FUJITSU Server PRIMERGY CX400 M4 Server Enclosure

Size: px
Start display at page:

Download "FUJITSU Server PRIMERGY CX400 M4 Server Enclosure"

Transcription

1 Operating Manual - English FUJITSU Server PRIMERGY CX400 M4 Server Enclosure Operating Manual July 2017

2 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps us optimize our documentation to suit your individual needs. Feel free to send us your comments by to Certified documentation according to DIN EN ISO 9001:2008 To ensure a consistently high quality standard and user-friendliness, this documentation was created to meet the regulations of a quality management system which complies with the requirements of the standard DIN EN ISO 9001:2008. cognitas. Gesellschaft für Technik-Dokumentation mbh Copyright and Trademarks Copyright 2017 FUJITSU LIMITED All rights reserved. Delivery subject to availability; right of technical modifications reserved. All hardware and software names used are trademarks of their respective manufacturers. The contents of this manual may be revised without prior notice. Fujitsu assumes no liability for damages to third party copyrights or other rights arising from the use of any information in this manual. No part of this manual may be reproduced in any form without the prior written permission of Fujitsu. Microsoft, Windows, Windows Server, and Hyper-V are trademarks or registered trademarks of Microsoft Corporation in the USA and other countries. Intel and Xeon are trademarks or registered trademarks of Intel Corporation or its subsidiaries in the USA and other countries.

3 Before reading this manual For your safety This manual contains important information for safely and correctly using this product. Carefully read the manual before using this product. Pay particular attention to the accompanying manual "Safety Notes and Regulations" and ensure these safety notes are understood before using the product. Keep this manual and the manual "Safety Notes and Regulations" in a safe place for easy reference while using this product. Radio interference This product is a "Class A" ITE (Information Technology Equipment). In a domestic environment this product may cause radio interference, in which case the user may be required to take appropriate measures. VCCI-A Aluminum electrolytic capacitors The aluminum electrolytic capacitors used in the product's printed circuit board assemblies and in the mouse and keyboard are limited-life components. Use of these components beyond their operating life may result in electrolyte leakage or depletion, potentially causing emission of foul odor or smoke. As a guideline, in a normal office environment (25 C) operating life is not expected to be reached within the maintenance support period (5 years). However, operating life may be reached more quickly if, for example, the product is used in a hot environment. The customer shall bear the cost of replacing replaceable components which have exceeded their operating life. Note that these are only guidelines, and do not constitute a guarantee of trouble-free operation during the maintenance support period. High safety use This product has been designed and manufactured to be used in commercial and/or industrial areas as a server. When used as visual display workplace, it must not be placed in the direct field of view to avoid incommoding reflections (applies only to TX server systems). The device has not been designed or manufactured for uses which demand an extremely high level of safety and carry a direct and serious risk of life or body if such safety cannot be assured. CX400 M4 Operating Manual

4 These uses include control of nuclear reactions in nuclear power plants, automatic airplane flight control, air traffic control, traffic control in mass transport systems, medical devices for life support, and missile guidance control in weapons systems (hereafter, "high safety use"). Customers should not use this product for high safety use unless measures are in place for ensuring the level of safety demanded of such use. Please consult the sales staff of Fujitsu if intending to use this product for high safety use. Measures against momentary voltage drop This product may be affected by a momentary voltage drop in the power supply caused by lightning. To prevent a momentary voltage drop, use of an AC uninterruptible power supply is recommended. (This notice follows the guidelines of Voltage Dip Immunity of Personal Computer issued by JEITA, the Japan Electronics and Information Technology Industries Association.) Technology controlled by the Foreign Exchange and Foreign Trade Control Law of Japan Documents produced by Fujitsu may contain technology controlled by the Foreign Exchange and Foreign Trade Control Law of Japan. Documents which contain such technology should not be exported from Japan or transferred to non-residents of Japan without first obtaining authorization in accordance with the above law. Harmonic Current Standards This product conforms to harmonic current standard JIS C Only for Japan: About SATA HDDs The SATA version of this server supports HDDs with SATA/BC-SATA storage interfaces. Please note that the usage and operation conditions differ depending on the type of HDD used. Please refer to the following internet address for further information on the usage and operation conditions of each available type of HDD: Operating Manual CX400 M4

5 Contents 1 Introduction Concept and target groups for this manual Documentation overview Notational conventions Functional overview Features Server enclosure specification Installation steps, overview Important information Safety instructions ENERGY STAR CE conformity FCC Class A Compliance Statement Environmental protection Transporting the server enclosure Notes on installing the server enclosure in the rack Hardware installation Unpacking the server enclosure Installing/removing the server enclosure in/from the rack Mounting the server enclosure in the rack Removing the server enclosure out of the rack CX400 M4 Operating Manual

6 Contents 5.3 Connecting the server enclosure to the mains Notes on connecting/disconnecting cables Starting up and operation Overview of the server enclosure Front overview with CX2550 M4 server nodes Front overview with CX2560 M4 / CX2570 M4 server nodes Rear overview with CX2550 M4 or CX2560 M4 server nodes Rear overview with CX2570 M4 server nodes Controls and indicators Front of the server enclosure Indicators on the front panel (enclosure-related) Indicators on the front panel (node-related) ID card Indicators on the HDDs Indicator on hot-plug PSU Indicators of the server nodes Switching the multi-node server system on and off Cleaning the server enclosure Property and data protection BIOS setup security functions Troubleshooting and tips Power-on indicator remains unlit Drives reported as dead when starting system Added drive reported as defective Operating Manual CX400 M4

7 1 Introduction The FUJITSU Server PRIMERGY CX scale-out systems are the ideal basis for cloud, hyper-converged and high performance computing solutions. They provide data centers as well as branch offices with massive computing power for virtualized environments, complex calculations as well as consolidation and high-availabilty scenarios. The FUJITSU Server PRIMERGY CX400 M4 helps to meet the immense challenges now facing companies as well as research and development institutions. The system with only 2 height units contains up to four server nodes, 8 Intel Xeon Processors and 64 DDR4 memory DIMMs, thus providing the very highest performance and energy efficiency levels. The scale-out system can be perfectly adapted for a wide range of applications thanks to its high degree of modularity. When requirements change, additional server nodes, co-processor cards or hard disks can just be added. In comparison to conventional rack servers the PRIMERGY CX400 M4 wins through thanks to its double server density and low hardware and operating costs. The system is thus an ideal replicable component in order to implement large scale-out solutions. 1.1 Concept and target groups for this manual This operating manual describes how to install, set up and operate your server enclosure. This operating manual is intended for those responsible for installing the hardware and ensuring that the system runs smoothly. It contains all the information you need to put your PRIMERGY CX400 M4 server enclosure into operation. To understand the various expansion options, you will need to be familiar with the fields of hardware and data transmission and you will require a basic knowledge of the underlying operating system. CX400 M4 Operating Manual 7

8 Introduction 1.2 Documentation overview More information on your PRIMERGY CX400 M4 server enclosure can be found in the following documents: "Quick Start Hardware - PRIMERGY CX400 M4 Server Enclosure" "ServerView Suite Quick Start Guide" "Safety Notes and Regulations" manual " 安全上のご注意 " for Japan "Warranty" manual " 保証書 " for Japan "Returning used devices" manual and "Service Desk" leaflet " サポート & サービス " for Japan "FUJITSU Server PRIMERGY CX400 M4 Server Enclosure Upgrade and Maintenance Manual" Further information The PRIMERGY CX400 M4 server enclosure is a multi-node system. For information on the individual server nodes please refer to the following manuals: "FUJITSU Server PRIMERGY CX2550 M4 / CX2560 M4 / CX2570 M4 Server Node Operating Manual" "D385x BIOS Setup Utility for FUJITSU Server PRIMERGY CX2550 M4 / CX2560 M4 / CX2570 M4" Reference Manual "FUJITSU Server PRIMERGY CX2550 M4 / CX2560 M4 / CX2570 M4 Server Node Upgrade and Maintenance manual" I All documentation on PRIMERGY hardware and ServerView software is available online from the Fujitsu manuals server at: For Japan: The complete PRIMERGY documentation set can also be downloaded as a DVD ISO image at: ftp://ftp.ts.fujitsu.com/images/serverview/manuals For Japan: 8 Operating Manual CX400 M4

9 Introduction Further sources of information: ServerView Suite Glossary Manual for the monitor Documentation for the boards and drives Operating system documentation Information files in your operating system 1.3 Notational conventions The following notational conventions are used in this manual: Text in italics "Quotation marks" V CAUTION! I indicates commands or menu items. indicate names of chapters and terms that are being emphasized. describes activities that must be performed in the order shown. pay particular attention to texts marked with this symbol. Failure to observe this warning may endanger your life, destroy the system or lead to the loss of data. indicates additional information, notes and tips. CX400 M4 Operating Manual 9

10 Introduction 10 Operating Manual CX400 M4

11 2 Functional overview 2.1 Features This section provides information on the features and technical data of the PRIMERGY CX400 M4 server enclosure. For information on key characteristics and layout of the system board, see the "FUJITSU Server PRIMERGY CX400 M4 Server Enclosure Upgrade and Maintenance Manual". Server enclosure The PRIMERGY CX400 M4 server enclosure consists of the server enclosure which has to be equipped with different configurations of server nodes, as there are: 4 PRIMERGY CX2550 M4 / CX2560 M4 server nodes 2 PRIMERGY CX2570 M4 server nodes All server nodes are hot pluggable. A mixture of CX2550 M4 and CX2560 M4 / CX2570 M4 nodes within the same server enclosure is not supported. HDDs Using CX2550 M4 server nodes, the server enclosure can be equipped with a maximum of 8 x 2.5 " HDD / SSD modules. Using CX2560 M4 server nodes, the server enclosure can be equipped with a maximum of 24x 2.5 " HDD / SSD modules. Using CX2570 M4 server nodes, the server enclosure can be equipped with a maximum of 12x 2.5 " HDD / SSD modules. Each HDD/SSD module can accommodate an SAS/SATA HDD or SSD with a maximum height of 1 inch. The module is connected to the SAS/SATA backplane wirelessly. This allows HDD / SSD modules to be plugged in or pulled out easily. Six SATA HDD/SSDs can be controlled by the onboard SATA controller. To control further SAS/SATA HDD/SSDs, an additional SAS/RAID controller must be installed. Hybrid configurations of SAS HDDs, SATA HDDs, SAS SSDs and SATA SSDs within the same logical drive (RAID array) are not supported. CX400 M4 Operating Manual 11

12 Functional overview If the server enclosure has the corresponding RAID configuration, HDD / SSD modules can also be replaced during operation. Power supply The system has two bays for hot-plug PSUs. Each hot-plug PSU can be replaced during operation (see the "FUJITSU Server PRIMERGY CX400 M4 Server Enclosure Upgrade and Maintenance Manual"). The PSUs adjust automatically to any mains voltage in the range 100 V V. High level of availability and data security When memory data is accessed, 1-bit errors are identified in the main memory and automatically corrected with the error correcting code (ECC) method. ASR&R (Automatic Server Reconfiguration and Restart) restarts the system in the event of an error and automatically "hides" the defective system components. A RAID controller supports different RAID levels and increase the availability and data security of the system. The hot-plug HDD modules provide additional availability. Advanced Thermal Design The Advanced Thermal Design option allows you to operate the system with a wider temperature range of 5 C to 40 C, depending on your system and configuration. This option can only be ordered from the manufacturer and is indicated by the respective logo on the identification rating plate. V CAUTION In a system that is configured with Advanced Thermal Design, only certain components which support the respectively increased higher operating temperature range may be installed and used. For applicable restrictions, please refer to the official configurator tool. 12 Operating Manual CX400 M4

13 Functional overview 2.2 Server enclosure specification This section explains the specifications for the server enclosure. The specifications for this server enclosure are liable to be updated without any notice. Please be forewarned. System board Server enclosure type Rear bays Fan configuration Power supply configuration 2U chassis for 19-inch rack 4 bays for half wide server nodes and 2 bays for PSU 8 hot-pluggable fans 2x hot-plug PSUs Operating panel Operating buttons On/off button ID indicator Dimensions / weight Server enclosure (W x D x H) Mounting depth server enclosure Height server enclosure Body (444.0 x x 86.5 mm)/ Bezel (480.2 x x 86.5 mm) mm 2 U 19" rackmount Yes Mounting cable depth 200 mm (1000 mm server enclosure recommended) server enclosure Weight up to 45 kg plus 4 kg for rack rails Weight notes actual weight may vary depending on configuration Rack mounting kit Included in Rack System CX400 M4 Operating Manual 13

14 Functional overview Electrical data (hot-plug PSU 1600 W) Rated voltage range V Frequency 50 Hz - 60 Hz Max. rated current 10.5 A ( V) / 9.2 A ( V) Output 900 W ( V) / 1600 W ( V) Main power fuse 16 A Protection class I Power supply efficiency 94% (at 50% load) Electrical value notes Active power max. value depends on system configuration. For details see "Power Configuration Tool" or "System Architect" Electrical data (hot-plug PSU 2400 W) Rated voltage range V Frequency 50 Hz - 60 Hz Rated current 14 A ( V) / 13 A ( V) Output 1200 W ( V) / 2400 W ( V) Main power fuse 16 A Protection class I Power supply efficiency 94% (at 50% load) Electrical value notes Active power max. value depends on system configuration. For details see "Power Configuration Tool" or "System Architect" 14 Operating Manual CX400 M4

15 Functional overview Ambient conditions Environment class 3K2 Environment class 2K2 Temperature: Operation (3K2) EN / IEC 721 Part 3-3 EN / IEC 721 Part C ~ 40 C (with ATD) 10 C ~ 35 C (without ATD) The maximum temperature depends on type of the CPU. Transport (2K2) -25 C ~ +60 C Humidity 10% ~ 85% (non condensing) Condensation during operation must be avoided! Noise level Sound power level L WAd (ISO 9296) Sound pressure level at adjacent position L pam (ISO 9296) < 7.8 B (standby) < 8.6 B (operation) < 62.3 db(a) (standby) < 70 db(a) (operation) Drive bays Product Model Name CX2550/60 M4 CX2570 M4 Product Type Dual Socket Server Node (Intel) Dual Socket Server Node (Intel) CPU Quantity Support 2 2 Number of nodes (max.) 4 2 Memory slots total Supported capacity RAM (max.) 2048 GB 2048 GB CX400 M4 Operating Manual 15

16 Functional overview Number of storage drives (max.) 2 x 2.5-inch 6 x 2.5-inch (applicable to CX2550) or 6 x 2.5-inch (applicable to CX2560) Co-processor cards up to 2 up to 2 or up to 4 SXM2 modules 16 Operating Manual CX400 M4

17 Functional overview Compliance with standards Product safety and ergonomics International IEC Europe Safety EN EN EN Ergonomics ISO EN EK1-ITB 2003:2007 USA / Canada CSA-C22.2 No ed. UL ed. Taiwan CNS China GB 4943 Australia, New Zealand (RCM) CB(IEC AS/NZS Deviations.) Saudi Arabia (SASO) CB (IEC ) Kenia (KEBS) KS (Kenya Standards) CB(IEC ) Kuwait (KUKAS) KSS (Kuwaiti Standards Specifications) CB(IEC ) Tanzania (TBS) CB(IEC ) Russia (EAC) CU TR 004/2011 (IEC :2005) Electromagnetic compatibility International CISPR 22 Europe EN Class A EN EN EN ETSI USA / Canada 47CFR part 15 Class A / ICES-003 Taiwan CNS Class A China GB 9245 / GB Australia, New Zealand (RCM) AS/NZS CISPR 32 CX400 M4 Operating Manual 17

18 Functional overview Russia (EAC) CU TR 020/2011 (CISPR22) Japan VCCI Class A / JEITA Korea KN 32 / KN 35 CE marking to EU directives RoHS Compliance EU EN RoHS Compliance Taiwan CNS Low Voltage Directive 2006/95/EC Electromagnetic compatibility 2004/108/EC V CAUTION! This device meets the requirements of Class A CISPR 22. This device can cause radio interference in residential areas. Numbering scheme CX2550 CX2560/CX2570 PSU2 PSU1 Slot 4 Slot 2 Slot 3 Slot 1 PSU2 PSU1 Slot 4 Slot 2 Slot 3 Slot 1 PSU2 PSU1 Slot 3 Slot 1 PSU2 PSU1 PSU2 PSU1 Slot 3 Slot 4 Slot 3 Slot 2 Slot 1 Slot 1 Figure 1: Numbering scheme for CX2550 M4 / CX2560 M4 / CX2570 M4 The numbers are referred to on the front of the server enclosure to identify the corresponding operating panels (see section "Front overview with CX2550 M4 server nodes" on page 53). 18 Operating Manual CX400 M4

19 3 Installation steps, overview This chapter contains an overview of the steps necessary to install your server enclosure. Links take you to sections where you can find more detailed information about the respective steps: First of all, carefully read the safety instructions in Chapter "Important information" on page 21. Transport the server enclosure to the place where you want to set it up. Unpack the system, check the contents of the package for visible transport damage and check whether the items delivered match the details on the delivery note (see section "Unpacking the server enclosure" on page 36). Make sure that you have all necessary manuals (see section "Documentation overview" on page 8); print out the PDF files if required. Components that have been ordered additionally may be delivered loose with the server enclosure. For mounting refer to the original component documentation. Mount the server enclosure into the rack (see section "Installing/removing the server enclosure in/from the rack" on page 37). Wire the server enclosure. Follow the instructions in section "Notes on connecting/disconnecting cables" on page 51. Connect the server enclosure to the mains (see section "Connecting the server enclosure to the mains" on page 50). Familiarize yourself with the controls and indicators on the front and rear of the server enclosure (see section "Controls and indicators" on page 57). CX400 M4 Operating Manual 19

20 Installation steps, overview Configure the server enclosure and install the desired operating system and applications. The following options are available: Remote installation with the ServerView Installation Manager: With the ServerView Suite DVD provided, you can configure the server enclosure and install the operating system in a convenient manner. Details on how to operate the ServerView Installation Manager, as well as some additional information, are included in the "ServerView Suite Installation Manager" user s guide (on the Fujitsu manuals server under x86 Servers - Software - ServerView Suite - Server Installation and Deployment). Configuration information can also be found in the Operating Manual of the installed server node. Local configuration and installation with or without the ServerView Installation Manager (for further details see Operating Manual of the installed server node). I You will find more information on installing the server enclosure remotely or locally in the "ServerView Suite Installation Manager" user s guide (on the Fujitsu manuals server under x86 Servers - Software - ServerView Suite - Server Installation and Deployment). 20 Operating Manual CX400 M4

21 4 Important information In this chapter you will find essential information regarding safety when working on your server enclosure. I Depending on your server enclosure or the installed options some information is not valid for your server enclosure. V CAUTION! Before installing and starting up a server enclosure, please observe the safety instructions listed in the following section. This will help you to avoid making serious errors that could impair your health, damage the server enclosure and endanger the data base. 4.1 Safety instructions I The following safety instructions are also provided in the manual "Safety Notes and Regulations" or " 安全上のご注意 ". This server enclosure meets the relevant safety regulations for IT equipment. If you have any questions about whether you can install the server enclosure in the intended environment, please contact your sales outlet or our customer service team. The actions described in this manual shall be performed by technical specialists. A technical specialist is a person who is trained to install the server enclosure including hardware and software. Repairs to the server enclosure that do not relate to CSS failures shall be performed by service personnel. Please note that unauthorized interference with the server enclosure will void the warranty and exempt the manufacturer from all liability. Any failure to observe the guidelines in this manual, and any improper repairs could expose the user to risks (electric shock, energy hazards, fire hazards) or damage the equipment. Only valid for non hot-plug components Before installing/removing internal components to/from the server enclosure, turn off the server enclosure, all peripheral devices, and any other connected devices. Also unplug all power cords from the power outlet. Failure to do so can cause electric shock or damage. CX400 M4 Operating Manual 21

22 Important information Before starting up During installation and before operating the server enclosure, observe the instructions on environmental conditions for your server enclosure. If the server enclosure is brought in from a cold environment, condensation may form both inside and on the outside of the server enclosure. Wait until the server enclosure has acclimatized to room temperature and is absolutely dry before starting it up. Material damage may be caused to the server enclosure if this requirement is not observed. Only transport the server enclosure in its original packaging or in packaging that protects it from impacts and jolts. In Japan and APAC, transporting the server enclosure in its original packaging does not apply. Installation and operation This server enclosure should not be operated in ambient temperatures above 35 C. For server enclosures with Advanced Thermal Design the ambient temperature can increase to 40 C or 45 C. If the server enclosure is integrated into an installation that draws power from an industrial power supply network with an IEC309 connector, the power supply's fuse protection must comply with the requirements for nonindustrial power supply networks for type A connectors. The server enclosure automatically adjusts itself to a mains voltage, see the type label of your server enclosure. Ensure that the local mains voltage lies within these limits. This server enclosure must only be connected to properly grounded power outlets or connected to the grounded rack internal power distribution server enclosure with tested and approved power cords. Ensure that the server enclosure is connected to a properly grounded power outlet close to the server enclosure. Ensure that the power sockets on the server enclosure and the properly grounded power outlets are easily accessible. The On/Off button or the main power switch (if present) does not isolate the server enclosure from the mains power supply. In case of repair or servicing disconnect the server enclosure completely from the mains power supply, unplug all power plugs from the properly grounded power outlets. 22 Operating Manual CX400 M4

23 Important information Always connect the server enclosure and the attached peripheral devices to the same power circuit. Otherwise you run the risk of losing data if, for example, the server enclosure is still running but a peripheral device (e.g. memory subsystem) fails during a power outage. The adequately shielded data cables must be used. All data and signal cables must have sufficient shielding. The use of cable type S/FTP Cat5 or higher is recommended. Use of unshielded or badly shielded cables may lead to increased emission of interference and/or reduced fault-tolerance of the device. Ethernet cabling has to comply with EN and EN /2 standards or ISO/IEC standard respectively. The minimum requirement is a Category 5 shielded cable for 10/100 Ethernet, or a Category 5e cable for Gigabit Ethernet. Route the cables in such a way that they do not create a potential hazard (make sure no-one can trip over them) and that they cannot be damaged. When connecting the server enclosure, refer to the relevant instructions in this manual. Never connect or disconnect data transmission lines during a storm (risk of lightning hazard). Make sure that no objects (e.g. jewelry, paperclips etc.) or liquids can get inside the server enclosure (risk of electric shock, short circuit). In emergencies (e.g. damaged casing, controls or cables, penetration of liquids or foreign bodies), contact the server enclosure administrator or your customer service team. Only disconnect the server enclosure from the mains power supply if there is no risk of harming yourself. Proper operation of the server enclosure (in accordance with IEC resp. EN ) is only ensured if the server enclosure is completely assembled and the rear covers for the installation slots have been fitted (electric shock, cooling, fire protection, interference suppression). Only install server enclosure expansions that satisfy the requirements and rules governing safety and electromagnetic compatibility and those relating to telecommunication terminals. If you install other expansions, they may damage the server enclosure or violate the safety regulations. Information on which server enclosure expansions are approved for installation can be obtained from our customer service center or your sales outlet. CX400 M4 Operating Manual 23

24 Important information The components marked with a warning notice (e.g. lightning symbol) may only be opened, removed or exchanged by authorized, qualified personnel. Exception: CSS components can be replaced. The warranty is void if the server enclosure is damaged during installation or replacement of server enclosure expansions. Only set screen resolutions and refresh rates that are specified in the operating manual for the monitor. Otherwise, you may damage your monitor. If you are in any doubt, contact your sales outlet or customer service center. Only valid for non hot-plug components Before installing/removing internal components to/from the server enclosure, turn off the server enclosure, all peripheral devices, and any other connected devices. Also unplug all power cords from the power outlet. Failure to do so can cause electric shock or damage. Internal devices remain hot after shutdown. Wait for a while after shutdown before installing or removing internal options. Do not damage or modify internal cables or internal devices. Doing so may cause a server enclosure failure, fire, or electric shock and will void the warranty and exempt the manufacturer from all liability. The circuit boards and soldered parts of internal options are exposed and can be damaged by static electricity. To ensure reliable protection, you must wear an earthing band on your wrist when working with this type of module and connect it to an unpainted, conducting metal part of the server enclosure. Do not touch the circuitry on boards or soldered parts. Hold the metallic areas or the edges of the circuit boards. Install the screw removed during installation/detaching internal options in former position. To use a screw of the different kind can cause a breakdown of equipment. The procedure of installation on this notes might change depending on a configuration of option. Batteries Incorrect replacement of batteries may lead to a risk of explosion. The batteries may only be replaced with identical batteries or with a type recommended by the manufacturer. Do not throw batteries into the trash can. 24 Operating Manual CX400 M4

25 Important information Batteries must be disposed of in accordance with local regulations concerning special waste. Make sure that you insert the battery the right way round. The battery used in this server enclosure may present a fire or chemical burn hazard if mistreated. Do not disassemble, heat about 100 C (212F), or incinerate the battery. Replace the lithium battery on the system board in accordance with the instructions in the corresponding Upgrade and Maintenance Manual, chapter "System board and components" > "CMOS battery". All batteries containing pollutants are marked with a symbol (a crossed-out garbage can). In addition, the marking is provided with the chemical symbol of the heavy metal decisive for the classification as a pollutant: Cd Cadmium Hg Mercury Pb Lead Working with optical disk drives and media When working with optical disk drives, these instructions must be followed. V CAUTION! Only use CDs/DVDs/BDs that are in perfect condition, in order to prevent data loss, equipment damage and injury. Check each CD/DVD/BD for damage, cracks, breakages etc. before inserting it in the drive. Note that any additional labels applied may change the mechanical properties of a CD/DVD/BD and cause imbalance and vibrations. Damaged and imbalanced CDs/DVDs/BDs can break at high drive speeds (data loss). Under certain circumstances, sharp CD/DVD/BD fragments can pierce the cover of the optical disk drive (equipment damage) and can fly out of the drive (danger of injury, particularly to uncovered body parts such as the face or neck). High humidity and airborne dust levels are to be avoided. Electric shocks and/or server enclosure failures may be caused by liquids such as water, or metallic items, such as paper clips, entering a drive. CX400 M4 Operating Manual 25

26 Important information Shocks and vibrations are also to be avoided. Do not insert any objects other than the specified CDs/DVDs/BDs. Do not pull on, press hard, or otherwis e handle the CD/DVD/BD tray roughly. Do not dissasemble the optical disk drive. Before use, clean the optical disk tray using a soft, dry cloth. As a precaution, remove disks from the optical disk drive when the drive is not to be used for a long time. Keep the optical disk tray closed to prevent foreign matter, such as dust, from entering the optical disk drive. Hold CDs/DVDs/BDs by their edges to avoid contact with the disk surface. Do not contaminate the CD/DVD/BD surface with fingerprints, oil, dust, etc. If dirty, clean with a soft, dry cloth, wiping from the center to the edge. Do not use benzene, thinners, water, record sprays, antistatic agents, or silicone-impregnated cloth. Be careful not to damage the CD/DVD/BD surface. Keep the CDs/DVDs/BDs away from heat sources. Do not bend or place heavy objects on CDs/DVDs/BDs. Do not write with ballpoint pen or pencil on the label (printed) side. Do not attach stickers or similar to the label side. Doing so may cause rotational eccentricity and abnormal vibrations. When a CD/DVD/BD is moved from a cold place to a warm place, moisture condensation on the CD/DVD/BD surface can cause data read errors. In this case, wipe the CD/DVD/BD with a soft, dry cloth then let it air dry. Do not dry the CD/DVD/BD using devices such as a hair dryer. To avoid dust, damage, and deformation, keep the CD/DVD/BD in its case whenever it is not in use. Do not store CDs/DVDs/BDs at high temperatures. Areas exposed to prolonged direct sunlight or near heating appliances are to be avoided. 26 Operating Manual CX400 M4

27 Important information I You can prevent damage from the optical disk drive and the CDs/DVDs/BDs, as well as premature wear of the disks, by observing the following suggestions: Only insert disks in the drive when needed and remove them after use. Store the disks in suitable sleeves. Protect the disks from exposure to heat and direct sunlight. Laser information The optical disk drive complies with IEC laser class 1. V CAUTION! The optical disk drive contains a light-emitting diode (LED), which under certain circumstances produces a laser beam stronger than laser class 1. Looking directly at this beam is dangerous. Never remove parts of the optical disk drive casing! Modules with Electrostatic-Sensitive Devices (ESD modules) Modules with electrostatic-sensitive devices are identified by the following sticker: Figure 2: ESD label I The ESD label can be different. When you handle ESD modules, you must always observe the following points: Switch off the server enclosure and remove the power plugs from the power outlets before installing or removing ESD modules. CX400 M4 Operating Manual 27

28 Important information The circuit boards and soldered parts of internal options are exposed and can be damaged by static electricity. To ensure reliable protection, you must wear an earthing band on your wrist when working with ESD modules and connect it to an unpainted, conducting metal part of the server enclosure. Any devices or tools that are used must be free of electrostatic charge. Wear a suitable grounding cable that connects you to the external chassis of the server enclosure. Always hold ESD modules at the edges or at the points marked green (touch points). Do not touch any connectors or conduction paths on an ESD module. Place all the components on a pad which is free of electrostatic charge. I For a detailed description of how to handle ESD modules, see the relevant European or international standards (EN , ANSI/ESD S20.20). Transporting the server enclosure V CAUTION! Only transport the server enclosure in its original packaging or in packaging that protects it from impacts and jolts. In Japan and APAC, transporting the server enclosure in its original packaging does not apply. Do not unpack the server enclosure until it is at its installation location. If you need to lift or transport the server enclosure, ask other people to help you. Never lift or carry the server enclosure by the handles or the Quick Release Levers (QRLs) on the front panel. Notes on installing the server enclosure in the rack V CAUTION! For safety reasons, at least 2 people are required to install the server enclosure in the rack because of its weight and size. (For the reader in Japan, please refer to " 安全上のご注意 ".) Never lift the server enclosure into the rack using the QRLs (Quick Release Levers) on the front panel. 28 Operating Manual CX400 M4

29 Important information When connecting and disconnecting cables, observe the relevant instructions in the "Important Information" chapter of the technical manual for the corresponding rack. The technical manual is supplied with the corresponding rack. When installing the rack, make sure that the anti-tilt mechanism is correctly fitted. Do not extend more than one server enclosure out of the rack simultaneously even if the tilt protection is in place. If several server enclosures are simultaneously extended from the rack, there is a risk that the rack could tip over. See the safety information of the rack and the warning label. If the server enclosure/rack is intended for permanent connection to the mains only an authorized specialist (electrician) is allowed to work. Please follow the regulation of each country. If the server enclosure is integrated into an installation that draws power from an industrial power supply network with an IEC309 type connector, the power supply's fuse protection must comply with the requirements for non-industrial power supply networks for the type A connector. Other important information During cleaning, observe the instructions in the corresponding Operating Manual chapter "Starting up and operation" > "Cleaning the server enclosure". Keep all manuals close to the server enclosure. All documentation must be included if the equipment is passed on to a third party. CX400 M4 Operating Manual 29

30 Important information 4.2 ENERGY STAR Products that have been certified compliant with ENERGY STAR and labelled are in full compliance with the specification at shipping. Note that energy consumption can be affected by software that is installed or any changes that are made to the hardware configuration or BIOS or energy options subsequently. In such cases, the properties guaranteed by ENERGY STAR can no longer be assured. The "ServerView Operations Manager" user guide contains instructions for reading out measurement values, including those relating to current energy consumption and air temperatures. Either the Performance Monitor or the Task Manager can be used to read out CPU utilization levels. 4.3 CE conformity :The system complies with the requirements of European Regulations. Find the CE declaration on certificate portal: To open the CE declaration applicable for your system, proceed as follows: Select Industry Standard Servers. Select your model, e.g. Rack server. Select your system, e.g. PRIMERGY RX2530 M1. Select CE Cert <your system>. V CAUTION! This is a Class A product. In a domestic environment this product may cause RF interference, in which case the user may be required to take adequate measures. 30 Operating Manual CX400 M4

31 Important information 4.4 FCC Class A Compliance Statement If there is an FCC statement on the device, it applies to the products covered in this manual, unless otherwise specified herein. The statement for other products will appear in the accompanying documentation. NOTE: This equipment has been tested and found to comply with the limits for a "Class A" digital device, pursuant to Part 15 of the FCC rules and meets all requirements of the Canadian Interference-Causing Equipment Standard ICES-003 for digital apparatus. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in strict accordance with the instructions, may cause harmful interference to radio communications. However, there is no warranty that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna. Increase the separation between equipment and the receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/tv technician for help. Fujitsu is not responsible for any radio or television interference caused by unauthorized modifications of this equipment or the substitution or attachment of connecting cables and equipment other than those specified by Fujitsu. The correction of interferences caused by such unauthorized modification, substitution or attachment will be the responsibility of the user. The use of shielded I/O cables is required when connecting this equipment to any and all optional peripheral or host devices. Failure to do so may violate FCC and ICES rules. CX400 M4 Operating Manual 31

32 Important information 4.5 Environmental protection Environmentally-friendly product design and development This product has been designed in accordance with the Fujitsu standard for "environmentally friendly product design and development". This means that key factors such as durability, selection and labeling of materials, emissions, packaging, ease of dismantling and recycling have been taken into account. This saves resources and thus reduces the harm done to the environment. Further information can be found at: For the reader in Japan: Energy-saving information Devices that do not need to be constantly switched on should be switched off until they are needed as well as during long breaks and after completion of work. Packaging information This packaging information does not apply in Japan and APAC. Do not throw away the packaging. You may need it later for transporting the server enclosure. If possible, the equipment should only be transported in its original packaging. Information on handling consumables Please dispose of printer consumables and batteries in accordance with the applicable national regulations. In accordance with EU directives, batteries must not be disposed of with unsorted domestic waste. They can be returned free of charge to the manufacturer, dealer or an authorized agent for recycling or disposal. All batteries containing pollutants are marked with a symbol (a crossed-out garbage can). They are also marked with the chemical symbol for the heavy metal that causes them to be categorized as containing pollutants: Cd Cadmium Hg Mercury Pb Lead 32 Operating Manual CX400 M4

33 Important information Labels on plastic casing parts Please avoid sticking your own labels on plastic parts wherever possible, since this makes it difficult to recycle them. Returns, recycling and disposal Please handle returns, recycling and disposal in accordance with local regulations. The device must not be disposed of with domestic waste. This device is labeled in compliance with European directive 2012/19/EU on waste electrical and electronic equipment (WEEE). This directive sets the framework for returning and recycling used equipment and is valid across the EU. When returning your used device, please use the return and collection systems available to you. Further information can be found at: Details regarding the return and recycling of devices and consumables within Europe can also be found in the "Returning used devices" manual, via your local Fujitsu branch, or at: Transporting the server enclosure V CAUTION! Only transport the server enclosure in its original packaging or in packaging that protects it from impacts and jolts. Do not unpack the server enclosure until it is at its installation location. If you need to lift or transport the server enclosure, ask other people to help you. CX400 M4 Operating Manual 33

34 Important information 4.7 Notes on installing the server enclosure in the rack V CAUTION! For safety reasons, at least two people are required to install the server enclosure in the rack because of its weight and size. (For Japan, please refer to " 安全上のご注意 ".) Never lift the server enclosure into the rack using the handles. When connecting and disconnecting cables, observe the relevant instructions in the "Important Information" chapter of the operating manual for the corresponding rack. The operating manual is supplied with the corresponding rack. When installing the rack, make sure that the anti-tilt mechanism is correctly fitted. For safety reasons, no more than one unit may be removed from the rack at any one time during installation and maintenance work. If several units are simultaneously removed from the rack, there is a risk that the rack could tip over. The rack must be connected to the power supply by an authorized specialist (electrician). If the server enclosure is integrated into an installation that draws power from an industrial power supply network with an IEC309 type connector, the PSU's fuse protection must comply with the requirements for non-industrial power supply networks for the type A connector. 34 Operating Manual CX400 M4

35 5 Hardware installation V CAUTION! Follow the safety instructions in chapter "Important information" on page 21. Do not expose the server enclosure to extreme environmental conditions (see "Ambient conditions" on page 15). Protect the server enclosure from dust, humidity and heat. Make sure that the server enclosure is acclimatized for the time indicated in this table before putting it into operation. Temperature difference ( C) Minimum acclimatization time (hours) Table 1: Acclimatization time In the table "Acclimatization time", the temperature difference refers to the difference between the operating environment temperature and the temperature to which the server enclosure was exposed previously (outside, transport or storage temperature). CX400 M4 Operating Manual 35

36 Hardware installation 5.1 Unpacking the server enclosure V CAUTION! Follow the safety instructions in chapter "Important information" on page 21. Transport the server enclosure to the place where you want to set it up. Do not unpack the server enclosure until it is at its installation location. Unpack all the individual parts. I Keep the original packaging in case you want to transport the server enclosure again. Check the delivery for any damage during transport. Check whether the items delivered match the details on the delivery note. The product name and serial number of the product can be found on the identification rating plate. It is located on the underside of the server enclosure, at the front on the right. If the delivery is damaged or does not match the delivery note, contact your supplier immediately! 36 Operating Manual CX400 M4

37 Hardware installation 5.2 Installing/removing the server enclosure in/from the rack V CAUTION! Please observe the safety information and notes on rack mounting in chapter "Important information" on page 21. At least two people are needed to install / remove the server enclosure in the rack. (For Japan, please refer to " 安全上のご注意 ".) Do not extend more than one unit out of the rack simultaneously even if the tilt protection is in place. If several units are simultaneously extended out of the rack, there is a risk that the rack could tip over. Fujitsu rack systems The rack systems from Fujitsu support the installation of PRIMERGY server enclosures: PRIMECENTER rack PRIMECENTER M4 rack DataCenter rack 19-inch standard rack (for Japan) 19-inch slimline rack (for Japan) I For information on mounting the server enclosure in the rack please refer to the mounting instructions provided in this section. Further information see the manual of your rack system. For Japan, please refer also to the "Rack system structure guide". I Online documentation for rack installation can be found on: (for the global market) (for Japan). To accommodate the ventilation concept and ensure proper ventilation, any unused areas in the rack must be sealed using dummy covers. The power is supplied via the multiple socket outlets fitted in the rack (for the global market). The main features of Fujitsu rack systems are as follows: CX400 M4 Operating Manual 37

38 Hardware installation support systems having a linear alignment feature to ensure that they can be adjusted to different rack depths Asymmetrical PRIMECENTER Rack and DataCenter Rack provide an enhanced cable management in the lateral rack area. 3rd party racks I Installation in most current rack systems from other manufacturers (3rd party racks) is also supported. For details please contact your sales representative. 38 Operating Manual CX400 M4

39 Hardware installation Mounting the server enclosure in the rack Removing the inner rail from the carrier rails Identify the inner rail and the outer rail. Figure 3: Inner (2) and outer rail (1) Figure 4: Starting position of inner and outer rail Push the lever (1) and pull the inner rail as far as possible towards the front side (2). CX400 M4 Operating Manual 39

40 Hardware installation Figure 5: Turning outer rail Turn the rails to the other side (see arrow). Figure 6: Removing inner rail from outer rail Push the locking latch (1) and pull the outer rail as far as possible towards the front side (2). Now the inner rail is removed from the outer rail. 40 Operating Manual CX400 M4

41 Hardware installation Attaching the carrier rails to the server enclosure Identify the right and the left rail. Figure 7: Attaching the right carrier rail Move the right carrier rail towards the server enclosure and position the holes onto the positioning screws (1).The carrier rail must lock in the corresponding hole. Push the carrier rail towards the front side until it locks into the supporting holes nicely (2). Figure 8: Fixing the carrier rail Fasten the carrier rail with two M4 screws (3). Repeat this procedure to install the left carrier rail. CX400 M4 Operating Manual 41

42 Hardware installation Installing the carrier rails Clarify the position of the system unit in the rack. Mark the position of the bottom edge of the server enclosure on the support uprights. Identify the right and the left rail. Figure 9: Attaching the left carrier rail Figure 10: Adjusting the positioning clip Move the left carrier rail towards the rear side (2) while holding the positioning clip (1). The mounting aid must lock in the corresponding holes. Release the positioning clip (1) after the designated position is reached. 42 Operating Manual CX400 M4

43 Hardware installation Move the left rail towards the front side (4) while holding the positioning clip (3). The mounting aid must lock in the corresponding hole. Release the positioning clip (5) after the designated position is reached. Repeat this procedure to install the right rail. Installing the server enclosure into the rack V CAUTION! At least two people are needed to position the server on the rack rails. (For Japan, please refer to " 安全上のご注意 ".) For configurations below 32 kg: At least two people are needed to lift the server into the rack cabinet. For configurations below 55 kg: At least three people are needed to lift the server into the rack cabinet. For configurations above 55 kg: At least four people are needed to lift the server into the rack cabinet. Additionally, a lifter is required in the following cases: The server weighs more than 50 kg. The server weighs more than 21 kg and is to be installed above the height of 25 U. CX400 M4 Operating Manual 43

44 Hardware installation When using a lifter, this installation procedure needs to be carried out by maintenance personnel. I At least two people are needed to position the server on the rack rails. 1 2 Figure 11: Mounting the server enclosure into the rack (A). Set the back-end of both inner rails (1) into the front entry of the both outer rails (2). Figure 12: Mounting the server enclosure into the rack (A) Push the server enclosure as far as possible into the rack. 44 Operating Manual CX400 M4

45 Hardware installation Figure 13: Mount the server enclosure in the rack. When the server enclosure is stopped, push the locking latch (1) on both sides and push the server in the rack (2). Figure 14: Mounting the server enclosure into the rack (B). Push the enclosure into the rack (1) until the locking mechanism engages. CX400 M4 Operating Manual 45

46 Hardware installation Removing the server enclosure out of the rack V CAUTION! At least two people are needed to position the server on the rack rails. (For Japan, please refer to " 安全上のご注意 ".) For configurations below 32 kg: At least two people are needed to lift the server into the rack cabinet. For configurations below 55 kg: At least three people are needed to lift the server into the rack cabinet. For configurations above 55 kg: At least four people are needed to lift the server into the rack cabinet. Additionally, a lifter is required in the following cases: The server weighs more than 50 kg. The server weighs more than 21 kg and is to be installed above the height of 25 U. When using a lifter, this installation procedure needs to be carried out by maintenance personnel. 46 Operating Manual CX400 M4

47 Hardware installation V CAUTION! At least two people are needed to lift the server out of the rack cabinet. For Japan, according to the following procedures. If you remove the CX400 M4 server enclosure out of the rack, remove all HDD, PSU and Server Node from the server enclosure. In addition, at least two people are needed when server enclosure is installed in the height of 25U or more. (for Japan, please refer to " 安全上のご注意 ".) For configurations below 32 kg: At least two people are needed to lift the server out of the rack cabinet. For configurations below 55 kg: At least three people are needed to lift the server out of the rack cabinet. For configurations above 55 kg: At least four people are needed to lift the server out of the rack cabinet. Additionally, a lifter is required in the following cases: The server weighs more than 50 kg. The server weighs more than 21 kg and is installed above the height of 25 U. When using a lifter, this removal procedure needs to be carried out by maintenance personnel. CX400 M4 Operating Manual 47

48 Hardware installation Figure 15: Removing the server enclosure out of the rack (A) While pressing the locking levers (1) on both sides of the enclosure use the brackets (2) to pull the server enclosure out of its lock. Figure 16: Removing the server enclosure out of the rack (B) When the server is stopped, push the locking latch (1) on both sides and pull the server out of the rack (2). 48 Operating Manual CX400 M4

49 Hardware installation Figure 17: Removing the server enclosure out of the rack (B) Pull out the chassis from the rack. I Remove the server enclosure from the rack carefully. Must be done with at least two people. CX400 M4 Operating Manual 49

50 Hardware installation 5.3 Connecting the server enclosure to the mains The system has two bays for hot-plug PSUs. Each hot-plug PSU can be replaced during operation (see the "FUJITSU Server PRIMERGY CX400 M4 Server Enclosure Upgrade and Maintenance Manual"). V CAUTION! The server enclosure is automatically set to a mains voltage in the range V. You may only operate the server enclosure if its rated voltage range corresponds to the local mains voltage. Connect the power cord to the server enclosure PSU. Connect the mains connector to an outlet on the rack's socket strip (see also Technical Manual for the rack). I A phase redundancy in the power supply of the server enclosure can be set up if two hot-plug PSUs are installed. In this case, each of the PSUs is either connected to two different phases or to two separate circuits of the internal power supply network. 50 Operating Manual CX400 M4

51 Hardware installation 5.4 Notes on connecting/disconnecting cables V CAUTION! Always read the documentation supplied with the device you wish to connect. Never connect, or disconnect cables during a thunderstorm. Never pull on a cable when disconnecting it. Always take hold of the cable by the plug. Follow the sequence described below to connect or disconnect external devices to or from the server enclosure: Be sure to wait for 10 seconds or more after shutdown before turning the server enclosure on. Connecting cables Turn off all power and equipment switches. Disconnect all power plugs from the properly grounded power outlets. Connect all cables to the server enclosure and peripherals. Plug all data communication cables into the utility sockets. Plug all power cords into the properly grounded power outlets. Disconnecting cables Turn off all power and equipment switches. Disconnect all power plugs from the properly grounded power outlets. Unplug all data communication cables from the utility sockets. Disconnect the relevant cables from the server enclosure and all the peripherals. I For connecting or disconnecting LAN cables, the server enclosure does not need to be powered off. To avoid loss of data teaming function has to be enabled. CX400 M4 Operating Manual 51

52 Hardware installation 52 Operating Manual CX400 M4

53 6 Starting up and operation V CAUTION! Please note the safety instructions in chapter "Important information" on page Overview of the server enclosure Front overview with CX2550 M4 server nodes Figure 18: Configuration with 8x 2.5" HDDs (example) Pos. Component 1 Operating panel for server node 1 2 Operating panel for server node 2 3 Operating panel for server node 3 4 Operating panel for server node 4 5 HDD bays for server node 1 6 HDD bays for server node 2 7 HDD bays for server node 3 8 HDD bays for server node 4 CX400 M4 Operating Manual 53

54 Starting up and operation Front overview with CX2560 M4 / CX2570 M4 server nodes Figure 19: Configuration with 24x 2.5" HDDs (example) Pos. Component 1 Operating panel for server node 1 2 Operating panel for server node 2 3 Operating panel for server node 3 4 Operating panel for server node 4 5 HDD bays for server node 1 6 HDD bays for server node 2 7 HDD bays for server node 3 8 HDD bays for server node 4 54 Operating Manual CX400 M4

55 Starting up and operation Rear overview with CX2550 M4 or CX2560 M4 server nodes Figure 20: PRIMERGY CX400 M4 server enclosure rear with CX2550 M4 or CX2560 M4 server nodes Pos. Component 1 Installation bay 1 for CX2550 M4 or CX2560 M4 server nodes 2 Installation bay 2 for CX2550 M4 or CX2560 M4 server nodes 3 Installation bay 3 for CX2550 M4 or CX2560 M4 server nodes 4 Installation bay 4 for CX2550 M4 or CX2560 M4 server nodes 5 Installation bay 1 for PSU 6 Installation bay 2 for PSU CX400 M4 Operating Manual 55

56 Starting up and operation Rear overview with CX2570 M4 server nodes Figure 21: PRIMERGY CX400 M4 server enclosure rear with CX2570 M4 server nodes Pos. Component 1,2 Installation bay 1/2 for CX2570 M4 server nodes 3,4 Installation bay 3/4 for CX2570 M4 server nodes 5 Installation bay 1 for PSU 6 Installation bay 2 for PSU 56 Operating Manual CX400 M4

57 Starting up and operation 6.2 Controls and indicators Front of the server enclosure Figure 22: Controls and indicators on the front panel Pos. Component Related to: 1 PSU CSS indicator server enclosure 2 Fan CSS indicator server enclosure 3 Global error indicator server enclosure 4 AC connected indicator server enclosure 5 Global error indicator server node 1 6 ID button server node 1 7 ID indicator server node 1 8 Power-on indicator server node 1 9 On/Off button server node 1 10 Power-off indicator (AC connected) server node 1 11 CSS indicator server node 1 I Each server node has a separate operation area marked with the corresponding number. In the table above, server node 1 is used as an example CX400 M4 Operating Manual 57

58 Starting up and operation Indicators on the front panel (enclosure-related) PSU FAN! PSU CSS indicator (orange) Lights up orange if a hot-plug PSU prefailure event has been detected that requires (precautionary) service intervention. Flashes orange if a hot-plug PSU error was detected that requires service intervention. Does not light up if there is no critical event. I To examine, which hot-plug PSU is affected, refer to the indicators on the hot-plug PSUs. FAN CSS indicator (orange) Lights up orange if a fan module prefailure event has been detected that requires (precautionary) service intervention. Flashes orange if a fan module error was detected that requires service intervention. Does not light up if there is no critical event. I To examine, which fan module is affected, refer to the diagnostic panel on the cover of the server enclosure. Global error indicator (orange) Lights up orange if a prefailure event has been detected that requires (precautionary) service intervention. Flashes orange if an error was detected that requires service intervention. Does not light up if there is no critical event. If the event is still acute after a power cycle, the indicator is activated after the restart. The indicator also lights up in standby mode. You can find more details on the indicated errors in the System Event Log (SEL), in the ServerView Operations Manager or via the irmc S5 web interface. 58 Operating Manual CX400 M4

59 Starting up and operation AC-connected indicator Lights up green if the server enclosure is connected to the mains. CX400 M4 Operating Manual 59

60 Starting up and operation Indicators on the front panel (node-related) Power-on indicator (green) Does not light up when the server node is switched OFF. Lights up green when the server node is in power-on delay and while the system is in normal operation (S0). Flashes slowly (1/2 Hz) green when the irmc S5 is initialized and is getting ready. Power-off indicator (AC connected) (green) located above the On/Off button Does not light up in the following cases: the server node is not connected to the mains the server node is powered on and in normal operation (S0) Lights up green in the following cases: the server node is in power-off mode but connected to the mains (AC connected) the server node has been switched on and is in power-on delay I After connecting the server enclosure to the mains it takes about 60 seconds until the server nodes enter the standby mode.! Global error indicator (orange) Lights up orange if a prefailure event has been detected that requires (precautionary) service intervention. Flashes orange if an error was detected that requires service intervention. Does not light up if there is no critical event. If the event is still acute after a power cycle, the indicator is activated after the restart. The indicator also lights up in standby mode. You can find more details on the indicated errors in the System Event Log (SEL), in the ServerView Operations Manager or via the irmc S5 web interface. 60 Operating Manual CX400 M4

61 Starting up and operation CSS indicator (orange) Lights up orange if a prefailure event was detected for a CSS component that you can fix yourself (for reasons of precaution) with the CSS concept. Flashes orange if an error was detected that you can fix yourself with the CSS concept. Does not light up when the supervised components are OK. If the event is still acute after a power cycle, the indicator is activated after the restart. The indicator also lights up in standby mode. ID ID indicator (blue) Lights up blue when the server node has been highlighted using ServerView Operations Manager, the irmc web frontend, or the ID button on the front panel for easy identification. CX400 M4 Operating Manual 61

62 Starting up and operation ID card Figure 23: ID card You can pull out the ID card (1) as far as it will go and push it back again. The ID card contains various system information, such as the product name, serial number, order number, MAC addresses and DNS name (in Japan, only the serial number of the chassis and each node). 62 Operating Manual CX400 M4

63 Starting up and operation Indicators on the HDDs Figure 24: Indicators on the 2.5 inch HDD modules 1 HDD/SSD FAULT indicator (orange) (in conjunction with a RAID controller) Does not light: no HDD error Lights up: HDD Faulty or Rebuild Stopped (drive defective/needs replacing, a rebuild process was stopped or the HDD module is not correctly inserted) Slow flashing: HDD Rebuild (the data is being restored after changing a drive) Fast flashing: HDD Identify Four fast blinks/pause: HDD Predicted Fault Two fast flashes/pause: HDD Hot Spare (Hot spare drive active. The corresponding drive has failed). 2 HDD/SSD BUSY indicator (green) Lights up: HDD in active phase Does not light: HDD inactive (drive inactive) CX400 M4 Operating Manual 63

64 Starting up and operation Indicator on hot-plug PSU Figure 25: Indicator on hot-plug PSU 1 Indicator on hot-plug PSU (two colors) Flashes green when the all server nodes is switched off, but AC voltage is present (standby mode). Lights up green when the one or more server nodes is switched on and functioning properly. Flashes orange in case of overload, but the power supply unit is still running. Lights up orange in case of PSU failure, overvoltage / undervoltage, overtemperature, fan fail Indicators of the server nodes I For the description of the indicators of the server nodes, refer to the operating manuals of the relevant server nodes. 64 Operating Manual CX400 M4

PRIMERGY CX400 S2 Server Enclosure

PRIMERGY CX400 S2 Server Enclosure Operating Manual - English PRIMERGY CX400 S2 Server Enclosure Operating Manual Edition December 2013 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of

More information

PRIMERGY CX400 S1 Server Enclosure

PRIMERGY CX400 S1 Server Enclosure Upgrade and Maintenance Manual - English PRIMERGY CX400 S1 Server Enclosure Upgrade and Maintenance Manual Edition December 2012 Comments Suggestions Corrections The User Documentation Department would

More information

Operating Manual - English. RDX USB 3.0 QuikStor Drive

Operating Manual - English. RDX USB 3.0 QuikStor Drive Operating Manual - English RDX USB 3.0 QuikStor Drive December 2017 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps

More information

PRIMERGY BX400 S1 System Unit

PRIMERGY BX400 S1 System Unit Options Guide - English PRIMERGY BX400 S1 System Unit Options Guide December 2010 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your

More information

FUJITSU Server PRIMERGY RX1330 M1

FUJITSU Server PRIMERGY RX1330 M1 Upgrade and Maintenance Manual - English FUJITSU Server PRIMERGY RX1330 M1 Upgrade and Maintenance Manual August 2014 Comments Suggestions Corrections The User Documentation Department would like to know

More information

FUJITSU Server PRIMERGY RX2510 M2

FUJITSU Server PRIMERGY RX2510 M2 Operating Manual - English FUJITSU Server PRIMERGY RX2510 M2 Operating Manual February 2016 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual.

More information

PRIMERGY SX650 Storage Blade. Operating Manual

PRIMERGY SX650 Storage Blade. Operating Manual PRIMERGY SX650 Storage Blade Operating Manual Edition April 2009 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps us

More information

PRIMERGY SX910 S1 Storage Blade

PRIMERGY SX910 S1 Storage Blade Operating Manual - English PRIMERGY SX910 S1 Storage Blade Operating Manual Edition March 2011 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this

More information

PRIMERGY SX940 S1 Storage Blade

PRIMERGY SX940 S1 Storage Blade Operating manual - English PRIMERGY SX940 S1 Storage Blade Operating manual Edition March 2011 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this

More information

Data Sheet FUJITSU Server PRIMERGY CX400 M1 Scale out Server

Data Sheet FUJITSU Server PRIMERGY CX400 M1 Scale out Server Data Sheet FUJITSU Server Scale out Server Data Sheet FUJITSU Server Scale out Server Scale-Out Smart for HPC, Cloud and Hyper-Converged Computing FUJITSU Server PRIMERGY will give you the servers you

More information

PRIMERGY TX120 S2 Server. Service Supplement

PRIMERGY TX120 S2 Server. Service Supplement PRIMERGY TX120 S2 Server Service Supplement Edition July 2009 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps us optimize

More information

FUJITSU Server PRIMERGY RX1330 M2

FUJITSU Server PRIMERGY RX1330 M2 Upgrade and Maintenance Manual - English FUJITSU Server PRIMERGY RX1330 M2 Upgrade and Maintenance Manual December 2015 Comments Suggestions Corrections The User Documentation Department would like to

More information

Data Sheet Fujitsu Server PRIMERGY CX400 M1 Compact and Easy

Data Sheet Fujitsu Server PRIMERGY CX400 M1 Compact and Easy Data Sheet Fujitsu Server Compact and Easy Data Sheet Fujitsu Server Compact and Easy Scale-Out Smart for HPC, Cloud and Hyper-Converged Computing The Fujitsu Server helps to meet the immense challenges

More information

PRIMERGY BX920 S3 Server Blade

PRIMERGY BX920 S3 Server Blade Upgrade and Maintenance Manual - English PRIMERGY BX920 S3 Server Blade Upgrade and Maintenance Manual Edition February 2014 Comments Suggestions Corrections The User Documentation Department would like

More information

PRIMERGY TX100 S3 Server

PRIMERGY TX100 S3 Server Operating Manual - English PRIMERGY TX100 S3 Server Operating Manual Edition November 2011 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual.

More information

FUJITSU Server PRIMERGY RX1330 M3

FUJITSU Server PRIMERGY RX1330 M3 Upgrade and Maintenance Manual - English FUJITSU Server PRIMERGY RX1330 M3 Upgrade and Maintenance Manual April 2017 Comments Suggestions Corrections The User Documentation Department would like to know

More information

FUJITSU Server PRIMERGY TX1320 M3

FUJITSU Server PRIMERGY TX1320 M3 Operating Manual - English FUJITSU Server PRIMERGY TX1320 M3 Operating Manual March 2017 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual.

More information

FUJITSU Server PRIMERGY RX100 S8

FUJITSU Server PRIMERGY RX100 S8 Upgrade and Maintenance Manual - English FUJITSU Server PRIMERGY RX100 S8 Upgrade and Maintenance Manual April 2015 Comments Suggestions Corrections The User Documentation Department would like to know

More information

FUJITSU Server PRIMERGY RX1330 M3

FUJITSU Server PRIMERGY RX1330 M3 Operating Manual - English FUJITSU Server PRIMERGY RX1330 M3 Operating Manual March 2017 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual.

More information

FUJITSU Server PRIMERGY RX2510 M2

FUJITSU Server PRIMERGY RX2510 M2 Upgrade and Maintenance Manual - English FUJITSU Server PRIMERGY RX2510 M2 Upgrade and Maintenance Manual June 2017 Comments Suggestions Corrections The User Documentation Department would like to know

More information

FUJITSU Server PRIMERGY RX2510 M2

FUJITSU Server PRIMERGY RX2510 M2 Operating Manual - English FUJITSU Server PRIMERGY RX2510 M2 Operating Manual June 2017 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual.

More information

PRIMERGY CX272 S1 Server Node

PRIMERGY CX272 S1 Server Node Upgrade and Maintenance Manual - English PRIMERGY CX272 S1 Server Node Upgrade and Maintenance Manual February 2014 Comments Suggestions Corrections The User Documentation Department would like to know

More information

Operating Manual - English. FUJITSU Server PRIMERGY TX1330 M3 Operating Manual

Operating Manual - English. FUJITSU Server PRIMERGY TX1330 M3 Operating Manual Operating Manual - English FUJITSU Server PRIMERGY TX1330 M3 Operating Manual May2017 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual.

More information

PRIMERGY MX130 S2 Server

PRIMERGY MX130 S2 Server Upgrade and Maintenance Manual - English PRIMERGY MX130 S2 Server Upgrade and Maintenance Manual Edition November 2011 Comments Suggestions Corrections The User Documentation Department would like to know

More information

PRIMERGY BX924 S2 Server Blade

PRIMERGY BX924 S2 Server Blade Operating Manual - English PRIMERGY BX924 S2 Server Blade Operating Manual Edition May 2011 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual.

More information

PRIMERGY BX920 S2 Server Blade

PRIMERGY BX920 S2 Server Blade Operating Manual - English PRIMERGY BX920 S2 Server Blade Operating Manual Edition March 2011 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this

More information

FUJITSU Server PRIMERGY RX100 S8

FUJITSU Server PRIMERGY RX100 S8 Operating Manual - English FUJITSU Server PRIMERGY RX100 S8 Operating Manual Edition May 2014 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this

More information

FUJITSU Server PRIMERGY TX1330 M2

FUJITSU Server PRIMERGY TX1330 M2 Operating Manual - English FUJITSU Server PRIMERGY TX1330 M2 Operating Manual December 2016 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual.

More information

Data Sheet FUJITSU Server PRIMERGY CX400 S2 Multi-Node Server Enclosure

Data Sheet FUJITSU Server PRIMERGY CX400 S2 Multi-Node Server Enclosure Data Sheet FUJITSU Server PRIMERGY CX400 S2 Multi-Node Server Enclosure Data Sheet FUJITSU Server PRIMERGY CX400 S2 Multi-Node Server Enclosure Scale-Out Smart for HPC and Cloud Computing with enhanced

More information

USER GUIDE. AXIS T8120 Midspan 15 W 1-port ENGLISH

USER GUIDE. AXIS T8120 Midspan 15 W 1-port ENGLISH USER GUIDE AXIS T8120 Midspan 15 W 1-port ENGLISH Legal Considerations Video and audio surveillance can be prohibited by laws that vary from country to country. Check the laws in your local region before

More information

DS-1H05 Ethernet-over-Coax Extender. User Manual

DS-1H05 Ethernet-over-Coax Extender. User Manual DS-1H05 Ethernet-over-Coax Extender User Manual Thank you for purchasing our product. If there is any question or request, please do not hesitate to contact dealer. This manual is applicable to DS-1H05-T,

More information

PRIMERGY RX100 S7 Server

PRIMERGY RX100 S7 Server Operating Manual - English PRIMERGY RX100 S7 Server Operating Manual Edition June 2011 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual.

More information

The following symbols are used to show dangerous operation or handling. Make sure you understand them before reading the guide.

The following symbols are used to show dangerous operation or handling. Make sure you understand them before reading the guide. Safety Instructions Before use Thank you very much for purchasing this product. This product is an interface box called "Connection & Control Box" for EPSON short throw projectors. For your safety, read

More information

FUJITSU Server PRIMERGY TX1320 M3

FUJITSU Server PRIMERGY TX1320 M3 Upgrade and Maintenance Manual - English FUJITSU Server PRIMERGY TX1320 M3 Upgrade and Maintenance Manual April 2017 Comments Suggestions Corrections The User Documentation Department would like to know

More information

FUJITSU Server PRIMERGY RX2530 M4

FUJITSU Server PRIMERGY RX2530 M4 Operating Manual - English FUJITSU Server PRIMERGY RX2530 M4 Operating Manual July 2017 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual.

More information

FUJITSU Server PRIMERGY RX2540 M4

FUJITSU Server PRIMERGY RX2540 M4 Operating Manual - English FUJITSU Server PRIMERGY RX2540 M4 Operating manual July 2017 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual.

More information

PRIMERGY CX122 S1 Server

PRIMERGY CX122 S1 Server Operating Manual - English PRIMERGY CX122 S1 Server Operating Manual Edition November 2010 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual.

More information

FUJITSU Server PRIMERGY RX4770 M2

FUJITSU Server PRIMERGY RX4770 M2 Operating Manual - English FUJITSU Server PRIMERGY RX4770 M2 Operating Manual Edition April 2015 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this

More information

PRIMERGY BX922 S2 Server Blade

PRIMERGY BX922 S2 Server Blade Options Guide - us PRIMERGY BX922 S2 Server Blade Options Guide Edition March 2011 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your

More information

SySTIUM TECHNOLOGIES. Assembly Guide. Model 133i

SySTIUM TECHNOLOGIES. Assembly Guide. Model 133i Assembly Guide Model 133i Radio Frequency Interference Notice (USA) This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules,

More information

PRIMERGY BX620 S6 Server Blade

PRIMERGY BX620 S6 Server Blade Service Supplement - English PRIMERGY BX620 S6 Server Blade Service Supplement September 2010 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this

More information

The following symbols are used to show dangerous operation or handling. Make sure you understand them before reading the guide.

The following symbols are used to show dangerous operation or handling. Make sure you understand them before reading the guide. Safety Instructions Before use Thank you very much for purchasing this product. This product is an interface box called "Connection & Control Box" for EPSON short throw projectors. For your safety, read

More information

PRIMERGY RX100 S6 Server. Operating manual

PRIMERGY RX100 S6 Server. Operating manual PRIMERGY RX100 S6 Server Operating manual Edition December 2009 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps us

More information

Operating Manual - English PRIMERGY RX200 S6. Operating Manual

Operating Manual - English PRIMERGY RX200 S6. Operating Manual Operating Manual - English PRIMERGY RX200 S6 Operating Manual April 2010 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback

More information

PRIMERGY TX120 S3 Server

PRIMERGY TX120 S3 Server Operating Manual - English PRIMERGY TX120 S3 Server Operating Manual Edition May 2012 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual.

More information

Fujitsu Cluster-in-a-box based on PRIMERGY BX400-S/M/L PRIMERGY CX420-S/M

Fujitsu Cluster-in-a-box based on PRIMERGY BX400-S/M/L PRIMERGY CX420-S/M User Guide - English Fujitsu Cluster-in-a-box based on PRIMERGY BX400-S/M/L PRIMERGY CX420-S/M Getting Started Edition April 2013 Comments Suggestions Corrections The User Documentation Department would

More information

FUJITSU Server PRIMERGY TX2540 M1

FUJITSU Server PRIMERGY TX2540 M1 Operating Manual - English FUJITSU Server PRIMERGY TX2540 M1 Operating Manual January 2017 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual.

More information

Mercury Helios ASSEMBLY MANUAL & USER GUIDE

Mercury Helios ASSEMBLY MANUAL & USER GUIDE Mercury Helios ASSEMBLY MANUAL & USER GUIDE TABLE OF CONTENTS INTRODUCTION...1 1.1 MINIMUM SYSTEM REQUIREMENTS 1.1.1 Apple Mac Requirements 1.1.2 PC Requirements 1.1.3 Supported PCIe Cards NOTE: Boot Camp

More information

PRIMERGY RX300 S5. Operating manual

PRIMERGY RX300 S5. Operating manual PRIMERGY RX300 S5 Operating manual Edition september 2009 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps us optimize

More information

PRIMERGY RX600 S5 Server

PRIMERGY RX600 S5 Server Service Supplement - English PRIMERGY RX600 S5 Server Service Supplement June 2010 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your

More information

PRIMERGY RX200 S7 Server

PRIMERGY RX200 S7 Server Operating Manual - English PRIMERGY RX200 S7 Server Operating Manual Edition November 2013 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual.

More information

Data Sheet FUJITSU Server PRIMERGY CX400 M4 Scale out Server

Data Sheet FUJITSU Server PRIMERGY CX400 M4 Scale out Server Data Sheet FUJITSU Server PRIMERGY CX400 M4 Scale out Server Data Sheet FUJITSU Server PRIMERGY CX400 M4 Scale out Server Workload-specific power in a modular form factor FUJITSU Server PRIMERGY will give

More information

PRIMERGY TX100 S2 Server

PRIMERGY TX100 S2 Server Operating Manual - English PRIMERGY TX100 S2 Server Operating Manual March 2011 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback

More information

Data Sheet FUJITSU Server PRIMERGY CX420 S1 Out-of-the-box Dual Node Cluster Server

Data Sheet FUJITSU Server PRIMERGY CX420 S1 Out-of-the-box Dual Node Cluster Server Data Sheet FUJITSU Server PRIMERGY CX420 S1 Out-of-the-box Dual Node Cluster Server Data Sheet FUJITSU Server PRIMERGY CX420 S1 Out-of-the-box Dual Node Cluster Server High availability for lower expertise

More information

User Guide Microsoft Portable Power (DC-21)

User Guide Microsoft Portable Power (DC-21) User Guide Microsoft Portable Power (DC-21) Issue 1.0 EN-US User Guide Microsoft Portable Power (DC-21) Contents For your safety 3 About your portable charger 4 Keys and parts 5 Charge your portable charger

More information

PRIMERGY TX300 S6 Server

PRIMERGY TX300 S6 Server Service Supplement - English PRIMERGY TX300 S6 Server Service Supplement Edition March 2010 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual.

More information

Bluetooth Hands-Free Speaker Phone Custom Accessories 23685

Bluetooth Hands-Free Speaker Phone Custom Accessories 23685 Bluetooth Hands-Free Speaker Phone Custom Accessories 23685 1. Product Description This versatile Bluetooth speakerphone is specially designed for the user to enjoy convenient and free wireless communication.

More information

Network Camera. Quick Guide DC-B1203X. Powered by

Network Camera. Quick Guide DC-B1203X. Powered by Network Camera Quick Guide DC-B1203X Powered by Safety Precautions English WARNING RISK OF ELECTRIC SHOCK DO NOT OPEN WARNING: TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER (OR BACK). NO USER-SERVICEABLE

More information

User Manual AIMB-C200. Economical Embedded Chassis for Mini-ITX Motherboard

User Manual AIMB-C200. Economical Embedded Chassis for Mini-ITX Motherboard User Manual AIMB-C200 Economical Embedded Chassis for Mini-ITX Motherboard Copyright The documentation and the software included with this product are copyrighted 2010 by Advantech Co., Ltd. All rights

More information

PRIMERGY RX300 S6 Server

PRIMERGY RX300 S6 Server Options Guide - English PRIMERGY RX300 S6 Server Options Guide Edition October 2012 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your

More information

OWC Mercury Helios 2 ASSEMBLY MANUAL & USER GUIDE

OWC Mercury Helios 2 ASSEMBLY MANUAL & USER GUIDE OWC Mercury Helios 2 ASSEMBLY MANUAL & USER GUIDE TABLE OF CONTENTS 1. INTRODUCTION...1 1.1 MINIMUM SYSTEM REQUIREMENTS 1.1.1 Apple Mac Requirements 1.1.2 PC Requirements 1.1.3 Supported PCIe Cards 1.2

More information

PRIMERGY TX200 S7 Server

PRIMERGY TX200 S7 Server Operating Manual - English PRIMERGY TX200 S7 Server Operating manual Edition June 2012 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual.

More information

PRIMERGY TX120 S2 Server. Operating manual

PRIMERGY TX120 S2 Server. Operating manual PRIMERGY TX120 S2 Server Operating manual Edition April 2009 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps us optimize

More information

Data Sheet FUJITSU Server PRIMERGY CX2550 M1 Dual Socket Server Node

Data Sheet FUJITSU Server PRIMERGY CX2550 M1 Dual Socket Server Node Data Sheet FUJITSU Server PRIMERGY CX2550 M1 Dual Socket Server Node Data Sheet FUJITSU Server PRIMERGY CX2550 M1 Dual Socket Server Node Standard server node for PRIMERGY CX400 M1 multi-node server system

More information

FUJITSU Server PRIMERGY RX2520 M1

FUJITSU Server PRIMERGY RX2520 M1 Operating Manual - English FUJITSU Server PRIMERGY RX2520 M1 Operating manual Edition February 2015 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of

More information

Read Me First. FUJITSU Storage ETERNUS CS800 S6. Table of Contents P3AM EN. ETERNUS CS800 S6 Manuals Package Contents...

Read Me First. FUJITSU Storage ETERNUS CS800 S6. Table of Contents P3AM EN. ETERNUS CS800 S6 Manuals Package Contents... FUJITSU Storage ETERNUS CS800 S6 Read Me First Fujitsu would like to thank you for purchasing our FUJITSU Storage ETERNUS CS800 S6 (hereinafter referred to as "ETERNUS CS800 S6"). Read this document and

More information

Emerson Network Power provides customers with technical support. Users may contact the nearest Emerson local sales office or service center.

Emerson Network Power provides customers with technical support. Users may contact the nearest Emerson local sales office or service center. Liebert PSA iton User Manual Version: V2.8 Revision date: November 14, 2005 Emerson Network Power provides customers with technical support. Users may contact the nearest Emerson local sales office or

More information

Fujitsu Cluster-in-a-box based on PRIMERGY BX400 PRIMERGY CX420 Windows Server 2012 R2 Edition

Fujitsu Cluster-in-a-box based on PRIMERGY BX400 PRIMERGY CX420 Windows Server 2012 R2 Edition User Guide - English Fujitsu Cluster-in-a-box based on PRIMERGY BX400 PRIMERGY CX420 Windows Server 2012 R2 Edition Getting Started Edition May 2014 Comments Suggestions Corrections The User Documentation

More information

Camera. Network Bullet Camera. Quick Operation Guide

Camera. Network Bullet Camera. Quick Operation Guide Camera Network Bullet Camera Quick Operation Guide 1 Thank you for purchasing our product. If there are any questions, or requests, please do not hesitate to contact the dealer. About This Document This

More information

Card Enrollment Station. User Manual UD05870B

Card Enrollment Station. User Manual UD05870B Card Enrollment Station User Manual UD05870B User Manual 2017 Hangzhou Hikvision Digital Technology Co., Ltd. This manual is applied for D8E series card enrollment station. It includes instructions on

More information

1. Product Description. 2. Product Overview

1. Product Description. 2. Product Overview 1. Product Description Avantree Pluto Air is a multi-function Bluetooth speaker with high quality music performance and mini compact design. This mini speaker can allow you to stream music from Bluetooth-enabled

More information

PRIMERGY RX200 S4 Server. Operating manual

PRIMERGY RX200 S4 Server. Operating manual PRIMERGY RX200 S4 Server Operating manual Edition January 2008 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps us

More information

HD40H(X) Performance Series Camera. User Guide

HD40H(X) Performance Series Camera. User Guide HD31H(X) HD30H(X) HD40H(X) Performance Series Camera User Guide Document 1 2 HD40H(X)/HD30H(X)/HD31H(X) Camera User Guide Thank you for purchasing our product. If there are any questions, or requests,

More information

PRIMERGY TX200 S3 Server. Operating Manual

PRIMERGY TX200 S3 Server. Operating Manual PRIMERGY TX200 S3 Server Operating Manual Edition June 2006 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps us optimize

More information

FCC COMPLICANCE STATEMENT

FCC COMPLICANCE STATEMENT FCC COMPLICANCE STATEMENT For Users in the USA This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of FCC Rules. These rules are designed

More information

Camera A14 and A34 Dome Camera

Camera A14 and A34 Dome Camera Camera A14 and A34 Dome Camera Quick Start Guide Thank you for purchasing our product. If there are any questions, or requests, please do not hesitate to contact the dealer. About This Manual: This manual

More information

PRIMERGY TX200 S4 Server. Operating manual

PRIMERGY TX200 S4 Server. Operating manual PRIMERGY TX200 S4 Server Operating manual Edition December 2007 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps us

More information

Data Sheet FUJITSU Server PRIMERGY CX400 M4 Scale out Server

Data Sheet FUJITSU Server PRIMERGY CX400 M4 Scale out Server Data Sheet FUJITSU Server PRIMERGY CX400 M4 Scale out Server Workload-specific power in a modular form factor FUJITSU Server PRIMERGY will give you the servers you need to power any workload and changing

More information

Dome Network Camera. Quick Start Guide

Dome Network Camera. Quick Start Guide Dome Network Camera Quick Start Guide Quick Start Guide ALL RIGHTS RESERVED Any and all information, including, among others, wordings, pictures, graphs are the properties of Hangzhou Hikvision Digital

More information

PRIMERGY RX300 S2 Server System

PRIMERGY RX300 S2 Server System PRIMERGY PRIMERGY RX300 S2 Server System Monika Spanjaart Fujitsu Siemens Computers GmbH München 81730 Munich e-mail: email: manuals@fujitsu-siemens.com Tel.: (089) 61001160 Fax: (++49) 700 / 372 00000

More information

This simple chassis houses one media-converter module and features an external AC power supply and also a terminal block for DC power input.

This simple chassis houses one media-converter module and features an external AC power supply and also a terminal block for DC power input. LMC5103A-R2 1-slot Multipower Desktop Chassis (Module Not Included) This simple chassis houses one media-converter module and features an external AC power supply and also a terminal block for DC power

More information

Obtaining Documentation and Submitting a Service Request, page xvii Safety Warnings, page xvii Safety Guidelines, page xx

Obtaining Documentation and Submitting a Service Request, page xvii Safety Warnings, page xvii Safety Guidelines, page xx Preface Obtaining Documentation and Submitting a Service Request, page xvii Safety s, page xvii Safety Guidelines, page xx Obtaining Documentation and Submitting a Service Request For information on obtaining

More information

VIS-3016 Fingerprint Recorder User Manual

VIS-3016 Fingerprint Recorder User Manual VIS-3016 Fingerprint Recorder User Manual www.visionistech.com User Manual About this Manual This manual is applied for fingerprint recorder. The Manual includes instructions for using and managing the

More information

PRIMERGY RX200 S5. Operating Manual

PRIMERGY RX200 S5. Operating Manual PRIMERGY RX200 S5 Operating Manual Edition April 2009 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps us optimize

More information

USER MANUAL. Uninterruptible Power Supply Line-interactive VCL Series UPS VA. GE Critical Power

USER MANUAL. Uninterruptible Power Supply Line-interactive VCL Series UPS VA. GE Critical Power Critical Power USER MANUAL Uninterruptible Power Supply Line-interactive VCL Series UPS 400 600 800 1000 1500 VA GE Consumer & Industrial SA General Electric Company CH 6595 Riazzino (Locarno) Switzerland

More information

Network Camera. Quick Guide DC-D1223WX. Powered by

Network Camera. Quick Guide DC-D1223WX. Powered by Network Camera Quick Guide DC-D1223WX Powered by Safety Precautions WARNING RISK OF ELECTRIC SHOCK DO NOT OPEN WARNING: TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER (OR BACK). NO USER-SERVICEABLE

More information

Chapter 1 Names and Functions This chapter explains the names and functions of the parts.

Chapter 1 Names and Functions This chapter explains the names and functions of the parts. PRIMERGY SX650 Storage Blade Hardware Guide Areas Covered Before Reading This Manual This section explains the notes for your safety and conventions used in this manual. Make sure to read before using

More information

Read Me First. FUJITSU Storage ETERNUS CS800 S7. Table of Contents P3AG EN. ETERNUS CS800 S7 Manuals Package Contents...

Read Me First. FUJITSU Storage ETERNUS CS800 S7. Table of Contents P3AG EN. ETERNUS CS800 S7 Manuals Package Contents... FUJITSU Storage ETERNUS CS800 S7 Read Me First Fujitsu would like to thank you for purchasing our FUJITSU Storage ETERNUS CS800 S7 (hereinafter referred to as "ETERNUS CS800 S7"). Read this document and

More information

16-SLOT IN-BAND MANAGEMENT CHASSIS

16-SLOT IN-BAND MANAGEMENT CHASSIS FCM-CHS2-XX 16-SLOT IN-BAND MANAGEMENT CHASSIS User's Guide. Version 1.6 FCC Warning This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15

More information

Data Sheet FUJITSU JX60 S2 DAS Subsystem

Data Sheet FUJITSU JX60 S2 DAS Subsystem Data Sheet FUJITSU JX60 S2 DAS Subsystem Data Sheet FUJITSU JX60 S2 DAS Subsystem High-capacity Direct Attached Storage (DAS) subsystem FUJITSU JX DAS Subsystem Data centers today are evolving, adopting

More information

PRIMERGY Econel 230R S1 Server. Operating manual

PRIMERGY Econel 230R S1 Server. Operating manual PRIMERGY Econel 230R S1 Server Operating manual Edition May 2007 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps us

More information

FZ-VEBG11x. Cradle. Model No. FZ-VEBG11 1. Model No. U Universal R China 1: Area U: Universal R: China

FZ-VEBG11x. Cradle. Model No. FZ-VEBG11 1. Model No. U Universal R China 1: Area U: Universal R: China ORDER NO. CPD1306201CE Cradle Model No. FZ-VEBG11x This is the Service Manual for the following areas. U for Universal R for China Model No. FZ-VEBG11 1 U Universal R China 1: Area U: Universal R: China

More information

PRIMERGY RX600 S5 Server

PRIMERGY RX600 S5 Server Options Guide - English PRIMERGY RX600 S5 Server Options Guide August 2012 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback

More information

PRIMERGY TX300 S3 Server. Operating Manual

PRIMERGY TX300 S3 Server. Operating Manual PRIMERGY TX300 S3 Server Operating Manual Edition July 2006 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps us optimize

More information

JanusRAID SA-6692J Hardware User Manual

JanusRAID SA-6692J Hardware User Manual JanusRAID SA-6692J Hardware User Manual 42-30000-5067 SATA II JBOD enclosure Version 1.1 SA-6692J SATA II JBOD enclosure Hardware User Manual Table of Contents Preface... i Chapter 1 System Requirements

More information

INSTRUCTION MANUAL DISTRIBUTION UNIT. Please read this manual thoroughly before use, and keep it handy for future reference.

INSTRUCTION MANUAL DISTRIBUTION UNIT. Please read this manual thoroughly before use, and keep it handy for future reference. INSTRUCTION MANUAL DISTRIBUTION UNIT Please read this manual thoroughly before use, and keep it handy for future reference. ISSUE 1 May 2006 LIMITATION OF LIABILITY THE INFORMATION IN THIS PUBLICATION

More information

PRIMERGY RX300 S4. Options Guide

PRIMERGY RX300 S4. Options Guide PRIMERGY RX300 S4 Options Guide Edition June 2008 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps us optimize our

More information

Table of Contents Quick Install Guide page Introduction Safety Rack System Precautions ESD Precautions...

Table of Contents Quick Install Guide page Introduction Safety Rack System Precautions ESD Precautions... Table of Contents Quick Install Guide page 1 EN English Table of Contents 1. Introduction... 2 1.1 Safety... 2 1.2 Rack System Precautions... 2-3 1.3 ESD Precautions... 3... 3 1... 3 2 Fitting PSU s...

More information

ZTE WIRELESS HOME PHONE BASE QUICK START GUIDE

ZTE WIRELESS HOME PHONE BASE QUICK START GUIDE ZTE WIRELESS HOME PHONE BASE QUICK START GUIDE Thank you for choosing Consumer Cellular! We know you re excited to use your new ZTE Wireless Home Phone Base, and this short guide will help you get familiar

More information

MC 11 EB-2 Power supply cabinet with external bus, AC version

MC 11 EB-2 Power supply cabinet with external bus, AC version MC 11 EB-2 Power supply cabinet with external bus, AC version USER/MAINTENANCE MANUAL 1 SLOT 0 SLOT 1 SLOT 2 SLOT 3 SLOT 4 SLOT 5 SLOT 6 SLOT 7 SLOT 8 SLOT 9 SLOT 10 SLOT 11 EB-2 (a) MC11 (b) (c) Figures

More information