Condensed release notes form Virtual DMIS 6.0 to Virtual DMIS 8.0

Size: px
Start display at page:

Download "Condensed release notes form Virtual DMIS 6.0 to Virtual DMIS 8.0"

Transcription

1 Condensed release notes form Virtual DMIS 6.0 to Virtual DMIS 8.0 Virtual DMIS 8.0 System Requirements Link here to check your upgrade status and price to Virtual DMIS 8.0 To use Virtual DMIS, you will need: Supplied by vendor: One Virtual DMIS Install DVD or download from a server Hardware protection device (License key and Dongle) Upgrade number (only if you are upgrading from an earlier version of Software) Computer Hardware: Pentium Dual Core processor (minimum) 2GB RAM minimum, greater 4 GB Preferred 500 GB Hard disc, 7200 RPM with minimum 8 MB buffer one PCI-e slot for external PCI box. CD/DVD drive Windows compatible mouse Available COM port, two ports if using VIP vision system Supported Operating Systems Windows 7 Professional 32 Bit Service pack 1 Windows 7 Professional 64 Bit Service pack 1 Windows 10 Professional 32 Bit Windows 10 Professional 64 Bit The following Operating System is NOT Supported: Windows XP Supported controller Systems IMS Onmotion controllers Renishaw UCC controllers IMS M9 controller is obsolete and is not supported and must be upgraded to Onmotion. Important Note: Users installing Virtual DMIS on a network must provide Virtual DMIS with Administrator Privileges with access to the registry. Valid as of 05/01/2018 Metrology Support Systems, llc. i.com

2 Virtual DMIS Version 6.0 Release Notes

3 IMPROVEMENTS User Interface (U.I.) The U.I. has been remodelled to reflect the Windows Vista colour schemes and operation, but is also compatible with Windows 2000 and Windows XP.

4 The detailed changes included the streamlining of the Graphics toolbars and re-grouping of the icons contained within these toolbars into easier to use and more logical menus. New Graphics Toolbar User definable Toolbar Show Menu Using a procedure of dragging and dropping up to 10 frequently used icons can be replicated from the smart tool bar to the new User Definable toolbar. If required icons can be removed from the User Toolbar by selecting the RMB while highlighting the icon to be removed.

5 If required the text area to the right of new tool bar icons can be turned on and off to provide a larger Graphics Area. A setting in the [GRAPHICS] area of the VMS.INI file controls the display status. When set to WITHTEXT_R_TOOLBAR=1 the Icons and text will be displayed When set to WITHTEXT_R_TOOLBAR=0 only the Icons will be displayed e.g. [GRAPHICS] WITHTEXT_R_TOOLBAR=1 or [GRAPHICS] WITHTEXT_R_TOOLBAR=0 With Text Without Text NOTE: Prior to any edit to the VMS.INI always ensure that a backup of the existing file has been made.

6 If required the transparency of some of the drop down menus and prompt windows can be controlled. A setting in the [GRAPHICS] area of the VMS.INI file controls the transparency status. When set to UITRANSPARENCY=0 the menus are not transparent. The transparency increases as the value increases, a range of 0 to 50 is suggested, the default setting is 20. [GRAPHICS] UITRANSPARENCY=20 UITRANSPARENCY=0 UITRANSPARENCY=50 UITRANSPARENCY=20 NOTE: Prior to any edit to the VMS.INI always ensure that a backup of the existing file has been made.

7 MET Reporter The new output method is called Met Reporter. Met Reporter produces reports in an entirely new output format that is real time configurable and offers a What You See Is What You Get (WYSIWYG) editing environment, with the addition of a graphics capability. Met Reporter is accessed via the Data Manage icon. Some of the new output report capabilities are illustrated in the screen capture below. Nominal and tolerance data can be dynamically edited; there is no need to re-output information or re-run a program to correct input errors e.g. Nominal or Tolerance values A stand alone MET Report Viewer is provided so that the MET Reports can be read independent of computers that have Virtual DMIS installed. For detailed instructions on the capability and use of MET Reporter please see the manual in the Document folder of Virtual DMIS version 6.0 CD. NOTE: A development is planned to send MET Report files to Excel.

8 Q-DAS Interface Q-DAS software uses statistical methods for quality management including, automatic recording of measurement data, statistical evaluations, visualization and administration, it is used by more than 5,000 companies worldwide. For detailed instructions on the capability and use of the Q-DAS interface please see the manual in the Document folder of the Virtual DMIS version 6.0 CD. The Q-DAS functions are accessed via RMB (Right Mouse Button) selection in the graphics area.

9 Excel Output Option Excel Output interface may be purchased as an option. NOTE: Microsoft Excel is NOT included in the option; the User must provide their own version of Excel, minimum Excel 2000 Professional or a later version. One of the changes introduced at Virtual DMIS version 5.5 was the ability to change the default file reporter from Notepad to Excel; at Virtual DMIS version 6.0 the functionality of this option has been improved. This change in effect results in Virtual DMIS having two Excel output options, a) The original method where each OUTPUT/ or TEXT/OUTFIL command was proceeded by a command to control the required column and row position of that output e.g. CALL/EXTERN,DME,'V3DXLPOS',1,COLA,ROW12 The procedure for use and Part Program commands for this method remain un-altered apart from an improvement to the CALL/EXTERN,DME,'V3DXLPOS',1,COLA,ROW12 command which now allows the use of variables for Column and Row e.g. CALL/EXTERN,DME,'V3DXLPOS',1,COLPOS,ROWPOS b) Excel output as an alternative to Notepad output, the function is controlled by a setting in the Virtual DMIS initialisation file VMS.INI e.g. [GENERAL] VIEWFILE=EXCEL or VIEWFILE=NOTEPAD NOTE: Prior to any edit to the VMS.INI always ensure that a backup of the existing file has been made.

10 In a similar manner to Notepad reporting (Default.Rep) the outputs are automatically positioned in a pre-formatted default Excel report VMSDTSAVE.xls. The VMSDTSAVE.xls file MUST be used i.e. User created template files are NOT allowed. If Excel output is active the Output Setting menu option to allow Folder and Filename selection is greyed-out, see below. The system will default to the current Users Report folder e.g. C:\Program Files\Virtual DMIS\Users\Administrator\Report NOTEPAD Mode EXCEL Mode

11 Excel UI Operation Through the UI selection of the Output Window <> Output Feature icon initiates the Excel Report. NOTE: If the View File icon is selected and no function occurs this indicates that there is no Excel Report currently open, the Output Feature icon should be selected. The Excel Report Header window will appear. Once any inputs are completed select Open. The Header and the contents of the Output window will be sent to the Excel File.

12 In a similar manner to a NOTEPAD file, selecting the View File icon can either Show or Hide the Excel file. In Excel mode a pop-up menu will allow selection of the required action. View File The Excel file may actually open in status minimised and will require maximising from the Windows Programs toolbar. Hide Show The Excel file MUST be Showed and Hidden via the View File icon, viewing and closing the Excel file through Windows Explorer or Excel will lock Virtual DMIS and may entail a complete system re-start. Also, only one Excel file can be open at any one time.

13 The style of the pre-formatted Excel file is shown below. Once the required Excel Report is complete it can be saved to any Folder and Filename To maintain the correct format the Excel file MUST NOT be saved until the Excel Report is completed. To save an Excel report select the View File icon and then option Save As. View File The Excel report should then be closed, select the View File icon and then option Close.

14 If the Close option is selected without saving the current Excel Report the User will be prompted to Save As the Report. Selection of Cancel will result in the contents of the Excel Report being lost.

15 Excel Part Program Operation In Part Program mode the first OUTPUT/ or TEXT/OUTFIL command encountered initiates the Excel Report. Each following OUTPUT/ or TEXT/OUTFIL command will automatically position itself in the Excel Report. No further Excel commands are required until after the last OUTPUT/ or TEXT/OUTFIL command when it will be necessary to Save and Close the Excel Report. To Save an Excel Report created using the new method. CALL/EXTERN,DME,'V3DXLDFSAS','C:\Project\Report\New Excel.xls' To Close an Excel Report the created using the new method. CALL/EXTERN,DME,'V3DXLDFCLS' If the Close command is actioned without saving the current Excel Report the contents of the current Excel Report will be lost. If the Save and Close commands are not actioned the Excel Report will remain open and subsequent runs of the Part Program will be added to the original Excel Report.

16 Cylinder Measurement To remove measurement uncertainty when measuring a Cylinder without a nominal definition a change has been made to the point calculation algorithm. The first three points MUST now be measured as close as possible to normal to the axis of the cylinder, they will in effect create a plane which is perpendicular to the axis if the cylinder. Additional points may be taken in any order and in any location as long as sound measurement practices are followed. The direction of the vector of the cylinder will be from the position of the first three points to the most extreme point i.e. similar to the previous method. Cylinder First three

17 RPS (Reference Point System) alignment. With RPS if an initial component alignment was not carried out the software was faced with multiple possible solutions, i.e. typically up to four possible alignments. To ensure the correct alignment without creation of an initial coordinate system the Constraints menu has been appended to the RPS window. Selection of the Use Features box opens the new Constraints menu, see below. Features and their required nominal positions can be added to the Constraints menu and thereby influence the alignment achieved. The new method will select the best coordinate system using the input Constraint features to aid the alignment. The result-achieved should be that the original six Features (3-2- 1) should have zero errors in their defined axis and the component axis system should be correctly orientated. NOTE: The constrained features positions will reflect any errors in the manufactured component.

18 The DMIS code for RPS has been updated to reflect this new functionality, the standard six dimension RPS alignment, CALL/EXTERN,DME,'V3DRPS', D(PC1), ZDIR, FA(PL1), 0.000, FA(CO1), $ , FA(PT3), , YDIR, FA(CR2), , FA(CR3), $ , XDIR, FA(CR2), has been modified to allow extra features to be included, example code highlighted in blue below. CALL/EXTERN,DME,'V3DRPS', D(PC1), ZDIR, FA(PL1), 0.000, FA(CO1), $ , FA(PT3), , YDIR, FA(CR2), , FA(CR3), $ , XDIR, FA(CR2), , $ XDIR, FA(PT1), 18.15, FA(PT2), 87.65, YDIR, FA(PT3), 40.35, ZDIR, FA(PT1), 0.0

19 Best Fit Co-ordinate By 3 Points Best Fit Co-ordinate By 3 Points, Use Nom option, now allows group selection of the required points by two methods. a) Rapid double Left Mouse Button the required Points in the Feature database will transfer the Point labels to the Best Fit Features field. b) Highlight the top Point label in the required group, hold down the keyboard shift key and then select the bottom Point label in the group, all the labels will become highlighted.

20 Drag and drop the group into the Best Fit Features field. Select Apply to action.

21 Graphics Output Graphics Output now allows group selection of the required features. Highlight the top Feature label in the required group, hold down the keyboard Shift key and then select the bottom Feature label in the group, all the labels will become highlighted. Drag and drop the group into the Graphics area. The Feature boxes will be positioned close to their Features, but may required some manual re-positioning, see below. More than one Feature type Plane, Circle, Cylinder and Cone etc. may be included in one group selection.

22 Selection of non-consecutive Features is also possible. Highlight the first Feature label, hold down the keyboard Ctrl key and then select and highlight the remainder of the required Feature labels. Drag and drop the highlighted group into the Graphics area.

23

24 A new option Items has been added to the menu displayed on RMB selection in a graphic result box. The Items option allows selection of the parameters displayed in the graphics result box.

25 Points Labelling Individual points can be labelled automatically into the 3D graphics area. This function can be enabled via RMB (Right Mouse Button) selection in the graphics area. The labels will be positioned in the 3D space in the Normal (IJK) direction. Using the Set Label Position option allows the offset between measured point and the label to be set.

26 Collision Recovery The automatic move collision avoidance function has been improved by allowing for the probe tip radius. The Safe zone can be set using the Probe Tip Radius ratio in Vms.ini. [MOTION] COL_SAFEBALLRADIUSRATIO = 1.0 If COL_SAFEBALLRADIUSRATIO is smaller than 1.0, possible collisions will only be checked in the probe tip centres current move direction. To use this function, System Setting Using warning box to resolve collision and Enable Warning on the Tools drop down menu must be selected. NOTE: Prior to any edit to the VMS.INI always ensure that a backup of the existing file has been made.

27 Other Improvements The Sensor Definition window default is now set to stay open on Apply. The change saves re-selection of the Sensor Definition window and therefore makes creating Child sensors easier and faster. If required the Window can be set to close on Apply. The default settings of the Project <> New window have been changed to, Clear sensor database de-selected and Recall coord set to the MCS, see below.

28 It is no longer necessary to be in the correct Working Plane to extract Arcs from a CAD model. On some occasions the Feature Measurement window failed to close when another function was selected, the software has been enhanced to minimise the number of occasions where more than one function window is displayed. In automatic curve measurement the button option to Cancel the procedure has been removed and replaced with selection of the X button Cancel Procedure When displaying curves in the Feature Graphical Processor (FGP) window, if the first point failed to project onto the nominal curve the form error was set to zero, this could produce a misleading graph, the new procedure is not to display the failed point.

29 When surface scanning using an OnMotion controller, if Project act point to CAD Model is active, the probe tip diameter compensation will be use the vectors (IJK) obtained by projecting the actual point onto the CAD model.

30 The Data Manage icon now provides access to two functions, the default display MET Reporter, and Project Manager. MET Reporter Project Manager The currently loaded DMIS Part Program Folder and Filename will be displayed if the cursor is placed over the Part Program database tab. This re-introduces a function that was previously removed.

31 The Calibration sphere s Sphere Bounding Vector can now be set within a Part Program by adding the vector (IJK) to the following DMIS command e.g., F(Label)=FEAT/SPHERE,OUTER,CART,X,Y,Z,DIAMETER,I,J,K F(90BALL)=FEAT/SPHERE,OUTER,CART,150.2,84.5,90.9,25,0,0,-1 A setting in the Virtual DMIS initialisation file VMS.INI enables this function e.g. [SENSOR] USEACTIVESPHEREDIRFORCALIB=1 or USEACTIVESPHEREDIRFORCALIB=0 NOTE: Prior to any edit to the VMS.INI always ensure that a backup of the existing file has been made.

32 BUG FIXES 1) [Bug Fix] If the auto mode was selected in the Co-ordinate Window Offset Co-ordinate by 2 points and then Offset Coordinate by 3 points was opened, the distance input fields were disabled. 2) [Bug Fix] Co-ordinate function Offset Co-ordinate by 3 points was modified at version 5.5 to allow the input of minus Nominal position values, in some instances this lead to the resultant axis system being flipped through 180 degrees e.g. Dir Z instead of Dir +Z, this bug has been corrected.

33 3) [Bug Fix] Following Virtual-DMIS start up the Output Window <> Output Setting <> Output file setting did not work correctly. The output file setting only worked when the Output Setting Window was opened and the Select a New File option was activated. 4) [Bug Fix] When selecting Circles and Slots from CAD models the probability of the generation of the correct Normal vector (IJK) has been improved. 5) [Bug Fix] Error created during the Intersection of a CAD model and Feature Line has been corrected. 6) [Bud fix] Part Program command Endfil now clears all external Macros and their file paths. 7) [Bug Fix] The Outside Tolerance Limits in the Output window will be updated automatically when the unit type is changed.

34 8) [Bug Fix] Depending upon the setting of the Windows screen properties the Virtual-DMIS status bar sometimes disappeared. 9) [Bug Fix] Improvement to the Sensor Configuration Window to minimise problems of displaying the Sensor models, bug only experienced on a small number of computer systems. 10) [Bug Fix) On post v5.3 Virtual DMIS systems fitted with a UCC controller and an ACR3 Auto change rack the last GOTO position prior to a sensor change may be ignored causing a possible collision situation. This situation was in particular evidence if the sensor change was called from an external macro.

35 Highlights of Virtual DMIS 6.5 MetReporter MetReporter View MetReporter can now be viewed in real time during a programmed inspection. MetReporter output MetReporter output can be disabled on the right toolbar. MetReporter generates graphic files, which need to be cleared or saved periodically. For customers who wish to use Excel or default notepad output, this function removes the need for MetReporter file maintenance. Header and footer Header and footnote graphics can be added. Supported formats are bitmaps, JPG and GIF. Dual Screen view MetReporter can be displayed in the second monitor, using the following settings in Vms.ini. If only a single monitor is connected, this setting will be ignored. [METREPORTER] DUAL_SCREEN=1

36 Append data When multiple features have been measured with the same label, nominal and tolerances, they can be merged in a group feature, and the trend graph displayed. User-selectable output formats such as chart, histogram, chart with histogram, (or with SPC Module installed) the various SPC output graphs Merge Files MetReporter supports loading multiple documents and merging them into one MetReporter file. MetReporter SPC Statistical Process Control Powerful new SPC capability has been added to MetReporter. Xbar Charts For sample sizes greater than 10, the Xbar-S function displays the mean and standard deviation of the sample. When the sample size is less than 10, the Xbar-R function gives mean and range (maximum to minimum) Process Capability MetReporter can output various process capability metrics, e.g. Cp, Cpk, Pp, and Ppk

37 CAD Model options Balloon location The Align Windows in 3D Space function attaches the actual data close to the measured feature on the graphic. This function is very useful to display point profile errors on a CAD model.

38 CAD model into MetReporter Cad Model with data The CAD model can now be integrated into the MetReporter file. Measured data and tolerances are attached pictorially to the model to give a much more direct representation. Display parameter selection Display parameters can be set to the customer s preference. The example below shows only the actual measured features, displayed as whiskers around the perimeter of the screen.

39 CAD and VRML When many points have been measured, the whisker display can be confused and features difficult to identify. VRML Layer VRML layer can be omitted to improve loading speed of CAD models by setting in Vms.ini. The default will be MAKECADLAYER=1. [PROCESS] MAKECADLAYER=0 // Do not make VRML layers MAKECADLAYER=1 // Make VRML layers Surface measurement point gathering After defining the desired points on the surface using the UV coordinates, the measurement path and point order can be generated as a zigzag, as opposed to the previous raster scan method. Zigzag operation is selected using the checkbox below. Curve label on database Curves using the intersection between a plane and a CAD model will be generated in order, so that consecutive curve numbers are connected. Curve merge method Curves to be merged are selected from the feature database using the shift key+lmb if they are in a continuous numerical block, or using the CTRL key and left mouse to make a non-continuous selection. When merging curves, Virtual DMIS connects the curves in the order that they were selected.

40 All curve merge A new menu Merge All Connected Curves has been added. All curves connected with a selected curve will be merged automatically. Surface analysis with topographical display The resolution for surface analysis has been improved as shown below. (a) Tol Mode (b) General Mode The previous In/Plus/Minus display has been replaced by a continuous topographical display. Offset 3D points generation A new 3D Points Generation function with offsets from 2D curves or 3D curves has been added. In the following picture, the offset direction has been rotated by 90 for the tangential vector. Offset direction Offset Math Engine Angle between calculation A new property has been added in the vms.ini for the angle between calculations. Two types for the angle between calculations can be set using the following parameter.

41 [GENERAL] ANGB_TYPE = 1 : Uses the strict angle from the feature vectors. ANGB_TYPE = 2 : Calculate the angle that is close to the NOMINAL angle. Deviation calculation An absolute position function to define a calculation method of deviation from Actual to Nominal has been added. In all calculations, the deviation is calculated as: Deviation = Actual Nominal. When Absolute Position is selected, the calculation is Deviation = Actual Nominal. This function can be set in the dialog box for output setting. Tolerance True Position The 3D true position function allows Spheres, Cones, and Points. Tolerance input When the same tolerances are required for the LWTs and the UPTs on feature position values, select the title cells for the LWTs and the UPTs and input a tolerance value. Selecting UPT title sets tolerance for upper and lower X,Y,Z coordinates. Selecting LWT title sets only the lower tolerance for X,Y,Z coordinates. Profile tolerance When the tolerance bandwidth is not centred on nominal, the profile tolerance will be calculated with the points that are out of tolerance. [Previous Version] PROFL PFL13 Profl * PtNo X Y Z DX DY DZ DEV Max error = at Point 18 [Latest Version] PROFL PFL13 Profl PtNo X Y Z DX DY DZ DEV Max error = at Point 18 Tolerance Output Tolerance output description can use geometric feature descriptions instead of FEAT or FA. This greatly improves the clarity of the report. Setting:

42 [GENERAL] USEFEATTYPE_TOL_DESCRIPT=1 Example of Old Style DISTB DTB2 FEAT(SCPT1) FEAT(SCPT2) MM Distb *++++ PARLEL PAR2 FA(CY1) FA(CY2) MM Parlel *++++ Coordinate System Sensor Example of New Style DISTB DTB1 POINT(SCPT1) POINT(SCPT2) MM Distb *++++ PARLEL PAR1 CYLNDR(CY1) Ref CYLNDR(CY2) MM Parlel *++++ MCS label MCS label is reserved for use by the Machine Coordinate System in the coordinate setting windows. Bisect coordinate system A new function has been added to the Offset Coordinate by 2 Points Dir dropdown window. BISECT optimises the coordinate system from two features to minimise the rotation errors within the selected working plane. Reset By Angle The check button of By Angle in the window for rotating coordinate systems will be unchecked automatically when a new project is started. Own length and diameter for offset child sensor Previously, all child sensors were defined as having the same probe tip diameter as the parent sensor. Each offset child sensor can now be defined with its own length and diameter, irrespective of the Parent sensor. Child sensors created via rotation of the probe head remain the same as the parent. Show multiple sphere Multiple calibration spheres can be added in the graphics area. A menu item Show Calibration Sphere/Hide Calibration Sphere is added to the popup menu in the graphics area, as shown below.

43 If there are more than one calibration spheres, the best calibration sphere for a specific attitude can be selected automatically. General Improvement of the CONCAT function The number of nested parameters within the CONCAT function can be increased by adding a comma between strings or variables. CONCAT('TOF,T2,X',XPT1S,',Y0.000,Z ,C0.000') Intersection The intersection points between a line and a square slot can now be generated from the features. Update nominal feature with new PCS In order to update nominal features with a new PCS, the check button in the Coordinate setting windows must be checked. In DMIS versions after 4.0, the nominal features were updated automatically whenever a new coordinate system was created. This functionality has reverted to the previous method, with the option of updating the nominal via a check box. This is to provide a more consistent user interface. The function to update nominal features can be enabled and disabled with the following DMIS code. CALL/EXTERN, DME, V3DUPDNOM,ON (or OFF).

44 Construction cone and palne Circle UI within the Construction smart toolbar has been implemented to create geometric relationships between cones and planes. Plane Cone Circle +D Cone Circle +D Plane -D Circle Show/Hide text for the toolbar The text for the toolbar on the right side of the graphic UI can be hidden and shown in the Virtual DMIS.

45 Fast Data Translation In order to use fast data translation for scanning using UCC, TCPIP communication must be used. [CONTROL] DRIVERIP= //Inside one computer DRIVERPORT=1407 DMIS preperation New UI is available to assist users in creating a program in Learn Mode. In order to use this function, the following must be set in vms.ini [GENERAL] USEDMISHELPER=1 With the new interface enabled, the following dialog box will appear, allowing the user to enter parameters such as sensor settings, output file, move speeds etc. The Advanced option within this box provides direct creation of variables and input of the MetReporter header. EZ Tools Working Plane update When using EZ Tools to set up the coordinate system, the working plane can be set automatically if needed.

46 The range of EZ Tools has been expanded. Virtual Vision+ New Light control A new lighting control system has been added into the lighting control UI. Z axis move using mouse In order to move the Z-axis for the vision mode, the wheel can be used but a CTRL and a Shift button must be pressed. Save skip autofocus parameter SKIP_AUTOFOCUS will be saved the current option at the [CALIBRATION] section. Support Morphis frame grabber card Support for Morphis PCI and PCI express using MIL-LITE 8.0 framegrabbers has been added Colour camera support Colour Cameras can now be supported

47 Bug Fixes In the Vector Build, the probe can be correctly moved to the right position before circle measurements. In the collision avoidance, the problem moving to the table has been corrected. Corrected, a tool tip error displaying wrong string for the user defined smart toolbar. A crash problem has been solved when the default tolerance name is changed. Point s output to print has been fixed. Met Reporter cannot get measured data when the auto print mode is on. For the curve measurement mode with pitches, a machine moves to the origin sometimes. If the number of measured points is larger than the required minimum number of points for a feature and then the auto button is pressed, the total number of points will be used for generating points instead of the current digit displayed on the Measure window. The measured points used for generating points will be removed. Corrected, the tolerance band calculation of a merged curved with straight lines and curves. Corrected, a form error calculation for a merged curve with straight lines and curves. Corrected, auto curve measurement for a curve that is a straight line. Corrected, a normal vector calculation error for a merged curve that consists of straight lines and curves. This error happened when the start point, the middle point and the end point is on a line. So if the three points are on a line, the normal vector of a first curve will be set as the normal vector of the merged curve. Generate 3D points on a curve made duplicate points. The duplicate points caused a curve fitting error. Whenever an easy tool for setting coordinate systems, a new item is added in the combo box for Axis. This error is corrected. READ/F(CV1), File Name : A nominal curve can be imported from a file. Straightness calculation error has been fixed.

48 The square slot calculation method has been corrected in the order described in the help file. The measuring order for the slot measurement will be as the following picture. A collision error for the automatic curve measurement with a pitch has been corrected. Find Vector from GEOM in the Nominal Edit Window made a projection error. The projection error has been fixed. Geometric features created for a RPS alignment are sent to output files. These features should be used only internally for the RPS alignment. The DMIS parser will be paused while scanning and will be continued when the scanning is completed not to skip other commands such as gotos that are before SCNMOD/OFF. Other windows hid the tool tip windows in Virtual-DMIS. For example, tool tips for the smart toolbar were not shown over the other windows. The current Machine Status Configuration can be saved and will be loaded automatically when Virtual-DMIS is started. In the sensor configuration window, when sensors are sorted with names, items were duplicated for every item. In automatic probe calibration in the AUTO mode, measured points for calibration that are not needed are recorded in the DMIS codes. Two sensors with one same name cannot be defined in this version. The parent sensor list in the sensor definition dialog box could have duplicated lists. The tolerance database was not cleared at the ENDFIL commands when the clear mode in System Setting was set. [Vision] In the DCC measurement mode, the number button will not be used for setting zoom lenses. [Vision] Virtual-DMIS was crashed when a right button is clicked on the Virtual-DMIS UI while calibrating lenses. Memory for topology will be cleared when a model is deleted.

49 Memory for the Image Lists for the Vrml Layer Window will be cleared when a model is deleted. Creating feature is correctly working without VrmlLayer. Loading speed will be improved without creating VRML LAYERS. In order to use this function, the following must be declared in Vms.ini [PROCESS] MAKECADLAYER=0 Corrected a method to create cylinders from CAD models. DMIS Codes for Coordinate EzTools will be written when the procedure is finished. Best-fit algorithm for cylinders has been updated. A collision problem for circle measurement using the vector build mode has been solved. In the Best fit for the coordinate setting, wrong icons were used for ellipses, arcs and slots. Curve extractions using intersection with planes and some surfaces in CAD models were failed. This problem has been corrected. The directions of picked points on surfaces will be corrected with the view direction.

50 Stylus and Probe Change Racks Highlights of Virtual DMIS 7.0 ACR rack can use Stand Alone method The default method of communicating with the ACR is via the COM port, where Virtual DMIS issues specific commands to the lock motors. In Stand Alone mode, machine movement is controlled by Virtual DMIS; the lock motors are controlled by the ACR. Virtual DMIS has a fixed time delay between moving into and out of the port. The time delay is set on the ACR itself and has a corresponding entry in the vms.ini file. To use Stand Alone [SENSOR] ACC2METHOD=STANDALONE Multiple MCR20 Rack Support It is now possible to utilise two MCR20 racks on a single machine, increasing the number of available ports to 12. [SENSOR] RACK=MCR20 DUAL_MCR=1 MCR20 module support on FCR25 rack The FCR25 rack is designed to work with the larger diameter probe body of the SP25 scanning probe. In order to use the TP20 range of touch probe modules, it is necessary to dock first with the TM25 adaptor, then the Touch module. Virtual DMIS has implemented a sequence for changing from Scanning to Touch modules and back as follows. Scanning Module fitted Dock Scanning Module in Port 1 Collect TM 25 adaptor from Port 2. Move Z height to compensate. Collect Touch module from Port 3.

51 Touch Module fitted Dock Touch module in Port 3. Dock TM 25 adaptor in Port 2. Move Z height down to compensate. Collect Scanning Module from Port 1. The FCR system may be extended to 6 ports, depending on the rack used. Please refer FCR25 Instalation.doc on Virtual DMIS CD for details, Sensor Definition and Calibration Sensor Assembly Graphic Support for Probe Racks The sensor assembly graphic is automatically updated when the probe rack port is changed. The sensors must be built and assigned to a port in Sensor Configuration dialog box. Once the sensors are assigned, the sensor graphic on the main Virtual DMIS screen will reflect the probe mounted on the CMM, and be updated when other sensor assemblies are selected.

52 Crank Stylus Star stylus arrays can be built using a 5-Way extension (Stylus Centre). Each limb of the array has a definition for stylus length and diameter. Preset Parameters for Probe Calibration When enabled in the system settings, this new function simplifies the probe calibration routine. The default setting is Enabled. When selecting Auto Calibration (Calibrate All Sensors), Continuous Motion (Fly Mode) is set ON; Approach & Retract values are increased to 7.5mm. The previous Approach, Retract and Continuous Motion statuses are restored after calibration. Tolerance 3D Positional tolerance 3D Positional tolerance against the selected PCS can be evaluated for each individual axis, as well as overall 3D Positional Tolerance. Total Run-out support for Axis (Cylinder) to Plane Previous versions have been able to calculate the run-out of circles or cylinders. It is now possible to measure the run-out of the planes associated with the cylinder.

53 Programming Speed control Speed control is available while DMIS program is running. Control is via the numeric key pad on the IMS joystick: Menu button Turn ON/OFF speed control. 1 10% of current move speed %... 90% of current move speed 0 100% of current move speed The interactive status icon flashes GREEN / HALF RED when the speed control is active. Turn OFF Learn Mode Learn Mode is turned OFF when the Run From Current Line icon is selected. As a result of customer feedback, it was agreed that the previous method was likely to introduce inadvertent lines of code into the program: after running the program, the user may have cleared the feature database or MetReporter output files, or made an alteration to the coordinate system and these actions would be built into the DMIS program. After running a short section of the program as a test the user must remember to turn Learn Mode ON again.

54 Prompt Dialog Box This new feature enables multiple user entries from a single entry page. This is mixed format, so text, variables and button functions can be applied. Prompt Dialog Box is a standard DMIS command. DECL/INTGR, BtnVal,chk1,chk2,chk3,chk4,RadioBtn DECL/CHAR,256,EditChr1,EditChr2,EditChr3,EditChr4,ListChr BtnVal = PROMPT/TITLE,'Block Measurement',$ CHECK,'Met Reporter ON',chk1,CHECK,'OTol Only',chk2,$ TEXT,'Enter Inspector',EDIT,EditChr1,32,$ TEXT,'Input Temperature',EDIT,EditChr2,32,$ GROUP,'Process No',RadioBtn,'P100','P200','P300','P400',$ TEXT,'Gear Type',$ LIST,ListChr,'Spur/Helical','Worm','Bevel',$ BUTTON,'OK',1, BUTTON,'Cancel',2 Please refer to the sample DMIS program in the Samples folder on the Virtual DMIS CD. Grid Repeat Run feature is added. This function requires no additional programming, and minimal alteration to existing programs. To enable Grid Repeat Run, select the Re-run Within Block icon without setting a block in the DMIS code. Re-Run icon There are 3 options; Full Grid, Grid not Full and Random placement. Full Grid: The user defines the number of components and grid pitch in X and Y. The total number is calculated and the program runs for every component.

55 Grid, not Full: The user defines the number of components and grid pitch in X and Y as before, and also number of parts to be measured in sequence. Random Placement: The number and pitch must be defined. The Place area becomes active, and the user enters the numbers of the locations that are to be measured, separated by commas. The components are measured in the order that they are entered This table shows the numbering sequence for the example above. The numbering always starts at X 0,Y 0, and increases by row, then column. As the Grid Repeat function operates from the MCS, the CMM program must contain the location of the first measurement point; this is automatically generated in new programs. Existing programs need a GOTO inserted, replacing any manual intervention to move to the start position. The Grid Function requires the first part to be set to the same position on the table each time accurately enough that the probe will locate the component. This can be achieved by simply marking the table, or by manufacturing a fixture. It is good practice to mark the table for each position on the grid.

56 General Simple User Interface The number of programmable buttons in the SUI (Simple User Interface) has been increased from 8 to 20. Software Version names MetReporter and Virtual DMIS naming conventions have been brought into line, simplifying the customer s Purchasing process. MetReporter File Management Multiple file selection is available to open Met-Reporter file for merge files. Selection follows the Windows convention of shift+mouse to select a block, CTRL+mouse to toggle individual selections. UCC Driver Log File The motion driver Log file can very quickly grow if the machine is left on. The UCC driver log file behaviour now mimics OnMotion, and is OFF by default. The log file can be enabled for diagnostic purposes using the following command. To make a log file, [MACHINE] MAKEDRIVELOGFILE=1 ** Default is MAKEDRIVELOGFILE=0

57 Bug Fixes Help File Settings Within System Settings, the Video Last Frame Pause function can be used to determine the time in ms that the last frame of the Help Video is displayed. [Vision] If Edge option is unchecked and Line Form Filter is checked, Line Form Algorithm is not run. [Vision] On each magnification, the Output Data is not the same. [Vision] Pink Color appears in the image window. [Vision] An image cannot be saved in vision mode. [Vision] Laser data does not automatically send to Virtual DMIS. [Vision] Offset Calibration data is cleared by pressing close button. If Upt and Lpt's value are 0.0, the whisker mode has a problem in the MetReporter. BISECT correctly rotates coordinate in ZXPLAN on DMIS program. Act/Nom value updates as PCS on 3D Position Tolerance for Axis type. PH10M+VIP length changes from 140mm to 146mm in SensorLib.dat Probe moving path is corrected when using star probe +Y direction at A=45 or Higher during probe calibration. Met Reporter SPC - Process Capability has been corrected if tolerance has only upper limits. [Vision] Move to last focus position when failed auto focus (AF) [Vision] Move to last zoom motor position when start Virtual DMIS Vision+. It moved to zero position. [Vision] If output window box is opened before initialize, Image window box is holing. Select point on a cad model using Pick & Measure, some cad model had wrong point position (looks like project certain area) shown. [Vision] If a measurement window is opened, and user tries to measure a point, the point buffer in the measurement window is not increased. [Vision] If user clicks Features in Feature Tool Bar, Point Buffer is increased or Features are measured.

58 [Vision] The Measure Points are not deleted after measuring feature. [Vision] If the Laser Point has failed during measuring point, the Measure Point is not deleted or the Laser Point is not initialized. ANGLB output description has Err instead of a feature label when evaluate Angle Between using Feat to Feat during DMIS program running. ANGLB ABB5 PLANE(PL1) Err ANGDMS ANGLB ABB5 PLANE(PL1) CYLDR(CY1) ANGDMS

59 Highlights of Virtual DMIS 7.5 CAD Active Matrix Plus For the first time it is possible for Active Matrix to extract the nominal data from the CAD file without translation. This Direct CAD method ensures that no data can be lost or corrupted in translation. By having Virtual DMIS and Active Matrix Plus running at the same time, the nominal data can be sent directly to the Virtual DMIS feature database. Supported geometric features are: point, circle, line, cylinder and curves. Pick and Measure By default, Pick and Measure projects the point onto the CAD data. Occasionally when using pick and measure to generate a point on a CAD model, the point projection was unsuccessful. This was due to imperfect CAD model creation or translation. The new function below gives the user the option of projecting onto the CAD graphic surface rather than the CAD data. The resulting points will be correct on a plane, but may have small errors on a curved surface because of the rendering of the graphics.

60 DMIS Write DMIS MEAS function After selecting single or multiple features, it is now possible to create the DMIS MEAS commands with a single button press. Write DMIS MEAS automatically generates the measurement position and vector, and in the case of Circle features, prompts the user for the number of points required. Points and Circle feature types are supported. In the example above, if the user selects Write DMIS MEAS, the following lines are written automatically. MEAS/POINT, F(PT2), 1 PTMEAS/CART, , , , , , ENDMES Over-Tolerance Output via DME The function can evaluate each output against the tolerance value and set a flag that can be used to e.g. provide a text message, stop the program, or send a warning over TCPIP.

61 DECL/INTGR, IsOverTol CALL/EXTERN, DME, 'GETOTOLVAL', IsOverTol To reset Over Tolerance flag, CALL/EXTERN, DME, 'RESETOTOL' TCP-IP communication with Virtual DMIS. TCP-IP communication Virtual DMIS has now implemented bi-directional communication with external software or devices over TCP-IP. Simple text or CHAR variables can be sent and received. Typically this could be data to an external SPC package, instructions to and from a pallet loader or robot arm, or nominal data from an external application. The function is similar to RS232 communication, but without the distance and speed limitations. CALL/EXTERN, DME, 'SENDTCPMSG', Message Example, CALL/EXTERN, DME, 'SENDTCPMSG', END_PROG Virtual DMIS can initiate and stop communication. Re-connect server, CALL/EXTERN, DME, 'SETTCPIP' Disconnect server, CALL/EXTERN, DME, 'CLOSETCPIP Clear Surface The clear surface function has been modified to provide direct clearance against the current PCS. Previous versions required a plane definition in order to evaluate each Clear Surface position. It is now possible to use the axis labels from the current PCS to enter the Clear Surface value. DMIS code: SNSET/CLRSRF, ZDIR,

62 Measurement Automatic circle, cylinder or cone measurement. The joystick keypad can be used to control the CMM. This group of functions is enabled by pressing the Rotary Button. The automatic measurement assumes that the feature is normal to the probe direction. Circle: Move the probe to the centre of the circle under joystick control. Open the Circle measurement window and press Rotary. 4 equispaced points are taken. Cylinder: As for circle for the first 4 points. The probe returns to the centre. Use the keypad numbers 1-9 to set the depth of the second set of measurements in mm. the Minus button allows correction if the user overshoots. These can be repeated until the depth is correct, then press Rotary. The minus button can be used to reverse out of the feature to a clearance position. Cone: exactly as cylinder. To use depth move, [CONTROL] JOYMOVE=1 ** Default is JOYMOVE=1

63 Direct Entry of Feature Measurement Number of Points. In addition to the conventional slider to select the number of points to be measured, RMB in the Points window opens a window for direct numerical input. Graphics Display label for all features (ACT/NOM) Feature labels can be displayed in the graphic area. This enables the user to identify features more easily.

64 Act/Nom plane graphic size The Act/Nom plane graphic size in the graphics area is determined using the measured points. Previous revisions had fixed size planes which would overlap. Graphics Output The number of decimal places on Graphics Output balloon can be set. It can be selected decimal place on Pictorial Report dialog box.

65 Sensor Sensor Definition naming. Virtual DMIS now automatically generates a descriptive label for new sensors, based on the Port number, A angle and B angle. If the probe rotation is changed either using the slider or direct entry, the label is dynamically updated. This is a benefit when identifying sensors within DMIS programs. Automatic MGAGE Creation If the datum ball has not previously been defined, this function creates a nominal datum ball and automatically measures it to create the MGAGE. This removes the need to manually measure the datum ball, and repeat the measurement under CNC.

66 Machine Location after Probe Change. The machine behaviour after a probe change has been improved. After collecting the new probe assembly, the machine retracts to DOCKDIST as before, then moves to the DOCKSAFE position. This is such that the stylus centre is a minimum of 50mm above the DOCKDIST position. The position can be further modified using the parameters below. Any DOCK_ZOFFSET value is added to the 50mm minimum. By taking the sensor length of the new assembly into account, this new procedure ensures that the probe is clear to index, and minimises the risk of a probe collision when moving back to measure the part. To use this function: [SENSOR] DOCKSAFE=1 DOCK_XOFFSET=70 DOCK_YOFFSET=-100 DOCK_ZOFFSET=30 Default DOCKSAFE Default value for DOCK_XOFFSET, DOCK_YOFFSET and DOCK_ZOFFSET are 0.0 Modified position If DOCKSAFE=0, then the machine will move to the last position before the probe change command as before. This does not take sensor length into account, and may result in damage.

67 Coordinate Mirror Axis. Mirror Axis added for X axis on XY PLAN. Mirror axis uses for car frame measurement with dual arm machine. [GRAPHICS] COORDDIRTYPE=3 General All tolerance values are set to zero when A new Project started Starting to make new DMIS program. Scan Speeds Default MAXSCNVEL value is changed from 100 to 20 with MMPS for the OnMotion controller. Show/Hide Nominal Database Users who do not use CAD data do not normally need to see the Nominal database. This function hides the nominal database for Feature, Tolerance and Sensor. If the nominal database is highlighted, it is possible that the user will try to create tolerances and constructions using the nominal data. Tolerances cannot be applied to a nominal feature, and constructions from nominal may result in rounding errors (There is a system setting that allows the user to automatically round the nominal values when creating nominal features from a measured actual.)

68 Nominal sensors are shown in the Actual sensor database when the nominal databases are hidden. There are graphical indications and text messages to warn the user that a Nominal sensor is in use. There is toggle switch to show or hide nominal database. With the Feature database highlighted, right mouse button on ACT icon will open the pop-up window. Size Dialog box The nominal value in the size dialog box now can be edited directly. This brings the Size and tolerance into line with the Output window.

69 Virtual Vision+ Nominal Graphic display When in Manual mode during a program, the nominal circle size is read from the program and displayed on the Vision screen. Start-up issues The progress bar on vision screen occasionally caused the software to freeze at startup. This is resolved. Press the mouse button during Vision+ initialisation could cause the software to crash. This is resolved. Edge Point Display Default setting of show auto-measured points is changed from OFF to ON. Manual Mode If a program used Manual mode for measuring, a flag was not being cleared which prevented further measurements. This could occur when exiting a program via Stop Immediately icon, at the end of a file, or if the user changes the measure mode on status bar. This is resolved Probe Change TP20 module can drop & pick in MCR20 when exchange Touch Vision Probe. Also PROBE OFF is set when select Vision. PROBE ON is set when select touch probe during pick the module from MCR20. It can use DOCKSAFE for safe position after drop or pick the TP20 module. [SENSOR] DROP_PICK_PRB=1 Bug Fixes Probe is moving by deviation of sensor length when toggle Vision/Touch Probe. Calibration crank probe had wrong path with A30B180, Y Dir at 0,0,-1 sphere bounding vector. [Vision] Coordinate values with laser value when user sends laser data to Virtual-DMIS. [Vision] The move value was not updated by using array measurement. [Vision] The MCS and PCS Coordinate can be deleted or repeated by using array measurement. [Vision] Corrected, the Laser Point can be operated by using array measurement. [Vision] Finish measurement does not work when display minimum point on measure window box.

70 Reserved DMIS word cannot use in a DMIS program. Plane profile tolerance does not output when running DMIS program at first time. VmsDriver & Virtual DMIS communication sometimes disconnected when using clear surface in DMIS program. Displaying Notepad or Excel for Open Text Output With is corrected with foreign Language. [Vision] It can not measure any feature after using DCC MAN mode (MODE/MAN) in DMIS program. Turn off DCC Manual mode when press Stop Immediately button or read ENDFIL in DMIS program or select a measure mode on status bar. Show distance type as 2D Distance instead of 3D if select X,Y or Z axis for Type. Failing to truncate numbers after the decimal point on a balloon in graphics output for nominal circle diameter. Construction actual curve ( CONST/GCURVE ) did not generate the actual curve in DMIS program. Nominal file name corrected to avoid error 3621 when recreate nominal curve if nominal curve existing in feature database. * 3621: Unable to define undmis external nominal for GCurve Nominal PCS curve file (.Pcs.Nom) is not created when using DMIS code READ/F(CV_1),FileName, if nominal curve existing in feature database. Tolerance lines do not use same scale as nominal curve in curve profile (2D Graph). GDI value is accumulating when using graphics output, thus computer becomes slow when graphics output constantly used. Corrected, if project name is more than 70 characters, popup menu position is changed to left side instead of right side. Balloon movement is slow on graphics output with some graphics card. Actual point data does not update in DRO window box when enabling Show Last Feature during DMIS program running.

71 Virtual DMIS Version 8.0 Release Notes - 1 -

72 User Interface Some of the optional functions listed in this document indicate that changes must be made to the VMS.INI file to allow them to operate. It is IMPORTANT that the User is aware that this file controls the operation of Virtual DMIS and as such a backup copy should be made prior to making any changes. The VMS.INI file is read when Virtual DMIS is loaded and written to when it is closed. Any manual changes to the VMS.INI file should be made before Virtual DMIS is started. The VMS.INI file is a Notepad file and will be found in the current Microsoft Windows folder e.g. C:\Windows The VMS.INI file is sub-divided into sections, each section is headed with it s title in brackets e.g. [CONTROL] The optional changes should be placed in the correct section e.g. [GENERAL] AUTOIDLE=1 A line will be ignored by the system if it starts with $$ e.g. $$ AUTOIDLE=0 Graphics Area [Improved] Circle label position on graphics area is changed from circle center to edge of circle. This can avoid overlap problem. The position of the circle labels has been changed from the centre to the edge of the circle on the graphics. This avoids overlap. Sensor [New] Auto clear surface function is available in PROG mode. Clear surface direction is determined by a sensor direction. Auto clear surface generates GOTO position automatically when measuring feature or changing sensor. UI is in Senor Settings to input clear surface position. DMIS code: SNSET/CLRSRF, AUTOCLS, X1,Y1,Z1,X2,Y2,Z2 SNSET/CLRSRF, AUTOCLS, -12.0, -12.0, -80.0, 137.0, 137.0,

73 Where, X1,Y1,Z1: (-) Direction from datum Left Bottom coner, X2,Y2,Z2: (+) Direction from datum Right top conner. [New] Renishaw PH20 probe available with Renishaw UCC T5 controller. Head Touch Arc Move Head Move Rotation Auto determine probe angle when auto measurement [Improved] It can re-select current sensor for PH20 to restore original orientation if PH20 head is rotated by joystick or auto orientation. [Improved] IPPDME. Show all probe labels from UCCServer in Virtual DMIS sensor database for PH10M(or PH10T). It distinguishes parent sensor from child sensor. [Improved] IPPDME. PH10M. It is possible to calibrate all sensors from Virtual DMIS sensor database

74 [Improved] IPPDME. PH10M. Sensor length no longer uses zero in VMS.INI so that AUTO measurement is enabled without ZERO length error message. [New] PH20 does not need to create sensor label when rotating sensor orientation. Only the rotate angle is required. There are 2 options to rotate orientation: rotate and HD Move. UI is on Machine Move dialog box. Rotation Head: CALL/EXTERN, DME, 'V3DPH20ROT', , Head Move Rotation: CALL/EXTERN, DME, 'V3DPH20HMV', , , , , [Improved] The determined PH20 head angle depends on sensor length when measuring the outer circle with head touch. There was a probe body hitting problem if long sensor length with short stylus was used because head angle was so small. In this case, lock the A angle to avoice probe body hitting problem. Measurement [Improved] Additional GOTO position has been added to avoid hitting first measurement point when measuring features with FLY/ON

75 [Improved] The INNER/OUTER circle is determined by the trigger direction of the first 3 points used in the auto measurment of circle. Previously, if the circle was INNER then the next circle would be automatically presumed to be INNER, and same for OUTER. [New] Extended measurement window has been created. Nominal, Tolerance, Inner/Outer, Output and Approach/Retract are available in this extended window. [PROCESS] MEAS_NOM=1 [Improved] Creating a curve using importing text file has worked only with Metric. Imperial has been added. [New] Apply Fixed Direction for Auto Circle/Cylinder Measurement check button is added in System Setting at Automode tab. Auto circle measurement sequence is 0(E), 90(N), 180(W) & 270(S) when this button is checked. The direction always follows MCS. [Improved] IPPDME. Added scanning function for Known/Unknown Line, Arc & unknown circle. DMIS program is available too

76 [Improved] Multi section cylinder auto measurement is available for inner/outer cylinder. Depending on the angle of the sensor, the measuring path of the cylinder will be calculated accordingly. Coordinate System [New] When the Update Nom checkbox is ticked, the Nominal and Actual values will both be set to zero when translating datum. This function only works with the following setting: [GEOMETRY] COORD_NOM_UPDATE=1 Default is

77 [New] Best Fit Coordinate system: Create best fit coordinate system using multi features using deviation values. If the Create New Feat checkbox is ticked, new best fit features (_BF) will be generated and only the actual dataset will be updated. Programming [Improved] Learn Off when running DMIS program is optional. [LEARNMODE] LEARNOFF=0 or 1, 1 is default. [Changed] Length of DMIS Editor is increased and DMIS code line link is also increased

78 [New] When Create Feature is selected, a list of features (object select) appears on a pop-up box. Nominal Editor opens automatically after selecting a feature. Three options (Nom Only, Quick Meas & Measure) are added to write DMIS program for nominal & measurement in nominal editor box. This options are VMS. INI set required. [PROCESS] ADVANCED_CAD=1 Default is 1. Construction [New] Construction feature can use raw points. It is useful if want to create 2 different features in same measurement. [Improved] Displaying complete message when using my icon on My Toolbar is optional. [SYS] MACMSG=0 [1], Default is 0. Report [Improved] Overwrite True Position value if using MMC on Overwrite mode in Met-Reporter. It only checks label instead of label & tolzone value due to various tolzone for MMC. Tolerance [Added] Circle and Arc are available in Tolerance Profile as PROFL. It works with DMIS program as well. The profile error includes position deviation and form error

79 EZ-Tool [Improved] Clear Surface Box UI moves to EzTool. Box on/off command and update current position icons are added. SNSET/CLRSRF, AUTOCLS, OFF

80 [New] Safe postions (red spots on the figure) to avoid collision is automatically written in the DMIS program if the Write GOTO check button is checked in the Clear Surface Box

81 UI [Improved] Update current position button is added in Machine Move dialog box only in the Absolute tab

82 VMS.INI [PROCESS] LEGACY_2PT_OFFSET=1 Options : 0=Offset calculation with new method 1=Offset calculation with legacy method. ADVANCED_CAD=1 Options : 0=Legacy method for object selection. 1=Features are shown when slect Create Feature for object selection 1 is defualt. [GEOMETRY] COORD_NOM_UPDATE=1 Options : 0=Nominal data updating off 1= Nominal data updating when translate 0 is default. [SENSOR] DROP_PICK_PRB=1 Options : 0=Drop & Pick off 1=Drop & Pick when exchange Touch Vision DOCK_ANG_A=90 DOCK_ANG_B=180 This orientation of probe is useful for layout machine such as Minerva when probe mount parallel to Y column. CALIB_AUTO_MODE=0 Options : 0=Change AUTO mode 1=Keep PROG mode after sensor calibration. 1 is default [SYS] MACMSG=0 Options : 0=Not show complete message when finish macro program through My Toolbar. 1=Show Message Defualt is 0. [LEARNMODE] LEARNOFF = 0 Options : 0=Keep Learn on or off status 1=Learn off when runing a program. 1 is defualt

83 DMIS Syntax [New] DME syntax for file open dialog box. It can be used to avoid typing the path & file name with TEXT/QUERY syntax. DECL/CHAR,80,sFileName CALL/EXTERN, DME, 'OPENDLG', sfilename [New] DME syntax for Write Private Profile String in a file. It is useful and easy write a parameter in to specific file. sp1:section, sp2:parameter, sp3:value, sp4:file path & name. CALL/EXTERN, DME, 'V3DSETPPS',sP1,sP2,sP3,sP4 CALL/EXTERN, DME, 'V3DSETPPS',PROCESS, DISPLAY, ON, C:\DATA\Param.ini Resulting lines in Param.ini after running the above code: [PROCESS] DISPLAY=ON It is useful to use V3DGETPPS to read a parameter value from the file, if parameters have sectionised. [New] DME syntax for creating Met-Reporter file name with current date & time. UI button is Write DMIS Filename Time Stamp in Met-Repoter menu. CALL/EXTERN, DME, 'VMRTATSV','C:\ResultFile\Housing\Report\Housing'. File name is Housing_ _ MRP after runing the DME code. [Changed] DMIS code line link ($) uses longer than 135 character instead of 80 character due to increased use of wide screens. [New] Best Fit under Construction can use raw points. One feature s raw points can be used to create another feature. CONST/BF,F(CY1),FA(CR1)[1,4],FA(CR2)[1,4] CONST/BF,F(CR1),FA(AR1)[1,3]

Virtual DMIS Elevating Metrology to a Higher Level

Virtual DMIS Elevating Metrology to a Higher Level Virtual DMIS Elevating Metrology to a Higher Level Active Matrix Repurpose CAD data independent of CMM software Runs as a standalone application Direct Import of CATIA V4 and V5, ProE, Unigraphics, Parasolids,

More information

Geomet operates in four different levels designed to match your inspection needs. These levels are known as:

Geomet operates in four different levels designed to match your inspection needs. These levels are known as: Helmel Engineering Products, Inc. 6520 Lockport Road Niagara Falls, NY 14305 (800) BEST-CMM (716) 297-8644 (716) 297-9405 fax www.helmel.com www.geomet-cmm-software.com Geomet Version Comparison Chart

More information

Shortcut and Hot keys available from the main Geomet screen.

Shortcut and Hot keys available from the main Geomet screen. Editor Keys Function Description Junior 101 GeoPlus 301 GeoCad DCC Future Development The Bisector routine determines the bisecting or symmetry a Bisector feature between the last two compatible features

More information

FARO Scanning Plugin

FARO Scanning Plugin FARO Scanning Plugin For compatibility with Geomagic products, see Release Notes for. Document version E. Copyright 2005, Raindrop Geomagic, Inc. The FARO scanner is a seven-axis measurement device from

More information

FARO Scanning Plugin

FARO Scanning Plugin FARO Scanning Plugin for Geomagic Studio 6 service release 4, Geomagic Qualify 6 service release 2, and Geomagic Qualify 7 Document version B Copyright 2004, Raindrop Geomagic, Inc. The FARO scanner is

More information

Perceptron Plugin. Activating the Perceptron Plugin

Perceptron Plugin. Activating the Perceptron Plugin Perceptron Scanner Plugin for compatibility with Geomagic products, see Release Notes for Geomagic Document version D. Copyright 2005, Raindrop Geomagic, Inc. Plugins > Perceptron is the interface in Geomagic

More information

StickFont v2.12 User Manual. Copyright 2012 NCPlot Software LLC

StickFont v2.12 User Manual. Copyright 2012 NCPlot Software LLC StickFont v2.12 User Manual Copyright 2012 NCPlot Software LLC StickFont Manual Table of Contents Welcome... 1 Registering StickFont... 3 Getting Started... 5 Getting Started... 5 Adding text to your

More information

User Manual. Universal CMM Server

User Manual. Universal CMM Server Universal CMM Server 6/5/2016 1. GUI..... 3 1.1. Main screen... 3 1.1.1. Tabs... 4 1.1.1.1. Command... 4 1.1.1.2. Tools... 5 1.1.1.3. Tool Properties... 7 1.1.1.4. Errors tab... 7 1.1.2. Right pane...

More information

Strategy. Using Strategy 1

Strategy. Using Strategy 1 Strategy Using Strategy 1 Scan Path / Strategy It is important to visualize the scan path you want for a feature before you begin taking points on your part. You want to try to place your points in a way

More information

Powered By Innovation. Moving Metrology to the Future

Powered By Innovation. Moving Metrology to the Future Powered By Innovation Moving Metrology to the Future Single Page Software Format USER INTERFACE LAYOUT Dynamic Toolbar: Guiding function determination SMART Toolbar: It is user programmable. Drag and drop

More information

501, , 1052, , 1602, 1604 EXCEL EXCEL 1602UC EXCEL 1052UC EXCEL 501HC. Micro-Vu Corporation. Precision Measurement Systems

501, , 1052, , 1602, 1604 EXCEL EXCEL 1602UC EXCEL 1052UC EXCEL 501HC. Micro-Vu Corporation. Precision Measurement Systems 501, 502 1051, 1052, 1054 1601, 1602, 1604 1602UC 1052UC 501HC Precision Measurement Systems 501, 502 1051, 1052, 1054 1601, 1602, 1604 Excel 501 HM/HC Excel 502 HM/HC Excel 501 Excel 502 Scale Resolution

More information

BuildIT Release Notes

BuildIT Release Notes BuildIT 2016.5 Release Notes Installation Notes In order to install all the associated drivers properly, right-click on the setup file and select Run as administrator. This installation does not overwrite

More information

2D MANUAL. is a manual 2D vision system with a massive difference.

2D MANUAL. is a manual 2D vision system with a massive difference. vision systems 2D MANUAL is a manual 2D vision system with a massive difference. VuMaster Due to the newly patented Colourmap scale system, the VuMaster does not have a conventional stage or encoders just

More information

Automatically search for holes and locate hole centers to offset measurement

Automatically search for holes and locate hole centers to offset measurement New Tools in PolyWorks 2018 InnovMetric Software Inc. All rights reserved. PolyWorks is a registered trademark of InnovMetric Software Inc. InnovMetric, PolyWorks Inspector, PolyWorks Modeler, PolyWorks

More information

Image Measuring Instrument

Image Measuring Instrument EASY QUICK ACCURATE SAVE Time & Cost Improved efficiency & accuracy L26 All new Image Measuring Instrument Top Series come with new innovative design in structural quality, functionality, and accuracy,

More information

StickFont Editor v1.01 User Manual. Copyright 2012 NCPlot Software LLC

StickFont Editor v1.01 User Manual. Copyright 2012 NCPlot Software LLC StickFont Editor v1.01 User Manual Copyright 2012 NCPlot Software LLC StickFont Editor Manual Table of Contents Welcome... 1 Registering StickFont Editor... 3 Getting Started... 5 Getting Started...

More information

Table of Contents General Use... 4 Feature Measurement & Construction... 4 PATERN... 4 PARALLEL PLANE... 4 PLANE... 4 CURVE... 5 BEST FIT...

Table of Contents General Use... 4 Feature Measurement & Construction... 4 PATERN... 4 PARALLEL PLANE... 4 PLANE... 4 CURVE... 5 BEST FIT... Release Notes Table of Contents General Use... 4 Feature Measurement & Construction... 4 PATERN... 4 PARALLEL PLANE... 4 PLANE... 4 CURVE... 5 BEST FIT... 5 Coordinate Systems... 6 Slot... 6 User Interface...

More information

AV300 VIDEO MEASURING SYSTEM.

AV300 VIDEO MEASURING SYSTEM. VIDEO MEASURING SYSTEM www.starrett-precision.co.uk 2 Starrett - Total Solution Provider Contents Page With Starrett Metrology products, the system is only a part of the whole package. From application

More information

Exercise Guide. Published: August MecSoft Corpotation

Exercise Guide. Published: August MecSoft Corpotation VisualCAD Exercise Guide Published: August 2018 MecSoft Corpotation Copyright 1998-2018 VisualCAD 2018 Exercise Guide by Mecsoft Corporation User Notes: Contents 2 Table of Contents About this Guide 4

More information

Highlights Metrosoft CM 3.60

Highlights Metrosoft CM 3.60 Highlights Metrosoft CM 3.60 Highlights, new functions and improvements for Metrosoft CM 3.60 Please note: The complete CM 3.60 functions and their description is available in the release notes. 1. 3D

More information

Perceptron Scan Plugin 7.0

Perceptron Scan Plugin 7.0 Perceptron Scan Plugin 7.0 For compatibility with Geomagic products, see Release Notes for Geomagic Perceptron Plugin 7.0. Copyright 2004, Raindrop Geomagic, Inc. Plugins > Perceptron is the interface

More information

Verisurf Analysis. Verisurf Analysis 1

Verisurf Analysis. Verisurf Analysis 1 Verisurf Analysis 1 Verisurf Analysis ANALYSIS MENU... 2 TUTORIAL... 2 BEFORE YOU START ANALYSIS... 9 ANALYZE... 9 GROW... 9 SHRINK... 9 ANALYSIS SETTINGS... 12 DEFINING THE PROBE RADIUS... 22 INSPECTION

More information

COMPUTER AIDED FIXTURING

COMPUTER AIDED FIXTURING COMPUTER AIDED FIXTURING by Itaca srl www.itaca-sw.it USER GUIDE Version 1.01 1 Introduction...2 2 Functional Overview...2 3 Components...2 3.1 Design...3 3.1.1 Toolbar Functions...3 3.1.2 The Component

More information

VTube-LASER Quick Start Guide for FARO QUANTUM from a Traditional Tube Print

VTube-LASER Quick Start Guide for FARO QUANTUM from a Traditional Tube Print VTube-LASER Quick Start Guide for FARO QUANTUM from a Traditional Tube Print This guide shows how to setup VTube-LASER from a tube print and then measure and qualify demo tube 4 using a FARO ScanArm. A

More information

Keynote 08 Basics Website:

Keynote 08 Basics Website: Website: http://etc.usf.edu/te/ Keynote is Apple's presentation application. Keynote is installed as part of the iwork suite, which also includes the word processing program Pages and the spreadsheet program

More information

CAMIO7 Multi-sensor CMM software

CAMIO7 Multi-sensor CMM software Ryf AG Bettlachstrasse 2 2540 Grenchen tel 032 654 21 00 fax 032 654 21 09 www.ryfag.ch CAMIO7 Multi-sensor CMM software Productivity-focused metrology software for tactile and 3D laser CMM inspection

More information

Insight: Measurement Tool. User Guide

Insight: Measurement Tool. User Guide OMERO Beta v2.2: Measurement Tool User Guide - 1 - October 2007 Insight: Measurement Tool User Guide Open Microscopy Environment: http://www.openmicroscopy.org OMERO Beta v2.2: Measurement Tool User Guide

More information

Release Highlights for BluePrint-PCB Product Version 3.0

Release Highlights for BluePrint-PCB Product Version 3.0 Release Highlights for BluePrint-PCB Product Version 3.0 Introduction BluePrint V3.0 Build 568 is a rolling release, containing defect fixes for 3.0 functionality. Defect fixes for BluePrint V3.0 Build

More information

Geomet. User Guide. Version 6.66 December Covering: Geomet 101, Geomet 101+, Geomet 301. Helmel Engineering Products, Inc

Geomet. User Guide. Version 6.66 December Covering: Geomet 101, Geomet 101+, Geomet 301. Helmel Engineering Products, Inc Geomet User Guide Version 6.66 December 2005 Covering: Geomet 101, Geomet 101+, Geomet 301 Helmel Engineering Products, Inc 6520 Lockport Road Niagara Falls, NY 14305 (716) 297-8644 (716) 297-9405 fax

More information

Chapter Eight: Editing a Part Program

Chapter Eight: Editing a Part Program Chapter Eight: Editing a Part Program Introduction PC-DMIS's main purposes are to allow you to create, edit, and execute part programs with ease. This chapter discusses using the Edit menu (with other

More information

CRITERION Vantage 3 Admin Training Manual Contents Introduction 5

CRITERION Vantage 3 Admin Training Manual Contents Introduction 5 CRITERION Vantage 3 Admin Training Manual Contents Introduction 5 Running Admin 6 Understanding the Admin Display 7 Using the System Viewer 11 Variables Characteristic Setup Window 19 Using the List Viewer

More information

Central Management Software for NVR-915 / NVR-1615 CV5-M256

Central Management Software for NVR-915 / NVR-1615 CV5-M256 Central Management Software for NVR-915 / NVR-1615 Table of Contents Chapter 1. Main Console... 4 1.1 Tool Bar... 4 1.2 NVR List... 5 1.3 Division List... 7 1.4 Group List... 9 1.5 PTZ Panel...11 1.6 Operation

More information

LinkMotion and CorelDraw 9, 10, 11, 12, X3, X4, X5, X6, X7 and X8:

LinkMotion and CorelDraw 9, 10, 11, 12, X3, X4, X5, X6, X7 and X8: LinkMotion and CorelDraw 9, 10, 11, 12, X3, X4, X5, X6, X7 and X8: After you install LinkMotion software and set up all settings launch CorelDraw software. Important notes: Solustan s LinkMotion driver

More information

Motic Images Plus 3.0 ML Software. Windows OS User Manual

Motic Images Plus 3.0 ML Software. Windows OS User Manual Motic Images Plus 3.0 ML Software Windows OS User Manual Motic Images Plus 3.0 ML Software Windows OS User Manual CONTENTS (Linked) Introduction 05 Menus and tools 05 File 06 New 06 Open 07 Save 07 Save

More information

Tutorial 1 Engraved Brass Plate R

Tutorial 1 Engraved Brass Plate R Getting Started With Tutorial 1 Engraved Brass Plate R4-090123 Table of Contents What is V-Carving?... 2 What the software allows you to do... 3 What file formats can be used?... 3 Getting Help... 3 Overview

More information

User Guide. mk Config

User Guide. mk Config User Guide mk Config mk Config Register 1.1. CD-Start 4 1.2. Installation 5 1.3. Start 6 1.4. Layout of user interface and functions 7 1.4.1. Overview 7 1.4.2. Part buttons 8 1.4.3. Menus 9 1.4.3.1. Export

More information

Conversational Programming for 6000M, 5000M CNC

Conversational Programming for 6000M, 5000M CNC Conversational Programming for 6000M, 5000M CNC www.anilam.com P/N 70000486F - Contents Section 1 - Introduction Section 2 - Conversational Mode Programming Hot Keys Programming Hot Keys... 2-1 Editing

More information

Integrated Metrology Suite for Effort Free Measurement. AxelSystems AXEL 7.

Integrated Metrology Suite for Effort Free Measurement. AxelSystems AXEL 7. AxelSystems Integrated Metrology Suite for Effort Free Measurement AXEL 7 www.axelsystems.com ADVANCED FEATURES MAKE AXEL EASY TO USE Work smarter and faster with intuitive graphic interface. Our already

More information

What s New in CreativeStudio Version 3.0.0

What s New in CreativeStudio Version 3.0.0 GAMMILL, INC. 1452 Gibson St West Plains, MO 65775 PH: 800-659-8224 FAX: 417-256-5757 www.gammill.com www.statlerstitcher.com What s New in CreativeStudio Version 3.0.0 Gammill is pleased to announce CreativeStudio

More information

Electrical 3D Design & Documentation

Electrical 3D Design & Documentation Electrical 3D Design & Documentation Page 1 Overview Conventions User Tasks Using Electrical 3D Design & Documentation Entering the Electrical Assembly Design Workbench Entering the Electrical Part Design

More information

Steinbichler T-Scan Plugin

Steinbichler T-Scan Plugin Steinbichler T-Scan Plugin For compatibility with Geomagic products, see Release Notes for Steinbichler T-Scan Plugin. Document version A. Copyright 2006, Geomagic, Inc. Plugins > T-Scan for Leica or Plugins

More information

Section 3 Formatting

Section 3 Formatting Section 3 Formatting ECDL 5.0 Section 3 Formatting By the end of this Section you should be able to: Apply Formatting, Text Effects and Bullets Use Undo and Redo Change Alignment and Spacing Use Cut, Copy

More information

FactoryLink 7. Version 7.0. Client Builder Reference Manual

FactoryLink 7. Version 7.0. Client Builder Reference Manual FactoryLink 7 Version 7.0 Client Builder Reference Manual Copyright 2000 United States Data Corporation. All rights reserved. NOTICE: The information contained in this document (and other media provided

More information

LIGHTCONVERSE TOOLS Interface Overview

LIGHTCONVERSE TOOLS Interface Overview MANUAL 1 Contents Contents... 1 LIGHTCONVERSE TOOLS Interface Overview... 2 Tool Manager... 3 Mouse... 4 Mouse Control Operation:... 4 3D Space Area... 4 Modes... 5 Balance Calculator in Warehouse Mode...

More information

What's New in CAMWorks For Solid Edge-2015

What's New in CAMWorks For Solid Edge-2015 Contents (Click a link below or use the bookmarks on the left) What s New in CAMWorks For Solid Edge 2015-SP0 2 Supported Platforms 2 Resolved CPR s document 2 General... 3 CAMWorks Virtual Machine for

More information

NC Manufacturing Verification

NC Manufacturing Verification NC Manufacturing Verification Page 1 Preface Using This Guide Where to Find More Information Conventions What's New? User Tasks Accessing NC Manufacturing Verification Comparing the Machined Stock Part

More information

Ch 22 Inspection Technologies

Ch 22 Inspection Technologies Ch 22 Inspection Technologies Sections: 1. Inspection Metrology 2. Contact vs. Noncontact Inspection Techniques 3. Conventional Measuring and Gaging Techniques 4. Coordinate Measuring Machines 5. Surface

More information

CHAPTER 1 COPYRIGHTED MATERIAL. Getting to Know AutoCAD. Opening a new drawing. Getting familiar with the AutoCAD and AutoCAD LT Graphics windows

CHAPTER 1 COPYRIGHTED MATERIAL. Getting to Know AutoCAD. Opening a new drawing. Getting familiar with the AutoCAD and AutoCAD LT Graphics windows CHAPTER 1 Getting to Know AutoCAD Opening a new drawing Getting familiar with the AutoCAD and AutoCAD LT Graphics windows Modifying the display Displaying and arranging toolbars COPYRIGHTED MATERIAL 2

More information

Chapter 1 : Getting Started with Integrity... Chapter 2 : Interface Layout... Chapter 3 : Navigation... Chapter 4 : Printing...

Chapter 1 : Getting Started with Integrity... Chapter 2 : Interface Layout... Chapter 3 : Navigation... Chapter 4 : Printing... .0 User s Manual Table of Contents Chapter : Getting Started with Integrity... Chapter : Interface Layout... Chapter : Navigation... Chapter : Printing... Chapter : Quick Search and Results Pane... Results

More information

Software Operations Manual

Software Operations Manual Software Operations Manual Version 5.0 System Requirements PC with 1GHz or higher, Intel Pentium Processor or compatible Microsoft Windows XP Professional or Vista Business Edition Microsoft.NET framework

More information

Selective Space Structures Manual

Selective Space Structures Manual Selective Space Structures Manual February 2017 CONTENTS 1 Contents 1 Overview and Concept 4 1.1 General Concept........................... 4 1.2 Modules................................ 6 2 The 3S Generator

More information

University of Sunderland. Microsoft Word 2007

University of Sunderland. Microsoft Word 2007 Microsoft Word 2007 10/10/2008 Word 2007 Ribbons you first start some of the programs in 2007 Microsoft Office system, you may be surprised by what you see. The menus and toolbars in some programs have

More information

Process Eye Professional. Recall

Process Eye Professional. Recall Process Eye Professional Recall Process Eye Professional Recall User Manual SP104010.101 August 2005 As part of our continuous product improvement policy, we are always pleased to receive your comments

More information

Conversational Programming for 6000i CNC

Conversational Programming for 6000i CNC Conversational Programming for 6000i CNC www.anilam.com P/N 634 755-22 - Contents Section 1 - Introduction Section 2 - Conversational Mode Programming Hot Keys Programming Hot Keys... 2-1 Editing Keys...

More information

Tetra4D Reviewer. Version 5.1. User Guide. Details on how to use Tetra4D Reviewer.

Tetra4D Reviewer. Version 5.1. User Guide. Details on how to use Tetra4D Reviewer. Tetra4D Reviewer Version 5.1 User Guide Details on how to use Tetra4D Reviewer. ii Contents Chapter 1: Work area... 7 Looking at the work area... 7 Toolbars and toolbar presets... 8 About toolbars and

More information

Getting Started with ShowcaseChapter1:

Getting Started with ShowcaseChapter1: Chapter 1 Getting Started with ShowcaseChapter1: In this chapter, you learn the purpose of Autodesk Showcase, about its interface, and how to import geometry and adjust imported geometry. Objectives After

More information

TESSERA PROCESSOR 1.3.0

TESSERA PROCESSOR 1.3.0 TESSERA PROCESSOR 1.3.0 RELEASE NOTES Previous public release: 1.2.5 Included panel firmware release: 1.3 13 Jan 2017 NEW SUB FIXTURE WORKFLOW In 2014 we launched our unique sub fixtures feature, for use

More information

VisualCAM 2018 for SOLIDWORKS-TURN Quick Start MecSoft Corporation

VisualCAM 2018 for SOLIDWORKS-TURN Quick Start MecSoft Corporation 2 Table of Contents Useful Tips 4 What's New 5 Videos & Guides 6 About this Guide 8 About... the TURN Module 8 Using this... Guide 8 Getting Ready 10 Running... VisualCAM for SOLIDWORKS 10 Machining...

More information

CNC Programming Simplified. EZ-Turn / TurnMill Tutorial.

CNC Programming Simplified. EZ-Turn / TurnMill Tutorial. CNC Programming Simplified EZ-Turn / TurnMill Tutorial www.ezcam.com Copyright Notice This manual describes software that contains published and unpublished works of authorship proprietary to EZCAM Solutions,

More information

Dolphin PartMaster Wire EDM

Dolphin PartMaster Wire EDM Dolphin PartMaster Wire EDM Copyright 2000-2017 Dolphin CADCAM Systems Ltd. This document is copyrighted and all rights are reserved. This document may not, in whole or in part, be copied or reproduced

More information

NC Manufacturing Verification

NC Manufacturing Verification NC Manufacturing Verification Overview Conventions What's New? User Tasks Accessing NC Manufacturing Verification Comparing the Machined Stock Part and the Design Part Pick Point Analysis in Video Mode

More information

Copyright 2015 Integrated Environmental Solutions Limited. All rights reserved.

Copyright 2015 Integrated Environmental Solutions Limited. All rights reserved. Tabular Room Data User Guide IES Virtual Environment Copyright 2015 Integrated Environmental Solutions Limited. All rights reserved. No part of the manual is to be copied or reproduced in any form without

More information

GDL Toolbox 2 Reference Manual

GDL Toolbox 2 Reference Manual Reference Manual Archi-data Ltd. Copyright 2002. New Features Reference Manual New Save GDL command Selected GDL Toolbox elements can be exported into simple GDL scripts. During the export process, the

More information

Navigator Software User s Manual. User Manual. Navigator Software. Monarch Instrument Rev 0.98 May Page 1 of 17

Navigator Software User s Manual. User Manual. Navigator Software. Monarch Instrument Rev 0.98 May Page 1 of 17 User Manual Navigator Software Monarch Instrument Rev 0.98 May 2006 Page 1 of 17 Contents 1. NAVIGATOR SOFTWARE 2. INSTALLATION 3. USING NAVIGATOR SOFTWARE 3.1 STARTING THE PROGRAM 3.2 SYSTEM SET UP 3.3

More information

VERO UK TRAINING MATERIAL. 2D CAM Training

VERO UK TRAINING MATERIAL. 2D CAM Training VERO UK TRAINING MATERIAL 2D CAM Training Vcamtech Co., Ltd 1 INTRODUCTION During this exercise, it is assumed that the user has a basic knowledge of the VISI-Series software. OBJECTIVE This tutorial has

More information

TRAINING SESSION Q2 2016

TRAINING SESSION Q2 2016 There are 8 main topics in this training session which focus on the Sketch tools in IRONCAD. Content Sketch... 2 3D Scene Background Settings... 3 Creating a new empty Sketch... 4 Foam with cut out for

More information

MS Word Professional Document Alignment

MS Word Professional Document Alignment MS Word Professional Document Alignment Table of Contents CHARACTER VS. PARAGRAPH FORMATTING...5 Character formatting...5 Paragraph Formatting...5 USING SHOW/HIDE TO REVEAL NON-PRINTING CHARACTERS...5

More information

When dragging out a marquee: Shift toggles the corner selection

When dragging out a marquee: Shift toggles the corner selection VECTORSCRIBE DYNAMIC CORNERS When dragging out a marquee: Esc cancels the marquee When dragging out a marquee: Shift toggles the corner selection When dragging out a marquee: Option+Alt adds corners to

More information

GraphWorX64 Productivity Tips

GraphWorX64 Productivity Tips Description: Overview of the most important productivity tools in GraphWorX64 General Requirement: Basic knowledge of GraphWorX64. Introduction GraphWorX64 has a very powerful development environment in

More information

Software Manual. Version: H BENCHTOP ROBOT SOFTWARE USER GUIDE Version H

Software Manual. Version: H BENCHTOP ROBOT SOFTWARE USER GUIDE Version H Software Manual Version: H6.1.1.292 BENCHTOP ROBOT SOFTWARE USER GUIDE Version H6.1.1.293 Software Manual Table of Contents SECTION 1: INTRODUCTION... 5 1.1 Introduction...6 1.2 Safety...6 1.3 New Features...6

More information

ECDL Module 6 REFERENCE MANUAL

ECDL Module 6 REFERENCE MANUAL ECDL Module 6 REFERENCE MANUAL Presentation Microsoft PowerPoint XP Edition for ECDL Syllabus Four PAGE 2 - ECDL MODULE 6 (USING POWERPOINT XP) - MANUAL 6.1 GETTING STARTED... 4 6.1.1 FIRST STEPS WITH

More information

DesignCAD 3D Max 22.1 Release Notes

DesignCAD 3D Max 22.1 Release Notes DesignCAD 3D Max 22.1 Release Notes December 2012 This update to DesignCAD offers the following improvements and fixes: BasicCAD: We have added some new Query/Change parameters to address missing functionality:

More information

Design and Print Instruction Manual

Design and Print Instruction Manual Diamond Design Design and Print Instruction Manual Contents Installation 1 Installing the Diamond Design Software 2-3 Installing the ORIGINAL Argox OS-214 printer drivers 4 Installing the EXCEL Argox OS-314

More information

Software User s Manual

Software User s Manual 1 Software User s Manual CONTENTS About the manual 2 Navigating the manual 3 CUSTOMIZING 4 Opening the control panel 4 Control panel overview 5 Calibrating the pen display 7 Adjusting pitch and phase (VGA

More information

Learning the Pro/ENGINEER Interface

Learning the Pro/ENGINEER Interface 2 Learning the Pro/ENGINEER Interface This chapter introduces the Pro/ENGINEER interface tools: the menus, the dashboards, the selection tools and the viewing controls. As you go through this chapter,

More information

GstarCAD Complete Features Guide

GstarCAD Complete Features Guide GstarCAD 2017 Complete Features Guide Table of Contents Core Performance Improvement... 3 Block Data Sharing Process... 3 Hatch Boundary Search Improvement... 4 New and Enhanced Functionalities... 5 Table...

More information

Piping Design. Site Map Preface Getting Started Basic Tasks Advanced Tasks Customizing Workbench Description Index

Piping Design. Site Map Preface Getting Started Basic Tasks Advanced Tasks Customizing Workbench Description Index Piping Design Site Map Preface Getting Started Basic Tasks Advanced Tasks Customizing Workbench Description Index Dassault Systèmes 1994-2001. All rights reserved. Site Map Piping Design member member

More information

PART I GravoStyle5-Laser Introduction

PART I GravoStyle5-Laser Introduction PART I GravoStyle5-Laser Introduction I. INTRO GravoStyle 5 Laser is designed is a component of GravoStyle5 for use with the Gravograph/New Hermes and other manufacturer Laser Engravers. Combined with

More information

CellaVision Proficiency Software

CellaVision Proficiency Software CellaVision Proficiency USER S MANUAL 2.3 CellaVision Proficiency Preface CellaVision is a trademark of CellaVision AB. All other trademarks used in this document are property of their respective owners.

More information

BoA Tools Page 1 / 31

BoA Tools Page 1 / 31 BoA Tools Page 1 / 31 Standard tools Overview 2 Work pane 3 3D-2D file Main palette 6 Layout Main Palette 9 Navigation tools 11 Workplane Palette 14 Cursor Palette 21 Numeric control 24 Selection by Criteria

More information

300S READOUTS REFERENCE MANUAL

300S READOUTS REFERENCE MANUAL 300S READOUTS REFERENCE MANUAL 300S Key Layout 1 Display Area 2 Soft keys 3 Power Indicator light 4 Arrow Keys: Use the UP/DOWN keys to adjust the screen contrast. 5 Axis Keys 6 Numeric Keypad 7 ENTER

More information

CROMWELLSTUDIOS. Content Management System Instruction Manual V1. Content Management System. V1

CROMWELLSTUDIOS. Content Management System Instruction Manual V1.   Content Management System. V1 Content Management System Instruction Manual V1 www.cromwellstudios.co.uk Cromwell Studios Web Services Content Management System Manual Part 1 Content Management is the system by which you can change

More information

Wizard 1000 REFERENCE MANUAL

Wizard 1000 REFERENCE MANUAL Wizard 1000 REFERENCE MANUAL W1000 Key Layout Display Area Axis Keys Numeric Keypad Clear key Soft keys Enter key Power Indicator light Arrow keys - Up/ Down arrow keys are also used to adjust the screen

More information

The Department of Construction Management and Civil Engineering Technology CMCE-1110 Construction Drawings 1 Lecture Introduction to AutoCAD What is

The Department of Construction Management and Civil Engineering Technology CMCE-1110 Construction Drawings 1 Lecture Introduction to AutoCAD What is The Department of Construction Management and Civil Engineering Technology CMCE-1110 Construction Drawings 1 Lecture Introduction to AutoCAD What is AutoCAD? The term CAD (Computer Aided Design /Drafting)

More information

DISK DEFRAG Professional

DISK DEFRAG Professional auslogics DISK DEFRAG Professional Help Manual www.auslogics.com / Contents Introduction... 5 Installing the Program... 7 System Requirements... 7 Installation... 7 Registering the Program... 9 Uninstalling

More information

Table of Contents. Product Overview 3 System Requirements 4 Installing MicroView 5 Managing Users & Groups 8

Table of Contents. Product Overview 3 System Requirements 4 Installing MicroView 5 Managing Users & Groups 8 User s Manual Table of Contents Product Overview 3 System Requirements 4 Installing MicroView 5 Managing Users & Groups 8 Add a new user 8 Modify Group Privilege 9 How to Add a new camera 10 Add a new

More information

Quantifying Motion in Three Dimensions with ProAnalyst

Quantifying Motion in Three Dimensions with ProAnalyst Date Published: March 2007 Revised: April 2011 Abstract This tutorial provides users with a step-by-step guide to performing an analysis with ProAnalyst 3-D Professional Edition. This lesson covers the

More information

COPYCAT NEW FANGLED SOLUTIONS 2/6/2009

COPYCAT NEW FANGLED SOLUTIONS 2/6/2009 1.0 INTRODUCTION 1.1 CopyCat is a unique wizard used with MACH3. It is not a stand alone program. This wizard will allow you to jog a machine around and create a Gcode file from the movement. 2.0 REQUIREMENTS

More information

Tutorial 3: Using the Waveform Viewer Introduces the basics of using the waveform viewer. Read Tutorial SIMPLIS Tutorials SIMPLIS provide a range of t

Tutorial 3: Using the Waveform Viewer Introduces the basics of using the waveform viewer. Read Tutorial SIMPLIS Tutorials SIMPLIS provide a range of t Tutorials Introductory Tutorials These tutorials are designed to give new users a basic understanding of how to use SIMetrix and SIMetrix/SIMPLIS. Tutorial 1: Getting Started Guides you through getting

More information

RIVA / Athena Pro-Series ECU

RIVA / Athena Pro-Series ECU RIVA / Athena Pro-Series ECU USING SOFTWARE (MAYA) Running Maya for First Time Once installed, Maya is available in the Start menu under Programs -> Maya, or from a desktop short cut, if created. The first

More information

SOFTWARE INSTRUCTIONS DIGITAL SPEAKER PROCESSOR DP-SP3

SOFTWARE INSTRUCTIONS DIGITAL SPEAKER PROCESSOR DP-SP3 SOFTWARE INSTRUCTIONS DIGITAL SPEAKER PROCESSOR DP-SP3 Thank you for purchasing TOA s Digital Speaker Processor. Please carefully follow the instructions in this manual to ensure long, trouble-free use

More information

DIGITAL AUDIO PROCESSOR

DIGITAL AUDIO PROCESSOR SOFTWARE SETUP MANUAL DIGITAL AUDIO PROCESSOR DP-K1 (Version 1.05) This book supports the following software versions. Firmware: Version 2.00 or later DP-K1 setting software: Version 2.00 or later [Instruction

More information

Customer Release Note

Customer Release Note Customer Release Note FOR Safran Risk v7.1.5 SP1 (Last update: June 19, 2017) Safran Software Solutions 1 Copyright 1997-2017 Safran Software Solutions as. All rights reserved. Notice Safran is a registered

More information

LAB # 2 3D Modeling, Properties Commands & Attributes

LAB # 2 3D Modeling, Properties Commands & Attributes COMSATS Institute of Information Technology Electrical Engineering Department (Islamabad Campus) LAB # 2 3D Modeling, Properties Commands & Attributes Designed by Syed Muzahir Abbas 1 1. Overview of the

More information

PRESETTER SP40. Pesaro, September 2013

PRESETTER SP40. Pesaro, September 2013 Pesaro, September 2013 1 PRESETTER SP40 TECHNICAL SPECIFICATIONS: AXIS DIMENSIONS: Diameter 600mm, Height XXXX mm MAIN STRUCTURE: Entirely made in C45 medium carbon steel it ensures greater strength and

More information

CostX 6.6 Release Notes

CostX 6.6 Release Notes CostX 6.6 Release Notes CostX 6.6 is the latest release in the Exactal range of world-class digital measurement and BIM-enabled estimating software. This release comes with a host of exciting new features

More information

QuickTutor. An Introductory SilverScreen Modeling Tutorial. Solid Modeler

QuickTutor. An Introductory SilverScreen Modeling Tutorial. Solid Modeler QuickTutor An Introductory SilverScreen Modeling Tutorial Solid Modeler TM Copyright Copyright 2005 by Schroff Development Corporation, Shawnee-Mission, Kansas, United States of America. All rights reserved.

More information

izoom Screen Magnifier/Reader

izoom Screen Magnifier/Reader USER MANUAL izoom Screen Magnifier/Reader Support Email: support@issist.com www.issist.com 2 Table of Contents 1.0 Installation 7 2.0 Starting/Closing izoom 8 3.0 Magnification 3.1 Enable / Disable 12

More information

DWG/DXF Export. Some attribute values in blocks weren't exporting correctly.

DWG/DXF Export. Some attribute values in blocks weren't exporting correctly. DesignCAD 3D Max 20.1 Release Notes Nov. 9, 2010 DesignCAD 3D Max 20.1 introduces the following fixes and changes: DWG/DXF Export. Sometimes arcs and elliptical arcs, when exported to dwg or dxf format,

More information

Huntron Workstation DMM Tutorial

Huntron Workstation DMM Tutorial Huntron Workstation DMM Tutorial HUNTRON WORKSTATION DMM TUTORIAL... 1 HUNTRON WORKSTATION DMM SOFTWARE TUTORIAL... 3 Huntron Workstation software 3 Installation Instructions 3 Installation of Additional

More information