1 Enclosed DOL Starter Type x, Plastic, Phase C US LISTED ENCLOSED INDUSTRIAL CONTROL PANEL WIRING SPECIFICATIONS CONTROL/COIL VOLTAGE: LINE (LINE) START/STOP (STSR) START STOP //8 //8 Customer Supplied Power START STOP //8 //8 L T A L T A T T T T L T Phase A L T A L T T T T Phase L 9 CONTROL/COIL VOLTAGE: EXTERNAL SUPPLY START/STOP (STSR) Line Terminals IC009S.8S 0 awg lbin IC0S IC0S.0S IC00S.80S IC09S.0S 8 awg 8 awg /0 awg 0/0 awg lbin lbin 0 lbin 0 lbin IOLS awg 0 lbin I IOL0S...80S awg lbin IOL0S Load Terminals 8/0 awg lbin 9 CONTROL/COIL VOLTAGE: LINE (LINE) RESET ONLY (RSET) Customer Supplied Switch Customer Supplied Power Customer Supplied Switch L T A L T A T T T T L T Phase A L T A T T T Phase L L T 9 CONTROL/COIL VOLTAGE: EXTERNAL SUPPLY RESET ONLY (RSET) MOUNTING POSITION 9 Part Number Explanation EDOLPxxxxxxVNPxxxxxxxx UL Rating U / / / / 7/ Economy DirectOnLine Starter, PH Horsepower UL Type X, Plastic Operator Devices /Coil Suffix Description LINE and /Coil s are internally connected X0 Externally supplied VAC /Coil X0 Externally supplied 0VAC /Coil X0 X0 Externally supplied 080VAC /Coil Externally supplied 0VAC /Coil Operator Devices Suffix Description RSET Reset Pushbutton Only STSR Start/Stop and Reset Pushbuttons Current Trip Range ThreePhase, 0Hz 08V 0V 0V 0.8.A.8.8A.8.0A.0.A. 8.0A 7.0 0A 8.0.A A A A 0A 0 A 80A.8.8A.8.0A.0.A. 8.0A 7.0 0A 8.0.A A A 0A 0A 7 70A 80A 0.8.A.8.8A.8.0A.0.A. 8.0A 8.0.A 7A A A 7 97A 0A 0 7A 80A 7 97A ** The actual motor amps may be higher or lower than the average values listed above. Use actual motor current listed on the motor nameplate for a more reliable motor protection. OVERLOAD WARNING Toprovidecontinuedprotectionagainstfireor shock hazard, the complete overload relay must be replaced if burnout of one or more of the heater elements occurs. Setting the Full Load Current (FLA) Set the overload relay to full load current by adjusting dial () so that the set marking (red point) aligns with the desired current (). NOTE: Automatic reset is not intended for twowire control devices. Not suitable for Housing Renewable Overload Protective Devices Legend Circuit Field Wiring * Use 7 C Copper Conductors Only * Any device installed through enclosure must meet or exceed the environmental rating of the enclosure EDOLPPH09
2 Enclosed DOL Starter Dimensions Type x, Plastic, Phase, EP Frame Starter EP Frame Size: Reset Only EDOLP 0P 08V NP XXXX RSET EDOLP 0P7 08V NP XXXX RSET EDOLP 00 08V NP XXXX RSET EDOLP P 08V NP XXXX RSET EDOLP 00 08V NP XXXX RSET EDOLP 00 08V NP XXXX RSET EDOLP 00 08V NP XXXX RSET EDOLP 0P 0V NP XXXX RSET EDOLP 0P 0V NP XXXX RSET EDOLP 0P7 0V NP XXXX RSET EDOLP 00 0V NP XXXX RSET EDOLP P 0V NP XXXX RSET EDOLP 00 0V NP XXXX RSET EDOLP 00 0V NP XXXX RSET EDOLP 00 0V NP XXXX RSET EDOLP 0P 0V NP XXXX RSET EDOLP 00 0V NP XXXX RSET EDOLP 00 0V NP XXXX RSET EDOLP 00 0V NP XXXX RSET EDOLP 00 0V NP XXXX RSET EDOLP 007 0V NP XXXX RSET EDOLP 00 0V NP XXXX RSET Starter EP Frame Size: Start Stop/Reset EDOLP 0P 08V NP XXXX STSR EDOLP 0P7 08V NP XXXX STSR EDOLP 00 08V NP XXXX STSR EDOLP P 08V NP XXXX STSR EDOLP 00 08V NP XXXX STSR EDOLP 00 08V NP XXXX STSR EDOLP 00 08V NP XXXX STSR EDOLP 0P 0V NP XXXX STSR EDOLP 0P 0V NP XXXX STSR EDOLP 0P7 0V NP XXXX STSR EDOLP 00 0V NP XXXX STSR EDOLP P 0V NP XXXX STSR EDOLP 00 0V NP XXXX STSR EDOLP 00 0V NP XXXX STSR EDOLP 00 0V NP XXXX STSR EDOLP 0P 0V NP XXXX STSR EDOLP 00 0V NP XXXX STSR EDOLP 00 0V NP XXXX STSR EDOLP 00 0V NP XXXX STSR EDOLP 00 0V NP XXXX STSR EDOLP 007 0V NP XXXX STSR EDOLP 00 0V NP XXXX STSR EDOLPPH8
3 Enclosed DOL Starter Dimensions Type x, Plastic, Phase, EP Frame Starter EP Frame Size: Reset Only EDOLP V NP XXXX RSET EDOLP 00 08V NP XXXX RSET EDOLP 007 0V NP XXXX RSET EDOLP 00 0V NP XXXX RSET EDOLP 0 0V NP XXXX RSET EDOLP 00 0V NP XXXX RSET EDOLP 00 0V NP XXXX RSET Starter EP Frame Size: Start Stop/Reset EDOLP V NP XXXX STSR EDOLP 00 08V NP XXXX STSR EDOLP 007 0V NP XXXX STSR EDOLP 00 0V NP XXXX STSR EDOLP 0 0V NP XXXX STSR EDOLP 00 0V NP XXXX STSR EDOLP 00 0V NP XXXX STSR EDOLPPH8
4 Enclosed DOL Starter Dimensions Type x, Plastic, Phase, EP Frame Starter EP Frame Size: Reset Only EDOLP 0 08V NP XXXX STSR EDOLP 0 0V NP XXXX STSR EDOLP 00 0V NP XXXX STSR EDOLP 00 0V NP XXXX STSR Starter EP Frame Size: Start Stop/Reset EDOLP 0 08V NP XXXX RSET EDOLP 0 0V NP XXXX RSET EDOLP 00 0V NP XXXX RSET EDOLP 00 0V NP XXXX RSET EDOLPPH8
5 Enclosed DOL Starter Dimensions Type x, Plastic, Phase, EP Frame Starter EP Frame Size: Reset Only EDOLP 0 0V NP XXXX STSR EDOLP 00 0V NP XXXX STSR EDOLP 00 0V NP XXXX STSR EDOLP 07 0V NP XXXX STSR Starter EP Frame Size: Start Stop/Reset EDOLP 0 0V NP XXXX RSET EDOLP 00 0V NP XXXX RSET EDOLP 00 0V NP XXXX RSET EDOLP 07 0V NP XXXX RSET EDOLPPH8
Controls Enclosed Non-Combination Starters - PESW Series
NEMA 4/4X Non Metallic Enclosure Product Features WEG offers non-reversing and non-combination NEMA-4X magnetic starter up to 75HP at 460V. Featuring components that meet IEC design standards and UL horsepower
More informationSmartstart Control Module
Smartstart TECHNOLOGY What is Smartstart? The patented Smartstart control module is an integrated, seamless solution that incorporates operator control, superior motor protection, and automation system
More informationIPS INTELLIGENT PUMP STARTER
IPS INTELLIGENT PUMP STARTER The IPS Intelligent Pump Starter features SMARTSTART motor protection, integrated electronic pump protection overload, and power metering and data logging options. Ø & Ø, 0/60
More informationSMARTSTART MOTOR STARTERS
SMARTSTART MOTOR STARTERS MCG WWW.MCG-USA.COM 1 AT A GLANCE Covers all line voltages from 200-600V AC, single or three phase Transformer supplies a 24V AC coil voltage, no matter the line voltage 12V AC/DC
More informationEnclosed Non-Reversing Combination Controller, AC Operation - Type 1/12K/IP66 ➏➐ (KS7-C0C4R) Discount Schedule F-1
KWIKstarter/CX7 CX7 Non-Reversing Combination Controller, AC Enclosed Non-Reversing Combination Controller, AC Operation - Type 1/12K/IP66 ➏➐ ~ ~ ~ ~ 0.10 0.16 2.1 1 CX7-9-10- -AS0.16A-A10-PG 551 Q4 ~
More information3RM1 Hybrid Starters 6SIRIUS. contents. Industrial Controls Product Catalog 2017
3RM1 Hybrid Starters Industrial Controls Product Catalog 2017 Section contents 3RM1 Compact - Hybrid Starters Overview /2 General Data /3 Selection and ordering data /4 Accessories /5 - /9 Technical Data
More informationSLATE. Digital I/O Module INSTALLATION INSTRUCTIONS R8001D4001
SLATE Digital I/O Module R8001D4001 INSTALLATION INSTRUCTIONS Scan for more information Application SLATE brings configurable safety and programmable logic together into one single platform. The platform
More informationEnclosed Non-Reversing Combination Controller, AC Operation - Type 1/12K/IP66 ➏➐. Non-Metallic Type 1/12K/IP66 Enclosure (KS7-C0C4R)
KWIKstarter/CX7 CX7 Non-Reversing Combination Controller, AC Enclosed Non-Reversing Combination Controller, AC Operation - Type 1/12K/IP66 ➏➐ Catalog Number ➍➏➑➒ ~ ~ ~ ~ 0.10 0.16 2.1 1 CX7-9-10- -AS0.16A-A10-PG
More informationPACSystems* RX3i and Series IC693MDL940 / IC694MDL940
May 2015 PACSystems* RX3i and Series 90-30 IC693MDL940 / IC694MDL940 Output Module, Relay, NO, 2 Amp, 16 Point The Series 90*-30 and PACSystems * MDL940 2 Amp Relay Output module provides 16 normally-open
More informationTeSys IEC Contactors and Overload Relays
TeSys IEC Contactors and Overload Relays Making High-Fault Short-Circuit Current Ratings Simple Schneider Electric is an industry leader in IEC contactors and overload relays, and is recognized as the
More informationGS1 and GS2 Series AC Drives
GS1 and GS2 Series AC Drives Single Phase In 3 Phase Out Simple communications Each drive has a built-in Modbus RTU RS-485 communications port (RS-232/485 configurable on the GS2 series). An optional Ethernet
More informationPGR-3200 MANUAL INSULATION MONITOR
Tel: +1-800-832-3873 E-mail: techline@littelfuse.com www.littelfuse.com PGR-3200 MANUAL INSULATION MONITOR REVISION 3-E-040918 Copyright 2018 by Littelfuse, Inc. All rights reserved. Document Number: PM-1025-EN
More informationMini Contactors & Overloads
108 Mini s & Overloads GMC-12M Surface or DIN rail mountable UL508 compliant 1/ to 7-1/ 50/60Hz AC and DC versions available Direct-mounting overloads RoHS compliant Auxiliary contacts standard (1 N.0.)
More informationModel DMX8DIM Installation and Operations Manual
Model DMX8DIM Installation and Operations Manual Doug Fleenor Design, Inc. 396 Corbett Canyon Road Arroyo Grande, CA 93420 (805) 481-9599 Voice and FAX Manual revision June, 2018 Product description The
More informationMOTOR & CIRCUIT PROTECTION
2 MOTOR & CIRCUIT PROTECTION Motor Protection Circuit Breakers p2-1 Motor Protection Relays p2-13 Thermistor Protection Relay p2-18 Fuse Holders p2-20 Miniature Circuit Breakers p2-23 Residual Current
More information29 $ Manual Motor Starters FREESHIPPING. MOTOR CONTROLS 25. Features: MMS-32H Frame. MMS-63H Frame.
www.factorymation.com/motorcontrols MOTOR CONTROLS 25 Manual Motor Starters High interrupt capacity Din rail and surface mounting Lockable handle (OFF position) IP20 finger safe terminals Class 10 thermal
More informationMODELS DPDT DPDT DPDT-60MS DPDT-60MS
INSTALLATION INSTRUCTIONS Revision B1 Rapid City, SD, USA, 03/2010 MODELS 201-100-DPDT 201-200-DPDT 201-100-DPDT-60MS 201-200-DPDT-60MS II_201-XXX-DPDT_B1 II-201-DPDT-B BE SURE POWER IS DISCONNECTED PRIOR
More informationATS22D88S6U. ATS22D88S6U soft starter-ats22-control110v-power 208V(25hp)/230V(30hp)/460V(60hp)/575V(75hp) Product data sheet Characteristics.
Characteristics soft starter-ats22-control110v-power 208V(25hp)/230V(30hp)/460V(60hp)/575V(75hp) Main Range of product Altistart 22 Product or component type Product destination Product specific application
More informationSolar Combiner Enclosure
Installation Instructions Solar Combiner Enclosure Catalog Numbers 1000-SB006, 1000-SB012 Topic Page Description 1 Important Safety Instructions 3 Nameplate Data 4 Planning for Installation 4 Install the
More informationStarters. Power. Manual Motor Low Voltage Starters 600, 609, 609U, 609TU. 600 Manual Starting Switches 609 Manual Starting Switches
Starters Manual Motor Low Voltage Starters 600, 609, 609U, 609TU Compact design Undervoltage protection Manual operation with overload protection Ideal for low HP applications, up to 10 HP three phase
More informationOVERLOAD RELAYS POWER & ACTUATION PROVEN. series
POWER & ACTUATION OVERLOAD RELAYS series Need reliable, accurate overload and phase-loss protection for your motors? c3controls Series Bimetallic Overload Relays provide unmatched protection and can be
More informationSP SP-T-9
INSTALLATION INSTRUCTIONS Revision B1 Rapid City, SD, USA, 04/2010 MODELS 201-100-SP 201-200-SP 201-200-SP-T-9 II_201-SP_B1 2880 North Plaza Drive, Rapid City, South Dakota 57702 (800) 843-8848 (605) 348-5580
More informationBulletin 1489 Circuit Breakers. Selection Guide
Bulletin 1489 s Selection Guide Overview/Description Bulletin 1489-A s Energy-limiting design protects downstream components better than conventional breakers during short circuits Field-mountable options
More informationConveyor Belt Alignment Switches from IDEM
Conveyor Belt Alignment Switches from IDEM Data Sheet Die-Cast Models Python Line Series Stainless Steel Models Using Conveyor Belt Alignment Switches Application: Conveyor Belt Alignment switches are
More informationVEO. V2PF480Y/277VSY01 Art.Nr.: V2PF480Y/277VSY01P Art.Nr.: TECHNICAL DATA
Monitoring of phase sequence and phase loss Monitoring of asymmetry Supply voltage 208-480 V AC Supply circuit = measuring circuit 1 change-over contact Width 22,5 mm Control elements Asymmetry Status
More informationSECTION IDENTIFICATION FOR ELECTRICAL SYSTEMS
SECTION 26 05 53 IDENTIFICATION FOR ELECTRICAL SYSTEMS PART 1 GENERAL 1.1 SUMMARY A. Section Includes: 1. Nameplates. 2. Labels. 3. Wire markers. 4. Conduit markers. 5. Underground Warning Tape. 6. Lockout
More informationSeries Panel Mounted Control Devices
E_Master2012.qxd:NEW_E_Master_temp.qxd 1/27/12 4:28 PM Page 1 Series Features: Suitable for hazardous and corrosive locations. Installation is easy and precise. Devices fit into a standard 30.5mm, 1.2"
More informationFor normal duty, design the VFD voltage level at 480 Volt, 3 Phase, 60 Hertz. (In Canada, 600 Volt, 3 Phase, 60 Hertz.)
Introduction The Variable Frequency Drive Design Guidelines provides design criteria and specifications used in the procurement and application of variable frequency drives (VFDs). Table of Contents 1.
More information194E FA 32 E P11 P11 6
Bulletin E IEC Load Switches, A Product Selection/Catalog Number Explanation Bulletin E Enclosed Disconnect Load Switches with R Handles (with Defeater, suitable for padlocks) E-FA Painted Steel Enclosure
More informationSP500 AC Drive Installation and Operation Manual Version 3.1
SP500 AC Drive Installation and Operation Manual Version 3. Instruction Manual D2-3356-5 The information in this manual is subject to change without notice. Throughout this manual, the following notes
More informationMotor protection relays
Thermal overload relays for currents between 0.09 and 420A Electronic thermal overload relays for currents between 0.4 and A Electronic thermal overload relays with selectable tripping class: 5--20-30
More informationATS22C21S6U softstarter-ats22-control110vpower208v(60hp)/230v(75hp)/460v(150hp)/575v(200hp)
Characteristics softstarter-ats22-control110vpower208v(60hp)/230v(75hp)/460v(150hp)/575v(200hp) Main Range of product Altistart 22 Product or component type Product destination Product specific application
More informationQuick Start Guide TS A
Quick Start Guide TS 930 125-630A DANGER HAZARD OF ELECTRICAL SHOCK, EXPLOSION, OR ARC FLASH Read and understand this quick start guide before installing and operating the transfer switch The installer
More informationATS22D75S6 soft starter-ats22-control 220V-power 230V(18.5kW)/ V(37kW)/500V(45kW)
Characteristics soft starter-ats22-control 220V-power 230V(18.5kW)/400...440V(37kW)/500V(45kW) Price* : 683.00 GBP Main Range of product Altistart 22 Product or component type Product destination Product
More informationSECTION DISCONNECT SWITCHES
SECTION 16440 DISCONNECT SWITCHES PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and other Division 01 Specification
More informationATS22D17Q soft starter-ats22-control 220V-power 230V(4kW)/ V(7.5kW)
Characteristics soft starter-ats22-control 220V-power 230V(4kW)/400...440V(7.5kW) Main Range of product Altistart 22 Product or component type Product destination Product specific application Component
More informationIMS Control & EPR, We keep your motors running ABB s new control & protection devices up to 18.5 kw / 20 hp
IMS Control & EPR, 2010 01 29 We keep your motors running ABB s new control & protection devices up to 18.5 kw / 20 hp October 27, 2010 1SBC101089D0201 ABB s new control and protection devices Up to 18.5
More informationE-Series General Specifications
-Series General Specifications Ideally suited for higher amperage applications. Available with front and back mounting, screw terminals, stud terminals and heavy duty box wire connectors for solid wire
More informationBulletin 817 Thermistor Protection Relay
6 Bulletin 817 Accurate Temperature Monitoring for Critical Applications Automatic, Manual and Remote Reset Status Indicating LEDs DIN Rail or Panel Mounting Guarded Terminals IP20 1 N.O. and 1 N.C. Output
More informationZelio Control-modular measurement and control relays 1
Presentation, description 1 106439 RM35 TM111MW Presentation Motor temperature measurement and 50MW and RM35 TM250MW monitor the following, on 3-phase supplies: correct sequencing of phases L1, L2 and
More informationATS22C11S6U soft starter-ats22-control110vpower208v(30hp)/230v(40hp)/460v(75hp)/575v(100h
Characteristics soft starter-ats22-control110vpower208v(30hp)/230v(40hp)/460v(75hp)/575v(100h Complementary Assembly style Function available Power supply voltage limits Main Range of product Altistart
More informationCert.Record No _0_000, Class No , DQD No 557 Rev SUPPLEMENTARY PROTECTORS COMPONENT ACCEPTANCE PROGRAM
Seite 1 von 6 ACCEPTANCE RECORD File No: Class No: 016186_0_000 321530 SUPPLEMENTARY PROTECTORS COMPONENT ACCEPTANCE PROGRAM SUBMITTOR 4544043 E-T-A Circuit Breakers Limited 100 Leek Cr, Unit 11 Richmond
More informationATS22D17Q soft starter-ats22-control 220V-power 230V (4kW)/ V(7.5kW)
Product datasheet Characteristics ATS22D17Q soft starter-ats22-control 220V-power 230V (4kW)/400...440V(7.5kW) Complementary Assembly style Function available Supply voltage limits Main Range of product
More informationATS22D62Q soft starter-ats22-control 220V-power 230V(15kW)/ V(30kW)
Characteristics soft starter-ats22-control 220V-power 230V(15kW)/400...440V(30kW) Main Range of product Altistart 22 Product or component type Product destination Product specific application Component
More informationTempco Instruction Manual
Tempco Instruction Manual 1/16 DIN Solid State Temperature Controller Relay Output Solid State Output For Heating Model Numbers: TEC-901, TEC-902, TEC-905 Temperature controls in this series are designed
More informationINSTALLATION AND OPERATION MANUAL KBDF SERIES
INSTALLATION AND OPERATION MANUAL KBDF SERIES DIGITAL AC DRIVE IP-20 Enclosure Rated for 208 230 and 400/460 Volt 50 & 60 Hz 1/8 HP thru 5 HP 3-Phase AC Induction Motors Operates from 115, 208/230, and
More informationManual. Water Vend Controller Model ESDI WARNING! ELECTRICAL SHOCK HAZARD! AUTHORIZED PERSONNEL ONLY. EXPOSED 120 VAC ON CIRCUIT BOARD
Manual Water Vend Controller Model ESDI 030400 WARNING! ELECTRICAL SHOCK HAZARD! AUTHORIZED PERSONNEL ONLY. EXPOSED 120 VAC ON CIRCUIT BOARD THE CIRCUIT BOARD HAS MANY EXPOSED AREAS THAT ARE AT 120 VAC.
More informationEH175 SA F 1-1 C 4 L A
Reduced voltage starters Open & enclosed Description Compact, space saving design 16 starter frame sizes, B16 to EH00 Maximum U.L. horsepower ratings Mechanically interlocking as standard for wye-delta
More informationProduct Manual Pushbutton Station for Modicon Programmable Controller MODBUS Interface
Product Manual 8652 Pushbutton Station for Modicon Programmable Controller MODBUS Interface Quartech Corporation 15923 Angelo Drive Macomb Township, Michigan 48042-4050 Phone: (586) 781-0373 FAX: (586)
More informationPRODUCT PROFILE BULLETIN 193 & 592 E1 PLUS ELECTRONIC OVER LOAD RELAYS
PRODUCT PROFILE BULLETIN 193 & 592 E1 PLUS ELECTRONIC OVER LOAD RELAYS FEATURES IEC and NEMA configurations Self-Powered Phase Loss Protection Wide 5:1 Adjustment Range Over-Molded Power Connections 1
More informationChapter 2 Programmable Logic Controller (PLC) and Relay Ladder Logic (RLL).
Controller PLC and Relay LAdder Logic RLL -IE337 Chapter 2 Programmable Logic Controller (PLC) and Relay Ladder Logic (RLL). 1 Controller PLC and Relay LAdder Logic RLL -IE337 2.1 PLC Operation using scanning
More informationENERGY MANAGEMENT SOFT-STARTER THE MOST INTELLIGENT SOFT-STARTER YET
ES-RV 3Ø, 208 ~ 480V, 2-250HP ENERGY ANAGEENT SOFT-STARTER THE OST INTELLIGENT SOFT-STARTER YET Retaining the incredible features from the original ES such as Power metering & odbus RTU communications,
More informationTECHNICAL BROCHURE BCPNEMAST R0. NEMA Rated Three-Phase Starters BY EATON
TECHNICAL BROCHURE BCPNEMAST R0 NEMA Rated Three-Phase Starters BY EATON STANDARD FEATURES Series ECN - NEMA Rated Three-Phase Starters Adjustable Electronic Overloads C440 Series - Adjustable Class, Bi-metallic,
More informationMax. Back-up fuse [A] 50 ka, 690V AC 5 ka, 600V AC IEC/EN Coordination Type 1 Type 2
Bulletin T Product Selection Thermal Overload Relays For Use With C C Setting Range [A] gl/gg Max. Backup fuse [A] UL Class K ka, V AC ka, V AC IEC/EN Coordination Type Type UL.. TAA.. TAA.. TAA.. TAA..
More informationTable 1. IEC Power Control Devices. Type Description Cost Electrical Operations. Soft starters or drives that gradually start and stop motors.
IEC Power Control Devices Training Manual XT Training Module New Information March 08 Contents Description Page Overview..................... Contactors................... Overload Relays (Bimetal).......
More informationATS22C11S6U soft starter-ats22-control110vpower208v(30hp)/230v(40hp)/460v(75hp)/575v(100hp)
Characteristics soft starter-ats22-control110vpower208v(30hp)/230v(40hp)/460v(75hp)/575v(100hp) Product availability : Stock - Normally stocked in distribution facility Price* : 1468.00 USD Main Range
More informationInstallation, Operation and Maintenance Manual
Document 481200 VGD-100 Vari-Green Drive Installation, Operation and Maintenance Manual Please read and save these instructions for future reference. Read carefully before attempting to assemble, install,
More informationS.p.A. ISBN GC
E L E T T R O N I C A S.p.A. HPD N ( HPDN, HPDN, HPD8N, HPD16N,, HPD0N, HPD4N ) addendum to the instruction manual rev / add. 7.1 February 1998 (software rel. 4) ISBN GC010411004 New HPD version N Since
More informationModels beginning with 2M, 2L or 2X. Product Description. Technical Specifications. Installation Instructions. Series 2000 Multiple Meter Units (MMUs)
Models beginning with 2M, 2L or 2X Series 2000 Multiple Meter Units (MMUs) Product Description Technical Specifications Installation Instructions February 28 th, 2013 List of Figures...2 List of Tables...2
More informationMX1 Reversible AC Motor Controller. Supplementary Wiring Examples
MX1 Reversible AC Motor Controller Supplementary Wiring Examples DANGER Electrocution Hazard! Ensure all power is disconnected before servicing or wiring. Install all electrical equipment and wiring in
More informationSeries CA7 Contactors
C7 Series C7 Rugged, space saving and modular Sprecher + Schuh s newest contactor for applications up to 6HP Over years of design experience has produced Sprecher + Schuh s seventh generation contactor
More informationManual Motor Protectors
94 www.factorymation.com/motorcontrols MOTOR CONTROLS Manual Motor Protectors 30 IMM16 Frame IMM32 Frame IMM65 Frame E468295 E468295 High interrupt capacity up to 100kA (with optional current limiter)
More informationMicro Contactor MA Series
Relay-sized contactor, making it the world s smallest >3mm contact clearance acc. to IEC 60335-1 for Safety Applications Reversing contactor with mechanical interlock 3 Pole and 1 Aux. Contact NO or NC
More informationATS22D47S6U. Main. Range of product Altistart 22. Component name. Factory setting current. Utilisation category. IP degree of protection
Product datasheet Characteristics ATS22D47S6U Complementary Assembly style Function available Supply voltage limits Main Range of product Altistart 22 Product or component type Product destination Product
More information78 Series Electromechanical Relay Selection Guide
78 Series Electromechanical Relay Selection Guide Specification 781 Series 782 Series 783 Series 784 Series Coil Voltages Configuration SPDT DPDT 3PDT 4PDT Contact Rating 15A 15A 15A 15A Base Socket 5
More informationElectronic monitoring relays PMDsrange
Unit features Altdaten CMT For DC and AC supplies Normally energised mode Fault latching or automatic reset Normal/test mode External reset button can be connected Description The insulation monitoring
More informationATS22D75S6U. Main. Range of product Altistart 22. Component name. Factory setting current. Utilisation category. IP degree of protection
Product datasheet Characteristics ATS22D75S6U Complementary Assembly style Function available Supply voltage limits Main Range of product Altistart 22 Product or component type Product destination Product
More informationTC-9102 Series Surface Mount Temperature Controllers
TC-9102 Series Surface Mount Temperature Controllers General Description & Applications The TC-9102 Series Temperature Controller offers a versatile solution for a wide variety of applications that may
More informationATS22D75Q soft starter-ats22-control 220V-power 230V(18.5kW)/ V(37kW)
Product data sheet Characteristics ATS22D75Q soft starter-ats22-control 220V-power 230V(18.5kW)/400...440V(37kW) Complementary Assembly style Function available Power supply voltage limits Main Range of
More information1.1. Contactors and Starters... Contents Description Relays and Timers... Miniature Controls... Manual Motor Protectors. XT IEC Power Control
. Contents Description Relays and Timers......................... Miniature Controls......................... Contactors and Starters.................... Thermal Overload Relays.................... C440/XT
More informationE1 Plus Electronic Overload Relay
ROCKWELL AUTOMATION PROCUREMENT SPECIFICATION PROCUREMENT SPECIFICATION E1 Plus NOTICE: The specification guidelines in this document are intended to aid in the specification of products. Specific installations
More informationInstallation and Operation Manual D SP500 AC Drive. Version 3.1
Installation and Operation Manual D2-3356-6 SP500 AC Drive Version 3. Important User Information Solid-state equipment has operational characteristics differing from those of electromechanical equipment.
More informationEMS 1Ø, 120 ~ 230V, 1/10-25HP 3Ø, 200 ~ 600V, 1/2-300HP
ES, 120 ~ 230V, 1/10-25HP, 200 ~ 600V, 1/2-300HP ENERGY ANAGEENT STARTER T Smartstart THE OST INTELLIGENT STARTER YET Power metering, optional BACnet or odbus communications, and an intuitive interface
More informationSafety Contacts: AC models MA-1 thru 5, 10, 12, 13, 16 1 N/C MA-13, 16, 21 2 N/C DC models MA-12, 13, 14, 16 1 N/C MA-13, 15, 16, 20, 21 2 N/C
r Safety Interlock Switches MA Series MA Magnetically Actuated Safety Interlock Switches Large selection choose from a large selection of contact configurations housed in plastic to satisfy most application
More informationNew 30AA and 31AA Electronic Motor Protection Modules. Application Bulletin 128
New 30AA and 31AA Electronic Motor Protection Modules Application Bulletin 128 Application Bulletin Number: 128 Release EN: D09910 Date: 4/19/96 Revision EN: Z27301 Date: 10/2/15 Subject: New 30AA and
More informationFor full product information, visit Use the SpeedSpec code or scan the QR Code for quick access to the specific web page.
R Safety Interlock Switches MA Series MA For full product information, visit www.sti.com. Use the SpeedSpec code or scan the QR Code for quick access to the specific web page. Magnetically Actuated Safety
More informationPowerFlex 400 AC Drive Guide Specification
PowerFlex 400 AC Drive Guide Specification Adjustable Frequency Drives with Bypass 3.0 50HP @ 208V AC 3.0 350HP @ 480V AC PART 1 GENERAL 1.01 Quality Assurance A. The manufacturer shall have minimum 5
More informationWiring Diagrams UNITS WITH STARTING SERIAL NUMBER 3507Q
AQUASNAP 30RB060-390 Air-Cooled Liquid Chillers with COMFORTLINK Controls 60 Hz Wiring Diagrams UNITS WITH STARTING SERIAL NUMBER 3507Q INDEX* POWER SCHEMATICS 30RB Unit Size Voltage Figure Number Label
More informationGV3000/SE AC Drive 1-20 HP, 230V AC
Hardware Reference, Installation, and Troubleshooting Manual D2-3388-5 GV3000/SE AC Drive - 20 HP, 230V AC Version 6.04 Important User Information Solid-state equipment has operational characteristics
More informationRM22TG. Product data sheet Characteristics. three-phase control relay Vac, 2 C/O. Main. Complementary. Network number of phases
Characteristics three-phase control relay 183 528Vac, 2 C/O Main Range of product Product or component type Relay type Network number of phases Relay name Relay monitored parameters Time delay type Switching
More informationVEO. V2UF230V10 Art.Nr.: TECHNICAL DATA
Continous voltage monitoring Mains fluctuation detection Detects voltage drop / short interruptions of at least 10ms Prevents undefined states in switching and control systems Generates reset pulse after
More information.2 Section General Commissioning (Cx) Requirements. .3 Section Common Work Requirements - Electrical
Issued for Review Section 26 28 16.01 Air Circuit Breakers Page 1 of 7 PART 1 GENERAL 1.1 GENERAL.1 This specification serves to define requirements for a replacement of low voltage circuit breaker of
More informationSet up and verify the operation of basic motor starters. Understand the purpose of a separate control circuit.
Exercise 3-1 Motor Starters EXERCISE OBJECTIVE Set up and verify the operation of basic motor starters. Understand the purpose of a separate control circuit. DISCUSSION OUTLINE The Discussion of this exercise
More informationJockey Pump Controllers
BR081001EN Microprocessor Based with Color Touchscreen Product Description ACROSS THE LINE Controllers operate across-the-line. Full voltage is applied to the motor for starting by the use of a single
More information02/11/2015
DIN Rail Mount 22.5 mm ETM2 Part number 84874023 Version ETM : Controls temperature of machines using built-in PTC probes Line break or probe short-circuit detection Version ETM2 / ETM22 : Fault latching
More informationFor full product information, visit Use the SpeedSpec code or scan the QR Code for quick access to the specific web page.
R Safety Monitoring Relays For full product information, visit www.sti.com. Use the SpeedSpec code or scan the QR Code for quick access to the specific web page. Dual-Channel Safety Monitoring Relay Power
More informationOrdering Key. Type Rated Operational Rated operational Control Voltage Uc Options
otor Controllers AC Semiconductor otor Controller Type RSHR 3-Phase Soft starting and stopping of 3-phase squirrel cage motors Control of all 3 phases In Line or In Delta motor connection Low inrush and
More informationRW-E. Overloads. Solid-State Overload Relays. Standard Features
RW-E The new RW_E Solid State Overload relays are developed with cutting edge technology according to the most demanding standards worldwide. With its wide current/mp setting; the RW_E OL Relay can be
More informationInstallation Manual Updated May 2017
Code No. LIT-12012114 Installation Manual Updated May 2017 JC-VSD Factory Packaged (FP) Series II drive frames 4 8, Type 1 and 3R Johnson Controls variable speed drives Disclaimer of warranties and limitation
More informationJockey Pump Controllers
BR081001EN Microprocessor Based with Color Touchscreen Product Description ACROSS THE LINE Controllers operate across-the-line. Full voltage is applied to the motor for starting by the use of a single
More informationINSTALLATION INSTRUCTIONS
LIGHTING CONTROL PANELS 16 AND 24 RELAYS INSTALLATION INSTRUCTIONS INSTALLATION OVERVIEW The installation instructions contained in this document are provided as a guide for proper and reliable installation.
More informationSlim Relay G2RV. Model Number Structure. Ordering Information. Model Number Legend. List of Models. Relay and Socket Combinations
Slim Relay G2RV The World's First Industrial Slim Relay Large plug-in terminals for reliable connection. LED indicator and mechanical flag to check operation. Transparent housing enables checking relay
More informationRiLine Compact The smart power distribution system
RiLine Compact The smart power distribution system 2 Power distribution in a confined space Rittal are the leading suppliers of reliable power distribution and backup systems for controlgear. The new RiLine
More informationGV3000/SE AC Drive Hardware Reference, Installation, and Troubleshooting VAC Version 6.04
GV3000/SE AC Drive Hardware Reference, Installation, and Troubleshooting -20 HP @ 230 VAC Version 6.04 c Instruction Manual D2-3388-4 The information in this manual is subject to change without notice.
More informationCircuit Breakers Type CTI 25M, CTI 45MB
Data sheet Circuit Breakers Type CTI 25M, CTI 45MB Circuit breakers for short circuit and overload protection of motor applications cover the current range 0.1 45 A (AC-3 rating). The product range is
More informationATS22C41Q soft starter-ats22-control 220V-power 230V(110kW)/ V(220kW)
Characteristics soft starter-ats22-control 220V-power 230V(110kW)/400...440V(220kW) Complementary Assembly style Function available Power supply voltage limits Main Range of product Altistart 22 Product
More informationRated operational Control Voltage Uc Supply Voltage Connection Rated operational current 40 C voltage Ue Us 25A AC-53a 32A AC-53a
otor Controllers AC Semiconductor otor Controller Type RSHR 3-Phase Soft starting and stopping of 3-phase squirrel cage motors Control of all 3 phases In Line or In Delta motor connection Low inrush and
More informationBulletin 1492-MC 1492-MCGA, -MCEA 1492-SP
Bulletin Control Circuit and Load Protection Product Overview Bulletin -MC -MCGA, -MCEA -SP Type Branch Ground Fault Detection Features /V, V & Y/V rating A interrupt / in. per pole wide... A @ UL Circuit
More informationMini Contactors. Mini Contactor Relays 4-pole 20 Auxiliary Contact Blocks. Interface Contactor Relays. Mini Contactors 22 Auxiliary Contact Blocks
Mini Contactors Mini Contactor Relays 4-pole 20 Auxiliary Contact Blocks Interface Contactor Relays Mini Contactors 22 Auxiliary Contact Blocks Mini Contactors With Fast On Tab Connectors 24 Mini Contactors
More informationINSTALLATION AND OPERATION MANUAL KBMK SERIES. Adjustable Frequency Drives for 1/8 HP thru 1 HP 3-Phase AC Motors Rated VAC, 50/60 Hz
INSTALLATION AND OPERATION MANUAL KBMK SERIES Adjustable Frequency Drives for 1/8 HP thru 1 HP 3-Phase AC Motors Rated 208 230 VAC, 50/60 Hz NEMA 1 / IP40 Operate from 115* and 208/230 Volt 50/60 Hz AC
More information