Article No.: MCS III plus. Contents. Device descripition... 2 Technical data... 2 Accessories... 2

Size: px
Start display at page:

Download "Article No.: MCS III plus. Contents. Device descripition... 2 Technical data... 2 Accessories... 2"

Transcription

1 Planning Manual Hand-held remote control Article No.: / 0 Contents Device descripition Technical data Accessories Accessories supplied Accessories (plus surcharge) Connection diagram (Ergoline Sunrise, Beauty Angel CVT 4) Connection diagram (Ergoline Essence, Ergoline Balance 440, Beauty Angel CVT 3, Beauty Angel CT 8) Overview to connection options Connection diagram (Ergoline Affinity-S / Affinity, Ergoline Balance 00, Ergoline Inspiration-S / Inspiration, Sunangel S 4, Beauty Angel C 4 sun, Beauty Angel C 34 plus ) Series from 0/ Connection diagram (Ergoline Prestige 400, Ergoline Prestige 00, Ergoline Prestige 000, Ergoline Prestige-S / Prestige, Ergoline Esprit-S / Esprit, Ergoline Open Sun Pilot, Sunangel Duo 400, Sunangel Duo S / Sunangel S, Sunangel Duo 00 Beauty Angel CHP plus,) Series from 0/ Connection diagram (Ergoline Passion-S, Ergoline Flair, Beauty Angel C 8) Hand-held remote control

2 Hand-held remote control Planning Manual C Device descripition. Display. Operating keys 3. Chip card slot Dual safety cutout switch to standards EN and A 000 sections.08 and / 0 Technical data Equipment: Relay control for connection to a professional device, with chip card reader Operating voltage: Supply from the respective device with a 7-pole plug / direct connection Max. ambient temperature: 0 to 40 C Max. relative air moisture content: 70 % Max. storage temperature: 0 to 0 C Dimensions [mm]: width x height x depth 00 x 80 x 3 Accessories Accessories supplied Accessories Article / Part No. Notes Master Card ( piece) Control line ( m) Connector plug (extra-low voltage) Accessories (plus surcharge) Accessories Article / Part No. Notes Adapter (Transformer 4 V to 30 V) e.g. for third-party units Adapter (Transformer 4 V to 30 V) only in the Ergoline Sunrise series and Beauty Angel CVT 4 Control line (0 m) Extension (Handheld remote control to transformer) Hand-held remote control

3 Planning Manual Hand-held remote control Overview to connection options with Adapter ( or ) Ergoline Prestige 400 / 00 / 000 from 0/03: see page Ergoline Prestige-S / Prestige from 0/007: see page Ergoline Esprit-S / Esprit from 0/007: see page Ergoline Affinity-S / Affinity from 0/007: see page 4 Ergoline Balance 00 see page 4 Ergoline Inspiration 00 / Inspiration 00 from 0/03: see page Ergoline Inspiration-S / Inspiration see page 4 Ergoline Passion-S see page Ergoline Flair see page Ergoline Sunrise see page 7 (000083) Ergoline Essence see page 8 Ergoline Balance 440 see page 8 Ergoline Open Sun Pilot see page Sunangel Duo 400 / Sunangel Duo 00 from 0/03: see page Sunangel Duo S / Sunangel S see page Sunangel S 4 from 0/007: see page 4 Beauty Angel C 4 sun / Beauty Angel C 34 plus see page 4 Beauty Angel C 8 see page Beauty Angel CVT 4 see page 7 (000083) Beauty Angel CVT 3 / Beauty Angel CT 8 see page 8 Beauty Angel CHP plus see page Hand-held remote control 3

4 Hand-held remote control Planning Manual Connection diagram (old X3 clamp) Series from 0/007 Ergoline Affinity-S / Affinity Ergoline Balance 00 Ergoline Inspiration-S / Inspiration Sunangel S 4 Beauty Angel C 4 sun Beauty Angel C 34 plus The plug on the hand-held remote control () must be removed. The control cable () is connected directly to the connection strip (3) of the professional device.. Hand-held remote control with micro-processor. Connection cable (control line) 3. Connection strip in professional device 4. Bridge Old X3 clamp: grey yellow 3 white 4 brown green green-yellow 07 / / 0 4 Hand-held remote control

5 Planning Manual Hand-held remote control Connection diagram (new X3 clamp) Series from 0/007 ) > 0/03 Ergoline Prestige 400 ) Ergoline Prestige 00 ) Ergoline Prestige 000 ) Ergoline Prestige-S / Prestige Ergoline Esprit-S / Esprit Ergoline Open Sun Pilot Sunangel Duo 400 ) Sunangel Duo S Sunangel S Sunangel Duo 00 ) Beauty Angel CHP plus The plug on the hand-held remote control () must be removed. The control cable () is connected directly to the connection strip (3) of the professional device.. Hand-held remote control with micro-processor. Connection cable (control line) 3. Connection strip in professional device 4. Bridge New X3 clamp: grey yellow 3 white 4 brown green green-yellow 07 / / 0 Hand-held remote control

6 Hand-held remote control Planning Manual Connection diagram (new X3 clamp) Ergoline Passion-S Ergoline Flair Beauty Angel C 8 The plug on the hand-held remote control () must be removed. The control cable () is connected directly to the connection strip (3) of the professional device.. Hand-held remote control with micro-processor. Connection cable (control line) 3. Connection strip in professional device 4. Bridge New X3 clamp: grey yellow 3 white 4 brown green green-yellow 4 07 / / 0 Hand-held remote control

7 Planning Manual Hand-held remote control Connection diagram (connection ST) Ergoline Sunrise Beauty Angel CVT 4 The connecting cable () of the manual control unit is routed through the cable channel to the top section of the professional device. The connector (3) on the manual control unit is plugged into the jack (4) of the transformer () connection cable. The control cable () from the transformer to the professional device is hooked up directly to the terminal (7) of the professional device. If the connection cable for the manual control unit with microprocessor should be extended (max. 0 m), then a flexible, shielded control cable (8 x 0. mm², item number / part number 0740) must be used.. Manual control unit with microprocessor. Manual control unit control cable 3. Control cable plug 4. Transformer jack. Transformer (30 V to 4 V, item number ). Control cable 7. Connection strip in professional device (ST) Connection ST: Wire Colour Terminal block black (Start/remote start) black (Start/remote start) 3 black 3 (Lamps ON) 4 black 4 (Lamps ON) black (N) 7 black 7 (30 V) 8 greenyellow 8 (PE) ) B = bridge B ) 43 / 0 Hand-held remote control 7

8 Hand-held remote control Planning Manual Connection diagram (ST clamp) Ergoline Essence Ergoline Balance 440 Beauty Angel CVT 3 Beauty Angel CT 8 The plug on the hand-held remote control () must be removed. The control cable () is connected directly to the connection strip (3) of the professional device.. Hand-held remote control with micro-processor. Connection cable (control line) 3. Connection strip in professional device 4. Bridge ST clamp: grey yellow 3 white 4 brown green green-yellow 07 / 0 8 Hand-held remote control

* ) Article No.: Article No.: MCS IV plus. Contents. Device descripition... 2 Technical Data... 2 Dimensions... 3 Accessories...

* ) Article No.: Article No.: MCS IV plus. Contents. Device descripition... 2 Technical Data... 2 Dimensions... 3 Accessories... Coin device MCS IV plus * ) The circuit board performance MCS is the interface between the hand-held remote control and the professional sunbed devices from Ergoline without inherent electronics (Ergoline

More information

IT power distribution Power distribution units (PDU) Basic. Versions available:

IT power distribution Power distribution units (PDU) Basic. Versions available: IT PDU Basic 1 U With its IT PDU Basic 1 U, BACHMANN provides a huge choice of PDUs in a high-quality aluminium profile. With their extremely compact size of just 1 height unit, mm in depth and 1" in width,

More information

AUDIO-GUIDE SOUND SYSTEMS

AUDIO-GUIDE SOUND SYSTEMS AUDIO-GUIDE SOUND SYSTEMS Audio Guide 1004450-00A / en / 06.2008 Foreword Audio Guide Foreword Dear Customer, This brochure will provide you with the technical requirements that will enable you to master

More information

8WH5 Combination Plug-In Terminals

8WH5 Combination Plug-In Terminals 8WH Combination Plug-In Terminals /2 Introduction / 8WH through-type terminals 1) /7 8WH hybrid through-type terminals with ipo connection /8 8WH9 plugs 1) 1) Also available as a PE version More technical

More information

Wash Light User Data. User Data - Specifications Date: 01/11/2016 Page 1/7. RGBW (White 4000k) Single Colour (R,G,B,A,W)

Wash Light User Data. User Data - Specifications Date: 01/11/2016 Page 1/7. RGBW (White 4000k) Single Colour (R,G,B,A,W) Wash Light User Data RGBW (White 4000k) Tuneable White (592nm - 6500k) Single Colour (R,G,B,A,W) RGBA (Amber 592nm) 4 Channel 4 Channel 1 Channel 4 Channel 3,360lm at source 5,352lm at source - 2,724lm

More information

BATTERY CONNECTORS VOLTAGE COLOUR COMBINATIONS DIMENSIONS OF THE BATTERY CONNECTORS BATTERY CONNECTOR: SB / S 50 BATTERY CONNECTOR: SB120 SB-SERIES

BATTERY CONNECTORS VOLTAGE COLOUR COMBINATIONS DIMENSIONS OF THE BATTERY CONNECTORS BATTERY CONNECTOR: SB / S 50 BATTERY CONNECTOR: SB120 SB-SERIES BATTERY CONNECTORS VOLTAGE COLOUR COMBINATIONS All S-connectors can function until 600V DC. When several electric devices with different voltages are used, it s recommended to choose a colour code for

More information

Operating instructions Evaluation system for flow sensors VS / / 2013

Operating instructions Evaluation system for flow sensors VS / / 2013 Operating instructions Evaluation system for flow sensors VS3000 7097 / 0 07 / 203 Contents Preliminary note...2 2 Safety instructions...3 3 Function and features... Mounting.... Mounting of the sensors...

More information

Insulated Enclosure KS 4400 with fixed or pluggable screw or cage clamp terminals

Insulated Enclosure KS 4400 with fixed or pluggable screw or cage clamp terminals Insulated Enclosure KS 4400 with fixed or pluggable screw or cage clamp terminals Technical Data Type: KS 4401 KS 4402 KS 4403 KS 4461 KS 4404 KS 440 KS 4406 Article number * ) : 00636 00637 0063987 00614

More information

MobileView Junction Box

MobileView Junction Box Installation Instructions MobileView Junction Box (Catalog Number 2727-MRJB2) English The MobileView Junction Box (2727-MRJB2) integrates the following terminals into the control system: MobileView Guard

More information

ilock control unit Wiring Manual website: phone: +(48)

ilock control unit Wiring Manual   website:   phone: +(48) ilock control unit Wiring Manual e-mail: contact@ilocksystems.com website: www.ilocksystems.com phone: +(48) 61 669 06 87 1 P a g e Table of contents 1. Basic information... 2 1.1. Scheme 01... 3 2. Fingerprint

More information

Connecting a Cisco Reader Module

Connecting a Cisco Reader Module CHAPTER 3 Overview The optional Cisco Reader Module (Figure 3-1) is similar to the Cisco Physical Access Gateway, providing the same ports for Weigand readers and other input and output devices. The Cisco

More information

Active Distributors AS-i Safety, Active Distributors AS-i

Active Distributors AS-i Safety, Active Distributors AS-i Active Distributors Safety, Active Distributors x connectors for Periphery connection via, M cable sockets or push in terminals (Figure similar) Figure Type Inputs Safety, SIL, Cat. x 9 mm, -channels Safety

More information

3081 Test Leads Test Leads Test Leads

3081 Test Leads Test Leads Test Leads 3081 Test Leads 4 mm safety plug system PVC-lead highly flexible, 0.8 mm 2 Safety plug at both ends Straight/angled, complying with Standard cable length: 500/1000/2000 mm Test Leads with Silicon-Isolation

More information

SP1 MP1 WP2 WP1. 125kHz reader models with the following prefixes: 13.56MHz reader models with the following prefixes:

SP1 MP1 WP2 WP1. 125kHz reader models with the following prefixes: 13.56MHz reader models with the following prefixes: DOC0067 Issue 1.2 Reader Wiring InSTRUCTIONS SP1 MP1 WP2 WP1 125kHz reader models with the following prefixes: 13.56MHz reader models with the following prefixes: MP1-EM1 MP1-HT1 MP1-DP1 WP1-EM1 WP1-HT1

More information

Hinged safety switches, Palladio line

Hinged safety switches, Palladio line Hinged safety switches, Palladio line Selection diagram CONTACT BLOCKS 0C 0F 0M C F M snap action snap action snap action C F M CABLE AND CONNECTORS S A P KSM KAM Cable output Cable output M connector

More information

SRI-02 Speech Recognition Interface

SRI-02 Speech Recognition Interface SRI-02 Speech Recognition Interface Data & Construction Booklet The Speech Recognition Interface SRI-02 allows one to use the SR-07 Speech Recognition Circuit to create speech controlled electrical devices.

More information

ScreenLine Accessories MB model

ScreenLine Accessories MB model ScreenLine Accessories MB model ST2121 Control Module 1 group of blinds (PC configuration) control (Potential separated) Individually configurable via Configuration Utility (PC) DIN rail mounting Dim.:

More information

Engineering Guideline. pac-carriers Type for Honeywell system Experion Series C I/O

Engineering Guideline. pac-carriers Type for Honeywell system Experion Series C I/O Engineering Guideline pac-carriers Type 995 for Honeywell system Experion Series C I/O pac-carrier Type 995 Engineering Guideline/Honeywell 04..009 pac-carrier Type 995 Integration of conventional process

More information

Technical documentation NLS-3000 NAVIGATION LIGHT CONTROL PANEL

Technical documentation NLS-3000 NAVIGATION LIGHT CONTROL PANEL Technical documentation LIGHT CONTROL PANEL For use on seagoing vessels Change status Version Date Author Checked Remark 0.1 07.08.2008 STO HN 1. Edition Page 1 of 26 Table of contents 1. Application and

More information

Fiber optic converter audio and CAN TA OPERATION MANUAL

Fiber optic converter audio and CAN TA OPERATION MANUAL Fiber optic converter audio and CAN TA-110.1 IOA110-1 March 2009 LANEX S.A., Technical support: tel. ul.ceramiczna 8, 20-150 Lublin tel. +48 81 443 96 36 Contents 1. General Characteristics.... 5 1.1.

More information

POSICHRON PCQA Mounting Sets

POSICHRON PCQA Mounting Sets PCQA Mounting Sets Mounting set PCQA-BFS1 with mounting clamps Isolation sleeve 46 Isolation strip Mounting clamp P 58 Option -BFW Mounting brackets for PCQA22 and PCQA24 Note: The option -BFW can only

More information

LineMaster 100. Continuous-line Recorder. ABB Instrumentation 10/ EN

LineMaster 100. Continuous-line Recorder. ABB Instrumentation 10/ EN LineMaster 100 Continuous-line Recorder 10/43-1.10 EN 1 to 4 measuring channels Format 144 mm x 144 mm; installed depth 250 mm Combined chart unit for roll chart (32 m) or folded chart paper (16 m) Measuring

More information

ilock control unit Wiring Manual website: phone: +(48)

ilock control unit Wiring Manual   website:   phone: +(48) ilock control unit Wiring Manual e-mail: contact@ilocksystems.com website: www.ilocksystems.com phone: +(48) 61 669 06 87 1 P a g e Table of contents 1. Basic information... 2 1.1. Scheme 01... 3 2. Fingerprint

More information

Supplementary instructions. Plug connector Harting HAN 7D. For point level sensors. Document ID: 34456

Supplementary instructions. Plug connector Harting HAN 7D. For point level sensors. Document ID: 34456 Supplementary instructions Plug connector Harting HAN 7D For point level sensors Document ID: 446 Contents Contents For your safety.... Appropriate use.... General safety instructions.... Safety instructions

More information

JUMO TYA 201 Single-Phase SCR Power Controller For controlling resistive/inductive loads

JUMO TYA 201 Single-Phase SCR Power Controller For controlling resistive/inductive loads Data sheet 709061 Page 1/21 JUMO TYA 201 Single-Phase SCR Power Controller For controlling resistive/inductive loads The JUMO TYA 201 represents a consistent further development of the JUMO power controller

More information

AS-i Safety Relay Output Module with Diagnostic Slave and 1 EDM Input

AS-i Safety Relay Output Module with Diagnostic Slave and 1 EDM Input Safety + standard I/O in one module Safety relay output with galvanically isolated contact sets, approved up to 230 V IEC 61508 SIL 3, EN ISO 13849-1/PLe Kat 4, EN 62061 SIL 3 Protection category IP20

More information

MEASURING AND TESTING INSTRUMENTS

MEASURING AND TESTING INSTRUMENTS MEASURING AND TESTING INSTRUMENTS Whether measuring temperature, current or voltage testing the right measuring tool can facilitate the everyday work. If one wants to perform several measuring tasks at

More information

Electrical Connection Technology. New Items: Autumn 2007

Electrical Connection Technology. New Items: Autumn 2007 Electrical Connection Technology New s: Autumn 2007 Contents Rail-Mounted Terminal Block Systems Volume 1 02 57 PCB Terminal Blocks and Connectors Volume 2 58 91 WINSTA WINSTA 93 97 Index of Nos. 98 102

More information

ABB Junction boxes Top solutions for surface mounting

ABB Junction boxes Top solutions for surface mounting ABB Junction boxes Top solutions for surface mounting ABB Top solutions for top professionals ABB junction boxes are the professional benchmark for their ease of installation and functionality. From the

More information

M A C 3 Wind Speed Alarm & Controller

M A C 3 Wind Speed Alarm & Controller M A C 3 Wind Speed Alarm & Controller Installation Instructions Thank you for purchasing the MAC3 wind speed alarm and controller. This manual is designed to lead you through a step-by-step process to

More information

Track Power Control. General:

Track Power Control. General: Track Power Control General: Track power is supplied by the transformers thru the TIUs mounted on five wiring panels located along the aisles and suspended from the layout facia. The power is then routed

More information

for a perfect electrical installation. The range of rail-mounted terminal blocks

for a perfect electrical installation. The range of rail-mounted terminal blocks The range of rail-mounted terminal blocks for a perfect electrical installation. The range of rail-mounted terminal blocks for a perfect electrical installation. The new standard for rail-mounted terminal

More information

JUMO TYA 202 SCR Power Controller in a three-phase economy circuit For the continous control of ohmic-inductive loads

JUMO TYA 202 SCR Power Controller in a three-phase economy circuit For the continous control of ohmic-inductive loads Data sheet 709062 Page 1/17 JUMO TYA 202 SCR Power Controller in a three-phase economy circuit For the continous control of ohmic-inductive loads The JUMO TYA 202 represents a consistent further development

More information

DC Connector. Data sheet LINAK.COM/HOMELINE

DC Connector. Data sheet LINAK.COM/HOMELINE DC Connector Data sheet LINAK.COM/HOMELINE DC Connector The DC CONNECTOR is a HOMELINE accessory making it possible to connect a variety of standard articles equipped with a DC plug to your TWINDRIVE TD3

More information

XPSMF40. Main. Safety module name. Monitoring safety detection discrete input Monitoring safety dialogue discrete output

XPSMF40. Main. Safety module name. Monitoring safety detection discrete input Monitoring safety dialogue discrete output Product datasheet Characteristics XPSMF4000 Preventa safety PLC compact - Safe Ethernet Main Range of product Product or component type Safety module name Safety module application Preventa Safety automation

More information

HFX series I First generation Hall effect joysticks

HFX series I First generation Hall effect joysticks an APEM Group Company HFX series I The HFX Series I Joystick is designed for precision finger operated applications requiring proportional control and long trouble-free life. Featuring non-contacting Hall

More information

PHOENIX CONTACT - 11/2007. This data sheet is only valid in association with the IB IL SYS PRO UM E user manual.

PHOENIX CONTACT - 11/2007. This data sheet is only valid in association with the IB IL SYS PRO UM E user manual. INTERBUS Inline Bus Coupler; Remote Bus Connections Via D-SUB Connectors REMOTE IN BA UL RD RC DSUB LD AUTOMATIONWORX Data Sheet 6362_en_03 PHOENIX CONTACT - 11/2007 REMOTE OUT Description The bus coupler

More information

SpectraDim64 from software version: V2.6 Released: V1.0 - Rev A

SpectraDim64 from software version: V2.6 Released: V1.0 - Rev A Short instruction SpectraDim64 from software version: V2.6 Released: 04-2017 - V1.0 - Rev A Page 1 Overview DMX Modes You can choose between 6 DMX modes each designed for different applications and preferences:

More information

VersaPoint I/O Module

VersaPoint I/O Module Output 24VDC Positive Logic 0.5A 14 Points Module is used to output 24VDC digital signals. Module Specifications Housing dimensions (width x height x depth) Connection style Operating temperature 48.8mm

More information

SMARTSCAN INFORMATION

SMARTSCAN INFORMATION SMARTSCAN INFORMATION RY4 SERIES SAFETY RELAYS HANDBOOK Smartscan Ltd, Pywell Road, CORBY, NN17 5XJ, UK, Tel: +44 (0) 1536 401313, Fax: +44 (0) 1536 268954, Email: sales@smartscan.com, www.smartscan.co.uk

More information

Datasheet AZM 161 Z ST1 AS RA

Datasheet AZM 161 Z ST1 AS RA 25.10.2016 10:35:58h Datasheet AZM 161 Z ST1 AS RA AS interface safety at work / Safety switchgear / Solenoid interlock / AZM 161 AS Preferred typ Solenoid interlock Thermoplastic enclosure High holding

More information

AS-i / IO-Link Module, IO-Link Master with 4 IO-Link Ports

AS-i / IO-Link Module, IO-Link Master with 4 IO-Link Ports / IO-Link Module, /IO-Link Module, IO-Link Master with 4 s fourfold IO-Link Master in one housing Power supply of s (or ) (Figure similar) Figure Type Inputs digital 4 x + 4 x + 4 x Outputs digital M12

More information

Operating instructions. Switching amplifier DN0210 DN / / 2015

Operating instructions. Switching amplifier DN0210 DN / / 2015 Operating instructions Switching amplifier DN0210 DN0220 UK 80011079 / 00 01 / 2015 Contents 1 Preliminary note...4 1.1 Symbols used...4 1.2 Warning signs used...4 2 Safety instructions...5 2.1 General...5

More information

Single Door Standalone Access Control User Manual

Single Door Standalone Access Control User Manual Single Door Standalone Access Control User Manual Reading this manual carefully before install and use the device 1. Packing List Name Quantity Remarks Keypad User manual Screw driver Rubber plug Self

More information

Electrical Interconnection

Electrical Interconnection Electrical Interconnection Edition 208/ Rail-Mount Terminal Block Systems Full Line Catalog, Volume Edition 207/208 PCB Terminal Blocks and Connectors Full Line Catalog, Volume 2 Edition 207/208 2 Automation

More information

Analog Modules AS-i, IP67, M12

Analog Modules AS-i, IP67, M12 Analog Modules, M12 2 x 2 connectors for compact housing, IP67 (Figure similar) Figure Type Inputs analog Outputs analog M12 connection Input voltage (sensor supply) Output voltage (actuator supply) (2)

More information

GAT NET.Controller 7000 Control unit for the GAT NET.Lock 7000

GAT NET.Controller 7000 Control unit for the GAT NET.Lock 7000 GAT NET.Controller 7000 Control unit for the GAT NET.Lock 7000 Application The (master controller) and S 7000 (slave controller) control units are used to connect and control the GAT NET. Lock 7000 electronic

More information

TROXNETCOM AS-i. Modules. Communication interface between a component and the controller. 06/2015 DE/en K

TROXNETCOM AS-i. Modules. Communication interface between a component and the controller. 06/2015 DE/en K .2 X X testregistrierung TROXNETCOM AS-i Communication interface between a component and the controller The module is used to connect the control system with the components Integral AS-Interface slave

More information

Operating Instructions 12/2010 MN Z-EN XV-152 MICRO PANEL

Operating Instructions 12/2010 MN Z-EN XV-152 MICRO PANEL Operating Instructions 12/2010 MN04802006Z-EN MICRO PANEL 2 Device description 2.3 Device versions 2.3 Device versions Fig. 1 MICRO PANELs are available in the following versions: Basic device Display

More information

Smart Monitoring System compact, secure, efficient

Smart Monitoring System compact, secure, efficient Smart Monitoring System compact, secure, efficient Transparency for more efficiency Continuously record and monitor the energy consumption of plant and machinery Visualise data on a display or through

More information

AS-i Safety Output Module, IP20

AS-i Safety Output Module, IP20 a AS-i Safety Output Module Safe outputs and standard inputs in one module Protection category IP20 Figure Housing Inputs digital Outputs Safety, SIL3, cat.4 Input voltage (sensor supply) 1 Output voltage

More information

MANUAL VAA-2E2A-G12-SAJ/EA2L Original Instructions Version 1.0

MANUAL VAA-2E2A-G12-SAJ/EA2L Original Instructions Version 1.0 FACTORY AUTOMATION MANUAL VAA-2E2A-G12-SAJ/EA2L Original Instructions Version 1.0 SAFETY AT WORK With regard to the supply of products, the current issue of the following document is applicable: The General

More information

Power distribution systems - accessories

Power distribution systems - accessories Connections and terminals Line terminal X 221 3 01 Power-D-Box with sockets pre-wired Line terminal (max. 63 A) X 221 3 01 14.551 max. tightening torque 3.0 Nm 15.591 busbar X1, X2 blade terminals 6.3

More information

RH and Air Temperature Sensor

RH and Air Temperature Sensor Addendum to RHT3nl-CA Technical Manual RH and Air Temperature Sensor type RHT4nl-02 RHT4-UM-2 Delta-T Devices Ltd Notices Copyright All rights reserved. Under the copyright laws, this manual may not be

More information

Data Sheet. Thumbwheel Switch Multiswitch, Series G

Data Sheet. Thumbwheel Switch Multiswitch, Series G Data Sheet Thumbwheel Switch Multiswitch, Series G Compact design Discretionary configuration and subdivision of switching modules Switch for front mounting Simple assembly Precise reading of the set values

More information

MAC3 Wind Speed Alarm & Controller. Installation Instructions

MAC3 Wind Speed Alarm & Controller. Installation Instructions MAC3 Wind Speed Alarm & Controller Installation Instructions Table of Contents Overview... 3 Installation... 3 Optional Equipment... 10 Dual Sensor Operation... 10 Other Optional Equipment... 10 Operation

More information

BS 287 DUAL CHANNEL POWER SUPPLY. User Manual. January 2017 V1.0

BS 287 DUAL CHANNEL POWER SUPPLY. User Manual. January 2017 V1.0 BS 287 DUAL CHANNEL POWER SUPPLY User Manual January 2017 V1.0 Table of contents 1.0 SAFETY INSTRUCTIONS... 3 2.0 GENERAL DESCRIPTION PS 289... 4 3.0 MECHANICAL INSTALLATION... 5 4.0 MAINS POWER & SAFETY

More information

Valve terminal RE-10 with Multi-pin, AS-Interface or bus connection 4 12 valve stations, 300 Nl/min (0.305 Cv)

Valve terminal RE-10 with Multi-pin, AS-Interface or bus connection 4 12 valve stations, 300 Nl/min (0.305 Cv) Type of connection = AS = B1 = B6 Order code RE-10/08-M-1-060 Series Number of stations Multi-pin: 4, 6, 8, 10, 12 Bus versions: 4, 8, 12 Electrical options M-1 = Multi-pin D-Sub plug AS3 = AS-Interface

More information

INTERCOM AMBULANCE/RESCUE VEHICLE MODEL ICA100 SURFACE MOUNT SERIES MODELS ICA200, ICA300 FLUSH MOUNT SERIES MODELS ICA400, ICA500

INTERCOM AMBULANCE/RESCUE VEHICLE MODEL ICA100 SURFACE MOUNT SERIES MODELS ICA200, ICA300 FLUSH MOUNT SERIES MODELS ICA400, ICA500 Document Number: XE-ICA1PM-R0A ICA100 Rev171109 INTERCOM AMBULANCE/RESCUE VEHICLE MODEL ICA100 SURFACE MOUNT SERIES MODELS ICA200, ICA300 FLUSH MOUNT SERIES MODELS ICA400, ICA500 ICA100 ICA200/300 ICA400/500

More information

Safety Light Grid Orion2 Extended

Safety Light Grid Orion2 Extended Safety Light Grid Orion Extended Orion Extended is a compact light grid for access protection in muting applications. The light grid has -4 beams and is intended for body detection. Cost effective solution

More information

One Phase Power Distribution Block

One Phase Power Distribution Block Quick mounting and wiring Blocks fit with other DIN Rail mountable modular devices (height 95mm, depth 44.5mm) Accessories increase the number of outputs with only one input (applies only to and ) No caps

More information

Multitronic. Technical data

Multitronic. Technical data Multitronic EMC Aluminium enclosure system for MCR technology Integrated guide grooves for PCB s External mounting slots with spring nuts Technical data Material: DIN EN 573 EN AW-AlMgSi Ingress protection:

More information

Wiring Diagram and Programming Instructions for MAW6 Digital Keypad and Proximity Card/F reader

Wiring Diagram and Programming Instructions for MAW6 Digital Keypad and Proximity Card/F reader Wiring Diagram and Programming Instructions for MAW6 Digital Keypad and Proximity Card/F reader www.grantsautomation.com.au grant@grantsautomation.com.au Wiring Diagrams for MAW6 Digital Keypad For Pedestrian

More information

InForm Superstructures

InForm Superstructures Advantages InForm racks are fitted between the vertical profiles and thus ensure a generous amount of open working table surface. Devices are installed directly in the 3HU and 6HU racks, additional devices

More information

Fork Sensors. catalogue

Fork Sensors. catalogue Fork Sensors catalogue 2/3 Products FC forks Sensori capacitivi Fork sensors Photoelectric fork sensors for object detection FC5 p.6 FC6 p.12 Photoelectric fork sensors for labelling detection FC7 p.18

More information

Installation Instructions 4291 and 4292 Keypads

Installation Instructions 4291 and 4292 Keypads Installation Instructions 4291 and 4292 Keypads A6851J 02/11 Copyright 2011, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the

More information

the Interactive Catalog

the Interactive Catalog Interactive Catalog Supplements Catalog PDFs If you need detailed product information, or help choosing the right product for your application, see our Interactive Catalog Use the Interactive Catalog to

More information

MBP68300 SERIES. AC-distribution, Static Switch and Manual Bypass for DAC60000 Dual Inverters. BPU69000 Dual External static switch Plug-in unit

MBP68300 SERIES. AC-distribution, Static Switch and Manual Bypass for DAC60000 Dual Inverters. BPU69000 Dual External static switch Plug-in unit MBP68300 SERIES AC-distribution, Static Switch and Manual Bypass for DAC60000 Dual Inverters Modular Construction AC-distribution 3pcs of MCBs Manual bypass switch BPU69000 Dual External static switch

More information

Connect. Electricians' tools, consumables and enclosures x 210.0mm x 210.0mm. 26.0mm. 6.0mm. 6.0mm. 6.0mm. 12.0mm.

Connect. Electricians' tools, consumables and enclosures x 210.0mm x 210.0mm. 26.0mm. 6.0mm. 6.0mm. 6.0mm. 12.0mm. Connect Electricians' tools, consumables and enclosures Tooling and consumables which includes hand tools, crimping tools and solar tools for MC3 & MC4 connectors, electrical insulation tapes, cable pulling

More information

CTT. Standard equipment. ATP color NP. ø5 (red, blue, white, black, green, and yellow) 1 2 (6P, 8P) Applicable plugs ATP-A,ATQ-A PTT

CTT. Standard equipment. ATP color NP. ø5 (red, blue, white, black, green, and yellow) 1 2 (6P, 8P) Applicable plugs ATP-A,ATQ-A PTT INSERTION TYPE TEST TERMINS STNDRD MODES (TERMIN) TT- -TYPE (For current) Circuit opening prevention type CTT 19 44 20 0 11.5 7 6 (7.) 12 10 8 6 4 2 11 9 7 5 1 M.5 7 9 48 57 75 9 Standard equipment Min.

More information

Energetic diffuse reflection light scanner. Dimensioned drawing

Energetic diffuse reflection light scanner. Dimensioned drawing Energetic diffuse reflection light scanner Dimensioned drawing We reserve the right to make changes 93_c3gb.fm Part No. 51 1168 1-3 V DC 5 17mm 1mm Infrared light Background suppression through appropriate

More information

u::lux NetCon & u::lux NetCon Power

u::lux NetCon & u::lux NetCon Power u::lux NetCon & u::lux NetCon Power Manual www.u-lux.com office@u-lux.com Tel: +43/662/450 351-13 Fax: +43/662/450 351-16 u::lux GmbH Rechtes Salzachufer 42 5020 Salzburg Austria Contents General Information...

More information

Room Controllers. SC3000 Relay Pack

Room Controllers. SC3000 Relay Pack Compatible with SmartStruxure solution SmartStruxure Lite solution Room Controllers SC3000 Relay Pack The SC3000 is a relay pack for line-voltage fan coil units. The device is used with SER7300 and SER8300

More information

GRASSO SYSTEM CONTROL

GRASSO SYSTEM CONTROL Control device for Packages and Chillers with screw compressors Product information 09.2002/ 2 638630_pi gsc gbr.doc Copyright GmbH Refrigeration Technology The contents of this documentation and the enclosed

More information

Wireless. Wireless. Datasheet. Wireless 1-10V Bridge Box

Wireless. Wireless. Datasheet. Wireless 1-10V Bridge Box Wireless Wireless 1-10V Bridge Box 929001461462 Datasheet Wireless Wireless 1-10V Bridge Box The wireless 1-10V bridge box has 1-10v analog voltage output interface, which can be connected with the drive

More information

Safety Light Curtains GuardShield Remote Teach

Safety Light Curtains GuardShield Remote Teach Specifications Presence Sensing Safety Devices Description The system provides a remote means of changing a fixed blanking configuration within the GuardShield safety light curtain. This keyswitch box

More information

AS-i / IO-Link Module, IO-Link Master with 4 IO-Link Ports

AS-i / IO-Link Module, IO-Link Master with 4 IO-Link Ports / IO-Link Module, /IO-Link Module, IO-Link Master with 4 s fourfold IO-Link Master single in one housing Power supply of s out of AUX (or ) Figure Type Inputs digital 8x M 8x M 4 x + 4 x + Outputs digital

More information

EC07 EC63. Compatible actuators: ERL2 ESD2. How to order EC 07 B. Series. B Installation. method

EC07 EC63. Compatible actuators: ERL2 ESD2. How to order EC 07 B. Series. B Installation. method Controller EC07 EC63 Compatible actuators: ERL ESD Features Compact, light weight and thin (Body width 35mm) Can be set without manual Perfect installation compatibility with actuator PC software available

More information

MODULES FOR SAFETY AND MONITORING

MODULES FOR SAFETY AND MONITORING MODULES FOR SAFETY AND MONITORING Woertz AG Hofackerstrasse 47, P.O. Box 948, CH-43 Muttenz, Switzerland Tel. ++4 6 / 466 33 33, Fax ++4 6 / 46 96 06 http://www.woertz.ch Woertz-USA 5 Discovery Drive,

More information

Data Sheet. Thumbwheel Switch Multiswitch, Series B

Data Sheet. Thumbwheel Switch Multiswitch, Series B Data Sheet Thumbwheel Switch Multiswitch, Series B Compact design Discretionary configuration and subdivision of switching modules Switch for front mounting Simple assembly Precise reading of the set values

More information

accessories cable sockets SENSORFLEX single side ready-made

accessories cable sockets SENSORFLEX single side ready-made cable sockets 1000 design 2m 5m 10m 20m connector M8 M8 3-pin 4-pin 3-pin 4-pin 5-pin 8-pin oil resistant and suitable for trailing chain black PUR cable, halogen- and silicone-free IP67 system of protection

More information

InForm Superstructures

InForm Superstructures Advantages InForm racks are fitted between the vertical profiles and thus ensure a generous amount of open working table surface. Devices are installed directly in the 3HU and 6HU racks, additional devices

More information

Three-position. device during trouble shooting, the safest solution. programming and testing. Three-position devices in different versions.

Three-position. device during trouble shooting, the safest solution. programming and testing. Three-position devices in different versions. Three-position the safest solution device during trouble shooting, programming and testing Why three-positions? An operator who is under pressure must be able to give a stop signal, whether in panic he/she

More information

Data Sheet for Joysticks

Data Sheet for Joysticks Shallow installation depth < 26 mm Service-friendly due to connectors Available interfaces include USB, Dual Output and Voltage Regulator Ideally suited for applications in CCTV, robotics, medical technology

More information

LUMOTAST FK. General data. Content. Pushbuttons 1-9

LUMOTAST FK. General data. Content. Pushbuttons 1-9 General data TAST illuminated pushbutton range Illuminable pushbuttons and signal lamps with lamp socket T /T / 4. Please order lamps / LEDs separately. Mounting hole diameter 6.2 mm 42 V/00 ma max. Water-jet

More information

1 IF-810 or IF-811 Terminal (Slave) 2 Intended Use. 3 Assembly and Installation _V IF-810/IF-811

1 IF-810 or IF-811 Terminal (Slave) 2 Intended Use. 3 Assembly and Installation _V IF-810/IF-811 95-10326_V2016-10-20 IF-810/IF-811 1 IF-810 or IF-811 Terminal (Slave) Thank you for choosing an Interflex system. With an IF-810 or IF-811 terminal (slave), you have purchased a reliable device for capturing

More information

Meridian External Alerter and Recording Interface

Meridian External Alerter and Recording Interface Version française incluse. Versión española incluída. Meridian External Alerter and Recording Interface Installation and Application Guide Meridian External Alerter and Recording Interface Installation

More information

1 IF-812 or IF-815 Terminal (Slave) 2 Intended Use. 3 Assembly and Installation _V IF-812/IF-815

1 IF-812 or IF-815 Terminal (Slave) 2 Intended Use. 3 Assembly and Installation _V IF-812/IF-815 95-10324_V2016-11-23 IF-812/IF-815 1 IF-812 or IF-815 Terminal (Slave) Thank you for choosing an Interflex system. With an IF-812 or IF-815 terminal (slave), you have purchased a reliable device for capturing

More information

Installation instructions Diagnostic electronics for vibration sensors VSE / / 2007

Installation instructions Diagnostic electronics for vibration sensors VSE / / 2007 Installation instructions Diagnostic electronics for vibration sensors UK VSE00 70406 / 00 07 / 2007 Contents Safety instructions 3 Function and features 4 Mounting 4 Mounting of the sensors 5 Electrical

More information

For situations susceptible to interference and safety-related applications

For situations susceptible to interference and safety-related applications IEC 60947-5-2 Product description Multi-pole shielded circular connectors. Design according to DIN 43651, all-metal construction, used for control and measurement systems. Connection of shielded cables

More information

TOPJOB S Sensor/Actuator Terminal Blocks with Push-in CAGE CLAMP Reliability

TOPJOB S Sensor/Actuator Terminal Blocks with Push-in CAGE CLAMP Reliability TOPJOB S Sensor/Actuator Terminal Blocks with Push-in CAGE CLAMP Reliability TOPJOB S SEND THE RIGHT SIGNALS TOPJOB S Sensor/Actuator Terminal Blocks with Push-in CAGE CLAMP Reliability TWO IN ONE. WITH

More information

B a e m W M v o i v n i g H a e d L g i h g t U E S R M N A U N A U L

B a e m W M v o i v n i g H a e d L g i h g t U E S R M N A U N A U L Beam 200W Moving Head Light USER MANUAL 200W Beam Light Manual 1.Safety Information 3 2.Installation and Startup 5 3.Menu settings 9 4.Technical Information 10 5.Channel function 11 1 Unpacking Inspection

More information

Strain gauge Measuring Amplifier GSV-1A8. Instruction manual GSV-1A8, GSV-1A8USB, GSV-1A16USB

Strain gauge Measuring Amplifier GSV-1A8. Instruction manual GSV-1A8, GSV-1A8USB, GSV-1A16USB Strain gauge Measuring Amplifier GSV-1A8 Instruction manual GSV-1A8, GSV-1A8USB, GSV-1A16USB GSV-1A8USB SubD1 (front side) GSV-1A8USB M12 (front side) GSV-1A16USB (rear side) GSV-1A8USB K6D (front side)

More information

PTC/PT100 board 2.0 Option

PTC/PT100 board 2.0 Option PTC/PT100 board 2.0 Option Instruction Manual - English PTC/PT100 board 2.0 Option Instruction Manual - English Document number: 01-3873-01 Edition: r1 Date of release: 2006-10-30 Copyright Emotron AB

More information

Pile Driver Weld Immune Sensors

Pile Driver Weld Immune Sensors DC... 190 8, 12, 18, and 30 mm Diameter... 190 3- and 4-Wire DC... 192 8, 12, 18, and 30 mm Diameter... 192 AC/DC... 194 12, 18, and 30 mm Diameter... 194 Pile Driver Sensors P+F s weld immune Pile Driver

More information

INSTALLATION MANUAL For authorized service personnel only.

INSTALLATION MANUAL For authorized service personnel only. AIR CONDITIONER SIMPLE REMOTE CONTROLLER (WIRED TYPE) UTY-RSNUM INSTALLATION MANUAL For authorized service personnel only. English Français Español Contents. SAFETY PRECAUTIONS...2 2. ACCESSORIES...2 3.

More information

Access Terminal IF-800

Access Terminal IF-800 95-10287 IF-800_1312_3 Access Terminal IF-800 1 Slave Terminal IF-800 Thank you for using a terminal of the series IF-800 for recording access data. Scope of Delivery: Slave terminal IF-800. I/O controller

More information

Interface Relay CRINT-1x

Interface Relay CRINT-1x Interface Relay CRINT-1x 1 Features Space saving interface relay to combine with PLCs Coil voltage UC12, 24, 48, 60, 110-125, 220-240V Integrated protection circuit Relay is replaceable separately Available

More information

Product and functional description. Application Program. instabus EIB Technical product information. April (6 x AC 230 V / 0,05 A)

Product and functional description. Application Program. instabus EIB Technical product information. April (6 x AC 230 V / 0,05 A) Product and functional description also functions if the bus cable is not connected or if the bus communication fails. After a long push button action (> 2 s), the other valve group is selected. The yellow

More information

PI84 with socket GZM80 interface relays

PI84 with socket GZM80 interface relays RM84 + GZM80 Contact data Number and type of contacts Contact material Rated / max. switching voltage Min. switching voltage Rated load (capacity) Min. switching current Max. inrush current Rated current

More information