1 TLE 20 MICROPROCESSOR-BASED DIGITAL ELECTRIC FREEZER CTROLLER OPERATING INSTRUCTIS Vr. 0 (ENG) - 09/0 - co.: ISTR 0720 FOREWORD TECNOLOGIC S.p.A. VIA INDIPENDENZA VIGEVANO (PV) ITALY TEL.: FAX: internet : info@tecnologic.it INDEX INSTRUMENT DESCRIPTI GENERAL DESCRIPTI FRT PANEL DESCRIPTI PROGRAMMING PROGRAMMING OF SET POINT PARAMETERS PROGRAMMING PARAMETER PROTECTI USING THE PASSWORD PARAMETERS PROGRAMMING LEVEL INFORMATI INSTALLATI AND USE PERMITTED USE MECHANICAL MOUNTING ELECTRICAL CNECTIS ELECTRICAL WIRING DIAGRAM FUNCTIS / STAND-BY FUNCTI MEASURING AND VISUALIZATI TEMPERATURE CTROL COMPRESSOR PROTECTI FUNCTI AND DELAY AT POWER- DEFROST CTROL MANUAL DEFROST PARAMETERS CFIGURATI BY KEY0 PROGRAMMABLE PARAMETERS TABLE PROBLEMS, MAINTENANCE AND GUARANTEE SIGNALLING CLEANING GUARANTEE AND REPAIRS TECHNICAL DATA ELECTRICAL DATA MECHANICAL DATA MECHANICAL DIMENSIS, PANEL CUT- AND MOUNTING FUNCTIAL DATA INSTRUMENT ORDERING CODE Out 3 This manual contains the information 4 necessary for the prouct to be installe 2 correctly an also instructions for its AL maintenance an use; we therefore recommen SET that the utmost attention is pai to the following 7 instructions an to save it. This ocument is the exclusive property of TECNOLOGIC - Key P : Use for setting the Set point an for programming the S.p.A. which forbis any reprouction an ivulgation, even function parameters in part, of the ocument, unless expressly authorize. 2 - Key DOWN : Use for ecreasing the values to be set an for TECNOLOGIC S.p.A. reserves the right to make any formal or selecting the parameters. It can be programme via the parameter functional changes at any moment an without any notice. Fb to turning on an (stan-by) the evice. Whenever a failure or a malfunction of the evice may cause 3 - Key UP/DEFROST : Use for increasing the value to be set, for angerous situations for persons, thing or animals, please selecting the parameters an for activating manual efrosting. remember that the plant has to be equippe with aitional 4 - Le : Inicates the compressor output status (or the evices which will guarantee safety. temperature control evice) on (on), () or inhibite (flashing). Tecnologic S.p.A. an its legal representatives o not assume - Le AL : Inicates the alarm status (on), () or silence any responsibility for any amage to people, things or animals (flashing). eriving from violation, wrong or improper use or in any case - Le DEF : Inicates efrosting in progress not in compliance with the instrument s features INSTRUMENT DESCRIPTI. - GENERAL DESCRIPTI The moel TLE 20 is a igital controller with microprocessor that is typically use in cooling applications that have temperature control with /OFF regulation an efrosting control with set by means of stopping compressor. The instrument has one relay output an one input for PTC or NTC temperature probes. The instrument is equippe with 3 programme keys, a 2 ½ igit isplay an 3 LED signals..2 - FRT PANEL DESCRIPTI Def TLE 20 TECNOLOGIC - TLE 20 - OPERATING INSTRUCTIS - Vr. 0-09/0 - ISTR PAG.

2 7 - Le SET : Inicates the input in programming moe an the programming level of the parameters. It also serves to inicate the Stan-by status. 2 - PROGRAMMING 2. - PROGRAMMING OF THE SET POINT Press the key P then release it an the isplay will show alternating with the set value. To change it press the UP key to increase the value or DOWN to ecrease it. These keys increase or ecrease the value one igit at a, but if the button is presse for more than one secon the value increase or ecreases rapily, an after two secons presse, the spee increases even more to all the esire value to be reache rapily. Exiting the Set moe is achieve by pressing the P key or automatically if no key is presse for secons. After that the isplay returns to the normal function moe PARAMETERS PROGRAMMING To access the instrument s function parameters, press the key P an keep it presse for about secons, after which the SET le will light up, the isplay will visualise the coe that ientifies the first parameter. Using the UP an DOWN keys, the esire parameter can be selecte an pressing the P key, the isplay will alternately show the parameter coe an its setting that can be change with the UP an DOWN keys. Once the esire value has been set, press the key P again: the new value will be memorise an the isplay will show only the coe of the selecte parameter. Pressing the UP an DOWN keys, it is possible to select another parameter an change it as escribe. To exit the programming moe, o not press any key for about 20 secons, or keep the UP or DOWN key presse until it exits the programming moe PARAMETER PROTECTI USING THE PASSWORD The instrument has a parameter protection function using a passwor that can be personalise, through the PP parameter. If one wishes to have this protection, set the passwor number esire in the parameter PP. When the protection is working, press the P key to access the parameters an keep it press for about secons, after which the LED SET will flash an the isplay will show 0. At this point, using the UP an DOWN keys, set the passwor number programme an press the key "P". If the passwor is correct, the isplay will visualise the coe that ientifies the first parameter an it will be possible to programme the instrument in the same ways escribe in the previous section. Protection using a passwor can be isable by setting the parameter PP = PARAMETERS PROGRAMMING LEVELS The instrument has two parameter programming levels. The first level ( visible parameters) is accesse accoring to the proceure escribe above (with or without passwor request) while the secon level ( hien passwor) can be accesse accoring to the following proceure. Remove the power supply to the instrument, press the key P an return power to the instrument, keeping the key presse. After about sec. the isplay will show the coe that ientifies the first parameter an it will be possible to set the parameters of the instrument using the same programming proceure escribe previously. Once the parameter has been selecte an the SET is on, it means that the parameter can be programme even on the first level ("visible ). If the le is it means that the parameter can only be programme on this level (i.e. hien ). To change the visibility of the parameter, press an keep presse the key P while acting on UP key: the le SET will change status, inicating the accessibility level of the parameter (on = parameter visible ; = parameter hien ). The access proceure for hien parameters allows the PP parameter to be checke an change, an is useful therefore if the passwor set has been forgotten. 3 - INFORMATI INSTALLATI AND USE 3. - PERMITTED USE The instrument has been projecte an manufacture as a measuring an control evice to be use accoring to EN0730- for the altitues operation until 2000 ms. The use of the instrument for applications not expressly permitte by the above mentione rule must aopt all the necessary protective measures. The instrument CANNOT be use in angerous environments (flammable or explosive) without aequate protection. The installer must ensure that EMC rules are respecte, also after the instrument installation, if necessary using proper filters. Whenever a failure or a malfunction of the evice may cause angerous situations for persons, thing or animals, please remember that the plant has to be equippe with aitional evices which will guarantee safety MECHANICAL MOUNTING The instrument, in case 33 x 7 mm, is esigne for flush-in panel mounting. Make a hole 29 x 7 mm an insert the instrument, fixing it with the provie special brackets. We recommen that the gasket is mounte in orer to obtain the front protection egree as eclare. Avoi placing the instrument in environments with very high humiity levels or irt that may create conensation or introuction of conuctive substances into the instrument. Ensure aequate ventilation to the instrument an avoi installation in containers that house evices which may overheat or which may cause the instrument to function at a higher temperature than the one permitte an eclare. Connect the instrument as far away as possible from sources of electromagnetic isturbances such as motors, power relays, relays, solenoi valves, etc ELECTRICAL CNECTI Carry out the electrical wiring by connecting only one wire to each terminal, accoring to the following iagram, checking that the power supply is the same as that inicate on the instrument an that the loa current absorption is no higher than the maximum electricity current permitte. As the instrument is built-in equipment with permanent connection insie housing, it is not equippe with either switches or internal evices to protect against overloa of current: the installation will inclue an overloa protection an a two-phase circuit-breaker, place as near as possible to the instrument, an locate in a position that can easily be reache by the user an marke as instrument isconnecting evice which interrupts the power supply to the equipment. It is also recommene that the supply of all the electrical circuits connecte to the instrument must be protect properly, using evices (ex. fuses) proportionate to the circulating currents. It is strongly recommene that cables with proper insulation, accoring to the working voltages an temperatures, be use. Furthermore, the input cable of the probe has to be kept separate from line voltage wiring. If the input cable of the probe is screene, it has to be connecte to the groun with only one sie. Whether the instrument is 2 V version it s recommene to use an external transformer TCTR, or with equivalent features, an to use only one transformer for each instrument because there is no insulation between supply an input. We recommen that a check shoul be mae that the parameters are those esire an that the application functions correctly before connecting the outputs to the actuators so as to avoi malfunctioning that may cause irregularities in the plant that coul cause amage to people, things or animals. TECNOLOGIC - TLE 20 - OPERATING INSTRUCTIS - Vr. 0-09/0 - ISTR PAG. 2

3 3.4 - ELECTRICAL WIRING DIAGRAM SUPPLY 4 - FUNCTIS DT A-AC C NC NO INPUT PTC-NTC PROBE 4. - / STAND-BY FUNCTI The instrument, once powere up, can assume 2 ifferent conitions: - : means that the controller uses the control functions. - STAND-BY : means that the controller oes not use any control function an the isplay is turne except for the SET le. If there is no power, an then power returns, the system always sets itself in the conition it was in before the black-out. The /Stan-by function can be selecte using the key DOWN if parameter "Fb" =. The parameter Fb can be configure as follows: = - The key DOWN carries out no function. = - Pressing the key for at least secon, it is possible to switch the instrument from the status to Stan-by status an vice versa MEASURING AND VISUALIZATI Via the parameter SE it is possible to select the type of probes that one wishes to use an which can be: thermistores PTC KTY8-2 () or NTC 03AT-2 (nt). Once the type of probe use has been selecte, through the parameter ru, it is possible to select the temperature unit of measurement ( C or F) an, through the parameter P, the resolution of the esire measurement (= ; on =0, ). The instrument allows the measuring to be calibrate, that can be use for re-calibrating the instrument accoring to application nees, through the parameters CA. Using the parameter Ft, it is possible to set the constant for the software filter for measuring the input values to be able to reuce the sensitivity to measurement isturbances (increasing the ). Please remember that visualisation of the probe can be change by the isplay block in efrosting function too, by using the parameter L (see par. 4.) TEMPERATURE CTROL The regulation of the instrument is /OFF an acts on the output epening on the measuring of probe, of the Set Point, the intervention ifferential an the function moe HC. Depening on the function moe programme on the parameter HC the ifferential is automatically consiere by the regulator with positive values for a Refrigeration control ( HC =C) or with negative values for a heating control ( HC =H). In the event of probe error, it is possible to set the instrument so that that the output continues to work in cycles accoring to the s programme in the parameter t (activation ) an t2 (eactivation ). If an error occurs on the probe the instrument activates the output for the t, then eactivates it for the t2 an so on whilst the error remains. Programming t = the output in probe error conition will remain switche. Programming instea t to any value an t2 = the output in probe error conition will remain switche on. Remember that the temperature regulation function can be conitione by the Compressor Protection function escribe below. HC=C HC=H COMPRESSOR PROTECTI FUNCTI AND DELAY AT POWER- The function Compressor Protection carrie out by the machine aims to avoi close start ups of the compressor controlle by the instrument in cooling applications. This function foresees a control on the switching on of the output associate with the temperature regulation request. The protection consists of preventing the output being switche on uring the set in the parameter an counte epening on what has been programme in the parameter PS, an therefore that any activation occurs only after the has finishe. If uring the power on elay phase, the regulator request shoul isappear, ue to an inhibition cause by the compressor protection function, the foreseen start up of the output is naturally cancelle. Using the parameter PS", it is possible to set the type of compressor protection an therefore from when the inhibition must start. The parameter PS can be set as: = : Power on elay = 2 : Delay after power "PS " = "P S" = 2 = 3 : Delay between power on phases. "PS" = 3 The function is isable by programming = 0. During the power on elay phases of the output by inhibiting the function Compressor Protection the le flashes. It is also possible to prevent activation of the output after the instrument is turne on, for the set in the parameter o. The function is isable by o =. During the power on elay phase, the isplay shows the inication o, alternating with the normal programme visualisation. TECNOLOGIC - TLE 20 - OPERATING INSTRUCTIS - Vr. 0-09/0 - ISTR PAG. 3

4 4. - DEFROST CTROL The automatic control of efrost, that is by stopping compressor, occours accoring to this parameters: "C" : Defrost interval computation - rt - base on real (instrument on) - ct - base only on compressor running (output on) "i" : Interval between efrost cycles (hrs.) SUPPLY ADAPTER "n" : Interval between efrost cycles () 2 VDC AC SUPPLY "E" : Lenght of efrost cycles The instrument switch the output for the E each [ i + For aitional info, please have a look at the KEY0 instruction n ] (of real functioning if C = rt, or of compressor manual. running if C = ct). - PROGRAMMABLE PARAMETERS TABLE Instrument supplie from the evice Defrost (ex. with C = rt) i + n E (DEFROST) i + n The occurring efrost cycle is signalize by the le DEF. Through par. L, Et an A it s possible to efine the isplay behaviour uring efrost. The L parameter pemits the isplay visualization lock on the last temperature reaing (L = on) uring all the efrost cycle until, at the en of efrost, the temperature has not reache the value [ + Et] or is ene the sette on par. "A". Or it permits the visualization of label "F" ( L = Lb) uring the efrost cycle an, after the efrost, of label "P" until, at the en of efrost, the temperature has not reache the value [ + Et] or is ene the sette on par. "A". The isplay will otherwise continue to visualize the temperature measure by the probe uring the efrost cycle ( L = ) MANUAL DEFROST To start up a manual efrosting cycle, press the key UP/DEFROST when it is not in programming moe an keep it presse for about secons after which, if the conitions are correct, the le DEF will light up an the instrument will carry out a efrosting cycle PARAMETERS CFIGURATI BY KEY0 As option the instrument can be equippe with a connector that allows the transfer from an towar the instrument of the functioning parameters through the evice TECNOLOGIC KEY0 with poles connector. This evice it s mainly useable for the serial programming of the instruments which nee to have the same parameters configuration or to keep a copy of the programming of an instrument an allow its rapi retransmission. To use the evice KEY0 it s necessary that the evice or instrument are being supplie. Instrument supplie an evice not supplie SUPPLY E Par. LS 2 HS 3 SE 4 CA ru P 7 Ft 8 9 t 0 t2 HC 2 i 3 n 4 E C L 7 Et 8 PS 9 20 o 2 A 22 Fb Description Minimum Set Point Maximum Set Point Probe Type Probe Calibration Unit of measurement Decimal point Measurement filter Differential Activation output for probe broken Deactivation output for probe broken Function moe output Defrosting interval (hrs) Defrosting interval (min) Lenght of efrost cycle Defrosting intervals Counting moe: rt = real ct = On Defrost isplay Lock: = isplay free on= Lock on temperature before efrost Lb= Lock on label F (uring efrosting) an P (uring post-efrosting) Differential isplay unlock after efrost Type of compressor protection: = elay at switch on 2= elay after switch 3= elay between starts Compressor protection Delay at power on Unlock isplay elay after efrost Function moe key DOWN: = No Function = /STAND-BY Range -8 HS LS 99 - nt C - F on - 20 sec H - C 24 hrs 9 min 99 min rt - ct on - - Lb hrs / Def nt 0.0 C on C 30 rt Note TECNOLOGIC - TLE 20 - OPERATING INSTRUCTIS - Vr. 0-09/0 - ISTR PAG. 4

5 23 24 PP Access Passwor to parameter functions Set Point 99 LS HS - PROBLEMS, MAINTENANCE AND GUARANTEE. - SIGNALLING Error Signalling: Error Reason E The probe may be -E interrupte or in short circuit, or may measure a value outsie the range allowe EE Internal memory error 0.0 Action Check the correct connection of the probe with the instrument an check the probe works correctly Check an if necessary re-programme the parameters function. In probe error status, the output behaves as set by the parameters t an t2. Other Signalling: Message Reason o Delay in switching on in progress F Defrosting in progress with L =Lb P Post-efrosting in progress with L =Lb.2 - CLEANING We recommen cleaning of the instrument with a slightly wet cloth using water an not abrasive cleaners or solvents which may amage the instrument..3 - GUARANTEE AND REPAIRS The instrument is uner warranty against manufacturing flaws or faulty material, that are foun within 2 months from elivery ate. The guarantee is limite to repairs or to the replacement of the instrument. The eventual opening of the housing, the violation of the instrument or the improper use an installation of the prouct will bring about the immeiate withrawal of the warranty s effects. In the event of a faulty instrument, either within the perio of warranty, or further to its expiry, please contact our sales epartment to obtain authorisation for sening the instrument to our company. The faulty prouct must be shippe to TECNOLOGIC with a etaile escription of the faults foun, without any fees or charge for Tecnologic, except in the event of alternative agreements. 7 - TECHNICAL DATA 7. - ELECTRICAL DATA Power supply: 2 VAC/VDC, VAC, 230 VAC +/- 0% Frequency AC: 0/0 Hz Power consumption: 3 VA approx. Input/s: input for temperature probes: PTC (KTY 8-2, C) or NTC (03AT-2, 2 C). Output/s: relay output DT (A-AC, A-AC3 20 VAC, HP 20VAC, /2HP 2 VAC). Electrical life for relay outputs: 0000 op. (om. VDE) Action type: type.b (EN 0730-) Overvoltage category: II Protection class : Class II Insulation: Reinforce insulation between the low voltage part (supply /230 V an relay output) an front panel; Reinforce insulation between the low voltage section (supply /230 V an relay output) an the extra low voltage section (inputs); Reinforce between supply an relay output; No insulation between supply 2 V an inputs MECHANICAL DATA Housing: Self-extinguishing plastic, UL 94 V0 Dimensions: 33 x 7 mm, epth 4 mm Weight: 0 g approx. Mounting: Flush in panel in 29 x 7 mm hole Connections: 2, mm 2 screw terminals block Degree of front panel protection : IP (NEMA 3S) mounte in panel with gasket Pollution situation: 2 Operating temperature: 0 T 0 C Operating humiity: < 9 RH% without conensation Storage temperature: -0 T +0 C 7.3 MECHANICAL DIMENSIS, PANEL CUT- AND MOUNTING [mm] 33 2 mm Out AL PANEL + GASKET MAX 2 mm 7 Def TLE SET 7 BRACKETS mm 4 RECOMMENDED PANEL CUT FUNCTIAL FEATURES Temperature Control: /OFF moe Defrost control: interval cycles by stopping compressor Measurement range: PTC: -0 T 0 C / -8 T 99 F; NTC: -0 T 09 C / -8 T 99 F Display resolution: or 0, (range ) Overall accuracy: +/- (0, % fs + igit) Sampling rate: 30 ms. Display:2 ½ Digit Re h 4 mm Software class an structure : Class A Compliance: ECC irective 2004/08/CE (EN022: class B; EN : 8KV air, 4KV cont.; EN : 0V/m; EN : 2KV supply, inputs, outputs; EN000-4-: supply 2KV com. moe, KV\ iff. moe; EN000-4-: 3V), 200/9/CE (EN 0730-, EN , EN ) 7. - INSTRUMENT ORDERING CODE TLE20 DS- = 230 VAC without KEY0 conn. TLE20 DSK = 230 VAC with KEY0 conn. TLE20 CS- = VAC without KEY0 conn. TLE20 CSK = VAC with KEY0 conn. TLE20 FS- = 2 VAC/VDC without KEY0 conn. TLE20 FSK = 2 VAC/VDC with KEY0 conn. TECNOLOGIC - TLE 20 - OPERATING INSTRUCTIS - Vr. 0-09/0 - ISTR PAG

TLZ10 DIGITAL ELECTRONIC THERMOCONTROLLER. toll-free 1(866) (603) ADVANCED THERMOELECTRIC PO Box 1003, WRJ, VT 05001

TLZ10 DIGITAL ELECTRONIC THERMOCONTROLLER. toll-free 1(866) (603) ADVANCED THERMOELECTRIC PO Box 1003, WRJ, VT 05001 TLZ0 DIGITAL ELECTRIC THERMOCTROLLER ADVANCED THERMOELECTRIC PO Box 003, WRJ, VT 000 toll-free (8) -434 (03) 888-47 sales@electracool.com The Z3 Series became the replacement for the TLZ0 and TDH-0 Series

More information

e30v DIGITAL ELECTRONIC THERMOMETER OPERATING INSTRUCTIONS Index

e30v DIGITAL ELECTRONIC THERMOMETER OPERATING INSTRUCTIONS Index e30v DIGITAL ELECTRONIC THERMOMETER OPERATING INSTRUCTIONS Vr. 01 (ENG) - 18/01 - cod.: ISTR-Me30V-ENG01 ASCON TECNOLOGIC S.rl. Viale Indipendenza 56, 27029 - VIGEVANO (PV) ITALY Tel.: +39 0381 69871 -

More information

INDEX ASCON TECNOLOGIC - Z31- OPERATING INSTRUCTIONS- Vr /12 - ISTR-MZ31-ENG02 - PAG. 1

INDEX ASCON TECNOLOGIC - Z31- OPERATING INSTRUCTIONS- Vr /12 - ISTR-MZ31-ENG02 - PAG. 1 FOREWORD Z3- Z3S DIGITAL ELECTRIC THERMO-CTROLLER OPERATING INSTRUCTIS ADVANCED THERMOELECTRIC PO Box 003, White River, VT 00 USA Toll-free: -8--434 (03) 888-247 sales@electracool.com User Manual Highlighted

More information

EWCH 485 Electronic Pulse Counter

EWCH 485 Electronic Pulse Counter Electronic Pulse Counter Technical Data Sheet INSTRUMENT DESCRIPTION GENERAL DESCRIPTION is a programmable microprocessor based counter with 1or 2 outputs. The instrument offers the possibility to program:

More information

TC 34 MICROPROCESSOR-BASED DIGITAL ELECTRONIC COUNTER

TC 34 MICROPROCESSOR-BASED DIGITAL ELECTRONIC COUNTER TC 34 MICROPROCESSOR-BASED DIGITAL ELECTRONIC COUNTER TECHNICAL DATA MECHANICAL DATA Housing Self-extinguishing plastic, UL 94 V0 Dimensions 33x75 mm depth 64 mm Weight 175 g approx. Connections 2,5 mm

More information

EWPC 901/A rel. 6/96 ing

EWPC 901/A rel. 6/96 ing EWPC 91A rel. 696 ing temperature controller with alarm output WHAT IT IS The EWPC 91A is a temperature controller specifically designed for refrigeration applications. The instrument includes a 1 Vdc

More information

e31 DIGITAL ELECTRONIC TEMPERATURE CONTROLLER WITH DEFROSTING FUNCTION OPERATING INSTRUCTIONS Index

e31 DIGITAL ELECTRONIC TEMPERATURE CONTROLLER WITH DEFROSTING FUNCTION OPERATING INSTRUCTIONS Index e31 DIGITAL ELECTRIC TEMPERATURE CTROLLER WITH DEFROSTING FUNCTI OPERATING INSTRUCTIS Vr 01 (ENG) - 17/06 - cod.: ISTR-Me31-ENG01 ASC TECNOLOGIC S.r.l. Viale Indipendenza 56, 27029 - VIGEVANO (PV) ITALY

More information

Indicator i 20. User manual

Indicator i 20. User manual Inicator i 20 WWW.PRECIAMOLEN.COM User manual 04-50-00-1 MU / 10/2012 Contents 1. Forewor... 5 Documentary conventions... 5 Pictograms... 5 Terminology an abbreviations... 5 Aitional ocumentation... 5

More information

E2EM-X4X1 2M *2 E2EM-X4X2 2M Shielded E2EM-X8X1 2M *2 E2EM-X8X2 2M *1 M30 15 mm E2EM-X15X1 2M *2 E2EM-X15X2 2M

E2EM-X4X1 2M *2 E2EM-X4X2 2M Shielded E2EM-X8X1 2M *2 E2EM-X8X2 2M *1 M30 15 mm E2EM-X15X1 2M *2 E2EM-X15X2 2M Long-istance Proximity Sensor EEM CSM_EEM_DS_E_7_ Long-istance Proximity Sensor Long-istance etection at up to mm enables secure mounting with reuce problems ue to workpiece collisions. No polarity for

More information

ELECTRONIC SCALE WB-380. Instruction manual

ELECTRONIC SCALE WB-380. Instruction manual ELECTRONIC SCALE WB-380 Instruction manual Temperature Range for Use : 5 C 35 C Relative Humiity : 30% 80% (without conensation) Temperature Range of Environment :

More information

CordEx. >> Operating instructions. English

CordEx. >> Operating instructions. English CorEx >> Operating instructions English Symbols use in this manual Important information concerning your safety is specifically marke. Follow these instructions closely to prevent accients an amage to

More information

A Universal Key for a fast and reliable Tecnologic s instruments. INSTRUCTIONS MANUAL Vr. 3.1 (GB) - cod.: A01-ENG

A Universal Key for a fast and reliable Tecnologic s instruments. INSTRUCTIONS MANUAL Vr. 3.1 (GB) - cod.: A01-ENG A - 01 Universal Key for a fast and reliable Tecnologic s instruments configuration. INSTRUCTIS MANUAL Vr. 3.1 (GB) - cod.: A01-ENG 1. INTRODUCTI The new key is able to operate with 4 different objects

More information

E2EM-X4X1 2M *2 E2EM-X4X2 2M Shielded E2EM-X8X1 2M *2 E2EM-X8X2 2M *1 M30 15 mm E2EM-X15X1 2M *2 E2EM-X15X2 2M

E2EM-X4X1 2M *2 E2EM-X4X2 2M Shielded E2EM-X8X1 2M *2 E2EM-X8X2 2M *1 M30 15 mm E2EM-X15X1 2M *2 E2EM-X15X2 2M Long-istance Proximity Sensor EEM CSM_EEM_DS_E Long-istance Proximity Sensor Long-istance etection at up to mm enables secure mounting with reuce problems ue to workpiece collisions. No polarity for easy

More information

Appearance Sensing distance Output configuration Operation mode Model. Appearance Sensing distance Output configuration Operation mode Model

Appearance Sensing distance Output configuration Operation mode Model. Appearance Sensing distance Output configuration Operation mode Model Spatter-resistant Proximity Sensor EEQ CSM_EEQ_DS_E Spatter-resistant Fluororesincoate Proximity Sensor Superior spatter resistance. Long Sensing-istance s ae for sensing istances up to mm. Pre-wire Smartclick

More information

Model Operation mode TL-W5MD1 2M *2 TL-W5MD2 2M *2 TL-W1R5MC1 2M *1 TL-W3MC1 2M. DC 3-wire, NPN TL-W5MC1 2M TL-W20ME1 2M *1 TL-W20ME2 2M *1

Model Operation mode TL-W5MD1 2M *2 TL-W5MD2 2M *2 TL-W1R5MC1 2M *1 TL-W3MC1 2M. DC 3-wire, NPN TL-W5MC1 2M TL-W20ME1 2M *1 TL-W20ME2 2M *1 Flat Inuctive CSM DS_E Stanar Flat s in Many Different Variations Only mm thick yet provies a sensing istance of mm (MC). ie-cast moels also available. Be sure to rea Safety Precautions on page 7. Orering

More information

E2EQ-X10D1-M1TGJ 0.3M

E2EQ-X10D1-M1TGJ 0.3M Spatter-resistant Proximity Sensor EEQ CSM_EEQ_DS_E_9_ Spatter-resistant Fluororesincoate Proximity Sensor Superior spatter resistance. Long Sensing-istance s ae for sensing istances up to mm. Pre-wire

More information

Appearance Sensing distance Output configuration Operation mode Model. Appearance Sensing distance Output configuration Operation mode Model

Appearance Sensing distance Output configuration Operation mode Model. Appearance Sensing distance Output configuration Operation mode Model Spatter-resistant Proximity Sensor EEQ CSM_EEQ_DS_E Spatter-resistant Fluororesincoate Proximity Sensor Superior spatter resistance. Long Sensing-istance s ae for sensing istances up to mm. DC -Wire s.

More information

Appearance Sensing distance Output configuration Operation mode Model NO E2EQ-X7D1 2M

Appearance Sensing distance Output configuration Operation mode Model NO E2EQ-X7D1 2M Spatter-resistant Proximity Sensor EEQ CSM_EEQ_DS_E Spatter-resistant Fluororesincoate Proximity Sensor Superior spatter resistance. Long Sensing-istance s ae for sensing istances up to mm. Pre-wire Smartclick

More information

F 10 DIGITAL ELECTRONIC TEMPERATURE CONTROLLER WITH DEFROSTING FUNCTION. Index. USER MANUAL - V1

F 10   DIGITAL ELECTRONIC TEMPERATURE CONTROLLER WITH DEFROSTING FUNCTION. Index. USER MANUAL - V1 WWW.OSAKASOLUTIS.COM DIGITAL ELECTRIC TEMPERATURE CTROLLER WITH DEFROSTING FUNCTI PREFACE F 10 USER MANUAL - V1 www.osakasolutions.com j This manual contains the information necessary for the m product

More information

EWPlus 961 EO Dispenser

EWPlus 961 EO Dispenser EWPlus 961 EO Dispenser Electronic controllers for refrigeration units NOTE: When the controller is powered on it performs a lamp test, during which time the display and LEDs will flash for several seconds

More information

4-step Chiller and Heat Pump Controller

4-step Chiller and Heat Pump Controller 4-step Chiller and Heat Pump Controller Technical Data Sheet GENERAL DESCRIPTION MODELS CODE MODEL DESCRIPTION MW324000 ECH 420 HEAT PUMP WITH 4 STEPS/ 2 CIRCUITS + MODBUS MW324005 ECH 420/V WITH SCREW

More information

ELECTRONIC PHYSICIAN SCALE WB-3000 INSTRUCTION MANUAL

ELECTRONIC PHYSICIAN SCALE WB-3000 INSTRUCTION MANUAL ELECTRONIC PHYSICIAN SCALE WB-3000 INSTRUCTION MANUAL Please keep this manual in a safe place, an make sure it is reaily available whenever necessary. Please use this prouct only after carefully reaing

More information

MiG2 CONTROLLERS. 2 & 4 Stage General Purpose Controllers, with Air-conditioning Facilities

MiG2 CONTROLLERS. 2 & 4 Stage General Purpose Controllers, with Air-conditioning Facilities MiG2 CONTROLLERS 2 & 4 Stage General Purpose Controllers, with Air-conditioning Facilities The MiG2 controllers incorporate: 2 Inputs (Configurable as Resistive, 0 10V, 0 20mA or 4 20mA) 2 or 4 Relay Outputs

More information

PRODUCT RANGE. GIS and Transformer Connectors

PRODUCT RANGE. GIS and Transformer Connectors PRODUCT RANGE GIS an Transformer Connectors 1 GIS an Transformer Connectors Connector Components The single-piece prefabricate Click-Fit fiel boy (II) connects the cable plug (III) to the socket (I) an

More information

I DT MC. Operating Manual SINAMICS S120. Verification of Performance Level e in accordance with EN ISO

I DT MC. Operating Manual SINAMICS S120. Verification of Performance Level e in accordance with EN ISO I DT MC Operating Manual SINAMICS S20 Verification of Performance Level e in accorance with EN ISO 3849- Document Project Status: release Organization: I DT MC Baseline:.2 Location: Erl. F80 Date: 24.09.2009

More information

CS 106 Winter 2016 Craig S. Kaplan. Module 01 Processing Recap. Topics

CS 106 Winter 2016 Craig S. Kaplan. Module 01 Processing Recap. Topics CS 106 Winter 2016 Craig S. Kaplan Moule 01 Processing Recap Topics The basic parts of speech in a Processing program Scope Review of syntax for classes an objects Reaings Your CS 105 notes Learning Processing,

More information

ECON-ZIP-BASE. ZIP Economizer Base Module

ECON-ZIP-BASE. ZIP Economizer Base Module ECON-ZIP-BASE ZIP Economizer Base Module You can mount the ZIP Economizer in any orientation; it is recommended that you mount it in a position that will allow full utilization of the LCD and key pad and

More information

Description TR D

Description TR D Description TR D 78385 270607 Electronic double thermostat with heat curve in a DIN standard bar enclosure 1. Short Description The electronic double thermostat serves to control electric heating panels

More information

ICB12, ICB18 and ICB30 4-wire DC DS ENG

ICB12, ICB18 and ICB30 4-wire DC DS ENG Proximity inuctive sensors with complementary output function escription enefits complete family. vailable in M12, M18 an M30 housings with an operating istance from 2 to 22 mm. Less machine owntime. Lower

More information

Operating instructions. Speed monitor D / / 2014

Operating instructions. Speed monitor D / / 2014 Operating instructions Speed monitor D200 80005257 / 00 05 / 2014 Contents 1 Preliminary note...4 1.1 Symbols used...4 1.2 Warning signs used...4 2 Safety instructions...5 2.1 General...5 2.2 Target group...5

More information

SOLARIMMERSION IV Advanced Installation Manual v1.9

SOLARIMMERSION IV Advanced Installation Manual v1.9 SOLARIMMERSION IV Advanced Installation Manual v1.9 1 Contents 1. Overview 2. Technical Specifications 3. Installation Mounting Electrical Installation Clamp Installation Wiring Diagrams 4. Installation

More information

FEMA ELECTRÓNICA. Series BDF. LARGE DISPLAYS for parallel BCD code. USER S MANUAL (HT r190307) BDF-xx-BCD for parallel BCD code

FEMA ELECTRÓNICA. Series BDF. LARGE DISPLAYS for parallel BCD code. USER S MANUAL (HT r190307) BDF-xx-BCD for parallel BCD code LARGE DISPLAYS BCD CODE Series BDF LARGE DISPLAYS for parallel BCD code BDF-xx-BCD for parallel BCD code FEMA ELECTRÓNICA IDEAL SOLUTION to display numerical values at long distances, controlled by parallel

More information

Technical data. Safety parameters: see page 333. DC maximum residual ripple: 10% Supply voltage tolerance: DC consumption: Control circuit

Technical data. Safety parameters: see page 333. DC maximum residual ripple: 10% Supply voltage tolerance: DC consumption: Control circuit Safety module CS DM-01 Technical data Housing PA 6.6 polyamide housing, self-extinguishing, V0 acc. to UL 94 Protection degree IP40 (housing), IP20 (terminal strip) Dimensions see page 283, design A Two-hand

More information

UNIVERSAL DIMMER DIM02SA/500U

UNIVERSAL DIMMER DIM02SA/500U Figure 1 : Dimmer module DIM02SA/500U 1. Product Description This module can function both Stand-Alone (so WITHOUT Controller, WITHOUT external power supply) but can also be connected to a Controller to

More information

Safety switches for hinged doors

Safety switches for hinged doors C Safety switches for hinged doors Selection diagram FR FM FX FZ FK 18 7 9 snap action overlapped CONTACT BLOCKS 21 NC 1NO+ CONDUIT ENTRIES Threaded conduit entries (standard) With cable gland assembled

More information

UNIVERSAL DIMMER DIM04SA/500U

UNIVERSAL DIMMER DIM04SA/500U overheating, overvoltage or short-circuit, the red ERROR-LED will be on. The output can be reset by putting it in the OFF-status. The DIM04SA/500U module also has 5 potential-free inputs to connect standard

More information

SEQUENCER FOR DEDUSTING PLANTS

SEQUENCER FOR DEDUSTING PLANTS BB SEQUENCER FOR DEDUSTING PLANTS PLEASE READ THE WHOLE USER MANUAL CAREFULLY BEFORE INSTALLING THE EQUIPMENT 1. ENTER DATAS IN SET MODE 1. Press key C to have access to the function menu F01 F13. 2. Press

More information

Products no longer available

Products no longer available echnical data sheet NV4-MF(-) Modulating linear actuator for -way and 3-way globe valves Actuating force 1000 N Nominal voltage AC/DC 4 V Modulating control DC 0... 10 V Position osition feedback feedbac

More information

ESM-3711-CL 77 x 35 DIN Size, Minimum & Maximum Temperature Record, Digital, ON / OFF Cooling Controller

ESM-3711-CL 77 x 35 DIN Size, Minimum & Maximum Temperature Record, Digital, ON / OFF Cooling Controller ESM-3711-CL 77x35 DIN Size Cooling Controller Internal Buzzer ESM-3711-CL 77 x 35 DIN Size, imum & imum Temperature Record, Digital, ON / OFF Cooling Controller - 3 Digits display - NTC input or, PTC input

More information

UNIVERSAL DIMMER DIM02SA/500U

UNIVERSAL DIMMER DIM02SA/500U Figure 1 : Dimmer module DIM02SA/500U 1. Product Description This module can function both Stand-Alone (so WITHOUT Controller, WITHOUT external power supply) but can also be connected to a Controller to

More information

Safety switches with manual mechanical delay and separate actuator

Safety switches with manual mechanical delay and separate actuator D Safety switches with manual mechanical delay and separate actuator Selection diagram VF KEYF VF KEYF1 VF KEYF VF KEYF VF KEYF7 VF KEYF ACTUATORS MECHANICAL DELAY C L L0 Short knob 0 sec. Short knob sec.

More information

INSTALLATION MANUAL. LC 200 Electronic Overload Guard. Software versione PW0501 R 0.3

INSTALLATION MANUAL. LC 200 Electronic Overload Guard. Software versione PW0501 R 0.3 INSTALLATION MANUAL LC 200 Electronic Overload Guard Software versione PW0501 R 0.3 CONTENTS MAIN FEATURES LC 200 TECHNICAL FEATURES Page 2 SYMBOLS Page 3 WARNINGS Page 3 IDENTIFICATION DATA PLATE Page

More information

EXPANSION PERIPHERAL CVM-R10 C. (Code ) INSTRUCTION MANUAL ( M / 00 A ) (c) CIRCUTOR S.A.

EXPANSION PERIPHERAL CVM-R10 C. (Code ) INSTRUCTION MANUAL ( M / 00 A ) (c) CIRCUTOR S.A. EXPANSION PERIPHERAL CVM-R10 C (Code 7 70 217 ) INSTRUCTION MANUAL ( M 981 170 / 00 A ) (c) CIRCUTOR S.A. ------ CVM-R10 C Peripheral --------------- Pag. 1 CVM-R10C EXPANSION PERIPHERAL 1.- DESCRIPTION

More information

Room Temperature Controllers

Room Temperature Controllers 3 021 Room Temperature Controllers for two-pipe fan coil units RCC10 Output for on / off valve actuator Outputs for three-speed fan Control depending on the room or return air temperature (RCC10) Automatic

More information

OEM. Room unit QAA822 with2- wire interface. Building Technologies CLIMATIX TM. For use with Climatix controllers

OEM. Room unit QAA822 with2- wire interface. Building Technologies CLIMATIX TM. For use with Climatix controllers OEM CLIMATIX TM Room unit QAA822 with2- wire interface For use with Climatix controllers Remote control of air conditioning unit Mandík Measurement of the room temperature Buttons for starting, setting

More information

InBin-P Pressure switches from 5 Pa Pa

InBin-P Pressure switches from 5 Pa Pa InBin-P Pressure switches from 5 Pa...100 Pa Electrical, binary pressure or differential pressure switches with adjustable switch activation delay 24 VAC/DC supply voltage, potential free switching contact

More information

AV24-MFT AV24-MFT2 AV24-MFT2-C105. Power consumption In operation For wire sizing N 1700 N Control Control signal Y Operating range

AV24-MFT AV24-MFT2 AV24-MFT2-C105. Power consumption In operation For wire sizing N 1700 N Control Control signal Y Operating range echnical data sheet AV4-MF()(-C105) Multi-functional linear actuators for -way and 3-way globe valves Actuating force 500 N Nominal voltage AC/DC 4 V Control: modulating DC 0 10 V Position feedback DC

More information

MVE5xx. Globe Valves Actuators POWER SUPPLY FORCE (N) MODEL DESCRIPTION APPLICATION AND USE OPERATION. long yoke, modulating/floating control

MVE5xx. Globe Valves Actuators POWER SUPPLY FORCE (N) MODEL DESCRIPTION APPLICATION AND USE OPERATION. long yoke, modulating/floating control Globe Valves Actuators MVE5xx MODEL FORCE (N) POWER SUPPLY DESCRIPTI MVE506 600 24VacVdc MVE510 1000 24VacVdc MVE515 1500 24VacVdc MVE506S 600 24VacVdc MVE510S 1000 24VacVdc MVE515S 1500 24VacVdc long

More information

USER MANUAL MULTI COLOR TOUCH SCREEN PAPERLESS RECORDER MODEL : ARC2020

USER MANUAL MULTI COLOR TOUCH SCREEN PAPERLESS RECORDER MODEL : ARC2020 USER MANUAL MULTI COLOR MODEL : ARC2020 ACCSYS ELECTRONICS 140/6B, GOLDEN INDUSTRIAL ESTATE, JAWAHARLAL NEHRU ROAD, GERUGAMBAKKAM, CHENNAI - 600122 Tel: 044 60505599 / 60505511 E-mail : sales@accsyselectronics.com

More information

Safety switches with separate actuator

Safety switches with separate actuator A Safety switches with separate actuator Selection diagram VF KEYF VF KEYF1 VF KEYF2 VF KEYF3 VF KEYF VF KEYF ACTUATORS CONTACT BLOCKS 9 snap action overlapped FD FP FL FC 21 22 33 3 3NC 2NO+1NC 1NO+ CONDUIT

More information

EMPlus 600. Electronic digital indicator

EMPlus 600. Electronic digital indicator EMPlus 600 EN Electronic digital indicator USER INTERFACE UP Press and release Scroll menu items Increases values DOWN Press and release Scroll menu items Decrease values KEYS EMPlus 600 STAND-BY (ESC)

More information

Study of Network Optimization Method Based on ACL

Study of Network Optimization Method Based on ACL Available online at www.scienceirect.com Proceia Engineering 5 (20) 3959 3963 Avance in Control Engineering an Information Science Stuy of Network Optimization Metho Base on ACL Liu Zhian * Department

More information

DAC 16 16BIT DIGITAL ANALOG CONVERTER

DAC 16 16BIT DIGITAL ANALOG CONVERTER DAC 16 16BIT DIGITAL ANALOG CONVERTER USER GUIDE Congratulations on your new CONSONANCE! Our proucts are base on a simple philosophy: The component shall reprouce the original musical soun, purely an naturally.

More information

ID 974 DCC electronic controllers for forced air refrigeration units

ID 974 DCC electronic controllers for forced air refrigeration units cod. 9IS42075 rel. 4/06 -GB- *If the conditions for defrosting are not present, or if parameter OdO0, the display will blink three times, to indicate that the operation will not be performed. ID 974

More information

Multi-Point Gas Detection and Control System

Multi-Point Gas Detection and Control System Multi-Point Gas Detection and Control System DESCRIPTION Wall mounted, microprocessor-based, multi-point, analog electronic control system for various gas, temperature and humidity detection, control and

More information

Manual of Electrical Installation for Pressure Probes KS and KS-SIL2 series

Manual of Electrical Installation for Pressure Probes KS and KS-SIL2 series Manual of Electrical Installation for Pressure Probes KS and KS-SIL2 series GEFRAN SAFETY GUARANTEE Code 8594A Edition 2/204 Contents. General precautions pag 2 2. Transmitters with amplified analog output

More information

RТTH DUAL ROOM SWITCH

RТTH DUAL ROOM SWITCH DUAL ROOM SWITCH FOR TEMPERATURE AND RELATIVE HUMIDITY Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS PRODUCT DESCRIPTION ARTICLE CODES INTENDED AREA OF USE TECHNICAL DATA

More information

InCos-P Pressure sensor 20 Pa Pa

InCos-P Pressure sensor 20 Pa Pa InCos-P Pressure sensor 20 Pa... 7.500 Pa Electrical pressure / differential pressure sensors 24 VAC/DC supply voltage, 0...10 V / (0) analogue Compact. Easy installation. Universal. Cost effective. Safe.

More information

ECON-ZIP-BASE. ZIP Economizer Base Unit. Wiring Diagram USA CANADA LATIN AMERICA / CARIBBEAN

ECON-ZIP-BASE. ZIP Economizer Base Unit. Wiring Diagram USA CANADA LATIN AMERICA / CARIBBEAN ECON-ZIP-BASE ZIP Economizer Base Unit 24 VAC ± 20%, 50/60 Hz; Class 2 power source 4 VA Base Control (ECON-ZIP-BASE) 5.5 VA Base Control with Energy Module (ECON-ZIP-BASE + ECON-ZIP-EM) Power Consumption

More information

USER MANUAL MULTI COLOR TOUCH SCREEN PAPERLESS RECORDER TPLR-96 Series

USER MANUAL MULTI COLOR TOUCH SCREEN PAPERLESS RECORDER TPLR-96 Series USER MANUAL MULTI COLOR TOUCH SCREEN PAPERLESS RECORDER TPLR-96 Series TEMPSEN DEVICES Plot No : 2&3, Balaji Nagar, 4 th Street, Mettukuppam, Thoraipakkam, Chennai-600097 Tele fax : +91-44-24581758,Mobil

More information

Zelio Control-modular measurement and control relays 1

Zelio Control-modular measurement and control relays 1 Presentation, description 1 106439 RM35 TM111MW Presentation Motor temperature measurement and 50MW and RM35 TM250MW monitor the following, on 3-phase supplies: correct sequencing of phases L1, L2 and

More information

2. Solenoid interlocks Description. Area of application. Design and way of functioning

2. Solenoid interlocks Description. Area of application. Design and way of functioning 2. Solenoi interlocks Description Area of application The solenoi interlocks of the AZM an MZM series have been esigne to prevent sliing, hinge an removable safety guars (fences, flaps or oors) from being

More information

Computer Organization

Computer Organization Computer Organization Douglas Comer Computer Science Department Purue University 250 N. University Street West Lafayette, IN 47907-2066 http://www.cs.purue.eu/people/comer Copyright 2006. All rights reserve.

More information

Control Cube T Digital Temperature Controller Operating Manual

Control Cube T Digital Temperature Controller Operating Manual Control Cube T Digital Temperature Controller Operating Manual Specifications Willhi WH7016+ digital thermostatic controller; 110vac; 30A relay Dual mode (heating or cooling) 13A maximum current rating

More information

Products no longer available

Products no longer available echnical data sheet NVF4-MF(-E)-R Modulating linear actuator with emergency function for -way and 3-way globe valves Actuating force 800 N Nominal voltage AC/DC 4 V Modulating control DC 0... 10 V Position

More information

XEC supercap (v. 1.0)

XEC supercap (v. 1.0) XEC supercap (v. 1.0) 1. Installation notes symbol alerts the user of important operating and maintenance (assistance) instructions found in the documentation attached to the device. This manual forms

More information

ICPlus 902. Electronic controller with 1 intervention point

ICPlus 902. Electronic controller with 1 intervention point ICPlus 902 EN Electronic controller with 1 intervention point USER INTERFACE UP Press and release Scroll menu items Increases values Press for at least 5 sec Function can be configured by the user (H31)

More information

Experion PKS R500 Migration Planning Guide

Experion PKS R500 Migration Planning Guide Experion PKS R500 Migration Planning Guie EPDOC-XX70-en-500E May 2018 Release 500 Document Release Issue Date EPDOC-XX70- en-500e 500 0 May 2018 Disclaimer This ocument contains Honeywell proprietary information.

More information

Energy Management Modular DC Energy analyzer Type VMU-E and VMU-X

Energy Management Modular DC Energy analyzer Type VMU-E and VMU-X Energy Management Modular DC Energy analyzer Type VMU-E and VMU-X Modular solution based on the combination of two units: VMU-E analysis unit and VMU-X universal power supply and RS485 communication unit.

More information

Dieter Wirth, Mess & Regeltechnik Neidlingen

Dieter Wirth, Mess & Regeltechnik Neidlingen Dieter Wirth, Mess & Regeltechnik Neidlingen Temperature controller Mod. BI50, BT31/32 and BI500, BT310/320/321 Made in Germany contents BT series 1. General Description... 2 2. Operating modes... 2 3.

More information

Multi-Point Gas Detection and Control System

Multi-Point Gas Detection and Control System Multi-Point Gas Detection and Control System Specifications subject to change without notice. USA 40804 Page of 7 DESCRIPTION Wall mounted, microprocessor-based, multi-point, analog electronic control

More information

Fast Route to Reliable Energy Savings ZIP Economizer

Fast Route to Reliable Energy Savings ZIP Economizer Fast Route to Reliable Energy Savings ZIP Economizer LCD Display Automotive quality, easy-to-read display allows easy verifi cation of set values and real time operating information Alarm Notification

More information

24 V DC typ. 0,65 W. Liquid level with conductive probes (type SK1, SK5) Resistance measurement E1-E0, E2-E0, E3-E0, E4-E0

24 V DC typ. 0,65 W. Liquid level with conductive probes (type SK1, SK5) Resistance measurement E1-E0, E2-E0, E3-E0, E4-E0 monitoring in conductive liquids 4 probe inputs for level monitoring Multifunction Adjustable sensor voltage Supply voltage 24-240V AC/DC Protective separation of measuring circuit 3 normally open contacts

More information

LOGIC CONTROLLER INSTALLATION MANUAL NTR 756 B /E

LOGIC CONTROLLER INSTALLATION MANUAL NTR 756 B /E LOGIC CONTROLLER INSTALLATION MANUAL NTR 756 B /E Table of contents 1. INTRODUCTION...1 2. HARDWARE DESCRIPTION...2 3. INSTALLATION...6 4. CONNECTION...8 5. USER SAFETY AND PROTECTION OF THE EQUIPMENT...11

More information

THERMOSTATS & CONTROLLERS

THERMOSTATS & CONTROLLERS DESCRIPTION The Belimo ZIP Economizer Series saves energy in buildings by using cool outside air as a means of cooling the indoor space. This application can drastically reduce HVAC energy costs while

More information

JUMO itron 04/08/16/32 Compact microprocessor controllers

JUMO itron 04/08/16/32 Compact microprocessor controllers JUMO GmbH & Co. KG Delivery address:mackenrodtstraße 14, 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 e-mail: mail@jumo.net Internet: www.jumo.net

More information

Operating instructions. Switching amplifier DN0210 DN / / 2015

Operating instructions. Switching amplifier DN0210 DN / / 2015 Operating instructions Switching amplifier DN0210 DN0220 UK 80011079 / 00 01 / 2015 Contents 1 Preliminary note...4 1.1 Symbols used...4 1.2 Warning signs used...4 2 Safety instructions...5 2.1 General...5

More information

EVF305 Product specifications - Version 1.02 EVCO S.p.A. Evco S.p.A. Product specifications EVF305

EVF305 Product specifications - Version 1.02 EVCO S.p.A. Evco S.p.A. Product specifications EVF305 Evco S.p.A. Product specifications EVF305 Digital controllers for the management of the rotisserie with capacitive type user interface Drawn-up by Name and surname Date November 2012 page 1 of 14 1. REVISIONS

More information

Solid-state Timer. Ordering Information. Miniature Timer with Multiple Time Ranges and Multiple Operating Modes H3YN- - Accessories (Order Separately)

Solid-state Timer. Ordering Information. Miniature Timer with Multiple Time Ranges and Multiple Operating Modes H3YN- - Accessories (Order Separately) Solid-state Timer Miniature Timer with Multiple Time Ranges and Multiple Operating Modes Minimizes stock. Pin configuration compatible with MY Power Relay. Standard multiple operating modes and multiple

More information

1. Short description. 2. Features. 3. Technical parameters

1. Short description. 2. Features. 3. Technical parameters 1. Short description TCW122B-RR is a remote relay control module with embedded WEB server for set up. The device has two digital inputs and two relays, with normally open and normally closed contacts.

More information

Technical data. Dimensions: see page 116. ): 4 kv Rated insulation voltage (U i Over-voltage category: Power supply. Rated operating voltage (Un):

Technical data. Dimensions: see page 116. ): 4 kv Rated insulation voltage (U i Over-voltage category: Power supply. Rated operating voltage (Un): Safety module CS AR-91, according to EN 81 Safety modules for the lift automatic floor levelling operation according to EN 81 Main functions For safety applications up to SIL 3 / PL e Choice between automatic

More information

English. Operating manual. Universal transmitter UT125. Save for later reference. Companies / brands of GHM

English. Operating manual. Universal transmitter UT125.  Save for later reference. Companies / brands of GHM English Operating manual Universal transmitter UT125 Companies / brands of GHM www.ghm-messtechnik.de Save for later reference. Table of contents page 1. Intended use (areas of application)... 3 1.1 Safety

More information

User s Guide. 600A AC Clamp Meter. Model 38387

User s Guide. 600A AC Clamp Meter. Model 38387 User s Guide 600A AC Clamp Meter Model 38387 Safety International Safety Symbols This symbol, adjacent to another symbol or terminal, indicates the user must refer to the manual for further information.

More information

User Guide Automatic Transfer Switch (ATS)

User Guide Automatic Transfer Switch (ATS) User Guide Automatic Transfer Switch (ATS) V.1.0 Table of Contents 1. Introduction... 2 2. Product Overview... 2 3. Important Safety Warnings... 3 4. Operation Indicators & Status... 3 5. Installation...

More information

MVE5xxR. Globe Valves Actuators with Emergency Fail Safe Function DESCRIPTION POWER SUPPLY [N] APPLICATION AND USE OPERATION

MVE5xxR. Globe Valves Actuators with Emergency Fail Safe Function DESCRIPTION POWER SUPPLY [N] APPLICATION AND USE OPERATION Globe Valves Actuators with Emergency Fail Safe Function MVE5xxR MODEL FORCE [N] POWER SUPPLY DESCRIPTION MVE506R 600 24Vac/dc MVE506SR 600 24Vac/dc long yoke, modulating/ floating control with position

More information

Actuator ABNM A5 LOG/LIN for AB-QM, 0-10 V Proportional

Actuator ABNM A5 LOG/LIN for AB-QM, 0-10 V Proportional Actuator ABNM A5 LOG/LIN for AB-QM, 0-10 V Proportional Application Plug-in halogen free cable Simple snap-on installation IP54 in any installation position First-Open function (NC versions) Compact size,

More information

100% electricity. Automatic transfer switch controllers ATL series

100% electricity. Automatic transfer switch controllers ATL series 100% electricity Automatic transfer switch controllers ATL series Automatic transfer switch controllers Keep control around the clock General characteristics Rated auxiliary power supply: 220-230-240VAC

More information

Coupling the User Interfaces of a Multiuser Program

Coupling the User Interfaces of a Multiuser Program Coupling the User Interfaces of a Multiuser Program PRASUN DEWAN University of North Carolina at Chapel Hill RAJIV CHOUDHARY Intel Corporation We have evelope a new moel for coupling the user-interfaces

More information

SRQ24A. Technical data. Safety notes. Rotary actuator for ball valves Torque 16Nm Nominal voltage AC/DC 24V Control: Open-close Running time 9s

SRQ24A. Technical data. Safety notes. Rotary actuator for ball valves Torque 16Nm Nominal voltage AC/DC 24V Control: Open-close Running time 9s SRQ24A Rotary actuator for ball valves orque 16Nm Nominal voltage AC/DC 24V Control: Open-close Running time 9s echnical data Electrical data Nominal voltage AC 24V, 50/60Hz / DC 24V Nominal voltage range

More information

Carbon Monoxide (CO) Gas Detection and Control System

Carbon Monoxide (CO) Gas Detection and Control System Carbon Monoxide (CO) Gas Detection and Control System DESCRIPTION Gas monitor with built-in carbon monoxide (CO) sensor, wall-mounted, accepts inputs from remote devices such as other gas sensors, temperature

More information

ENGLISH. User manual.

ENGLISH. User manual. ENGLISH User manual Copyright HT ITALIA 2012 Release EN 2.00-18/12/2012 Table of contents: 1. PRECAUTIONS AND SAFETY MEASURES... 2 1.1. Preliminary instructions... 2 1.2. During use... 3 1.3. After use...

More information

User's Guide. Extech AM A AC Analog Clamp Meter

User's Guide. Extech AM A AC Analog Clamp Meter User's Guide Extech AM300 300A AC Analog Clamp Meter Introduction Congratulations on your purchase of the Extech AM300 Analog Clamp Meter. This device measure AC Voltage and Current, DC Voltage, and Resistance.

More information

Room Temperature Controller

Room Temperature Controller 3 023 Room Temperature Controller for four-pipe fan coil units RCC30 Outputs for on / off valve actuators Outputs for three-speed fan Control depending on room or return air temperature Operating modes:

More information

02/11/2015

02/11/2015 DIN Rail Mount 22.5 mm ETM2 Part number 84874023 Version ETM : Controls temperature of machines using built-in PTC probes Line break or probe short-circuit detection Version ETM2 / ETM22 : Fault latching

More information

Product and Applications Description. Example of Operation. Installation Instructions WARNING. Note. Application Programs

Product and Applications Description. Example of Operation. Installation Instructions WARNING. Note. Application Programs Product and Applications Description Example of Operation dimmer UP 525/11 load circuit AC 230 V L1 N The dimmer UP 525/11 is a dimming actuator for mounting in box mounts (a.o. 60 mm Ø, 60 mm depth).

More information

ATS22D75S6U. Main. Range of product Altistart 22. Component name. Factory setting current. Utilisation category. IP degree of protection

ATS22D75S6U. Main. Range of product Altistart 22. Component name. Factory setting current. Utilisation category. IP degree of protection Product datasheet Characteristics ATS22D75S6U Complementary Assembly style Function available Supply voltage limits Main Range of product Altistart 22 Product or component type Product destination Product

More information

Voltage Current Front-mounting bracket

Voltage Current Front-mounting bracket Switching Power Supply S8PS Compact DIN-Rail Mounting Industrial Power Supplies with Capacities Up to 600 W Models range from 0 W to 600 W. Universal input: voltage range 0 to 240 VAC. Power Factor Correction

More information

MINI MCR-SL-PT100-UI-200

MINI MCR-SL-PT100-UI-200 Configurable temperature transducer for PT00 INTERFACE Data sheet 078_en_0 PHOENIX CONTACT 00-0-5 Description The MINI MCR-SL-PT00-UI-00... is a configurable -way isolated temperature transducer. It is

More information

Power consumption In operation At rest For wire sizing. Torque Inhibiting torque. 150 s / C Sound power level Motor

Power consumption In operation At rest For wire sizing. Torque Inhibiting torque. 150 s / C Sound power level Motor echnical data sheet GK4A- Damper actuator with capacitor technology for adjusting air dampers with emergency control function and extended functionalities in ventilation and airconditioning systems for

More information

Product and functional description. Application Program. instabus EIB Technical product information. April (6 x AC 230 V / 0,05 A)

Product and functional description. Application Program. instabus EIB Technical product information. April (6 x AC 230 V / 0,05 A) Product and functional description also functions if the bus cable is not connected or if the bus communication fails. After a long push button action (> 2 s), the other valve group is selected. The yellow

More information