1 SOYAL ACCESS CONTROL SYSTEM AR- (E/EF) V0 Contents Product Terminal Cables Tools Accessories Option P P Flat Head Cap Philips Tapping Screw: x0 Security Torx: Mx0 AR-(E) AR-(EF) P P P Security Torx Wrenches Rubber Pad RJ socket TCP/IP Module Installation Peel off screw rubber Peel off frame rubber Peel off screw hole rubbers and frame rubber from rubber pad Put screw rubbers on the back side of the mounting plate and pull the cables from the square hole of the mounting plate. Put a frame rubber on the frame groove of body Connect the terminal cables to the body and attach the body to the mounting plate. Assemble the covers with the Allen key and screws (accessories supplied). Turn on the power and LED will light and beep will sound. Put on/take off together Frame Rubber Screws Rubber Left LED Descrption Right LED Descrption Blue Arming / Blue LED Green Power-on/Stand-by Input (Active High) /OK Yellow Yellow LED Input (Active High) While power on the device, hands off the touch panel for 0 sec. to make sure a successful activation. Front Panel & Indicator 9 0 Red Best Reading Area Error/Alarm Connector Table CN CN CN9 CN CN Cable: P CN Blue White ()DCVAmp Lock Relay Purple White ()DCVAmp Common--Point White ()DCVAmp Door Contact Orange Negative Trigger Input Exit Switch Purple Negative Trigger Input Transistor Output Max. /00mA Alarm Relay Gray (Open Collector Active Low) Thick Red DC Power Thick Black DC 0V Cable: P CN DI White Reserved Beeper Pink Beeper Output V/00mA, Low LED Yellow Red LED Output V/0mA, Max Brown Green LED Output V/0mA, Max Door Output Transistor Output Max. /00mA Blue White (Open Collector Active Low) Wiegand Thin Green Wiegand DAT: 0 Input Thin Blue Wiegand DAT: Input WG Door Contact Orange Negative Trigger Input WG Exit Switch 9 Purple Negative Trigger Input 9 CN CN CN Cable: P CN Orange White Net - TX+ TCP/IP Output Orange Net - TX- Green White Net - RX+ Gerrn Net - RX Cable: P CN RS- for Lift Thick Green RS-(B-) Thick Blue RS-(A+) Cable: P CN Red Anti-Tamper Orange Switch Yellow Cable: P CN Power Red DC Output Security trigger signal Purple Security trigger signal Output Arming Red White Arming Output Duress Yellow White Duress Output Cable: P CN9/CN Blue CLK Red DC V TTL Output Orange RX White TE Yellow TX Black DC 0V

2 Biometrics Device Access controller print V0 Notice.Tubing: The communication wires and power line should NOT be bound in the same conduit or tubing..wire selection: Use AWG - Shielded Twist Pair to avoid star wiring..power supply: Don t equip controller and lock with the same power supply. The power for controller may be unstable when the lock is activating, that may make the controller malfunction. The standard installation: Door relay and lock use the same power supply, and controller use independent power supply. Wiring Diagram Connect AR-Hto Electric Bolt E Electric Bolt P PB Exit Switch DC Connect to Magnet Lock Magnet Lock PB P DC DC DC Connect to Electric Strike Electric Strike DC Connect to Door Contact DC Alarm P PB P Door Contact ALM CTL Relay Outpot Module DC P DDR P PB (BZ IN) P PB (RLED IN) P SENSOR (GLED IN) P DURESS (WG 0 OUT) P ARMING OUT (WG OUT) ACC90 WGoutput P Strengthen security with Digital Relay Board Electric Bolt DC CTL PB Digital Relay Board P BZ RLED GLED Door Output WG 0 WG DS PB DC AR-(E/EF)become WG mode ( 0 ) ACC90 Master Reader E CTL BZ RLED GLED WG 0 WG DC Connect to Reader Exit Switch DC P BZ RLED GLED Door Output WG 0 WG DS PB P Door Contact Door Contact. When AR-(E/EF)become WG mode,it can be used with any controllers.. AR-(E/EF)support Anti-pass-back by finger or card. DC Using Rule : : Both AR-(EF) Master mode and AR-(EF) WG mode must store all the same FP data and real or visual card number. Card : Can pass WG message to controller.

3 SOYAL ACCESS CONTROL SYSTEM AR- (E/EF) V0 Adding and Deleting Tag Add Single Tag or Random tags Input (or Master Code) 9 UUUUU 0000 Present the tag(s) with (single tag or random numbered cards one by one) Done [e.g.] readom cards with user addresses No. 00 and No. 0: Access programming mode Present the tags one by one Done Add the Sequential tags Input (or Master Code) 9 UUUUU QQQQQ Present the tags (Present the tag with the lowest number first.) OK [e.g.] User Address NO.0 to NO.0 have 0 pcs of sequential tags:(~): Access programming mode Close Tag into RF Area(only use the tag NO.) OK Delete a Single Tag Input (or Master Code) 0 SSSSS 9 EEEEE [e.g.] Delete User Address: 000 Access programming mode Delete a batch of Tags Input (or Master Code) 0 SSSSS 9 EEEEE [e.g.] Delete User Address: 000~00 Access programming mode Delete All Tags Input (or Master Code) 9 9 Tag Information CARD CODE SITE CODE Programming A. Entering and Exiting Programming Mode Entering Input or PPPPPP [e.g.] The Default Value=, if already changed the Master Code=, input Access programming mode Exiting Input CARD CODE SITE CODE Changing the Master Code Access programming mode 09 PPPPPPRRRRRR [Input the -digit new master code twice.] [e.g.] If want to changing the Master Code=, input 09 B. Changing the Node ID of Reader Access programming mode 00 NNN MMM AAA [NNN= Node ID: 000~; MMM=AR-(E/EF)Door NO.:~; AAA=WG Reader Door NO.:~ C. Anti-pass-back Usually, anti-pass-back is commonly applied to parking areas in order to prevent from multi-entry with one card at a time, or somewhere wants to monitor not only the access but also exit condition. Enable device Access programming mode 0 U DDD U= Enable target unit(0=ar-(e/ef),=reader) [Please refer to function default value for details.] [e.g.] If the AR-(E/EF)set to exit reader, WG Reader set to access reader. Access programming mode [Please refer to function default value for details.] Enable card user Access programming mode SSSSS EEEEE P SSSSS= starting user address; EEEEE= ending user address [P=0 Enable/ P= Disable/ P= Reset] [e.g.] User address from 00 to 00 enable the anti-pass-back function: D. Auto Open Zone Door will keep opening after first man flashing card. When the reader is stand-alone, supporting only sets of auto-open zone by device setting. Auto-open zone can extend up to unlimited sets by Networking. Enable/Disable auto open zone Access programming mode 0 U DDD U= Enable target unit(0=ar-(e/ef),=reader) [Please refer to function default value for details.] [e.g.] If the AR-AR-(E/EF)set to Enable aut open zone. Access programming mode [Please refer to function default value for details.] Enable/Disable auto open door without presenting card Access programming mode U DDD U= Enable target unit(0=ar-(e/ef),=reader) [Please refer to function default value for details.] [e.g.] If the WG Reader set to Enable aut open door without presenting card. Access programming mode [Please refer to function default value for details.] Setting up access time Access programming mode 0 MW NN HHMMhhmm H [M=AR-(E/EF); W=Reader(0=disable,=enable); NN: sets of auto-open zone (NN=00~); HHMMhhmm=Starting time to ending time; H= days of week + Holiday (F= 0: disable; : enable)] [e.g.] AR-(E/EF)(without WG reader), to set second time zone which could be passed only at 9:0am to :0pm on Mon, Wed and Fri. Access programming mode setting is completed

4 Biometrics Device Access controller print V0 E. Lift control Connect with AR-0ROB to control floors which the user will be able to access. [BAUD900] Please refer to below floor chart Single floor Set Floor Access programming mode UUUUU LL (G) L L L L L L L L UUUU=User Address LL=Floor number (0~ floor) 0 [e.g.] User address NO. only can reach the elevator to the th floor: 000 Multi floors 0 9 Access programming mode UUUUU G LLLLLLLL 0 9 [UUUUU=User address G: sets of lift control (Input: 0~) LLLLLLLL: 0 9 floors setting (L=0=Disable, L==Enable) 0 9 [e.g.] User address NO. can reach only the th and 0th floor: Access programming mode OK (Please refer to floor chart as right.) 0 9 F. Setting Up the Arming Conditions: Application:. Arming is enabled. Door open too long: Door is open longer than door relay time plus door close time..alarm system connected. Force open (Opened without a valid user card): Access by force or illegal procedure. Enable Arming status:. Door position abnormal: Arming is enabled and the power is suddenly off then on. Standby Mode Card only Card or Passcode Card and Passcode Enable all devices Enable particular device Input digit user address Input Induct valid card Input digit pass Induct valid card Input digit Induct valid card Input digit digit pass code Input digits code Input digits arming arming code arming code U or arming code or U code or U Enter Program Mode Enable all devices: Access programming mode Enable particular device: Access programming mode U Disable Arming status: Standby Mode Card only Disable all devices Induct valid card Input digit arming code 9 Disable particular device Induct valid card Input digit arming code U or Factory default armingcode is:. U=Reader unit (0=AR-(E/EF), =WG Reader). G. Adding / Deleting print Adding Access programming mode 9 F UUUUU Place your finger on the sensor [F== Adding data; F== Adding data; UUUUU= User address] How to add a finger data: Adding print Bi Di Bi Di (By DO) Adding print (By DO) Adding print (By DO) Bi Di Bi Bi Di Bi Card or Passcode Card and Passcode Input digit user address Input Induct valid card Input digit pass digit pass code Input digits code Input digits arming arming code 9 or U code 9 or U Di Bi Long Bi Bi Di Bi Di Bi Di Bi Long Bi Bi Di Bi Di Bi If you hear continuous "beep..." sounds when you place finger on the sensor, please release your finger from the sensor. Deleting Deleting All Access programming mode 9 0 UUUUU Access programming mode UUUUU= User address H. Enable/Disable Skip /Tag Access programming mode 0 F NNNNN EEEEE (Please consult detail command on page.) NNNNN=starting user address Command Setting Software Setting Access Mode Way EEEEE= ending user address 0 NNNNN EEEEE Just fingerprint FP first and then Tag First Then F=+(Default Value) 0 NNNNN EEEEE Just card control 0 0 NNNNN EEEEE Just fingerprint FP only or Tag only 0 NNNNN EEEEE Just card control or I. Adding / Deleting print. For dual-fingerprint sensor module version, capactive sensor module is the only enabled way for enrolling FP.. For dual-fingerprint sensor module version, user just can select one of fingerprint sensor for identification and can't put two fingerprints to different sensor at the same time.. Extra WG keypad panel is needed for adding card or downloading data connected to PC.. Each finger need to be collected times enrolling for AR-(E/EF). J. The process of FP identification. While attached a finger on biometric sensor, there is a beep sound for starting the scanner. Then, please don't move your finger until the AR-(EF) makes another beep sound.. If there is a -beep sound after user gets access by FP, the FP data shall be reset by command 9*9*99999# under the programming mode. Bi Long Bi Long Bi Long Bi Repeat

5 SOYAL ACCESS CONTROL SYSTEM AR- (E/EF) V0 Restoring Factory Settings Reset all device parameters and user card data Reset all device parameters and user card data: Use the command: Press IP Reset Button of main board for few seconds,then IP and all device parameters will reset. (Reference to picture) Access programming mode After reset, you will hear the long reminder sound,and wait until the Use the Button on the PCB: sound disappear. Resupply the power to device will restore factory setting. please refer to [ DDD ] command to reopen. Reset all user card data: Deleting All print: Access programming mode 9 9 Access programming mode Firmware Upgrade Get the upgrade software from CCTV CORE or our distributor and run UdpUpdater Execute the software The software is within CCTV CORE CD or Login the CCTV CORE web to downloads Update the firmware [Please login the CCTV CORE web to download the new ISP. Input the Target Address and Port. [Load F/W] open the documents that have the new ISP Firmware. Click the new ISP Firmware and [Open] it. Click [Update Device] to start the firmware update. Till the screen shown [Firmware Update is Complete]. Select correct " Port".. Select "Node ID" of the device. Input "User Address".. Select the numberof enrolled fingers in assigned path ( FP or FP per User).. Select the device type "AR-(EF)".. Select Save Path in which will save fingerprint data.. Click Enroll, follow pop-up picture and Status bar to enroll FP as below: Connect to Place st finger st time to sensor remove finger Place st finger nd time remove finge Place nd finger st time remove finger Place nd finger st time Save FP data to File Registration Completed. Transfer fingerprint format V9 -> V. Click "SIF FP ",select old AR-EF FP file format. SIF, the system will automatically generate new single FP file format. FP into 0Server folder.fp into 0Server folder. Deleting fingerprint database on the device. Click"Delete All", all print data from device will be deleted completely.

6 Biometrics Device Access controller print V0 IP Setting Open your Web Browser and input factory default IP address: If the IP address of AR-(E/EF)has changed We must enter the new IP address. Page menu Monitor the on-line computer IP Setting Change the Log-in information Current State Online Status is able to monitor and show which computer is linking on Ethernet Module Current IP address of the AR-(E/EF) Log-in User Password When you choose the "Networking Setting" or "User Password" at first. Log-in window will pop out and please input At the Factory Default User name: admin Password: No as default value,so please just press OK to log-in Networking Setting You will find initial IP Address 9... and check MAC Address is the same as sticker on Ethernet Module device. Please revise IP address you want, and then click Update button. After updating the IP, please re-connect the Web Browser by new IP address. User Password Change the log-in password to lock the IP setting of Ethernet Module. The password composes of 0 characters at most, it can be either A~Z or 0~9.

7 SOYAL ACCESS CONTROL SYSTEM AR- (E/EF) V0 Command List (By WG Keyboard) Function Command Exposition Entering programming mode PPPPPP PPPPPP: Master Code, (Default value: ) Exiting programming mode Exiting programming mode and enabling all device into arming status. Including AR-(EF), WG Reader Enabling each device into arming status. U U=Enable target unit (0=AR-(EF), =WG Reader) Node ID setting 00 NNN MMM AAA NNN=Node ID,(00~) MMM=AR-(EF) Door Number,(00~) AAA=WG Reader Door Number,(00~) default value = CCCCCCCCCCCC CCCCCCCCCCCC = 900 IP Address assign (Must power reset) If set to will enable DHCP otherwise will disable DHCP Netmask Gateway assign Door relay time setting 0 U TTT U=Enable target unit (0=AR-(EF), =WG Reader) TTT=Door relay time 000 (Output constantly) 00~00=-00 Sec.;0~09=0.~0.9Sec. Alarm relay time setting 0 TTT TTT=Alarm relay time;000 (Output constantly) 00~00=~00 Sec. Arming delay time setting 0 TTT Base on second, range: 00~ Alarm delay time setting 0 TTT Base on second, range: 00~ Master card setting 0 SSSSS EEEEE SSSSS-EEEEE=00000~999 SSSSS= starting user address; EEEEE= ending user address M=AR-(EF); W=WG Reader (0=disable; =enable) NN= sets of auto-open zone (Range: 00~) Auto-open zone setting HHMMhhmm=staring time to ending time 0 MW NN HHMMhhmm (e.g.: 0000=0:0 to :00) H : days of week -Sun/Mon/Tue/Wed/Thu/Fri/Sat (Input value: 0=disable; =enable) H: Holiday (Input value: 0=disable; =enable) Master code settings 09 PPPPPPRRRRRR PPPPPP= New master code RRRRRR= Repeat the new master code Suspend or delete tags Suspend:0 SSSSS EEEEE :Suspend 9 :Delete Delete: 0 SSSSS 9 EEEEE SSSSS= starting user address; EEEEE= ending user address Recover tag SSSSS EEEEE SSSSS= starting user address; EEEEE= ending user address Setting up Card or PIN mode by user address UUUUU PPPP UUUUU= user address; PPPP=-digit individual PWD (Access mode: Card or PIN) Arming output setting TTT Base on ms, range:~, default value=0, Input 0= Timeless Duress code setting PPPP PPPP=-digit PWD ( ) Default value: Arming PWD setting PPPP PPPP=-digit PWD ( ) Default value: Enabling or Disabling into arming status Card+NNNN NNNN:Arming PWD Enabling or Disabling each device into arming status. Card+NNNN U U=Enable target unit (0=AR-(E/EF), =WG Reader) Enabling all device into arming status. Card+NNNN Disabling all device into arming status. Card+NNNN 9 Door open waiting time U TTT U=Enable target unit (0=AR-(EF), =WG Reader) TTT=Door open waiting time:00~00;default value: sec. Set the card by induction 9 UUUUU QQQQQ UUUUU=user address QQQQQ=Card quantity(0000=continuously inducting) Reader additional setting 0 U DDD U=Enable target unit (0=AR-(E/EF), =WG Reader) DDD=Function default value Lift control setting: multi-doors UUUUU G LLLLLLLL UUUUU=user address;g= sets of lift control(0~); LLLLLLLL= assigned floor (F=0: Disable, : Enable) AR-0RO/ AR-0ROB relay time setting MMM TTT MMM=Node ID of lift controller TTT= relay time: 000~00=~00 sec. Factory setting U DDD U=Enable target unit (0=AR-(E/EF), =WG Reader) DDD:Function default value Real time clock setting YYMMDDHHMMSS YYMMDDHHmmSS: Year/Month/Day/Hour/Min./Sec.

8 Biometrics Device Access controller print V0 Command List (By WG Keyboard) Function Command Exposition Anti-pass-back (Enable user) SSSSS EEEEE P SSSSS= starting user address; EEEEE= ending user address P=0=Enable; P==Disable; P==Initial Lift control setting: single door UUUUU LL UUUUU=user address;ll:floor number(0~ floor) Duress Function and Arming output setting FFF Arming output and Duress function: FFF= 00 (default value) Delete all tag/delete all tag + parameters setting 9 9 / 9 99 Same tag reading interval time TTTT Base on 0ms, range from 0 to 000 Auto ring the clock alarm schedule SS HHMMTT H SS= sets auto alarm schedule, range 0~ HHMM= HH:MM (ex. 00: Ring bell at 0:0) TT=Period of time to ring bell (Base on second, range 0~99 sec.) : days of week -Sun/Mon/Tue/Wed/Thu/Fri/Sat (Input value: 0=disable; =enable) H: Holiday (Input value: 0=disable; =enable) MM= Month of year (0=Jan...0=Oct.) Holiday Setting MMDD F DD= Date of month (0=st day of month) F= 0:Delete ; : Add Enabling or Disabling into Full Access status MW M=AR-(EF) ; W=WG Reader (0=disable; =enable) A=0:AR0RO B=0: 900(default value) RS port function setting :Host (default value) : 900 AB (Needs to be restarted after setting) :LED Panel : 00 :Printer : 00 00=000 -Vein recognition Biometric forms set 00=9000 Optical / Capacitive fingerprint recognition DDD 00=00 Optical fingerprint recognition (Needs to be restarted after setting) 00=00 Capacitive fingerprint recognition 0=00 Optical & Capacitive fingerprint recognition F= : Adding one finger data Adding / Deleting print 9 F UUUUU : Adding two finger data :Adding three finger data 0: Delete Deleting All print UUUUU=user address First 0**NNNNN*EEEEE# Then 0**NNNNN*EEEEE# setting a pair of command Access mode: FP first and then Tag (Default Value) En/Disable Skip /Tag 0 F NNNNN EEEEE First 0*0*NNNNN*EEEEE# Then 0**NNNNN*EEEEE# setting a pair of command Access mode: FP only or Tag only NNNNN= starting user address;eeeee= ending user address Function Default Value 0 U DDD Default Value Function Option Value Application Time Attendance 0: Yes : No 00 Networking Auto Re-lock 0: Disable : Enable 00 Networking/Stand-Alone Auto Open 0: Disable : Enable 00 Networking/Stand-Alone When Access Mode is "Card and PIN", Readers can skip pressing PIN code. 0: Disable : Enable 00 Networking/Stand-Alone Exit by Push Button 0: Disable : Enable 0 Networking/Stand-Alone Enable force Open 0: Slave : Mater 0 Networking As Access/Exit Reader 0: Exit : Access 0 Networking Anti-pass-back 0: Disable : Enable Networking U DDD Default Value Function Option Value Application Enable Egress Beep Sounds 0: Disable : Enable 00 Networking/Stand-Alone Skip Tag after FP Access 0: Disable : Enable 00 Networking/Stand-Alone Enable Arm/Disarm Zone() 0: Disable : Enable 00 Networking/Stand-Alone Reader and controller share the same door relay (only for reader) 0: Disable : Enable 0 Networking/Stand-Alone Free Access Mode 0: Disable : Enable 0 Networking/Stand-Alone Stop Alarm by... 0: None : Push button/door Closed 0 Networking/Stand-Alone Open door immediately without st card presented at auto open zone 0: Disable : Enable Networking/Stand-Alone FFF Default Value Function Option Value Application Expiry User Access Trigger Alarm 0:Disable :Enable 00 Networking/Stand-Alone Auto Reset Anti-pass on TZ Duress Function and Arming output setting 0:Disable 0:Wiegand output :Enable : Arming and Duress Networking/Stand-Alone Networking/Stand-Alone RS- 0ROB:00 HOST: Networking/Stand-Alone LED: 0 PRN: 0 0

AR-881(EF-MT) P4 P5 P6 P7. P7 only provide to the controller that have doorbell function.

AR-881(EF-MT) P4 P5 P6 P7. P7 only provide to the controller that have doorbell function. SOYAL ACCESS CONTROL SYSTEM AR- (EF) V00 Contents Product User Guide Terminal Cables Tools Optional P P P Flat Head Cap Philips Tapping Screw: x0 Security Torx: Mx0 WG keyboard AR-(EF-DO) Installation

More information

SOYAL AR-725 (E-V2) V Contents AR-725 (E-V2-M) Installation AR-725 (E-V2-M) AR-725 (E-V2) AR-725 (X) Parts Description AR-725 (E-V2) AR-725 (X)

SOYAL AR-725 (E-V2) V Contents AR-725 (E-V2-M) Installation AR-725 (E-V2-M) AR-725 (E-V2) AR-725 (X) Parts Description AR-725 (E-V2) AR-725 (X) SOYAL ACCESS CONTROL SYSTEM AR- (E-V) V0 Contents AR- (E-V-M) Products User Guide Terminal Cables Tools P P P c x d x A. B. C. D. P P P P AR- (E-V) Products User Guide Terminal Cables Tools P P P e x A.

More information

ECL-ACC980IP-V2/VP. Contents ECL-ACC980IP-V2. Installation ECL-ACC980IP-V2 ECL-ACC980IP-VP. Parts Description ECL-ACC980IP-VP A. B. C.

ECL-ACC980IP-V2/VP. Contents ECL-ACC980IP-V2. Installation ECL-ACC980IP-V2 ECL-ACC980IP-VP. Parts Description ECL-ACC980IP-VP A. B. C. EC-ACC90IP-/P Contents EC-ACC90IP- Products User Guide Terminal Cables Tools P P P a x A. E. F. P P P P EC-ACC90IP-P Products User Guide Terminal Cables Tools P P P b x A. B. C. D. P P P P c x Parts Description

More information

SOYAL AR-725E-M / AR-725E / AR-725X V Contents AR-725E-M. Installation AR-725E-M AR-725E AR-725X. Parts Description AR-725E AR-725X

SOYAL AR-725E-M / AR-725E / AR-725X V Contents AR-725E-M. Installation AR-725E-M AR-725E AR-725X. Parts Description AR-725E AR-725X SOYAL ACCESS CONTROL SYSTEM AR-E-M / AR-E / AR- 0909 Contents AR-E-M Products User Guide Terminal Cables Tools P P P P c x d x A. B. C. D. P P P P AR-E Products User Guide Terminal Cables Tools P P P P

More information

Biometrics Device Access controller Fingerprint & Finger Vein V Connector Table () Cable: P Wire Application Anti-Tamper Switch Wire Color Red Orange

Biometrics Device Access controller Fingerprint & Finger Vein V Connector Table () Cable: P Wire Application Anti-Tamper Switch Wire Color Red Orange SOYAL ACCESS CONTROL SYSTEM AR- (EF-V) / (EV-V) V Contents AR- (EF-V):Fingerprint Products User Guide Terminal Cables Tools Optional P P P AR- (EV-V):Vein P P P AR-RB Products User Guide Terminal Cables

More information

AR-321 (H) / AR-331 (H)/ AR-721(H) / AR-725 (H) / AR-757 (H)

AR-321 (H) / AR-331 (H)/ AR-721(H) / AR-725 (H) / AR-757 (H) AR- (H) / AR- (H)/ AR-(H) / AR- (H) / AR- (H) SOYAL ACCESS CONTROL SYSTEM V0 Contents AR- (H):Touch-panel Metal Housing Product User Guide Terminal Cables Tools Water proof Strip d x P P P P AR- (H):Touch-panel

More information

SOYAL AR-321H/AR-721H/ AR-725H/AR-757H ACCESS CONTROL SYSTEM. Contents AR-321H [Metal Case] AR-721H. AR-725H [Illuminated Touch-panel] AR-725H-M

SOYAL AR-321H/AR-721H/ AR-725H/AR-757H ACCESS CONTROL SYSTEM. Contents AR-321H [Metal Case] AR-721H. AR-725H [Illuminated Touch-panel] AR-725H-M SOYAL AR-H/AR-H/ AR-H/ ACCESS CONTROL SYSTEM Contents AR-H [Metal Case] Product Water proof Strip d x AR-H Product f x AR-H [Illuminated Touch-panel] AR-H-M Products c x e x A. B. C. D. AR-H Products f

More information

SOYAL AR-321H/AR-331H/ AR-721H/AR-725H/AR-757H ACCESS CONTROL SYSTEM V Contents AR-321H [Touch-panel Metal Housing] 1 Product 2 User Guide 3 Ter

SOYAL AR-321H/AR-331H/ AR-721H/AR-725H/AR-757H ACCESS CONTROL SYSTEM V Contents AR-321H [Touch-panel Metal Housing] 1 Product 2 User Guide 3 Ter SOYAL AR-H/AR-H/ AR-H/AR-H/AR-H ACCESS CONTROL SYSTEM Contents AR-H [Touch-panel Metal Housing] Product User Guide Terminal Cables Water proof Strip d x AR-H [Touch-panel Metal Housing]/ AR-H-S [Metal

More information

Option. AR-701B-X Fit 35mm DIN Rail or Mount directly AR-721K AR-725K AR-331K 1456 RAM. WG 26 / WG 34 Power Supply. YES Power Consumption

Option. AR-701B-X Fit 35mm DIN Rail or Mount directly AR-721K AR-725K AR-331K 1456 RAM. WG 26 / WG 34 Power Supply. YES Power Consumption SOYAL ACCESS CTROL SYSTEM AR-E V0 Contents Product User Guide Panel Mounting Base WG Key-panel Reader Option AR-0B-X Fit mm DIN Rail or Mount directly AR-K AR-K AR-K Option For Stand-alone Command Setting

More information

P4 P5 P6. Security trigger signal 2 Purple Security trigger signal Output 6 Thin Blue Wiegand DAT: 1 Input

P4 P5 P6. Security trigger signal 2 Purple Security trigger signal Output 6 Thin Blue Wiegand DAT: 1 Input SOYAL ACCESS CONTROL SYSTEM AR- (E) / (EF) V Contents AR- (EF):Fingerprint Products User Guide Terminal Cables Tools DO AR- (E) Or MT P P P P P P P P P P P P Water proof Strip Optional Products User Guide

More information

AR-721E-V2 (AR-721E-V2-X) AR-701B-X Fit 35mm DIN Rail or Mount directly 16,000 32,000. Connector CN18 Host TCP/IP. Code Pin Description

AR-721E-V2 (AR-721E-V2-X) AR-701B-X Fit 35mm DIN Rail or Mount directly 16,000 32,000. Connector CN18 Host TCP/IP. Code Pin Description SOYAL ACCESS CTROL SYSTEM AR-E-V V0 Contents Product User Guide Panel Mounting Base (AR-E-V-X) Metal Box (AR-E-V-M) Option Option Specification CPU Memory Power Supply Power Consumption Interface / Baud

More information

Function Menu. 1.Add/Delete. 1. Password 2. Access Mode 3. Extend Options 4. Single Floor 5. Multi Floors 6. Enroll FP 7.

Function Menu. 1.Add/Delete. 1. Password 2. Access Mode 3. Extend Options 4. Single Floor 5. Multi Floors 6. Enroll FP 7. Function Menu 1.Add/Delete 2.User Setting 1. Password 2. Access Mode 3. Extend Options 4. Single Floor 5. Multi Floors 6. Enroll FP 7. Delete FP 1. Add - Card ID 2. Add - RF-learn 3. Suspend - Addr 4.

More information

QUICK START GUIDE. 2.4 Inch Finger Vein Terminal Time Attendance & Access Control

QUICK START GUIDE. 2.4 Inch Finger Vein Terminal Time Attendance & Access Control QUICK START GUIDE 2.4 Inch Finger Vein Terminal Time Attendance & Access Control Version: 1.0 Date: Apr., 2017 1 2.4-Inch TFT LCD USB Storage Device Port Keypad& Card Reader Doorbell & LED Indicator Fingerprint

More information

CV-550SPK V2 Waterproof Keypad/Reader/Controller Installation Instructions

CV-550SPK V2 Waterproof Keypad/Reader/Controller Installation Instructions CV-550SPK V2 Waterproof Keypad/Reader/Controller Installation Instructions Packing List NAME MODEL/SIZE QTY Self tapping screw 0.15 x 1.06 (4mm 27 mm) Rubber plug 0.23 x 1.2 (6mm 30 mm) Star screw driver

More information

Partizan PAB-FC2. Fingerprint scan time Fingerprint identification time. <0.5 s < % <0.0198% Ingress protection rating

Partizan PAB-FC2. Fingerprint scan time Fingerprint identification time. <0.5 s < % <0.0198% Ingress protection rating 1. Features & Technical Parameters 1.1 Features: Partizan PAB-FC2 Metal vandalproof housing Secure and reliable biometric fingerprint recognition Simple for using, wiring can be done by a user without

More information

AR-727H. Technical Manual. 26 August Version 1.00

AR-727H. Technical Manual. 26 August Version 1.00 AR-727H Technical Manual 26 August 2008 Version 1.00 Southern Office: Raytel House Brook Road Rayleigh Essex, SS6 7XH Tel: (01268) 749310 Fax: (01268) 749315 Northern Office: Unit 3 Block 5 Oakbank Industrial

More information

Quick Start Guide. ProBio & ProFAC + ZKBioSecurity 3.0

Quick Start Guide. ProBio & ProFAC + ZKBioSecurity 3.0 Quick Start Guide ProBio & ProFAC + ZKBioSecurity 3.0 CONTENT 1 Safety Precautions...2 On Using Face Recognition Device...3 Device Overview...5 Product Dimensions & Installation...6 Power Connection...7

More information

Finger Vein Access Control device Quick Start Guide Version: 1.0 Date: June USB slot. USB slot

Finger Vein Access Control device Quick Start Guide Version: 1.0 Date: June USB slot. USB slot Overview Fingerprint & Finger Vein Device Front Left Side: Finger Vein Device Touch screen Card reader Fingerprint reader Finger vein reader Finger vein sensor: During registration, after finger touches

More information

Fingerprint Identification Proximity Reader. Quick Installation Guide

Fingerprint Identification Proximity Reader. Quick Installation Guide Fingerprint Identification Proximity Reader Quick Installation Guide 1. WHAT S INCLUDED Please unpack and check the contents of the box. If any of these parts are missing, please contact a nearby distributor

More information

Operation manual For NG BIOSINGLE Version 1.1

Operation manual For NG BIOSINGLE Version 1.1 Operation manual For NG BIOSINGLE Version 1.1 SMART-I ELECTRONICS SYSTEMS PVT. LTD.(An ISO 9001:2008 certified company) R&D, Training & Customer Support Center: First Floor, Arihant Plaza Phase II, Village-Ovala,

More information

Single Door Standalone Access Control User Manual

Single Door Standalone Access Control User Manual Single Door Standalone Access Control User Manual Reading this manual carefully before install and use the device 1. Packing List Name Quantity Remarks Keypad User manual Screw driver Rubber plug Self

More information

CM-110SK Standalone Keypad Installation Instructions

CM-110SK Standalone Keypad Installation Instructions CM-0SK Standalone Keypad Installation Instructions. Packing List Qty Name Remarks 2 2 Keypad User manual Screwdriver Wall plugs Self-tapping screws Torx screw 0.8 x 2.4 Φ(20 mm 60 mm) 0.24 x.2 Φ (6 mm

More information

QUICK START GUIDE. 2.4 Inch TFT Terminal Time Attendance & Access Control

QUICK START GUIDE. 2.4 Inch TFT Terminal Time Attendance & Access Control QUICK START GUIDE 2.4 Inch TFT Terminal Time Attendance & Access Control Safety Precautions The following precautions are to keep user safe and prevent any damage. Please read carefully before installation.

More information

Installation & User Manual

Installation & User Manual Contents Installation Instructions 3 Installation Diagrams 4 System Overview 6 Wiring Diagrams 8 Network Diagrams 9 Operation Instructions Fingerprint Enrollment 12 21 Wi-Enterprise Controller www.transmittersolutionssmart.com

More information

GV-AS Controller. Installation Guide

GV-AS Controller. Installation Guide GV-AS Controller Installation Guide Before attempting to connect or operate this product, please read these instructions carefully and save this manual for future use. 2011 GeoVision, Inc. All rights reserved.

More information

Installation & User Manual V2.08

Installation & User Manual V2.08 YOUR SECURITY IS OUR PRIORITY Other products from GSD Contents Installation Instructions Installation Diagrams System Overview Wiring Diagrams Network Diagrams Operation Instructions Fingerprint Enrollment

More information

AR-727HB-RAY AR-716E-RAY EAR-727HB-RAY Series of Controllers

AR-727HB-RAY AR-716E-RAY EAR-727HB-RAY Series of Controllers AR-727HB-RAY AR-716E-RAY EAR-727HB-RAY Series of Controllers Installation and Programming Guide AR-716E-RAY EAR-727HB-RAY AR-727HB-RAY 10th August 2011 Version 1.00 Southern Office: Raytel House Brook

More information

Standalone Keypad Access Control. User Manual. SS-TS2000 Size:120*80*25 mm

Standalone Keypad Access Control. User Manual. SS-TS2000 Size:120*80*25 mm Standalone Keypad Access Control User Manual SS-TS2000 Size:120*80*25 mm Please read the manual carefully before use this unit 1. Packing List Name Quantity Remarks Keypad 1 User manual 1 Screw driver

More information

SF200. Installation Guide & Quick Start Guide. 2 TFT AC Terminal Version: 1.0 Date: June 2014

SF200. Installation Guide & Quick Start Guide. 2 TFT AC Terminal Version: 1.0 Date: June 2014 SF200 Installation Guide & Quick Start Guide 2 TFT AC Terminal Version: 1.0 Date: June 2014 All design and specification declared are subject to change without notice in advance. Contents Safety Precautions

More information

ACCESS CONTROL QUICK INSTALL GUIDE. tel: +44 (0) fax: +44 (0) web:

ACCESS CONTROL QUICK INSTALL GUIDE. tel: +44 (0) fax: +44 (0) web: ACCESS CONTROL QUICK INSTALL GUIDE tel: +44 (0)1457 874 999 fax: +44 (0)1457 829 201 email: sales@cop-eu.com web: www.cop-eu.com WIRING CONFIGURATION - ACS CONTROLLERS CONNECTIONS Dahua access controllers

More information

Fingerprint Access Control F1. User Manual

Fingerprint Access Control F1. User Manual Fingerprint Access Control F1 User Manual 1. Introduction F1 is a metal shell standalone fingerprint access control, using the America Atmel s MCU, with precise electron circuit and good productive technology.

More information

180 Series Keypad. Handbook. Revision 2.1

180 Series Keypad. Handbook. Revision 2.1 180 Series Keypad Handbook Revision 2.1 Revision History Revision 1.0 Initial release Revision 2.0 Major update with addition of 180-40 Added 180-40 to document and various headings Note regarding unique

More information

F6-Fingerprint. Access Control/Reader. User Manual. F6 - Simplified Instruction. (Master Code) # (Factory default:1234) Enter the Programming Mode

F6-Fingerprint. Access Control/Reader. User Manual. F6 - Simplified Instruction. (Master Code) # (Factory default:1234) Enter the Programming Mode -Fingerprint Access Control/Reader Function Description Enter the Programming Mode - Simplified Instruction Operation (Factory default:1234) Change the Master Code Add Fingerprint User Add Card User Add

More information

CV-110SPK Standalone Keypad/Prox Access Control Installation Instructions

CV-110SPK Standalone Keypad/Prox Access Control Installation Instructions CV-110SPK Standalone Keypad/Prox Access Control Installation Instructions 1. Packing List Qty Name Remarks 1 1 1 2 2 1 Keypad User manual Screwdriver Wall plugs Self-tapping screws Torx screw 0.8 x 2.4

More information

Comfort, the Intelligent Home System. Comfort Fingerprint Reader Interface FPR01

Comfort, the Intelligent Home System. Comfort Fingerprint Reader Interface FPR01 Comfort, the Intelligent Home System Comfort Fingerprint Reader Interface FPR01 Introduction to the Comfort Fingerprint Reader Interface... 1 Specifications... 2 Equipment... 2 Settings... 2 Connections...

More information

W3-H Waterproof Keypad/Reader/Controller

W3-H Waterproof Keypad/Reader/Controller W3-H Waterproof Keypad/Reader/Controller User Manual 1. Packing list Name Quantity Digital Keypad W3-H 1 User Manual 1 Screw Driver Rubber Bungs Self Tapping Screws Diode 1 4 4 1 Manager Card 2 Remark

More information

Quick Start Guide. GV-CS1320 Camera Access Controller

Quick Start Guide. GV-CS1320 Camera Access Controller Quick Start Guide GV-CS1320 Camera Access Controller Thank you for purchasing GV-CS1320 Camera Access Controller. This guide is designed to assist the new user in getting immediate results from the controllers.

More information

Waterproof. Keypad/Reader/Controller

Waterproof. Keypad/Reader/Controller Waterproof Keypad/Reader/Controller User Manual W1-C W3-C User manual 1. Packing List Name Quantity Remarks Digital Keypad-W1-C/W3-C 1 User manual 1 Screw driver 1 Rubber bungs 4 6*27mm, used for fixing

More information

This document mainly introduces the windows and operations of the F18 model 2.4 inch color TFT product.

This document mainly introduces the windows and operations of the F18 model 2.4 inch color TFT product. F18 User Manual Version: 1.0 Date: Dec. 2011 Introduction: This document mainly introduces the windows and operations of the F18 model 2.4 inch color TFT product. About this manual 1. Not all the devices

More information

Wiring Guide EP.NMINI. Version 1.02 Last Updated:

Wiring Guide EP.NMINI. Version 1.02 Last Updated: Wiring Guide EP.NMINI Version 1.02 Last Updated: 14-10-2014 1 Note: See http://www.entrypass.net/ for updates, revisions, and download the latest installation manual There are currently 2 version of EntryPass

More information

2000 Series e/em Style Keypad Installation and Programming Manual

2000 Series e/em Style Keypad Installation and Programming Manual 2000 Series e/em Style Keypad Installation and Programming Manual Document Number: 6054022 Revision: 0 Date: 12/21/06 Table of Contents Table of Contents Section 1: Introduction... 6 1 Product Description...6

More information

Digital Keypad Introduction

Digital Keypad  Introduction K2 Digital Keypad Introduction The K02 uses the latest microprocessor technology to operate door strikes and security systems that require a momentary (timed) or latching dry contact closure. All programming

More information

Safety Precautions How to place the finger Product Contents Product PIN Diagram Product Dimensions Cables and Connectors Installation of Back Plate

Safety Precautions How to place the finger Product Contents Product PIN Diagram Product Dimensions Cables and Connectors Installation of Back Plate www.zkaccess.com Safety Precautions How to place the finger Product Contents Product PIN Diagram Product Dimensions Cables and Connectors Installation of Back Plate Power Connection Ethernet Connection

More information

Instruction Manual. Vogue. Security. Technology. Innovation 2013-V01

Instruction Manual. Vogue. Security. Technology. Innovation 2013-V01 Instruction Manual DH16A-60DTE Model 60 with plastic keypad, stand alone access control DH16A-60DTQE Model 60 with plastic keypad, networked access control 2013-V01 Security Technology Vogue Innovation

More information

Standalone Keypad Access Control. User Manual. Please read the manual carefully before use this unit

Standalone Keypad Access Control. User Manual. Please read the manual carefully before use this unit Standalone Keypad Access Control User Manual Please read the manual carefully before use this unit 1. Packing List Name Quantity Remarks Keypad 1 User manual 1 Screw driver 1 Φ20mm 60mm,Special for keypad

More information

GV-AS/EV Controller. User s Manual

GV-AS/EV Controller. User s Manual GV-AS/EV Controller User s Manual Before attempting to connect or operate this product, please read these instructions carefully and save this manual for future use. AS100.110.120.210.400.410.810-EV48-C

More information

Industrial Serial Device Server

Industrial Serial Device Server 1. Quick Start Guide This quick start guide describes how to install and use the Industrial Serial Device Server. Capable of operating at temperature extremes of -10 C to +60 C, this is the Serial Device

More information

W Series. Color Screen Fingerprint & Card Time Attendance and Access Control W 1 W 2

W Series. Color Screen Fingerprint & Card Time Attendance and Access Control W 1 W 2 W Series Color Screen Fingerprint & Card Time Attendance and Access Control W 1 W 2 W1 & W2 Features * Standard 2.8-inch TFT LCD, 512MB Flash, industrial high speed CPU * Touch keypad & touch active sensor

More information

INSTALLATION GUIDE 2.4 Inch TFT Terminal Time Attendance & Access Control

INSTALLATION GUIDE 2.4 Inch TFT Terminal Time Attendance & Access Control STALLATION GUIDE.4 Inch TFT Terminal Time Attendance & Access Control Optional accessories Safety Precautions The following precautions are to keep user s safe and prevent any damage. Please read carefully

More information

EL-ST100 KEYPAD CONTROLLER

EL-ST100 KEYPAD CONTROLLER WIRING DIAGRAM EL-ST100 KEYPAD CONTROLLER WEATHER-PROOF STANDALONE ACCESS CONTROLLER WITH KEYPAD & PROXIMITY TECHNOLOGY Programming and Installation Manual NOTE: www.elock2u.com ICT at work! Version 3.6

More information

WELCOME. For customer support or any inquiries, please visit our web site at or contact us at

WELCOME. For customer support or any inquiries, please visit our web site at  or contact us at WELCOME Congratulations on purchasing the GBF Smart Four Wire Intercom System. Our factory engineers were the first to enable multiple security cameras being monitored through a smart mobile device and

More information

ACTpro Single Door IP Controller. Operating & Installation Instructions

ACTpro Single Door IP Controller. Operating & Installation Instructions ACTpro 1500 Single Door IP Controller Operating & Installation Instructions 18-00079 Issue 1 This manual refers to the ACTpro 1500 a TCP/IP based control unit supporting up to 32 doors. Access Control

More information

F18. Fingerprint capacity 3,000 Transaction capacity 100,000 Hardware Platform ZK 6001, 400Mhz 64M Flash, 32MSDRAM. Identification speed

F18. Fingerprint capacity 3,000 Transaction capacity 100,000 Hardware Platform ZK 6001, 400Mhz 64M Flash, 32MSDRAM. Identification speed F18 Features: 1. 2.4 TFT LCD color screen 2. Standard Wiegand Input and Output interfaces are compatible with most all 3 rd party 26 bit Wiegand readers and access control panels. 3. USB HOST port makes

More information

Fingerprint Door Lock OPERATOR S MANUAL

Fingerprint Door Lock OPERATOR S MANUAL Fingerprint Door Lock OPERATOR S MANUAL Notes: Please read this manual carefully before operation. 1 Contents Chapter 1: Introduction 03 1.1 Features 03 1.2 Technical Specification 03 1.3 Fingerprint recognition

More information

Portals 14 What is a portal? 14 Hardware 15 RS232 to RS USB to RS TCP/IP to RS Add a Serial Portal 16 Add a Network portal 16

Portals 14 What is a portal? 14 Hardware 15 RS232 to RS USB to RS TCP/IP to RS Add a Serial Portal 16 Add a Network portal 16 PROS LITE User Manual Version 2.0.0 www.visual-plus.com Table of Contents Getting Started 5 Starting PROS Lite 5 Create a Portal 5 Adding a control panel 6 Adding a user 7 Upload users to a controller

More information

H2i. s u p p o r f i n g e r t e c. c o m. H2i. Simple Fingerprint Door Access & Time Attendance System. User Guide

H2i. s u p p o r f i n g e r t e c. c o m. H2i. Simple Fingerprint Door Access & Time Attendance System. User Guide H2i s u p p o r t @ f i n g e r t e c. c o m H2i Simple Fingerprint Door Access & Time Attendance System User Guide CONTENTS 3-4 Chapter 1 getting started Viewing the User Guide in the Internet Included

More information

EZTAG3 PROXIMITY AND KEYPAD DOOR ENTRY

EZTAG3 PROXIMITY AND KEYPAD DOOR ENTRY EZTAG PROXIMITY AND KEYPAD DOOR ENTRY USER MANUAL www.espuk.com EZTAG Manual_Layout.indd 8//06 5:8:0 System Components Proximity and Reader 0 x Proximity Tags x Hex Key x Plastic wall plug x Countersunk

More information

Wiring Diagram and Programming Instructions for MAW6 Digital Keypad and Proximity Card/F reader

Wiring Diagram and Programming Instructions for MAW6 Digital Keypad and Proximity Card/F reader Wiring Diagram and Programming Instructions for MAW6 Digital Keypad and Proximity Card/F reader www.grantsautomation.com.au grant@grantsautomation.com.au Wiring Diagrams for MAW6 Digital Keypad For Pedestrian

More information

GV-Card Reader. User s Manual

GV-Card Reader. User s Manual GV-Card Reader User s Manual Before attempting to connect or operate this product, please read these instructions carefully and save this manual for future use. READER-B 2016 GeoVision, Inc. All rights

More information

User Manual. Split access control with intelligent secured power supply.

User Manual. Split access control with intelligent secured power supply. User Manual Split access control with intelligent secured power supply. Contents. Introduction, features and specifications. Installation and Wiring Diagram 3. Manager Card Operation 4. User Settings 5.

More information

Fingerprint Door Lock User MANUAL

Fingerprint Door Lock User MANUAL Fingerprint Door Lock User MANUAL Notes: Please read this manual carefully before operation. 0 User Manual AKME LOCK LLC Contents CHAPTER 1: INTRODUCTION... 2 1.1 FEATURES... 2 1.2 TECHNICAL SPECIFICATION...

More information

T-7 FINGERPRINT TERMINAL. HARDWARE USER'S MANUAL Rev 1.1

T-7 FINGERPRINT TERMINAL. HARDWARE USER'S MANUAL Rev 1.1 T-7 FINGERPRINT TERMINAL HARDWARE USER'S MANUAL Rev 1.1 1 Table of Contents 1. INTRODUCTION 1.1 SUPPLIED PART LIST 1.2 ABOUT PEGASUS T-7 1.3 HARDWARE SPECIFICATION 2. PRODUCT OVERVIEW 2.1 COMMUNICATION

More information

Pegasus Equipments Export Limited. Local Contact:

Pegasus Equipments Export Limited. Local Contact: Pegasus Equipments Export Limited Add: #31G, Haiyige, Scienway Palace Science & Technology Industrial Park Shenzhen, China. Tel: +86 755 2658 3464 +86 755 2658 3596 Fax: +86 755 8611 0167 web: www.pegasusexport.com

More information

T9 Fingerprint Machine Hardware User Manual. Date: Version: 1.1

T9 Fingerprint Machine Hardware User Manual. Date: Version: 1.1 T9 Fingerprint Machine Hardware User Manual Date: 2010.07.27 Version: 1.1 (c)2010 Copyright Pegasus Equipments Ltd. All Rights Reserved. 1 Table of Content Introduction... 3 Installation... 3 Menu Structure...

More information

genesis TECHNICAL MANUAL Two-Door Controller GEN-045

genesis TECHNICAL MANUAL Two-Door Controller GEN-045 Two-Door Controller GEN-045 Genesis Electronics Australia Pty Ltd www.genesiselectronics.com.au info@genesiselectronics.com.au Australian Owned, Designed and Manufactured Distributed By:- Genesis reserves

More information

Two-door Access Controller

Two-door Access Controller Two-door Access Controller Quick Start Guide V1.0.0 Preface Overview This document elaborates on structure, installation, interface and wiring of two-door access controller. Symbol Definition The following

More information

KP2000E/EM Series Style Keypad

KP2000E/EM Series Style Keypad 23852973 KP2000E/EM Series Style Keypad Installation and Programming Instructions Models KP2000EXX and KP2000EMXX Specifications Parameter Voltage Requirements Keypad Current Requirements (Max) Relay Contact

More information

GV-AS/EV Controller. User s Manual

GV-AS/EV Controller. User s Manual GV-AS/EV Controller User s Manual Before attempting to connect or operate this product, please read these instructions carefully and save this manual for future use. ASEV-H 2016 GeoVision, Inc. All rights

More information

GV-RK1352 and GV-R1352 Card Reader

GV-RK1352 and GV-R1352 Card Reader GV-RK1352 and GV-R1352 Card Reader The GV-RK1352 and GV-R1352 are card readers designed to recognize identifications cards. GV-RK1352 comes with keypad, allowing it to also recognize PIN codes. Featured

More information

BioPointe Reader Installation Guide

BioPointe Reader Installation Guide BioPointe Reader Installation Guide What s in this Guide Installation Steps 1 Key Parts of the BioPointe Reader 2 Cabling Requirements 3 Power Connection 3 PXL-500W Wiegand Controller Connection 3 Serial

More information

EZ-TAG2 Manual_Layout 5 11/12/ :14 Page 1 U S E R M A N UAL

EZ-TAG2 Manual_Layout 5 11/12/ :14 Page 1 U S E R M A N UAL EZ-TAG2 Manual_Layout 5 11/12/2012 09:14 Page 1 USER MANUAL EZ-TAG2 Manual_Layout 5 11/12/2012 09:14 Page 2 Contents EZ-TAG2 and Back Plate 1 x Security Torx Key 4 x Screws and raw plugs 1 x Marking out

More information

ZAVIO Outdoor IR Mini Dome. Quick Installation Guide

ZAVIO Outdoor IR Mini Dome. Quick Installation Guide ZAVIO Outdoor IR Mini Dome Quick Installation Guide 0 Quick Installation Guide Please follow the installation steps below to set up your IP Camera. Check the package contents with the list below. See P.1

More information

Security at Fingertips

Security at Fingertips Security at Fingertips www.esslsecurity.com Contents 1. Operating Instruction... - 1-1.1 Abbreviated Operating Procedures... - 1-1.2 Introduction to Fingerprint Recognition technology... - 2-1.3 About

More information

VIDI-AC-2CS Access Controller/ Reader

VIDI-AC-2CS Access Controller/ Reader VIDI-AC-2CS Access Controller/ Reader User Manual CONTENTS INTRODUCTION 2 INSTALLATION.4 STANDALONE MODE 6 CONTROLLER MODE.11 WIEGAND READER MODE.. 13 ADVANCE APPLICATION..14 1 INTRODUCTION The VIDI-AC-2CS

More information

User Manual. Before using this device, read and follow all instructions for safety

User Manual. Before using this device, read and follow all instructions for safety User Manual Before using this device, read and follow all instructions for safety Copyrightc 2014 KJTECH Co., Ltd. All rights reserved. It is provided for informational purposes only in this manual. All

More information

SL2000E. Status Output. Electronic Code Lock. Features. Input. Exit Button Input. Introduction. Door Contact Input. Functional Description.

SL2000E. Status Output. Electronic Code Lock. Features. Input. Exit Button Input. Introduction. Door Contact Input. Functional Description. SL2000E Electronic Code Lock Features Door Relay output Status transistor output Aux transistor output Door Contact input Exit Button input INSTALLER code for programming MASTER code for arming/disarming

More information

A-1300 Biometric Access Control System USER'S MANUAL

A-1300 Biometric Access Control System USER'S MANUAL A-1300 Biometric Access Control System USER'S MANUAL Table of Contents 1. General Information... 1 1.0 Notification... 2 1.1 System Overview... 2 1.2 Main Features... 2 1.3 Equipment... 3 2. Basic Concepts...

More information

Two Door Controller GEN-045

Two Door Controller GEN-045 Australian Owned, Designed and Manufactured Two Door Controller GEN-045 Genesis Electronics Australia Pty Ltd www.genesiselectronics.com.au Distributed by: Genesis reserves the right to change or modify

More information

Wiring Guide. EP.NMiNi 2. Version 1.04 Last Updated:

Wiring Guide. EP.NMiNi 2. Version 1.04 Last Updated: Wiring Guide EP.NMiNi 2 Version 1.04 Last Updated: 31-01-2013 Before you begin Technical Support If you cannot find the answer to your question in this manual or in the Help files, we recommend you contact

More information

HL100 Fingerprint Lock User Manual

HL100 Fingerprint Lock User Manual HL100 Fingerprint Lock User Manual Version: 1.0 About This Manual This manual introduces the fingerprint lock interface and menu operations for the HL100. For the fingerprint lock installation, see the

More information

EZTAG3 PROXIMITY AND KEYPAD DOOR ENTRY

EZTAG3 PROXIMITY AND KEYPAD DOOR ENTRY EZTAG Manual.qxp_Layout 0/0/06 :7 Page EZTAG PROXIMITY AND KEYPAD DOOR ENTRY USER MANUAL www.espuk.com EZTAG Manual.qxp_Layout 0/0/06 :7 Page System Components Proximity and Reader 0 x Proximity Tags x

More information

GENERAL QUICK START GUIDE

GENERAL QUICK START GUIDE GENERAL QUICK START GUIDE 2.8InchPalm & Fingerprint Time Attendance & Access Terminal Version: 1.0 Date: May., 2017 Note: The picture and function presented in this manual are only for reference. The following

More information

2.4 inch Color Screen Series User Manual

2.4 inch Color Screen Series User Manual 2.4 inch Color Screen Series User Manual Version: 1.3 Date: June 15, 2013 Introduction: This document mainly introduces interface and operation of 2.4 Inches color products. ALARM INTERNATIONAL SYSTEMS

More information

Installation Guide for PR311SE and PR311SE-BK v1.0 Access Controllers Rev. B

Installation Guide for PR311SE and PR311SE-BK v1.0 Access Controllers Rev. B Installation Guide for PR311SE and PR311SE-BK v1.0 Access Controllers Rev. B Introduction This document contains minimum information that is necessary to properly install the device and to perform its

More information

REX F-0-9 Standalone or Access Controller

REX F-0-9 Standalone or Access Controller REX F-0-9 Standalone or Access Controller Power supply The controller need s external power supply to operate. The Spider W40 power supply is sufficient to power two controllers and two 12V electric strikes

More information

F3102 / F3107 / F3110 / F3115 / F3210 / F3215 PN: 86085K K

F3102 / F3107 / F3110 / F3115 / F3210 / F3215 PN: 86085K K F3102 / F3107 / F3110 / F3115 / F3210 / F3215 86085K3000020 PN: 86085K3000030 Zavio F3102/F3107/F3110/F3115/F3210/F3215 Quick Installation Guide Please follow the installation steps below to set up F3102

More information

Fingerprint Access Standalone User s Manual

Fingerprint Access Standalone User s Manual Fingerprint Access Standalone User s Manual V1.1.1 1 Table of Contents 1 Overview... 1 2 Device Structure and Installation... 2 2.1 Device Structure... 2 2.2 Device Installation... 3 3 System Structure...

More information

FINGERPRINT TERMINAL HARDWARE USER'S MANUAL

FINGERPRINT TERMINAL HARDWARE USER'S MANUAL http://www.epordo.com 1 FINGERPRINT TERMINAL HARDWARE USER'S MANUAL or email us at info@securiticn.com 1 1. INTRODUCTION 1.1 SUPPLIED PART LIST 1.2 ABOUT 1.3 HARDWARE SPECIFICATION 2. PRODUCT OVERVIEW

More information

IPassan Installation guide

IPassan Installation guide IPassan Installation guide 1 Content 1 Overview... 3 1.1 Features... 3 1.2 Hardware... 3 1.2.1 s... 3 1.2.2 Extra modules... 5 1.3 IPassan manager... 7 2 Installation... 7 2.1... 8 2.1.1 Power supply...

More information

HSY-S209 EM Metal waterproof access control system User Manual

HSY-S209 EM Metal waterproof access control system User Manual HSY-S209 EM Metal waterproof access control system User Manual Reading carefully before Install and use this manual 1. Product Profile The product is Contact-less inductive card Metal Password Access Controller,

More information

Startup Guide. NetAXS-123. Version 5.2

Startup Guide. NetAXS-123. Version 5.2 NetAXS-123 Startup Guide Version 5.2 This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2)

More information

KJ-3300 USER MANUAL. KJTech

KJ-3300 USER MANUAL. KJTech KJ-3300 USER MANUAL KJTech QUICK START Beginning QUICK START When beginning the ADMIN (access control manager) should NOT be registered. When the ADMIN is not registered access the menu by pressing ID

More information

W3-M. Metal waterproof standalone access control/reader. User Manual

W3-M. Metal waterproof standalone access control/reader. User Manual W3M Metal waterproof standalone access control/reader User Manual Name Digital Keypad W3M User Manual Screw driver Rubber bungs Selftapping screws Diode 1. Packing List Quantity 1 1 1 4 4 1 Remark 6*27mm,

More information

INSTALLATION GUIDE BioLite Net English Version 2.10 EN BLN V2.10A

INSTALLATION GUIDE BioLite Net English Version 2.10 EN BLN V2.10A www.supremainc.com INSTALLATION GUIDE English Version 2.10 EN 101.00.BLN V2.10A Contents Safety Instructions... 3 Getting Started... 5 Components... 5 Part names and features... 6 Cables and connectors...

More information

BC Digital Keypad. User Manual

BC Digital Keypad. User Manual BC2200 Digital Keypad User Manual Name Digital Keypad BC2200 User manual Screw driver Rubber bungs Self tapping screws Diode 1. Packing List Quantity Remarks 1 1 1 4 Φ6mm 28 mm, used for fixing 4 Φ4mm

More information

400 Fingerprint Door Lock User Manual

400 Fingerprint Door Lock User Manual 400 Fingerprint Door Lock User Manual 1,Specialty Easy to learn, easy to operate To be more useful with LCD MENU To enroll finger or delete finger on lock stand alone directly To be supplied power by battery,

More information

2M IR Mini Dome Quick Installation Guide

2M IR Mini Dome Quick Installation Guide 1 2M IR Mini Dome Quick Installation Guide Please follow the installation steps below to set up 2M IR Mini Dome IP Camera. Check the package contents against the list below. See P.1 Physical overview.

More information

BF-630X/BF-830X WEB SCREEN. Access Control/Time Attendance. User s Manual

BF-630X/BF-830X WEB SCREEN. Access Control/Time Attendance. User s Manual BF-630X/BF-830X Access Control/Time Attendance WEB SCREEN User s Manual Table of Contents CHAPTER 1 INSTALLATION... 2 Requirement...2 Procedure...2 CHAPTER 2 WEB SETUP DESCRIPTION... 3 Login Web...3 Preparation...3

More information

RD-SR2 ACCESS SECURITY PRODUCTS LTD. Proximity Card Reader with Remote Control. User Manual

RD-SR2 ACCESS SECURITY PRODUCTS LTD. Proximity Card Reader with Remote Control. User Manual RD-SR2 Proximity Card Reader with Remote Control User Manual INTRODUCTION The RD-SR2 is a compact, weather resistant multi-function card reader that can be used as a standalone programmable access control

More information

GV-AS200 Controller. Hardware Installation Guide

GV-AS200 Controller. Hardware Installation Guide GV-AS200 Controller Hardware Installation Guide Before attempting to connect or operate this product, please read these instructions carefully and save this manual for future use. 2008 GeoVision, Inc.

More information