EH175 SA F 1-1 C 4 L A

Size: px
Start display at page:

Download "EH175 SA F 1-1 C 4 L A"

Transcription

1 Reduced voltage starters Open & enclosed Description Compact, space saving design 16 starter frame sizes, B16 to EH00 Maximum U.L. horsepower ratings Mechanically interlocking as standard for wye-delta and autotransformer starters Incomplete sequence timer as standard for wye-delta and autotransformer starters Remote customer connection point at separate terminal blocks Easy removal of arc chute for quick inspection and change of contacts Double break contact design with magnetic arc chamber extinguishes arc in the shortest possible time Class 10 adjustable overload relays: - Single phase & phase unbalance protection - Isolated alarm circuit (N.O.) contact - Ambient compensation from -20 o C to +65 o C - Manual test - Manual or automatic reset - Factory calibrated and tested - Self-contained heater coils no field installation is necessary (included in price) - Wide adjustment range - Class 30 overload available on EH175 EH00 Index Reduced voltage starters Features....1 Auto-transformer type...2 Wye-delta, open transition...4 Wye-delta, closed transition....6 Part winding... Circuit diagrams Approximate dimensions Starter Size Starter Type SA - Autotransformer SG - Wye-Delta Open Transition SY - Wye-Delta Closed Transition SH - Part Winding Combination Type No digit Non-Combination N - Non-Fusible Disconnect F - Fusible Disconnect B - Thermal Magnetic Circuit Breaker M - Motor Circuit Protection (MCP) Enclosure No Digit - Open 1 - NEMA NEMA NEMA 3R 4 - NEMA 4 X - NEMA 4X Coil Voltage See Voltage Selection chart Overload Range See Overload Relay Selection chart EH175 SA F 1-1 C 4 L A REDUCED VOLTAGE STARTERS: Selection: Circuit diagrams: Approximate dimensions: Accessories A Start-stop pushbutton C 2 pos. sel. switch D 3 pos. sel. switch E Pilot light F Start-stop pushbutton & pilot light H 2 pos. sel. switch & pilot light J 3 pos. sel. switch & pilot light Horsepower A 10 N 200 B 15 P 250 C 20 R 300 D 25 S 350 E 30 T 400 F 40 U 500 G 50 V 600 H 60 W 700 J 75 X 00 K 100 Y 900 L 125 Z 1000 M 150 Line Voltage V V V V.1

2 Reduced voltage starters Auto-transformer non-combination type 3 Pole, open & enclosed General purpose current Maximum ratings UL Listed Maximum motor horsepower ratings 200V 230V 460/40V 575/600V UL rated Open type NEMA 1 (Indoor metal) Catalog List Catalog List number price number price B16SA-1 $ 265 B16SA1-1 $ B25SA B25SA B40SA B40SA B50SA B50SA B63SA B63SA B75SA-1 35 B75SA A110SA A110SA EH145SA EH145SA EH175SA EH175SA1-1 11, EH210SA-1 11,464 EH210SA1-1 13, EH260SA-1 13,113 EH260SA1-1 14, EH300SA-1 16,02 EH300SA1-1 17, EH450SA-1 20,664 EH450SA1-1 21, EH550SA-1 23,95 EH550SA1-1 26, EH700SA-1 35,041 EH700SA1-1 37, EH00SA-1 39,500 EH00SA1-1 41,745 NEMA rated NEMA size Continuous current BN16SA-1 $ 265 BN16SA1-1 $ BN25SA BN25SA BN50SA BN50SA BN75SA-1 35 BN75SA EHN145SA EHN145SA EHN260SA-1 13,113 EHN260SA1-1 14, EHN550SA-1 23,95 EHN550SA1-1 26, EHN00SA-1 39,500 EHN00SA1-1 41,745 Overload Relay suffix code. Select from the Overload Relay Selection chart on back cover fold out page. Coil voltage selection chart Hz Contr. Volts Control transformers type / / / / A,B,EH F G 1 B 2 C A,B F EH N 1 J 3 M 5 DC A,B,EH Y W P Q R T For other voltages, consult factory. 24 & 4VAC coils are not available for sizes EH450 - EH00. For these applications, use an interposing control relay. Coil voltage selection All catalog numbers include a 120V coil. To select other coil voltages, substitute the code from the Coil Voltage Selection Chart for the first digit after the dash in the catalog number. D.C. operated starters If DC operation is required, consult factory. REDUCED VOLTAGE STARTERS: Selection: Circuit diagrams: Approximate dimensions: Open Enclosed Type A, B, EH Discount schedule RV RVE

3 Reduced voltage starters Auto-transformer non-combination type NEMA 3R NEMA 12 NEMA 4 NEMA 4X (Outdoor Metal) (Metal Dustight) (Watertight) (Stainless Steel) Catalog List Catalog List Catalog List Catalog List number price number price number price number price UL rated B16SA3-1 $ 32 B16SA2-1 $ 32 B16SA4-1 $ 4662 B16SAX-1 $ 5700 B25SA B25SA B25SA B25SAX B40SA B40SA B40SA B40SAX B50SA B50SA B50SA B50SAX B63SA B63SA B63SA B63SAX B75SA B75SA B75SA B75SAX A110SA A110SA A110SA A110SAX EH145SA EH145SA EH145SA4-1 11,322 EH145SAX-1 12,200 EH175SA3-1 12,64 EH175SA2-1 12,64 EH175SA4-1 14,634 EH175SAX-1 16,300 EH210SA3-1 14,561 EH210SA2-1 14,561 EH210SA4-1 16,541 EH210SAX-1 1,400 EH260SA3-1 16,065 EH260SA2-1 16,065 EH260SA4-1 17,65 EH260SAX-1 19,600 EH300SA3-1 1,927 EH300SA2-1 1,927 EH300SA4-1 20,79 EH300SAX-1 22,000 EH450SA3-1 23,49 EH450SA2-1 23,49 EH450SA4-1 25,71 EH450SAX-1 27,450 EH550SA3-1 2,371 EH550SA2-1 2,371 EH550SA4-1 30,621 EH550SAX-1 33,00 EH700SA3-1 39,99 EH700SA2-1 39,99 EH700SA4-1 41,549 EH700SAX-1 45,00 EH00SA3-1 43,995 EH00SA2-1 43,995 EH00SA4-1 46,245 EH00SAX-1 50,200 NEMA rated BN16SA3-1 $ 32 BN16SA2-1 $ 32 BN16SA4-1 $ 4662 BN16SAX-1 $ 5700 BN25SA BN25SA BN25SA BN25SAX BN50SA BN50SA BN50SA BN50SAX BN75SA BN75SA BN75SA BN75SAX EHN145SA EHN145SA EHN145SA4-1 11,322 EHN145SAX-1 12,200 EHN260SA3-1 16,065 EHN260SA2-1 16,065 EHN260SA4-1 17,65 EHN260SAX-1 19,600 EHN550SA3-1 2,371 EHN550SA2-1 2,371 EHN550SA4-1 30,621 EHN550SAX-1 33,00 EHN00SA3-1 43,995 EHN00SA2-1 43,995 EHN00SA4-1 46,245 EHN00SAX-1 50,200 Overload Relay suffix code. Select from the Overload Relay Selection chart on back cover fold out page. REDUCED VOLTAGE STARTERS: Selection: Circuit diagrams: Approximate dimensions: Open Enclosed Type A, B, EH Discount schedule RV RVE.3

4 Reduced voltage starters Wye-delta, open transition 3 Pole, open & enclosed General purpose current Maximum ratings UL Listed Maximum motor horsepower ratings 200V 230V 460/40V 575/600V UL rated Open type NEMA 1 (Indoor metal) Catalog List Catalog List number price number price B25SG-1 $ 2025 B25SG1-1 $ B30SG B30SG B40SG B40SG B50SG B50SG B63SG B63SG B75SG B75SG A110SG-1 59 A110SG EH145SG EH145SG EH175SG EH175SG EH210SG-1 10,332 EH210SG1-1 11, EH260SG-1 11,973 EH260SG1-1 13, EH300SG-1 17,300 EH300SG1-1 1, EH450SG-1 24,000 EH450SG1-1 25, EH550SG-1 26,337 EH550SG1-1 2, EH700SG-1 32,939 EH700SG1-1 34, EH00SG-1 36,267 EH00SG1-1 3,403 NEMA rated NEMA size Continuous current 1YD BN25SG-1 $ 2025 BN25SG1-1 $ YD BN50SG BN50SG YD BN75SG BN75SG YD EHN145SG EHN145SG YD EHN260SG-1 11,973 EHN260SG1-1 13,305 6YD EHN550SG-1 26,337 EHN550SG1-1 2,473 7YD EHN00SG-1 36,267 EHN00SG1-1 3,403 Overload Relay suffix code. Select from the Overload Relay Selection chart on back cover fold out page. Coil voltage selection chart Hz Contr. Volts Control transformers type / / / / A,B,EH F G 1 B 2 C A,B F EH N 1 J 3 M 5 DC A,B,EH Y W P Q R T For other voltages, consult factory. 24 & 4VAC coils are not available for sizes EH450 - EH00. For these applications, use an interposing control relay. Coil voltage selection All catalog numbers include a 120V coil. To select other coil voltages, substitute the code from the Coil Voltage Selection Chart for the first digit after the dash in the catalog number. D.C. operated starters If DC operation is required, consult factory. REDUCED VOLTAGE STARTERS: Selection: Circuit diagrams: Approximate dimensions: Open Enclosed Type A, B, EH Discount schedule WD WDE

5 Reduced voltage starters Wye-delta, open transition NEMA 3R NEMA 12 NEMA 4 NEMA 4X (Outdoor Metal) (Metal Dustight) (Watertight) (Stainless Steel) Catalog List Catalog List Catalog List Catalog List number price number price number price number price UL rated B25SG3-1 $ 2661 B25SG2-1 $ 2661 B25SG4-1 $ 271 B25SGX-1 $ 3200 B30SG B30SG B30SG B30SGX B40SG B40SG B40SG B40SGX B50SG B50SG B50SG B50SGX B63SG B63SG B63SG B63SGX B75SG B75SG B75SG B75SGX A110SG A110SG A110SG A110SGX EH145SG EH145SG EH145SG EH145SGX-1 10,25 EH175SG EH175SG EH175SG4-1 10,100 EH175SGX-1 12,100 EH210SG3-1 12,143 EH210SG2-1 12,143 EH210SG4-1 12,690 EH210SGX-1 14,300 EH260SG3-1 14,925 EH260SG2-1 14,925 EH260SG4-1 16,725 EH260SGX-1 1,225 EH300SG3-1 20,255 EH300SG2-1 20,255 EH300SG4-1 21,025 EH300SGX-1 23,650 EH450SG3-1 27,433 EH450SG2-1 27,433 EH450SG4-1 2,544 EH450SGX-1 31,050 EH550SG3-1 30,723 EH550SG2-1 30,723 EH550SG4-1 32,973 EH550SGX-1 34,600 EH700SG3-1 36,34 EH700SG2-1 36,34 EH700SG4-1 3,522 EH700SGX-1 40,950 EH00SG3-1 40,653 EH00SG2-1 40,653 EH00SG4-1 42,903 EH00SGX-1 46,750 NEMA rated BN25SG3-1 $ 2661 BN25SG2-1 $ 2661 BN25SG4-1 $ 271 BN25SGX-1 $ 3200 BN50SG BN50SG BN50SG BN50SGX BN75SG BN75SG BN75SG BN75SGX EHN145SG EHN145SG EHN145SG EHN145SGX-1 10,25 EHN260SG3-1 14,925 EHN260SG2-1 14,925 EHN260SG4-1 16,725 EHN260SGX-1 1,225 EHN550SG3-1 30,723 EHN550SG2-1 30,723 EHN550SG4-1 32,973 EHN550SGX-1 34,600 EHN00SG3-1 40,653 EHN00SG2-1 40,653 EHN00SG4-1 42,903 EHN00SGX-1 46,750 Overload Relay suffix code. Select from the Overload Relay Selection chart on back cover fold out page. REDUCED VOLTAGE STARTERS: Selection: Circuit diagrams: Approximate dimensions: Open Enclosed Type A, B, EH Discount schedule WD WDE.5

6 Reduced voltage starters Wye-delta closed transition 3 Pole, open & enclosed General purpose current Maximum ratings UL Listed Maximum motor horsepower ratings 200V 230V 460/40V 575/600V UL rated Open type NEMA 1 (Indoor metal) Catalog List Catalog List number price number price B25SY-1 $ 3111 B25SY1-1 $ B30SY B30SY B40SY B40SY B50SY B50SY B63SY B63SY B75SY B75SY A110SY A110SY1-1 10, EH145SY EH145SY1-1 10, EH175SY-1 13,449 EH175SY1-1 14, EH210SY-1 15,369 EH210SY1-1 16, EH260SY-1 16,275 EH260SY1-1 17, EH300SY-1 21,375 EH300SY1-1 24, EH450SY-1 26,575 EH450SY1-1 2, EH550SY-1 33,61 EH550SY1-1 35, EH700SY-1 43,940 EH700SY1-1 45, EH00SY-1 47,661 EH00SY1-1 49,797 NEMA rated NEMA size Continuous current 1YD BN25SY-1 $ 3111 BN25SY1-1 $ YD BN50SY BN50SY YD BN75SY BN75SY YD EHN145SY EHN145SY1-1 10,215 5YD EHN260SY-1 16,275 EHN260SY1-1 17,607 6YD EHN550SY-1 33,61 EHN550SY1-1 35,17 7YD EHN00SY-1 47,661 EHN00SY1-1 49,797 Overload Relay suffix code. Select from the Overload Relay Selection chart on back cover fold out page. Coil voltage selection chart Hz Contr. Volts Control transformers type / / / / A,B,EH F G 1 B 2 C A,B F EH N 1 J 3 M 5 DC A,B,EH Y W P Q R T For other voltages, consult factory. 24 & 4VAC coils are not available for sizes EH450 - EH00. For these applications, use an interposing control relay. Coil voltage selection All catalog numbers include a 120V coil. To select other coil voltages, substitute the code from the Coil Voltage Selection Chart for the first digit after the dash in the catalog number. D.C. operated starters If DC operation is required, consult factory. REDUCED VOLTAGE STARTERS: Selection: Circuit diagrams: Approximate dimensions: Open Enclosed Type A, B, EH Discount schedule WD WDE

7 Reduced voltage starters Wye-delta closed transition NEMA 3R NEMA 12 NEMA 4 NEMA 4X (Outdoor Metal) (Metal Dustight) (Watertight) (Stainless Steel) Catalog List Catalog List Catalog List Catalog List number price number price number price number price UL rated B25SY3-1 $ 3747 B25SY2-1 $ 3747 B25SY4-1 $ 367 B25SYX-1 $ 4300 B30SY B30SY B30SY B30SYX B40SY B40SY B40SY B40SYX B50SY B50SY B50SY B50SYX B63SY B63SY B63SY B63SYX B75SY B75SY B75SY B75SYX A110SY3-1 11,271 A110SY2-1 11,271 A110SY4-1 11,913 A110SYX-1 12,900 EH145SY3-1 11,415 EH145SY2-1 11,415 EH145SY4-1 12,057 EH145SYX-1 13,300 EH175SY3-1 15,315 EH175SY2-1 15,315 EH175SY4-1 1,957 EH175SYX-1 20,150 EH210SY3-1 1,321 EH210SY2-1 1,321 EH210SY4-1 20,121 EH210SYX-1 21,600 EH260SY3-1 19,227 EH260SY2-1 19,227 EH260SY4-1 21,027 EH260SYX-1 22,300 EH300SY3-1 23,327 EH300SY2-1 23,327 EH300SY4-1 25,127 EH300SYX-1 27,125 EH450SY3-1 27,500 EH450SY2-1 27,500 EH450SY4-1 30,220 EH450SYX-1 32,450 EH550SY3-1 3,067 EH550SY2-1 3,067 EH550SY4-1 40,317 EH550SYX-1 44,600 EH700SY3-1 4,499 EH700SY2-1 4,499 EH700SY4-1 50,422 EH700SYX-1 55,750 EH00SY3-1 52,047 EH00SY2-1 52,047 EH00SY4-1 54,297 EH00SYX-1 59,150 NEMA rated BN25SY3-1 $ 3747 BN25SY2-1 $ 3747 BN25SY4-1 $ 367 BN25SYX-1 $ 4300 BN50SY BN50SY BN50SY BN50SYX BN75SY BN75SY BN75SY BN75SYX EHN145SY3-1 11,415 EHN145SY2-1 11,415 EHN145SY4-1 12,057 EHN145SYX-1 13,300 EHN260SY3-1 19,227 EHN260SY2-1 19,227 EHN260SY4-1 21,027 EHN260SYX-1 22,300 EHN550SY3-1 3,067 EHN550SY2-1 3,067 EHN550SY4-1 40,317 EHN550SYX-1 44,600 EHN00SY3-1 52,047 EHN00SY2-1 52,047 EHN00SY4-1 54,297 EHN00SYX-1 59,150 Overload Relay suffix code. Select from the Overload Relay Selection chart on back cover fold out page. REDUCED VOLTAGE STARTERS: Selection: Circuit diagrams: Approximate dimensions: Open Enclosed Type A, B, EH Discount schedule WD WDE.7

8 Reduced voltage starters Part winding non-reversing 3 Pole, open & enclosed General purpose current Maximum ratings UL Listed Maximum motor horsepower ratings 200V 230V 460/40V 575/600V UL rated Open type NEMA 1 (Indoor metal) Catalog List Catalog List number price number price B25SH-1 $ 127 B25SH1-1 $ B30SH B30SH B40SH B40SH B50SH B50SH B63SH B63SH B75SH B75SH A110SH A110SH EH145SH EH145SH EH175SH EH175SH EH210SH EH210SH EH260SH-1 11,166 EH260SH1-1 11, EH300SH-1 20,394 EH300SH1-1 21, EH450SH-1 24,000 EH450SH1-1 24, EH550SH-1 22,590 EH550SH1-1 2, EH700SH-1 2,105 EH700SH1-1 34, EH00SH-1 33,996 EH00SH1-1 37,776 NEMA rated NEMA size Continuous current 1PW BN25SH-1 $ 127 BN25SH1-1 $ PW BN50SH BN50SH PW BN75SH BN75SH PW EHN145SH EHN145SH PW EHN260SH-1 11,166 EHN260SH1-1 11,26 6PW EHN550SH-1 22,590 EHN550SH1-1 2,625 7PW EHN00SH-1 33,996 EHN00SH1-1 37,776 Overload Relay suffix code. Select from the Overload Relay Selection chart on back cover fold out page. Coil voltage selection chart Hz Contr. Volts Control transformers type / / / / A,B,EH F G 1 B 2 C A,B F EH N 1 J 3 M 5 DC A,B,EH Y W P Q R T For other voltages, consult factory. 24 & 4VAC coils are not available for sizes EH450 - EH00. For these applications, use an interposing control relay. Coil voltage selection All catalog numbers include a 120V coil. To select other coil voltages, substitute the code from the Coil Voltage Selection Chart for the first digit after the dash in the catalog number. D.C. operated starters If DC operation is required, consult factory. REDUCED VOLTAGE STARTERS: Selection: Circuit diagrams: Approximate dimensions: Open Enclosed Type A, B, EH Discount schedule PW PWE

9 Reduced voltage starters Part winding non-reversing NEMA 3R NEMA 12 NEMA 4 NEMA 4X (Outdoor Metal) (Metal Dustight) (Watertight) (Stainless Steel) Catalog List Catalog List Catalog List Catalog List number price number price number price number price UL rated B25SH3-1 $ 1914 B25SH2-1 $ 1914 B25SH4-1 $ 2034 B25SHX-1 $ 2425 B30SH B30SH B30SH B30SHX B40SH B40SH B40SH B40SHX B50SH B50SH B50SH B50SHX B63SH B63SH B63SH B63SHX B75SH B75SH B75SH B75SHX A110SH A110SH A110SH A110SHX EH145SH EH145SH EH145SH EH145SHX EH175SH EH175SH EH175SH4-1 EH175SHX EH210SH3-1 11,046 EH210SH2-1 11,046 EH210SH4-1 11,6 EH210SHX-1 12,700 EH260SH3-1 13,446 EH260SH2-1 13,446 EH260SH4-1 15,246 EH260SHX-1 17,400 EH300SH3-1 22,60 EH300SH2-1 22,60 EH300SH4-1 24,40 EH300SHX-1 26,150 EH450SH3-1 27,726 EH450SH2-1 27,726 EH450SH4-1 2,36 EH450SHX-1 30,175 EH550SH3-1 31,625 EH550SH2-1 31,625 EH550SH4-1 32,267 EH550SHX-1 33,275 EH700SH3-1 37,314 EH700SH2-1 37,314 EH700SH4-1 37,956 EH700SHX-1 39,600 EH00SH3-1 41,376 EH00SH2-1 41,376 EH00SH4-1 41,694 EH00SHX-1 44,100 NEMA rated BN25SH3-1 $ 1914 BN25SH2-1 $ 1914 BN25SH4-1 $ 2034 BN25SHX-1 $ 2425 BN50SH BN50SH BN50SH BN50SHX BN75SH BN75SH BN75SH BN75SHX EHN145SH EHN145SH EHN145SH EHN145SHX EHN260SH3-1 13,446 EHN260SH2-1 13,446 EHN260SH4-1 15,246 EHN260SHX-1 17,400 EHN550SH3-1 31,625 EHN550SH2-1 31,625 EHN550SH4-1 32,267 EHN550SHX-1 33,275 EHN00SH3-1 41,376 EHN00SH2-1 41,376 EHN00SH4-1 41,694 EHN00SHX-1 44,100 Overload Relay suffix code. Select from the Overload Relay Selection chart on back cover fold out page. REDUCED VOLTAGE STARTERS: Selection: Circuit diagrams: Approximate dimensions: Open Enclosed Type A, B, EH Discount schedule PW PWE.9

10 Circuit diagrams for reduced voltage starters Autotransformer & part winding Autotransformer An autotransformer starter reduces inrush current by using a transformer in the line just ahead of the motor to step down the voltage applied to the motor terminals. By reducing the voltage, the current drawn from the line is reduced during start-up. When the motor is up to speed and the setting time on the timer has expired, the autotransformer is bypassed. The 1S contactor drops out, the run contactor closes, and the 2S contactor opens, proving full voltage to the motor. The ABB autotransformer starter is a closed transition type meaning that the motor remains connected to the line during the entire acceleration period. The transformer has three taps which provide 50%, 65% and 0% of full line voltage. At delivery, the transformer is connected to the 65% tap; the inrush current will be reduced to 42% of normal; and the starting torque will be reduced to 42%. The autotransformer starter can be used for any squirrel-cage motor. Incoming Lines A B C Circuit Protective Device or Incoming Line Pad (if specified) CHFU CCT H1 H3 (if specified) CXFU XF 6 O L OTT L1 L1 L2 L2 L3 L RUN TR RUN RUN RUN 1S A1 A2 CR/TR 2S 2S 2S 2S 1S A1 A2 T1 T1 T2 T2 T3 T3 2S 100% 100% 2S A1 A2 0% SAT SAT 0% RUN IST ISCR 65% 65% 50% 50% L1 L2 A1 CR-1 A2 TR 1S 0% 1S 1S 0% Jumper T1 T A1 A2 RUN RUN L1 L A1 A2 OL T1 T2 T3 X1 CHFU H2 X2 Legend H4 Connect per voltage specified ISR Mechanical Interlock (if used) Run Contactor Incomplete Sequence Timer Incomplete Sequence Control Relay Starting Auto-Transformer Over-Temperature Thermostat (on SAT) Terminal Block Connection Point at Terminal Block Connection Point on Device with Number Part winding The part winding starter reduces inrush current by using two different sets of windings in the motor. Therefore, part winding starters can be used only with motors having stator windings divided into two equal parts with the terminals of each part available for external connection. The part winding starter consists of two across the line starters and a timer. The first starter is used to connect one winding of the motor across the line. The starting current from one winding will be about 50% of the starting current if both windings were connected. The starting torque is correspondingly 50%. Because the starting torque is so low and will not increase when only one winding is connected, the motor may not begin to accelerate. Therefore, the time delay for the second winding to be energized should not be more than 4 seconds. When the second wining is energized, the inrush current will increase depending upon the speed the motor has when the second winding is energized. Incoming Lines A B C Circuit Protective Device Busbar (if used) or Wire L1 L2 L3 1M 1OL Connect per CHFU CHFU voltage specified CCT (if specified) H1 H3 H2 H4 CXFU X2 6 1OL 2OL XF X L1 L2 L3 1M M A1 A2 CR TR CR A1 A2 2M TR 6 2OL 67 A1 A2 T7 T T9 To part-winding motor RUN- IST- ISR- SAT- OTT- TB CCT- Control Circuit Transformer CHFU- CCT Primaryary Fuse CXFU- CCT Secondary Fuse XF- Control Power Connection Point CR,CR1- Control Relays CT- Current Transformer TR- Timing Relay OL- Overload Relay 1S- Shorting Contactor 2S- Starting Contactor Legend CCT- Control Circuit Transformer CHFU- CCT Primary Fuse CXFU- CCT Secondary Fuse XF- Control Power Connection Point 1M- First Main Contactor 2M- Second Main Contactor CR- Control Relays (31) CT- Current Transformer OL- Overload Relay - Connection Point at Terminal Block 13- Connection Point on Device with Number REDUCED VOLTAGE STARTERS: Selection: Circuit diagrams: Approximate dimensions:

11 Circuit diagrams for reduced voltage starters Wye-delta Wye-delta, open transition The wye-delta open transition starter starts the motor by closing the S and 1M contactors which energize the windings in wye. The inrush current in wye is reduced to 33% of what it would be if the motor was started with an across the line starter. The starting time in wye is adjustable with a timer. After the elapsed time, the S contactor opens which closes the 2M contactor; there is a short period (about 50ms) when the motor is not energized; and then the motor runs full voltage in delta. A wye-delta starter requires a wye-delta wound motor with all six leads terminated outside the motor housing. Incoming Lines A B C Circuit Protective Device (if specified) L1 L2 L3 L1 L2 L3 L1 L2 L3 1M 2M S OL Bus Bar Mech. Intlk. T6 T4 T5 To Wye-Delta Motor CCT- CHFU- CXFU- XF- CR,CR1- CT- OL- PR- CHFU CCT H1 H3 (if specified) XF CXFU X1 Bus Bar CHFU H2 X2 H4 6 O L M TR S A1 A2 CR/TR Legend Control Circuit Transformer CCT Primaryary Fuse CCT Secondary Fuse Control Power Connection Point Control Relays Current Transformer Overload Relay Pilot Relay A1 A2 S S PR 43 1M A1 A2 1M TR- 1M - 2M- S- TB PR Connect per voltage specified A1 A2 2M A1 A1 A2 CR-1 A2 (If Used) Mechanical Interlock Timing Relay First Contactor Second Main Contactor Shorting Contactor Terminal Block Connection Point at Terminal Block Connection Point on Device with Number Wye-delta, closed transition The wye-delta closed transition starter works the same way as the open transition wye-delta starter except the closed transition version utilizes a set of resistors during the transition from start to run (wye to delta connection). These resistors eliminate the open circuit and prevent transient currents. Incoming Lines A B C CHFU CHFU Circuit CCT H1 H3 H2 H4 Protective Device (if specified) (if specified) XF CXFU X1 X2 6 O L IST Connect per voltage specified ISR ISR L1 L2 L3 L1 L2 L3 L1 L2 L3 S 1M 2M Mech. Intlk. OL Bus Bar 1 Bus Bar L1 L2 A1 A2 Jumper TR T 67 6 A1 A M T A1 S A2 CR/TR A1 A2 S S PR M A1 A2 1M Mechanical Interlock L1 L2 L3 T PR A1 A2 2M T6 T4 T5 To Wye-Delta Motor R E R R E E S S S A1 A2 CR-1 A1 A2 (If Used) Legend CCT- CHFU- CXFU- XF- CR,CR1- CT- OL- PR- TR- 1M - Control Circuit Transformer CCT Primaryary Fuse CCT Secondary Fuse Control Power Connection Point Control Relays Current Transformer Overload Relay Pilot Relay Timing Relay First Contactor Second Main Contactor Shorting Contactor Transition contactor Transition resistor ( s ) Incomplete sequence relay Incomplete sequence timer Terminal Block Connection Point at Terminal Block Connection Point on Device with Number REDUCED VOLTAGE STARTERS: Selection: Circuit diagrams: Approximate dimensions: M- S- T- RES- ISR- IST- TB

12 Approximate dimensions for reduced voltage starters Wye-delta, open w/cct Wye-delta, closed w/cct B C A Wye-delta, open transition Wye-delta closed transition B R X Stainless X Plastic B40 B R X Stainless X Plastic A95 & A R X Stainless EH R X Stainless EH175 EH X Stainless EH260 EH X Plastic EH450 EH R X Stainless EH700 EH R X Stainless B R X Stainless X Plastic B R X Stainless A95 & A X Stainless X Plastic EH X Stainless X Plastic EH R EH R EH R X Stainless EH R X Stainless X Plastic REDUCED VOLTAGE STARTERS: Selection: Circuit diagrams: Approximate dimensions:

13 Approximate dimensions for reduced voltage starters Wye-delta, open combination, non-fused Wye-delta, open combination, fused B C A Wye-delta, open transition,combination, non-fused B R X Stainless X Plastic Wye-delta, open transition,combination, fused B R X Stainless X Plastic B40 B R X Stainless X Plastic A95 & A EH EH175 EH EH260 EH R X Stainless X Plastic EH450 EH R X Stainless X Plastic EH700 EH B40 B R X Stainless X Plastic A95 & A EH EH175 EH EH260 EH R X Stainless EH450 EH EH700 EH REDUCED VOLTAGE STARTERS: Selection: Circuit diagrams: Approximate dimensions:

14 Approximate dimensions for reduced voltage starters Wye-delta, open combination, circuit breaker Wye-delta, closed combination, fused B C A Wye-delta, open transition, combination, circuit breaker B R X Stainless X Plastic Wye-delta, closed transition, combination, fused B R X Stainless X Plastic B40 B R X Stainless A95 & A R EH R EH175 EH R EH260 EH R X Stainless EH450 EH R X Stainless X Plastic EH700 EH R X Stainless X Plastic B40 B R X Stainless A95 & A R X Stainless EH R X Stainless EH175 EH R X Stainless EH260 EH R X Stainless X Plastic EH450 EH EH700 EH REDUCED VOLTAGE STARTERS: Selection: Circuit diagrams: Approximate dimensions:

15 Approximate dimensions for reduced voltage starters Wye-delta, closed combination, circuit breaker Part winding, combination, non-fused B C A Wye-delta, closed transition, combination, circuit-breaker Part winding, combination, non-fused B R X Stainless X Plastic B R X Stainless & A EH EH EH R X Stainless EH R X Stainless X Plastic EH B R X Stainless X Plastic B40 B R X Stainless X Plastic A95 & A R X Stainless X Plastic EH X Plastic EH175 EH R X Stainless X Plastic EH260 EH R X Stainless X Plastic EH450 EH R X Stainless X Plastic EH700 EH REDUCED VOLTAGE STARTERS: Selection: Circuit diagrams: Approximate dimensions:

16 Approximate dimensions for reduced voltage starters Part winding, combination, fused Part winding, combination, circuit breaker B C A Part winding, combination, fused Part winding combination, circuit breaker B R X Stainless X Plastic B R X Stainless X Plastic & A R X Stainless EH X Plastic EH X Plastic EH R X Stainless X Plastic EH EH B R X Stainless X Plastic B40 B R X Stainless X Plastic A95 & A R X Stainless X Plastic EH R X Stainless EH175 EH R X Stainless X Plastic EH260 EH X Plastic EH450 EH R X Stainless EH700 EH REDUCED VOLTAGE STARTERS: Selection: Circuit diagrams: Approximate dimensions:

17 Approximate dimensions for reduced voltage starters Part winding w/cct Autotransformer, combination, non-fused B C A Part winding w/cct B R X Stainless X Plastic Autotransformer, combination, non-fused B R X Stainless X Plastic B40 B R X Stainless X Plastic A95 & A R X Stainless X Plastic EH R X Stainless X Plastic EH175 EH R X Stainless EH260 EH R X Stainless EH450 EH X Stainless EH700 EH R X Stainless X Plastic B40 B R X Stainless X Plastic A95 & A EH EH175 EH EH260 EH R X Stainless X Plastic EH450 EH R X Stainless X Plastic EH700 EH REDUCED VOLTAGE STARTERS: Selection: Circuit diagrams: Approximate dimensions:

18 Approximate dimensions for reduced voltage starters Autotransformer, combination, fused Autotransformer, combination, circuit breaker B C A Autotransformer, combination, fused Autotransformer, combination, circuit breaker B R X Stainless X Plastic B R X Stainless A95 & A R X Stainless EH R X Stainless EH R X Stainless EH R X Stainless X Plastic EH EH B R X Stainless X Plastic B40 B R X Stainless A95 & A EH EH175 EH EH260 EH R X Stainless EH450 EH R X Stainless X Plastic EH700 EH REDUCED VOLTAGE STARTERS: Selection: Circuit diagrams: Approximate dimensions:

19 Approximate dimensions for reduced voltage starters Autotransformer w/cct B C A Autotransformer w/cct B R X Stainless X Plastic B R X Stainless A95 & A X Stainless X Plastic EH X Stainless X Plastic EH R EH R EH R X Stainless EH R X Stainless X Plastic REDUCED VOLTAGE STARTERS: Selection: Circuit diagrams: Approximate dimensions:

Smartstart Control Module

Smartstart Control Module Smartstart TECHNOLOGY What is Smartstart? The patented Smartstart control module is an integrated, seamless solution that incorporates operator control, superior motor protection, and automation system

More information

Controls Enclosed Non-Combination Starters - PESW Series

Controls Enclosed Non-Combination Starters - PESW Series NEMA 4/4X Non Metallic Enclosure Product Features WEG offers non-reversing and non-combination NEMA-4X magnetic starter up to 75HP at 460V. Featuring components that meet IEC design standards and UL horsepower

More information

Jockey Pump Controllers

Jockey Pump Controllers BR081001EN Microprocessor Based with Color Touchscreen Product Description ACROSS THE LINE Controllers operate across-the-line. Full voltage is applied to the motor for starting by the use of a single

More information

Jockey Pump Controllers

Jockey Pump Controllers BR081001EN Microprocessor Based with Color Touchscreen Product Description ACROSS THE LINE Controllers operate across-the-line. Full voltage is applied to the motor for starting by the use of a single

More information

SMARTSTART MOTOR STARTERS

SMARTSTART MOTOR STARTERS SMARTSTART MOTOR STARTERS MCG WWW.MCG-USA.COM 1 AT A GLANCE Covers all line voltages from 200-600V AC, single or three phase Transformer supplies a 24V AC coil voltage, no matter the line voltage 12V AC/DC

More information

Medium Voltage Metal-Enclosed Power Capacitor Banks

Medium Voltage Metal-Enclosed Power Capacitor Banks 66 Carey Road Queensbury, NY 12804 Ph: (518) 792-4776 Fax: (518) 792-5767 www.nepsi.com sales@nepsi.com Medium Voltage Metal-Enclosed Power Capacitor Banks General Northeast Power System s (NEPSI's) medium

More information

9/7/2010. Chapter , The McGraw-Hill Companies, Inc. MOTOR SYMBOLS. 2010, The McGraw-Hill Companies, Inc.

9/7/2010. Chapter , The McGraw-Hill Companies, Inc. MOTOR SYMBOLS. 2010, The McGraw-Hill Companies, Inc. Chapter 2 MOTOR SYMBOLS 1 Symbols are used to represent the different components of a motor control system. Symbols sometimes look nothing like the real thing, so we have to learn what the symbols mean.

More information

IPS INTELLIGENT PUMP STARTER

IPS INTELLIGENT PUMP STARTER IPS INTELLIGENT PUMP STARTER The IPS Intelligent Pump Starter features SMARTSTART motor protection, integrated electronic pump protection overload, and power metering and data logging options. Ø & Ø, 0/60

More information

Control Transformers Control transformers

Control Transformers Control transformers Control Transformers It is often desirable to operate the control circuit at a lower voltage than the power circuit. Control transformers are used to step a voltage down to a lower level. Siemens Class

More information

The City of Winnipeg Dry Type Transformers up to 600 V Primary Section Bid Opportunity No Page 1 of 2

The City of Winnipeg Dry Type Transformers up to 600 V Primary Section Bid Opportunity No Page 1 of 2 The City of Winnipeg Dry Type Transformers up to 600 V Primary Section 26121601 Bid Opportunity No. 1196-2014 Page 1 of 2 Part 1 General 1.1 RELATED REQUIREMENTS.1 Section 26 05 01 - Common Work Results

More information

Medium Voltage Metal-Enclosed Harmonic Filter Systems

Medium Voltage Metal-Enclosed Harmonic Filter Systems 66 Carey Road Queensbury, NY 12804 Ph: (518) 792-4776 Fax: (518) 792-5767 www.nepsi.com sales@nepsi.com Medium Voltage Metal-Enclosed Harmonic Filter Systems General NEPSI s armorvar, medium voltage metal-enclosed

More information

Enclosed Non-Reversing Combination Controller, AC Operation - Type 1/12K/IP66 ➏➐. Non-Metallic Type 1/12K/IP66 Enclosure (KS7-C0C4R)

Enclosed Non-Reversing Combination Controller, AC Operation - Type 1/12K/IP66 ➏➐. Non-Metallic Type 1/12K/IP66 Enclosure (KS7-C0C4R) KWIKstarter/CX7 CX7 Non-Reversing Combination Controller, AC Enclosed Non-Reversing Combination Controller, AC Operation - Type 1/12K/IP66 ➏➐ Catalog Number ➍➏➑➒ ~ ~ ~ ~ 0.10 0.16 2.1 1 CX7-9-10- -AS0.16A-A10-PG

More information

Series CA7 Contactors

Series CA7 Contactors Series Rugged, space saving and modular Sprecher + Schuh s newest contactor for applications up to 6HP Over years of design experience has produced Sprecher + Schuh s seventh generation contactor line.

More information

1510 MOTOR CONTROLLERS

1510 MOTOR CONTROLLERS SECTION 262913- MOTOR CONTROLLERS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of contract, including general and supplementary conditions and Division 1 specification section,

More information

Quantum III. Compact DC Drive Package. Slitter DC Drive Package. Quantum III

Quantum III. Compact DC Drive Package. Slitter DC Drive Package. Quantum III Compact DC Drive Package The delivers a DC drive package that integrates the intelligence of the Mentor II with a space saving design that incorporates many accessories typically required in the North

More information

Series CA9 Contactors

Series CA9 Contactors Series C9 Contactors Sprecher + Schuh s C9 contactor line combines the simple function of our popular C7 series with the rugged performance demanded in this wide horsepower range. C9 contactors offer a

More information

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS SECTION 262816 - ENCLOSED SWITCHES AND CIRCUIT BREAKERS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division

More information

IMS Control & EPR, We keep your motors running ABB s new control & protection devices up to 18.5 kw / 20 hp

IMS Control & EPR, We keep your motors running ABB s new control & protection devices up to 18.5 kw / 20 hp IMS Control & EPR, 2010 01 29 We keep your motors running ABB s new control & protection devices up to 18.5 kw / 20 hp October 27, 2010 1SBC101089D0201 ABB s new control and protection devices Up to 18.5

More information

FTA1350 WYE-DELTA CLOSED FIRE PUMP CONTROLLERS STANDARD SUBMITTAL PACKAGE

FTA1350 WYE-DELTA CLOSED FIRE PUMP CONTROLLERS STANDARD SUBMITTAL PACKAGE FTA1350 WYE-DELTA CLOSED FIRE PUMP CONTROLLERS STANDARD SUBMITTAL PACKAGE NOTE: The drawings included herein are for standard controllers. Actual "as built" drawings may differ from those seen here. ASCO

More information

Ethernet Port The on-board Ethernet port is used for direct connection to a computer for data transfer.

Ethernet Port The on-board Ethernet port is used for direct connection to a computer for data transfer. LMR PLUS Ethernet Port The on-board Ethernet port is used for direct connection to a computer for data transfer. RS485 Serial Port An RS485 serial port is provided for communication to various external

More information

K-Line Mini - Contactors, Overload Relays and Accessories

K-Line Mini - Contactors, Overload Relays and Accessories K-Line Mini - Contactors, Overload Relays and Accessories Class 8502 CONTENTS Description...................................................... Page General Information...............................................

More information

Metering Devices, Protective Relays, Software and Connectivity. Pre-Wired Control Power, Voltage and CT Inputs

Metering Devices, Protective Relays, Software and Connectivity. Pre-Wired Control Power, Voltage and CT Inputs .3 Features and Benefits Saves installation time and cost One part number to order; no need to worry that any part has been left out Pick the meter or meters you need as it is designed to fit various Eaton

More information

OVERLOAD RELAYS POWER & ACTUATION PROVEN. series

OVERLOAD RELAYS POWER & ACTUATION PROVEN. series POWER & ACTUATION OVERLOAD RELAYS series Need reliable, accurate overload and phase-loss protection for your motors? c3controls Series Bimetallic Overload Relays provide unmatched protection and can be

More information

Enclosed Non-Reversing Combination Controller, AC Operation - Type 1/12K/IP66 ➏➐ (KS7-C0C4R) Discount Schedule F-1

Enclosed Non-Reversing Combination Controller, AC Operation - Type 1/12K/IP66 ➏➐ (KS7-C0C4R) Discount Schedule F-1 KWIKstarter/CX7 CX7 Non-Reversing Combination Controller, AC Enclosed Non-Reversing Combination Controller, AC Operation - Type 1/12K/IP66 ➏➐ ~ ~ ~ ~ 0.10 0.16 2.1 1 CX7-9-10- -AS0.16A-A10-PG 551 Q4 ~

More information

Motor Control Products Selection Guide

Motor Control Products Selection Guide MKING MODERN LIVING POSSIBLE Motor Control Products Selection Guide Contactors, Relays, and Circuit Breakers www.danfoss.com/ia c o n t e n t s Minicontactors CI 5 Thermal Overload Relays TI 9C for Minicontactors

More information

TECHNICAL BROCHURE BCPNEMAST R0. NEMA Rated Three-Phase Starters BY EATON

TECHNICAL BROCHURE BCPNEMAST R0. NEMA Rated Three-Phase Starters BY EATON TECHNICAL BROCHURE BCPNEMAST R0 NEMA Rated Three-Phase Starters BY EATON STANDARD FEATURES Series ECN - NEMA Rated Three-Phase Starters Adjustable Electronic Overloads C440 Series - Adjustable Class, Bi-metallic,

More information

LANDSCAPE TRANSFORMERS

LANDSCAPE TRANSFORMERS LANDSCAPE TRANSFORMERS Precision Power. Perfect Light. Remote Transformers Linear Fluorescents Sign Ballasts Electronic HID LED Drivers Landscape Transformers Hatch Landscape Transformers have been designed

More information

SECTION VARIABLE FREQUENCY DRIVES

SECTION VARIABLE FREQUENCY DRIVES PART 1 GENERAL 1.01 DESCRIPTION This specification section establishes the requirements for variable frequency motor drives. The associated motor(s) shall be specified separate from the drive and listed

More information

JK Series POWER DISTRIBUTION. Solid State Starters Medium Voltage A

JK Series POWER DISTRIBUTION. Solid State Starters Medium Voltage A POWER DISTRIBUTION JK Series Solid State Starters Medium Voltage 200-400-600-720A SOLID STATE STARTER JKSSS4+ Series The JKSSS Series of motor starter is the result of extensive research and development.

More information

Contactors and Contactor Assemblies

Contactors and Contactor Assemblies Contactor Industrial Controls Product Catalog 07 Section c o n t e n t s Section Overview / - /5 Product Overview /6 - /7 Contactors 3RT0, 3-pole to 95 /8 3RT0, 3-pole to 500 /9 3RT, 3-pole Vacuum to 500

More information

Series CA7 Contactors

Series CA7 Contactors C7 Series C7 Rugged, space saving and modular Sprecher + Schuh s newest contactor for applications up to 6HP Over years of design experience has produced Sprecher + Schuh s seventh generation contactor

More information

Micro Contactor MA Series

Micro Contactor MA Series Relay-sized contactor, making it the world s smallest >3mm contact clearance acc. to IEC 60335-1 for Safety Applications Reversing contactor with mechanical interlock 3 Pole and 1 Aux. Contact NO or NC

More information

General Purpose Control Components Welcome to the Control Catalog!

General Purpose Control Components Welcome to the Control Catalog! Welcome to the Control Catalog! This new edition is your comprehensive guide to product selection and pricing for GE electrical control products. Our new format in this latest edition allows for maximum

More information

Enclosed DOL Motor Starter Type 4x, Plastic, 3-Phase

Enclosed DOL Motor Starter Type 4x, Plastic, 3-Phase Enclosed DOL Starter Type x, Plastic, Phase C US LISTED ENCLOSED INDUSTRIAL CONTROL PANEL WIRING SPECIFICATIONS CONTROL/COIL VOLTAGE: LINE (LINE) START/STOP (STSR) START STOP //8 //8 Customer Supplied

More information

Overload Relays 3RU Thermal Overload Relays 3RB Solid State Overload Relays 3UF SIMOCODE pro Intelligent Motor Protection

Overload Relays 3RU Thermal Overload Relays 3RB Solid State Overload Relays 3UF SIMOCODE pro Intelligent Motor Protection IEC Power Control Product Overview Alphabetical Product and Catalog Number Index MSPs 3RV20 Motor Starter Protectors 3RV27 & 3RV28 Circuit Breakers 3RA19/29 & 3RV19/29 Accessories 1 Contactors 3RT, 3TF,

More information

Table 1. IEC Power Control Devices. Type Description Cost Electrical Operations. Soft starters or drives that gradually start and stop motors.

Table 1. IEC Power Control Devices. Type Description Cost Electrical Operations. Soft starters or drives that gradually start and stop motors. IEC Power Control Devices Training Manual XT Training Module New Information March 08 Contents Description Page Overview..................... Contactors................... Overload Relays (Bimetal).......

More information

IEC Power Control Contactors and Contactor Assemblies

IEC Power Control Contactors and Contactor Assemblies IEC Power Control Contactors and Contactor ssemblies Contents Pages Contents Pages Section Overview......................... / - /5 Product Overview......................... /6 - /7 Contactors 3RT0 / 3RT0,

More information

GE Power Management. MMII Intelligent MCC Controller

GE Power Management. MMII Intelligent MCC Controller A concept that will offer reduced overall installed cost and production efficiency through information availability to operators and maintenance. Presentation Overview 6 Applications 6 Protection and Control

More information

Heater Elements Starters with eutectic alloy overload relays require 3 heater elements. Located on page Max. Hp Rating Fuse Clip Type 3R/4/12

Heater Elements Starters with eutectic alloy overload relays require 3 heater elements. Located on page Max. Hp Rating Fuse Clip Type 3R/4/12 Bulletin NEM Combination Reversing Starters Product Selection Disconnect Type (Fusible with Class R Fuse Clips) (Non-Fusible) Bulletin NEM starter sizes Overload relays: Eutectic supplied as standard,

More information

Vector Drive - Troubleshooting Guide

Vector Drive - Troubleshooting Guide Haas Technical Documentation Vector Drive - Troubleshooting Guide Scan code to get the latest version of this document Translation Available The Haas Vector drive is the source of power for the spindle

More information

SECTION SOLID-STATE REDUCED VOLTAGE STARTERS

SECTION SOLID-STATE REDUCED VOLTAGE STARTERS SECTION 26 29 13.16 PART 1 - GENERAL 1.1 THE REQUIREMENT A. General: The CONTRACTOR shall provide solid-state reduced voltage motor starters, complete and operable, in accordance with the Contract Documents.

More information

Crane Control Contactors and Relays

Crane Control Contactors and Relays October 8 DC Relays Type KC Heavy-Duty Mill 75 Contact Conversion The fully visible contacts have NEMA ICS--5 heavy-duty interrupting ratings and are easily converted in the field using just a screwdriver

More information

5.1. Motor Protection and Monitoring. Contents. Product Overview. Monitoring Relays. D64R Series Digital Ground Fault Relays...

5.1. Motor Protection and Monitoring. Contents. Product Overview. Monitoring Relays. D64R Series Digital Ground Fault Relays... .1 Ground Fault Relays and Monitors Contents Description Current.................. Phase................... Voltage.................. Ground Fault Relays and Monitors D64R Series Digital Ground Fault Relays....

More information

MODELS DPDT DPDT DPDT-60MS DPDT-60MS

MODELS DPDT DPDT DPDT-60MS DPDT-60MS INSTALLATION INSTRUCTIONS Revision B1 Rapid City, SD, USA, 03/2010 MODELS 201-100-DPDT 201-200-DPDT 201-100-DPDT-60MS 201-200-DPDT-60MS II_201-XXX-DPDT_B1 II-201-DPDT-B BE SURE POWER IS DISCONNECTED PRIOR

More information

Crane Control Class 9004

Crane Control Class 9004 Catalog 17 CONTENTS Description.....................................................Page Pricing and Ordering Information...................................... 140 Dimensions and Weights............................................

More information

Standard Options. Model 4100 Position Indicating Meter. Three Phase Motor Control. Positran Transmitter

Standard Options. Model 4100 Position Indicating Meter. Three Phase Motor Control. Positran Transmitter Standard Options Model 4100 Position Indicating Meter A percent-of-full-travel meter is supplied with a trim potentiometer resistor, terminal block and connectors. A potentiometer is required in the actuator

More information

78 Series Electromechanical Relay Selection Guide

78 Series Electromechanical Relay Selection Guide 78 Series Electromechanical Relay Selection Guide Specification 781 Series 782 Series 783 Series 784 Series Coil Voltages Configuration SPDT DPDT 3PDT 4PDT Contact Rating 15A 15A 15A 15A Base Socket 5

More information

1.1. Contactors and Starters... Contents Description Relays and Timers... Miniature Controls... Manual Motor Protectors. XT IEC Power Control

1.1. Contactors and Starters... Contents Description Relays and Timers... Miniature Controls... Manual Motor Protectors. XT IEC Power Control . Contents Description Relays and Timers......................... Miniature Controls......................... Contactors and Starters.................... Thermal Overload Relays.................... C440/XT

More information

Application Techniques CENTERLINE 2100 Motor Control Centers

Application Techniques CENTERLINE 2100 Motor Control Centers POWER SYSTEM CONSIDERATIONS FOR PRODUCT SELECTION Application Techniques CENTERLINE 2100 Motor Control Centers Power System Considerations for Product Selection i Power System Considerations for Product

More information

MSR Level Control Relay Module Operating Instructions for Level Control Relay Module Model: MSR

MSR Level Control Relay Module Operating Instructions for Level Control Relay Module Model: MSR Operating Instructions for Level Control Relay Module Model: MSR MSR Operation Instructions Rev. Apr 07 Page 1/8 1. Note Please read and take note of these operating instructions before unpacking and commissioning.

More information

SECTION DISCONNECT SWITCHES

SECTION DISCONNECT SWITCHES SECTION 16440 DISCONNECT SWITCHES PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and other Division 01 Specification

More information

Series SD-3PB Digital THERMOSTAT + TIMER

Series SD-3PB Digital THERMOSTAT + TIMER SD-3PB Thermostat and Interval Timer in one Unit. This microcomputer based controller consists of two sections: The Digital Timer and Digital Thermostat, working together to control the power switched

More information

3RT, 3TB, 3TF Contactors for Switching Motors

3RT, 3TB, 3TF Contactors for Switching Motors RT, TB, TF Contactors for Switching Motors Overview RT contactors and coupling relays Size S00 with mountable accessories The SIRIUS generation of controls is a complete, modular system family, logically

More information

920 Remote Control (RC) Switches

920 Remote Control (RC) Switches 920 Remote Control (RC) Switches ASCO is the global leader in power switching and controls ASCO 920 PRODUCT SPECIFICATIONS SWITCH ONLY (PANELBOARD MOUNTING) 1,2,3 () DIMENSIONS, IN.(MM) WIDTH HEIGHT DEPTH

More information

D64RP18 INSTRUCTION MANUAL N.O. N.C V AC/DC TEST/ RESET

D64RP18 INSTRUCTION MANUAL N.O. N.C V AC/DC TEST/ RESET D64RP18 INSTRUCTION MANUAL N.O. N.O. CONTROL CIRCUIT N.C. N.C. CONTROL CIRCUIT 24-240V AC/DC L POWER SUPPLY N TEST/ RESET TEST/RESET PUSHBUTTON CT Wires EXTERNAL CORE BALANCE CT RATINGS PER IEC 60755 CT

More information

Starters. Power. Manual Motor Low Voltage Starters 600, 609, 609U, 609TU. 600 Manual Starting Switches 609 Manual Starting Switches

Starters. Power. Manual Motor Low Voltage Starters 600, 609, 609U, 609TU. 600 Manual Starting Switches 609 Manual Starting Switches Starters Manual Motor Low Voltage Starters 600, 609, 609U, 609TU Compact design Undervoltage protection Manual operation with overload protection Ideal for low HP applications, up to 10 HP three phase

More information

Single-Phase Encapsulated

Single-Phase Encapsulated Single-Phase Encapsulated 7 50 VA to 25 kva Applications n For general loads, indoors or out, including lighting, industrial and commercial applications n Units may be banked for 3-Phase operations n For

More information

ABB Industrial Systems Inc. Standard Drives. ACH500-06E Effective 6/1/95

ABB Industrial Systems Inc. Standard Drives. ACH500-06E Effective 6/1/95 Part 1 - GENERAL ASEA BROWN BOVERI ABB Industrial Systems Inc. Standard Drives ACH500-06E Effective 6/1/95 Sample Specification for Adjustable Frequency Drives (2 to 400 HP) for Variable Torque Applications

More information

The PCI Series. Precise power control for complex SCR applications. Phase Angle Fired SCR Power Controls AMPS VAC

The PCI Series. Precise power control for complex SCR applications. Phase Angle Fired SCR Power Controls AMPS VAC The PCI Series Phase Angle Fired SCR Power Controls 25-1200 AMPS 120-600 VAC Precise power control for complex SCR applications. ROBICON 1996 Distributed Worldwide by www.mcgoff-bethune.com Applications

More information

29 $ Manual Motor Starters FREESHIPPING. MOTOR CONTROLS 25. Features: MMS-32H Frame. MMS-63H Frame.

29 $ Manual Motor Starters FREESHIPPING.  MOTOR CONTROLS 25. Features: MMS-32H Frame. MMS-63H Frame. www.factorymation.com/motorcontrols MOTOR CONTROLS 25 Manual Motor Starters High interrupt capacity Din rail and surface mounting Lockable handle (OFF position) IP20 finger safe terminals Class 10 thermal

More information

Table of Contents 1. Overview Installation...6

Table of Contents 1. Overview Installation...6 (2003-01-31) Table of Contents 1. Overview...1 1.1. Introduction... 1 1.2. Product Description... 1 1.2.1. Mechanical Actuator Assembly with M2CP Electrical Enclosure... 1 1.2.2. Variable Frequency Controller

More information

Mini Contactors. Mini Contactor Relays 4-pole 20 Auxiliary Contact Blocks. Interface Contactor Relays. Mini Contactors 22 Auxiliary Contact Blocks

Mini Contactors. Mini Contactor Relays 4-pole 20 Auxiliary Contact Blocks. Interface Contactor Relays. Mini Contactors 22 Auxiliary Contact Blocks Mini Contactors Mini Contactor Relays 4-pole 20 Auxiliary Contact Blocks Interface Contactor Relays Mini Contactors 22 Auxiliary Contact Blocks Mini Contactors With Fast On Tab Connectors 24 Mini Contactors

More information

Set up and verify the operation of basic motor starters. Understand the purpose of a separate control circuit.

Set up and verify the operation of basic motor starters. Understand the purpose of a separate control circuit. Exercise 3-1 Motor Starters EXERCISE OBJECTIVE Set up and verify the operation of basic motor starters. Understand the purpose of a separate control circuit. DISCUSSION OUTLINE The Discussion of this exercise

More information

NC2 Contactor, 115~630A. 1. General. 2. Type Designation. 3. Terminal Connection. Cabling(Cu) Cable 2. Tightening torque (N m) Screw size

NC2 Contactor, 115~630A. 1. General. 2. Type Designation. 3. Terminal Connection. Cabling(Cu) Cable 2. Tightening torque (N m) Screw size R C US LISTED EU Germany Czech Ukrain South Africa USA NC Contactor, 5~30A. General. Certificates: CE, VDE, ESC, UKRTEST, RCC, UL.. Electric ratings; AC50/0Hz, up to 000V, up to 30A;.3 Application: remote

More information

XT IEC Power Control Contactors, Starters and Overload Relays

XT IEC Power Control Contactors, Starters and Overload Relays May 00 Product Family Overview 9 Contents Features and Benefits Description Page Contactors and Starters Catalog Number Selection................. Non-reversing Contactors.... Reversing Contactors........

More information

Magnetically Actuated Safety Interlock Switches

Magnetically Actuated Safety Interlock Switches Conforms to EN10, EN292, EN020-1 CSA and BG approved Actual Size Magnetically Actuated Safety Interlock Switches Large selection choose from a large selection of contact configurations housed in plastic,

More information

Wiring Diagrams DIAGRAM INDEX. POWER SCHEMATICS Unit 30GXN,R Voltage Figure Number

Wiring Diagrams DIAGRAM INDEX. POWER SCHEMATICS Unit 30GXN,R Voltage Figure Number 30GXN,R Sizes 080-528 Air-Cooled Chillers with ComfortLink Controls 50/60 Hz Wiring Diagrams DIAGRAM INDEX POWER SCHEMATICS Unit 30GXN,R Voltage Figure Number Label Diagram No. 30GX 080-178* ALL 1 505429

More information

ASCO 920 Remote Control (RC) Switches

ASCO 920 Remote Control (RC) Switches Maximum reliability and excellent value ASCO 920 Remote Control (RC) Switches ASCO 920 Remote Control Switch in Type Enclosure The ASCO 920 is designed as a feeder disconnect switch for load capacities

More information

PanelFAST. Setting a new standard for immediate product availability with Square D Ready to Install (RTI) Panelboards

PanelFAST. Setting a new standard for immediate product availability with Square D Ready to Install (RTI) Panelboards PanelFAST Setting a new standard for immediate product availability with Square D Ready to Install (RTI) Panelboards Whether you planned ahead or have an unexpected project, why wait? You should expect

More information

Product Description. Table of Contents

Product Description. Table of Contents Product Providing users with easy installation in mechanical fan and pump systems, the Allen-Bradley PowerFlex 400 AC drive offers a wide range of built-in features allowing for seamless building system

More information

Close Protection from Moeller. miniature branch circuit breakers miniature supplementary protectors

Close Protection from Moeller. miniature branch circuit breakers miniature supplementary protectors Close Protection from Moeller miniature branch circuit breakers miniature supplementary protectors FAZ branch circuit breakers General Information... Selection Tables Trip Characteristic C - Box terminals...

More information

160 AA02SF1 AF DS-D17

160 AA02SF1 AF DS-D17 Ordering Instructions The Standard Packaged Drive Program allows users to create drive packages based on their specific needs. A complete drive package may be specified by assembling a single catalog number

More information

IEC Contactors. Auxiliary Contact Blocks GENERAL

IEC Contactors. Auxiliary Contact Blocks GENERAL IEC Contactors Auxiliary Contact Blocks GENERAL Description 3RH19 Auxiliary contact blocks The 3RH19 auxiliary contact blocks are available in 1, 2, 3 and 4-pole front mount versions and 2-pole side mount

More information

New Solutions. for AC Motor Starters

New Solutions. for AC Motor Starters ADAPTABILITY RELIABILITY CREATIVITY New Solutions for AC Motor Starters Featuring : Electronic Centrifugal Switches for Capacitor Start (Capacitor Run) Motors / Digital Motor Starters for Three Phase Bidirectional

More information

ICM 400. Three Phase Voltage Monitor with Reset Switch. Low cost line voltage protection for 3-phase motor systems

ICM 400. Three Phase Voltage Monitor with Reset Switch. Low cost line voltage protection for 3-phase motor systems ICM 400 Three Phase Voltage Monitor with Reset Switch Low cost line voltage protection for 3-phase motor systems 3-Position Reset Switch: MAN-MAN AUTO-AUTO AUTO-MAN Installation, Operation & Application

More information

Large Frame IEC Contactors

Large Frame IEC Contactors Large Frame IEC Contactors Bulletin 100-E PUBLIC Copyright 2017 Rockwell Automation, Inc. All Rights Reserved. 1 Changing Applications for Contactors There are fewer and fewer traditional large motor starting

More information

3 Pole Contactors with AC operating coils

3 Pole Contactors with AC operating coils 1 3 Pole Contactors with AC operating coils Characteristics General Characteristics Switching Current 9A ~ Rated insulation voltage (Ui) (Conforming to IEC 158-1) V 750 IEC 60947-4 V 1000 Conforming to

More information

Series 300 POWER TRANSFER SWITCHES MAXIMUM RELIABILITY & EXCELLENT VALUE FEATURES

Series 300 POWER TRANSFER SWITCHES MAXIMUM RELIABILITY & EXCELLENT VALUE FEATURES Series 300 POWER TRANSFER SWITCHES MAXIMUM RELIABILITY & EXCELLENT VALUE With a Series 300 Transfer Switch, you get a product backed by ASCO Power Technologies, the industry leader responsible for virtually

More information

ECET 211 Electric Machines & Controls Lecture 6 Contactors and Motor Starters (1 of 2) Lecture 6 Contactors and Motor Starters

ECET 211 Electric Machines & Controls Lecture 6 Contactors and Motor Starters (1 of 2) Lecture 6 Contactors and Motor Starters ECET 211 Electric Machines & Controls Lecture 6 Contactors and Motor Starters (1 of 2) Text Book: Chapter 6, Electric Motors and Control Systems, by Frank D. Petruzella, published by McGraw Hill, 2015

More information

SECTION MEDIUM VOLTAGE MOTOR CONTROLLERS LIMITAMP WITH POWER MANAGEMENT. A. Medium Voltage Motor Controllers with Power Management

SECTION MEDIUM VOLTAGE MOTOR CONTROLLERS LIMITAMP WITH POWER MANAGEMENT. A. Medium Voltage Motor Controllers with Power Management PART 1 GENERAL A. The requirements of the Contract, Division 1, and Division 16 apply to work in this Section. 1.01 SECTION INCLUDES A. Medium Voltage Motor Controllers with Power Management 1.02 RELATED

More information

RW-E. Overloads. Solid-State Overload Relays. Standard Features

RW-E. Overloads. Solid-State Overload Relays. Standard Features RW-E The new RW_E Solid State Overload relays are developed with cutting edge technology according to the most demanding standards worldwide. With its wide current/mp setting; the RW_E OL Relay can be

More information

SECTION PANELBOARDS. A. NECA (National Electrical Contractors Association) -Standard of Installation

SECTION PANELBOARDS. A. NECA (National Electrical Contractors Association) -Standard of Installation SECTION 26 24 16 PANELBOARDS PART 1 -GENERAL 1.1 SUMMARY A. Section includes distribution and branch circuit panelboards, electronic grade branch circuit panelboards, [and load centers]. 1.2 REFERENCES

More information

3.7. Control Relays and Timers.

3.7. Control Relays and Timers. Control Relays and Timers.7 BF/BFD Series Fixed Contact Industrial Control Contents D15 Series Freedom 600V Multipole.......... BF/BFD Series Fixed Contact Industrial Control Product Selection.......................

More information

3.7. Control Relays and Timers. Contents. BF/BFD Series Fixed Contact Industrial Control. Machine Tool Relays. Product Description

3.7. Control Relays and Timers. Contents. BF/BFD Series Fixed Contact Industrial Control. Machine Tool Relays. Product Description Control Relays and Timers.7 BF/BFD Series Fixed Contact Industrial Control Contents D15 Series Freedom 600V Multipole.......... BF/BFD Series Fixed Contact Industrial Control Product Selection.......................

More information

Standard SureVolt Power Conditioner / Voltage Regulator

Standard SureVolt Power Conditioner / Voltage Regulator Utility Systems Technologies, Inc. P.O. Box 110 Latham, NY 12110 Standard SureVolt Power Conditioner / Voltage Regulator Introduction The SureVolt electronic voltage regulator / power conditioner provides

More information

Magnetic Circuit Protectors 153. Multi-Pole Circuit Protectors 154. APL/UPL, 205/295 Barriers 155. Configurations 156. Operating Characteristics 158

Magnetic Circuit Protectors 153. Multi-Pole Circuit Protectors 154. APL/UPL, 205/295 Barriers 155. Configurations 156. Operating Characteristics 158 Magnetic Circuit Protectors 53 Multi-Pole Circuit Protectors 54 APL/UPL, 205/295 Barriers 55 Configurations 56 Operating Characteristics 58 Delay Curves 59 Specifications 64 APL/UPL Decision Tables 70

More information

Rated operational Control Voltage Uc Supply Voltage Connection Rated operational current 40 C voltage Ue Us 25A AC-53a 32A AC-53a

Rated operational Control Voltage Uc Supply Voltage Connection Rated operational current 40 C voltage Ue Us 25A AC-53a 32A AC-53a otor Controllers AC Semiconductor otor Controller Type RSHR 3-Phase Soft starting and stopping of 3-phase squirrel cage motors Control of all 3 phases In Line or In Delta motor connection Low inrush and

More information

PowerFlex 400 AC Drive Guide Specification

PowerFlex 400 AC Drive Guide Specification PowerFlex 400 AC Drive Guide Specification Adjustable Frequency Drives with Bypass 3.0 50HP @ 208V AC 3.0 350HP @ 480V AC PART 1 GENERAL 1.01 Quality Assurance A. The manufacturer shall have minimum 5

More information

SOUTH VALLEY WATER RECLAMATION FACILITY MISCELLANEOUS ELECTRICAL UPGRADES TABLE OF CONTENTS DIVISION 16 - ELECTRICAL

SOUTH VALLEY WATER RECLAMATION FACILITY MISCELLANEOUS ELECTRICAL UPGRADES TABLE OF CONTENTS DIVISION 16 - ELECTRICAL SOUTH VALLEY WATER RECLAMATION FACILITY MISCELLANEOUS ELECTRICAL UPGRADES TABLE OF CONTENTS DIVISION 16 - ELECTRICAL SECTION NO. TITLE 16262 VARIABLE FREQUENCY DRIVES 0.50 50 HORSEPOWER 16264 VARIABLE

More information

EMS 1Ø, 120 ~ 230V, 1/10-25HP 3Ø, 200 ~ 600V, 1/2-300HP

EMS 1Ø, 120 ~ 230V, 1/10-25HP 3Ø, 200 ~ 600V, 1/2-300HP ES, 120 ~ 230V, 1/10-25HP, 200 ~ 600V, 1/2-300HP ENERGY ANAGEENT STARTER T Smartstart THE OST INTELLIGENT STARTER YET Power metering, optional BACnet or odbus communications, and an intuitive interface

More information

.2 Section General Commissioning (Cx) Requirements. .3 Section Common Work Requirements - Electrical

.2 Section General Commissioning (Cx) Requirements. .3 Section Common Work Requirements - Electrical Issued for Review Section 26 28 16.01 Air Circuit Breakers Page 1 of 7 PART 1 GENERAL 1.1 GENERAL.1 This specification serves to define requirements for a replacement of low voltage circuit breaker of

More information

194E FA 32 E P11 P11 6

194E FA 32 E P11 P11 6 Bulletin E IEC Load Switches, A Product Selection/Catalog Number Explanation Bulletin E Enclosed Disconnect Load Switches with R Handles (with Defeater, suitable for padlocks) E-FA Painted Steel Enclosure

More information

Contactors and Contactor Assemblies

Contactors and Contactor Assemblies RT contactors, size S00 The product range at a glance The new generation is a complete, modular system family, logically designed right down to the last detail, from the basic units to the accessories.

More information

INTEGRATED AUTOMATION ACTUATORS AND OPERATORS

INTEGRATED AUTOMATION ACTUATORS AND OPERATORS 25 34 13.13 - PART 1 - GENERAL 1.1 THE REQUIREMENT A. The CONTRACTOR shall provide complete Valve Actuators and Operators as shown on the drawings, control diagrams, herein, or in other Sections of the

More information

ELECTRICAL CONTROL SYSTEM COMPONENTS

ELECTRICAL CONTROL SYSTEM COMPONENTS Module - 2 ELECTRICAL CONTROL SYSTEM COMPONENTS Lecture - 1 MECHANICAL SWITCHES Shameer A Koya EEET 221 : Electrical Control Systems. Module 2 - Objectives State the functions of control system components

More information

FAZ Supplementary Protectors, FAZ Miniature Circuit Breakers, P2 Disconnect Switches Overview

FAZ Supplementary Protectors, FAZ Miniature Circuit Breakers, P2 Disconnect Switches Overview FAZ Supplementary Protectors, FAZ Miniature Circuit Breakers, P2 Disconnect Switches Overview Supplementary Protectors / Miniature Circuit Breakers Page System overview 10/003 10/001 Supplementary protectors

More information

Mini Contactors & Overloads

Mini Contactors & Overloads 108 Mini s & Overloads GMC-12M Surface or DIN rail mountable UL508 compliant 1/ to 7-1/ 50/60Hz AC and DC versions available Direct-mounting overloads RoHS compliant Auxiliary contacts standard (1 N.0.)

More information

pointofsale available at your local trade outlet

pointofsale available at your local trade outlet pointofsale available at your local trade outlet pointofsale products IP65 pushbuttons Ø22.5mm Contact rating @ 240V AC 10A Resistive (AC1), 6A (AC15) PB01C PB02C PB03C PB04C PB05C PB06C PB07C PB08C PB09C

More information

SECTION (16410) - ENCLOSED SWITCHES AND CIRCUIT BREAKERS

SECTION (16410) - ENCLOSED SWITCHES AND CIRCUIT BREAKERS SECTION 26 28 16 (16410) - ENCLOSED SWITCHES AND CIRCUIT BREAKERS PART 1 GENERAL 1.01 SUMMARY A. Section Includes: 1. Individually Mounted Switches and Circuit Breakers Used for the following: a. Service

More information

Installation Manual Updated May 2017

Installation Manual Updated May 2017 Code No. LIT-12012114 Installation Manual Updated May 2017 JC-VSD Factory Packaged (FP) Series II drive frames 4 8, Type 1 and 3R Johnson Controls variable speed drives Disclaimer of warranties and limitation

More information