Ordering Information NT7E65DJ What s inside... SONET Transmission Products S/DMS TransportNode OC-3/OC-12 NE TBM
|
|
- Alvin Marsh
- 6 years ago
- Views:
Transcription
1 NT7E65DJ SONET Transmission Products S/DMS TransportNode OC-3/OC- NE TBM Ordering Information Standard Rel 4 February 00 What s inside... Configuration and ordering Bay frame and shelf hardware Circuit packs Optical, tributary, and peripheral cables Software Documentation Building blocks ordering Manufacturer discontinued items
2 Copyright Nortel Networks, All Rights Reserved The information contained herein is the property of Nortel Networks and is strictly confidential. Except as expressly authorized in writing by Nortel Networks, the holder shall keep all information contained herein confidential, shall disclose it only to its employees with a need to know, and shall protect it, in whole or in part, from disclosure and dissemination to third parties with the same degree of care it uses to protect its own confidential information, but with no less than reasonable care. Except as expressly authorized in writing by Nortel Networks, the holder is granted no rights to use the information contained herein. Nortel Networks and S/DMS TransportNode are trademarks of Nortel Networks. VT00 is a trademark of Digital Equipment Corporation. UNIX is a trademark of X/Open Company Ltd. Printed in Canada
3 iii Contents What s inside... About this document vii Configuration and ordering - System configurations - Site application - Transport and circuit capacity - OC-3 capacities -3 OC- capacities -4 Hardware options -6 Hardware baseline -7 Software options -7 Software loads -7 Software licences -7 Ordering -8 Bay frame and shelf hardware - TBM shelf and cooling COP kit (NT7E5AA) - Bay packages (framepacks) with the TBM shelf and cooling COP kit (NT7E5AA) - Ordering equipment separately -3 Bay frames -3 TBM shelves -4 Cooling units and accessories -5 Spare cooling modules -6 Other bay and shelf accessories -7 Individual circuit packs -0 Circuit packs 3- Transport Bandwidth Management 3- OC-3 interface circuit packs 3- OC- interface circuit packs 3-3 Ring loopback and overhead bridge circuit packs 3-5 OC- VTM optical interface circuit packs 3-6 Tributary circuit packs 3-7 BNC I/O circuit packs 3-7 DS3 STS mapper circuit pack 3-8 STS- interface circuit pack 3-8 DS VT mapper 3-9 Ordering Information Rel 4 Standard Feb 00
4 iv DS I/O circuit packs 3-0 Protection switcher circuit pack 3- Operations, administration, and maintenance circuit packs 3- Processor circuit pack 3- MIC circuit pack 3- Operations controller 3- External synchronization interface circuit packs 3-3 Miscellaneous circuit packs and components 3-5 Optical, tributary, and peripheral cables 4- Fiber single-mode optical cables 4- DS3 and STS- cables 4-3 STS- cables and accessories 4-4 Orderwire bridge and headset cables 4-7 ESI cables 4-7 CNet cables 4-8 Shelf alarm cables 4-9 User interface cables 4-0 Ethernet cables 4- DS cables 4- Miscellaneous cables 4-4 Test cords 4-7 Software 5- Software loads 5- Release 4 5- Release 3./3. 5- Release. 5- Release Release Release Release Release Release Release Release Software tool 5-4 OPC GUI 5-4 Software licences 5-5 Shelf configuration software 5-5 Optional OAM&P software 5-6 OPC application software 5-6 Port configuration software 5-6 Documentation 6- NTP packages 6- Quick reference guides 6-3 CD-ROM 6-4 S/DMS TransportNode OC-3/OC- NE TBM Vol Rel 4 Standard Feb 00
5 Change application procedures (CAPs), methods of procedure (MOPs), and user guide 6-5 Application letters and planning guides 6-5 Building blocks ordering 7- Manufacturer discontinued items 8- v Ordering Information Rel 4 Standard Feb 00
6 vi S/DMS TransportNode OC-3/OC- NE TBM Vol Rel 4 Standard Feb 00
7 About this document vii This document provides information on how to order an S/DMS TransportNode OC-3/OC- system and its components. Information includes guidelines for ordering bay frame and shelf hardware, circuit packs, cables, software, documentation, and replacements for manufacturer discontinued items. Tables in each chapter contain ordering information such as product engineering codes (PEC) and any other ordering codes needed. Audience This document is for the following members of the operating company: strategic planners current planners provisioners transmission standard engineers network administrators References in this document This document refers to the following documents: OC-3/OC- TBM System Description, Technical Specifications, Circuit Pack Descriptions, OC-48 Ordering Information, Ordering Information Rel 4 Standard Feb 00
8 viii S/DMS TransportNode OC-3/OC- NE TBM Vol Rel 4 Standard Feb 00
9 - Configuration and ordering - Use the following criteria to order an OC-3 or OC- system or network element: system configuration site application transport and tributary capacities options required System configurations OC-3 and OC- network elements are available in the following system configurations: point-to-point linear configuration with + protected network (NWK) transport interfaces linear configuration including terminals, regenerators, and add-drop multiplexers (ADM) with + protected NWK transport interfaces OC- NWK ring configuration (formerly referred to as an OC- ring with TA-30 protected transport optics) OC- NWK ring matched nodes configuration OC- VTM ring configuration OC- VTM ring matched nodes configuration Note: In an OC- NWK ring, the primary transport interface circuit packs in each ring ADM must be OC- networking interface circuit packs (NT7E0). In an OC- VTM ring, the primary transport interface circuit packs in each ring ADM must be OC- virtual tributary bandwidth management (VTM) optical interface circuit packs (NT7E05). For more information on the two ring types, see System Description, Tributary traffic can include a mix of the following: DS, DS3, and STS- circuits for OC-3 configurations DS, DS3, STS-, and OC-3 circuits for OC- configurations Ordering Information Rel 4 Standard Feb 00
10 - Configuration and ordering Each configuration is equipped for 30-nm single-mode optics operating at 55.5 Mbit/s (OC-3) or 6.08 Mbit/s (OC-). Systems operating at the OC- rate can also be equipped with 550-nm optics. For a VTM ring, only 30-nm optics are available. Site application The S/DMS TransportNode OC-3 and OC- network elements are available in standard bays for terminal, add-drop multiplexer (ADM), ring ADM, and regenerator applications. The OC-3/OC- Transport Bandwidth Manager (TBM) shelf can be equipped for the following applications: single-shelf OC-3 NWK terminal with mixed DS, DS3, and STS- tributaries single-shelf OC- NWK terminal with mixed DS, DS3, STS-, and OC-3 tributaries multishelf OC- NWK terminal supporting up to 336 DS tributaries single-shelf OC-3 NWK ADM with mixed DS, DS3, and STS- tributaries single-shelf OC- NWK ADM with mixed DS, DS3, STS-, and OC-3 tributaries single-shelf OC- NWK ring ADM with mixed DS, DS3, STS-, and OC-3 tributaries single-shelf OC- VTM ring ADM with mixed DS, DS3, STS-, and OC-3 tributaries single-shelf OC- NWK regenerator Transport and circuit capacity This section lists the maximum circuits for tributary combinations in each system configuration. Other service mixes below these maximums are permitted. For circuit pack locations to support these configurations, see Circuit Pack Descriptions, For ADM configurations, the tributary combinations listed terminate the most STS- signals possible. S/DMS TransportNode OC-3/OC- NE TBM Vol Rel 4 Standard Feb 00
11 Configuration and ordering -3 OC-3 capacities Terminal The OC-3 terminal shelf can operate with a maximum of 84 DS circuits (full DS complement, :6 protection) 56 DS circuits (:4 protection) and DS3 or STS- circuits (: protection) in a mixed configuration 8 DS circuits (: protection) and DS3 or STS- circuits (: protection) in a mixed configuration 3 DS3 or STS- circuits (full DS3/STS- complement, : protection) Add-drop multiplexer When an operations controller (OPC) is present, the OC-3 ADM shelf can operate with a maximum of DS circuits (:8 protection) 8 DS circuits (: protection) and 3 DS3 or STS- circuits (: protection) in a mixed configuration 6 DS3 or STS- circuits (full DS3/STS- complement, : or :3 protection) When an OPC is not present, the OC-3 ADM shelf can operate with a maximum of 68 DS circuits (full DS complement, : protection) 84 DS circuits (:6 protection) and 3 DS3 or STS- circuits (: protection) in a mixed configuration 56 DS circuits (:4 protection) and 4 DS3 or STS- circuits (: protection) in a mixed configuration 8 DS circuits (: protection) and 5 DS3 or STS- circuits (: protection) in a mixed configuration 6 DS3 or STS- circuits (full DS3/STS- complement, : protection) Ordering Information Rel 4 Standard Feb 00
12 -4 Configuration and ordering OC- capacities Terminal When only DS, DS3, and STS- tributaries are configured and an OPC is present, the OC- terminal shelf can operate with a maximum of 68 DS circuits (full DS complement, : protection) 84 DS circuits (:6 protection) and 3 DS3 or STS- circuits (: protection) in a mixed configuration 56 DS circuits (:4 protection) and 6 DS3 or STS- circuits (: protection) in a mixed configuration 8 DS circuits (: protection) and 9 DS3 or STS- circuits (:3 protection) in a mixed configuration DS3 or STS- circuits (full DS3/STS- complement, :4 protection) When OC-3 tributaries are configured and an OPC is present, the OC- terminal shelf can operate with a maximum of DS circuits (:8 protection) and OC-3 circuit (+ protected) in a mixed configuration 56 DS circuits (:4 protection) and OC-3 circuits (+ protected) in a mixed configuration 8 DS circuits (: protection) and 3 DS3 or STS- circuits (: protection) and OC-3 circuit (+ protected) in a mixed configuration 9 DS3 or STS- circuits (:3 protection) and OC-3 circuit (+ protected) in a mixed configuration 3 DS3 or STS- circuits (: protection) and OC-3 circuits (+ protected) in a mixed configuration 3 OC-3 circuits (+ protected) When OC-3 tributaries are configured and the OPC is absent, the OC- terminal shelf can operate with a maximum of 68 DS circuits (: protection) and OC-3 circuit (+ protected) in a mixed configuration DS circuits (:8 protection) and OC-3 circuit (+ protected) in a mixed configuration 56 DS circuits (:4 protection) and 3 OC-3 circuits (+ protected) in a mixed configuration 84 DS circuits (:6 protection) and 3 DS3 or STS- circuits (: protection) and OC-3 circuit (+ protected) in a mixed configuration S/DMS TransportNode OC-3/OC- NE TBM Vol Rel 4 Standard Feb 00
13 Configuration and ordering DS circuits (:4 protection) and 6 DS3 or STS- circuits (: protection) and OC-3 circuit (+ protected) in a mixed configuration 8 DS circuits (: protection) and 8 DS3 or STS- circuits (: protection) and OC-3 circuit (+ protected) in a mixed configuration 8 DS circuits (: protection) and 3 DS3 or STS- circuits (: protection) and OC-3 circuit (+ protected) in a mixed configuration 9 DS3 or STS- circuits (:3 protection) and OC-3 circuit (+ protected) in a mixed configuration 6 DS3 or STS- circuits (: protection) and OC-3 circuits (+ protected) in a mixed configuration 4 OC-3 circuits (+ protected) The + OC- multishelf terminal (consisting of a single-shelf terminal and a single-shelf linear ADM) can operate with a maximum of 336 DS circuits (full DS complement). Linear add-drop multiplexer When an OPC is present, the OC- linear ADM shelf can operate with a maximum of DS circuits (:8 protection) 8 DS circuits (: protection) and 3 DS3 or STS- circuits (: protection) in a mixed configuration 9 DS3 or STS- circuits (:3 protection) 54 DS circuits (:4 protection) and OC-3 circuit (+ protected) in a mixed configuration 3 DS3 or STS- circuits (: protection) and OC-3 circuit (+ protected) in a mixed configuration OC-3 circuits (+ protected) 3 OC-3 circuits (+ protected) When the OPC is absent, the OC- linear ADM shelf can operate with a maximum of 68 DS circuits (full DS complement, : protection) 84 DS circuits (:6 protection) and 3 DS3 or STS- circuits (: protection) in a mixed configuration 56 DS circuits (:4 protection) and 6 DS3 or STS- circuits (: protection) in a mixed configuration Ordering Information Rel 4 Standard Feb 00
14 -6 Configuration and ordering 8 DS circuits (: protection) and 9 DS3 or STS- circuits (:3 protection) in a mixed configuration DS3 or STS- circuits (:4 protection) DS circuits (:4 protection) and OC-3 circuit (+ protected) in a mixed configuration 54 DS circuits (:4 protection) and OC-3 circuit (+ protected) in a mixed configuration 8 DS circuits (: protection) and 3 DS3 or STS- circuits (: protection) and OC-3 circuit (+ protected) in a mixed configuration 6 DS3 or STS- circuits (: protection) and OC-3 circuit (+ protected) in a mixed configuration 3 OC-3 circuits (+ protected) OC- NWK ring add-drop multiplexer The OC- NWK ring ADM can operate with the same DS, DS3/STS-, and OC-3 capacity as the linear ADM. However, the linear ADM supports six more pass-through STS- signals in each configuration. OC- VTM ring add-drop multiplexer The OC- VTM ring ADM can operate with the same DS, DS3/STS-, and OC-3 capacity as the OC- terminal. Regenerator The OC- regenerator shelf regenerates the OC- optical signal and does not allow access to DS, DS3, or STS- channels. Control shelf Locate the OPC in the TBM control shelf when it cannot be placed in a TBM shelf that handles OC-3/OC- traffic. The control shelf is commonly used in ring systems and OC-3 tributaries. If you locate the OPC in a terminal, linear, or ring ADM shelf, you reduce the number of circuit pack locations available for tributary termination. Hardware options The following hardware options are available: frame and shelf hardware peripheral interface cables filler panels filler cards fiber-storage panel or fiber-splice tray breaker interface panel (BIP) modem S/DMS TransportNode OC-3/OC- NE TBM Vol Rel 4 Standard Feb 00
15 Configuration and ordering -7 external synchronization interface (ESI) required for ring configurations, or network elements that distribute timing Hardware baseline CAUTION Risk of traffic loss Using hardware with a release lower than the hardware baseline causes traffic outages. Check that all circuit packs meet the hardware baseline, before inserting them in the shelf. The hardware baseline is the minimum supported release of hardware for a software release. For information on hardware baselines, call the Nortel Networks Fax-on-Demand Service, Ensure you check all spare circuit packs at this time as well. Software options An S/DMS TransportNode includes one (primary) or two (primary and backup) operations controllers (OPC). The OPC manages the software that makes the hardware operational. Order the following software components separately: software loads software licences Software loads A TBM shelf includes a Right-to-copy certificate. This certificate permits you to load the most recent software version (as of the date of purchase) into the shelf. Software loads are provided on a digital data storage tape (DDS). An installation tape contains network element loads (software and firmware) and an OPC load. Software licences Software licences permit the use of software-based configurations and features. Four types of software require a licence: shelf configuration or application software optional operations, administration, maintenance, and provisioning (OAM&P) software OPC application software port configuration software Ordering Information Rel 4 Standard Feb 00
16 -8 Configuration and ordering Shelf configuration software Every shelf must have functionality software and the standard OAM&P software. Order shelf configuration software separately for each S/DMS TransportNode shelf. Shelf configuration software includes the following: functionality software (basic shelf functions) standard OAM&P software (minimum OAM&P software set) optional configuration software (enhanced functions) Optional OAM&P software Optional OAM&P software resides on both the OPC and network elements. Order all optional OAM&P features separately for each S/DMS TransportNode shelf. OPC application software Application software for the primary OPC is included in the standard OAM&P software package. The OPC application software enhances base capability with additional features such as a standby OPC and OPC-to-OPC file transfer. Order OPC application software separately for each OPC. Port configuration software Software to support user interface ports, serial telemetry (EA TBOS), and parallel telemetry is sold individually for each S/DMS TransportNode shelf. Contact your Nortel Networks sales representative for complete software ordering descriptions and codes. Ordering To order an S/DMS TransportNode system, identify the requirements for the following components: bay frame and shelf hardware circuit packs optical, tributary, and peripheral cabling software load and licenses documentation See the following chapters for information on how to order components. The last chapter includes information on manufacturer discontinued items and their replacements. S/DMS TransportNode OC-3/OC- NE TBM Vol Rel 4 Standard Feb 00
17 - Bay frame and shelf hardware - This chapter describes how to order OC-3 or OC- configuration packages, or individual bay and shelf components. Equipment is identified by product engineering code (PEC). TBM shelf and cooling COP kit (NT7E5AA) The OC- TBM shelf and cooling COP kit (NT7E5AA) replaces the TBM shelves and enhanced cooling required for VTM applications. The TBM shelf and cooling COP kit offers the following advantages: The shelf can be equipped with OC- (NT7E0xx) or OC- VTM (NT7E05xx) optical interface circuit packs allowing either TBM or VTM functionality. Each shelf is cooled as an independent unit. This integrated cooling eliminates the need for extra bay cooling (enhanced transport common equipment shelf NT4K9AC, through-flow cooling unit NT4K8BA and fan modules NT4K7BA) previously required for VTM applications. The shelf occupies 3 mounting spaces. A bay equipped with three TBM shelf and cooling COP kits (NT7E5AA) gains two mounting spaces for optional equipment such as fiber storage panels. The shelf incorporates four NT7E55AA fans, a cable organizer panel (COP), a plugin section, and an air filter drawer. The NT7E55AA fans can be used on OC- or OC-48 shelves. The housing for the fan assembly is plastic rather than sheet metal, making the fans easier to install. Note: OC-48 fans NT8E55AA cannot be used in the TBM shelf and cooling COP kit (NT7E5AA). Bay packages (framepacks) with the TBM shelf and cooling COP kit (NT7E5AA) Bay configuration packages include the following (see Table - for additional details): one, two or three TBM shelf and cooling COP kits (NT7E5AA) breaker interface panel (BIP) (NT7E56CA) Ordering Information Rel 4 Standard Feb 00
18 - Bay frame and shelf hardware shelf alarm cable (NT7E568) filler panels (NT7E5CA, 3/4-in and NT7E5AA, -in) for NT7E78GA/GB/GC/GD/GE only fiber storage panels NT7E58AB for NTFFCA/CB/CC/CD only regular anchor bolts a grounding strip a ground bar an ac outlet blank all necessary attachment screws cable ties Note: Earthquake anchor bolts are recommended for Zone 4. Order these bolts separately. Table - Bay frame and shelf configuration packages NT7E78 (Note ) NTFF0 series (Note ) NTFF series PEC GA GB GC GD GE AB BB CB DB CA CB CC CD NT7E70AA NT7E70BA NT7E70CA NT7E70DA NT7E56CA NT7E5AA NT7E568 NT7E58AB NT7E5AA NT7E5CA Note : For raised floor cabling, order the NT7E78GA or the NT7E78GB. For overhead cabling, order the NT7E78GD or the NT7E78GE. Note : For one TBM shelf in position, order the NTFF0AB. For one TBM shelf in position, order the NTFF0BB. S/DMS TransportNode OC-3/OC- NE TBM Vol Rel 4 Standard Feb 00
19 Bay frame and shelf hardware -3 Ordering equipment separately For individual components for an OC-3/OC- bay, order the following: one breaker interface panel (BIP) one, two or three TBM shelf and cooling COP kits (NT7E5AA), transport common equipment shelves (NT4K9AB), or enhanced transport common equipment shelves (NT4K9AC) enhanced through-flow cooling units if ordering the transport common equipment shelf (NT4K9AB) or the enhanced transport common equipment shelf (NT4K9AC) shelf alarm cables filler panels, fiber storage panel, fiber management tray or fiber splice trays, as required a spare fan module for each type of cooling unit one air filter if ordering the transport common equipment shelf (NT4K9AB) or the enhanced transport common equipment shelf (NT4K9AC) an ac outlet box for Underwriters Laboratories (UL) or Canadian Standards Association (CSA) applications, as required installation kit, as required frame junction kit or FiberWorld frame junction kit, as required frame extender, end guard or end guard extender, as required BIP modem, battery filter installation kit, or BIP panel filter kit, as required Note: The TBM shelf and cooling COP kit (NT7E5AA) replaces the transport common equipment shelf (NT4K9AB), the enhanced transport common equipment shelf (NT4K9AC), and the through-flow cooling unit (NT4K8BA). These items will be manufacturer discontinued in the future. See the following sections for a description of components. See Table - for ordering codes. Bay frames A bay frame which houses up to three network elements includes the following components: a bay frame regular anchor bolts a grounding strip a ground bar an ac outlet blank Ordering Information Rel 4 Standard Feb 00
20 -4 Bay frame and shelf hardware all necessary attachment screws Note: Earthquake anchor bolts are recommended for Zone 4. Order these bolts separately. Bay frames are 658 mm (6 in.) wide and 305 mm ( in.) deep. Front and rear access bay frames are available in six different heights:.3 m (7 ft).9 m (7.5 ft).44 m (8 ft).65 m (8.7 ft).74 m (9 ft) 3.5 m (.5 ft) TBM shelves One shelf is required for each OC- terminal, regenerator, ADM, or ring ADM each OC-3 terminal or ADM each TBM control shelf The TBM shelf and cooling COP kit (NT7E5AA) replaces the transport common equipment shelf (NT4K9AB) the enhanced common equipment shelf (NT4K9AC) the through-flow cooling unit (NT4K8BA). The transport common equipment shelf (NT4K9AB) and the through-flow cooling unit (NT4K8BA) are manufacturer discontinued. For more information on the TBM shelf and cooling COP kit (NT7E5AA), see the description on page -. Adding the TBM shelf and cooling COP kit (NT7E5AA) to existing bays The TBM shelf and cooling COP kit (NT7E5AA) can be added to TBM single-shelf and TBM two-shelf bay configurations. The NT7E5AA shelf cannot be integrated into existing three-shelf bay configurations. Only one additional NT7E5AA shelf can be installed in the NT7E78DA TBM configuration (single-shelf enhanced.3 m with raised floor cabling) because the through-flow cooling unit (NT4K8BA) takes up four mounting spaces. S/DMS TransportNode OC-3/OC- NE TBM Vol Rel 4 Standard Feb 00
21 Bay frame and shelf hardware -5 The NT7E5AA shelf can be installed only in position 3, in the NT7E78DD TBM configuration (single-shelf enhanced.3 m with overhead cabling). In position, the shelf obstructs the air flow of the cooling unit because of the louver air control design of the shelf. Remove filler panel NT7E5CA and move the colling unit, TBM shelf, and air filter up one mounting space to make room for the TBM shelf and cooling COP kit. Order one spare air filter (NPS ) and one spare fan module (NT7E55AA) for the TBM shelf and cooling COP kit (NT7E5AA). TBM power termination kit, cable adapter, and power cable assembly To add a TBM shelf and cooling COP kit (NT7E5AA) to a bay equipped with an NT7E56AA BIP, order one NT4K950 TBM power termination kit for each NT7E5AA kit (use the NT4K950 kit instead of the NT4K95 kit which comes with the TBM shelf and cooling COP kit). Order one TBM power cable assembly (NT7E5659) for each bay. The NT4K95 TBM power cable adapter is included with each transport common equipment shelf (NT4K9AB and NT4K9AA), to connect the shelf and the NT7E56BA or NT7E56CA BIP. To add a shelf to a bay equipped with an NT7E56AA BIP, order one NT4K950 TBM power termination kit to connect the shelf and the NT7E56AA BIP. Cooling units and accessories The TBM cooling unit kit (NT4KAB) and the TBM cooling unit kit with no air filter (NT4KBA) contain the following: one through-flow cooling unit (NT4K8BA) three fan modules for the through-flow cooling unit (NT4K7BA) one interface cable one filler LCAP miscellaneous hardware The TBM cooling unit kit (NT4KAB) also contains one air filter (NT4K5CA) to be mounted below the cooling unit or the lowest TBM shelf. Upgrading to VTM Order the TBM cooling unit kit (NT4KAB) and one CAP upgrade procedure NTR77CG for each site for one shelf equipped in the top position. Install the air filter below the NT4K8BA cooling shelf. Order the TBM cooling unit kit with no air filter (NT4KBA) and one CAP upgrade procedure NTR77CG for each site for the following configurations: one shelf equipped in the second position two-shelf configuration Ordering Information Rel 4 Standard Feb 00
22 -6 Bay frame and shelf hardware three-shelf configuration Note: For the three-shelf configuration, order also one COP cooling unit upgrade kit for each bay (NT4K9AS), one COP cooling unit installers kit (NT4K9AR) for each site, and one CAP upgrade procedure NTR770CG for each site. Spare cooling modules Order spare cooling modules as follows: NT4K7AA cooling module for the NT4K8AA cooling unit (one for each site) NT4K7BA through-flow cooling unit fan module for the NT4K8BA through-flow cooling unit (one for each site) one NT4K9AT COP cooling unit maintenance kit for each site for the NT4K9AC (three-shelf applications only) NT4K9AR cooling unit installation kit for the NT4K9AC (three-shelf applications) (kit contents are re-usable, and required for maintenance and installation) The through-flow cooling unit (NT4K8BA) and the through-flow cooling unit fan module (NT4K7BA) are not interchangeable with the cooling unit (NT4K8AA) and the cooling unit fan module (NT4K7AA). For the enhanced three-shelf configuration using the TBM shelf equipped with a COP cooling unit in position 3 (NT4K9AC), order one spare NT4K9AT COP cooling unit for each site. Note: For the TBM shelf and cooling COP kit (NT7E5AA), the cooling unit is integrated into the shelf and is not ordered separately. COP cooling unit maintenance kit The COP cooling unit maintenance kit includes a temporary thermal duct, a COP cooling unit without an LCAP, and two temporary ground bars. Order as required to replace defective COP cooling units. A COP cooling unit installation kit (NT4K9AR) is also required for maintenance. The items in this kit are re-usable. Cooling unit interface termination plug If more than one TBM shelf is installed in the bay, the cooling unit interface connector on the SIL remains unconnected. Terminate the connector with a cooling unit interface termination plug (NT4K85JB). Fan modules Order three fan modules for each cooling unit NT4K8AA or NT4K8BA. Order one spare fan module for each type of cooling unit (NT4K8AA or NT4K8BA) for each site. S/DMS TransportNode OC-3/OC- NE TBM Vol Rel 4 Standard Feb 00
23 Bay frame and shelf hardware -7 Order one spare fan module (NT7E55AA) for the TBM shelf and cooling COP kit (NT7E5AA) for each site. For the enhanced three-shelf configuration using the TBM shelf equipped with a COP cooling unit in position 3 (NT4K9AC), order one spare NT4K9AT COP cooling unit for each site. For the three-shelf configuration, ensure one re-usable NT4K9AR installation kit is available for the in-service upgrade of an NT4K9AB shelf to an NT4K9AC shelf. Ordering spares for VTM upgrades For one- and two-shelf configurations, order one spare fan module for the through-flow cooling unit (NT4K7BA) for each site. For three-shelf configurations, order one spare fan module for the through-flow cooling unit (NT4K7BA) for each site. Order one spare COP cooling unit maintenance kit (NT4K9AT) for each site. Air filters Order one air filter unit for each bay; the NT4K5CA is equipped directly below the cooling unit, or below the bottom TBM shelf (if equipped). For existing bays equipped with NT4KAA cooling unit kits which are not being replaced for VTM applications, order the NT4K5CA air filter with the first NT4K9AB shelf mounted below the cooling unit. For an enhanced bay, the air filter is included in the NT4KAB cooling unit kit. Order at least one spare air filter (NPS ) or six (NT7E6065)for the TBM shelf and cooling COP kit (NT7E5AA) for each site. Order at lease one spare air filter (NTS ) for each NT4K5AA or NT4K5CA air filter unit. Other bay and shelf accessories Breaker interface panels and battery filter installation kits Each bay requires one breaker interface panel (BIP). To upgrade the manufacturer discontinued BIP NT7E56AA to an NT7E56AB, order the breaker interface panel conversion kit (NT7E6035). The kit consists of the following: breaker interface display assembly (NT7E5604) a BIP identification label eight lamps For a BIP with an integral modem, order a battery filter installation kit (NT7E603) to complete the conversion. For a BIP with no integral modem, order the breaker interface panel filter kit (NT7E6060). Ordering Information Rel 4 Standard Feb 00
24 -8 Bay frame and shelf hardware BIP modem (400-baud) For the convenience of a built-in modem, order one 400-baud BIP modem for each BIP. Also, order the appropriate BIP modem cable (see Table 4-, Miscellaneous cables on page 4-6). BIP lamp Order 6-V lamps for the breaker interface panel NT7E56BA or NT7E56AB, or 8-V lamps for the NT7E56AA (manufacturer discontinued). BIP display assembly The breaker interface display assembly has the associated sub-miniature lamps mounted on the circuit board. Ac outlet box Order an ac outlet box for Underwriters Laboratories (UL) or Canadian Standards Association (CSA) applications as required. Circuit breaker and BIP fuse Order the kits as a spare or extra unit for field replacements. Fiber storage panel or fiber management storage tray Use fiber storage panels to store excess fiber for patchcords. As a general rule, if the bay has only one or two shelves, order one or two NT7E58AB fiber storage panels. If the bay has two or three shelves, order a fiber management storage tray. Order the NT7E58AC fiber management storage tray for bays with a high density of cable fibers (more than four fibers in a tray). The tray holds a maximum of 0 fibers, 0 of which can have miniature variable-optical attenuators (mvoa). As a general rule, order the fiber management storage tray if the bay has two or three shelves. Fiber splice tray Order one or two fiber splice trays for each bay. The fiber splice tray houses two organizer trays, each of which provides a splice location for up to fibers. Note: You cannot use the fiber splice tray to terminate outside plant fiber cable. Filler panel Order filler panels 44 mm (.75 in.) and 53 mm ( in.) as follows: Use the 44-mm filler panel (.75 in.) if no fiber storage panel is required. Use 53-mm filler panels ( in.) in positions,, and 3 when TBM shelves are not equipped (see Figure -). A maximum of three TBM shelves can be equipped for each bay (see Figure -). S/DMS TransportNode OC-3/OC- NE TBM Vol Rel 4 Standard Feb 00
25 Bay frame and shelf hardware -9 Figure - Filler panel 44 mm (.75 in.) 53 mm ( in.) BIP Fiber storage panel Position 53 mm ( in.) Position 53 mm ( in.) Position 3 Base Frame junction kit and FiberWorld frame junction kit Use the frame junction kit (NT7E73AA) to join two FiberWorld frames. Use the FiberWorld frame junction kit (NT7E73BA) to join a FiberWorld frame to a non-fiberworld frame. Order one kit for each frame according to customer requirement. Frame extender Use frame extenders to line up a frame with frames of higher heights [for example, to align a.3-m (7 ft) frame with a.74-m (9 ft) frame]. Order one frame extender for each frame according to customer requirement. Frame extenders are equipped with ground bridge loops. Frame end guard Order one or two frame end guards for each bay line-up (match bay height). Frame end guard extender Order one or two frame end guard extenders according to customer requirement. OC- consumable spares kit Order one kit for each bay. The spares kit contains eight lamps for an NT7E56AB BIP and one air filter. OC- terminal shelf cover and BIP panel front cover Order the kit as a replacement whenever the original unit has been damaged. Ordering Information Rel 4 Standard Feb 00
26 -0 Bay frame and shelf hardware TBM shelf installation kit Order one installation kit for each OC-3/OC- shelf. The installation kit contains the mounting bolts to install the Transport Bandwidth Manager (TBM) shelf onto the frame, and the DS3 cable supports to ensure that the minimum bending radius is not exceeded. Individual circuit packs Use circuit packs to add DS, DS3, STS-, or OC-3 channels to an existing transport channel at a terminal, ADM, or ring ADM site, subject to bandwidth and shelf layout limitations. Order individual circuit packs as field replaceable units or as optional equipment. See Circuit packs on page 3-. Table - Components for an OC-3/OC- network element Equipment description PEC Spare Bay frames Front access frame.3 m (7 ft) NT7E70AA no Front access frame.9 m (7.5 ft) NT7E70BA no Front access frame.44 m (8 ft) NT7E70CA yes Front access frame.74 m (9 ft) NT7E70DA yes Front access frame 3.50 m (.5 ft) NT7E70EA no Rear access frame.3 m (7 ft) NT7E70GA yes Rear access frame.9 m (7.5 ft) NT7E70HA yes Rear access frame 3.50 m (.5 ft) NT7E70LA no TBM shelves TBM shelf and cooling COP kit NT7E5AA no Transport common equipment shelf NT4K9AB no Enhanced transport common equipment shelf NT4K9AC no Cooling units and accessories Air filter (above NT4K8AA cooling unit) NT4K5AA yes Air filter (below NT4K8kAA cooling unit or lowest TBM shelf) NT4K5CA yes Air filter (non-woven, synthetic) for the NT4K9AB or NT4K9KAC TBM shelves Air filter (non-woven synthetic) for the TBM shelf and cooling COP kit (NT7E5AA) A03793 A yes yes Cooling unit cable adapter NT7E5654 no continued S/DMS TransportNode OC-3/OC- NE TBM Vol Rel 4 Standard Feb 00
27 Bay frame and shelf hardware - Table - (continued) Components for an OC-3/OC- network element Equipment description PEC Spare Cooling units and accessories (continued) Cooling unit kit NT4KAB no Cooling unit kit with no air filter NT4KBA no COP cooling unit maintenance kit NT4K9AT no COP cooling unit installation kit NT4K9AR no COP cooling unit upgrade kit NT4K9AS no Fan module for through-flow cooling unit NT4K8BA NT4K7BA no Fan module for the TBM shelf and the cooling COP kit (NT7E5AA) NT7E55AA no Through-flow cooling unit NT4K8BA no Other frame and shelf accessories Antistatic Wrist Strap A no Ac outlet box (CSA) NT7E76AA no Ac outlet box (UL) NT7E76BA no Breaker interface panel (BIP) NT7E56CA no Breaker interface panel conversion kit NT7E6035 no Breaker interface display assembly NT7E5604 yes Breaker interface panel (BIP) front cover for NT7E56AA/BA NT7E560 yes Breaker Interface Panel (BIP) front cover for NT7E56CA NT7E5675 yes Breaker Interface Panel (BIP) lamp LT03A7349, (6 V, for the NT7E56BA or NT7E56AB BIP) Breaker Interface Panel (BIP) lamp LT03A85, (8 V, for the NT7E56AA alarm lamps or NT7E56CA ACO lamp) A A yes yes Breaker Interface Panel (BIP) fuse NSQ4088L9, A for NT7E56CA A00899 yes Breaker Interface Panel (BIP) fuse NSQ4088L0, 3 A for NT7E56CA A yes Breaker Interface Panel (BIP) fuse NSQ4088L, 5 A for NT7E56CA A yes Breaker Interface Panel (BIP) fuse NSQ4088L4, 0 A for NT7E56CA A00976 yes Breaker Interface Panel (BIP) fuse NSQ4088L6,5 A for NT7E56CA A0665 yes Circuit breaker QBR605X05DZ, 5 A A yes Circuit breaker QBR60SX05D, 5 A for NT7E56CA BIP A03890 yes continued Ordering Information Rel 4 Standard Feb 00
28 - Bay frame and shelf hardware Table - (continued) Components for an OC-3/OC- network element Equipment description PEC Spare Other frame and shelf accessories (continued) Orderwire handset NTCA36AA no CNet termination plug NT7E507 yes Earthquake anchor bolts (Zone 4) NT7E74AA no End guard extender 0.6 m ( ft) NT7E75DA no End guard extender.37 m (4.5 ft) NT7E75EA no ESI Filler card NT7E39EA no FiberWorld frame junction kit NT7E73BA no Fiber storage panel NT7E58AB no Fiber management storage tray (0 fiber/0 mvoa) NT7E58AC no Fiber splice tray NT7E58FA no Filler panel 44 mm (.75 in.) NT7E5CA no Filler panel 78 mm (7 in.) NT7E5BA no Filler panel 53 mm ( in.) NT7E5AA no Frame extender 0.6 m ( ft) NT7E7DA no Frame extender.37 m (4.5 ft) NT7E7EA no Frame end guard.3 m (7 ft) NT7E7AA no Frame end guard.74 m (9 ft) NT7E7DA no Frame end guard 3.50 m (.5 ft) NT7E7EA no Frame junction kit NT7E73AA no Fiber storage panel cover NT7E580 yes FiberWorld blank DDS (4 mm) tape NT7E4TA no FiberWorld cleaning tape NT7E4TB no Frame insulation kit NT7E600 no OC- consumable spares kit NT7E600 yes OC- terminal shelf cover NT4K030 yes TBM shelf installation kit NT7E600 no end S/DMS TransportNode OC-3/OC- NE TBM Vol Rel 4 Standard Feb 00
29 3- Circuit packs 3- This chapter describes how to order circuit packs for an OC-3 or OC- network element. The equipment is identified by a product engineering code (PEC). Transport Bandwidth Management The number, type, and location of transport interface circuit packs depends on the TBM shelf application: A terminal shelf houses two bidirectional transport interface circuit packs in slots 9 and 0 (one working and one protection). A linear add-drop multiplexer (ADM) shelf houses four bidirectional transport interface circuit packs in slots 5, 7, 9, and 0 (two working and two protection). A network (NWK) ring ADM shelf houses two transport interface circuit packs (NT7E0) in slots 5 and 9, and two ring loopback circuit packs in slots 7 and 0. A VTM ring ADM shelf houses two transport interface circuit packs (NT7E05) in slots 9 and 0. A regenerator shelf houses two bidirectional transport interface circuit packs in slots 5 and 9. Each OC-3 and OC- shelf supports a wide range of DS, DS3, STS-, and OC-3 tributary configuration options. For more information, see System Description, See Table 3- to Table 3-6 for circuit pack ordering codes. Ordering Information Rel 4 Standard Feb 00
30 3- Circuit packs OC-3 interface circuit packs Each OC-3 networking interface is protected on a + basis (one working, one protection). OC-3 optical interface circuit packs are available in two reaches, each with a different system gain: Optical interface System gain (BER = 0 0 ) Intermediate reach (30 nm) Long reach (30 nm) db 8 db See Table 3- for ordering codes for OC-3 networking interface circuit packs. OC-3 interface circuit packs with changeable optical connectors OC-3 interface circuit packs with changeable optical connectors (NT7E0GA and NT7E0GB) provide the same functionality as OC-3 networking interface circuit packs with fixed optical connectors (NT7E0Cx and NT7E0Dx). OC-3 interface circuit packs NT7E0GA and NT7E0GB are compatible with Release 9 software, or later. Circuit packs with changeable optical connectors use a universal adapter to permit use of ferrule (FC), straight (ST) or subscriber connectors. (FC connectors are steel-threaded, SC connectors are plastic snap-in, and ST connectors are bayonet press-and-twist.) Connector types can be changed easily. Circuit packs with universal adapters reduce the number of spares needed and permit easier cleaning. Order circuit packs and optical connector kits separately. Optical connector kits Order an optical connector kit for each interface circuit pack: optical connector kit NTN459FC (FC connector) optical connector kit NTN459SC (SC connector) optical connector kit NTN459ST (ST connector) S/DMS TransportNode OC-3/OC- NE TBM Vol Rel 4 Standard Feb 00
31 Circuit packs 3-3 OC- interface circuit packs Each OC- interface is protected on a + basis (one working, one protection). OC- optical interface circuit packs are available in four reaches, each with a different system gain: Optical interface System gain (BER = 0 0) Intra-office (30 nm) Intermediate reach (30 nm) Long reach (30 nm) Extended reach (550 nm) 5 db 9 db 9 db 9. db OC- networking interface circuit packs (NT7E0xx) cannot perform virtual tributary bandwidth management (VTM). VTM capability is provided by the OC- VTM circuit pack (NT7E05xx). See Table 3- for ordering codes for OC- networking circuit packs. OC- interfaces with changeable optical connectors OC- interfaces with changeable optical connectors (NT7E0Px and NT7E0Nx) provide the same functionality as the OC- networking interfaces (linear, ring and intra-office) with fixed optical connectors (NT7E0Ex, NT7E0Fx, NT7E0Jx, NT7E0Kx, NT7E0Lx, NT7E0Mx and NT7E0XB). OC- interface circuit packs NT7E0Px and NT7E0Nx are compatible with Release 9 software, or later. Circuit packs with changeable optical connectors use a universal adapter to permit use of ferrule (FC), straight (ST) or subscriber connectors (SC). (FC connectors are steel-threaded, SC connectors are plastic snap-in, and ST connectors are bayonet press-and-twist.). Connector types can be changed easily. Circuit packs with universal adapters reduce the number of spares needed and permit easier cleaning. Order circuit packs and optical connector kits separately. The circuit packs with changeable optical connectors and their functional equivalents are as follows: NT7E0PA replaces NT7E33CA, NT7E33DA and NT7E33EA NT7E0PB replaces NT7E0FB, NT7E0FC, NT7E0FD, NT7E0LB, NT7E0LC, NT7E0LD and NT7E0XB NT7E0PC replaces NT7E0EB, NT7E0EC, NT7E0ED, NT7E0KB, NT7E0KC, and NT7E0KD NT7E0PD replaces NT7E0JB, NT7E0JC, NT7E0JD, NT7E0MB, NT7E0MC, and NT7E0MD Ordering Information Rel 4 Standard Feb 00
32 3-4 Circuit packs NT7E0NA replaces the NT7E33EA for Release, and later NT7E0NB replaces the NT7E0XB for Release, and later NT7E0GA replaces NT7E0DB, NT7E0DC and NT7E0DD NT7E0GB replaces NT7E0CB, NT7E0CC, and NT7E0CD Note : OC- circuit packs that provide ring functionality (NT7E0Ex, NT7E0Fx, NT7E0Jx, and NT7E0Px) can replace the OC- linear networking interface circuit packs (NT7E0Kx, NT7E0Lx, and NT7E0Mx) in all OC- linear applications. Note : Use OC- networking interfaces (NT7E0Px) for ADM functionality in a linear ADM, or in a NWK ring ADM (ring circuit packs only). Do not use NT7E0Px circuit packs in VTM ring ADM network elements. These network elements use NT7E05xx network interface circuit packs. Note 3: The OC- interface circuit packs (NT7E0Px) are compatible with Release 9, or later for SONET functionality. For Release 3, the NT7E0Px circuit packs can be programmed for SONET or SDH functionality. Note 4: Use circuit packs with SDH functionality only in terminal network elements. Note 5: The following interface circuit packs are manufacturer discontinued: NT7E0XB, NT7E33CA, NT7E33DA, and NT7E33EA. OC- intra-office and STS- circuit packs The OC- intra-office optical carrier circuit pack (NT7E0PA) provides the same functionality as the STS- electrical carrier circuit packs, for Release 9 software or later. The intra-office circuit pack uses fiber optic cables instead of the coaxial cables required for the STS- circuit pack. Connectors for the intra-office circuit pack are interchangeable and must be ordered separately. OC- SDH intra-office interface and OC- linear SDH IR interface circuit packs For Release 3 software or later, the OC- interface circuit packs (NT7E0Px) can be programmed for SONET or SDH functionality. For Release, the OC- SDH intra-office interface circuit pack (NT7E0NA) provides the same functionality as the STS- SONET/SDH interface circuit pack (NT7E33EA). The OC- linear SDH IR interface circuit pack (NT7E0NB) replaces the OC- IR 30 nm SONET/SDH interface circuit pack (NT7E0XB). Both the NT7E0NA and the NT7E0NB are compatible with Release 3. Use SDH circuit packs NT7E0NA and NT7E0NB for SONET/SDH midspan meets only. Although the midspan meet occurs at the OC-3 rate, the SS Bits within the H Byte that determine SDH or SONET functionality are controlled and provisioned by the OC- circuit packs. These circuit packs cannot be used in OC-48 tributary applications. S/DMS TransportNode OC-3/OC- NE TBM Vol Rel 4 Standard Feb 00
33 Circuit packs 3-5 Optical connector kits Order an optical connector kit with each circuit pack: optical connector kit NTN459FC (FC connectors) optical connector kit NTN495ST (ST connectors) optical connector kit NTN459SC (SC connectors) Ring loopback and overhead bridge circuit packs To provide protection in a NWK ring ADM, use two ring loopback circuit packs (NT7E35) in slots 7 and 0 and one overhead bridge circuit pack (NT7E36AA) in slot. For protection, all three circuit packs must be present in all NWK ring ADM network elements. VTM rings do not require ring loopback and overhead bridge circuit packs. Table 3- Networking interface circuit packs for OC-3 and OC- shelves Equipment PEC Spare OC-3 circuit packs OC-3 IR interface (30 nm) NT7E0GA yes OC-3 LR interface (30 nm) NT7E0GB yes OC- circuit packs OC- SDH intra-office interface NT7E0NA yes OC- linear SDH IR interface NT7E0NB yes OC- intra-office interface (30 nm) NT7E0PA yes OC- IR interface (30 nm) NT7E0PB yes OC- LR interface (30 nm) NT7E0PC yes OC- ELR interface (550 nm) NT7E0PD yes OC- ring loopback circuit pack (extended temp) NT7E35AA yes Overhead bridge circuit pack NT7E36AA yes Ordering Information Rel 4 Standard Feb 00
34 3-6 Circuit packs OC- VTM optical interface circuit packs The OC- VTM circuit pack can perform virtual tributary bandwidth management (VTM). VTM increases the efficiency of bandwidth use by providing the capability to assign, route, and control bandwidth in a SONET system with a granularity of VT.5 (.78 Mbit/s). Without VTM, VT.5 channels must be bulk-mapped in increments of 8. The VTM circuit pack is the primary optical interface in network elements with VTM. VTM capability is available only in OC- VTM ring configurations. The OC- VTM circuit pack cannot be used in linear configurations, nor can it be used in a ring that contains any NWK ring ADMs. (An NWK ring ADM has OC- networking interface circuit packs as the primary transport interfaces.) Order OC- VTM optical interface circuit packs with FC, ST or SC connectors. Circuit packs are available in two reaches, each with a different system gain: Optical interface System gain (BER = 0 0 ) (mid-span meet see note) Intermediate reach (30 nm) Long reach (30 nm).0 db 4.0 db Note:These worst-case parameters include allowances for connector losses, aging, equipment impairments due to implementation, and temperature degradation. These figures do not include the customer unallocated link margin. See Table 3- for ordering codes for VTM circuit packs. Note: OC- VTM optical interfaces are not direct replacements for OC- NWK units. Pay special attention to the optical link budget when ordering OC- VTM units for reconfigurations. For more information, see Technical Specifications, S/DMS TransportNode OC-3/OC- NE TBM Vol Rel 4 Standard Feb 00
35 Circuit packs 3-7 Table 3- OC- VTM optical interface circuit packs Equipment PEC Spare OC- IR 30 nm VTM optical interface circuit pack (connectorless) NT7E05JB yes OC- LR 30 VTM optical interface circuit pack (connectorless) NT7E05JC yes Tributary circuit packs Circuit packs are available to add DS, DS3, STS-, or OC-3 channels to an existing transport channel at a terminal, ADM, or ring ADM site, subject to bandwidth and shelf layout limitations. DS3 tributaries can be mixed with DS, STS-, and OC-3 tributaries on the same shelf. When mixing DS3 and STS- services, equip slots, 3, 5, and 7 with either DS3 mapper or STS- interface circuit packs (all combinations are supported). DS3 mappers and STS- interface circuit packs equipped in the same shelf share the protection switcher circuit pack (in slot ). Install OC-3 tributaries only in an OC- shelf. In an OC- mixed system, the DS VT mappers and DS3 STS mappers share the same slots. The quantity of DS VT mappers to be installed depends on the quantity of DS3 STS mappers being installed. In an OC-3 mixed system, install the DS3 STS mapper before the DS VT mappers. Once the DS3 STS mappers are installed, deprovision the unused DS3 ports before inserting a DS VT mapper. See Table 3-3 on page 3- for ordering codes. BNC I/O circuit packs Order three BNC I/O circuit packs (NT4K30AA) for each DS3 mapper or STS- interface circuit pack equipped. Each set of three BNC I/O circuit packs is associated with a DS3 STS mapper or STS- interface. Do not order any BNC I/O circuit packs for the protection DS3 STS mapper or protection STS- interface circuit pack. Order BNC I/O circuit packs in sets of three. The circuit packs fit into slots 38, 39, 40; 4, 43, 44; 46, 47, 48; and 50, 5, 5. In the OC- shelf, install up to BNC I/O circuit packs (the shelf can handle up to DS3 or STS- signals). In the OC-3 terminal shelf, install up to three BNC I/O circuit packs (the OC-3 signal can handle up to three DS3 or STS- signals). In the OC-3 add-drop multiplexer (ADM) shelf, install up to six BNC I/O circuit packs. (When no STS- signals are passed through, six is the limit because the ADM shelf can Ordering Information Rel 4 Standard Feb 00
36 3-8 Circuit packs handle up to three DS3 or STS- signals from each direction.) Install the circuit packs in sets of three in slots 38, 39, 40, and 4, 43, 44. For more information, see Circuit Pack Descriptions, DS3 STS mapper circuit pack Order one DS3 STS mapper for every three DS3 signals required. Order one STS- interface circuit pack for every three STS- signals required. Since a maximum of three DS3 or STS- tributaries in an OC-3 TBM terminal shelf, at most one working DS3 STS mapper or STS- interface circuit pack is required, excluding protection. Since you can provision a maximum of DS3s or STS-s in an OC- TBM shelf, at most four DS3 STS mapper or STS- interface circuit packs, or a combination totalling four, are required, excluding protection. Order one additional DS3 STS mapper for each shelf for protection of DS3 signals. This circuit pack is equipped in slot. Order one additional STS- interface circuit pack for each shelf for protection of STS- signals. This circuit pack is equipped in slot 3. Equip the working DS3 mappers and STS- interface circuit packs in any of slots, 3, 5, and 7 for the OC- shelf and in slots, 3, or 5 for the OC-3 shelf. Note: If the shelf contains at least one NT7E08BA mapper, then it is required that the protection mapper be an NT7E08BA mapper in order to prevent loss of enhanced functionality. STS- interface circuit pack Order one STS- interface circuit pack (NT7E09AA) for every three STS- signals required. Since you can provision a maximum of three DS3 or STS- signals in an OC-3 TBM terminal shelf, at most one working DS3 STS mapper or STS- interface circuit pack is required, excluding protection. Since you can provision a maximum of DS3 or STS- signals in an OC- TBM shelf, at most four DS3 STS mapper or STS- interface circuit packs (or a combination totalling four) are required, excluding protection. Order one additional DS3 STS mapper for each shelf for protection of DS3 signals. This circuit pack is equipped in slot. Order one additional STS- interface circuit pack for each shelf for protection of STS- signals. This circuit pack is equipped in slot 3. Equip the working DS3 mappers and STS- interface circuit packs in any of slots, 3, 5, and 7 for the OC- shelf and in slots, 3, or 5 for the OC-3 shelf. Equipping rules for the working STS- interface circuit packs are identical to the equipping rules for the working DS3 STS mappers. The STS- tributaries can be mixed with DS, DS3, and OC-3 tributaries on the same shelf. When mixing DS3 and STS- services, equip slots, 3, 5, and 7 with either DS3 S/DMS TransportNode OC-3/OC- NE TBM Vol Rel 4 Standard Feb 00
System Description NT7E65DJ What s inside... SONET Transmission Products S/DMS TransportNode OC-3/OC-12 NE TBM
NT7E65DJ 323-1111-100 SONET Transmission Products S/DMS TransportNode / NE TBM System Description Standard Rel 14 February 2001 What s inside... Introduction to S/DMS TransportNode TBM network element
More informationCircuit Pack Descriptions
NT7E65DJ 323-1111-102 SONET Transmission Products S/DMS TransportNode OC-3/OC-12 NE TBM Circuit Pack Descriptions Standard Rel 14 February 2001 What s inside... Circuit pack descriptions Copyright 1992
More informationSystem Applications Description
NT7E65DJ 323-1111-150 SONET Transmission Products S/DMS TransportNode / NE TBM System Applications Description Standard Rel 14 February 2001 What s inside... / network element applications Copyright 1992
More informationCS 1000 e-authorization Code Ordering Information Bulletin
Product Bulletin Date: 21 March 2011 CS 1000 e-authorization Code Ordering Information Bulletin Revision History Date Revision # Summary of Changes Original publication date Original publication. 1.0 Sept
More informationDigital Video Codec DV-45 DV-OC3 Unit Reference Manual
NT2H7908 323-1401-380 FiberWorld Transmission Product Digital Video Codec DV-45 DV- Unit Reference Manual FW02 3.01 Standard September 1995 FiberWorld Transmission Product Digital Video Codec DV-45 DV-
More informationMetropolis ADM MultiService Mux Compact Shelf
Metropolis ADM MultiService Mux Compact Shelf Engineering and Ordering Information Release 5.0 ED8C938-10 Issue 5 13-May-2005 AN55 Copyright 2005 Lucent Technologies All Rights Reserved A A About This
More informationCisco ONS CL Shelf Assembly Hardware
CHAPTER 1 This chapter provides a description of Cisco ONS 15310-CL shelf hardware. Instructions for installing equipment are provided in the Cisco ONS 15310-CL and Cisco ONS 15310-MA Procedure Guide.
More informationTraverse System Documentation. Installation and Commissioning Guide
Force10 Networks Inc. Traverse System Documentation Installation and Commissioning Guide Release TR3.2.2 Publication Date: April 2009 Document Number: 800-0002-TR322 Rev. A Copyright 2009 Force10 Networks,
More informationOPTera LH *A * Repeater Network Application Guide. What s inside... NTY311AX. Optical Networks Products
NTY311AX Optical Networks Products OPTera LH Repeater Network Application Guide Standard Rel 1.2 and 1.5 Issue 3 March 2000 What s inside... Introduction Network features OAM&P features Engineering rules
More informationCisco ONS MA Shelf Assembly Hardware
CHAPTER 2 Cisco ONS 15310-MA Shelf Assembly Hardware This chapter provides a description of Cisco ONS 15310-MA shelf hardware. Instructions for installing equipment are provided in the Cisco ONS 15310-CL
More informationPIX 535. PIX 535 Product Overview CHAPTER
CHAPTER 7 PIX 535 This chapter describes the installation of the PIX 535, and includes the following sections: PIX 535 Product Overview Installing a PIX 535 PIX 535 Feature Licenses Installing Failover
More informationCisco Prisma II Platform
Cisco Prisma II Platform In optical transmission systems, the network platform forms the foundation of the product family. The Cisco Prisma II platform provides network operators with the unique features
More informationNT7E65DJ
NT7E65DJ 323-1111-846 SONET Transmission Products S/DMS TransportNode OC-3/OC-12 NE TBM Common Procedures Standard Rel 14 February 2001 What s inside... Safety guidelines Replacing shelf covers Optical
More informationPrisma II Platform. Optoelectronics
Optoelectronics Prisma II Platform Description In optical transmission systems, the network platform forms the foundation of the product family. The Prisma II platform provides network operators with the
More informationHCS Newsletter No. 43, Dated Thursday, 04 December, 2003 HCS DataLine Cabinets and Enclosures
HCS - Made in Turkey With Pride! HCS Newsletter No. 43, Dated Thursday, 04 December, 2003 HCS DataLine Cabinets and Enclosures HCS, the only Turkish manufacturer of state-of-the-art LAN cabling systems
More informationInstallation Job Aid for Ethernet Routing Switch 5900 Series
Installation Job Aid for Ethernet Routing Switch 5900 Series Notices NN47211-301 Issue 05.01 November 2017 Notice paragraphs alert you about issues that require your attention. The following paragraphs
More informationQuick Start. This document describes how to install the Juniper Networks PTX5000 Packet Transport
PTX5000 Packet Transport Router Quick Start September 2017 Part Number: 530-066788 Revision 01 This document describes how to install the Juniper Networks PTX5000 Packet Transport Router. Contents Quick
More informationPIX 520. PIX 520 Product Overview CHAPTER
CHAPTER 5 PIX 520 This chapter guides you through the installation of the PIX 520, and includes the following sections: PIX 520 Product Overview, page 5-1 Installing the PIX 520, page 5-4 PIX 520 Feature
More informationOMEGA MODULAR PATCH PANEL EMPTY ENCLOSURE
OMEGA MODULAR PATCH PANEL EMPTY ENCLOSURE The Omega MPP enclosure is based on a 19" frame, with 4 empty module slots for MPP modules. Highly flexible : any mix between twisted pair and optical fiber modules.
More informationCisco CRS 3-Phase AC Power Distribution Unit Installation Guide 2. Cisco CRS 3-Phase AC Power Distribution Unit 2
Cisco CRS 3-Phase AC Power Distribution Unit Installation Guide Cisco CRS 3-Phase AC Power Distribution Unit Installation Guide 2 Cisco CRS 3-Phase AC Power Distribution Unit 2 Revised: November 18, 2016,
More informationArtisan Technology Group is your source for quality new and certified-used/pre-owned equipment
Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment FAST SHIPPING AND DELIVERY TENS OF THOUSANDS OF IN-STOCK ITEMS EQUIPMENT DEMOS HUNDREDS OF MANUFACTURERS SUPPORTED
More informationInstalling Power Modules
This chapter contains the procedures for installing cards and modules into the chassis after the chassis has been installed into a rack. This chapter also describes how to connect cables to RSP, RP, alarm,
More informationPIX 515/515E. PIX 515/515E Product Overview CHAPTER
CHAPTER 4 PIX 515/515E This chapter describes how to install the PIX 515/515E, and includes the following sections: PIX 515/515E Product Overview Installing a PIX 515/515E PIX 515/515E Feature Licenses
More informationSECTION 5 -- EQUIPMENT LAYOUT & EQUIPMENT ENVIRONMENTS
SECTION 5 -- EQUIPMENT LAYOUT & EQUIPMENT ENVIRONMENTS CONTENTS PAGE 1. GENERAL... 5-1 1.1. Introduction... 5-1 1.2. Equipment Layout Requirements... 5-1 2. EQUIPMENT FRAMES... 5-2 2.1. Introduction...
More informationInstalling the Cisco ADE 2130 and 2140 Series Appliance Hardware Options
CHAPTER 4 Installing the Cisco ADE 2130 and 2140 Series Appliance Hardware Options This chapter provides instructions for installing, replacing, and removing various hardware options in your Cisco ADE
More information2 Telecommunications Data Center Facility Requirements
Generic Requirements for Telecommunications Data Center Equipment and Spaces GR-3160-CORE Table of Contents Table of Contents Generic Requirements Notice of Disclaimer..................... iii Preface...........................................
More informationRS-232 Fiber Link Card System
USER GUIDE The leader in rugged fiber optic technology. U-152 2018B-0406 Fiber Link Card System SYSTEM INSTALLATION INFORMATION Introduction The Fiber Link Card system transports a full 9-Pin copper signal
More informationFiber Remote IPE Description, Installation, and Maintenance
Title page Nortel Networks Communication Server 1000 Nortel Networks Communication Server 1000 Release 4.0 Description, Installation, and Maintenance Document Number: 553-3021-354 Document Release: Standard
More informationReliability, Availability, and Serviceability (RAS)
CHAPTE 9 eliability, Availability, and erviceability (A) Overview The GX 8250 is designed for carrier-class reliability. ystem components can be configured for 100 percent redundancy, and all GX 8250 modules
More informationFCD-155. STM-1/OC-3 Terminal Multiplexer FEATURES
FEATURES SDH/SONET terminal multiplexer for grooming LAN and legacy traffic (TDM) over SDH/SONET networks Demarcation point between the carrier and the customer networks GFP (G.7041), LAPS (X.85/86) encapsulation
More informationChassis Overview. About the Cisco NCS 4016 Chassis. This chapter provides an overview of the Cisco NCS 4016 chassis and components.
This chapter provides an overview of the Cisco NCS 4016 chassis and components. About the Cisco NCS 4016 Chassis, page 1 Chassis Components, page 6 Chassis Cable Management, page 11 Safety Guidelines,
More informationTable of Contents. 1 Introduction. 2 Facility and Space Planning Requirements
1 Introduction 1.1 Purpose and Scope.................................. 1 1 1.2 Telecommunications Service Provider (TSP) Role................ 1 1 1.3 Equipment Manufacturer Role............................
More information9. NTP-C11 Remove and Replace an Ethernet Card, page 1-13 As needed, complete this procedure to remove and replace an ONS CL Ethernet card.
CHAPTER 1 This chapter provides procedures for installing the Cisco ONS 15310-CL shelf, cards, and fiber-optic cable. To view a summary of the tools and equipment required for installation, see the Required
More informationOAsys. SRS3000 1U Splice and Patch Shelf. Rack Mounted Products. Features and Benefits. Prysmian Part Number: See table on following pages.
SRS3000 1U Splice and Patch Shelf Prysmian Part Number: See table on following pages. The SRS3000 Splice and Patch Shelf is a modular unit available in a variety of configurations for integration in to
More informationor
Infinite possibilities for your data center The F-Series TeraFrame T M Cabinet System The F-Series TeraFrame Cabinet System from Chatsworth Products, Inc. (CPI) provides configurable thermal management
More informationNetwork Topologies & Error Performance Monitoring in SDH Technology
Network Topologies & Error Performance Monitoring in SDH Technology Shiva Sharma Electronics and Communications Department Dronacharya College of Engineering Gurgaon, Haryana Shiva.92@hotmail.com Abstract
More informationOptical Cards. 4.1 OC-N Cards OC-N Card Overview CHAPTER
CHAPTER 4 This chapter describes the Cisco ONS 15454 optical card features and functions. It includes descriptions, hardware specifications, and block diagrams for each optical card. For installation and
More informationInstallation Job Aid for Avaya Virtual Services Platform 8400
Installation Job Aid for Avaya Virtual Services Platform 8400 Support Release 4.2 NN47227-305 Issue 01.06 June 2015 Go to the Avaya Support website at http://support.avaya.com for the most up-to-date documentation,
More informationNetfinity White Paper Netfinity Technology Center
Netfinity White Paper Netfinity Technology Center Rack Storage Expansion Enclosure Planning Guide Abstract This paper is designed for use by Pre-Sales technical marketing representatives. This includes
More informationNortel Communication Server 1000 Fiber Remote Multi-IPE Interface Fundamentals. Release: 7.0 Document Revision:
Fiber Remote Multi-IPE Interface Fundamentals Release: 7.0 Document Revision: 04.01 www.nortel.com NN43021-556. . Release: 7.0 Publication: NN43021-556 Document release date: 4 June 2010 While the information
More informationInstalling the Cisco AS5400XM Universal Gateway
CHAPTER 3 Installing the Cisco AS5400XM Universal Gateway This chapter guides you through the installation of the Cisco AS5400XM universal gateway and includes the following sections: Setting Up the Chassis,
More informationAT&T Virtual Private Network Service (VPN) and AT&T VPN Express
AT&T Virtual Private Network Service (VPN) and AT&T VPN Express Site preparation guide This guide is designed to assist local on-site contacts to understand what you will need to accomplish in preparation
More informationRS-232 Industrial Media Converter
USER GUIDE The leader in rugged fiber optic technology. U-151 2018C-0327 Industrial Media Converter COMPACT, RUGGED & TEMPERATURE HARDENED Introduction This Industrial Serial Data media converter transports
More informationHigh Frequency Power Supply Board IS200HFPRG_A
g GEI-100312 GE Industrial Systems High Frequency Power Supply Board IS200HFPRG_A Safety Symbol Legend Indicates a procedure or condition that, if not strictly observed, could result in personal injury
More informationSPECIAL SPECIFICATION 1528 Add/Drop Multiplexor/Demultiplexor
1993 Specifications CSJ 3136-01-096 SPECIAL SPECIFICATION 1528 Add/Drop Multiplexor/Demultiplexor 1. Description. This Item shall govern for the furnishing and installation of a SONET Add/Drop Multiplexor/Demultiplexor
More informationN3240 Installation and Setup Instructions
IBM System Storage N3240 Installation and Setup Instructions Covering the N3240 model GA32-2203-01 Notices Mail comments to: IBM Corporation Attention Department GZW 9000 South Rita Road Tucson, AZ 85744-0001
More informationGB of cache memory per controller to DS4800 controllers with 8 GB of cache memory per controller.
IBM System Storage DS4800 Controller Cache Upgrade Kit Instructions Attention: IBM has renamed some FAStT family products. FAStT EXP100 has been renamed DS4000 EXP100, FAStT EXP700 has been renamed DS4000
More informationSwitchBlade Switch Controller Quick Install Guide
SwitchBlade Switch Controller Quick Install Guide SwitchBlade Switch Controller Quick Install Guide Document Number. Copyright 2002-2005 Allied Telesyn International, Corp. 19800 North Creek Parkway, Suite
More informationFOMi-40 Fiber Optic Modem with Remote Management
Data Sheet FOMi-40 Provides a secure and long-range data link of up to 100 km (62 mi) Selectable data rates from 56 to 2048 kbps Multimode or single mode operation Extended transmission range up to 100
More informationMeridian 1 Fiber Remote Multi-IPE Interface Description, installation, and maintenance
Meridian 1 Description, installation, and maintenance Document Number: 553-3001-022 Document Release: Standard 3.00 Date: April 2000 Year Publish FCC TM Copyright 1996-2000 Nortel Networks All Rights Reserved
More informationShelf and Backplane Hardware
CHAPTER 1 Shelf and Backplane Hardware This chapter provides a description of Cisco ONS 15600 SDH shelf and backplane hardware. Card and cable descriptions are provided in Chapter 2, Card Reference. To
More informationLSX Optical Distribution Frame
LSX Optical Distribution Frame Introduction...79 Things to Consider When Ordering...80 Fiber Distributing Frame...81 Preterminated Fiber Termination Panels with Multifiber Cable-IFC..82 Adapter-Only Fiber
More informationOptimux-4T1 Four-Channel T1 Multiplexer
Data Sheet Optimux-4T1 Any Traffic Over Fiber Multiplexes four T1 channels over a fiber optics link with various fiber interfaces: multimode, single-mode (up to 120 km), and single-mode over single fiber
More informationRack Mounted Products
SRS3000 Distribution Sub-Rack Prysmian Part Number: See Below The SRS3000 Distribution Sub-Rack is a modular sub-rack available in a variety of configurations for integration into 9 / ETSI / ANSI racks,
More informationSpec Sheet. OmniReach FTTX Solutions DLX Fiber Optic Connector
ADC s is a Next Generation hardened fiber optic connector designed to provide a cost-effective solution for connecting Outside Plant (OSP) fiber networks. The DLX connector is a miniature hardened connector
More informationOwner s Manual. Isolate. Restore. Inspire! Power Conditioners Audio / Video Power Isolation Units Rack Mount / Consumer Series
Owner s Manual 19 Pro Series Rack Mount (RK) Faceplate Isolate. 17 Consumer Series (C) Faceplate Available in Black (B) and Silver (S) Colours Restore. Power Conditioners Audio / Video Power Isolation
More informationA.1 Cisco ONS CL Shelf Specifications. This section includes hardware and software specifications.
APPENDIX A Note The terms "Unidirectional Path Switched Ring" and "UPSR" may appear in Cisco literature. These terms do not refer to using Cisco ONS 15xxx products in a unidirectional path switched ring
More informationInstruction Manual RT-91685SL RR-91685SL Sixteen Channel Video Multiplexer With Two Bi-directional Data Channels
Instruction Manual RT-91685SL RR-91685SL Sixteen Channel Video Multiplexer With Two Bi-directional Data Channels Copyright 2007, American Fibertek, Inc. 0501JD Table of Contents Functional Description...3
More informationDatasheet. Fiber Optic Modular Patch Panel Features
Features Very high density, supports up to 24 duplex LC adapters (48 fibers), MT-RJ adapters (48 fibers) and simplex SC adapters (24 fibers) in 1U of rack space Pullout drawer enables ease of access to
More informationMechanical. Chassis CHAPTER
CHAPTER 2 This section describes the mechanical design of the MGX 8230, including chassis, power options, midplane, cabling, and EMI. Chassis The MGX 8230 is a 14-slot chassis with horizontally mounted
More informationLoop-O9330 Fiber Optical Mux
Loop-O9330 Fiber Optical Mux Features Up to 16 E1 links and one 100Mbps ethernet link on one fiber Auto Laser Shutdown function is user configurable Supports 10/100M Ethernet Bridge plug-in card (Optional)
More informationDS-1H05 Ethernet-over-Coax Extender. User Manual
DS-1H05 Ethernet-over-Coax Extender User Manual Thank you for purchasing our product. If there is any question or request, please do not hesitate to contact dealer. This manual is applicable to DS-1H05-T,
More informationCables and Connectors
Module 2 Cables and Connectors Twisted Pair Two wires that carry the data signals (one conductor carries a positive signal; one carries a negative signal). Two wires are twisted to reduce the effects of
More informationJunos WebApp Secure 5.0 Hardware Guide
Junos WebApp Secure 5.0 Hardware Guide Junos WebApp Secure 5.0 Hardware Guide This document contains a specification for the MWS1000 hardware appliance, as well as instructions for installation into a
More informationInstalling the Cisco MDS 9020 Fabric Switch
CHAPTER 2 This chapter describes how to install the Cisco MDS 9020 Fabric Switch and its components, and it includes the following information: Pre-Installation, page 2-2 Installing the Switch in a Cabinet
More informationN3220 Installation and Setup Instructions
IBM System Storage N3220 Installation and Setup Instructions Covering the N3220 model GA32-2202-01 Notices Mail comments to: IBM Corporation Attention Department GZW 9000 South Rita Road Tucson, AZ 85744-0001
More informationINSTALLATION INSTRUCTIONS FOR THE BV10-100/1000
INSTALLATION INSTRUCTIONS FOR THE BV10-100/1000 This document describes the basic steps for installing your BV10-100 or BV10-1000. For detailed information about the BV10-100/1000, see the Ethernet Performance
More informationOPTI-6100 Series Optical Access Multi-Service Provisioning Platform (MSPP)
OPTI-6100 Series Optical Access Multi-Service Provisioning Platform (MSPP) OPTI-6100 Series A high-density, compact, multi-service optical access and aggregation platform. Service providers globally have
More informationF8016. Fiber Modem for up to 4E1 /8E1/12E1/16E1 + RS232+Ethernet+ optional V.35/QFXS/QFXO
F8016 Fiber Modem for up to 4E1 /8E1/12E1/16E1 + RS232+Ethernet+ optional V.35/QFXS/QFXO Description The fiber transmission platform is a fiber optic multiplexer with a fully new designing concept to challenge
More informationCisco CRS 16-Slot Chassis Power Systems
This chapter includes the following sections: Power specifications are provided in Technical Specifications Power Systems Overview, on page 1 Power Component Information Common to the Two Types of Power
More informationLVN5200A-R2, rev. 1, Hardware Installation Guide
LVN5200A-R2 LVN5250A-R2 LVN5200A-R2, rev. 1, Hardware Installation Guide Customer Support Information Order toll-free in the U.S.: Call 877-877-BBOX (outside U.S. call 724-746-5500) FREE technical support
More informationSpecification Sheet: HT SERIES
Specification Sheet: HT SERIES HT Series: High Specification 19 Enclosures Hi-tech Series of 19 enclosures, supplied in self assembly (flat pack) format for ease of transportation and storage. Manufactured
More informationInstalling the Cisco 2524 and Cisco 2525 Routers
CHAPTER 3 Installing the Cisco 2524 and Cisco 2525 Routers This chapter guides you through the installation of the Cisco 2524 and Cisco 2525 routers and includes the following sections: Required Tools
More informationDatasheet. Multi-Service Access Platform OPCOM3500E-12. OPCOM3500E-12 Feature. Raisecom Technology Co., Ltd.
Multi-Service Access Platform OPCOM3500E-12 OPCOM3500E-12 Feature Overview OPCOM3500E MSAP is carrier-class Multi-Service Access Platform, and designed to enable establishment of service-integrated for
More informationUnpacking an Epica Distribution Matrix
an Epica Distribution Matrix An Epica Distribution Matrix is shipped with one enclosure in each palleted box. Each box contains one of each of the following items (invoices are sent separately): Power
More informationVERTIV VR RACK. Selection Guide
VERTIV VR RACK Selection Guide VERTIV VR RACK Rapid Deployments Everywhere You Operate Standardize your deployments around the world and bring them online faster with the Vertiv VR rack. The Vertiv VR
More informationSerial ATA Hot Swap Drive Cage Upgrade Kit for: Intel Server Chassis SC5200 Intel Server Chassis SC5250-E
Serial ATA Hot Swap Drive Cage Upgrade Kit for: Intel Server Chassis SC5200 Intel Server Chassis SC5250-E A Guide for Technically Qualified Assemblers of Intel Identified Subassemblies/Products Order Number:
More informationThe T-BERD 8000 Transport Module SONET, T-Carrier, and Ethernet Test Module for the T-BERD 8000
ACTERNA TEST & MEASUREMENT SOLUTIONS The Transport Module SONET, T-Carrier, and Ethernet Test Module for the Key Features Optical testing at 155 Mb/s, 622 Mb/s, 2.5 Gb/s, and 10 Gb/s SDH/SONET T-Carrier
More informationGmux Modular TDMoIP Gateway FEATURES
FEATURES Carrier-class modular TDMoIP gateway, extending high capacity TDM traffic over packet-switched networks (PSNs) Operates opposite other members of RAD s TDMoIP family of products, offering a complete
More informationCA-A480-A Elevator Controller. Reference & Installation Manual
CA-A480-A Elevator Controller Reference & Installation Manual TABLE OF CONTENTS INTRODUCTION.................................................................. 4 Introduction.............................................................................................
More informationOPTera Long Haul 1600 Optical Line System
Technical Information Bulletin Optical Line System offers multiservice, high-capacity backbone transport solutions The growth in Internet Protocol (IP) services has fueled demand for an efficient, manageable
More information8-Port Unchannelized E3/T3 Line Card Overview
CHAPTER 8-Port Unchannelized E/T Line Card Overview This chapter describes the Cisco series 8-port unchannelized E/T line card (referred to as the 8-port unchannelized E/T line card), and contains the
More informationSPECIAL SPECIFICATION 1252 System Control Unit Console
1993 Specifications CSJ 0924-06-147, etc. SPECIAL SPECIFICATION 1252 System Control Unit Console 1. Description. This Item shall govern for the furnishing and installation of system control unit (SCU)
More informationIntelligent Channel Bank Shelf
Telecommunications Group Section 360-080-204 Equipment Issue 4 Third Printing, August 2006 360-80 Intelligent Channel Bank Shelf CONTENTS PAGE Part 1. GENERAL.............................................................................
More informationCisco CRS Carrier Routing System 16-Slot Line Card Chassis Router Overview
Cisco CRS Carrier Routing System 16-Slot Line Card Chassis Router Overview This chapter includes the following sections: About the CRS 16-Slot Line Card Chassis, on page 1 Chassis Components, on page 2
More informationInstallation Job Aid for Ethernet Routing Switch 3600 Series
Installation Job Aid for Ethernet Routing Switch 3600 Series Notices NN47213-303 Issue 03.01 November 2017 Notice paragraphs alert you about issues that require your attention. Following are descriptions
More information10 Gigabit Ethernet Copper-to-Fiber Media Converter - Open SFP+ - Managed
10 Gigabit Ethernet Copper-to-Fiber Media Converter - Open SFP+ - Managed Product ID: ET10GSFP This 10GbE fiber media converter lets you scale your network using the 10Gb SFP+ transceiver that best suits
More informationIndoor Protected Entrance Terminal 4588 Series
Indoor Protected Entrance Terminal 4588 Series Instructions Underwriters Laboratories (UL) Listed September 2003 78-8135-1209-8-A 1.0 General The 3M Indoor Protected Entrance Terminal (PET) 4588 Series
More informationa step ahead SunSet 10G SONET and SDH Testing in a Single Handheld Unit
a step ahead SunSet 10G SONET and SDH Testing in a Single Handheld Unit Advanced SONET and SDH Transmission Testing & Analysis in a Handheld Set It's not magic; it's Sunrise Telecom technology. Revolutionizing
More informationAT&T Virtual Private Network Service (VPN) and AT&T VPN Express
AT&T Virtual Private Network Service (VPN) and AT&T VPN Express Site Preparation Guide 2017 AT&T Intellectual Property. All rights reserved. AT&T, Globe logo, Mobilizing Your World and DIRECTV are registered
More informationTower to Rack and Rack to Tower System Conversion Guide
Tower to Rack and Rack to Tower System Conversion Guide HP Workstation zx6000 HP Server rx2600 Manufacturing Part Number : A7857-90017 Edition E0802 Copyright 2002 Hewlett-Packard Company. Legal Notices
More informationWSP OC-n Optical Circuit Testing Standard
OC-n Optical Circuit Testing Standard Copyright Notice Copyright 2002 Windstream Incorporated. All rights reserved. The entire contents of this document are protected under the United States copyright
More informationVertiv VR Rack 1.0 GENERAL
1.1 SUMMARY Vertiv VR Rack Guide Specifications 1.0 GENERAL This specification defines the mechanical characteristics and requirements for the Vertiv VR Rack. A series of adaptive and scalable electronic
More informationMaintaining E-Series Routers
Maintaining E-Series Routers 9 This chapter lists the tools, items, and steps needed for installing and uninstalling E-series components. Other maintenance procedures must be performed by an authorized
More informationCard Protection. 7.1 Electrical Card Protection CHAPTER
CHAPTER 7 Card ion This chapter explains the Cisco ONS 15454 card protection configurations. To provision card protection, refer to the Cisco ONS 15454 Procedure Guide. Chapter topics include: 7.1 Electrical
More informationRack Mounted Products
SRS4000 Distribution Sub-Rack Prysmian Part Number: See Below The SRS4000 Distribution Sub-Rack is a modular sub-rack available in a variety of configurations for integration into 19 / ETSI / ANSI racks,
More information1993 Specifications CSJ SPECIAL SPECIFICATION ITEM Transportation Management Console
1993 Specifications CSJ 0598-01-057 1.0 Description SPECIAL SPECIFICATION ITEM 6398 Transportation Management Console This Item shall govern for the furnishing and installation of Transportation Management
More informationRoom unit with PPS2 interface
1 626 Room unit with PPS2 interface for use with: controllers with a PPS2 interface QAA88.3 Room temperature measurement Key buttons for adjustment of the room temperature setpoint Key buttons for operating
More informationSPOS (Station Point of Sale) 200. SFTP (Station Fare Transaction Processor) 35. CQD (Card Query Device) 35. HCR (Handheld Card Reader) Cradles 120
DESIGN GUIDELINES PRESTO INSTALLATION & CONNECTIVITY PAGE 1 of 4 ELECTRICAL CONNECTIVITY AND WIRING Communications Conduits Conduits designated for Presto equipment data wiring shall be clearly identified
More informationPower Supply Installation
Power Supply Module Overview, on page Installation Guidelines, on page 4 Installing or Replacing an AC Power Supply, on page 6 Installing a DC Power Supply, on page 7 Finding the Power Supply Module Serial
More information