OceanStor V3 Converged Storage Pre-sales Training HCS Storage Pre-sales Training
|
|
- Angelica McCarthy
- 5 years ago
- Views:
Transcription
1 OceanStor V3 Converged Storage Pre-sales Training HCS Storage Pre-sales Training
2 Page 2 Teacher name Background Project Experience Teacher name position teachername@huawei.com Specialist Skills
3 Contents 1 2 Positioning Hardware and software architectures 3 Price structure and License mode 4 Competitive analysis 3
4 Huawei Unified Storage Overview Entry-Level Block Unified storage S2200T S2600T 5300 V3 Mid-range Unified storage 5800 V V V V3 High End Series Vendor Huawei S2000T/2000 V V3/6000 V / V3 EMC VNXe VNX VMAX HDS SMS100 HUS/ASM2000 USP/VSP IBM DS3000 V7000/DS5000 DS8000 HP P2000 3par StorServ 7000 NetApp FAS2000 FAS8000 P10000 Entry-level Mid-range High-end 4
5 Challenge: Application explosion vs. storage islands Application Traditional Apps Storage Cloud Apps Source: IDC, Gartner
6 OceanStor V3 Enterprise converged storage SSD&HDD Convergence SAN&NAS Convergence High-end, mid-range, entry level Convergence Primary & Backup Storage Convergence Heterogeneous storage Convergence OceanStor V3 Unified & easy management State-of-the-art hardware 6
7 Convergence of SAN and NAS Traditional storage OceanStor V3 series SAN NAS Or NAS SAN NAS + SAN Two storage devices are required to provide SAN and NAS services. The efficiency of databases and file sharing services cannot be maximized. Block- and file-level data storage is unified, requiring no additional file engines, simplifying deployment, and reducing purchase cost. The efficiency of databases and file sharing services is notably improved. 7
8 Convergence of high-end, mid-range, and entry-level storage systems Traditional storage OceanStor V3 series Highend Highend Entrylevel Midrange Entrylevel Midrange Diverse architectures Different operation habits No data flow High-end, mid-range, and entry-level storage systems interwork, enabling free data flow. High-end, mid-range, and entry-level storage systems are managed in a unified manner, multiple times the efficiency. 8
9 Convergence of heterogeneous storage Traditional storage OceanStor V3 series Heterogeneous devices and diverse operating systems Storage systems from different vendors have diverse models and run different operating systems. Complex management and low efficiency Legacy storage systems are reused, protecting the original investment. Pools of third-party storage resources simplify storage management and achieve cloud-based storage. 9
10 Convergence of SSDs and HDDs Traditional storage OceanStor V3 series HDD storage system SSD storage system HDD SSD HDD pool SSD pool To choose large-capacity and costeffective traditional HDD storage systems or to choose highperformance SSD storage systems? This is a question. All-flash arrays are optimized to put the high performance and low latency advantages of SSDs into full play. HDDs and SSDs are converged to meet the performance requirements of complex services. 10
11 Converged backup Traditional storage OceanStor V3 series Backup software on the server Primary storage Backup storage Backup server + backup software + backup storage High cost and complex network Backup storage is perfectly integrated into primary storage, requiring no additional backup software and reducing your purchase cost. Primary storage and backup storage are managed in a unified manner, simplifying the O&M of backup solutions. 11
12 Huawei storage product positioning and SDS evolving Performance Oracle Hadoop OpenStack < 100 us 1 ms 10 ms 100 ms >1s Real Time Storage OceanStor V3 Unified Storage Big Data Storage Cold Storage SDS controller <1 TB 100 TB 1 PB 100 PB >1 EB Capacity
13 Use case positioning Production data center Remote DR data center DB Apps Emai l OA VM Backup server Apps FC FC/FCoE NFS/CIFS/iSCSI Unified Storage Unified Storage V3 Use Cases Consolidation OLTP Server virtualization and VDI Private cloud Backup DR 13 13
14 Contents 1 2 Positioning Hardware and software architectures 3 Price structure and License mode 4 Competitive analysis 14
15 HUAWEI OceanStor V3 series storage systems 5300 V V V V V3 Unified software/hardware/management platform 15
16 OceanStor V3 series specifications Product Name 5300 V V V V V3 Hardware specifications Controller enclosure form 2 U disk and controller integration 2 U disk and controller integration 3 U independent engine 3 U independent engine 6 U independent engine Supported disk quantity Max. number of controllers Cache capacity (dual-controller) Max. number of front-end host ports (dual-controller) Software specifications 32 GB / 64 GB (planned) 48 GB / 96 GB / 128 GB (planned) 64 GB / 128 GB 128 GB / 256 GB 256 GB / 512 GB/1024GB Base software File Block Basic software license for block (including Device Management, SmartThin, SmartMulti-tenant, SmartMigration, SmartErase, Cloud Service) Upgrade license from block to unified storage (including SmartDedupe & SmartCompression (for FS), SmartQuota, NFS, CIFS, NDMP) CIFS NFS NDMP license SmartQuota (intelligent quota) HyperLock (WORM) HyperSnap (snapshot) HyperReplication (remote replication) SmartCache (intelligent SSD caching), SmartQoS (intelligent service quality control) SmartPartition (intelligent cache partitioning), SmartDedupe & SmartCompression (intelligent data deduplication and compression HyperCopy (LUN copy) HyperClone (cloning) HyperMirror (volume mirroring) HyperSnap (snapshot) HyperReplication (remote replication) SmartCache (intelligent SSD caching), SmartQoS (intelligent service quality control) SmartPartition (intelligent cache partitioning), SmartDedupe & SmartCompression (intelligent data deduplication and compression) SmartTier (intelligent data tiering), SystemReporter (system report software) SmartVirtualization (intelligent heterogeneous virtualization), SmartMotion (intelligent data migration) 16
17 Specifications Replacement of T series OceanStor High-end storage product S5800T 192 GB S6800T 192 GB/384 GB 6800 V3 128GB/256 GB/512 GB 128 GB to 256 GB of cache becomes a standard of the mid-range and high-end storage systems. S5800T/S6800T V2 are highly competitive. S5600T 24 GB/48 GB In fierce competition of mid-range storage system market, the competence of the S5600T decreases, whereas the S5800T becomes increasingly competitive. S2600T 16 GB S5800T 96 GB Mid-range and entry-level S2600T and S5500T stay competitive in a long term. S5500T 16 Gb/32 GB 5600 V3 64 GB/128 GB 5300 V3 64 GB 5300 V3 32 GB Add 5300 V3 to expand the coverage of mid-range and entry-level storage systems. Add 5600 V3/5800 V3 to comprehensively increase the competitiveness and coverage of Huawei mid-range and high-end storage systems. Use 5600 V3 as a mid-range storage system to increase S5800T V2's competence if necessary V3 48 GB/96 GB Add 5500 V3 to strength Huawei's presence in the mid-range market and increase the S5600T's competence. Product version 17
18 Product architecture iscsi/fc/fcoe NFS/CIFS/FTP/HTTP File+ Block Capacity Controllers Disk Enclosure Block service File service LUN Semantics File Semantics Storage pool RAID 2.0+ Management Hardware 18
19 Unified storage platform Model 5300 V V V V V3 2 U platform 3 U platform 6 U platform Controller Platform (SAN + NAS) Disk Enclosure Platform 2 U 25 x 2.5-inch disk enclosure 4 U 24 x 3.5-inch disk enclosure 4 U 75 x 3.5-inch high-density disk enclosure 19
20 5300 V3/5500 V3 controller Power-BBU-Fan modules 1+1 Up to 94% of power conversion efficiency 48 V DC and 240 V DC 110/220 V AC Onboard ports 20 SAS expansion ports Two SAS 3.0 expansion ports per controller 5300 V3: four GE ports per controller 5500 V3: four 8 Gbit/s Fibre Channel ports per controller Interface modules Two slots for hot-swappable interface modules Port types: 8 or 16 Gbit/s Fibre Channel, GE, 10GE TOE, 10GE FCoE, and 12 Gbit/s SAS
21 5600 V3/5800 V3 controller BBU modules 5600 V3: 1+1; 5800 V3: 2+1 AC power failure protection Controller modules Dual controllers Automatic frequency adjustment for reduced power consumption Built-in fan modules (fan modules are integrated in controller modules, but can be maintained independently) Management modules 1+1 Hot-swappable Multi-controller scale-out and interconnection for establishing heartbeats Power modules 1+1 Up to 94% of power conversion efficiency 240 V DC Interface modules 16 slots for hot-swappable interface modules Port types: 8 or 16 Gbit/s Fibre Channel, GE, 10GE TOE, 10GE FCoE, and 12 Gbit/s SAS 21
22 5600 V3/5800 V3 Controller BBU module Interface module System enclosure Management module Power module Controller 22
23 6800 V3 controller BBU modules 3+1 AC power failure protection Controller modules 2- or 4-controller configuration Automatic frequency adjustment for reduced power consumption Built-in fan modules (fan modules are integrated in controller modules, but can be maintained independently) Power modules V DC Up to 94% of power conversion efficiency Management modules 1+1 Hot-swappable Multi-controller scale-out and interconnection for establishing heartbeats Interface modules 2-controller: 12; 4-controller: 24 Hot-swappable Port types: 8 or 16 Gbit/s Fibre Channel, GE, 10GE TOE, 10GE FCoE, and 12 Gbit/s SAS 23
24 6800 V3 Controller Interface module BBU module Management module System enclosure Power module Controller 24
25 Disk enclosure platform 2 U disk enclosure: 25 x 2.5-inch disks Disk module Power module Expansion module 4 U disk enclosure: 24 x 3.5-inch disks Disk module Fan module Expansion module Power module 25
26 High-density disk enclosure Power module System enclosure Fan module Disk module Expansion module 4 U high-density disk enclosure: 75 x 3.5-inch disks 26
27 SmartI/O card F C ETH 5 Unified Multiprotocol adapter 8 Gbit/s and 16 Gbit/s FC 10 Gbit/s FCoE 10 Gbit/s iwarp (Scale-out) Port mode switchover on the management (FC/ETH/Scale-out) Use corresponding optical modules after a port mode switchover. 1 Module Power indicator/hot Swap button 2 16 Gbit/s FC/8 Gbit/s FC/10GE port 3 Link/Active/Mode indicator of the port 4 Module handle 5 Module mode silkscreen 27
28 Deduplication/compression acceleration card (ACC) Module Power indicator/hot Swap button 2 Active indicator 3 Module handler/silkscreen Functions: Provides a variety of functions such as deduplication fingerprint computing, GZIP compression and decompression, and hardware acceleration, and relieves CPU workloads, improving system deduplication and compression performance. No. Indicator Description 1 Module Power indicator Steady green: The module is working correctly. Blinking green: The module receives a hot swap request. Steady red: The module malfunctions. Off: The module is powered off or hot swappable. 2 Active indicator of the port Steady green: No data is being processed. Blinking green: Data is being processed. Off: The module is not working correctly. 28
29 IP Scale-out (2 U) Back-end ports Front-end service ports Scale-out ports A SmartI/O card must be used to implement Scaleout and must be inserted into fixed slot 1. A V V3 B1 30
30 IP Scale-out (2 U four-controller direct-connection) Management port: You are advised to connect to a network using management ports of controller 0 first. The number of management ports required is based on site requirements. A direct-connection network supports a maximum of four controllers. 31
31 IP Scale-out (2 U four-controller switch-connection) ETH management ports on the rear panel of a CE6850 switch can be used to connect a user's network. CE6850 switch 1 CE6850 switch 2 A switch-connection network supports a maximum of eight controllers. A direct-connection network cannot be switched to a switch-connection network. 2 U controller enclosure 1 2 U controller enclosure 2 32
32 IP Scale-out (3 U) Back-end ports Front-end service ports Scale-out ports A SmartI/O card must be used to implement Scaleout and must be inserted into fixed slot V V3 A3 B3 33
33 IP Scale-out (3 U four-controller direct-connection) A direct-connection network supports a maximum of four controllers. 34
34 IP Scale-out (3 U eight-controller switch-connection) CE6850 switch 1 CE6850 switch 2 A switch-connection network supports a maximum of eight controllers. 3 U controller enclosure 1 A direct-connection network cannot be switched to a switch-connection network. 3 U controller enclosure 2 3 U controller enclosure 3 3 U controller enclosure 4 35
35 IP Scale-out (6 U) Back-end ports Front-end service ports 6800 V3 A3 Fixed Scale-out slots B3 A SmartI/O card must be used to implement Scale-out and must be inserted into fixed slot 3. 36
36 IP Scale-out (6 U six-controller switch-connection) CE6850 switch 1 A switch-connection network supports a maximum of eight controllers. CE6850 switch 2 6 U controller enclosure 1 6 U controllers do not support direct-connection networks. 6 U controller enclosure 2 37
37 IP Scale-out (6 U eight-controller switch-connection) CE6850 switch 1 A switch-connection network supports a maximum of eight controllers. CE6850 switch 2 6 U controller enclosure 1 6 U controllers do not support direct-connection networks. 6 U controller enclosure 2 38
38 39
39 RAID 2.0+: Basis of OceanStor OS RAID 2.0+: Block-level aggregation LUN Virtual pool Physical HDD Benefits: 1. Wide stripe of the data, accelerating performance 2. Many-to-many disks rebuild, 20x speed, higher reliability Traditional RAID Hot spare LUN Physical HDD 40
40 RAID2.0+ block virtualization technology SSD Physical disk Pool Chunk CKG Extent Volume LUN Tiered SAS NLSAS Nontiered Different types of disks are distributed in the pool Break each disk into finegrain Chunk(64MB) Chunks from different disks shape the chunk group(ckg) CKG is broken into smaller space(256kb~ 64MB) Nontiered Several Extent shape Volume LUN can be constructed in a short time. There is no need to allocate the resource in advance, 41
41 RAID2.0+ Benefit -- Wide stripe LUN block-level virtualization,lun is not limited within a RAID group, but could span all disks in the system Pool 42
42 RAID2.0+ Benefit -- Decoupling application and physical storage resource Extent1 Host Creates tiers in the pool, each having a different disk type. Pool CKG Within the monitoring period, records the read CKG Tier0 SSD Tier1 SAS Extent2 Extent3 LUN Extent1 Extent2 Extent3 Extent4 and write I/O frequency in a unit of extent (512 KB to 64 MB). Within the migration period, migrates extents between tiers according to the frequency analysis result. Extent4 The migration does not interrupt host I/Os. CKG Tier2 NL SAS 43
43 RAID2.0+ Benefit -- Many-to-many Fast Rebuild Traditional RAID RAID2.0+ Supported RAID type RAID0, RAID5,RAID6,RAID10 Few-to-One Rebuild Hot Spare disk hotspots & long rebuild exposure Unallocated CK Hot Spare space Many-to-Many Rebuild parallel rebuilds in less time 30mins rebuild 1TB data 44
44 Data Layout Comparison Hot spare Hot spare Traditional RAID LUN virtualization EMC: VNX Block virtualization Huawei: RAID 2.0+ HP 3PAR: Fast RAID IBM XIV: Super stripe 45
45 OceanStor V3 software overview OceanStor OS Simple management Data acceleration Data protection Intelligent and high-end features (QoS and cache partitioning) of Smart series software accelerate critical service responses. The integration of SAN and NAS enables storage resources to be intelligently allocated on demand. O&M management Hyper series security features provide comprehensive data protection for local, remote, and other sites, effectively ensuring high data reliability and security. Easy-to-configure management software helps users operate and maintain multi-brand and cross-field devices in a unified manner and provides GUI-based end-to-end management, significantly promoting the BYOD management efficiency. Smart series software suite Comprehensive high-end features, bringing optimal user experience SAN and NAS integration, enabling ondemand resource allocation Hyper series data protection suite Multi-dimensional data protection and diverse 3DC DR solutions for high reliability and security Simple management software suite Simple management from single devices to multi-brand and cross-field devices, suitable for BYOD environments 46
46 Two-level Management esight Unified Management Server Network DeviceManager Storage 47
47 esight -- Storage Resource Management Software esight Topology display Status management Fault alarm Device discovery Storage path Capacity and performance Trend Report Remote maintenance Application Host Network Storage Fiber Channel/IP Switch 48
48 DeviceManager Storage Device Management B/S WEB Interface Design for IT generalist, easy to use Alarm monitoring Capacity allocation Performance display 49
49 Industry standard platform Management Industry ISV esdk -- Ecosystem Application VMware vcenter Microsoft System Center Symantec VOM OpenStack CA HP OpenView IBM Tivoli Media & entertainment energy Financial Nagios EMC SRM Suite Education Plug-in Management SDK Plug-in Provider vcenter Plug-In Cinder Plug-In SMI-S Provider System Center Plug- In Nagios Plug-In VASA Provider esdk OpenAPI Restful API SNMP host configura tion capacit y alarm perfor mance Data protection Pool LUN protocol FS Quota Resource optimizati Multitenanc DR on y Block service backup Storage product SAN, NAS Cloud storage 50
50 V3 add-on Features Block based Efficiency software suite Data protection software suite SmartVirtualization Data movement across systems SmartMotion Horizontal data movement SmartQoS Intelligent service quality control HyperSnap: protects local data based on increments. HyperClone: protects local data based on full copies. HW EMC HDS IBM SmartThin Thin provisioning HyperCopy: protects data between devices. HyperReplication: implements DR protection between data centers. SmartTier Vertical data movement SmartPartition Intelligent cache partitioning Partition 1 SmartDedupe & SmartCompression Intelligent data deduplication and compression APP APP APP Partition 2 Partition 3 Partition 4 Partition 5 Partition N SmartCache Intelligent SSD caching SmartErase Data destruction SmartMigration LUN relocation SmartMulti-Tenant Multi-tenant 51
51 HyperSnap (virtual snapshot) x y Nonsnapshot point in time HyperSnap working principle 1. Before HyperSnap is enabled, the way that data is written remains unchanged. 2. After HyperSnap is enabled, a mapping table is created to record data mapping relationships. 3. Copy-on write (COW) is performed. Before new data is written, data in the original data block of the source LUN is written to the resource space and the mapping table is modified accordingly. 4. The data in the original data block is overwritten when new data is added to the data block. 5. The snapshot is rolled back. a d Data at Snapshot the point in b snapshot time point in c time d e f g Source LUN Mapping table Resource space 52 Concept As one of snapshot technologies (including LUN clone), a virtual snapshot is a point-in-time copy of source data. The implementation of a virtual snapshot depends on its source LUN. Technical highlights Quick snapshot generation: A storage system can generate a snapshot within several seconds. Low storage space consumption: Snapshots are not full physical copies of source data. Therefore, only a small amount of storage space is required. Application scenarios Rapid data backup and restore for addressing mistaken data deletion and viruses. Continuous data protection Data analysis and tests
52 Split HyperClone (LUN clone) HyperClone working principle For the same data blocks, the bitmaps are marked as "0" while for different data blocks, the bitmaps are marked as "1". a b c dj e f g h i Primary LUN mn jk l Progress bitmap Initial synchronization Bitmaps that have been copied are marked as "0" while bitmaps that are being copied or to be copied are marked as "1". a b c Secondary LUN Concept Clone, a type of snapshot technology, obtains fully populated point-in-time copies of source data. Clone is a backup approach that allows incremental synchronization. HyperClone working principle 1. If the primary LUN receives a write request from the production host during the initial synchronization, the storage system checks the synchronization progress. 2. If the original data block to be replaced is not synchronized to the secondary LUN, the new data block is written to the primary LUN and the storage system returns a write success acknowledgement to the host. Then, the synchronization task will synchronize the new data block to the secondary LUN. 3. If the original data block to be replaced has already been synchronized, the new data block must be written to the primary and secondary LUNs. 4. If the original data block to be replaced is being synchronized, the storage system waits until the data block is copied. Then, the storage system writes the new data block to the primary and secondary LUNs. 5. After the initial synchronization is complete, the primary LUN is split from the secondary one. Then, both the primary and secondary LUNs can be used separately for testing and data analysis. Data changes made to the primary and secondary LUNs do not affect each other, and the progress bitmap records data changes on both LUNs. Highlights and application scenarios If the primary LUN is damaged, its secondary LUNs are not affected. The primary LUN can have multiple secondary LUNs. HyperClone is applicable to data backup, protection, analysis, and tests. 53
53 HyperCopy (LUN copy) HyperCopy working principle Service suspension Source LUN Full LUN copy LUN copy 54 Target LUN Concept HyperCopy copies data from a source LUN to a target LUN within one storage system and between storage systems. HyperCopy working principle Full LUN copy copies all data from the source LUN to the target LUN. Full LUN copy is performed offline. If the source LUN receives a write I/Os during data copy, the data on the target LUN becomes inconsistent with data on the source LUN. Therefore, write I/Os on the source LUN need to be stopped during replication. Highlights and application scenarios Support for third-party storage Applicable to scenarios where the capacity of a source LUN is smaller than that of a target LUN Data migration within one storage system and between storage systems Data backup
54 HyperReplication/S (synchronous remote replication) HyperReplication/S working principle Cache Cache Synchronous remote replication LUN A LUN B Primary site 55 Secondary site Highlights and application scenarios Zero data loss 32:1 replication ration (sum of synchronous remote replication and asynchronous remote replication) Mutual mirroring relationship between primary and secondary storage Applicable to local or intra-city data DR Concept The secondary site synchronizes data with the primary site in real time to achieve full protection for data consistency and minimize data loss in the event of a disaster. HyperReplication/S working principle When a synchronous remote replication task is established, an initial synchronization is performed to replicate all the data from the primary LUN to the secondary LUN. After the initial synchronization is complete and the primary LUN receives a write request from the production host, I/Os will be processed according to the following processes: 1. The primary LUN receives a write request from a production host and sets the differential log value to differential for the data block corresponding to the I/O. 2. The primary site writes the data of the request to the primary LUN (LUN A) and sends the write request to the secondary site through the configured replication link. 3. If data is successfully written to both LUN A and LUN B, the corresponding differential log value is changed to non-differential. Otherwise, the value remains differential, and the data block will be copied again in the next synchronization. 4. The primary site sends a write success acknowledgement to the host.
55 HyperReplication/A (asynchronous remote replication) HyperReplication/A working principle 2 3 N+1 N Cache 5 LUN A 1 Asynchronous remote replication 56 Cache LUN B Primary site Secondary site Innovative multi-time-segment caching technology (patent number: PCT/CN2013/080203) for second-level RPO 4 X+1 Highlights and application scenarios Little impact on performance and RPO reduced to 5 seconds 32:1 replication ration (sum of synchronous remote replication and asynchronous remote replication) Mutual mirroring relationship between primary and secondary storage Applicable to local, intra-city, and remote data DR X 5 1 Concept Data is synchronized periodically to minimize the adverse impact on service performance caused by the long latency of long-distance data transfer. HyperReplication/A working principle When an asynchronous remote replication task is established, an initial synchronization is performed to copy all data from the primary LUN to the secondary LUN. After the initial synchronization is complete, I/Os will be processed according to the following processes: 1. When a replication period starts, data parts with new time segments (TPN+1 and TPX+1) are respectively generated in the caches of the primary LUN (LUN A) and the secondary LUN (LUN B). 2. The primary site receives a write request from a production host. 3. The primary site writes the requested data to the part with the TPN+1 time segment and sends an acknowledgement to the host. 4. During data synchronization, the storage system reads data in cache time segment TPN of the primary LUN in the previous synchronization period, transmits the data to the secondary site, and writes the data to cache time segment TPX+1 of the secondary LUN. When the write cache of the primary site reaches the high watermark, data in the cache is automatically flushed to disks. In this case, a snapshot is generated for data of time segment TPN. 5. During synchronization, such data is read from the snapshot and copied to the secondary LUN.
56 HyperMirror (volume mirroring) Concept Mirror copy A Ordinary LUN Mirror LUN Mirror copy B HyperMirror is a data backup technology. It creates multiple physical mirror copies for a LUN to achieve continuous LUN backup and protection. In this way, the reliability and availability of the LUN are significantly improved. Working principle Mirror LUNs are presented as ordinary LUNs. Mirror copies of a mirror LUN can be from local or third-party LUNs. Write I/Os access both mirror copies A and B, while, read I/Os access only one of the mirror copies. A mirror copy can be split and used for data recovery. Data between mirror copies must be consistent. Highlights If a third-party LUN fails to be accessed due to a third-party array failure, LUN services will not be interrupted. If a LUN fails because a local RAID 5 dual-disk (RAID 6 triple-disk) fails, services will not be interrupted. Data changes will be automatically copied to the LUN after the fault is rectified. After a mirror LUN is used for local HA, value-added features such as snapshot, replication, clone, or copy can be configured for the mirror LUN. Volume mirrors can be used to improve LUN read performance. 57
57 HyperMirror application scenarios Host Mirror copy Mirror LUN Mirror copy Scenario 1: Intra-array volume mirrors can be used to improve LUN reliability. LUNs in mirror groups belong to different disk domains. Host LUN Third-party storage array Mirror copy Mirror LUN Mirror copy Huawei storage array LUN of a thirdparty storage array LUN of a Huawei storage array Scenario 2: Working with SmartVirtualization, volume mirrors of a third-party array can be used to improve third-party array reliability. Host LUN Mirror LUN Mirror copy Mirror copy Huawei storage array LUN LUN of a thirdparty storage array LUN of a Huawei storage array Scenario 3: Working with SmartVirtualization, volume mirrors of two third-party arrays can be used to improve third-party array reliability and reuse efficiency. Third-party storage array Third-party storage array 58
58 Competitive analysis of HyperMirror In the mainstream mid-range storage systems, only IBM V7000 has the volume mirroring function. The volume mirroring function is not available in any mainstream high-end storage systems, but is provided in gateway products. Competition Item EMC VPLEX IBM V7000/SVC Huawei HyperMirror Product type Virtual gateway V7000: array SVC: virtual gateway Array Third party array supported Yes Yes Yes Round-robin read supported Yes No Yes Replication services No configured for mirror LUNs RecoveryPoint required Yes Yes Value-added features inherited after conversions between non-mirrors and N/A Yes No mirrors Number of branches Data recovery mode Incremental Incremental Incremental Cache Read and write cache Read and write cache Read and write cache 59
59 SmartVirtualization (intelligent heterogeneous virtualization) Concept edevlun External LUN: A LUN in a third-party storage system. Metadata volume Data volume LUN (external LUN) edevlun: On the local storage system, a third-party LUN is virtualized into an edevlun. A user can map an edevlun to an application server or configure value-added services for an edevlun as an ordinary LUN. An edevlun resides in a storage pool of the local storage system. Application server Local storage system Third-party storage system Data organization The local storage system adopts block-level virtualization storage technology to manage space. An edevlun consists the following two parts: Meta volume: Such a volume records the data organization form and data attributes. A meta volume adopts a tree structure. The local storage system provides storage space for meta volumes. Data volume: Such a volume stores actual user data. External LUNs of a third-party storage system provide storage space for data volumes. Application scenarios Consolidation of heterogeneous storage systems and full reuse of legacy storage systems EMC IBM 60 HUAWEI Heterogeneous data migration with LUN migration features Heterogeneous data protection with snapshot, clone, replication
60 SmartMulti-Tenant (multi-tenant) Storage administrator Tenant A Data Data Data Tenant administrator A Tenant B Data Data Data Tenant administrator B 61 Tenant C Data Data Data Tenant administrator C A storage administrator manages all resources in a storage array and all tenants. A tenant administrator can only manage resources in its tenant. SmartMulti-Tenant efficiently separates the resource data of tenants and assigns the management work of some resources to tenants to make tenants manage resources in their own domains. Working principle Rights- and domain-based management: Tenant administrators can manage LUNs and monitor LUN performance. The storage administrator can allocate LUNs to tenants, and assign and manage tenant administrators. Resource management The storage administrator has full resource management permission, whereas tenant administrators can only query resources. Application scenarios Hosting environment isolation of telecom service providers' billing, CRM, and payment systems, dealer portals, and application programs Data isolation of large enterprises' HR records, and financial and customer information Data isolation of government departments' taxation, welfare, education, national defense records
61 SmartErase (data destruction) Provides two data destruction methods to prevent sensitive data leakage. DoD: provides a software method of destroying data on writable storage media, namely, three times of overwriting. 1. Using an 8-bit character to overwrite all addresses 2. Using the complementary codes of the character (complements of 0 and 1) to overwrite all addresses 3. Using a random character to overwrite all addresses Customized: A system generates data based on internal algorithms and uses the data to overwrite all addresses of LUNs for specific times. The times of overwriting range from 3 to 99. The default value is 7. 62
62 SmartTier (intelligent data tiering) Data monitoring Distribution analysis The I/O monitoring module counts the activity levels of all data blocks. The data distribution analysis module ranks the activity level of each data block. Highlights SmartTier meets the requirements of enterprises on both performance and capacity. By preventing historical data from occupying expensive storage media, it ensures effective investment and eliminates energy consumption caused by useless capacities, reducing TCO and optimizing cost effectiveness. Data migration The data migration module migrates data based on the ranking and data migration policy. Indicator With SmartTier Without SmartTier Configurations 12 x 200 GB SSDs 36 x 300 GB 10k rpm SAS 132 x 300 GB 10k rpm SAS disks Migration mode Manual and automatic migration modes are available. I/O monitoring and migration periods can be configured. Number of 2 U disk enclosures Tier 0 application I/O latency ms 10 ms Migration speed The migration speed can be high, medium, or low. Migration policy Four migration policies are available: Automatic migration, Migration to a higher performance tier, Migration to a lower performance tier, and No migration. Tier 1 application I/O latency Storage space utilization rate 7 ms 20 ms 70% 20% Power 500 w 1500 w The IOPS of the virtual hybrid load mode (18 Exchange VMs, 2 database VMs, and 2 application VMs) is up to 26,
63 64
64 Ondemand allocation SmartThin (intelligent thin provisioning) 1. Send write requests. Thin LUN 8 KB 8 KB 8 KB 8 KB 8 KB 8 KB Data volume: 32 KB Allocated space: 256 KB 8 KB 8 KB Actual storage data 2. Query the mapping table for modification or data allocation. Space allocation Data volume: 32 KB Allocated space: 128 MB 65 Physical space Pool 32 MB 32 MB 32 MB 32 MB Working principle Capacity-on-write: When allocated space becomes insufficient, storage space is added in a unit of 64 KB by default. Mapping table: Logical units and physical units (default granularity of 64 KB) are associated using a mapping table. Direct-on-time: I/Os of read and write logical units are redirected to physical units using a mapping table. Highlights Efficient allocation policies: allocate resources at a granularity of 64 KB, ensuring great efficiency for scenarios with small data blocks. Various reclamation mechanisms: support VMware VAAI, Symantec Storage Foundation, and Windows Server 2012 command reclamation, and all-zero page reclamation. Application scenarios SmartThin can help core service systems that have demanding requirements on business continuity, such as bank transaction systems, to expand system capacity online without interrupting ongoing services. Services where the growth of application system data is hard to be accurately evaluated, such as services and web disk services. SmartThin can assist with on-demand physical space allocation, preventing a space waste. Mixed services that have diverse storage requirements, such as carriers' services. SmartThin can assist with physical space contention, achieving optimized space configuration.
65 SmartQoS (intelligent service quality control) To ensure the performance of mission-critical Enable priority-based control. Critical service (high) Key service (medium) Generable service (low) services, SmartQoS sets a performance goal for each service, applicable to scenarios with mixed Single service performance services. Priority-based policy: Multiple I/O queues are maintained in the storage system. Based on I/O Performance of general services increases, affecting that of critical services. Enable the flow control policy. Overall performance queue priorities, I/O queues are managed by controlling of front-end concurrences, CPU, cache, and back-end disks. Limit the performance of general services to prevent impact on others. General service Critical service Flow control mechanism: Non-critical applications are prevented from consuming too many storage resources by the limiting of their IOPS, bandwidth, and latency. 66
66 SmartQoS (intelligent service quality control) Enable performance assurance. Overall performance Target: 8000 Critical service (high) Performance reaches the expected level. (5000 to 8000) Key service (medium) Performance drops 20%. General service (low) Performance drops 40%. Flow control mechanism: Minimum performance indicators such as IOPS, bandwidth, and latency are set for critical applications. In this way, the storage system ensures these indicators regardless of storage workload changes. 67
67 SmartPartition (intelligent cache partitioning) SmartPartition SmartPartition ensures the performance of critical applications by partitioning core system resources. Host concurrency Cache Disk access concurrency Service 1 Service 2 Service 3 Service 4 Working principle Divides storage resources into cache partitions with various sizes. Allocates different applications to different cache partitions. The storage system automatically adjusts host and disk access concurrencies of each cache partition, ensuring service quality of applications. Highlights Dedicated cache partitions for service isolation, improving service reliability Dedicated assurance for core services and full utilization of cache resources, significantly improving service quality Applicable to application scenarios with mixed services 68
68 SmartCache LUN/File system Dedupe Meta RAM Cache SmartCache HDD SSD LUN SSD LUN Storage pool SmartCache SSD 69 SmartCache uses SSDs as read cache and works with RAM Cache to accelerate data read for LUNs and file systems. It also functions as read cache for deduplication metadata to improve storage system performance. Working principle Employs SmartCache pools to manage SSDs and supports online capacity expansion and reduction. Uses SmartCache partitions to manage allocated space and supports service isolation based on service priorities. Adopts cyclic sequential write to enhance write performance and prolong SSD service life. Leverages LUNs or file systems to add or delete SmartCache partitions, and flexibly enables or disables the SmartCache function of a LUN or file system. Application scenarios SmartCache applies to services that have hotspot areas and intensive small random read I/Os, for example, databases, OLTP applications, web services, and file services.
69 V3 add-on Features File based NAS service features CIFS NFS NDMP Common Internet File System Network File System Network Data Management Protocol SmartThin SmartQoS SmartPartition SmartCache Thin provisioning Intelligent service quality control Intelligent cache partitioning Intelligent SSD caching SmartDedupe SmartCompression SmartQuota Intelligent data deduplication Online compression Quota management HyperSnap HyperReplication HyperLock Snapshot Remote replication WORM 70
70 HyperSnap root snapshot To be deleted Used data1 data2 data3 data4 data5 data6 data7 data8 data9 1. Second-level generation When creating a snapshot for a file system, you only need to copy and store the root node of the file system. No user data is copied during the process. The snapshot generation can be complete in 1 or 2 seconds. Before data is modified, the snapshot file set and the primary file system share the same file system space, so no additional space is required by the snapshot file set. 2. Second-level deletion Deleting snapshots releases root node pointers and the data exclusively occupied by the snapshots, but file system data is not affected. Only exclusively occupied space is reclaimed and shared data will not be deleted. Snapshots of a unified file system can be deleted in seconds and space exclusively occupied by the snapshots is gradually reclaimed by background tasks
71 HyperReplication HyperReplication (for file systems) is a file system remote replication feature. It supports only asynchronous remote replication between file systems. Remote replication, one of core DR technologies, maintains data duplicates at two or more sites far from each other, thereby preventing disasters from causing data loss. Application scenarios: remote DR and centralized DR Production center DR center FS Service site 01 NFS/ CIFS NFS/ CIFS FS Service site 02 FC/ iscsi FS FS FS FC/ iscsi FS FS FS Central DR site 72
72 HyperLock WORM The process for creating a WORM file system is similar to that for creating a common file system. You need only to set the type to WORM and specify properties when creating a file system. Initial: All newly created files are in this state. In this state, files can be changed. Locked: A file in this state is being protected and cannot be modified, deleted, or renamed. Expired: Any user can delete a file in this state and can read data or view properties of the file. Any other operation request will fail. Added: Data can be added to the end of a file in this state. The file cannot be deleted or truncated. 73
73 SmartQuota SmartQuota (the quota management feature) manages and controls resources to limit the maximum resources (including capacity space and file quantity) allowed for a directory, preventing resources from being overly used by some users and ensuring normal resource utilization. A directory exclusively used by manager A limits resources available for manager A. NAS Manager A A directory used by project group A limits resources available for project group A. Shares Engineer A Engineer B... A directory used by the Sales Department limits resources available for the Sales Department. Sales person A Sales person B... Engineer A Engineer B... Sales person A Sales person B... Manager A... Typical configuration 1. SmartQuota can be enabled for a shared directory that is configured for a department, project group, or user to limit the maximum resources available for the directory. 2. Working with the ACL permission management, SmartQuota allows users with corresponding permissions to access directories. 3. SmartQuota determines resources available for each directory. 74
74 Contents 1 2 Positioning Hardware and software architectures 3 Price structure and License mode 4 Competitive analysis 75
75 Quotation elements for the V3 series Storage form SAN or SAN + NAS Controller enclosure Storage unit Controller enclosure specifications (AC, DC, and cache size) Disk unit (SAS/NL-SAS/SSD) Disk enclosure (ordinary or high-density) Auxiliary device Modem/Cabinet Value-added software Value-added storage software 76
76 Software License Base software File Block Software and Value-added Function Basic software license for block (including Device Management, SmartThin, SmartMulti-ten ant, SmartMigration, SmartErase, Cloud Service) Upgrade license from block to unified storage (including SmartDedupe & SmartCompression (for FS), SmartQuota, NFS, CIFS, NDMP) CIFS NFS NDMP license SmartQuota (intelligent quota) HyperLock (intelligent WORM) HyperSnap HyperReplication SmartCache, SmartQoS, SmartPartition HyperCopy (LUN copy) HyperClone (cloning) HyperMirror (volume mirroring) HyperSnap (snapshot) HyperReplication (remote replication) SmartCache (intelligent SSD caching), SmartQoS (intelligent service quality control), SmartPartition (intelligent cache partitioning), SmartDedupe & SmartCompression (intelligent data deduplication and compression) SmartTier (intelligent data tiering), SystemReporter (system report software), SmartVirtualization (intelligent heterogeneous virtualization), SmartMotion (intelligent data migration) OceanStor UltraPath license 77 Mandatory for SAN Description Configured during SAN storage upgrade to unified storage or SAN+NAS integrated storage Quotation of the file engine software is described as follows: 1. Select file functions. The items in red are included in the base software package. 2. Other NAS value-added functions are optional. Value-added functions (optional) Value-added functions (optional) Mandatory 5300 V3 is included in the base software package. Other models are quoted separately.
77 Contents 1 2 Positioning Hardware and software architectures 3 Price structure and License mode 4 Competitive analysis 78
78 Overall OceanStor V3 Series Competition Strategy Brand Architecture Storage Service New product, lack of application, weak brand Innovative architecture, high performance, capacity and scalability Five convergences Pricing Aiming EMC, 20% lower EMC VNX NetApp IBM StorWize HP StorServ Huawei OceanStor V3 Overall competition strategy: Focus on traditional enterprise application and private cloud environment. Beat IBM, HP, with technology. Beat EMC and NetApp with Price. 79
79 OceanStor V3 Series Advantage Highlights Multi-controller architecture 1 1.Support for scale-out up to 8 controllers 2.Excellent reliability/performance/scalability 3.Used to beat out EMC VNX, HDS HUS, and IBM DS series Architecture All-in-one unified storage 2 1.Support for coexistence of blocks and files in controller enclosures 2.Disk pool based block and file construction with high efficiency 3.Beyond other competitors' capabilities with the exception of NetApp Next-generation hardware architecture Gbps Fibre Channel or 56 Gbps IB host ports, PCIe 3.0 system bus, and 12 Gbps SAS disk ports, doubling the overall bandwidth and optimizing performance 2.Beyond competitors' capabilities 80
80 OceanStor V3 Series Advantage Highlights Inline deduplication and compression 4 1.Data deduplication/compression first and then storage, saving storage space 2.EMC/NetApp unable to support inline mode 3.Only Huawei employing deduplication/compression acceleration cards to reduce workload Software Efficiency assurance software 5 1. QoS and cache partitioning, ensuring service SLA 2. Beyond other competitors' capabilities with the exception of HDS high-end and mid-range storage and EMC high-end storage Data protection software 6 1.Volume mirroring, 5-second RPO, and quick data recovery, comprehensively protecting data. 2.Beyond competitors' capabilities 81
81 OceanStor V3 Series Advantage Highlights Others SmartIO 4-port interface module 7 1.Support for 8 Gbps or 16 Gbps Fibre Channel/10GE/FCoE 2.Configuration by user 3.Flexible adaption to network planning changes 4.Beyond other competitors' capabilities with the exception of NetApp Authentication 8 1.SPC-1 performance test report used to beat out EMC (no such report) and other competitors (lower performance) 82
82 Competition Landscape Huawei EMC NetApp IBM HP HDS DELL 6800 V3 256 GB/512 GB, 1500 disks 5800 V3 128 GB /256 GB, 1250 disks 5600 V3 64 GB/128 GB, 1000 disks VMAX100K 512 GB, 720 disks VMAX 10K 128 to 512 GB, 1500 disks VNX GB, 1500 disks VNX GB, 1000 disks FAS8080EX 256 GB, 1440 disks FAS GB, 1200 disks DS TB, 1536 disks DS GB, 1536 disks V7000 (two controllers) 128 GB, 504 disks StoreServ to 768 GB, 1920 disks StoreServ to 384 GB, 960 disks VSP 512 GB to 1 TB, 2048 disks HUS VM 256 GB, 1152 disks 5500 V3 48 GB/96 GB/128 GB, 750 disks 5300 V3 32 GB/64 GB, 500 disks VNX GB, 750 disks FAS GB, 720 disks VNX GB, 500 disks FAS GB, 480 disks V7000 (two controllers) 64 GB, 504 disks StoreServ (two controllers) to 64 GB (four controllers) 480 disks HUS GB, 960 disks Compellent SC to 128 GB, 960 disks 2600 V3 (not released) 32 GB, 500 disks 2200 V3 (not released) 8 GB/16 GB, 350 disks VNX GB, 250 disks VNX GB, 125 disks VNXe GB, 50 disks FAS GB, 144 disks FAS GB, 144 disks FAS GB, 84 disks V5000 (two controllers) 16 GB, 240 disks V GB, 120 disks V GB, 24 disks StoreServ GB, 144 disks EVA P to 16 GB, 450 disks EVA P to 8 GB, 250 disks MSA GB, 199 disks HUS GB, 264 disks HUS GB, 120 disks SC GB, 120 disks EqualLogic PS GB, 24 disks EqualLogic PS GB, 24 disks MD GB, 192 disks MD GB, 96 disks Note: 1. The analysis is based on cache capacity and disk quantity. The V3 series is configured with two controllers. This diagram is used for bidding. 83
83 OceanStor V3 series vs. EMC VNX2 series 9U VNX VNX Disk Arrays Control Station VNX X-Blade (2) VNX Block Controller (2) Architecture Capability V3 VNX Unified (file, block) x Scale out 8 2(block) functionality Thin provisioning Auto-tiering 4MB 256MB Flash Cache N + 1 power dedupe/compression inline post virtualization x Control Station (Linux OS) Manage X-Blades VNX X-Blade (DART OS) Cache partition x specification Cache size x 16 Gbps FC, SmartIO x Independent controller High-density disk enclosure VNX SP (FLARE OS) Supported disk 84
84 OceanStor V3 series vs. IBM Storwize series Architecture Capability V3 Storwize Unified (file, block) x Scale out 8 8 functionality SVC architecture + XIV management GUI. FM- two system X server, SONAS Thin provisioning Auto-tiering 4MB 256MB Flash Cache x dedupe/compression inline no dedup Inline compression virtualization Cache partition x specification Supported disk x 16 Gbps FC, 12Gbps SAS, SmartIO High-density disk enclosure
85 OceanStor V3 series vs. HP StoreServ Series Architecture Capability V3 StoreServ Unified (file, block) x Scale out 8 4 functionality Thin provisioning Auto-tiering 4MB 128MB Flash Cache dedupe/compression Additional X3830 gateways provide file service virtualization x Cache partition, QOS Multi-tenancy specification Cache/Supported disk x 16 Gbps FC, 12Gbps SAS, SmartIO Only 16Gbps FC High-density disk enclosure x 86
86 OceanStor V3 series vs. NetApp FAS Series Architecture Capability V3 FAS Unified (file, block) Scale out 8 8 functionality 7-mode and c-mode offer Different functionality Thin provisioning Auto-tiering x Flash Cache dedupe/compression inline Post (inline compression) virtualization Cache partition, QOS Multi-tenancy specification Cache/Supported disk x 16 Gbps FC, 12Gbps SAS, SmartIO 6Gbps SAS High-density disk enclosure
87 HUAWEI ENTERPRISE ICT SOLUTIONS A BETTER WAY Copyright 2012 Huawei Technologies Co., Ltd. All Rights Reserved. The information in this document may contain predictive statements including, without limitation, statements regarding the future financial and operating results, future product portfolio, new technology, etc. There are a number of factors that could cause actual results and developments to differ materially from those expressed or implied in the predictive statements. Therefore, such information is provided for reference purpose only and constitutes neither an offer nor an acceptance. Huawei may change the information at any time without notice.
Huawei OceanStor V3 Converged Storage Systems Pre-sales Training HUAWEI TECHNOLOGIES CO., LTD.
Huawei OceanStor V3 Converged Storage Systems Pre-sales Training HUAWEI TECHNOLOGIES CO., LTD. Contents 1 2 3 4 Value Proposition and Positioning Product Overview and Highlights Quotation guide Competitive
More informationHuawei OceanStor V3 Converged Storage Configuration and Quotation Guide HUAWEI TECHNOLOGIES CO., LTD.
Huawei OceanStor V3 Converged Storage Configuration and Quotation Guide Contents 1 Configuration 2 3 Quotation Configuration instances 2 OceanStor V3 series specifications Product Name 5300 V3 5500 V3
More informationCloud-Oriented Converged Storage
Cloud-Oriented Converged Storage 5600, and 5800 V3 mid-range storage systems are next-generation unified storage products specifically designed for enterprise-class applications. Employing a storage operating
More informationCloud-Oriented Converged Storage
5600, and 500 V3 Storage Systems Cloud-Oriented Converged Storage 5600, and 500 V3 mid-range storage systems are next-generation unified storage products specifically designed for enterprise-class applications.
More informationThe Best Choice for SMBs
The Best Choice for SMBs Huawei OceanStor 2600 V3 storage system are flash-oriented storage products specifically designed for enterprise-class applications. Employing a storage operating system built
More informationOceanStor 5300F&5500F& 5600F&5800F V5 All-Flash Storage Systems
OceanStor 5300F&5500F& 5600F&5800F V5 Huawei mid-range all-flash storage systems (OceanStor F V5 mid-range storage for short) deliver the high performance, low latency, and high scalability that are required
More informationOceanStor 6800F V5 Mission-Critical All-Flash Storage Systems
OceanStor 6800F V5 Mission-Critical s OceanStor 6800F V5 all-flash storage system (OceanStor 6800F V5 for short) is Huawei's next-generation mission-critical all-flash array. It has incorporated all of
More informationHuawei OceanStor 2200 V3 and 2600 V3 Storage Systems. Technical White Paper. Issue 01. Date HUAWEI TECHNOLOGIES CO., LTD.
Systems Technical White Paper Issue 01 Date 2016-04-30 HUAWEI TECHNOLOGIES CO., LTD. 2016. All rights reserved. No part of this document may be reproduced or transmitted in any form or by any means without
More informationHuawei Unified Storage Overview. HCS Storage Pre-sales Training
Huawei Unified Storage Overview HCS Storage Pre-sales Training 0 Teacher name Background Project Experience Teacher name position teachername@huawei.com +0086 1888888888 Specialist Skills 1 Page 1 Hardware
More informationLightning Fast Rock Solid
Lightning Fast Rock Solid OceanStor Dorado V3 all-flash storage is the ideal storage solution to handle mission-critical businesses for TM enterprises and organizations. Based on Huawei's unique FlashLink
More informationOceanStor T Series Configuration and Quotation Guide. Security Level:
OceanStor T Series Configuration and Quotation Guide Security Level: Contents 1 Product Overview 2 Configuration Instructions 3 Configuration Instances Overview of the T Series V001R005 Unified storage
More informationOceanStor V3 Converged Storage System Technical Proposal Template HUAWEI TECHNOLOGIES CO., LTD. Issue 1.2. Date
OceanStor V3 Converged Storage System Technical Issue 1.2 Date 2014-12 HUAWEI TECHNOLOGIES CO., LTD. Copyright Huawei Technologies Co., Ltd. 2014. All rights reserved. No part of this document may be reproduced
More informationHuawei Partner IT Product Manual
Huawei Partner IT Product Manual Storage Section HUAWEI TECHNOLOGIES CO., LTD. Huawei storage products panorama The channel storage products N8500 Clustered S Big Data & Cloud Storage CSS Distributed Storage
More informationHUAWEI OceanStor Enterprise Unified Storage System. HyperReplication Technical White Paper. Issue 01. Date HUAWEI TECHNOLOGIES CO., LTD.
HUAWEI OceanStor Enterprise Unified Storage System HyperReplication Technical White Paper Issue 01 Date 2014-03-20 HUAWEI TECHNOLOGIES CO., LTD. 2014. All rights reserved. No part of this document may
More informationHuawei OceanStor Dorado V3 All Flash Storage. Technical White Paper. Issue 1.0. Date HUAWEI TECHNOLOGIES CO., LTD.
Issue.0 Date 207-03-30 HUAWEI TECHNOLOGIES CO., LTD. 207. All rights reserved. No part of this document may be reproduced or transmitted in any form or by any means without prior written consent of Huawei
More informationWarsaw. 11 th September 2018
Warsaw 11 th September 2018 Dell EMC Unity & SC Series Midrange Storage Portfolio Overview Bartosz Charliński Senior System Engineer, Dell EMC The Dell EMC Midrange Family SC7020F SC5020F SC9000 SC5020
More informationHuawei Unified Storage Software Features Hyper and Smart Series
Huawei Unified Storage Software Features Hyper and Smart Series Date: Mar. 18, 2015 0 Teacher name Background Project Experience Teacher name position teachername@huawei.com +0086 1888888888 Specialist
More informationReconstruyendo una Nube Privada con la Innovadora Hiper-Convergencia Infraestructura Huawei FusionCube Hiper-Convergente
Reconstruyendo una Nube Privada con la Innovadora Hiper-Convergencia Infraestructura Huawei FusionCube Hiper-Convergente Ronald Paz IT Product Director Huawei del Peru Contents 1 Huawei Corporation 2 IT
More informationFully Converged Cloud Storage
Highlights Fully Converged Cloud Storage Massive scale-out storage designed for cloud architectures On-demand provisioning of block, file, and object storage on one appliance Scale out to performance and
More informationIBM Storwize V7000 Unified
IBM Storwize V7000 Unified Pavel Müller IBM Systems and Technology Group Storwize V7000 Position Enterprise Block DS8000 For clients requiring: Advanced disaster recovery with 3-way mirroring and System
More informationIntroducing Tegile. Company Overview. Product Overview. Solutions & Use Cases. Partnering with Tegile
Tegile Systems 1 Introducing Tegile Company Overview Product Overview Solutions & Use Cases Partnering with Tegile 2 Company Overview Company Overview Te gile - [tey-jile] Tegile = technology + agile Founded
More informationOceanStor T Series V200R002 Sales Guide
OceanStor T Series V200R002 Sales Guide Contents What Introduction to T series V200R002 Where Positioning of T series V200R002 How Sales strategies of T series V200R002 1 Global/China ECB market shares
More informationThe Fastest Scale-Out NAS
The Fastest Scale-Out NAS The features a symmetric distributed architecture that delivers superior performance, extensive scale-out capabilities, and a super-large single file system providing shared storage
More informationIBM EXAM QUESTIONS & ANSWERS
IBM 000-452 EXAM QUESTIONS & ANSWERS Number: 000-452 Passing Score: 800 Time Limit: 120 min File Version: 68.8 http://www.gratisexam.com/ IBM 000-452 EXAM QUESTIONS & ANSWERS Exam Name: IBM Storwize V7000
More informationСистемы хранения IBM. Новые возможности
Системы хранения IBM Новые возможности Introducing: A New Member of the Storwize Family Easy to use, affordable and efficient storage for Small and Medium Businesses New standard for midrange storage IBM
More informationDell Fluid Data solutions. Powerful self-optimized enterprise storage. Dell Compellent Storage Center: Designed for business results
Dell Fluid Data solutions Powerful self-optimized enterprise storage Dell Compellent Storage Center: Designed for business results The Dell difference: Efficiency designed to drive down your total cost
More informationHUAWEI OceanStor VIS6600T Product Presales Training
HUAWEI OceanStor VIS6600T Product Presales Training Contents 1 2 Market Overview and Product Positioning Highlights 3 Product Comparison 4 5 Success Stories Ordering Guide 6 How to Obtain Resources 2 Market
More informationHitachi Virtual Storage Platform Family
Hitachi Virtual Storage Platform Family Advanced Storage Capabilities for All Organizations Andre Lahrmann 23. November 2017 Hitachi Vantara Vorweg: Aus Hitachi Data Systems wird Hitachi Vantara The efficiency
More informationNEC M100 Frequently Asked Questions September, 2011
What RAID levels are supported in the M100? 1,5,6,10,50,60,Triple Mirror What is the power consumption of M100 vs. D4? The M100 consumes 26% less energy. The D4-30 Base Unit (w/ 3.5" SAS15K x 12) consumes
More informationAll (about) Flash Array storage and efficient hybrid storage. Brinel, 23 Ianuarie 2018
All (about) Flash Array storage and efficient hybrid storage Brinel, 23 Ianuarie 2018 bogdan.dinca@dell.com Digital Transformation Opportunity or Risk? 48% 45% 92% Have no idea what their industry will
More informationWhite Paper Features and Benefits of Fujitsu All-Flash Arrays for Virtualization and Consolidation ETERNUS AF S2 series
White Paper Features and Benefits of Fujitsu All-Flash Arrays for Virtualization and Consolidation Fujitsu All-Flash Arrays are extremely effective tools when virtualization is used for server consolidation.
More informationDATA PROTECTION IN A ROBO ENVIRONMENT
Reference Architecture DATA PROTECTION IN A ROBO ENVIRONMENT EMC VNX Series EMC VNXe Series EMC Solutions Group April 2012 Copyright 2012 EMC Corporation. All Rights Reserved. EMC believes the information
More informationECONOMICAL, STORAGE PURPOSE-BUILT FOR THE EMERGING DATA CENTERS. By George Crump
ECONOMICAL, STORAGE PURPOSE-BUILT FOR THE EMERGING DATA CENTERS By George Crump Economical, Storage Purpose-Built for the Emerging Data Centers Most small, growing businesses start as a collection of laptops
More informationVirtual Desktop Infrastructure (VDI) Bassam Jbara
Virtual Desktop Infrastructure (VDI) Bassam Jbara 1 VDI Historical Overview Desktop virtualization is a software technology that separates the desktop environment and associated application software from
More informationHigh performance and functionality
IBM Storwize V7000F High-performance, highly functional, cost-effective all-flash storage Highlights Deploys all-flash performance with market-leading functionality Helps lower storage costs with data
More informationNew HPE 3PAR StoreServ 8000 and series Optimized for Flash
New HPE 3PAR StoreServ 8000 and 20000 series Optimized for Flash AGENDA HPE 3PAR StoreServ architecture fundamentals HPE 3PAR Flash optimizations HPE 3PAR portfolio overview HPE 3PAR Flash example from
More informationBest Practices of Huawei SAP HANA TDI Active-Passive DR Solution Using BCManager. Huawei Enterprise BG, IT Storage Solution Dept Version 1.
Best Practices of Huawei SAP HANA TDI Active-Passive DR Solution Using BCManager Huawei Enterprise BG, IT Storage Solution Dept 2017-8-20 Version 1.0 Contents 1 About This Document... 3 1.1 Overview...
More informationThe storage challenges of virtualized environments
The storage challenges of virtualized environments The virtualization challenge: Ageing and Inflexible storage architectures Mixing of platforms causes management complexity Unable to meet the requirements
More informationBest Practices of Huawei SAP HANA TDI Solution Using OceanStor Dorado V3. Huawei Enterprise BG, IT Storage Solution Dept Version 1.
Best Practices of Huawei SAP HANA TDI Solution Using OceanStor Dorado V3 Huawei Enterprise BG, IT Storage Solution Dept 2017-7-31 Version 1.0 Contents 1 About This Document... 3 1.1 Overview... 3 1.2 Purpose...
More informationDisruptive Forces Affecting the Future
Michel Bakker Disruptive Forces Affecting the Future proof to the POWER8 architecture leadership What new innovation? Can t you see I m too busy? Semiconductor Scaling: No More Moore 2016:
More informationEMC Business Continuity for Microsoft Applications
EMC Business Continuity for Microsoft Applications Enabled by EMC Celerra, EMC MirrorView/A, EMC Celerra Replicator, VMware Site Recovery Manager, and VMware vsphere 4 Copyright 2009 EMC Corporation. All
More informationTHE SUMMARY. CLUSTER SERIES - pg. 3. ULTRA SERIES - pg. 5. EXTREME SERIES - pg. 9
PRODUCT CATALOG THE SUMMARY CLUSTER SERIES - pg. 3 ULTRA SERIES - pg. 5 EXTREME SERIES - pg. 9 CLUSTER SERIES THE HIGH DENSITY STORAGE FOR ARCHIVE AND BACKUP When downtime is not an option Downtime is
More informationVMware Virtual SAN. Technical Walkthrough. Massimiliano Moschini Brand Specialist VCI - vexpert VMware Inc. All rights reserved.
VMware Virtual SAN Technical Walkthrough Massimiliano Moschini Brand Specialist VCI - vexpert 2014 VMware Inc. All rights reserved. VMware Storage Innovations VI 3.x VMFS Snapshots Storage vmotion NAS
More informationReliable Efficient Elastic
Reliable Efficient Elastic Highlights Massive scale-out storage designed for cloud architectures On-demand provisioning of block, file, or object storage Scale out to performance and capacity on demand,
More informationHUAWEI OceanStor T Series V2 Unified Storage Pre-sales Specialist Training. Version: V1.0( )
HUAWEI OceanStor T Series V2 Unified Storage Pre-sales Specialist Training Version: V1.0(2014-3-12) Agenda 1 Market Overview and Click Positioning to add Title 2 Highlights 3 Product Comparison Click to
More informationTegile Enters the All-Flash Array Market with Super Density Offering
FLASH Tegile Enters the All-Flash Array Market with Super Density Offering Eric Burgener IN THIS FLASH This IDC Flash discusses the recent Tegile announcement, just prior to VMworld 2015 in San Francisco,
More informationVerron Martina vspecialist. Copyright 2012 EMC Corporation. All rights reserved.
Verron Martina vspecialist 1 TRANSFORMING MISSION CRITICAL APPLICATIONS 2 Application Environments Historically Physical Infrastructure Limits Application Value Challenges Different Environments Limits
More informationIBM Storage Software Strategy
IBM Storage Software Strategy Hakan Turgut 1 Just how fast is the data growing? 128 GB/ person The World s total data per person No Problem I I think I can do this We have a problem 24 GB/ person 0.8 GB/
More informationNutanix Tech Note. Virtualizing Microsoft Applications on Web-Scale Infrastructure
Nutanix Tech Note Virtualizing Microsoft Applications on Web-Scale Infrastructure The increase in virtualization of critical applications has brought significant attention to compute and storage infrastructure.
More informationCopyright 2012 EMC Corporation. All rights reserved.
1 TRANSFORMING MICROSOFT APPLICATIONS TO THE CLOUD Louaye Rachidi Technology Consultant 2 22x Partner Of Year 19+ Gold And Silver Microsoft Competencies 2,700+ Consultants Worldwide Cooperative Support
More informationNext Gen Storage StoreVirtual Alex Wilson Solutions Architect
Next Gen Storage StoreVirtual 3200 Alex Wilson Solutions Architect NEW HPE StoreVirtual 3200 Storage Low-cost, next-gen storage that scales with you Start at < 5K* and add flash when you are ready Supercharge
More informationIT Certification Exams Provider! Weofferfreeupdateserviceforoneyear! h ps://
IT Certification Exams Provider! Weofferfreeupdateserviceforoneyear! h ps://www.certqueen.com Exam : 000-115 Title : Storage Sales V2 Version : Demo 1 / 5 1.The IBM TS7680 ProtecTIER Deduplication Gateway
More informationEMC & VMWARE STRATEGIC FORUM NEW YORK MARCH David Goulden President & COO. Copyright 2013 EMC Corporation. All rights reserved.
1 EMC & VMWARE STRATEGIC FORUM NEW YORK MARCH 13 2013 David Goulden President & COO 2 The Business Drivers Increase Revenue Lower Operational Costs Reduce Risk 3 CLOUD TRANSFORMS IT Lower Operational Costs
More informationIntroduction to NetApp E-Series E2700 with SANtricity 11.10
d Technical Report Introduction to NetApp E-Series E2700 with SANtricity 11.10 Todd Edwards, NetApp March 2014 TR-4275 1 Introduction to NetApp E-Series E2700 with SANtricity 11.10 TABLE OF CONTENTS 1
More informationVendor: IBM. Exam Code: Exam Name: IBM Midrange Storage Technical Support V3. Version: Demo
Vendor: IBM Exam Code: 000-451 Exam Name: IBM Midrange Storage Technical Support V3 Version: Demo QUESTION NO: 1 On the Storwize V7000, which IBM utility analyzes the expected compression savings for an
More informationWhite Paper. EonStor GS Family Best Practices Guide. Version: 1.1 Updated: Apr., 2018
EonStor GS Family Best Practices Guide White Paper Version: 1.1 Updated: Apr., 2018 Abstract: This guide provides recommendations of best practices for installation and configuration to meet customer performance
More informationCopyright 2012, Oracle and/or its affiliates. All rights reserved.
1 Storage Innovation at the Core of the Enterprise Robert Klusman Sr. Director Storage North America 2 The following is intended to outline our general product direction. It is intended for information
More informationOceanStor 5000F and 6000F V5 Series V500R007. Product Description. Issue 02 Date HUAWEI TECHNOLOGIES CO., LTD.
V500R007 Issue 02 Date 2018-01-30 HUAWEI TECHNOLOGIES CO., LTD. 2018. All rights reserved. No part of this document may be reproduced or transmitted in any form or by any means without prior written consent
More informationIsilon Scale Out NAS. Morten Petersen, Senior Systems Engineer, Isilon Division
Isilon Scale Out NAS Morten Petersen, Senior Systems Engineer, Isilon Division 1 Agenda Architecture Overview Next Generation Hardware Performance Caching Performance SMB 3 - MultiChannel 2 OneFS Architecture
More informationHPE MSA 2042 Storage. Data sheet
HPE MSA 2042 Storage HPE MSA 2042 Storage offers an entry storage platform with built-in hybrid flash for application acceleration and high performance. It is ideal for performance-hungry applications
More informationMoving to dynamic utility Storage for cloud computing Craig Nunes
Moving to dynamic utility Storage for cloud computing Craig Nunes Vice President of Marketing HP Storage Storage workflow in an unpredictable world 1 Store Massive scale, virtualized, app proliferation,
More informationVendor: IBM. Exam Code: Exam Name: Storage Sales V2. Version: DEMO
Vendor: IBM Exam Code: 000-115 Exam Name: Storage Sales V2 Version: DEMO 1.Which of the following customer requirements is the TS7650G Gateway designed to address? A. latency across a long distance network
More informationVMware Virtual SAN Technology
VMware Virtual SAN Technology Today s Agenda 1 Hyper-Converged Infrastructure Architecture & Vmware Virtual SAN Overview 2 Why VMware Hyper-Converged Software? 3 VMware Virtual SAN Advantage Today s Agenda
More informationBenefits of Multi-Node Scale-out Clusters running NetApp Clustered Data ONTAP. Silverton Consulting, Inc. StorInt Briefing
Benefits of Multi-Node Scale-out Clusters running NetApp Clustered Data ONTAP Silverton Consulting, Inc. StorInt Briefing BENEFITS OF MULTI- NODE SCALE- OUT CLUSTERS RUNNING NETAPP CDOT PAGE 2 OF 7 Introduction
More informationToday s trends in the storage world. Jacint Juhasz Storage Infrastructure Architect
Today s trends in the storage world Jacint Juhasz Storage Infrastructure Architect NetApp storage portfolio All-Flash Arrays for highest performance All-Flash SolidFire Data ONTAP-v for public cloud All
More informationHuawei IT Product and Solution
Huawei IT Product and Solution Make IT Simple Make Business Agile HUAWEI TECHNOLOGIES CO., LTD. Make IT Simple, Make Business Agile. Huawei IT Product Line focuses on IT infrastructure, and helps enterprises
More informationEMC Backup and Recovery for Microsoft Exchange 2007
EMC Backup and Recovery for Microsoft Exchange 2007 Enabled by EMC CLARiiON CX4-120, Replication Manager, and Hyper-V on Windows Server 2008 using iscsi Reference Architecture Copyright 2009 EMC Corporation.
More informationEMC Integrated Infrastructure for VMware. Business Continuity
EMC Integrated Infrastructure for VMware Business Continuity Enabled by EMC Celerra and VMware vcenter Site Recovery Manager Reference Architecture Copyright 2009 EMC Corporation. All rights reserved.
More informationNimble Storage Adaptive Flash
Nimble Storage Adaptive Flash Read more Nimble solutions Contact Us 800-544-8877 solutions@microage.com MicroAge.com TECHNOLOGY OVERVIEW Nimble Storage Adaptive Flash Nimble Storage s Adaptive Flash platform
More informationHuawei OceanStor 9000 Scale-Out NAS. Technical White Paper. Issue 05. Date HUAWEI TECHNOLOGIES CO., LTD.
Issue 05 Date 2017-01-20 HUAWEI TECHNOLOGIES CO., LTD. 2017. All rights reserved. No part of this document may be reproduced or transmitted in any form or by any means without prior written consent of
More informationHUAWEI TECHNOLOGIES CO., LTD HUAWEI OCEANSTOR 5300 V5
EXECUTIVE SUMMARY SPC BENCHMARK 1 EXECUTIVE SUMMARY HUAWEI TECHNOLOGIES CO., LTD HUAWEI OCEANSTOR 5300 V5 SPC-1 IOPS 450,212 SPC-1 Price-Performance $416.27/SPC-1 KIOPS SPC-1 IOPS Response Time 0.577 ms
More informationEMC Corporation. Tony Takazawa Vice President, EMC Investor Relations. August 5, 2008
1 EMC Corporation Tony Takazawa Vice President, EMC Investor Relations August 5, 2008 2 Forward-Looking Statements This presentation contains forward-looking statements as defined under the Federal Securities
More informationHPE Storage Update The All Flash Datacenter 3PAR
Horizont 2016 HPE Storage Update The All Flash Datacenter 3PAR James Hall EMEA Pre-Sales Strategy Copyright 2015 Hewlett Packard Enterprise Development LP October 2016 Agenda 1 2 Business Challanges HPE
More informationExam : Title : Storage Sales V2. Version : Demo
Exam : 000-115 Title : Storage Sales V2 Version : Demo 1.The IBM TS7680 ProtecTIER Deduplication Gateway for System z solution is designed to provide all of the following EXCEPT: A. ESCON attach to System
More informationDynamically unify your data center Dell Compellent: Self-optimized, intelligently tiered storage
Dell Fluid Data architecture Dynamically unify your data center Dell Compellent: Self-optimized, intelligently tiered storage Dell believes that storage should help you spend less while giving you the
More informationWhite Paper. A System for Archiving, Recovery, and Storage Optimization. Mimosa NearPoint for Microsoft
White Paper Mimosa Systems, Inc. November 2007 A System for Email Archiving, Recovery, and Storage Optimization Mimosa NearPoint for Microsoft Exchange Server and EqualLogic PS Series Storage Arrays CONTENTS
More informationFAST & Furious mit EMC² VNX
FAST & Furious mit EMC² VNX EMC Forum 2011 1 Topics What we ll cover in the next 30 minutes VNX(e) Introduction Video Flash 1 st 2 Next Generation Unified Storage Optimized for today s virtualized IT Unisphere
More informationVendor: Hitachi. Exam Code: HH Exam Name: Hitachi Data Systems Storage Fondations. Version: Demo
Vendor: Hitachi Exam Code: HH0-130 Exam Name: Hitachi Data Systems Storage Fondations Version: Demo QUESTION: 1 A drive within a HUS system reaches its read error threshold. What will happen to the data
More informationConverged Storage Makes Business Agile
Converged Storage Makes Business Agile About Huawei: Leverage worldwide top talents Global R&D Center US R&D Center Architecture team Open Stack R&D BD &PM Europe R&D Center Security capability center
More informationVMware vsphere 5.0 STORAGE-CENTRIC FEATURES AND INTEGRATION WITH EMC VNX PLATFORMS
VMware vsphere 5.0 STORAGE-CENTRIC FEATURES AND INTEGRATION WITH EMC VNX PLATFORMS A detailed overview of integration points and new storage features of vsphere 5.0 with EMC VNX platforms EMC Solutions
More informationHPE Storage news. Mauro Colombo Hybrid IT sales & presales manager 23 rd May 2018
HPE Storage news Mauro Colombo Hybrid IT sales & presales manager 23 rd May 2018 1 Agenda 1. It s all about flash 2. HPE Primary storage news Nimble Gen5 3PAR OS 3.3.1 HPE Infosight for 3PAR 3. HPE solutions
More informationHow To Get The Most Out Of Flash Deployments
How To Get The Most Out Of Flash Deployments PRESENTATION TITLE GOES HERE Eric Burgener Research Director, Storage Practice IDC Flash: A Must Have Storage performance req ts very different in virtual infrastructure
More informationHigh Volumes Storage Fundamentials V2
High Volumes Storage Fundamentials V2 Number: 000-955 Passing Score: 680 Time Limit: 90 min http://www.gratisexam.com/ IBM EXAM 000-955 High Volume Storage Fundamentals V2 Total Questions: 69 Exam A QUESTION
More informationTHE EMC ISILON STORY. Big Data In The Enterprise. Deya Bassiouni Isilon Regional Sales Manager Emerging Africa, Egypt & Lebanon.
THE EMC ISILON STORY Big Data In The Enterprise Deya Bassiouni Isilon Regional Sales Manager Emerging Africa, Egypt & Lebanon August, 2012 1 Big Data In The Enterprise Isilon Overview Isilon Technology
More informationMainframe Backup Modernization Disk Library for mainframe
Mainframe Backup Modernization Disk Library for mainframe Mainframe is more important than ever itunes Downloads Instagram Photos Twitter Tweets Facebook Likes YouTube Views Google Searches CICS Transactions
More informationIBM Storwize V5000 disk system
IBM Storwize V5000 disk system Latest addition to IBM Storwize family delivers outstanding benefits with greater flexibility Highlights Simplify management with industryleading graphical user interface
More informationSPECIFICATION FOR NETWORK ATTACHED STORAGE (NAS) TO BE FILLED BY BIDDER. NAS Controller Should be rack mounted with a form factor of not more than 2U
SPECIFICATION FOR NETWORK ATTACHED STORAGE (NAS) TO BE FILLED BY BIDDER S.No. Features Qualifying Minimum Requirements No. of Storage 1 Units 2 Make Offered 3 Model Offered 4 Rack mount 5 Processor 6 Memory
More informationHuawei OceanStor ReplicationDirector Software Technical White Paper HUAWEI TECHNOLOGIES CO., LTD. Issue 01. Date
Huawei OceanStor Software Issue 01 Date 2015-01-17 HUAWEI TECHNOLOGIES CO., LTD. 2015. All rights reserved. No part of this document may be reproduced or transmitted in any form or by any means without
More informationThe Best Storage for Virtualized Environments
The Best Storage for Virtualized Environments Paul Kessler Asia Pacific Solutions Marketing Alliances, NetApp Nov.4,2008 The Best Storage for Virtualized Environments Paul Kessler Solutions Marketing &
More informationIBM System Storage DCS3700
IBM System Storage DCS3700 Maximize performance, scalability and storage density at an affordable price Highlights Gain fast, highly dense storage capabilities at an affordable price Deliver simplified
More informationThinking Different: Simple, Efficient, Affordable, Unified Storage
Thinking Different: Simple, Efficient, Affordable, Unified Storage EMC VNX Family Easy yet Powerful 1 IT Challenges: Tougher than Ever Four central themes facing every decision maker today Overcome flat
More informationCopyright 2012 EMC Corporation. All rights reserved.
1 FLASH 1 ST THE STORAGE STRATEGY FOR THE NEXT DECADE Richard Gordon EMEA FLASH Business Development 2 Information Tipping Point Ahead The Future Will Be Nothing Like The Past 140,000 120,000 100,000 80,000
More informationINTRODUCING VNX SERIES February 2011
INTRODUCING VNX SERIES Next Generation Unified Storage Optimized for today s virtualized IT Unisphere The #1 Storage Infrastructure for Virtualisation Matthew Livermore Technical Sales Specialist (Unified
More informationCopyright 2012 EMC Corporation. All rights reserved.
1 TRANSFORMING MISSION CRITICAL APPLICATIONS 2 Application Environments Historically Physical Infrastructure Limits Application Value Challenges Different Environments Limits On Performance Underutilized
More informationNové možnosti storage virtualizace s řešením IBM Storwize V7000
Nové možnosti storage virtualizace s řešením IBM Storwize V7000 A new generation of midrange storage Rudolf Hruška Information Infrastructure Leader IBM Systems & Technology Group rudolf_hruska@cz.ibm.com
More informationDell PowerVault MD Family. Modular storage. The Dell PowerVault MD storage family
Dell PowerVault MD Family Modular storage The Dell PowerVault MD storage family Dell PowerVault MD Family The affordable choice The Dell PowerVault MD family is an affordable choice for reliable storage.
More informationPower of the Portfolio. Copyright 2012 EMC Corporation. All rights reserved.
Power of the Portfolio 1 VMAX / VPLEX K-12 School System District seeking system to support rollout of new VDI implementation Customer found Vblock to be superior solutions versus competitor Customer expanded
More informationVeritas Storage Foundation from Symantec
Simplified, Scalable and Cost-Effective Storage Management Overviewview provides a complete solution for heterogeneous online storage management. Based on the industry-leading Veritas Volume Manager from
More informationNimble Storage vs HPE 3PAR: A Comparison Snapshot
Nimble Storage vs HPE 3PAR: A 1056 Baker Road Dexter, MI 48130 t. 734.408.1993 Nimble Storage vs HPE 3PAR: A INTRODUCTION: Founders incorporated Nimble Storage in 2008 with a mission to provide customers
More informationHuawei OceanStor Dorado V3 All Flash Storage Reference Architecture for Performance Optimization and Data Migration of VMware Horizon View
Huawei OceanStor Dorado V3 All Flash Storage Reference Architecture for Performance Optimization and Data Migration of VMware Horizon View OceanStor Dorado V3 series products (Dorado V3 for short) are
More information