) = = Bit1,Bit and Bit 3 are used for door station

More information

DK KIT. Quick Guide

DK KIT. Quick Guide 2 WIRE INTERCOM SYSTEM DK1711-22 KIT Quick Guide RF CARD RF CARD Please read this manual carefully before using the product you purchase, and keep it well for future use.we reserve the right to modify

More information

DT-SCU. User Manual. Camera Interface

DT-SCU. User Manual. Camera Interface DT-SCU Camera Interface User Manual 2-Wire System Model: SCU Camera Interface Power In-Use CAM1 CAM2 CAM(1~4) CAM3 CAM4 Please read this manual carefully before using the product you purchase, and keep

More information

USER MANUAL EVD2-10OU. 2-Wire. Video Intercom System. Read this manual carefully before using the product, and keep it well for future use.

USER MANUAL EVD2-10OU. 2-Wire. Video Intercom System. Read this manual carefully before using the product, and keep it well for future use. USER MANUAL EVD2-10OU 2-Wire Video Intercom System Read this manual carefully before using the product, and keep it well for future use. Parts and Function The door station is an audio door station without

More information

Wiring Inside the card reader you will see a circuit board. The connections are as follows:

Wiring Inside the card reader you will see a circuit board. The connections are as follows: Power Adaptor (12VDC, Max. Current: 1A) If you purchased the Cardlock Series power supply cut the head of the adaptor and strip the insulation. If your locking mechanism, electric strike or magnetic lock

More information

DPA-D2-QSW a video quad splitter

DPA-D2-QSW a video quad splitter DPA-D2-QSW a video quad splitter User manual .About QSW Unit Discription: The QSW module is designed to 2D system for the purpose of video quad splitter, four images from 4 different cameras can be displayed

More information

2 -Wire Intercom System

2 -Wire Intercom System 2 -Wire Intercom System DT591/592 User Manual DT591 DT592 DT-ENG-591/592-V1 160603 CTENTS 1.Parts and Functions... 1 2.Terminal Descriptions... 1 3.Specifications... 2 4.Mounting... 2 4.1 Mounting Without

More information

2 -Wire Intercom System

2 -Wire Intercom System 2 -Wire Intercom System DT591/592 User Manual DT591 DT592 DT-ENG-591/592-V1 100S719 CTENTS 1.Parts and Functions... 1 2.Terminal Descriptions... 1 3.Specifications... 2 4.Mounting... 2 4.1 Mounting Without

More information

2-Wire Video Intercom System

2-Wire Video Intercom System DT597 USER MANUAL(EN) 2-Wire Video Intercom System Read this manual carefully before using the product, and keep it well for future use. Introduction The door station is designed with high resolution

More information

2-Wire Video Intercom System

2-Wire Video Intercom System DT594 USER MANUAL(EN) 2-Wire Video Intercom System Read this manual carefully before using the product, and keep it well for future use. Introduction The door station is designed with high resolution color

More information

DT-TPS. User Manual. Telephone Interface 2-wire series.

DT-TPS. User Manual. Telephone Interface 2-wire series. DT-TPS Telephone Interface 2-wire series User Manual www.intelligenthomeonline.com 1 About TPS Telephone Interface The TPS Telephone Interface is designed for 2-wire series video door entry systems. Enables

More information

2 WIRE INTERCOM SYSTEM

2 WIRE INTERCOM SYSTEM ENGLISH 2 WIRE INTERCOM SYSTEM USER MANUAL Please read this manual carefully before using the product, and keep it well. DT-ENG-17/TD7-V1 Contents 1.Parts and Functions... 1 2.Monitor Mounting... 2 3.Main

More information

2-Wire Video Intercom System

2-Wire Video Intercom System 2-Wire Video Intercom System DPC-D246A User s manual 4P terminal Parts and Function The door station is an audio door station without camera, which is designed for 2-wire system. The front panel is made

More information

2 -Wire Intercom System

2 -Wire Intercom System 2 -Wire Intercom System FTDEV1P User Manual FTDEV1P_Instructions _Rev02 CTENTS 1.Parts and Functions... 1 2.Terminal Descriptions... 1 3.Specifications... 2 4.Mounting... 2 4.1 Mounting Without Rainy Cover...

More information

RFID/Digital Access Control Keypad

RFID/Digital Access Control Keypad R Luminous/ RFID/Digital Access Control Keypad Model:YK-368L-R Germany EMC tested FEATURES AND FUNCTIONS Simple Programming, Easy Operation 3-Operation Mode: ID Card Operation, User Code Operation, ID

More information

DT-AKP 2 WIRE SYSTEM. User Manual. Access keypad panel with scramble keypad DT-ENG-AKP-V1 /

DT-AKP 2 WIRE SYSTEM. User Manual. Access keypad panel with scramble keypad DT-ENG-AKP-V1 / DT-ENG-AKP-V1 / 201701 2 WIRE SYSTEM DT-AKP Access keypad panel with scramble keypad User Manual RF CARD Please read this manual carefully to ensure safe and correct operation. Keep this manual well for

More information

2-Wire Video Outdoor Station

2-Wire Video Outdoor Station English 2-Wire Video Outdoor Station User Manual RF CARD DT601FE/ID DT-ENG-601FE/ID-V1 151019 Contents 1.Parts and Functions... 1 2.Terminal Descriptions... 1 3.Door Station Mounting... 2 4. System Wiring

More information

MODEL KP-100 ACCESS CONTROL DIGITAL KEYPAD OPERATING INSTRUCTIONS

MODEL KP-100 ACCESS CONTROL DIGITAL KEYPAD OPERATING INSTRUCTIONS MODEL KP-100 ACCESS CONTROL DIGITAL KEYPAD OPERATING INSTRUCTIONS Model KP-100 is a self-contained digital keypad. This keypad is suitable for residential, industrial, and commercial installations. It

More information

Digital Keypad Introduction

Digital Keypad  Introduction K2 Digital Keypad Introduction The K02 uses the latest microprocessor technology to operate door strikes and security systems that require a momentary (timed) or latching dry contact closure. All programming

More information

2-Wire Video Outdoor Station

2-Wire Video Outdoor Station English 2-Wire Video Outdoor Station User Manual RF CARD RF CARD DT601/ID DT601F/ID DT-ENG-601(F)ID-V1 140526 Contents 1.Parts and Functions... 1 2.Terminal Descriptions... 1 3.Door Station Mounting...

More information

DPC-D245 2-wire door station

DPC-D245 2-wire door station DPC-D245 2-wire door station. User manual O N 1 2 1 2 178 Introduction The door station is designed with high resolution color CCD camera, it provides wide angle of 105 0 for 2-wire intercom system. The

More information

62G from 1.0 from surface. K&J D x.50, N42. 69G from 1.75 from surface. 236G from 1.25 from surface.

62G from 1.0 from surface. K&J D x.50, N42. 69G from 1.75 from surface. 236G from 1.25 from surface. FX50 Datasheet Electrical Specifications Input voltage 6 26V Outputs 1 Solid State Relay, 40V (max), 2A Hall Sensor Linear Hall Sensor, AH8500 Processor NXP/Freescale ARM Cortex M0+ Magnetic Specifications

More information

Front view. Internal view. Legend

Front view. Internal view. Legend SWING audio handset 7 Description WIRE audio handset for wall mounted installation. It s fitted with keys for: door lock release, and programmable keys (---), which operating mode is set through the configuration.

More information

AUDIO AND VIDEO DOOR ENTRY SYSTEM WITH NEXA CODED PANEL

AUDIO AND VIDEO DOOR ENTRY SYSTEM WITH NEXA CODED PANEL AUDIO AND VIDEO DOOR ENTRY SYSTEM WITH NEXA CODED PANEL 2 INTRODUCTION First and foremost we would like to thank you for purchasing this product. Our commitment to satisfying our customers can be seen

More information

Compact Coded Magnetic Safety Interlock Switch and Control Units

Compact Coded Magnetic Safety Interlock Switch and Control Units C Conforms to EN292, EN60204-1, EN954-1, EN1088, EN60947-5-3, EN947-5-3, EN50081, EN50082, EN61000-6-2 UL and C-UL listed, TUV certified Description R US Compact Coded Magnetic Safety Interlock Switch

More information

Phone: Fax: Web: -

Phone: Fax: Web:  - In automated systems, sensors and actuators must interact with one another functionally and safely. The necessary coordination is performed by the programmable Safety Controller. The controller monitors

More information

2 WIRE video door entry system

2 WIRE video door entry system CLASSE 00 AM Audio handset with additional keys WIRE video door entry system 7 Description WIRE audio handset for wall mounted or table-top installation (with specific support to be purchased separately).

More information

2 -Wire Intercom System

2 -Wire Intercom System 2 -Wire Intercom System DT596(F)/ID User Manual RF CARD RF CARD DT596/ID DT596F/ID DT-ENG-596(F)ID-V1 110S923 Contents 1.Parts and Functions... 1 2.Terminal Descriptions... 1 3.Door Station Mounting...

More information

Magnetic Style Safety Interlock Switches

Magnetic Style Safety Interlock Switches Non-contact safety interlock switches are the best choice for washdown applications; the switch components are sealed and rated NEMA 4X, IEC IP67 Tolerant of dirt buildup, sensing distance, and alignment

More information

Alecto Video Door System

Alecto Video Door System Alecto Video Door System 2-wire Series Installation and User Manual Digital Touch Screen 7 inch Monitor www.intelligenthomeonline.com -1- PRECAUTIONS Read this manual through before using the product.

More information

AUDIO AND VIDEO KITS SECTION CONTENTS 66

AUDIO AND VIDEO KITS SECTION CONTENTS 66 66 SECTION CONTENTS 68 General features Catalogue 70 Audio kits 74 Video colour kits 76 Video black and white kits 77 Video black and white kits with memory COMMUNICATION GENERAL CATALOGUE 07/08 67 Audio

More information

DT-TPS. User Manual. telephone interface

DT-TPS. User Manual. telephone interface DT-TPS telephone interface User Manual Please read this manual carefully before using the product you purchase, and keep it well for future use.we reserve the right to modify the specification in this

More information

GSM HOME SECURITY SYSTEM

GSM HOME SECURITY SYSTEM Cell /Mobile phone home security system GSM HOME SECURITY SYSTEM Model : BS120 TABLE OF CONTENTS 1. FEATURES... 1 2. APPLICATION... 2 3. SPECIFICATIONS... 3 4. FRONT PANEL & LAYOUT DESCRIPTION...6 5. BASIC

More information

DT243-D4 4.3" COLOR TFT MONITOR USER MANUAL. Please read this manual carefully before using the product you purchase,and keep it well for future use.

DT243-D4 4.3 COLOR TFT MONITOR USER MANUAL. Please read this manual carefully before using the product you purchase,and keep it well for future use. 2 DT-ENG-243-D4-V1 / 201612 2 WIRE SYSTEM DT243-D4 4.3" COLOR TFT MITOR USER MANUAL Please read this manual carefully before using the product you purchase,and keep it well for future use. Please note

More information

PM4 INSTRUCTIONS. PM4 WIRING (See Tables 1 & 2 and Wiring Examples)

PM4 INSTRUCTIONS. PM4 WIRING (See Tables 1 & 2 and Wiring Examples) INSTRUCTIONS The can control 4 independent power sub-districts that can each be set up as either a "Short Circuit Manager" (default) or an "Auto-Reversing Controller." A separate booster can power each

More information

1/6 SINGLE-FAMILY KIT WITH QUADRA AND MAXI. SB SYSTEM AWARDS KIT VIDEO QUADRA DOOR ENTRY SYSTEMS OVERVIEW HFX-9000M

1/6 SINGLE-FAMILY KIT WITH QUADRA AND MAXI. SB SYSTEM AWARDS KIT VIDEO QUADRA DOOR ENTRY SYSTEMS OVERVIEW HFX-9000M 1/6 OVERVIEW The HFX9000M brings innovative technology and modern elegance to your home or business. The system is convenient and easy to use providing your home or office the perfect solution for video

More information

DT607 Series 2 WIRE SYSTEM USER MANUAL. Fisheye door station with proximity access control DT-ENG-DT607-V1 /

DT607 Series 2 WIRE SYSTEM USER MANUAL. Fisheye door station with proximity access control DT-ENG-DT607-V1 / DT-ENG-DT607-V1 / 201607 2 WIRE SYSTEM DT607 Series Fisheye door station with proximity access control USER MANUAL DT607/ID/FE-S1 DT607/ID/FE-S2 DT607A/ID-S4 DT607/ID/FE-S3 DT607/ID/FE-S4 DT607F/ID/FE-S4

More information

4 Wire Video Intercom System

4 Wire Video Intercom System VT596(F)/KP USER MANUAL(EN) 4 Wire Video Intercom System VT596/KP VT596F/KP Read this manual carefully before using the product, and keep it well for future use. -1-1. Parts and Functions Camera Lens Speaker

More information

Instruction Manual. Vogue. Security. Technology. Innovation 2013-V01

Instruction Manual. Vogue. Security. Technology. Innovation 2013-V01 Instruction Manual DH16A-60DTE Model 60 with plastic keypad, stand alone access control DH16A-60DTQE Model 60 with plastic keypad, networked access control 2013-V01 Security Technology Vogue Innovation

More information

NUOVO TOUCH INTERCOM SYSTEM

NUOVO TOUCH INTERCOM SYSTEM NUOVO TOUCH INTERCOM SYSTEM USER MANUAL Please read this manual carefully before using the product. L1 L2 ON DIP 1 2 3 4 5 6 1. Overview Digital TFT LCD Screen SD card Talk/MON Button Menu Button Unlock

More information

Advantages of a Full Featured 700 Series Relay

Advantages of a Full Featured 700 Series Relay SECTION 1 Advantages of a Full Featured 700 Series Relay Since the launch of the 700 series relays in 2000, this product line has continuously evolved both functionally and visually. The 700 series product

More information

Video Door Entry System

Video Door Entry System Video Door Entry System user manual This manual covers DT6913SD and DT6913 Monitor www.intelligenthomeonline.com PRECAUTIONS Read this manual through before using the product. Slots or openings in the

More information

The DVT Ethernet IO Module (CON-IOE)

The DVT Ethernet IO Module (CON-IOE) The DVT Ethernet IO Module (CON-IOE) Revision 4 (11/11/04) DVT Corporation DVT Corporation Installation of DVT Ethernet IO Module (CON-IOE) Hardware Mechanical Installation: The CON-IOE is designed to

More information

PQ V ac. CONTROL PANEL 230V FOR ROLLING SHUTTERS Instructions Manual. Control panel for electric rolling shutters 230Vac TECHNICAL FEATURES

PQ V ac. CONTROL PANEL 230V FOR ROLLING SHUTTERS Instructions Manual. Control panel for electric rolling shutters 230Vac TECHNICAL FEATURES CONTROL PANEL 230V FOR ROLLING SHUTTERS Instructions Manual Q45 230V ac Control panel for electric rolling shutters 230Vac Built-in radio receiver 433Mhz Adjustable pause time for automatic closing function

More information

DG-800 Stand-Alone Proximity Reader Instruction Manual

DG-800 Stand-Alone Proximity Reader Instruction Manual DG-800 Stand-Alone Proximity Reader Instruction Manual I. Features 1. Memory volume up to 1000+10 proximity cards/tokens and PINs with the programming time up to 0.5 seconds. 2. Access modes: a. Only Proximity

More information

TAC I/NETTM 1284, 1280, Security Control Unit

TAC I/NETTM 1284, 1280, Security Control Unit TAC I/NETTM The SCU () family of modular, stand-alone controllers are basic building blocks of the I/NET Seven Security Management System, and provide a flexible mix of door control and alarm monitoring

More information

WELCOME. For customer support or any inquiries, please visit our web site at or contact us at

WELCOME. For customer support or any inquiries, please visit our web site at  or contact us at WELCOME Congratulations on purchasing the GBF Smart Four Wire Intercom System. Our factory engineers were the first to enable multiple security cameras being monitored through a smart mobile device and

More information

Tel Fax: Toll free:

Tel Fax: Toll free: ELECTRONIC CONTROL UNIT (cod. 2302B Series) for swing gates automation (Mini Tank Series) C5 Accessories power supply: 24V dc Max 200 ma T1 Trimmer regulation: Operating times Open pause time Leaf delay

More information

K44 Code lock. Technical manual

K44 Code lock. Technical manual K44 Code lock GB Technical manual Copyright 2002 Bewator AB, Solna, Sweden. Material from the K44 Technical manual may only be copied with the consent in writing of Bewator. Bewator reserves the right

More information

405A Timer with Instantaneous Relay

405A Timer with Instantaneous Relay < Marsh Bellofram Group of Companies < Automatic Timing & Controls < Timer < 405A Series Downloadable Files: 405A Series 405A Timer with Instantaneous Relay On-Delay version with instantaneous relay Selectable

More information

Touch control HD4657M3 HD4657M4 HC4657M3 HC4657M4 HS4657M3 HS4657M4

Touch control HD4657M3 HD4657M4 HC4657M3 HC4657M4 HS4657M3 HS4657M4 Description The touch control is a device in which conventional buttons are replaced by capacitive sensors. The device can then carry out some typical functions of a SCS control when you simply touch its

More information

CM Series. Most Diverse and Flexible Line of Coded Magnetic Safety Interlock Switches and Controllers. Description. Safety Interlock Switches

CM Series. Most Diverse and Flexible Line of Coded Magnetic Safety Interlock Switches and Controllers. Description. Safety Interlock Switches R Safety Interlock Switches CM Series CM For full product information, visit www.sti.com. Use the SpeedSPEC Code for quick access to the specific web page. Most Diverse and Flexible Line of Coded Magnetic

More information

2-Wire Video Intercom System

2-Wire Video Intercom System DT43/D4 USER MANUAL(EN) 2-Wire Video Intercom System Read this manual carefully before using the product, and keep it well for future use. NC GND RING sw- sw+ L1 L2 3 ON DIP NC GND RING sw- sw+ L1 L2 3

More information

MiG2 CONTROLLERS. 2 & 4 Stage General Purpose Controllers, with Air-conditioning Facilities

MiG2 CONTROLLERS. 2 & 4 Stage General Purpose Controllers, with Air-conditioning Facilities MiG2 CONTROLLERS 2 & 4 Stage General Purpose Controllers, with Air-conditioning Facilities The MiG2 controllers incorporate: 2 Inputs (Configurable as Resistive, 0 10V, 0 20mA or 4 20mA) 2 or 4 Relay Outputs

More information

smartentry Wireless Video Doorphone User Manual

smartentry Wireless Video Doorphone User Manual smartentry Wireless Video Doorphone User Manual Designed & Engineered Version 1.2 in the United Kingdom Contents Precautions... 3 1. Product Overview... 4 1.1. Product Features... 4 1.2. Contents... 4

More information

EZ-TAG2 Manual_Layout 5 11/12/ :14 Page 1 U S E R M A N UAL

EZ-TAG2 Manual_Layout 5 11/12/ :14 Page 1 U S E R M A N UAL EZ-TAG2 Manual_Layout 5 11/12/2012 09:14 Page 1 USER MANUAL EZ-TAG2 Manual_Layout 5 11/12/2012 09:14 Page 2 Contents EZ-TAG2 and Back Plate 1 x Security Torx Key 4 x Screws and raw plugs 1 x Marking out

More information

U-FLASH Setup Guide U-FLASH.

U-FLASH Setup Guide U-FLASH. U-FLASH Setup Guide Thank you for purchasing the U-FLASH. This guide will assist you in the setup of the system. You can call for FREE technical support to get help anytime at 757-258-0910. Please note,

More information

MULTI-PURPOSE SELF-CONTAINED DIGITAL ACCESS CONTROL KEYPAD

MULTI-PURPOSE SELF-CONTAINED DIGITAL ACCESS CONTROL KEYPAD MULTI-PURPOSE SELF-CONTAINED DIGITAL ACCESS CONTROL PAD Programming & Installation Manual An Innovative Product Developed By: PROTECT - ON SYSTEMS LTD. MANUFACTURED BY: 20 R SINCE 1979 ADVANCED ELECTRONICS

More information

Installation Manual BAK02

Installation Manual BAK02 Installation Manual BAK02 XXXXXXXX/10-02-2014 Attention. Before installing the equipment, carefully read the SAFETY WARNINGS contained in the package as they provide important instructions regarding the

More information

CYPRESS " " EXP SPX Expansion interface! modules EXP-2000_MAN_0314

CYPRESS   EXP SPX Expansion interface! modules EXP-2000_MAN_0314 CYPRESS EXP-2000 SPX Expansion interface! modules The EXP-2000 provides additional Door/Panel interface points to most SPX products. The EXP-2000 uses a local RS-485 network through an SPX gateway device.

More information

Operating Instructions KEYPAD. Compatible WIRELESS ACCESS CONTROL

Operating Instructions KEYPAD. Compatible WIRELESS ACCESS CONTROL Operating Instructions KEYPAD Compatible WIRELESS ACCESS CONTROL Contents Technical specifications page 1 Approvals page 1 Changing the Master code page 2 Adding a User code page 3 Deleting a User code

More information

INSTALLATION INSTRUCTIONS 921P EntryCheck TM

INSTALLATION INSTRUCTIONS 921P EntryCheck TM 80 Avenida Acaso, Camarillo, Ca. 90 (805) 494-06 www.sdcsecurity.com E-mail: service@sdcsecurity.com INSTALLATION INSTRUCTIONS 9P EntryCheck TM The EntryCheck 9P Indoor/Outdoor Keypad is a surface mount

More information

AS Keypad User Manual

AS Keypad User Manual AS Keypad User Manual Specifications Operating Voltage: 12~24 VAC/DC Current Draw: TBA Input: request-to-exit (for Relay 1) time out reed switch contact (for Relay 1) Output: Relay 1: N.O./N.C./Com. Output

More information

Operating Instructions DIGITAL COUNTER VEK CN1. Version 2002_03

Operating Instructions DIGITAL COUNTER VEK CN1. Version 2002_03 Operating Instructions DIGITAL COUNTER VEK CN1 Version 2002_03 1/1 NOTE: COPYRIGHT 2001 Magnetic Automation Corp. All rights reserved. No part of this publication may be reproduced, transmitted, transcribed,

More information

EcoEntry. RFID Proximity Access Control System. User Guide. Revision 2

EcoEntry. RFID Proximity Access Control System. User Guide. Revision 2 EcoEntry RFID Proximity Access Control System User Guide Revision 2 Introduction The ecoentry door access system allows the user to open the door using a keyfob, password, or keyfob plus password. Specification

More information

Quick Start Guide. SEB-710 I/O Expansion board. Introduction

Quick Start Guide. SEB-710 I/O Expansion board. Introduction SEB-710 I/O Expansion board Revision 1.0 - (March, 2011) Saflec Systems (Pty) Ltd Quick Start Guide Introduction The SEB-710 is an I/O expansion device for additional inputs and outputs. It has eight relay

More information

DIGITAL PANEL THERMOMETER

DIGITAL PANEL THERMOMETER Love Controls DIGITAL PANEL THERMOMETER LCI108-2x LCI108J-2x INSTRUCTIONS MANUAL EDITION: February 2001 INTRODUCTION TO THE LOVE CONTROLS LCI108 SERIES This manual does not constitute a formal agreement.

More information

The SMART Non-contact Safety Sensor SRF With an innovative diagnostic system

The SMART Non-contact Safety Sensor SRF With an innovative diagnostic system The SMART With an innovative diagnostic system Actual size shown Very compact: small in size, flexible in use Very Smart: suitable for Industry 4.0 with its intelligent diagnostic system Cost Saving: four-wire

More information

Flush Mount SIP Access Control Intercom Installer s Guide

Flush Mount SIP Access Control Intercom Installer s Guide Flush Mount SIP Access Control Intercom Installer s Guide This step-by-step guide will help you install your Wahsega Labs flush mount SIP access control intercom. What s in the Box A. (1) VoIP intercom

More information

EPGG001. Fieldbus Gateway RS-232 to PROFINET. Industrial Communication. Technical Data. Part Number

EPGG001. Fieldbus Gateway RS-232 to PROFINET. Industrial Communication. Technical Data. Part Number Fieldbus Gateway RS-232 to PROFINET EPGG001 Part Number Easy handling Gateway from RS-232/422/485 interfaces to PROFINET With two Industrial Ethernet ports Technical Data Electrical Data Supply Voltage

More information

PUSH BUTTON PANEL. SECTION 3A (Rev. B) SECTION CONTENTS. Download from Technical Manuals area. sec.3a

PUSH BUTTON PANEL. SECTION 3A (Rev. B) SECTION CONTENTS. Download from  Technical Manuals area. sec.3a SECTION 3A (Rev. B) Download from www.urmet.com Technical Manuals area. SINTHESI 2 CAMERA MODULE AND DOOR UNIT WITH 2 BUTTONS...2 Features...2 Structure...2 Terminals pins description...3 Technical characteristics...3

More information

MyHOME. automation. DIN contacts interface F428

MyHOME. automation. DIN contacts interface F428 DIN contacts interface MyHOME Description This devices let you integrate traditional control devices (switches, pushbuttons, etc.) in advanced systems with BUS operating logic. Therefore, it is possible

More information

MSI Safety Devices PRODUCT INFORMATION

MSI Safety Devices PRODUCT INFORMATION MSI Safety Devices PRODUCT INFORMATION A top system from the relay to the controller. MSI safety devices from Leuze electronic. With the MSI safety relays and safety controllers, optoelectronic safety

More information

2-WIRE INTERCOM SYSTEM

2-WIRE INTERCOM SYSTEM 2-WIRE INTERCOM SYSTEM User Instruction Public video memory module Staircase light controller Extra cameras extended DT-ENG-SC6V Versions1.0 Introduction The SC6V module is designed for DT system for public

More information

PSR-SCP- 24DC/SDC4/2X1/B PSR-SPP- 24DC/SDC4/2X1/B

PSR-SCP- 24DC/SDC4/2X1/B PSR-SPP- 24DC/SDC4/2X1/B PSR-SCP- 24DC/SDC4/2X1/B PSR-SPP- 24DC/SDC4/2X1/B Safety Relay for Emergency Stop and Safety Door Circuits INTERFACE Data Sheet 102858_02_en PHOENIX CONTACT - 12/2006 Description The PSR-...- 24DC/SDC4/2X1/B

More information

MCX402DR-BRD I/O expander. Operating Manual

MCX402DR-BRD I/O expander. Operating Manual Roger Access Control System MCX402DR-BRD I/O expander Operating Manual Product version: 1.0 Firmware version: 1.0.2.255 Document version: Rev. B Design and application The MCX402DR-BRD is I/O expander

More information

WEBS-ZPS Zone Paging System Instructions

WEBS-ZPS Zone Paging System Instructions I. Introduction Model WEBS-ZPS Zone Paging System is a modular telephone zone paging and control system for use with analog WEBS stations (such as WEBS-MT/R, WEBS-WM and WEBS-PA-2A). It is expandable up

More information

IPassan Installation guide

IPassan Installation guide IPassan Installation guide 1 Content 1 Overview... 3 1.1 Features... 3 1.2 Hardware... 3 1.2.1 s... 3 1.2.2 Extra modules... 5 1.3 IPassan manager... 7 2 Installation... 7 2.1... 8 2.1.1 Power supply...

More information

Installation manual CF8-W-Disp-AL

Installation manual CF8-W-Disp-AL Installation manual CF8-W-Disp-AL CO 2 transmitter with two relays mounted in industrial housing prepared for Modbus communication protocol 4 7 8 8 6 3 2 5 Wall plate 5 Snap-in lid 2 PCB (Factory supplied

More information

RS485 MODBUS Module 6RO

RS485 MODBUS Module 6RO Version 2.0 12/02/2013 Manufactured for Thank you for choosing our product. This manual will help you with proper support and proper operation of the device. The information contained in this manual have

More information

2-Wire Video Outdoor Station

2-Wire Video Outdoor Station English 2-Wire Video Outdoor Station User Manual 4 5 6 7 8 9 0 # 4 5 6 7 8 9 0 # DT601/KP DT601F/KP DT-ENG-601(F)KP-V1 141122 Contents 1.Parts and Functions... 1 2.Terminal Descriptions... 1 3.Door Station

More information

EA-R03 Wireless Keypad Controller Kit Operating Instructions

EA-R03 Wireless Keypad Controller Kit Operating Instructions Package Contents Normal Use EA-R02-202 Receiver EA-R03-103 Wireless Keypad Transmitter Keypad Mounting Packet Power/Auxiliary Connector Wire Harness Lock/Unlock Relay Connector Wire Harness User Instructions

More information

PAC1 Door Access Controller

PAC1 Door Access Controller PAC1 Door Access Controller Series 1 TABLE OF CONTENTS i PAGE Introduction...1 Features...1 Specifications...2 Terminal Descriptions...3 Programmable Features Description...5 Automatic Relock Function...5

More information

Click Save to return to the main Setup screen.

Click Save to return to the main Setup screen. ON-SITE Setup Guide Thank you for purchasing the ON-SITE. This guide will assist you in the setup of the system. You can call for FREE technical support to get help anytime at 757-258-0910. Please note,

More information

A P K I T K P C O L O U R V I D E O D O O R E N T R Y S Y S T E M U S E R M A N U A L. w w w. e s p u k. c o m

A P K I T K P C O L O U R V I D E O D O O R E N T R Y S Y S T E M U S E R M A N U A L. w w w. e s p u k. c o m APKITKP Manual.qxp_Layout 1 28/01/2016 11:45 Page 1 A P K I T K P C O L O U R V I D E O D O O R E N T R Y S Y S T E M U S E R M A N U A L w w w. e s p u k. c o m APKITKP Manual.qxp_Layout 1 28/01/2016

More information

RIO-2010BM Use RIO-2010BM to connect Watson IoT platform and work with Node-RED User Guide

RIO-2010BM Use RIO-2010BM to connect Watson IoT platform and work with Node-RED User Guide RIO-2010BM Use RIO-2010BM to connect Watson IoT platform and work with Node-RED User Guide Version: 1.2 2018 May Trademarks The Artila logo is a registered trademark of Artila Inc. All other trademarks

More information

PAC1 Door Access Controller

PAC1 Door Access Controller PAC1 Door Access Controller Series 1 100% Designed and Manufactured by: NIDAC SECURITY PTY. LTD. 2 CROMWELL STREET BURWOOD, VICTORIA Tel: (03) 9808 6244 AUSTRALIA 3125 Fax: (03) 9808 9335 Revision 1.1

More information

I / O Expander. Instrument for torque control ASL 11/17

I / O Expander. Instrument for torque control ASL 11/17 Instrument for torque control I / O Expander ASL 11/17 3000920 ENGLISH Pictograms WARNING It can be dangerous to use this machine if the operating instructions are not carefully followed. Before using

More information

Full Height Turnstile Manual

Full Height Turnstile Manual Full Height Turnstile Manual 1 Dear respected customers: Preface Thank you for purchasing our Full Height Turnstile. The Full Height Turnstile are available with standard electrical interface and compatible

More information

05/16-01 PC Monobloc Audio Digital Entrance Panel. Installer manual

05/16-01 PC Monobloc Audio Digital Entrance Panel. Installer manual 05/16-01 PC 343100 Monobloc Audio Digital Entrance Panel Installer manual 2 Contents Monobloc Audio Digital Entrance Panel 1 Introduction 4 1.1 Warnings and recommendations 4 2 Description 5 2.1 Main functions

More information

Safety Switching Devices SNO 4003K. Basic device for Emergency-Stop and Safety Gate Applications PI E

Safety Switching Devices SNO 4003K. Basic device for Emergency-Stop and Safety Gate Applications PI E EN 60204-1 Stop category 0 EN 954-1 Safety category 4 Basic device to EN 60204-1 and EN 954-1 single E-stop monitoring. Manual or automatic start Application up to safety category 2 and stop category 0

More information

I-7520: RS-232 to RS-485. Input: RS-232 protocol Output:RS-485/RS-422 Speed: Self Tuner 'inside, auto switching baud rate, 300~ BPS

I-7520: RS-232 to RS-485. Input: RS-232 protocol Output:RS-485/RS-422 Speed: Self Tuner 'inside, auto switching baud rate, 300~ BPS I-7520 RS-232 to RS-485 Converter I-7510 RS-485 Repeater RS-232 RS-485 I-7000 SERIES Common Specifications Isolation voltage: 3000VDC Speed: 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115000 Dual watchdog

More information

9212i INSTALLATION. Stand-Alone Keypad. Instructions

9212i INSTALLATION. Stand-Alone Keypad. Instructions INSTALLATION 9212i Stand-Alone Keypad Instructions Features: 4 Independent Outputs 4 Independent Timers All Outputs Assignable by Code On board 5 Amp Form C Relay 120 Users Remote Triggering Input Keypad

More information

Installation Manual & User Instructions. MultiCom 100 / 500

Installation Manual & User Instructions. MultiCom 100 / 500 Installation Manual & User Instructions For MultiCom 100 / 500 Multi apartment GSM Intercom System 1 P a g e M u l t i c o m 1 0 0 i n s t a l l i n s t r u c t i o n s v 1 Contents Section Description

More information

Each receiver has 4 switched outputs, which, using our one touch easy-learn process can be controlled from any switch on any compatible transmitter.

Each receiver has 4 switched outputs, which, using our one touch easy-learn process can be controlled from any switch on any compatible transmitter. SABRE Series RUGGED REMOTE CONTROL SYSTEM Features 4 switch relays - 1200W each Up to 4000m Range 12-32Vac/dc and 230Vac supply Completely waterproof ABS enclosure (IP68) All outputs momentary, latching

More information

VANDAL RESISTANT BACK-LIT WEATHERPROOF ACCESS CONTROL KEYPAD

VANDAL RESISTANT BACK-LIT WEATHERPROOF ACCESS CONTROL KEYPAD VANDAL RESISTANT BACK-LIT WEATHERPROOF ACCESS CONTROL KEYPAD Post Mount Keypad Programming & Installation Manual 1. Connect Power 12V DC to 24V AC/DC to terminals (+) and (-) Post Mount Keypad Quick Start

More information

Network Video Recorder Quick Operation Guide

Network Video Recorder Quick Operation Guide Network Video Recorder Quick Operation Guide UD.6L0202B1351A01 TABLE OF CONTENTS NVR Pre-Installation... 2 NVR Installation... 2 Hard Disk Installation... 2 Front Panels... 6 DS-9500NI-ST/RT Front Panel...

More information

SDM-8AO. Expansion Module 8 analog outputs. Manufactured for

SDM-8AO. Expansion Module 8 analog outputs. Manufactured for Version 1.0 16.05.2014 Manufactured for Thank you for choosing our product. This manual will help you with proper support and proper operation of the device. The information contained in this manual have

More information

Manual and application description KNX/EIB LED driver V2.0

Manual and application description KNX/EIB LED driver V2.0 1 Manual and application description KNX/EIB LED driver V2.0 2 1. Device description 1.1 General KNX/EIB LED allows dimming one RGB LED strip as well as 3 standard LED lamps. There are also three binary

More information