2 Transforming ustomer Needs into ustomer Solutions At arling Technologies, we do much more than manufacture electrical components. We engineer powerful solutions. Working closely with your product team, we can tailor switching and circuit protection solutions that meet your application needs cost effectively. Since our founding in 90, there are few products we haven t turned on, fewer industries that haven t turned to us. With five ISO certified manufacturing locations and technical sales offices worldwide, arling Technologies now ranks among the world s largest privately owned manufacturers of hydraulic/magnetic circuit breakers, thermal circuit protectors, electrical switches and assemblies, power distribution centers and electronic control systems. In regard to circuit protection, we lead the industry in delivering higher ratings in smaller packages. And what makes all our breakers especially attractive is their superior performance and reliability both hallmarks of arling Technologies. We have over 000 employees working through offices and manufacturing sites across the globe, providing engineered solutions to leading electronic and industrial OEMs in a variety of industries, including: Electronics (telecom, medical, computers, office automation) Transportation (on/off road vehicles, trucks, buses, boats) Industrial ontrols Appliances Factory Automation We look forward to helping you create safe, reliable products that exceed the tough demands of today s applications. You ll find our commitment to excellence consistently delivers Quality by Design, our company s mission. Our commitment to quality products begins with our investment in research and development. Not only does arling have a team of highly-qualified engineers on staff, we equip them with the industry s most advanced computer-aided design tools. Our engineering team will work closely with yours to advance your project from initial product concepts to final design and manufacturing. Using industry-leading AD/AM software, arling engineers can evaluate multiple design alternatives as well as develop products, tooling and manufacturing processes concurrently. The result? Functionally superior, aesthetically pleasing products produced faster and at a lower cost. We can even share electronic files that can be easily incorporated into the rest of your design. Just one more reason you ll think of arling as much more than an approved vendor, but rather as a proven partner. Our automated call center system ensures that your calls are routed to the right ustomer are person for prompt attention. Our customer care personnel are technically trained to discuss your requirements and provide the advice and services you expect from arling Technologies. Each member of the arling ustomer are team is technically trained on our standard products, and Application Engineers are also available to answer your more advanced technical questions. In addition, arling is proud to offer a global network of fully trained representatives and distributors, who are always ready to service you.

3 Other arling Technologies atalogs ircuit Protection This -page catalog details arling s comprehensive line of hydraulic/magnetic and equipment leakage circuit breakers from. to 700 amps, for most any circuit protection, power switching and circuit control need. Worldwide Agency Approvals, E Marked. Power Distribution enters This catalog includes the complete line of standard A and D Power Distribution enters and Battery Disconnects. All products are designed to fit into industry standard racks, from RU to RU, and utilize arling hydraulic/magnetic circuit breakers. Switches and ontrols This catalog includes the complete line of arlingswitch brand electrical switches for most any power switching need. Included are rocker, toggle, pushbutton, rotary and sealed switches with a wide variety of circuits, ratings, terminations, colors, illuminations, and legends. Worldwide certifications, UL500, E marking available. Electronic ontrol Systems This catalog details arling s Electronic ontrol System III, (ES III). The ES III features the latest in digital multiplex technology, creating a safer and fully configurable control system for the marine environment. The ES III eliminates complex wiring while increasing switching features and functionality, and simplifies troubleshooting.

4 ircuit Breaker Selector Guide Hydraulic / Magnetic M-Series A-Series B-Series -Series Number of Poles - -6 (handle); - (rocker) -6-6 (handle); - (rocker) Available Delays Instant, Short Medium & High Inrush A/D Instantaneous, Ultra-short, Short, Medium & Long, A, D, A/D High Inrush - Short, Medium & Long A and D Instantaneous, Ultra-short, Short, Medium & Long, A, D, A/D High Inrush - Short, Medium & Long A and D Instantaneous, Ultra-short, Short, Medium & Long, A, D, A/D High Inrush - Short, Medium & Long A and D Maximum urrent & Voltage Ratings 0.0-5FLA, VD, 5 VA, -pole; 5.-0GPA, VD, 5VA, -pole; 0.0-5FLA, 65VD, 50VA, -pole; 5.-0GPA, 65VD, 50VA,-pole; 0.0-FLA, 50VA, -pole; GPA, 50VD, -pole 0.0-0A 80VD Polarity Sensitive ( pole) 0.0-0A@77VA, 80VD.0-50A@5/50VA, 65VD 0.0-0A@77VA, 80VD.0-50A@5/50VA, 65VD UL Listed A@80VD A@5VD A@0VA 0.0-0A@0VA UL Recognized 0.0-0A@80WYE /77VA -pole, Ø, -pole, Ø A@77VA A@50VA, 80VD A@0/0VA, 65VD Maximum Interrupting apacity 65 VD, -pole VD, -pole 50VA, -pole 5VA, -pole 65VD, -pole (polarity sensitive) 600A@80VD -pole (polarity sensitive) 65 VD, UL only 65 VD, w/fuse backup 5/50VA, UL only 77VA, w/fuse backup 65 VD, UL only 65 VD, w/fuse backup 5/50VA, UL only 77VA, w/fuse backup UL Listed 50000A@80VD, 0,000A@0VA, 5000A@5VD, 0VA UL Recognized 7500A@80VD 000A@5/50VA, UL only 50VA 5000A@80WYE/77VA w/fuse backup Auxilary Switch Ratings 7A@ 50VA 0.A@5VA (gold contacts) 7A(res.)@8VD A(Ind.)@8VD 0.A@5VA 0.A@5VA (gold contacts) 0.5A@65VD 0.A@80VD 0.A@5VA 0.A@5VA (gold contacts) 0.5A@65VD 0.A@80VD 0.A@50VA 0.A@5VA (gold contacts) 0.5A@65VD 0.A@80VD Available ircuits Series, Switch Only Series, Shunt, Relay, Switch Only, Series w/remote Shutdown, Relay & Shunt Trip Dual oil Series, Shunt, Relay, Switch Only, Series w/remote Shutdown, Relay & Shunt Trip Dual oil, Mid-Trip with Alarm Switch Series, Shunt, Relay, Switch Only, Series w/remote Shutdown, Relay & Shunt Trip Dual oil, Mid-Trip with Alarm Switch Terminal Options.50 Tab w/ Q, 8- Screw.50 Tab w/ Q, 8- & 0- Screw (& metric), PB.50 Tab w/ Q, 8- & 0- Screw (& metric), PB 0- Stud, /-0 Stud, 0- Screw w/ saddle clamp, lip Terminal, / & 7/6 Push-In Mounting Method Agency Approvals Dimensions Rocker: Front Panel Snap-In Handle: Threaded Bushing, Push-Pull UL, SA, VDE(rocker), UL89A Threaded inserts: Front Panel Snap-In UL, SA, VDE, TUV(rocker), UL500, UL89A Threaded inserts: Front Panel Snap-In UL, SA, VDE, TUV(rocker), UL500, UL89A Threaded inserts UL, SA, VDE, TUV, UL500, UL89, UL89A

5 ircuit Breaker Selector Guide Hydraulic / Magnetic Earth Leakage D-Series E-Series F-Series PD-Series Number of Poles - (handle); - (rocker) Available Delays Instantaneous, Ultra-short, Short, Medium & Long, A, D, A/D High Inrush - Short, Medium & Long A and D Instant, Short, Medium & Long - A, D, and A/D High Inrush - Short, Medium & Long- A, D, and A/D Short, Medium & Long D Short, Medium & Long A Maximum urrent & Voltage Ratings A@77VA, 65VD 0.0-0A@80WYE /77VA, pole, Ø, pole Ø UL Listed A@0VA, 65VD, 5VD UL Recognized A@77VA, 60VD, -pole A@600VA, -pole Ø, pole Ø 0.0-0A@5VD, -pole UL89 Listed: 50-50A@5VD UL89A Listed A@5VD -50A@0/08, 0/0 Ø, 08-0 Ø -50A@80VA Ø (WYE connected) Leakage urrent 7-00mA Maximum Interrupting apacity 500A without fuse, 5000A with 65 VD, 50VA, VDE only 65 VD 80WYE/77VA, w/fuse backup,ul only 5/50VA, UL only UL Listed 5000A@65VD 5000A@5VD & 0VA UL Recognized 5VD 600VA, without fuse backup 600VA, w/fuse backup 50000A@5VD 5000A@08VA 000A@80VA (WYE connected) Auxilary Switch Ratings n/a 0.A@ 50VA.0A@65VD 0.A@80VD 0.A@ 50VA 0.5A@65VD 0.A@80VD n/a Available ircuits Series, Switch Only, Series w/remote Shutdown Series, Shunt, Relay, Switch Only, Series w/remote Shutdown Series & Switch Only with or without Metering Shunt Series Trip with leakage urrent Protection Terminal Options Recessed Wire-ready, Pressure Plate Type Screw Terminals 0- Stud, /-0 Stud 0- Screw, /-0 Screw Box Wire onnector /8-6 Stud, /8-6 Screw & Box Wire onnector Box Wire onnector Mounting Method Rear Mounted on DIN Rail or Front Panel Rear or Front Panel Rear or Front Panel DIN Rail or Front Panel Agency Approvals UL, SA, VDE UL, SA, VDE, UL500, UL89 Dimensions.7 UL,TUV, UL89, UL89A UL, SA,TUV

6 Introduction Introduction Any electrical or electronic equipment that is designed without including circuit protection is an accident waiting to happen. Under normal operating conditions, this may not appear to be a problem. However, normal operating conditions are not always guaranteed. Under strained or heavy use, a motor and/or another load-generating component within the equipment will draw additional current from the power source; when this happens, the equipment s wires and/or components will overheat and may ultimately burn up. Also, power surges and short circuits in unprotected equipment can cause extensive damage to the equipment and to the conductors leading to the equipment. In addition to protecting the equipment, the entire electrical system including the control switches, wires, and power source must be protected from faults. A circuit protection device should be employed at any point where a conductor size changes. Many electronic circuits and components like transformers have a lower overload withstand threshold level than conductors such as wires and cables. These components require circuit protection devices featuring very fast overload sensing and opening capabilities. Specifying a circuit protection device for an application is not a difficult task, but it will require some thought. If electrical and electronic equipment is designed with over-specified circuit protection devices they will be vulnerable to the damaging effects of power surges and the catastrophic results of a fire; while using under-specified circuit protection devices will result in nuisance tripping. Before specifying a circuit protection device, equipment designers should evaluate the load characteristics during equipment startup and at normal operation. Many types of equipment will produce startup inrush current, or surges. In these cases, circuit breakers with the appropriate time delay should be selected. The time delay specified should slightly exceed the duration of the surge. Before specifying a circuit protection device, an equipment designer should also consider the following: Applied voltage rating (A or D) Single phase, multi-phase / number of poles Applicable national electric codes and safety regulatory agency standards Interrupting (short circuit) capacity Mounting requirements and position / enclosure size constraints The short circuit capacity of a circuit protection device should be greater than the circuit s available short circuit fault current. Available short circuit current is the maximum RMS current that would be present if all the conductors were to be connected directly to the fault location. In reality, this is not the case. The actual short circuit current is much less than the available short circuit current. The actual short circuit current is reduced due to the combined impedance of the conductors, the size of the transformer and other current restricting components within the circuit. The application s environmental conditions must be considered when selecting the proper circuit protection device. Excessive temperature, humidity, severe vibration and shock can cause adverse performance characteristics in many types of circuit protection devices. For instance, a fuse element is less reliable when it is hot than when it is cold. The mounting position of a hydraulic/magnetic circuit breaker is critical to its performance. A standard hydraulic/magnetic circuit breaker should be mounted on a vertical panel as gravity will influence the "must hold" and "must trip" calibration. It is possible to specify the breaker for use in other mounting positions, however, special factory calibration will be required to prevent adverse performance characteristics.

7 Regulatory Agencies Regulatory Agencies Most countries have regulatory agencies that determine the safety and performance standards required for products used in that country. arling Technologies' circuit breakers are tested and have been certified by the most widely recognized of these agencies, including Underwriters Laboratories (UL) in the United States; anadian Standards Association (SA) in anada; TUV Rheinland/Berlin-Brandenburg (TUV) and Verband Deutscher Elektrotechniker (VDE) in Germany. UL Recognized/UL077 Recognized UL Recognition covers components, which are incomplete or restricted in performance capabilities. These components will later be used in complete end products or systems Listed by UL. These Recognized components are not intended for separate installation in the field, they are intended for use as components of complete equipment submitted for investigation to UL. arling Technologies offers circuit breakers which are classified as supplementary circuit protectors and are Recognized under the UL omponents Recognition Program as Protectors, Supplementary, UL Standard 077. A UL 077 Recognized supplementary circuit protector must have a Listed overcurrent device as a "back up". arling's M, A, B,, D and E circuit breakers offer UL 077 Recognition. UL Listed/UL 89 Listed UL Listing indicates that samples of the circuit breaker as a complete product have been tested by UL to nationally recognized safety standards and have been found to be free from reasonably foreseeable risks of fire, electric shock and related hazards, and that the product was manufactured under UL's Follow-Up Services program. arling Technologies offers branch circuit breakers that are UL 89 Listed. Branch circuit breakers are classified as a final overcurrent device dedicated to protecting the branch circuit and outlet(s). They do not require an additional "back up" overcurrent device wired in series to protect a circuit. arling's, E and F-Series circuit breakers offer UL89 Listing. In addition, they are UL89A Listed for Telecom industry. UL500 (MARINE) UL500 refers to products and components classified as ignitionprotected, and are intended to be installed and used in accordance with applicable requirements to the U.S. oast Guard, the Fire Protection Standard for Pleasure and ommercial Motor raft, ANSI/NFPA No. 0, and the American Boat and Yacht ouncil, Incorporated. Specially constructed versions of arling Technologies' A, B and -Series circuit breakers meet this standard. SA The SA (anadian Standards Association) is the closest in concept and nature to UL of any group outside of the United States. Their standards and requirements are often almost identical to corresponding UL standards. SA publishes their standards for most circuit protection devices as separate sections of SA Standard. that in turn, forms a part of the anadian Electrical ode. All of arling Technologies circuit protection products meet the applicable requirements of SA Standard.. UL A cul mark on a product means that samples of the product have been evaluated to the applicable anadian standards and codes by Underwriters Laboratories Inc. VDE and TUV There are two German government approved independent agencies, VDE (Verband Deutscher Elektrotecchniker), and TUV (Technisher Uberwachungs-Verein). In the circuit protection field, outside of the U.S.A. and anada, VDE is the best known certification mark. VDE testing facilities are located in Germany. TUV also performs testing and grants certification in accordance to the IE/EN specifications. TUV's organization is made up of at least eleven geographically dispersed companies. At least two are located in the United States. This aids some U.S. manufacturers in getting "fast track" approval to a IE/EN specifications. arling's M, A, B,, D and E-Series breakers have been certified to meet EN 609 by VDE and TUV labs. E MARKING The European Union's (EU) approach to create single market access is based on four principles: harmonized directives, harmonized standards, harmonized conformity assessment procedures and E marking. The E marking is affixed to products indicating that the product conforms to relevant directives and standards. Various directives and standards contain the requirements for E marking. The E marking is primarily for market control by custom inspectors. Before a manufacturer can affix the E marking to their product they must complete the following steps:. Identify the applicable EU directive/standard. Perform the conformity assessment according to the applicable EU directive/standard. Establish a Technical File containing test reports, documentation, certificates, etc.. Prepare and sign a EU Declaration of onformity Many of arling Technologies circuit protection products are available with E marking indicating conformance to Low Voltage Directive 7//EE. 5

8 Introduction Available hoices of ircuit Protection arling Technologies offers three types of circuit protection devices: thermal circuit protectors, hydraulic/magnetic circuit protectors/breakers and equipment leakage circuit breakers. This catalog features hydraulic/magnetic circuit protection and equipment leakage circuit breaker products. For details related to our thermal circuit protection product line, please see our thermal circuit protection catalog. Thermal circuit protectors utilize a bimetallic strip electrically in series with the circuit. The heat generated by the current during an overload deforms the bimetallic strip and trips the breaker. Thermal protectors have a significant advantage over fuses in that they can be reset after tripping. They can also be used as the main ON/ switch for the equipment being protected. However, thermal breakers have some disadvantages. They are, in effect, "heat sensing" devices, and can be adversely affected by changes in ambient temperature. When operating in a cold environment, they will trip at a higher current level. When operating in a hot environment, they will "nuisance trip" at a lower current level resulting in unwanted equipment shut downs. Hydraulic/magnetic circuit protectors/breakers provide highly precise, reliable and cost effective solutions to most design problems. They have the advantages of thermal breakers but none of their disadvantages. The hydraulic/magnetic circuit breaker is considered to be temperature stable and thus is not appreciably affected by changes in ambient temperature. It s over-current sensing mechanism reacts only to changes of current in the circuit being protected. It has no "warm-up" period to slow down its response to overload. It has no "cool-down" period after overload before it can be reset. The characteristics of a hydraulic/magnetic circuit breaker can be tailored in four separate areas: the desired circuit; the trip point (in amperes); the time delay (in seconds); and the inrush handling capacity of the breaker. These factors can be varied with relatively little impact on the short circuit capability of the breaker. Typically, hydraulic/magnetic circuit breakers are available with a choice of three different trip time, delay curves: slow, medium and long. These choices provide the designer with a high level of design flexibility when matching the breakers trip time delay curves to other circuit protection devices in a cascade, or discriminating circuit. In addition, special hi-inrush constructions are available for equipment with severe inrush characteristics. Equipment leakage circuit breakers function as hydraulic/magnetic circuit breakers, offering customized overload and short circuit protection. In addition, they sense and guard against faults to ground using innovative electronics technologies. With the exception of small amounts of leakage, the current returning to the power supply will be equal to the current leaving the power supply. If the difference between the current leaving and returning through the earth leakage circuit breaker exceeds the leakage sensitivity setting, the breaker trips and it s LED illuminates. The LED gives a clear indication that the trip occurred as a result of leakage to ground. This protection helps prevent serious equipment damage and fire. arling Technologies Hydraulic/Magnetic ircuit Breakers arling Technologies hydraulic/magnetic circuit breakers are current sensing devices employing a time proven hydraulic magnetic design. Their precision mechanisms are temperature stable and are not adversely affected by temperature changes in their operating environment. As such, derating considerations due to temperature variations are not normally required, and heat-induced nuisance tripping is avoided. Features A trip-free mechanism, a safety feature, makes it impossible to manually hold the contacts closed during overcurrent or fault conditions. Worldwide safety agency approvals are available. urrent ratings to 700 Amps and rated voltages to 600 VA are available. A common trip linkage between all poles, another safety feature, ensures that an overload in one pole will trip all adjacent poles. Series trip, mid-trip and switch only (with or without auxiliary switch), remote shutdown, shunt trip, relay trip and dual coil circuit options are offered. Handle actuators, solid color rocker actuators, illuminated rocker actuators and the exclusive Visi-Rocker two-color rocker actuators, allow design flexibility and contemporary panel styling. 5mm DIN Rail back panel mounting available for world market applications. Industry standard dimensions, mounting and current ratings provide maximum application versatility. 6

9 Applications / What Makes a Magnetic ircuit Breaker Trip Typical Applications Magnetic circuit breakers protect wiring, motors, generators, transformers, solid state systems, computers, telecommunications systems, micro-processors, peripheral and printing devices, office machines, machine tools, medical and dental equipment, instrumentation, vending machines, industrial automation and packaging systems, process control systems, lamps, ballasts, storage batteries, linear and switching power supplies, as well as marine control panels and numerous other applications. Generally, wherever precise and reliable circuit protection is required, a magnetic circuit breaker is specified. What Makes a Magnetic ircuit Breaker Trip The most common magnetic circuit breaker configuration is called Series Trip. It consists of a current sensing coil connected in series with a set of contacts. (Fig. ) Line Terminal ontacts (Open) Figure Sensing oil Load Terminal Inside the coil is a non-magnetic delay tube, housing a springbiased, moving, magnetic core. An armature links the contacts to the coil mechanism, which functions as an electro magnet. When the contacts are open, there is no current flow through the circuit breaker, and no electro-magnetic energy is developed by the coil. When the contacts are closed, current flow begins. (Fig. ) toward the pole piece. As the core moves inward, the efficiency of the magnetic circuit is increased, creating an even greater electro-magnetic force. When the core is fully in, maximum electro-magnetic force is attained, the armature is attracted to the pole piece, unlatching a trip mechanism, thereby opening the contacts. (Fig. ) Armature Electro-magnetic Force Pole Piece Spring (compressed) Sensing oil Load Line ontacts Terminal Terminal (Open) Moving Magnetic ore Delay Tube ("in"position) Electro-magnetic Force Figure - Moderate Overload with Induced Delay Under short circuit conditions, the resultant increase in electromagnetic energy is so rapid, that the armature is attracted without core movement, allowing the breaker to trip without an induced delay. This is called instantaneous trip. It is a safety feature which results in a very fast trip response when most needed. (Fig. ) Line Terminal Armature ontacts (losed) Delay Tube Spring (extended) Sensing oil Load Terminal Moving Magnetic ore ("out"position) Armature Electro-magnetic Force Pole Piece Spring (compressed) Sensing oil Load Line ontacts Terminal Terminal (Open) Moving Magnetic ore Delay Tube ("out"position) Electro-magnetic Force Figure - Rated urrent or Less As the normal operating or rated current flows through the sensing coil, a magnetic field is created around that coil. When the current flow increases, the strength of the magnetic field increases, drawing the spring-biased, movable, magnetic core Figure - Short ircuit ondition - No Induced Delay 7

10 How Time Delays are Obtained / Available ircuit Options How Various Time Delays are Obtained Generally speaking, the trip time of a time delay magnetic circuit breaker is directly related to the length of time it takes for the moving metal core to move to the fully in position. If the delay tube is filled with air, the core will move rather quickly, and the breaker will trip quickly. This is characteristic of the Ultrashort Delay urves # and #. Solid state devices, which cannot tolerate even short periods of current overload, should use Instantaneous urves #0, #0 and #0. These curves have no intentional time delay. When the delay tube is filled with a light viscosity (temperature stable) fluid, the core s travel to the full in position will be intentionally delayed. This results in the slightly longer Medium Pole Piece Spring (partially compressed) Delays #,, and, which are used for general purpose applications. When a heavy viscosity fluid is used, the result will be a very long delay, such as Delay urve #6, #6, #6 or #6. These curves are commonly used in motor applications to minimize the potential for nuisance tripping during lengthy motor start-ups. By use of magnetic shunt plates within the magnetic circuit, it is possible to divert magnetic flux resulting in higher inrush withstanding capability (or high inrush delays). These delays disregard short duration, high pulse surges (typically 8ms or less and up to 5x rated current), characteristic of transformers, switching power supplies and capacitive loads. Delay urves #, #, and #6, are available for these applications. to contacts Temperature Stable Fluid (with a special viscosity for each delay) Sensing oil Delay Tube Load Terminal Hydraulic delay protectors have the added advantage of tripping slightly sooner when operating in higher temperature conditions and slightly longer when cold. This characteristic mirrors the protection needs in most applications. Note that the current required to trip the breaker does not change, just the time delay for tripping. Moving Magnetic ore Available ircuit Options Rated urrent or Less Series Trip A basic two terminal device is usually used as a combination power switch and overload protector. The contacts and current sensing coil are connected in series with the line and load terminals. Series Trip with Auxiliary Switch Same as a Series Trip except with the addition of a S.P.D.T. snap-action switch, which is electrically isolated, but mechanically linked to the movement of the main breaker contacts. This switch is commonly used to remotely signal the status of the breaker (ON or /TRIPPED). ontacts (Open) urrent Sensing oil ontacts (Open) urrent Sensing oil Line Terminal Load Terminal Line Terminal Load Terminal losed Normally Open Auxiliary Switch Normally losed 8

11 Available ircuit Options Available ircuit Options Series Mid-Trip with Auxiliary/Alarm Switch Similar to Series Trip with Auxiliary Switch except the S.P.D.T. auxiliary switch is actuated only upon electrical trip of the breaker. Upon electrical trip, the N.O. contact closes and the N.. contact opens. This can be used to remotely signal the TRIPPED status of the breaker. Also, upon electrical trip, the handle moves to the MID position as opposed to the full position typical of other breakers. This gives a specific visual panel indication of a TRIPPED breaker as compared to one which is merely turned. Series Mid-Trip is also available without Auxiliary/Alarm Switch. Line Terminal losed ontacts (Open) Normally Open Auxiliary Switch Normally losed Series Trip with Remote Shutdown urrent Sensing oil Load Terminal (For dump circuit or panic circuit applications). Same as a Series Trip but with an additional (self-interrupting) voltage coil pole (usually of opposite polarity) for remote shutdown. In the example, a momentary voltage pulse to Pole will shut down both Pole and Pole. Because the voltage coil in Pole is self-interrupting, no additional components, such as auxiliary switches, etc., are required in that circuit. Approximately watts minimum is required to activate the voltage coil pole. This extra pole configuration is usually required by World Approval Agencies. onsult factory for this circuit. Dual oil with Remote Shutdown Similar to Series Trip with Remote Shutdown except an extra pole is T required. A Dual oil breaker has two coils in the space normally occupied by a single coil. A current coil is used for overload protection and the instant trip voltage coil can be used for remote shutdown. Approximately 0 watts minimum is required to activate this type of voltage coil. Two Dual oil options are available. The most common is the Relay Trip Dual oil, a four terminal device in which the voltage coil circuit is electrically isolated from the current coil circuit. This allows the triggering of the voltage coil from an independent voltage source separate from line voltage. As such, a D pulse to the voltage coil can be used to shutdown a primary high energy A circuit. However, because voltage coils are rated for intermittent duty, provisions must be made to disconnect the power source from the voltage coil after tripping. Line Terminal ontacts urrent Sensing oil Voltage oil Load Terminal (primary circuit) Secondary "shutdown" or "dump" circuit The other circuit option is the Shunt Trip Dual oil, a three terminal device with one side of the voltage coil internally connected to the primary circuit. The other side of the voltage coil is connected to an external third terminal on the bottom of the breaker. This circuit option uses line voltage for dual coil activation, saving wiring costs and resulting in a self-protecting voltage coil. POLE POLE Line Terminal Line Terminal ontacts urrent Sensing oil Load Terminal Load ontacts Terminal Voltage oil (intermittent duty) Line Terminal ontacts urrent Sensing oil Voltage oil Secondary "shutdown" or "dump" circuit utilizing Primary ircuit Voltage Load Terminal (primary circuit) are must be taken to avoid mis-wiring of the primary and secondary (voltage coil) circuits. Mis-wiring could lead to damage to the voltage coil and/or its power source. 9

12 Available ircuit Options Available ircuit Options Switch Only Same as a Series Trip, but without a sensing coil. Provides low cost, heavy-duty switch capability when overload protection is not needed. Switch Only is available with and without an auxiliary switch. ontacts Shunt Trip A three terminal device similar to Series Trip, but with the addition of a third terminal between the contacts and the coil. This circuit is usually used to control two separate loads (A&B) from the same power source, while sensing overload current in only one load (B). It should be noted that overload protection is not provided in the load (A) circuit, and if needed, must be provided by other means. Also, the sum of the current in circuit A & B must not exceed the contact rating of the device. Line Terminal Load Terminal ontacts urrent Sensing oil Relay Trip A four terminal device in which the contact and coil circuits are electrically isolated but mechanically linked. An overload in the coil circuit will cause the contact circuit to open. These circuits may be of opposite polarity. ommonly used in dump circuit, panic circuit, and remote shutdown applications. (Note: World Approval Agencies may require a more electrically isolated voltage coil pole for this function - Ref. Series Trip with Remote Shutdown circuit option.) ontacts (unprotected) urrent Sensing or Voltage oils Line Terminal Load "A" Terminal (unprotected) Load "B" Terminal (protected) Another application possibility occurs when a voltage coil (rated for line voltage) is used. Here the load (B) terminal is connected in series with a N.O. push-button switch or similar control device. With this, a line voltage pulse through the coil can be used as a means of remotely opening the load (A) circuit. Because the voltage coil is self-interrupting, no additional components, such as auxiliary switches, etc., are needed in the load (B) circuit. ontacts Line Voltage oil Intermittent Duty Line Terminal Load Terminal RelayTerminals. Voltage coils rated for intermittent duty only, and must be disconnected after being pulsed. Line Terminal Load "A" Terminal (unprotected) Load "B" Terminal (protected) 0

13 M-Series Time Delay Values M-SERIES TIME DELAY VALUES PERENT OF RATED URRENT Delay 00% 5% 50% 00% 00% 600% 800% 000% 00% TRIP 0, 0, 0 No Trip May Trip.00 Max.00 Max.00 Max.00 Max.00 Max.00 Max.00 Max TIME,,, 6, 7, 9 No Trip SEONDS,,, 6, 7, 9 No Trip TES: Delay urves,,,,,, 6, 6, 7, 7, 9, 9: Breakers to hold 00% and must trip at 5% of rated current and greater within the time limit shown in this curve. Delay urves 0, 0, 0: Breakers to hold 00% and must trip at 50% of rated current and greater within the time limit shown in this curve. All urves: urve data shown represents breaker response at ambient temperature of 77 F (5 ) with no preloading. Breakers are mounted in standard wall-mount position. The minimum inrush pulse tolerance handling capability is times the rated current on standard delays and 8 times the rated current on high inrush delays. These values are based on a 60 Hz / cycle, 8. ms pulse. High inrush delays should be specified for applications with high initial surge currents of short duration, such as switching power supplies, highly capacitive loads and transformer loads. Dual Rated A/D Instantaneous 0000 INSTANTANEOUS URVE S. 0, 0 AND TRIP TIME IN SEONDS Short 50 PERENT OF RATED URRENT 0000 SHORT DELAY URVE S.,,, 6, 7 AND TRIP TIME IN SEONDS Medium 50 PERENT OF RATED URRENT 0000 MEDIUM DELAY URVE S.,,, 6, 7 & TRIP TIME IN SEONDS PERENT OF RATED URRENT

14 A-D and PD-Series Time Delay Values A, B,, D & PD-SERIES TIME DELAY VALUES PERENT OF RATED URRENT DELAY 00% 5% 5% 50% 00% 00% 600% 800% 000% 00% 0 No Trip May Trip MAX.0 MAX.00 MAX.08 MAX.06 MAX.05 MAX.0 MAX No Trip No Trip No Trip No Trip No Trip May Trip MAX.05 MAX.00 MAX.05 MAX.00 MAX.07 MAX.05 MAX No Trip TRIP No Trip TIME No Trip (SEONDS) 6 No Trip No Trip May Trip No Trip May Trip No Trip May Trip No Trip No Trip No Trip No Trip No Trip No Trip TES: PD-Series offered with A urves Only. UL89 -Series Breakers available with Delay urves,,, 6,,,, 6,,, 6. Delay urves,,,6,,,,6,,,6,5,5,56: Breakers to hold 00% and must trip at 5% of rated current and greater within the time limit shown in this curve. Delay urves,,6: Breakers to hold 00% and must trip at 5% of rated current and greater within the time limit shown in this curve. Delay urves 0,0: Breakers to hold 00% and must trip at 50% of rated current and greater within the time limit shown in this curve. All urves: urve data shown represents breaker response at ambient temperature of 77 F (5 ) with no preloading. Breakers are mounted in standard wall-mount position. On 50 amp and less current ratings, the minimum inrush pulse tolerance handling capability is times the rated current on standard delays and 5 times the rated current on high inrush delays. These values are based on a 60 Hz / cycle, 8. ms pulse. High inrush delays should be specified for applications with high initial surge currents of short duration such as switching power supplies, highly capacitive loads and transformer loads. Instantaneous A 50/60 Hz INSTANTANEOUS URVE D (A-D-Series Only) D.. INSTANTANEOUS URVE. 0 TRIP TIME IN SEONDS TRIP TIME IN SEONDS Ultrashort PERENT OF RATED URRENT /60 Hz ULTRASHORT DELAY URVE PERENT OF RATED URRENT D.. ULTRASHORT DELAY URVE. TRIP TIME IN SEONDS TRIP TIME IN SEONDS Short PERENT OF RATED URRENT 50/60 Hz SHORT DELAY URVE PERENT OF RATED URRENT 50 D.. SHORT DELAY URVE. TRIP TIME IN SEONDS TRIP TIME IN SEONDS PERENT OF RATED URRENT PERENT OF RATED URRENT 50

15 A-D and PD-Series Time Delay Values Medium A 50/60 Hz MEDIUM DELAY URVE D (A-D-Series Only) D.. MEDIUM DELAY URVE. TRIP TIME IN SEONDS TRIP TIME IN SEONDS Long PERENT OF RATED URRENT 50 50/60 Hz LONG DELAY URVE PERENT OF RATED URRENT 50 D.. LONG DELAY URVE. 6 TRIP TIME IN SEONDS TRIP TIME IN SEONDS PERENT OF RATED URRENT PERENT OF RATED URRENT High Inrush A High Inrush D (A-D-Series Only) Short /60 Hz - HI-INRUSH SHORT DELAY URVE D.. - HI - INRUSH SHORT DELAY URVE. 5 TRIP TIME IN SEONDS TRIP TIME IN SEONDS Medium PERENT OF RATED URRENT 50/60 Hz - HI-INRUSH MEDIUM DELAY URVE PERENT OF RATED URRENT D.. - HI - INRUSH MEDIUM DELAY URVE TRIP TIME IN SEONDS 0. TRIP TIME IN SEONDS Long PERENT OF RATED URRENT 50/60 Hz - HI-INRUSH LONG DELAY URVE PERENT OF RATED URRENT D.. - HI - INRUSH LONG DELAY URVE. 56 TRIP TIME IN SEONDS TRIP TIME IN SEONDS PERENT OF RATED URRENT 5 50 PERENT OF RATED URRENT

16 A-D-Series Time Delay Values A/D (A-D Series Only) Short D.., 50/60 Hz SHORT DELAY URVE. TRIP TIME IN SEONDS Medium PERENT OF RATED URRENT D.., 50/60 Hz MEDIUM DELAY URVE. TRIP TIME IN SEONDS Long 5 50 PERENT OF RATED URRENT D.., 50/60 Hz LONG DELAY URVE TRIP TIME IN SEONDS PERENT OF RATED URRENT

17 E-Series Time Delay Values E-SERIES TIME DELAY VALUES PERENT OF RATED URRENT Delay 00% 5% 5% 50% 00% 00% 600% 800% 000% 00% 0 No Trip May Trip , 7 No Trip , 7 No Trip TRIP 6, 76 No Trip TIME 0 No Trip May Trip (SEONDS), 6 No Trip , 6 No Trip , 66 No Trip No Trip May Trip , 9 No Trip May Trip , 9 No Trip May Trip , 96 No Trip May Trip TES Delay urves 0,0,0: Breakers to hold 00% and must trip at 50% of rated current and greater wthin the time limit shown in these curves. Delay urves,,6,,,6,6,6,66,7,7,76: Breakers to hold 00% and must trip at 5% of rated current and greater wthin the time limit shown in these curves. Delay urves,,6,9,9,96: Breakers to hold 00% and must trip at 5% of rated current and greater wthin the time limit shown in these curves. All curves: Data shown represents breaker response at ambient temperature of 77 F (5 ) with no preloading: Breakers are mounted in standard wall-mount position. The minimum inrush pulse tolerance handling capacity on the above standard delays is 6 times rated current & 0 times rated current for high inrush delays based on a 60Hz / cycle, 8. ms pulse. A D Instantaneous /60 Hz INSTANTANEOUS URVE D.. INSTANTANEOUS URVE TRIP TIME IN SEONDS TRIP TIME IN SEONDS PERENT OF RATED URRENT 50 PERENT OF RATED URRENT Short /60 Hz SHORT DELAY URVE. HI INRUSH URVE D.. SHORT DELAY URVE. HI-INRUSH URVE TRIP TIME IN SEONDS 0. TRIP TIME IN SEONDS PERENT OF RATED URRENT 50 PERENT OF RATED URRENT Medium /60 Hz MEDIUM DELAY URVE. HI INRUSH URVE D.. MEDIUM DELAY URVE. HI INRUSH URVE TRIP TIME IN SEONDS 0. TRIP TIME IN SEONDS PERENT OF RATED URRENT 50 PERENT OF RATED URRENT Long /60 Hz LONG DELAY URVE. 6 HI INRUSH URVE D.. LONG DELAY URVE. 6 HI INRUSH URVE. 76 TRIP TIME IN SEONDS TRIP TIME IN SEONDS PERENT OF RATED URRENT PERENT OF RATED URRENT

18 E-Series Time Delay Values A/D Instantaneous D /60 Hz INSTANTANEOUS DELAY URVE TRIP TIME IN SEONDS Short 50 PERENT OF RATED URRENT D /60 Hz SHORT DELAY URVE. HI INRUSH URVE TRIP TIME IN SEONDS 0..0 Medium PERENT OF RATED URRENT D /60 Hz MEDIUM DELAY URVE. HI INRUSH URVE TRIP TIME IN SEONDS Long 50 PERENT OF RATED URRENT D /60 Hz LONG DELAY URVE. 6 HI INRUSH URVE TRIP TIME IN SEONDS PERENT OF RATED URRENT 6

19 F-Series Time Delay Values F-SERIES TIME DELAY VALUES PERENT OF RATED URRENT Delay 00% 5% 50% 00% 00% 600% 800% 000% TRIP No Trip TIME No Trip SEONDS No Trip No Trip TES: UL89 F-Series Breakers available with Delay urves,,, 6. Delay urves,,,6: Breakers to hold 00% and must trip at 5% of rated current and greater within the time limit shown in this curve. All urves: urve data shown represents breaker response at ambient temperature of 77 F (5 ) with no preloading. Breakers are mounted in standard wall-mount position. The minimum inrush pulse tolerance handling capabilities is 0 times rated current based on a 60 Hz / cycle, 8. ms pulse. Ultrashort D 0000 D.. ULTRASHORT DELAY URVE TRIP TIME IN SEONDS Short 50 PERENT OF RATED URRENT 0000 D.. SHORT DELAY URVE TRIP TIME IN SEONDS Medium 50 PERENT OF RATED URRENT 0000 D.. MEDIUM DELAY URVE TRIP TIME IN SEONDS PERENT OF RATED URRENT Long 0000 D.. LONG DELAY URVE TRIP TIME IN SEONDS PERENT OF RATED URRENT 7

20 M-Series General Specifications The low cost M-Series utilizes the hydraulic magnetic principle which provides accurate and reliable circuit protection even when exposed to extremely hot and/or cold application environments. Available in a choice of rocker actuator styles and colors, push button, push-pull, paddle, and baton style handle actuators, the Visi-Rocker two-color actuators as well as non-illuminated or illuminated rocker versions with LED or neon bulbs. The exclusive Rockerguard bezel helps prevent inadvertent actuation. "Wiping" contact design insures long term reliability. Various styling options allow design flexibility. Typical applications would include power supplies, medical equipment, and telecommunications equipment. Agency ertifications UL Recognized UL Standard 077 omponent Recognition Program as Protectors, Supplementary (N/Guide QVNU, File E75596) SA ertified omponent Supplementary Protector under lass 5 0, FIle SA Standard. No. 5 UL Listed UL Standard 89A ircuit Breakers, ommunications Equipment (N/Guide DITT, File E8995) VDE ertified TUV ertified EN609, VDE 06 under File No. 057 EN609 under License No. E Electrical Table A: Lists UL Recognized & SA ertified configurations & performance capabilities as a omponent Supplementary Protector. M-SERIES TABLE A: OMPONENT SUPPLEMENTARY PROTETOR VOLTAGE URRENT RATING INTERRUPTING APAITY (AMPS) FULL GENERAL UL / SA IRUIT MAX PURPOSE POLES WITH WITHOUT ONFIGURATION RATING FREQUENY PHASE AMPS AMPS BREAKING BAKUP FUSE BAKUP FUSE D D D , D SERIES 80 D / / / / Notes for Tables A : Requires Branch ircuit backup with a UL Listed type K-5 or Type RK-5 Fuse rated 60 Amps maximum. Polarity Sensitive. Available only with special catalog number. onsult factory. 8

21 M-Series General Specifications Electrical Table B: Lists UL Recognized and SA, VDE & TUV ertified configurations & performance capabilities as a omponent Supplementary Protector. M-SERIES TABLE B: OMPONENT SUPPLEMENTARY PROTETOR VOLTAGE URRENT RATING INTERRUPTING APAITY (AMPS) FULL GENERAL UL / SA VDE / TUV IRUIT MAX PURPOSE POLES WITH WITHOUT WITH WITHOUT ONFIGURATION RATING FREQUENY PHASE AMPS AMPS BREAKING BAKUP FUSE BAKUP FUSE BAKUP FUSE BAKUP FUSE D D D SERIES 80 D / / / Notes for Table B: Requires Branch ircuit backup with a UL Listed type K-5 or Type RK-5 Fuse rated 60 Amps maximum. Requires backup protection with a thermal magnetic circuit breaker rated 6 Amps and having a Type trip characteristic per EN60898/DINVDE 06 (6A). Polarity Sensitive. Available only with special catalog number. onsult factory. 5 TUV only. Table : Lists UL89A Listed & TUV ertified configurations & performance capabilities for use in ommunications Equipment. M-SERIES TABLE : UL89A (OMMUNIATIONS EQUIPMENT -- POLARITY SENSITIVE) VOLTAGE URRENT RATING GENERAL INTERRUPTING APAITY (AMPS) WITHOUT IRUIT MAX PURPOSE POLES BAKUP FUSE ONFIGURATION RATING FREQUENY AMPS BREAKING UL89A TUV 80 D SERIES 65 D D Notes for Table : Available only with Special atalog Number. 9

22 M-Series General Specifications Electrical Mechanical Maximum Voltage 5/50 VA 50/60 Hz, 80 VD (See Rating Tables.) urrent Ratings Standard current coils: 0.00, 0.50, 0.500, 0.750,.00 thru 5.0 in amp increments, 8.0, 0.0, 5.0, 0.0. Other ratings available - see Ordering Scheme. Auxiliary Switch Rating SPDT; 7A 50VA, 7A (Res) 8VD, A (Ind.) 8VD, 0.5A 80VD (Res) (silver contacts), 0.A 5VA (gold contacts). Insulation Resistance Minimum of 00 Megohms at 500 VD. Dielectric Strength UL, SA 500V, 50/60 Hz for one minute between all electrically isolated terminals. M-Series ircuit Breakers comply with the 8mm spacing and 750 V 50/60Hz dielectric requirements from hazardous voltage to operator accessible surfaces, per Publications IE 80, 5, 950, EN and VDE Resistance, Impedance Values from Line to Load Terminal - based on Series Trip ircuit Breaker. RESISTANE, IMPEDANE VALUES from Line to Load Terminals (Values Based on Series Trip ircuit Breaker) O H M S AMPERE RATING Pulse Tolerance urves Multiple of Rated urrent 8x x I r 60 Hz / ycle Inrush Pulse Tolerance Time Delay urves 6, 6, 9 & 9 Time Delay urves,, & t 6.67 Time in Milliseconds Multiple of Rated urrent 6x 0x I r URRENT (AMPS) Hz / ycle Inrush Pulse Tolerance TOLERANE (%) ± 5% ± 5% Time Delay urves 6, 6, 9 & 9 Time Delay urves,, & 0.0 Time in Milliseconds t Endurance Trip Free Trip Indication Physical 0,000 ON- 6 per minute with rated urrent and Voltage. All M-Series ircuit Breakers will trip on overload, even when actuator is forcibly held in the ON position. The actuator moves positively to the position when an overload causes the circuit breaker to trip. Number of Poles or Internal ircuit onfigurations Series with or without Auxiliary Switch. Switch Only with or without Auxiliary Switch. Weight Approximately 0 grams/pole (Approximately.07 ounces/pole) Standard olors See Ordering Scheme. Environmental Designed and tested in accordance with requirements of specification MIL-PRF-5569 & MIL-STD-0 as follows: Shock Withstands 00 Gs, 6ms, sawtooth while carrying rated current per Method, ond. I. Instantaneous curves tested at 80% of rated current. Vibration Withstands 0.060" excursion from 0-55 Hz, and 0 Gs Hz, at rated current per Method 0, Test ondition A. Instantaneous curves tested at 80% of rated current. Moisture Resistance Method 06D, i.e., ten -hour + 5 to +65, 80-98% RH. Salt Spray Method 0, ondition A (90-95% 5% Nal Solution, 96 hrs). Thermal Shock Method 07D, ondition A (Five -55 to +5 to +85 to +5 ). Operating Temperature -0 to +85 hemical Resistance Only the outside surfaces of the case and the handles may be cleaned with detergents or alcohol. Organic (hydrocarbon based) solvents are not recommended because they attack plastics. aution should be taken when solvents are used to clean and remove flux from terminals. Lubricants should not be introduced into the handle/bushing openings. 0

23 M-Series Handle/Push Button UL Recognized Ordering Scheme M Series M B 60 B B Actuator Poles ircuit 5 Frequency & Delay 6 urrent Rating 7 Terminal 8 Actuator olor 9 0 Front Panel Legend Hardware Plate B Bushing olor Agency Approval SERIES M ATUATOR Handle M Paddle N Baton AP Push Button ATUATOR T Push-Pull U Push To Reset Push Button w/ Snap-In Mounting V Push-Pull W Push To Reset POLES One Two 6 URRENT RATING (AMPERES) IRUIT without Auxiliary Switch A Switch Only (No oil), Maintained ontacts B Series Trip (urrent) with Auxiliary Switch, Silver ontacts Terminal Type: P Switch Only, Maintained ontacts.060 Dia, Round Solder Turret Q, Switch Only, Maintained ontacts.058 Dia, Round Q.. S Series Trip (urrent).060 Dia, Round Solder Turret T, Series Trip (urrent).058 Dia, Round Q.. with Auxiliary Switch, Gold ontacts, Switch Only, Maintained ontacts.058 Dia, Round Q.. Series Trip (urrent).058 Dia, Round Solder Turret 7 TERMINAL 8 Push-On 0.50 Tab (Q..) 0 Screw 8- w/upturned lugs 0 Screw 8- (Bus Type) 8 ATUATOR OLOR 5 Handle Push-Button Actuator olor A White B Black Red D Green 5 E Blue 6 F Yellow 8 H Orange 0 Screw 8- (Back-connected) A Push-In Stud 5 FREQUENY & DELAY 0 D 50/60Hz, Switch Only 0 D Instantaneous D Short D Medium 0 50/60Hz Instantaneous 50/60Hz Short 50/60Hz Medium 0 D, 50/60Hz Instantaneous D, 50/60Hz Short D, 50/60Hz Medium 6 50/60Hz Short, Hi-Inrush 6 50/60Hz Medium, Hi-Inrush 7 D, Short,Hi-Inrush 7 D, Medium, Hi-Inrush 9 D, 50/60Hz Short, Hi-Inrush 9 D, 50/60Hz, Medium, Hi-Inrush 9 FRONT PANEL HARDWARE 6 Handle Push-Button No outer Panel Hardware A Knurled Nut Bright nickel B Bright nickel w/ locking ring Black D Black w/ locking ring E Panel Dress Nut Bright nickel F Bright nickel w/ locking ring G Black H Black w/ locking ring J One actuator is located in the center of each multi-pole breaker. Switch Only circuits are not available with Push-To-Reset actuators. For Switch Only circuits, select urrent oil Rating from the following chart: VOLTAGE MAX. RATING FREQUENY PHASE FULL AMP RATING MAX. AMPS HOOSE URRENT OIL RATING ODE: GENERAL PURPOSE AMP RATING MAX. AMPS HOOSE URRENT OIL RATING ODE: 65 onsult Factory 65 TUNGSTEN LAMP RATING One Auxiliary Switch is supplied per breaker. On two-pole breakers, standard Auxiliary Switch mounting is in pole one. Auxiliary Switch option limited to Series Trip and Switch Only circuits. Not available with back connect screw or push-in stud terminals. Mates with AMP.058" diameter pin receptacles including (gold plated) and (tin plated). 5 Actuator color is only visible in the position on Push-Pull actuators. 6 All units have one hex nut installed on bushing for use behind the panel. 7 Other colors available. onsult factory. 8 TUV and VDE ertification above 5 amps is for -pole only and is limited to a max. of 5 amps. Screw Terminal or Push-In Stud recommended above 0 amps. 9 0 amp rating not available with delay s 0,,, 9 or 9. 0 Screw Terminals are VDE certified only with use of ring terminal attached to wire. MAX. AMPS HOOSE URRENT OIL RATING ODE: POLES BREAKING D D D /60HZ /60HZ /60HZ LEGEND PLATE / BUTTON MARKING Handle Actuator Legend Plate (Actuator Styles M & N) A No Legend Plate B ON - Vertical ON - Horizontal D I - O Vertical E I - O Horizontal Push-Pull Actuator Button ap (Actuator Styles T & V) No Marking Rated Amps Horizontal Rated Amps Line Side Down Rated Amps Line Side Up Push-to-Reset Actuator Button (Actuator Styles U& V) No Marking BUSHING OLOR 7 B Black AGENY APPROVAL 8 UL Recognized & SAertified D VDE ertified, UL Recognized & SAertified E TUV ertified, UL Recognized & SAertified

24 M-Series Handle/Push Button UL89A/UL Recognized Ordering Scheme M Series M B 60 B B Actuator Poles ircuit 5 Frequency & Delay 6 urrent Rating 7 Terminal 8 Actuator olor 9 Front Panel Hardware 0 Legend Plate B Bushing olor J Agency Approval SERIES M ATUATOR 7 TERMINAL Push-On 0.50 Tab (Q..) Screw 8- w/upturned lugs Screw 8- (Bus Type) Screw 8- (Back-connected) A Push-In Stud Handle M Paddle N Baton Push Button T Push-Pull Push Button w/ Snap-In Mounting V Push-Pull POLES One IRUIT without Auxiliary Switch B Series Trip (urrent) with Auxiliary Switch, Silver ontacts Terminal Type: S Series Trip (urrent).060 Dia, Round Solder Turret T, Series Trip (urrent).058 Dia, Round Q.. with Auxiliary Switch, Gold ontacts Series Trip (urrent).058 Dia, Round Solder Turret 5 FREQUENY & DELAY D Short D Medium AP ATUATOR 6 URRENT RATING (AMPERES) D, Short,Hi-Inrush 7 D,Medium, Hi-Inrush ATUATOR OLOR & LEGEND 5 Gloss Handle Push-Button Actuator olor A White B Black Red D Green 5 E Blue 6 F Yellow 8 H Orange 9 FRONT PANEL HARDWARE 6 Handle Push-Button No outer Panel Hardware A Knurled Nut bright nickel B bright nickel w/ locking ring black D black w/ locking ring E Panel Dress Nut bright nickel F bright nickel w/ locking ring G black H black w/ locking ring J 0 LEGEND PLATE / BUTTON MARKING Handle Actuator Legend Plate (for Paddle and Baton Actuators) A No Legend Plate B ON - Vertical ON - Horizontal D I - O Vertical E I - O Horizontal Push-Pull Actuator Button ap 8 No Marking Rated Amps Horizontal Rated Amps Line Side Down Rated Amps Line Side Up BUSHING OLOR 7 B Black AGENY APPROVAL 9 J UL89A LISTED, TUV ERTIFIED M UL REOGNIZED N UL REOGNIZED, TUV ERTIFIED T UL89A LISTED One actuator is located in the center of each multi-pole breaker. One Auxiliary Switch is supplied per breaker. On two-pole breakers, standard Auxiliary Switch mounting is in pole one. Auxiliary Switch option limited to Series Trip and Switch Only circuits. Not available with Back onnected Screw or Push-in Stud terminals. Mates with AMP.058" diameter pin receptacles including (gold plated) and (tin plated). Screw terminals or Push-in Stud recommended above 0 amps. 5 Actuator color is only visible in the position on Push-Pull actuators. 6 All units have one hex nut installed on bushing for use behind the panel. 7 Other colors available. onsult factory. 8 Not available with UL89A Listed breakers. 9 TUV certified to 5 amps. UL Recognized, SA certified and UL Listed to 0 amps.

25 M-Series Rocker UL Recognized Ordering Scheme M Series G B 60 H 6 Actuator Poles ircuit 5 Frequency & Delay 6 urrent Rating 7 Terminal 8 Illumination 9 Actuator olor 0 Legend 7 Bezel olor Agency Approval SERIES M ATUATOR Non-Illuminated single color A Angled B Flat Two olor Visi-Rocker D Indicate ON E Indicate llluminated single color F Angled G Flat STYLE VERTIAL HORIZONTAL INDIATE - "ON" ROKER STYLE DESRIPTION (DUAL LEGEND SHOWN) INDIATE - "" FLAT ANGLED 6 URRENT RATING (AMPERES) POLES One Two 7 TERMINAL 0 Push-On 0.50 Tab (Q..) Screw 8- w/upturned lugs Screw 8- (Bus Type) Screw 8- (Back-connected) A Push-In Stud IRUIT without Auxiliary Switch A Switch Only (No oil), Maintained ontacts B Series Trip (urrent) with Auxiliary Switch, Silver ontacts Terminal Type: P Switch Only, Maintained ontacts.060 Dia, Round Solder Turret Q, Switch Only, Maintained ontacts.058 Dia, Round Q.. S Series Trip (urrent).060 Dia, Round Solder Turret T, Series Trip (urrent).058 Dia, Round Q.. with Auxiliary Switch, Gold ontacts Switch Only, Maintained ontacts.058 Dia, Round Q.., Series Trip (urrent).058 Dia, Round Solder Turret 5 FREQUENY & DELAY 0 D 50/60Hz, Switch Only 0 D Instantaneous D Short D Medium 0 50/60Hz Instantaneous 50/60Hz Short 50/60Hz Medium 0 D, 50/60Hz Instantaneous D, 50/60Hz Short D, 50/60Hz Medium 6 50/60Hz Short, Hi-Inrush 6 50/60Hz Medium, Hi-Inrush 7 D, Short,Hi-Inrush 7 D,Medium, Hi-Inrush 9 D, 50/60Hz Short, Hi-Inrush 9 D, 50/60Hz, Medium, Hi-Inrush One actuator is located in the center of each multi-pole breaker. For Switch Only circuits, select urrent oil Rating from the following chart: VOLTAGE MAX. RATING FREQUENY PHASE FULL AMP RATING MAX. AMPS HOOSE URRENT OIL RATING ODE: GENERAL PURPOSE AMP RATING MAX. AMPS HOOSE URRENT OIL RATING ODE: TUNGSTEN LAMP RATING D D onsult Factory D /60HZ /60HZ /60HZ One Auxiliary Switch is supplied per breaker. On two-pole breakers, standard Auxiliary Switch mounting is in pole one. Auxiliary Switch option limited to Series Trip & Switch Only circuits, and is not available in single pole illuminated breakers, or Back onnected Screw or Push-in Stud terminals. Mates with AMP.058" diameter pin receptacles: (gold plated) & (tin plated). 5 For neon bulb applications at 7K, / WATT and for 50VA 50K, / WATT, external resistors must be supplied by customer. 6 On Visi-Rocker breakers, Visi portion of rocker cannot be the same color as the bezel. 7 For LED (D or rectified A) applications, LED is mounted in the center of the rocker actuator with electrical characteristics as follows: 00 millicandela at 0mA; Maximum power dissipation = 75mW at 5 ; Maximum forward current = 5mA; Typical forward voltage =.V at 0mA; Typical reverse current = 00uA at V. ustomer supplies the proper external resistor limiting current to these values. 8 Rocker color for LED s and green neon lamp must be clear, smoke gray, white translucent or match color of LED or neon lamp. 9 Other colors available. onsult factory. 0 TUV and VDE ertified to 5 amps. UL Recognized and SA ertified to 0 amps. Screw Terminals or Push-in Stud recommended above 0 amps. TUV or VDE ertified must have I-O or Dual Legends. Legend required on Visi-Rocker breakers. 0 amp rating not available with delay s 0,,, 9 or 9. Screw Terminals are VDE certified only with use of ring terminal attached to wire. MAX. AMPS HOOSE URRENT OIL RATING ODE: POLES BREAKING 8 ROKER ILLUMINATION Non-illuminated A Neon 5 Neon Green Glow 8 without resistor, 0VA/50VA B LED 7, 8 Red Green Amber without resistor D G K with resistor, -8 VD E H L with resistor, 9-6 VD F J M 9 ATUATOR & LEGEND OLOR Solid olor Actuator Legend White Black Black White Red White Green White 5 Blue White 6 Yellow Black 7 Gray Black 8 Orange Black Visi-Rocker 6 Visi & Legend (remainder of rocker same color as bezel) White Black Red Green 5 Blue 6 Yellow 7 Gray 8 Orange Illuminated 8 Actuator Legend A lear Black B Red Transparent White Green Transparent White D Amber Transparent White E Smoke Gray Transparent Black F White Translucent Black 0 LEGEND No Legend ON - Vertical ON - Horizontal I - O Vertical 5 I - O Horizontal 6 Dual Vertical 7 Dual Horizontal BEZEL OLOR / STYLE 9 olor without Rockerguard with Rockerguard White A Black B Gray G 7 AGENY APPROVAL 0 UL Recognized & SAertified D VDE ertified, UL Recognized & SAertified E TUV ertified, UL Recognized & SAertified

26 arling M-Series Rocker UL89A/UL Recognized Ordering Scheme M Series A B 60 A 6 Actuator Poles ircuit 5 Frequency & Delay 6 urrent Rating 7 Terminal 8 Illumination 9 Actuator olor 0 Legend J Bezel olor Agency Approval SERIES M ATUATOR Non-Illuminated single color A Angled B Flat Two olor Visi-Rocker D Indicate ON E Indicate llluminated single color F Angled G Flat STYLE VERTIAL HORIZONTAL INDIATE - "ON" POLES One ROKER STYLE DESRIPTION (DUAL LEGEND SHOWN) INDIATE - "" FLAT ANGLED IRUIT without Auxiliary Switch B Series Trip (urrent) with Auxiliary Switch, Silver ontacts Terminal Type S Series Trip (urrent).080 x.00 Flat Q../Solder T Series Trip (urrent).058 Dia, Round Q.. with Auxiliary Switch, Gold ontacts Series Trip (urrent).058 Dia, Round Q.. 9 ATUATOR & LEGEND OLOR Solid olor Actuator Legend White Black Black White Red White Green White 5 Blue White 6 Yellow Black 7 Gray Black 8 Orange Black Visi-Rocker 6 Visi & Legend (remainder of rocker same color as bezel) White Black Red Green 5 Blue 6 Yellow 7 Gray 8 Orange Illuminated Actuator Legend A lear Black B Red Transparent White Green Transparent White D Amber Transparent White E Smoke Gray Transparent Black F White Translucent Black 0 LEGEND 0 No Legend (Single olor or Illuminated Rocker Options Only) ON - Vertical ON - Horizontal I - O Vertical 5 I - O Horizontal 6 Dual Vertical 7 Dual Horizontal 5 FREQUENY & DELAY 0 D Instantaneous D Short 6 URRENT RATING (AMPERES) TERMINAL 9 Push-On 0.50 Tab (Q..) Screw 8- w/upturned lugs Screw 8- (Bus Type) D Medium 7 D, Short,Hi-Inrush 7 D,Medium, Hi-Inrush ILLUMINATION Non-illuminated A Neon Neon Green Glow 7 without resistor, 0VA/50VA B LED Red Green Amber without resistor 5, 7 D G K with resistor, -8 VD E H L with resistor, 9-6 VD F J M Screw 8- (Back-connected) A Push-In Stud BEZEL OLOR / STYLE 8 olor without Rockerguard with Rockerguard White A Black B Gray G 7 AGENY APPROVAL 9 J UL89AListed & TUV ertified M UL Recognized & SAertified N TUV ertified, UL Recognized & SAertified T UL89A Listed One actuator is located in the center of each multi-pole breaker. One Auxiliary Switch is supplied per breaker. Auxiliary Switch option limited to Series Trip & Switch Only circuits, and is not available in single pole illuminated breakers, or with Back onnected Screw or Push-in Stud terminals. Mates with AMP.058" diameter pin receptacles: (gold plated) & (tin plated). For neon bulb applications at 7K, / WATT and for 50VA 50K, / WATT, external resistors must be supplied by customer. 5 For LED (D or rectified A) applications, LED is mounted in the center of the rocker actuator with electrical characteristics as follows: 00 millicandela at 0mA; Maximum power dissipation = 75mW at 5 ; Maximum forward current = 5mA; Typical forward voltage =.V at 0mA; Typical reverse current = 00uA at V. ustomer supplies the proper external resistor limiting current to these values. 6 On Visi-Rocker breakers, Visi portion of rocker cannot be the same color as the bezel. 7 Rocker color for LED s and green neon lamp must be clear, smoke gray, white translucent or match color of LED or neon lamp. 8 Other colors available. onsult factory. 9 TUV ertified to 5 amps. UL Recognized, SA ertified and UL89A Listed to 0 amps. Screw Terminals recommended above 0 amps. 0 UL89A Listed must have ON- or Dual legends. TUV ertified approvals must have I - O or Dual legends.

27 M-Series Handle ircuit & Terminal Diagrams TERMINAL DIMENSIONAL DETAIL SERIES TRIP TAB (Q..) TERMINAL SREW TERMINAL #8- WITH UPTURNED LUGS SREW TERMINAL #8- BUS PUSH-IN STUD TERMINAL MAIN TERM'S. (SEE TABLE A).95 [.] SWITH ONLY.50 [6.5].75 [9.5].75 [9.5].000 [5.].9 [9.97]*.70 [9.0].0 [0.].0 [0.].5 [.9].00 [.5].750 [9.05] *ENTER OF PUSH-IN STUD ONTAT AREA SERIES TRIP W/ AUXILIARY SWITH AUXILIARY SWITH TERMINALS.65 [.9].55 [.9] N AUX. SWITH TERM'S..060 DIA [Ø.5].058 DIA [Ø.7].50 [8.89] DOUBLE SOLDER TURRET TYPE ROUND QUIK-ONNET TYPE MULTI-POLE IDENTIFIATION SHEME SEE TABLE A DEPTH BEHIND PANEL FAE +.00 [+.05] [-.00].6 DIA [Ø.0] N ±.00 ±.76.5 [8.58] PUSH-IN STUD POLE POLE FIG. A.0 [.8] TYP.5 [.8] TYP MATING HOLE TABLE A TERMINAL DESRIPTION DEPTH BEHIND * PANEL FAE MAIN AUX. ** SWITH TAB (Q.) SREW (#8-)*** PUSH-IN STUD DOUBLE SOLDER TURRET TYPE ROUND Q. TYPE.890 [8.00].90 [9.0].50 [6.00].05 [5.69].05 [5.] *DEPTH INLUDES BEHIND PANEL HEX NUT AS SUPPLIED ON ALL UNITS. **WHEN ALLED FOR ON MULTI-POLE UNITS, ONLY ONE AUX. SWITH IS RMALLY SUPPLIED, MOUNTED AS SHOWN IN FIG. A ***REOMMENDED TIGHTENING TORQUE -5 IN-LBS [. -.7 NM] All dimensions are in inches [millimeters]. Tolerance ±.05 [.8] unless otherwise specified. 5

28 M-Series Handle Form & Fit Drawings PADDLE ATUATOR STYLE SINGLE POLE /- THD. ±.00 ± [5.].5 [.8] ±.00 ± [7.7] ON.75 [.9] ±.00 ±.76.5 [8.58] FLAT ±.00 ± [.70].70 [.9] ±.05 ±.8.70 [9.0] TAB (Q..) TERMINALS SHOWN. ±.00 ±.76 FOR TERMINAL DETAILS.765[.8] SEE IRUIT AND TERMINAL DIAGRAMS. DOUBLE POLE /- THD. ±.00 ± [9.].5 [.8]] ±.00 ± [.] ON.75 [.9] ±.00 ±.76.5 [8.58] FLAT ±.00 ± [.70].70 [.9] ±.00 ± [.8] ±.05 ±.8.70 [9.0].65 [5.88] BATON ATUATOR STYLE ±.00 ± [5.88].500 DIA [Ø.70] MOUNTING DETAILS DIA [Ø.70] ±.005 [±.].55 [9.0] DIA [Ø.8] ±.00 [±.050]. [5.6].80 DIA [Ø.57] WITH LOKING RING WITHOUT LOKING RING LEGEND PLATES.05 [.6].0 [8.6].6 DIA [Ø6.05] 0N.05 [6.0] O N O F F 0FF LEGEND ODE: B D E PANEL HARDWARE.65 [5.88].5 [.8].680 DIA [Ø7.7].80 [.57].680 DIA [Ø7.7].5 [.8].05 [.67]. [8.69].68 DIA [Ø7.7].0 [.79] HEX NUT PANEL DRESS NUT KNURLED NUT LOKING RING TES:. TOLERANES ±.00 [.5] UNLESS OTHERWISE SPEIFIED.. ALL DIMENSIONS SHOWN ARE IN INHES [mm] All dimensions are in inches [millimeters]. Tolerance ±.00 [.5] unless otherwise specified. 6

29 SERIES TRIP M-Series Pushbutton ircuit & Terminal Diagrams TERMINAL DIMENSIONAL DETAIL MAIN TERM'S. (SEE TABLE A) TAB (Q..) TERMINAL SREW TERMINAL #8- WITH UPTURNED LUGS SREW TERMINAL #8- BUS PUSH-IN STUD TERMINAL.95 [.] SWITH ONLY (PUSH-PULL ONLY).50 [6.5].75 [9.5].75 [9.5].000 [5.].9 [9.97]*.70 [9.0].0 [0.].0 [0.].00 [.5].750 [9.05].5 [.9] SERIES TRIP W/ AUXILIARY SWITH.65 [.9] AUXILIARY SWITH TERMINALS.55 [.9] *ENTER OF PUSH-IN STUD ONTAT AREA N.060 DIA [Ø.5].058 DIA [Ø.7].50 [8.89] AUX. SWITH TERM'S. DOUBLE SOLDER TURRET TYPE ROUND QUIK-ONNET TYPE MULTI-POLE IDENTIFIATION SHEME SEE TABLE A DEPTH BEHIND PANEL FAE +.00 [+.05] [-.00].6 DIA [Ø.0] N ±.00 ±.76.5 [8.58] PUSH-IN STUD POLE POLE MATING HOLE FIG. A.0 [.8] TYP.5 [.8] TYP MAIN AUX. ** SWITH TAB (Q.) SREW (#8-) PUSH-IN STUD ROUND Q. TYPE TABLE A TERMINAL DESRIPTION DOUBLE SOLDER TURRET TYPE DEPTH BEHIND * PANEL FAE.95 [9.57].99 [50.60].50 [6.6].097 [5.6].087 [5.0] *DEPTH INLUDES BEHIND PANEL HEX NUT AS SUPPLIED ON ALL UNITS. **WHEN ALLED FOR ON MULTI-POLE UNITS, ONLY ONE AUX. SWITH IS RMALLY SUPPLIED, MOUNTED AS SHOWN IN FIG. A All dimensions are in inches [millimeters]. Tolerance ±.05 [.8] unless otherwise specified. 7

30 M-Series Pushbutton Form & Fit Drawings PUSH-PULL ATUATOR STYLE SINGLE POLE ±.00 ± [7.69].5 [.8].75 [.9] ±.00 ± [7.7] /8" 8- THD. FLAT ATUATOR OLOR VISIBLE IN POSITION ONLY ±.00 ± [.70] ( SHOWN) ±.00 ± [7.] ON.00 [0.6] ±.00 ± [7.09] ±.00 ±.76.5 [8.58] ±.05 ±.8.70 [9.0] TAB (Q..) TERMINALS SHOWN FOR TERMINAL DETAILS SEE IRUIT AND TERMINAL DIAGRAMS. DOUBLE POLE /8" 8- THD..5 [.8] ±.00 ± [9.].75 [.9] ±.00 ± [.] FLAT ATUATOR OLOR VISIBLE IN POSITION ONLY ±.00 ± [.70] (SHOWN) ±.00 ± [7.] ON ±.00 ±.76.5 [8.58] ±.05 ±.8.00 [0.6].70 [9.0] ±.00 ± [7.09] TAB (Q..) TERMINALS SHOWN FOR TERMINAL DETAILS SEE IRUIT AND TERMINAL DIAGRAMS..65 [5.88] PUSH-TO-RESET ATUATOR STYLE ±.00 ± [5.59] ±.00 ±.76 FLUSH ON MOUNTING DETAILS ±.00 ±.05.6 [.] [9.5] DIA PUSH-PULL, PUSH TO RESET SNAP-IN BUSHING ATUATOR STYLE SEE TE.65 [5.87] DIA.5[.8] ±.00 ± [5.59] ±.00 ±.76 FLUSH ON SNAP-IN BUSHING PANEL HARDWARE.00 [0.6].9 [.55].098 [.9] BUTTON MARKING ORIENTATION (PUSH-PULL ONLY) HEX NUT [.56].5 [.56].078 [.98] MARKING ODE:.5 [.05] DIA PANEL DRESS NUT All dimensions are in inches [millimeters]. Tolerance ±.00 [.5] unless otherwise specified. Available with Push-Pull or Push-to-Reset Actuators. 8

31 M-Series Rocker ircuit & Terminal Diagrams SERIES TRIP SERIES TRIP W/ ILLUMINATED ROKER TERMINAL DIMENSIONAL DETAIL TAB (Q..) TERMINAL SREW TERMINAL #8- WITH UPTURNED LUGS MAIN TERM'S. (SEE TABLE A) ±.5 [.7] 7.00 [77.8] LONG RED(+), BLAK(-) LEADS.50 [6.5].75 [9.5] SWITH ONLY SWITH ONLY W/ ILLUMINATED ROKER.70 [9.0].069 [.75] DIA.0 [0.] SREW TERMINAL #8- BUS PUSH-IN STUD TERMINAL.50[8.89] SERIES TRIP W/ AUXILIARY SWITH +.00 [+.05] [-.00].6 DIA [Ø.0].75 [9.5].000 [5.].95 [.].9 [9.97]* N AUX SWITH TERM'S PUSH-IN STUD MATING HOLE.0 [0.].00 [.5].5 [.9].50[8.89] SEE TABLE A DEPTH BEHIND PANEL FAE.750 [9.05] AUXILIARY SWITH TERMINALS *ENTER OF PUSH-IN STUD ONTAT AREA.50 [8.86] REF..65 [.9].55 [.9].5 [8.58] TYP..0 [.8] TYP..5 [.8] TYP..060 DIA [Ø.5] DOUBLE SOLDER TURRET TYPE ROUND QUIK-ONNET TYPE.058 DIA [Ø.7] MAIN * AUX. SWITH TABLE - A TERMINAL DESRIPTION TAB (Q..) SREW (#8-)** PUSH-IN STUD DOUBLE SOLDER TURRET TYPE ROUND Q.. TYPE DEPTH BEHIND PANEL FAE.900 [8.6].90 [9.8].50 [6.6].05 [5.9].05 [5.69] * AUX. SWITH IS T AVAILABLE ON SINGLE POLE ILLUMINATED UNITS. WHEN ALLED FOR ON MULTI-POLE UNITS, ONLY ONE AUX. SWITH IS RMALLY SUPPLIED, MOUNTED AS SHOWN IN FIG. A OR FIG. B. **REOMMENDED TIGHTENING TORQUE -5 IN LBS [.-.7 NM] All dimensions are in inches [millimeters]. Tolerance ±.05 [.8] unless otherwise specified. Schematic shown represents current trip circuit. POLE FIG. A MULTI-POLE IDENTIFIATION SHEME VISI-, SINGLE OLOR & ILLUMINATED OPTIONS ONLY N POLE VISI-ON OPTION ONLY POLE N FIG. B POLE 9

32 M-Series Rocker Form & Fit Drawings INDIATE "ON" (VISI-ON).770 [9.56] SINGLE POLE.70 [9.0] MAX. ±.00 [±.508].50 [8.86].5 [.8] ±.00 [±.508].680 [7.7] SEE TE [.6] ON.560 [9.6] ±.00 [±.76].5 [8.58].75 [.9].00 [0.6] SEE TE #.00 [.5] ±.00 [±.76].900 [8.6] ±.05 [±.8].70 [9.0] TAB (Q..) TERMINALS SHOWN. FOR TERMINAL DETAILS SEE IRUIT AND TERMINAL DIAGRAMS DOUBLE POLE.70 [9.0] MAX..9 [5.] ±.00 [±.508].50 [8.86].5 [.8] ±.00 [±.508].0 [.].970 [.6] ON.560 [9.6] ±.00 [±.76].5 [8.58].75 [.9].00 [0.6].00 [.5].70 [9.0].65 [5.88] ±.00 [±.508].680 [.67] ±.00 [±.76].900 [8.6] INDIATE "" (VISI-) AND SINGLE OLOR SINGLE POLE DOUBLE POLE ON ON SEE TE 5 ANGLED ROKER STYLE SINGLE OLOR FLAT ROKER STYLE ROKERGUARD ONFIGURATION DIMENSIONS ALSO APPLY TO DOUBLE POLE ±.00 ± [9.] ±.00 ± [9.] ±.00 ± [7.] ±.00 ± [7.75] ON ±.00 ± [6.67] SEE TE # SINGLE POLE PANEL UT - OUT DETAIL DOUBLE POLE PANEL THIKNESS DIM. A DIM. A DIM. A.06 [.57].85 [5.8].09 [.6].0 [6.07] ±.005 ±. ±.005 ±..5 [.8].60 [7.08].7 [8.0].9 [.76] Dimensions apply to all variations shown. Notice that circuit breaker line & load terminal orientation on indicate is opposite of indicate ON. I-O, ON- or dual legends available for vertical or horizontal mounting. For pole orientation with horizontal legend, rotate front view clockwise 90. All dimensions are in inches [millimeters]. Tolerance ±.00 [.5] unless otherwise specified. 0

33 M-Series Rocker Supplementary Diagrams ONE POLE ROKER AND AUXILIARY SWITH OPTIONS FIG-A N-ILLUMINATED (SINGLE OLOR AND VISI-) ROKER OPTIONS WITH AUXILIARY SWITH FIG-B N- ILLUMINATED (VISI-ON) OPTION ONLY WITH AUXILIARY SWITH FIG- ALL-ROKER OPTIONS WITHOUT AUXILIARY SWITH (VISI-ON) (VISI-) AND SINGLE OLOR N N O N O N (VISI-ON) (VISI-) AND SINGLE OLOR AVAILABLE IRUIT OPTIONS: SERIES TRIP OR "SWITH ONLY" SERIES TRIP OR "SWITH ONLY" SERIES TRIP OR "SWITH ONLY" TWO POLE ROKER AND AUXILIARY SWITH OPTIONS FIG-D ILLUMINATED AND N-ILLUMINATED (SINGLE OLOR AND VISI-) ROKER OPTIONS WITH () AUXILIARY SWITH FIG-E N-ILLUMINATED (VISI-ON) OPTION ONLY WITH () AUXILIARY SWITH FIG-F ALL-ROKER OPTIONS WITHOUT AUXILIARY SWITH (VISI-ON) (VISI-) AND SINGLE OLOR N N O N O N (VISI-ON) (VISI-) AND SINGLE OLOR AVAILABLE IRUIT OPTIONS: POLE SERIES TRIP OR "SWITH ONLY" POLE SERIES TRIP OR "SWITH ONLY" POLE SERIES TRIP OR "SWITH ONLY" POLE SERIES TRIP OR "SWITH ONLY" POLE SERIES TRIP OR "SWITH ONLY" POLE SERIES TRIP OR "SWITH ONLY" MULTI-POLE BREAKERS ARE AVAILABLE WITH A MAXIMUM OF AUXILLIARY SWITH MOUNTED AS SHOWN ABOVE POLE DESIGNATIONS FOR HORIZONTAL MOUNTING/LEGEND - ALL ROKER STYLES (VISI-ON) (VISI-ON) POLE POLE (VISI- AND SINGLE OLOR) (VISI- AND SINGLE OLOR)

34 A-Series General Specifications ompact size and well known for its proven reliability, the A- Series utilizes the hydraulic magnetic principle which provides precise operation and performance even when exposed to extremely hot and/or cold application environments. When aesthetics demand a clean contemporary and functional design, the visi-rocker two-color actuator can be specified. A rockerguard and push-to-reset bezel help prevent inadvertent actuation. A specially constructed version is now available for applications requiring E markings. The A-series is used in many telecommunications and marine applications. -6 poles (handle), - poles (rocker) amps, up to 77 VA or 80 VD, with a choice of time delays, terminals and actuator colors. Agency ertifications UL Recognized UL Standard 077 UL Standard 508 UL Standard 500 omponent Recognition Program as Protectors, Supplementary (Guide QVNU, File E75596) Switches, Industrial ontrol (Guide NRNT, File E868) Protectors, Supplementary for Marine Electrical & Fuel Systems (Guide PEQZ, File E75596) Ignition Protection UL Listed UL Standard 89A SA ertified VDE ertified ommunications Equipment (Guide DITT, File E8995) omponent Supplementary Protector under lass 5 0, FIle SA Standard. No. 5 EN609, VDE 06 under File No. 057 Electrical Table A: Lists UL Recognized & SA ertified configurations and performance capabilities as a omponent Supplementary Protector. A-SERIES TABLE A: OMPONENT SUPPLEMENTARY PROTETOR VOLTAGE URRENT RATING INTERRUPTING APAITY(AMPS) FULL GENERAL UL / SA IRUIT MAX PURPOSE WITH WITHOUT ONFIGURATION RATING FREQUENY PHASE AMPS AMPS BAKUP FUSE BAKUP FUSE 65 D D D /50 50 / /50 50 / SERIES / / / DUAL OIL SHUNT RELAY SWITH ONLY / / D / 60 & / 60 & / D / 60 & / 60 & / D / 60 & / 60 & / D D / / / / Notes for Table A: Requires branch circuit backup with a UL LISTED Type K5 or RK5 fuse (5A minimum) at no more than times the rating of the protector. Same as note, except that backup fuse is limited to 80 A maximum. pole protector required (with one pole per power line) for: 50/5 VA, 5/50 VA and 08Y/0 VA Power Systems. pole protector required for : 5 VA, Ø Power System.

35 A-Series General Specifications Electrical Table B: Lists UL Recognized, SA, VDE & TUV ertified configurations & performance capabilities as a omponent Supplementary Protector. A-SERIES TABLE B: OMPONENT SUPPLEMENTARY PROTETOR VOLTAGE URRENT RATING INTERRUPTING APAITY (AMPS) FULL GENERAL UL / SA VDE TUV IRUIT MAX PURPOSE WITH WITHOUT (Inc) WITH (Icn) WITHOUT (Inc) WITH (Icn) WITHOUT ONFIGURATION RATING FREQUENY PHASE AMPS AMPS BAKUP FUSE BAKUP FUSE BAKUP FUSE BAKUP FUSE BAKUP FUSE BAKUP FUSE VDE ONSTRUTION TES 80 D Handle Version Pole Only 80 D Handle Version Pole Only 80 D Rocker Version - Poles 80 D Rocker Version Pole Only 80 D Rocker Version Pole Only SERIES 50 50/60 & Rocker Version - Poles 50 50/60 & Rocker Version - Poles 50 50/ Rocker Version - Poles 50 50/ Rocker Version - Poles 50 50/ Rocker Version Poles Only 80 D DUAL OIL 50 50/60 & /60 & Rocker Version - Poles 50 50/ Rocker Version - Poles 80 D Handle Version Pole Only 80 D Rocker Version - Poles SHUNT 50 50/60 & Rocker Version - Poles 50 50/60 & Rocker Version - Poles 50 50/ Rocler Version - Poles Notes for Table B: General Purpose Ratings for UL/SA Only. Requires branch circuit backup with a UL LISTED Type K5 or RK5 fuse (5A minimum) at no more than times the rating of the protector. Same as note, except that backup fuse is limited to 80 A maximum. Table : Lists UL Recognized, SA ertified configurations and performance capabilities as Protectors, Supplementary for Marine Electrical and Fuel Systems (Guide PEQZ, File E75596). Ignition Protected per UL 500. UL lassified Small raft Electrical Devices, Marine in accordance with ISO 886 (Guide UZMK, File MQ55) as Marine Supplementary Protectors. A-SERIES TABLE : UL500 (MARINE IGNITION PROTETED) INTERRUPTING VOLTAGE URRENT APAITY RATING (AMPS) IRUIT MAX FULL WITHOUT ONFIGURATION RATING FREQ. PHASE AMPS BAKUP FUSE D SERIES 65 D / / / Notes for Table : Available with special catalog number only (consult factory). pole protector required (with one pole per power line) for: 50/5 VA, 5/50 VA and 08Y/0 VA Power Systems. pole protector required for : 5 VA, Ø Power System. Table D: Lists UL Listed configurations and performance capabilities as ircuit Breakers for use in ommunications Equipment (Guide DITT, File E8995), under UL89A. A-SERIES TABLE D: UL89A (OMMUNIATIONS EQUIPMENT) INTERRUPTING VOLTAGE URRENT APAITY RATING (AMPS) IRUIT MAX UL GENERAL WITHOUT ONFIGURATION RATING FREQUENY PURPOSE AMPS BAKUP FUSE SERIES 80 D

36 A-Series General Specifications Electrical Mechanical Maximum Voltage 77VA 50/60 Hz, 80VD urrent Ratings Standard current coils: 0.00, 0.50, 0.500, 0.750,.00,.50, 5.00, 7.50, 0.0, 5.0, 0.0, 5.0, 0.0, 5.0, 0.0, Other ratings available - consult ordering scheme. Standard Voltage oils D-6V, V; A-0V, Other ratings available, consult ordering scheme. Auxiliary Switch Rating SPDT; 0. A - 50VA,.0 A-65VD/0.5 A - 80 VD, 0.A - 5VA (with gold contacts). Insulation Resistance Minimum: 00 Megohms at 500 VD Dielectric Strength UL, SA - 500V 60 Hz for one minute between all electrically isolated terminals. A-Series rocker circuit breakers comply with the 8mm spacing & 750V dielectric requirements from hazardous voltage to operator accessible surfaces per EN and VDE Resistance, Impedance Values from Line to Load Terminal - based on Series Trip ircuit Breaker. O H M S RESISTANE, IMPEDANE VALUES from Line to Load Terminals (Values Based on Series Trip ircuit Breaker) URRENT TOLERANE (AMPS) (%) ± 5% ± 5% ± 5% Endurance Trip Free Trip Indication Physical Number of Poles Internal ircuit onfigurations Weight Standard olors Environmental 0,000 ON- 6 per minute; with rated urrent & Voltage. All A-Series ircuit Breakers will trip on overload, even when the actuator is forcibly held in the ON position. The operating actuator moves positively to the position when an overload causes the circuit breaker to trip. When mid-trip handle is specified, the handle moves to the mid position on electrical trip of the circuit breaker. When mid-trip handle with alarm switch is specified, the handle moves to the mid position & the alarm switch actuates when the circuit breaker is electrically tripped. - 6 Poles (handle) and - poles (rocker) at 0 Amps or less. and poles at Amps thru 50 Amps. Series, (with or without auxiliary switch), Shunt and Relay with current or voltage trip coils, Dual oil, Switch Only with or without auxiliary switch. Approximately 65 grams/pole. (Approximately. ounces/pole) Housing - Black; Actuator- See Ordering Scheme. Multiple of Rated urrent 5x x I r AMPERE RATING 60 Hz / ycle Inrush Pulse Tolerance Time Delay urves, & 6 (50 Amps Max.) 8. Time Delay urves, & 6 (50 Amps Max.) t 6.67 Time in Milliseconds Multiple of Rated urrent x 0x I r 50 Hz / ycle Inrush Pulse Tolerance Time Delay urves, & 6 (50 Amps Max.) Time Delay urves, & 6 (50 Amps Max.) Time in Milliseconds t Designed and tested in accordance with requirements of specification MIL-PRF-5569 & MIL-STD-0 as follows: Shock Withstands 00 Gs, 6ms, sawtooth while carrying rated current per Method, Test ondition I. Instantaneous and ultra-short curves 90% of rated current. Vibration Withstands 0.060" excursion from 0-55 Hz, and 0 Gs Hz, at rated current per Method 0, Test ondition A. Instantaneous and ultrashort curves tested at 90% of rated current. Moisture Resistance Method 06D; ten -hour + 5 to +65, 80-98% RH , 85% RH. Salt Spray Method 0, ondition A (90-95% 5% Nal Solution, 96 hrs). Thermal Shock Method 07D, ondition A (Five -55 to +5 to +85 to +5 ). Operating Temperature -0 to +85

37 A Series 5 Aux/Alarm Switch A-Series Handle UL Recognized Ordering Scheme A B B Actuator Poles ircuit 6 Frequency & Delay 7 urrent Rating 8 Terminal 9 Actuator olor 0 Mounting/ Barriers Agency Approval SERIES A ATUATOR A Handle, one per pole B Handle, one per multipole unit S Mid-Trip Handle, one per pole T Mid-Trip Handle, one per pole & Alarm Switch POLES One Two IRUIT A Switch Only (No oil) B Series Trip (urrent) Series Trip (Voltage) D Shunt Trip (urrent) E Shunt Trip (Voltage) 5 AUXILIARY/ALARM SWITH 5 0 w/o Aux Switch S.P.D.T., 0.09 Q.. Term. S.P.D.T., 0.0 Q.. Term. S.P.D.T., 0.9 Solder Lug S.P.D.T., 0.0 Q.. Term. (Gold ontacts) 6 FREQUENY & DELAY 0 D 50/60Hz, Switch Only 0 6 D Instantaneous D Ultra Short D Short D Medium 6 D Long /60Hz Instantaneous 50/60Hz Ultra Short 50/60Hz Short0 50/60Hz Medium 6 50/60Hz Long Three Four F G H, K, 5 Five 6 Six Relay Trip (urrent) Relay Trip (Voltage) Dual oil with Shunt Trip Voltage oil Dual oil with Relay Trip Voltage oil 5 S.P.S.T., 0.09 Q.. Term.(Gold ontacts) 6 S.P.S.T., 0.9 Solder Lug 7 S.P.S.T., 0.0 Q.. Term.(Gold ontacts) 8 S.P.S.T., 0.87 Q.. Term. 9 S.P.D.T., 0.87 Q.. Term. 0 D, 50/60Hz Instantaneous D, 50/60Hz Ultra Short D, 50/60Hz Short D, 50/60Hz Medium 6 D, 50/60Hz Long 7 50/60Hz Short, Hi-Inrush 7 50/60Hz Medium, Hi-Inrush /60Hz Long, Hi-Inrush 5 7 D, Short,Hi-Inrush 5 7 D,Medium, Hi-Inrush 56 7 D, Long, Hi-Inrush Actuator ode: A: Handle tie pin spacer(s) and retainers provided unassembled with multi-pole units. B: Handle location as viewed from front of breaker: pole - left pole pole - center pole pole - two handles at center poles 5 pole - three handles at center poles 6 pole - four handles at center poles S: Handle moves to mid-position only upon electrical trip of the breaker. Available with circuit codes B,, D, E, F, G, H and K. T: Handle moves to mid-position and alarm switch activates only upon electrical trip of the breaker. Available with circuit codes B &. Switch Only circuits, rated up to 50 amps and 6 poles, and only available with VDE ertification when tied to a protected pole (ircuit ode B,, D or H.), For.0 to 0 amps, select urrent ode 60. For 5-50 amps, select urrent ode 650. Available with terminal odes, and. urrent Rating limited to 0 amps maximum. onsult factory for available Dual oil options, as special catalog number is required. With Shunt construction, Dual oils will trip instantaneously on line voltage. Dual coils require 0VA minimum power to trip and are rated for intermittent duty only. 5 Auxiliary Switch breakers with Series Trip & Switch Only circuits: 0A - supplied with standard half shells. 5-50A - supplied with extended boat (B-Style) half shells. On multi-pole breakers, one auxilary switch is supplied, mounted in the extreme right pole. 6 Separate pole type voltage coils not rated for continuous duty. Available only with delay codes 0 and 0. 7 Available with ircuit odes B & D only. VDE ertified to 0 amps. UL Recognized and SA ertified to 50 amps. 8 VDE ertification available with single pole breakers with D Delay only. UL Recognition and SA ertification available in one and two pole breakers. 9 Screw Terminals are recommended on ratings greater than 0 amps. Ratings over 0 amps are only available with Terminal odes 5, 9, G, H, M and Q.. 0 Terminal ode : VDE ertification up to 5 amps and UL Recognition and SA ertification up to 0 amps, but not recommended over 0 amps. Terminal odes, 5, E and H (Bus Type) with VDE, are supplied with Lock Washers, and Terminal ode M (M6 Threaded Stud) with VDE is supplied with Lock and Flat Washers. These breakers are only VDE ertified when the washers are used. Terminal ode L: VDE ert. available up to amps. UL Rec. & SA ert. available up to 0 amps. Single pole breakers with Terminal ode P (Printed ircuit Board) are available up to 0 amps with VDE ertification and 50 amps with UL Recognition and SA ertification, with ircuit odes A, B and. Two pole breakers with Terminal ode P (Printed ircuit Board) are available up to 0 amps with UL Recognition and SA ertification with ircuit odes A, B and. Single pole only. 7 URRENT RATING (AMPERES) TERMINAL 9 0 Push-On 0.50 Tab (Q..) Screw 8- w/upturned lugs Screw 8- (Bus Type) Screw 0- w/upturned lugs 5 Screw 0- (Bus Type) 6 Screw 8- w/upturned lugs and 0 bend 7 Screw 8- (Bus Type) and 0 bend 8 Screw 0- w/upturned lugs and 0 bend 9 Screw 0- (Bus Type) and 0 bend B Screw M5 w/upturned lugs Screw M w/upturned lugs OR VOLTAGE OIL (MINAL RATED VOLTAGE) 6 A06 6 D A D J A A D A8 8 D J8 8 A A8 8 D A65 65 D J A A D J06 6 A J8 8 A MOUNTING/BARRIERS MOUNTING STYLE BARRIERS Threaded Inserts, per pole 6- x 0.95 inches no A 6- X 0.95 inches yes ISO M x 5mm no B ISO M x 5mm yes Front panel Snap-In, 0.75 wide bezel 5 without Handleguard no 6 without Handleguard yes Front panel Snap-In, 0.96 wide bezel 7 without Handleguard on -pole units;.05 bezel no overhang/ side on multipole units 8 without Handleguard on -pole units;.05 bezel yes overhang/side on multipole units AGENY APPROVAL UL Recognized & SAertified D VDE ertified, UL Recognized & SAertified E TUV ertified, UL Recognized & SAertified I UL Rec. STD 077, UL Rec. 500 (ignition protected), & SAertified E F G H L M Q R T P S J65 K0 L0 65 A 0 A 0 A Screw M (Bus Type) Screw M5 w/upturned lugs and 0 bend Screw M5 (Bus Type) and 0 bend Screw M5 (Bus Type) 0.50 Q../ Solder Lug M6 Threaded Stud Push-In Stud Screw M w/upturned lugs and 0 bend Screw M (Bus Type) and 0 bend Printed ircuit Board Terminals Push-On 0.0 Tab (Q..) 9 ATUATOR OLOR & LEGEND Actuator olor I-O ON- Dual Legend olor White A B Black Black D White Red F G White Green H J White Blue K L 5 White Yellow M N 6 Black Gray P Q 7 Black Orange R S 8 Black Black (short handle) T U 9 White 5

38 A-Series Handle UL89A Ordering Scheme A Series A B 0 50 B M Actuator Poles ircuit 5 Aux/Alarm Switch 6 Frequency & Delay 7 urrent Rating 8 Terminal 9 Actuator olor 0 Mounting/ Barriers Max. Appl. Rating T Agency Approval SERIES A ATUATOR A Handle, one per pole S Mid-Trip Handle, one per pole T Mid-Trip Handle, one per pole & Alarm Switch POLES One Two Three Four IRUIT B Series Trip (urrent) 5 AUXILIARY/ALARM SWITH 0 w/o Aux Switch S.P.D.T., 0.09 Q.. Term. S.P.D.T., 0.0 Q.. Term. S.P.D.T., 0.9 Solder Lug 6 FREQUENY & DELAY D Ultra Short D Short D Medium 6 D Long 7 S.P.S.T., 0.0 Q.. Term.(Gold ontacts) 8 S.P.S.T., 0.87 Q.. Term. 9 S.P.D.T., 0.87 Q.. Term. 5 D, Short,Hi-Inrush 5 D, Medium, Hi-Inrush 56 D, Long, Hi-Inrush 8 TERMINAL 5 6 Push-On 0.50 Tab (Q..) Screw 8- w/upturned lugs 7 Screw 8- (Bus Type) Screw 0- w/upturned lugs 5 7 Screw 0- (Bus Type) 6 Screw 8- w/upturned lugs and 0 bend 7 Screw 8- (Bus Type) and 0 bend 8 Screw 0- w/upturned lugs and 0 bend 9 ATUATOR OLOR LEGEND ON- Dual Legend olor White B Black Black D White Red G White Green J White Blue L 5 White Yellow N 6 Black Gray Q 7 Black Orange S 8 Black Black (short handle) 9 T 9 White 9 Screw 0- (Bus Type) and 0 bend B Screw M5 w/upturned lugs F Screw M5 w/upturned lugs and 0 bend G Screw M5 (Bus Type) and 0 bend H Screw M5 (Bus Type) M 7 M6 Threaded Stud P 8 Printed ircuit Board Terminals Q Push-In Stud 7 URRENT RATING (AMPERES) MOUNTING/BARRIERS MOUNTING STYLE BARRIERS Threaded Insert, per pole 6- x 0.95 inches no A 6- X 0.95 inches yes ISO M x 5mm no B ISO M x 5mm yes Front panel Snap-In, 0.75 wide bezel 5 without Handleguard no 6 without Handleguard yes Front panel Snap-In, 0.96 wide bezel 7 without Handleguard on -pole no units;.05 bezel overhang/ side on multipole units 8 without Handleguard on -pole yes units;.05 bezel overhang/ side on multipole units MAXIMUM APPLIATION RATING M 80 D AGENY APPROVAL T UL89A LISTED K UL89A LISTED, VDE ERTIFIED Actuator ode: A: Handle tie pin spacer(s) and retainers provided unassembled with multi-pole units. S: Handle moves to mid-position only upon electrical trip of the breaker. T: Handle moves to mid-position and alarm switch activates only upon electrical trip of the breaker. On multi-pole breakers, one auxiliary switch is supplied, mounted in the extreme right pole. VDE ertified to 0 amps. UL89A Listed to 50 amps. VDE ertification available with single pole breakers only. UL89A Listing available with one and two pole breakers. 5 Screw Terminals are recommended on ratings greater than 0 amps. Ratings over 0 amps are only available with Terminal odes 5, 9 G, H, M and Q. 6 Terminal ode (Push-On) available up to 5 amps with VDE ertification and 0 amps with UL89A Listing, but is not recommended over 0 amps. 7 Terminal odes, 5 and H (Bus Type) with VDE, are supplied with Lock Washers, and Terminal ode M (M6 Threaded Stud) with VDE is supplied with Lock and Flat Washers. These breakers are only VDE ertified when the washers are used. 8 Single pole breakers with Terminal ode P (Printed ircuit Board) are available up to 0 amps with VDE ertification and 50 amps with UL89A Listing. 9 Single pole only. 6

39 A Series Actuator Poles ircuit 5 Aux/Alarm Switch A-Series Handle WORLD Ordering Scheme A B 0 50 A P 6 Frequency & Delay 7 urrent Rating 8 Terminal 9 Actuator olor 0 Mounting/ Barriers Agency Approval SERIES A ATUATOR A Handle, one per pole S Mid-Trip Handle, one per pole T Mid-Trip Handle, one per pole & Alarm Switch POLES One Two IRUIT A Switch Only (No oil) B Series Trip (urrent) Series Trip (Voltage) 5 AUXILIARY/ALARM SWITH 5 0 w/o Aux Switch S.P.D.T., 0.0 Q.. Term. S.P.D.T., 0.9 Solder Lug 6 FREQUENY & DELAY 0 D 50/60Hz, Switch Only 0 6 D Instantaneous D Ultra Short D Short D Medium 6 D Long /60Hz Instantaneous 50/60Hz Ultra Short 50/60Hz Short0 50/60Hz Medium 6 50/60Hz Long Three Four D E H, 5 Five 6 Six Shunt Trip (urrent) Shunt Trip (Voltage) Dual oil with Shunt Trip Voltage oil S.P.D.T., 0.0 Q.. Term. (Gold ontacts) 0 D, 50/60Hz Instantaneous D, 50/60Hz Ultra Short D, 50/60Hz Short D, 50/60Hz Medium 6 D, 50/60Hz Long 7 50/60Hz Short, Hi-Inrush 7 50/60Hz Medium, Hi-Inrush /60Hz Long, Hi-Inrush 5 7 D, Short,Hi-Inrush 5 7 D,Medium, Hi-Inrush 56 7 D, Long, Hi-Inrush 7 URRENT RATING (AMPERES) TERMINAL 9 0 Push-On 0.50 Tab (Q..) Screw 8- w/upturned lugs Screw 8- (Bus Type) Screw 0- w/upturned lugs 5 Screw 0- (Bus Type) 6 Screw 8- w/upturned lugs and 0 bend 7 Screw 8- (Bus Type) and 0 bend 8 Screw 0- w/upturned lugs and 0 bend 9 Screw 0- (Bus Type) and 0 bend OR VOLTAGE OIL (MINAL RATED VOLTAGE) 6 A06 6 D A D J A A D A8 8 D J8 8 A A8 8 D A65 65 D J A A D J06 6 A J8 8 A B E F G H M Q R T J65 K0 L0 65 A 0 A 0 A Screw M5 w/upturned lugs Screw M w/upturned lugs Screw M (Bus Type) Screw M5 w/upturned lugs and 0 bend Screw M5 (Bus Type) and 0 bend Screw M5 (Bus Type) M6 Threaded Stud Push-In Stud Screw M w/upturned lugs and 0 bend Screw M (Bus Type) and 0 bend 9 ATUATOR OLOR & LEGEND Actuator olor I-O Dual Legend olor White A Black Black White Red F White Green H White Blue K 5 White Yellow M 6 Black Gray P 7 Black Orange R 8 Black Actuator ode: A: Handle tie pin spacer(s) and retainers provided unassembled with multi-pole units. S: Handle moves to mid-position only upon electrical trip of the breaker. Available with circuit codes B,, D, E, and H. T: Handle moves to mid-position and alarm switch activates only upon electrical trip of the breaker. Available with circuit codes B &. Switch Only circuits, rated up to 50 amps and 6 poles, and only available when tied to a protected pole (ircuit ode B,, D or H.), For.0 to 0 amps, select urrent ode 60. For 5-50 amps, select urrent ode 650. Available with terminal odes, and. urrent Rating limited to 0 amps maximum. onsult factory for available Dual oil options, as special catalog number is required. With Shunt construction, Dual oils will trip instantaneously on line voltage. Dual coils require 0VA minimum power to trip and are rated for intermittent duty only. 5 On multi-pole breakers, one auxilary switch is supplied, mounted in the extreme right pole. 6 Separate pole type voltage coils not rated for continuous duty. Available only with delay codes 0, 0 & 0. 7 Available with ircuit odes B & D only and up to 0 amps. 8 Available up to two poles with A or D delays. 9 Screw Terminals are recommended on ratings greater than 0 amps. Ratings over 0 amps are only available with Terminal odes 5, 9, G and H. 0 Terminal ode : TUV ertification up to 0 amps, but not recommended over 0 amps. Terminal odes, 5, 7, 9, E, G and H (Bus Type) are supplied with Lock Washers. These breakers are ONLY TUV ertified when the washers are used. Terminal ode M (M6 Threaded Stud) with TUV is supplied with lock and flat washers. 0 MOUNTING/BARRIERS MOUNTING STYLE BARRIERS Threaded Inserts, per pole 6- x 0.95 inches no A 6- X 0.95 inches yes ISO M x 5mm no B ISO M x 5mm yes Front panel Snap-In, 0.75 wide bezel 5 without Handleguard no 6 without Handleguard yes Front panel Snap-In, 0.96 wide bezel 7 without Handleguard on -pole units;.05 bezel no overhang/ side on multipole units 8 without Handleguard on -pole units;.05 bezel yes overhang/side on multipole units AGENY APPROVAL P TUV ertified, UL Recognized & SAertified Q UL Rec. STD 077, UL Rec. 500 (ignition protected), & SAertified 7

40 A Series Actuator Poles ircuit 5 Aux/Alarm Switch A-Series Rocker UL Recognized Ordering Scheme F B 0 60 D 6 Frequency & Delay 7 urrent Rating 8 Terminal 9 Actuator olor 0 Mounting/ Barriers Agency Approval SERIES A ATUATOR Two olor Visi-Rocker Indicate ON, vertical legend D Indicate ON, horizontal legend E Indicate ON, no legend F Indicate, vertical legend G Indicate, horizontal legend H Indicate, no legend Push-To-Reset, Visi-Rocker N Indicate, vertical legend O Indicate, horizontal legend P Indicate, no legend VERTIAL STYLE HORIZONTAL STYLE INDIATE OLOR LOATION Single color J Vertical legend K Horizontal legend L No legend Push-To-Reset, Single color R Vertical legend U Horizontal legend ROKER STYLE DESRIPTIONS INDIATE "ON" INDIATE "" SINGLE OLOR ODE "" ODE "F", "N" ODE "J", "R" ODE "D" ODE "G", "O" ODE "K", "U" 7 URRENT RATING (AMPERES) OR VOLTAGE OIL (MINAL RATED VOLTAGE) A06 6 D A D J A A D A8 8 D J8 8 A A8 8 D A65 65 D J A A D J06 6 A J8 8 A J65 K0 L0 65 A 0 A 0 A POLES One Two Three IRUIT A Switch Only (No oil) B Series Trip (urrent) Series Trip (Voltage) D Shunt Trip (urrent) E Shunt Trip (Voltage) 5 AUXILIARY/ALARM SWITH 6, 7 0 w/o Aux Switch S.P.D.T., 0.09 Q.. Term. S.P.D.T., 0.0 Q.. Term. S.P.D.T., 0.9 Solder Lug S.P.D.T., 0.0 Q.. Term. (Gold ontacts) 6 FREQUENY & DELAY 0 D 50/60Hz, Switch Only 0 8 D Instantaneous D Ultra Short D Short D Medium 6 D Long /60Hz Instantaneous 50/60Hz Ultra Short 50/60Hz Short 50/60Hz Medium F G H, 5 K, 5 Relay Trip (urrent) Relay Trip (Voltage) Dual oil with Shunt Trip Voltage oil Dual oil with Relay Trip Voltage oil 5 S.P.S.T., 0.09 Q.. Term.(Gold ontacts) 6 S.P.S.T., 0.9 Solder Lug 7 S.P.S.T., 0.0 Q.. Term.(Gold ontacts) 8 S.P.S.T., 0.87 Q.. Term. 9 S.P.D.T., 0.87 Q.. Term. 6 50/60Hz Long 0 D, 50/60Hz Instantaneous D, 50/60Hz Ultra Short D, 50/60Hz Short D, 50/60Hz Medium 9 50/60Hz Short, Hi-Inrush 9 50/60Hz Medium, Hi-Inrush /60Hz Long, Hi-Inrush 5 9 D, Short,Hi-Inrush 5 9 D,Medium, Hi-Inrush 56 D, Long, Hi-Inrush Push-To-Reset actuators have portion of rocker shrouded. Multi-pole breakers have all breakers identical except when specifying Aux. switch and/or mixed poles, and have one rocker per breaker. Switch Only circuits, rated up to 50 amps & 6 poles, are available with VDE ertification when tied to a protected pole (ircuit ode B,, D or H.), For.0 to 0 amps, select urrent ode 60. For 5-50 amps, select urrent ode 650. Available with terminal odes, and. urrent Rating limited to 0 amps maximum. 5 onsult factory for Dual oil options, as special catalog number is required. With Shunt construction, Dual oils will trip instantaneously on line voltage. Dual coils require 0VA minimum power to trip and are rated for intermittent duty only. 6 Auxiliary Switch breakers with Series Trip & Switch Only circuits: 0A, are supplied with standard half shells. 0-50A are supplied with extended boat (B-Style) half shells. 7 On multi-pole breakers, one aux. switch is supplied, mounted in the extreme right pole, per figure A, & is supplied with boat (B-style) half shells. 8 Separate pole type voltage coils not rated for continuous duty. Available only with delay codes 0 and 0. 9 Available with ircuit odes B & D only. VDE ertified to 0 amps. UL Recognized and SA ertified to 50 amps. 0 Series Trip current ratings: VDE ertification available with single pole breakers with D Delay only. UL Recognition & SA ertification available in one and two pole breakers. Screw Terminals are recommended on ratings greater than 0 amps. Ratings over 0 amps are only available with Terminal odes 5, 9, G, H, M and Q. Terminal ode : VDE ertification up to 5 amps and UL Recognition and SA ertification up to 0 amps, but not recommended over 0 amps. Terminal odes, 5 E & H (Bus Type) with VDE, are supplied with Lock Washers; Terminal ode M (M6 Threaded Stud) with VDE is supplied with Lock and Flat Washers. These breakers are only VDE ertified when the washers are used. VDE ert. available up to amps. UL Rec. & SA ert. available up to 0 amps. 5 Single pole breakers with Terminal ode P (Printed ircuit Board) are available up to 0 amps with VDE ertification and 50 amps with UL Recognition and SA ertification, with ircuit odes A, B and. Two pole breakers with Terminal ode P (Printed ircuit Board) are available up to 0 amps with UL Recognition and SA ertification with ircuit odes A, B and. 6 Terminal ode S used on voltage coil circuit constructions only. 7 olor shown is visi and legend with remainder of rocker black. 8 Legend on Push-to-reset bezel/shroud is white when single color rocker is ordered. Dual = ON-/I-O legend with actuator codes - G, and J, K, N, O, R, & U. None = no legend with actuator codes H, L, P, V. Rockerguard available with actuator codes - L. Push-to-reset available with actuator codes N, O, P, R, U, V. 8 8 TERMINAL Push-On 0.50 Tab (Q..) Screw 8- w/upturned lugs Screw 8- (Bus Type) Screw 0- w/upturned lugs 5 Screw 0- (Bus Type) 6 Screw 8- w/upturned lugs and 0 bend 7 Screw 8- (Bus Type) and 0 bend 8 Screw 0- w/upturned lugs and 0 bend 9 Screw 0- (Bus Type) and 0 bend B Screw M5 w/upturned lugs Screw M w/upturned lugs AGENY APPROVAL UL Recognized & SAertified D VDE ertified, UL Recognized & SAertified E TUV ertified, UL Recognized & SAertified I UL Rec. STD 077, UL Rec. 500 (ignition protected), & SAertified E F G H L M P 5 Q R S 6 T Screw M (Bus Type) Screw M5 w/upturned lugs and 0 bend Screw M5 (Bus Type) and 0 bend Screw M5 (Bus Type) 0.50 Q../ Solder Lug M6 Threaded Studs Printed ircuit Board Terminals Push-In Stud Screw M w/upturned lugs and 0 bend Push-On 0.0 Tab (Q..) Screw M (Bus Type) and 0 bend 9 ATUATOR OLOR & LEGEND Actuator or Marking: Marking olor: Visi-olor 7 I-O ON- Dual/None Single olor Visi-Rocker White A B Black White Black D White n/a Red F G White Red Green H J White Green Blue K L 5 White Blue Yellow M N 6 Black Yellow Gray P Q 7 Black Gray Orange R S 8 Black Orange 0 MOUNTING/BARRIERS 8 BARRIERS STANDARD ROKER BEZEL,Threaded Insert, per pole 6- x 0.95 inches no A 6- X 0.95 inches (multi-pole units only) yes ISO M x 5mm no B ISO M x 5mm (multi-pole units only) yes ROKERGUARD & PUSH-TO-RESET BEZEL,Threaded Insert, per pole 6- x 0.95 inches no 6- x 0.95 inches (multi-pole units only) yes ISO M x 5mm no D ISO M x 5mm (multi-pole units only) yes FRONT PANEL SNAP-IN BRAKET, 0.7 wide bezel 8 without Rockerguard (multi-pole units only) no H with Rockerguard (multi-pole units only) yes FRONT PANEL SNAP-IN BRAKET, 0.96 wide bezel 9 without Rockerguard (single pole units only) no J with Rockerguard (single pole units only) yes

41 A-Series Rocker UL89A Ordering Scheme A Series F B 0 50 M Actuator Poles ircuit 5 Aux/Alarm Switch 6 Frequency & Delay 7 urrent Rating 8 Terminal 9 Actuator olor 0 Mounting/ Barriers Max. Appl. Rating T Agency Approval SERIES A ATUATOR Two olor Visi-Rocker Indicate ON, vertical legend D Indicate ON, horizontal legend F Indicate, vertical legend G Indicate, horizontal legend Single color J Vertical legend K Horizontal legend Push-To-Reset, Single color R Vertical legend U Horizontal legend POLES One Two Three IRUIT B Series Trip (urrent) 5 AUXILIARY/ALARM SWITH 0 w/o Aux Switch S.P.D.T., 0.09 Q.. Term. S.P.D.T., 0.0 Q.. Term. S.P.D.T., 0.9 Solder Lug 6 FREQUENY & DELAY D Ultra Short D Short D Medium 6 D Long 7 URRENT RATING (AMPERES) VERTIAL STYLE HORIZONTAL STYLE INDIATE OLOR LOATION ROKER STYLE DESRIPTIONS INDIATE "ON" INDIATE "" SINGLE OLOR ODE "" ODE "F", "N" ODE "J", "R" ODE "D" ODE "G", "O" ODE "K", "U" 7 S.P.S.T., 0.0 Q.. Term.(Gold ontacts) 8 S.P.S.T., 0.87 Q.. Term. 9 S.P.D.T., 0.87 Q.. Term. 5 D, Short,Hi-Inrush 5 D, Medium, Hi-Inrush 56 D, Long, Hi-Inrush TERMINAL 6 7 Push-On 0.50 Tab (Q..) Screw 8- w/upturned lugs 8 Screw 8- (Bus Type) Screw 0- w/upturned lugs 5 8 Screw 0- (Bus Type) 6 Screw 8- w/upturned lugs and 0 bend 7 Screw 8- (Bus Type) and 0 bend 8 Screw 0- w/upturned lugs and 0 bend 9 Screw 0- (Bus Type) and 0 bend B Screw M5 w/upturned lugs F Screw M5 w/upturned lugs and 0 bend G Screw M5 (Bus Type) and 0 bend H Screw M5 (Bus Type) M 8 M6 Threaded Stud P 9 Printed ircuit Board Terminals Q Push-In Stud 9 ATUATOR OLOR & LEGEND Actuator or Visi-olor Marking: Marking olor: Single olor olor: ON- Dual/None Rocker/Handle Visi-Rocker White B Black White Black D White n/a Red G White Red Green J White Green Blue L 5 White Blue Yellow N 6 Black Yellow Gray Q 7 Black Gray Orange S 8 Black Orange 0 MOUNTING/BARRIERS STANDARD ROKER BEZEL BARRIERS Threaded Insert, per pole 6- x 0.95 inches no A 6- X 0.95 inches (multi-pole units only) yes ISO M x 5mm no B ISO M x 5mm (multi-pole units only) yes ROKERGUARD & PUSH-TO-RESET BEZEL Threaded Insert, per pole 6- x 0.95 inches no 6- x 0.95 inches (multi-pole units only) yes ISO M x 5mm no D ISO M x 5mm (multi-pole units only) yes FRONT PANEL SNAP-IN BRAKET, 0.7 [8.90mm] wide bezel 8 without Rockerguard (multi-pole units only) no H with Rockerguard (multi-pole units only) yes FRONT PANEL SNAP-IN BRAKET, 0.96 [.8mm] wide bezel 9 without Rockerguard (single pole units only) no J with Rockerguard (single pole units only) yes MAXIMUM APPLIATION RATING M 80 D AGENY APPROVAL T UL89A LISTED K UL89A LISTED, VDE ERTIFIED Push-To-Reset actuators have portion of rocker shrouded. Multi-pole breakers have all breakers identical except when specifying Aux. switch and/or mixed poles, and have one rocker per breaker. Auxiliary Switch breakers with Series Trip & Switch Only circuits: 0A, are supplied with standard half shells. 0-50A are supplied with extended boat (B-Style) half shells. VDE ertified to 0 amps. UL89A Listed to 50 amps. 5 VDE ertification available with single pole breakers only. UL89A Listing available with one and two pole breakers. 6 Screw Terminals are recommended on ratings greater than 0 amps. Ratings over 0 amps are only available with Terminal odes 5, 9, G, H, M and Q. 7 Terminal ode (Push-On) available up to 5 amps with VDE ertification and 0 amps with UL89A Listing, but is not recommended over 0 amps. 8 Terminal odes, 5 and H (Bus Type) with VDE, are supplied with Lock Washers, and Terminal ode M (M6 Threaded Stud) with VDE is supplied with Lock and Flat Washers. These breakers are only VDE ertified when the washers are used. 9 Single pole breakers with Terminal ode P (Printed ircuit Board) are available up to 0 amps with VDE ertification and 50 amps with UL89A Listing. 9

42 A-Series Handle ircuit & Terminal Diagrams TERMINALS IRUIT BREAKER PROFILE IRUIT SHEMATI ANSI SWITH ONLY ( OIL) IRUIT ODE AUX SWITH ODE IRUIT SHEMATI ANSI SERIES TRIP IRUIT ODE AUX SWITH ODE MAIN TERMINALS (SEE TABLE A) A 0 B 0.60 [.66] 5 TERMINALS.50[.] SWITH ONLY ( OIL) WITH AUXILIARY SWITH SERIES TRIP WITH () AUXILIARY/ALARM SWITH.05[5.] TERMINALS N STANDARD AUX. SWITH TERMINALS N ALARM SWITH TERMINALS & STD. AUX. SW. WITH VDE OR >0 AMPS OR AGENY ODE "P" N SHUNT TRIP A STANDARD AUX. SWITH N N0 ALARM SWITH DUAL OIL; SERIES TRIP URRENT OIL, SHUNT TRIP VOLTAGE OIL N0 N B.90[9.9] SHUNT DE 0 VOLTAGE OIL H 0 TERMINALS RELAY TRIP.780[9.8] DUAL OIL; SERIES TRIP URRENT OIL, RELAY TRIP VOLTAGE OIL FG 0 K 0 RELAY VOLTAGE OIL.90[9.9] RELAY All dimensions are in inches [millimeters]. Tolerance ±.05 [.8] unless otherwise specified. Alarm Switch available with.0 x.00 Q.. & Solder Lug Terminals Only. 0

43 +.00 [+.05] [-.00] arling A-Series Handle ircuit & Terminal Diagrams HANDLE POSITION VS. AUX /ALARM SWITH MODE IRUIT BREAKER MODE STANDARD /B HANDLE POSITION AUX. SWITH MODE HANDLE POSITION MID TRIP /B ALARM SWITH MODE 0 0 O N O N ON ON I I ON 0 0 N N ELETRIAL TRIP 0 90 MID TRIP O N N TERMINAL DIMENSIONAL DETAIL & RATING.000 [5.].60[9.].9[9.96].9[9.96].[8.7].6[9.7].60[5.9].9 [9.97] ENTER OF PUSH-IN STUD ONTAT AREA.50[6.5].069[.75] DIA TAB (Q..) 0 AMP.75[9.5] UPTURN LUG #8-0 AMP #0-0 AMP M5 0 AMP M 0 AMP.75[9.5].09DIA [.76].50[6.5].0[.79].05[0.9] BUS Q SOLDER LUG.0 Q M5 STUD #8-0 AMP 0 AMP VOLTAGE OILS 50 AMP #0-50 AMP ONLY.00 [.5].750 [9.05] PUSH-IN STUD 50 AMP.5 [.9] DIA AUXILIARY/ALARM SWITH TERMINAL DETAIL PUSH-IN STUD MATING HOLE.6 DIA [Ø.0].[8.7].050 DIA [Ø.7] TAB (Q..).0[.79].50[6.5] TAB (Q..).5[.8].09[.6].9[.5].058 DIA[Ø.7] SOLDER TYPE TABLE A TIGHTENING TORQUE SPEIFIATIONS THREAD SIZE #6- & M MOUNTING HARDWARE #8- & M THREAD TERMINAL SREW #0- & M5 THREAD TERMINAL SREW TORQUE 7-9 IN-LBS [ NM] -5 IN-LBS [.-.7 NM] 5-0 IN-LB [.7-. NM] MID TRIP ON I O SEE TABLE B DEPTH BEHIND PANEL.60 [.66] REF.0 [.8] TYP.0 [5.59] TYP (NETZ).560 [9.6] (LAST) M5 STUD.96[9.7].50 [.9] PUSH-IN STUD MAIN SHUNT, RELAY & DUAL OIL AUX. SWITH* TABLE B TERMINAL DESRIPTION TAB (Q..) SREW TYPE TAB (Q..) SREW #8- W/UPTURNED LUGS.09 TAB (Q..).0 TAB (Q..) SOLDER TYPE DEPTH BEHIND PANEL.000 [50.80].0 [5.60].07 [56.0].6 [60.05].095 [5.0].89 [55.60].970 [50.00] * AVAILABLE ON SERIES TRIP AND SWITH ONLY IRUITS. WHEN ALLED FOR ON MULTI-POLE UNITS, ONLY ONE AUX. SWITH IS RMALLY SUPPLIED, AS SHOWN IN MULTI-POLE IDENTIFIATION SHEME. SEE PAGE All dimensions are in inches [millimeters]. Tolerance ±.05 [.8] unless otherwise specified.

44 A-Series Handle Form & Fit Drawings #6- [M] THREAD X.95 [.95] DEEP PLS PER POLE.60 [5.9].0 [.0] SEE TE.60 [.66] TYP ON -POLE (AA).660 [.6] TYP.590 DIA [Ø.99].000 [50.80] TYP [9.6] TYP.70 [.].755 [9.8] MAX.690 [7.50].000 [50.80].50[6.5].0 [5.6] SHORT HANDLE TAB (Q..) TYPE SREW TYPE TAB (Q..) TYPE TERMINALS IN SERIES TRIP IRUIT ONFIGURATION SHOWN. FOR OTHER ONFIGURATIONS, SEE IRUIT AND TERMINAL DIAGRAMS. TYPIAL - OPTIONAL "ON-" LEGEND -POLE (AA) -POLE (AB).750 [9.05].55 [8.8] MAX.55 [8.8] MAX -POLE (AA) -POLE (AB).65 [57.5] MAX.750 [9.05] TYP.65 [57.5] MAX MULTI-POLE HANDLE TIE KIT SHIPPED BULK -POLE (AA) -POLE (AB).750 [9.05] TYP.05 [76.58] MAX.05 [76.58] MAX.56 DIA [Ø.96] PLS TYP PER POLE [+.5] [-.00].60 DIA [Ø6.00] ONE PER POLE.660 [.6].050 [6.67].750 [9.05] TYP PER POLE AA, AB, AB AA, AB AA AA PANEL UTOUT DETAIL TOLERANES ±.005 [±.] UNLESS OTHERWISE SPEIFIED All dimensions are in inches [millimeters]. Tolerance ±.00 [.5] unless otherwise specified. For agency code P =.50 [.8].

45 A-Series Handle Front Panel Snap-In Mounting Style 5.5 [.8].60 [.66] TYP.560 [9.6] TYP.755 [9.8] MAX BREAKER WIDTH ON POLE (AA).598 [65.99] TYP [50.80] TYP.0 [.00] TYP.7 [8.90].50[6.5].000 [50.80] (SHORT HANDLE).690 [7.50].0 [5.6].50 TAB (Q..) TYPE SREW TYPE TAB (Q..) TYPE TERMINALS IN SERIES TRIP IRUIT ONFIGURATION SHOWN. FOR OTHER ONFIGURATIONS, SEE IRUIT AND TERMINAL DIAGRAMS. POLE (AA) POLE (AB) ±.00 [±.5].00 [76.96] ±.00 [±.5].80 [57.9] ±.00 [±.5].50 [8.86] ±.00 [±.5].770 [9.56].88 [7.80].88 [7.80] ±.0 [±.0].87 [55.55] TYP POLE (AA) POLE (AB) AA AA, AB AA, AB AA, AB. [56.69]. [56.69] PANEL UTOUT DETAIL POLE (AA) POLE (AB).976 [75.59].976 [75.59] MULTI-POLE HANDLE TIE KIT SHIPPED BULK All dimensions are in inches [millimeters]. Recommended panel thickness:.00 [.0] to.00 [.5]. Tolerance ±.05 [.8] unless otherwise specified.

46 A-Series Handle Front Panel Snap-In Mounting Style 7.5 [.8] ON.60 [.66] TYP.560 [9.6] TYP.755 [9.8] MAX BREAKER WIDTH POLE (AA).598 [65.99] TYP 60.0 [.00] TYP.000 [50.80] TYP.960 [.8].50[6.5].000 [50.80] (SHORT HANDLE).690 [7.50].0 [5.6].50 TAB (Q..) TYPE SREW TYPE TAB (Q..) TYPE TERMINALS IN SERIES TRIP IRUIT ONFIGURATION SHOWN. FOR OTHER ONFIGURATIONS, SEE IRUIT AND TERMINAL DIAGRAMS. ±.00 [±.5].00 [76.96] POLE (AA) POLE (AB) ±.00 [±.5].770 [9.56] ±.00 [±.5].80 [57.9] ±.00 [±.5].50 [8.86].700 [.8].700 [.8] ±.0 [±.0].87 [55.55] TYP POLE (AA) POLE (AB) AA AA, AB AA, AB AA, AB.50 [6.].50 [6.] PANEL UTOUT DETAIL POLE (AA) POLE (AB).90 [8.0].90 [8.0] MULTI-POLE HANDLE TIE KIT SHIPPED BULK All dimensions are in inches [millimeters]. Recommended panel thickness:.00 [.0] to.00 [.5]. Tolerance ±.05 [.8] unless otherwise specified.

47 A-Series Rocker ircuit & Terminal Diagrams TERMINALS IRUIT BREAKER PROFILE IRUIT SHEMATI ANSI IE SWITH ONLY ( OIL) (NETZ) IRUIT ODE AUX SWITH ODE IRUIT SHEMATI ANSI IE SERIES TRIP (NETZ) () IRUIT ODE AUX SWITH ODE MAIN TERMINALS (SEE TABLE A) A 0 B 0 I > 5 TERMINALS.60 [.66].00 [.5] TYP.50[.] (LAST) SWITH ONLY ( OIL) () WITH AUXILIARY SWITH (LAST) SERIES TRIP WITH () AUXILIARY SWITH (NETZ) (NETZ) () N AUX. SWITH TERMINALS N ALARM SWITH TERMINALS & STD. AUX. SW. WITH VDE OR >0 AMPS N N A N I > N B TERMINALS.05 [5.] SHUNT TRIP (LAST) (NETZ) () (LAST) DUAL OIL; SERIES TRIP URRENT OIL, SHUNT TRIP VOLTAGE OIL (NETZ).90[9.9] SHUNT SHUNT (NEBENSHLUSS) I > DE 0 VOLTAGE OIL I > U > H 0 TERMINALS.780[9.8].90[9.9] RELAY RELAY (LAST) RELAY TRIP RELAY (RELAIS) I > () (NETZ) RELAY (RELAIS) (LAST) FG 0 VOLTAGE (LAST) OIL DUAL OIL; SERIES TRIP URRENT OIL, RELAY TRIP VOLTAGE OIL VOLTAGE (NETZ) OIL VOLTAGE OIL I > (LAST) U > VOLTAGE OIL K 0 SEE TABLE B DEPTH BEHIND PANEL.70[9.0]REF.60[.66] REF.0[.8] TYP.0[5.59] TYP (NETZ).560[9.6].96 [9.7].50 [.9] SHUNT, RELAY & DUAL OIL (LAST) +.00 [+.05] [-.00].6 DIA [Ø.0] M5 STUD PUSH-IN STUD TABLE B DEPTH BEHIND PANEL TERMINAL DESRIPTION MAIN TAB (Q..).70 [60.0] SREW TYPE.0 [6.0] TAB (Q..).577 [65.6] SREW #8-.7 [69.] W/UPTURNED LUGS AUX..09 TAB (Q..).65 [6.6] SWITH*.0 TAB (Q..).559 [65.00] SOLDER TYPE.0 [59.] * AVAILABLE ON SERIES TRIP AND SWITH ONLY IRUITS. WHEN ALLED FOR ON MULTI-POLE UNITS, ONLY ONE AUX. SWITH IS RMALLY SUPPLIED, AS VIEWED IN MULTI-POLE IDENTIFIATION SHEME. PUSH-IN STUD MATING HOLE All dimensions are in inches [millimeters]. Tolerance ±.05 [.8] unless otherwise specified. Schematic shown represents current trip circuit.. ircuits shown for >0 amps / VDE. 5

48 A-Series Rocker ircuit & Terminal Diagrams TERMINAL DIMENSIONAL DETAIL & RATING.60[9.].9[9.96].9[9.96].[8.7].50[6.5].069[.75] DIA.75[9.5].75[9.5].09DIA [.76].50[6.5] TAB (Q..) 0 AMP UPTURN LUG #8-0 AMP #0-0 AMP M5 0 AMP M 0 AMP BUS #8-0 AMP #0-50 AMP Q SOLDER LUG 0 AMP.000 [5.].6[9.7].60[5.9].9 [9.97] ENTER OF PUSH-IN STUD ONTAT AREA.0[.79].05[0.9].00 [.5].0 Q VOLTAGE OILS ONLY M5 STUD 50 AMP.750 [9.05] PUSH-IN STUD 50 AMP.5 [.9] DIA AUXILIARY/ALARM SWITH TERMINAL DETAIL*.[8.7].50[6.5].0[.79].050 DIA [Ø.7] TAB (Q..) TAB (Q..).5[.8].09[.6].9[.5].058 DIA[Ø.7] SOLDER TYPE TABLE A TIGHTENING TORQUE SPEIFIATIONS THREAD SIZE #6- & M MOUNTING HARDWARE #8- & M THREAD TERMINAL SREW #0- & M5 THREAD TERMINAL SREW TORQUE 7-9 IN-LBS [ NM] -5 IN-LBS [.-.7 NM] 5-0 IN-LBS [.7-. NM] All dimensions are in inches [millimeters]. Tolerance ±.05 [.8] unless otherwise specified. 6

49 A-Series Rocker Form & Fit Drawings INDIATE "ON" INDIATE "" & SINGLE OLOR (INDIATE "" SHOWN) #6- [M] THREAD X.95 [.95] DEEP PLS.95 [.00].0 [0.67].0 [.05].755 [9.8] MAX BREAKER WIDTH OPTIONAL "ROKER GUARD".660 [.6].56 [5.76].5 [.6].560 [9.6].000 [50.80].75 [8.9] MAX ROKER ADAPTER BRAKET WIDTH A.08 [5.7].70 [9.0] REF.60 [.66].70 [60.0] TAB TYPE.0 [6.0] SREW TYPE. [0.97] TAB (Q..) TYPE TERMINALS IN SERIES TRIP IRUIT ONFIGURATION SHOWN. FOR OTHER ONFIGURATIONS SEE IRUIT & TERMINAL DIAGRAMS AF. [0.97] ENTER- OF ROKER, & PANEL UT-OUT.55 [.6].95 [.00] OPTIONAL "PUSH-TO RESET" ATUATOR.5 [.6] ON I.09 [59.65].7 [5.8] A.0 [5.59] TYP OPTIONAL "ROKER GUARD" SHOWN IN DASHED S PANEL UT-OUT DETAIL +.00 [±.5] [±.00].750 [9.05] AF.055 x.05 SLOTTED HOLE (ROKER ATUATION).0 [.8] ROKER SHROUDED ON "" POSITION SIDE, SHOWN IN DASHED S.00 [5.65].660 [.] TYP ±.005 [±.].60 [.00].660 [.6].660 [.6] TYP.55 [8.8] MAX.750 [9.05] TYP.00 [5.08] ±.005 [±.].56 DIA [Ø.96] HOLES A AF.65 [57.5] MAX P() P() P() (SEE TE ) REAR VIEW OF INDIATE "ON" SERIES TRIP W/ AUX SWITH IRUIT ONFIGURATION. P() P() P() (SEE TE ) REAR VIEW OF INDIATE "" SERIES TRIP W/ AUX SWITH IRUIT ONFIGURATION. Dimensions apply to all variations shown. Notice that circuit breaker line & load terminal orientation on indicate is opposite of indicate ON. For pole orientation with horizontal legend, rotate front view clockwise 90. All dimensions are in inches [millimeters]. Tolerance ±.00 [.5] unless otherwise specified. 7

50 A-Series P Terminal Diagrams A-SERIES ROKER.5 [.7] TYP.75 [.07]. [5.90].75 [9.5] TYP.096 [.] ( PL).70 [9.0] REF.0 [.05].60 [.66].50 [.].5 [.68] PL. [5.6].09 [58.65].5 [.6].558 [9.57].000 [50.80] N.050 DIA [Ø.7] ( PL).75 [8.9] MAX.00 [5.65].07 [.9] FIBRE.0 [0.67] ± [.76] TYP.6 [6.05] PL.755 [9.8] MAX BREAKER WIDTH A-SERIES HANDLE.05 [.667]. [5.90].5 [.7] TYP.75 [9.5] TYP.096 [.] ( PL).69 [7.50].60 [.66].50 [.]. [5.6].050DIA [Ø.7] ( PL).590 DIA [Ø.99].558 [9.57].000 [50.80] ON.75 [8.9] MAX.0 [.0] ± [.76] TYP.6 [6.05].755 [9.8] MAX BREAKER WIDTH.096 [.]( PL).096 [.] ( PL). [5.90].5 [.8].060 DIA [Ø.5] THRU HOLES. [5.90].5 [.8].050 [.7].060 DIA [Ø.5] 7 THRU HOLES.58 [8.8].00 [.5] TYP.95[7.9].95[7.9].58 [8.8].00 [.5] TYP P.. FOOT PRINT P.. FOOT PRINT WITH AUX. SWITH Drawing illustrates A-Series with VDE certification. All dimensions are in inches [millimeters]. Tolerance ±.00 [.5] unless otherwise specified. 8

51 B-Series General Specifications Designed specifically for world market applications, the B-series utilizes the hydraulic magnetic principle which provides precise operation and performance even when exposed to extremely hot and/or cold application environments. Typical applications include power supplies, medical equipment, office equipment, control panels and marine equipment. -6 poles, amps, up to 77 VA or 80 VD, with choice of time delays, terminals and actuator colors. Agency ertifications UL Recognized UL Standard 077 UL Standard 508 UL Standard 500 omponent Recognition Program as Protectors, Supplementary (Guide N/QVNU, File E75596) Switches, Industrial ontrol (Guide N/NRNT, File E868) Protectors, Supplementary for Marine Electrical & Fuel Systems (Guide PEQZ, File E75596) Ignition Protection UL Listed UL Standard 89A SA ertified VDE ertified ommunications Equipment (Guide N/DITT, File E8995) omponent Supplementary Protector under lass 5 0, FIle SA Standard. No. 5 EN609, VDE 06 under File No. 057 Electrical Table A: Lists UL Recognized & SA ertified configurations and performance capabilities as a omponent Supplementary Protector. B-SERIES TABLE A: OMPONENT SUPPLEMENTARY PROTETOR VOLTAGE URRENT RATING INTERRUPTING APAITY(AMPS) FULL GENERAL UL / SA IRUIT MAX PURPOSE WITH WITHOUT ONFIGURATION RATING FREQUENY PHASE AMPS AMPS BAKUP FUSE BAKUP FUSE 65 D D D /50 50/ /50 50/ SERIES 50 50/ / / DUAL OIL SHUNT RELAY SWITH ONLY 50 50/ / D /60 & /60 & / D /60 & /60 & / D /60 & /60 & / D D / / / / Notes for Table A: Requires branch circuit backup with a UL LISTED Type K5 or RK5 fuse (5A minimum) at no more than times the rating of the protector. Same as note, except that backup fuse is limited to 80 A maximum. pole protector required (with one pole per power line) for: 50/5 VA, 5/50 VA and 08Y/0 VA Power Systems. pole protector required for : 5 VA, Ø Power System. 9

52 B-Series General Specifications Electrical Table B: Lists UL Recognized, SA, VDE & TUV ertified configurations & performance capabilities as a omponent Supplementary Protector. B-SERIES TABLE B: OMPONENT SUPPLEMENTARY PROTETOR VOLTAGE URRENT RATING INTERRUPTING APAITY (AMPS) FULL GENERAL UL / SA VDE TUV IRUIT MAX PURPOSE WITH WITHOUT (Inc) WITH (Icn) WITHOUT (Inc) WITH (Icn) WITHOUT ONFIGURATION RATING FREQUENY PHASE AMPS AMPS BAKUP FUSE BAKUP FUSE BAKUP FUSE BAKUP FUSE BAKUP FUSE BAKUP FUSE SERIES DUAL OIL SHUNT 80 D D D /60 & /60 & / / / D /60 & /60 & / D /60 & /60 & / Notes for Table B: General Purpose Ratings for UL/SA Only. Requires branch circuit backup with a UL LISTED Type K5 or RK5 fuse (5A minimum) at no more than times the rating of the protector. Same as note, except that backup fuse is limited to 80 A maximum. Table : Lists UL Recognized, SA ertified configurations and performance capabilities as Protectors, Supplementary for Marine Electrical and Fuel Systems (N/Guide PEQZ, File E75596). Ignition Protected per UL 500. UL lassified Small raft Electrical Devices, Marine in accordance with ISO 886 (N/Guide UZMK, File MQ55) as Marine Supplementary Protectors. B-SERIES TABLE : UL500 (MARINE IGNITION PROTETED) INTERRUPTING VOLTAGE URRENT APAITY RATING (AMPS) IRUIT MAX FULL WITHOUT ONFIGURATION RATING FREQUENY PHASE AMPS BAKUP FUSE D SERIES 65 D / 50 50/ / Notes for Table : Available with special catalog number only (consult factory). pole protector required (with one pole per power line) for: 50/5 VA, 5/50 VA and 08Y/0 VA Power Systems. pole protector required for : 5 VA, Ø Power System. Table D: Lists UL Listed configurations and performance capabilities as ircuit Breakers for use in ommunications Equipment (N/Guide DITT, File E8995), under UL89A B-SERIES TABLE D: UL89A LISTED (OMMUNIATIONS EQUIPMENT) INTERRUPTING VOLTAGE URRENT APAITY RATING (AMPS) IRUIT MAX UL GENERAL WITHOUT ONFIGURATION RATING FREQUENY PHASE PURPOSE AMPS BAKUP FUSE SERIES 80 D

53 B-Series General Specifications Electrical Mechanical Maximum Voltage 77VA 50/60 Hz, 80VD urrent Ratings Standard current coils: 0.00, 0.50, 0.500, 0.750,.00,.50, 5.00, 7.50, 0.0, 5.0, 0.0, 5.0, 0.0, 5.0, 0.0 and 50.0 amps. Other ratings available, see ordering scheme. Standard Voltage oils D - 6V, V; A - 0V, other ratings available, see ordering scheme. Auxiliary Switch Rating SPDT; 0. AMPS - 50VA,.0A 65 VD or 0.5A 80 VD, 0. Amps - 5VA (with gold contacts). VDE-.0 Amp - 5VA. Insulation Resistance Minimum of 00 Megohms at 500 VD. Dielectric Strength UL, SA V 50/60 Hz for one minute between all electrically isolated terminals. B-Series circuit breakers comply with the 8mm spacing and 750V 50/60 Hz dielectric requirements from hazardous voltage to operator accessible surfaces, between adjacent poles and from main circuits to auxiliary circuits per Publications EN and VDE Resistance, Impedance Values from Line to Load Terminal - based on Series Trip ircuit Breaker. O H M S RESISTANE, IMPEDANE VALUES from Line to Load Terminals (Values Based on Series Trip ircuit Breaker) Pulse Tolerance urves Multiple of Rated urrent 5x x I r AMPERE RATING 60 Hz / ycle Inrush Pulse Tolerance Time Delay urves, & 6 (50 Amps Max.) Time Delay urves,, 6,,, 6 (70 Amps Max.) Multiple of Rated urrent x 0x I r URRENT TOLERANE (AMPS) (%) ± 5% ± 5% ± 5% y Inrush Pulse Tolerance Time Delay urves, & 6 (50 Amps Max.) Time Delay urves,, 6,,, 6 (70 Amps Max.) Endurance Trip Free Trip Indication Physical 0,000 ON- 6 per minute; with rated urrent and Voltage. All B-Series ircuit Breakers will trip on overload, even when Handle is forcibly held in the ON position. The operating Handle moves positively to the position when an overload causes the breaker to trip. Number of Poles - 6 poles at 0 Amps or less. and poles at Amps thru 50 Amps. Internal ircuit onfig. Series, (with or without auxiliary switch), Shunt and Relay with current or voltage trip coils, Dual oil, Switch Only (with or without auxiliary switch). Weight Approximately 65 grams/pole. (Approximately. ounces/pole. Standard olors Housing- Black; Actuator - See Ordering Scheme. Environmental Designed and tested in accordance with requirements of specification MIL-PRF and MIL-STD-0 as follows: Shock Withstands 00 Gs, 6ms, sawtooth while carrying rated current per Method, Test ondition "I". Instantaneous and ultra-short curves 90% of rated current. Vibration Withstands 0.060" excursion from 0-55 Hz, and 0 Gs Hz, at rated current per Method 0, Test ondition A. Instantaneous and ultrashort curves tested at 90% of rated current. Moisture Resistance Method 06D, i.e., ten -hour + 5 to +65, 80-98% RH. Salt Spray Method 0, ondition A (90-95% 5% Nal Solution, 96 hrs). Thermal Shock Method 07D, ondition A (Five -55 to +5 to +85 to +5 ). t t Time in Milliseconds Time in Milliseconds 5

54 B Series 5 Aux/Alarm Switch B-Series Handle UL Recognized Ordering Scheme A B B Actuator Poles ircuit 6 Frequency & Delay 7 urrent Rating 8 Terminal 9 Actuator olor 0 Mounting/ Barriers Agency Approval SERIES B ATUATOR A Handle, one per pole B Handle, one per multipole unit S Mid-Trip Handle, one per pole T Mid-Trip Handle, one per pole & Alarm Switch POLES One Two IRUIT A Switch Only (No oil) B Series Trip (urrent) Series Trip (Voltage) D Shunt Trip (urrent) E Shunt Trip (Voltage) Relay Trip (urrent) F 5 AUXILIARY/ALARM SWITH 5 0 w/o Aux Switch S.P.D.T., 0.09 Q.. Term. S.P.D.T., 0.0 Q.. Term. S.P.D.T., 0.9 Solder Lug S.P.D.T., 0.0 Q.. Term. (Gold ontacts) 6 FREQUENY & DELAY 0 D 50/60Hz, Switch Only 0 6 D Instantaneous D Ultra Short D Short D Medium 6 D Long /60Hz Instantaneous 50/60Hz Ultra Short 50/60Hz Short 50/60Hz Medium 6 50/60Hz Long Three Four G H, J, K, 5 Five 6 Six Relay Trip (Voltage) Dual oil with Shunt Trip Voltage oil Dual oil with Shunt Trip Voltage oil (side terminal) Dual oil with Relay Trip Voltage oil 5 S.P.S.T., 0.09 Q.. Term.(Gold ontacts) 6 S.P.S.T., 0.9 Solder Lug 7 S.P.S.T., 0.0 Q.. Term.(Gold ontacts) 8 S.P.S.T., 0.87 Q.. Term. 9 S.P.D.T., 0.87 Q.. Term. 0 D, 50/60Hz Instantaneous D, 50/60Hz Ultra Short D, 50/60Hz Short D, 50/60Hz Medium 6 D, 50/60Hz Long 7 50/60Hz Short, Hi-Inrush 7 50/60Hz Medium, Hi-Inrush /60Hz Long, Hi-Inrush 5 7 D, Short,Hi-Inrush 5 7 D,Medium, Hi-Inrush 56 7 D, Long, Hi-Inrush Actuator ode: A: Handle tie pin spacer(s) and retainers provided unassembled with multi-pole units. B: Handle location as viewed from front of breaker: pole - left pole pole - center pole pole - two handles at center poles 5 pole - three handles at center poles 6 pole - four handles at center poles S: Handle moves to mid-position only upon electrical trip of the breaker. Available with circuit codes B,, D, E, F, G, H and K. T: Handle moves to mid-position and alarm switch activates only upon electrical trip of the breaker. Available with circuit codes B &. Switch Only circuits, rated up to 50 amps and 6 poles, and only available with VDE ertification when tied to a protected pole (ircuit ode B,, D or H.), For.0 to 0 amps, select urrent ode 60. For 5-50 amps, select urrent ode 650. Available with Terminal odes, and. urrent Rating limited to 0 amps maximum. onsult factory for available Dual oil options, as special catalog number is required. With Shunt construction, Dual oils will trip instantaneously on line voltage. Dual coils require 0VA minimum power to trip and are rated for intermittent duty only. 5 Auxiliary Switch breakers with Series Trip and Switch Only circuits. On multi-pole breakers, one aux. switch is supplied, mounted in the extreme right pole. 6 Separate pole type voltage coils not rated for continuous duty. Available only with delay codes 0 and 0. 7 Available with ircuit odes B & D only. VDE ertified to 0 amps. UL Recognized and SA ertified to 50 amps. 8 VDE ertification available with single pole breakers with D Delay only. UL Recognition and SA ertification available in one and two pole breakers. 9 Screw Terminals are recommended on ratings greater than 0 amps. Ratings over 0 amps are only available with Terminal odes 5, 9, G, H, M and Q. 0 VDE ertification up to 5 amps and UL Recognition and SA ertification up to 0 amps, but not recommended over 0 amps. Terminal odes, 5 E and H (Bus Type) with VDE, are supplied with Lock Washers, and Terminal ode M (M6 Threaded Stud) with VDE is supplied with Lock and Flat Washers. These breakers are only VDE ertified when the washers are used. VDE ert. available up to amps. UL Rec. & SA ert. available up to 0 amps. Single pole breakers with Terminal ode P (Printed ircuit Board) are available up to 0 amps with VDE ertification and 50 amps with UL Recognition and SA ertification, with ircuit odes A, B and. Two pole breakers with Terminal ode P (Printed ircuit Board) are available up to 0 amps with UL Recognition and SA ertification with ircuit odes A, B and. Available with Actuator odes A, S and T. 5 Available with voltage coils only. 5 7 URRENT RATING (AMPERES) TERMINAL 9 0 Push-On 0.50 Tab (Q..) Screw 8- w/upturned lugs Screw 8- (Bus Type) Screw 0- w/upturned lugs 5 Screw 0- (Bus Type) 6 Screw 8- w/upturned lugs and 0 bend 7 Screw 8- (Bus Type) and 0 bend 8 Screw 0- w/upturned lugs and 0 bend 9 Screw 0- (Bus Type) and 0 bend B Screw M5 w/upturned lugs Screw M w/upturned lugs OR VOLTAGE OIL (MINAL RATED VOLTAGE) 6 A06 6 D A D J A A D A8 8 D J8 8 A A8 8 D A65 65 D J A A D J06 6 A J8 8 A MOUNTING/BARRIERS MOUNTING STYLE BARRIERS Threaded Insert, per pole 6- x 0.95 inches no A 6- X 0.95 inches yes ISO M x 5mm no B ISO M x 5mm yes Rectangular Adapter Plate with mounting centers of.06 [5.7mm] and Threaded insert, per pole 6- x 0.5 inches no 6- X 0.5 inches yes ISO M x 6.5mm no D ISO M x 6.5mm yes Front panel Snap-In, 0.75 [9.05mm] wide bezel 5 without Handleguard no 6 without Handleguard yes Front panel Snap-In, 0.96 [.8mm] wide bezel 7 without Handleguard on -pole units;.05 [.67mm] ] no bezel overhang/ side on multipole units 8 without Handleguard on -pole units;.05 [.67mm] yes bezel overhang/side on multipole units AGENY APPROVAL UL Recognized & SAertified D VDE ertified, UL Recognized & SAertified E TUV ertified, UL Recognized & SAertified I UL Rec. STD 077, UL Rec. 500 (ignition protected), & SAertified E F G H L M P Q R 9 ATUATOR OLOR & LEGEND I-O ON- Dual Legend olor White A B Black Black D White Red F G White Green H J White Blue K L 5 White Yellow M N 6 Black Gray P Q 7 Black Orange R S 8 Black S 5 T J65 K0 L0 65 A 0 A 0 A Screw M (Bus Type) Screw M5 w/upturned lugs and 0 bend Screw M5 (Bus Type) and 0 bend Screw M5 (Bus Type) 0.50 Q../ Solder Lug M6 Threaded Studs Printed ircuit Board Terminals Push-In Stud Screw M w/upturned lugs and 0 bend Push-On 0.0 Tab (Q..) Screw M (Bus Type) and 0 bend

55 B-Series Handle UL89A Ordering Scheme B Series A B 0 50 B M Actuator Poles ircuit 5 Aux/Alarm Switch 6 Frequency & Delay 7 urrent Rating 8 Terminal 9 Actuator olor 0 Mounting/ Barriers Max. Appl. Rating T Agency Approval SERIES B ATUATOR A Handle, one per pole S Mid-Trip Handle, one per pole T Mid-Trip Handle, one per pole & Alarm Switch POLES One Two Three Four IRUIT B Series Trip (urrent) 5 AUXILIARY/ALARM SWITH 0 w/o Aux Switch S.P.D.T., 0.09 Q.. Term. S.P.D.T., 0.0 Q.. Term. S.P.D.T., 0.9 Solder Lug 6 FREQUENY & DELAY D Ultra Short D Short D Medium 6 D Long 7 URRENT RATING (AMPERES) S.P.S.T., 0.0 Q.. Term.(Gold ontacts) 8 S.P.S.T., 0.87 Q.. Term. 9 S.P.D.T., 0.87 Q.. Term. 5 D, Short,Hi-Inrush 5 D, Medium, Hi-Inrush 56 D, Long, Hi-Inrush Actuator ode: A: Handle tie pin spacer(s) and retainers provided unassembled with multi-pole units. S: Handle moves to mid-position only upon electrical trip of the breaker. T: Handle moves to mid-position and alarm switch activates only upon electrical trip of the breaker. On multi-pole breakers, one auxiliary switch is supplied, mounted in the extreme right pole. VDE ertified to 0 amps. UL89A Listed to 50 amps. VDE ertification available with single pole breakers only. UL89A Listing available with one and two pole breakers. 5 Screw Terminals are recommended on ratings greater than 0 amps. Ratings over 0 amps are only available with Terminal odes 5, 9, G, H, M and Q. 6 Terminal ode (Push-On) available up to 5 amps with VDE ertification and 0 amps with UL89A Listing, but is not recommended over 0 amps. 7 Terminal odes, 5 and H (Bus Type) with VDE, are supplied with Lock Washers, and Terminal ode M (M6 Threaded Stud) with VDE is supplied with Lock and Flat Washers. These breakers are only VDE ertified when the washers are used. 8 Single pole breakers with Terminal ode P (Printed ircuit Board) are available up to 0 amps with VDE ertification and 50 amps with UL89A Listing. 8 TERMINAL 5 6 Push-On 0.50 Tab (Q..) Screw 8- w/upturned lugs 7 Screw 8- (Bus Type) Screw 0- w/upturned lugs 5 7 Screw 0- (Bus Type) 6 Screw 8- w/upturned lugs and 0 bend 7 Screw 8- (Bus Type) and 0 bend 8 Screw 0- w/upturned lugs and 0 bend 9 ATUATOR OLOR LEGEND ON- Dual Legend olor White B Black Black D White Red G White Green J White Blue L 5 White Yellow N 6 Black Gray Q 7 Black Orange S 8 Black 9 Screw 0- (Bus Type) and 0 bend B Screw M5 w/upturned lugs F Screw M5 w/upturned lugs and 0 bend G Screw M5 (Bus Type) and 0 bend H Screw M5 (Bus Type) M 7 M6 Threaded Stud P 8 Printed ircuit Board Terminals Q Push-In Stud 0 MOUNTING/BARRIERS MOUNTING STYLE BARRIERS Threaded Insert, per pole 6- x 0.95 inches no A 6- X 0.95 inches yes ISO M x 5mm no B ISO M x 5mm yes Rectangular Adapter Plate with mounting centers of.06 inches and Threaded insert, per pole 6- x 0.5 inches no 6- X 0.5 inches yes ISO M x 6.5mm no D ISO M x 6.5mm yes Front panel Snap-In, 0.75 wide bezel 5 without Handleguard no 6 without Handleguard yes Front panel Snap-In, 0.96 wide bezel 7 without Handleguard on -pole no units;.05 bezel overhang/ side on multipole units 8 without Handleguard on -pole yes units;.05 bezel overhang/ side on multipole units MAXIMUM APPLIATION RATING M 80 D AGENY APPROVAL T UL89A LISTED K UL89A LISTED, VDE ERTIFIED 5

56 B-Series Handle ircuit & Terminal Diagrams SERIES TRIP ( TERM'S.) ANSI IRUIT SHEMATI SWITH ONLY ( OIL) IE (NETZ) IRUIT ODE AUX SWITH ODE IRUIT SHEMATI ANSI SERIES TRIP IE () (NETZ) IRUIT ODE AUX SWITH ODE MAIN TERM'S. (SEE TABLE A) A O B O I > SERIES TRIP W AUX SWITH (5 TERM'S.).70 [.9].50 [.] SWITH ONLY ( OIL) WITH AUXILIARY SWITH (LAST) (NETZ) SERIES TRIP WITH AUXILIARY / ALARM SWITH STD. AUX. SWITH (LAST) (NETZ) () STD. AUX. SWITH N A B AUX. SWITH TERM'S. N N (LAST) N ALARM SWITH I > N ALARM SWITH (LAST) SHUNT TRIP ( TERM'S.) SHUNT TRIP (NETZ) () DUAL OIL; SERIES TRIP URRENT OIL, SHUNT TRIP VOLTAGE OIL (NETZ) SHUNT SHUNT (NEBENSHLUSS) D E 0 H 0 I > VOLTAGE OIL I > U > RELAY TRIP ( TERM'S.).90 [9.9].780 [9.8].90 [9.9] RELAY RELAY RELAY TRIP (LAST) RELAY (RELAIS) I > RELAY (RELAIS) (NETZ) (LAST) () F G 0 VOLTAGE OIL (LAST) DUAL OIL; SERIES TRIP URRENT OIL, RELAY TRIP VOLTAGE OIL (NETZ) I > (LAST) VOLTAGE OIL VOLTAGE OIL U > VOLTAGE OIL K 0 All dimensions are in inches [millimeters]. Tolerance ±.05 [.8] unless otherwise specified. Alarm Switch available with.0 x.00 Q.. & Solder Lug Terminals Only. 5

57 +.00 [+.05] [-.00] arling B-Series Handle ircuit & Terminal Diagrams HANDLE POSITION VS. AUX/ALARM SWITH MODE IRUIT BREAKER MODE STANDARD /B HANDLE POSITION AUX. SWITH MODE HANDLE POSITION MID TRIP /B ALARM SWITH MODE 0 0 O N O N ON ON I I ON 0 N 0 N ELETRIAL TRIP 0 90 MID TRIP O N N TERMINAL DIMENSIONAL DETAIL & RATING.000 [5.].60[9.].9[9.96].9[9.96].[8.7].6[9.7].60[5.9].9 [9.97] ENTER OF PUSH-IN STUD ONTAT AREA.50[6.5].069[.75] DIA TAB (Q..) 0 AMP.75[9.5] UPTURN LUG #8-0 AMP #0-0 AMP M5 0 AMP M 0 AMP.75[9.5].50[6.5].09DIA [.76] BUS Q SOLDER LUG #8-0 AMP 0 AMP #0-50 AMP.0[.79].0 Q M5 STUD VOLTAGE OILS 50 AMP ONLY.05[0.9].00 [.5].750 [9.05] PUSH-IN STUD 50 AMP.5 [.9] DIA PUSH-IN STUD MATING HOLE.6 DIA [Ø.0] AUXILIARY SWITH TERMINAL DETAIL.0 [.80].0 [.80].05 DIA[Ø.9].087 [.0].87 [7.9].6 [.0].070 DIA [Ø.80] TAB (Q..) SOLDER TYPE TABLE A TIGHTENING TORQUE SPEIFIATIONS THREAD SIZE TORQUE #6- & M MOUNTING 7-9 IN-LBS HARDWARE [ NM] #8- & M THREAD -5 IN-LBS TERMINAL SREW [.-.7 NM] #0- & M5 THREAD 5-0 IN-LBS TERMINAL SREW [.7-. NM] MID TRIP ON I O SEE TABLE-B DEPTH BEHIND PANEL (NETZ).560 [9.6] TYP (LAST).0 [.8] TYP.0 [5.59] TYP M5 STUD.96[9.7].50 [.9] PUSH-IN STUD TABLE B TERMINAL DESRIPTION TAB (Q..) MAIN SREW TYPE SHUNT, RELAY TAB (Q..) & SREW #8- DUAL OIL W/UPTURNED LUGS TAB (Q..).0 x.00 AUX. SWITH* SOLDER TYPE DEPTH BEHIND PANEL.090 [5.09]. [5.90].6 [66.5].6 [67.6].57 [6.].8 [59.6] * AVAILABLE ON SERIES TRIP AND SWITH ONLY IRUITS. WHEN ALLED FOR ON MULTI-POLE UNITS, ONLY ONE AUX. SWITH IS RMALLY SUPPLIED, AS SHOWN IN MULTI-POLE IDENTIFIATION SHEME. All dimensions are in inches [millimeters]. Tolerance ±.05 [.8] unless otherwise specified. 55

58 B-Series Handle Form & Fit Drawings #6- [M] THREAD X.95 [.95] DEEP PLS PER POLE.0 [6.0].70 [.9] TYP ON I -POLE (BA).60 [5.9].660 [.6] TYP.00 [50.80] TYP 60 I.560 [9.6] TYP.755 [9.8] MAX.70 [.].590 DIA [Ø.99].690 [7.50].090 [5.09]. [5.89].50 TAB (Q..) TYPE SREW TYPE TAB (Q..) TYPE TERMINALS IN SERIES TRIP IRUIT ONFIGURATION SHOWN. FOR OTHER ONFIGURATIONS, SEE IRUIT AND TERMINAL DRAWINGS. -POLE (BA) TYPIAL-OPTIONAL "I-O" OR "ON-" LEGEND -POLE (BB).750 [9.05].55 [8.8] MAX.55 [8.8] MAX -POLE (BA) -POLE (BB).65 [57.5] MAX.750 [9.05] TYP.65 [57.5] MAX MULTI-POLE HANDLE TIE KIT SHIPPED BULK -POLE (BA) -POLE (BB).750 [9.05] TYP.05 [76.58] MAX.05 [76.58] MAX.56 DIA [Ø.96] PLS TYP PER POLE +.00 [+.5] [-.00].60 DIA [Ø6.00] ONE PER POLE.660 [.6].050 [6.67].750 [9.05] TYP PER POLE BA, BB, BB BA, BB BA BA All dimensions are in inches [millimeters]. Tolerance ±.00 [.5] unless otherwise specified. PANEL UTOUT DETAIL TOLERANES ±.005 [±.] 56

59 B-Series Handle Front Panel Snap-In Mounting Style [7.5].70 [.9] TYP.5 [.8].755 [9.8] MAX. BREAKER WIDTH POLE (BA).598 [65.99] TYP 60 ON I O.000 [50.80] TYP.560 [9.6] TYP.0 [.00] TYP.7 [8.90].0 [6.0].090 [5.09]. [5.89].50 TAB (Q..) TYPE SREW TYPE TAB (Q..) TYPE TERMINALS IN SERIES TRIP IRUIT ONFIGURATION SHOWN. FOR OTHER ONFIGURATIONS, SEE IRUIT AND TERMINAL DIAGRAMS. TYPIAL-OPTIONAL "I-O" OR "ON-" LEGEND ±.00 [±.5].00 [76.96] POLE (BA) POLE (BB) ±.00 [±.5].80 [57.9] ±.00 [±.5].50 [8.86] ±.00 [±.5].770 [9.56].88 [7.80] ] ±.0 [±.0].87 [55.55] TYP POLE (BA) POLE (BB) BA BA, BB BA, BB. [56.69]. [56.69] BA, BB PANEL UTOUT DETAIL POLE (BA) POLE (BB).976 [75.59].976 [75.59] MULTI-POLE HANDLE TIE KIT SHIPPED BULK All dimensions are in inches [millimeters]. Recommended panel thickness:.00 [.0] to.00 [.5]. Tolerance ±.05 [.8] unless otherwise specified. 57

60 B-Series Handle Front Panel Snap-In Mounting Style 7.70 [.9] TYP.690 [7.50].5 [.8].755 [9.8] MAX BREAKER WIDTH ON I POLE (BA).598 [65.99] TYP 60 O.000 [50.80] TYP.560 [9.6] TYP.0 [.00] TYP.960 [.8].0 [6.0].090 [5.09]. [5.89].50 TAB (Q..) TYPE SREW TYPE TAB (Q..) TYPE TERMINALS IN SERIES TRIP IRUIT ONFIGURATION SHOWN. FOR OTHER ONFIGURATIONS, SEE IRUIT AND TERMINAL DIAGRAMS. TYPIAL - OPTIONAL "I - O" OR "ON-" LEGEND ±.00 [±.5].00 [76.96] POLE (BA) POLE (BB) ±.00 [±.5].80 [57.9] ±.00 [±.5].50 [8.86] ±.00 [±.5].770 [9.56].700 [.8].700 [.8] ±.0 [±.0].87 [55.55] TYP POLE (BA) POLE (BB) BA BA, BB BA, BB.50 [6.].50 [6.] BA, BB PANEL UTOUT DETAIL POLE (BA) POLE (BB).90 [8.0].90 [8.0] MULTI - POLE HANDLE TIE KIT SHIPPED BULK All dimensions are in inches [millimeters]. Recommended panel thickness.00 [.0] to.00 [.5]. Tolerance ±.05 [.8] unless otherwise specified. 58

61 B-Series P Terminal Diagrams.95 [.667]. [56.8].5 [.7] TYP.75 [9.5] TYP.590 DIA [Ø.99].050DIA [Ø.7] ( PL).70 [.9] TYP.0 [6.0]. [5.6] O.000 [50.80].096 [.] ( PL) [9.57].755 [9.8] MAX ON I.690 [7.50].7 [6.05] ± [.76] TYP.755 [9.8] MAX BREAKER WIDTH.096 [.]( PL).096 [.] ( PL). [56.8].5 [.8].060 DIA [Ø.5] THRU HOLES. [56.8].5 [.8].050 [.7].060 DIA [Ø.5] 7 THRU HOLES.58 [8.8].00 [.5] TYP.95[7.9].95[7.9].58 [8.8].00 [.5] TYP P.. FOOT PRINT P.. FOOT PRINT WITH AUX. SWITH All dimensions are in inches [millimeters]. Tolerance ±.00 [.5] unless otherwise specified. 59

62 -Series General Specifications Designed for those applications requiring higher amperage and voltage handling capability in a compact design. Available with American Standard or Metric Threaded Stud terminals, or Saddle lamp screw terminals. Available with optional mid-trip handle style actuator, solid color rocker actuators and Visi-rocker two color actuators. Visi-rocker can be specified to indicate either the ON or TRIPPED/ mode. Rockerguard and Push-To-Reset bezel help prevent inadvertent actuation. The -Series UL89 breakers employ a unique arc chute design which results in obtaining higher interrupting capacities, up to 50,000 amps. Thermoset glass filled polyester half shell construction for increased mechanical & electrical strength; Wiping ontacts - Mechanical linkage with two-step actuation cleans contacts, provides high, positive contact pressure & longer contact life; -6 poles, amps, up to 80 VA or 80 VD, UL89 up to 0 VA or 5 VD, with choice of time delays and actuator colors. Agency ertifications UL Recognized UL Standard 077 omponent Recognition Program as Protectors, Supplementary (Guide QVNU, File E75596) SA ertified omponent Supplementary Protector (lass 5 0, FIle SA Standard. No. 5) UL Standard 508 UL Standard 500 UL Listed UL Standard 89 Manual Motor ontrols (Guide NLRV, File E567) Protectors, Supplementary for Marine Electrical & Fuel Systems (Guide PEQZ, File E75596) Ignition Protection ircuit Breakers, Molded ase, (Guide DIVQ, File E9899) VDE ertified ircuit Breaker Molded ase (lass 0, File 0990), SA Standard. No M EN609, VDE 06 under File No. 057 UL Standard 89A ommunications Equipment (Guide N/DITT, File E8995) 60

63 -Series General Specifications Electrical Table A: Lists UL Recognized & SA ertified configurations and performance capabilities as a omponent Supplementary Protector. FULL GENERAL UL / SA IRUIT MAX PURPOSE WITH WITHOUT ONFIGURATION RATING FREQUENY PHASE AMPS AMPS BAKUP FUSE BAKUP FUSE SERIES DUAL OIL SHUNT RELAY SWITH ONLY VOLTAGE -SERIES TABLE A: OMPONENT SUPPLEMENTARY PROTETOR URRENT RATING INTERRUPTING APAITY (AMPS) 65 D D D , / / /50 50/ /50 50/ /50 50/ / / / / / /77 50/ / D / / D / / /77 50/ / D / / D D / /50 50/ /60 & / /77 50/ ONSTRUTION TES Must have Agency ode "L" Must have Agency ode "L" Pole or Poles Breaking Ø or Poles Breaking Ø - Poles Breaking Ø "L" Agency ode Must have Agency ode "L" Poles Breaking Ø Must have Agency ode "L" Poles breaking Ø Poles breaking Ø Poles breaking Ø Poles breaking Ø or Poles Breaking Ø Poles breaking Ø Notes for Table A: Requires branch circuit backup with a UL LISTED Type K5 or RK5 fuse rated 5A minimum and no more than times full load amps not to exceed 5A for 50 Amp or less rating and not to exceed 75 for 5 through 00 Amp rating. Table B: Lists UL Recognized and SA ertified configurations and performance capabilities as a Manual Motor ontroller. -SERIES TABLE B: MANUAL MOTOR ONTROLLER URRENT HORSEPOWER VOLTAGE RATING RATINGS IRUIT MAX FULL ONFIGURATION RATING FREQUENY PHASE AMPS MAX / HP SERIES, 80 50/ HP SHUNT & 50 50/ HP 50 50/ HP SWITH ONLY 0 50/ HP 0 50/ / HP Notes for Table B: Requires branch circuit backup with a UL LISTED Type K5 or RK5 fuse rated 5A minimum and no more than times full load amps not to exceed 5A for 50 Amp or less rating and not to exceed 75 for 5 through 00 Amp rating. UL recognized and SA ertified at 80V refers to & pole versions used in a Ø, wye connected circuit or -pole version connected with poles breaking. Ø and backed up with series fusing as stated above in note. 6

64 -Series General Specifications Electrical Table : Lists UL Recognized, SA, VDE and TUV ertified configurations and performance capabilities as a omponent Supplementary Protector. -SERIES TABLE : OMPONENT SUPPLEMENTARY PROTETOR VOLTAGE URRENT RATING INTERRUPTING APAITY (AMPS) FULL GENERAL UL / SA VDE IRUIT MAX PURPOSE WITH WITHOUT (Inc) WITH (Icn) WITHOUT ONFIGURATION RATING FREQUENY PHASE AMPS AMPS BAKUP FUSE BAKUP FUSE BAKUP FUSE BAKUP FUSE ONSTRUTION TES 80 D D , Agency ode "F" or "H" Only SERIES 50 50/60 & Y/0 50/ Rocker Actuator 5Y/0 50/ Handle Actuator/ Agency ode H only DUAL OIL 80 D /60 & D SHUNT 50 50/60 & Y/0 50/ Rocker Actuator 5Y/0 50/ Handle Actuator/ Agency ode H only Notes for Table : General Purpose ratings for UL/SA only. Requires branch circuit backup with a UL LISTED Type K5 or RK5 fuse rated 5A minimum and no more than times full load amps not to exceed 5A for 50 Amp or less rating and not to exceed 75 for 5 through 00 Amp rating. Table D: Lists UL Listed (89), SA ertified (. No. 5.-M) configuration and performance capabilities as a Molded ase ircuit Breaker. -SERIES TABLE D: UL89 LISTED BRANH IRUIT BREAKER VOLTAGE URRENT INTERRUPT RATING APAITY (AMPS) IRUIT MAX FULL WITHOUT ONFIGURATION RATING FREQUENY PHASE AMPS BAKUP FUSE ONSTRUTION TES 80 D ,000 Limited to Poles max from 7-00 Amps 80 D ,000 Limited to Poles max from 7-00 Amps 5 D ,000 - Poles SERIES 0 50 / ,000 - Poles 0 50 / ,000 or Poles 0 50 / ,000 Pole 80D/0A D-50/ ,000 or Poles 0/0 50 / ,000 or poles. Pole of a Pole Unit is Neutral DUAL OIL 0 50/ , Notes from Table D: Special catalog number required. onsult factory. Table E: Lists UL Recognized, SA ertified configurations and performance capabilities as Protectors, Supplementary for Marine Electrical and Fuel Systems (Guide PEQZ, File E75596). Ignition Protected per UL 500. UL lassified Small raft Electrical Devices, Marine in accordance with ISO 886 (Guide UZMK, File MQ55) as Marine Supplementary Protectors. -SERIES TABLE E: UL500 (MARINE IGNITION PROTETED) URRENT INTERRUPTING VOLTAGE RATING APAITY (AMPS) IRUIT MAX FULL WITHOUT ONFIGURATION RATING FREQUENY PHASE AMPS BAKUP FUSE 8 D D D SERIES 5 50/ / / ONSTRUTION TES Poles Breaking Ø Table F: Lists UL Listed configurations and performance capabilities as ircuit Breakers for use in ommunications Equipment (Guide DITT, File E8995), under UL89A. -SERIES TABLE F: PARALLEL POLE ONSTRUTION UL89A LISTED FOR OMMUNIATIONS EQUIPMENT URRENT INTERRUPTING VOLTAGE RATING APAITY (AMPS) IRUIT MAX UL GENERAL WITHOUT ONFIGURATION RATING FREQUENY PHASE PURPOSE (AMPS) BAKUP FUSE SERIES 80 D ,000 6

65 -Series General Specifications Electrical Mechanical Maximum Voltage A, 80 WYE/77 VA, 50/60 Hz (see Table A.) UL89: A,0 VA. (See Table D), 50/60 Hz, 5 VD urrent Rating Standard current coils: 0.00, 0.50, 0.500, 0.750,.00,.50, 5.00, 7.50, 0.0, 5.0, 5.0, 0.0, 5.0, 0.0, 50.0, 60.0, 70.0, 80.0, 90.0 and 00 amps. Other ratings available, see Ordering Scheme. Standard Voltage oils D - 6V, V; A - 0V; other ratings available, see Ordering Scheme. Auxiliary Switch Rating SPDT; 0. amps-50va, D Aux. Switch.0A, 65 VD. 0.5A, 80VD,/ HP, 5VA,VDE & TUV.0 5 VA. Insulation Resistance Minimum of 00 Megohms at 500 VD. Dielectric Strength UL, SA: 960 V 50/60 Hz for one minute between all electrically isolated terminals. -Series ircuit Breakers comply with the 8mm spacing and 750V 50/60 Hz dielectric requirements from hazardous voltage to operator accessible surfaces, between adjacent poles and from main circuits to auxiliary circuits per Publications EN and VDE Resistance, Impedance Values from Line to Load Terminal - based on Series Trip ircuit Breaker O H M S 0. Multiple of Rated urrent x x I r RESISTANE, IMPEDANE VALUES from Line to Load Terminals (Values Based on Series Trip ircuit Breaker ) AMPERE RATING 60 Hz / ycle Inrush Pulse Tolerance Time Delay urves 50 Hz / ycle, & 6 I Inrush Pulse Tolerance r (50 Amps Max.) Time Delay urves x, & 6 Time Delay urves (50 Amps Max.),,, (00 Amps Max.) Time Delay urves 6, 6 (70 Amps Max.) 0x,,, (00 Amps Max.) 6, 6 (70 Amps Max.) t t Multiple of Rated urrent URRENT TOLERANE (AMPS) (%) ± 5% ± 5% ± 5% Time in Milliseconds Endurance Trip Free Trip Indication Physical 0,000 ON- 6 per minute; with rated current & voltage. All -Series circuit breakers will trip on overload, even when actuator is forcibly held in the ON position. The operating actuator moves positively to the position when an overload causes the breaker to trip. With mid-trip, handle moves to the mid position on electrical trip of the circuit breaker. With mid trip handle with alarm switch, handle moves to the mid position and the alarm switch actuates when the circuit Number of Poles -6 poles 50A; A; - poles 7-00A. UL89 Handle: pole 00A, pole 50A; Rocker: pole 00A. Internal ircuit onfigurations Series (with or without auxiliary switch, mid trip & mid trip with alarm switch) Shunt & Relay with current or voltage trip coils, Dual oil, Switch Only (with or without aux. switch). UL89: Series (with or without auxiliary switch, mid-trip & mid-trip with alarm switch). Weight Approx. grams/pole (.95 oz). Standard olors Housing: Black Environmental Designed and tested in accordance with requirements of specification MIL-PRF-5569 & MIL-STD-0 as follows: Shock Withstands 00 Gs, 6ms sawtooth while carrying rated current per Method, Test ondition "I". Instantaneous and ultrashort curves 90% of rated current. Vibration Withstands 0.060" excursion from 0-55 Hz & 0 Gs rated current per Method 0, Test ond. A. Instantaneous & ultrashort curves 90% of rated current. Moisture Resistance Method 06D, i.e., ten -hour +5 to +65, 80-98% RH. Salt Spray Method 0, ondition A (90-95% 5% Nal Solution, 96 hrs). Thermal Shock Method 07D, ondition A (five -55 to +5 to +85 to 6

66 -Series Handle UL Recognized Ordering Scheme Series A B Actuator Poles ircuit 5 Aux/Alarm Switch 6 Frequency & Delay 7 urrent Rating 8 Terminal 9 Actuator olor 0 Mounting/ Barriers Agency Approval SERIES ATUATOR A Handle, one per pole B Handle, one per multipole unit S Mid-Trip Handle, one per pole T Mid-Trip Handle, one per pole & Alarm Switch POLES One Two IRUIT A Switch Only (No oil) B Series Trip (urrent) Series Trip (Voltage) D Shunt Trip (urrent) Shunt Trip (Voltage) E 5 AUXILIARY/ALARM SWITH 6 0 w/o Aux Switch S.P.D.T., 0.0 Q.. Term. S.P.D.T., 0.9 Solder Lug S.P.D.T., 0.0 Q.. Term. (Gold ontacts) Three Four F G H,5 K,5 5 Five 6 Six Relay Trip (urrent) Relay Trip (Voltage) Dual oil with Shunt Trip Voltage oil Dual oil with Relay Trip Voltage oil 5 S.P.S.T., 0.0 Q.. Term. (Gold ontacts) 6 S.P.S.T., 0.9 Solder Lug 7 S.P.S.T., 0.0 Q.. Term.(Gold ontacts) 8 S.P.S.T., 0.87 Q.. Term. 9 S.P.D.T., 0.87 Q.. Term. 7 URRENT RATING (AMPERES) OR VOLTAGE OIL (MINAL RATED VOLTAGE) 7 A06 6 D A D J A A D A8 8 D J8 8 A A8 8 D A65 65 D J A A D J06 6 A J8 8 A J65 K0 L0 65 A 0 A 0 A 6 FREQUENY & DELAY 0 D 50/60Hz, Switch Only 0 7 D Instantaneous D Ultra Short D Short D Medium 6 D Long /60Hz Instantaneous 50/60Hz Ultra Short 50/60Hz Short 50/60Hz Medium 6 50/60Hz Long 0 D, 50/60Hz Instantaneous D, 50/60Hz Ultra Short D, 50/60Hz Short D, 50/60Hz Medium 6 D, 50/60Hz Long 8 50/60Hz Short, Hi-Inrush 8 50/60Hz Medium, Hi-Inrush /60Hz Long, Hi-Inrush 5 8 D, Short,Hi-Inrush 5 8 D,Medium, Hi-Inrush 56 D, Long, Hi-Inrush Actuator ode: A: Handle tie pin spacer(s) and retainers provided unassembled with multi-pole units. B: Handle location as viewed from front of breaker: pole - left pole pole - center pole pole - two handles at center poles 5 pole - three handles at center poles 6 pole - four handles at center poles S: Handle moves to mid-position only upon electrical trip of the breaker. Available with circuit codes B,, D, E, F, G, H and K. T: Handle moves to mid-position and alarm switch activates only upon electrical trip of the breaker. Available with circuit codes B &. Standard multipole units have all poles identical except when specifying auxilary switch and/or mixed poles. pole max w/vde. 5th pole available as Series Trip w/voltage oil only. Switch Only circuits, rated up to 50 amps and 6 poles, and only available with VDE ertification when tied to a protected pole (ircuit ode B,, D or H.), For.0 to 0 amps, select urrent ode 60. For 5-50 amps, select urrent ode 650. ircuit odes D,E,F,G,H & K available with Terminal odes,, & 5 only. ircuit odes D, F, H & K available up to 50 amps maximum urrent Rating. 5 onsult factory for available Dual oil options, as special catalog number is required. Dual oil Voltage oils with Shunt Trip onstruction trip instantaneously on line voltage. Dual oil Voltage oils require 0VA minimum power to trip instantaneously and are rated for intermittent duty only. 6 Auxiliary Switch available with Series Trip and Switch Only circuits. On multi-pole breakers, one aux. switch is supplied, mounted in the extreme right pole. 7 Voltage coils not rated for continuous duty. Available only with delay codes 0 and 0. 8 Available with ircuit odes B & D only, and up to 50 amps maximum. 9 urrent rating odes 660 through 80 are available with ircuit odes A & B only. urrent Ratings are available up to four poles maximum. Ratings 7-00 are available up to two poles maximum. 0 Terminal ode available to 60 amps maximum. Terminal odes,,5 and available to 50 amps maximum. Terminal odes,6 & 9 available to 00 amps maximum. Terminal ode 7 available to 5 amps maximum. Terminal ode A available to 00 amps maximum. 5 Terminal odes 7,8,9 & are not VDE approved. 6 No marking available. onsult factory. VDE Approval requires dual (I-O, ON-) or I-O markings on all handles. 7 Single pole only. 8 VDE/TUV: 0 amps max.; UL/SA: 50 amps max.; Available in - poles only and limited to A Delays. General Purpose amps not rated for full load amps or to be used in applications with a motor. 8 TERMINAL 5 0 Stud 0-, threaded.65 long Screw 8- w/saddle & washer clamps Stud /-0, threaded.65 long Stud M5 x 0.8, threaded 6mm long 5 Screw M5 x 0.8 w/saddle & washer clamp 6 Stud M6 threaded, 7mm long Double Quick onnect 8 / lip Terminal 9 7/6 lip Terminal A Plug-In Stud 5/6 lip Terminal 9 ATUATOR OLOR & LEGEND 6 Actuator olor I-O ON- Dual Legend olor White A B Black Black D White Red F G White Green H J White Blue K L 5 White Yellow M N 6 Black Gray P Q 7 Black Orange R S 8 Black Black (short handle) 7 T U 9 White 0 MOUNTING/BARRIERS MOUNTING STYLE BARRIERS VOLTAGE Threaded Insert 6- x 0.95 inches no < 00 A 6- X 0.95 inches yes < X 0.95 inches yes 00 ISO M x 5mm no < 00 B ISO M x 5mm yes < 00 D 8 ISO M x 5mm yes 00 Front panel Snap-In,.00 [5.mm] wide bezel E 7 with Handleguard no < 00 AGENY APPROVAL UL Recognized & SAertified D VDE ertified, UL Recognized & SAertified H UL89 onstruction: VDE ertified, UL Recognized & SA ertified I UL Rec. STD 077, UL Rec. 500 (ignition protected), & SAertified 6

67 -Series Handle Parallel Pole UL89A Ordering Scheme Series A P 0 D 80 M Actuator Poles ircuit 5 Aux/Alarm Switch 6 Frequency & Delay 7 urrent Rating 8 Terminal 9 Actuator olor 0 Mounting Max. App. Rating T Agency Approval SERIES ATUATOR A Handle, one per pole S Mid-Trip Handle, one per pole T Mid-Trip Handle, one per pole & Alarm Switch POLES Two Three IRUIT P Series Trip (Parallel Pole) 5 AUXILIARY/ALARM SWITH 0 w/o Aux Switch S.P.D.T., 0.0 Q.. Term. S.P.D.T., 0.9 Solder Lug S.P.D.T., 0.0 Q.. Term. (Gold ontacts) 6 FREQUENY & DELAY D D Ultra Short D D Short 7 URRENT RATING (AMPERES) S.P.S.T., 0.09 Q.. Term. (Gold ontacts) 6 S.P.S.T., 0.9 Solder Lug 7 S.P.S.T., 0.0 Q.. Term.(Gold ontacts) 8 S.P.S.T., 0.87 Q.. Term. 9 S.P.D.T., 0.87 Q.. Term. D D6 D Medium D Long TERMINAL / - 0 Threaded Stud,.675 long 6 M6 Threaded Stud, 7 mm long A Plug-In Stud 9 ATUATOR OLOR LEGEND ON- Dual Legend olor White B Black Black D White Red G White Green J White Blue L 5 White Yellow N 6 Black Gray Q 7 Black Orange S 8 Black 0 MOUNTING MOUNTING STYLE Threaded Insert 6- x 0.95 inches ISO M x 5mm MAXIMUM APPLIATION RATING M 80 D AGENY APPROVAL T UL89A Listed Actuator ode: A: Handle tie pin spacer(s) and retainers provided unassembled with multi-pole units. S: Handle moves to mid-position only upon electrical trip of the breaker. T: Handle moves to mid-position and alarm switch activates only upon electrical trip of the breaker. Terminal ode: & 6: Supplied with bus bars connecting the Line and Load Terminals. A: Line and Load Terminals must be connected to a copper bus bar having a minimum cross section of square inches. Above 00 amps, poles are required. 65

68 -Series Handle UL89 Ordering Scheme Series A B 0 50 K Actuator Poles ircuit 5 Aux/Alarm Switch 6 Frequency & Delay 7 urrent Rating 8 Terminal 9 Actuator olor 0 Mounting/ Barriers Max. App. Rating G Agency Approval SERIES ATUATOR A Handle, one per pole B Handle, one per multipole unit S Mid-Trip Handle, one per pole T Mid-Trip Handle, one per pole & Alarm Switch POLES One Two Three IRUIT B Series Trip (urrent) 5 AUXILIARY/ALARM SWITH 0 w/o Aux Switch S.P.D.T., 0.0 Q.. Term. S.P.D.T., 0.9 Solder Lug S.P.D.T., 0.0 Q.. Term. (Gold ontacts) 5 S.P.S.T., 0.0 Q.. Term. (Gold ontacts) 6 S.P.S.T., 0.9 Solder Lug 7 S.P.S.T., 0.0 Q.. Term.(Gold ontacts) 8 S.P.S.T., 0.87 Q.. Term. 9 S.P.D.T., 0.87 Q.. Term. 7 URRENT RATING (AMPERES) FREQUENY & DELAY D Ultra Short D Short D Medium 6 D Long 50/60Hz Ultra Short 50/60Hz Short 50/60Hz Medium 6 50/60Hz Long 50/60Hz Short, Hi-Inrush 50/60Hz Medium, Hi-Inrush 6 50/60Hz Long, Hi-Inrush 5 D, Short,Hi-Inrush 5 D,Medium, Hi-Inrush 56 D, Long, Hi-Inrush 8 TERMINAL 6 7 Stud 0-, threaded.65 long 8 Screw 8- w/saddle & washer clamps 9 Stud /-0, threaded.65 long 8 Stud M5 x 0.8, threaded 6mm long 5 8 Screw M5 x 0.8 w/saddle & washer clamp 6 9 Stud M6 threaded, 7mm long 8 / lip Terminal 9 9 7/6 lip Terminal A 0 Push-In Stud 5/6 lip Terminal 9 ATUATOR OLOR & LEGEND Actuator olor ON- Dual Legend olor White B Black Black D White Red G White Green J White Blue L 5 White Yellow N 6 Black Gray Q 7 Black Orange S 8 Black Actuator ode: A: Handle tie pin spacer(s) and retainers provided unassembled with multi-pole units. B: Handle located, as viewed from front of breaker in left pole. pole maximum. S: Handle moves to mid-position only upon electrical trip of the breaker. T: Handle moves to mid-position and alarm switch activates only upon electrical trip of the breaker. Standard multipole units have all poles identical except when specifying auxiliary switch and/or mixed poles. & pole circuit breakers required for 0/0 VA (Maximum application rating code ) applications, have all poles identical except when specifying auxiliary / alarm switch which is normally supplied in extreme right pole per figure B. These units are available with one handle per pole only and terminal barrier is required. Third pole is for 0/0 VA applications requiring neutral disconnect. The rd pole has the same construction as poles &. On multi-pole breakers, one auxiliary. switch is supplied, mounted in the extreme right pole. VDE approval on auxiliary switch codes, & only. Auxiliary / Alarm Switch with Independent ircuit ie: separate from breaker circuit, only available with circuit breakers rated 50 amp maximum at 80 VD, 5 VD, and 0 VA. Auxiliary / Alarm Switch with Dependent ircuit ie: same as circuit breaker, is supplied from factory with common terminal of auxiliary / alarm switch connected to line terminal on 0/0 and 0 VA ratings. ircuit breakers rated 0 VA 50 amp maximum can be supplied with Auxiliary/Alarm switch common terminal connected to breaker line terminal. onsult factory for special catalog number. Available up to 50 amps maximum. 5 urrent ratings 7-00 with VDE approvals are available up to two poles maximum. 6 Terminal odes 8, 9 & are not VDE approved. 7 Terminal ode available to 60 amps maximum. 8 Terminal odes,, 5 & available to 50 amps maximum. 9 Terminal odes, 6 & 9 available to 00 amps maximum. 0 Terminal ode A available to 00 amps maximum. VDE and TUV approvals require Dual (I-O, ON-) markings on all handles. 0 MOUNTING/BARRIERS MOUNTING STYLE BARRIERS Threaded Insert 6- x 0.95 inches yes ISO M x 5mm yes MAXIMUM APPLIATION RATING A 65 D B 5 D 0/0 A D 0 A K 0 A M 80 D AGENY APPROVAL A w/o approvals F UL89 Listed, SAertified & VDE ertified G UL89 Listed & SA ertified J UL89 Listed, SAertified & TUV ertified 66

69 -Series Rocker UL Recognized Ordering Scheme Series B D Actuator Poles ircuit 5 Aux/Alarm Switch 6 Frequency & Delay 7 urrent Rating 8 Terminal 9 Actuator olor 0 Mounting/ Barriers Agency Approval SERIES ATUATOR Two olor Visi-Rocker Indicate ON, vertical legend D Indicate ON, horizontal legend E Indicate ON, no legend F Indicate, vertical legend G Indicate, horizontal legend H Indicate, no legend Push-To-Reset, Visi-Rocker N Indicate, vertical legend O Indicate, horizontal legend P Indicate, no legend VERTIAL STYLE HORIZONTAL STYLE INDIATE OLOR LOATION Single color J Vertical legend K Horizontal legend L No legend Push-To-Reset, Single color R Vertical legend U Horizontal legend V No legend ROKER STYLE DESRIPTIONS INDIATE "ON" INDIATE "" SINGLE OLOR ODE "" ODE "F", "N" ODE "J", "R" ODE "D" POLES One Two Three ODE "G", "O" ODE "K", "U" 7 URRENT RATING (AMPERES) OR VOLTAGE OIL (MINAL RATED VOLTAGE) 7 A06 6 D A D J A A D A8 8 D J8 8 A A8 8 D A65 65 D J A A D J06 6 A J8 8 A J65 K0 L0 65 A 0 A 0 A IRUIT A Switch Only (No oil) B Series Trip (urrent) Series Trip (Voltage) D Shunt Trip (urrent) Shunt Trip (Voltage) E 5 AUXILIARY/ALARM SWITH 6 0 w/o Aux Switch S.P.D.T., 0.0 Q.. Term. S.P.D.T., 0.9 Solder Lug S.P.D.T., 0.0 Q.. Term. (Gold ontacts) 6 FREQUENY & DELAY 0 D 50/60Hz, Switch Only 0 7 D Instantaneous D Ultra Short D Short D Medium 6 D Long /60Hz Instantaneous 50/60Hz Ultra Short 50/60Hz Short 50/60Hz Medium 6 50/60Hz Long 5 S.P.S.T., 0.09 Q.. Term. (Gold ontacts) 6 S.P.S.T., 0.9 Solder Lug 7 S.P.S.T., 0.0 Q.. Term.(Gold ontacts) 8 S.P.S.T., 0.87 Q.. Term. 9 S.P.D.T., 0.87 Q.. Term. 0 D, 50/60Hz Instantaneous D, 50/60Hz Ultra Short D, 50/60Hz Short D, 50/60Hz Medium 6 D, 50/60Hz Long 8 50/60Hz Short, Hi-Inrush 8 50/60Hz Medium, Hi-Inrush /60Hz Long, Hi-Inrush 5 8 D, Short,Hi-Inrush 5 8 D,Medium, Hi-Inrush 56 8 D, Long, Hi-Inrush Push-To-Reset actuators have portion of rocker shrouded. Multi-pole breakers have all poles identical except when specifying Aux. switch and/or mixed poles, and have one rocker per breaker. Rocker location as viewed from front panel: pole left pole; pole center pole. Switch Only circuits, rated up to 50 amps and poles, and only available with VDE ertification when tied to a protected pole (ircuit ode B,, D or H.), For.0 to 0 amps, select urrent ode 60. For 5-50 amps, select urrent ode 650. ircuit odes D,E,F,G,H & K available with Terminal odes,, & 5 only. ircuit odes D,F,H & K available up to 50 amps maximum urrent Rating. 5 onsult factory for available Dual oil options, as special catalog number is required. Dual oil Voltage oils with Shunt Trip onstruction trip instantaneously on line voltage. Dual oil Voltage oils require 0VA minimum power to trip instantaneously and are rated for intermittent duty only. 6 Auxiliary Switch available with Series Trip and Switch Only circuits. On multi-pole breakers, one aux. switch is supplied, mounted in the extreme right pole.auxilary switch codes, & are VDE approved. 7 Voltage coils not rated for continuous duty. Available only with delay codes 0 and 0. 8 Available with ircuit odes B & D only, and up to 50 amps maximum. 9 urrent rating odes 660 through 80 are available with ircuit odes A & B only. Ratings 7-00 are available up to two poles maximum. Ratings are available up to four poles maximum. 0 Terminal ode available to 60 amps maximum. Terminal odes,,5 & available to 50 amps maximum. Terminal odes,6 & 9 available to 00 amps maximum. Terminal ode 7 available to 5 amps maximum. Terminal ode A available to 00 amps maximum. 5 Terminal odes 7,8,9 & are not VDE approved. 6 olor shown is visi and legend with remainder of rocker black 7 Legend on Push-to-reset bezel/shroud is white when single color rocker is ordered. Dual = ON-/I-O legend with actuator codes - G, and J, K, N, O, R, & U. None = no legend with actuator codes H, L, P, V. Rockerguard available with actuator codes - L. Push-to-reset available witha ctuator codes N, O, P, R, U, V. 8 VDE approval requires Dual (I-O, ON-) or I-O markings on rocker. 9 VDE/TUV: 0 amps max.; UL/SA: 50 amps max.; Available in - poles only and limited to A Delays. General Purpose amps not rated for full load amps or to be used in applications with a motor. F G H,5 K,5 Relay Trip (urrent) Relay Trip (Voltage) Dual oil with Shunt Trip Voltage oil Dual oil with Relay Trip Voltage oil 8 TERMINAL 0 Stud 0-, threaded.65 long Screw 8- w/saddle & washer clamps Stud /-0, threaded.65 long Stud M5 x 0.8, threaded 6mm long 5 Screw M5 x 0.8 w/saddle & washer clamp 6 Stud M6 threaded, 7mm long Double Quick onnect 8 / lip Terminal 9 7/6 lip Terminal A Plug-In Stud 5/6 lip Terminal 6, 7, 8 9 ATUATOR OLOR & LEGEND Actuator or Visi-olor Marking: Marking olor: Single olor olor: I-O ON- Dual/None Rocker/Handle Visi-Rocker White A B Black White Black D White n/a Red F G White Red Green H J White Green Blue K L 5 White Blue Yellow M N 6 Black Yellow Gray P Q 7 Black Gray Orange R S 8 Black Orange 0 MOUNTING/BARRIERS STANDARD ROKER BEZEL BARRIERS VOLTAGE 6- x 0.95 inches no <00 6- x 0.95 inches yes < x 0.95 inches yes 00 ISO M x 5mm no <00 5 ISO M x 5mm yes < ISO M x 5mm yes 00 ROKERGUARD BEZEL A 6- x 0.95 inches no <00 6- x 0.95 inches yes <00 E 9 6- x 0.95 inches yes 00 G ISO M x 5mm no <00 J ISO M x 5mm yes <00 L 9 ISO M x 5mm yes 00 PUSH-TO-RESET BEZEL B 6- x 0.95 inches no <00 D 6- x 0.95 inches yes <00 F 9 6- x 0.95 inches yes 00 H ISO M x 5mm no <00 J ISO M x 5mm yes <00 M 9 ISO M x 5mm yes 00 AGENY APPROVAL UL Recognized & SAertified D VDE ertified, UL Recognized & SAertified H UL89 onstruction: VDE ertified, UL Recognized & SA ertified I UL Rec. STD 077, UL Rec. 500 (ignition protected), & SAertified 67

70 -Series Rocker UL Listed Ordering Scheme Series B 0 50 A K Actuator Poles ircuit 5 Aux/Alarm Switch 6 Frequency & Delay 7 urrent Rating 8 Terminal 9 Actuator olor 0 Mounting/ Barriers Max. App. Rating G Agency Approval SERIES ATUATOR Two olor Visi-Rocker Indicate ON, vertical legend D Indicate ON, horizontal legend F Indicate, vertical legend G Indicate, horizontal legend VERTIAL STYLE HORIZONTAL STYLE INDIATE OLOR LOATION Single color J Vertical legend K Horizontal legend ROKER STYLE DESRIPTIONS INDIATE "ON" INDIATE "" SINGLE OLOR ODE "" ODE "F" ODE "J" ODE "D" ODE "G" POLES One Two Three IRUIT B Series Trip (urrent) 5 AUXILIARY/ALARM SWITH 0 w/o Aux Switch S.P.D.T., 0.0 Q.. Term. S.P.D.T., 0.9 Solder Lug S.P.D.T., 0.0 Q.. Term. (Gold ontacts) 6 FREQUENY & DELAY D Ultra Short D Short D Medium 6 D Long 50/60Hz Ultra Short 50/60Hz Short 50/60Hz Medium ODE "K" 5 S.P.S.T., 0.09 Q.. Term. (Gold ontacts) 6 S.P.S.T., 0.9 Solder Lug 7 S.P.S.T., 0.0 Q.. Term.(Gold ontacts) 8 S.P.S.T., 0.87 Q.. Term. 9 S.P.D.T., 0.87 Q.. Term. 6 50/60Hz Long 50/60Hz Short, Hi-Inrush 50/60Hz Medium, Hi-Inrush 6 50/60Hz Long, Hi-Inrush 5 D, Short,Hi-Inrush 5 D,Medium, Hi-Inrush 56 D, Long, Hi-Inrush 7 URRENT RATING (AMPERES) TERMINAL 5 Stud 0-, threaded.65 long 6 Screw 8- w/saddle & washer clamps 7 Stud /-0, threaded.65 long 6 Stud M5 x 0.8, threaded 6mm long Screw M5 x 0.8 w/saddle & washer clamp 6 7 Stud M6 threaded, 7mm long 8 8 / lip Terminal 9 7,8 7/6 lip Terminal A 7,8 Push-In Stud 5/6 lip Terminal 9 ATUATOR OLOR & LEGEND Actuator or Visi-olor 9 Marking: Marking olor: Single olor olor: ON- Dual 0 Rocker/Handle Visi-Rocker White B Black White Black D White n/a Red G White Red Green J White Green Blue L 5 White Blue Yellow N 6 Black Yellow Gray Q 7 Black Gray Orange S 8 Black Orange 6,8 0 MOUNTING/BARRIERS STANDARD ROKER BEZEL BARRIERS Threaded Insert, per pole A 6- X 0.95 inches yes ISO M x 5mm yes ROKERGUARD BEZEL Threaded Insert, per pole B 6- x 0.95 inches yes D ISO M x 5mm (multi-pole units only) yes Multi-pole breakers have all breakers identical except when specifying Aux. switch and/or mixed poles, and have one rocker per breaker. On multi-pole breakers, one aux. switch is supplied, mounted in the extreme right pole. Available up to 50 amps maximum. urrent ratings 7-00 with VDE approvals are available up to two poles maximum. 5 Terminal ode available to 60 amps maximum. 6 Terminal odes,, 5 & available to 50 amps maximum. 7 Terminal odes, 6, 9 & A available to 00 amps maximum. 8 Terminal odes 8, 9 & are not VDE approved. 9 olor shown is visi and legend with remainder of rocker black 0 Dual = ON-/I-O legend on actuator. VDE and TUV approval requires Dual (I-O, ON-) markings on rocker. Rockerguard available with all actuator codes. MAXIMUM APPLIATION RATING A 65 D B 5 D 0/0 A D 0 A K 0 A M 80 D AGENY APPROVAL A without approvals F UL 89 Listed, SAertified, & VDE ertified G UL 89 Listed & SAertified J UL89 Listed, SAertified & TUV ertified 68

71 -Series Handle ircuit & Terminal Diagrams DESRIPTION ODE TERMINAL DIMENSIONAL DETAIL.65 [5.880] RATING (AMPS) IRUIT BREAKER MODE HANDLE POSITION VS. AUX/ALARM SWITH MODE STANDARD /B HANDLE POSITION AUX. SWITH MODE HANDLE POSITION MID TRIP /B STANDARD ALARM SWITH MODE REVERSE ALARM SWITH MODE #0- STUD [.90] O N O N N.60 [6.000] ON I ON I M5 STUD #/-0 STUD.5 [5.60].675 [7.5] ON ELETRIAL TRIP 0 0 O N N 0 90 N N N N.5 [5.970].669 [7.000].850 [7.9] TYP.8 [7.] TYP M6 STUD 6.6 [6.70] MID TRIP ON I.750 [69.85] #0- SREW O.90 [9.8] TYP M-5 SREW.50 DOUBLE Q ±.05 ±.8.50 [.80].00 [0.60].80 [0.80].50 [6.50] TYPIAL TERMINAL BARRIER STUD TERMINAL VERSION IS SUPPLIED WITH HEX NUTS AND FLAT WASHERS/TERMINAL. SREW TERMINAL VERSION IS SUPPLIED WITH #0- SREW, FLAT WASHER AND SADDLE LAMP/TERMINAL. THE SADDLE LAMP IS FOR DIRET WIRE ONNETION USE. DISARD SADDLE LAMP IF WIRE TERMINAL LUG IS USED.080 [78.].980 [.89] TYP.7 [.90].0 [8.0] /" LIP TERMINALS 8.8[7.].50 DIA [Ø6.5] OMPONENT DIA.0[0.8] ON I O.90 [9.8].900 [99.06].75[9.5].566[.8].850 [7.00] 7/6" LIP TERMINALS 9.7 DIA [Ø.0] OMPONENT DIA.6[6.6] SPEIAL TERMINAL BARRIER REQUIRED FOR U.L. 89 LISTED IRUIT BREAKERS WITH 0/0 VA RATINGS AUXILIARY / ALARM SWITH TERMINAL DETAIL. [7.9].05 DIA [Ø.9].0 [.80].070 DIA [Ø.80].90[.89].960[.8].87 [7.9].87 [.75].0 [.80].6 [.0] PUSH-IN STUD A Ø. [7.90] TAB (Q..).87 TAB (Q..).0 SOLDER TYPE.558[.7] ENTER OF PUSH-IN STUD ONTAT AREA PUSH-IN STUD MATING HOLE TE: TOLERANE ON STUD LENGTHS IS ±.0 [±.79] UNLESS OTHERWISE SPEIFIED All dimensions are in inches [millimeters]. Tolerance ±.00 [.5] unless otherwise specified. Available on Series Trip and Switch Only ircuits when called for on multi-pole units. Only one aux. switch is normally supplied, as viewed in mulit-pole identification scheme. Available only as special catalog number. 69

72 -Series Handle ircuit & Terminal Diagrams.850 [7.00] TYP. ANSI IRUIT SHEMATI SWITH ONLY ( OIL) IE IRUIT ODE AUX SWITH ODE IRUIT SHEMATI ANSI SERIES TRIP IE IRUIT ODE AUX SWITH ODE (NETZ) () (NETZ) MAIN TERM'S. (SEE TABLE-A) A O B O ±.0 ± [5.88] TYP..50 [57.5] TYP..675 [7.5] TYP SWITH ONLY ( OIL) WITH AUXILIARY SWITH (LAST) (NETZ) SERIES TRIP WITH AUXILIARY / ALARM SWITH STD. AUX. SWITH I > (LAST) (NETZ) () STD. AUX. SWITH.65[.] TYP. N.970[.6] AUX SWITH TERM. ( PLS.) N N (LAST) SHUNT TRIP (NETZ) () A ALARM SWITH N I > DUAL OIL; SERIES TRIP URRENT OIL, SHUNT TRIP VOLTAGE OIL (NETZ) N ALARM SWITH (LAST) B SHUNT SHUNT (NEBENSHLUSS) D E 0 H 0 I > VOLTAGE OIL I > U > ±.0 ± [5.88] TYP ±.0 ±.79.8 [0.6] TYP.66 [6.].66 [6.] TYP. RELAY RELAY RELAY TRIP (LAST) RELAY (RELAIS) I > RELAY (RELAIS) (NETZ) (LAST) () F G 0 VOLTAGE OIL (LAST) DUAL OIL; SERIES TRIP URRENT OIL, RELAY TRIP VOLTAGE OIL (NETZ) I > VOLTAGE OIL VOLTAGE OIL U > VOLTAGE (LAST) OIL K 0 #6- [M] MOUNTING INSERTS #0- & M5 THD STUDS #0- THD SREW #/-0 & M6 THD STUDS TABLE A TIGHTENING TORQUE SPEIFIATIONS THREAD SIZE TORQUE 7-9 IN-LBS [ NM] 5-0 IN-LBS [.7-. NM] 5-0 IN-LBS [.7-. NM] 0-5 IN-LBS [.-.0 NM] All dimensions are in inches [millimeters]. Tolerance ±.05 [.8] unless otherwise specified. Schematic shown represents current trip circuits. 70

73 -Series Handle Form & Fit Drawings # 6- [M] THREADED x.95 [.95] DEEP ( PL'S.) / POLE TYPIAL-OPTIONAL "ON-OF, I-O" LEGEND ON I.5 [8.58].06 [0.] ±.060 ±.5.75 [6.87] TYP.850 [7.00] TYP TYPIAL TERMINAL BARRIER -POLE (A) O.8 [6.5].06 [5.7] [6.50] TYP. ±.00 ±.5.90 [9.8] TYP. O.755 [9.8] MAX..50 [.7].50 [.8] TYP. ±.00 ±.5.8 [7.] TYP MULTI-POLE UNITS ARE ASSEMBLED AT FATORY WITH OMMON HANDLE TIE..5 [.] (SHORT HANDLE) #0- THREADED STUD TERMINALS IN SERIES TRIP IRUIT ONFIGURATION SHOWN. FOR OTHER ONFIGURATIONS, SEE IRUIT AND TERMINAL DIAGRAMS.00 [77.] -POLE (A) -POLE (B).80 [57.9].50 [8.6].760 [9.0].56 DIA. [Ø.96] PL'S. TYP. PER POLE.55 [8.8] MAX..750 [9.05].55 [8.8] MAX..06 [5.7].8 [6.78] -POLE (A) -POLE (B). [0.97] A B B A B A.750 [9.05] TYP..65 [57.5] MAX..750 [9.05].65 [57.5] MAX. A PANEL UTOUT DETAIL TOLERANES ±.005 [.] -POLE (A) -POLE (B).750 [9.05] TYP..05 [76.58] MAX..05 [76.58] MAX. ±.00 [.0].550 [6.77] ±.05 [.8].687 [7.5] ±.05 [.8].995 [5.7] ±.005 [.].760 [9.0] ±.00 [.50].65 [5.87] ±.05 [.8].96 [7.99] SNAP-IN ±.00 [.50].90 [9.7] ±.05 [.8].560 [9.6] ±.05 [.8].88 [80.97] O ±.007 [.77].98 [7.6] /-0 STUDS.850 [6.99] TYP PANEL UT-OUT PANEL THIKNESS 0.0 TO 0.0 INHES [.0] TO [.5] INHES All dimensions are in inches [millimeters]. Tolerance ±.00 [.5] unless otherwise specified. 7

74 -Series HandleGuard Form & Fit Drawings.55 [9.].6 [.07].50 [6.0] TYP.895 [8.] TYP ON I -POLE (A).560 [65.0] TYP 0.06 [5.7] TYP.8 [6.5] TYP [9.8] TYP.500 [6.50] TYP O.750 [9.05] MAX #6- THREAD X.95 [.95] DEEP ( PLS) / POLE.05 [.67].50 [.7].70 [8.80].8 [7.] TYP TYP-OPTIONAL "ON-0FF", I-O LEGEND.56 DIA [.96] PLS PER POLE TYP.760 [9.0] PER POLE TYP.50 [8.6] -POLE (A) 0 0 -POLE (B) 0.06 [5.7].8 [6.78].750 [9.05] MAX.55 [8.8] MAX.55 [8.8] MAX. [0.97] A,B,B B PANEL UTOUT DETAIL -POLE (B) [.7] ENTER OF PUSH-IN STUD ONTAT AREA.960 [.8] Ø. [7.90].65 [57.5] MAX.750 [9.05] MAX PUSH-IN STUD PUSH-IN STUD MATING HOLE.675[7.50].65 [5.88] -POLE (B) 0 0.5[5.970].65[.9] #/-0 STUD #0- STUD TERMINAL DETAILS.05 [76.58] MAX.750 [9.05] MAX All dimensions are in inches [millimeters]. Tolerance ±.00 [.5] unless otherwise specified. Available as special catalog number only. 7

75 O O O arling -Series Parallel Pole Form & Fit Drawings PARALLEL POLE (A-P) #6- [M] THREADED x.95 [.95] DEEP ( PL'S.) / POLE TYPIAL-OPTIONAL "ON-OF, I-O" LEGEND ON I.5 [8.58].06 [0.] ±.060 ±.5.75 [6.87] TYP.850 [7.00] TYP.75 [.6] O O.8 [6.5].06 [5.7] 60 0 ±.00 ±.5.90 [9.8] TYP.500 [6.50] TYP.65 [5.66].565 [65.0] O.55 [8.8] MAX..750 [9.05].50 [.7].50 [.8] TYP ±.00 ±.5.8 [7.] TYP # /-0 THREADED STUD SHOWN PARALLEL POLE (A-P) TYPIAL-OPTIONAL "ON-OF, I-O" LEGEND IRUIT BREAKER PROFILE ±.060 ±.5.88 [7.00] TYP ANSI IRUIT SHEMATI SERIES TRIP IE (NETZ) IRUIT ODE AUX SWITH ODE P 0 I > (LAST).00 [0.6] PUSH-IN STUD SERIES TRIP WITH AUXILIARY SWITH.65 [57.5] MAX..750 [9.05] (NETZ) P N I > N.5 [5.7] (LAST) TERMINAL DETAILS PANEL UTOUT DETAIL TOLERANES ±.005 [.].960 [.8].558 [.7] ENTER OF PUSH-IN STUD ONTAT AREA.675[7.50].80 [57.9] (A-P).50 [9.0] (A-P) PUSH-IN STUD (SEE TE ).58 [.0].6 [9.].06 [5.7].8 [6.78] PUSH-IN STUD MATING HOLE Ø. [7.90] #/-0 STUD. [0.97].56 DIA [Ø.96] PL'S. TYP. PER POLE All dimensions are in inches [millimeters]. Tolerance ±.00 [.5] unless otherwise specified. Line and Load terminals must be paralleled with copper bus with a minimum cross section of.078 square inches [50. sq. mm.]. 7

76 -Series Rocker ircuit & Terminal Diagrams IRUIT BREAKER PROFILE.60 [5.86] TYP IRUIT SHEMATI ANSI IE SWITH ONLY ( OIL) (NETZ) IRUIT ODE AUX SWITH ODE ANSI IRUIT SHEMATI IE SWITH TRIP (NETZ) () IRUIT ODE AUX SWITH ODE SERIES TRIP ( TERM'S.) MAIN TERM'S. (SEE TABLE-A) A 0 B 0 I > ±.0 [±.79].65 [5.88] TYP.675[7.5] TYP SWITH ONLY ( OIL) WITH AUXILIARY SWITH (LAST) (LAST) SERIES TRIP WITH AUXILIARY SWITH.970 [.6] (NETZ) (NETZ) () SERIES TRIP W/AUX. SWITH (5 TERM'S.) N.65 [.] AUX. SWITH TERM'S.( PLS.) N N (LAST) A N I > (LAST) N B SHUNT TRIP (NETZ) () DUAL OIL; SERIES TRIP URRENT OIL, SHUNT TRIP VOLTAGE OIL (NETZ) SHUNT TRIP ( TERM'S.) SHUNT (NEBENSHLUSS) DE 0 H 0 SHUNT I > (LAST) VOLTAGE OIL I > (LAST) U > VOLTAGE OIL SHUNT TRIP ( TERM'S.) ±.0 [±.79].65 [5.88] TYP ±.0 [±.79].8 [0.6] TYP.66 [6.].66 [6.] TYP RELAY RELAY RELAY TRIP RELAY () (RELAIS) (NETZ) FG 0 VOLTAGE OIL I > RELAY (RELAIS) (LAST) DUAL OIL; SERIES TRIP URRENT OIL, RELAY TRIP VOLTAGE OIL (NETZ) I > (LAST) VOLTAGE OIL U > VOLTAGE OIL K 0 TABLE A TIGHTENING TORQUE SPEIFIATIONS THREAD SIZE TORQUE #6- [M] MOUNTING INSERTS 7-9 IN-LBS [0.8-.0] NM #0- & M5 THD STUDS #0- & M5 THD SREW #/-0 & M6 THD STUDS 5-0 IN-LBS [.7-.] NM 5-0 IN-LBS [.7-.] NM 0-5 IN-LBS [.-.0] NM All dimensions are in inches [millimeters]. Tolerance ±.05 [.8] unless otherwise specified. 7

77 -Series Rocker ircuit & Terminal Diagrams TERMINAL DESRIPTION ODE DIMENSIONAL DETAIL.65 [5.880] 5 RATING (AMPS) #0- STUD.65 [.90].60 [6.000].60 [80.6] TYP.8 [7.] TYP M5 STUD.5 [5.60].675 [7.5].90 [9.8] TYP.750 [69.85] TYP #/-0 STUD.5 [5.970].669 [7.000].850 [7.00] TYPIAL TERMINAL BARRIER M6 STUD 6.6 [6.70] STUD TERMINAL VERSION IS SUPPLIED WITH HEX NUTS AND FLAT WASHERS / TERMINAL. SREW TERMINAL VERSION IS SUPPLIED WITH #0- SREW, FLAT WASHER AND SADDLE LAMP / TERMINAL. THE SADDLE LAMP IS FOR DIRET WIRE ONNETION USE. DISARD SADDLE LAMP IF WIRE TERMINAL LUG IS USED #0- SREW M-5 SREW.50 DOUBLE Q.. ±.05 ± [.80].00 [0.60].80 [0.80] 7.50 [6.50].7 [.90].0 [8.0] AUXILIARY / ALARM SWITH TERMINAL DETAIL.070 DIA [Ø.80]. [7.9].05 DIA [Ø.9].0 [.80].87 [7.9].87 [.75].0 [.80].6 [.0] TAB (Q..).87 TAB (Q..).0 SOLDER TYPE /" LIP TERMINALS 8.8[7.].50 DIA [Ø6.5] OMPONENT DIA.0[0.8] TES:. ALL DIMENSIONS ARE IN INHES [mm]. TOLERANE ±.00 [.5] UNLESS OTHERWISE SPEIFIED.. AVAILABLE ON SERIES TRIP AND SWITH ONLY IRUITS WHEN ALLED FOR ON MULTI-POLE UNITS, ONLY ONE AUX. SWITH IS RMALLY SUPPLIED, AS VIEWED IN MULTI-POLE IDENTIFIATION SHEME..75[9.5].566[.8] TABLE A TIGHTENING TORQUE SPEIFIATIONS THREAD SIZE TORQUE 7/6" LIP TERMINALS 9.7 DIA [Ø.0] OMPONENT DIA.6[6.6] #6- [M] MOUNTING INSERTS #0- & M5 THD STUDS #0- & M5 THD SREW 7-9 IN-LBS 5-0 IN-LBS 5-0 IN-LBS.90[.89].960[.8] #/-0 & M6 THD STUDS 0-5 IN-LBS PUSH-IN STUD A Ø. [7.90].558[.7] ENTER OF PUSH-IN STUD ONTAT AREA PUSH-IN STUD MATING HOLE TE: TOLERANE ON STUD LENGTHS IS ±.0 [±.79] UNLESS OTHERWISE SPEIFIED All dimensions are in inches [millimeters]. Tolerance ±.00 [.5] unless otherwise specified. 75

78 -Series Rocker Form & Fit Drawings INDIATE "ON" INDIATE "" & SINGLE OLOR (INDIATE "" SHOWN).0 [0.670].0 [.08].5 [8.58] SREW TYPE TERMINALS IN SERIES TRIP IRUIT ONFIGURATION SHOWN. FOR OTHER ONFIGURATIONS SEE IRUIT AND TERM. DIAGRAMS.60 [5.860].850 [7.000].0 [7.870] OPTIONAL "ROKER GUARD" SHOWN IN PHANTOM ON.5 [.6] ON.500 [6.5].08 [5.8].5 [6.850] SREW TYPE.755 [9.80] MAX. BREAKER WIDTH.5 [8.580] L OF ROKER, & PANEL UT-OUT. F OPTIONAL "PUSH-TO RESET" ATUATOR ON.660 [.60]. [0.970] ON.5 [.60] ON.6 [5.80].75 [8.90] MAX. ROKER ADAPTER BRAKET WIDTH.5 [.60].90 [9.8].500 [6.50].055 x.05 SLOTTED HOLE (ROKER ATUATION).65 [.80] F ROKER SHROUDED ON "" POSITION SIDE, SHOWN IN DASHED S..660 [.6].06 [5.70] TYP. ON OPTIONAL "ROKER GUARD" SHOWN IN DASHED S ON.750 [9.05] TYP..55 [8.80] MAX. PANEL UT-OUT DETAIL [9.050] F ±.005 ±..60 [.000].660 [.6] ON ON.65 [57.50] MAX. P() P() P() (SEE TE-).00 [5.080].56 DIA [Ø.960] () HOLES P() P() P() (SEE TE-) Dimensions apply to all variations shown. Notice that circuit breaker line and load terminal orientation on indicate is opposite of indicate ON. For pole orientation with horizontal legend, rotate front view clockwise 90. All dimensions are in inches [millimeters]. Tolerance ±.05 [.8] unless otherwise specified. 76

79 D-Series General Specifications Designed for snap-on-back panel rail mounting on either a 5mm x 7.5mm, or a 5mm x 5mm Symmetrical Din Rail, allowing rapid and simple mounting and removal of the breaker. It features recessed, wire-ready, touch-proof, shock-resistant terminals, suitable for automatic screwdriver assembly, as well as "Dead Front" construction characteristics. Available with a Visi-Rocker two-color actuator, which can be specified to indicate either the ON or the TRIPPED/ mode, or solid color rocker or handle type actuators. All actuator types fit in the same industry standard panel cutouts amps, up to 80 VA or 65 VD, - poles (Handle), - poles (Rocker), with a choice of time delays. Agency ertifications UL Recognized UL Standard 077 omponent Recognition Program as Protectors, Supplementary (Guide QVNU, File E75596) SA ertified omponent Supplementary Protector under lass 5 0, FIle SA Standard. No. 5 UL Standard 508 Switches, Industrial ontrol (Guide NRNT, File E868) VDE ertified EN609, VDE 06 under File No. 057 Electrical Table A: Lists UL Recognized and SA and VDE ertified configurations and performance capabilities as a omponent Supplementary Protector. D-SERIES TABLE A: OMPONENT SUPPLEMENTARY PROTETOR VOLTAGE URRENT INTERRUPTING APAITY (AMPS) RATING UL / SA VDE IRUIT MAX FULL WITH WITHOUT (Inc) WITH (Icn) WITHOUT ONFIGURATION RATING FREQUENY PHASE AMPS BAKUP FUSE BAKUP FUSE BAKUP FUSE BAKUP FUSE 65 D /50 50/60 and SERIES 50 50/60 and / Y 50/60 and D /60 and SWITH ONLY 77 50/ Y 50/ Y 50/ Notes for Table A: D and Ø 77 Volt ratings are or poles breaking. Ø Ratings are poles breaking. Requires branch circuit backup with a UL LISTED Type K5 or RK5 fuse rated 5A minimum and no more than times full load amps not to exceed 50A for 50 Volt rating and 5A for 77 and 80 Volt ratings. UL Recognition and SA ertification at 80 Volts refers to and pole versions, used only in a Ø wye connected circuit or pole versions connected with poles breaking Ø and backed up with series fusing per note. 77

80 D-Series General Specifications Electrical Mechanical Maximum Voltage A, 80 wye/77 VA (See Table A), 50/60 Hz, 65VD Standard current coils 0.00, 0.50, 0.500, 0.750,.00,.50, 5.00, 7.50, 0.0, 5.0, 0.0, 5.0, 0.0, 5.0, 0.0 & Other ratings available - consult factory. Standard Voltage oils D - 6V, V; A - 0V, other ratings available, see ordering scheme. Insulation Resistance Minimum of 00 Megohms at 500 VD. Dielectric Strength UL, SA: 960 V 50/60 Hz for one minute between all electrically isolated terminals. D-Series circuit breakers comply with the 8mm spacing and 750V 50/60 Hz dielectric requirements from hazardous voltage to operator accessible surfaces and between adjacent poles per Publications EN and VDE Resistance, Impedance Values from Line to Load Terminal - based on Series Trip ircuit Breaker RESISTANE, IMPEDANE VALUES from Line to Load Terminals (Values Based on Series Trip ircuit Breaker) 000 O H M S Pulse Tolerance urves Multiple of Rated urrent 5x x I r 0 00 AMPERE RATING 60 Hz / ycle Inrush Pulse Tolerance Time Delay urves, & 6 (50 Amps Max.) Time Delay urves,, 6 (70 Amps Max.) t 6.67 Time in Milliseconds Multiple of Rated urrent x 0x I r URRENT TOLERANE (AMPS) (%) ± 5% ± 5% ± 5% 50 Hz / ycle Inrush Pulse Tolerance Time Delay urves, & 6 (50 Amps Max.) Time Delay urves,, 6 (70 Amps Max) 0.0 Time in Milliseconds t Endurance Trip Free Trip Indication Physical 0,000 ON- 6 per minute; with rated urrent and Voltage. All D-Series ircuit Breakers will trip on overload, even when actuator is forcibly held in the ON position. The operating actuator moves positively to the position when an overload causes the breaker to trip. Number of Poles Rocker Type: -; Handle Type: - Internal ircuit onfig. Switch Only and Series Trip with current or voltage trip coils. Weigh Approximately 8 grams/pole (Approximately.57 ounces/pole) Standard olors Housing - Black; Actuator - See Ordering Scheme. Mounting Mounts on a standard 5mm Symmetrical DIN Rail (5 x 7.5 or 5 x 5mm per DIN EN500). Environmental Designed and tested in accordance with requirements of specification MIL-PRF-5569 & MIL-STD-0 as follows: Shock Withstands 00 Gs, 6ms, sawtooth while carrying rated current per Method, Test ondition "I". Instantaneous and ultra-short curves 90% of rated current. Vibration Withstands 0.060" excursion from 0-55 Hz, and 0 Gs Hz, at rated current per Method 0, Test ondition A. Instantaneous and ultra-short curves tested at 90% of rated current. Moisture Resistance Method 06D, i.e., ten -hour + 5 to +65, 80-98% RH. Salt Spray Method 0, ondition A (90-95% 5% Nal Solution, 96 hrs). Thermal Shock Method 07D, ondition A (Five -55 to +5 to +85 to +5 ). Operating Temperature -0 to

81 D Series D-Series Handle & Rocker Ordering Scheme A B Actuator Poles ircuit 5 Frequency & Delay 6 urrent Rating 7 Terminal 8 Actuator olor 9 Mounting/ Voltage 0 Agency Approval SERIES D ATUATOR Handle A Handle, one per pole B Handle, one per multipole unit Visi-Rocker Indicate ON, vertical legend D Indicate ON, horizontal legend E Indicate ON, no legend (VDE approval not available with no legend) F Indicate, vertical legend G Indicate, horizontal legend H Indicate, no legend (VDE approval not available with no legend) Single olor Rocker J Vertical legend K Horizontal legend L No legend (VDE approval not available with no legend) VERTIAL STYLE HORIZONTAL STYLE INDIATE OLOR LOATION POLES One Two Three Four IRUIT A0 Switch Only (No oil) B0 Series Trip (urrent) 0 Series Trip (Voltage) 5 FREQUENY & DELAY 0 D 50/60Hz, Switch Only 0 5 D Instantaneous D Ultra Short D Short D Medium 6 D Long /60Hz Instantaneous 50/60Hz Ultra Short 50/60Hz Short 50/60Hz Medium ROKER STYLE DESRIPTIONS INDIATE "ON" INDIATE "" SINGLE OLOR ODE "" ODE "F", "N" ODE "J", "R" ODE "D" FIG B ODE "G", "O" ODE "K", "U" 6 50/60Hz Long D, 50/60Hz Short D, 50/60Hz Medium 6 D, 50/60Hz Long 6 50/60Hz Short, Hi-Inrush 6 50/60Hz Medium, Hi-Inrush /60Hz Long, Hi-Inrush 5 7 D, Short,Hi-Inrush 5 7 D,Medium, Hi-Inrush 56 7 D, Long, Hi-Inrush 6 URRENT RATING (AMPERES) OR VOLTAGE OIL (VOLTS, MIN. TRIP RATING) 5 A06 6 D, 5 D A8 8 D, 0 D A D, 0 D A65 65 D, 55 D A8 8 D, 5 D J06 6 A, 5 A A D, 0 D J A, 0 A A D, 5 D J8 8 A, 5 A 7 TERMINAL #0 Screw & Pressure Plate for Direct Wire onnection #0 Screw without Pressure Plate J A, 0 A J8 8 A, 0 A K0 0 A, 65 A L0 0 A, 0 A 8 ATUATOR OLOR & LEGEND Actuator or Visi-olor Marking: Marking olor: Single olor Visi-Rocker olor: I-O ON- Dual Rocker/Handle (Actuator Black) 8 White A B Black White Black D White n/a Red F G White Red Green H J White Green Blue K L 5 White Blue Yellow M N 6 Black Yellow Gray P Q 7 Black Gray Orange R S 8 Black Orange 9 MOUNTING/VOLTAGE MOUNTING STYLE VOLTAGE Threaded Insert 6- x 0.95 inches < X 0.95 inches 00 ISO M x 5mm < 00 D 9 ISO M x 5mm 00 0 AGENY APPROVAL UL Recognized & SAertified D VDE ertified, UL Recognized & SAertified Handle breakers available up to four poles. Rocker breakers available up to three poles. Actuator ode: A: Multi-pole units factory assembled with common handle tie. B: Handle location as viewed from front of breaker: pole - left pole pole - center pole pole - two handles at center poles Multipole rocker breakers have one rocker per breaker, as viewed from the front of the panel. Two pole - left pole. Three pole - center pole 0A, select urrent Rating code A, select urrent Rating code Voltage coil only available with delay codes 0 & 0. 6 Available to 50A max with circuit code BO only. 7 Available to 50A (UL/SA), 0A (VDE) with circuit code BO only. 8 olor shown is visi and legend with remainder of rocker black. 9 00V: Three pole breaker Ø or pole breaker Ø, UL/SA limited to 0 FLA max. 0 VDE Approval requires Dual (I-O, ON-) or I-O markings 79

82 D-Series ircuit & Terminal Diagrams HANDLE ATUATOR ROKER ATUATOR INDIATE "ON" SERIES TRIP ( TERM'S.) SWITH ONLY ( TERM'S.) MULTI-POLE IDENTIFIATION SHEME P0LE P0LE P0LE ROKER ATUATOR INDIATE "" & SINGLE OLOR SERIES TRIP ( TERM'S.) SWITH ONLY ( TERM'S.) MULTI-POLE IDENTIFIATION SHEME P0LE P0LE P0LE (HANDLE ATUATOR SHOWN).6 [8.79] TYP.65 [5.99] TYP ON I TABLE A TIGHTENING TORQUE SPEIFIATIONS.90 [7.7] TYP I.6 [9.75] TYP THREAD SIZE #6- [M] HARDWARE #0- THD TERMINAL SREW TORQUE 7-9 IN-LBS [ NM] 5-0 IN-LBS [.7-. NM].0 [.9] TYP TERMINALS ARE SUPPLIED WITH #0- SREW AND PRESSURE PLATE PER TERMINAL" All dimensions are in inches [millimeters]. Tolerance ±.05 [.8] unless otherwise specified. 80

83 D-Series Rocker Form & Fit Drawings # 0- x.75 LONG SREW ( REQ'D.) / POLE INDIATE "ON" INDIATE "" & SINGLE OLOR (INDIATE "" SHOWN).6 [8.79] # 6- [M] THREAD x.95 [.95] DEEP ( PL'S.) / POLE.65 [5.99] TYP.775 [9.68].06 [5.7] TYP.96 [.].99 [9.00].68 [.69] -POLE (D).90 [7.7] TYP -POLE (DF).8 [6.5] TYP.755 [9.8] MAX..0 [0.9] TYP.590 [.98].6 [9.75] TYP.0 [5.8].68 [.69] REF.705 [7.90].0 [.9] -POLE (D) -POLE (DF).750 [9.05].55 [8.8] MAX. -POLE (D) -POLE (DF).750 [9.05] TYP STANDARD 5mm SYMMETRIAL DIN RAIL (5 x 7.5 OR 5 x 5mm PER DIN EN500) P() P() P() (SEE TE ).65 [57.5] MAX P() P() P() (SEE TE ) SREW DRIVER ASSEMBLY REMOVAL All dimensions are in inches [millimeters]. Tolerance ±.05 [.8] unless otherwise specified. Dimensions apply to all variations shown. Notice that circuit breaker line and load terminal orientation on indicate is opposite of indicate ON. For pole orientation with horizontal legend, rotate front view clockwise 90. 8

84 D-Series Handle Form & Fit Drawings.6 [8.79] # 0- x.75 LONG SREW ( REQ'D) / POLE # 6- [M] THREAD x.95 [.95] DEEP ( PL'S.) / POLE ON I.68 [.69].96 [.].99 [9.00].65 [5.99] TYP.705 [7.9].0 [5.8].775 [9.68] -POLE (DA).755 [9.8] MAX..8 [6.5] TYP.06 [5.7] TYP TYPIAL-OPTIONAL "ON-, I-O" LEGEND.90 [7.7] TYP 60 O 0.50 [.8] TYP.50 [.7].6 [9.75] TYP MULTI-POLE UNITS ARE ASSEMBLED AT FATORY WITH OMMON HANDLE TIE.0 [.9] TYP -POLE (DA) -POLE (DB).750 [9.05].55 [8.8].55 [8.8].00 [77.].56 DIA [Ø.96] PL'S TYP PER POLE.80 [57.9].50 [8.6] -POLE (DA) -POLE (DB).760 [9.0] TYP. PER POLE.8 [6.78].06 [5.7].65 [57.5] MAX..750 [9.05] MAX..65 [57.5] MAX.. [0.97] DA DB DB DA DB.750 [9.05] TYP DA DA -POLE (DA) -POLE (DB) PANEL UTOUT DETAIL TOLERANES ±.005 [.].05 [76.58] MAX..750 [9.05].05 [76.58] TYP. MAX. STANDARD 5mm SYMMETRIAL DIN RAIL (5 x 7.5 OR 5 x 5mm PER DIN EN500). SREW DRIVER ASSEMBLY REMOVAL All dimensions are in inches [millimeters]. Tolerance ±.00 [.5] unless otherwise specified. 8

85 E-Series General Specifications Ideally suited for higher amperage applications. Available with front and back mounting, screw terminals, stud terminals and heavy duty box wire connectors for solid wire or a pressure plate connector for stranded wire. Power selector device available, consult factory. The E-Series is UL Listed and SA ertified for Branch ircuit protection which does not require a fuse backup. It is also UL Recognized and SA ertified as a Supplementary Protector and as a Manual Motor ontroller. -6 poles, amps, up to 600 VA or 5 VD, with choice of time delays and actuator colors. Agency ertifications UL Recognized UL Standard 077 UL Standard 508 UL Standard 500 UL Listed UL Standard 89 omponent Recognition Program as Protectors, Supplementary (Guide QVNU, File E75596) omponent Recognition Program as Manual Motor ontrols (Guide NLRV, File E567) Protectors, Supplementary for Marine Electrical & Fuel Systems (Guide PEQZ, File E75596) Ignition Protection ircuit Breakers, Molded ase, (Guide DIVQ, File E9899) SA ertified VDE ertified omponent Supplementary Protector (lass 5 0, FIle ) SA Standard. No. 5 ircuit Breaker Molded ase (lass 0, File 0990), SA Standard. No M EN609, VDE 06 under File No. 057 Electrical Table A: Lists UL Listed (89) & SA ertified (. No. 5) configurations & performance capabilities as a Molded ase ircuit Breaker. E-SERIES TABLE A: UL89 LISTED BRANH IRUIT PROTETOR URRENT VOLTAGE RATING INTERRUPTING IRUIT MAX FULL APAITY ONFIGURATION RATING FREQUENY PHASE AMPS (AMPS) 65 D ,000 SERIES 5 D /0 50/ /60 &

86 E-Series General Specifications Electrical Table B: Lists UL Recognized & SA ertified configurations & performance capabilities as a omponent Supplementary E-SERIES TABLE B: OMPONENT SUPPLEMENTARY PROTETOR VOLTAGE URRENT RATING INTERRUPTING APAITY (AMPS) UL / SA IRUIT MAX FULL WITH WITHOUT ONFIGURATION RATING FREQUENY PHASE AMPS BAKUP FUSE BAKUP FUSE ONSTRUTION TES 5 D D SERIES 0/0 50/ & 0 50/60 & , SHUNT 77 50/ , /60 & , Poles Breaking Ø; - Poles /60 & , Breaking Ø 5 D D SWITH ONLY 0 50/60 & Notes for Table B: 77 50/ Requires branch circuit backup with a UL LISTED Type K5 or RK5 fuse rated 5A minimum 80 50/60 & and no more than times full load amp rating and not to exceed 5 amps /60 & Table : Lists UL Recognized, SA and VDE ertified configurations and performance capabilities as a omponent Supplementary Protector. E-SERIES TABLE : OMPONENT SUPPLEMENTARY PROTETOR VOLTAGE URRENT INTERRUPTING APAITY (AMPS) RATING UL / SA VDE IRUIT MAX FULL WITH WITHOUT (Icn) WITHOUT ONFIGURATION RATING FREQUENY PHASE AMPS BAKUP FUSE BAKUP FUSE BAKUP FUSE SERIES 5 D & 0 50/60 & SHUNT 5 50/60 & , D SWITH ONLY 0 50/60 & /60 & ONSTRUTION TES - Pole -5 Poles; Up to urrent Poles, Voltage Pole -5 Poles; Up to urrent Poles, Voltage Pole Notes for Table : Requires branch circuit backup with a UL LISTED Type K5 or RK5 fuse rated 5A minimum and no more than times full load amp rating and not to exceed 5 amps. Table D: Lists UL Recognized, SA ertified configurations and performance capabilities as Protectors, Supplementary for Marine Electrical and Fuel Systems (Guide PEQZ, File E75596). Ignition Protected per UL 500. UL lassified Small raft Electrical Devices, Marine in accordance with ISO 886 (Guide UZMK, File MQ55) as Marine Supplementary Protectors. E-SERIES TABLE D: UL500 (MARINE IGNITION PROTETED) VOLTAGE URRENT INTERUPPTING RATING APAITY (AMPS) IRUIT MAX FULL WITHOUT ONFIGURATION RATING FREQUENY PHASE AMPS BAKUP FUSE 65 D SERIES 5 50 / 60 Ø / 60 Ø

87 E-Series General Specifications Electrical Maximum Voltage 600VA 50/60 Hz, 5VD (See Table A) urrent Ratings Standard current coils: 0.00, 0.50, 0.500,.00,.50, 5.00, 7.50, 0.0, 5.0, 0.0, 5.0, 0.0, 50.0, 60.0, 70.0 & 00 Amp. Auxiliary Switch Rating SPDT; 0.A 50VA,.0A 65VD; 0.5A 80VD, 0.A 5VA (with gold contacts). Insulation Resistance Minimum of 00 Megohms at 500 VD. Dielectric Strength UL, SA: 00 V 50/60 Hz for one minute between all electrically isolated terminals. E-Series ircuit Breakers comply with the 8mm spacing and 750V 50/60 Hz dielectric requirements from hazardous voltage to operator accessible surfaces, between adjacent poles and from main circuits to auxiliary circuits per Publications EN and VDE Resistance, Impedance Values from Line to Load Terminal - based on Series Trip ircuit Breaker. O H M S RESISTANE, IMPEDANE VALUES from Line to Load Terminals (Values Based on Series Trip ircuit Breaker) URRENT TOLERANE (AMPS) (%) ± 5% ± 5% ± 5% Mechanical Endurance Trip Free Trip Indication Physical 0,000 ON- 6 per minute; with rated urrent and Voltage. All E-Series ircuit Breakers will trip on overload, even when Handle is forcibly held in the ON position. The operating Handle moves positively to the position when an overload causes the breaker to trip. Number of Poles - 6 Mounting A " minimum spacing must be provided between the circuit breaker arc venting area on back connected E-Series circuit breakers and grounded obstructions. E- Series circuit breakers must be mounted on a vertical surface. onnectors, Box Type Front connected E-Series circuit breakers are supplied with box type pressure connectors that accept copper or aluminum conductors as follows: /0- opper, /0- Aluminum. Internal ircuit Series and Switch Only, (with or onfiguration without auxiliary switch). Shunt with current coils. Weight Approximately 5 grams/pole (Approximately 9 ounces/pole) Standard olors Housing-Black; Actuator - See Ordering Scheme. Environmental AMPERE RATING Pulse Tolerance urves Multiple of Rated urrent 5x x I r 60 Hz / ycle Inrush Pulse Tolerance Time Delay urves, & 6 (50 Amps Max.) Time Delay urves,, 6 (70 Amps Max.) t 6.67 Time in Milliseconds Multiple of Rated urrent x 0x I r 50 Hz / ycle Inrush Pulse Tolerance Time Delay urves, & 6 (50 Amps Max.) Time Delay urves,, 6 (70 Amps Max) 0.0 Time in Milliseconds t Designed and tested in accordance with requirements of specification MIL-PRF and MIL-STD-0 as follows: Shock Withstands 00 Gs, 6ms, sawtooth while carrying rated current per Method, Test ondition I. Vibration Withstands 0.060" excursion from 0-55 Hz, and 0 Gs Hz, at rated current per Method 0, Test ondition A. Moisture Resistance Method 06D, i.e., ten -hour + 5 to +65, 80-98% RH. Salt Spray Method 0, ondition A (90-95% 5% Nal Solution, 96 hrs). Thermal Shock Method 07D, ondition A (Five -55 to +5 to +85 to +5 ). Operating Temperature -0 to

88 E Series Actuator Poles ircuit E-Series Handle UL Recognized Ordering Scheme A B 0 50 A 5 Auxiliary Switch 6 Frequency & Delay 7 urrent Rating 8 Terminal 9 Actuator olor 0 Mounting/ Barriers Maximum Application Rating B Agency Approval SERIES E ATUATOR Handle A Handle, one per pole POLES One Two IRUIT A Switch Only (No oil) B Series Trip (urrent) Series Trip (Voltage) D Shunt Trip (urrent) 5 AUXILIARY SWITH 0 without Auxiliary Switch SPDT 0.0 Q.. Terminals SPDT 0.9 Solder Lug SPDT 0.0 Q.. Terminals (Gold ontacts) Three Four E F G 5 Five 6 Six Shunt Trip (Voltage) Relay Trip (urrent) Relay Trip (Voltage) 6 SPST 0.0 Q.. Terminals 7 SPST 0.0 Q.. Terminals (Gold ontacts) 8 SPST 0.87 Q.. Terminals 9 SPDT 0.87 Q.. Terminals 8 TERMINAL BAK ONNETED (FRONT MOUNTED ONLY) MAX. RATING 9 0- Stud (All Terminals) 50 A 9 /-0 Stud (All Terminals) 00 A A 9 M5 Stud (Line & Load) 50 A B 9 M6 Stud (Line & Load) 00 A FRONT ONNETED (BAK MOUNTED ONLY) MAX. RATING 0 Box Wire onnector (Line & Load) 00 A Box Wire onnector w/ Pressure Plate (Line & Load) 00 A 0- Screw (Line & Load) 50 A D M5 Screw (Line & Load) 50 A 5 0- Bus-Type Screw (Line), 0- Screw (Load) 50 A E M5 Bus-Type Screw (Line), 0- Screw (Load) 50 A Bus-Type Screw (Line), Box Wire onnector (Load) 00 A F 0- Bus-Type Screw (Line), Box Wire onnector w/ Pressure Plate (Load) 00 A 7 /-0 Screw (Line & Load) 00 A G M6 Screw (Line & Load) 00 A 8 /-0 Bus-Type Screw (Line), /-0 Screw (Load) 00 A H M6 Bus-Type Screw (Line), M6 Screw (Load) 00 A 9 0 /-0 Bus-Type Screw (Line), Box Wire onnector (Load) 00 A J /-0 Bus-Type Screw (Line), Box Wire onnector w/ Pressure Plate (Load) 00 A 6 FREQUENY & DELAY 0 D 50/60Hz, Switch Only 0 5 D Instantaneous D Short D Medium 6 D Long /60Hz Instantaneous 50/60Hz Short 50/60Hz Medium 6 50/60Hz Long 0 D, 50/60Hz Instantaneous D, 50/60Hz Short D, 50/60Hz Medium 6 D, 50/60Hz Long 6 50/60Hz Short, Hi-Inrush 6 50/60Hz Medium, Hi-Inrush 66 50/60Hz Long, Hi-Inrush 7 D, Short,Hi-Inrush 7 D,Medium, Hi-Inrush 76 D, Long, Hi-Inrush 9 6 D, 50/60Hz Short, Hi-Inrush 9 6 D, 50/60Hz Medium, Hi-Inrush 96 6 D, 50/60Hz Long, Hi-Inrush 7 URRENT RATING (AMPERES) OR VOLTAGE OIL (MIN. TRIP RATING, VOLTS) 5 A06 6 D, 5 D A65 65 D, 55 D J8 8 A, 0 A A D, 0 D B5 5 D, 00 D J65 65 A, 55 A A8 8 D, 5 D J06 6 A, 5 A K0 0 A, 65 A A D, 0 D J A, 0 A L0 0 A, 0 A A D, 5 D J8 8 A, 5 A A8 8 D, 0 D J A, 0 A TES VDE approval on -5 poles only. Standard multi-pole units identical poles except when specifying auxiliary switch - (see Note ). For mixed ratings, consult factory. Switch Only & Series Trip construction available w/either front or back connected terminals. Shunt construction available w/back connected terminals, (Terminal odes & ) only.ircuit odes B, & D are VDE approved. Switch Only construction: 0 amps or less select urrent Rating ode 60; -70 amps, select urrent Rating code 670; 7-00 amps, select urrent Rating ode 80; 0-5 amps Select urrent Rating ode 9. Switch Only is VDE approved only if tied to a protected pole. Auxiliary Switch available on Switch Only and Series Trip units. On multi-pole units, only one auxiliary switch is normally supplied mounted in the extreme right pole. Back mounted units require special mounting provisions when auxiliary switch is specified. VDE approval on Auxilary Switch odes 0,, & only ATUATOR OLOR & LEGEND Actuator olor Marking: Marking olor: olor: I-O ON- Dual White A B Black Black D White Red F G White Green H J White Blue K L 5 White Yellow M N 6 Black Gray P Q 7 Black Orange R S 8 Black 0 MOUNTING/BARRIERS BAK ONNETED (FRONT MOUNTED ONLY) Mounting Inserts A 6- B ISO M FRONT ONNETED (BAK MOUNTED ONLY) Back Mounting Foot Type Front Mounting Inserts (Optional Use) Short 6- D Short ISO M E Long 6- F Long ISO M MAXIMUM APPLIATION RATING 5 A 65 VD, 0 A B 5 VD, 0 A 0/0 VA, 00 A D 0 VA, 00 A L E 6 77/80 VA, 00 A T F 77 VA, 00 A G 6 H 6 J 6 W 6 AGENY APPROVAL B UL 077 / UL508 Recognized & SAertified D UL 077 Recognized, SAertified, & VDE ertified 600 VA, 00 A 80 VA, 00 A 5 VA, 00 A 60 VD, 00 A 5 VD/0 VA, 00 A 5 VD/5 VA, 00 A 5 Voltage Trip oils are not rated for continuous duty. Available only with Frequency & Delay odes 0 & 0.Series Trip construction with a voltage coil s VDE approved only if tied to a protected pole. 6 Frequency & Delay odes 9,9 & 96 are not VDE approved. 7 urrent oil Ratings ams are VDE approved. 8 5 A rating (ode 9) available as a Switch Only (ircuit ode A), rated 5 VD (ode B). 9 An Anti-Flash Over Barrier is supplied between poles on multi-pole units with 0- (Terminal ode ). /-0 (ode ), M5 (ode A), and M6 (ode B) terminals per UL requirement. 0 Box Wire onnector will accept # through 0 AWG. copper wire or # through 0 AWG. aluminum wire. Box Wire onnector with Pressure Plate for stranded wire, consult factory for details. Terminal odes A,B,D,E,G & H are not VDE approved. VDE approvals require Dual (I-O, ON-) or I-O markings on all handles. Back Mounted breakers can also be front mounted by utilizing the proper front panel mounting inserts normally supplied. However, terminal connections must be made prior to mounting. 5 Application ratings B,D,J,T & W are available with VDE. 6 5, 80 & 600 VA ratings require or pole break Ø and pole break Ø.

89 E Series E-Series Handle UL Listed Ordering Scheme A B 0 50 A Actuator Poles ircuit 5 Auxiliary Switch 6 Frequency & Delay 7 urrent Rating 8 Terminal 9 Actuator olor 0 Mounting/ Barriers Maximum Application Rating Agency Approval SERIES E ATUATOR Handle A Handle, one per pole POLES One Two 6 FREQUENY & DELAY 0 5 D Instantaneous D Short D Medium 6 D Long /60Hz Instantaneous 50/60Hz Short 50/60Hz Medium 6 50/60Hz Long D, 50/60Hz Short D, 50/60Hz Medium 6 D, 50/60Hz Long Three Four 7 URRENT RATING (AMPERES) OR VOLTAGE OIL (MIN. TRIP RATING, VOLTS) 5 A06 6 D, 5 D A65 65 D, 55 D A D, 0 D B5 5 D, 00 D A8 8 D, 5 D J06 6 A, 5 A A D, 0 D J A, 0 A A D, 5 D J8 8 A, 5 A A8 8 D, 0 D J A, 0 A 5 Five 6 Six IRUIT B Series Trip (urrent) Series Trip (Voltage) 5 AUXILIARY SWITH 0 without Auxiliary Switch SPDT 0.0 Q.. Terminals SPDT 0.9 Solder Lug SPDT 0.0 Q.. Terminals (Gold ontacts) 6 SPST 0.0 Q.. Terminals 7 SPST 0.0 Q.. Terminals (Gold ontacts) 8 SPST 0.87 Q.. Terminals 9 SPDT 0.87 Q.. Terminals 6 50/60Hz Short, Hi-Inrush 6 50/60Hz Medium, Hi-Inrush 66 50/60Hz Long, Hi-Inrush 7 D, Short,Hi-Inrush 7 D,Medium, Hi-Inrush 76 D, Long, Hi-Inrush 9 6 D, 50/60Hz Short, Hi-Inrush 9 6 D, 50/60Hz Medium, Hi-Inrush 96 6 D, 50/60Hz Long, Hi-Inrush J8 8 A, 0 A J65 65 A, 55 A K0 0 A, 65 A L0 0 A, 0 A 8 TERMINAL 7 BAK ONNETED (FRONT MOUNTED ONLY) MAX. RATING 8 0- Stud (All Terminals) 50 A 8 /-0 Stud (All Terminals) 00 A FRONT ONNETED (BAK MOUNTED ONLY) MAX. RATING 9 Box Wire onnector (Line & Load) 00 A 0 Box Wire onnector w/ Pressure Plate (Line & Load) 00 A 0- Screw (Line & Load) 50 A 5 0- Bus-Type Screw (Line), 0- Screw (Load) 50 A Bus-Type Screw (Line), Box Wire onnector (Load) 00 A F 0 0- Bus-Type Screw (Line), Box Wire onnector w/ Pressure Plate (Load) 00 A 7 /-0 Screw (Line & Load) 00 A 8 /-0 Bus-Type Screw (Line), /-0 Screw (Load) 00 A 9 9 /-0 Bus-Type Screw (Line), Box Wire onnector (Load) 00 A J 0 /-0 Bus-Type Screw (Line), Box Wire onnector w/ Pressure Plate (Load) 00 A 9 ATUATOR OLOR & LEGEND Actuator olor Marking: Marking olor: olor: ON- Dual White B Black Black D White Red G White Green J White Blue L 5 White Yellow N 6 Black Gray Q 7 Black Orange S 8 Black 0 MOUNTING/BARRIERS BAK ONNETED (FRONT MOUNTED ONLY) Mounting Inserts A 6- B ISO M FRONT ONNETED (BAK MOUNTED ONLY) Back Mounting Foot Type Front Mounting Inserts (Optional Use) Short 6- D Short ISO M E Long 6- F Long ISO M MAXIMUM APPLIATION RATING B 5 VD, 00A 0/0 VA, 00A D 0 VA, 00A AGENY APPROVAL UL 89 Listed & SAertified F UL 89 Listed, SAertified, & VDE ertified TES Standard multi-pole units identical poles except when specifying auxiliary switch - (see Note ). For mixed ratings, consult factory.vde approval on -5 poles only. Series Trip construction available w/either front or back connected terminals. Series Trip construction with a voltage coil is not available as a single pole unit and must be tied to a protected pole. On multi-pole units, only one auxiliary switch is normally supplied mounted in the extreme right pole per Figure A. Back mounted units require special mounting provisions when auxiliary switch is specified. VDE approval on auxilary switch codes 0,, & only. 5 Voltage Trip oils are not rated for continuous duty. Available only with Frequency & Delay odes 0 & 0. 6 Frequency & Delay odes 9, 9 & 96 are not VDE approved. 7 urrent Ratings under 0.00 amps are not VDE approved. 8 An Anti-Flash Over Barrier is supplied between poles on multi-pole units with 0- Stud (Terminal ode ) or /-0 Stud (ode ) terminals per UL requirement. 9 Box Wire onnector will accept # through 0 AWG. copper wire or # through 0 AWG. aluminum wire. 0 Box Wire onnector with Pressure Plate for stranded wire, consult factory for details. Back Mounted breakers can also be front mounted by utilizing the proper front panel mounting inserts normally supplied. However, terminal connections must be made prior to mounting. VDE approval required dual (I-O, ON-) markings on all handles. Not available with VDE approval. 87

90 E-Series Handle & Rocker ircuit & Terminal Diagrams SERIES TRIP ( TERMINALS) SWITH ONLY ( TERMINALS) SERIES TRIP W/AUX SWITH (5 TERMINALS) SHUNT TRIP ( TERMINALS) RELAY TRIP ( TERMINALS) TYPIAL TERMINAL.600 [9.] TYP BARRIER SEE TE TERMINAL SEE TE TERMINAL.000[5.0] ON I BAK ONNETED TERMINALS.550 [90.7] TYP 5.5 [0.8] TYP N.50 [.95] AUX. SWITH TERMINALS SHUNT TRIP TERMINAL.550 [90.7] TERMINAL RELAY TERMINALS.550 [90.7] O.75 [.56].50 [.75].50 [.75].00 [5.05].750 [9.05].750 [9.05].5 [6.07].60 [66.0] TYP SEE TE TYP.750 [9.05] TYP TERMINAL TERMINAL STUD TERMINALS ARE SUPPLIED WITH.60 [66.0].87 [.75] HEX NUTS AND FLAT WASHERS / TERMINALS.60 [66.0].87 [.75].60 [66.0] TYP.0 [0.55].0 [0.55].5 [.8].5 [.8].650 [6.5].90 [9.9] FRONT ONNETED TERMINALS.85 [.].85 [.] BOX TYPE WIRE ONNETORS.87 [.75] BUS TYPE SREW TERMINALS TYPIAL TERMINAL BARRIER (ON BAK ONNETED BREAKERS ONLY) AUXILIARY SWITH TERMINALS.05 DIA [Ø.0].87 [7.9].0 [.80].6 [.0].0 [.80].087 [.0].070 DIA [Ø.80] TAB (Q..).0 X.00 SOLDER TYPE (.0 x.00) POLE POLE POLE MULTI-POLE IDENTIFIATION SHEME TABLE A TIGHTENING TORQUE SPEIFIATIONS THREAD SIZE TERMINAL TYPE #6- [M] HARDWARE #0- THD TERMINAL SREW /-0 THD TERMINAL SREW #0- STUDS /-0 STUDS BOX WIRE ONNETOR WIRE SIZE ALL ALL ALL ALL -0 AWG 8 AWG 6- AWG -/0 AWG TORQUE 7-9 IN-LBS [ NM] 5-0 IN-LBS [.7-. NM] 0-5 IN-LBS [.-.0 NM] 5-0 IN-LBS [.7-. NM] 0-5 IN-LBS [.-.0 NM] 5 IN-LBS [.0 NM] 0 IN-LBS [.5 NM] 5 IN-LBS [5. NM] 50 IN-LBS [5.7 NM] All dimensions are in inches [millimeters]. Tolerance ±.05 [.8] unless otherwise specified amps: 0- & M5 Studs.65 ±.06 /5.88 ±.57 long. 5-0 amps: /-0 & M6 Studs.750 ±.06 /9.05 ±.57 long. 88

91 E-Series Handle (Back onnected ) Form & Fit Drawings MOUNTING INSERTS: LEARANE AREA SEE TE #6- [M] THREAD x.0 [5.59] MIN. DEEP ( PLS)/POLE TYPIAL ANTI-FLASHOVER BARRIER.00 [76.].06 [.57].06 [6.06].750 [69.85].50 [57.5] ON I.56 [5.76] 5.5 [0.8] [0.65].550 [90.7] TYP.75 [.9] 5.5 [8.58] O TYPIAL OPTIONAL "ON-, I-O" LEGEND.750 [9.05] TYP.69 [7.].65 [6.5].06 [6.06].60 [66.0] SEE TE TYP..0 [5.59].600 [9.] PANEL UTOUT DETAIL 6.76 [59.0] MAX. 5.0 [.85] MAX..85 [06.] MAX..8 [79.70] MAX. 6 POLES 5 POLES POLES POLES POLES.09 [5.5] MIN [59.0] MIN. 5.0 [.85] MIN..85 [06.] MIN..8 [79.70] MIN..09 [5.5] MAX..06 [6.06] TYP POLES.0 [6.50] MIN..06 [6.06] MULTI-POLE UNITS ARE ASSEMBLED AT FATORY WITH OMMON HANDLE TIE ±.005 [±.].750 [69.85] ±.005 [±.].85 [58.05] ±.005 [±.]. [5.90] ±.005 [±.].50 [.0] ±.005 [±.].56 DIA.[Ø.96] ( PLS) TYP PER POLE ±.005 [±.].06 [6.06] TYP / -0 stud terminal in Series Trip circuit configuration shown. A min spacing must be provided between the circuit breaker arc venting area of back connected E-Series circuit breaker and grounded obstructions. All dimensions are in inches [millimeters]. Tolerance ±.00 [.5] unless otherwise specified. 5 ircuit breakers must be mounted on vertical surface. 89

92 E-Series Handle (Front onnected) Form & Fit Drawings MOUNTING INSERTS: #6- [M] THREAD x.0 [5.59] MIN. DEEP ( PLS)/POLE.60 [66.0] LONG MOUNTING FOOT SHORT MOUNTING FOOT SEE TE.06 [6.06].00 [5.08].0 [5.59].65 [6.5].5 [.8].00 [5.08].5 [.8].5[.0].56 [5.76].78 [.] REF.50 [6.5] REF.750 [69.85].750 [0.65] +.05 [.8] [-.].50 [57.5] ON I [.] [6.8].78 [.].5 [.8].75 [60.5] O.5 [8.58] TYPIAL OPTIONAL "ON-, I-O" LEGEND.75 [.9].0 [5.59] REF..500 [.70].69 [7.].06 [6.06] MTG. SLOT LEARANE FOR #8-[M] SREW ( PLS).0 [5.59] 6.76 [59.0] MIN. 5.0 [.85] MIN. PANEL UTOUT DETAIL.85 [06.] 6 POLES 6.76 [59.0] MIN..8 [79.70] MAX. 5 POLES 5.0 [.85] MIN..09 [5.5] MAX..06 [6.06].06 [6.06] TYP POLES POLES POLES.09 [5.5] MIN..85 [06.] MIN..8 [79.70] MIN. POLE.0 [6.50] MIN. MULTI-POLE UNITS ARE ASSEMBLED AT FATORY WITH OMMON HANDLE TIE ±.005 [±.].750 [69.85] ±.005 [±.].85 [58.05] ±.005 [±.]. [5.90] ±.005 [±.].59 [.0] ±.005 [±.].56 [.96] DIA ( PLS) TYP PER POLE ±.005 [±.].06 [6.06] TYP All dimensions are in inches [millimeters]. Tolerance ±.00 [.5] unless otherwise specified. Box wire connector terminal in Series Trip circut configuration shown. ircuit breakers must be mounted on vertical surface. 90

93 F-Series General Specifications F-Series breakers are available up to 700A, and are also available with a 5 millivolt metering shunt construction. This optional construction provides a safe method for monitoring current flowing through the breaker by simply connecting a meter with light gauge wire to the appropriate terminals located on the shunt housing at the rear of the breaker. You can customize the application by measuring and displaying percentage of current, watts or safe/danger zones. Agency ertifications UL Listed UL Standard 89A ircuit Breakers, Molded ase, (Guide DIVQ7, File E9899) TUV ertified EN6097-, Low Voltage Switchgear and ontrol Gear. UL Standard 89 omplies with the requirements of SA Standard for Molded ase ircuit Breakers, AN/SA -. No M Electrical Table A: Lists UL Listed (89),( AN/SA -. No. 5.-M) TUV ertified configuration and performance capabilities as a Molded ase ircuit Breaker. F-SERIES TABLE A: UL89 BRANH IRUIT BREAKER URRENT VOLTAGE RATING INTERRUPTING APAITY (AMPS) IRUIT MAX FULL UL TUV ONFIGURATION RATING FREQUENY PHASE AMPS - POLES or POLES SERIES 5 D ,000 5,000 Table B: Lists UL Listed configurations and performance capabilities as ircuit Breakers for use in ommunications Equipment (Guide DITT, File E8995), under UL89A. F-SERIES TABLE B: PARALLEL POLE ONSTRUTION UL89A FOR OMMUNIATIONS EQUIPMENT URRENT VOLTAGE RATING INTERRUPTING IRUIT MAX GENERAL APAITY ONFIGURATION RATING FREQUENY PHASE PURPOSE AMPS (AMPS) SERIES 5 D ,000 9

94 F-Series General Specifications Electrical Mechanical Maximum Voltage 5VD urrent Ratings Standard current coils: 00, 5, 50, 75, 5, 50 amps. 00, 50, 00, 500, 600, 700 amps available as parallel pole construction. Auxiliary Switch Rating SPDT; 0. 50VA,.0 65VD, VD 0. 5VA (with gold contacts). Insulation Resistance Minimum: 00 Megohms at 500 VD Dielectric Strength 960 VA, 50/60 Hz for one minute between all electrically isolated terminals, except 500 VA for one minute between alarm/aux. switch and main terminals with contacts in open and closed position. F-Series circuit breakers comply with the 8mm spacing & 750VA 50/60 Hz dielectric requirements from hazardous voltage to operator accessible surfaces, between adjacent poles and from main circuits to auxilary circuits per Publications EN and VDE Resistance, Impedance Values from Line to Load Terminal - based on Series Trip ircuit 0.00 URRENT (AMPS) TOLERANE (%) ± 50% Endurance Trip Free Trip Indication Physical 000 ON- operations with rated urrent & Voltage & 000 operations with no load (8000 operations 5 per minute. Parallel Pole construction: 000 operations with rated urrent and 5 per minute. All F-Series ircuit Breakers will trip on overload, even when the actuator is forcibly held in the ON position. The operating actuator moves positively to the position when an overload causes the circuit breaker Number of Poles - Poles Note: Ratings over 50 Amps only available with parallel pole. Internal ircuit onfig. Series, (with or without auxiliary switch), Switch Only (with or without auxiliary switch). Available Accessories Factory installed: D urrent Metering Shunt (5 Weight Varies depending on construction. onsult factory. Standard olors Housing - Black; Actuator- Black or White with contrasting ON- leg- Environmental O 9 H M S AMPERE RATING 700 Breaker. Designed and tested in accordance with requirements of specification MIL-PRF-5569 & MIL-STD-0 as follows: Shock Withstands 00 Gs, 6ms, sawtooth while carrying rated current per Method, Test ondition I. Instantaneous and ultra-short curves 90% of rated current. Vibration Withstands 0.060" excursion from 0-55 Hz, and 0 Gs Hz, at rated current per Method 0, Test ondition A. Instantaneous and ultrashort curves tested at 90% of rated current. Moisture Resistance Method 06D; ten -hour + 5 to +65, 80-98% RH , 85% RH. Salt Spray Method 0, ondition A (90-95% 5% Nal Solution, 96 hrs). Thermal Shock Method 07D, ondition A (Five -55 to +5 to +85 to +5 ).

95 F-Series Handle Ordering Scheme F Series A B 0 80 A B Actuator Poles ircuit 5 Auxiliary/ Alarm Switch 6 Frequency & Delay 7 urrent Rating 8 Terminal 9 Actuator olor 0 Mounting Max. App. Rating G Agency Approval SERIES F ATUATOR A Handle, one per pole S Mid-Trip Handle, one per pole T Mid-Trip Handle, one per pole & Alarm Switch POLES One Two Three IRUIT A Switch Only (No oil) B Series Trip (urrent) Series Trip (Voltage) Parallel Pole onstruction: M, Series Trip (urrent) with Metering Shunt N, Switch Only with Metering Shunt P Series Trip (urrent) Switch Only Q 7 URRENT RATING (AMPERES) OR VOLTAGE OIL (VOLTS, MIN. TRIP RATING) 7 A06 6 D, 5 D A D, 0 D A D, 0 D A D, 5 D A8 8 D, 5 D A8 8 D, 0 D A65 65 D, 55 D B5 5 D, 00 D J06 6 A, 5 A 8 TERMINAL Back onnected (Front Mounted Only) Max Rating 9 /8-6 Stud 50A /8-6 Screw, Line & Load 700A 5 /8-6 Short Stud 50A Front onnected (Back Mounted Only) Max Rating Box Wire onnector, Line & Load 700A /8-6 Screw, Line & Load 700A 5 AUXILIARY/ALARM SWITH 5 0 w/o Aux Switch S.P.D.T., 0.0 Q.. Term. S.P.D.T., 0.9 Solder Lug S.P.D.T., 0.0 Q.. Term. (Gold ontacts) 5 S.P.S.T., 0.09 Q.. Term. (Gold ontacts) 6 S.P.S.T., 0.9 Solder Lug 7 S.P.S.T., 0.0 Q.. Term.(Gold ontacts) 6 FREQUENY & DELAY 0 D 50/60Hz, Switch Only 0 7 D Instantaneous D Ultra Short 8 S.P.S.T., 0.87 Q.. Terminals 9 S.P.D.T., 0.87 Q.. Terminals. A 6 S.P.S.T., 0.09 Round Q Terminals. B 6 S.P.D.T., 0.09 Round Q.. Terminals. D Short D Medium 6 D Long 9 ATUATOR OLOR & LEGEND, Actuator: Marking: Marking olor: I-O ON- Dual White A B Black Black D White 0 MOUNTING Front Mounting Inserts Back Mounting Inserts A 0-0- screw clearance holes B ISO M5 0- screw clearance holes MAXIMUM APPLIATION RATING Voltage urrent B 5 VD 700A AGENY APPROVAL A No approvals G UL 89 Listed & UL ertified J UL 89 Listed, UL ertified & TUV ertified T UL89A (Telecom) Listed For 00 to 50 amps, select urrent ode 85. For amps, select urrent ode 80. For amps, select urrent ode 870. Available with Frequency and Delay code 0 only, and are not rated for continuous duty. Delay 0 is only available with voltage coils. odes M, N, P & Q (Parallel Poles) are supplied with factory installed Bus Bar on Line and Load. Metering terminals are female pin type, ref. Molex part number , model 89- T. 5 Auxiliary Switch breakers are only available with Series Trip and Switch Only circuits. On multi-pole breakers, one Auxiliary Switch is supplied, mounted in the extreme right pole per figure A. Back-Mounted breakers require special mounting provisions when an Auxiliary Switch is specified. 6 Available with parallel pole construction (circuit codes P and Q, and breakers with circuit codes M and N). 7 Frequency and delay code 0 is only available with voltage coils. Voltage oils are not rated for continuous duty. 8 Ratings over 50 amps are only available with Agency Approval code T (UL89A) and are Parallel Pole configuration (circuit codes M, N, P and Q.) amp ratings are available on two pole breakers amp ratings are available on three pole breakers. 9 Per UL requirement, an Anti-Flash Over Barrier is supplied between poles on multipole breakers with /8-6 stud terminals (Terminal ode ) 0 Front connected breakers can also be front mounted by utilizing the supplied front panel mounting inserts.terminal connections must be made before mounting. Box Wire connector will accept #6 through 50 MM copper wire. Agency codes G & T must have ON- or dual legends. Agency code J must have dual legend. Other colors available. onsult factory. 9

96 F-Series Handle ircuit & Terminal Diagrams F SERIES N-PARALLEL POLE ONSTRUTION: IRUIT BREAKER PROFILE.965 [75.].8 [.7] ANSI IRUIT SHEMATI IE SWITH ONLY ( OIL) (NETZ) IRUIT ODE AUX SWITH ODE IRUIT SHEMATI ANSI IE SWITH TRIP (NETZ) () IRUIT ODE AUX SWITH ODE SERIES TRIP ( TERM'S.) 5.99 [5.7] A 0 I > B 0 (LAST) (LAST) SERIES TRIP W/AUX. SWITH (5 TERM'S.) N.7 [69.]. [5.6].96 [6.9] SWITH ONLY ( OIL) WITH AUXILIARY SWITH (NETZ) A 5 9 SERIES TRIP WITH AUXILIARY SWITH STD. AUX SWITH (NETZ) () STD. AUX SWITH B [5.] N N (LAST) N ALARM SWITH I > (LAST) N ALARM SWITH TERMINAL DETAILS BAK ONNET /8-6 THREADED HOLE.569 [.5].098 [.9].06 [5.80].8 [.].56 [.68]. [.87] SHORT STUD ODE 5 /8-6 THREADED STUD ODE.06 [5.80].57 [.60] /8-6 THREADED HOLE ODE FRONT ONNET /8-6 THREADED HOLE.6 [0.8] BOX LUG AEPTS WIRE SIZE #6 TO 50 MM.675 [.5].75 [9.8] BOX WIRE ONNETOR /8-6 THREADED HOLE ODE All dimensions are in inches [millimeters]. Tolerance ±.05 [.8] unless otherwise specified. 9

97 F-Series Handle ircuit & Terminal Diagrams F-SERIES PARALLEL POLE ONSTRUTION: IRUIT BREAKER PROFILE IRUIT SHEMATI ANSI IE SWITH ONLY ( OIL) IRUIT ODE AUX SWITH ODE IRUIT SHEMATI ANSI SERIES TRIP IE IRUIT ODE AUX SWITH ODE (NETZ) (NETZ) () SERIES TRIP ( TERM'S.) A 0 B 0 I > (LAST) (LAST) SERIES TRIP W/AUX. SWITH (5 TERM'S.).7 [9.76] TYP.5 [8.50].7 [.].80 [.9] TYP.599 [9.] N MALE ALARM OR AUX. SW. TERMINALS MOLEX P/N [6.0] SWITH ONLY ( OIL) WITH ALARM OR AUX. SWITH N (NETZ) N (LAST) A B SERIES TRIP WITH ALARM OR AUX. SWITH STD. AUX SWITH N ALARM SWITH (NETZ) () STD. AUX SWITH I > (LAST) N ALARM SWITH B B SERIES TRIP W/METERING SHUNT ( TERM'S.).7 [.] (FOR 00-5 AMPS DIM =.000) M FEMALE METERING SHUNT TERMINALS MOLEX P/N SWITH ONLY ( OIL) WITH METERING SHUNT SHUNT METER METER (NETZ) () METER SHUNT (NEBENSHLUSS) METER N 0 SERIES TRIP URRENT OIL, WITH METERING SHUNT SHUNT METER METER (NETZ) () METER SHUNT (NEBENSHLUSS) METER M 0.0 [6.57] M (LAST) I > (LAST).9 [79.] RELAY TRIP ( TERM'S.) SWITH ONLY WITH ALARM OR AUX. SWITH AND METERING SHUNT (NETZ) () SERIES TRIP WITH ALARM OR AUX. SWITH AND METERING SHUNT (NETZ) () METER METER METER METER N A M A METER ALARM/ AUX. SWITH METER SHUNT SHUNT SHUNT SHUNT METER METER METER METER (LAST) I > (LAST) All dimensions are in inches [millimeters]. Tolerance ±.05 [.8] unless otherwise specified. 95

98 F-Series Handle ircuit & Terminal Diagrams TERMINAL DETAILS BAK ONNET.750 [9.05].65 [.5].7 [9.77] /8-6 THREADED HOLE ODE FRONT ONNET.750 [9.05] BOX LUG AEPTS WIRE SIZE #6 TO 50 MM.96 [7.99]. [6.] BOX WIRE ONNETOR /8-6 THREADED HOLE ODE All dimensions are in inches [millimeters]. Tolerance ±.05 [.8] unless otherwise specified. 96

99 F-Series Handle Form & Fit Diagrams SERIES TRIP BAK ONNET (STUD TERMINALS SHOWN). [.87].500 [8.].968 [75.8].5 [.65] #0- (M5) THREAD x.00 DEEP ( PLS/POLE).566 [.7].00 [0.6].87 [6.0] ON I.56 [.5] 7.5 [80.98].8 [7.] MID- TRIP 5. [58.7] [5.0] 5 O.06 [5.7].000 [76.0].500 [.0] MULTIPOLE SERIES TRIP, SHOWING TERMINAL BARRIER.50 [.75]. [5.8] BARRIERS.06 THIK TYP.56 [8.50] All dimensions are in inches [millimeters]. Tolerance ±.05 [.8] unless otherwise specified. 97

100 F-Series Handle Form & Fit Diagrams SERIES TRIP FRONT ONNET (BOX LUG TERMINALS SHOWN) LEARANE HOLES FOR #0- MOUNTING SREWS.88 [97.].507 [8.9].757 [9.].55 [.68].05 [78.58].0 [5.5] PER POLE.656 [.06].8 [59.].8 [7.8]. [.87].50 [6.6] PANEL UTOUT DETAIL.500 [8.0] WIRE RANGE #6 AWG TO 50 MM.65 [.96] All dimensions are in inches [millimeters]. Tolerance ±.05 [.8] unless otherwise specified. 98

101 F-Series Handle Form & Fit Diagrams.90 [.87].68 [.60].5 [.0] 0.99 [6.].09 [78.5].87 [.7]. [59.8].587 [0.0].8 [.8].968 [9.98].50 [6.5].7 [8.87].96 [7.99] F SERIES AMPS SHOWING METERING SHUNT AND BOX LUG ONNETORS. F-Series breakers are available up to 700A, and are also available with a 5 millivolt metering shunt construction. This optional construction provides a safe method for monitoring current flowing through the breaker by simply connecting a meter with light gauge wire to the appropriate terminals located on the shunt housing at the rear of the breaker. You can customize the application by measuring and displaying percentage of current, watts or safe/danger zones. All dimensions are in inches [millimeters]. Tolerance ±.05 [.8] unless otherwise specified. 99

102 F-Series Handle Form & Fit Diagrams "A".500 [8.0] 0.99 [6.].0 [8.8] [6.0].09 DIA. PLUG-IN TERMINALS FOR AUX. OR ALARM SWITH AND/OR METERING SHUNT ONNETIONS. SEE IRUIT AND TERMINAL DRAWINGS FOR DETAILS..80 [.9] ( PL).60 [6.5].7 [.] "B" F-SERIES PARALLEL POLE AMPS SHOWING FRONT ONNET SREW TERMINALS F-SERIES PARALLEL POLE WIDTH DIMENSIONS TIGHTENING TORQUE SPEIFIATIONS URRENT RATING AMPS AMPS DIM. "A".75 [60.].875 [98.] DIM. "B".000 [76.0].500 [.0] THREAD SIZE/ TERMINAL TYPE 0- MOUNTING HARDWARE M5 MOUNTING HARDWARE /8-6 SREW & STUD TERMINALS BOX WIRE ONNETOR TORQUE 0- IN-LBS [.-. NM] 8-0 IN-LBS [0.9-. NM] 0-0 IN-LBS [ NM] 80 IN-LBS [0. NM] All dimensions are in inches [millimeters]. Tolerance ±.05 [.8] unless otherwise specified. 00

103 PD-Series General Specifications SmartGuard is an equipment ground fault protection device that combines hydraulic/magnetic circuit breaker and overload and short circuit protection and ground fault protection. This breaker senses and guards against faults to ground using a state of the art integrated circuit. This technology detects faults and when a fault occurs, the breaker trips and an LED illuminates. The LED gives a clear indication that the trip occurred as a result of leakage. This protection helps prevent serious equipment damage and fire. Agency ertifications UL Recognized UL Standard 077 UL Standard 9 omponent Recognition Program as Equipment Leakage ircuit Interrupter and, Protectors, Supplementary (FTTJ, File E7750). Tested as Ground Fault ircuit Interrupters for Equipment Protection. SA ertified TUV ertified omponent Equipment Leakage urrent Interrupter with Supplementary Protector, under lass.,no. -M9, FIle LR IE 97- and appendix B: ircuit Breakers incorporating Residual urrent Protection. omplies with waveform requirements of IE 008-, Type A. Electrical Table A: Lists UL Recognized & SA ertified configurations and performance capabilities as a omponent Supplementary Protector. PD-SERIES TABLE A: OMPONENT SUPPLEMENTARY PROTETOR & EARTH LEAKAGE URRENT INTERRUPTER INTERRUPTING LEAKAGE VOLTAGE URRENT RATING APAITY (AMPS) URRENT FULL GENERAL UL / SA MUST - TRIP IRUIT MAX PURPOSE WITHOUT RATING ONFIGURATION RATING FREQUENY PHASE AMPS AMPS BAKUP FUSE (MILLIAMPS) 0/08 50/ SERIES 0/08 50/ / Y 50/ Table B: Lists TUV ertified configurations and performance capabilities as a ircuit breaker incorporating residual current protection. PD-SERIES TABLE B: IRUIT BREAKER WITH RESIDUAL URRENT PROTETION URRENT LEAKAGE VOLTAGE INTERRUPTING APAITY (AMPS) RATING URRENT FULL MUST - TRIP ULTIMATE S/ SERVIE S/ RESIDUAL S/ IRUIT MAX RATING BREAKING BREAKING MAKE/BREAK ONFIGURATION RATING FREQUENY PHASE AMPS (MILLIAMPS) APAITY (lcu) APAITY (lcs) URRENT (l m) / mA SERIES / mA /60 -Y mA / mA

104 PD-Series Equipment Leakage General Specifications Electrical Mechanical Maximum Voltage A, 80 WYE/77 VA, 50/60 Hz Standard urrent Ratings.00,.50, 5.00, 7.50, 0.0, 5.0, 0.0, 5.0, 0.0, 5.0, 0.0 & 50.0 amps. For other ratings, consult factory. Insulation Resistance Minimum of VD. Dielectric Strength 960 VA, 60 Hz for one minute between all electrically isolated terminals. Resistance, Impedance from Line to Load Terminal (Values Based on Series Trip ircuit O H M S AMPERE RATING Leakage To Ground 00 URRENT TOLERANE (AMPS) (%) ± 5% ± 5% ± 5% Endurance Trip Free Physical 0,000 ON- 6 per minute; with rated current and voltage. All SmartGuard equipment leakeage circuit breakers will trip on overload or leakage to ground, even when actuator is forcibly held in the ON Number of Poles, & Length (included switched or unswitched neutral). inches ( 06.7 mm) Width -pole:.0 inches (76. mm) -pole:.75 inches (95. mm) -pole:.5 inches (. mm) Depth.5inches (6.5mm). Weight: -pole 6.0 oz. (5.6 gm) -pole:. oz. (606.7 gm) -pole: 6.9 oz. (76.6 gm) Standard olors Housing - gray; Actuator - black, red, or white Mounting Front Panel or Standard 5mm Symmetrical DIN Rail (5 x 7.5 or 5 x 5mm per DIN EN500). Termination Box Lug Standard Must Trip Leakage urrent Ratings 7, 0, 5, 0, 50 & 00 milliamps. For other ratings, consult factory. Trip Time 00 ms 00%, 0ms 500% of must trip leakage current. Test Button On breaker face above actuator. Leakage Trip Indicator Red LED on breaker face above Environmental Operating Temperature +0 to +50 0

105 PD Series PD-Series Equipment Leakage Ordering Scheme R B 650 B A Voltage/ Poles ircuit Frequency & Delay 5 urrent Rating 6 7 Equipment Terminal Leakage - Trip urrent 8 Actuator 9 Actuator olor 0 Mounting Agency Approval SERIES PD SYSTEM VOLTAGE/POLES System Voltage Poles A 0VA Ø One plus unswitched neutral B 0/0 VA Ø Two 0/08 VA Ø, Two plus unswitched neutral 0/0 VA Ø D 0/08 VA Ø, Two plus switched neutral 0/0 VA Ø E 08/0 VA Ø Three F 08/0 VA Ø Three plus unswitched neutral G 08/0 VA Ø Three plus switched neutral P 80Y VA Ø Three Q 80Y VA Ø Three plus unswitched neutral R 80Y VA Ø Three plus switched neutral 6 EQUIPMENT LEAKAGE - TRIP URRENT (milliamps) B 7 D 5 F 50 0 E 0 G 00 7 TERMINAL Front onnected Box Lug with Pressure Plate 8 ATUATOR A Handle B Handle. with handleguard 9 ATUATOR OLOR & LEGEND Actuator olor Marking: Marking olor: olor: I-O ON- Dual White A B Black Black D White Red E F White IRUIT B Series Trip (urrent) FREQUENY & DELAY 0 50/60Hz Instantaneous 50/60Hz Short 5 URRENT RATING (AMPERES) /60Hz Medium 6 50/60Hz Long MOUNTING Threaded Insert 6- x 0.95 inches Threaded Insert ISO M x 6.5 mm AGENY APPROVAL UL Recognized & SAertified U TUV ertified Units with a switched or unswitched neutral connection are the same size as a unit with an additional breaker pole (e.g. a -pole unit with a switched or unswitched neutral is the same physical size as a -pole unit.) Switched neutral poles contain the same overcurrent protection as the other poles. The leakage currents shown will cause the breaker to trip (must-trip current). The musthold current is 67% of the must-trip current. All breakers are front panel mountable using screw size shown. Breakers may also be mounted on either 5mm x 7.5mm or 5mm x 5mm symmetrical DIN rail. TUV certifed units must have I-O or Dual legends. 0

106 PD-Series ircuit & Terminal Diagrams IRUIT SHEMATIS -POLE IRUIT PDA -POLE IRUITS PDE & PDP TRIPPED DUE TO EARTH LEAKAGE INDIATOR SOLID STATE IRUITRY SENSOR P(L) (N) TEST TRIPPED DUE TO EARTH LEAKAGE INDIATOR SOLID STATE IRUITRY SENSOR P(L) P(L) P(L) TEST TRIP MEHANISM TRIP MEHANISM -POLE IRUITS PDB P(L) P(L) P(N) P(L) PDF & PDQ (WITH UNSWITHED NEUTRAL) P(L) P(L) P(L) (N) SOLID STATE IRUITRY SOLID STATE IRUITRY TRIPPED DUE TO EARTH LEAKAGE INDIATOR SENSOR TEST TRIPPED DUE TO EARTH LEAKAGE INDIATOR SENSOR TEST TRIP MEHANISM TRIP MEHANISM PD (WITH UNSWITHED NEUTRAL) P(L) P(L) (N) SOLID STATE IRUITRY PDG & PDR (WITH SWITHED NEUTRAL) SOLID STATE IRUITRY P(L) P(L) P(L) (N) TRIPPED DUE TO EARTH LEAKAGE INDIATOR SENSOR TEST TRIPPED DUE TO EARTH LEAKAGE INDIATOR SENSOR TEST TRIP MEHANISM TRIP MEHANISM PDD (WITH SWITHED NEUTRAL) P(L) P(L) (N) SOLID STATE IRUITRY TRIPPED DUE TO EARTH LEAKAGE INDIATOR SENSOR TEST TRIP MEHANISM POLE IDENTIFIATION SHEME.90 [.7] (N) POLE (L) POLE (L) POLE (L) ON I.500 [8.0].500 [.0] O BOX TYPE WIRE ONNETORS WITH PRESSURE PLATE All dimensions are in inches [millimeters]. Tolerance ±.05 [.8] unless otherwise specified. 0

107 PD-Series Form & Fit Drawings.500 [6.50].60 [57.0].50 [57.5] 6- [M] THREAD x.95 [.95] DEEP ( PLAES PER POLE).65 [6.7].650 [6.5].00 [06.68].00 [06.68] PDA & PDB ON I.500 [88.90].50 [57.5] [5.69].06 [5.7].000 [76.0].790 [0.0] TRIPPED DUE TO EARTH LEAKAGE INDIATOR.75 [9.5].750 [9.05] PD & PDD ON I.6 [6.6] PDE &PDP ON I TEST BUTTON.750 [95.5].50 [.8].550 [.96] PDF, PDG PDQ & PDR ON I.5 [0.86] OPTIONAL HANDLE GUARD.500 [.0].69 [6.8].50 [8.5] STANDARD 5mm SYMMETRIAL DIN RAIL (5 x 7.5 OR 5 x 5mm PER DIN EN500)..60 [57.0].06 [5.7].5 [8.58].50 [57.5].56 DIA [Ø.96] PLS. PANEL UT-OUT DETAIL ASSEMBLY SREW DRIVER REMOVAL All dimensions are in inches [millimeters]. Tolerance ±.00 [.5] unless otherwise specified. 05

108 -Series Remote Operated Module The arling Technologies Remote Operated ircuit Breaker (ROB) combines the convenience of remote ON, and Reset capability, with the safety and accuracy of a standard magnetic current sensing device, thus allowing operation of the breaker from various locations in a system, facility or site (while not sacrificing the ability to manually operate the breaker if required). With the ROB, service, diagnostics, load shedding and power distribution control functions can now be performed in areas that were previously unattended, inaccessible or unsafe. The ROB module allows remote operation of the -Series panel mount breaker, or the D-Series DIN rail mount breaker (up to poles) through hard wiring with a single pole, double throw switch connected to a standard power source, or more sophisticated relay and modem networks. The ROB module can be mounted to either side of the host breaker, while occupying only the width of a standard -Series pole. Several interface methods are available. Remote physical actuation of the host circuit breaker is achieved by connecting the ROB module s handle with the breakers. Being based on the -Series breaker, the ROB allows easy adaptation into existing panel designs. In addition, its' compact size allows efficient use of space for new design applications. With the ROB, arling has designed a versatile, compact and reliable solution -- in a hydraulic/magnetic circuit breaker or switch only device that can be operated both manually and remotely. Design Features include: ON- and trip indication Load shedding Energy management ompact size Automatic reset capable hoice of interface styles Panel or DIN rail mounting Manual Operation Override Fits into industry standard cut-out ROB Motor Specifications: Voltage input: VD to 80 VD Start current: < amp Switching time: < seconds ircuit Breaker Accessories To order a remote operated circuit breaker, add / plus the remote module part number to the end of the -Series circuit breaker catalog number. ex.abo60/rb0bu Match color & mounting inserts of breaker. / RB Series 0 B U Mounting Interface Lead Length 5 Voltage 6 Actuator olor 7 Mounting Insert 8 Agency Approval SERIES RB MOUNTING POSITION As viewed from back of breaker, line side up, pole left. 0 n/a - ordered separate from breaker Left Side Right Side INTERFAE Flying Leads Integral onnector Flying Leads w/ pin dual row connector (female) Flying Leads w/ pin dual row connector (male) 5 VOLTAGE RATING A VD B 0-0 VD 7 MOUNTING INSERT 6- x 0.95 ISO M x 5mm D -80 VD 0 VD E 0 VD 6 ATUATOR OLOR & LEGEND Actuator olor No legend I-O ON- Dual Legend olor White T A B Black Black U D White Red V F G White Yellow W M N 6 Black LEAD LENGTH 00 No Lead AGENY APPROVAL UL Recognized & SAertified E TUV ertified, UL Recognized & SAertified G UL 89 Listed & SAertified I UL 500 Ignition Protected,UL Recognized & SAertified Available with integral connector only. Integral and -pin dual row connectors not available with agency approval G: UL 89. TUV or VDE certified units must have I-O or dual legends. UL89 listed units must have ON- or dual legends. 06

109 Panel Hole Plug ircuit Breaker Accessories Threaded insert A & B-Series hole plugs are available in gloss finish. Snap-In A & B-Series hole plugs are available in matte finish. 8 M Accessory ode Series Poles Accessory Type 5 Actuator Type 6 olor 7 Finish AESSORY ODE 8 SERIES A A & B-Series & D-Series M M-Series POLES pole A, B, & D-Series Front Panel Snap-In Only Multi-pole inner Multi-pole outer AESSORY TYPE Panel Hole Plug 5 ATUATOR TYPE & MOUNTING STYLE Actuator Type Mounting Style M-Series Rocker Front Panel Snap-In A & B-Series Rocker 6- Threaded Insert A & B-Series Rocker ISO M Threaded Insert 6 & D-Series Handle 6- Threaded Insert 7 & D-Series Handle ISO M Threaded Insert 8 A, B, & D-Series Handle Front Panel Snap-In 6 OLOR Black White (M-Series only) 7 Gray (M-Series only) 7 FINISH Matte Gloss ( A & B-Series only) A & B-Series PB Socket The PB socket is available with the A-Series Handle, D up to 0 amps; A-Series Rocker, A/D up to 0 amps, and B-Series handle, A/D up to 0 amps. 8 A B Accessory ode Series Poles Interface 5 Terminal 6 olor AESSORY ODE 8 SERIES A A & B-Series POLES pole INTERFAE WITH AUXILIARY SWITH Yes No 5 AUXILIARY SWITH TERMINAL TYPE TAB, 0.0 Inches (Symmetrical terminal spacings) none 6 OLOR B Black -Series with Push-In Stud Terminals Removal Tool ircuit Breaker Removal Tool 8-X Part Number PART NUMBER 8-X X Removal Tool for 6- inserts Removal Tool for M inserts 07

110 ircuit Breaker Accessories & E-Series Power Selector The number of lockout sliding handles provided is one less than the number of sections specified, allowing one section to be live at a time. 8 E 6 B Accessory ode Series Poles Accessory Type 5 Sections 6 olor 7 Style AESSORY ODE 8 SERIES & D-Series E E-Series POLES poles 6 6 poles 9 9 poles AESSORY TYPE B Power Lockout Kit 5 SETIONS & POLES PER SETION Number of Sections Poles Per Section B Two Two Two Three F Three Two G Three Three 6 OLOR Black Red 7 STYLE arling Logo Textured Surface Glossy Surface 08

Products :: Circuit Protection :: Hydraulic/Magnetic Circuit Breakers

Products :: Circuit Protection :: Hydraulic/Magnetic Circuit Breakers Products :: Circuit Protection :: Hydraulic/Magnetic Circuit Breakers Miniature Hydraulic/Magnetic Circuit Breaker M-Series M-Series PDF elibrary The M-Series miniature hydraulic/magnetic circuit breakers

More information

Products :: Circuit Protection :: Hydraulic/Magnetic Circuit Breakers

Products :: Circuit Protection :: Hydraulic/Magnetic Circuit Breakers Products :: Circuit Protection :: Hydraulic/Magnetic Circuit Breakers Hydraulic/Magnetic Circuit Breaker B-Series B-Series PDF elibrary The B-Series hydraulic/magnetic circuit breakers are compact and

More information

PERCENT OF RATED CURRENT

PERCENT OF RATED CURRENT A-D Series Time Delay Values PERCENT OF RATED CURRENT NOTES: UL489 C-Series Breakers available with Delay Curves 11, 12, 14, 16, 21, 22, 24, 26, 42, 44, 46. Delay Curves 11,12,14,16,21,22,24,26,42,44,46,52,54,56:

More information

PERCENT OF RATED CURRENT

PERCENT OF RATED CURRENT A-D Series Time Delay Values PERENT OF RATED URRENT NOTES: UL489 -Series Breakers available with Delay urves 11, 12, 14, 16, 21, 22, 24, 26, 42, 44, 46. Delay urves 11,12,14,16,21,22,24,26,42,44,46,52,54,56:

More information

Time Delay Values (A, B, C & D-Series) AC 10000

Time Delay Values (A, B, C & D-Series) AC 10000 Time Delay Values (A, B, & D-Series) A 0 Instantaneous INSTANTANEOUS URVE. 20 0 D D.. INSTANTANEOUS URVE. 0 TRIP TIME IN SEONDS 0. TRIP TIME IN SEONDS 0..0.0 Ultrashort.00 0 200 300 400 500 600 700 800

More information

C-Series. Circuit Breaker

C-Series. Circuit Breaker C-Series Circuit Breaker The C-Series hydraulic/magnetic circuit breakers are ideal for applications that require higher amperage and voltage handling capability in a smaller package. They are available

More information

D-Series. Circuit Breaker

D-Series. Circuit Breaker D-Series Circuit Breaker Designed for snap-on-back panel rail mounting on either a 35mm x 7.5mm, or a 35mm x 15mm Symmetrical Din Rail, allowing rapid and simple mounting and removal of the breaker. It

More information

C-Series. Circuit Breaker

C-Series. Circuit Breaker C-Series Circuit Breaker The C-Series hydraulic/magnetic circuit breakers are ideal for applications that require higher amperage and voltage handling capability in a smaller package. They are available

More information

E-Series General Specifications

E-Series General Specifications -Series General Specifications Ideally suited for higher amperage applications. Available with front and back mounting, screw terminals, stud terminals and heavy duty box wire connectors for solid wire

More information

Time Delay Values (E-Series)

Time Delay Values (E-Series) Time Delay Values (ESeries) AC Instantaneous 00 0 INSTANTANEOUS CURVE NO. 20 00 0 DC D.C. INSTANTANEOUS CURVE NO. 0 0. 0..0.0.00 200 300 400 500 700 800 900 0 200.00 200 300 400 500 700 800 900 0 200 Short

More information

APL/UPL, 205/295 Series Magnetic Circuit Protectors

APL/UPL, 205/295 Series Magnetic Circuit Protectors APL/UPL, 205/295 APL/UPL, 205/295 Series Magnetic Circuit Protectors Introduction 68 Single & Multi-Pole 69 Barriers 7 Configurations 72 Operating Characteristics 74 Delay Curves 75 Specifications 80 Decision

More information

D-Series CIRCUIT BREAKER

D-Series CIRCUIT BREAKER D-Series CIRCUIT BREAKER Designed for snap-on-back panel rail mounting on either a 35mm x 7.5mm, or a 35mm x 15mm Symmetrical Din Rail, allowing rapid and simple mounting and removal of the breaker. It

More information

Magnetic Circuit Protectors 153. Multi-Pole Circuit Protectors 154. APL/UPL, 205/295 Barriers 155. Configurations 156. Operating Characteristics 158

Magnetic Circuit Protectors 153. Multi-Pole Circuit Protectors 154. APL/UPL, 205/295 Barriers 155. Configurations 156. Operating Characteristics 158 Magnetic Circuit Protectors 53 Multi-Pole Circuit Protectors 54 APL/UPL, 205/295 Barriers 55 Configurations 56 Operating Characteristics 58 Delay Curves 59 Specifications 64 APL/UPL Decision Tables 70

More information

209/219/229 Multi-Pole Circuit Protectors 202 branch circuit applications such as EDP, air conditioners, panel boards

209/219/229 Multi-Pole Circuit Protectors 202 branch circuit applications such as EDP, air conditioners, panel boards The 29, E-Frame circuit breaker combines power switching with accurate, reliable circuit protection 29/29/229 Magnetic Circuit Protectors 99 in a compact single or multipole 249 Power Selector Breaker

More information

PC-Series Ground Fault Circuit Protection

PC-Series Ground Fault Circuit Protection PC-Series Ground Fault Circuit Protection The PC-Series, AC Residual Current Circuit Breaker with Overcurrent Protection (RCBO), combines the ground fault protection of a GFCI with the familiar overcurrent

More information

M-Series. Circuit Breaker

M-Series. Circuit Breaker M-Series Circuit Breaker The M-Series is a low cost, miniature hydraulic/magnetic circuit breakers ideally designed for demanding applications requiring space saving features, aesthetics and snap-in front

More information

IELR Rail-Mount Series Magnetic Circuit Protectors

IELR Rail-Mount Series Magnetic Circuit Protectors IELR Rail-Mount IELR Rail-Mount Series Magnetic Circuit Protectors Introduction 92 Single Pole 93 Specifications 94 Operating Characteristics 95 Delay Curves 96 Approvals & Decision Tables 200 IELR Series

More information

APG/UPG/IPG Series Existing Designs Only APG/UPG/IPG

APG/UPG/IPG Series Existing Designs Only APG/UPG/IPG APG/UPG/IPG Series Existing Designs Only APG/UPG/IPG APG/UPG/IPG Series Hydraulic Magnetic Circuit Protectors INTRODUCTION IMPORTANT NOTICE: The APG/UPG is a legacy product and no new design-in orders

More information

IELR Series

IELR Series IELR Series Rail-Mount Magnetic Circuit Protectors Introduction Poles Specifications Operating Characteristics Delay Curves Approvals Decision Tables 6 62 63 64 65 69 70 IELR Series Rail-Mount Hydraulic

More information

Circuit Protection. What is Circuit Protection?

Circuit Protection. What is Circuit Protection? Circuit Protection What is Circuit Protection? In an electrical circuit, we refer to an excess (FLA) flow of current as an overcurrent. Overcurrents, since they exceed design or rated values, are considered

More information

Ihr autorisierter Distributor: Neumüller Elektronik GmbH

Ihr autorisierter Distributor: Neumüller Elektronik GmbH IELR Series Rail-Mount Magnetic Circuit Protectors Introduction Poles Specifications Operating Characteristics Delay Curves Approvals Decision Tables 6 62 63 64 65 69 70 Neumüller Elektronik GmbH Gewerbegebiet

More information

MULTI 9 System Catalog UL Recognized C60N Supplementary Protectors

MULTI 9 System Catalog UL Recognized C60N Supplementary Protectors UL Recognized C60N Supplementary Protectors B Curve C60N Supplementary Protectors 1 MG24110 MG24125 MG24140 MG24155 15 MG17406 MG17436 MG17461 1.2 MG17402 MG17432 16 MG24118 MG24133 MG24148 MG24163 1.5

More information

Single Pole Circuit Breakers 83 Multi-Pole Circuit Breakers 84 APGHX/UPGHX Breakers 86 APGX/UPGX Breakers 87 APGN/UPGN Breakers 88 APG/UPG Handles

Single Pole Circuit Breakers 83 Multi-Pole Circuit Breakers 84 APGHX/UPGHX Breakers 86 APGX/UPGX Breakers 87 APGN/UPGN Breakers 88 APG/UPG Handles Single Pole Circuit Breakers 83 Multi-Pole Circuit Breakers 84 APGHX/UPGHX Breakers 86 APGX/UPGX Breakers 87 APGN/UPGN Breakers 88 APG/UPG Handles and Actuators 89 IPG Breakers 90 Configurations 9 Operating

More information

MULTI 9 System Catalog UL Recognized NC100H Supplementary Protectors

MULTI 9 System Catalog UL Recognized NC100H Supplementary Protectors B Curve NC100H Supplementary Protectors Rating 1P 2P 3P 4P 80 MG27164 MG27175 MG27186 MG27197 MULTI 9 System Catalog UL Recognized NC100H Supplementary Protectors C Curve NC100H Supplementary Protectors

More information

Selection Guide. Control Circuit and Load Protection. Allen-Bradley 1489-M2C020

Selection Guide. Control Circuit and Load Protection. Allen-Bradley 1489-M2C020 Selection Guide Control Circuit and Load Protection Circuit Protection Portfolio 1489-M Circuit Breakers Approved for branch circuit protection in the United States and Canada, and certified as Miniature

More information

E-Series General Specifications

E-Series General Specifications -Series General Specifications Ideally suited for higher amperage applications. Available with front and back mounting, screw terminals, stud terminals and heavy duty box wire connectors for solid wire

More information

24973 Circuit Breaker MINIATURE CIRCUIT BREAKER, 440VAC, 10A, CIRCUIT BREAKER TYPE: STANDARD

24973 Circuit Breaker MINIATURE CIRCUIT BREAKER, 440VAC, 10A, CIRCUIT BREAKER TYPE: STANDARD United States 24973 Circuit Breaker MINIATURE CIRCUIT BREAKER, 440VAC, 10A, CIRCUIT BREAKER TYPE: STANDARD Image not available Product Information Features and Specifications Approvals: IEC 60947-2 Rated

More information

209/219/229/249/279 SERIES HYDRAULIC MAGNETIC CIRCUIT PROTECTORS

209/219/229/249/279 SERIES HYDRAULIC MAGNETIC CIRCUIT PROTECTORS 209/219/229/249/279 SERIES HYDRAULIC MAGNETIC CIRCUIT PROTECTORS Introduction The 209, E-Frame circuit breaker combines power switching with accurate, reliable circuit protection in a compact single or

More information

CurrentWatch Current Sensors. EGF Series Ground Fault Sensors. Ground Fault Sensors with Solid-State or Mechanical Relay Outputs.

CurrentWatch Current Sensors. EGF Series Ground Fault Sensors. Ground Fault Sensors with Solid-State or Mechanical Relay Outputs. CurrentWatch Current Sensors Ground Fault Sensors with Solid-State or Mechanical Relay s 1 Contents Overview.................... 1 Model Selection, Switches...... 2 Model Selection, Accessories... 3 Wiring

More information

TeSys IEC Contactors and Overload Relays

TeSys IEC Contactors and Overload Relays TeSys IEC Contactors and Overload Relays Making High-Fault Short-Circuit Current Ratings Simple Schneider Electric is an industry leader in IEC contactors and overload relays, and is recognized as the

More information

Issued February DATA SHEET 5SX2 MCB. Based on Siemens Industrial Control Catalog

Issued February DATA SHEET 5SX2 MCB. Based on Siemens Industrial Control Catalog Issued February 2011 DATA SHEET 5SX2 MCB Based on Siemens Industrial Control Catalog General Data Trip characteristics Tripping characteristics acc. to EN 60 898 Tripping characteristic A, -5 Type A characteristic

More information

Magnetic and Hydraulic-Magnetic Circuit Breaker

Magnetic and Hydraulic-Magnetic Circuit Breaker Description Single or multipole hydraulic-magnetic circuit breakers with trip-free - mechanism and toggle actuation. A choice of switching characteristics ensures suitability for a wide range of applications.

More information

Introduction Circuit Protection

Introduction Circuit Protection Introduction Circuit Protection Weidmuller s DIN-rail mounted circuit breakers are available for use in applications where circuit protection must be able to distinguish between circuit overloads and short

More information

WHITE PAPER. Overload or Short Circuit Protection? How to protect your design against both dangers. E-T-A Circuit Breakers USA. E-T-A Circuit Breakers

WHITE PAPER. Overload or Short Circuit Protection? How to protect your design against both dangers. E-T-A Circuit Breakers USA. E-T-A Circuit Breakers Overload or Short Circuit Protection? How to protect your design against both dangers E-T-A Circuit Breakers USA E-T-A Circuit Breakers 1551 Bishop Court Mt. Prospect, IL 60056 (847) 827-7600 fax: (847)

More information

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-F...

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-F... Magnetic and Hydraulic-Magnetic Circuit Breaker 830-F... Description Single and multipole magnetic circuit breakers with trip-free mechanism and toggle actuation. A choice of fast magnetic only or hydraulically

More information

1492-SP Supplementary Protectors

1492-SP Supplementary Protectors Dual terminals provide wiring/bus bar flexibility and clamp from both sides to improve connection reliability Approval marks are easily visible on dome Terminal design helps prevent wiring misses Scratch-

More information

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-F...

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-F... Description Single and multipole magnetic circuit breakers with trip-free mechanism and toggle actuation. A choice of fast magnetic only or hydraulically delayed switching characteristics (S-type MO or

More information

Bulletin 1489 Circuit Breakers. Selection Guide

Bulletin 1489 Circuit Breakers. Selection Guide Bulletin 1489 s Selection Guide Overview/Description Bulletin 1489-A s Energy-limiting design protects downstream components better than conventional breakers during short circuits Field-mountable options

More information

PD-Series General Specifications

PD-Series General Specifications PD-Series General Specifications SmartGuard is an equipment ground fault protection device that combines hydraulic/magnetic circuit breaker and overload and short circuit protection and ground fault protection.

More information

Section 4 Ground-Fault Protection Devices

Section 4 Ground-Fault Protection Devices Multi 9 System Catalog Section 4Ground-Fault Protection Devices Section 4Ground-Fault Protection Devices Selection Table The Multi 9 System includes one UL Listed and three IEC rated product families that

More information

MG24434 Supplementary Protector SUPPLEMENTARY PROTECTOR, 240VAC, 16A, CIRCUIT BREAKER TYPE: STANDARD

MG24434 Supplementary Protector SUPPLEMENTARY PROTECTOR, 240VAC, 16A, CIRCUIT BREAKER TYPE: STANDARD United States MG24434 Supplementary Protector SUPPLEMENTARY PROTECTOR, 240VAC, 16A, CIRCUIT BREAKER TYPE: STANDARD Product Information Features and Specifications For Use With: OEM Panels Approvals: UL

More information

Machine Safety. Products

Machine Safety. Products January 23 Vol. 2, Ref. No. [1263] -1 Machine Safety Products Contents Description Page............................................. -2 Key Interlock Switches DIN Models.............................. -9

More information

60103 Circuit Breaker

60103 Circuit Breaker 6003 Circuit Breaker United States MINIATURE CIRCUIT BREAKER, 20/240VAC, 2A, CIRCUIT BREAKER TYPE: STANDARD Image not available Product Information Features and Specifications Circuit Breaker Type: Standard

More information

IELR Rail-Mount Series Magnetic Circuit Protectors

IELR Rail-Mount Series Magnetic Circuit Protectors Series Magnetic Circuit Protectors Introduction 53 Single Pole 54 Specifications 55 Operating Characteristics 56 Delay Curves 57 Approvals & Decision Tables 6 IELR Series Hydraulic Magnetic Circuit Protectors

More information

MINI-PS AC/10-15DC/8

MINI-PS AC/10-15DC/8 Primary-Switched Power Supply, Narrow Design Data Sheet 08/2004 MINI POWER provides: An extra narrow design, with widths of 22.5 mm, 45 mm, and 67.5 mm (0.886, 1.772, and 2.657 in.) Global use due to a

More information

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS SECTION 262816 - ENCLOSED SWITCHES AND CIRCUIT BREAKERS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division

More information

IAR/IUR/IER/CUR/CER Series 1RU Magnetic Circuit Protectors

IAR/IUR/IER/CUR/CER Series 1RU Magnetic Circuit Protectors IAR/IUR/IER/CUR/CER Series RU Magnetic Circuit Protectors IAR/IUR/IER/CUR/CER [RU] Introduction 49 Poles & Terminals 50 Configurations 53 Delay Curves & Specs 54 Operating Characteristics 55 Hardware 56

More information

FAZ Supplementary Protectors, FAZ Miniature Circuit Breakers, P2 Disconnect Switches Overview

FAZ Supplementary Protectors, FAZ Miniature Circuit Breakers, P2 Disconnect Switches Overview FAZ Supplementary Protectors, FAZ Miniature Circuit Breakers, P2 Disconnect Switches Overview Supplementary Protectors / Miniature Circuit Breakers Page System overview 10/003 10/001 Supplementary protectors

More information

Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protectors Specifications Bulletin Number 1492, 1692

Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protectors Specifications Bulletin Number 1492, 1692 Technical Data Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protectors Specifications Bulletin Number 1492, 1692 Topic Page 1489-M Miniature Circuit Breakers 1 1492-SP Supplementary Protectors

More information

5.1. Motor Protection and Monitoring. Contents. Product Overview. Monitoring Relays. D64R Series Digital Ground Fault Relays...

5.1. Motor Protection and Monitoring. Contents. Product Overview. Monitoring Relays. D64R Series Digital Ground Fault Relays... .1 Ground Fault Relays and Monitors Contents Description Current.................. Phase................... Voltage.................. Ground Fault Relays and Monitors D64R Series Digital Ground Fault Relays....

More information

PHOENIX CONTACT - 08/2009. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

PHOENIX CONTACT - 08/2009. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area. Primary-switched power supply for building automation INTERFACE Data sheet 103505_en_02 1 Description PHOENIX CONTACT - 08/2009 Features STEP POWER power supply units for building automation The new STEP

More information

Installation, Operation and Maintenance Manual

Installation, Operation and Maintenance Manual Document 481200 VGD-100 Vari-Green Drive Installation, Operation and Maintenance Manual Please read and save these instructions for future reference. Read carefully before attempting to assemble, install,

More information

CROWN LINE Power Bus Bar Distribution System

CROWN LINE Power Bus Bar Distribution System COWN LINE Power Bus Bar Distribution System COWN LINE Power Bus Bar Distribution System The pluggable bus bar system Currents up to 300 Amps Up to 2 meters in length Pluggable breakers VDE finger proof

More information

SECTION DISCONNECT SWITCHES

SECTION DISCONNECT SWITCHES SECTION 16440 DISCONNECT SWITCHES PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and other Division 01 Specification

More information

Voltage Current Front-mounting bracket

Voltage Current Front-mounting bracket Switching Power Supply S8PS Compact DIN-Rail Mounting Industrial Power Supplies with Capacities Up to 600 W Models range from 0 W to 600 W. Universal input: voltage range 0 to 240 VAC. Power Factor Correction

More information

STEP-PS/1AC/24DC/1.75

STEP-PS/1AC/24DC/1.75 Primary-switched power supply, 1 AC, output current 1.75 A INTERFACE Data Sheet 103506_en_00 1 Description PHOENIX CONTACT - 05/2008 Features STEP POWER power supply units for building automation The new

More information

PERFORMANCE SPECIFICATION SHEET

PERFORMANCE SPECIFICATION SHEET INCH-POUND MIL-PRF-39016/23F 15 June 2005 SUPERSEDING MIL-PRF-39016/23E 20 July 1988 PERFORMANCE SPECIFICATION SHEET RELAYS, ELECTROMAGNETIC, ESTABLISHED RELIABILITY, SPDT, LOW LEVEL TO 1.0 AMPERE WITH

More information

Model 720 Electromechanical Hour Meter

Model 720 Electromechanical Hour Meter Model 720 Electromechanical Hour Meter A 5 figure (reset) or 6 figure (non-reset), AC hour meter encased in a rugged steel housing and designed to mil-spec environmental requirements. The non-reset models

More information

UL 489 DIN rail branch circuit breakers

UL 489 DIN rail branch circuit breakers UL 9 DI rail branch circuit breakers FAZ-A circuit breakers Product Overview UL 9 DI rail branch circuit breakers FAZ-A circuit breakers PRODUCT OVERVIEW Optimum and efficient protection Optimum product

More information

CP30F Series Circuit Protector for Improving Safety and Wiring Workability

CP30F Series Circuit Protector for Improving Safety and Wiring Workability CP30F Series Circuit Protector for Improving Safety and Wiring Workability EMURA, Takeshi * A B S T R A C T A circuit protector is a circuit-breaker that possesses both overcurrent protection and switch

More information

Relays & Sockets. RQ Series. RQ Series PCB Relays Part Number Selection

Relays & Sockets. RQ Series. RQ Series PCB Relays Part Number Selection Q Series Q Series PB elays Switches & Pilot Lights Display Lights IDE Q relays are low-profile, PB relays that provide quality within a compact package. Size equals value. Q relays are small, yet maintain

More information

Ultra Slim Relays 24

Ultra Slim Relays 24 Ultra Slim Relays 24 Technical Data... 1 Specifications.2 Model Number Structure - Relays...3 Model Number Selection...4 Accessories...5 Safety Precautions...6 Ultra Slim Relays WERNER`s embody the latest

More information

MAINTENANCE MANUAL. EDACS REDUNDANT POWER SUPPLY SYSTEM 350A1441P1 and P2 POWER MODULE CHASSIS 350A1441P3, P4, AND P5 POWER MODULES TABLE OF CONTENTS

MAINTENANCE MANUAL. EDACS REDUNDANT POWER SUPPLY SYSTEM 350A1441P1 and P2 POWER MODULE CHASSIS 350A1441P3, P4, AND P5 POWER MODULES TABLE OF CONTENTS MAINTENANCE MANUAL EDACS REDUNDANT POWER SUPPLY SYSTEM 350A1441P1 and P2 POWER MODULE CHASSIS 350A1441P3, P4, AND P5 POWER MODULES TABLE OF CONTENTS SPECIFICATIONS*... 2 INTRODUCTION... 3 DESCRIPTION...

More information

OPERATING MANUAL FOR THE 30KV A.C. TEST SET P123. Bicotest High Voltage Products Ltd

OPERATING MANUAL FOR THE 30KV A.C. TEST SET P123. Bicotest High Voltage Products Ltd OPERATING MANUAL FOR THE 30KV A.C. TEST SET P123 Product: High Voltage AC Test Set Type: P123 Bicotest High Voltage Products Ltd Hellesdon Park Road, Drayton High Road, Norwich NR6 5DR United Kingdom Phone

More information

REDUNDANCY MODULE TSP-REM360 AND TSP-REM600

REDUNDANCY MODULE TSP-REM360 AND TSP-REM600 REDUNDANCY MODULE TSP-REM360 AND TSP-REM600 Operating Instructions Seite 1 Dimensions drawings: TSP-REM360 Weight: 0.882lb Gewicht: 0.40kg Seite 2 Dimensions drawings: TSP-REM600 Bottom view Top view Side

More information

PHOENIX CONTACT - 06/2007. DANGER OF EXPLOSION! Remove an item only when it is not connected to power or if it is located in the non-explosive area.

PHOENIX CONTACT - 06/2007. DANGER OF EXPLOSION! Remove an item only when it is not connected to power or if it is located in the non-explosive area. Primary switched power supply, 3-phase, output current: 40 A INTERFACE Data Sheet 102782_01_en PHOENIX CONTACT - 06/2007 Description TRIO POWER is the rail mountable 24 V power supply unit with basic functions.

More information

Applying branch circuit breakers and supplementary protectors in North America

Applying branch circuit breakers and supplementary protectors in North America Product Application AP01102005E WMZT WMZS Applying branch circuit breakers and supplementary protectors in North America Introduction Eaton offers two types of miniature circuit breakers for use in North

More information

Applying branch circuit breakers and supplementary protectors in North America

Applying branch circuit breakers and supplementary protectors in North America Supersedes June 2017 FAZ-NA-L FAZ-NA FAZ Applying branch circuit breakers and supplementary protectors in North America Introduction Eaton offers three types of miniature circuit breakers for use in North

More information

W69-X2Q12-20 Product Details

W69-X2Q12-20 Product Details TE Connectivity My Cart My Part Lists Sign In/Register English (Change) Have a Question? Chat with a Product Information Specialist What can we help you find? Products Industries Resources bout TE My ccount

More information

MDSP-Series 90kA, 150kA, 300kA Modular Distribution Surge Protector Type 2 Class II Surge Arrester

MDSP-Series 90kA, 150kA, 300kA Modular Distribution Surge Protector Type 2 Class II Surge Arrester These modular distribution panel protectors for three phase power systems are designed to prevent damage to electrical distribution systems from mainsborne transient voltages which can occur as the result

More information

PERFORMANCE SPECIFICATION SHEET

PERFORMANCE SPECIFICATION SHEET PERFORMANCE SPECIFICATION SHEET INCH-POUND w/amendment 1 22 September 2005 SUPERSEDING MIL-PRF-39016/19G 1 April 2005 RELAYS, ELECTROMAGNETIC, ESTABLISHED RELIABILITY, DPDT, LOW LEVEL TO 1 AMPERE WITH

More information

9926 Series Branch Rated Circuit Breakers AC Version

9926 Series Branch Rated Circuit Breakers AC Version Branch Rated AC Version Hydraulic Magnetic Single pole and double pole versions 20/240 VAC, 50/60 Hz Up to 25A Just 3 mm wide Mounts on 35mm DIN-rail UL 489 listed, CSA C22.2 No. 5-02, CE VDE Ordering

More information

1.3. Miniature Circuit Breakers and Supplementary Protectors. Contents. WMZS Circuit Breaker. UL 1077 DIN Rail Supplementary Protectors

1.3. Miniature Circuit Breakers and Supplementary Protectors. Contents. WMZS Circuit Breaker. UL 1077 DIN Rail Supplementary Protectors . Miniature Circuit Breakers and Supplementary Protectors UL 077 DIN Rail Supplementary Protectors WMZS Circuit Breakers Contents Description WMZS Circuit Breaker Standards and Certifications................

More information

SafeC S. Features. Typical Applications. Technical Data. Principle. Safety Relay

SafeC S. Features. Typical Applications. Technical Data. Principle. Safety Relay EN 954 SafeC S Safety Relay SafeC S: Narrow construction of only 22.5 mm SafeC S is a sturdy and extremely inexpensive safety relay which impresses with its unusual efficiency and versatility, despite

More information

RTU500 series Data Sheet Power Supply CP-E 24/2.5

RTU500 series Data Sheet Power Supply CP-E 24/2.5 Data Sheet Power Supply CP-E 24/2.5 Power Supply CP-E 24/2.5 Application The primary switch mode power supply offers two voltage input ranges. This enables the supply with AC or DC. Furthermore it is equipped

More information

Thermal-Magnetic Circuit Breaker 4220-T...

Thermal-Magnetic Circuit Breaker 4220-T... Thermal-Magnetic Circuit Breaker 40-T... Description Single, double and three pole thermal-magnetic circuit breakers with high rupture capacity to UL 489 (5 ka), EN/IEC 60934 (6kA) and UL 077 (5 ka). With

More information

COMPACT LED CONVERTERS 48 V

COMPACT LED CONVERTERS 48 V COMPACT LED CONVERTERS 48 V EasyLine 48 V 186691, 186692 Typical Applications Shop lighting for 48 V systems Furniture lighting EasyLine 48 V VERY COMPACT SHAPE VERY LOW RIPPLE CURRENT LONG SERVICE LIFETIME:

More information

OVERLOAD RELAYS POWER & ACTUATION PROVEN. series

OVERLOAD RELAYS POWER & ACTUATION PROVEN. series POWER & ACTUATION OVERLOAD RELAYS series Need reliable, accurate overload and phase-loss protection for your motors? c3controls Series Bimetallic Overload Relays provide unmatched protection and can be

More information

Cutler-Hammer. January 2001

Cutler-Hammer. January 2001 Cutler-Hammer January 0 Vol.,Ref. 2-2 Product Line Overview January 0 Vol., Ref. No. [068] 2 Product Line Description Cutler-Hammer Molded Case Circuit s are designed to provide circuit protection for

More information

APPLICATION CONTROL GUIDELINES. IntelliROL Power Supply PN Revision Date: March 15, 2017

APPLICATION CONTROL GUIDELINES. IntelliROL Power Supply PN Revision Date: March 15, 2017 APPLICATION CONTROL GUIDELINES IntelliROL Power Supply PN 1176718 Revision Date: March 15, 2017 Table of Contents List of Tables...3 TGW Safety Recommendation...4 Warnings and Safety Instructions...5 Introduction...6

More information

S8VE (60/90/120/180/240-W Models)

S8VE (60/90/120/180/240-W Models) Switch Mode Power Supply S8VE (60/90/120/180/240-W Models) CSM_S8VE_DS_E_1_1 60/90/120/180/240-W Models Improved Versions of Standard-type Power Supplies without Indication Monitor. Safety standards: UL508/60950-1,

More information

CompactBlock Guard I/O EtherNet/IP Safety Modules

CompactBlock Guard I/O EtherNet/IP Safety Modules Installation Instructions CompactBlock Guard I/O EtherNet/IP Safety Modules Catalog Numbers 1791ES-IB8XOBV4, 1791ES-IB16 Topic Page Important User Information 2 North American Hazardous Location Approval

More information

Solid-State Switching Devices

Solid-State Switching Devices Overview 3RF21 3RF20 3RF22 3RF23 SIRIUS 3RF2 solid-state switching devices Solid-state switching devices for resistive loads Solid-state relays Solid-state contactors Function modules Solid-state switching

More information

DX 3 MCB A / 16 ka 80 A to 125 A (1,5 module per pole)

DX 3 MCB A / 16 ka 80 A to 125 A (1,5 module per pole) 87045 LIMOGES Cedex Telephone: +33 5 55 06 87 87 FAX: +33 5 55 06 88 88 DX 3 MCB 10000 A / 16 ka CONTENTS PAGES 1. Description - Use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection...

More information

PERFORMANCE SPECIFICATION SHEET

PERFORMANCE SPECIFICATION SHEET INCH-POUND MIL-PRF-39016/41E 15 June 2005 SUPERSEDING MIL-PRF-39016/41D 20 July 1988 PERFORMANCE SPECIFICATION SHEET RELAYS, ELECTROMAGNETIC, ESTABLISHED RELIABILITY, DPDT, LOW LEVEL TO 1 AMPERE, TERMINALS

More information

Product Guide. UL 1077 DIN Rail Supplementary Protectors

Product Guide. UL 1077 DIN Rail Supplementary Protectors Product Guide UL 0 DIN Rail Supplementary Protectors UL 0 DIN Rail Supplementary Protectors Product Overview... Product Selection WMZS B Curve ( X I n Current Rating)..............................................

More information

KEPCO GIVES YOU ZERO-UP PROGRAMMABILITY IN AN AFFORDABLE POWER MODULE

KEPCO GIVES YOU ZERO-UP PROGRAMMABILITY IN AN AFFORDABLE POWER MODULE 146-1915 More than switch mode boxes with wide-range a-c/d-c input power factor correction and current-share capacity... KEPCO GIVES YOU ZERO-UP PROGRAMMABILITY IN AN AFFORDABLE POWER MODULE RKW 300W 92

More information

Learning Module 9: Miniature Circuit Breakers and Supplementary Protectors. 101 Basic Series

Learning Module 9: Miniature Circuit Breakers and Supplementary Protectors. 101 Basic Series Learning Module 9: Miniature Circuit Breakers and Supplementary Protectors 101 Basic Series What You Will Learn We ll step through each of these topics in detail: Introduction 4 Miniature Circuit Breakers

More information

OFFICE UPS MULTI-DEVICE PROTECTION UPS 500S/600S/750S

OFFICE UPS MULTI-DEVICE PROTECTION UPS 500S/600S/750S OFFICE UPS MULTI-DEVICE PROTECTION UPS 500S/600S/750S USER S MANUAL 1.Safety instructions Thank you for selecting this uninterrupted power source. It provides you with better protection for connected equipment.

More information

Understanding SCCR. THE BEST ELECTRICAL CONTROLS BUSINESS ON THE PLANET! Unmatched Service Superior Product Quality Advantage Pricing

Understanding SCCR. THE BEST ELECTRICAL CONTROLS BUSINESS ON THE PLANET! Unmatched Service Superior Product Quality Advantage Pricing Understanding SCCR What is SCCR? When it comes to industrial machinery, it s critical to ensure that electrical panels are designed and built with the proper SCCR to maintain the system, eliminate downtime

More information

CliQ II DC-UPS Module 24V 40A / DRU-24V40ABN

CliQ II DC-UPS Module 24V 40A / DRU-24V40ABN Highlights & Features Full corrosion resistant Aluminium chassis Suitable for 24V system up to 40A Built-in diagnostic monitoring for DC OK, Discharge and Battery Fail by relay contacts LED indicator for

More information

Bulletin 817 Thermistor Protection Relay

Bulletin 817 Thermistor Protection Relay 6 Bulletin 817 Accurate Temperature Monitoring for Critical Applications Automatic, Manual and Remote Reset Status Indicating LEDs DIN Rail or Panel Mounting Guarded Terminals IP20 1 N.O. and 1 N.C. Output

More information

low voltage GLOBAL CATALOGUE RANGE Motor Control Contactors - Thermal Overload Relay s - Manual Motor Starters

low voltage GLOBAL CATALOGUE RANGE Motor Control Contactors - Thermal Overload Relay s - Manual Motor Starters CTLOGUE GLOBL RNGE 2. Motor Control Contactors - Thermal Overload Relay s - Manual Motor Starters 2. 2. Product Overview. 2.2 Overload Relay Setting Range 2. - 2.8 Product Specifications 2.9-2. Contactor

More information

CROWN CLIP Series Sockets

CROWN CLIP Series Sockets OWN LIP Series Sockets Product Facts ompact design High performance OWN BND contacts urrents to 350 mps 1 Mates with solid or laminated blades Supports true hot-plug (current interruption)2 Float-mount

More information

ABL1RPM24100 regulated SMPS - single phase V input - 24 V output W

ABL1RPM24100 regulated SMPS - single phase V input - 24 V output W Characteristics regulated SMPS - single phase - 100..240 V input - 24 V output - 240 W Complementary Input voltage limits Network frequency limits Inrush current Main Range of product Product or component

More information

Power supply CP-E 48/1.25 Primary switch mode power supply

Power supply CP-E 48/1.25 Primary switch mode power supply Data sheet Power supply CP-E 48/1.25 Primary switch mode power supply The CP-E range offers enhanced functionality while the number of different types has been considerably reduced. Now all power supply

More information

MODEL: MAT3. [2] ALARM OUTPUT A: With Y: Without. Lightning Surge Protectors for Electronics Equipment M-RESTER

MODEL: MAT3. [2] ALARM OUTPUT A: With Y: Without. Lightning Surge Protectors for Electronics Equipment M-RESTER MODEL: MAT Lightning Surge Protectors for Electronics Equipment M-RESTER LIHTI SURE PROTETOR FOR THREE-PHASE POWER SUPPLY Functions & Features onnected in parallel between the power and earth lines regardless

More information

Bulletin 1492-MC 1492-MCGA, -MCEA 1492-SP

Bulletin 1492-MC 1492-MCGA, -MCEA 1492-SP Bulletin Control Circuit and Load Protection Product Overview Bulletin -MC -MCGA, -MCEA -SP Type Branch Ground Fault Detection Features /V, V & Y/V rating A interrupt / in. per pole wide... A @ UL Circuit

More information

29 $ Manual Motor Starters FREESHIPPING. MOTOR CONTROLS 25. Features: MMS-32H Frame. MMS-63H Frame.

29 $ Manual Motor Starters FREESHIPPING.  MOTOR CONTROLS 25. Features: MMS-32H Frame. MMS-63H Frame. www.factorymation.com/motorcontrols MOTOR CONTROLS 25 Manual Motor Starters High interrupt capacity Din rail and surface mounting Lockable handle (OFF position) IP20 finger safe terminals Class 10 thermal

More information

IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS

IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS IMPORTANT SAFETY INSTRUCTIONS IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS WARNING (SAVE THESE INSTRUCTIONS): This manual contains important instructions that should be followed during installation

More information