24011 series, 3/2 Direct solenoid actuated poppet valve

Size: px
Start display at page:

Download "24011 series, 3/2 Direct solenoid actuated poppet valve"

Transcription

1 0 series, / > Port size: / (ISO G or NPT), NAMUR Interface > Add-on manual override or inductive limit switches on request > Main application: Single and double acting actuators > TÜV-approval based on type examination DGRL 0/68/EU and IEC 68, multichannel up to SIL ( years) > Suited for outdoor use under critical environment conditions. > Variable valve solenoid combination Technical features Medium: Compressed air, filtered, nonlubricated and dry. Other gase and liquid fluids on request. (Viscosity for gaseous or liquid fluids up to 0 mm /s) Operation: Direct solenoid operated poppet valve Operating pressure: bar ( psi) Orifice: 5 mm Flow: Gaseous fluids: 0 l/min Liquid fluids: Cv 0, Port size: G/, / NPT NAMUR Interface with integrated recirculation from the exhaust air to the acutator sping chamber Flow direction: Optional Mounting position: Any, but preferably with solenoid vertical Ambient/Media temperature: NBR: C ( F) FKM: C ( F) Water +95 C (+0 F) VMQ: C ( F) Depending on solenoid system Air supply must be dry enough to avoid ice formation at temperatures below + C (5 F). For outdoor installations must be protected all connections against the penetration of moisture and a solenoid with IP66 protection must be used! Materials: Body: Aluminium anodized (suitable for high humidity, sulphuric, sodium chloride or ammonia environments), brass.00 (Ms 58) or stainless steel.0 (6 L) Seal: FKM, NBR, VMQ Inner parts: stainless steel, brass Flow conversion: Cv US Gallon/min (water) = l/min (air) x 0,00 Kv m³/h (water) = l/min (air) x 0, Technical data Housing: Brass Symbol Port size Orifice (mm) Operating pressure (bar) (psi) Material Seat seal Manual override Test certificate IEC 68 0/68/EU Weight (kg) Drawing No. Solenoid group Model *) G/ NBR Not possible X 0,65 A + B 00 G/ NBR Push only X 0,70 A + B 007 G/ NBR Turn and lock 0,70 A + B 09 G/ NBR Not possible X X 0,65 A + B 09 G/ FKM Not possible X 0,65 A + B 06 G/ VQM Not possible X 0,65 A + B 05 G/ VQM Semi automatic X 0,70 A + B 05 / NPT NBR Not possible X X 0,65 A + B 08 / NPT NBR Push only X 0,70 A + B 08 / NPT NBR Turn and lock 0,70 A + B 06 / NPT NBR Semi automatic X 0,70 A + B 00 / NPT FKM Not possible X 0,65 A + B 0 / NPT VQM Not possible X 0,65 A + B 006 / NPT VQM Push only X 0,70 A + B 056 *) When ordering please indicate solenoid, voltage and current type (frequency). Particulary for valves with TÜV approval and attachment in plants based on safety standard IEC 65, taking into account to the operating and maintance instructions document 7. without notice, the specifications given in this document. (00-5h) 05 Norgren GmbH /7 en

2 0 series, / Housing: Stainless steel Symbol Port size Operating pressure (bar) Material Seat seal Manual override Test certificate IEC 68 0/68/EU Weight (kg) Drawing No. Solenoid group Model *) G/ NBR Not possible X X 0,65 A + B 086 G/ FKM Not possible 0,70 A 07 *) G/ FKM Semi automatic 0,70 A 070 *) G/ FKM Not possible 0,70 A 09 *) G/ VMQ Not possible X 0,65 A 055 *) / NPT NBR Push only X X 0,65 A + B 0 / NPT FKM Turn and lock 0,70 A + B 06 / NPT FKM Not possible X 0,65 A + B 057 / NPT FKM Not possible 0,65 A 07 *) / NPT VMQ Not possible X 0,65 A 068 *) G/ NAMUR NBR Without X,00 A + B 096 G/ NAMUR VQM Without,00 A 0 G/ NAMUR NBR Without X X,00 A + B 05 *) / NPT NAMUR NBR Without X X,00 A + B 058 *) Housing: Aluminium anodized Symbol Port size Operating pressure (bar) Material Seat seal Manual override Test certificate IEC 68 0/68/EU Weight (kg) Drawing No. Solenoid group Model *) G/ NAMUR NBR Without X X 0,55 A + B 09 G/ NAMUR NBR Without X X 0,55 A + B 06 *) G/ NAMUR NBR Without 0,70 5 A + B 05 *5) / NPT NAMUR NBR Without X X 0,55 A + B 055 G/ NAMUR VQM Without X 0,55 A + B 0 G/ NAMUR NBR Without X X 0,55 A + B 009 *) *) When ordering please indicate solenoid, voltage and current type (frequency). *) Complete stainless steel version *) Port P in flange according to VDI/VDE 85 for attachment of positioners or to interlinking plate (see data sheet N/en ) *) Free of non-ferrous metals *5) Proximity switch Particulary for valves with TÜV approval and attachment in plants based on safety standard IEC 65, taking into account to the operating and maintance instructions document 7. en without notice, the specifications given in this document. (00-5h) 05 Norgren GmbH /7

3 0 series, / Solenoids group A, standard voltages Power consumption V d.c. 0 V a.c. (W) (VA) Rated current V d.c. 0 V a.c. (m A) (m A) Protection class IP/NEMA 6,9 70 IP65 (with connector) 7, 75 IP65 (with connector) Ex-Protection (ATEX-Category) Temperature Ambient/ Media ( C) Media: +80 max Media: +80 max 8,9 69 IP Media: +0 0,0 IP Media: +0 8,9 69 IP Media: +0 0,0 IP Media: +0 8,9 69 IP66 (with II G Ex eb mb IIC T/T5 Gb II D Ex tb IIIC T0 C Db T: T5: Electrical connection Connector DIN EN 7-80, Form A *) Connector DIN EN 7-80, Form A *) Terminals, cable gland Pg,5 Terminals, cable gland Pg,5 m cable, encapsulated in EP resin m cable, encapsulated in EP resin Drawing Circuit diagram Model No. No M0 x,5 *) ,0 IP66 (with II G Ex eb mb IIC T/T5 Gb II D Ex tb IIIC T0 C Db T: T5: M0 x,5 *) ,9 69 IP66 (with II G Ex d mb IIC T/T6 Gb II G Ex e mb IIC T/T6 Gb II D Ex tb IIIC T0 C Db T: T6: / NPT *) ,0 IP66 (with II G Ex d mb IIC T/T6 Gb II G Ex e mb IIC T/T6 Gb II D Ex tb IIIC T0 C Db T: T6: / NPT *) ,9 69 IP66 (with II G Ex d mb IIC T/T6 Gb II G Ex e mb IIC T/T6 Gb II D Ex tb IIIC T0 C Db T: T6: M0 x,5 *) ,0 IP66 (with II G Ex d mb IIC T/T6 Gb II G Ex e mb IIC T/T6 Gb II D Ex tb IIIC T0 C Db T: T6: M0 x,5 *) ,9 69 IP66 (with II G Ex mb d IIC T/T6 II G Ex mb e II T/T6 T: T6: M0 x,5 *) ,0 IP66 (with II G Ex mb d IIC T/T6 II G Ex mb e II T/T6 T: T6: M0 x,5 *) ,6 567 x Cl. I, Div., Gr. A - D Cl. II/III, Div., Gr. E - G TC (60 C) 5,7 68 x Cl. I, Div., Gr. A - D Cl. II/III, Div., Gr. E - G TC (60 C) Flying leads length 60 mm Flying leads length 60 mm Standard voltages (±0%) V d.c., 0 V a.c., other voltages on request. Design according to VDE 0580, EN 0/08. 00% duty cycle. *) Connector/cable gland is not scope of delivery, see table»accessories«attention: The protection class for coil series 6xx and 8xx is determined by the choice of cable gland. Example: if an ATEX-certified cable gland is used that has Ex d type of protection, the solenoid will have the protection class Ex d mb; if a cable gland with Ex e type of protection is used, the solenoid will have protection class Ex e mb. Approvals Model Approvals Datasheet ATEX IECEx FM 8x CSA-LR N/en xx KEMA 98 ATEX 5 X IECEx KEM X N/en Approvals Model Approvals Datasheet ATEX IECEx 6xx PTB 0 ATEX 085 X IECEx PTB.009X N/en xx PTB 06 ATEX 05 X IECEx PTB X N/en /7 without notice, the specifications given in this document. (00-5h) 05 Norgren GmbH en

4 0 series, / Solenoids group B, standard voltages Power consumption V d.c. 0 V a.c. (W) (VA) Rated current V d.c. 0 V a.c. (m A) (m A) Protection class IP/NEMA 6,8 8 IP65 (with connector) 0,6 6 IP65 (with connector) Ex-Protection (ATEX-Category) Temperature Ambient/ Media ( C) Electrical connection Connector DIN EN 7-80, form A *) Connector DIN EN 7-80, form A *),9 6 IP Media: +0 5, IP Media: +0,9 6 IP Media: +0 5, IP Media: +0,9 6 IP66 (with II G Ex eb mb IIC T/T6 Gb II D Ex tb IIIC T0 C Db T: T6: Drawing Circuit diagram Model No. No Terminals, cable gland Pg,5 9 0 Terminals, cable 9 6 gland Pg,5 m cable, 9 encapsulated in EP resin m cable, 9 6 encapsulated in EP resin M0 x,5 *) , IP66 (with II G Ex eb mb IIC T/T6 Gb II D Ex tb IIIC T0 C Db T: T6: M0 x,5 *) 6 7 6,9 6 IP66 (with II G Ex d mb IIC T/T6 Gb II G Ex e mb IIC T/T6 Gb II D Ex tb IIIC T0 C Db T: T6: / NPT *) , IP66 (with II G Ex d mb IIC T/T6 Gb II G Ex e mb IIC T/T6 Gb II D Ex tb IIIC T0 C Db T: T6: / NPT *) 7 66,9 6 IP66 (with II G Ex d mb IIC T/T6 Gb II G Ex e mb IIC T/T6 Gb II D Ex tb IIIC T0 C Db T: T6: M0 x,5 *) , IP66 (with II G Ex d mb IIC T/T6 Gb II G Ex e mb IIC T/T6 Gb II D Ex tb IIIC T0 C Db T: T6: M0 x,5 *) ,9 69 x Cl. I, Div., Gr. A - D Cl. II/III, Div., Gr. E - G TC (60 C) 9,5 x Cl. I, Div., Gr. A - D Cl. II/III, Div., Gr. E - G TC (60 C) Flying leads length 60 mm Flying leads length 60 mm Standard voltages (±0%) V d.c., 0 V a.c., other voltages on request. Design according to VDE 0580, EN 0/08. 00% duty cycle. *) Connector/cable gland is not scope of delivery, see table»accessories«attention: The protection class for coil series 6xx and 8xx is determined by the choice of cable gland. Example: if an ATEX-certified cable gland is used that has Ex d type of protection, the solenoid will have the protection class Ex d mb; if a cable gland with Ex e type of protection is used, the solenoid will have protection class Ex e mb. Approvals Model Approvals Datasheet ATEX IECEx FM 7x, 8x CSA-LR N/en xx KEMA 98 ATEX 5 X IECEx KEM X N/en xx PTB 0 ATEX 085 X IECEx PTB.009X N/en en without notice, the specifications given in this document. (00-5h) 05 Norgren GmbH /7

5 0 series, / Partnumbers for international approval Land/Approval Coil/Code 8x xx 6xx 8xx Europa/ATEX Standard x x x International/IECEx Standard x x x China/NEPSI -0 x x Brasilien/INMETRO -0 x x Korea/KOSHA (only gas approval) -0 x x x Russland, Kasachstan & Weißrussland/TR-CU 0-0 x x x Indien/CCOE Standard x x Taiwan/ITRI Standard x x USA/FM Standard x Kanada/CSA Standard x Example: (Coil: 0; Voltage: V DC; Approval: TR-CU 0) Accessories Electrical connection Cable gland Protection class Ex e, Ex d (ATEX), Nickel plated brass/ Stainless steel Page 0 Ambient temperatur For solenoid Thread Cable ø (mm) Material Protection class (ATEX) limitation *7) Model xx M0 x,5 7,0,0 Plastic II G Ex e / II D Ex t See table xx M0 x,5 0,0,0 Plastic II G Ex e / II D Ex t See table xx M0 x,5 6,0,0 Plastic II G Ex e / II D Ex t See table xx M0 x,5 5,0 0,0 Plastic II G Ex e / II D Ex t See table xx M0 x,5 5,0 8,0 Nickel plated brass II G Ex e / II D Ex t xx M0 x,5 0,0,0 Nickel plated brass II G Ex d / II D Ex t xx / NPT 7,5,9 Nickel plated brass II G Ex d / II D Ex t xx, 8xx M0 x,5 9,0,0 Stainless steel.57 II G Ex e / II D Ex t xx, 8xx M0 x,5 7,0,0 Stainless steel.0 II G Ex d / II D Ex t xx, 8xx M0 x,5 0,0,0 Stainless steel.0 II G Ex d / II D Ex t *7) The limitation of the temperature range to the mentioned range is due to the self-heating of the solenoid. Connector DIN EN (form A) For solenoid x/6x x/7x Ambient temperatur limitation solenoid xx & *8) *8) T & Dust Ex: -5 C + 80 C T & Dust Ex: -0 C + 65 C T & Dust Ex: C T6: -5 C + 55 C T6: -0 C + 55 C T6: C T & Dust Ex: -5 C +65 C T & Dust Ex: -0 C + 6 C T & Dust Ex: C T5: -5 C + 55 C T5: -0 C + 55 C T5: C *8) Tested for the lower level of mechanical risk ( joule), an additional protection against impacts might be needed. /7 without notice, the specifications given in this document. (00-5h) 05 Norgren GmbH en

6 0 series, / Connector for proximity switch -pin, 90 -pin, 90 -pin, straight -pin, straight Silencer *9) Exhaust guard *0) Page Page 058 ( m cable, -core) 05 (5 m cable, -core) 056 (without cable) Page 057 ( m cable, -core) 05 (5 m cable, -core) Page Page Page 055 (without cable) C/S (/ NPT) 06 (G/, / NPT) M/S (G/) Add-on manual override *) Without detent with detent Manual Override The manual override is meant to be used for system testing. Upon de-energisation of the coil the valve returns to rest position by mechanical spring force (for testing only prior to commissioning). Page 8 Page *9) For indoors use *0) For outdoors use, opening pressure 0, bar *) Add on for NAMUR valves always possible, Inline on request Using the manual override with detent cancels the SIL-Approval! Semi automatic/manual reset Function: The valve does not switch after energisation of the coil. It will only operate if the reset button is being pushed. The valve will then, by means of the coil voltage, be held in its switching position even if the reset button is being released. It will return to rest position when the coil is being de-energised. Allowable voltage tolerance: +/- 0%. NAMUR accessories (G/ only) Throttle control plate *) Flange plate Yoke Mounting plate Quick exhaust module *) Page Page & Page (NAMUR single connection plate) (montage in combination with ) 0679 (NAMUR-rip use in combination with 06790) *) The throttle control plate 009 has a minimum flow rate for safety reason. *) Technical details see catalogue page en Page Page 065 (90 ) 08 en without notice, the specifications given in this document. (00-5h) 05 Norgren GmbH /7

7 0 series, / Drawings Valves Dimensions in mm Projection/First angle , ,5, ,5 6, ,5 9 G/ ø ø 9,5 7,5,5 6,5,5 6,5 6 7 Port size G/ or / NPT mm deep /7 without notice, the specifications given in this document. (00-5h) 05 Norgren GmbH en

8 0 series, / Dimensions in mm Projection/First angle 6,5 ø 0 M6 9 5,5 5 7,5 ø ø 9,5, ,5 9 ø ø 9,5 8 6,5 5,5 7,5 6,5,5 6,5 6 7 Port size G/ or / NPT mm deep Add-on manual override Without detent Model: With detent Model: ,5 Please note: add-on manual override for NAMUR valves provided only for commissioning and tests 9 8,5 9 9,5 9 ø 6 6, ,5, ,5 6,5, Proximity switch Technical features Supply voltage (Ub): 7, V d.c. Ripple: 5% Frequency of operating cycles: 000 Hz Protection class: IP68 Pressure-resistant: 0 bar (75 psi) Ambient temperature: C ( F) pnp Rv + Port size G/ or / NPT mm deep Proximity switch 6 Thread M x en without notice, the specifications given in this document. (00-5h) 05 Norgren GmbH /7

9 0 series, / Solenoids Weight: 0,7 kg 86,5 Weight: 0, kg 96,5 Dimensions in mm Projection/First angle 9 6,5 59 0,5 7 M6 x,5 8 0,5 8 M6 x, Weight: 0,6 kg 7 Weight: 0,7 kg 70,5 07 0,5,5 6, , Weight: 0,8 kg 9 Weight: 0,7 kg / NPT 5 0, ,5,5 0,5 6 0 Connector can be indexed by x90 ø 6 or (with spacer tube) M0 x,5 or / NPT Flying leads AWG 8 (60 mm long) 5 With cable gland, Pg,5 /7 without notice, the specifications given in this document. (00-5h) 05 Norgren GmbH en

10 0 series, / 0 Weight:, kg ø 6 M0 x, Circuit diagrams T T Cable gland A B C ø D Model C B A D C B only A D M0 x, ,0..., M0 x,5 0 0,0..., M0 x, ,0..., M0 x,5 0 9,5 5,0... 0, M0 x, ,0... 8, M0 x,5 7 9,0, / NPT ,5..., M0 x,5 6,5 7,5 9,0..., M0 x, ,0, M0 x,5 6 0,0, en without notice, the specifications given in this document. (00-5h) 05 Norgren GmbH /7

11 0 series, / NAMUR hole pattern (actuator side) NAMUR quick exhaust module for a better kv-value by exhaust see data sheet NAMUR interlinking plates in redundancy design for»safety exhausting«and»safety ventilating«see data sheet () Coding stud threaded 8 mm deep Accessories Silencer Exhaust guard Model: M/S, C/S Model: 06 Dimensions in mm Projection/First angle,5 8 6,5 0 ø / ø / Single connection plate Model: (x) Mounting plate Model: 065 (90 ) () G/ 9, ,5 0 ø 9,5 9 ø G/ ø 9 ø,5 () ,5 /7 without notice, the specifications given in this document. (00-5h) 05 Norgren GmbH en

12 0 series, / NAMUR slot Yoke Throttle control plate Model: 0679 Model: Model: 009 Dimensions in mm Projection/First angle 9,5 x , ,5 M 5 60 Quick exhaust module Typ: 08 5 G/8 8 0 G/8 ø 5.5 ø ø 5.5 G/ Flanged surface NAMUR or externally mounted valve Flanged surface NAMUR actuator Push-in threaded piece after plate mounting (to secure correct position) 8 mm deep 5 Flow regulator retrofittable en without notice, the specifications given in this document. (00-5h) 05 Norgren GmbH /7

13 0 series, / Connector 90, pin, with PUR cable 90, pin, without cable Dimensions in mm Projection/First angle 5 5 B B,5 0,5 Pg7 Pg7 ø 5 ø B ø 0 B 7 ø 5 ø 5 ø 0 B C ød ød F Wire x dim. Cable length (m) Weight (g) Model M x,5 5 7 x 0, mm M x,5 5 7 x 0, mm B C ød E F Weight Model (g) M x 0,5 0 Pg Straight, pin, with PUR cable Straight, pin, without cable 0 0,5 B C ød ød Wire x dim. Cable length (m) Weight (g) Model M x 0 5 x 0, mm M x 0 5 x 0, mm B C ød E Weight Model (g) M x 0,5 0 Pg Warning These products are intended for use in industrial compressed air and fluid systems only. Do not use these products where pressures and temperatures can exceed those listed under»technical features/data«. Before using these products with fluids other than those specified, for non-industrial applications, life-support systems, or other applications not within published specifications, consult IMI Precision Engineering, Norgren GmbH. Through misuse, age, or malfunction, components used in fluid power systems can fail in various modes. The system designer is warned to consider the failure modes of all component parts used in fluid power systems and to provide adequate safeguards to prevent personal injury or damage to equipment in the event of such failure. System designers must provide a warning to end users in the system instructional manual if protection against a failure mode cannot be adequately provided. System designers and end users are cautioned to review specific warnings found in instruction sheets packed and shipped with these products. Functional safety (SIL): Suitable for certain applications can only be evaluated through examination of each safety-related overall system with regard to the requirements of IEC 68/65. /7 without notice, the specifications given in this document. (00-5h) 05 Norgren GmbH en

21023, 21025, 2/2 Direct solenoid actuated poppet valves

21023, 21025, 2/2 Direct solenoid actuated poppet valves 03, 05, / > > Port size: G/4, G/ > > Working from 0 bar up > > Suitable for mediumhigh vacuum down to.33 0 - mbar l/s > > Compact design > > Valves and solenoids are ATEX approved. Additional international

More information

Series 95000, 2/2 Direct solenoid actuated poppet valve

Series 95000, 2/2 Direct solenoid actuated poppet valve > Port size: /4 (ISO G or NPT), G/ > Working from 0 bar up > Short switching times > Suited for fine vacuum down to,33 x 0 - mbar > For a.c. solenoid systems with integrated rectifier (40... 60 Hz) > Variable

More information

Material Seat seal. N/en

Material Seat seal. N/en 0 / poppet valves electromagnetic actuated, directly controlled G /, / NPT or flanged with NAMUR interface TÜV-approval based on IEC 6 8 Valves for safety systems up to SIL Standard NAMUR type - redundancy:

More information

95100, 2/2 (stainless steel) Direct solenoid actuated poppet valves

95100, 2/2 (stainless steel) Direct solenoid actuated poppet valves 9500, / (stainless steel) > > Port size: G/8, G/4, /4 NPT > > Working from 0 bar up > > Assembled free of oil and grease > > Suited for fine vacuum down to,33 0 - mbar > > For a.c. solenoid systems with

More information

Operating pressure (bar)

Operating pressure (bar) / poppet valves electromagnetic actuated, directly controlled G /4, /4 NPT, G /, / NPT or flanged with NAMUR Interface Main application: single operated actuators for plants Valves for safety systems up

More information

Operating pressure. N/en/en

Operating pressure. N/en/en 660, 8007 NAMUR /, / & / way spool valves electromagnetic actuated, indirectly controlled G / and NAMUR interface For single and double operated actuators Manual override with and without detent Simple

More information

97100 NAMUR series, 3/2 & 5/2 Indirect solenoid actuated spool valve

97100 NAMUR series, 3/2 & 5/2 Indirect solenoid actuated spool valve 9700 NAMUR series, / & / > > Port size: /4 (ISO G or NPT), NAMUR Interface > > Crossover-free switching > > Main application: Single and double acting actuators > > / way valve usable as / way valve >

More information

98015 series, 3/2 Direct solenoid actuated poppet valve

98015 series, 3/2 Direct solenoid actuated poppet valve 90 series, / > Port size: / & / (ISO G/NPT), NAMUR Interface > Main application: Single acting actuators > TÜV-approval based on type eamination DGRL 9//EG and IE 0, multichannel up to SIL > Optional add-on

More information

Operating pressure. N/en/en

Operating pressure. N/en/en 660, 8007 NAMUR /, / & / spool valves electromagnetic actuated, indirectly controlled G / and NAMUR interface For single and double operated actuators Manual override with and without detent Simple design

More information

80265 series, 3/2 Indirect solenoid actuated poppet valve

80265 series, 3/2 Indirect solenoid actuated poppet valve > > Port size: G/... G > > High flow rate > > Optionally air pilot operated > > High repeatability of switching time > > Variable valve solenoid combination Technical features Medium: Compressed air, filtered,

More information

97105 NAMUR, 3/2, 5/2 & 5/3 Indirect electromagnetic actuated spool valves

97105 NAMUR, 3/2, 5/2 & 5/3 Indirect electromagnetic actuated spool valves 970 NAMUR, /, / & / > > Port size: / or / ISO G/NPT > > Main application: single and double operated actuators > > TÜV-approval based on type examination DIN EN, DIN 9 and IEC 08 > > Valves for safety

More information

Operating pressure (bar) kv factor (m 3 /h) *3)

Operating pressure (bar) kv factor (m 3 /h) *3) / way poppet valves (stainless steel) electromagnetic actuated, directly controlled G /8, G /4 or /4 NPT Working from 0 bar up Assembled free of oil and grease Suited for fine vacuum down to,33 0 - mbar

More information

3/2 Directional control valves Direct solenoid operated poppet valves Internal thread G 1/2, 1/2 NPT or flanged with NAMUR interface

3/2 Directional control valves Direct solenoid operated poppet valves Internal thread G 1/2, 1/2 NPT or flanged with NAMUR interface 9805 / Directional control valves Direct solenoid operated poppet valves Internal thread G /, / NPT or flanged with NAMUR interface Main application: single operated actuators for plants TÜV-approval based

More information

Material pressure (bar) (Cv (US) kv x 1,2 Seat

Material pressure (bar) (Cv (US) kv x 1,2 Seat 00 / poppet valves electromagnetic actuated, directly controlled G /, / NPT or flanged with NAMUR Interface TÜV-approval based on IEC 6 08, DIN V Valves for safety systems up to SIL Solenoid valve also

More information

97105 Inline 3/2, 5/2 & 5/3 way spool valves electromagnetic actuated, indirectly controlled G1/4, 1/4 NPT, G1/2, 1/2 NPT

97105 Inline 3/2, 5/2 & 5/3 way spool valves electromagnetic actuated, indirectly controlled G1/4, 1/4 NPT, G1/2, 1/2 NPT 70 Inline 3/, / & /3 way spool valves electromagnetic actuated, indirectly controlled G/, / NPT, G/, / NPT Main application: single and double operated actuators TÜV-approval based on type examination

More information

Technical features. 12/ f. N/en

Technical features. 12/ f. N/en /, / & / way spool valves electromagnetic actuated, indirectly controlled G /, / NPT, G /, / NPT or flanged with NAMUR interface Main application: single and double operated actuators TÜV-approval based

More information

97105 Inline 3/2, 5/2 & 5/3 spool valves electromagnetic actuated, indirectly controlled G 1/4, 1/4 NPT, G 1/2, 1/2 NPT

97105 Inline 3/2, 5/2 & 5/3 spool valves electromagnetic actuated, indirectly controlled G 1/4, 1/4 NPT, G 1/2, 1/2 NPT 705 Inline 3/, 5/ & 5/3 spool valves electromagnetic actuated, indirectly controlled G /, / NPT, G /, / NPT For single and double operated actuators Valves for safety systems up to SIL (IEC 6508) Crossover-free

More information

Technical features. N/en

Technical features. N/en /, 5/ & 5/ spool valves electromagnetic actuated, indirectly controlled G /, / NPT, G /, / NPT or flanged with NAMUR interface For single and double operated actuators Exhaust air recirculation at way

More information

Flow. Flow. N/en

Flow. Flow. N/en / poppet valves electromagnetic actuated, directly controlled G /4 or /4 NPT Working from 0 bar up Short switching times Suited for fine vacuum down to, 0 - mbar For a.c. solenoid systems with integrated

More information

V87 series - Redundant valve manifold systems - Semi modular 1oo2 Safety, 2oo2 Availability and 2oo3 Safety and Availability

V87 series - Redundant valve manifold systems - Semi modular 1oo2 Safety, 2oo2 Availability and 2oo3 Safety and Availability V87 series - Redundant valve manifold systems - Semi modular oo Safety, oo Availability and oo Safety and Availability > > Semi modular design - Herion valves > > Stainless steel visual status indicators

More information

26360, 80207, 3/2, 5/2 & 5/3 Indirect solenoid actuated spool valves

26360, 80207, 3/2, 5/2 & 5/3 Indirect solenoid actuated spool valves 66, 87, /, 5/ & 5/ > > Port size: G/ & G/ > > Compact design > > Easily interchangeable solenoid > > tandard manual override > > ll valves available with Ex protected coils (TEX or other international

More information

/2 way indirect solenoid operated valves G 1/2, 1/2 NPT or flanged with NAMUR Interface

/2 way indirect solenoid operated valves G 1/2, 1/2 NPT or flanged with NAMUR Interface 9805 / way indirect solenoid operated valves G /, / NPT or flanged with NMUR Interface Main application: single operated actuators for plants Valves for safety systems up to SIL (IE 6508) dd-on manual

More information

26360, NAMUR. Technical data

26360, NAMUR. Technical data 66, 87 NAMUR /-, /- and / directional control valves Operation: elektromagnetic Indirectly controlled soft seal spool valves Port size: G/ NAMUR-Interface For single and double operated actuators Manual

More information

26360, Inline. Technical data. Ordering information See page 2. For connector plugs see page 2 and data sheets N/en /2 5/2.

26360, Inline. Technical data. Ordering information See page 2. For connector plugs see page 2 and data sheets N/en /2 5/2. 66, 87 Inline / and 5/ directional control valves NG 6 and Operation: elektromagnetic Indirectly controlled soft seal spool valves Port size: G /4 and G / For single and double operated actuators Manual

More information

6215L Inline & NAMUR series, 3/2 & 5/2 Indirect solenoid actuated spool valve

6215L Inline & NAMUR series, 3/2 & 5/2 Indirect solenoid actuated spool valve L Inline & NMUR series, / & / > Port size: / (ISO /NPT) or flanged with NMUR interface > Suited for outdoor use under critical environment conditions (see solenoid list) > Variable valve solenoid combination

More information

97105 NAMUR. Technical data. Ordering information and accessories See page 6 and 7

97105 NAMUR. Technical data. Ordering information and accessories See page 6 and 7 90 NAMUR /, / and / directional valves Actuation: electromagnetic Indirectly controlled soft seal spool valves Port size: G /, / NPT, G /, / NPT NAMUR-interface For single and double operated actuators

More information

98025 NAMUR 3/2 poppet valves electromagnetic actuated, indirectly controlled G 1/2, 1/2 NPT or flanged with NAMUR Interface

98025 NAMUR 3/2 poppet valves electromagnetic actuated, indirectly controlled G 1/2, 1/2 NPT or flanged with NAMUR Interface 9805 NMUR / poppet valves electromagnetic actuated, indirectly controlled G /, / NPT or flanged with NMUR Interface Main application: single operated actuators for plants Valves for safety systems up to

More information

VALVES Inline 3/2-, 5/2- & 5/3 Spool valves electromagnetic actuated, indirectly controlled G 1/4, 1/4 NPT, G 1/2, 1/2 NPT

VALVES Inline 3/2-, 5/2- & 5/3 Spool valves electromagnetic actuated, indirectly controlled G 1/4, 1/4 NPT, G 1/2, 1/2 NPT 975 Inline 3/-, 5/- & 5/3 Spool valves electromagnetic actuated, indirectly controlled G /, / NPT, G /, / NPT For single and double operated actuators Closed crossover design Add-on manual override Rectified

More information

97105 Inline, 3/2 & 5/2 Direct pneumatically actuated spool valves

97105 Inline, 3/2 & 5/2 Direct pneumatically actuated spool valves 9705 Inline, 3/ & 5/ > > : /... / (ISO G/NPT) > > Main application: single and double operated actuators > > Valves for safety systems multi-channel up to SIL 3 > > Crossover-free switching > > TÜV-approval

More information

3/2 Directional control valves Indirect controlled solenoid operated poppet valves Internal thread G1/2, 1/2 NPT or flanged with NAMUR interface

3/2 Directional control valves Indirect controlled solenoid operated poppet valves Internal thread G1/2, 1/2 NPT or flanged with NAMUR interface 9805 / Directional control valves Indirect controlled solenoid operated poppet valves Internal thread G/, / NPT or flanged with NMUR interface Main application: single operated process actuators TÜV-approval

More information

G 1/2 30,5 A Brass NBR 0,8 3,

G 1/2 30,5 A Brass NBR 0,8 3, 4/2 way poppet valves electromagnetic actuated, directly controlled /4 & /2 Working from 0 bar up Suitable for vacuum range down.33 0-2 mbar l/s Protection class : IP 65, Ex em, Ex d TEX approved (see

More information

HERION SERIES Indirect solenoid actuated spool valves

HERION SERIES Indirect solenoid actuated spool valves HERION SERIES Indirect solenoid actuated spool valves for single and double acting actuators with NAMUR interface /2, /2, /, NC/APB, G/, G/2 Valves for safety systems up to SIL (IEC 08) Crossover-free

More information

V88 series Redundant valve manifold systems - Semi modular 2oo2 Availability

V88 series Redundant valve manifold systems - Semi modular 2oo2 Availability oo Availability > > Semi modular design - Maxseal valves > > Stainless steel visual indicators and exhaust guards as standard > > able terminations inside coil housing > > International approvals > > Stainless

More information

V88 series Redundant valve manifold systems - Semi modular 1oo2 Safety, 2oo2 Availability and 2oo3 Safety and Availability

V88 series Redundant valve manifold systems - Semi modular 1oo2 Safety, 2oo2 Availability and 2oo3 Safety and Availability oo Safety, oo Availability and oo Safety and Availability > > Semi modular design - Maxseal valves > > Stainless steel visual indicators and exhaust guards as standard > > able terminations inside coil

More information

Flow. (l/min) (ms) N/en

Flow. (l/min) (ms) N/en 66, 87 Inline / & / spool valves electromagnetic actuated, indirectly controlled G / & G / For single and double operated actuators Manual override with and without detent imple design of soft seal spool

More information

97105 Inline direct pneumatically actuated 3/2 and 5/2 spool valves G 1/4.G1/2, 1/4 NPT 1/2 NPT

97105 Inline direct pneumatically actuated 3/2 and 5/2 spool valves G 1/4.G1/2, 1/4 NPT 1/2 NPT direct pneumatically actuated 3/ and 5/ spool valves G /.G/, / NPT / NPT For single and double operated actuators Valves for safety systems up to SIL () Crossover-free switching, switch-over function guaranteed

More information

ICO3S - 2/2, 3/2 or 5/2 poppet valves Electromagnetically actuated, direct solenoid operated

ICO3S - 2/2, 3/2 or 5/2 poppet valves Electromagnetically actuated, direct solenoid operated ICOS - /, / or / poppet valves > > Port size: /... / (ISO G / NPT) Namur or manifold > > Control of pneumatic or hydraulic operated equipment > > Direct acting solenoid valve > > High flow > > bar inlet

More information

21D Allfluid pressure switch, electromechanically actuated

21D Allfluid pressure switch, electromechanically actuated D > > 0,... 0, bar (0,... psi), G/, / NPT > > High accuracy > > High number of switching cycles > > Microswitch approved by UL and CSA > > Fixed or adjustable hysteresis > > Shock and vibration tested

More information

SPCH/ Big bottle blowing block

SPCH/ Big bottle blowing block > > Blowing block for linear and rotating blow moulding machines > > Digital position indicator - counter with four decade from 000.0 to 00.0 > > Best suited for PET bottles from 5 up to 30 litres (up

More information

SCVA08, SCVA10, SCVA20 & SCVA32, 3/2 Solenoid actuated safety valve

SCVA08, SCVA10, SCVA20 & SCVA32, 3/2 Solenoid actuated safety valve SCV0, SCV0, SCV & SCV, / > > Port size: /4, /, /4 and (ISO G, NPT) > > Range of sizes - DN, 0, and > > Redundant valve assembly, pneumatic self monitoring with integrated safety silencer > > Ensures safe

More information

ICO4S 2/2, 3/2 or 5/2 poppet valves electromagnetic actuated, directly controlled

ICO4S 2/2, 3/2 or 5/2 poppet valves electromagnetic actuated, directly controlled ICO4S /, / or 5/ poppet valves > > Port size: /4... /4 (ISO G/NPT) or manifold version > > Reliable and long life, ideal for a one time installation > > Direct acting solenoid valve for the control of

More information

Pneumatic Control/Feedback

Pneumatic Control/Feedback 897 /Feedback Type 897 can be combined with... Compact design Integrated pilot valve with manual override Internal control air routing Bright LED position indicator Automatic end position adjustment Type

More information

ISO*STAR (SXE, SXP) 5/2 & 5/3 Solenoid and pilot actuated glandless spool valves

ISO*STAR (SXE, SXP) 5/2 & 5/3 Solenoid and pilot actuated glandless spool valves *STR (SX, SXP) / & / > > Sub-base mounted, 99- s, or > > Specially coated glandless spool and sleeve for long trouble-free life > > Integral flow regulators available on and s for cylinder speed control

More information

Pneumatic Control/Feedback

Pneumatic Control/Feedback 897 /Feedback Type 897 can be combined with... Compact design Integrated pilot valve with manual override Internal control air routing Automatic end position adjustment With ATEX II cat. G/D and cat. D/G

More information

Standardized valve series MI-01 Connection pattern according to ISO 5599/1, size 1, 5/2- and 5/3-way NG and 1700 Nl/min (1.636 and 1.

Standardized valve series MI-01 Connection pattern according to ISO 5599/1, size 1, 5/2- and 5/3-way NG and 1700 Nl/min (1.636 and 1. Standardized valve series MI-01 Connection pattern according to ISO 5599/1, size 1, 5/2- and 5/3-way NG 9 1610 and 1700 Nl/min (1.636 and 1.728 Cv) Order code Series and function 1) Plug socket see page

More information

B64G - Olympian Plus plug-in system Filter/regulator

B64G - Olympian Plus plug-in system Filter/regulator BG - Olympian Plus plug-in system > > Port size: /... / (ISO G/PTF) > > High efficiency water removal > > Diaphragm and balanced valve design ensure good regulation characteristics > > on-rising adjusting

More information

Pneumatic Control/Feedback

Pneumatic Control/Feedback 897 /Feedback Type 897 can be combined with... Compact design Integrated pilot valve with manual override Internal control air routing Bright LED position indicator Automatic end position adjustment Type

More information

LB74G - EXCELON Modular System General purpose filter/regulator

LB74G - EXCELON Modular System General purpose filter/regulator LBG - EXCELON Modular System > Port size: /... / (ISO G/PFT) > Push to lock adjusting knob with optional tamper resistant accessory > Excelon design allows in-line installation or modular installation

More information

60 series, 2/2 or 3/2 Ball valve

60 series, 2/2 or 3/2 Ball valve >> Port size: Rp/..., /... >> Ideally suited for most general purpose applications >> Easy installation, simple operation and maintenance free >> -way ball valves with actuator interface conforming to

More information

V03, V04 and V05 Series

V03, V04 and V05 Series V03, V04 and V05 Series / and 3/ Poppet Valves Electrically Actuated G 1 8, G 1 4, CNOMO and Interface Extensive range of power and orifice size options Removable coil Manifold rail for 1 to 0 valves Operating

More information

Series 3730 Type Electropneumatic Positioner

Series 3730 Type Electropneumatic Positioner Series 3730 Type 3730-0 Electropneumatic Positioner Application Single-acting or double-acting positioner for attachment to pneumatic control valves Set point Travel 4 to 20 ma 5.3 to 200 mm The positioner

More information

ISO*STAR - ATEX version (SXE, SXP) 5/2 & 5/3 Solenoid and pilot actuated glandless spool valves

ISO*STAR - ATEX version (SXE, SXP) 5/2 & 5/3 Solenoid and pilot actuated glandless spool valves *STR - TX version (SX, SXP) / & / > > Sub-base mounted, 99- s, or > > Specially coated glandless spool and sleeve for long trouble-free life > > Integral flow regulators available on and s for cylinder

More information

T EN TROVIS Electropneumatic Positioner

T EN TROVIS Electropneumatic Positioner T 8484-1 EN TROVIS 3730-1 Electropneumatic Positioner Application Single-acting positioner for attachment to pneumatic globe and rotary valves. Self-calibrating, automatic adaptation to valve and actuator.

More information

Data Sheet T 8493 EN. Series 3793 TROVIS 3793 Electropneumatic Positioner with HART communication

Data Sheet T 8493 EN. Series 3793 TROVIS 3793 Electropneumatic Positioner with HART communication Data Sheet T 8493 EN Series 3793 TROVIS 3793 Electropneumatic Positioner with HART communication Application Single-acting or double-acting positioner for attachment to pneumatic control valves. Self-calibrating,

More information

Series 3730 Type Electropneumatic Positioner

Series 3730 Type Electropneumatic Positioner Series 3730 Type 3730- Electropneumatic Positioner Application Single-acting or double-acting positioner for attachment to pneumatic control valves. Self-calibrating, automatic adaptation to valve and

More information

Series 3793 TROVIS SAFE 3793 Electropneumatic Positioner with HART communication

Series 3793 TROVIS SAFE 3793 Electropneumatic Positioner with HART communication Series 3793 TROVIS SAFE 3793 Electropneumatic Positioner with HART communication Application Single-acting or double-acting positioner for attachment to pneumatic on/off valves in safety-instrumented systems.

More information

Inductive dual sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933

Inductive dual sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933 ATEX category II 2 G, Ex zone 1 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Rectangular, housing DSU35 Plastic, PP-GF30-VO Two outputs for monitoring the position of rotary actuators Mounting

More information

15 and 16 Series BSP and hose fittings

15 and 16 Series BSP and hose fittings SP and hose fittings > > Port size: M5, 1/8... 1 > > xtensive range of shapes and sizes including manifolds > > High temperature and pressure copper sealing washers supplied with ISO threads Technical

More information

Inductive sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933

Inductive sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933 ATEX category II 2 G, Ex zone 1 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1

More information

Inductive sensor Dual sensors with extended temperature range NI4-DSU35TC-2Y1X2/S97

Inductive sensor Dual sensors with extended temperature range NI4-DSU35TC-2Y1X2/S97 ATEX category II 2 G, Ex zone 1 ATEX category II 1 D, Ex-zone 20 for temperatures up to -25 C SIL2 acc. to IEC 61508 Rectangular, housing DSU35 Plastic, PP-GF30-VO Two outputs for monitoring the position

More information

Inductive sensor For rotary actuators NI4-DSU35TC-2Y1X2

Inductive sensor For rotary actuators NI4-DSU35TC-2Y1X2 ATEX category II 2 G, Ex zone 1 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1

More information

Control Head for the integrated mounting on process valves

Control Head for the integrated mounting on process valves Control Head for the integrated mounting on process valves Type can be combined with Compact stainless steel design Integrated analogue valve position registration (Teach function) Coloured illuminated

More information

Pneumatic Control Unit for the integrated mounting on process valves

Pneumatic Control Unit for the integrated mounting on process valves Pneumatic Control Unit for the integrated mounting on process valves Type 890 can be combined with Compact design Pilot valve with high air flow rate Internal control air channel Optical position indicator

More information

RM/92000/M, Short stroke cylinder Magnetic piston, double acting

RM/92000/M, Short stroke cylinder Magnetic piston, double acting > Ø... 00 mm > One third the basic length of a corresponding ISO/VDM model > Fully non-corrodible specification > Standard magnetic piston for full control system versatility > Low friction, long life

More information

Inductive sensor NI3-EG08K-Y1-H1341

Inductive sensor NI3-EG08K-Y1-H1341 ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Threaded barrel, M8 x 1 Stainless steel, 1.4427 SO DC 2-wire, nom. 8.2 VDC Output acc. to DIN EN 60947-5-6 (NA- MUR)

More information

Technical Data. General specifications. Rated operating distance s n 3 mm

Technical Data. General specifications. Rated operating distance s n 3 mm 0102 Model Number Features Direct mounting on standard actuators Compact and stable housing with terminal compartment connection ATEX & IECEX certifications Usable up to SIL 2 acc. to IEC 61508 Weatherproof

More information

Digital electropneumatic Positioner for the integrated mounting on process control valves

Digital electropneumatic Positioner for the integrated mounting on process control valves Digital electropneumatic Positioner for the integrated mounting on process s Type 8694 can be combined with Automatic teach function Contact-free position sensor Compact stainless steel design AS-Interface

More information

Inductive sensor For rotary actuators NI4-DSU35-2Y1X2-H1140

Inductive sensor For rotary actuators NI4-DSU35-2Y1X2-H1140 ATEX category II 2 G, Ex zone 1 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1

More information

26230, Inline 3/2, 5/2 and 5/3 way soft seal spool valves electromagnetic actuated, indirectly controlled G 1/4, G 1/2

26230, Inline 3/2, 5/2 and 5/3 way soft seal spool valves electromagnetic actuated, indirectly controlled G 1/4, G 1/2 /, / and / way soft seal spool valves electromagnetic actuated, indirectly controlled /, / traight-through flow, high v-factor tandard manual override ompact design asily interchangeable solenoid system

More information

PROFIBUS-PA Positioner Type 3785

PROFIBUS-PA Positioner Type 3785 PROFIBUS-PA Positioner Type 3785 Application Single-acting or double-acting PROFIBUS-PA positioner for attachment to pneumatic control valves. Rated travel from 7.5 to 120 mm Opening angle up to 120 Smart,

More information

Series 3730 Electropneumatic Positioner Type

Series 3730 Electropneumatic Positioner Type Series 3730 Electropneumatic Positioner Type 3730-0 Application Single-acting or double-acting positioner for attachment to pneumatic control valves Reference variable Travels 4 to 20 ma 5.3 to 200 mm

More information

Inductive sensor BI1.5-EG08-Y1-H1341

Inductive sensor BI1.5-EG08-Y1-H1341 ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1

More information

LMP 308. Separable Stainless Steel Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO / 0.

LMP 308. Separable Stainless Steel Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO / 0. LMP 08 Separable Stainless Steel Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.25 % FSO / 0. % FSO Nominal pressure from 0... mh 2 O up to 0... 250 mh 2 O Output signals 2-wire:

More information

Digital electropneumatic positioner

Digital electropneumatic positioner Digital electropneumatic positioner Type 879 can be combined with Compact metal housing Graphic display with backlight Easy start-up Comprehensive range of additional software functions Profibus DPV1 (optional)

More information

Inductive sensor BI1.5-EG08-Y1-H1341

Inductive sensor BI1.5-EG08-Y1-H1341 ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1

More information

SideControl Positioner

SideControl Positioner SideControl Positioner Electropneumatic positioner for pneumatically actuated process valves II (1) 2 G EEx ia IIC T6 approval can be combined with... Type 2712 Globe valve Globe valve acc. to NAMUR/IEC

More information

Digital electropneumatic positioner

Digital electropneumatic positioner Digital electropneumatic positioner Type 879 can be combined with Compact metal housing Graphic display with backlight Easy start-up Comprehensive range of additional software functions Profibus DPV1 (optional)

More information

RM/28000/M, ISO cylinder Magnetic piston, single acting

RM/28000/M, ISO cylinder Magnetic piston, single acting > > Ø 0... 5 mm > > Standard magnetic piston for full control system versatility > > Nose mounting nut and piston rod locknut as standard > > Conforming to ISO > > Optional port arrangement for compact

More information

PNEUFIT 10 series Push-in fittings

PNEUFIT 10 series Push-in fittings PNUFIT 0 series > > Port size: Ø 4... 4 mm O/D tube, SP threads > > Very compact units > > asy tube insertion for rapid assembly of pneumatic circuits > > Straight adaptors feature internal hexagon for

More information

Digital electropneumatic Positioner SideControl

Digital electropneumatic Positioner SideControl Digital electropneumatic Positioner SideControl Type 8791 BASIC can be combined with Compact and robust design Easy to start using tune function Dynamic positioning system with no air consumption in controlled

More information

Digital electropneumatic positioner SideControl

Digital electropneumatic positioner SideControl Digital electropneumatic positioner Type 879 can be combined with Compact and robust design Easy to start using tune function Integrated diagnostic functions for valve monitoring (optional) Dynamic positioning

More information

M/60100/M, Slide units Magnet piston, double acting

M/60100/M, Slide units Magnet piston, double acting M/000/M, Slide units > > Ø 0... 0 mm > > High quality sliding bearings ensure long durable life and high guidance performance > > Easy to install-reduces costly design time > > Double piston rod provides

More information

R./57100/M, R./57300/M, Roundline cylinder Magnetic piston, single acting

R./57100/M, R./57300/M, Roundline cylinder Magnetic piston, single acting R./700/M, R./700/M, Roundline cylinder > >... 0 mm > > Saves 0% space over the basic length of a corresponding ISO/ VDM cylinder > > Standard magnetic piston for full control system versatility > > Low

More information

Digital electropneumatic Positioner for the integrated mounting on process control valves

Digital electropneumatic Positioner for the integrated mounting on process control valves Digital electropneumatic Positioner for the integrated mounting on process control valves Type 8696 can be combined with Digital smart positioner Automatic teach function Contact-free position sensor Compact

More information

Series 3731 Type Electropneumatic Ex d Positioner with HART communication

Series 3731 Type Electropneumatic Ex d Positioner with HART communication Series 3731 Type 3731-3 Electropneumatic Ex d Positioner with HART communication Application Single-acting or double-acting Ex d positioner for attachment to pneumatic control valves. Self-calibrating,

More information

Sensor boxes SRBC. Festo core product range Covers 80% of your automation tasks

Sensor boxes SRBC. Festo core product range Covers 80% of your automation tasks Sensor boxes SRBC q/w Worldwide: Superb: Easy: Festo core product range Covers 80% of your automation tasks Always in stock Festo quality at an attractive price Reduces procurement and storing complexity

More information

Digital electropneumatic Positioner for the integrated mounting on process control valves

Digital electropneumatic Positioner for the integrated mounting on process control valves Digital electropneumatic Positioner for the integd mounting on process control valves Type 8692 can be combined with Compact stainless steel design Graphic display with backlight Easy start-up by automatic

More information

Electropneumatic miniature control valves Mounting Connectors Minisolenoid valves Indicators LED seals LED Valve modules Poppet 3/2 single pilot 4/2 s

Electropneumatic miniature control valves Mounting Connectors Minisolenoid valves Indicators LED seals LED Valve modules Poppet 3/2 single pilot 4/2 s ElectroPneumatic Miniature Control Valves Order/Technical Support Tel: (800) 6773 / FAX: (800) 677386 / www.crouzetusa.com /47 Electropneumatic miniature control valves Mounting Connectors Minisolenoid

More information

Series 3730 Type Electropneumatic Positioner

Series 3730 Type Electropneumatic Positioner Series 3730 Type 3730-2 Electropneumatic Positioner Application Single-acting or double-acting positioner for attachment to pneumatic control valves. Self-calibrating, automatic adaptation to valve and

More information

Series 3731 TROVIS SAFE Electropneumatic Ex d Positioner

Series 3731 TROVIS SAFE Electropneumatic Ex d Positioner Series 3731 TROVIS SAFE 3731-3 Electropneumatic Ex d Positioner with HART communication Application Single-acting or double-acting Ex d positioner for attachment to pneumatic on/off valves in safety-instrumented

More information

Magnetic Field Sensor Magnetic-inductive Proximity Sensor BIM-M12E-Y1X-H1141

Magnetic Field Sensor Magnetic-inductive Proximity Sensor BIM-M12E-Y1X-H1141 ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1

More information

Series 3731 Type Electropneumatic Ex d Positioner with FOUNDATION TM fieldbus communication

Series 3731 Type Electropneumatic Ex d Positioner with FOUNDATION TM fieldbus communication Series 3731 Type 3731-5 Electropneumatic Ex d Positioner with FOUNDATION TM fieldbus communication Application Positioners for attachment to pneumatic control valves Rated travels from 3.6 to 200 mm Opening

More information

Sensor boxes SRBE Key features and product range overview

Sensor boxes SRBE Key features and product range overview Sensor boxes SRBE Sensor boxes SRBE Key features and product range overview Function Sensor boxes SRBE are used for electrical feedback and control of the position of process valves actuated using pneumatic

More information

Control Head for the integrated mounting on process valves

Control Head for the integrated mounting on process valves Control Head for the integrated mounting on process valves Type 8695 can be combined with Compact stainless steel design Integrated analog valve position registration (Teach function) Coloured illuminated

More information

Application The DA03 serves as indicator of differential. Follow mounting instructions in accordance to application.

Application The DA03 serves as indicator of differential. Follow mounting instructions in accordance to application. DA03 Differential Pressure Gauge / Differential Pressure Gauge and Switch Models for Assignment in Explosion-hazardous Areas per Directive 94/9/EC (ATEX) Application The DA03 serves as indicator of differential

More information

Magnetic field sensor Magnetic-inductive Proximity Sensor BIM-M12E-Y1X

Magnetic field sensor Magnetic-inductive Proximity Sensor BIM-M12E-Y1X ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Threaded barrel, M12 x 1 Chrome-plated brass Rated operating distance 90 mm with DMR31-15-5 magnet DC 2-wire, nom.

More information

Digital Positioner 8049

Digital Positioner 8049 Compact digital positioner for pneumatic control valves. Positioner can be integrated into valve actuator (no external moving parts for stroke feedback) Wide range of strokes - 8 mm No steady-state air

More information

4 Remote I/O. Digital Output Module 8-Channel Version Type 9475/ from Rev. F

4 Remote I/O. Digital Output Module 8-Channel Version Type 9475/ from Rev. F 4 Remote I/O Digital Output Module 8-Channel Version 8 channels for Ex i solenoid valves, piezo and booster-valves Intrinsically safe Ex ia IIC outputs Additional input for Plant-STOP available (acc. to

More information

Digital electropneumatic Positioner for the integrated mounting on process control valves

Digital electropneumatic Positioner for the integrated mounting on process control valves Digital electropneumatic Positioner for the integrated mounting on process s Type 8694 can be combined with Digital smart positioner Automatic teach function Contact-free position sensor Compact stainless

More information

Digital electropneumatic positioner

Digital electropneumatic positioner Digital electropneumatic positioner Type 879 can be combined with Compact and robust design Easy to start using tune function Dynamic positioning system with no air consumption in controlled state Profibus

More information