Energy Efficient Data Centers
|
|
- John Sharp
- 5 years ago
- Views:
Transcription
1 IBM Systems and Technology Group Lab Services Energy Efficient Data Centers Steven Ahladas IBM Corp Keeping our clients in the race.
2 All trends going the same way. IT Servers were an asset, tend to be a commodity Energy was a commodity for servers, tend to be a cost But.. Data Centers energy cost now shows Appear as a critical limitation to server extension in the data center Heat increase can be a growth killer by stopping introduction of new servers (DataCenter rooms limitations) Energy economics around IT servers must be rebalanced with new energyconscious criteria to stop cost increase 1) Stop the trend 2) Reduce power consumption Spending (US$B) $120 $100 $80 $60 $40 $20 $0 New Server Spending Power and Cooling IDC Presentation, The Impact of Power and Cooling on Data Center Infrastructure, Doc #201722, May 2006 Installed Base (M Units) Keeping our clients in the race.
3 Energy/Performance Metrics Server performance increasing much faster than server power Server/Storage Performance/Energy Trends 80 High End z xseries 1U p550 High End Storage 70 Annual Change(%) Perf(capacity for storage) Power Perf/Space Perf/Watt Source: Roger Schmidt 3 Keeping our clients in the race.
4 Comparison of typical server utilization rates Used Wasted Mainframe UNIX x86 4 Keeping our clients in the race.
5 Energy Management Policy Example Server Consolidation Conserves Energy APP 1 APP 2 APP 3 APP 4 8 APP 7 APP APP 8 APP 1 APP 2 APP 3 APP 4 APP 5 APP 6 APP 7 System 1 System 2 System 8 Advanced Virtualization 10% busy 1KW 10% busy 1KW 10% busy 1KW 70% busy 4KW Total Power 8KW Total Power 4KW Server consolidation exploiting virtualization is the most effective tool in reducing energy costs 5 Keeping our clients in the race.
6 Cool Blue: Virtualization on IBM Systems and Storage This shift has eliminated one floor of servers, cut power and cooling costs by 80 percent, and reduced the administrative staff (and costs) by 10 administrators. No other platform has clearly demonstrated the vertical scaling (scale-up) savings as the mainframe. Virtualization was first introduced by IBM in the 1960s to allow the partitioning of large mainframe environments. System z virtualization remains the gold standard today. IBM SAN Volume Controller (SVC). for storage virtualization increases storage utilization rates by 30% while reducing the growth rate of storage capacity by 20%. VMware, Microsoft Virtual Server and Xen offerings are available for IBM System x and IBM BladeCenter Dell PowerEdge 1950 Dell PowerEdge 1950 virtualized Dell PowerEdge 1955 Dell PowerEdge 1955 virtualized IBM System z BC S07 Small IBM System z BC S07 Expanded Annual Power Cost per Logical Server 0 $100 $200 $300 $400 $500 $600 $700 $800 $900 $1,000 $ $ $ $ $ $73.06 IBM System z EC S18 $ Keeping our clients in the race. Source: Avoiding the $25 Million Server Data Center Power, Cooling, and Growth report by Sine Nomine Associates, 4/6/07
7 Cool Blue: Storage virtualization Pool and share I/O Resources for: Improved utilization Reduced energy needs Combined utilization 50% IBM SAN Volume Controller EMC IBM HP Hitachi IBM Combined utilization 90% 7 Keeping our clients in the race.
8 Cool Blue: Deploy efficient IBM System Storage 10 year TCO example using blended tape and disk best practices Deploy more power efficient storage Utilize storage more efficiently 250TB of storage 25% growth over 10 years 8 Keeping our clients in the race.
9 Reduce Consumption Through Provisioning De-provision Standby Servers Active Servers Standby Servers Provisioned 875 Servers De-provisioned 125 Servers Power Savings In Standby Mode 9 Keeping our clients in the race.
10 Energy Efficient Data Centers Data Center Power Usage Effectiveness % Number of Data Centers % 60.00% 40.00% 20.00% More Building / IT Eqt Power 0.00% 10 Keeping our clients in the race.
11 DATA CENTER ENERGY EFFICIENCIES Total Power = 580 kw DATA CENTER A UPS Losses 6% DATA CENTER B Computer Loads 63% Total Power = 1700 kw Computer Loads 38% HVAC 54% UPS Losses 13% Lighting 2% Lighting 1% HVAC - Chilled Water Plant 14% HVAC - Air Movement 9% Data Center A: 54 % HVAC ; Data Center B: 23 % HVAC Data Center A could possibly save ~ 180 kw Those that did many things well still had room to improve From LBNL DC energy study, W. Tschudi 11 Keeping our clients in the race.
12 TYPICAL RAISED FLOOR DATA CENTERS GOAL: provide specified inlet temperatures to every IT Rack as efficiently as possible 12 Keeping our clients in the race.
13 3D Temperature distributions of IBM supercomputer o C cold aisle hot aisle z=2.5 z=3.5 z=4.5 z=5.5 z=6.5 z=8.5 z=0.5 z=7.5 z=1.5 feet Hot spot at long aisle o C z o C y x Measured 3D temperature maps of a datacenter 13 Keeping our clients in the race.
14 Verticle Temperature Gradients 45 inlet air temperature T inlet [ o C] upper specs height [feet] 14 Keeping our clients in the race.
15 COOLING EFFICIENCY #1: INTERMIXING between hot and cold air increases locally Inlet Air Temperatures ( excessive low CRAC discharge temperatures; affects Cooling Production Efficiency) #2: RECIRCULATION causes small differences in Return and CRAC Discharge Temperatures ( CRAC units are not fully utilized; affects Cooling Delivery Efficiency) 15 Keeping our clients in the race.
16 PERFORATED TILES 56% open, no damper 56% open, with damper - in many places perf. tiles do not support for the required cooling capacity - get high throughput tiles (50 % open) - remove dampers to enhance air flow (300 cfm ~ 2 kw) Tate GrateAire 56% Tate GrateAire 56% w/ 100% Open Damper Static Pressure, in H2O Airflow, CFM 16 Keeping our clients in the race.
17 UNDER-FLOOR BLOCKAGE Examples for blockage cables water pipes - avoid any blockage in the critical path to perforated tiles - put cabling etc. under hot aisles - possibly deploy under-floor boundaries - limit underfloor airflow to the boundaries of the zone to be cooled - escaping air results in lower underfloor air pressure and room airflow - use under-floor barriers to limit the airflow to the needed places 17 Keeping our clients in the race.
18 LEAKS AND CABLE CUTOUTS - block cable cut-outs using the methods shown below - add perforated tiles & use higher throughput tiles - try to have good sealing between the tiles Brushes Bags Mats Pillows 18 Keeping our clients in the race.
19 LEAKAGE in Sample Raised Floors # CRACs total flow/cooling capacity 1 # perf. tiles total perf. tile flow/cooling capacity 1 total ceiling tile flow/cooling capacity 1 Not-targeted flow/cooling 2 Total HW / Room Power Margin # cfm 450 kw cfm 200 kw 1900 cfm 12 kw cfm 250 kw 300/360 kw 87/104 tons 90 kw 26 tons 130 tons 58 tons 3 tons 72 tons (57 %) (25 %) # cfm 285 kw cfm 73 kw 2000 cfm 13 kw cfm 211 kw 110/140 kw 32/41 tons 145 kw 42 tons 82 tons 21 tons 4 tons 61 tons (74 %) (103 %) # cfm 560 kw cfm 40 kw NA cfm 520 kw 175/230 kw 51/68 tons 330 kw 96 tons 162 tons 12 tons 151 tons (93 %) (143 %) # kcfm 1294 kw kcfm NA kcfm 310 kw 918 kw 585/730 kw 170/212 tons 564 kw 164 tons 375 tons 90 tons 266 tons (71 %) (77%) 60F (16 o C) CRAC discharge temperature 2.) Cable cutouts, other losses H.Hamman 2/ Keeping our clients in the race.
20 Normal Operation of Server Understanding Where Costs Hide is Critical Rear Door Heat exchanger can remove over 50% of a rack s s heat output Front Cold Air flow Back Hot No new fans or electricity needed. Attaches to back of rack (adds 5 ) No rearrangement of datacenter Cost effective; 1KW cooling = $286 Perf tile Cable Opening Tile floor Underfloor Chilled Air Subfloor Improved Operation of Server Rear Door Heat Xchanger The Cool Blue Heat exchanger adds cooling capacity at ~1/4 the cost of traditional methods Air flow Front Cold Back Hot IBM Enterprise Rack Rear Door Heat Exchange water lines 20 Keeping our clients in the race. Perf tile Cable Opening Underfloor Chilled Air Tile floor Subfloor
21 Motivation for Liquid Cooling - Increase in heat removal performance: Superior thermal properties of liquids compared to air - Design flexibility: Sensible heat transport to locations with available space - Centralized secondary heat exchanger - Efficient water-water heat exchanger Thermal conductivity [W/(m*K)] Air H 2 O Volumetric heat capacity [kj/(m 3 *K)] Disadvantage: Increased complexity Secondary Transport Primary Long distance transport possible 21 Keeping our clients in the race. Limited heat transport due to fin efficiency
22 Data Center Power Distribution Systems & Efficiency Requires this much power at the facility level Power Conversion & Distribution Losses One Watt Of Chip Power Feeder Transformer UPS System Raised Floor Transformer Distribution (all combined) Server Bulk PS VRM Load - Std Raised Floor 480V Servers 11.2KV(AC) to 480VAC 11.2KV(AC) to 480VAC 5% 480VAC to 400VDC to 480VAC 480VAC to 400VDC to 480VAC 480VAC to 208VAC to - 208VAC 400VDC to 12VDC NA - 480VAC to 400VDC to 12VDC 12VDC to 1VDC Std Watts VDC to 1VDC 480V Watts VDC to heat 1VDC to heat 400V DC Servers 400V DC Watts 11.2KV(AC) to 480VAC 12% 480VAC to 400VDC NA - 400VDC to 12VDC 12VDC to 1VDC VDC to heat Capital/Cost of Acquisition Savings 22 Keeping our clients in the race.
23 Thank You! Questions? Steve Ahladas, Data Center Services: 23 Keeping our clients in the race.
Green IT and Green DC
Green IT and Green DC Alex SL Tay Regional Service Product Line Manager Site & Facilities Services, IBM ASEAN 1 What our clients are telling us We are running out of space in our data center We have environmental
More informationFuture of Cooling High Density Equipment. Steve Madara Vice President and General Manager Liebert Precision Cooling Business Emerson Network Power
Future of Cooling High Density Equipment Steve Madara Vice President and General Manager Liebert Precision Cooling Business Emerson Network Power Agenda Issues facing the Data Center Managing the explosive
More informationMoving Containment Inside the Enclosure. Jeff Markle Great Lakes Case & Cabinet
Moving Containment Inside the Enclosure Presented by Jeff Markle Great Lakes Case & Cabinet Containment Containment : To put constraint upon; to restrain; to confine; to keep within bounds Containment
More informationFundamentals of CFD and Data Center Cooling Amir Radmehr, Ph.D. Innovative Research, Inc.
Minneapolis Symposium September 30 th, 2015 Fundamentals of CFD and Data Center Cooling Amir Radmehr, Ph.D. Innovative Research, Inc. radmehr@inres.com Learning Objectives 1. Gain familiarity with Computational
More informationRecapture Capacity for Existing. and Airflow Optimization
Recapture Capacity for Existing Data Centers Through Cooling and Airflow Optimization Introduction Challenges and Trends Agenda Cooling & Airflow Optimization Takeaways Learning Objectives Recognize opportunities
More informationMission Critical Facilities & Technology Conference November 3, 2011 Cooling 101. Nick Gangemi Regional Sales Manager Data Aire
Mission Critical Facilities & Technology Conference November 3, 2011 Cooling 101 Nick Gangemi Regional Sales Manager Data Aire Agenda Exactly what are we talking about ASHRAE TC 9.9 Design best practices
More informationCooling on Demand - scalable and smart cooling solutions. Marcus Edwards B.Sc.
Cooling on Demand - scalable and smart cooling solutions Marcus Edwards B.Sc. Schroff UK Limited Data Centre cooling what a waste of money! A 1MW data center needs 177,000,000 kwh in its lifetime of 10
More informationOptimization in Data Centres. Jayantha Siriwardana and Saman K. Halgamuge Department of Mechanical Engineering Melbourne School of Engineering
Optimization in Data Centres Jayantha Siriwardana and Saman K. Halgamuge Department of Mechanical Engineering Melbourne School of Engineering Outline Background and Motivation Overview and scale of data
More informationOptimizing Cooling Performance Of a Data Center
ASHRAE www.ashrae.org. Used with permission from ASHRAE Journal. This article may not be copied nor distributed in either paper or digital form without ASHRAE s permission. For more information about ASHRAE,
More informationSystems and Technology Group. IBM Technology and Solutions Jan Janick IBM Vice President Modular Systems and Storage Development
Systems and Technology Group IBM Technology and Solutions Jan Janick IBM Vice President Modular Systems and Storage Development Power and cooling are complex issues There is no single fix. IBM is working
More informationUsing CFD Analysis to Predict Cooling System Performance in Data Centers Ben Steinberg, P.E. Staff Applications Engineer
Using CFD Analysis to Predict Cooling System Performance in Data Centers Ben Steinberg, P.E. Staff Applications Engineer Agenda What is CFD? Applications of CFD Applicability to the Data Center How it
More informationCFD Modeling of an Existing Raised-Floor Data Center
CFD Modeling of an Existing Raised-Floor Data Center Amir Radmehr 1, Brendan Noll 2, John Fitzpatrick 2, Kailash Karki 1 1. Innovative Research, Inc. 3025 Harbor Lane N, Suite 300, Plymouth, MN 2. University
More informationPassive RDHx as a Cost Effective Alternative to CRAH Air Cooling. Jeremiah Stikeleather Applications Engineer
Passive RDHx as a Cost Effective Alternative to CRAH Air Cooling Jeremiah Stikeleather Applications Engineer Passive RDHx as a Cost Effective Alternative to CRAH Air Cooling While CRAH cooling has been
More informationHow Liquid Cooling Helped Two University Data Centers Achieve Cooling Efficiency Goals. Michael Gagnon Coolcentric October
How Liquid Cooling Helped Two University Data Centers Achieve Cooling Efficiency Goals Michael Gagnon Coolcentric October 13 2011 Data Center Trends Energy consumption in the Data Center (DC) 2006-61 billion
More informationWhere s the Heat Coming From. Leland Sparks Global Account Technical Consultant Belden
Where s the Heat Coming From Leland Sparks Global Account Technical Consultant Belden What is the greatest DC challenge you face? Air Flow to Heat Load Relation Server Inlet Fans Chips Outlet LOAD Dell
More informationData Center Trends and Power Management
Data Center Trends and Power Management Roger Schmidt IBM Chief Thermal Architect Sept 12, 2006 Contents Power Trends/Impacts on Data Center IBM s Product Innovation Industry Actions Final thoughts What
More informationCurrent Data Center Design. James Monahan Sept 19 th 2006 IEEE San Francisco ComSoc
Current Data Center Design James Monahan Sept 19 th 2006 IEEE San Francisco ComSoc What is the biggest facility problem in your data center? 35% 30% 25% 20% 15% Series1 10% 5% 0% Excessive heat Insufficient
More informationImproving Data Center Efficiency
Improving Data Center Efficiency Controlling Bypass Airflow in your Data Center Bypass airflow can have a significant impact on the cooling capacity and efficiency of any data center. One key part of
More informationReclaim Wasted Cooling Capacity Now Updated with CFD Models to Support ASHRAE Case Study Data
White Paper EC9005A Reclaim Wasted Cooling Capacity Now Updated with CFD Models to Support ASHRAE Case Study Data Peer reviewed case study data from ASHRAE now updated with CFD model analysis revealing
More informationCHILLED WATER. HIGH PRECISION AIR CONDITIONERS, FROM 7 TO 211 kw
IT COOLING CLOSE CONTROL AIR CONDITIONERS CHILLED WATER HIGH PRECISION AIR CONDITIONERS, FROM 7 TO 211 kw 3 Versions available Single chilled water coil Double chilled water coil High temperature IT COOLING
More informationPower and Cooling for Ultra-High Density Racks and Blade Servers
Power and Cooling for Ultra-High Density Racks and Blade Servers APC White Paper #46 Richard L. Sawyer Director of Data Center Technology American Power Conversion Company 2005 APC corporation What has
More informationA Green Approach. Thermal
A Green Approach to Thermal Management Thermal Management - AGENDA Definitions & Thermal Facts Density Trends Rack Level Management Passive Solutions Thermal Sources & Green Solutions Data Center Layout
More informationNext Generation Cooling
Next Generation Cooling Server Manufacturer Perspective Practical and Cost Effective David Moss Data Center Strategist Dell 1 Why Chip, Row, or Rack? Density? Energy Don t be scared; I don t see 50kW/rack
More informationENCLOSURE HEAT DISSIPATION
ENCLOSURE HEAT DISSIPATION DATA CENTER SOLUTIONS A White Paper by Great Lakes Case & Cabinet Company www.werackyourworld.com 814.734.7303 Page 2 Introduction Dangerous heat levels inside an enclosure threaten
More informationAisleLok Modular Containment vs. Legacy Containment: A Comparative CFD Study of IT Inlet Temperatures and Fan Energy Savings
WHITE PAPER AisleLok Modular Containment vs. : A Comparative CFD Study of IT Inlet Temperatures and Fan Energy Savings By Bruce Long, Upsite Technologies, Inc. Lars Strong, P.E., Upsite Technologies, Inc.
More informationData Center Enclosures Best Practices. Maximize the Efficiency of the Enclosure within a Data Center
Data Center Enclosures Best Practices Maximize the Efficiency of the Enclosure within a Data Center Things to ask before selecting Enclosures: Primary Use Severs or Patching, or both determines size. RMU
More informationDatacenter Efficiency Trends. Cary Roberts Tellme, a Microsoft Subsidiary
Datacenter Efficiency Trends Cary Roberts Tellme, a Microsoft Subsidiary Power Slashing Tools P3 Kill-A-WATT Measures min, max, and instantaneous voltage and current draw Calculates power (watts), kilowatt
More informationMSYS 4480 AC Systems Winter 2015
MSYS 4480 AC Systems Winter 2015 Module 12: DATA CENTERS By Satwinder Singh 14/05/2015 1 Data Centers Data Centers are specialized environments that safeguard your company's most valuable equipment and
More information<Insert Picture Here> Austin Data Center 6Sigma DC CFD Model
Austin Data Center 6Sigma DC CFD Model Keith Ward Keith Ward Data Center Facilities Engineering and Logistics Design Austin Data Center Statistics - Space Original AT&T Designed and
More informationRittal Cooling Solutions A. Tropp
1 Rittal Cooling Solutions Presented by Adam Tropp 2 Agenda Cooling Strategies Aisle Containment Chimney Solution Airstream Management Rittal Liquid Cooling Packages Data Monitoring 3 Cooling strategies.
More informationSchneider Electric Cooling Portfolio. Jim Tubbesing Heath Wilson APC/Schneider North Texas Rep Tubbesing Solutions
Schneider Electric Cooling Portfolio Jim Tubbesing Heath Wilson APC/Schneider North Texas Rep Tubbesing Solutions Data Center Cooling Agenda 1. How to size data center, server rooms, IDF rooms, etc in
More informationHigh Tech Getting Too Hot? High Density Environments Require A Different Cooling Approach
High Tech Getting Too Hot? High Density Environments Require A Different Cooling Approach Proper airfl ow and thermal management are the most critical aspects of designing and operating your data center,
More informationReducing Data Center Cooling Costs through Airflow Containment
FEATURE Reducing Data Center Cooling Costs through Airflow Containment Implementing a containment solution in the data center costs much less than the alternatives of adding air handlers or other supplemental
More informationSmart Data Centres. Robert M Pe, Data Centre Consultant HP Services SEA
Smart Data Centres Robert M Pe, Data Centre Consultant Services SEA 2006 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice Content Data center
More informationENCLOSURE THERMAL TESTING HEAT REMOVAL IN THE REAL WORLD
R I T T A L T H E R M A L S E R I E S ENCLOSURE THERMAL TESTING HEAT REMOVAL IN THE REAL WORLD FRIEDHELM L O H GROUP I. INTRODUCTION As a leading manufacturer of enclosure solutions, Rittal is frequently
More informationThe Energy. David L. Moss Dell Data Center Infrastructure
The Energy Advantages of Containment Systems David L. Moss Dell Data Center Infrastructure www.dell.com/hiddendatacenter Summary The Uptime Institute estimates that the cost to build a new 20,000 square
More informationReducing Energy Consumption with
Reducing Energy Consumption with Passive Cooling Ian Cathcart, RCDD Technical Support Manager Technical Support Manager Chatsworth Products, Inc. Thermal Management: Mission Critical Data center heat loads
More informationThe Efficient Enterprise. All content in this presentation is protected 2008 American Power Conversion Corporation
Ee The Efficient Enterprise All content in this presentation is protected 2008 American Power Conversion Corporation Keystrokes Kilowatts Heat OUT Electricity IN Need for bandwidth exploding Going hyperbolic!
More informationApplication of TileFlow to Improve Cooling in a Data Center
Case Study Application of TileFlow to Improve Cooling in a Data Center 3025 Harbor Lane North, Suite 300 Plymouth, MN 55447 USA Copyright 2004 Innovative Research, Inc. 2 Introduction A large insurance
More informationA) Differences between Precision and Comfort Cooling Here are the major differences exist between precision air conditioning and comfort systems.
DATA CENTRE COOLING SYSTEM A) Differences between Precision and Comfort Cooling Here are the major differences exist between precision air conditioning and comfort systems. 1. Cooling Optimized to Electronic
More informationAirflow Management s Role in Data Center Cooling Capacity
Airflow Management s Role in Data Center Cooling Capacity By Larry Mainers, CEO Subzero Engineering 2014 Subzero Engineering SUMMARY Airflow management (AFM) is changing the way data centers cool the IT
More informationPackaging of New Servers - energy efficiency aspects-
Packaging of New Servers - energy efficiency aspects- Roger Schmidt, IBM Fellow Chief Engineer, Data Center Energy Efficiency Many slides provided by Ed Seminaro Chief Architect of HPC Power6 & 7 1 st
More informationIBM eserver Total Storage, On Demand
IBM eserver Total Storage, On Demand Bill Ott, Vice President, eserver xseries & IntelliStation Development Systems and Technology Group 10/7/2005 IBM 2Q 2005 Business Status Key Accomplishments Operational
More informationLiebert DCW CATALOGUE
Liebert DCW CATALOGUE Chilled Water-Based High Density Cooling For The Data Center LIEBERT DCW Flexible Approaches For Energy Efficient Cooling Save up to 70% in cooling energy usage Data center managers
More informationClose Coupled Cooling for Datacentres
Close Coupled Cooling for Datacentres Dr Fathi Tarada Mosen Ltd fathi.tarada@mosenltd.com www.mosenltd.com Agenda Increasing Power Densities Raised Floor Limitations Hot and Cold Aisle Enclosures Close
More informationImpact of Air Containment Systems
White Paper June 2012 WP-20 Impact of Air Containment Systems Reducing Energy Consumption Introduction: The Importance of Maintaining Data Center Cooling Energy Efficiency Data centers are mission-critical
More informationDATA CENTER LIQUID COOLING
DATA CENTER LIQUID COOLING EFFICIENT, EFFECTIVE, SUSTAINABLE What is Liquid Cooling? Key Trends & Potential Inhibitors Why are Many Owner/Operators Making the Move? Types of Liquid Cooling Solutions Liquid
More informationCombining Cold Aisle Containment with Intelligent Control to Optimize Data Center Cooling Efficiency
A White Paper from the Experts in Business-Critical Continuity TM Combining Cold Aisle Containment with Intelligent Control to Optimize Data Center Cooling Efficiency Executive Summary Energy efficiency
More informationLCP Hybrid Efficient performance with heat pipe technology
LCP Hybrid Efficient performance with heat pipe technology 2 LCP Hybrid The whole is more than the sum of its parts The same is true of "Rittal The System." With this in mind, we have bundled our innovative
More informationRear Door Heat Exchanger
Vinod Kamath Power and Thermal Engineering Sep 16, 2005 Problem Statement Rack Power loads are high due to increased compute density. The impact is seen in datacenters as high inlet air temperatures to
More informationEnergy Logic: Emerson Network Power. A Roadmap for Reducing Energy Consumption in the Data Center. Ross Hammond Managing Director
Energy Logic: A Roadmap for Reducing Energy Consumption in the Data Center Emerson Network Power Ross Hammond Managing Director Agenda Energy efficiency Where We Are Today What Data Center Managers Are
More informationInnovative Data Center Energy Efficiency Solutions
Innovative Data Center Energy Efficiency Solutions Dr. Hendrik F. Hamann IBM T.J. Watson Research Center 2/8/2009 2007 IBM Corporation A holistic Challenge: Energy & Thermal Management Energy / thermal
More informationTen Cooling Solutions to Support High-density Server Deployment. Schneider Electric Data Center Science Center White Paper #42
Ten Cooling Solutions to Support High-density Server Deployment Schneider Electric Data Center Science Center White Paper #42 1 Introduction 2 Introduction This paper provides 10 approaches for increasing
More informationVariable Density, Closed-Loop, Water-Cooled Data Center Solution
Variable Density, Closed-Loop, Water-Cooled Data Center Solution Overview Great Lakes Case & Cabinet Co., Inc. has worked with Naissus Thermal Management Solutions, of Toronto, Ontario to develop one of
More informationImproving Data Center Efficiency
Improving Data Center Efficiency Controlling Bypass Airflow in your Data Center Bypass airflow can have a significant impact on the cooling capacity and efficiency of any data center. One key part of
More information7 Best Practices for Increasing Efficiency, Availability and Capacity. XXXX XXXXXXXX Liebert North America
7 Best Practices for Increasing Efficiency, Availability and Capacity XXXX XXXXXXXX Liebert North America Emerson Network Power: The global leader in enabling Business-Critical Continuity Automatic Transfer
More informationCabinet Level Containment. IsoFlo Cabinet. Isolated Airfl ow Cabinet for Raised Floor Data Centers
Cabinet Level Containment IsoFlo Cabinet Isolated Airfl ow Cabinet for Raised Floor Data Centers IsoFlo Cabinet Cabinet Level Containment Tate s IsoFlo cabinet completely isolates the IT cooling from the
More informationLiebert DCW Family Chilled Water-Based High Density Cooling For The Data Center. Precision Cooling For Business-Critical Continuity
Liebert DCW Family Chilled Water-Based High Density Cooling For The Data Center Precision Cooling For Business-Critical Continuity Flexible Approaches For Energy Efficient Cooling Save up to 70% in cooling
More informationAPC APPLICATION NOTE #74
#74 Configuration of InfraStruXure for Data Centers to Support Dell PowerEdge 1855 Abstract Many companies are making plans to incorporate Dell PowerEdge Blade Servers into their data center applications.
More informationGreen Data Centers A Guideline
Green Data Centers A Guideline Sekhar Kondepudi Ph.D Associate Professor Smart Buildings & Smart Cities Vice Chair Focus Group on Smart Sustainable Cities ITU-TRCSL Workshop on Greening the Future: Bridging
More informationThermal management. Thermal management
Thermal management Thermal management Managing thermal loads is a major challenge for all Data Centre operators. Effecting proper control of the thermal environment drives energy consumption and ultimately
More informationMeasurement and Management Technologies (MMT) for more energy efficient Data Center and Telecommunication Facilities
Information and Communication Technology Portfolio Review San Francisco, CA March 2011 Project Name: Measurement and Management Technologies (MMT) for more energy efficient Data Center and Telecommunication
More informationOptimizing data centers for high-density computing
Optimizing data centers for high-density computing technology brief, 2nd edition Abstract... 2 Introduction... 2 Power consumption and heat load... 2 Power consumption... 2 Heat load... 5 The Need for
More information18 th National Award for Excellence in Energy Management. July 27, 2017
18 th National Award for Excellence in Energy Management July 27, 2017 ICICI Bank, Data Centre, August Hyderabad 30 & 31, 2017 ICICI Bank - Revolution in Digital Banking Over 100,000 Digital POS in 4 months
More informationBENEFITS OF ASETEK LIQUID COOLING FOR DATA CENTERS
BENEFITS OF ASETEK LIQUID COOLING FOR DATA CENTERS Asetek has leveraged its expertise as the world-leading provider of efficient liquid cooling systems to create its RackCDU and ISAC direct-to-chip liquid
More informationPower & Cooling Considerations for Virtualized Environments
Power & Cooling Considerations for Virtualized Environments Cisco Data Center Day 2008 31-01-2008 APC-MGE Vision & Mission OUR VISION APC-MGE products ensure availability wherever data is created, transmitted
More informationSwitch to Perfection
Switch to Perfection Traditional Data Centre - Temperatures Ideal Air Temperature: 22 C Chilled Water: 7-9 C Heat Load per Rack: Up to 4,5 Chilling & Pump Set The challenge a thermal image Front View of
More informationEfficiency of Data Center cooling
Efficiency of Data Center cooling Comparison of data room layouts and cooling systems Bohumil Cimbal Product manager for Cooling Systems in CONTEG Company Objective Basic questions between investor and
More informationIT Air Conditioning Units
IT Air Conditioning Units Modern Flexible Effective Energy Saving CoolTeg Plus and CoolTop overview CoolTeg Plus CW CoolTeg Plus DX CoolTeg Plus XC CoolTop Installation Between IT racks On top of IT rack
More informationAvoidable Mistakes that Compromise Cooling Performance in Data Centers and Network Rooms
Avoidable Mistakes that Compromise Cooling Performance in Data Centers and Network Rooms Problem Several cooling system mistakes are very common and avoidable Mistakes compromise availability and increase
More informationDATA CENTER EFFICIENCY: Data Center Temperature Set-point Impact on Cooling Efficiency
DATA CENTER EFFICIENCY: Data Center Temperature Set-point Impact on Cooling Efficiency September 27 th, 2013 Tejas Desai, PE CEM CEA LEED AP Sameer Behere, PE CEM LEED AP Agenda Problem: Quick fixes can
More informationPROCESS & DATA CENTER COOLING. How and Why To Prepare For What s To Come JOHN MORRIS REGIONAL DIRECTOR OF SALES
PROCESS & DATA CENTER COOLING How and Why To Prepare For What s To Come JOHN MORRIS REGIONAL DIRECTOR OF SALES CONGRATULATIONS 2 BOLD PREDICTION 3 Where We Are TODAY Computer Technology NOW advances more
More informationPower Monitoring in the Data Centre
Power Monitoring in the Data Centre Fixed or Wireless Steve Strange RCDD ANIXTER INTERNATIONAL Agenda Energy Consumption Case Study Reasons to Monitor Power Monitoring Environmental Monitoring Asset Tags
More informationREPORT. Energy Efficiency of the San Diego Supercomputer Center and Distributed Data Centers at UCSD. Prepared for:
REPORT Energy Efficiency of the San Diego Supercomputer Center and Distributed Data Centers at UCSD Prepared for: San Diego Supercomputer Center 10100 John J Hopkins Drive San Diego, CA 92037 May 11, 2009
More informationLiquid Cooling Package LCP Cooling Systems
Liquid Cooling Package LCP Cooling Systems 2 Rittal LCP The whole is more than the sum of its parts. The same is true of Rittal The System. With this in mind, we have bundled our innovative enclosure,
More informationMeasurement and Management Technologies (MMT)
IBM Systems Lab Services and Training Measurement and Management Technologies (MMT) Data Center Solutions for a Smarter Planet AGENDA IBM Energy Efficiency Program & Accomplishments IBM CO2 Reduction Commitment
More informationMEASURE MONITOR UNDERSTAND
MEASURE MONITOR UNDERSTAND Presented by Alistair Hunt Energy Monitoring, Measurement metrics Where and What 1 History & Background Company Timeline 18 Years Comrac & Sinetica founded 15 Years Raritan Integration
More informationRittal White Paper 506: Cold Aisle Containment for Improved Data Center Cooling Efficiency By: Daniel Kennedy
Rittal White Paper 506: Cold Aisle Containment for Improved Data Center Cooling Efficiency By: Daniel Kennedy Executive Summary Increasing power requirements for new servers have created the need to support
More informationA Data Center Heat Removal System That Saves... 80% Discover Inertech s Award-winning Data Center Heat Removal System
A Data Center Heat Removal System That Saves... Infrastructure Power Water up to 40% up to 80% up to 85% Discover Inertech s Award-winning Data Center Heat Removal System A Cool Solution; A Breakthrough
More informationHIGH DENSITY RACK COOLING CHOICES
WATERCOOLED HIGH PERFORMANCE COMPUTING SYSTEMS AQUILA WHITE PAPER HIGH DENSITY RACK COOLING CHOICES by Phil Hughes Reprinted with permission of Clustered Systems Company, Inc 1 THIS WHITE PAPER DISCUSSES
More informationNREL Validates LCS Technology. PRESENTED BY Herb Zien CEO, LiquidCool Solutions
NREL Validates LCS Technology PRESENTED BY Herb Zien CEO, LiquidCool Solutions Learning Objectives As much as 40% of data center power is used to circulate air, and fans in a typical 30-megawatt data center
More informationsurvey, 71% of respondents listed Improving capacity planning as a top driver for buying DCIM 1.
:: In a recent Uptime Institute survey, 71% of respondents listed Improving capacity planning as a top driver for buying DCIM 1. 2 Maintain Assess Control ROI Monitor Optimize The Need for a Better Approach
More informationCharles Nolan. Do more with less with your data centre A customer s perspective. Director IT Infrastructure, UNSW. Brought to you by:
Charles Nolan Director IT Infrastructure, UNSW Do more with less with your data centre A customer s perspective Brought to you by: Today s Enterprise Data Centre Doing more with less High Density Data
More informationPramod Mandagere Prof. David Du Sandeep Uttamchandani (IBM Almaden)
Pramod Mandagere Prof. David Du Sandeep Uttamchandani (IBM Almaden) Motivation Background Our Research Agenda Modeling Thermal Behavior Static Workload Provisioning Dynamic Workload Provisioning Improving
More informationPerformance Evaluation for Modular, Scalable Cooling Systems with Hot Aisle Containment in Data Centers. Final Report
Performance Evaluation for Modular, Scalable Cooling Systems with Hot Aisle Containment in Data Centers Final Report To The California Energy Commission May 2009 Tengfang Xu Environmental Energy Technologies
More informationImproving Data Center Reliability and Efficiency by Recovering Cooling Capacity with KoldLok Raised Floor Grommets BUSINESS CASE ANALYSIS
BUSINESS CASE ANALYSIS Improving Data Center Reliability and Efficiency by Recovering Cooling Capacity with KoldLok Raised Floor Grommets by Daniel L. Gollahon, CDP Subject: This business case examines
More informationHigh Density Cooling Solutions that work from Knurr Kris Holla
High Density Cooling Solutions that work from Knurr Kris Holla The Heat Goes On Ó by Knürr A An International Company Ranked #3 in the world Founded 1931 Strong international setting in over 32 countries
More informationProduct Brochure DENCO Close Control Units Row-DENCO. High Density Cooling for Data Centres
Product Brochure DENCO Close Control Units Row-DENCO High Density Cooling for Data Centres Data Centre Cooling Through a history in close control, we have developed a broad and deep understanding of how
More informationGreen IT. Finding Practical Efficiencies. Infrastructure Planning and Facilities. Green IT: Finding Practical Efficiencies
Green IT Finding Practical Infrastructure Planning and Facilities Dan Francis dfrancis@ipf.msu.edu David Graff dsgraff@ipf.msu.edu William Lakos wjlakos@ipf.msu.edu 1 2 MSU Historical Energy Efficiency
More informationData Center Infrastructure Management ( DCiM )
Page 1 Data Center Infrastructure Management ( DCiM ) DCiM is defined by technology researchers and analysts as the integration of information technology (IT) and facility management disciplines to centralize
More informationHP Modular Cooling System: water cooling technology for high-density server installations
HP Modular Cooling System: water cooling technology for high-density server installations technical brief Abstract... 2 Introduction... 2 Data center trends... 2 Increased power demands... 3 Increased
More informationGreen IT: reduce energy costs and improve service levels with virtualization Bob Good, Manager - Systems Engineers August 2009 MISA Fall Conference
Green IT: reduce energy costs and improve service levels with virtualization Bob Good, Manager - Systems Engineers August 2009 MISA Fall Conference Current State of the Data Center 2 Typical x86 Through
More information1.866.TRY.GLCC WeRackYourWorld.com
cool it. 1.866.TRY.GLCC WeRackYourWorld.com In order to maximize space in the data center and accommodate for increased data, rack-mount enclosures are becoming populated with high-density servers and
More informationPlanning for Liquid Cooling Patrick McGinn Product Manager, Rack DCLC
Planning for Liquid Cooling -------------------------------- Patrick McGinn Product Manager, Rack DCLC February 3 rd, 2015 Expertise, Innovation & Delivery 13 years in the making with a 1800% growth rate
More informationA LAYMAN S EXPLANATION OF THE ROLE OF IT RACKS IN COOLING YOUR DATA CENTER
A LAYMAN S EXPLANATION OF THE ROLE OF IT RACKS IN COOLING YOUR DATA CENTER By David Moss Dell Data Center Infrastructure dell.com/hiddendatacenter Many people see an IT rack as a glorified shelving system.
More informationAPC InRow Cooler Prototype Initial Report - Test Setup Verification. H. Coles, S. Greenberg Contributing: J. Bean (APC) November 18, 2011
APC InRow Cooler Prototype Initial Report - Test Setup Verification H. Coles, S. Greenberg Contributing: J. Bean (APC) November 18, 2011 1 Introduction Contents Technology Description/Attributes Installation
More informationCooling. Highly efficient cooling products for any IT application. For More Information: (866) DATA CENTER SOLUTIONS
Cooling > Highly efficient cooling products for any IT application. DATA CENTER SOLUTIONS For More Information: (866) 787-3271 Sales@PTSdcs.com End-to-End Cooling Solutions from the Closet to the Data
More informationHot vs Cold Energy Efficient Data Centers. - SVLG Data Center Center Efficiency Summit
Hot vs Cold Energy Efficient Data Centers - SVLG Data Center Center Efficiency Summit KC Mares November 2014 The Great Debate about Hardware Inlet Temperature Feb 2003: RMI report on high-performance data
More informationEvaporative free air cooling technology Providing evaporative free air cooling solutions.
Evaporative free air cooling technology Providing evaporative free air cooling solutions. Creating an effective workspace environment data centre free air cooling technology FreeCool - Evaporative Free
More informationCost Model Energy Benefits DirectAire & SmartAire Overview & Explanation
Cost Model Energy Benefits DirectAire & SmartAire Overview & Explanation A cost model (See figure 1) has been created to provide the user a simplified method for directly comparing the energy cost of a
More information