1 CIRCUIT DIAGRAM + - TANDARD FR-LD FR FEATURE Designed for extreme environmental condition Large terminals for easy connections Constructed for lowest temperature rise thus longer life 'O' Energiser for higher magnetic linkage Wider voltage variation Bottom Cable entry to avoid rain or process fluid entering into the termination area. For ease of operation and maintenance LED can be provided to confirm avalibility of voltage to the olenoid terminals Dual gasket PECIFICATION ize II - 8 mm, III - 4 mm, IV - 4 mm Voltage 6 V, 2 V, 24 V, 48 V, 0 V, 20 V, 220 V, 256 V Current 50 Hz, 60 Hz, DC, 50 Hz/ 60 Hz/ DC Enclosure Cable Entry M25 X.5, Adopted to M20 X.5 or /2" NPT Material Aluminum Cast, Polyester Powder Coat, Colour Blue tainless teel Cast Options urge uppressor (), Fully Rectified (FR), LED (LD), Low Power (LW), Menual Reset (MR) Power Refer to table "Power" on page 43A Insulation Class Class H Weather Protection IP67, IP67 M Optionally IP68 Approval INDIAN, ATEX,, IECEx, CCOE, DGM, IL Pick Up Voltage 70% of Rated Volatge Drop Down AC : 65% of Rated Voltage, DC : 30% Rated Voltage Voltage Variation Refer to Voltage Variation table on page 43B Duty Cycle 00% (ED) Ambient Temprature Refer to Ambient temperature table on page 429C DGM applied for WEIGHT IN kg ize Al II III IV APPLICATION INDOOR OUTDOOR 43
2 Voltage olenoid ize Core Dia II 8 ü III 3 ü III 4 üüü IV 4 ü 2 II 8 ü ü III 3 ü III 4 üüü IV 4 ü 24 II 8 ü ü III 3 ü III 4 üüü IV 4 ü 48 II 8 ü III 3 III 4 üüü IV II 8 ü ü III 3 III 4 ü II 8 ü ü III II 8 ü ü III 4 IV 4 tandard üoptional Available 2 Only for DC Current 3 hould be Opted for 3/2 & 5/2 pilot operated valves Power (VA) TANDARD ize Current tandard Power W, VA I AC 6, 2 DC 8, 8 II AC 3, 3 DC 3, 3 III AC 6, 2 DC 8, 8 43A
3 OLENOID ORDERING III-24V-DC-87-CO--LD-LW-H-07 III 24V DC IZE VOLTAGE CURRENT ENCLOURE IZE II III IV 6V 2V 24V 48V 0V 20V8 220V9 50Hz 60Hz78 50/60 Hz/DC DC INDIAN ATEX INMETRO ATEX & IEC Ex DGM + CCOE MN CABLE ENTRY(F) /2" NPT (F) M20X.5 3/4" NPT (F) M25X N 87M 87NL MATERIAL AL CAT, IP67/ IP67 M CAT, IP67/ IP67 M AL CAT, IP68, INDIAN CAT, IP68, INDIAN CO A A CO 256V PEO, CCOE PE LD LW5 PECIAL VERION PECIAL VERION INULATION FEATURE NIL FULLY RECTIFIED URGE UPPREOR FR5 FEATURE 2 NIL LATCH MANUAL REET OFF LC2 ML2 VA 0.4 LW0.4.8 LW2 CLA CLA H MANUAL REET ON LED MR2 LD 3.5 LW3.5 5 LW5 8 LW8 5 LW5 20 LW20 30 LW30 NOTE : Do not specify 2 Voltage 24V, 0-20V, V current Hz/ DC power standard size II or II VOLTAGE VARIATION (For Continuous Duty only) 5 olenoid suitable for 50 Hz/ 60 Hz/ DC current, elect special version FR 6 Refer Power table on page 430A V 50 Hz olenoid can be used for 0V 50 Hz,20V 60 Hz V olenoid can be used for V 50 Hz, 240V 60 Hz Rated Volatge Operating Voltage 6 4.8V to 7.2V 2 9.6V to 4.4V V to 28.8V V to 57.6V V to 32V V to 264V V to 280V 43B
4 MARKING Temperature Class ATEX, IECEx INDIAN, DGM, CCOE Ambient II 2GD IIC T6 Gb - 60 C < Ta < XX C Ex tb IIIC T80 C Db IP67 II 2GD IIC T5 Gb - 60 C < Ta < XX C Ex tb IIIC T95 C Db IP67 II 2GD IIC T4 Gb - 60 C < Ta < XXX C Ex tb IIIC T30 C Db IP67 II 2GD IIC T3 Gb - 60 C < Ta < XXX C Ex tb IIIC T55 C Db IP67 IIC T6 Gb - 60 C < Ta < XX C Ex tb IIIC T80 C Db IP67/ IP67 M/IP68 IIC T5 Gb - 60 C < Ta < XX C Ex tb IIIC T95 C Db IP67/ IP67 M/IP68 IIC T4 Gb - 60 C < Ta < XXX C Ex tb IIIC T30 C Db IP67/ IP67 M/IP68 IIC T3 Gb - 60 C < Ta < XXX C Ex tb IIIC T55 C Db IP67/ IP67 M/IP68 IIC T6 IP67-60 C < Ta < 70 C Ex tb IIIC T80 C Db IP67 IIC T5 IP67-60 C < Ta < 70 C Ex tb IIIC T95 C Db IP67 IIC T4 IP67-60 C < Ta < 00 C Ex tb IIIC T30 C Db IP67 IIC T3 IP67-60 C < Ta < 00 C Ex tb IIIC T55 C Db IP67 AMBIENT TEMPERATURE IZE MAX. MAX. AMBIENT TEMPERATURE C T6 T5 T4 T3 III II IV e.g. () olenoid ize III, Power 8W (2) olenoid ize II, Power 30W ATEX approval II2 GD as per INDIAN approval IIC T6 Gb Ex t IIC T80 IIC T3 Gb Db IP67 Ex t IIC T55 Db IP67-60 C Ta 60 C -60 C Ta 70 C 43C
5 Approval certifying Agencies reference Number INDIAN KLPL BI CCOE/ PEO DGM ATEX DNV DNV 2 ATEX 2883X IECEx DNV IECEx, DNV X RU C-IN. ГБ08.B.000 DIMENION OLENOID TYPE : 87 M25X III 3 III 4 M20X.5, /2" NPT(F) (With Adopter) II 8 IV III 3 III 4 II 8 IV 4 OBELETE PRODUCT AND IT INTERCHANGEABILITY Replace olenoid code 87N or 87M along with Guide and Plunger assembly Replace olenoid code 87 or 87M along with Guide and Plunger assembly olenoid code 39 replace with olenoid code 87M 43D
VALVES Inline 3/2-, 5/2- & 5/3 Spool valves electromagnetic actuated, indirectly controlled G 1/4, 1/4 NPT, G 1/2, 1/2 NPT
975 Inline 3/-, 5/- & 5/3 Spool valves electromagnetic actuated, indirectly controlled G /, / NPT, G /, / NPT For single and double operated actuators Closed crossover design Add-on manual override Rectified
More informationOperating pressure (bar) kv factor (m 3 /h) *3)
/ way poppet valves (stainless steel) electromagnetic actuated, directly controlled G /8, G /4 or /4 NPT Working from 0 bar up Assembled free of oil and grease Suited for fine vacuum down to,33 0 - mbar
More information26360, 80207, 3/2, 5/2 & 5/3 Indirect solenoid actuated spool valves
66, 87, /, 5/ & 5/ > > Port size: G/ & G/ > > Compact design > > Easily interchangeable solenoid > > tandard manual override > > ll valves available with Ex protected coils (TEX or other international
More information97105 Inline 3/2, 5/2 & 5/3 way spool valves electromagnetic actuated, indirectly controlled G1/4, 1/4 NPT, G1/2, 1/2 NPT
70 Inline 3/, / & /3 way spool valves electromagnetic actuated, indirectly controlled G/, / NPT, G/, / NPT Main application: single and double operated actuators TÜV-approval based on type examination
More informationLoads and Motor Switchgears
5 Loads and Motor Switchgears Motor Switches BLK Series Explosion-proof Motor Switches to -CENELEC -IEC -NEC Can be used in Zone 1 and Zone 2 Zone 21 and Zone 22 Class I, Zone 1 and Zone 2 Class I, Division
More information97105 Inline 3/2, 5/2 & 5/3 spool valves electromagnetic actuated, indirectly controlled G 1/4, 1/4 NPT, G 1/2, 1/2 NPT
705 Inline 3/, 5/ & 5/3 spool valves electromagnetic actuated, indirectly controlled G /, / NPT, G /, / NPT For single and double operated actuators Valves for safety systems up to SIL (IEC 6508) Crossover-free
More informationM C. Ex d M-0... control, monitoring and signalling devices
Ex d M-0... control, monitoring and signalling devices M-0 M-0 series control, monitoring and signalling devices are installed as external accessories on Cortem 'Ex d' enclosures used in any industrial
More informationOperating pressure (bar)
/ poppet valves electromagnetic actuated, directly controlled G /4, /4 NPT, G /, / NPT or flanged with NAMUR Interface Main application: single operated actuators for plants Valves for safety systems up
More informationOperating pressure. N/en/en
660, 8007 NAMUR /, / & / spool valves electromagnetic actuated, indirectly controlled G / and NAMUR interface For single and double operated actuators Manual override with and without detent Simple design
More informationOperating pressure. N/en/en
660, 8007 NAMUR /, / & / way spool valves electromagnetic actuated, indirectly controlled G / and NAMUR interface For single and double operated actuators Manual override with and without detent Simple
More information80265 series, 3/2 Indirect solenoid actuated poppet valve
> > Port size: G/... G > > High flow rate > > Optionally air pilot operated > > High repeatability of switching time > > Variable valve solenoid combination Technical features Medium: Compressed air, filtered,
More information95100, 2/2 (stainless steel) Direct solenoid actuated poppet valves
9500, / (stainless steel) > > Port size: G/8, G/4, /4 NPT > > Working from 0 bar up > > Assembled free of oil and grease > > Suited for fine vacuum down to,33 0 - mbar > > For a.c. solenoid systems with
More information21023, 21025, 2/2 Direct solenoid actuated poppet valves
03, 05, / > > Port size: G/4, G/ > > Working from 0 bar up > > Suitable for mediumhigh vacuum down to.33 0 - mbar l/s > > Compact design > > Valves and solenoids are ATEX approved. Additional international
More informationTerminal Boxes Series 8118
> Enclosure made of glass fibre reinforced polyester resin > sizes available > Terminals and cable glands fitted to order > Enclosure design with integrated metal bracket for metal cable glands. > Degree
More informationGrounding Systems / Ground Monitoring Device Series 8146/5075 and 8125/5071
www.stahl.de > Monitored electrostatic grounding of tank containers and drums during loading > Continuous monitoring of correct grounding > Robust design > Weather-protected plastic enclosure (IP66) or
More informationInstallation Equipments
Installation Equipments BCZ8 Series Explosion-proof and Socke ts to -CENELEC -IEC -NEC Can be used in Zone 1 and Zone 2 Zone 21 and Zone 22 Four enclosure types; Four current ratings (1A, 32A, 3A, 12A);
More informationHERION SERIES Indirect solenoid actuated spool valves
HERION SERIES Indirect solenoid actuated spool valves for single and double acting actuators with NAMUR interface /2, /2, /, NC/APB, G/, G/2 Valves for safety systems up to SIL (IEC 08) Crossover-free
More information97105 NAMUR, 3/2, 5/2 & 5/3 Indirect electromagnetic actuated spool valves
970 NAMUR, /, / & / > > Port size: / or / ISO G/NPT > > Main application: single and double operated actuators > > TÜV-approval based on type examination DIN EN, DIN 9 and IEC 08 > > Valves for safety
More informationFlow. Flow. N/en
/ poppet valves electromagnetic actuated, directly controlled G /4 or /4 NPT Working from 0 bar up Short switching times Suited for fine vacuum down to, 0 - mbar For a.c. solenoid systems with integrated
More informationTechnical features. 12/ f. N/en
/, / & / way spool valves electromagnetic actuated, indirectly controlled G /, / NPT, G /, / NPT or flanged with NAMUR interface Main application: single and double operated actuators TÜV-approval based
More informationSensor boxes SRBE Key features and product range overview
Sensor boxes SRBE Sensor boxes SRBE Key features and product range overview Function Sensor boxes SRBE are used for electrical feedback and control of the position of process valves actuated using pneumatic
More informationLinear Luminaire with LED Series EXLUX 6002/1 Version IIB+H2
> For use in hazardous areas with gas group IIB+H 2 > Latest LED technology with a high luminous efficacy and a long service life > As pendant light fitting or pole mounted light fitting > Central locking
More informationSales: Malux Finland Oy, P.O.Box 69, FI Porvoo, Phone , Fax ,
E X - P O W E R C I R C U I T B R E A K E R S Up to 630 A CEAG power circuit breakers enable making or breaking of circuits under normal operating conditions as well as cutting in, briefly conducting and
More informationTubular Light Fitting with LED Series 6036
> Extremely robust luminaire design for rough ambient conditions > Very lightweight and vibration resistant LED light fitting > Extremely long service life due to LED used > High power LEDs including driver
More informationSeries 95000, 2/2 Direct solenoid actuated poppet valve
> Port size: /4 (ISO G or NPT), G/ > Working from 0 bar up > Short switching times > Suited for fine vacuum down to,33 x 0 - mbar > For a.c. solenoid systems with integrated rectifier (40... 60 Hz) > Variable
More informationLinear Luminaire with LED Series 6412/5
> For use in Zones 2, 21 & 22 > Latest LED technology with a high luminous efficacy and a long service life > Extra flat version for low mounting depth > Powder-coated sheet-steel or brushed stainless
More informationLinear Luminaire with LED Series 6012/5
> For use in Zones 1 & 2, 21 & 22 > Latest LED technology with a high luminous efficacy and a long service life > Extra flat version for low mounting depth > Powder-coated sheet-steel or brushed stainless
More information2.2. Ex-Linear LED light fittings. ellk/m 92 LED 400/800 / ellk/m 92 LED 400/800 V-CG-S / NE / NIB-HT / NIB-CSA (Zone 1, 2, 21, 22)
. Ex-Linear LED light fittings ellk/m 9 LED 400/800 / ellk/m 9 LED 400/800 V-CG-S / NE / NIB-HT / NIB-CSA (Zone 1,, 1, ) The efficient solution for your explosion-protected lighting concept The explosion-protected
More informationCradle relay AC. Electrical data Operating data (coil circuit) U N. Explosion protection Marking ATEX. II 2G Ex db e IIC Gb I M2 Ex db e I Mb I N
Cradle relay AC Cradle relay for alternating voltage, neutral, monostable. High-quality cradle relays for AC are installed as encapsulated flameproof elements in the MODEX enclosure. The IP 66 protection
More informationEmergency Luminaire for Fluorescent Lamps Series EXLUX 6009
> As wall, ceiling and pendant light fitting or pole mounted light fitting > Version with 2 lamps: 18 W and 36 W > Central locking > All-pole disconnection via N/C switch when opening light fitting or
More information97100 NAMUR series, 3/2 & 5/2 Indirect solenoid actuated spool valve
9700 NAMUR series, / & / > > Port size: /4 (ISO G or NPT), NAMUR Interface > > Crossover-free switching > > Main application: Single and double acting actuators > > / way valve usable as / way valve >
More informationGeneral Specifications
General Specifications Model MLX Loop Powered Process Indicator GS 60A02S01-01E-A The Model MLX Loop-Powered Process Indicator receives DC current signals from electronic transmitters and indicates process
More informationPneumatic Control/Feedback
897 /Feedback Type 897 can be combined with... Compact design Integrated pilot valve with manual override Internal control air routing Automatic end position adjustment With ATEX II cat. G/D and cat. D/G
More information26360, Inline. Technical data. Ordering information See page 2. For connector plugs see page 2 and data sheets N/en /2 5/2.
66, 87 Inline / and 5/ directional control valves NG 6 and Operation: elektromagnetic Indirectly controlled soft seal spool valves Port size: G /4 and G / For single and double operated actuators Manual
More informationSMC Australia New Zealand IECEx & ATEX Compliant solenoid valves Rev 1.0
Eplosion Proof 3, 5 port solenoid valves IECEX compliant solenoid valves for Australia and New Zealand VF1/3/5000 Series XAR4001, XAR4002, XAR4003 VP3/5/700 Series XAR4010, XAR4011, XAR4012 VFN2000/200
More information97105 NAMUR. Technical data. Ordering information and accessories See page 6 and 7
90 NAMUR /, / and / directional valves Actuation: electromagnetic Indirectly controlled soft seal spool valves Port size: G /, / NPT, G /, / NPT NAMUR-interface For single and double operated actuators
More informationThe iwap107 supports 100/1000Base-T, offering a significant increase in speed over the older fast Ethernet standard.
iwap107 Zone 1 Universal Access Point Enclosure Wireless access point enclosure system Intrinsically safe RF outputs Explosion proof ATEX / IECEx Zone 1 certified US & Canada Class I Div 1 / Zone 1 certified
More informationACExC 01.2 Modbus TCP/IP
General information ACExC 01.2 actuator controls for controlling multi-turn actuators of the SAEx/SAREx.2 type range and part-turn actuators of the SQEx/SQREx.2 type range with interface. Features and
More informationYT-870 / 875 Series. Rotork YTC Limited VERSION 1.06
PRODUCT MANUAL Rotork YTC Limited VERSION 1.06 Contents 1 Introduction... 3 1.1 General Information for the users... 3 1.2 Manufacturer Warranty... 3 1.3 Explosion Proof Warning... 4 2 Product Description...
More informationVALVE POSITION INDICATOR. Product sheet
VALVE POSITION INDICATOR Product sheet Netherlocks Valve Position Indicator (VPI) seamlessly provides an overview of positions of the manual valves within your plant network that saves costs, time and
More informationIECEx Certificate of Conformity
INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Certificate No.: Status: IECEx FTZU 14.0004X Current
More informationTechnical features. N/en
/, 5/ & 5/ spool valves electromagnetic actuated, indirectly controlled G /, / NPT, G /, / NPT or flanged with NAMUR interface For single and double operated actuators Exhaust air recirculation at way
More information24011 series, 3/2 Direct solenoid actuated poppet valve
0 series, / > Port size: / (ISO G or NPT), NAMUR Interface > Add-on manual override or inductive limit switches on request > Main application: Single and double acting actuators > TÜV-approval based on
More information3/2 Directional control valves Direct solenoid operated poppet valves Internal thread G 1/2, 1/2 NPT or flanged with NAMUR interface
9805 / Directional control valves Direct solenoid operated poppet valves Internal thread G /, / NPT or flanged with NAMUR interface Main application: single operated actuators for plants TÜV-approval based
More informationOperating and monitoring systems Panel PC SERIES 400 Device platform SHARK ET-498-2TX
Panel PC, AMD GX or Core i7, 21.5" display, sunlight- readable 1000 cd/ m² Rugged design:, shock, vibration and seawater- proof, temperature range - 40 C to +65 C Full HD resolution (1920 x 1080) Optional
More information2.3. Ex-Linear light fittings for fluorescent lamps. ellk W 58 W / ellm W 36 W (Zone 1, 2, 21, 22)
.3 Ex-Linear light fittings for fluorescent lamps ellk 9 18 W 58 W / ellm 9 18 W 36 W (Zone 1,, 1, ) The classic lighting solution in hazardous areas The ellk 9 linear luminaire series for fluorescent
More informationXLF. Ex d. - Zones 1, 2, 21, 22 - Obstruction warnings - Stroboscopic lights - Single or double fixtures - Low wind resistance
XLF - Zones 1, 2, 21, 22 - Obstruction warnings - Stroboscopic lights - Single or double fixtures - Low wind resistance Polycarbonate Fresnel lens Fixture without Fresnel lens Painted aluminium body E.2
More informationSolConeX extra-low voltage flange socket
SolConeX extra-low voltage flange socket Operating instructions Additional languages www.stahl-ex.com Contents 1 General Information...3 1.1 Manufacturer...3 1.2 Information regarding the operating instructions...3
More informationVS102 Electronic Vibration Switch
VS102 Electronic Vibration Switch PVTVM, Inc. sales@pvtvm.com www.pvtvm.com 0 PVTVM-VS102-CATALOG-E-A-1 Table of Contents VS102 Electronic Vibration Switch... 1 Introduction... 1 Applications... 1 Features...
More informationOperating and monitoring systems Thin Client SERIES 500 Device platform EAGLE PM ET-556-TX
Thin Client for panel mounting, 19" display, 1280 x 1024 pixels Zone 1, 2, 21, 22, can be installed in hazardous areas without additional enclosure All-round degree of protection, resistive foil touch
More informationWirelessHART Adapter SWA70
Technical Information WirelessHART Adapter SWA70 Intelligent WirelessHART interface module for connection to 4...20 ma/hart devices Application WirelessHART Adapter SWA70 is a battery powered, interface
More informationT EN TROVIS Electropneumatic Positioner
T 8484-1 EN TROVIS 3730-1 Electropneumatic Positioner Application Single-acting positioner for attachment to pneumatic globe and rotary valves. Self-calibrating, automatic adaptation to valve and actuator.
More informationPneumatic Control/Feedback
897 /Feedback Type 897 can be combined with... Compact design Integrated pilot valve with manual override Internal control air routing Bright LED position indicator Automatic end position adjustment Type
More informationDräger Polytron 8200 Stationary gas detector (CatEx)
Dräger Polytron 8200 Stationary gas detector (CatEx) Quick, reliable and cost-effective detection of combustible gases and vapours in the ambient air: the microprocessor-based transmitter is the result
More informationSeries 3730 Type Electropneumatic Positioner
Series 3730 Type 3730-0 Electropneumatic Positioner Application Single-acting or double-acting positioner for attachment to pneumatic control valves Set point Travel 4 to 20 ma 5.3 to 200 mm The positioner
More informationIECEx Certificate of Conformity
IECEx Certificate of Conformity INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Certificate No.:
More informationSeries 3730 Type Electropneumatic Positioner
Series 3730 Type 3730- Electropneumatic Positioner Application Single-acting or double-acting positioner for attachment to pneumatic control valves. Self-calibrating, automatic adaptation to valve and
More informationMagnetic float switch For vertical installation Model FLS
Level measurement Magnetic float switch For vertical installation Model FLS WIKA data sheet LM 30.01 for further approvals see page 3 Applications Level measurement for almost all liquid media Pump and
More informationOperating and monitoring systems Operator Interface SERIES 300 Device platform EAGLE OS MT-316-TX
Operator Interface Operator Station 10" display, 800 x 600 pixels with resistive foil touch screen 12 function keys Zone 2, 22 and Division 2, optional GMP- compliant enclosure Data is transmitted via
More informationCoil Type 3009M. This document cannot be modified without the approval of the Certification Institute 1/4
Coil Type 3009M Coil Type 3009M UE DECLARATION OF CONFORMITY 1/4 Coil Type 3009M COIL 3009M II 2G Ex mb IIC Tx Gb II 2D Ex tb IIIC Tx C Db to be used in potentially explosive atmosphere We, AMISCO S.p.A.,
More information26360, NAMUR. Technical data
66, 87 NAMUR /-, /- and / directional control valves Operation: elektromagnetic Indirectly controlled soft seal spool valves Port size: G/ NAMUR-Interface For single and double operated actuators Manual
More informationFlow Measurement SITRANS F M. Transmitter MAG 6000 I/6000 I Ex de. 3/46 Siemens FI
Overview The MAG 6000 I/6000 I Ex de is a microprocessorbased transmitter with a buildin alphanumeric display in several languages. The transmitters evaluate the signals from the associated electromagnetic
More informationGrounding Monitoring Device Series 8485
www.stahl.de > Controlled electrostatic grounding of road tankers and rail cars during loading > Continuous monitoring of correct grounding > The object recognition prevents potential operator errors (with
More informationConveyor Belt Alignment Switches from IDEM
Conveyor Belt Alignment Switches from IDEM Data Sheet Die-Cast Models Python Line Series Stainless Steel Models Using Conveyor Belt Alignment Switches Application: Conveyor Belt Alignment switches are
More informationOperating and monitoring systems Operator Interface SERIES 300 Device platform EAGLE OS ET-306-FX
Operator Interface Operator Station 10" display, 640 x 480 pixels with resistive foil touch screen 12 function keys, 10 soft keys, 30 alphanumeric keys Zone 1, 2, 21, 22 and Division 2, optional GMP- compliant
More informationTechnical Data. General specifications. Rated operating distance s n 3 mm
0102 Model Number Features Direct mounting on standard actuators Compact and stable housing with terminal compartment connection ATEX & IECEX certifications Usable up to SIL 2 acc. to IEC 61508 Weatherproof
More informationEx emergency pull-wire switches Ex ZS 71
Features/Options: Ex zone 1 and 21 Metal enclosure 2 contacts Wire length up to 35 m Small design Release by push-button (VD) Available without unlocking mechanism (per EN 60947-5-1) Wire pull and breakage
More informationOperating and monitoring systems Panel PC SERIES 400 Device platform EAGLE PM ET-436-TX
Panel PC for panel- mounting, quad core ATOM E3845 15" display, 1024 x 768 pixels with resistive foil touch screen 8 function keys Zone 1, 2, 21, 22 und Division 2, can be installed in hazardous areas
More informationGeneral Specifications
General Specifications Model MLX Loop Powered Process Indicator GS 60A02S01-01E-A The Model MLX Loop-Powered Process Indicator receives DC current signals from electronic transmitters and indicates process
More informationThroughwiring. single-ended. twin-ended
Ordering details ellk 9... 18 W - 58 W Ordering details Type Version Terminals Throughwiring single-ended Throughwiring twin-ended Cable gland/ thread Threaded plug Blanking plug Order No. ellk 18/18 ellk
More informationProviding flexible power supply and signal connection there, where it is needed even in hazardous areas for the Zones 1and 2.
e X L i n k exlink 7-pole / 6-pole + PE for Zone 1 and Zone 21 Providing flexible power supply and signal connection there, where it is needed even in hazardous areas for the Zones 1and 2. The exlink 7
More informationSupplementary Components WirelessHART products
Overview SITRANS AW200 WirelessHART adapter The SITRANS AW200 WirelessHART adapter is a batterypowered communication component, which integrates HART and 4 to 20 ma field devices into a WirelessHART network.
More informationReed sensor For bypass level indicators Model BLR
Level measurement Reed sensor For bypass level indicators Model BLR WIKA data sheet LM 10.04 for further approvals see page 3 Applications Sensor for the continuous level measurement of liquids in bypass
More informationSolConeX Wall-Mounted Socket, 16 A
SolConeX Wall-Mounted Socket, 16 A Operating instructions Additional languages www.stahl-ex.com General Information Contents 1 General Information...2 1.1 Manufacturer...2 1.2 Information Regarding the
More informationEX-PROOF THERMAL ANALOGUE CAMERAS IN COMPACT DESIGN EC-840S-TIC-19A - Series
EX-PROOF THERMAL ANALOGUE CAMERAS IN COMPACT DESIGN EC-840S-TIC-19A - Series The explosion protected EC-840S-TIC thermal cameras are perfect for effective video surveillance and process control in harsh
More informationEX-PROOF HD CAMERA IN A COMPACT DESIGN EC-910-AFZ-Full HD IP 10 x Zoom
EX-PROOF HD CAMERA IN A COMPACT DESIGN EC-910-AFZ-Full HD IP 10 x Zoom The compact Full HD explosion-protected EC-910-AFZ Series is designed for effective video surveillance and process control in harsh
More information11W & 22W: Ex d e mb IIC T6 Gb, Ex tb IIIC T85 C Db II 2GD ABS Assessed: #11-LD PDA
Application: The Dialight SafeSite LED Bulkhead luminaire with its low profile, rugged design ensures long life and high reliability for a wide variety of Hazardous Area applications. Offered in 11W, 22W
More informationGrounding Monitoring Device Series 8485
www.stahl.de > Controlled electrostatic grounding of road tankers and rail cars during loading > Continuous monitoring of correct grounding > The object recognition prevents potential operator errors (with
More informationSensor boxes SRBC. Festo core product range Covers 80% of your automation tasks
Sensor boxes SRBC q/w Worldwide: Superb: Easy: Festo core product range Covers 80% of your automation tasks Always in stock Festo quality at an attractive price Reduces procurement and storing complexity
More informationMiniature Circuit-Breaker IEC Series 8562
> 1 to 3 pole versions > Rated current from 0.5... 40 A > 6 or 10 ka breaking capacity to DI VDE 0641, respectively E 60898 > Isolating Function to E 60947-2 > Permanently set thermal and magnetic trips
More informationSlot Resistance Thermometers
Slot Resistance Thermometers www.ephy-mess.de Contents 1. Slot Resistance Thermometer (NWT) 2 bifilar and chip type design 1.1 EPHY-MESS NWT delivery program list 2 1.2 Slot resistance thermometer with
More informationATX MRE Series 16 and 32 Amp Multiple Socket Outlets Stationary and Portable. Increased Safety
Applications Plugs and sockets are used with portable or stationary electrical equipment such as: Lighting systems Conveyors Heaters Motor generators Air conditioning equipment Compressors Pumps For use
More informationSeries 3731 TROVIS SAFE Electropneumatic Ex d Positioner
Series 3731 TROVIS SAFE 3731-3 Electropneumatic Ex d Positioner with HART communication Application Single-acting or double-acting Ex d positioner for attachment to pneumatic on/off valves in safety-instrumented
More informationOperating and monitoring systems Panel PC SERIES 400 Device platform EAGLE PM MT-436-TX
Panel PC for panel- mounting, quad core ATOM E3845 15" display, 1024 x 768 pixels with resistive foil touch screen 8 function keys Zone 2, 22 und Division 2, can be installed in hazardous areas without
More informationControl Buttons / Switches for Panel Mounting Series 8003
www.stahl.de > Different actuators pushbutton mushroom pushbutton mushroom stay-put button mushroom stay-put button with key lock key-operated button key-operated switch selector switch > 2 contact elements
More informationPneumatic Control/Feedback
897 /Feedback Type 897 can be combined with... Compact design Integrated pilot valve with manual override Internal control air routing Bright LED position indicator Automatic end position adjustment Type
More informationLoad Disconnect Switches and Motor Switches
Load Disconnect Switches and Motor Switches 594 Load Disconnect Switches and Motor Switches Contents Load Disconnect Switches and Motor Switches Safety Switches made of Resin 10, 12/16, 16, 20, 25, 40,
More informationMaterial Seat seal. N/en
0 / poppet valves electromagnetic actuated, directly controlled G /, / NPT or flanged with NAMUR interface TÜV-approval based on IEC 6 8 Valves for safety systems up to SIL Standard NAMUR type - redundancy:
More informationDigital EPIC Control Transmitters Weatherproof, Intrinsically Safe - ATEX/IEC
Weatherproof, Intrinsically Safe - ATEX/IEC Discrete position control and precision, non-contact position feedback with digital communication via HART protocol in a simple, integrated package. With options
More informationCable Glands 757, BVE and 737 Series: Blanking Plugs, Adaptors and Reducers Increased Safety and Flameproof
757 Series Blanking Plugs 737 Series Adaptors and Reducers BVE Series Plastic Blanking Plugs & Sealing Washers Compliance Data: 757 Series Blanking Plugs: ATEX IECEx CE Ex d IIC or Ex e II Ex td A21 IP
More informationCable End Boxes Series 8146
> Enclosures glass fibre reforced polyester res > For termals from 35... 185 mm 2 > Rated operational current up to max. 400 A dependg on enclosure version and size > Degree of protection IP55 www.stahl.de
More informationMinimum cross sectional area of Conductor mm²
Selection Overview Hawke International connectors are ideal for use in hazardous areas commonly found in Oil and Gas exploration, production and process plants. Their features, however, also offer numerous
More informationPage 1 of 5. Increased Safety, Encapsulation and Dust
IEC INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www iecex com Certificate No.: Status: Date of Issue: IECEx
More informationIECEx Certificate of Conformity
INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Certificate No.: IECEx LCI 10.0010X issue No.:1
More informationAssembly MAU. MUX 4 Channels 8 Channels Zone 1
Multi-Input/Output Device for Cabinet Installation Features Assembly For discrete inputs and outputs Installation in Zone 1/Div. 1, intrinsically safe Sensors in Zone 0/Div. 1 Connection to fieldbus acc.
More informationSeries Panel Mounted Control Devices
E_Master2012.qxd:NEW_E_Master_temp.qxd 1/27/12 4:28 PM Page 1 Series Features: Suitable for hazardous and corrosive locations. Installation is easy and precise. Devices fit into a standard 30.5mm, 1.2"
More informationSEM310 SEM310X HART UNIVERSAL TEMPERATURE TRANSMITTER
HART 5,6,7 COMPATABLE UNIVERSAL INPUT, DUAL CHANNEL ATEX & IEC Ex Version MATHS FUNCTIONS FLASH TESTED TO 4 KV DC INTRODUCTION The SEM310 is a HART 5 upwards, (generic device) compatible universal transmitter.
More informationDigital Output Module 4-Channel Version for Zone 1 Series 9475/
www.stahl.de > 4-channel digital output > Intrinsically safe outputs Ex ib > Suitable for Ex i hydraulic valves and solenoid valves > Additional Ex i control input for (in accordance with IEC 61508 through
More informationEx magnetic safety sensors, cylindrical form // Series EEx RC Si M30
Ex magnetic safety sensors, cylindrical form // Series EEx RC Si M30 - Ex zone 1 and 2, as well as 21 and 22 - Metal enclosure - Available in stainless steel enclosure - Reed contacts, coded - Actuation
More informationSeries 3730 Type Electropneumatic Positioner with PROFIBUS-PA communication
Series 3730 Type 3730-4 Electropneumatic Positioner with PROFIBUS-PA communication Application Positioners for attachment to pneumatic control valves Valve travel from 3.6 to 300 mm Opening angle 24 to
More information