Float switch For the process industry
|
|
- Kathryn O’Brien’
- 6 years ago
- Views:
Transcription
1 Level measurement Float switch For the process industry Model FLS (models with E approval: 60, AL-ADF) KSR data sheet LM for further approvals see page 3 Applications Level measurement for almost all liquid media Pump and level control and monitoring of distinct filling levels Chemical, petrochemical industry, natural gas, offshore, shipbuilding, machine building, power generating equipment, power plants Process water and drinking water treatment, food and beverage industry Special features Large range of application due to the simple, proven functional principle For harsh operating conditions, long service life Operating limits: - Operating temperature: T = C - Operating pressure: P = Vacuum up to 40 bar - Limit density: ρ 300 kg/m 3 Wide variety of different electrical connections, process connections and materials Eplosion-protected versions Description A float with a permanent magnet moves reliably along with the liquid level on a guide tube. Within the guide tube is fitted a reed contact (inert gas contact), which is energised, through the non-magnetic walls of the float and guide tube, by the approach of the float magnet. By using a magnet and reed contact the switching operation is non-contact, free from wear and needs no power supply. The contacts are potentialfree. Float switches are also available with multiple switch points. Fig. left: Stainless steel version, mounting thread, model FLS-S Fig. right: Plastic version, flange connection, model FLS-P The switching functions always refer to a rising liquid level: Normally open, normally closed or change-over contact. Through the use of a float for a ma. of 2 switch points a bistable switch behaviour can be achieved, meaning that the switching status also remains available, when the filling level continues to rise above or drop below the switch point. The float switch is simple to mount and maintenance-free, so the costs of mounting, commissioning and operation are low. KSR data sheet LM /2017 Page 1 of 20 Data sheets showing similar products: Float switch, horizontal installation; model HLS; see data sheet LM Float switch, lateral installation with eternal chamber; model ELS; see data sheet LM A division of the WIKA group
2 Further special features Process connection, guide tube and float from stainless steel , plastic or Buna Universal signal processing: direct to a PLC is possible, NAMUR connection, signal amplification / contact protection relays Works independently of foaming, conductivity, dielectricity, pressure, vacuum, temperature, vapours, condensation, bubble formation, boiling effects and vibrations Multiple functionality in a single instrument - up to 8 potential-free contacts Eact repeatability of the switch points Float switches qualify as simple apparatus in accordance with EN section 5.7 and can be installed in zone 1 hazardous areas without certification, so long as the equipment is operated in a certified intrinsically safe circuit with a minimum eplosion protection of E ib. Options Customer-specific solutions Special versions for interface layer detection -ρ 100 kg/m 3 Process connection, guide tube and float from stainless steel , , titanium, Hastelloy (others on request) Model overview Model Description Materials FLS-SE FLS-SF FLS-SA FLS-SB FLS-SBI (60) FLS-SAD FLS-SBD (AL-ADF) FLS-ME FLS-MB FLS-PF FLS-PA FLS-HE FLS-HA FLS-HA3 Stainless steel (316Ti) (316L) (316L) (316Ti) / PP (316Ti) / PA (316Ti) / Ms (316Ti) / Buna Standard version, cable connection, safety etra-low voltage Standard version, cable connection, low voltage Standard version, connection housing or connector, low voltage Standard version, connection housing or connector, safety etra-low voltage Intrinsically safe, E i Flameproof enclosure, E d Miniature design, cable connection, safety etra-low voltage Miniature design, connection housing or connector, safety etra-low voltage Plastic version, cable connection, low voltage Plastic version, connection housing or connector, low voltage Pharmaceutical version, cable connection, safety etra-low voltage Pharmaceutical version, connection housing, low voltage Sterile version (3-A), connection housing, low voltage Titanium (grade 2) PVC / PP / PVDF Page 2 of 20 KSR data sheet LM /2017
3 TYPE APPROVED Temperature range (process) Models FLS-SE, FLS-SF, FLS-HE C Models FLS-SA, FLS-SB C Models FLS-SI (60) C Models FLS-SD (AL-ADF) C Models FLS-M C Models FLS-P C Models FLS-HA, FLS-HA C Approvals Model FLS-S Logo Description Country EU declaration of conformity European Union Low voltage directive RoHS directive ATEX directive (option) Hazardous areas - E i Zone 0 Zone 21 - E d Zone 1 Zone 21 II 1/2G E ia IIC T3... T6 Ga/Gb II 2D E ib IIIC T80 C Db II 2G E d IIC T6 Gb II 2D E tb IIIC T80 C Db IECE (option) Hazardous areas - E d Zone 1 E d IIC T6 E td A21 IP65 T80 C EAC EMC directive and low voltage directive No. RU Д-DE.A301.B Hazardous areas No. RU C-DE.ГБ08.B PESO Hazardous areas No. A/P/HQ/MH/104/3293 / P DNV GL Ships, shipbuilding (e.g. offshore) Hazardous areas No. TAA00000KZ ABS Ships, shipbuilding (e.g. offshore) No. 16-HG PDA Hazardous areas No. 16-HG PDA / KEMA 01 ATEX 1053 X Bureau Veritas Ships, shipbuilding No /H0 und 04568/G0 Lloyd s Register Ships, shipbuilding (e.g. offshore) No. 07/20006 (E2) - DIBt Safety (e.g. electr. safety, overpressure,...) Overflow control per German Water Resources Act (WHG) 19 No. Z No. KEMA 01 ATEX1053 X No. TÜV 13 ATEX 7399 X No. IECE TUR X International Eurasian Economic Community India International International International International Germany KSR data sheet LM /2017 Page 3 of 20
4 Model FLS-H Logo Description Country EU declaration of conformity Low voltage directive RoHS directive EAC EMC directive and low voltage directive No. RU Д-DE.A301.B A (only model FLS-HA3) Sanitary Standard No European Union Eurasian Economic Community USA Model FLS-P Logo Description Country EU declaration of conformity Low voltage directive RoHS directive European Union EAC EMC directive and low voltage directive No. RU Д-DE.A301.B Approvals and certificates, see website Eurasian Economic Community Application eamples Full detector (E i) intrinsically safe intrinsically safe Intrinsically safe relay e.g. KFD2-SR2-E2.W Intrinsically safe relay e.g. KFD2-SR2-E2.W Hazardous area Non-hazardous area Hazardous area Non-hazardous area Level control (min/ma control) Contact protection relay e.g. KFD2-ER-1.6 Contact protection relay e.g. KFD2-ER-1.6 Page 4 of 20 KSR data sheet LM /2017
5 Float switch, standard version with connection housing or connector Models FLS-SA, FLS-SB Process connection, guide tube and float from stainless steel (316Ti) M201,5 Mounting thread Flange housing SW 30 or SW 36 L 3 =... L 2 =... Float Ø Electrical connection Process connection Guide tube diameter Guide tube length L Float Temperature range Standard version High-temperature version Low-temperature version Switching function Ma. number of contacts Switch position Distance between switch points Switching power Normally open, normally closed Change-over Model FLS-SA, low voltage Model FLS-SB, safety etra-low voltage housing Aluminium mm, with 1 contact Aluminium mm, 2 or more contacts Coupler connector Option: Polypropylene, polyester, stainless steel Mounting thread downwards G 1 1/2" or G 2" Mounting flange - DIN DN DN 200, PN 6... PN DIN EN DN DN 200, PN 6... PN ANSI 2"... 8", Class mm / 14 mm / 18 mm 3,000 mm for guide tube diameter 12 or 14 mm 6,000 mm for guide tube diameter 18 mm Material: Stainless steel (option: Buna (NBR), titanium) Float diameter: mm Float selection depending on guide tube diameter and process conditions (see page 17, 18, 19) C C C Observe the temperature range of the float and the connection housing Alternatively normally open (NO), normally closed (NC) or change-over (SPDT) contact - on rising level 6 NO or NC, or 4 SPDT Dimensions L1, L2, L3... (from sealing face, starting from top) Minimum 20 mm (depending on the selection of the float and the contacts) AC 230 V; 100 VA; 1 A DC 230 V; 50 W; 0.5 A AC 230 V; 40 VA; 1 A DC 230 V; 20 W; 0.5 A Mounting position Vertical ±30 Ingress protection up to IP66 or IP68 per IEC/EN (depending on version) AC < 50 V; 100 VA; 1 A DC < 75 V; 50 W; 0.5 A AC < 50 V; 40 VA; 1 A DC < 75 V; 20 W; 0.5 A KSR data sheet LM /2017 Page 5 of 20
6 Float switch, standard version with cable connection Models FLS-SE, FLS-SF Process connection, guide tube and float from stainless steel (316Ti) cable SW 22 or SW 27 L 2 = % display L 3 =... Float Ø Model FLS-SF, low voltage Model FLS-SE, safety etra-low voltage Electrical connection cable PVC Silicone PUR Process connection Mounting thread upwards: G ⅜" or G ½" Guide tube diameter 12 mm / 14 mm / 18 mm Guide tube length L 3,000 mm for guide tube diameter 12 or 14 mm 6,000 mm for guide tube diameter 18 mm Float Material: Stainless steel (option: Buna (NBR), titanium) Float diameter: mm Float selection depending on guide tube diameter and process conditions (see page 17, 18, 19) Temperature range PVC/PUR cable C Silicone cable C Observe the temperature range of the float Switching function Alternatively normally open (NO), normally closed (NC) or change-over (SPDT) contact - on rising level Ma. number of contacts 6 NO or NC, or 4 SPDT for PVC and PUR cable 5 NO or NC, or 3 SPDT for silicone cable Switch position Dimensions L1, L2, L3... (from sealing face, starting from top) Distance between switch points Minimum 20 mm (depending on the selection of the float and the contacts) Switching power Normally open, normally closed Change-over AC 230 V; 100 VA; 1 A DC 230 V; 50 W; 0.5 A AC 230 V; 40 VA; 1 A DC 230 V; 20 W; 0.5 A Mounting position Vertical ±30 Ingress protection up to IP66 or IP68 per IEC/EN (depending on version) AC < 50 V; 100 VA; 1 A DC < 75 V; 50 W; 0.5 A AC < 50 V; 40 VA; 1 A DC < 75 V; 20 W; 0.5 A Page 6 of 20 KSR data sheet LM /2017
7 Float switch, eplosion-protected version E i, intrinsically safe Model FLS-SBI (60) KEMA 01 ATEX 1053 X (II 1/2G E ia IIC T3... T6 Ga/Gb or II 2D E ib IIIC T80 C Db) Process connection, guide tube and float from stainless steel (316Ti) M201,5 Mounting thread Flange housing SW 30 or SW 36 L 3 =... L 2 =... Float Ø Electrical connection Process connection Guide tube diameter Guide tube length L Float Temperature class Process temperature Ambient temperature Switching function Ma. number of contacts Switch position Distance between switch points Switching power Model FLS-SBI housing: Aluminium Option: Polyester, stainless steel Mounting thread downwards G 1 1/2" or G 2" Mounting flange - DIN DN DN 200, PN 6... PN DIN EN 1092 DN DN 200, PN 6... PN ANSI 2"... 8", Class mm / 14 mm / 18 mm 3,000 mm for guide tube diameter 12 or 14 mm 6,000 mm for guide tube diameter 18 mm Material: Stainless steel (option: Buna (NBR), titanium) Float diameter: mm Float selection depending on guide tube diameter and process conditions (see page 17, 18, 19) T3 T4 T5 T6 180 C 130 C 95 C 80 C 60 C 60 C 60 C 60 C Alternatively normally open (NO), normally closed (NC) or change-over (SPDT) contact - on rising level 6 NO or NC, or 4 SPDT for guide tube diameter 12, 14 or 18 mm Dimensions L1, L2, L3... (from sealing face, starting from top) Minimum 20 mm (depending on the selection of the float and the contacts) Only for connection to a certified intrinsically safe circuit with ma. U i = 36 V I i = 100 ma C i = 0 nf L i = 0 μh Mounting position Vertical ±30 Ingress protection up to IP66 or IP68 per IEC/EN (depending on version) KSR data sheet LM /2017 Page 7 of 20
8 Float switch, eplosion-protected version E d, flameproof enclosure Models FLS-SAD, FLS-SBD (AL-ADF) TÜV 13 ATEX 7399 X (II 2G E d IIC T6 Gb or II 2 D E tb IIIC T80 C Db) Process connection, guide tube and float from stainless steel Mounting thread Flange 1/2" NPT 3/4" NPT M housing SW 30 or SW 36 G 1 1/2" or G 2" L 3 =... L 2 =... Float Ø Model FLS-SAD Model FLS-SBD Electrical connection housing: Aluminium Option: Stainless steel Process connection Mounting thread downwards G 1 1/2" or G 2" Mounting flange - DIN DN DN 350, PN 6... PN 40 - ANSI 2"... 14", Class Guide tube diameter 12 mm / 14 mm Guide tube length L 4,000 mm for guide tube diameter 12 mm 6,000 mm for guide tube diameter 14 mm Float Material: Stainless steel Float diameter: mm Float selection depending on guide tube diameter and process conditions (see page 17, 18, 19) Temperature range Process temperature Switching function Ma. number of contacts Switch position Distance between switch points Switching power T4 T5 T6 120 C 95 C 80 C Change-over SPDT - on rising level 4 SPDT Dimensions L1, L2, L3... (from sealing face, starting from top) Minimum 20 mm (depending on the selection of the float and the contacts) AC 230 V; 100 VA; 1.5 A With series resistance DC 230 V; 60 W; 1.5 A AC < 50 V; 40 VA; 150 ma DC < 75 V; 20 W; 150 ma With NAMUR circuit per DIN EN AC < 50 V; 40 VA; 7 ma DC < 75 V; 20 W; 7 ma Mounting position Vertical ±30 Ingress protection up to IP66 or IP68 per IEC/EN (depending on version) Page 8 of 20 KSR data sheet LM /2017
9 Float switch, miniature design Models FLS-ME, FLS-MB Process connection, guide tube 8 mm and float from stainless steel (316Ti) cable Mounting thread and connection cable Mounting thread and connection housing SW 22 or SW 27 L 3 =... L 2 =... Float Ø Electrical connection Process connection Guide tube diameter Guide tube length L Float Model FLS-ME cable PVC Silicone PUR Mounting thread upwards G 1/8" 8 mm 500 mm Model FLS-MB housing: Aluminium mm Coupler connector Mounting thread downwards G 3/4" or G 1" Material: Stainless steel (option: Buna (NBR), titanium, PP) Float diameter from mm Float selection depending on guide tube diameter and process conditions (see page 17, 18, 19) Temperature range PVC/PUR cable C Silicone cable C Observe the permissible temperature range of the float. Switching function Ma. number of contacts 3 NO or NC, or 1 SPDT Switch position Distance between switch points Switching power Normally open, normally closed Change-over Buna (NBR), PP C Stainless steel, titanium C Observe the permissible temperature range of the float. Alternatively normally open (NO), normally closed (NC) or change-over (SPDT) contact - on rising level Dimensions L1, L2, L3... (from sealing face, starting from top) Minimum 20 mm (depending on the selection of the float and the contacts) AC < 50 V; 10 VA; 0.5 A DC < 75 V; 5 W; 0.25 A AC < 50 V; 5 VA; 0.25 A DC < 75 V; 2.5 W; 0.15 A Mounting position Vertical ±30 Ingress protection up to IP66 or IP68 per IEC/EN (depending on version) KSR data sheet LM /2017 Page 9 of 20
10 Float switch, miniature design Models FLS-MA, FLS-MF Process connection, guide tube 8 mm and float from stainless steel (316Ti) cable Mounting thread and connection cable Mounting thread and connection housing SW 22 or SW % display L 3 =... L 2 =... Float Ø Electrical connection Process connection Guide tube diameter Guide tube length L Float Model FLS-MA cable PVC Silicone PUR Mounting thread upwards G 1/8" 8 mm 500 mm Model FLS-MF housing: Aluminium mm Coupler connector Mounting thread downwards G 3/4" or G 1" Material: Stainless steel (option: Buna (NBR), titanium, PP) Float diameter from mm Float selection depending on guide tube diameter and process conditions (see page 17, 18, 19) Temperature range PVC/PUR cable C Silicone cable C Observe the permissible temperature range of the float. Switching function Ma. number of contacts 3 NO or NC Switch position Distance between switch points Switching power Normally open, normally closed Alternatively normally open (NO) or normally closed (NC) - on rising level Buna (NBR), PP C Stainless steel, titanium C Observe the permissible temperature range of the float. Dimensions L1, L2, L3... (from sealing face, starting from top) Minimum 20 mm (depending on the selection of the float and the contacts) AC 230 V; 10 VA; 0.5 A DC 230 V; 5 W; 0.25 A Mounting position Vertical ±30 Ingress protection up to IP66 or IP68 per IEC/EN (depending on version) Page 10 of 20 KSR data sheet LM /2017
11 Float switch, plastic version Models FLS-PA, FLS-PF Process connection, guide tube and float from PVC, PP or PVDF cable Mounting thread and connection cable Mounting thread Flange SW 27 or SW 32 Float Ø Electrical connection Process connection Guide tube diameter Guide tube length L Float Model FLS-PF cable PVC PUR Mounting thread upwards G 3/8" Model FLS-PA housing polypropylene mm housing polyester mm Coupler connector Mounting thread downwards G 1 1/2" or G 2" Flange DIN DN DN 200, PN 6... PN 100 DIN EN DN DN 200, PN 6... PN 100 ANSI 2"... 8", Class mm / 16 mm / 20 mm 500 mm for guide tube diameter 12 mm 3,000 mm for guide tube diameter 16 mm 5,000 mm for guide tube diameter 20 mm Material: PVC, PP or PVDF Float diameter from mm Float selection depending on guide tube diameter and process conditions (see page 17, 18, 19) Temperature range For float material PVC C For float material PP C For float material PVDF C Switching function Alternatively normally open (NO), normally closed (NC) or change-over (SPDT) contact - on rising level Ma. number of contacts 6 NO or NC, or 4 SPDT Switch position Dimensions L1, L2, L3... (from sealing face, starting from top) Distance between switch points Minimum 20 mm (depending on the selection of the float and the contacts) Switching power Normally open, normally closed Change-over AC 230 V; 100 VA; 1 A DC 230 V; 50 W; 0.5 A AC 230 V; 40 VA; 1 A DC 230 V; 20 W; 0.5 A Mounting position Vertical ±30 Ingress protection up to IP66 or IP68 per IEC/EN (depending on version) KSR data sheet LM /2017 Page 11 of 20
12 Float switch, pharmaceutical version Models FLS-HA, FLS-HE Process connection, guide tube and float from stainless steel Version with cable cable SW 15 G 3/8" Impulse contact U L 2 =... L 3 =... L 2 =... U U Impulse contact Impulse contact B A Electrical connection Model FLS-HA housing: Stainless steel Model FLS-HE cable PVC Silicone PUR Process connection Mounting thread upwards G 3/8" Mounting flange per DIN or ANSI Threaded connection per DIN Clamp pipe connection per DIN Ingold sanitary fitting Guide tube diameter 17.2 mm (stainless steel or , surface ground and polished) Guide tube length L 5,000 mm Float Material: Stainless steel or Float diameter from mm Float selection depending on guide tube diameter and process conditions (see page 17, 18, 19) Temperature range PVC/PUR cable C Silicone cable C Switching function Alternatively normally open (NO), normally closed (NC) or change-over (SPDT) contact - on rising level Ma. number of contacts 6 NO or NC, or 4 SPDT 6 NO or NC, or 4 SPDT for PVC and PUR cable 3 NO or NC, or 2 SPDT for silicone cable Switch position Dimensions L1, L2, L3... (from sealing face, starting from top) Distance between switch points Minimum 20 mm (depending on the selection of the float and the contacts) Switching power Normally open, normally closed Change-over AC 230 V; 100 VA; 1 A DC 230 V; 50 W; 0.5 A AC 230 V; 40 VA; 1 A DC 230 V; 20 W; 0.5 A Mounting position Vertical ±30 Ingress protection up to IP66 or IP68 per IEC/EN (depending on version) AC < 50 V; 100 VA; 1 A DC < 50 V; 50 W; 0.5 A AC < 50 V; 40 VA; 1 A DC < 50 V; 20 W; 0.5 A Page 12 of 20 KSR data sheet LM /2017
13 Float switch, sterile version (3-A) Model FLS-HA3 Process connection, guide tube and float from stainless steel With separate float bracket With welded tube end 45 housing Ø F = L = Electrical connection Process connection Guide tube diameter Guide tube length L Model FLS-HA3 with separate float bracket housing: stainless steel Model FLS-HA3 with welded pipe connection Clamp pipe connection ISO 2852, DN 32 DN 100 or 1.5" 4" Clamp pipe connection DIN 32676, DN 32 DN 100 or 1.5" 4" Aseptic mounting thread downwards DIN , DN DN 100 or 1.5"... 4" Aseptic liner DIN , DN DN 100 or 1.5"... 4" Aseptic flange connection DIN (DN DN 50 or 1.5"... 2" Aseptic clamp connection DIN , DN DN 100 or 1.5"... 4" VARIVENT (form F,N and G) BioConnect threaded connection, DN 32 DN 100 or 1,5" 2" BioConnect flange connection, DN 32 DN 100 or 1.5" 2" BioConnect clamp connection, DN 32 DN 100 or 1.5" 4" 12 mm / 14 mm / 17.2 mm (stainless steel or , surface ground or polished, R a < 0.8 µm) 5,000 mm Float Material: Stainless steel or Float diameter: mm Float selection depending on guide tube diameter and process conditions (see page 17, 18, 19) Temperature range Process temperature Ambient temperature Switching function Ma. number of contacts Switch position Distance between switch points Switching power Normally open, normally closed Change-over C C Alternatively normally open (NO), normally closed (NC) or change-over (SPDT) contact - on rising level 3 NO or NC, or 3 SPDT Dimensions L1, L2, L3... (from sealing face, starting from top) Minimum 50 mm (depending on the selection of the float and the contacts) AC 230 V; 100 VA; 1 A DC 230 V; 50 W; 0.5 A AC 230 V; 40 VA; 1 A DC 230 V; 20 W; 0.5 A Mounting position Vertical ±30 Ingress protection up to IP66 or IP68 per IEC/EN (depending on version) KSR data sheet LM /2017 Page 13 of 20
14 Options Model Angled version Adjustable guide tube ECTFE coating Special flange from polyamide or brass FLS-SE FLS-SF FLS-SA FLS-SB FLS-SBI (60) FLS-ME FLS-MF FLS-MA FLS-MB FLS-PF FLS-PA Food version Angled version, material: Metal housing housing cable W =... G 3/8" SW 22 L =... M M U B A Angled version, material: Plastic W =... W =... G 3/8" SW 22 G 3/8" L =... SW 22 SW 22 U U L =... B A B A Page 14 of 20 KSR data sheet LM /2017
15 Version with adjustable guide tube housing housing guide tube adjustable by loosening union nut cable SW 27 guide tube adjustable by loosening union nut SW 27 Version with ECTFE coating housing Special flange from polyamide or brass Coupler connector Coupler connector A KB L = L =... 5 L =... L =... L =... L =... guide tube adjustable by loosening union nut SW G 1/2" KSR data sheet LM /2017 Page 15 of 20
16 Food version for float switch Model FLS-S Process connection, guide tube and float from stainless steel Threaded pipe connection per DIN Clamp pipe connection per DIN M housing U Threaded pipe connection B A Threaded pipe connection Clamp pipe connection Electrical connection housing: Aluminium mm, with 1 contact Aluminium mm, 2 or more contacts Option: Polypropylene, polyester, stainless steel Process connection Threaded pipe connection per DIN 11851, downwards DN DN 150 Clamp pipe connection per DIN 32676, DN 25 DN 100 or 1" 4" Guide tube diameter 12 mm / 14 mm / 18 mm Guide tube length L Guide tube diameter 12 mm / 14 mm: 3,000 mm Guide tube diameter 18 mm: 6,000 mm Float Material stainless steel or , option electropolished Float diameter from mm Float selection depending on guide tube diameter and process conditions (see page 17, 18, 19) Temperature range Process temperature C Switching function Alternatively normally open (NO), normally closed (NC) or change-over (SPDT) contact - on rising level Ma. number of contacts 3 NO or NC, or 3 SPDT Switch position Dimensions L1, L2, L3... (from sealing face, starting from top) Distance between switch points Minimum 50 mm (depending on the selection of the float and the contacts) Switching power Normally open, normally closed Change-over AC 230 V; 100 VA; 1 A DC 230 V; 50 W; 0.5 A AC 230 V; 40 VA; 1 A DC 230 V; 20 W; 0.5 A Mounting position Vertical ±30 Ingress protection up to IP66 or IP68 per IEC/EN (depending on version) Page 16 of 20 KSR data sheet LM /2017
17 Spherical float Ø C D E B D = Limit density of the medium, immersed float volume 85 % Ø A E = Nominal density of the medium, immersed float volume 50 % Material Version Suits guide tube Ø in mm Stainless steel Ø A in mm B in mm Ø C in mm Ma. operating pressure in bar Ma. operating temp. in C Limit density 85 % in kg/m 3 Order no. V29A/ V52A V62A V83A V80A V98A V105A V120A Titanium T29A T52A T52A/ T62A T83A T80A T98A T105A T120A Stainless steel ECTFE coated VEC53A Depending on medium VEC63A Depending on medium VEC84A Depending on medium VEC81A Depending on medium VEC99A Depending on medium VEC106A Depending on medium VEC121A Depending on medium Note: The optimum float will be selected after a feasibility test carried out by KSR. KSR data sheet LM /2017 Page 17 of 20
18 Cylindrical float Ø C D E B D = Limit density of the medium, immersed float volume 85 % Ø A E = Nominal density of the medium, immersed float volume 50 % Material Version Suits guide Ø A B Ø C Ma. operating Ma. Limit Order tube Ø in mm in mm in mm in mm pressure in bar operating temp. in C density 85 % no. in kg/m 3 Stainless steel V27A V44A Titanium T44A Buna (NBR) B20A B23A B25A B30A B40A B40A/ B50A PVC P44A P55A P55A/ P55A/ P80A Polypropylene PP27A PP35A PP44A PP55A PP55A/ PP80A PVDF PF44A PF55A PF55A/ ,140 - PF80A Stainless steel E-CTFE coated VEC45A Depending on medium Note: The optimum float will be selected after a feasibility test carried out by KSR. Page 18 of 20 KSR data sheet LM /2017
19 Hygienic float Ø C B Ø A Material Model Version Suits guide tube Ø in mm Stainless steel V80/88/ A34/3A/35, aial V50/55/17/ A34/3A/35 V55/70/A34/ 3A/35 aial Ø A in mm B in mm Ø C in mm Ma. operating pressure in bar Ma. operating temp. in C Limit density 85 % in kg/m 3 Order no. V80A V50A , V55A Note: The optimum float will be selected after a feasibility test carried out by KSR. KSR data sheet LM /2017 Page 19 of 20
20 Contact protection measures The reed contacts should be protected against any voltage or current spikes that might occur. Depending on the different load types different protective circuits are used. Model KFD2-ER-1.6 RC element Contact protection relays Contacts Input Power supply Approval number Order no. KFD2-ER change-over AC 250 V, 2 A 2 contacts DC V KFD2-SR2-E2.W 2 change-over AC 253 V, 2 A 2 contacts DC V II 1 GD EE ia IIC PTB 02 ATEX KFA6-ER change-over AC 250 V, 2 A 2 contacts AC 230 V KFA6-SR2-E2.W 2 change-over AC 253 V, 2 A 2 contacts AC 230 V II 1 GD EE ia IIC PTB 02 ATEX RC element Capacitance Resistance Voltage Order no. B3/ µf 470 Ohm AC 115 V B3/ µf 1,000 Ohm AC 230 V Inductive load AC voltage Inductive load DC voltage Capacitive load S1 AC V R S1 + DC V + DC 24 V S1 R S C 1 C PLC Ordering information To order the described product the order number (if available) is sufficient. Alternatively: Model / Version / Electrical connection / Process connection / Guide tube diameter / Guide tube length L / Information about contact (switching function, number of switch points, switch position) / Process specifications (operating temperature and pressure, limit density) / Options 01/2010 KSR KUEBLER Niveau-Messtechnik AG, all rights reserved. The specifications given in this document represent the state of engineering at the time of publishing. We reserve the right to make modifications to the specifications and materials. Page 20 of 20 KSR data sheet LM / /2017 EN A division of the WIKA group KSR KUEBLER Niveau-Messtechnik AG Heinrich-Kuebler-Platz Zwingenberg/Germany Tel /87-0 Fa /87-99 info@ksr-kuebler.com
Float switch For the process industry, lateral installation with external chamber Model ELS
Level measurement Float switch For the process industry, lateral installation with external chamber Model ELS KSR data sheet LM 30.03 for further approvals see page 2 Applications Mounting on engines,
More informationMagnetic float switch For vertical installation Model FLS
Level measurement Magnetic float switch For vertical installation Model FLS WIKA data sheet LM 30.01 for further approvals see page 3 Applications Level measurement for almost all liquid media Pump and
More informationLevel sensor with reed measuring chain Model FLR, for the process industry
Level measurement Level sensor with reed measuring chain Model FLR, for the process industry WIKA data sheet LM 20.02 for further approvals see page 3 Applications Level measurement for almost all liquid
More informationLevel sensor Magnetostrictive, high-resolution measuring principle Models FFG-P, FFG-T, FFG-TP, FLM-H
Level measurement Level sensor Magnetostrictive, high-resolution measuring principle Models FFG-P, FFG-T, FFG-TP, FLM-H KSR data sheet FFG-P, FFG-T, FFG-TP, FLM-H Applications High-accuracy level measurement
More informationFloat Switches with Permanent Magnet For Vertical Installation Model RSM
Level Measurement Float Switches with Permanent Magnet For Vertical Installation Model RSM WIKA Data Sheet LM 30.01 Applications Level measurement for almost all liquid media Pump/level control and monitoring
More informationReed sensor For bypass level indicators Model BLR
Level measurement Reed sensor For bypass level indicators Model BLR WIKA data sheet LM 10.04 for further approvals see page 3 Applications Sensor for the continuous level measurement of liquids in bypass
More informationFloat Switches with Permanent Magnet For Horizontal Installation Model HIF
Level Measurement Float Switches with Permanent Magnet For Horizontal Installation Model HIF WIKA Data Sheet LM 30.02 Applications Level measurement for almost all liquid media Pump/level control Chemical
More informationLevel measurement. Applications. Special features. Description
Level measurement Optoelectronic level switch Model OLS-S, for the process industry (with Ex i approval: KSR-OPTO.21*06XX) Model OSA-S, switching amplifier (with Ex i approval: KSR-OPTO.2502.XX) KSR data
More informationFloat switch For industrial applications Model RLS-1000
Level measurement Float switch For industrial applications Model RLS-000 WIKA data sheet LM 50.0 Applications Level measurement of liquids in machine building Control and monitoring tasks for hydraulic
More informationLevel sensor Stainless steel version Model RLT-1000, for industrial applications
Level measurement Level sensor Stainless steel version Model RLT-1000, for industrial applications WIKA data sheet LM 50.02 Applications Level measurement of liquids in machine building Control and monitoring
More informationGas-actuated thermometer Stainless steel version Model 73
Temperature Gas-actuated thermometer Stainless steel version Model 73 WIKA data sheet TM 73.01 for further approvals see page 15 Applications General process instrumentation in the chemical and petrochemical
More informationLevel sensor for monitoring the level of liquid media
Level sensor MG Level sensor for monitoring the level of liquid media Characteristics Level sensor output 4 20mA or Resistance output in three-wire potentiometer circuit Temperature range: -30 C to 150
More informationLS 5000 series Vibration Level Switch for liquids
Vibration Level Switch for liquids Set-up without adjustment Integrated fault monitoring Unaffected by product variations in density, conductivity, dielectric constant or viscosity Insensitive to foam,
More informationApplication The DA03 serves as indicator of differential. Follow mounting instructions in accordance to application.
DA03 Differential Pressure Gauge / Differential Pressure Gauge and Switch Models for Assignment in Explosion-hazardous Areas per Directive 94/9/EC (ATEX) Application The DA03 serves as indicator of differential
More informationThreaded resistance thermometer Miniature design Model TR10-D
Temperature Threaded resistance thermometer Miniature design Model TR10-D WIKA data sheet TE 60.04 for further approvals see page 2 Applications Machine building, plant and vessel construction Propulsion
More informationResistance thermometer With spring-loaded tip Model TR55
Temperature Resistance thermometer With spring-loaded tip Model TR55 WIKA data sheet TE 60.55 for further approvals see page 2 Applications Bearing temperature measurement on: Pumps Gears Motors Special
More informationThreaded thermocouple Miniature design Model TC10-D
Temperature Threaded thermocouple Miniature design Model TC10-D WIKA data sheet TE 65.04 for further approvals see page 2 Applications Machine building, plant and vessel construction Propulsion technology
More information97105 Inline 3/2, 5/2 & 5/3 way spool valves electromagnetic actuated, indirectly controlled G1/4, 1/4 NPT, G1/2, 1/2 NPT
70 Inline 3/, / & /3 way spool valves electromagnetic actuated, indirectly controlled G/, / NPT, G/, / NPT Main application: single and double operated actuators TÜV-approval based on type examination
More informationBourdon tube pressure gauge with electrical output signal Stainless steel, safety version, NS 63 Model PGT23.063
Mechatronic pressure measurement Bourdon tube pressure gauge with electrical output signal Stainless steel, safety version, NS 63 Model PGT23.063 WIKA data sheet PV 12.03 for further approvals see page
More informationFOR LIQUIDS AND SOLIDS
FOR LIQUIDS AND SOLIDS LEVEL SWITCHES VIBRATING FORK LEVEL SWITCHES O U R P R O F E S S I O N NIVOSWITCH VIBRATING FORK LEVEL SWITCHES MAIN FEATURES and mini compact type Rod extension up to 3 meters (10
More informationNIVOSWITCH VIBRATING FORK LEVEL SWITCHES
For liquids and solids NIVOSWITCH VIBRATING FORK LEVEL SWITCHES OUR PROFESSION IS YOUR LEVEL LEVEL SWITCHES O U R P R O F E S S I O N I S NIVOSWITCH VIBRATING FORK LEVEL SWITCHES MAIN FEATURES and mini
More informationMiniaturised pressure sensor Model M-10, standard version Model M-11, version with flush diaphragm
Electronic pressure measurement Miniaturised pressure sensor Model M-10, standard version Model M-11, version with flush diaphragm WIKA data sheet PE 81.25 for further approvals see page 5 MicroTronic
More information97105 Inline 3/2, 5/2 & 5/3 spool valves electromagnetic actuated, indirectly controlled G 1/4, 1/4 NPT, G 1/2, 1/2 NPT
705 Inline 3/, 5/ & 5/3 spool valves electromagnetic actuated, indirectly controlled G /, / NPT, G /, / NPT For single and double operated actuators Valves for safety systems up to SIL (IEC 6508) Crossover-free
More informationCombiTemp TFRN/TFRH. Operating instructions. Temperature sensor. Operating Instructions: EN.
EN/2017-04-03 Design and specifications subject to change without notice English page 1 8 Field of application CombiTemp TFRx is a temperature sensor, based on RTD technology, which is designed and produced
More informationPneumatic Control/Feedback
897 /Feedback Type 897 can be combined with... Compact design Integrated pilot valve with manual override Internal control air routing Automatic end position adjustment With ATEX II cat. G/D and cat. D/G
More informationLMP 308. Separable Stainless Steel Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO / 0.
LMP 08 Separable Stainless Steel Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.25 % FSO / 0. % FSO Nominal pressure from 0... mh 2 O up to 0... 250 mh 2 O Output signals 2-wire:
More informationLevel gauges Series LS Level indicator, switch and transmitter for liquids
Level gauges Series LS Level indicator, switch and transmitter for liquids Simple construction Resistant under extreme temperature and pressure conditions No risk of leakage Measuring range: from 150 mm
More informationElectronic pressure switch with display Model PSD-4
Electronic pressure measurement Electronic pressure switch with display Model PSD-4 WIKA data sheet PE 81.86 Applications Machine tools Hydraulics and pneumatics Pumps and compressors Special-purpose machine
More informationAdapter system for measuring instruments with G1 hygienic connection Model process adapter
Accessories Adapter system for measuring instruments with G1 hygienic connection Model 910.61 process adapter WIKA data sheet AC 09.20 Applications Food, beverage and pharmaceutical industry Cosmetics
More informationLiquiphant T FTL20. Technical Information. Level limit switch for liquids
Technical Information Liquiphant T FTL0 Level limit switch for liquids Application The Liquiphant T FTL0 is a level limit switch for all kinds of fluids and is used in tanks, containers and pipelines.
More informationVALVES Inline 3/2-, 5/2- & 5/3 Spool valves electromagnetic actuated, indirectly controlled G 1/4, 1/4 NPT, G 1/2, 1/2 NPT
975 Inline 3/-, 5/- & 5/3 Spool valves electromagnetic actuated, indirectly controlled G /, / NPT, G /, / NPT For single and double operated actuators Closed crossover design Add-on manual override Rectified
More informationFlexBar HRT Pressure Transmitter
FlexBar HRT Pressure Transmitter 4...0 ma, -wire transmitter, HART communication Some hygienic connections conform to -A standards, FDA demands and EHEDG guidelines Configurable span, unit and damping
More informationselection of special materials is available to handle almost any fluid.
For Pressure Transmitters and Bourdon Tube Pressure Gauges Types 839 X Chemical Seals for Various Applications Advantages / Benefits Separation of medium and measuring device in difficult applications
More informationOperating and monitoring systems Panel PC SERIES 400 Device platform EAGLE PM ET-436-TX
Panel PC for panel- mounting, quad core ATOM E3845 15" display, 1024 x 768 pixels with resistive foil touch screen 8 function keys Zone 1, 2, 21, 22 und Division 2, can be installed in hazardous areas
More informationOPTISWITCH 6600 C Technical Datasheet
Technical Datasheet Microwave Level Switch for standard hygienic applications Optimised sensor geometry, easy to clean Measures products with dielectric constant > 1.5 Small and compact KROHNE CONTENTS
More informationSensor boxes SRBC. Festo core product range Covers 80% of your automation tasks
Sensor boxes SRBC q/w Worldwide: Superb: Easy: Festo core product range Covers 80% of your automation tasks Always in stock Festo quality at an attractive price Reduces procurement and storing complexity
More informationFlexBar 3501 Pressure Transmitter
FlexBar 350 Pressure Transmitter 4...0 ma, -wire transmitter, HART communication (Optional) Stainless steel heavy duty housing with LC-Display (Optional) Configurable span, unit, damping and linearisation
More informationCapacitance level switches LS 210 LS 220
KROHNE 03/2001 7.02374.31.00 GR/PRINTO Capacitance level switches Compact switches for liquids, solids, slurry, foam and interface; outstanding performance for a low price Easy to install, no moving parts,
More informationVariable Area Flowmeter DATASHEET
Variable Area Flowmeter DATASHEET JUNHO 0 Data sheet DS/A6/6EN Rev. I Models A600 & A600 Purgemaster SNAP-IN Small Flowmeter Long-term reliable performance flowmeters with low cost-of-ownership High strength
More informationOperating Instructions for Level Switch for Liquids. Model: RFS
Operating Instructions for Level Switch for Liquids Model: RFS 1. Contents 1. Contents... 2 2. Note... 3 3. Instrument Inspection... 3 4. Regulation Use... 3 5. Operating Principle... 4 6. Use in Hazardous
More informationThreaded resistance thermometer With protection tube Model TR10-C
Temperature Threaded resistance thermometer With protection tube Model TR10-C WIKA data sheet TE 60.03 for further approvals see page 2 Applications Machine building, plant and vessel construction Energy
More informationLS 6600 Technical Datasheet
Technical Datasheet Switch for level detection and dry-run protection Optimised sensor geometry, easy to clean Measures products with dielectric constant > 1.5 Small and compact KROHNE 06/2011-4001367301
More informationGeneral Specifications
General Specifications Model RAGH Rotameter This type of Rotameter is designed for measurement of liquids and gases. The conical glass metering tube has a free rotating float. The mounting position is
More informationOperating and monitoring systems Panel PC SERIES 400 Device platform EAGLE PM MT-436-TX
Panel PC for panel- mounting, quad core ATOM E3845 15" display, 1024 x 768 pixels with resistive foil touch screen 8 function keys Zone 2, 22 und Division 2, can be installed in hazardous areas without
More informationPneumatic Control/Feedback
897 /Feedback Type 897 can be combined with... Compact design Integrated pilot valve with manual override Internal control air routing Bright LED position indicator Automatic end position adjustment Type
More informationLevel instruments. Point level measurement - Capacitance switches. Pointek CLS200 5/15. Overview. Configuration
Level instruments Overview Configuration is a versatile inverse frequency shift capacitance level slurries, foam and interfaces. The digital version (with PROFIBUS PA) includes a display and provides additional
More informationFlow Measurement SITRANS F M
low sensor MAG P Overview Mode of operation The flow measuring principle is based on araday s law of electromagnetic induction according to which the sensor converts the flow into an electrical voltage
More informationTechnical features. 12/ f. N/en
/, / & / way spool valves electromagnetic actuated, indirectly controlled G /, / NPT, G /, / NPT or flanged with NAMUR interface Main application: single and double operated actuators TÜV-approval based
More informationResistance thermometer For additional thermowell Model TR10-B
Temperature Resistance thermometer For additional thermowell Model TR10-B WIKA data sheet TE 60.02 for further approvals see page 2 Applications Machine building, plant and vessel construction Energy and
More informationInductive sensor NI3-EG08K-Y1-H1341
ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Threaded barrel, M8 x 1 Stainless steel, 1.4427 SO DC 2-wire, nom. 8.2 VDC Output acc. to DIN EN 60947-5-6 (NA- MUR)
More informationMaterial pressure (bar) (Cv (US) kv x 1,2 Seat
00 / poppet valves electromagnetic actuated, directly controlled G /, / NPT or flanged with NAMUR Interface TÜV-approval based on IEC 6 08, DIN V Valves for safety systems up to SIL Solenoid valve also
More informationPneumatic Control/Feedback
897 /Feedback Type 897 can be combined with... Compact design Integrated pilot valve with manual override Internal control air routing Bright LED position indicator Automatic end position adjustment Type
More information1003-h MAGNETIC FLOAT SWITCHES HORIZONTAL
1003h MAGNETIC FLOAT SWITCHES HORIZONTAL Magnetic Float Switches Horizontal / Content Table of content 1003 h Magnetic Float Switches Horizontal / Content... 116 Magnetic Float Switches Horizontal / Functional
More informationOperating pressure (bar) kv factor (m 3 /h) *3)
/ way poppet valves (stainless steel) electromagnetic actuated, directly controlled G /8, G /4 or /4 NPT Working from 0 bar up Assembled free of oil and grease Suited for fine vacuum down to,33 0 - mbar
More informationTechnical features. N/en
/, 5/ & 5/ spool valves electromagnetic actuated, indirectly controlled G /, / NPT, G /, / NPT or flanged with NAMUR interface For single and double operated actuators Exhaust air recirculation at way
More informationThreaded resistance thermometer Model TR10-C, with protection tube
Electrical temperature measurement Threaded resistance thermometer Model TR10-C, with protection tube WIKA data sheet TE 60.03 for further approvals see page 2 Applications Machine building, plant and
More information97105 NAMUR, 3/2, 5/2 & 5/3 Indirect electromagnetic actuated spool valves
970 NAMUR, /, / & / > > Port size: / or / ISO G/NPT > > Main application: single and double operated actuators > > TÜV-approval based on type examination DIN EN, DIN 9 and IEC 08 > > Valves for safety
More informationLevel Transmitter. Table of dimensions see page 4. Total length B Installation length A SW55 Ø 55 Ø 75
Level Transmitter Construction The GEMÜ level transmitter has an immersion tube with reed contacts and a chain of resistors which are triggered by a float with an integrated permanent magnet. A threaded
More informationA TECHNOLOGY FOR EVERY LEVEL APPLICATION
INSTRUCTION MANUAL A TECHNOLOGY FOR EVERY LEVEL APPLICATION NIVOSWITCH R0/R500 VIBRATION FORK LEVEL SWITCHES Dual purpose level switch with intelligent electronics applicable for: almost all liquids light,
More informationContinuous level measuring system NB 3000 Selection list
Table of contents Page Overview 2 ------------------------------------------------------------------------------------------------------------------- Specifications 3 -------------------------------------------------------------------------------------------------------------------
More informationGeneral Specifications
General Specifications Model RAGH Rotameter 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com This type of Rotameter is designed
More informationElectronic pressure switch with display For sanitary applications Model PSA-31
Electronic pressure measurement Electronic pressure switch with display For sanitary applications Model PSA-31 WIKA data sheet PE 81.85 for further approvals see page 8 Applications Food and beverage industry
More informationHERION SERIES Indirect solenoid actuated spool valves
HERION SERIES Indirect solenoid actuated spool valves for single and double acting actuators with NAMUR interface /2, /2, /, NC/APB, G/, G/2 Valves for safety systems up to SIL (IEC 08) Crossover-free
More informationInductive sensor BI1.5-EG08-Y1-H1341
ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1
More information3/2 Directional control valves Direct solenoid operated poppet valves Internal thread G 1/2, 1/2 NPT or flanged with NAMUR interface
9805 / Directional control valves Direct solenoid operated poppet valves Internal thread G /, / NPT or flanged with NAMUR interface Main application: single operated actuators for plants TÜV-approval based
More information97105 NAMUR. Technical data. Ordering information and accessories See page 6 and 7
90 NAMUR /, / and / directional valves Actuation: electromagnetic Indirectly controlled soft seal spool valves Port size: G /, / NPT, G /, / NPT NAMUR-interface For single and double operated actuators
More informationPrecision digital pressure gauge Model CPG1500
Calibration technology Precision digital pressure gauge Model CPG1500 WIKA data sheet CT 10.51 for further approvals see page 4 Applications Oil and gas industry Maintenance and service facilities Calibration
More informationThermocouples Model TC200, for Additional Thermowell
Electrical Temperature Measurement Thermocouples Model TC200, for Additional Thermowell WIKA Data Sheet TE 65.10 Applications T Machinery, plant and tank construction T Energy and power plant technology
More informationBayonet resistance thermometer Model TR53
Temperature Bayonet resistance thermometer Model TR53 WIKA data sheet TE 60.53 for further approvals see page 2 Applications Plastics processing machinery Injection moulding machinery Cylinder heads and
More informationVibration. Level detection
Vibration Level detection 5 Overview Page 116 VEGASWING 51 Page 120 VEGASWING series 60 Page 122 VEGAVIB series 60 Page 128 VEGAWAVE series 60 Page 134 Accessory Page 140 Level switches VEGATOR Page 144
More information80265 series, 3/2 Indirect solenoid actuated poppet valve
> > Port size: G/... G > > High flow rate > > Optionally air pilot operated > > High repeatability of switching time > > Variable valve solenoid combination Technical features Medium: Compressed air, filtered,
More informationFlow Measurement SITRANS F M. Transmitter MAG 6000 I/6000 I Ex de. 3/46 Siemens FI
Overview The MAG 6000 I/6000 I Ex de is a microprocessorbased transmitter with a buildin alphanumeric display in several languages. The transmitters evaluate the signals from the associated electromagnetic
More informationFlow Measurement SITRANS F M
Overview Mode of operation The flow measuring principle is based on araday s law of electromagnetic induction according to which the sensor converts the flow into an electrical voltage proportional to
More informationOperating and monitoring systems Operator Interface SERIES 300 Device platform EAGLE PM MT-336-FX
Operator Interface for panel mounting 15" display, 1024 x 768 pixels with resistive foil touch screen 8 function keys Zone 2, 22 und Division 2, can be installed in hazardous areas without additional enclosure
More informationTerminal Boxes Series 8118
> Enclosure made of glass fibre reinforced polyester resin > sizes available > Terminals and cable glands fitted to order > Enclosure design with integrated metal bracket for metal cable glands. > Degree
More informationLevel limit switch Series RF 3000 Selection list. Overview 2
Table of content Overview 2 Page Applications 4 ------------------------------------------------------------------------------------------------------------- RF 3100 6 Standard version -------------------------------------------------------------------------------------------------------------
More informationAssembly. 1 Compact version with valve plug 2 Short tube version with cable 3 Compact version with M12 plug 4 Short tube version with M12 plug
Vibration Limit Switch Features Limit switch for liquids External function test with test magnet Onsite function check possible thanks to LED indication Large selection of process connections for hassle-free
More informationExCos-P Pressure sensor 20 Pa Pa
ExCos-P Pressure sensor 20 Pa... 7.500 Pa Electrical, explosion-proof pressure / differential pressure sensors 24 VAC/DC supply voltage, 0...10 V / (0) analogue output EC type-approved in acc. with ATEX
More informationElectronic pressure switch with display For sanitary applications Model PSA-31
Electronic pressure measurement Electronic pressure switch with display For sanitary applications Model PSA-31 WIKA data sheet PE 81.85 Applications Food and beverage industry Pharmaceutical industry Filling
More informationLevel measurement CleverLevel LBFI Point level detection
User Product benefits highlights Safe detection of liquids, bulk solids and powders Short immersion length Capable of differentiation between foam and liquid Insensitive to adherent or sticky media Status
More informationEasy Flow Indicator Magnetisch-Induktiver Durchflussmesser. Type 8024 For Insertion Fittings. Analog Flow Rate Indicator, 1/2"-16"; P=87 PSI
Analog Flow Rate Indicator, 1/2"-16"; P=87 PSI Advantages / Benefits Reduced costs of ownership up to 6% Economic integration in pipe systems without any additional piping Shows flow rate with a clear,
More information97100 NAMUR series, 3/2 & 5/2 Indirect solenoid actuated spool valve
9700 NAMUR series, / & / > > Port size: /4 (ISO G or NPT), NAMUR Interface > > Crossover-free switching > > Main application: Single and double acting actuators > > / way valve usable as / way valve >
More informationInductive sensor with analog output BI15-M30-LI-EXI
ATEX category II 1 G, Ex-zone 0 ATEX category II 2 D, Ex-zone 21 Threaded barrel, M30 x 1.5 Chrome-plated brass Analog+ Extended operating range 2-wire, 14 30 VDC Analog output 4 20 ma Cable connection
More informationProduct information Ultrasonic
Product information Ultrasonic Level measurement in liquids and bulk solids VEGASON 6 VEGASON 6 VEGASON 6 Document ID: 90 Contents Contents Measuring principle... Type overview... 4 Instrument selection...
More informationInductive sensor BI1.5-EG08-Y1-H1341
ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1
More informationOperating pressure (bar)
/ poppet valves electromagnetic actuated, directly controlled G /4, /4 NPT, G /, / NPT or flanged with NAMUR Interface Main application: single operated actuators for plants Valves for safety systems up
More informationDigital Output Module 4-Channel Version for Zone 1 Series 9475/
www.stahl.de > 4-channel digital output > Intrinsically safe outputs Ex ib > Suitable for Ex i hydraulic valves and solenoid valves > Additional Ex i control input for (in accordance with IEC 61508 through
More informationSideControl Positioner
SideControl Positioner Electropneumatic positioner for pneumatically actuated process valves II (1) 2 G EEx ia IIC T6 approval can be combined with... Type 2712 Globe valve Globe valve acc. to NAMUR/IEC
More informationMANUAL Surge Protectors
PROCESS AUTOMATION MANUAL Surge Protectors DP-LBF-I1.36.DE and DP-LBF- I1.36.IE With regard to the supply of products, the current issue of the following document is applicable: The General Terms of Delivery
More informationIndicating Digital Transmitter for Differential Pressure and Flow. Media 6 with LCD Media 6 with LED
Indicating Digital Transmitter for Differential Pressure and Flow Media 6 with LCD Media 6 with LED Application Microprocessor-controlled transmitter for measuring and indicating the differential pressure
More informationSeries 3730 Type Electropneumatic Positioner
Series 3730 Type 3730- Electropneumatic Positioner Application Single-acting or double-acting positioner for attachment to pneumatic control valves. Self-calibrating, automatic adaptation to valve and
More informationElectronic pressure switch with display For sanitary applications Model PSA-31
Electronic pressure measurement Electronic pressure switch with display For sanitary applications Model PSA-31 WIKA data sheet PE 81.85 Applications Food and beverage industry Pharmaceutical industry Filling
More informationElectronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm
Pressure Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm WIKA data sheet PE 81.67 Applications Machine tools Hydraulics and pneumatics Pumps and
More informationLevel Measurement Continuous level measurement - Ultrasonic transmitters
Overview Configuration is a short-range integrated ultrasonic level transmitter. It is intrinsically safe (ATEX, CSA, FM, IECEx, NEPSI), 2 wire, to 20 ma loop powered, ideal for liquids, slurries, and
More informationOperating pressure. N/en/en
660, 8007 NAMUR /, / & / spool valves electromagnetic actuated, indirectly controlled G / and NAMUR interface For single and double operated actuators Manual override with and without detent Simple design
More informationOperating and monitoring systems Thin Client SERIES 500 Device platform EAGLE PM ET-556-TX
Thin Client for panel mounting, 19" display, 1280 x 1024 pixels Zone 1, 2, 21, 22, can be installed in hazardous areas without additional enclosure All-round degree of protection, resistive foil touch
More informationDMP 333 DMP 333. Industrial Pressure Transmitter For High Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial
DMP Industrial Pressure Transmitter For High Pressure Stainless Steel Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 / 0. % FSO Industrial Pressure Transmitter DMP Nominal pressure
More informationMaterial Seat seal. N/en
0 / poppet valves electromagnetic actuated, directly controlled G /, / NPT or flanged with NAMUR interface TÜV-approval based on IEC 6 8 Valves for safety systems up to SIL Standard NAMUR type - redundancy:
More informationInductive sensor BI5-EM18-Y1X-H1141
ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1
More informationWHG. RoHS Z Z Compliant
'18 High- Lights WHG Z-65.40-753 Z-65.13-572 RoHS 2 For all transactions, the newest version of the General Conditions of Sale and Delivery for Products and Services of the Electrical Industry ZVEI shall
More information