PRIMERGY BX400 S1 System Unit

Size: px
Start display at page:

Download "PRIMERGY BX400 S1 System Unit"

Transcription

1 Options Guide - English PRIMERGY BX400 S1 System Unit Options Guide December 2010

2 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps us optimize our documentation to suit your individual needs. Feel free to send us your comments by to Certified documentation according to DIN EN ISO 9001:2008 To ensure a consistently high quality standard and user-friendliness, this documentation was created to meet the regulations of a quality management system which complies with the requirements of the standard DIN EN ISO 9001:2008. cognitas. Gesellschaft für Technik-Dokumentation mbh Copyright and Trademarks Copyright 2010 FUJITSU LIMITED All rights reserved. Delivery subject to availability; right of technical modifications reserved. All hardware and software names used are trademarks of their respective manufacturers. The contents of this manual may be revised without prior notice. Fujitsu assumes no liability for damages to third party copyrights or other rights arising from the use of any information in this manual. No part of this manual may be reproduced in any form without the prior written permission of Fujitsu. Microsoft, Windows, Windows Server, and Hyper V are trademarks or registered trademarks of Microsoft Corporation in the USA and other countries. Intel and Xeon are trademarks or registered trademarks of Intel Corporation or its subsidiaries in the USA and other countries.

3 Before reading this manual For your safety This manual contains important information for safely and correctly using this product. Carefully read the manual before using this product. Pay particular attention to the accompanying manual "Safety Notes and Regulations" and ensure these safety notes are understood before using the product. Keep this manual and the manual "Safety Notes and Regulations" in a safe place for easy reference while using this product. Radio interference This product is a "Class A" ITE (Information Technology Equipment). In a domestic environment this product may cause radio interference, in which case the user may be required to take appropriate measures. VCCI-A Aluminum electrolytic capacitors The aluminum electrolytic capacitors used in the product's printed circuit board assemblies and in the mouse and keyboard are limited-life components. Use of these components beyond their operating life may result in electrolyte leakage or depletion, potentially causing emission of foul odor or smoke. As a guideline, in a normal office environment (25 C) operating life is not expected to be reached within the maintenance support period (5 years). However, operating life may be reached more quickly if, for example, the product is used in a hot environment. The customer shall bear the cost of replacing replaceable components which have exceeded their operating life. Note that these are only guidelines, and do not constitute a guarantee of trouble-free operation during the maintenance support period. High safety use This product has been designed and manufactured to be used in commercial and/or industrial areas as a server. When used as visual display workplace, it must not be placed in the direct field of view to avoid incommoding reflections (applies only to TX server systems). The device has not been designed or manufactured for uses which demand an extremely high level of safety and carry a direct and serious risk of life or body if such safety cannot be assured. BX400 S1 Options Guide

4 These uses include control of nuclear reactions in nuclear power plants, automatic airplane flight control, air traffic control, traffic control in mass transport systems, medical devices for life support, and missile guidance control in weapons systems (hereafter, "high safety use"). Customers should not use this product for high safety use unless measures are in place for ensuring the level of safety demanded of such use. Please consult the sales staff of Fujitsu if intending to use this product for high safety use. Measures against momentary voltage drop This product may be affected by a momentary voltage drop in the power supply caused by lightning. To prevent a momentary voltage drop, use of an AC uninterruptible power supply is recommended. (This notice follows the guidelines of Voltage Dip Immunity of Personal Computer issued by JEITA, the Japan Electronics and Information Technology Industries Association.) Technology controlled by the Foreign Exchange and Foreign Trade Control Law of Japan Documents produced by Fujitsu may contain technology controlled by the Foreign Exchange and Foreign Trade Control Law of Japan. Documents which contain such technology should not be exported from Japan or transferred to non-residents of Japan without first obtaining authorization in accordance with the above law. Harmonic Current Standards This product conforms to harmonic current standard JIS C Only for the Japanese market: About SATA hard disk drives The SATA version of this server supports hard disk drives with SATA / BC-SATA storage interfaces. Please note that the usage and operation conditions differ depending on the type of hard disk drive used. Please refer to the following internet address for further information on the usage and operation conditions of each available type of hard disk drive: Options Guide BX400 S1

5 Contents 1 Introduction Concept and target groups Documentation overview Expansions and upgrades Notational conventions Procedure Safety instructions Preparation Floorstand model Opening the system unit Rack model Optical Disk Drive (ODD) Rack model Floorstand model ServerView Local Service Display for Blade Conversion from a rack model to a floorstand model Completion Floorstand model BX400 S1 Options Guide

6 Contents 8.2 Rack model Index Options Guide BX400 S1

7 1 Introduction The PRIMERGY BX400 S1 blade server is a highly compact, energy-saving and scalable server system. With its advanced infrastructure modules, the BX400 S1 system unit offers the server blades a high level of connectivity and availability. It is available as a rack or floorstand model. The rack model can be converted to a floorstand model using an optional conversion kit. 1.1 Concept and target groups This Options Guide shows you how to extend and upgrade your system unit. V CAUTION! The activities described in this manual may only be performed by technical specialists. I The installation and removal of the hot-plug components is described in the Operating Manual supplied with the system unit. 1.2 Documentation overview More information on your PRIMERGY BX400 S1 system unit can be found in the following documents: "Quick Start Hardware - PRIMERGY BX400 S1" leaflet " はじめにお読みください -PRIMERGY BX400 S1" for the Japanese market (only included as a printed copy) "Safety Notes and Regulations" manual " 安全上のご注意 " for the Japanese market "Warranty" manual " 保証書 " for the Japanese market "ServerView Suite Local Service Concept - LSC" manual "Returning used devices" manual and "Service Desk" leaflet " サポート & サービス " for the Japanese market "PRIMERGY BX400 S1 Blade Server System Unit Operating Manual" "PRIMERGY BX400 S1 System Unit Options Guide" BX400 S1 Options Guide 7

8 Introduction I PRIMERGY manuals are available in PDF format on the ServerView Suite DVD 2. The ServerView Suite DVD 2 is part of the ServerView Suite supplied with every server. If you no longer have the ServerView Suite DVDs, you can obtain the relevant current versions using the order number U15000-C289 (the order number for the Japanese market: please refer to the configurator of the server The PDF files of the manuals can also be downloaded free of charge from the Internet. The overview page showing the online documentation available on the Internet can be found using the URL (for EMEA market): The PRIMERGY server documentation can be accessed using the Industry standard servers navigation option. For the Japanese market please use the URL: Further sources of information: PRIMERGY Abbreviations and Glossary on the ServerView Suite DVD 2 Manual for the monitor Documentation for the boards and drives Operating system documentation Information files in your operating system 8 Options Guide BX400 S1

9 Introduction 1.3 Expansions and upgrades Accessible drive One bay is available for an optical disk drive (ODD) (DVD or Blue-ray). It is located on the upper front bezel (rack model) or on the Front-Side I/O Module (FSIOM) (floorstand model). ServerView Local Service Display for Blade You can install a ServerView Local Service Display for Blade instead of a front control panel for local administration and easier identification of defective components (rack model). The floorstand model is factory equipped with the ServerView Local Service Display for Blade. Conversion from a rack model to a floorstand model The rack model can be optionally converted to floorstand model using a conversion kit. 1.4 Notational conventions The following notational conventions are used in this manual: Text in italics "Quotation marks" V CAUTION! I indicates commands or menu items. indicate names of chapters and terms that are being emphasized. describes activities that must be performed in the order shown. pay particular attention to texts marked with this symbol. Failure to observe this warning may endanger your life, destroy the system or lead to the loss of data. indicates additional information, notes and tips. BX400 S1 Options Guide 9

10 Introduction 10 Options Guide BX400 S1

11 2 Procedure V CAUTION! The actions described in this manual shall be performed by technical specialists. A technical specialist is a person who is trained to install the server including hardware and software. Repairs to the device that do not relate to CSS failures shall be performed by service personnel. Please note that unauthorized interference with the system will void the warranty and exempt the manufacturer from all liability. Any failure to observe the guidelines in this manual, and any improper repairs could expose the user to risks (electric shock, energy hazards, fire hazards) or damage the equipment. First of all, carefully read the safety instructions in the chapter "Safety instructions" on page 13. Make sure that all necessary manuals (see the section "Documentation overview" on page 7) are available; print the PDF files if required. Most importantly, you will need the Operating Manual for the system unit. Shut the system unit down correctly and disconnect the power cords and open the system unit as described in the chapter "Preparation" on page 21. Carry out the expansion or upgrade of your system unit as described in the pertinent chapter. I Installation and removal of the hot-plug components are described in the Operating Manual. Close the system unit, connect it to the power outlet, and switch it on as described in the chapter "Completion" on page 57. Start the operating system and make the appropriate configuration if necessary (see the Operating Manual of the server blade). I For the latest information on optional products provided for the BX400 S1 system unit see the configurator of the system unit: (for the EMEA market) (for the Japanese market) BX400 S1 Options Guide 11

12 Procedure 12 Options Guide BX400 S1

13 3 Safety instructions I The following safety instructions are also provided in the manual "Safety Notes and Regulations" or " 安全上のご注意 ". This device meets the relevant safety regulations for IT equipment. If you have any questions about whether you can install the server in the intended environment, please contact your sales outlet or our customer service team. V CAUTION! The actions described in this manual shall be performed by technical specialists. A technical specialist is a person who is trained to install the server including hardware and software. Repairs to the device that do not relate to CSS failures shall be performed by service personnel. Please note that unauthorized interference with the system will void the warranty and exempt the manufacturer from all liability. Any failure to observe the guidelines in this manual, and any improper repairs could expose the user to risks (electric shock, energy hazards, fire hazards) or damage the equipment. Before installing/removing internal options to/from the server, turn off the server, all peripheral devices, and any other connected devices. Also unplug all power cords from the power outlet. Failure to do so can cause electric shock. BX400 S1 Options Guide 13

14 Safety instructions Before starting up V CAUTION! During installation and before operating the device, observe the instructions on environmental conditions for your device. If the device is brought in from a cold environment, condensation may form both inside and on the outside of the device. Wait until the device has acclimatized to room temperature and is absolutely dry before starting it up. Material damage may be caused to the device if this requirement is not observed. Transport the device only in the original packaging or in packaging that protects it from knocks and jolts. Installation and operation V CAUTION! This unit should not be operated in ambient temperatures above 35 C. If the unit is integrated into an installation that draws power from an industrial power supply network with an IEC309 connector, the power supply's fuse protection must comply with the requirements for nonindustrial power supply networks for type A connectors. The unit automatically adjusts itself to a mains voltage in a range of 100 V V. Ensure that the local mains voltage lies within these limits. This device must only be connected to properly grounded power outlets or insulated sockets of the rack's internal power supply with tested and approved power cords. Ensure that the device is connected to a properly grounded power outlet close to the device. 14 Options Guide BX400 S1

15 Safety instructions V CAUTION! Ensure that the power sockets on the device and the properly grounded power outlets are freely accessible. The On/Off button or the main power switch (if present) does not isolate the device from the mains power supply. To disconnect it completely from the mains power supply, unplug all network power plugs from the properly grounded power outlets. Always connect the server and the attached peripherals to the same power circuit. Otherwise you run the risk of losing data if, for example, the server is still running but a peripheral device (e.g. memory subsystem) fails during a power outage. Data cables must be adequately shielded. Ethernet cabling has to comply with EN and EN /2 standards or ISO/IEC standard respectively. The minimum requirement is a Category 5 shielded cable for 10/100 Ethernet, or a Category 5e cable for Gigabit Ethernet. Route the cables in such a way that they do not create a potential hazard (make sure no-one can trip over them) and that they cannot be damaged. When connecting the server, refer to the relevant instructions in this manual. Never connect or disconnect data transmission lines during a storm (risk of lightning hazard). Make sure that no objects (e.g. jewelry, paperclips etc.) or liquids can get inside the server (risk of electric shock, short circuit). In emergencies (e.g. damaged casing, controls or cables, penetration of liquids or foreign bodies), switch off the server immediately, remove all power plugs and contact your sales outlet or customer service team. BX400 S1 Options Guide 15

16 Safety instructions V CAUTION! Proper operation of the system (in accordance with IEC /2 resp. EN /2) is only ensured if the casing is completely assembled and the rear covers for the installation slots have been fitted (electric shock, cooling, fire protection, interference suppression). Only install system expansions that satisfy the requirements and rules governing safety and electromagnetic compatibility and those relating to telecommunication terminals. If you install other expansions, they may damage the system or violate the safety regulations. Information on which system expansions are approved for installation can be obtained from our customer service center or your sales outlet. The components marked with a warning notice (e.g. lightning symbol) may only be opened, removed or exchanged by authorized, qualified personnel. Exception: CSS components can be replaced. The warranty is void if the server is damaged during installation or replacement of system expansions. Only set screen resolutions and refresh rates that are specified in the operating manual for the monitor. Otherwise, you may damage your monitor. If you are in any doubt, contact your sales outlet or customer service center. Before installing/removing internal options to/from the server, turn off the server, all peripheral devices, and any other connected devices. Also unplug all power cords from the outlet. Failure to do so can cause electric shock. Do not damage or modify internal cables or devices. Doing so may cause a device failure, fire, or electric shock. Devices inside the server remain hot after shutdown. Wait for a while after shutdown before installing or removing internal options. The circuit boards and soldered parts of internal options are exposed and can be damaged by static electricity. Before handling them, first touch a metal part of the server to discharge static electricity from your body. Do not touch the circuitry on boards or soldered parts. Hold the metallic areas or the edges of the circuit boards. 16 Options Guide BX400 S1

17 Safety instructions V CAUTION! Install the screw removed during installation/detaching Internal Options in former device/position. To use a screw of the different kind causes a breakdown of equipment. The installation indicated on this note is sometimes changed to the kind of possible options without notice. BX400 S1 Options Guide 17

18 Safety instructions Working with CDs/DVDs/BDs and optical drives When working with devices with optical drives, these instructions must be followed. V CAUTION! Only use CDs/DVDs/BDs that are in perfect condition, in order to prevent data loss, equipment damage and injury. Check each CD/DVD/BD for damage, cracks, breakages etc. before inserting it in the drive. Note that any additional labels applied may change the mechanical properties of a CD/DVD/BD and cause imbalance. Damaged and imbalanced CDs/DVDs/BDs can break at high drive speeds (data loss). Under certain circumstances, sharp CD/DVD/BD fragments can pierce the cover of the optical drive (equipment damage) and can fly out of the device (danger of injury, particularly to uncovered body parts such as the face or neck). High humidity and airborne dust levels are to be avoided. Electric shocks and/or server failures may be caused by liquids such as water, or metallic items, such as paper clips, entering a drive. Shocks and vibrations are also to be avoided. Do not insert any objects other than the specified CDs/DVDs/BDs. Do not pull on, press hard, or otherwise handle the CD/DVD/BD tray roughly. Do not disassemble the optical drive. Before use, clean the optical disk tray using a soft, dry cloth. As a precaution, remove disks from the optical drive when the drive is not to be used for a long time. Keep the optical disk tray closed to prevent foreign matter, such as dust, from entering the optical drive. Hold CDs/DVDs/BDs by their edges to avoid contact with the disk surface. 18 Options Guide BX400 S1

19 Safety instructions Do not contaminate the CD/DVD/BD surface with fingerprints, oil, dust, etc. If dirty, clean with a soft, dry cloth, wiping from the center to the edge. Do not use benzene, thinners, water, record sprays, antistatic agents, or silicone-impregnated cloth. Be careful not to damage the CD/DVD/BD surface. Keep the CDs/DVDs/BDs away from heat sources. Do not bend or place heavy objects on CDs/DVDs/BDs. Do not write with ballpoint pen or pencil on the label (printed) side. Do not attach stickers or similar to the label side. Doing so may cause rotational eccentricity and abnormal vibrations. When a CD/DVD/BD is moved from a cold place to a warm place, moisture condensation on the CD/DVD/BD surface can cause data read errors. In this case, wipe the CD/DVD/BD with a soft, dry cloth then let it air dry. Do not dry the CD/DVD/BD using devices such as a hair dryer. To avoid dust, damage, and deformation, keep the CD/DVD/BD in its case whenever it is not in use. Do not store CDs/DVDs/BDs at high temperatures. Areas exposed to prolonged direct sunlight or near heating appliances are to be avoided. I You can prevent damage from the optical drive and the CDs/DVDs/BDs, as well as premature wear of the disks, by observing the following suggestions: Only insert disks in the drive when needed and remove them after use. Store the disks in suitable sleeves. Protect the disks from exposure to heat and direct sunlight. Laser information The optical drive complies with IEC laser class 1. V CAUTION! The optical drive contains a light-emitting diode (LED), which under certain circumstances produces a laser beam stronger than laser class 1. Looking directly at this beam is dangerous. Never remove parts of the optical drive casing! BX400 S1 Options Guide 19

20 Safety instructions Modules with Electrostatic-Sensitive Devices Modules with electrostatic-sensitive devices are identified by the following sticker: Figure 1: ESD label When you handle components fitted with ESDs, you must always observe the following points: Switch off the system and remove the power plugs from the power outlets before installing or removing components with ESDs. You must always discharge static build-up (e.g. by touching a grounded object) before working with such components. Any devices or tools that are used must be free of electrostatic charge. Wear a suitable grounding cable that connects you to the external chassis of the system unit. Always hold components with ESDs at the edges or at the points marked green (touch points). Do not touch any connectors or conduction paths on an ESD. Place all the components on a pad which is free of electrostatic charge. I For a detailed description of how to handle ESD components, see the relevant European or international standards (EN , ANSI/ESD S20.20). 20 Options Guide BX400 S1

21 4 Preparation V CAUTION! Follow the safety instructions in the chapter "Safety instructions" on page Floorstand model Opening the system unit Terminate all applications and shut down the system unit correctly. If your operating system has not switched off the server, press the On/Off button. Pull all power cables out of the power outlet. Unlock the door and remove the key. Figure 2: Removing the door Pull the hinge pin (see circle) downward and remove the door. BX400 S1 Options Guide 21

22 Preparation 4.2 Rack model Terminate all applications and shut down the system unit correctly. If your operating system has not switched off the server, press the On/Off button. Pull all power cables out of the power outlet. 22 Options Guide BX400 S1

23 5 Optical Disk Drive (ODD) V CAUTION! When installing the ODD, hold it by the side. Applying force to the top may cause failures. Follow the safety instructions in the chapter "Safety instructions" on page 13. Figure 3: Preparing the ODD Fasten the engaging hook on the ODD. BX400 S1 Options Guide 23

24 Optical Disk Drive (ODD) 5.1 Rack model The ODD mounting bay is located on the upper front bezel of the system unit. Empty the sever blade slots 7 and 8. See the Operating Manual for how to remove server blades, storage blades and server blade dummy modules. Figure 4: Removing the ODD dummy module Press the green engaging hook up (1) and to the front side of the system unit (2) to remove the ODD dummy module. 24 Options Guide BX400 S1

25 Optical Disk Drive (ODD) Figure 5: Inserting the ODD Push the ODD in the bay of the system unit until it engages. Reinstall server blades, storage blades or server blade dummy modules in slots 7 and 8, see the Operating Manual. Connect the system unit to the power outlet, and switch it on as described in the chapter "Completion" on page 57. BX400 S1 Options Guide 25

26 Optical Disk Drive (ODD) 5.2 Floorstand model The ODD mounting bay is located on the FSIOM. Empty the sever blade slots 7 and 8. See the Operating Manual for how to remove server blades, storage blades and server blade dummy modules. Figure 6: Disengaging the FSIOM Disengage the lock of the FSIOM (1) and pull it out of the system unit up to the stop (2) I If the FSIOM is hard to unlock, press it at the left front (vicinity of server blade slots 7 and 8) as you release it. 26 Options Guide BX400 S1

27 Optical Disk Drive (ODD) Figure 7: Removing the FSIOM Disconnect the door sensor cable (small circle) and the LCD cable (large circle) from the FSIOM. Unlock the FSIOM (1) and pull it out of the system unit completely (2). Figure 8: Removing the ODD dummy module from the FSIOM Unlock the ODD dummy module (1) and remove it from the FSIOM (2). BX400 S1 Options Guide 27

28 Optical Disk Drive (ODD) Figure 9: Inserting the ODD in the FSIOM Push the ODD into the bay of the FSIOM until the engaging hook (1) under the metal holder (2) locks in place. Figure 10: Connecting the SATA cable to the ODD Connect the other plug of the SATA cable to the port on the ODD (see circle) and put the cable in the cable clamp (1). 28 Options Guide BX400 S1

29 Optical Disk Drive (ODD) Figure 11: Connecting the door sensor cable and the LCD cable to the FSIOM Push the FSIOM into the system unit until the security lock engages. Connect the door sensor cable (small circle) and the LCD cable (large circle) to the FSIOM. Disengage the security lock of the FSIOM (1) and push it completely into the system unit (2). The FSIOM clicks into place in its final position. Reinstall server blades, storage blades or server blade dummy modules in slots 7 and 8, see the Operating Manual. Connect the system unit to the power outlet, and switch it on as described in the chapter "Completion" on page 57. BX400 S1 Options Guide 29

30 Optical Disk Drive (ODD) 30 Options Guide BX400 S1

31 6 ServerView Local Service Display for Blade V CAUTION! Follow the safety instructions in the chapter "Safety instructions" on page 13. Figure 12: Front control panel The ServerView Local Service Display for Blade is an option in the rack model of the BX400 S1 system unit. The ServerView Local Service Display for Blade is placed in the FSIOM instead of the front control panel. I The floorstand model is factory equipped with the ServerView Local Service Display for Blade. Empty the sever blade slots 7 and 8. See the Operating Manual for how to remove server blades, storage blades and server blade dummy modules. BX400 S1 Options Guide 31

32 ServerView Local Service Display for Blade Figure 13: Disengaging the FSIOM Disengage the lock of the FSIOM (1) and pull it out of the system unit up to the stop (2). I If the FSIOM is hard to unlock, press it at the top front as you release it. 32 Options Guide BX400 S1

33 ServerView Local Service Display for Blade Figure 14: Removing the FSIOM Unplug the SATA cable (1). Unlock the FSIOM (2) and pull it out of the system unit completely. Figure 15: Removing the front control panel carrier from the FSIOM Unplug the LCD cable from the front control panel (see circle). Unlock the carrier of the front control panel (1) and remove it from the FSIOM (2). BX400 S1 Options Guide 33

34 ServerView Local Service Display for Blade Figure 16: Removing the front control panel from the carrier Remove the stopper from the carrier. To do this, loosen the screw (1) and push the stopper (2) out. Remove the front control panel from the carrier (3). Figure 17: Inserting the ServerView Local Service Display for Blade into the carrier Push the ServerView Local Service Display for Blade into the carrier and secure the stopper with the screw again. 34 Options Guide BX400 S1

35 ServerView Local Service Display for Blade Figure 18: Inserting the carrier into the FSIOM Push the carrier all the way to the stop into the FSIOM (1). In this position the lock engages (2). Disengage the locking mechanism of the ServerView Local Service Display for Blade (3) and slide it completely into the FSIOM. Figure 19: Inserting the carrier into the FSIOM Place the LCD cable in the cable reel (1). Connect the LCD cable (see circle). BX400 S1 Options Guide 35

36 ServerView Local Service Display for Blade Figure 20: Inserting the carrier into the FSIOM Push the FSIOM into the system unit until the security lock engages. Connect the SATA cable (see circle). Disengage the security lock of the FSIOM (1) and push it completely into the system unit (2). The FSIOM clicks into place in its final position. Reinstall server blades, storage blades or server blade dummy modules, see the Operating Manual. Connect the system unit to the power outlet, and switch it on as described in the chapter "Completion" on page Options Guide BX400 S1

37 7 Conversion from a rack model to a floorstand model V CAUTION! Follow the safety instructions in the chapter "Safety instructions" on page 13. The rack model can be optionally converted to floorstand model using a conversion kit. Make a note of the positions of the individual server blades and storage blades, the connection blades, power supply units, fan units and management blades in the system unit for reinstallation. Remove the server blades, storage blades, power supply units, fan units, connection blades and management blades from the system unit. For assembly instructions see the Operating Manual. Removing the ODD or ODD dummy module Figure 21: Removing the ODD Press the green engaging hook up (1) and to the front side of the system unit (2) to remove the ODD or the ODD dummy module. BX400 S1 Options Guide 37

38 Conversion from a rack model to a floorstand model Store the ODD or ODD dummy module in a safe place. You will need it for installing on the FSIOM later on. Removing the handles bars Figure 22: Removing the handle bars Loosen the four countersunk screws on either side to remove the handle bars. 38 Options Guide BX400 S1

39 Conversion from a rack model to a floorstand model Removing the ID card Figure 23: Pulling the ID card up to the stop Pull the ID card out of the system unit up to the stop. Figure 24: Removing the ID card Press the the engaging lug (1) as you pull the ID card out of the system unit (2). BX400 S1 Options Guide 39

40 Conversion from a rack model to a floorstand model Removing the FSIOM Figure 25: Disengaging the FSIOM Disengage the lock of the FSIOM (1) and pull it out of the system unit up to the stop (2) I If the FSIOM is hard to unlock, press it at the top front as you release it. 40 Options Guide BX400 S1

41 Conversion from a rack model to a floorstand model Figure 26: Removing the FSIOM Unplug the SATA cable (1). Unlock the FSIOM (2) and pull it out of the system unit completely. BX400 S1 Options Guide 41

42 Conversion from a rack model to a floorstand model Removing the SATA cable Detach the SATA cable from the cable guides inside the FSIOM bay (see arrows). Figure 27: Removing the SATA cable 42 Options Guide BX400 S1

43 Conversion from a rack model to a floorstand model Figure 28: Opening the cable channel Remove the cover above the cable channel on top of the system unit by loosening the two countersunk screws (see circles). Figure 29: Removing the SATA cable Detach the plug from the fixing pins (see circles). Detach the cable from the cable guides (see arrows). Carefully pull out the other end of the cable of the hole in the system unit. Store the cable in a safe place. You will need it for the connection of the ODD on the FSIOM later on. BX400 S1 Options Guide 43

44 Conversion from a rack model to a floorstand model Removing the front control panel Figure 30: Removing the front control panel from the FSIOM Unplug the LCD cable from the front control panel and from the FSIOM (see circles) and remove the LCD cable by detaching the cable clamp. Unlock the carrier of the front control panel (1) and remove it from the FSIOM (2). I Carrier, front control panel and LCD cable are no longer required. I When a ServerView Local Service Display for Blade is installed in your system unit, you must remove it in the same way as the front control panel. 44 Options Guide BX400 S1

45 Conversion from a rack model to a floorstand model Installing the ODD Figure 31: Inserting the ODD in the FSIOM Push the ODD into the bay of the FSIOM until the engaging hook (1) under the metal holder (2) locks in place. Figure 32: Connecting the SATA cable to the FSIOM Connect the bent plug of the SATA cable you obtained to the port on the system board (see circle). BX400 S1 Options Guide 45

46 Conversion from a rack model to a floorstand model Figure 33: Connecting the SATA cable to the ODD Connect the other plug of the SATA cable to the port on the ODD (see circle) and put the cable in the cable clamp (1). 46 Options Guide BX400 S1

47 Conversion from a rack model to a floorstand model Replacing the sidebars Turn the system unit through 90 to the right so that the bay of the FSIOM is on the bottom. V CAUTION! Get a second person to help you do this. The PRIMERGY BX400 S1 system unit is large and heavy. Figure 34: Removing the rack model sidebars Remove the sidebars of the rack variant by loosening four countersunk screws on both sides. Keep the screws for the fastening of the floorstand sidebars. BX400 S1 Options Guide 47

48 Conversion from a rack model to a floorstand model Figure 35: Attaching the floorstand sidebars Attach the floorstand sidebars with the countersunk screws you obtained with the removal of the sidebars of the rack model. 48 Options Guide BX400 S1

49 Conversion from a rack model to a floorstand model Securing the floor unit Figure 36: Fastening the floor unit Secure the floor unit on the underside with the six provided screws (see circles). V CAUTION! When fastening the four screws (see red circles), be careful that they do not fall into the hollow spaces of the castor support braces. Put the system unit through 180 in the upright position. V CAUTION! Get a second person to help you do this. The PRIMERGY BX400 S1 system unit is large and heavy. BX400 S1 Options Guide 49

50 Conversion from a rack model to a floorstand model Securing the top cover module Figure 37: Engaging hooks of the top cover module The top cover module is equipped with engaging hooks on both sides (see circles) for the anchoring on the housing of the system unit. Figure 38: Oblong holes in the housing of the system unit In the figure above, the oblong holes in the housing of the system unit for the application of the engaging hooks of the top cover module are indicated by circles. Place the top cover module on the housing of the system unit so that the engaging hooks interlock with the oblong holes on both sides. 50 Options Guide BX400 S1

51 Conversion from a rack model to a floorstand model Figure 39: Fastening the top cover module Push the top cover module backward as far as it will go. Secure the top cover module on both sides with countersunk screws (see circle). BX400 S1 Options Guide 51

52 Conversion from a rack model to a floorstand model Inserting the ID Card Figure 40: Inserting the ID card Insert the ID Card in the slot provided on the ServerView Local Service Display for Blade. Routing cables Figure 41: Routing the cables Thread the cables through the hole in the housing of the system unit (see arrow). 52 Options Guide BX400 S1

53 Conversion from a rack model to a floorstand model Figure 42: Routing the LCD cable Route the cables under the guides as shown in the figure (see arrows). Figure 43: Closing the cable channel Insert the slot cover above the cable channel and secure it with the two countersunk screws you obtained with the removal (see circles). BX400 S1 Options Guide 53

54 Conversion from a rack model to a floorstand model Installing the FSIOM Figure 44: Connecting the door sensor cable and the LCD cable to the FSIOM Push the FSIOM into the system unit until the security lock engages. Connect the door sensor cable (small circle) and the LCD cable (large circle) to the FSIOM. Disengage the security lock of the FSIOM (1) and push it completely into the system unit (2). The FSIOM clicks into place in its final position. 54 Options Guide BX400 S1

55 Conversion from a rack model to a floorstand model Securing the side covers Figure 45: Side cover fastening arrangements Place the left side cover on the three metal brackets (see arrows) and hook the side cover in the eight t-profile pins (see circles). BX400 S1 Options Guide 55

56 Conversion from a rack model to a floorstand model Figure 46: Fastening the side cover Push the side cover completely backward and secure it with the provided screw (see circle). Secure the right side cover in the same way. Reinstall the server blades, storage blades, power supply units, fan units, connection blades and management blades, see the Operating Manual. Connect the system unit to the power outlet, and switch it on as described in the chapter "Completion" on page Options Guide BX400 S1

57 8 Completion V CAUTION! Follow the safety instructions in the chapter "Safety instructions" on page Floorstand model Figure 47: Inserting the door Insert the hinge hole of the door (1) in the hinge pin (2). BX400 S1 Options Guide 57

58 Completion Figure 48: Positioning the door hinge pin Pull the hinge pin downward (1) and position it in the hinge hole in the cover plate (2). Insert the key. Lock the door. Connect all power plugs to the power outlets. Press the On/Off button to start up the system unit. 8.2 Rack model Connect all cables on the rear of the server. Connect all power plugs to the power outlets. Press the On/Off button to start up the system unit. 58 Options Guide BX400 S1

59 Index A accessible drives 9 C conversion of floorstand model to rack model 9, 37 D door sensor cable 27, 29 E electrostatic-sensitive devices (ESD) 20 F front control panel 31 Front-Side I/O Module (FSIOM) 33 I information, additional 8 L laser information 19 LCD cable 27, 29 light emitting diode (LED) 19 Local Service Display 9, 31 LSB 9, 31 M meaning of the symbols 9 N notational conventions 9 O ODD 23 ODD dummy module 27 optical disk drive 23 T target group 7 BX400 S1 Options Guide 59

60 Index 60 Options Guide BX400 S1

Operating Manual - English. RDX USB 3.0 QuikStor Drive

Operating Manual - English. RDX USB 3.0 QuikStor Drive Operating Manual - English RDX USB 3.0 QuikStor Drive December 2017 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps

More information

PRIMERGY TX120 S2 Server. Service Supplement

PRIMERGY TX120 S2 Server. Service Supplement PRIMERGY TX120 S2 Server Service Supplement Edition July 2009 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps us optimize

More information

PRIMERGY TX300 S6 Server

PRIMERGY TX300 S6 Server Service Supplement - English PRIMERGY TX300 S6 Server Service Supplement Edition March 2010 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual.

More information

FUJITSU Server PRIMERGY RX1330 M2

FUJITSU Server PRIMERGY RX1330 M2 Upgrade and Maintenance Manual - English FUJITSU Server PRIMERGY RX1330 M2 Upgrade and Maintenance Manual December 2015 Comments Suggestions Corrections The User Documentation Department would like to

More information

FUJITSU Server PRIMERGY RX1330 M1

FUJITSU Server PRIMERGY RX1330 M1 Upgrade and Maintenance Manual - English FUJITSU Server PRIMERGY RX1330 M1 Upgrade and Maintenance Manual August 2014 Comments Suggestions Corrections The User Documentation Department would like to know

More information

PRIMERGY CX400 S1 Server Enclosure

PRIMERGY CX400 S1 Server Enclosure Upgrade and Maintenance Manual - English PRIMERGY CX400 S1 Server Enclosure Upgrade and Maintenance Manual Edition December 2012 Comments Suggestions Corrections The User Documentation Department would

More information

PRIMERGY BX920 S3 Server Blade

PRIMERGY BX920 S3 Server Blade Upgrade and Maintenance Manual - English PRIMERGY BX920 S3 Server Blade Upgrade and Maintenance Manual Edition February 2014 Comments Suggestions Corrections The User Documentation Department would like

More information

PRIMERGY RX300 S6 Server

PRIMERGY RX300 S6 Server Options Guide - English PRIMERGY RX300 S6 Server Options Guide Edition October 2012 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your

More information

PRIMERGY RX600 S5 Server

PRIMERGY RX600 S5 Server Options Guide - English PRIMERGY RX600 S5 Server Options Guide August 2012 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback

More information

PRIMERGY CX400 S2 Server Enclosure

PRIMERGY CX400 S2 Server Enclosure Operating Manual - English PRIMERGY CX400 S2 Server Enclosure Operating Manual Edition December 2013 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of

More information

PRIMERGY MX130 S2 Server

PRIMERGY MX130 S2 Server Upgrade and Maintenance Manual - English PRIMERGY MX130 S2 Server Upgrade and Maintenance Manual Edition November 2011 Comments Suggestions Corrections The User Documentation Department would like to know

More information

PRIMERGY BX922 S2 Server Blade

PRIMERGY BX922 S2 Server Blade Options Guide - us PRIMERGY BX922 S2 Server Blade Options Guide Edition March 2011 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your

More information

FUJITSU Server PRIMERGY TX1320 M3

FUJITSU Server PRIMERGY TX1320 M3 Upgrade and Maintenance Manual - English FUJITSU Server PRIMERGY TX1320 M3 Upgrade and Maintenance Manual April 2017 Comments Suggestions Corrections The User Documentation Department would like to know

More information

PRIMERGY RX100 S6 Server

PRIMERGY RX100 S6 Server Options Guide - English PRIMERGY RX100 S6 Server Options Guide Edition June 2012 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your

More information

FUJITSU Server PRIMERGY RX100 S8

FUJITSU Server PRIMERGY RX100 S8 Upgrade and Maintenance Manual - English FUJITSU Server PRIMERGY RX100 S8 Upgrade and Maintenance Manual April 2015 Comments Suggestions Corrections The User Documentation Department would like to know

More information

PRIMERGY TX200 S6 Server

PRIMERGY TX200 S6 Server Options Guide - English PRIMERGY TX200 S6 Server Options Guide Edition July 2010 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your

More information

PRIMERGY SX940 S1 Storage Blade

PRIMERGY SX940 S1 Storage Blade Operating manual - English PRIMERGY SX940 S1 Storage Blade Operating manual Edition March 2011 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this

More information

PRIMERGY TX150 S6 Server. Options Guide

PRIMERGY TX150 S6 Server. Options Guide PRIMERGY TX150 S6 Server Options Guide Edition June 2009 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps us optimize

More information

PRIMERGY BX620 S6 Server Blade

PRIMERGY BX620 S6 Server Blade Service Supplement - English PRIMERGY BX620 S6 Server Blade Service Supplement September 2010 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this

More information

PRIMERGY RX600 S5 Server

PRIMERGY RX600 S5 Server Service Supplement - English PRIMERGY RX600 S5 Server Service Supplement June 2010 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your

More information

PRIMERGY TX300 S6 Server

PRIMERGY TX300 S6 Server Options Guide - English PRIMERGY TX300 S6 Server Options Guide Edition March 2010 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your

More information

FUJITSU Server PRIMERGY RX2510 M2

FUJITSU Server PRIMERGY RX2510 M2 Upgrade and Maintenance Manual - English FUJITSU Server PRIMERGY RX2510 M2 Upgrade and Maintenance Manual June 2017 Comments Suggestions Corrections The User Documentation Department would like to know

More information

FUJITSU Server PRIMERGY RX1330 M3

FUJITSU Server PRIMERGY RX1330 M3 Upgrade and Maintenance Manual - English FUJITSU Server PRIMERGY RX1330 M3 Upgrade and Maintenance Manual April 2017 Comments Suggestions Corrections The User Documentation Department would like to know

More information

PRIMERGY CX272 S1 Server Node

PRIMERGY CX272 S1 Server Node Upgrade and Maintenance Manual - English PRIMERGY CX272 S1 Server Node Upgrade and Maintenance Manual February 2014 Comments Suggestions Corrections The User Documentation Department would like to know

More information

PRIMERGY SX910 S1 Storage Blade

PRIMERGY SX910 S1 Storage Blade Operating Manual - English PRIMERGY SX910 S1 Storage Blade Operating Manual Edition March 2011 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this

More information

PRIMERGY BX924 S2 Server Blade

PRIMERGY BX924 S2 Server Blade Operating Manual - English PRIMERGY BX924 S2 Server Blade Operating Manual Edition May 2011 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual.

More information

PRIMERGY SX650 Storage Blade. Operating Manual

PRIMERGY SX650 Storage Blade. Operating Manual PRIMERGY SX650 Storage Blade Operating Manual Edition April 2009 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps us

More information

PRIMERGY RX300 S4. Options Guide

PRIMERGY RX300 S4. Options Guide PRIMERGY RX300 S4 Options Guide Edition June 2008 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps us optimize our

More information

FUJITSU Server PRIMERGY RX2510 M2

FUJITSU Server PRIMERGY RX2510 M2 Operating Manual - English FUJITSU Server PRIMERGY RX2510 M2 Operating Manual February 2016 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual.

More information

PRIMERGY RX100 S6 Server. Service Supplement

PRIMERGY RX100 S6 Server. Service Supplement PRIMERGY RX100 S6 Server Service Supplement Edition january 2010 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps us

More information

PRIMERGY RX100 S7 Server

PRIMERGY RX100 S7 Server Operating Manual - English PRIMERGY RX100 S7 Server Operating Manual Edition June 2011 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual.

More information

Chapter 1 Names and Functions This chapter explains the names and functions of the parts.

Chapter 1 Names and Functions This chapter explains the names and functions of the parts. PRIMERGY SX650 Storage Blade Hardware Guide Areas Covered Before Reading This Manual This section explains the notes for your safety and conventions used in this manual. Make sure to read before using

More information

PRIMERGY BX920 S2 Server Blade

PRIMERGY BX920 S2 Server Blade Operating Manual - English PRIMERGY BX920 S2 Server Blade Operating Manual Edition March 2011 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this

More information

PRIMERGY RX300 S2 Server System

PRIMERGY RX300 S2 Server System PRIMERGY PRIMERGY RX300 S2 Server System Monika Spanjaart Fujitsu Siemens Computers GmbH München 81730 Munich e-mail: email: manuals@fujitsu-siemens.com Tel.: (089) 61001160 Fax: (++49) 700 / 372 00000

More information

PRIMERGY RX100 S6 Server. Operating manual

PRIMERGY RX100 S6 Server. Operating manual PRIMERGY RX100 S6 Server Operating manual Edition December 2009 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps us

More information

PRIMERGY TX100 S3 Server

PRIMERGY TX100 S3 Server Operating Manual - English PRIMERGY TX100 S3 Server Operating Manual Edition November 2011 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual.

More information

Operating Manual - English PRIMERGY RX200 S6. Operating Manual

Operating Manual - English PRIMERGY RX200 S6. Operating Manual Operating Manual - English PRIMERGY RX200 S6 Operating Manual April 2010 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback

More information

FUJITSU Server PRIMERGY CX400 M4 Server Enclosure

FUJITSU Server PRIMERGY CX400 M4 Server Enclosure Operating Manual - English FUJITSU Server PRIMERGY CX400 M4 Server Enclosure Operating Manual July 2017 Comments Suggestions Corrections The User Documentation Department would like to know your opinion

More information

FUJITSU Server PRIMERGY TX1330 M2

FUJITSU Server PRIMERGY TX1330 M2 Operating Manual - English FUJITSU Server PRIMERGY TX1330 M2 Operating Manual December 2016 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual.

More information

PRIMERGY TX100 S2 Server

PRIMERGY TX100 S2 Server Operating Manual - English PRIMERGY TX100 S2 Server Operating Manual March 2011 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback

More information

PRIMERGY BX400 S1 Blade Server

PRIMERGY BX400 S1 Blade Server Operating Manual - English PRIMERGY BX400 S1 Blade Server System Unit Operating Manual December 2012 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of

More information

PRIMERGY TX300 S4. Options Guide

PRIMERGY TX300 S4. Options Guide PRIMERGY TX300 S4 Options Guide Edition April 2008 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps us optimize our

More information

PRIMERGY BX900 S2 Blade Server

PRIMERGY BX900 S2 Blade Server Operating Manual - English PRIMERGY BX900 S2 Blade Server System Unit Operating Manual Edition December 2012 Comments Suggestions Corrections The User Documentation Department would like to know your opinion

More information

Serial ATA Hot Swap Drive Cage Upgrade Kit for: Intel Server Chassis SC5200 Intel Server Chassis SC5250-E

Serial ATA Hot Swap Drive Cage Upgrade Kit for: Intel Server Chassis SC5200 Intel Server Chassis SC5250-E Serial ATA Hot Swap Drive Cage Upgrade Kit for: Intel Server Chassis SC5200 Intel Server Chassis SC5250-E A Guide for Technically Qualified Assemblers of Intel Identified Subassemblies/Products Order Number:

More information

PRIMERGY CX122 S1 Server

PRIMERGY CX122 S1 Server Operating Manual - English PRIMERGY CX122 S1 Server Operating Manual Edition November 2010 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual.

More information

FUJITSU Server PRIMERGY TX1320 M3

FUJITSU Server PRIMERGY TX1320 M3 Operating Manual - English FUJITSU Server PRIMERGY TX1320 M3 Operating Manual March 2017 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual.

More information

Obtaining Documentation and Submitting a Service Request, page xvii Safety Warnings, page xvii Safety Guidelines, page xx

Obtaining Documentation and Submitting a Service Request, page xvii Safety Warnings, page xvii Safety Guidelines, page xx Preface Obtaining Documentation and Submitting a Service Request, page xvii Safety s, page xvii Safety Guidelines, page xx Obtaining Documentation and Submitting a Service Request For information on obtaining

More information

Installation Job Aid for Ethernet Routing Switch 3600 Series

Installation Job Aid for Ethernet Routing Switch 3600 Series Installation Job Aid for Ethernet Routing Switch 3600 Series Notices NN47213-303 Issue 03.01 November 2017 Notice paragraphs alert you about issues that require your attention. Following are descriptions

More information

Model 2460-KIT. Screw Terminal Connector Kit. Description / September 2014 *P * 1

Model 2460-KIT. Screw Terminal Connector Kit. Description / September 2014 *P * 1 Keithley Instruments 28775 Aurora Road Cleveland, Ohio 44139 1-800-935-5595 http://www.keithley.com Model 2460-KIT Screw Terminal Connector Kit Description The Model 2460-KIT Screw Terminal Connector Kit

More information

FUJITSU Server PRIMERGY RX100 S8

FUJITSU Server PRIMERGY RX100 S8 Operating Manual - English FUJITSU Server PRIMERGY RX100 S8 Operating Manual Edition May 2014 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this

More information

Fujitsu Cluster-in-a-box based on PRIMERGY BX400-S/M/L PRIMERGY CX420-S/M

Fujitsu Cluster-in-a-box based on PRIMERGY BX400-S/M/L PRIMERGY CX420-S/M User Guide - English Fujitsu Cluster-in-a-box based on PRIMERGY BX400-S/M/L PRIMERGY CX420-S/M Getting Started Edition April 2013 Comments Suggestions Corrections The User Documentation Department would

More information

Operating Manual - English. FUJITSU Server PRIMERGY TX1330 M3 Operating Manual

Operating Manual - English. FUJITSU Server PRIMERGY TX1330 M3 Operating Manual Operating Manual - English FUJITSU Server PRIMERGY TX1330 M3 Operating Manual May2017 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual.

More information

Emerson Network Power provides customers with technical support. Users may contact the nearest Emerson local sales office or service center.

Emerson Network Power provides customers with technical support. Users may contact the nearest Emerson local sales office or service center. Liebert PSA iton User Manual Version: V2.8 Revision date: November 14, 2005 Emerson Network Power provides customers with technical support. Users may contact the nearest Emerson local sales office or

More information

To connect the AC adapter:

To connect the AC adapter: Replacing the AC Adapter Replacing the AC Adapter 3 Plug the power cord into a wall outlet. The power indicator turns on. To connect the AC adapter: Connect the power cord to the AC adapter. Power indicator

More information

PRIMERGY TX120 S3 Server

PRIMERGY TX120 S3 Server Operating Manual - English PRIMERGY TX120 S3 Server Operating Manual Edition May 2012 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual.

More information

UP-1-1 Channel Dimmer dimmer pack. user manual

UP-1-1 Channel Dimmer dimmer pack. user manual UP-1-1 Channel Dimmer dimmer pack user manual Musikhaus Thomann Thomann GmbH Hans-Thomann-Straße 1 96138 Burgebrach Germany Telephone: +49 (0) 9546 9223-0 E-mail: info@thomann.de Internet: www.thomann.de

More information

Installation Job Aid for Ethernet Routing Switch 5900 Series

Installation Job Aid for Ethernet Routing Switch 5900 Series Installation Job Aid for Ethernet Routing Switch 5900 Series Notices NN47211-301 Issue 05.01 November 2017 Notice paragraphs alert you about issues that require your attention. The following paragraphs

More information

PRIMERGY RX200 S7 Server

PRIMERGY RX200 S7 Server Operating Manual - English PRIMERGY RX200 S7 Server Operating Manual Edition November 2013 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual.

More information

UP-1-1 Channel Dimmer. User manual. dimmer pack

UP-1-1 Channel Dimmer. User manual. dimmer pack User manual Musikhaus Thomann Thomann GmbH Hans-Thomann-Straße 1 96138 Burgebrach Germany Telephone: +49 (0) 9546 9223-0 E-mail: info@thomann.de Internet: www.thomann.de 06.11.2017, ID: 152943 Table of

More information

PRIMERGY RX300 S5. Service Supplement

PRIMERGY RX300 S5. Service Supplement PRIMERGY RX300 S5 Service Supplement Edition June 2009 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps us optimize

More information

User Manual AIMB-C200. Economical Embedded Chassis for Mini-ITX Motherboard

User Manual AIMB-C200. Economical Embedded Chassis for Mini-ITX Motherboard User Manual AIMB-C200 Economical Embedded Chassis for Mini-ITX Motherboard Copyright The documentation and the software included with this product are copyrighted 2010 by Advantech Co., Ltd. All rights

More information

B63/ NS MS. EtherNet/IP LINK

B63/ NS MS. EtherNet/IP LINK 3 609 929 B63/ IMenip 2008-09 NS MS EtherNet/IP LINK 3 609 929 B63/2008-09 IMenip Bosch Rexroth AG 15/76 Table of Contents About this document................. 16 General safety instructions............

More information

USER MANUAL. Uninterruptible Power Supply Line-interactive VCL Series UPS VA. GE Critical Power

USER MANUAL. Uninterruptible Power Supply Line-interactive VCL Series UPS VA. GE Critical Power Critical Power USER MANUAL Uninterruptible Power Supply Line-interactive VCL Series UPS 400 600 800 1000 1500 VA GE Consumer & Industrial SA General Electric Company CH 6595 Riazzino (Locarno) Switzerland

More information

D610H, D610H MKII, D610S, D610T dimmer pack. user manual

D610H, D610H MKII, D610S, D610T dimmer pack. user manual D610H, D610H MKII, D610S, D610T dimmer pack user manual Musikhaus Thomann Thomann GmbH Hans-Thomann-Straße 1 96138 Burgebrach Germany Telephone: +49 (0) 9546 9223-0 E-mail: info@thomann.de Internet: www.thomann.de

More information

Table of Contents Quick Install Guide page Introduction Safety Rack System Precautions ESD Precautions...

Table of Contents Quick Install Guide page Introduction Safety Rack System Precautions ESD Precautions... Table of Contents Quick Install Guide page 1 EN English Table of Contents 1. Introduction... 2 1.1 Safety... 2 1.2 Rack System Precautions... 2-3 1.3 ESD Precautions... 3... 3 1... 3 2 Fitting PSU s...

More information

PRIMERGY TX200 S7 Server

PRIMERGY TX200 S7 Server Operating Manual - English PRIMERGY TX200 S7 Server Operating manual Edition June 2012 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual.

More information

DS-2 RF DMX dimmer. user manual

DS-2 RF DMX dimmer. user manual DS-2 RF DMX dimmer user manual Musikhaus Thomann Hans-Thomann-Straße 1 96138 Burgebrach Germany Telephone: +49 (0) 9546 9223-0 E-mail: info@thomann.de Internet: www.thomann.de 11.09.2015, ID: 228802 Table

More information

DPX-620III 6-Ch. dimmer pack. user manual

DPX-620III 6-Ch. dimmer pack. user manual DPX-620III 6-Ch. dimmer pack user manual Musikhaus Thomann Thomann GmbH Hans-Thomann-Straße 1 96138 Burgebrach Germany Telephone: +49 (0) 9546 9223-0 E-mail: info@thomann.de Internet: www.thomann.de 28.08.2017,

More information

Fujitsu Cluster-in-a-box based on PRIMERGY BX400 PRIMERGY CX420 Windows Server 2012 R2 Edition

Fujitsu Cluster-in-a-box based on PRIMERGY BX400 PRIMERGY CX420 Windows Server 2012 R2 Edition User Guide - English Fujitsu Cluster-in-a-box based on PRIMERGY BX400 PRIMERGY CX420 Windows Server 2012 R2 Edition Getting Started Edition May 2014 Comments Suggestions Corrections The User Documentation

More information

FUJITSU Server PRIMERGY RX2510 M2

FUJITSU Server PRIMERGY RX2510 M2 Operating Manual - English FUJITSU Server PRIMERGY RX2510 M2 Operating Manual June 2017 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual.

More information

PRIMERGY TX300 S3 Server

PRIMERGY TX300 S3 Server PRIMERGY PRIMERGY TX300 S3 Server Options Guide Susanne Däschlein Fujitsu Siemens Computers GmbH München 81730 München e-mail: email: manuals@fujitsu-siemens.com Tel.: (089) 61001155 Fax: (++49) 700 /

More information

FUJITSU Server PRIMERGY TX2540 M1

FUJITSU Server PRIMERGY TX2540 M1 Operating Manual - English FUJITSU Server PRIMERGY TX2540 M1 Operating Manual January 2017 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual.

More information

PRIMERGY TX300 S4 Server. Options Guide

PRIMERGY TX300 S4 Server. Options Guide PRIMERGY TX300 S4 Server Options Guide Edition December 2007 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps us optimize

More information

Chapter 1 Component Names and Functions This chapter explains the component names and functions of the server.

Chapter 1 Component Names and Functions This chapter explains the component names and functions of the server. PRIMERGY BX600 S2 Blade Server System Unit Hardware Guide Areas Covered Before Reading This Manual This section explains the notes for your safety and conventions used in this manual. Make sure to read

More information

PRIMERGY TX150 S5 Server

PRIMERGY TX150 S5 Server PRIMERGY PRIMERGY TX150 S5 Server Options Guide Däschlein Fujitsu Siemens Computers GmbH München 81730 München e-mail: email: manuals@fujitsu-siemens.com Tel.: (089) 61001155 Fax: 0 700 / 372 00000 TX150

More information

Upgrading and Servicing Guide

Upgrading and Servicing Guide Upgrading and Servicing Guide Copyright Information The only warranties for Hewlett-Packard products and services are set forth in the express statements accompanying such products and services. Nothing

More information

FUJITSU Server PRIMERGY RX1330 M3

FUJITSU Server PRIMERGY RX1330 M3 Operating Manual - English FUJITSU Server PRIMERGY RX1330 M3 Operating Manual March 2017 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual.

More information

DMX Splitter 4 MKIII 19" DMX splitter. user manual

DMX Splitter 4 MKIII 19 DMX splitter. user manual DMX Splitter 4 MKIII 19" DMX splitter user manual Musikhaus Thomann Thomann GmbH Hans-Thomann-Straße 1 96138 Burgebrach Germany Telephone: +49 (0) 9546 9223-0 E-mail: info@thomann.de Internet: www.thomann.de

More information

DS-1H05 Ethernet-over-Coax Extender. User Manual

DS-1H05 Ethernet-over-Coax Extender. User Manual DS-1H05 Ethernet-over-Coax Extender User Manual Thank you for purchasing our product. If there is any question or request, please do not hesitate to contact dealer. This manual is applicable to DS-1H05-T,

More information

FUJITSU Server PRIMERGY RX2520 M1

FUJITSU Server PRIMERGY RX2520 M1 Operating Manual - English FUJITSU Server PRIMERGY RX2520 M1 Operating manual Edition February 2015 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of

More information

MC 11 EB-2 Power supply cabinet with external bus, AC version

MC 11 EB-2 Power supply cabinet with external bus, AC version MC 11 EB-2 Power supply cabinet with external bus, AC version USER/MAINTENANCE MANUAL 1 SLOT 0 SLOT 1 SLOT 2 SLOT 3 SLOT 4 SLOT 5 SLOT 6 SLOT 7 SLOT 8 SLOT 9 SLOT 10 SLOT 11 EB-2 (a) MC11 (b) (c) Figures

More information

SATA II HDD Canister KISS DA 435 Quick Reference Guide

SATA II HDD Canister KISS DA 435 Quick Reference Guide SATA II HDD Canister KISS DA 435 Quick Reference Guide If it s embedded, it s Kontron 1. Table of Contents SATA II HDD Canister KISS DA 435 1. Table of Contents 1. Table of Contents... 1 2. Important Information...

More information

Installation Job Aid for VSP 4450GTX-HT- PWR+

Installation Job Aid for VSP 4450GTX-HT- PWR+ Installation Job Aid for VSP 4450GTX-HT- PWR+ Notices Release 6.1.0.0 NN46251-305 Issue 02.01 November 2017 Notice paragraphs alert you about issues that require your attention. The following paragraphs

More information

The power behind competitiveness. Delta Infrasuite Power Management. Power Distribution Unit. User Manual.

The power behind competitiveness. Delta Infrasuite Power Management. Power Distribution Unit. User Manual. The power behind competitiveness Delta Infrasuite Power Management Power Distribution Unit User Manual www.deltapowersolutions.com Save This Manual This manual contains important instructions and warnings

More information

3-4 SAS/SATA II HDD Canister Entry version USER S MANUAL XC-34D1-SA10-0-R. Document number: MAN A

3-4 SAS/SATA II HDD Canister Entry version USER S MANUAL XC-34D1-SA10-0-R. Document number: MAN A 3-4 SAS/SATA II HDD Canister Entry version XC-34D1-SA10-0-R USER S MANUAL Document number: MAN-00077-A ii Preface Important Information Warranty Our product is warranted against defects in materials and

More information

User Guide - English. FUJITSU Software ServerView Suite. Local Service Panels. Local Service Concept (LSC)

User Guide - English. FUJITSU Software ServerView Suite. Local Service Panels. Local Service Concept (LSC) User Guide - English FUJITSU Software ServerView Suite Local Service Panels Local Service Concept (LSC) Last Edition August 2017 Comments Suggestions Corrections The User Documentation Department would

More information

JanusRAID SA-6692J Hardware User Manual

JanusRAID SA-6692J Hardware User Manual JanusRAID SA-6692J Hardware User Manual 42-30000-5067 SATA II JBOD enclosure Version 1.1 SA-6692J SATA II JBOD enclosure Hardware User Manual Table of Contents Preface... i Chapter 1 System Requirements

More information

Installation Job Aid for VSP 4850GTS

Installation Job Aid for VSP 4850GTS Installation Job Aid for VSP 4850GTS Notices Release 6.1.0.0 NN46251-308 Issue 02.01 November 2017 Notice paragraphs alert you about issues that require your attention. The following paragraphs describe

More information

CM E FUJITSU SEMICONDUCTOR CONTROLLER MANUAL F 2 MC-16L/16LX EMULATION POD MB HARDWARE MANUAL

CM E FUJITSU SEMICONDUCTOR CONTROLLER MANUAL F 2 MC-16L/16LX EMULATION POD MB HARDWARE MANUAL FUJITSU SEMICONDUCTOR CONTROLLER MANUAL CM42-00411-2E F 2 MC-16L/16LX EMULATION POD MB2145-507 HARDWARE MANUAL F 2 MC-16L/16LX EMULATION POD MB2145-507 HARDWARE MANUAL FUJITSU LIMITED PREFACE Using the

More information

Chapter 1 Component Names and Functions This chapter explains the component names and functions of the server.

Chapter 1 Component Names and Functions This chapter explains the component names and functions of the server. PRIMERGY BX600 S2 Blade Server System Unit Hardware Guide Areas Covered Before Reading This Manual This section explains the notes for your safety and conventions used in this manual. Make sure to read

More information

icore Kiosk system Installation Guide

icore Kiosk system Installation Guide icore Kiosk system Installation Guide The reproduction, transmission or use of this document or its contents is not permitted without express authority. Offenders will be liable for damages. All rights,

More information

FUJITSU Server PRIMERGY RX2530 M4

FUJITSU Server PRIMERGY RX2530 M4 Operating Manual - English FUJITSU Server PRIMERGY RX2530 M4 Operating Manual July 2017 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual.

More information

650/1000 Fresnel 650/1000 PC 300/500 Antihalo 300/500 Fresnel theatre spotlight. user manual

650/1000 Fresnel 650/1000 PC 300/500 Antihalo 300/500 Fresnel theatre spotlight. user manual 650/1000 Fresnel 650/1000 PC 300/500 Antihalo 300/500 Fresnel theatre spotlight user manual Musikhaus Thomann Thomann GmbH Hans-Thomann-Straße 1 96138 Burgebrach Germany Telephone: +49 (0) 9546 9223-0

More information

PRIMERGY BX920 S1 Server-Blade. Service Supplement

PRIMERGY BX920 S1 Server-Blade. Service Supplement PRIMERGY BX920 S1 Server-Blade Service Supplement Edition April 2010 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps

More information

D1210H dimmer pack. user manual

D1210H dimmer pack. user manual D1210H dimmer pack user manual Musikhaus Thomann Thomann GmbH Hans-Thomann-Straße 1 96138 Burgebrach Germany Telephone: +49 (0) 9546 9223-0 E-mail: info@thomann.de Internet: www.thomann.de 13.08.2015,

More information

Read Me First. FUJITSU Storage ETERNUS CS800 S6. Table of Contents P3AM EN. ETERNUS CS800 S6 Manuals Package Contents...

Read Me First. FUJITSU Storage ETERNUS CS800 S6. Table of Contents P3AM EN. ETERNUS CS800 S6 Manuals Package Contents... FUJITSU Storage ETERNUS CS800 S6 Read Me First Fujitsu would like to thank you for purchasing our FUJITSU Storage ETERNUS CS800 S6 (hereinafter referred to as "ETERNUS CS800 S6"). Read this document and

More information

LED Pixel Rail Drive 640 controller. user manual

LED Pixel Rail Drive 640 controller. user manual LED Pixel Rail Drive 640 controller user manual Musikhaus Thomann Thomann GmbH Hans-Thomann-Straße 1 96138 Burgebrach Germany Telephone: +49 (0) 9546 9223-0 E-mail: info@thomann.de Internet: www.thomann.de

More information

Installation Manual. Mounting Instructions Mechanical Mounting. Luminato. Teleste Corporation

Installation Manual. Mounting Instructions Mechanical Mounting. Luminato. Teleste Corporation Luminato Installation Manual Teleste Corporation Mounting Instructions Mechanical Mounting Luminato Mechanical Installation, agile_59300316, rev0044 Introduction 1 Contents Introduction 4 General... 4

More information

Multi-Mount for Mac Pro " to 5.25" Drive Bay Converter Bracket. Assembly & Installation Manual

Multi-Mount for Mac Pro  to 5.25 Drive Bay Converter Bracket. Assembly & Installation Manual Multi-Mount for Mac Pro 2009-2010 3.5" to 5.25" Drive Bay Converter Bracket Assembly & Installation Manual Introduction 1 INTRODUCTION 1.1 System Requirements 1.1.1 Computer Requirements 1.1.2 Hard Drive

More information

Installation of the POTS splitter card requires the following steps: Determining the cables you need. Installing the POTS splitter chassis

Installation of the POTS splitter card requires the following steps: Determining the cables you need. Installing the POTS splitter chassis 5910 High Density Lifeline POTS Splitter Installation Instructions Document Number 5910-A2-GZ40-00 May 2005 About the 5910 POTS Splitter The 5910 is a double-density POTS splitter that separates the (Digital

More information