1 Certificate bundle from independent testing laboratories for KELine Structured Cabling KELine components Cat.6 A, Cat.7, Cat.7 A

2 Certificate verification step by step On the website of the testing laboratories*: check if the certificate is not fake, created or edited in photoshop check if your supplier is the official distributor and is able to provide support and warranties ensured by the manufacturer check if the purchased product is complient with the product listed in the certificate (label on the product packaging and P/N on the certificate) check if the product has been tested according to the current and relevant srandards ** check if the certificate is valid check if the quality of the mass production is under constant supervision of testing laboratories * ** ISO/IEC 11801:2011 (Ed.2.2) - International standard defining the requirements for structured cabling ANSI/TIA-568-C.2: American national standard defining the requirements for structured cabling

3 Compliance Statement No A Connecting Hardware, Category 6A Company KRUGEL EXIM spol. S r.o. Rybnicna 38/H Bratislava Slovak Republic Product description Screened Category 6 A RJ45 Jack and Patch Panel characterised up to 500 MHz, 100 Ω Product identification KELine RJ45 Jack. Part number: KEJ-C6A-S-10G KELine Patch Panel. Part number: KEP-C6A-S-10G KELine Patch Panel. Part number: KEP-C6A-S-10G-NP Generic cabling and cabling components standards - Category 6 A connector requirements ISO/IEC 11801:2011 (Ed. 2.2) IEC :2010 EN :2011 EN :2007 including amendment A1:2010 ANSI/TIA-568-C.2:2009 including all connector alien crosstalk parameters (PS ANEXT and PS AFEXT) Technical report EC Cabling product ID CS valid until DELTA-T205788, DANAK-19/ May 2014 This product has been tested by EC Cabling Group of DELTA and complies with the electrical requirements of the above specified standards and "Terms and conditions for use of the EC VERIFIED marking on generic cabling products, DQP The testing included measurement of NEXT with a compliant test plug and calculation of all the 14 test cases in both measurement directions. The product takes part in a maintenance of certification schedule, which implies that DELTA EC Cabling performs a quality audit of the manufacturer's production and QA sites. The maintenance testing of the product is performed on a sample basis once a year. This Compliance Statement has been revised. Hørsholm, 7 June 2013 Lars Lindskov Pedersen Test Manager Claude Videt Project Manager DELTA Venlighedsvej 4 Tel Hørsholm Fax Denmark

4 Compliance Statement No A Data Communication Cords, Category 6A Company KRUGEL EXIM spol. s r.o. Rybnicna 38/H Bratislava Slovak Republic Product description Screened Category 6 A RJ45 cords (equipment, patch, and work area) characterised up to 500 MHz Product identification KELine 10Giga patch cables STP Cat.6A, LS0H Part number: KEL-C6A-P-xxx (xxx: denotes length in dm) Generic cabling and cabling components standard - Category 6 A balanced cord requirements ISO/IEC 11801:2011 (Ed. 2.2) EN :2011 EN :2007 including amendment A1:2010 ANSI/TIA-568-C.2:2009 IEC :2010 (Ed. 3.0) (transmission requirements) Technical report EC Cabling product ID Certificate valid until DELTA-T204566, DANAK-19/ March 2014 This product has been tested by EC Cabling Group of DELTA and complies with the requirements of the above specified standards and "Terms and conditions for use of the EC VERIFIED marking on generic cabling products, DQP The product takes part in a maintenance of certification schedule, which implies that EC Cabling performs a sample test of the product once a year. This Compliance Statement has been revised. Hørsholm, 7 June 2013 Lars Lindskov Pedersen Test Manager Claude Videt Project Manager DELTA Venlighedsvej 4 Tel Hørsholm Fax Denmark

5 Compliance Statement No A Data communication cable, Category 6A Company KRUGEL EXIM spol. S r.o. Rybnicna 38/H Bratislava Slovak Republic Product description Screened cable (U/FTP) characterised up to 500 MHz Horizontal floor wiring cable, 100 Ω 4 individually foil screened twisted pairs Flame retardant, halogen free Product identification KELine 10Giga STP Cat. 6A LS0H cable Part number: KE500S23/1E Generic cabling and cabling components standards - Category 6 A cable requirements ISO/IEC 11801:2011 (Ed. 2.2) IEC :2009 (Ed. 2.0) EN :2011 EN :2007 including amendment A1:2010 EN :2010 ANSI/TIA-568-C.2:2009 Standards for flammability, halogen acidity, and smoke performance IEC [1,2]:2004 IEC [1,2] IEC [1,2] Technical report EC Cabling product ID CS valid until DELTA-T205600, DANAK-19/ March 2014 This product has been tested by EC Cabling Group of DELTA and complies with the requirements of the above specified standards and "Terms and conditions for use of the EC VERIFIED marking on generic cabling products, DQP The product takes part in a maintenance of certification schedule, which implies that DELTA EC Cabling performs a quality audit of the manufacturer's production and QA sites. The maintenance testing of the product is performed on a sample basis. This Compliance Statement has been revised Hørsholm, 7 June 2013 Lars Lindskov Pedersen Test Manager Claude Videt Project Manager DELTA Venlighedsvej 4 Tel Hørsholm Fax Denmark

6 Compliance Statement No A Data communication cable, Category 6A Company KRUGEL EXIM spol. s r.o. Rybnicna 38/H Bratislava Slovak Republic Product description Screened cable (U/FTP) characterised up to 500 MHz Horizontal floor wiring cable, 100 Ω 4 individually foil screened twisted pairs Flame retardant, halogen free Product identification KELine 10Giga STP 4x2xAWG MHz, Cat. 6A LS0H Part number: KE550S23/1E Generic cabling and cabling components standards Category 6 A cable requirements ISO/IEC 11801:2011 (Ed. 2.2) IEC :2009 (Ed. 2.0) EN :2011 EN :2007 including amendment A1:2010 FprEN :2011 ANSI/TIA-568-C.2:2009 Standards for flammability, halogen acidity, and smoke performance IEC [1,2]:2004 IEC [1,2] IEC [1,2] Technical report EC Cabling product ID CS valid until DELTA-T204828, DANAK-19/ February 2014 This product has been tested by EC Cabling Group of DELTA and complies with the requirements of the above specified standards and "Terms and conditions for use of the EC VERIFIED marking on generic cabling products, DQP The product takes part in a maintenance of certification schedule, which implies that DELTA EC Cabling performs a quality audit of the manufacturer's production and QA sites. The maintenance testing of the product is performed on a sample basis. This Compliance Statement has been revised. cv Hørsholm, 7 June 2013 Lars Lindskov Pedersen Test Manager Claude Videt Project Manager DELTA Venlighedsvej 4 Tel Hørsholm Fax Denmark

7

8

Product information Patch Cord Cat. 6A, S/FTP, 4P, LSFRZH, gray, RJ45/s- RJ45/s, 1.0 m

Product information Patch Cord Cat. 6A, S/FTP, 4P, LSFRZH, gray, RJ45/s- RJ45/s, 1.0 m Product information Patch Cord Cat. 6A, S/FTP, 4P, LSFRZH, gray, RJ45/s- RJ45/s, 1.0 m R509858 101376015 10 pcs Cable identification: S/FTP Outer jacket: LSFRZH Conductor diameter copper strand: AWG 26/7

More information

Certification for 10G copper cabling

Certification for 10G copper cabling Certification for 10G copper cabling Presented by Eric Lie, Sales Manager 1 Introduction This presentation is intended to provide an overview of the 10GBASE-T requirements for cabling The applicable standards

More information

E-DAT C6A. The compact connection system of course with Cat.6A

E-DAT C6A. The compact connection system of course with Cat.6A E-DAT C6A The compact connection system of course with Cat.6A Intelligent system solution for structured cabling Nowadays the need for high data transfer rates is enormous. This not only applies to public

More information

Product information Patch Cord Cat. 5e, SF/UTP, 4P, LSFRZH, gray, RJ45/s- RJ45/s, 0.5 m

Product information Patch Cord Cat. 5e, SF/UTP, 4P, LSFRZH, gray, RJ45/s- RJ45/s, 0.5 m Product information Patch Cord, SF/UTP, 4P, LSFRZH, gray, RJ45/s- RJ45/s, 0.5 m R305039 101347005 10 Pcs. Cable identification: SF/UTP Outer jacket: LSFRZH Conductor diameter copper strand: AWG 26/7 Screened

More information

Introduction to Key Principles of Telecommunications Cabling

Introduction to Key Principles of Telecommunications Cabling Introduction to Key Principles of Telecommunications Cabling Dimitris Filippou Technical Director, Ltd. IEEE Member, BICSI Country Chair, ELOT Technical Committee TC93 Member, CENELEC TC215 Delegate of

More information

Cat.8 Shielded Field Termination Plug Description

Cat.8 Shielded Field Termination Plug Description Description RiT s CAT8 Shielded field termination plug are cost-effective building blocks for your cabling system. Meticulously engineered to deliver exceptional performance while streamlining installations.

More information

New standards that have led to higher speeds and new cable categories. Mike Gengler Sales Area VP, Asia/Pac & Japan Fluke Networks

New standards that have led to higher speeds and new cable categories. Mike Gengler Sales Area VP, Asia/Pac & Japan Fluke Networks New standards that have led to higher speeds and new cable categories Mike Gengler Sales Area VP, Asia/Pac & Japan Fluke Networks Three Realities of Networking #1 - Networks Never Go Slower Plan for higher

More information

Field-terminated RJ45 connector with housing. Color housing: gray (RAL 7042). Color termination block: red.

Field-terminated RJ45 connector with housing. Color housing: gray (RAL 7042). Color termination block: red. FM45 Connector Cat. 6 A IP20, 4P, TIA 568-A/B, 10x R815651 966704105 10 Stk. 090.7437 / ähnliche Abbildung Instruction manual Field-terminated connector with housing. Color housing: gray (RAL 7042). Color

More information

PANGEN SYSTEM WARRANTY. Warranty Guide

PANGEN SYSTEM WARRANTY. Warranty Guide PANGEN SYSTEM WARRANTY Warranty Guide C2-10270 PANGEN SYSTEMWARRANTY GUIDE PROGRAM OUTLINE TABLE OF CONTENTS: MATERIALS PAGE # Program Outline 2 Table of Contents Warranty Information 3 Introduction &

More information

Cat.8 Shielded Keystone Jack Description

Cat.8 Shielded Keystone Jack Description Description RiT s CAT8 Shielded Keystone Jacks are cost-effective building blocks for your cabling system. Meticulously engineered to deliver exceptional performance while streamlining installations. Phosphor

More information

How new testing standards affect you Singapore, Nov 2009

How new testing standards affect you Singapore, Nov 2009 How new testing standards affect you Singapore, Nov 2009 Adrian Young Sr. Customer Support Engineer In this presentation, we will cover How ANSI/TIA-568-C.2 has consolidated all the different test plugs

More information

CERTIFICATION PLUS SM

CERTIFICATION PLUS SM CERTIFICATION PLUS SM SYSTEM WARRANTY PROGRAM Panduit Warranty Guide PROGRAM OUTLINE TABLE OF CONTENTS: MATERIALS PAGE # Program Outline 2 Table of Contents Warranty Information 3 Introduction & Installation

More information

The Quality Connection. LEONI QuickLine Class E Cabling Solution

The Quality Connection. LEONI QuickLine Class E Cabling Solution The Quality Connection LEONI QuickLine Class E Cabling Solution QuickLine 2 Content Infrastructure & Datacom Solutions from a single source Shielded solution, keystone 4 Shielded solution, punch-down 5

More information

UTP Cat 5e cable (200 MHz) (PVC sheath)

UTP Cat 5e cable (200 MHz) (PVC sheath) JetLan is the only structured cabling system that includes all the passive components required for the installation or adaptation of your data network, as we include all the different types of high performance

More information

HCI 2017 Products Catalogue

HCI 2017 Products Catalogue HCI 27 Products Catalogue Publisher HSING CHAU INDUSTRIAL CO., LTD. 9Fl., No.39, Lane 53, Ruiguang Rd., Neihu District, Taipei City 492, Taiwan Tel: +886-2-8797- Fax: +886-2-8797-2388 Website: www.hci.com.tw

More information

PANGEN INDUSTRIAL AUTOMATION SYSTEM WARRANTY

PANGEN INDUSTRIAL AUTOMATION SYSTEM WARRANTY PANGEN INDUSTRIAL AUTOMATION SYSTEM WARRANTY WARRANTY GUIDE PANGEN INDUSTRIAL AUTOMATION SYSTEM WARRANTY WARRANTY GUIDE PROGRAM OUTLINE TABLE OF CONTENTS: MATERIALS PAGE # Program Outline 2 Table of Contents

More information

Telegärtner Point of View

Telegärtner Point of View Telegärtner Point of View Category 6 A Patch Cords 10 Gigabit per second is the highest data rate that can be transmitted over copper cables in structured cabling over a distance of 100 metres. At this

More information

[0.057] 5.8 [0.23]

[0.057] 5.8 [0.23] Product Specification 7 June 13 Rev B SL Series Jacks, Category 6 1. SCOPE 1.1 Content This specification covers performance, tests and quality requirements for AMP NETCONNECT*, Category 6 SL Jacks used

More information

ISO/IEC SC25 WG3. Who are they & what can they do for 802.3cg? Alan Flatman. Principal Consultant LAN Technologies.

ISO/IEC SC25 WG3. Who are they & what can they do for 802.3cg? Alan Flatman. Principal Consultant LAN Technologies. 1 ISO/IEC SC25 WG3 Who are they & what can they do for 802.3cg? Alan Flatman Principal Consultant LAN Technologies Email: a_flatman@tiscali.co.uk 2 Who are ISO/IEC SC25 WG3? Ø International systems group

More information

DC Center Copper Cabling up to 40Gbase-T. Halim Senjaya

DC Center Copper Cabling up to 40Gbase-T. Halim Senjaya DC Center Copper Cabling up to 40Gbase-T Halim Senjaya CTDC CTIA Data Center Expert Datwyler Singapore Diploma in Eng ng in Physics Bandung IT Diploma in Cloud DC Technologies - NP MBA Middlebury Institute

More information

ANSI/TIA-568-C Cat 6A Field Test Specifications

ANSI/TIA-568-C Cat 6A Field Test Specifications This document has been prepared to aid consultants or engineers in developing contractual specifications covering the certification of Category 6A Permanent Links. It is offered as a general guide. Suitability

More information

Design Guidelines. LANmark-6A Cabling System. January 2015 Revision 2.0. Nexans LANmark-6A Design Guidelines Ver January Page 1

Design Guidelines. LANmark-6A Cabling System. January 2015 Revision 2.0. Nexans LANmark-6A Design Guidelines Ver January Page 1 Design Guidelines LANmark-6A Cabling System January 2015 Revision 2.0 Nexans LANmark-6A Design Guidelines Ver 2.0 - January 2015 - Page 1 This document is intended to provide general guidance on LAN cabling

More information

The High Cost of a Low-Cost Cable Certification Tester

The High Cost of a Low-Cost Cable Certification Tester The High Cost of a Low-Cost Cable Certification Tester Our thanks to Fluke Networks for allowing us to reprint the following article. How much does it cost? That is typically the first question a cabling

More information

R&Mfreenet Advanced Cat 6 A Unshielded Connection Module

R&Mfreenet Advanced Cat 6 A Unshielded Connection Module R&Mfreenet Advanced R&Mfreenet Advanced Cat 6 A Connection Module The R&Mfreenet Cat 6 A unshielded connection modules, part of the Advanced cabling system, are ideal for voice, fast data transmissions

More information

Connectix Cabling Systems

Connectix Cabling Systems Connectix Cabling Systems Cabling Standards and CPR Update Jason Holroyd CNID Connectix CEP - Construction Products Director of regulations Business Development and the Impact on Cabling Standards CPD

More information

Power Over Ethernet with Panduit Copper Cabling. How To Create More Meaningful Connections With The Highest Performing Infrastructure

Power Over Ethernet with Panduit Copper Cabling. How To Create More Meaningful Connections With The Highest Performing Infrastructure Power Over Ethernet with Panduit Copper Cabling How To Create More Meaningful Connections With The Highest Performing Infrastructure Introduction Increasing usage of Power over Ethernet (PoE) represents

More information

AMP-TWIST* 6S Series SL Jack

AMP-TWIST* 6S Series SL Jack Product Specification 108-93003 16/Mar/2011 Rev E AMP-TWIST* 6S Series SL Jack 1. SCOPE 1.1 Content This specification covers performance, tests and quality requirements for AMP NETCONNECT*, AMP- TWIST*

More information

History Channel. 10G Ethernet on Copper

History Channel. 10G Ethernet on Copper 10G Ethernet on Copper History Channel Category Cable by Supported Technology Cat 1 - Telephone cable, ISDN Cat 3-10BaseT Cat 5-100BaseTX Cat 5e - 1000BaseT Cat 6-1000BaseT, but what about 10 Gigabit???

More information

PreCONNECT COPPER are factory assembled copper data cable Trunks and Multijumper for Plug-and-Play installations.

PreCONNECT COPPER are factory assembled copper data cable Trunks and Multijumper for Plug-and-Play installations. are factory assembled copper data cable Trunks and Multijumper for Plug-and-Play installations. Trunk 6 channels/stranded screened single cables S-STP Cat.7, AWG 23 installation cable diameter 22,3 mm

More information

Independent Testing - For End User Confidence

Independent Testing - For End User Confidence Independent Testing - For End User Confidence QUALIFICATION TESTING OF SCREENED CATEGORY 6 A ISO/IEC, CENELEC & TIA CONNECTING HARDWARE ACCORDING TO REQUIREMENTS OF EDITION 2.2 OF ISO/IEC 11801, CENELEC

More information

TIA TR-42 Liaison to IEEE

TIA TR-42 Liaison to IEEE TIA TR-42 Liaison to IEEE Val Rybinski Vice-Chair, TR-42.7 May 2005 Austin, TX Impact of PHY Capabilities Extended frequency characterization required Alien crosstalk limits and test methods required Strategies

More information

Hoist / Motor Controller Instruction Manual

Hoist / Motor Controller Instruction Manual Hoist / Motor Controller Instruction Manual Models: MCP4-DV-CEE, MCP4-DV-CEE16 MCP4-DV-CEENOLINK version 2.0 since 1 June 2017 DDL4 ATTENTION! This instruction manual contains important information about

More information

Open System Architecture Selecting the Right Cable and Connectivity for Your Application

Open System Architecture Selecting the Right Cable and Connectivity for Your Application Open System Architecture Selecting the Right Cable and Connectivity for Your Application Kenneth Cornelison Industry Consultant Wire and Cable Technology Engineering Resources Key Discussion Points TIA

More information

Connectix Cabling Systems

Connectix Cabling Systems Connectix Cabling Systems Cabling Standards and CPR Update Jason Holroyd CNID Connectix Director of Business Technology Development Day Welcome Agenda Introduction CPR and Standards update Lunch Residential

More information

ISO/IEC TR Guidance on 40GBASE-T T Cabling

ISO/IEC TR Guidance on 40GBASE-T T Cabling 1 ISO/IEC TR 11801-99 99-1 Guidance on 40GBASE-T T Cabling - a tutorial - Alan Flatman Principal Consultant LAN Technologies Email: a_flatman@tiscali.co.uk 2 Content 1. introduction to ISO/IEC SC25 WG3

More information

Contents. Structured Cabling Solutions. LAN Cables Patch Cords Connectors Patch Panels... 06

Contents. Structured Cabling Solutions. LAN Cables Patch Cords Connectors Patch Panels... 06 Contents Cat6 Structured Cabling Solutions U/UTP Cabling Solutions Structured Cabling Solutions LAN Cables... 03 Patch Cords... 04 Connectors... 05 Patch Panels... 06 U/FTP Cabling Solutions LAN Cables...

More information

NGEAB-T Use Cases. Berlin, Germany February Chris DiMinico MC Communications/Panduit

NGEAB-T Use Cases. Berlin, Germany February Chris DiMinico MC Communications/Panduit NGEAB-T Use Cases Berlin, Germany February 2015 Chris DiMinico MC Communications/Panduit cdiminico@ieee.org 1 Scope Next Generation Enterprise Access BASE-T PHY Study Group to define use cases and deployment

More information

Category 7A/7 Cabling Solutions P5 Voice & Outlets Product P24. Category 7A S/FTP Cable P6 Category 3 Indoor Multi Pair Cable P25

Category 7A/7 Cabling Solutions P5 Voice & Outlets Product P24. Category 7A S/FTP Cable P6 Category 3 Indoor Multi Pair Cable P25 COPPER SOLUTION Content Index Category 7A/7 Cabling Solutions P5 Voice & Outlets Product P24 Category 7A S/FTP Cable P6 Category 3 Indoor Multi Pair Cable P25 Category 7 S/FTP Cable P7 Category 3 Voice

More information

[0.057] 5.8 [0.23]

[0.057] 5.8 [0.23] Product Specification 7 March 13 Rev A1 SL Series Jacks, Category 6 1. SCOPE 1.1 Content This specification covers performance, tests and quality requirements for AMP NETCONNECT*, Category 6 SL Jacks used

More information

Mosaic TM LCS2 Cat. 6 RJ 45 socket

Mosaic TM LCS2 Cat. 6 RJ 45 socket 870 LIMOGES Cedex Telephone : + 33 0 5 55 06 87 87 - Fax: + 33 0 5 55 06 88 88 Mosaic TM LCS2 Cat. 6 Page 765 61 765 44 765 94 1. General characteristics...1 2. Presentation...2 3. Installation....2 4.

More information

complex network solutions

complex network solutions complex network solutions STRUCTURED CABLING CONTENT About Solarix Performance and Quality Key Features Market Share Why Solarix? Important Milestones Solarix Certificates CPR Solarix Product Labels Solarix

More information

Mosaic TM LCS2 Cat. 6 RJ 45 socket

Mosaic TM LCS2 Cat. 6 RJ 45 socket 870 LIMOGES Cedex Telephone : + 33 0 5 55 06 87 87 - Fax: + 33 0 5 55 06 88 88 Mosaic TM LCS2 Cat. 6 Page 765 61 765 44 765 94 1. General characteristics....1 2. Presentation...2 3. Installation...2 4.

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD ISO/IEC 11801-1 INTERNATIONAL STANDARD Edition 1.0 2017-11 Information technology Generic cabling for customer premises Part 1: General requirements INTERNATIONAL ELECTROTECHNICAL COMMISSION ICS 35.200

More information

Copper Cabling from 10G to 400G, and back down to 10Mbps, but on 1 pair only

Copper Cabling from 10G to 400G, and back down to 10Mbps, but on 1 pair only 1 Copper Cabling from 10G to 400G, and back down to 10Mbps, but on 1 pair only Gautier Humbert, RCDD Standards Coordinator Digital Infrastructures Legrand District Chair Mainland Europe BICSI 2 Agenda

More information

R&Mfreenet Advanced Cat 6A Shielded Connection Module

R&Mfreenet Advanced Cat 6A Shielded Connection Module R&Mfreenet Advanced R&Mfreenet Advanced Cat 6A Connection Module The R&Mfreenet Cat 6A shielded connection modules, part of the Advanced cabling system, are ideal for voice, fast data transmissions and

More information

Independent Testing - For End User Confidence

Independent Testing - For End User Confidence Independent Testing - For End User Confidence QUALIFICATION TESTING OF SCREENED CATEGORY 5 (CAT. 5e) CONNECTING HARDWARE ACCORDING TO REQUIREMENTS OF PROPOSED CENELEC 2nd EDITION EN 50173, PROPOSED ISO/IEC

More information

3M Category 6 Copper Structured Cabling System

3M Category 6 Copper Structured Cabling System Communication Markets Division 3M Category 6 Copper Structured Cabling System 3M RJ45 Category 6 Jacks UTP PL 3M Copper Patch Cords 3M Copper Patch Panels 3M Faceplates & Wall Outlets 3M Copper Cable 3M

More information

TECHNICAL DATA SHEET Family code C2424SOLPCORD CAT 6 UTP Solid. version 1 LSNH PATCHCORD date page 1/5

TECHNICAL DATA SHEET Family code C2424SOLPCORD CAT 6 UTP Solid. version 1 LSNH PATCHCORD date page 1/5 page 1/5 Application: High Density Switch & Hub Working area cord and telecommunications equipment cord in Local Area Networking environments Support current and future Category 6 applications, such as:

More information

HDMI Extender over Single CAT5/6 with 3DTV & Bi-Directional IR Support

HDMI Extender over Single CAT5/6 with 3DTV & Bi-Directional IR Support HDMI Extender over Single CAT5/6 with 3DTV & Bi-Directional IR Support Quick Installation Guide Introduction The HDMI Extender over Single CAT5/6 with 3DTV & Bi-Directional Support will extend HDMI 1.4

More information

Copper Cabling Standards

Copper Cabling Standards Copper Cabling Standards White paper White Paper Copper Cabling Standards v2.0 EN 1 Introduction Standard specifications are the foundation upon which most cabling and networking projects are built. Professionals

More information

Tarleton State University. Specifications

Tarleton State University. Specifications Tarleton State University Campus Communication Infrastructure Specifications Cabling Standards Summary This document identifies Tarleton State University communication infrastructure standards. The communication

More information

Cable into the Future: Industrial Ethernet with 10 Gbps

Cable into the Future: Industrial Ethernet with 10 Gbps Cable into the Future: Industrial Ethernet with 10 Gbps A White Paper presented by: Bernd Horrmeyer Industrial Network Cabling Specialist Phoenix Contact GmBH & Co. KG Blomberg, Germany Phoenix Contact

More information

C6Amodul and C6Amodul K. The connection system for a wide variety of applications of course with Cat.6A

C6Amodul and C6Amodul K. The connection system for a wide variety of applications of course with Cat.6A C6Amodul and C6Amodul K The connection system for a wide variety of applications of course with Cat.6A Intelligent system solution for structured cabling Nowadays the need for high data transfer rates

More information

FMT4S. High Density Connectivity Solution

FMT4S. High Density Connectivity Solution FMT4S High Density Connectivity Solution 2 FMT4S Solution Illustration FMT4S Optical Distribution Frame (ODF) FMT4S series is an advanced ODF series offering premium quality Data Center connectivity solution.

More information

Data sheet PM PCC OpDAT patch cord LC-D/LC-D OM3 aqua, 20.0 m

Data sheet PM PCC OpDAT patch cord LC-D/LC-D OM3 aqua, 20.0 m Illustrations Dimensional drawing Page 1/5 See enlarged drawings at the end of document Product specification patch cord for the METZ CONNECT Patch Management System multi mode patch cord I-V(ZN)H 50/125

More information

Jamey Calloway, RCDD Product Management Specialist Optical Cable Corporation

Jamey Calloway, RCDD Product Management Specialist Optical Cable Corporation Testing and deployment of direct attach and the impact of category 8 Thursday, 10 August 2017, 3:50-4:40 P.M. Jamey Calloway, RCDD Product Management Specialist Optical Cable Corporation Overview Traditional

More information

Updated Test Data for Channels based on Proposed Category 8.2 Connectivity IEC Augmented RJ45

Updated Test Data for Channels based on Proposed Category 8.2 Connectivity IEC Augmented RJ45 Updated Test Data for Channels based on Proposed Category 8.2 Connectivity IEC 61076-3-110 Augmented RJ45 Rich Marowsky, Bel Stewart Yakov Belopolsky, Bel Stewart IEEE P802.3bq 40GBASE-T Task force San

More information

Valena Life TM - Valena TM Cat. 6A RJ45 sockets

Valena Life TM - Valena TM Cat. 6A RJ45 sockets 128, av. du Maréchal-de-Lattre-de-Tassigny - 87045 LIMOGES Cedex Tel: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 www.legrand.com Valena Life TM - Valena TM 7 554 /21/22 1. USE Category 6A RJ45 socket.

More information

3M Telecommunications. Solutions for Networks. Volition 10G Copper Solutions. Innovation

3M Telecommunications. Solutions for Networks. Volition 10G Copper Solutions. Innovation 3M Telecommunications Solutions for Networks Volition 10G Copper Solutions Innovation Volition 10G Copper Solutions In less than 10 years, the speed of local area networks (LAN) has gone from less than

More information

Appendix 1 to the R&Mfreenet Warranty Program

Appendix 1 to the R&Mfreenet Warranty Program Appendix 1 to the R&Mfreenet Warranty Program 1 R&M Certification Process The R&Mfreenet certification process is three pillars: a) Adherence to applicable standards, both for products and installations;

More information

CABLING STRUCTURED Introduction and logic of structured cabling Wiring structure EXAMPLE OF THE STRUCTURE OF A WIRING SYSTEM

CABLING STRUCTURED Introduction and logic of structured cabling Wiring structure EXAMPLE OF THE STRUCTURE OF A WIRING SYSTEM 1 STRUCTURED CABLING 1.1 - Introduction and logic of structured cabling IT and Telecommunications are at the heart of all activities. They require structures capable of carrying various signals (telephony,

More information

Anticipating Cat 8 Agenda. Cat 8 Overview Cat 8 Customer Design Considerations Testing Procedures and Standards

Anticipating Cat 8 Agenda. Cat 8 Overview Cat 8 Customer Design Considerations Testing Procedures and Standards Anticipating Cat 8 Agenda Cat 8 Overview Cat 8 Customer Design Considerations Testing Procedures and Standards What is Cat 8? Next Generation Copper Cabling 25G and 40G data rates over twisted pair copper

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 INTERTEK TESTING SERVICES NA INC. 3933 U.S. Route 11 Cortland, NY 13045 Terence O Beirne Phone: 607 758 6316 www.intertek.com ELECTRICAL Valid To: March 31,

More information

Product information Patch Cord Cat. 5e, U/UTP, 4P, PVC, gray, RJ45/u- RJ45/u, 0.5 m

Product information Patch Cord Cat. 5e, U/UTP, 4P, PVC, gray, RJ45/u- RJ45/u, 0.5 m Product information Patch Cord, U/UTP, 4P, PVC, gray, RJ45/u- RJ45/u, 0.5 m R305014 101336005 10 Pcs. Cable identification: U/UTP Outer jacket: PVC Conductor diameter copper strand: AWG 26/7 Screened in

More information

Field-testing procedure of. LANmark-6 10G. Cabling System. Technical Paper Nexans Cabling Solutions June Revision 1.4

Field-testing procedure of. LANmark-6 10G. Cabling System. Technical Paper Nexans Cabling Solutions June Revision 1.4 Field-testing procedure of LANmark-6 10G Cabling System Technical Paper Nexans Cabling Solutions June 2007 - Revision 1.4 Table of Contents 1 Introduction 3 2 How to proceed? 4 2.1 Introduction 4 2.2 Permanent

More information

Physical Layer changes coming to a network near you, soon! Wayne Allen Regional Marketing Engineer Fluke Networks

Physical Layer changes coming to a network near you, soon! Wayne Allen Regional Marketing Engineer Fluke Networks Physical Layer changes coming to a network near you, soon! Wayne Allen Regional Marketing Engineer Fluke Networks Agenda New ISO/IEC 11801 Standard New Fibre standards and encoding methods Higher speeds,

More information

Product information 19" 3U Global Patch Panel 48xRJ45/u, Cat. 6, partly populated R302361

Product information 19 3U Global Patch Panel 48xRJ45/u, Cat. 6, partly populated R302361 Product information 19" 3U Global Patch Panel 48xRJ45/u, Cat. 6, partly populated R302361 1 Pcs. 19" 3U Global patch panel/u incl. cable tie shelf 12 connection module holders Global/u 3 Global blind covers

More information

STAR. Data Center High Density Connectivity Solution

STAR. Data Center High Density Connectivity Solution STAR Data Center High Density Connectivity Solution 2 STAR Solution Illustration Reach for the STAR: Data Center Connectivity that achieves new heights! Fibernet is proud to introduce the new STAR series,

More information

2x4 HDMI 1.3 CAT5e Distribution Amplifier

2x4 HDMI 1.3 CAT5e Distribution Amplifier 2x4 HDMI 1.3 CAT5e Distribution Amplifier Quick Installation Guide Introducing the 2x4 HDMI CAT5e Distribution Amplifier The 2x4 HDMI 1.3 CAT5e Distribution Amplifier provides the most flexible solution

More information

Test Report modcon - PS88A6M

Test Report modcon - PS88A6M modcon - PS886M Transmission Characteristics of PS886M /CT6 PS886M shielded CT6 plug fulfills the requirements for electrical transmission performance according to IEC 663-7-51; detail specification for

More information

NETWORK CONNECTIVITY SYSTEMS

NETWORK CONNECTIVITY SYSTEMS NETWORK CONNECTIVITY SYSTEMS Patch Cords/Testers JS-FTP Category 6A Patch Cords S-FTP Category 6 Patch Cords S-FTP Category 5E Patch Cords UTP Category 6 Patch Cords UTP Category 5E Patch Cords T-Adapters

More information

USB 3 Extenders. 4-Port Point-to-Point Extender System User Guide

USB 3 Extenders. 4-Port Point-to-Point Extender System User Guide USB 3 Extenders 4-Port Point-to-Point Extender System User Guide Document 411-0024-30 Rev A June 2018 Contents Introduction...3 Features...3 Unpacking...3 A Quick Look at the USB 3 Extenders...4 The Local

More information

LanTEK III FiberTEK III. Certifier for Copper and Fibre Cabling. Proof of Performance

LanTEK III FiberTEK III. Certifier for Copper and Fibre Cabling. Proof of Performance LanTEK III FiberTEK III Certifier for Copper and Fibre Cabling Proof of Performance LanTEK III FiberTEK III The LanTEK III is an easy to use cable certifier that meets existing TIA and ISO/IEC performance

More information

Enterprise Network Test Strategies for Network Availability and Performance. A Sitaramaiah Director Fluke Networks India

Enterprise Network Test Strategies for Network Availability and Performance. A Sitaramaiah Director Fluke Networks India Enterprise Network Test Strategies for Network Availability and Performance A Sitaramaiah Director Fluke Networks India 1 Why is Enterprise Network Testing becoming increasingly important? IT is increasingly

More information

AMP-TWIST* Modular Jack, UTP, Category 6A

AMP-TWIST* Modular Jack, UTP, Category 6A Product Specification 5 July 13 Rev A AMP-TWIST* Modular Jack, UTP, Category 6A 1. SCOPE 1.1 Content This specification covers performance, tests and quality requirements for TE Connectivity*, 6A UTP AMP-

More information

Category 8 paves the way for IEEE 40GBASE-T. David Hughes RCDD/DCDC/NTS Senior Technical Manager MEA CommScope

Category 8 paves the way for IEEE 40GBASE-T. David Hughes RCDD/DCDC/NTS Senior Technical Manager MEA CommScope Category 8 paves the way for IEEE 40GBASE-T David Hughes RCDD/DCDC/NTS Senior Technical Manager MEA CommScope Agenda Market need for 40 G over balanced twisted pair cabling Standards ISO/IEC 11801-99-1

More information

Link Segment IEEE Mb/s Single Twisted Pair Ethernet Study Group Chris DiMinico MC Communications/Panduit

Link Segment IEEE Mb/s Single Twisted Pair Ethernet Study Group Chris DiMinico MC Communications/Panduit Link Segment IEEE 802.3 10 Mb/s Single Twisted Pair Ethernet Study Group hris DiMinico M ommunications/panduit cdiminico@ieee.org 1 Purpose Scope Initiate discussion(s) on 10 Mb/s Single Twisted Pair Ethernet

More information

COMOSS FECON Series Media Converter Data Sheet. Overview

COMOSS FECON Series Media Converter Data Sheet. Overview IEEE 1394b Series Dongle COMOSS FECON Series Converter COMOSS FECON Series Media Converter Data Sheet Version 3.0 Layer 2, 100Base-FX for UTP to POF(Plastic Optical Fiber) Network Converter. Provides High-Speed

More information

Industry Standards in ICT Enabled Projects Reading and Applying the "Fine Print"

Industry Standards in ICT Enabled Projects Reading and Applying the Fine Print Industry Standards in ICT Enabled Projects Reading and Applying the "Fine Print" Gautier Humbert, RCDD Standards Coordinator Legrand Digital Infrastructures Gautier Humbert, RCDD BICSI District Chair Mainland

More information

LanTEK III FiberTEK III. Certifier for Copper and Fibre Cabling. Proof of Performance

LanTEK III FiberTEK III. Certifier for Copper and Fibre Cabling. Proof of Performance LanTEK III FiberTEK III Certifier for Copper and Fibre Cabling Proof of Performance LanTEK III FiberTEK III The LanTEK III is an easy to use cable certifier that meets existing TIA and ISO/IEC performance

More information

Structured. Copper cabling system CONNECTIVITY & CABLING SYSTEM

Structured. Copper cabling system CONNECTIVITY & CABLING SYSTEM Structured Copper cabling system CONNECTIVITY & CABLING SYSTEM Easy Crimp system p. 3 Patch cords and plugs p. 13 Work outlet p. 21 2 easy crimp Easy Crimp system 3 :top speed installation TIME SAVING

More information

BGP Support for Ipv6. Switch should have virtualization feature as one or more switch can act as a single Switch or equivalent IP clustering

BGP Support for Ipv6. Switch should have virtualization feature as one or more switch can act as a single Switch or equivalent IP clustering Minutes of the Pre-Bid Meeting - NATIONAL COMPETITIVE BIDDING FOR THE SUPPLY, Installation and Commissioning of LAN at 9 DH along with 2 ZH F.2 (499)/RHSDP/EPMC/HMIS/ NCB/4881 Dated 09.11.2010 Sl. Description

More information

Data sheet C6 A modul 1 port 180 M AP pure white

Data sheet C6 A modul 1 port 180 M AP pure white Illustrations Dimensional drawing Page 1/7 See enlarged drawings at the end of document Product specification surface-mount termination unit with C6modul 180 certified to GHMT Cat.6 re-embedded PVP component

More information

Telecommunication Cabling Standards to address IoT and power delivery. 5 October

Telecommunication Cabling Standards to address IoT and power delivery. 5 October Telecommunication Cabling Standards to address IoT and power delivery 1 5 October 2018 www.vti.net.au In a nut shell Out for comment NOW AS/NZS 11801.1 (General requirements) AS 11801.2 (Office) AS 11801.3

More information

Digital Remote for Hoist Controller Instruction Manual

Digital Remote for Hoist Controller Instruction Manual Digital Remote for Hoist Controller Instruction Manual Models: CMC-12D, CMC-8D, CMC-4D version 03.01 since 1 June 2017 ATTENTION! This instruction manual contains important information about the installation

More information

LANmark-6A. High-speed Copper Solution For 10 Gigabit Applications

LANmark-6A. High-speed Copper Solution For 10 Gigabit Applications LANmark-6A High-speed Copper Solution For 10 Gigabit Applications LANmark-6A High-Speed Copper Solution For 10 Gigabit Applications From the beginning on, 10G Ethernet was intended to retain backwards

More information

Guaranteed flexibility

Guaranteed flexibility LCS PATCH PANELS >>> equipped panels Guaranteed flexibility 327 23 327 09 With LCS mixed patch panels you can patch copper and optical fibre cables on the same panel These modular panels provide perfect

More information

OMEGA MODULAR PATCH PANEL EMPTY ENCLOSURE

OMEGA MODULAR PATCH PANEL EMPTY ENCLOSURE OMEGA MODULAR PATCH PANEL EMPTY ENCLOSURE The Omega MPP enclosure is based on a 19" frame, with 4 empty module slots for MPP modules. Highly flexible : any mix between twisted pair and optical fiber modules.

More information

LANmark-6 10G LANmark-6 A

LANmark-6 10G LANmark-6 A Field-testing procedure of LANmark-6 10G LANmark-6 A Cabling System Technical Paper Nexans Cabling Solutions March 2006 - Revision 1.1 Table of Contents 1 Introduction 3 2 How to proceed? 4 2.1 Introduction

More information

DATA SHEET. Catalyst Inline Power Patch Panel

DATA SHEET. Catalyst Inline Power Patch Panel DATA SHEET Inline Power Patch DEPLOYED IN THE WIRING CLOSET, THE CATALYST INLINE POWER PATCH PANEL PROVIDES FAST ETHERNET ENHANCEMENTS NEEDED FOR MULTISERVICE NETWORKING WHILE PRESERVING CUSTOMER INVESTMENTS

More information

Qualified Partner Programme QPP. Installation Practice Felice Guarna Wetzikon, July 2001

Qualified Partner Programme QPP. Installation Practice Felice Guarna Wetzikon, July 2001 Qualified Partner Programme QPP Installation Practice Felice Guarna Wetzikon, Why installation quality Product performance must be preserved by an accurate installation Long term warranty requires design

More information

LANmark-6A H I G H - S P E E D C O P P E R S O L U T I O N F O R 1 0 G I G A B I T A P P L I C A T I O N S

LANmark-6A H I G H - S P E E D C O P P E R S O L U T I O N F O R 1 0 G I G A B I T A P P L I C A T I O N S LANmark-6A H I G H - S P E E D C O P P E R S O L U T I O N F O R 1 0 G I G A B I T A P P L I C A T I O N S LANmark-6A High-Speed Copper Solution For 10 Gigabit Applications 10 Gigabit (10G) per second

More information

ÖLFLEX CLASSIC 130 H - halogen-free control cable, HFFR and flexible for various applications, U 0 /U: 300/500V

ÖLFLEX CLASSIC 130 H - halogen-free control cable, HFFR and flexible for various applications, U 0 /U: 300/500V PRODUCT INFORMATION Halogen-free control cable with improved fire characteristics - halogen-free control cable, HFFR and flexible for various applications, U 0 /U: 300/500V Info CPR: Article number choice

More information

3M Telecommunications. Solutions for Networks. 3M Volition. Class EA / Category 6A Cabling System

3M Telecommunications. Solutions for Networks. 3M Volition. Class EA / Category 6A Cabling System 3M Telecommunications Solutions for Networks 3M Volition Class EA / Category 6A Cabling System 3M Volition Class E A / Category 6A Cabling System In less than 10 years, the speed of local area networks

More information

CSRJ456K. White CSC624PP CSRJ456KB CSRJ456K90

CSRJ456K. White CSC624PP CSRJ456KB CSRJ456K90 PATCH PANELS & JACKS Cat6 Patch Panels Cat6 Keystone RJ45 Jack CSC616PP 16 CSRJ456K CSC624PP 24 CSRJ456KB CSC648PP 48 CSRJ456K90 90 Category 6 patch panel exceeds TIA/EIA-568-B.2-1 Category 6 & ISO 11801

More information

TN-5308 Quick Installation Guide

TN-5308 Quick Installation Guide TN-5308 Quick Installation Guide Moxa ToughNet Switch Edition 6.0, February 2017 Technical Support Contact Information www.moxa.com/support Moxa Americas: Toll-free: 1-888-669-2872 Tel: 1-714-528-6777

More information

Technical Committee. Addendum to ATM Physical Medium Dependent Interface Specification for 155 Mb/s Over Twisted Pair Cable (af-phy-0015.

Technical Committee. Addendum to ATM Physical Medium Dependent Interface Specification for 155 Mb/s Over Twisted Pair Cable (af-phy-0015. Technical Committee Addendum to ATM Physical Medium Dependent Interface Specification for 155 Mb/s Over Twisted Pair Cable (af-phy-0015.000) af-phy-0053.000 January 1996 af-phy-053.000 ATM Forum Technical

More information

Introduction. Standards

Introduction. Standards Introduction LAN cable certifiers have been the go-to method of testing twisted pair cabling for nearly a quarter century, since the advent of 10Base-T on Class C/category 3 cabling to 10 MHz. This article

More information

Common Mistakes Made in Certification Specifications and Testing. Jim Davis Regional Marketing Engineer Fluke Networks

Common Mistakes Made in Certification Specifications and Testing. Jim Davis Regional Marketing Engineer Fluke Networks Common Mistakes Made in Certification Specifications and Testing Jim Davis Regional Marketing Engineer Fluke Networks Common Mistake #1 Failing to specify a Permanent Link test #1 Permanent Link or Channel?

More information

PRODUCT INFORMATION. ETHERLINE Cat.5e FLEX. Info Industrial Ethernet cable Cat.5e Only for patch cable applications (max. 60 m)

PRODUCT INFORMATION. ETHERLINE Cat.5e FLEX. Info Industrial Ethernet cable Cat.5e Only for patch cable applications (max. 60 m) Ethernet cable Category 5e, Class D for flexible use - verified up to 100 MHz Industrial Ethernet cable Cat.5e for flexible use halogenfree or PUR (AWM-approval) outer sheath material, design 2 or 4 x2xawg26/7

More information