1 IBM Systems Lab Services and Training Measurement and Management Technologies (MMT) Data Center Solutions for a Smarter Planet
2 AGENDA IBM Energy Efficiency Program & Accomplishments IBM CO2 Reduction Commitment Featured Solution: Measurement and Management Technology 1.5 System 2 World Wildlife Fund Climate Savers Meeting
3 IBM s Commitment to Energy Efficiency IBM first established its Corporate Policy on Energy Conservation in 1974 Formalized energy conservation program continues unabated to this day IBM s Environmental Management System objectives include achieving and sustaining progress in improving the environment by maintaining a position of leadership in energy conservation; and reducing costs and increasing competitiveness and shareholder value through gains in energy efficiency. Achieving energy efficiency is one aspect of IBM s five-part strategy to reduce the company s operational greenhouse gas emissions IBM has a corporate goal to achieve annual energy conservation savings equal to 3.5% of IBM s total energy use IBM s experience in energy management and demonstrable results inform and contribute to the company s efforts in developing capabilities and solutions to bring value to its clients 3 World Wildlife Fund Climate Savers Meeting
4 IBM s Operational Energy Efficiency Performance Between 1990 and 2009, IBM saved 5.1 billion kilowatt-hours (kwh) of electricity consumption, avoided nearly 3.4 million metric tons of CO2 emissions (equal to 50 percent of the company s 1990 global CO2 emissions) and saved over $370 million through its annual energy conservation actions IBM s energy conservation goal recognizes only one year s MWH savings from identified projects that actually reduce or avoid the consumption of energy in its operations Reductions in energy consumption from downsizings, the sale of operations and cost avoidance actions are not included in the energy conservation performance In 2009, the energy IBM saved through over 1700 energy conservation projects was equivalent to 5.4 percent of its actual energy use. 246,000 megawatt-hours (MWH) of electricity; 410,000 million BTUs of fuel oil; nearly $27 million savings in energy costs Saving Focus Areas: Time of Day Scheduling and More Efficient Hardware for Lighting & HVAC Systems Building Recommissioning Efforts Data Center Thermal Management and Server Virtualization Projects Central Utility Plant and Building Control and Analytics Systems 4 World Wildlife Fund Climate Savers Meeting
5 IBM CO2 REDUCTION COMMITMENT CORPORATE GOAL: Between 1990 and 2005, IBM s energy conservation actions reduced or avoided CO2 emissions by an amount equal to 40 percent of its 1990 energy use. To further extend this achievement, IBM set itself an aggressive 2nd generation goal: to reduce the CO2 emissions associated with its energy use 12 percent by 2012 against a 2005 base year through energy conservation and the procurement of renewable energy IBM CLIMATE SAVERS GOAL: Corporate CO2 Reduction Goal Data Center Energy Efficiency Improvements: Thermal Management with MMT 1.0/1.5 (IBM Featured Solution) Server and Storage Virtualization Dynamic Cooling Data Center Design Innovations Today s Presentation will Focus on the Results of the MMT 1.5 Sloution 5 World Wildlife Fund Climate Savers Meeting
6 DATA CENTER ENERGY EFFICIENCY
7 DataCenter Energy Efficiency Opportunities FACILITIES Variable Cooling Delivery: Facilities System Improvements Liquid Heat Removal: Thermal Load Management Integrate Cooling Delivery with Equipment Demand Reduce System Power Losses Through Utilization of More Efficient Equipment Integration Maximizes Power Savings Air Flow Management Rack/Room Layout: Component Power Efficiency Optimize Delivery of Power and Cooling to The Data Center (Reduce Wastage) Power Management: Virtualization Product Design & Workload/Energy Management Rack Design Measure Adjust to Power & Workload Management: IT SYSTEMS Cap Workload Data Center Network 7 World Wildlife Fund Climate Savers Meeting
8 SOLUTION: MEASUREMENT & MANAGEMENT TECHNOLOGY 1.5
9 What is MMT? Data Center Measurement and Management Technologies Real-time and High resolution Measurements Measurement-based Modeling Management and Control High resolution measurements are made using IBM s Mobile Measurement Technology 9 World Wildlife Fund Climate Savers Meeting
10 Measurement and Management Technologies Measurement Survey and Analysis (MMT 1.0) 3D dimensional mapping tools for detailed environmental measurements Adapters to existing data sources (BMS, asset db) Dynamic Monitoring and Management (MMT 1.5) External and internal (via AEM, ITMfEM) Wired and wireless solutions Sensor grid solution with 1-wire protocol Access points every 2-4 for thermal, flow, pressure, and relative humidity (all with the same network) Acoustics, power, current and corrosion capabilities are being developed. MMT provides both high time & spatial resolution combining High resolution measurements / assessments for base model generation, sensor placement etc. Real-time sensing for feeding dynamic models 10 World Wildlife Fund Climate Savers Meeting
11 MMT 1.0 Measurement and Survey Analysis Solution Approach Three Steps 1 Measure 2 Analyze / Model Capture high resolution temperature data, air flow data and infrastructure & layout data To identify improvement opportunities model the data center and use optimization algorithms ( best practices rules ) 3 Implementation of Best Practices Realize air transport energy savings Realize thermodynamic energy savings Achieve reduced energy consumption Potential for deferring new investments 11 World Wildlife Fund Climate Savers Meeting
12 Savings Results From an MMT 1.0 Survey Surveyed 50,000 square feet of Raised Floor Space One-half million thermal, humidity and flow measurements 1000 rack inlet temperatures with ~ 5000 servers were measured measured air flow from all perforated tiles (total of >1600 flow measurements) inspected all 54 / 54 (active) ACUs* measured / estimated all relevant DC power levels Energy saving opportunities of up to 3.3 MW (~17% of IT) improve Air Conditioning Unit (ACU) utilization level from 59 % to 75 % (turn 14 ACUs off) higher ACU utilization reduced plenum temperature by 3 F reduce hotspots by 7 F in key areas using air flow management techniques increase chiller set point to increase chiller coefficient of performance leverage plate heat exchanger to bypass chiller and increase free cooling durations $0.06 / kwhour $0.14 / kwhour $0.09 / kwhour (actual) Germany and Denmark National Avg (estimated) (estimated) Annual potential energy reduction of 3.3 MWh $201,000 $468,000 $301,000 Potential 3 yr savings $603,000 $1,404,000 $903,000 Energy Savings/sf per year $3.94 $9.18 $5.90 Energy Savings/sf for 3 years $11.84 $27.54 $ month payback, 100% ROI on energy alone at $0.06 / kwhour 12 World Wildlife Fund Climate Savers Meeting
13 MMT 1.5 Dynamic Monitoring and Management Development of a real-time Measurement and Management Technology (MMT 1.5) Data centers are dynamic: MMT 1.0 is sparse in time but dense in space Real-time sensors are sparse in space but dense in time MMT 1.5 provides high time & spatial resolution 3D temperature distributions with cross-sections, inspections etc. alarm/threshold services efficiencies in real-time and corresponding cooling zones 13 World Wildlife Fund Climate Savers Meeting
14 Dynamic Monitoring and Management Process and Benefits Process for MMT 1.5 Set-up Use MMT 1.0 service to Identify Efficiency Improvements & Lay Out Sensor Network Install (real-time) sensor network (thermal, flow, humidity, pressure) Create MMT base model and divide Data Center into cooling zones Benefits: Monitor/compute local efficiency changes in real time with Dashboard & Weekly Reports Optimize Cooling Load as Equipment is Refreshed/Added or IT Power Varies Raise Overall Raised Floor Temperate to New ASHRAE Standard Reduce Cooling Reqs 14 World Wildlife Fund Climate Savers Meeting
15 Dynamic Monitoring and Management Installation Temp/humidity sensor Temp/flow sensor Tsense mounted on door Temp/pressure sensor Under floor cable mounted close to the raised floor Sensors 15 World Wildlife Fund Climate Savers Meeting End of row rack with sensor at 5.5 ft
16 IBM Corporate Environmental Affairs Measurement and Management Technologies Dynamic Monitoring and Management - Deployment Sensor access points are installed every ~ 2-4 feet (T-boxes) Install strategy allows maximum flexibility for sensors to be moved, removed and added Sensors are bar-coded and location / ID is tracked on MMT web client Thermal / humidity / pressure / flow sensors are supported on the same network Wired and wireless sensors are supported Sensor Hub Sensors T-box 16 World Wildlife Fund Climate Savers Meeting
17 Dynamic Monitoring and Management Grid Design Build-out area Hub T-Box Hub Ch 1 Hub Ch 2 Hub Ch 3 Hub Ch 4 Temperature Sensor Pressure Sensor Humidity Sensor Flow Sensor Existing area Background from AutoCAD Red = existing racks Blue = future racks 17 World Wildlife Fund Climate Savers Meeting
18 Dynamic Monitoring and Management - Cooling Zones ACU Info Zone boundaries Zone is 56% efficient Bar heights indicate efficiency of respective zones 18 World Wildlife Fund Climate Savers Meeting
19 Dynamic Monitoring and Management Active Data-Center Management (Client example A) Additional possible Energy Savings Possible capital Cost avoidance Realized Energy Savings Four types of Savings Energy Savings Delay of capital investments Increased reliability (cost avoidance) Lost revenue avoidance Customer Example: - DC power changes all the time - without active management, ACU utilization followed power density (blue curve) - customer started to use MMT 1.5 to actively manage ACUs to maintain constant 75% utilization level 19 World Wildlife Fund Climate Savers Meeting
20 Dynamic Monitoring and Management Hard Savings (Client example A) rapid ROI can be accomplished by active management to a prior ACU utilization level after ~ 30 weeks more than $1 / sqf of hard savings (@ $0.12 per kw hour ) another 20 % more energy savings are possible if managed to design point operation at 85 % of ACU utilization allows also increasing the power density from 77 to 93 W/sq ft, which can save an additional ~ $25 / sqf per year * in capital cost avoidance ~ $1000/sqf construction cost and 5% COC over 25 years 20 World Wildlife Fund Climate Savers Meeting
21 IBM Internal Deployment Measurement and Survey Analysis successfully deployed and implemented in more than 1M sq. ft. of internal DC space More than 20% cooling energy savings Almost 8M kwhour of savings today Over 25 IBM strategic data centers assessed Dynamic Monitoring and Management successfully deployed at large-scale production DC To actively manage large-scale dynamic DC Additional installations underway Wider rollout in NA and in EMEA Dynamic Monitoring and Management is part of the Raleigh NC Leadership Data Center design and architecture Full deployment in this new Leadership DC Integrated into ITD data models & asset management systems, Maximo and Tivoli 21 World Wildlife Fund Climate Savers Meeting
22 NEXT STEP: INTEGRATED MANAGEMENT OF DATA CENTER ASSETS AND SYSTEMS INVENTORY and TRACK IT ASSETS and LOCATIONS: Power Use Distribution Match Available Rack Space with Available Cooling Manage Equipment Refreshes DYNAMIC CONTROL OF COOLING DELIVERY Algorithms to Control Cooling Delivery Based on Sensor Data IT Equipment Power Management will Vary Power Load with Time Workload Management Based on Energy Use will enable Idling of Equipment at Low Workload Times. Integrate Data on Facilities and IT Equipment Track IT Equipment Power Use through Active Energy Manager (Equipment Based) OPTIMIZE DATA CENTER ENERGY USE ON A REAL TIME BASIS. 22 World Wildlife Fund Climate Savers Meeting
23 MMT integrated with Building Management System, IT to improve availability, capacity planning & energy management Alerting to business impacts IT and Facilities metrics and dashboards Optimal asset placement Optimize energy with thermal mapping IBM Tivoli Monitoring ITM for Energy Management, TBSM, Netcool Active Energy Manager, Director OSISoft PI IBM Asset Lifecycle Management Key data, facility requirements IBM MMT Thermal measurement, modelling, spatial planning IT Server data; Asset data DATA CENTER Room sensors; CRACs; PDUs BUILDING Siemens BMS; SquareD 23 World Wildlife Fund Climate Savers Meeting
24 IBM Corporate Environmental Affairs Measurement and Management Technologies MMT Variable Frequency Drive Control BEFORE: ACU Power Consumption = 11.5 kw Inlet Temperature Histogram # of occurances 100% % = cfm) MMT Sensor and control network max. Temp. Inlet temps [F] AFTER: ACU Power Consumption = 3.5 kw 84 % = cfm) # of occurances Inlet Temperature Histogram lower temps with less energy max. Temp. Variable capacity AC unit (ACU) Inlet temps [F] >2x reduction in (ACU) cooling power with no impact on inlet temperatures 51.1 F 24 World Wildlife Fund Climate Savers Meeting 93.2 F
25 Summary MMT Measurement and Survey Analysis can Deliver: Up to a 10% Reduction in IT power costs 10-20% Reduction in cooling power costs Opportunities Greatest at Data Centers that have not Managed Cooling (most) MMT Dynamic Monitoring and Management Offers Continuous Optimization Manage Cooling Through Equipment Refreshes and Changes in Data Center Operation Integrate Asset Data MMT Dynamic Monitoring and Management Can Match Heat Generation to the Thermal Load: Maximize Benefit of IT Equipment Power Management Capabilities. Functionality is being integrated into IBM s Software stack 25 World Wildlife Fund Climate Savers Meeting
26 Program Contacts Greg Mallare Opportunity Manager, Data Center Services Greg Harwick Manager, IBM Systems Lab Services and Training Data Center Services Or for more information contact us at: 26 World Wildlife Fund Climate Savers Meeting
27 Special notices IBM, the IBM logo, ibm.com, Let's Build A Smarter Planet, Smarter Planet and the planet icons are trademarks of International Business Machines Corporation, registered in many jurisdictions worldwide. Other product and service names might be trademarks of IBM or other companies. A current list of IBM trademarks is available on the Web at The results presented are illustrative only and not guarantees of future performance. Actual results may vary. 27 World Wildlife Fund Climate Savers Meeting
28 Dynamic Monitoring and Management - Benefits Maintain high saving rates Implement new ASHRAE guidelines Provides additional means to increase ACU utilization Currently average ACU utilization levels are still below 50% (2x over capacity) 1% improvement of ACU utilization can save 0.5 % of power Manages change in data center Equipment placement Dynamic cooling capacity to match cooling to IT power Provides unique visibility and control into the DC space Dashboard / summary views developed Global IBM Systems Lab Services and Training support & Tivoli Maximo SW support MMT 1.5 is an open/integrated system with ongoing IBM Research development 28 World Wildlife Fund Climate Savers Meeting
29 Dynamic Monitoring and Management - Architecture HOST data 29 World Wildlife Fund Climate Savers Meeting
30 Dynamic Monitoring and Management - Implementation Detailed ways to manage the data center using an MMT layout editor Real-time, 3D temperature, humidity, pressure distributions with cross-sections etc. Alarm / threshold services Efficiencies in real-time and corresponding cooling zones Reports and energy efficiency summaries Available in Maximo for Energy optimization (MEO) as a product and as a service 30 World Wildlife Fund Climate Savers Meeting
31 Dynamic Monitoring and Management - Alarms User-specified thresholds alarm alerts 31 World Wildlife Fund Climate Savers Meeting
32 Dynamic Monitoring and Management - Hard Savings (Client Example B) Modeled Average Inlet Temperature Estimated Energy Savings Modeled inlet temperature [F] baseline monitoring Hotspot mitigation work turn off ACUs and adjust settings increase of setpoints 12/8 1/19 3/2 4/13 date result monitoring Estimated Energy Savings [kwhour] weather - normalized turn off ACUs setpoint increase 1/5 21/1 1/5 2/9 3/16 4/20 date MMT provided energy savings without compromising inlet temperatures (reliability of IT equipment) hotspot mitigation was very effective driving down average inlet temperatures specific actions reduced significant hotspots locally - in one example, MMT alerted the client to adjust sub-optimum ACU settings, which had caused significant hotspots - the BMS did not detect problems with the ACU settings decommissioning of ACUs reduced inlet temperatures even more (low-utilized ACUs discharge warm air into the plenum) combination of turning off ACUs and hotspot mitigation allowed safely increasing set points 32 World Wildlife Fund Climate Savers Meeting
33 MMT Integration Active Energy Manager, ITMfEM, Maximo Delivering key energy management metrics through an integrated solution Centralized Energy Views Graphical view with key energy & thermal metrics Role-based energy dashboard Control & Power Management IBM Maximo Asset Manager for Energy Optimization IBM Tivoli Business Service Manager (optional) IBM Systems Director Active Energy Manager IBM Tivoli Monitoring for Energy Management Energy Reporting INFORMATION TECHNOLOGY FACILITIES & PROPERTY ASSETS 33 World Wildlife Fund Climate Savers Meeting
Measurement and Management Technologies (MMT) for more energy efficient Data Center and Telecommunication Facilities
Information and Communication Technology Portfolio Review San Francisco, CA March 2011 Project Name: Measurement and Management Technologies (MMT) for more energy efficient Data Center and Telecommunication
More informationInnovative Data Center Energy Efficiency Solutions
Innovative Data Center Energy Efficiency Solutions Dr. Hendrik F. Hamann IBM T.J. Watson Research Center 2/8/2009 2007 IBM Corporation A holistic Challenge: Energy & Thermal Management Energy / thermal
More informationCooling on Demand - scalable and smart cooling solutions. Marcus Edwards B.Sc.
Cooling on Demand - scalable and smart cooling solutions Marcus Edwards B.Sc. Schroff UK Limited Data Centre cooling what a waste of money! A 1MW data center needs 177,000,000 kwh in its lifetime of 10
More informationGreen IT and Green DC
Green IT and Green DC Alex SL Tay Regional Service Product Line Manager Site & Facilities Services, IBM ASEAN 1 What our clients are telling us We are running out of space in our data center We have environmental
More information18 th National Award for Excellence in Energy Management. July 27, 2017
18 th National Award for Excellence in Energy Management July 27, 2017 ICICI Bank, Data Centre, August Hyderabad 30 & 31, 2017 ICICI Bank - Revolution in Digital Banking Over 100,000 Digital POS in 4 months
More informationCRAH Retrofit and Energy Savings Project
CRAH Retrofit and Energy Savings Project Danny Johnson Director, Technical Operations Silicon Valley Leadership Group - Data Center Efficiency Summit October 24, 2012 2260 E. El Segundo Boulevard - A Digital
More informationCombining Cold Aisle Containment with Intelligent Control to Optimize Data Center Cooling Efficiency
A White Paper from the Experts in Business-Critical Continuity TM Combining Cold Aisle Containment with Intelligent Control to Optimize Data Center Cooling Efficiency Executive Summary Energy efficiency
More informationMSYS 4480 AC Systems Winter 2015
MSYS 4480 AC Systems Winter 2015 Module 12: DATA CENTERS By Satwinder Singh 14/05/2015 1 Data Centers Data Centers are specialized environments that safeguard your company's most valuable equipment and
More informationIBM Corporation. Global Energy Management System Implementation: Case Study. Global
Energy Management System Implementation: Case Study IBM Corporation ISO 50001 Registration: Results and Benefits It takes a global team to drive real success. Business case for energy management IBM is
More informationEnergy Performance Contracting
Energy Performance Contracting December 2017 Outlines Section One: Jonson Controls as an Energy Service Company (ESCO) Reasons behind investment in Energy Efficiency Section Two: Funding Options of Energy
More informationData Center Trends and Challenges
Data Center Trends and Challenges, IBM Fellow Chief Engineer - Data Center Energy Efficiency Customers challenges are driven by the following Increasing IT demand Continued cost pressure Responsive to
More informationFuture of Cooling High Density Equipment. Steve Madara Vice President and General Manager Liebert Precision Cooling Business Emerson Network Power
Future of Cooling High Density Equipment Steve Madara Vice President and General Manager Liebert Precision Cooling Business Emerson Network Power Agenda Issues facing the Data Center Managing the explosive
More informationSustainable Business with Green Datacenter
Site and Facilities Services Data Center Services Sustainable Business with Green Datacenter Prag, May 11th, 2010 Stephan Bhend, IBM Site and Facilities Services 2008 IBM Corporation Sustainable Business
More informationSmart Data Centres. Robert M Pe, Data Centre Consultant HP Services SEA
Smart Data Centres Robert M Pe, Data Centre Consultant Services SEA 2006 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice Content Data center
More informationDCIM Solutions to improve planning and reduce operational cost across IT & Facilities
DCIM Solutions to improve planning and reduce operational cost across IT & Facilities Presented by: Chi Sen, Director, Data Centre Software Solutions, APJ & EMEA Schneider Electric Data Center Solutions
More informationSystems and Technology Group. IBM Technology and Solutions Jan Janick IBM Vice President Modular Systems and Storage Development
Systems and Technology Group IBM Technology and Solutions Jan Janick IBM Vice President Modular Systems and Storage Development Power and cooling are complex issues There is no single fix. IBM is working
More informationAisleLok Modular Containment vs. Legacy Containment: A Comparative CFD Study of IT Inlet Temperatures and Fan Energy Savings
WHITE PAPER AisleLok Modular Containment vs. : A Comparative CFD Study of IT Inlet Temperatures and Fan Energy Savings By Bruce Long, Upsite Technologies, Inc. Lars Strong, P.E., Upsite Technologies, Inc.
More information84 kw, Tier 3, Direct Expansion, 937 ft 2
[Reference Design 42] 84 kw, Tier 3, Direct Expansion, 937 ft 2 DESIGN OVERVIEW Data Center IT Capacity 84 kw Target Availability Tier 3 Annualized PUE at 100% Load 1.712 Total Racks and Average Density
More informationEnergy Efficient Data Centers
IBM Systems and Technology Group Lab Services Energy Efficient Data Centers Steven Ahladas IBM Corp ahladas@us.ibm.com Keeping our clients in the race. All trends going the same way. IT Servers were an
More informationCurrent Data Center Design. James Monahan Sept 19 th 2006 IEEE San Francisco ComSoc
Current Data Center Design James Monahan Sept 19 th 2006 IEEE San Francisco ComSoc What is the biggest facility problem in your data center? 35% 30% 25% 20% 15% Series1 10% 5% 0% Excessive heat Insufficient
More informationRecapture Capacity for Existing. and Airflow Optimization
Recapture Capacity for Existing Data Centers Through Cooling and Airflow Optimization Introduction Challenges and Trends Agenda Cooling & Airflow Optimization Takeaways Learning Objectives Recognize opportunities
More informationMEASURE MONITOR UNDERSTAND
MEASURE MONITOR UNDERSTAND Presented by Alistair Hunt Energy Monitoring, Measurement metrics Where and What 1 History & Background Company Timeline 18 Years Comrac & Sinetica founded 15 Years Raritan Integration
More information3300 kw, Tier 3, Chilled Water, 70,000 ft 2
[Reference Design 22] 3300 kw, Tier 3, Chilled Water, 70,000 ft 2 DESIGN OVERVIEW Data Center IT Capacity 1100 kw per Data Hall 3 Independent Data Halls Design Application Range This design can be applied
More informationHPC Solutions in High Density Data Centers
Executive Report HPC Solutions in High Density Data Centers How CyrusOne s Houston West data center campus delivers the highest density solutions to customers With the ever-increasing demand on IT resources,
More information<Insert Picture Here> Austin Data Center 6Sigma DC CFD Model
Austin Data Center 6Sigma DC CFD Model Keith Ward Keith Ward Data Center Facilities Engineering and Logistics Design Austin Data Center Statistics - Space Original AT&T Designed and
More informationEfficiency of Data Center cooling
Efficiency of Data Center cooling Comparison of data room layouts and cooling systems Bohumil Cimbal Product manager for Cooling Systems in CONTEG Company Objective Basic questions between investor and
More informationRF Code Delivers Millions of Dollars in Annual Power & Cooling Savings for CenturyLink
INDUSTRIAL INTERNET IN ACTION CASE STUDY RF Code Delivers Millions of Dollars in Annual Power & Cooling Savings for CenturyLink CLIENT PROFILE CenturyLink Technology Solutions is the second largest telecommunications
More informationIBM Bromont Plant Technology for a Smarter Planet
IBM Plant Technology for a Smarter Planet McGill University February 23rd, 2011 Agenda IBM Canada IBM Smarter planet initiative IBM manufacturing plant Our continuous improvement journey MiQro Innovation
More informationOptimizing Cooling Performance Of a Data Center
ASHRAE www.ashrae.org. Used with permission from ASHRAE Journal. This article may not be copied nor distributed in either paper or digital form without ASHRAE s permission. For more information about ASHRAE,
More informationMission Critical Facilities & Technology Conference November 3, 2011 Cooling 101. Nick Gangemi Regional Sales Manager Data Aire
Mission Critical Facilities & Technology Conference November 3, 2011 Cooling 101 Nick Gangemi Regional Sales Manager Data Aire Agenda Exactly what are we talking about ASHRAE TC 9.9 Design best practices
More informationPower & Cooling Considerations for Virtualized Environments
Power & Cooling Considerations for Virtualized Environments Cisco Data Center Day 2008 31-01-2008 APC-MGE Vision & Mission OUR VISION APC-MGE products ensure availability wherever data is created, transmitted
More informationPROCESS & DATA CENTER COOLING. How and Why To Prepare For What s To Come JOHN MORRIS REGIONAL DIRECTOR OF SALES
PROCESS & DATA CENTER COOLING How and Why To Prepare For What s To Come JOHN MORRIS REGIONAL DIRECTOR OF SALES CONGRATULATIONS 2 BOLD PREDICTION 3 Where We Are TODAY Computer Technology NOW advances more
More informationNext Generation Cooling
Next Generation Cooling Server Manufacturer Perspective Practical and Cost Effective David Moss Data Center Strategist Dell 1 Why Chip, Row, or Rack? Density? Energy Don t be scared; I don t see 50kW/rack
More informationDATA CENTER COLOCATION BUILD VS. BUY
DATA CENTER COLOCATION BUILD VS. BUY Comparing the total cost of ownership of building your own data center vs. buying third-party colocation services Executive Summary As businesses grow, the need for
More informationFt Worth Data Center Power Metering for Real Time PUE Calculation. Scope of Work
Ft Worth Data Center Power Metering for Real Time PUE Calculation Scope of Work Prepared for the General Services Administration By Lawrence Berkeley National Laboratory Rod Mahdavi December 13, 2010 Executive
More informationsurvey, 71% of respondents listed Improving capacity planning as a top driver for buying DCIM 1.
:: In a recent Uptime Institute survey, 71% of respondents listed Improving capacity planning as a top driver for buying DCIM 1. 2 Maintain Assess Control ROI Monitor Optimize The Need for a Better Approach
More informationPartner Introduction
P R E S E N T S Partner Introduction September 16, 2013 Today s Agenda The Market Opportunity The Cooling Capacity Factor (CCF) New service Benefits to Upsite Partners How to Sell Launch Plan & Support
More informationEnergy Solutions for Buildings
Energy Solutions for Buildings Making energy safe, reliable, efficient, productive and green Make the most of your energy SM 1 Solutions to enable and sustain energy savings Technology is crucial to make
More informationPLAYBOOK. How Do You Plan to Grow? Evaluating Your Critical Infrastructure Can Help Uncover the Right Strategy
PLAYBOOK F O R C H A N G E How Do You Plan to Grow? Evaluating Your Critical Infrastructure Can Help Uncover the Right Strategy The world is becoming more digital every day. The demand for feature-rich,
More informationDCIM Data Center Infrastructure Management
DCIM Data Center Infrastructure Management Part 2 Implementation Challenges & Strategic Advantages - Predictive Analysis August 8, 2013 Presented by Julius Neudorfer Sponsored by Today s Topics Implementation
More informationRaytheon s Strategic IT Energy and Resource Management Program
Raytheon s Strategic IT Energy and Resource Management Program 2degrees Champion Award Application February 2015. Copyright 2014 Raytheon Company. All rights reserved. Customer Success Is Our Mission is
More informationEnvironmental & Efficiency Trends in Enterprise Computing. John Sheehy Systems Architect
Environmental & Efficiency Trends in Enterprise Computing John Sheehy Systems Architect jes@e-techservices.com Cost of Energy is Increasing But Inversely Correlated with US Dollar Without the 45-point
More informationPower Monitoring in the Data Centre
Power Monitoring in the Data Centre Fixed or Wireless Steve Strange RCDD ANIXTER INTERNATIONAL Agenda Energy Consumption Case Study Reasons to Monitor Power Monitoring Environmental Monitoring Asset Tags
More informationOptimize Your Data Center. Gary Hill VP, Business Development DVL Group, Inc.
Optimize Your Data Center Gary Hill VP, Business Development DVL Group, Inc. Data Center Age Profile Gartner Group Survey Legacy Data Centers Challenges Under Powered - Room or Racks Inadequate Air Delivery
More informationPassive RDHx as a Cost Effective Alternative to CRAH Air Cooling. Jeremiah Stikeleather Applications Engineer
Passive RDHx as a Cost Effective Alternative to CRAH Air Cooling Jeremiah Stikeleather Applications Engineer Passive RDHx as a Cost Effective Alternative to CRAH Air Cooling While CRAH cooling has been
More informationA Green Approach. Thermal
A Green Approach to Thermal Management Thermal Management - AGENDA Definitions & Thermal Facts Density Trends Rack Level Management Passive Solutions Thermal Sources & Green Solutions Data Center Layout
More informationMake the most of your Energy from Power Plant to Plug. Chris Simard, Regional Director Field Sales Group
Make the most of your Energy from Power Plant to Plug Chris Simard, Regional Director Field Sales Group We see six key challenges facing our world Connectivity Simplicity Globalization Demand For Energy
More informationLeveraging DCIM to Increase Energy Efficiency and Savings
August 6, 2013 Leveraging DCIM to Increase Energy Efficiency and Savings Siemens AG 2013 All rights reserved. usa.siemens.com/datacenters Contents Challenges of Today s Data Centers Turning Challenges
More informationGreen Data Centers A Guideline
Green Data Centers A Guideline Sekhar Kondepudi Ph.D Associate Professor Smart Buildings & Smart Cities Vice Chair Focus Group on Smart Sustainable Cities ITU-TRCSL Workshop on Greening the Future: Bridging
More informationImpact of Air Containment Systems
White Paper June 2012 WP-20 Impact of Air Containment Systems Reducing Energy Consumption Introduction: The Importance of Maintaining Data Center Cooling Energy Efficiency Data centers are mission-critical
More informationBENEFITS OF ASETEK LIQUID COOLING FOR DATA CENTERS
BENEFITS OF ASETEK LIQUID COOLING FOR DATA CENTERS Asetek has leveraged its expertise as the world-leading provider of efficient liquid cooling systems to create its RackCDU and ISAC direct-to-chip liquid
More informationEDX DC-3 environmental monitoring solution
EDX DC-3 environmental monitoring solution Designed to monitor and report on power, temperature and humidity conditions within a data centre, in real-time. Data Centre Power Consumption, Cooling Or Hot
More informationCreating an Energy-Efficient, Automated Monitoring System for Temperature and Humidity at a World-Class Data Center
About CyrusOne CyrusOne is a world-renowned enterprise data center provider that offers 40 data centers across the U.S., Europe and Asia with a three million-plus square feet of total net rentable space.
More informationCost Model Energy Benefits DirectAire & SmartAire Overview & Explanation
Cost Model Energy Benefits DirectAire & SmartAire Overview & Explanation A cost model (See figure 1) has been created to provide the user a simplified method for directly comparing the energy cost of a
More informationWhere s the Heat Coming From. Leland Sparks Global Account Technical Consultant Belden
Where s the Heat Coming From Leland Sparks Global Account Technical Consultant Belden What is the greatest DC challenge you face? Air Flow to Heat Load Relation Server Inlet Fans Chips Outlet LOAD Dell
More informationEP s approach to Power & Energy efficiency in DCs & paradigms
DG for Innovation and Technological Support EP s approach to Power & Energy efficiency in DCs & paradigms Presentation Presentation subtitle subtitle or lead-in or lead-in that says that what says what
More informationComputing in a Carbon Sensitive Environment
Computing in a Carbon Sensitive Environment Mick Walker Green Computing IBM Systems & Technology Group UKISA 2007 IBM Corporation Why should clients care? Is climate change happening and is human activity
More informationCritical Facilities Round Table SUN Microsystems Friday, March 25, Thursday, March 24, 2005 Wright Line LLC,
Critical Facilities Round Table SUN Microsystems Friday, March 25, 2005 Thursday, March 24, 2005 Wright Line LLC, 2003 1 Topic of Discussion Can standardization, non-uniform and high heat densities co-exist
More informationOptimization in Data Centres. Jayantha Siriwardana and Saman K. Halgamuge Department of Mechanical Engineering Melbourne School of Engineering
Optimization in Data Centres Jayantha Siriwardana and Saman K. Halgamuge Department of Mechanical Engineering Melbourne School of Engineering Outline Background and Motivation Overview and scale of data
More informationSIX Trends in our World
Data Center Infrastructure for Cloud and Energy Efficiency SIX Trends in our World Connectivity Simplicity StruxureWare TM for data centers TuanAnh Nguyen, Solution Engineer Manager, Vietnam Schneider
More informationCIO Forum Maximize the value of IT in today s economy
CIO Forum Maximize the value of IT in today s economy Laura Scott, Vice President Service Product Line Sales Global Technology Services IT infrastructure is reaching a breaking point. 85% idle In distributed
More informationReclaim Wasted Cooling Capacity Now Updated with CFD Models to Support ASHRAE Case Study Data
White Paper EC9005A Reclaim Wasted Cooling Capacity Now Updated with CFD Models to Support ASHRAE Case Study Data Peer reviewed case study data from ASHRAE now updated with CFD model analysis revealing
More informationwhere we are, where we could be, how we can get there. 12/14/2011
Central Plant Optimization ASHRAE National Capitol Chapter - PES Wednesday, Nov 7, 2011 Dave Klee, LEED AP Director, Optimized Building Solutions Johnson Controls, Inc. 1 1 J o http://www.johnsoncontrols.com/cpo
More informationBuilding Management Solutions. for Data Centers and Mission Critical Facilities
Building Management Solutions for Data Centers and Mission Critical Facilities How Efficient is Your Data Center? Recent years have seen rapid growth in global demand for computing capacity, resulting
More informationData Center Infrastructure Management (D.C.I.M.)
Data Center Infrastructure Management (D.C.I.M.) Garies Chong, RCDD, DCDC. BICSI Southeast Asia District Chair Managing Director of EMS Wiring Systems Pte Ltd Data Center Infrastructure Management (D.C.I.M.)
More informationHP environmental messaging
HP environmental messaging Promise Definition Designing for the environment As a technology industry environmental leader for decades, HP is making a difference with a comprehensive Design for the Environment
More informationGoogle s Green Data Centers: Network POP Case Study
Google s Green Data Centers: Network POP Case Study Table of Contents Introduction... 2 Best practices: Measuring. performance, optimizing air flow,. and turning up the thermostat... 2...Best Practice
More informationCommitted to Energy Efficiency
RESOLUTE Resolute Helps PNC Arena Reduce Energy Consumption and Costs While Improving Fan Comfort Lacking the visibility, real-time data and analytics needed to optimize facility performance and reduce
More informationCisco Lab Setpoint Increase. Energy Efficient Data Center Demonstration Project
Cisco Lab Setpoint Increase Energy Efficient Data Center Demonstration Project About the Energy Efficient Data Center Demonstration Project The project s goal is to identify key technology, policy and
More informationHow High Temperature Data Centers & Intel Technologies save Energy, Money, Water and Greenhouse Gas Emissions
Intel Intelligent Power Management Intel How High Temperature Data Centers & Intel Technologies save Energy, Money, Water and Greenhouse Gas Emissions Power savings through the use of Intel s intelligent
More informationPredictive Resilience: Leveraging Integrated DCIM to Reduce Data Center Downtime
July 17, 2013 Predictive Resilience: Leveraging Integrated DCIM to Reduce Data Center Downtime siemens.com/answers Predictive Resilience Table of content What is DCIM & Its Business Value Extract Maximum
More informationCatch the Heat Avoid the Heat! How an integrated management approach helps to operate your data center energy efficient and reliable
Catch the Heat Avoid the Heat! How an integrated management approach helps to operate your data center energy efficient and reliable Urs Iten, Director Global Portfolio Management Data Center siemens.com/datacenters
More informationData Center Energy and Cost Saving Evaluation
Available online at www.sciencedirect.com ScienceDirect Energy Procedia 75 (2015 ) 1255 1260 The 7 th International Conference on Applied Energy ICAE2015 Data Center Energy and Cost Saving Evaluation Z.
More informationAbout Schneider Electric
About Schneider Electric Global Company $30 billion USD revenue in 2013 41% of sales in new economies 150,000+ people in 100+ countries 175 year history World Class Brands Built or Acquired Strong US Presence
More informationIT optimization White paper May Optimize energy use for the data center through enhanced measurement and management
IT optimization White paper May 2008 Optimize energy use for the data center through enhanced measurement and management Table of Contents 3 Overview Recognize the critical need for energy-efficient data
More information1.0 Executive Summary. 2.0 Available Features & Benefits
Statement Of Work Energy Management Services Table of Contents 1.0 Executive Summary 2.0 Available Features & Benefits 3.0 Assessment Deliverables Selection 4.0 On Site Assessment Activities 5.0 Exclusions
More informationDC Energy, Efficiency Challenges
DC Energy, Efficiency Challenges Choosing a density strategy Implementing a high density environment Maximizing the efficiency benefit Anticipating the dynamic data center Key points on energy usage in
More informationPower and Cooling for Ultra-High Density Racks and Blade Servers
Power and Cooling for Ultra-High Density Racks and Blade Servers APC White Paper #46 Richard L. Sawyer Director of Data Center Technology American Power Conversion Company 2005 APC corporation What has
More information2000 kw, Tier 3, Chilled Water, Prefabricated, sq. ft.
[Reference Design 64] 2000 kw, Tier 3, Chilled Water, refabricated, 23700 sq. ft. DESIGN OVERVIEW Data Center IT Capacity 2000 kw Target Availability Tier 3 Annualized E at 100% Load 1.64 in Miami, FL
More informationLet s Build a Smarter Planet:
Derek FU IBM Service Management Solution Architect JUL/09/2010 Let s Build a Smarter Planet: Smarter Buildings from the Earth up A globally integrated world creates new interwoven issues. On going pressures
More informationCooling Solutions & Considerations for High Performance Computers
Cooling Solutions & Considerations for High Performance Computers White Paper 6 Revision 1 By Rich Whitmore Executive summary The recent advances in high performance computing have driven innovations not
More informationData Center Lifecycle and Energy Efficiency
Data Center Lifecycle and Energy Efficiency Lifecycle infrastructure management, power management, thermal management, and simulation solutions enable data center modernization. White Paper October 2014
More informationData Center Infrastructure Management (DCIM) Demystified
software is quickly becoming the core engine of data center operations. Only 5 years ago, manual spreadsheets, sometimes supplemented with Visio diagrams, were accepted as the default tools for data center
More informationData Center Infrastructure Management (DCIM) By Jesse Zhuo
Data Center Infrastructure Management (DCIM) By Jesse Zhuo Agenda The Evolution of DCIM Users Perspectives Management Methodology by Delta DCIM The Evolution of DCIM What is DCIM DCIM is software for Data
More informationEnergy Efficiency Solutions for Your Data Center
Energy Efficiency Solutions for Your Data Center Chapter One: Cooling Assessments Click a section below You Know You Need a Cooling Assessment When Cooling Assessments Yield Benefits Now and in the Future
More informationFundamentals of CFD and Data Center Cooling Amir Radmehr, Ph.D. Innovative Research, Inc.
Minneapolis Symposium September 30 th, 2015 Fundamentals of CFD and Data Center Cooling Amir Radmehr, Ph.D. Innovative Research, Inc. radmehr@inres.com Learning Objectives 1. Gain familiarity with Computational
More informationApplication of TileFlow to Improve Cooling in a Data Center
Case Study Application of TileFlow to Improve Cooling in a Data Center 3025 Harbor Lane North, Suite 300 Plymouth, MN 55447 USA Copyright 2004 Innovative Research, Inc. 2 Introduction A large insurance
More informationSustainable IT at Stanford
Sustainable IT at Stanford Strategic Plan: 2012 2014 Overview As Stanford has continued to pursue its commitment to environmental stewardship, Stanford s Sustainable IT program has continued to deliver
More informationNovember/December 2011
November/December 2011 Company is justifiably proud of its new facilities Helping companies plan, design, operate, and eventually refresh or repurpose their data centers more efficiently and effectively
More informationECOBAY: Closed loop water cooled server cabinet for data centers
ECOBAY: Closed loop water cooled server cabinet for data centers ELECTRONICS MANUFACTURING SERVICES Communications Computing Multimedia & Consumer Industrial & Semiconductor Defense & Aerospace Medical
More informationFOM 2.4 The Performance Indicator: Assessing & Visualizing Data Center Cooling Performance
FOM 2.4 The Performance Indicator: Assessing & Visualizing Data Center Cooling Performance Mark Seymour AFCOM DCW 12th Sept. 2016 Future Facilities - speaking on behalf of The Green Grid 1 The Green Grid
More informationCA ecometer. Overview. Benefits. agility made possible. Improve data center uptime and availability through better energy management
PRODUCT SHEET: CA ecometer CA ecometer Improve data center uptime and availability through better energy management agility made possible CA ecometer helps you to visualize, monitor, and better manage
More informationHot vs Cold Energy Efficient Data Centers. - SVLG Data Center Center Efficiency Summit
Hot vs Cold Energy Efficient Data Centers - SVLG Data Center Center Efficiency Summit KC Mares November 2014 The Great Debate about Hardware Inlet Temperature Feb 2003: RMI report on high-performance data
More informationDATA CENTER EFFICIENCY: Data Center Temperature Set-point Impact on Cooling Efficiency
DATA CENTER EFFICIENCY: Data Center Temperature Set-point Impact on Cooling Efficiency September 27 th, 2013 Tejas Desai, PE CEM CEA LEED AP Sameer Behere, PE CEM LEED AP Agenda Problem: Quick fixes can
More informationComprehensive Data Center Energy Management Solutions
FROM INSIGHT TO EFFICIENCY: Comprehensive Data Center Energy Management Solutions Since 1995, facility managers and BAS professionals have relied on the Niagara framework to provide full convergence of
More informationEnergy Action Plan 2015
Energy Action Plan 2015 Purpose: In support of the Texas A&M University Vision 2020: Creating a Culture of Excellence and Action 2015: Education First Strategic Plan, the Energy Action Plan (EAP) 2015
More informationData Centre Energy Efficiency. Duncan Clubb EMEA Data Centre Practice Director CS Technology
Data Centre Energy Efficiency Duncan Clubb EMEA Data Centre Practice Director CS Technology Key Messages No more silos energy efficiency only comes from a holistic approach to DC design and operation If
More informationChecklist for building an edge data center
Checklist for building an edge data center Building an edge data center to provide a cloud computing environment within a service provider central office can be a complex endeavor. It requires lots of
More informationHow Liquid Cooling Helped Two University Data Centers Achieve Cooling Efficiency Goals. Michael Gagnon Coolcentric October
How Liquid Cooling Helped Two University Data Centers Achieve Cooling Efficiency Goals Michael Gagnon Coolcentric October 13 2011 Data Center Trends Energy consumption in the Data Center (DC) 2006-61 billion
More informationFederal Data Center Consolidation Initiative (FDCCI) Workshop III: Final Data Center Consolidation Plan
Federal Data Center Consolidation Initiative (FDCCI) Workshop III: Final Data Center Consolidation Plan August 10, 2010 FDCCI Agenda August 10 th, 2010 1. Welcome Katie Lewin GSA Director Cloud Computing
More information