AMERICAN FITTINGS. Corporation. SPEC-grade. EMT Connectors Compression Type. EMT CONDUIT EMT Connectors: Compression Type Size Range: 1/2 to 4
|
|
- Juniper Young
- 5 years ago
- Views:
Transcription
1 EMT Connectors: Compression Type EMT Connectors Compression Type For connecting and bonding electric metallic tubing to a box or enclosure Concrete Tight 1/2 to 4 Screw Machined Steel, zinc plated * EMT Connectors Compression (EC) EMT Conduit Fittings 1 EC750US 1/ EC751US 3/ EC752US EC753US 1-1/ EC754US 1-1/ EC755US EC756US 2-1/ EC757US EC758US 3-1/ EC759US /2 & Larger May Be Steel or Malleable Iron Cat. # Diameter Length Length of Thread EC750BUS EC751BUS EC752BUS EC753BUS EC754BUS EC755BUS EC756BUS EC757BUS EC758BUS EC759BUS EC750BUS 1/ EC751BUS 3/ EC752BUS EC753BUS 1-1/ EC754BUS 1-1/ EC755BUS EC756BUS 2-1/ EC757BUS EC758BUS 3-1/ EC759BUS Copyright 2013, Fair Page 49
2 EMT Connectors: Compression Type / Raintight EMT Connectors Compression Type/Raintight RAIN AND CONCRETE TIGHT 1/2 to 4 For use in wet locations to ground and secure EMT raceway boxes and enclosures Connector utilizes internal and external sealing rings to prevent entrance of water or moisture Screw machined steel, zinc plated * EMT Conduit Fittings 2 EMT ConnectorCompression - Raintight (EC RT) EC750USRT 1/ EC751USRT 3/ EC752USRT EC753USRT 1-1/ EC754USRT 1-1/ EC755USRT EC756USRT 2 1/ EC757USRT EC758USRT 3 1/ EC759USRT Cat. # Diameter Length Length of Thread EC750USRT EC751USRT EC752USRT EC753USRT EC754USRT EC755USRT EC750BUSRT 1/ EC751BUSRT 3/ EC752BUSRT EC753BUSRT 1-1/ EC754BUSRT 1-1/ EC755BUSRT EC756BUSRT 2 1/ EC757BUSRT EC758BUSRT 3 1/ EC759BUSRT Copyright 2013, Fair Page 50
3 EMT Couplings: Compression Type EMT Couplings Compression Type For coupling two ends of electric metallic tubing Concrete Tight 1/2 to 4 Screw Machined Steel, zinc plated * EMT Conduit Fittings 3 EMT Couplings Compression (EC) EC760US 1/ EC761US 3/ EC762US EC763US 1-1/ EC764US 1-1/ EC765US EC766US 2-1/ EC767US EC768US 3-1/ EC769US A B Cat. # Length Diameter EC760US EC761US EC762US EC763US EC764US EC765US EC766US EC767US EC768US EC769US
4 EMT Couplings: Compression Type / Raintight EMT Couplings Compression Type/Raintight RAIN AND CONCRETE TIGHT 1/2 to 4 For use in wet locations to ground and secure EMT raceway boxes and enclosures Connector utilizes internal and external sealing rings to prevent entrance of water or moisture Screw machined steel, zinc plated * EMT Couplings Compression - Raintight (EC RT) EMT Conduit Fittings 2 EC750USRT 1/ EC751USRT 3/ EC752USRT EC753USRT 1-1/ EC754USRT 1-1/ EC755USRT EC756USRT 2 1/ EC757USRT EC758USRT 3 1/ EC759USRT Cat. # Diameter Length Length of Thread EC750USRT EC751USRT EC752USRT EC753USRT EC754USRT EC755USRT EC750BUSRT 1/ EC751BUSRT 3/ EC752BUSRT EC753BUSRT 1-1/ EC754BUSRT 1-1/ EC755BUSRT EC756BUSRT 2 1/ EC757BUSRT EC758BUSRT 3 1/ EC759BUSRT Copyright 2013, Fair Page 50
5 EMT Connectors / Set Screw Type EMT Connectors Set Screw Type For connecting & bonding electrical metallic tubing to a box or enclosure Steel, zinc plated * UL rated concrete tight when taped ø EMT Connectors - Set Screw (SS) SS50US 1/ SS51US 3/ SS52US SS53US 1-1/ SS54US 1-1/ SS55US SS56US 2-1/ SS57US SS58US 3-1/ SS59US EMT Conduit Fittings 5 Cat. # Overall Length Diameter Length of Thread SS50/BUS SS51/BUS SS52/BUS SS53/BUS SS54/BUS SS55/BUS SS56/BUS SS57/BUS SS58/BUS SS59/BUS SS50BUS 1/ SS51BUS 3/ SS52BUS SS53BUS 1-1/ SS54BUS 1-1/ SS55BUS SS56BUS 2-1/ SS57BUS SS58BUS 3-1/ SS59BUS
6 EMT Couplings / Set Screw Type EMT Couplings Set Screw Type For coupling two ends of electrical metallic tubing Steel, zinc plated * UL rated Concrete Tight when Taped ø EMT Couplings - Set Screw (SS) EMT Conduit Fittings 6 SS60US 1/ SS61US 3/ SS62US SS63US 1-1/ SS64US 1-1/ SS65US SS66US 2-1/ SS67US SS68US 3-1/ SS69US A B Cat. # Length Diameter SS60US SS61US SS62US SS63US SS64US SS65US SS66US SS67US SS68US SS69US Copyright 2013, Fair Page 54
Arlington Industries, Inc.
rlington Industries, Inc. 800/233-4717 FX 570/562-0646 Insulating ushings Press fit. Holds firmly in place while pulling cables. TLOG UP/DI/NED TRDE UNIT STD DIM DIM NUMER MFG #01 8997 SIZE PKG PKG 50
More informationCATALOG FITTINGS CATALOG
CATALOG FITTINGS CATALOG Since 1994 AFC Fittings has been providing quality connectors, fittings, and couplings for wiring applications employing AC & MC cables, EMT, Flexible Metal Conduits and Liquidtight
More information1 5 / 8" 7 /8" 2" 7 /8" 75. 3" 7 /8" 75 Polyurethane HI-TECH Delrin / /16 3/4
For use on wood furniture that can accept a 3 /8" diameter hole approximately 1 5 /8" deep. No.20 pressed steel adapter (Part #50011) with toothed base is supplied. size: 5 /16" diameter x 1 1 /2" long.
More informationArlington Industries, Inc.
Intersystem ridges vailable in zinc or bronze. Provides reliable intersystem bonding between power and communication grounding systems. Comes with textured, paintable, white cover. Cover is UV rated plastic
More informationRigid Fittings. Insulated Ground Bushings c/w Aluminum Lay-In Lug. Bushings. Diecast. Malleable Iron. Available in Hot Dipped Galvanized
Insulated Ground Bushings c/w Aluminum Lay-In Lug Diecast Ground Lug Capacity 20BIZ4L 14-4 1/2" 100 21BIZ4L 14-4 3/4" 50 22BIZ4L 14-4 1" 25 23BIZ4L 14-4 1-1/4" 25 24BIZ4L 14-4 1-1/2" 25 25BIZ4L 14-4 2"
More informationONE GANG WEATHERPROOF OUTLET BOXES - DIE CAST METAL BWF Product Benefits & Features B-5V DB-5V B5-2V. Applications
For over 50 years, BWF/M. Stephens has been a leader in the die casting industry. With the full line of outdoor weatherproof products, BWF/M. Stephens is committed to offering the high quality and customer
More informationPEREGRINE SERIES RETROFIT INSTALLATION GUIDE
06.05.17 HanleyLED H100W-PPS524V Spec Sheet SOLUTIONS THAT MAKE SENSE PEREGRINE SERIES RETROFIT INSTALLATION GUIDE Light Up New Markets Your Local Distributor: Grimco US www.grimco.com 800.542.9941 Canada
More informationSolar Combiner Enclosure
Installation Instructions Solar Combiner Enclosure Catalog Numbers 1000-SB006, 1000-SB012 Topic Page Description 1 Important Safety Instructions 3 Nameplate Data 4 Planning for Installation 4 Install the
More informationUltima X5000 Round Duct Mount Kit User Instructions
Ultima X5000 Round Duct Mount Kit User Instructions MSA Kit 10179124/10179321 - Ultima X5000 316 Stainless Steel Parts List / Instructions Round Duct Mount Gasket (1) Round Duct Mount Base Plate (1) Base
More informationSee the. Difference. SolutionS in a snap TIME SAVER. Youtube Channel. Scan to visit our. For the
See the Difference TIME SAVER For the SolutionS in a snap Scan to visit our Youtube Channel committed to installing in a snap www.bptfittings.com more snap-in solutions The Bri BriDgeporT DgeporT Difference:
More informationDS185 1G FS Box Switch Cover. Features. Description. Manufacturer Information EATON CROUSE-HINDS SERIES GTIN
3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 DS185 1G FS Box Switch Cover Cooper Crouse-Hinds Catalog Number Manufacturer Description Weight per unit Product Category
More informationCompression fittings Metric and inch
Fittings Compression fittings Metric and inch Ø 4 to 28 mm tube Ø 3 /16" to È" tube Wide range of types and sizes. Rugged and durable. Suitable for use under extreme conditions of temperature and pressure.
More informationENCLOSURES AND JUNCTION BOXES: NEC/CEC EXPLOSIONPROOF OUTLET BOXES. Applications
GR and GRF Conduit Outlet Boxes Applications Complies with a wide range of classified area requirements. Corrosion-resistant: ideal indoors or out. For pulling of wires. Connect conduit lengths and change
More informationNE15-LIST. NET Price List Schedule Effective Date: 04/01/14
NET Price Schedule Effective Date: 04/01/14 Replaces: NE14 Roughing-in Products EMT, Rigid, Aluminum Conduit & Fittings Grounding Accessories Conduit Bodies Explosion-Proof Fittings Signaling & Switches
More informationFILTER NAME CONSTRUCTION FEATURES APPLICATIONS ORDER CODE MEMBRANE Body: polycarbonate Filter: PTFE membrane
Filter Caps for Humidity and Dewpoint Transmitters with probe 12 mm (0.47 ) The right choice of appropriate filter cap is essential for best long term performance in the application. For assistance please
More informationCool Drawer Single Sensor
The Cool Drawer Single Sensors allow crystal installation into the sensor from the side, convenient for systems with insufficient room for front load crystal installation. The Cool Drawer Single Sensor
More informationPlease Read Instruction Carefully Before Installation! Figure 1: A/CO2-DUCT
Installation and Operation Instructions A/CO2-DUCT Series Please Read Instruction Carefully Before Installation! Figure 1: A/CO2-DUCT PRECAUTIONS REMOVE POWER BEFORE WIRING. NEVER CONNECT OR DISCONNECT
More informationNominal. Mounting. Length foot foot RUN Nominal Lengths* Suspension Bracket 1 Studs (Factory installed) Rotating Crossbar
M125 Project: Type: Qty: Series Lamping Mounting Nominal Length Finish Voltage Options Series M125R1 Flanged M125R2 Flanged / Flush Endcaps M125 For Concrete Pour Only Lamping 1T5 2T5 1T8 2T8 1T5HO 2T5HO
More informationMeter Enclosure and Equipment Standards
Meter Enclosure and Equipment Standards (a) (b) General Requirements: CITY OF OCALA UTILITY SERVICES METER ENCLOSURE AND EQUIPMENT STANDARDS: (1) To avoid the costs associated with having to replace unacceptable
More informationConnectivity Products
Cable Glands Strain Relief Snap-In Labels Lock Nuts Torque Wrench Protective Sleeves U2 U5 U5 U6 U7 U8 Features NPT and PG thread cable glands in nylon or metal materials Locknuts in multiple thread sizes
More informationNE16-LIST. List Price List Schedule Effective Date: 03/01/15
Price Schedule Effective Date: 03/01/15 Replaces: NE15 Roughing-in Products EMT, Rigid, Aluminum Conduit & Fittings Grounding Accessories Conduit Bodies Explosion-Proof Fittings Signaling & Switches Weatherproof
More informationTURCK Industrial Connectivity Products
TURCK Industrial Connectivity Products General Accessories Liquid Tight Strain Relief Cable Glands Lock Nuts Page R2 - R4 Page R6 Snap-in Labels Strain Relief Cord Grips Page R5 Page R5 Protective Sleeving
More informationEJB Junction Boxes Dimensions Pg. 132
6F EJB Junction Boxes Dimensions Pg. 132 Application: EJB junction boxes are used in threaded rigid conduit systems in hazardous areas: As a junction or pull box To provide enclosures for splices and branch
More informationInstallation Notes TII Model 341 Protector
Installation Notes TII Model 341 Protector (ATT-IS PEC 32918) for MERLIN Communications System In Range Out of Building (IROB) Station Installation By Trained Technician Only WARNING: Failure to follow
More informationArmorConnect Power and Control Media
Selection Guide ArmorConnect Power and Control Media Bulletins 280, 888, 889, 898 2 Bulletin 280, 888, 889, 898 Power Media Product Overview Media Description Features Trunk Cable Cordset - Cable with
More informationPrecision temperature control/sensing
PROBE TEMPERATURE SENSORS TE200 Series Precision temperature control/sensing FEATURES: Thermistor or Precision RTD Various configurations available Selection of enclosures Custom laser etching available
More informationComputer Network Design Guide Existing Systems 1 / 6
COMPUTER NETWORK DESIGN GUIDELINE FOR EXISTING SYSTEMS DOCUMENT NUMBER: 16765 APPLICATION: ELEMENTARY, MIDDLE AND HIGH SCHOOL DATE OF ISSUE: 11-27-06 - First Issued NOTES: The attached guideline should
More informationUltima X5000 Rectangular Duct Mount Kit User Instructions
Ultima X5000 Rectangular Duct Mount Kit User Instructions MSA Kit 10176947 - Ultima X5000 316 Stainless Steel Parts List / Instructions Rectangular Gasket (1) Rectangular Duct Mount Base Plate (1) Base
More informationStandard Series Standard
Standard Series Standard Technical Data Coupler connector, cable connector and coupler connector rectangular housing Locking screw connection Protection IP 50 to IP 54 with conexil in the housing, flat-gasket
More informationEPIC Circular Connectors CIRCON M23 Series
The M3 connectors have many inherent features which offer application advantages and provide significant benefits for the customer. These features make it one of the most application friendly connectors
More informationesense Duct (-Disp) Conduit
Gas and Air Sensors Installation Manual esense Duct (-Disp) Conduit General Figure 1 The esense Duct Conduit with and without display The IAQ-sensor product esense Duct (for mounting in ventilation ducts)
More information62GB. Amphenol Series 62GB. Applications. Features
Applications Features 62GB Amphenol 62GB Series connectors are built to British Standard Specification BS 9522 F00 17 which is similar to US military specification MIL-DTL-26482. They are machined from
More informationInstalling a Power over Ethernet injector
Installing a Power over Ethernet injector AlphaEclipse StreetSmart and RoadStar signs The instructions in this document explain how to install/replace a Power over Ethernet (PoE) injector in a StreetSmart
More informationRinglock is a range of robust circular
Connectors is a range of robust circular connectors for industrial applications. It uses a metal bayonet coupling system for quick and reliable connections and thermoplastic bodies for low installed cost.
More informationCONDUIT SYSTEMS FOR ELECTRICAL WIRES AND CABLES: ANACONDA SPECIAL FITTING SOLUTIONS
ONDUIT SYSTMS FOR LTRIAL WIRS AND ALS: FITTING SOLUTIONS Fitting selection table Anaconda special fittings. Fitting Material Temperature ( ) Thread size range Shielding Approvals Protection Page Type Housing
More informationProviding flexible power supply and signal connection there, where it is needed even in hazardous areas for the Zones 1and 2.
e X L i n k exlink 7-pole / 6-pole + PE for Zone 1 and Zone 21 Providing flexible power supply and signal connection there, where it is needed even in hazardous areas for the Zones 1and 2. The exlink 7
More informationRT2Y Compact temperature switch intrinsic safety
ompact temperature switch intrinsic safety Main Features Excellent repeatability Fix dead band for control and alarm Resistant to accidental overtemperature Intrinsic safety Hazardous area 0, 1, 2 pplications
More informationFortiCam SD20 Mounting Guide
FortiCam SD20 Mounting Guide FortiCam SD20 Mounting Guide April 14, 2016 Copyright 2016 Fortinet, Inc. All rights reserved. Fortinet, FortiGate, FortiCare and FortiGuard, and certain other marks are registered
More informationPipe fittings and flanges, sockets for bayonet locks
Data Sheet 909750 (909725) Page 1/7 Pipe fittings and flanges, sockets for bayonet locks for temperatures up to 600 C for different fitting lengths simple installation and replacement pressure-tight sealing
More informationArecont Vision MegaView TM v1x Installation Manual
0 P a g e MegaView TM v1x Installation Manual Inside the box: A. Arecont Vision MegaView TM v1x B. Pack of four (4) wood screws and four (4) dry wall anchors C. Security L-key D. Mounting Template Mounting
More informationSIZE 1, 2 AND 3 POLYAMIDE PRE-DRILLED CONTROL STATIONS
SIZE, AND POLYAMIDE PRE-DRILLED CONTROL STATIONS 0986 00 0986 0 0986 0 0986 8 Size, and pre-drilled control stations with component fixed on the base* Compact enclosure, polyamide body and cover x M0 clearance
More informationFront Load Single Sensor
INFICON Front Load Single crystal sensors offer proven reliability and durability and have the best thermal stability of any sensor head on the market. The front load design allows for easy insertion of
More information4.5 Components for TV/SAT, telephone installations and Category DATATEL Series - TEL DATATEL Series - CAT5 DATATEL Series - TV/SAT
Components for TV/SAT, telephone installations and Category 5 DATATEL - TEL DATATEL - CAT5 DATATEL - TV/SAT 7 7 Components for telephone installations FIXED TELEPHONE SOCKETS Type RJ Socket 6/ surface
More informationOperating Instructions Drill rigs DRU400 DRA400
Operating Instructions Drill rigs DRU400 DRA400 Index 001 Original operating instructions 10988838 en / 12.05.2017 Congratulations! With a Hydrostress unit from TYROLIT you have chosen a tried and tested
More informationBS up.v.c SOIL, WASTE, VENT PIPES AND FITTINGS
Soil Waste & Vent Pipes Sweep Bend Sweep Bend with Inspection Opening 91¼ Soil Waste & Vent pipes for solvent weld connection to all fittings. Wall Length Mean Outside Thickness L in per M. Dia. D (mm)
More informationCool Drawer Dual Sensor
The Cool Drawer Dual Sensor is designed for use in critical processes where it is desirable to have a second crystal in the vacuum chamber. Water cooled, cast stainless steel sensor body, two Cool Drawer
More informationElectronic Digital Thermometer. Series SolarTemp and DiTemp
Electronic Digital Thermometer Series SolarTemp and DiTemp Digital and analogue - as ever accurate The measuring process The original concept for the format of the display was toservice considerations
More informationenglish Cable Entry Systems EMC Solutions innovative creative technology Product program A company of the icotek group
english 26 Cable Entry Systems EMC Solutions innovative creative technology Product program A company of the icotek group Customer requests and our constant involvement in ever changing markets is motivation
More informationPower-Over-Ethernet Weatherproof 18" x 16" x 8" Enclosure with Equipment Mounting Plate and Cooling Fans
Power-Over-Ethernet Weatherproof 18" x 16" x 8" Equipment Mounting Plate and Cooling Fans Applications and Features Applications: Remote Wireless LAN WiFi equipment installations using Power- Over-Ethernet
More informationCombi-System. Composition pipe Copipe
Combi-System Composition pipe Copipe no. Composition pipe Copipe white rolls DN 10 x 2.0 mm length per roll 50 m 150 10 54 length per roll 100 m 150 01 54 length per roll 200 m 150 02 54 DN 12 16 x 2.0
More informationCLAMPS & SUPPORTS CATALOG
ISO-900:2008 CLAMPS & SUPPORTS CATALOG Phone: 28 96 0900 Fax: 28 96 000 Email: sales@expotechusa.com Web: expotechusa.com 32 Cat. No. Page Cat. No. Page Cat. No. Page 07667... 6 03936... 2 038292... 0
More informationWARNING. General Information
Principal LED Sign Retrofit Installation Manual Kit Model: PL RT1 001 WARNING Retrofit Installation must only be performed by qualified personnel in accordance with the National Electric Code in the USA
More informationGeneral Specifications
General Specifications Model PR10 Inductive Conductivity Retractable fitting On-line measurements often present extra challenges, especially when routine maintenance is required. The PR10 is ideally suitable
More informationLimit Switch Connectors
CSM_LimitSwitch DS_E s (SC Series) Cabtire cables and flexible tubes with various diameters are used to connect machine tools and controllers with Limit Switches. To ensure the watertightness of the edges
More informationA Complete Floor Box System for Concrete
A Complete Floor Box System for Concrete Leviton has it all. From the floor box itself to the devices inside, our system delivers superior electrical power, AV and networking solutions. Delivering The
More informationStandard Hoods/Housings Han B Size 16 B
Standard / Han B Size 16 B Metal hoods/housings for industrial applications / 2 lever locking system 09 30 016 1520 1 x 21 09 30 016 0520 1 x 21 09 30 016 0521 1 x 29 angled entry 09 30 016 0663 2 x 21
More informationD-Sub SEaled subminiature D connectors, 2.54 mm pitch
SE D-Sub SEaled subminiature D connectors, 2.54 mm pitch Page Technical characteristics.......................................... 02 IP 67 versions with turned solder cups......... 04 IP 67 versions with
More informationRT2E Compact temperature switch Explosion proof
ompact temperature switch Explosion proof Main Features Excellent repeatability Dead band adjustment for regulation Fix dead band for control and alarm Light weight Explosion proof Hazardous areas 1, 2,
More informationFISCHER MINIMAX TM SERIES
TECHNICAL SPECIFICATIONS FISCHER TM SERIES Fischer Connectors SA All rights reserved Web version 1.0-03.2016 Changes without prior notice FISCHER TM SERIES KEY FEATURES The Fischer MiniMax Series increases
More informationMechanical accessories
Bearing box Part no. 01209010, 01209029 Part no. 01209010 01209029 Shaft size Ø 15 mm Ø 10 mm Shaft load max Radial: 250 N, Axial: 150 N Speed max 4000 rpm Protection class IP 64 according to IEC 60529
More informationIS-DM220/IR/HB IS-DM220
IS-DM220/IR/HB IS-DM220 Installation Guide Indoor/Outdoor Ver. 1.2 00P6NX223ZXSEA2 Table of Contents 1. Indoor Camera Installation... 3 1.1 Hard Ceiling... 3 1.2 In-Ceiling (T-Bar) Mounting... 13 1.3 4S
More informationPolycarbonate and ABS QLINE E
Spec-00410 D763.422.2211 763.422.2600 Polycarbonate and ABS QLINE E Polycarbonate and ABS QLINE E QLINE E, Type 4X INDUSTRY STANDARDS Polycarbonate Enclosure UL 8A Listed; Type 4, 4X, 6, 12, 13; File No.
More informationThread length (overall length) material
Cylindrical Proximity Sensor for Mobile Usage Designed and tested to keep your machines moving IP69k tested and certified for highest water resistance e1 type approval (according to automotive directive
More informationEthernet Setup Guide. Overview. Before you start. Tools and Equipment
Connect an Excite, RoadStar, or StreetSmart Sign to an Ethernet Network Overview These instructions walk you through connecting an Excite, RoadStar, or StreetSmart sign to an Ethernet network or directly
More information60W Power over Ethernet Waterproof Adapter PoE IEEE BT Single Port Injector for Outdoor Application
WWW.PHIHONG.COM 60W Power over Ethernet Waterproof Adapter PoE IEEE BT Single Port Injector for Outdoor Application Features Compliant with the IEEE802.3bt Standard Non-Vented Case with Mounting Bracket
More informationArlington Industries, Inc.
800/233-4717 FX 570/562-0646 rlington Industries, Inc. LEWY able Runway Support System able support system for either power or low voltage cable. For new construction or retrofit. Non-metallic. T205 New!
More informationAIR CUSHION TECHNOLOGY
AIR CUSHION TECHNOLOGY Air Speed 5000 V3 PX3 PARTS CATALOG VER. 20110822 P1001 A5000 V1/V2/V3 BELT (TEFLON) P1021 A5000 V1/V2/V3 SMART V1/V2 KNIFE (SLITTER BLADE) P1112 A5000 V1/V2/V3 RUBBER NIP ROLLER
More informationPolycarbonate and ABS QLINE E
763.422.2600 Spec-00410 E763.422.2211 Polycarbonate and ABS QLINE E Polycarbonate and ABS QLINE E QLINE E, Type 4X INDUSTRY STANDARDS Polycarbonate Enclosure UL 8A Listed; Type 4, 4X, 6, 12, 13; File No.
More informationEPIC LS1 Series Circular Power & Mixed Power Connectors
EPIC LS1 Series Circular Power & Mixed Power Connectors EPIC LS1 Circular and Mixed Power Connectors are designed to DIN specification EN61984 and have a standard M23 threaded connection housing. They
More informationSafety switches with separate actuator
Safety switches with separate actuator Selection diagram VF KEYD VF KEYD1 VF KEYD VF KEYD VF KEYD5 VF KEYD6 VF KEYD7 VF KEYD8 VF KEYD10 VF KEYD11 ACTUATORS FR FX FK FW 5 6 7 11 1 14 NC NC snap action snap
More informationPower-Over-Ethernet (PoE) Weatherproof 14 x12 x7 Enclosure with Mounting Plate. Model: NB Applications and Features
Power-Over-Ethernet (PoE) Weatherproof 14 x12 x7 Mounting Plate Model: NB141207-400 Applications and Features Applications: Remote Wireless LAN WiFi equipment installations using Power- Over-Ethernet Indoor
More informationv1.0 JL10 Series Circular Waterproof Connector Connector Training Module Copyright 2015 JAE Electronics, Inc.
v1.0 JL10 Series Circular Waterproof Connector Connector Training Module Copyright 2015 JAE Electronics, Inc. JAE JL10 Series Circular Waterproof Connector Application Examples Industrial machineries Servo
More informationSafety switches for hinged doors
C Safety switches for hinged doors Selection diagram FR FM FX FZ FK 18 7 9 snap action overlapped CONTACT BLOCKS 21 NC 1NO+ CONDUIT ENTRIES Threaded conduit entries (standard) With cable gland assembled
More informationZC-OH5 TAMPER-RESISTANT INDOOR/OUTDOOR HOUSING INSTRUCTION MANUAL FOR USE WITH GANZ ZC-D5000 SERIES MINIDOME CAMERAS
ZC-OH5 TAMPER-RESISTANT INDOOR/OUTDOOR HOUSING INSTRUCTION MANUAL FOR USE WITH GANZ ZC-D5000 SERIES MINIDOME CAMERAS Please carefully read and observe all instructions and warnings contained in this manual
More informationLMH-100 Installation Instructions
Ritron, Inc. 505 West Carmel Drive Carmel, IN 46032 P.O. Box 1998 Carmel, IN 46082 Ph: 317-846-1201 Fax: 317-846-4978 Email: ritron@ritron.com web: www.ritron.com LMH-100 Installation Instructions Ritron
More informationSafety switches with separate actuator
4 Safety switches with separate actuator Selection diagram VF KEYD VF KEYD1 VF KEYD VF KEYD VF KEYD VF KEYD6 VF KEYD VF KEYD10 ACTUATORS CONTACT BLOCKS 6 snap action overlapped FR FX FK FW 0 1 4 NC NO+1NC
More informationLimit Switch Connectors
CSM_LimitSwitch_Connector_DS_E Connectors (SC Series) Cabtire cables and flexible tubes with various diameters are used to connect machine tools and controllers with Limit Switches. To ensure the watertightness
More informationEE360. High-End Moisture in Oil Transmitter. Typical applications. Features EE360 EE360. (+34)
is dedicated for reliable monitoring of lubrication, hydraulic and insulation oils as well as diesel fuel. In addition to highly accurate measurement of water activity (a w ) and temperature (T), calculates
More informationenglish Cable Entry Systems EMC Solutions innovative creative technology Product catalogue A company of the icotek group
english 27 Cable Entry Systems EMC Solutions innovative creative technology Product catalogue A company of the icotek group Ideas move Ideas move the world icotek GmbH is a privately held company in the
More informationRD-44 Audio Network Control Panel
RD-44 Audio Network Control Panel Introduction: The RD-44 is designed to control the audio functions and sources of the MRD-70 marine radio and the MZ-100 DSP Zone Amplifier. With versatile mounting options,
More informationMOTION MASTER SENSOCONTROLLER - PRODUCT SPECIFICATION S MMS WA-5, SU-5, EXP-5 WA-5 SU-5 EXP-5
MOTION MASTER SENSOCONTROLLER - PRODUCT SPECIFICATION S MMS WA-5, SU-5, EXP-5 VER5.2 WA-5 SU-5 EXP-5 GENERAL DESCRIPTION Belcatec Design Inc. designs and manufactures Motion Master Sensocontroller safety
More informationRL70 INDUSTRIAL FLUORESCENT TUBE LIGHT
32 RL70 INDUSTRIAL FLUORESCENT TUBE LIGHT FEATURES: RL70 CE Series - For compact fluorescent lamps and electronic ballast (CE) RL70 E Series - For standard bi-pin T5, T5HO and T8 lamps, electronic ballast
More informationMICHIGAN DEPARTMENT OF TRANSPORTATION
MICHIGAN DEPARTMENT OF TRANSPORTATION SPECIAL PROVISION FOR GROUNDING, BONDING, LIGHTNING PROTECTION AND SURGE PROTECTION FOR INTELLIGENT TRANSPORTATION SYSTEM EQUIPMENT ITS:CLC 1 of 6 APPR:MDW:JVG:06-08-18
More informationContinuous level measuring system NB 3000 Selection list
Table of contents Page Overview 2 ------------------------------------------------------------------------------------------------------------------- Specifications 3 -------------------------------------------------------------------------------------------------------------------
More informationDM28 - Economical Digital Process and Strain Gauge Panel Meters
DM28 - Economical Digital Process and Strain Gauge Panel Meters TRANSDUCERS Easily scaled in any engineering units from -19999 to 99999 Large 18mm (.71 ) high red or green display Front panel MIN, MAX
More informationICS Entrance Management Sign Installation Guide. Version 1.0
ICS Entrance Management Sign Installation Guide Version 1.0 Thank you for purchasing your new ICS Entrance Management System (EMS) from Innovative Control Systems, Inc. Installation Overview This document
More informationProbe station system
Probe station system Manufacturer: Micromanipulator Mode: 450PM-HR Descriptions: The Model 450PM 8 probe station offers stable and reliable probing performance. It is based on a design of Micromanipulator
More informationExplosionproof Meter Housings
METER HOUSINGS Explosionproof Drilled and tapped to specification, attach layout sheet. Dimensions are internal. XJDGCH N4 XJDFGCH N4 4 1/8 x 4 1/8 X 3 XJMCGCH N4 6 3/4 x 6 3/4 x 3 XJTGCH N4 XJTFGCH N4
More informationMICHIGAN DEPARTMENT OF TRANSPORTATION
MICHIGAN DEPARTMENT OF TRANSPORTATION SPECIAL PROVISION FOR GROUNDING, BONDING, LIGHTNING PROTECTION AND SURGE PROTECTION FOR INTELLIGENT TRANSPORTATION SYSTEM EQUIPMENT ITS:CLC 1 of 5 APPR:LWB:DBP:07-31-13
More information33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application
33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application Features Compliant with the IEEE802.3at Standard -40 to +60 C Temperature Range Diagnostic LEDs Full Protection
More information8 Submersible Motors Hi-Temp 75
Applications These motors are built for dependable operation in vertical 8 diameter or larger wells, in applications with higher temperature, higher thrust or low flow. Basic Features Able to operate in
More informationVandal-proof latching action switch MSM LA
Product Manual Vandal-proof latching action switch MSM LA CONTENTS 1 PRODUCT DESCRIPTION... 2 2 TECHNICAL DATA AND DIMENSIONAL DRAWINGS... 2 2.1 Technical Data... 2 2.2 Dimensional Drawings... 5 2.3 Hole
More informationGARDEN SPEAKERS GS4 INSTALLATION GUIDE RevA-GS4-SpkManual.indd 1
GARDEN SPEAKERS GS4 INSTALLATION GUIDE 9901210-RevA-GS4-SpkManual.indd 1 parts List ground stake mounting 2 GS4 Satellite Loudspeakers with attached wall-mount brackets 2 Mounting Stakes (Optional) 2 Pairs
More informationKT Inserts, small. Product description. Assembly. Specification KT grey. Specification KT black
KT Inserts, small Description Type Order No Order No Clamping range PU grey black BTK BTK 41251 41351 Blind insert 10 KT cable inserts small are used with the following cable entry frames: KEL - Page 6-13
More informationFDS / FDS-R / FDS-PS
FDS / FDS-R / FDS-PS USER MANUAL For use with 120V 60Hz input. Output is 120V 60Hz at 5amps 600W MAX. switched. ETL LISTED Conforms to UL STD 1241 3091594 79-15167-00 REV. A www.fiberstars.com Page 1 of
More informationSADDLES & SNAP-ON SADDLES
SADDES & SAP-O SADDES When Assembling Spears Saddles to PVC pipe, Spears anufacturing Company recommends Spears PVC-19 Solvent Cement and Spears Primer-68/Primer-70 or equivalent. Although good connections
More informationPureFlow Zero Lead PEX manifold plumbing systems Number one rated PEX plumbing manifolds
PureFlow PureFlow PureFlow Zero Lead PEX manifold plumbing systems Number one rated PEX plumbing manifolds 119 Stock Qty Approx. Zero Lead PEX Manifold Plumbing Systems ZERO LEAD MANABLOC -COMPRESSION
More informationCMS 603ICT BM. Optimised for Installation
Product Information Document Full range ceiling loudspeaker for installation applications 60 Watts continuous, 240 Watts peak power 6" ICT (Inductive Coupling Technology) point source driver for extended
More informationThe Rosemount 356 Nuclear Connector
Product Data Sheet 00813-0200-4856, Rev AE March 2013 Rosemount 356 The Rosemount 356 Nuclear Connector Easy-to-install connector for use outside containment Die cast zinc or stainless steel connector
More informationBLÜCHER Compact. The flexible drains for easy solutions in housing and commercial applications