AS-Interface Bus Control System
|
|
- Tabitha Chambers
- 5 years ago
- Views:
Transcription
1 AS-Interface Bus Control System Versatile system easily expandable Dedicated modules linked to Nugget Valve Islands Overall Fieldbus control achieved via gateway Complete range of accessories EMC compliant (Directive 89/6/EEC) Technical Data Protocol: AS-Interface: inputs/outputs per module (Special inputs/outputs modules also available) Bus Topology: Tree, Star, Ring or Line with spurs System configuration: Single master, multi-slaves Communication: AS-Interface Max baud rate: 5ms cycle time with slaves Cable length at max baud rate: 00m +00m per repeater Number of units per AS-I network: Master + slaves (6 slaves with double master controller) Addressing: Set on controller or by hand held unit Cable: AS-I Line Yellow Power Black Voltage: Power: V d.c. Communication (AS-I line): 9.6V d.c. Operating Temperature: -5 to +80 C (modules) Ordering Information Consult tables on following pages. To order AS-Interface Valve Islands refer to the Nugget 0 Valve Island data sheet (5..) and Nugget 0 Valve Island data sheet (5..56). For your local Norgren Technical Sales Centre phone For your local Norgren Distributor phone IMI Norgren Limited, PO Box, Eastern Avenue, Lichfield, Staffordshire WS 6SB N/UK
2 Essen Essen ALARM CONFIG NOT AUTO ADDR PW COM MOD PROJ MOD CTR P ALAR M NOT AUTO ADDR PW COM MOD PROJ MOD CTR 0 V + V P 0 V + V Essen ADDR PW COM MOD PROJ MOD CTR ALARM 0 V P Essen 0 V P ALAR M ADDR PW COM MOD PROJ MOD CTR AS-Interface Bus System NOT AUTO MOD SE -DP-CONTROLLER Bestell-Nr.: AC 00 ifm electronic gmbh D 57 + V 6.. CONFIG NOT AUTO SE -DP-CONTROLLER Bestell-Nr.: AC 008 ifm electronic gmbh D 57 + V 5 KEY Input device (eg reed switch) Junction box Solenoid coil plug Tee connector Power Cable (V d.c.) Cable (9,6V d.c.). Valve island with inputs/ outputs. Valve island with 8 outputs. Valve island with inputs/ outputs. Valve island with outputs. output module. input and output module. input and output module. input module Power Supply, V dc AS-I Supply, 9.6V dc 5 Gateway/Controller 6 Master Controller Group Item Description Part Number Detail Page Number Valve Islands with integral AS-I Modules Please refer to data sheets 5.. (Nugget 0 Valve Islands) and (Nugget 0 Valve Islands) Input/Output Modules. Output module VEAS Input + Output module VEAS Input + Output module VEAS Input module VEAS Power Supply for V d.c.. 5/0V a.c. V d.c.,5a VEASPS /0V a.c. V d.c. 5A VEASPS /0V a.c. V d.c. 0A VEASPS SE -DP-CONTROLLER Bestell-Nr.: AC 008 ifm electronic gmbh D 57 MOD SE -DP-CONTROLLER Bestell-Nr.: AC 00 ifm electronic gmbh D 57 AS-I Supply for 9.6V d.c. (communication). 5/0V a.c. 9.6V d.c. 85W VEASPS V d.c. 9.6V d.c. 85W VEASPS /0V a.c. 9.6V d.c. 80W VEASPS /0V a.c. 9.6V d.c. + V d.c. 80W (combined) VEASPS Gateway/Controller 5. Profibus DP Master card ( slaves) VAASCT-DP Profibus DP Master cards (6 slaves) VAASCT-DP Devicenet Master card ( slaves) VAASCT-DNT Interbus S Master card ( slaves) VEASCT-IBS Master Controller 6. Master card ( slaves) VEASCT-RS Master cards (6 slaves) VEASCT-RS N/** For your local Norgren Technical Sales Centre phone For your local Norgren Distributor phone IMI Norgren Limited, PO Box, Eastern Avenue, Lichfield, Staffordshire WS 6SB
3 Accessories Symbol Description Connection size Straight/Elbow Cable Length Part Number Page (metres) Number Output M plug and cable assemblies for solenoid coils Wireable 5 pin male plug screw termination M Straight - VEFBCRS-M5P Connecting cable 5 pin plug to valve connection Type C (5mm coil) M Straight - VEFBCSC-M Connecting cable 5 pin plug to valve connection Type C (5mm coil) M Straight 0, VEFBCSC-M Connecting cable 5 pin plug to valve connection Industrial (mm coil) M Straight,0 VEFBCSB-M Connecting cable 5 pin plug to valve connection Industrial (mm coil) M Straight 0, VEFBCSB-M Connecting cable 5 pin plug to valve connection Type A (mm coil) M Straight,0 VEFBCSA-M Connecting cable 5 pin plug to valve connection Type A (mm coil) M Straight 0, VEFBCSA-M Input/sensor and drop line plug and cable assemblies Wireable 5 pin male input sensor plug screw termination M Straight - VEFBCRS-M5P Connecting cable pin plug to pin socket M/Ø8 Straight/Straight VEFBC8S-M Connecting cable pin plug to pin socket M/Ø8 Straight/Straight VEFBC8S-M Connecting cable pin plug to pin socket M/Ø8 Straight/Straight 5 VEFBC8S-M Connecting cable pin plug to pin socket M/Ø8 Straight/Elbow VEFBC8E-M Connecting cable pin plug to pin socket M/Ø8 Straight/Elbow VEFBC8E-M Connecting cable pin plug to pin socket M/Ø8 Straight/Elbow 5 VEFBC8E-M Connecting cable pin plug to pin socket (for drop line too) M/M Straight/Straight VEFBC0S-M Connecting cable pin plug to pin socket (for drop line too) M/M Straight/Straight VEFBC0S-M Connecting cable pin plug to pin socket (for drop line too) M/M Straight/Straight 5 VEFBC0S-M Tee Connector Tee connector for communication or power cable to M female M VEASCN-M Blanking Plugs Blanking plug for unused M connectors M VEFBCBK-M Installation cables for AS-Interface systems YM5 flat yellow cable (thermoplastic elastomer) 5, 50, 00m VEASCAY-YMXXX YM5 flat black cable (thermoplastic elastomer) 5, 50, 00m VEASCAB-YMXXX Clip for cable Cable clip for cable (quantity 00) VEASAC-CL Programming cable To connect RS-C coupler from AS-I Controller with PC socket to socket sub D9 pin VEASPRG-PCETL Junction Box For cable junctions - VEASCN-JB Hand held addressing unit For addressing connected modules, intelligent sensors and actuators VEASHP Software and Handbook Software and Handbook English VEASMA-E Software and Handbook German VEASMA-G N/** For your local Norgren Technical Sales Centre phone For your local Norgren Distributor phone IMI Norgren Limited, PO Box, Eastern Avenue, Lichfield, Staffordshire WS 6SB
4 Group Input/Output Modules. VEAS Input Module. VEAS Input and Output Module. VEAS Output Module PE Flat cable yellow PE ground Flat cable black M x,5 07. VEAS Input and Output Module 5 0 I- O- I- O- I- O- 6 I- O- I- O- I- O- I- O I- O- Flat cable yellow PE ground Flat cable black M x 07,5 Pin input connection Pin output connection Module/Socket Pin Sensor supply + Sensor supply - + Signal input 5 Module/Socket Pin Switch output + External voltage - 5 Potential earth Mechanical switch Reed switch + Signal -wire -solenoid- idle run diode recommended + - -wire -pnp-sensor + - Signal -wire-pnp-sensor L+ A N/UK For your local Norgren Technical Sales Centre phone For your local Norgren Distributor phone IMI Norgren Limited, PO Box, Eastern Avenue, Lichfield, Staffordshire WS 6SB
5 Group Input/Output Modules Technical Specification Description. ( Inputs). ( Inputs and Outputs). ( Outputs). ( Inputs and Outputs) VEAS VEAS VEAS VEAS Operating voltage according 6,5 to,6v d.c. 6,5 to,6v d.c. 6,5 to,6v d.c. 6,5 to,6v d.c. to AS-I specification Total current consumption 0mA 0mA 75mA 5mA Input circuit PNP PNP - PNP Inputs: Sensor supply - Voltage range 0 to 0V d.c. 0 to 0V d.c. - 0 to 0V d.c. Maximum current load 00mA 00mA - 00mA for all inputs total Short circuit protected - Switch level high signal 0V 0V - 0V Input current (high/low) 5 /,5mA 5 /,5mA - 5 /,5mA Outputs: Galvanically isolated - Short circuit protected - Watchdog - Maximum current load - A A A per o/p Voltage supply - V d.c. nominal V d.c. nominal V d.c. nominal Reverse polarity protection AS-I profile S 0,0 S,0 S 8,0 S 7,0 I/O configuration (Hex) ID code (Hex) AS-I certificate EMC Noise emmission EN EN EN EN Noise immunity EN EN EN EN Protection class IP 67 IP 67 IP 67 IP 67 Temperature range -5 C to+80 C -5 C to+80 C -5 C to+80 C -5 C to+80 C Number of sockets 8 Input/output signal Yellow Yellow Yellow Yellow indicators AS-I Voltage indicator Green Green Green Green AS-I Housing material Polyurethane Polyurethane Polyurethane Polyurethane Allocation of data bits D0 I- I- 0- I- / 0- D I- I- 0- I- / 0- D I I- / 0- D I I- / 0- Connection Caution Via contact pins in the device base remove cover for access The acceptable current load of the outputs amounts to max of,0a per module Inputs and outputs must be isolated N/UK For your local Norgren Technical Sales Centre phone For your local Norgren Distributor phone IMI Norgren Limited, PO Box, Eastern Avenue, Lichfield, Staffordshire WS 6SB
6 Group V d.c. Power Supplies for outputs (black cable). VEASPS-0609,5A 0 0 7,5 7,5 0. VEASPS-09 5A 7 0 7,5 7,5 0. VEASPS-09 0A ,5 7,5 00 N/UK For your local Norgren Technical Sales Centre phone For your local Norgren Distributor phone IMI Norgren Limited, PO Box, Eastern Avenue, Lichfield, Staffordshire WS 6SB
7 V d.c. Power Supplies Technical Specification Description... VEASPS-0609,5A VEASPS-09 5A VEASPS-09 0A Output current,5a 5A 0A Nominal voltage 5/0V selectable 5/0V selectable 5/0V selectable Input voltage range 88-/87-6Va.c. 88-/87-6Va.c. 88-/87-6Va.c. Nominal frequency 7-6Hz 7-6Hz 7-6Hz Efficiency 87% 88% 88% Housing Aluminium Aluminium Aluminium Protection class IP0 IP0 IP0 Connection,5mm clamps,5mm clamps,5mm clamps Temperature range 0 C to +60 C 0 C to +60 C 0 C to +60 C Derating 60 C to 70 C 60 C to 70 C 60 C to 70 C Output voltage V d.c. ± % V d.c. ± % V d.c. ± % High run-time ms 0ms 5ms Residual ripple % % % Bridgeable power failure time 6ms 7ms 5ms Peak starting current A 6A 50A Overload proof Over voltage protection EMC Interference suppression VDE 087/B EN 550/B VDE 087/B EN 550/B VDE 087/B EN 550/B Protection class Extra low voltage protection SELV SELV SELV Integrated protection TA/50V T5A/50V T5A/50V Weight 60g 60g 00g Indicators Green for output voltage Green for output voltage Green for output voltage Power failure - - Output high at 8>60V Terminal allocation Secondary V dc 0V dc Secondary V dc 0V dc PF Primary N Supply L Primary N Supply L N/UK For your local Norgren Technical Sales Centre phone For your local Norgren Distributor phone IMI Norgren Limited, PO Box, Eastern Avenue, Lichfield, Staffordshire WS 6SB
8 Group AS-I 9.6V d.c. Power Supplies for AS-I Communication and Inputs (yellow cable). VEASPS W AS-I supply a.c.. VEASPS W AS-I supply d.c ,5 7,5 0. VEASPS W AS-I supply a.c ,5 7,5 0. VEASPS W Combined AS-I 9.6V d.c. and V d.c. Power Supply ,5 7,5 00 N/UK For your local Norgren Technical Sales Centre phone For your local Norgren Distributor phone IMI Norgren Limited, PO Box, Eastern Avenue, Lichfield, Staffordshire WS 6SB
9 AS-I 9.6V d.c. Power Supplies for AS-I Communication and Inputs (yellow cable) Technical Specification Description.... VEASPS W a.c. VEASPS W d.c. VEASPS W a.c. VEASPS W combined AS-I (9.6V ) & output power (V) Output current,8a,8a 8A,8/6A Nominal voltage 5/0Va.c. selectable Vd.c. 5/0V selectable 5/0V selectable Input voltage range 88-/87-6Va.c.,6-6,Vd.c.. 88-/87-6Va.c. 88-/87-6Va.c. Nominal frequency 7-6Hz - 7-6Hz 7-6Hz Efficiency 87% 87% 88% 88% Housing Aluminium Aluminium Aluminium Aluminium Protection class IP0 IP0 IP0 IP0 Connection,5mm clamps,5mm clamps,5mm clamps,5mm clamps Temperature range 0 to +60 C 0 C to +60 C 0 C to +60 C -0 C to +60 C Derating 60 C to 70 C 60 C to 70 C 60 C to 70 C 60 C to 70 C Output voltage 9,5 to,6d.c. 9,5 to,6vd.c. 9,5 to,6vd.c. 9,5 to,6vd.c./v d.c. ±% High run-time ms ms 0ms - Residual ripple % % % % Bridgeable power failure time 6ms 7ms 5ms - Peak starting current A 6A 50A - Overload proof Over voltage protection EMC Interference suppression VDE 087/B; EN 550/B VDE 087/B; EN 550/B VDE 087/B; EN 550/B VDE 087/B; EN 550/B Protection class Extra low voltage protection PELV PELV PELV PELV Integrated protection TA/50V - T5A/50V - Weight 60g 60g 00g - Approvals TBA TBA TBA TBA Indicators Green for output voltage Green for output voltage Green for output voltage Green for output voltage Terminal allocation N.C. Secondary Primary asi asi Screen L N Supply Secondary Primary asi asi Screen Supply Secondary Primary asi asi Screen L N Supply Primary L N V dc V dc Shield AS-I AS-I N/UK For your local Norgren Technical Sales Centre phone For your local Norgren Distributor phone IMI Norgren Limited, PO Box, Eastern Avenue, Lichfield, Staffordshire WS 6SB
10 Group 5 Gateway/Controller For standalone AS-I Control and Gateway connection to other protocols 5. VAASCT-DP000 AS-I/ProfiBus-DP Gateway Controller ( master, slaves) 5. VAASCT-DP000 AS-I/ProfiBus-DP Gateway Controller ( masters, 6 slaves) 50 ALARM CONFIG NOT AUTO ADDR PWR COM PROJ CTRL -DP-CONTROLLER Bestell-Nr.: AC 006 ifm electronic gmbh D 57 Essen Made in Germany + + V 0 V + PE SET 0 7,5 7, VAASCT-DNT00 AS-I DeviceNet Gateway Controller ( master, slaves) 50 ALARM CONFIG NOT AUTO ADDR PWR COM PROJ CTRL -DP-CONTROLLER Bestell-Nr.: AC 008 ifm electronic gmbh D 57 Essen Made in Germany + V 0 V + PE SET 0 7,5 7,5 0 See page for information on AS-I configuration and controller programming software. N/UK For your local Norgren Technical Sales Centre phone For your local Norgren Distributor phone IMI Norgren Limited, PO Box, Eastern Avenue, Lichfield, Staffordshire WS 6SB
11 Gateway/Controllers Technical Specification Description VAASCT-DP000 VAASCT-DP000 VAASCT-DNT00 ProfiBus-DP ( master) ProfiBus-DP ( master) DeviceNet ( master) Operating voltage 5-0V d.c. (typ V d.c.) 5-0V d.c. (typ V d.c.) 5-0V d.c. (typ V d.c.) Power consumption 0W 0W 0W Serial interfaces RS C RS C RS C Transm. rate Transm. rate Transm. rate 800/600 baud 800/600 baud 800/600 baud AS-I Interfaces Specification to AS-I Specification to AS-I Specification to AS-I Fieldbus Interface ProfiBus-DP to DIN 95 Part ProfiBus-DP todin 95 Part DeviceNet No. of screw clamps Function indicator x red, x green, x yellow x red, x green, x yellow x red, x green, x yellow Control buttons x x x x SET/-digit x SET/-digit x SET/-digit Ambient temperature 0 C to +70 C 0 C to +70 C 0 C to +70 C Housing Clamp rail housing Clamp rail housing Clamp rail housing can mount on DIN rails can mount on DIN rails can mount on DIN rails Protection class Housing: IP0 Housing: IP0 Housing: IP0 Terminals: IP0 Terminals: IP0 Terminals: IP0 Functions on Control panel Red Configuration alarm Red Auto addressing blocked Green AS-I power Green Normal operation Yellow Configuration mode Yellow (flashing) Unprotected mode Yellow Controller in RUN mode ALARM CONFIG NOT AUTO ADDR PWR COM PROJ CTRL SET Block diagram Connection schematic Clamps 6 and 7 apply only to. VAASCT-DP V 0V + - PE cable wire operation voltage cable wire Ground 5 +V 0V + - PE operation voltage network Ground N/UK For your local Norgren Technical Sales Centre phone For your local Norgren Distributor phone IMI Norgren Limited, PO Box, Eastern Avenue, Lichfield, Staffordshire WS 6SB
12 Group 5 AS-I InterBus-S Gateway Controller 5. VEASCT-IBS00 AS-I InterBus-S Gateway Controller ( master, slaves) UL CC BA TR CONFIG ERR U ACTIVE SET 5 56 PRG ENABLE PRJ See page for information on AS-I configuration on AS-I configuration and controller programming software. N/UK For your local Norgren Technical Sales Centre phone For your local Norgren Distributor phone IMI Norgren Limited, PO Box, Eastern Avenue, Lichfield, Staffordshire WS 6SB
13 AS-I InterBus-S Gateway Controller Technical Specification Description VEASCT-IBS00 Operating voltage Current consumption AS-I Interfaces Supply via external power supply 9V d.c. internal supply via bus terminal Typ. 0 ma No. of slaves (max) + slave 0 No. of digital inputs/outputs Standard operation Bidirectional operation inputs and outputs Operating states Evaluation via program display -digit LCD display Master function to specification Data calls Parameter calls Address calls Protection class Operating temperature Note IP0 0 C to +60 C Access to peripheral equipment in the same way as to InterBus-S peripheral equipment. Existing programs can be used. The -InterBus gateway allows coupling to a variety of control systems: AEG-Modicon, Bosch, Siemens, Allen-Bradley Functions on Control panel Green Remote Bus Green IBS int supply, one module Green ST Cable check Green PCP Communication Red Preset/actual Config different Green supply Green Normal operation data exch Green Programming mode Yellow Planning mode UL BA CC TR CONFIG ERR U ACTIVE PRG ENABLE PRJ SET Connections Terminals,5, and not used N/UK For your local Norgren Technical Sales Centre phone For your local Norgren Distributor phone IMI Norgren Limited, PO Box, Eastern Avenue, Lichfield, Staffordshire WS 6SB
14 Group 6 AS-I Master Controller 6. VEASCT-RS Controller, master ( slaves) 6. VEASCT-RS Controller, masters(6 slaves) 50 ALARM CONFIG NOT AUTO ADDR PWR COM PROJ CTRL -DP-CONTROLLER Bestell-Nr.: AC 00 ifm electronic gmbh D 57 Essen Made in Germany + + V 0 V + PE SET 0 7,5 7,5 0 See page for information on AS-I configuration and controller programming software. N/UK For your local Norgren Technical Sales Centre phone For your local Norgren Distributor phone IMI Norgren Limited, PO Box, Eastern Avenue, Lichfield, Staffordshire WS 6SB
15 AS-I Master Controllers Technical Specification Description VEASCT-RS VEASCT-RS Controller ( master) Controller ( masters) Operating voltage 0-0V d.c. (typ V d.c.) 0-0V d.c. (typ V d.c.) Power consumption 0W 0W Serial interfaces RS C RS C Transm. rate 9600/900 baud Transm. rate 9600/900 baud AS-I Interfaces To AS-I specification To AS-I specification No. of screw clamps 5 7 Function indicator x red, green and yellow x red, green and yellow Control buttons x x x SET/-digit x SET/-digit Ambient temperature 0 C to +70 C 0 C to +70 C Housing Clamp rail housing Clamp rail housing can mount on DIN rails can mount on DIN rails Protection class Housing: IP0 Housing: IP0 Clamps: IP0 Clamps: IP0 Functions on Control panel Red Configuration alarm Red Auto addressing blocked Green AS-I power Green Normal operation Yellow Configuration Yellow (flashing) Unprotected mode Yellow Controller in RUN mode ALARM CONFIG NOT AUTO ADDR PWR COM PROJ CTRL SET Block diagram Connection schematic Clamps 6 and 7 apply only to 6. VEASCT-RS V 0V + - PE network wire operating voltage network wire Ground N/UK For your local Norgren Technical Sales Centre phone For your local Norgren Distributor phone IMI Norgren Limited, PO Box, Eastern Avenue, Lichfield, Staffordshire WS 6SB
16 Software and Handbook VEASMA-E0000 VEASMA-G0000 English German The Ecolog AS-I system software enables complete operation of AS-I systems. AS-I software used for Configuration of interface Programming controller Diagnosis/visualation of data in controller Hardware required IBM personal computer or compatible. Min 86 Microsoft Windows. or higher RAM memory min MB Programming language Connection IEC-- From PC and AS-I Controller via normal serial interface (RS C) Configuration Straight forward configuration of your AS-I network using this menu driven software. Programming The powerful Ecolog software offers a wide range of features for programming of simple to highly sophisticated applications. You can choose your favourite programming language from popular options including: Ladder Diagram Function Block Diagram Instruction List Sequential Function Chart A wide variety of functions are available including: Logical AND, OR, NOT. Set/Restet, flip-flop etc. Comparison GREATER/LESS THAN, EQUAL TO etc. Mathematical ADD, MULTIPLY, DIVIDE etc. Other Features Timers and Counters, Data Type Conversion, Bit Shifts, Arrays and Numerical Functions (SIN, COS, SQRT etc.) The Ecolog software also offers on-screen process visulation and program simulation. N/UK For your local Norgren Technical Sales Centre phone For your local Norgren Distributor phone IMI Norgren Limited, PO Box, Eastern Avenue, Lichfield, Staffordshire WS 6SB
17 Accessories AS-Interface Bus Control Wireable plug for input or output cable assemblies VEFBCRS-M5P Wireable 5 pin male plug screw termination 55 5 PG7 gland Ø0 Face mm Male connector male thread Output M plug and cable assemblies for solenoid coils VEFBCSC-M0 0.m Connecting cable 5 pin plug to valve connection DIN 650 Form C (5mm) VEFBCSC-M0 m Connecting cable 5 pin plug to valve connection DIN 650 Form C (5mm) VEFBCSB-M0 0,m Connecting cable 5 pin plug to valve connection Industrial (mm coil) VEFBCSB-M0 m Connecting cable 5 pin plug to valve connection Industrial (mm coil),5 'L' 0,5 'L' Pin Mx Male connector male thread Form 'C' solenoid connector Pin Mx Male connector male thread Industrial solenoid connector VEFBCSA-M0 0,m Connecting cable 5 pin plug to valve connection DIN 650 Form A (0mm coil) VEFBCSA-M0 m Connecting cable 5 pin plug to valve connection DIN 650 Form A (0mm coil),5 'L' Pin Mx Male connector male thread 8 Form 'A' solenoid connector N/UK For your local Norgren Technical Sales Centre phone For your local Norgren Distributor phone IMI Norgren Limited, PO Box, Eastern Avenue, Lichfield, Staffordshire WS 6SB
18 AS-Interface Bus Control System Accessories Input /sensor and drop line plug and cable assemblies Cables with straight sensor connection VEFBC8S-M0 m Connecting cable pin plug M to pin socket (Ø8) VEFBC8S-M0 m Connecting cable pin plug M to pin socket (Ø8) VEFBC8S-M50 5m Connecting cable pin plug M to pin socket (Ø8) Cables with right angled sensor connection VEFBC8E-M0 m Connecting cable pin plug M to pin socket (Ø8) VEFBC8E-M0 m Connecting cable pin plug M to pin socket (Ø8) VEFBC8E-M50 5m Connecting cable pin plug M to pin socket (Ø8),5 'L' 0,5 9,5 'L' 0 6 Pin Mx Male connector male thread Ø8 Female connector Socket Pin Mx Male connector male thread Ø8 Female right angled connector Socket VEFBC0S-M0 Connecting cable pin plug M to pin socket M* VEFBC0S-M0 Connecting cable pin plug M to pin socket M* VEFBC0S-M50 Connecting cable pin plug M to pin socket M*, 'L' 5, Pin Mx Male connector male thread *Can also be used for drop line connections Ø,7 Ø,7 Mx Female connector Socket Tee connector VEASCN-M00 Tee connector for communication or power cable to M female Blanking plugs VEFBCBK-M00 Blanking plug for unused M connectors,7 0, 5 Mx 0 0 N/UK For your local Norgren Technical Sales Centre phone For your local Norgren Distributor phone IMI Norgren Limited, PO Box, Eastern Avenue, Lichfield, Staffordshire WS 6SB
19 Accessories AS-Interface Bus Control System Installation cables for AS-Interface systems VEASCAY-YMXXX YM5 flat yellow cable* VEASCAB-YMXXX YM5 flat yellow cable* XXX = cable length in metres: 05, 075, 00 * thermoplastic elastomer for oil resistance Junction box VEASCN-JB ,5 0 0,5 0 7,6 Blue 6,5 Brown Cable clip for AS-I cable Part Number (pack of 00) cable VEASAC-CL00 Programming cable m VEASPRG-PCETL To connect RS- C coupler from AS-I Controller with PC Socket to socket sub-d 9 pin 9 way female D-type connector 9 way female D-type connector Hand held AS-I addressing unit VEASHP For addressing connected modules, intelligent sensors and actuators Technical Specification 80 0 Battery operated 09 Keyboard Increment slave address Decrement slave address write Address slave read Read slave/unit ON Socket Warning These products are intended for use in industrial control systems only. Do not use these products where voltage, current and temperatures can exceed those listed under Technical Data. Before using these products for non-industrial applications, life-support systems, or other applications not within published specifications, consult NORGREN. Through misuse, age, or malfunction, components used in fluid power systems can fail in various modes. The system designer is warned to consider the failure modes of all component parts used in control systems and to provide adequate safeguards to prevent personal injury or damage to equipment in the event of such failure. System designers must provide a warning to end users in the system instructional manual if protection against a failure mode cannot be adequately provided. System designers and end users are cautioned to re specific warnings found in instruction sheets packed and shipped with these products. N/UK For your local Norgren Technical Sales Centre phone For your local Norgren Distributor phone IMI Norgren Limited, PO Box, Eastern Avenue, Lichfield, Staffordshire WS 6SB
Integrated PLC controllers and networking devices for electro-pneumatic systems
Integrated PLC controllers and networking devices for electro-pneumatic systems The Integrated PLC module contains a Jetter Mikro PLC capable of driving up to 6 valves on the adjacent valve manifold and
More information97100 NAMUR series, 3/2 & 5/2 Indirect solenoid actuated spool valve
9700 NAMUR series, / & / > > Port size: /4 (ISO G or NPT), NAMUR Interface > > Crossover-free switching > > Main application: Single and double acting actuators > > / way valve usable as / way valve >
More informationCompact performance. Brief description. CPV valve terminal with AS-Interface type CPV..-GE- ASI-8E8A-Z M8. English e [ ]
Compact performance Brief description CPV valve terminal with AS-Interface type CPV..-GE- ASI-8E8A-Z M8 English 8080251 2017-11e [8080244] Translation of the original instructions Documentation on the
More informationV03, V04 and V05 Series
V03, V04 and V05 Series / and 3/ Poppet Valves Electrically Actuated G 1 8, G 1 4, CNOMO and Interface Extensive range of power and orifice size options Removable coil Manifold rail for 1 to 0 valves Operating
More informationFLM DI 8 M12. Function. Fieldline Modular Device With Eight Digital Inputs. Data Sheet
Fieldline Modular Device With Eight Digital Inputs Data Sheet 697000 02/2004 This data sheet is only valid in association with the FLS FLM SYS INST UM E user manual or the user manual for your bus system
More informationAS-Interface I/O Module
AS-Interface I/O Module Construction The AS-Interface I/O module is designed as a compact, robust field module. It is composed of an electronic module (top) and a coupler module (base). Connectors (standard
More informationFieldbus Direct Key features
Key features The system Extremely compact and spacesaving design Low-cost solution for the connection of a small number of valves to a fieldbus Extremely safe, protection class up to IP65 depending on
More informationILBIB24DO16-DSUB. Inline Block IO Module for INTERBUS With 16 Digital Outputs; Bus Connection via D-SUB Connectors
Inline Block IO Module for INTERBUS With 16 Digital Outputs; Bus Connection via D-SUB Connectors AUTOMATIONWORX Data Sheet 7119_en_02 PHOENIX CONTACT - 03/2007 Description The ILB IB 24 DO16-DSUB module
More informationAdvant OCS. The Compact and Cost Effective Advant Controller. Advant Controller 210. Open Control System
Advant OCS Open Control System Advant Controller 210 The Compact and Cost Effective Advant Controller Advant Controller 210 is a small, cost-effective system belonging to the Advant Controller family.
More informationField bus connections Link structure BDC Link structure BDC, B-design. Brochure
Field bus connections, B-design Brochure Field bus connections, B-design Bus coupler with driver Direct field bus connection (BDC) Bus coupler with driver direct field bus connection Field bus protocol:
More informationDigital electropneumatic positioner
Digital electropneumatic positioner Type 879 can be combined with Compact metal housing Graphic display with backlight Easy start-up Comprehensive range of additional software functions Profibus DPV1 (optional)
More informationPHOENIX CONTACT - 11/2007. This data sheet is only valid in association with the IB IL SYS PRO UM E user manual.
INTERBUS Inline Bus Coupler; Remote Bus Connections Via D-SUB Connectors REMOTE IN BA UL RD RC DSUB LD AUTOMATIONWORX Data Sheet 6362_en_03 PHOENIX CONTACT - 11/2007 REMOTE OUT Description The bus coupler
More informationIBS ST 24 BK-T INTERBUS-S. Data Sheet. Bus Terminal Module. Product Description
IBS ST 24 BK-T Data Sheet INTERBUS-S Bus Terminal Module Data Sheet Revision A 08/994 Product Description The IBS ST 24 BK-T bus terminal module is the head station for an INTERBUS ST compact station in
More informationILBPB24DO32. Inline Block IO Module for PROFIBUS With 32 Digital Outputs. AUTOMATIONWORX Data Sheet 6889_en_04. Description
Inline Block IO Module for PROFIBUS With 32 Digital Outputs AUTOMATIONWORX Data Sheet 6889_en_04 Description PHOENIX CONTACT - 03/2007 & & ' ) The ILB PB 24 DO32 module is designed for use within a PROFIBUS
More informationRemote Process Actuation Control System AirLINE PHOENIX INLINE
Remote Process Actuation Control System AirLINE PHOENIX INLINE Type 8644 can be combined with... Fully compatible with Phoenix Inline System Combination of Fieldbus, pilot valves and I/O modules High flexibility
More informationInstallation Instructions Temperature transmitter TAA /00 06/2011
Installation Instructions Temperature transmitter TAA431 706042/00 06/2011 Contents 1 Functions and features...3 2 Installation...4 2.1 Addressing...4 2.2 Mechanical installation...4 2.3 Connection to
More informationIB ST 24 AO 4/EF. INTERBUS-ST analog output module, 4 outputs, 0-10 V, ±10 V, 0-20 ma, 4-20 ma. Data sheet. 1 Description
INTERBUS-ST analog output module, 4 outputs, 0-10 V, ±10 V, 0-20 ma, 4-20 ma Data sheet 105597_en_01 PHOENIX CONTACT 2014-10-24 1 Description The module is designed for use within an ST station. It is
More informationVersaMax IP Input Module
Module is used to accept digital input signals. Module Specifications Housing dimensions (width x height x depth) Connection style Operating temperature Storage temperature Operating/storage humidity 60mm
More informationVersaMax IP I/O Module
Module accepts four digital input signals and provides four digital outputs. It connects to a local bus that is interfaced to a Profibus-DP / PROFINET network by a Profibus Interface Unit (IC677PBI001)
More informationAbsolute Encoders Multiturn
The multiturn encoders 6 and 8, with interface and combined optical and magnetic sensor technology, offer a maximum resolution of 5 bits. These encoders are programmable via the Ezturn software. The hollow
More information26360, Inline. Technical data. Ordering information See page 2. For connector plugs see page 2 and data sheets N/en /2 5/2.
66, 87 Inline / and 5/ directional control valves NG 6 and Operation: elektromagnetic Indirectly controlled soft seal spool valves Port size: G /4 and G / For single and double operated actuators Manual
More informationSensor boxes SRBG Key features
Key features Function SRBG sensor boxes are the compact solution when it comes to electrical feedback signals and monitoring the position of process valves which are actuated with pneumatic quarter turn
More informationOperating instructions valve control box AS-i
THIS LEAFLET SHOULD BE KEPT IN A SAFE PLACE FOR REFERENCE Operating instructions valve control box AS-i 1 System description The Norgren Herion valve control box is used for controlling pneumatic swivel
More informationOperating instructions. Standstill monitor A / / 2011
Operating instructions Standstill monitor A300 UK 1 2 3 4 5 6 7 8 7390337 / 01 02 / 2011 1 2 3 4 5 6 7 8 switchpoint min max pulse/min power Made in Germany ifm electronic gmbh D 45127 Essen func. I II
More information4.7 Digital Input/Output Module 07 DC digital inputs, 8 digital outputs, 8 configurable inputs/outputs, 24 V DC, CS31 system bus
4.7 Digital Input/Output Module 16 digital inputs, 8 digital outputs, 8 configurable inputs/outputs, 4 V DC, CS31 system bus 1 3 Advant Controller 31 I/O Unit ERR Test 4 1 Fig. 4.7-1: Digital input/output
More informationControl Head for the integrated mounting on process valves
Control Head for the integrated mounting on process valves Type 8691 can be combined with Compact stainless steel design Integrated analogue valve position registration (Teach function) Coloured illuminated
More informationDigital electropneumatic positioner
Digital electropneumatic positioner Type 879 can be combined with Compact metal housing Graphic display with backlight Easy start-up Comprehensive range of additional software functions Profibus DPV1 (optional)
More informationSPCH/ Big bottle blowing block
> > Blowing block for linear and rotating blow moulding machines > > Digital position indicator - counter with four decade from 000.0 to 00.0 > > Best suited for PET bottles from 5 up to 30 litres (up
More information26360, NAMUR. Technical data
66, 87 NAMUR /-, /- and / directional control valves Operation: elektromagnetic Indirectly controlled soft seal spool valves Port size: G/ NAMUR-Interface For single and double operated actuators Manual
More information21023, 21025, 2/2 Direct solenoid actuated poppet valves
03, 05, / > > Port size: G/4, G/ > > Working from 0 bar up > > Suitable for mediumhigh vacuum down to.33 0 - mbar l/s > > Compact design > > Valves and solenoids are ATEX approved. Additional international
More informationControl head for hygienic process valves
for hygienic process valves Type can be combined with... Universal attachment for hygienic process valves Contactless position measurement system with 3 switching points (Teach-In function) Coloured status
More informationAccessories Fieldbus Box
Power cables, sensor cables, connection cables and further accessories see the EtherCAT Box chapter from page 514 Pre-assembled cables for fieldbus components include a wide range of cable assemblies.
More informationGFK-2415A March Type of sensor connection
VersaMax IP Expansion Module has four analog differential inputs that can be configured as current or voltage inputs. It connects to a local bus that is interfaced to a Profibus-DP / PROFINET network by
More informationVAL-62. Fieldbus modules FD67 Series Input, output and analog modules with IP67 ingress protection. Valves
Valves Fieldbus modules Reduced cabling and installation costs 256 I/O per node Single channel diagnostics IP67 Ingress protection Fully configurable I/O points Compact, robust construction Fieldbus nodes,
More informationInterface with: PROFIBUS, CANopen, DeviceNet, EtherNet/IP, PROFINET, EtherCAT Compatible with all Camozzi valve islands
Valve Islands > 016 > Series CX multi-serial module Series CX multi-serial module New Interface with: PROFIBUS, CANopen, DeviceNet, EtherNet/IP, PROFINET, EtherCAT Compatible with all Camozzi valve islands»»
More information80265 series, 3/2 Indirect solenoid actuated poppet valve
> > Port size: G/... G > > High flow rate > > Optionally air pilot operated > > High repeatability of switching time > > Variable valve solenoid combination Technical features Medium: Compressed air, filtered,
More informationAS-Interface Slaves. I/O Modules for Operation in the Field. Digital I/O modules IP67 - K45
Overview The large industry-proven K60 compact modules are complemented perfectly by the K45 compact module series. They round off the existing product range of smaller modules. The acknowledged advantages
More informationControl Head for the integrated mounting on process valves
Control Head for the integrated mounting on process valves Type can be combined with Compact stainless steel design Integrated analogue valve position registration (Teach function) Coloured illuminated
More information170 ADM to 60 VDC Module Base / 170 ADO Pt. Relay Out Module Base. Version 1.0
170 ADM 850 10 10 to 60 VDC Module Base / 170 ADO 830 30 6 Pt. Relay Out Module Base Version 1.0 31005197 00 Safety Information NOTICE Read these instructions carefully, and look at the equipment to become
More informationAS-i 3.0 PROFIBUS Gateways with integrated Safety Monitor
AS-i 3.0 Gateways 2 AS-i Masters, 1 PROFIBUS Slave Up to 32 release circuits up to 6 CAT4, SIL 3 safe output circuits on the Monitor safe relays or fast electronic safe outputs up to 32 independent AS-i
More informationAS-i 3.0 PROFINET-Gateways with integrated Safety Monitor
AS-i 3.0 PROFI Gateways with Master, 1 PROFI Slave Up to 32 release circuits up to 6 safe output circuits on the Monitor safe relays or fast electronic safe outputs up to 32 independent AS-i outputs Multiple
More informationThis data sheet is only valid in association with the IL SYS INST UM E user manual.
Inline analog input terminal, 4 inputs for connecting voltage signals Data sheet 8081_en_01_C01 PHOENIX CONTACT 2015-04-14 1 Description The terminal is designed for use within an Inline station. It is
More information170 ADO VDC - 32 Pt. Discrete Output Module Base
31001697 9/2010 170 ADO 350 00 24 VDC - 32 Pt. Discrete Output Module Base 27 Overview This chapter describes the 170 ADO 350 00 TSX Momentum I/O base. What's in this Chapter? This chapter contains the
More informationFlow. Flow. N/en
/ poppet valves electromagnetic actuated, directly controlled G /4 or /4 NPT Working from 0 bar up Short switching times Suited for fine vacuum down to, 0 - mbar For a.c. solenoid systems with integrated
More informationOperating pressure (bar) kv factor (m 3 /h) *3)
/ way poppet valves (stainless steel) electromagnetic actuated, directly controlled G /8, G /4 or /4 NPT Working from 0 bar up Assembled free of oil and grease Suited for fine vacuum down to,33 0 - mbar
More informationAS-i Safety Relay Output Module with Diagnostic Slave
AS-i Safety Relay Output Module with Diagnostic Slave User Manual Revision date: 2013-01-30...supports the requirements for AS-i Safety up to SIL3 Subject to modifications without notice. Generally, this
More informationAS-i 3.0 Gateways, PROFIsafe via PROFIBUS or PROFINET
safe via BUS or NET AS-i 3.0 Gateways, safe via NET or BUS safe and Safe Link in one device up to 450 devices 2 / 1 Master, NET / BUS Slave AS-i Safety input slaves report via safe AS-i Safety output slaves
More informationTRIO-PS/1AC/24DC/20. Extract from the online catalog. Order No.:
Extract from the online catalog TRIO-PS/1AC/24DC/20 Order No.: 2866381 DIN rail power supply unit, primary-switched mode, 1-phase, output: 24 V DC / 20 A Commercial data EAN 4046356046664 Pack 1 pcs. Customs
More informationAS-i 3.0 Gateways, PROFIsafe via PROFIBUS or PROFINET
safe via BUS or NET AS-i 3.0 Gateways, safe via NET or BUS safe and Safe Link in one device up to 450 devices 2 / 1 Master, NET / BUS Slave AS-i Safety input slaves report via safe AS-i Safety output slaves
More informationAS-i 3.0 PROFIBUS Gateways with integrated Safety Monitor
AS-i 3.0 Gateways 2 / 1 AS-i Master, Slave 1 AS-i Safety Monitor for 2 s Operation using a single Monitor! Monitor processes safety slaves on two s Coupling between the two networks superfluous Up to 32
More informationRemote Process Actuation Control System AirLINE PHOENIX INLINE
Remote Process Actuation Control System AirLINE PHOENIX INLINE Type 8644 can be combined with... Fully compatible with Phoenix Inline System Combination of Fieldbus, pilot valves and I/O modules High flexibility
More informationEPGG001. Fieldbus Gateway RS-232 to PROFINET. Industrial Communication. Technical Data. Part Number
Fieldbus Gateway RS-232 to PROFINET EPGG001 Part Number Easy handling Gateway from RS-232/422/485 interfaces to PROFINET With two Industrial Ethernet ports Technical Data Electrical Data Supply Voltage
More informationProximity sensors, block design
Proximity sensors, block design Proximity sensors, block design Product range overview Measuring principle Version Type Mounting Switching element function Switching Electrical connection N/O contact N/C
More informationDigital Modules AS-i in IP20, 22,5 mm
Digital Modules AS-i in 22,5 mm Cost efficient solution in IP20 (Figure similar) Figure Type Housing s digital digital voltage (sensor supply) (1) Output voltage (actuator supply) (2) AS-i connection (3)
More information21D Allfluid pressure switch, electromechanically actuated
D > > 0,... 0, bar (0,... psi), G/, / NPT > > High accuracy > > High number of switching cycles > > Microswitch approved by UL and CSA > > Fixed or adjustable hysteresis > > Shock and vibration tested
More informationTemposonics. R-Series Profibus. Absolute, Non-Contact Position Sensors. Temposonics RP and RH Stroke length mm
Temposonics Absolute, Non-Contact Position Sensors R-Series Temposonics RP and RH Stroke length 25 7600 mm Advanced Communication offers Multi-Position Measurement Rugged industrial sensor Linear and absolute
More informationAS-i / IO-Link Module, IO-Link Master with 4 IO-Link Ports
/ IO-Link Module, /IO-Link Module, IO-Link Master with 4 s fourfold IO-Link Master in one housing Power supply of s (or ) (Figure similar) Figure Type Inputs digital 4 x + 4 x + 4 x Outputs digital M12
More informationAS-i 3.0 Gateways, PROFIsafe via PROFIBUS or PROFINET
safe via BUS or NET AS-i 3.0 Gateways, safe via NET or BUS 2 / 1 Master, NET / BUS Slave AS-i Safety input slaves report via safe AS-i Safety output slaves switch via safe Up to 32 release circuits up
More informationPHOENIX CONTACT - 07/2006
Buffer module with maintenance-free capacitor-based power storage device INTERFACE Data sheet 102035_03_en PHOENIX CONTACT - 07/2006 Description Short-term mains interruptions are bridged by QUINT BUFFER,
More informationAS-i 3.0 EtherNet/IP + Modbus TCP-Gateways with integrated Safety Monitor
AS-i 3.0 -Gateways 2 / 1 AS-i Master, -Slave (1) switch integrated Up to 64 release circuits up to circuits SIL 3, cat. 4 on the Monitor, relays or fast Safe AS-i outputs are supported up to 32 independent
More informationFieldbus Gateway Type ME43
Fieldbus Gateway Type ME43 Gateway for Industrial Ethernet and Fieldbus standards Up to 128 input and 128 output variables can be assigned Easy integration in the process control system ensured through
More informationFieldgate SFG500. Technical Information. Intelligent Ethernet/PROFIBUS gateway
Technical Information Fieldgate Intelligent Ethernet/PROFIBUS gateway Application Fieldgate is a system component that provides an independent access route to a PROFIBUS network. It may be used in a variety
More information5 Fieldbus Technology
5 Fieldbus Technology Ex e / Ex i 10922E00 The s Ex e/ex i connect intrinsically safe Foundation Fieldbus H1 or Profibus PA field devices to a non-intrinsically safe / Ex e trunk. Up to four intrinsically
More informationDigital electropneumatic positioner
Digital electropneumatic positioner Type 879 can be combined with Compact and robust design Easy to start using tune function Dynamic positioning system with no air consumption in controlled state Profibus
More informationScrew terminal panels, Relay output boards, connection cables
Screw terminal panels, Relay output boards, connection cables How important are cables and terminal panels? When the PC runs important controlling and regulating tasks in a processing system, then data
More informationTROXNETCOM AS-i. Modules. Communication interface between a component and the controller. 06/2015 DE/en K
.2 X X testregistrierung TROXNETCOM AS-i Communication interface between a component and the controller The module is used to connect the control system with the components Integral AS-Interface slave
More informationFaults on the system Proximity switch connection technology:
Speed monitor for connection to a base unit from the PNOZmulti modular safety system Approvals Unit features Monitoring of 2 independent axes Connection of 2 incremental encoders or 4 proximity switches
More information170 ADI VDC - 16 Pt. Discrete Input Module Base
24 VDC - 16 Pt. Discrete Input Module Base 11 At a Glance Purpose This chapter describes the 170 ADI 340 00 TSX Momentum I/O base. In This Chapter This chapter contains the following sections: For This
More informationAI561 Analog Input Module
Ordering Data DATA SHEET AI561 Analog Input Module 1 Ordering Data Part No. Description Product Life Cycle Phase *) 1TNE 968 902 R1101 AI561, analog input module, 4 AI, U/I 1TNE 968 901 R3101 1TNE 968
More informationSiemens Spares. Preface 1. Scope of Delivery 2 SIPLUS CMS4000. Product Characteristics 3 ION PROFIBUS DP SPY T001 Installation and Maintenance 4
Preface 1 Scope of Delivery 2 Product Characteristics 3 Industrial I/O-Node ION PROFIBUS DP SPY T001 Installation and Maintenance 4 6AT8000-1BA00-5XA0 Notes on the CE Mark 5 References 6 Appendix 7 Release
More informationDC562, digital input/output module,
Ordering Data DATA SHEET DC562 Digital Input/Output Module 1 Ordering Data Part No. Description Product Life Cycle Phase *) 1SAP 231 900 R0000 1TNE 968 901 R3101 1TNE 968 901 R3102 1TNE 968 901 R3103 1TNE
More informationIB IL 24/48 DOR 2/W-XC-PAC
Inline digital output terminal, version for extreme conditions, 2 relay PDTs Data sheet 8463_en_01 PHOENIX CONTACT 2015-08-12 1 Description The terminal is designed for use within an Inline station. It
More informationField bus connections Link structure DDL Link structure DDL, bus coupler. Brochure
Brochure 2 Bus coupler with driver link structure DDL, S-design S-design Bus coupler with driver Field bus protocol: ControlNet / EtherNET/IP / MODBUS TCP / TCP/IP Stand-alone bus coupler link structure
More informationQUINT-PS AC/24DC/10
Extract from the online catalog QUINT-PS-100-240AC/24DC/10 Order No.: 2938604 DIN rail power supply unit 24 V DC/10 A, primary switched-mode, 1- phase Commercial data EAN 4017918890537 Pack 1 Pcs. Customs
More informationOperating instructions. Switching amplifier DN0210 DN / / 2015
Operating instructions Switching amplifier DN0210 DN0220 UK 80011079 / 00 01 / 2015 Contents 1 Preliminary note...4 1.1 Symbols used...4 1.2 Warning signs used...4 2 Safety instructions...5 2.1 General...5
More informationDigital electropneumatic positioner SideControl
Digital electropneumatic positioner Type 879 can be combined with Compact and robust design Easy to start using tune function Integrated diagnostic functions for valve monitoring (optional) Dynamic positioning
More information3/2 Directional control valves Direct solenoid operated poppet valves Internal thread G 1/2, 1/2 NPT or flanged with NAMUR interface
9805 / Directional control valves Direct solenoid operated poppet valves Internal thread G /, / NPT or flanged with NAMUR interface Main application: single operated actuators for plants TÜV-approval based
More informationSeries 95000, 2/2 Direct solenoid actuated poppet valve
> Port size: /4 (ISO G or NPT), G/ > Working from 0 bar up > Short switching times > Suited for fine vacuum down to,33 x 0 - mbar > For a.c. solenoid systems with integrated rectifier (40... 60 Hz) > Variable
More informationMiniAmp. Electronics & Software. Miniature Charge Amplifier. Type 5030A...
Electronics & Software MiniAmp Type 5030A... Miniature Charge Amplifier The MiniAmp Type 5030A is a single channel, industrial charge amplifier, which converts the charge signal from piezoelectric sensors
More informationOperating instructions AS-i SmartLine module AC3200 AC /00 06/2016
Operating instructions AS-i SmartLine module AC3200 AC3201 80237876/00 06/2016 Contents 1 Preliminary note...3 1.1 Symbols used...3 1.2 Warnings used...3 2 Safety instructions...3 2.1 General...3 2.2 Target
More informationTB3P/TB4P I/O PROFIBUS DP FIELDBUS MODULE FOR PNEUMATIC MANIFOLD VALVES. Pg. 1 di 14
TB3P/TB4P I/O PROFIBUS DP FIELDBUS MODULE FOR PNEUMATIC MANIFOLD VALVES Pg. 1 di 14 INDEX Legend of Symbols... 3 Conformity Declaration... 3 System Descripiton... 4 Module Specifications... 4 Installation
More informationSITOP in the SIMATIC Design
Siemens AG 2017 /2 Introduction /3 1-phase, 24 V DC (for S7-300 and ET 200M) /9 1-phase, 24 V DC (for S7-1200) /11 1-phase, 24 V DC (for S7-1500 and ET 200MP) /14 3-phase, 24 V DC (ET 200pro) Siemens KT
More informationSeries LC6D/LC6C. LJ1 LG1 LC1 LX LC6D/LC6C Switches LC6C LC6D. Series LX Dedicated Stepper Motor Driver and Positioning Driver
Series LCD To power supply Stepper Motor Driver LCD Electric Actuator Series LCC Series LX Dedicated Stepper Motor Driver and Positioning Driver Series LCD/LCC PLC Positioning unit (Not incl. To be provided
More informationProximity sensors, block-shaped Product range overview
Proximity sensors, block-shaped Product range overview Measuring Version Type Assembly Switching element function Switch output Electricalconnection principle N/C contact Cable Plug Magneto- Operating
More informationSENSICK AS-i Components. Technical Description
SENSICK AS-i Components Technical Description AS-i Applications AS-i Applications Central control of complex processes in the packaging industry with AS-i. To Control System AS-i classic field modules
More informationLVX Control Unit. Features:
Date 2013-02-28 Control Unit Features: Most parameters can be defined as required for your interfaces. You decide which information is output and how. Fast cycle times, just a few µs/beam. Maximum beam-count
More informationI/O EXPANSION MODULES
4 Trio Motion Technology 4-2 Hardware Reference Manual General Description of I/O Modules Trio Motion Technology s range of digital and analogue input/output expansion modules are designed to enable simple
More informationDigital electropneumatic Positioner SideControl
Digital electropneumatic Positioner SideControl Type 8791 BASIC can be combined with Compact and robust design Easy to start using tune function Dynamic positioning system with no air consumption in controlled
More informationAS-i / IO-Link Module, IO-Link Master with 4 IO-Link Ports
/ IO-Link Module, /IO-Link Module, IO-Link Master with 4 s fourfold IO-Link Master single in one housing Power supply of s out of AUX (or ) Figure Type Inputs digital 8x M 8x M 4 x + 4 x + Outputs digital
More informationELR W1/ 6-24DC. Extract from the online catalog. Order No.:
Extract from the online catalog ELR W1/ 6-24DC Order No.: 2982090 Illustration shows item ELR W1/ 6-24DC Electronic reversing load relay, for driving DC motors, with light indicator and protection circuit,
More informationCM592 PROFIBUS Communication Module
Ordering Data DATA SHEET CM592 PROFIBUS Communication Module 1 Ordering Data Part No. Description Product Life Cycle Phase *) 1SAP 173 200 R0001 1SAP 373 200 R0001 CM592-DP, communication module PROFIBUS
More informationAS-i 3.0 Sercos Gateways with integrated Safety Monitor
AS-i 3.0 Sercos Gateways with Safety on Sercos and Safe Link in one device up to 456 Devices Safely monitoring safety drives with Safety on Sercos 2 / 1 AS-i master, Sercos slave switch integrated (figure
More informationOperating instructions AC010S Compact AS-i E-STOP safety module
Operating instructions AC010S Compact AS-i E-STOP safety module Sachnr. 7390636_/00 05/2007 Contents Safety instructions............................. 3 Installation / Setup............................
More informationSYSMAC Remote Transistor Module
9 SYSMAC Remote Transistor Module Ultra-compact Remote I/O Modules to Match Most Applications 1 4-point, 8-point and 16-point models 1 4-point models measure 82 W x 32 D x 64.5 H mm; 8- and 16-point models
More informationRXL24.1. Room controller RXL. Communicating controller for chilled ceiling and radiator applications CC-02
s 3 878 RXL Room controller RXL24.1 Communicating controller for chilled ceiling and radiator applications CC-02 The RXL24.1 room controller is used for temperature control in individual rooms. For chilled
More informationTemposonics. R-Series Profibus. Absolute, Non-Contact Position Sensors. Temposonics RP and RH Measuring length mm
R-Series Temposonics Absolute, Non-Contact Position Sensors R-Series Temposonics RP and RH Measuring length 5-7600 mm Advanced Communication... offers Multi-Position Measurement Rugged Industrial Sensor
More informationGeneral-Purpose Photoelectric Sensor
General-Purpose Photoelectric Sensor Compact Limit Switch Style with Universal Supply FET output allows for solid state switching of AC or DC Universal AC/DC power supply Choose cable or connector types
More informationPA ROUTERS. The following criteria can be applied when choosing the network transition:
PA ROUTERS To create a smooth network transition between PROFIBUS DP and PROFIBUS PA, the SIMATIC product range offers two versions: the DP/PA coupler and the PA link. The following criteria can be applied
More informationQUINT-PS/ 1AC/24DC/ 5
Extract from the online catalog QUINT-PS/ 1AC/24DC/ 5 Order No.: 2866750 DIN rail power supply unit 24 V DC/5 A, primary switched-mode, 1- phase. The SFB technology (Selective Fuse Breaking Technology)
More informationValve terminal RE-10 with Multi-pin, AS-Interface or bus connection 4 12 valve stations, 300 Nl/min (0.305 Cv)
Type of connection = AS = B1 = B6 Order code RE-10/08-M-1-060 Series Number of stations Multi-pin: 4, 6, 8, 10, 12 Bus versions: 4, 8, 12 Electrical options M-1 = Multi-pin D-Sub plug AS3 = AS-Interface
More information