DOOR FRAME DOOR LEAF. Potential-free contact for external: Intercom Switch. - Home automation system. = 110V AC, 60Hz
|
|
- Adrian Goodman
- 6 years ago
- Views:
Transcription
1 SECURY Solid Automatic, brass handle, & 45mm Cable plate Duct, series DOOR FRAME DOOR LEAF Potential-free contact for external: - Intercom - Switch - Home automation system 03 5 Junction box SECURY Automatic Black = switch Grey = -0V Brown = +24V Cable duct Potential-free contact Intercom Switch Power supply = (not supplied) to, Cable duct = SECURY Automatic = XX-0-8 = K
2 GU-SECURY Solid brass Automatic handle with & 45mm plate Technical series Data Sheet Release: (potential-free contact) e.g. intercom or access control system +/~ /~ + Distribution box Cable duct 123 Black = control circuit Grey (blue) = minus Brown = plus Optional: use of cable disconnection plugs (included in delivery)
3 SECURY Solid Automatic, brass handle, & 45mm SECUREconnect plate series 200, Fingerprint Scanner or Code Keypad, DOOR FRAME DOOR LEAF Potential-free contact for external: - Intercom - Switch Optional or 03 5 Fingerprint scanner Code keypad Term.: V4 / 93 (short term open) SECURY Automatic Term.: V42(+) / G42(-) Black = 90 Grey = GS Brown = VS 94 = Brown 95 = Green 96 = White GS = Yellow Potential-free contact Intercom Switch Power supply = (not supplied) to, SECUREconnect 200 = B Faceplate for = SECUREconnect (2 required) Fingerprint scanner = B or Code keypad = B SECURY Automatic = XX-0-8 = K
4 , Solid brass SECUREconnect handle & 200, 45mm Fingerprint plate series Scanner or Code Keypad Connection Diagram Cable routing of module (leaf-side) Please use the enclosed system cable to connect the module. The SECUREconnect and the access control module communicate via an encoded bus. SECUREconnect 200F Connecting cable Grey (blue) Brown Black Signal GND (minus) 24 V (plus) Control line GS VS 90 Fingerprint scanner or code keypad Connecting cable Yellow White Green Brown Signal GND (minus) RS-485 A RS-485 B 24 V (plus) GS Connection terminals of SECUREconnect 200R (frame-side) The terminals V42 and G42 are provided for the connection of an external voltage supply to operate SECUREconnect 200. Attention: Only voltage sources in accordance with EN may be used. Stabilized power supply 110V AC /, Switch control (optional) SECUREconnect 200R
5 SECURY Solid Automatic, brass handle, & 45mm SECUREconnect plate series 200, DOOR FRAME DOOR LEAF Potential-free contact for external: - Intercom - Switch - Access control 03 5 Term.: V4 / 93 (short term open) Term.: V42(+) / G42(-) SECURY Automatic Black = 90 Grey = GS Brown = VS Potential-free contact Intercom Switch Access control Power supply = (not supplied) to, SECUREconnect 200 = B Faceplate for = SECUREconnect (2 required) SECURY Automatic = XX-0-8 = K
6 Assembly Door Multi-point Multipoint and Operating Locking Instructions System, Solid brass SECUREconnect handle & mm Connection plate series Diagram Connection diagram SECURY Automatic with (leaf-side) Impulse-controlled door opening time approx. 2s (cannot be adjusted). Permanent door opening time corresponds to duration of control signal. SECUREconnect 200F GS VS 90 Connection terminals of SECUREconnect 200R (frame-side) The terminals V42 and G42 are provided for the connection of an external voltage supply to operate SECUREconnect 200. Attention: Only voltage sources in accordance with EN may be used. Stabilized power supply 110V AC /, Switch control SECUREconnect 200R
7 Door Multi-point Locking System Assembly Door Multipoint Instructions Locking System How Solid to Reverse brass Latches handle & Connect 45mm plate Extension series to Door Lock REVERSE LATCH (Use flathead screwdriver) REVERSE AUTOMATIC LATCH (Use 4mm Allen T-key H ) Presse slightly while pulling the latch CONNECT AUTOMATIC EXTENSIONS TO DOOR LOCK (Use Torx 15 T-key H ) Cutting dimension 220mm 1. Loosen screw (do not remove) 2. Remove screw 470mm 3. Hook the driving rod to the coupling plate and retighten both screws How to Reverse Latches & Connect Extension to Door Lock_ V
Installing Keypad and Backplate
Installing Keypad and Backplate Fig.1 Positioning of Fixing Holes and Cable Outlet Cable Outlet, Drill Diameter 10mm for Cable Access Remove the back plate, which is fitted to rear of the keypad, using
More informationIMPORTANT AS YOU REMOVE THE CONNECTORS LABEL THE CONNECTOR WITH THE NAME OF PLUG WITH THE SHARPIE
TOOLS REQUIRED : small flat head screwdriver no wider than ⅛ or 3mm wide, phillips head screwdriver, 3mm allen wrench, self tapping screws #6 x ½, ¼ hex head driver, electric drill, wire cutters, fine
More informationRoto E-Tec. Electronic drive and control systems for windows and doors. Installation instructions for detachable miniature cable junctions
Roto E-Tec Electronic drive and control systems for windows and doors Installation instructions for detachable miniature cable junctions Liability exclusion All specifications in this brochure were diligently
More informationDigital Keypad Introduction
K2 Digital Keypad Introduction The K02 uses the latest microprocessor technology to operate door strikes and security systems that require a momentary (timed) or latching dry contact closure. All programming
More informationIncremental encoders Solid shaft with clamping or synchro flange pulses per revolution
GI55, GI56 Features Encoder with solid shaft ø mm or ø6 mm Max. 6000 pulses per revolution Optical sensing method Clamping or synchro flange Industrial standard High rotation speed up to 000 rpm Optional
More informationMLC 420. MAGNETIC Press Brake ENCODERS OPERATION MANUAL
MLC 420 MAGNETIC Press Brake ENCODERS NON-CONTACT INTEGRATED BEARING SYSTEM USER SELECTABLE REFERENCE POSITION LEFT OR RIGHT MOUNTING HIGH RESOLUTION FROM 0.005mm HIGH PROTECTİON AGAİNST VIBRATION IP67
More informationGV-EL124S Electric Strike
GV-EL124S Electric Strike Featured with a built-in door status sensor, the GV-EL124S is a fail-secure electric strike, but it is field convertible from fail secure to fail safe. It can be mounted either
More informationPowerFlex DC Drive Frame B Pulse Transformer Circuit Board
Installation Instructions PowerFlex DC Drive Frame B Pulse Transformer Circuit Board ATTENTION: Only qualified personnel familiar with DC drives and associated machinery should plan or implement the installation,
More informationSkullcandy Air Raid USB Board Replacement
Skullcandy Air Raid USB Board Replacement The USB port should be replaced if it is visibly broken or the device will no longer charge. Written By: Cyrene ifixit CC BY-NC-SA www.ifixit.com Page 1 of 12
More informationPowerFlex DC Drive - Frame A Switching Power Supply Circuit Board
Installation Instructions PowerFlex DC Drive - Frame A Switching Power Supply Circuit Board ATTENTION: Only qualified personnel familiar with DC drives and associated machinery should plan or implement
More informationCM-110SK Standalone Keypad Installation Instructions
CM-0SK Standalone Keypad Installation Instructions. Packing List Qty Name Remarks 2 2 Keypad User manual Screwdriver Wall plugs Self-tapping screws Torx screw 0.8 x 2.4 Φ(20 mm 60 mm) 0.24 x.2 Φ (6 mm
More informationilock control unit Wiring Manual website: phone: +(48)
ilock control unit Wiring Manual e-mail: contact@ilocksystems.com website: www.ilocksystems.com phone: +(48) 61 669 06 87 1 P a g e Table of contents 1. Basic information... 2 1.1. Scheme 01... 3 2. Fingerprint
More information(Catalog Numbers 1394-FK10TS and -FK22TS)
Installation Instructions 1394 Fan Kit (Catalog Numbers 1394-FK10TS and -FK22TS) This publication provides installation instructions for the Allen-Bradley 1394 fan kit. The fan kit applies to the following
More informationKeypad CT2000. Art. No.: , (black) Art. No.: , (white) Installation Manual
secure open Keypad CT Art. No.:, (black) Art. No.:, (white) Installation Manual CT_installation_ENGmay Conlan ApS Speditorvej A DK- Aalborg Tel: + Fax: + www.conlan.eu info@conlan.eu Table of contents.
More informationUltra short throw lens installation
Ultra short throw lens installation The ultra short throw lens 0.36 UST GS (P/N: 140-133108-XX) allows you to position your projector as close as possible to your screen or display. Unless otherwise indicated,
More informationMegatouch FORCE Monitor Chassis Board Replacement
Megatouch FORCE Monitor Chassis Board Replacement Visit the Merit Industries, Inc. Web site http://www.meritind.com merit industries, inc. PM0337-01 Rev C Table of Contents FORCE Classic Monitor Chassis
More informationConnecting a Cisco Reader Module
CHAPTER 3 Overview The optional Cisco Reader Module (Figure 3-1) is similar to the Cisco Physical Access Gateway, providing the same ports for Weigand readers and other input and output devices. The Cisco
More informationCV-110SPK Standalone Keypad/Prox Access Control Installation Instructions
CV-110SPK Standalone Keypad/Prox Access Control Installation Instructions 1. Packing List Qty Name Remarks 1 1 1 2 2 1 Keypad User manual Screwdriver Wall plugs Self-tapping screws Torx screw 0.8 x 2.4
More informationRemoval and Installation8
8 Screw Types 8-4 Top Cover Assembly 8-5 Left Hand Cover 8-6 Right Hand Cover 8-10 Front Panel Assembly 8-14 Left Rear Cover 8-15 Right Rear Cover 8-16 Extension Cover (60" Model only) 8-17 Media Lever
More information74 PS range Push-buttons, selectors and indicators Ø 22mm
74 PS range Push-buttons, selectors and indicators Ø 22mm Push-buttons, selectors, indicators and 22mm diameter pre-drilled technopolymer enclosures. Ideal for the creation of signalling and control units
More information1 IF-810 or IF-811 Terminal (Slave) 2 Intended Use. 3 Assembly and Installation _V IF-810/IF-811
95-10326_V2016-10-20 IF-810/IF-811 1 IF-810 or IF-811 Terminal (Slave) Thank you for choosing an Interflex system. With an IF-810 or IF-811 terminal (slave), you have purchased a reliable device for capturing
More informationR SERIES INSTALLATION GUIDE
R SERIES INSTALLATION GUIDE Welcome to your smartest install yet. Things you should know Latch R is a proximity reader, keypad, and wireless entry system, that can be operated as a standalone device or
More informationPowerBook G4 Aluminum 15" GHz Modem Replacement
PowerBook G4 Aluminum 15" 1-1.5 GHz Modem Replacement Written By: irobot ifixit CC BY-NC-SA www.ifixit.com Page 1 of 15 INTRODUCTION 56k internal modem, standard on all models. TOOLS: Coin (1) Phillips
More informationFront-door station series for surface-mounting Profi-Economic PES Profi-Design PDS
Product information Front-door station series for surface-mounting Profi-Economic PES Profi-Design PDS PI_GB_PES_PDS_Art0015689_1v0.doc 2 10/2005 In Table of contents Scope of delivery...3 Safety notices...3
More informationAbsolute encoders - bus interfaces Solid shaft with clamping or synchro flange Optical multiturn encoders 13 bit ST / 12 bit MT, RS485
Optical multiturn encoders 1 bit ST / 12 bit MT, RS485 Features Encoder multiturn / RS485 Optical sensing method Resolution: singleturn 1 bit, multiturn 12 bit Clamping or synchro flange Fieldbus protocol
More informationF6-Fingerprint. Access Control/Reader. User Manual. F6 - Simplified Instruction. (Master Code) # (Factory default:1234) Enter the Programming Mode
-Fingerprint Access Control/Reader Function Description Enter the Programming Mode - Simplified Instruction Operation (Factory default:1234) Change the Master Code Add Fingerprint User Add Card User Add
More informationSwitches 6/1. 6/4 Introduction. 6/5 5TE8 control switches. 6/7 5TE4 8 pushbuttons. 6/9 5TE8 On/Off switches. 6/11 5TE1 switch disconnectors
6/4 Introduction 6/5 5TE8 control switches 6/7 5TE4 8 pushbuttons 6/9 5TE8 On/Off switches 4 6/11 5TE1 switch disconnectors 6 6/1 Switch to manual? Wherever electrical systems need to be switched on or
More informationProduct and functional description
Product and functional description The RS 525/23 Universal Dimmer is a KNX device with one dimmer output. The device is installed in an AP 118 Control Module Box or an AP 641 Room Control Box. The bus
More informationThe following forms are included. Computer files are contained in the directory v:\aqg_ops\improve\field_information\mailaudt. 1point.
TI 201B Forms for Flow Audits by Site Operators The following forms are included. Computer files are contained in the directory v:\aqg_ops\improve\field_information\mailaudt date initials 1point.doc 10/20/95
More informationilock control unit Wiring Manual website: phone: +(48)
ilock control unit Wiring Manual e-mail: contact@ilocksystems.com website: www.ilocksystems.com phone: +(48) 61 669 06 87 1 P a g e Table of contents 1. Basic information... 2 1.1. Scheme 01... 3 2. Fingerprint
More informationlumentouch SPECIFICATION SHEET Client: Project name: Order #: Type: Qty: FEATURES AND BENEFITS PACKAGE CONTENT HOW TO ORDER LTO
Client: Project name: Order #: Type: Qty: FEATURES AND BENEFITS Flat wall mounted lighting controller Universal mounting plate compatible with any electrical backbox MINI-USB connection for software programming
More informationOverview of types. Technical data
echnical data sheet SH2A-MF.. Multifunctional linear actuators for adjusting air dampers and slide valves in ventilation and air-conditioning systems for building services installations For air control
More informationMobileView Junction Box
Installation Instructions MobileView Junction Box (Catalog Number 2727-MRJB2) English The MobileView Junction Box (2727-MRJB2) integrates the following terminals into the control system: MobileView Guard
More informationPowerFlex DC Drive - Frame A SCR Modules for Drives with a Power Traces Circuit Board
Installation Instructions PowerFlex DC Drive - Frame A SCR Modules for Drives with a Power Traces Circuit Board!!! ATTENTION: Only qualified personnel familiar with DC drives and associated machinery should
More informationWINSTA. Full Line Catalog 2008/2009
WINSTA Full Line Catalog 2008/2009 5 Contents FULL LINE CATALOG W4, Volume 1 Rail-Mounted Terminal Block Systems FULL LINE CATALOG W4 Rail-Mounted Terminal Blocks Volume 1 X-COM -SYSTEM Terminal Strips
More informationIncremental encoders Solid shaft with EURO flange B pulses per revolution
Solid shaft with EURO flange B 0 5000 pulses per revolution EIL580 - EURO flange B - OptoPulse Features Size ø58 mm Precise optical sensing Output signal level TTL or HTL EURO flange B Connection axial,
More informationE1135C PDU and Pod Upgrade Procedure
E4030-90010 Rev. B 12/2003 In this Document... Tools Needed, 2 Contents of the Upgrade Kits, 2 Installation Procedures, 4 Verifying the Power Option of the New PDU, 4 Removing the PDU from the Support
More informationSingle-Core PVC 6491X
Single-Core PVC X 0/0 V Application PVC insulated only cable for fixed wiring purposes. Used in trunking or conduit, or may be surface mounted when used for earthing. Specifications In accordance with
More informationUpgrading LVDS Cables Instruction Sheet
Upgrading LVDS Cables Instruction Sheet INTRODUCTION Use the following instructions to replace the LVDS cables in CP2000-M/MR projectors. The new cables are slightly longer in length and allow for better
More informationHC900 Remote Termination Panel (RTP) For Relay Outputs
HC00 Remote Termination Panel (RTP) For Relay Outputs Document Number: --- Effective: //0 Supersedes: //0 Summary The Remote Termination Panel (RTP) provides an easy way to connect the HC00 controller
More informationDIGITAL DISPLAY. for Industry Applications. Series WAY-SSI. Key-Features:
DIGITAL DISPLAY for Industry Applications Series WAY-SSI Key-Features: Content: Technical Data.2 Technical Drawing...2 Electrical Connection...3 Description...4 Order Code & Accessories...6 - WAY-SSI-S:
More informationAbsolute encoders - SSI
Features Encoder multiturn / SSI Optical sensing Resolution: singleturn 14 bit, multiturn 12 bit Compact design Cost-efficient mounting High reliability by self-diagnostics Counting direction input Available
More informationWelch Allyn Connex Vital Signs Monitor 6000 Power Supply Replacement
Welch Allyn Connex Vital Signs Monitor 6000 Power Supply Replacement Replace the power supply in a 6000 series Welch Allyn Connex Vital Signs Monitor. Written By: Sam Lionheart ifixit CC BY-NC-SA www.ifixit.com
More informationOlympus TG-820 ihs Lens Replacement
Olympus TG-820 ihs Lens Replacement This guide will provide step by step instructions on how to replace the lens in the Olympus TG-820 ihs camera. Written By: Leslie Cade ifixit CC BY-NC-SA www.ifixit.com
More informationRSL PSM-2 Power Supply Module Project: Modifying a FlatCap2
RSL PSM-2 Power Supply Module Project: Modifying a FlatCap2 Dear Do-It-Yourselfer, The stock FlatCap2 is less than a stellar performer. Used with a CD5 CD player, for example, it gives flabby bass control,
More informationInductive displacement measurement system model series IE25P with programmable analogue interface
Inductive displacement measurement system Document No.: IE 12781 BE Date: 05.01.16 Contactless, wear-free sensor system Analogue interface Measuring range programmable Measuring range up to 0 mm Stainless
More informationSales: Technical: Fax:
DATA SHEET Weatherproof Order code Manufacturer code Description 23-2650 PX0410/02S/5560 2 WAY FREE SOCKET MICRO BUCCANNEER 23-2652 PX0410/03S/5560 3 WAY FREE SOCKET MICRO BUCCANNEER (RC) 23-2654 PX0410/04S/4550
More informationoptical sensors through-beam, retro-reflective, dif. reflection sensors 3000 transmitter with test input robust metal housing
design 12 x 12 x 64mm 12 x 12 x 69mm 12 x 12 x 74mm operating distance retro-reflective sensor operating distance diffuse reflection sensor sensing range up to 6.0m up to 4.0m up to 1.2m metal housing
More informationLenovo IdeaTab A1000L Audio Jack
Lenovo IdeaTab A1000L Audio Jack Replacement If you are unable to or having difficulty hearing using headphones, chances are you need a new headphone jack. Written By: Lauren Pluim ifixit CC BY-NC-SA www.ifixit.com
More information1 IF-812 or IF-815 Terminal (Slave) 2 Intended Use. 3 Assembly and Installation _V IF-812/IF-815
95-10324_V2016-11-23 IF-812/IF-815 1 IF-812 or IF-815 Terminal (Slave) Thank you for choosing an Interflex system. With an IF-812 or IF-815 terminal (slave), you have purchased a reliable device for capturing
More informationOracle <Insert Picture Here>
Slide 1 Oracle Slide 2 WZT-6509 version B Sun Fire Nehalem and Westmere Rack-Mount Server Installation and Replacement Welcome to the installation and replacement
More informationPowerBook G4 Aluminum 15" GHz PC Card Cage Replacement
PowerBook G4 Aluminum 15" 1-1.5 GHz PC Card Cage Replacement Written By: irobot ifixit CC BY-NC-SA www.ifixit.com Page 1 of 19 INTRODUCTION You can again use PC card accessories by replacing a faulty PC
More informationMac mini Late 2014 Power Supply Replacement
Mac mini Late 2014 Power Supply Replacement Replace the power supply in a Late 2014 Mac mini. Written By: Sam Lionheart ifixit CC BY-NC-SA www.ifixit.com Page 1 of 19 INTRODUCTION Use this guide to replace
More informationControl Box Setup - PRSalpha
888-680-4466 ShopBotTools.com Control Box Setup - PRSalpha Copyright 2016 ShopBot Tools, Inc. page 1 Copyright 2016 ShopBot Tools, Inc. page 2 Parts List: Hooking Up a PRSalpha Gantry Tool Powering the
More informationSERIE 59. Rear clamp. Frontal clamp HIGH RESOLUTION HOLLOW SHAFT INCREMENTAL ENCODER FOR INDUSTRIAL APPLICATIONS
HIGH RESOLUTION HOLLOW SHAFT INCREMENTAL ENCODER FOR INDUSTRIAL APPLICATIONS Resolution up to 50.000 pulses per turn External diameter 58 mm Hollow shaft from Ø 10 to 14 mm Protection class IP67 according
More informationAPES-14 HD-6500 & HD-7000 Version Operator s Training Manual
APES-14 HD-6500 & HD-7000 Version Operator s Training Manual Issue A1 09/03 PDI Part # 900600 Performance Design Inc. 2350 East Braniff St. Boise Idaho 83716 This manual contains very important safety
More informationFuser. Figure Remove the fuser assembly (1 of 2) 184 Chapter 5 Removal and replacement ENWW
Fuser 1. Remove the following assemblies. Scanner assembly. For the HP LaserJet 3015, see Scanner assembly. For the LaserJet 3020 and 3030, see Scanner assembly. Left cover. See Printer side covers. Rear
More informationReference Guide METTLER TOLEDO WMH Weighing Platforms
Reference Guide METTLER TOLEDO Weighing Platforms Mettler-Toledo GmbH 2005 Doc.No. KA021, 42908713C Weighing Platforms Reference Guide Contents 1 Initial Setup... 4 1.1 Installation... 4 1.2 Electrical
More informationSony NEX-7 Screen Replacement
Sony NEX-7 Screen Replacement If your camera's screen is broken or non functioning, this guide will show you how you can replace the screen. Written By: Jay Miley ifixit CC BY-NC-SA www.ifixit.com Page
More informationHome Automation, Inc. Model 53A00-1. OmniTouch 5.7 Touchscreen with Video
Home Automation, Inc. Model 53A00-1 OmniTouch 5.7 Touchscreen with Video Installation Manual Document Number 53I00-1 Rev A June, 2007 FCC NOTICE This device complies with FCC Rules Part 15. Operation is
More informationElectronic Preset Counter with 2 Presets and Print interface. NE213 Prog Features
Electronic Preset Counter with 2 Presets and Print interface NE21 Prog. 09 Features Order designation Order no. Interface RS22 Models Connection Functions LED-preset counter with 2 presets Batch counter
More informationOperating Instructions (Translation) 3. Safety Information. 1. Description. 2. Explosion Protection. Supply module Type 17-21BB-170x
1. Description The supply module was developed specially for direct mounting in hazardous areas in Zone 1 and 21 and is ATEX-certified. The supply module is a permanently installed piece of electrical
More informationInstalling 6 Indexer: PRS Standard Tools
888-680-4466 ShopBotTools.com Installing 6 Indexer: PRS Standard Tools Copyright 2016 ShopBot Tools, Inc. page 1 Copyright 2016 ShopBot Tools, Inc. page 2 Table of Contents Overview...5 Installing the
More informationSolid State Remote Power Controller E
Description The E-T-A is a transistorised switching device providing both protection and signalisation. It is suitable for all applications where the capabilities of the existing PLC s are not sufficient
More informationPOSIROT. PRAS2EX Magnetic Angle Sensor. Magnetic Angle Sensors (Dust-Ex-proof) Datasheet
Magnetic Angle Sensors (Dust-Ex-proof) Magnetic Angle Sensor Datasheet Copyright ASM GmbH Am Bleichbach 18-24 85452 Moosinning Germany The information presented in this data sheet does not form part of
More informationIncremental Encoder with Hollow Shaft
Incremental Encoder Type RI 36-H n miniature industry encoder for high number of pulses n short mounting length n easy mounting procedure n Application e.g.: - Motors - Machine tools - Packaging Machines
More informationTopic: TB No.: Date: Aug/2017. Model UC4, UC10 & UC45 twin pump variants Regulated 24V Pump Power supply upgrade OVERVIEW
Topic: TB No.: 10041 Date: Aug/2017 Affected Machines: UC4/UC10 &45 variants Priority: Medium Created By: Gareth Fitzpatrick From Serial No.:
More informationPHOENIX CONTACT - 01/2008
Ex Basic Terminal Blocks for Intrinsically Safe Signals With Knife Disconnection and Test Connections INTERFACE Data Sheet 102957_00_en PHOENIX CONTACT - 01/2008 1 Description PI-EX-TB and PI-EX-TB/T Ex
More informationInstallation Guide AWRON Display F26DGA
Seite: 1 Installation Guide AWRON Display F26DGA BMW F26 BMW X4 Seite: 2 Table of Contents Table of Contents 2 Scope of delivery 3 Toolkit 4 Cabel system 5 Schematic 6 Installation Guide Dismantling interior
More informationContents. BMS icom Manual
Contents 1. Introduction... 2 2. Safety Overview... 2 3. Package Contents... 3 4. Required Tools... 4 5. Installation Instructions... 6 Step 1: Mount BMS Unit... 6 Step 2: Clamp Setup... 6 Step 3: Sensing
More informationConnector System for Fluorescent Lighting Fixtures. Connectors for In-Line Mounting of Fluorescent Lighting Fixtures. Fully Polarized Connectors
Connector System for Fluorescent Lighting Fixtures Connectors for In-Line Mounting of Fluorescent Lighting Fixtures Fully Polarized Connectors Luminaire Disconnect Connectors Pluggable Lighting Connectors
More informationXbox One Heat Sink Replacement
Xbox One Heat Sink Replacement Use this guide to replace the heat sink in your Xbox One. Written By: Andrew Optimus Goldberg ifixit CC BY-NC-SA www.ifixit.com Page 1 of 23 INTRODUCTION Need to upgrade
More informationINSTALLATION INSTRUCTIONS
2015 F-150 8 MyTouch factory display 360º Vision System (Kit # AVMS-3618) DUE TO THE COMPLEXITY OF THIS KIT PROFESSIONAL INSTALLATION IS REQUIRED CALIBRATION KIT IS REQUIRED FOR FINAL PROGRAMMING -Must
More informationGSV-1A4 M12/2 M12/2. Highlights
GSV-1A4 M12/2 M12/2 Highlights Input sensitivity: 2mV/V; 4mV/V, 2 mv/v, 1mV/V, 0.5mV/V configurable via jumpers Output signals ±10V AND 12mA+-8mA on 15 pin Sub-D Integrated half and quarter bridge completion
More informationProduct and functional description
Product and functional description The RS 520/23 shutter / blind actuator is a KNX device with one relay output. The device is installed in an AP 118 Control Module Box or an AP 641 Room Control Box. The
More informationProduct and Applications Description. Note. Example of Operation. Installation Instructions. Application Programs WARNING
Product and Applications Description Note If the application program is not loaded completely by the ETS, you had better interrupt the 24 V voltage supply of the I/O-module during the loading interval.
More informationibook G3 14" Top Shield Replacement
Written By: irobot ifixit CC BY-NC-SA www.ifixit.com Page 1 of 18 INTRODUCTION The metallic top shield protects the logic board from electromagnetic interference. TOOLS: Coin (1) Paper Clip (1) Phillips
More informationMaterial: Weight: Shaft Loads: Cable: Connector:
Absolute Encoder Type 2RMHF-SSI Absolute Encoder - Ø 24 mm Blind Hollow Shaft - Ø 3 mm to Ø 1/4 inch Singleturn or Multiturn SSI Interface Binary or Gray Code Preset of Zero Position Choice of Counting
More informationOPERATING INSTRUCTION
OPERATING INSTRUCTION AUTORANGING MULTIMETER MAX Ω F C 10A MAX every 15 min. COM V SAFETY INFORMATION The following safety information must be observed to insure maximum personal safety during the operation
More informationThermoelectric Cooler Controller TED1000
Thermoelectric Cooler Controller TED1000 Operating Instructions MANUAL-TED1000-1.0 Aug 2015 Rev.1 2 Contents 1 General... 4 1.1 Warranty and Assistance... 4 1.2 Maintenance... 4 1.3 General Safety Considerations...
More informationUseful Notes: Guide to Railway Telephones
Useful Notes: Guide to Railway Telephones Copyright F. M. Spowart These notes are uncontrolled and NOT Network Rail endorsed, they are for information and guidance ONLY, NOT for testing or commissioning
More informationAdapter Kit - Remote QSI Electronics Installation Instructions
Adapter Kit Remote QSI Electronics Installation Instructions These installation instructions cover the adapter kit installation of the QSI1, QSI2 and QSI3 versions of communications electronics. The instructions
More informationL Series Humidity/-temperature sensors for use in heating, ventilation and air conditioning Technical data Humidity
Galltec Mess- und Regeltechnik GmbH MELA Sensortechnik GmbH Boschstr. 4 Raasdorfer Str. 18 71145 Bondorf. Germany 07987 Mohlsdorf-Teichwolframsdorf. Germany Tel. +49 (0)7457-9453-0 Tel. +49(0)3661-62704-0
More informationTechnical data. Your advantages
Technical data Nominal torque: 10.000 Nm to 25.000 Nm, bidirectional Customer-specific calibration upon request Rotational speed: 8.000 rpm Accuracy: ±0,5 % Temperature range: -30 C to +85 C Protection
More informationNOVOTURN Multiturn-Sensor non-contacting. Series RSM2800 digital SSI, SPI
NOVOTURN Multiturn-Sensor non-contacting Series RSM2800 digital SSI, SPI Special features True Power On System: counts turns even when not powered. Patented non-volatile technology does not require gears
More informationSupplementary instructions. Plug connector Harting HAN 7D. For point level sensors. Document ID: 34456
Supplementary instructions Plug connector Harting HAN 7D For point level sensors Document ID: 446 Contents Contents For your safety.... Appropriate use.... General safety instructions.... Safety instructions
More informationInstallation Guide for Mazak Mazatrol M - Plus, M-2, M32, T-Plus, T2
1 Installation Guide for Mazak Mazatrol M - Plus, M-2, M32, T-Plus, T2 Tsubis Part Number: LCD12-0046 Power Down 1. Power down the controller. 2. Power down the complete machine by turning off the rear
More informationModel No. ET-JPF200BE
Operating Instructions Floor Stand Kit Commercial Use Model No. ET-JPF200BE ET-JPF200WE ENGLISH FRANÇAIS ESPAÑOL DEUTSCH ITALIANO * The above illustration is of this product mounted to an optional projector.
More informationXbox 360 Motherboard Replacement
Xbox 360 Motherboard Replacement Motherboard replacement. Redigido por: Walter Galan ifixit CC BY-NC-SA pt.ifixit.com Página 1 de 29 INTRODUÇÃO Use this guide to completely strip down your motherboard.
More informationHinged safety switches, Palladio line
Hinged safety switches, Palladio line Selection diagram CONTACT BLOCKS 0C 0F 0M C F M snap action snap action snap action C F M CABLE AND CONNECTORS S A P KSM KAM Cable output Cable output M connector
More informationThe sensor fulfills the specifications of the EMC requirements, if the instructions in the manual are followed.
Assembly Instructions scancontrol 2600/2650/2900/2950 1. Warnings Connect the power supply and the display-/output device in accordance with the safety regulations for electrical equipment. The power supply
More informationSee «Overview of types» 90 s / 60 mm 150 s / 100 mm Manuelle Auslösung der Adaption durch Drücken der Taste «Adaption» oder mit dem PC-Tool
echnical data sheet LHA-MF..-P Multifunctional linear actuators for adjusting air dampers and slide valves in ventilation and air-conditioning systems for building services installations For air control
More informationIT 1910i. Industrial 2D-code hand-held scanner TECHNICAL DESCRIPTION. make technical changes EN /06. We reserve the right to
IT 1910i Industrial 2D-code hand-held scanner EN 50123791 2013/06 We reserve the right to make technical changes TECHNICAL DESCRIPTION 2013 Leuze electronic GmbH + Co. KG In der Braike 1 D-73277 Owen /
More informationADVANTAGE DKE QUICK START GUIDE. 2 Make sure you have everything shown here. 3. What s what? All important internal components labeled for you
1 of 6 START HERE 1 Carefully unpack box. 2 Make sure you have everything shown here. 3 Unlock and remove front panel of keypad unit, then using carriage bolts and hex nuts, attach unit to pedestal as
More informationPower distribution systems - accessories
Connections and terminals Line terminal X 221 3 01 Power-D-Box with sockets pre-wired Line terminal (max. 63 A) X 221 3 01 14.551 max. tightening torque 3.0 Nm 15.591 busbar X1, X2 blade terminals 6.3
More informationAC LEISURE PRO SHORE COMMANDER
AC LEISURE PRO SHORE COMMANDER ( BLACK CONTROL BOX ) Troubleshooting Guide Picture shown below is a vertical mount system INDEX 1.0 Power recommendations Licensed Electrician 1.1 Power recommendations
More informationPowerFlex 700L Liquid-to-Liquid Heat Exchanger Control Board Replacement
Installation Instructions PowerFlex 700L Liquid-to-Liquid Heat Exchanger Replacement ATTENTION: To avoid an electric shock hazard and prevent thermal damage, ensure that all power to the drive power module
More informationEPGG001. Fieldbus Gateway RS-232 to PROFINET. Industrial Communication. Technical Data. Part Number
Fieldbus Gateway RS-232 to PROFINET EPGG001 Part Number Easy handling Gateway from RS-232/422/485 interfaces to PROFINET With two Industrial Ethernet ports Technical Data Electrical Data Supply Voltage
More informationRCM-810. Technical specifications. Electro-Voice RCM-810. Enable powerful control and supervision capabilities
Electro-Voice RCM-0 RCM-0 Enable powerful control and supervision capabilities Integrate up to 00 devices in each remote control network, 50 with multiple networks Freely programmable control inputs and
More informationConnecting a Cisco Output Module
CHAPTER 5 Overview The optional Cisco Output Module (Figure 5-1) is attached to a Cisco Physical Access Gateway or Cisco Reader Module to provide additional connections for up to 8 outputs, each of which
More information