Rhino SD2/XD2 DeviceNet I/O Modules
|
|
- Hubert Gibson
- 5 years ago
- Views:
Transcription
1 Instruction Sheet 6060 Rhino SD/XD DeviceNet I/O Modules Description See Figure. The DeviceNet I/O module connects to the electrical components on a Rhino SD/XD bulk unloader through -mm micro connector interface cables (). The DeviceNet station () has eight discrete inputs and outputs. The inputs are bus-powered and the outputs are auxiliary-powered. Refer to the Inputs and Outputs section for a description of each input and output. Each I/O channel Status LED (7) indicates the following: Off = Off Green = On Red = Short Circuit The DeviceNet station Module Status LED (5) indicates the following: Green = Working Properly Red = Short Circuit The DeviceNet station has bus line () and auxiliary power () connectors for connecting the Nordson controller DeviceNet cables. The node address can be set by opening the cover (6) to adjust the rotary switches. Refer to the system documentation for the proper node settings. Three DeviceNet modules are available: Type-D: For bulk unloaders that use ISO-style pneumatic control valve bases; Interface cables have straight connectors; Includes interface cables for low and empty drum level sensors Type-G: For bulk unloaders that use ISO-style pneumatic control valve bases; Interface cables have straight connectors; Includes interface cable for empty drum level sensor Type-F: For bulk unloaders that use automotive-style pneumatic control valve bases; Air solenoid valve interface cables have 90-degree connectors; Remaining cables have straight-end connectors; Includes interface cables for low and empty drum level sensors Figure Typical Rhino SD/XD DeviceNet Module 0 Nordson Corporation Part 6060
2 Rhino SD/XD DeviceNet I/O Modules Inputs and Outputs Refer to Table for a description of each input and output. Refer to the applicable module document for more information. Input Material Purge Push Button Container Level Empty Proximity Sensor Container Level Low Proximity Sensor Pump Stroke Proximity Switch* Air Pressure Switch* Material Filter Switch* Output Air Motor Control Valve Light Tower* Depressurization Air Solenoid Valve* *: Optional equipment Table DeviceNet Inputs/Outputs Description When pressed, enables inactive air motor on a crossover unloader system to be cycled for a container change or material purge Sends a signal to system controller to disable air motor when follower plate reaches bottom of material container Sends a signal to system controller when follower plate reaches a predetermined low level in material container Monitors pump strokes, cycles, and runaway conditions Indicates supply air is flowing to air motor and pump is active Indicates filter back pressure is too high and filter element needs replaced Description Controls supply air to air motor Activates when a fault occurs Activates depressurization valve on the bulk unloader; vents pump output pressure and system header pressure through follower plate and back to material container Label Locations See Figures,, and for the DeviceNet label location. Part Nordson Corporation
3 Rhino SD/XD DeviceNet I/O Modules Type-D DeviceNet Module Cable Labels LOW (CABLE #) EMPTY (CABLE #) PUSH BUTON PUSH BUTTON EMPTY (CABLE #) EMPTY (CABLE #) LOW (CABLE #) EMPTY LOW (CABLE #) LOW Figure Type-D DeviceNet Module Cable Labels 0 Nordson Corporation Part 6060
4 Rhino SD/XD DeviceNet I/O Modules Type-F DeviceNet Module Cable Labels LOW (CABLE #) EMPTY (CABLE #) PUSH BUTON PUSH BUTTON DRUM LEVEL EMPTY (CABLE #) EMPTY (CABLE #) LOW (CABLE #) EMPTY LOW (CABLE #) LOW Figure Type-F DeviceNet Module Cable Labels Part Nordson Corporation
5 Rhino SD/XD DeviceNet I/O Modules 5 Type-G DeviceNet Module Cable Labels EMPTY PUSH BUTON PUSH BUTTON EMPTY Figure Type-G DeviceNet Module Cable Labels 0 Nordson Corporation Part 6060
6 6 Rhino SD/XD DeviceNet I/O Modules DeviceNet Station See Figure 5. TY-D AND TY-F DeviceNet STATIONS TY-G DeviceNet STATION PUSH BUTTON PUSH BUTTON EMPTY/LOW LIGHT TOWER (IF REQUIRED) CONTAINER LEVEL EMPTY LIGHT TOWER (IF REQUIRED) DEPRESSURIZATION AIR SOLENOID VALVE DEPRESSURIZATION AIR SOLENOID VALVE AIR PRESSURE SWITCH () AIR PRESSURE SWITCH () Figure 5 Parts DeviceNet Station Labels To order parts, contact Nordson customer support at (00) 99 or contact a local Nordson representative. Part Nordson Corporation
7 Rhino SD/XD DeviceNet I/O Modules 7 Type-D DeviceNet Module See Figure 6 and refer to the following parts list Figure 6 Type-D DeviceNet Module Parts Item Part Description Quantity Note 076 MODULE, DeviceNet, empty/low, ISO valves 6995 MODULE, I/O, x, input DC 7 output DC PLATE, DeviceNet I/O module SCREW, drive, x 0. WASHER, flat, 0. x 0.75 x SCREW, socket, - x KIT, label, module, DeviceNet A 7 05 CABLE, -pin, MICRO DC, AWG, m 060 CABLE ASSEMBLY, -conductor, m, AWG 9 KIT, label, cable, DeviceNet A STRAP, cable, 0.75 diameter 9 STRAP, cable, CABLE, Y, -pin, MICRO DC, AWG, 0. m NOTE A: Refer to the Label Locations section on page for location of labels. 0 Nordson Corporation Part 6060
8 Rhino SD/XD DeviceNet I/O Modules Type-F DeviceNet Module See Figure 7 and the following parts list Figure 7 Type-F DeviceNet Module Parts Item Part Description Quanti Note ty MODULE, DeviceNet, empty/low, automotive valves 6995 MODULE, I/O, x, input DC 7 output DC PLATE, DeviceNet I/O module SCREW, drive, x 0. WASHER, flat, 0. x 0.75 x SCREW, socket, - x KIT, label, module, DeviceNet A CABLE ASSEMBLY, -conductor, m, AWG KIT, label, cable, DeviceNet A STRAP, cable, 0.75 diameter 0 05 CABLE, -pin, micro DC, AWG, m 056 CABLE, Y, -pin, micro DC, AWG, 0. m 055 CABLE, 90 degree, -pin, micro DC, AWG, m 9 STRAP, cable, 0.06 NOTE A: Refer to the Label Locations section for location of labels. Part Nordson Corporation
9 Rhino SD/XD DeviceNet I/O Modules 9 Type-G DeviceNet Module See Figure and refer to the following parts list Figure Type-G DeviceNet Module Parts Item Part Description Quanti Note ty MODULE, DeviceNet, empty, ISO valves 6995 MODULE, I/O, x, input DC 7 output DC PLATE, DeviceNet I/O module SCREW, drive, x WASHER, flat, 0. x 0.75 x SCREW, socket, - x KIT, label, module, DeviceNet A 7 05 CABLE, -pin, micro DC, AWG, m 060 CABLE, assembly, -conductor, m, AWG 9 KIT, label, cable, DeviceNet A STRAP, cable, 0.75 diameter 9 STRAP, cable, 0.06 NOTE A: Refer to the Label Locations section for location of labels. 0 Nordson Corporation Part 6060
10 0 Rhino SD/XD DeviceNet I/O Modules This page intentionally left blank. Part Nordson Corporation
11 Rhino SD/XD DeviceNet I/O Modules Schematics TY-D DeviceNet I/O STATION INPUTS OUTPUTS PUSHBUTTON V PIN INPUT I PIN V PIN INPUT I0 PIN I0 I 00 0 PIN PIN PIN PIN OUTPUT 0 OUTPUT 00 SOL. B SOL. A DRUM LEVEL EMPTY V INPUT I V INPUT I PIN PIN PIN PIN I I 0 0 PIN PIN PIN PIN OUTPUT 0 OUTPUT 0 LIGHT TOWER A- OR B-UNIT DRUM LEVEL LOW AIR PRESSURE SWITCH IFM EFECTOR TY V INPUT I5 V INPUT I PIN PIN PIN PIN I I PIN PIN PIN PIN OUTPUT 05 OUTPUT 0 SOL. A SOL. B DEPRESSURIZATION AIR SOLENOID VALVE OUTPUT OUTPUT AIR PRESSURE SWITCH ALLEN BRADLEY TY R V INPUT I7 V INPUT I6 PIN PIN PIN PIN I6 I PIN PIN PIN PIN OUTPUT 07 OUTPUT 06 MATERIAL FILTER A- OR B-UNIT Rhino SD/XD Type-D DeviceNet I/O Module Schematic 0 Nordson Corporation Part 6060
12 Rhino SD/XD DeviceNet I/O Modules TY-F DeviceNet I/O STATION INPUTS OUTPUTS PUSHBUTTON V INPUT I V INPUT I0 PIN PIN PIN PIN I0 I 00 0 PIN PIN PIN PIN OUTPUT 0 OUTPUT 00 SOL. A SOL. B DRUM LEVEL EMPTY V PIN INPUT I PIN V PIN INPUT I PIN I I 0 0 PIN PIN PIN PIN OUTPUT 0 OUTPUT 0 LIGHT TOWER A- OR B-UNIT DRUM LEVEL LOW AIR PRESSURE SWITCH IFM EFECTOR TY V INPUT I5 V INPUT I PIN PIN PIN PIN I I PIN PIN PIN PIN OUTPUT 05 OUTPUT 0 SOL. A SOL. B DEPRESSURIZATION AIR SOLENOID VALVE OUTPUT OUTPUT AIR PRESSURE SWITCH ALLEN BRADLEY TY R V INPUT I7 V INPUT I6 PIN PIN PIN PIN I6 I7 PIN 06 PIN PIN 07 PIN OUTPUT 07 OUTPUT 06 MATERIAL FILTER A- OR B-UNIT Rhino SD/XD Type-F DeviceNet I/O Module Schematic 0 Nordson Corporation Part 6060
13 Rhino SD/XD DeviceNet I/O Modules TY-G DeviceNet I/O STATION INPUTS OUTPUTS PUSHBUTTON V INPUT I V INPUT I0 PIN PIN PIN PIN I0 I 00 0 PIN PIN PIN PIN OUTPUT 0 OUTPUT 00 SOL. B SOL. A DRUM LEVEL EMPTY INPUT I INPUT I PIN V V PIN PIN PIN I 0 PIN PIN PIN I 0 PIN OUTPUT 0 OUTPUT 0 LIGHT TOWER A- OR B-UNIT AIR PRESSURE SWITCH IFM EFECTOR TY V PIN INPUT I5 PIN V PIN INPUT I PIN I I PIN PIN PIN PIN OUTPUT 05 OUTPUT 0 SOL. A SOL. B DEPRESSURIZATION AIR SOLENOID VALVE OUTPUT OUTPUT AIR PRESSURE SWITCH ALLEN BRADLEY TY R V INPUT I7 V INPUT I6 PIN PIN PIN PIN I6 I PIN PIN PIN PIN OUTPUT 07 OUTPUT 06 MATERIAL FILTER A- OR B-UNIT Rhino SD/XD Type-G DeviceNet I/O Module Schematic 0 Nordson Corporation Part 6060
14 Rhino SD/XD DeviceNet I/O Modules Issued 7/ Original copyright date 0. Rhino, Nordson, and the Nordson logo are registered trademarks of Nordson Corporation. All other trademarks are the property of their respective owner. 0 Nordson Corporation Part 6060
Rhino SD3/XD3 Ethernet I/O Module
Instruction Sheet P/N 6777 0 Rhino SD/XD Ethernet I/O Modules Description See Figure. The Rhino SD/XD Ethernet I/O module connects to the electrical components on a Rhino SD/XD bulk unloader through -mm
More information01348(N or G) MH** -- Material Handling (N or G) MH** -- Material Handling
MATERIAL HANDLING MANIFOLDS WITH DeviceNet INTERFACE 01348(N or G) MH** -- Material Handling 01351(N or G) MH** -- Material Handling Note: N = NPT ports G = BSPP ports SOL 14 SOL 12 Station #3 SOL 14 SOL
More informationSure Coat Modular Gun Control System Part C: UCS ProfiBus Interface Card. Customer Product Manual Part B
Sure Coat Modular Gun Control System Part C: UCS ProfiBus Interface Card Customer Product Manual Issued 4/02 For parts and technical support, call the Industrial Coating Systems Customer Support Center
More information01325T -- Robot Welder
WELDING MANIFOLDS WITH DeviceNet INTERFACE 01325T -- Robot Welder 01326T -- Pedestal Welder Station #2 (WELD) SOL 14 Station #1 (BACKUP) SOL 14 SOL 12 Prop. Reg. Water Saver Inputs Power (Aux.) DeviceNet
More informationSure Coat Modular Gun Control System Part C: Discrete I/O Interface Card. Customer Product Manual Part B
Sure Coat Modular Gun Control System Part C: Discrete I/O Interface Card Customer Product Manual Issued 4/03 For parts and technical support, call the Industrial Coating Systems Customer Support Center
More informationSERVICE PARTS MANUAL
SERVICE PARTS MANUAL SERIES SNOW PLOWS WITH EIS PLOW LIGHT HARNESS CONNECTIONS FOR GRAVITY HYDRAULICS WITH SERIAL NUMBERS BEFORE G10000 WITH SERIAL NUMBERS AFTER G00000 FOR DOWN PRESSURE HYDRAULICS WITH
More informationLevel-Process Training System
Level-Process Training System LabVolt Series Datasheet Festo Didactic en 220 V - 50 Hz 07/2018 Table of Contents General Description 2 PLC Compatibility 2 Features & Benefits 2 List of Equipment 3 List
More informationElectro-Pneumatic Training System
8075-20 Electro-Pneumatic Training System LabVolt Series Datasheet Festo Didactic en 01/2018 Table of Contents General Description 2 PLC Compatibility 2 Features & Benefits 2 List of Equipment 2 List of
More information2002 Series DeviceNet Technical Manual
2002 Series DeviceNet Technical Manual Table of Contents 2002 Series DeviceNet Technical Manual 2002 Introduction...4 Product Overview...4 About DeviceNet...5 Overview...5 2002 DeviceNet Features...5 Cabling
More informationAutoScan to MultiScan Replacement Kit
Instruction Sheet P/N AutoScan to MultiScan Replacement Kit WARNING: Allow only qualified personnel to perform the following tasks. Observe and follow the safety instructions in this document and all other
More informationMPCR Series DeviceNet Technical Manual TDMPCRDNTM2-0EN 01/08 Subject to change without notice
MPCR Series DeviceNet Technical Manual Table of Contents MPCR Series Introduction... 3 Product Overview... 3 About DeviceNet... 4 Overview... 4 MPCR DeviceNet Features... 4 Cabling and Drop Line Lengths
More informationControl Head for the integrated mounting on process valves
Control Head for the integrated mounting on process valves Type 8691 can be combined with Compact stainless steel design Integrated analogue valve position registration (Teach function) Coloured illuminated
More informationDIN Molded Cable Assemblies
DIN 43650 Telephone (973) 586-500 FAX (973) 596-590 DIN 43650 8mm For Solenoid Valve Applications Black PVC Cable & Connector DUAL JUMPED GROUND PINS Molded cable assemblies can be mounted with cable exiting
More informationMPCR Series DeviceNet Technical Manual
MPCR Series DeviceNet Technical Manual Table of Contents MPCR Series Introduction...3 Product Overview...3 About DeviceNet...4 Overview...4 MPCR DeviceNet Features...4 Cabling and Drop Line Lengths (as
More informationKeystone OM1 - EPI-2 modulating input/output module Installation and Maintenance Instructions
Before installation these instructions must be fully read and understood Index 1 Optional module 1: Modulating I/O module... 1 2 Installation... 2 3 OM1 card setting and configuration... 6 4 Monitor relay
More informationY-0044 MECHATRONICS TRAINING SET
INDUSTRIAL AUTOMATION TECHNOLOGY Y-0044 MECHATRONICS TRAINING SET With the mechatronics training set typical factory automation is modeled. Due to the scenario the factory automation; product that is rough
More informationConveyor Station Exercise 1: Learning about components and their function
Conveyor Station Exercise 1: Learning about components and their function Learning objective Upon completing this exercise, you should be familiar with the most important components in the conveyor station
More informationControl head for hygienic process valves
for hygienic process valves Type can be combined with... Universal attachment for hygienic process valves Contactless position measurement system with 3 switching points (Teach-In function) Coloured status
More informationFlexible Manufacturing System 1 AE-PLC-FMS1
Flexible Manufacturing System 1 AE-PLC-FMS1 Engineering and Technical Teaching Equipment Available with PLC, as: - PANASONIC - SIEMENS - MITSUBISHI - ALLEN BRADLEY - OMRON Etc... Computer Control System
More information2005 / 2012 / 2035 Series
Generail Information on Fieldbus Systems FEATURES Solenoid air operated valve manifolds for date exchange via fieldbus. Internal wiring by Z-Board plug-in system. Plug-together flexibility due to different
More informationIndustrial Communication System
Industrial Communication System Isysnet / Moduflex Isysnet system for centralised and decentralised applications Isysnet System for Centralised applications Isysnet System has 4 major components : Communication
More informationSERVICE PARTS MANUAL
SERVICE PARTS MANUAL 8 SERIES SNOW PLOW FOR SERIAL NUMBERS AFTER 8D100000 00 Sno-Way International 9100G TABLE OF CONTENTS PAGE DEFLECTORS... POWER PACK... HYDRAULIC POWER UNIT... LIFT CYLINDER... ANGLE
More informationOperation and Service Guide: Showers P.O. Box 309 Menomonee Falls, WI BRADLEY Fax: bradleycorp.com
Micro-Touch How Micro-Touch TM III Works See Below 1. Pushbutton sends electrical impluse (millivolts) to circuit board. 2. Circuit board controls metering style and timing sent to solenoid. 3. Solenoid
More informationHelm-Pak Survey. SPM: Tonnage: English Metric Type: OBI/Gap Straight Side Single Action Double Action
Company Phone: Address: Fax: City: Contact: State: Zip: Email: Rep.: Company: Press Data: Manufacturer: Model: Serial Number: Year of Manufacture: SPM: Tonnage: English Metric Type: OBI/Gap Straight Side
More informationDigital electropneumatic Positioner for the integrated mounting on process control valves
Digital electropneumatic Positioner for the integrated mounting on process control valves Type 8692 can be combined with Compact stainless steel design Graphic display with backlight Easy start-up Comprehensive
More informationDigital electropneumatic Positioner for the integrated mounting on process control valves
Digital electropneumatic Positioner for the integd mounting on process control valves Type 8692 can be combined with Compact stainless steel design Graphic display with backlight Easy start-up by automatic
More informationEncore XT Manual Gun Upgrade Kit
Instruction Sheet P/N 1600823-01 Encore XT Manual Gun Upgrade Kit 1600834 Introduction Follow these instructions to upgrade your Encore manual spray gun to the improved design of the Encore XT spray gun.
More informationELECTRICAL CONNECTORS ALL PRODUCTS
ELECTRICAL CONNECTORS ALL PRODUCTS RENEWAL PARTS Supersedes: NOTHING Form 50.20-RP1 (103) LD08685 TABLE OF CONTENTS PAGE Single Line Micropanel...3 Optiview Panels...4 VSD's and Solid State Starters...5
More informationCI-100 and CI-170 Parts Catalog. Document
CI-100 and CI-170 Parts Catalog Industrial Dynamics Company, Ltd. Copyright 2011. All rights reserved. No part of this publication may be reproduced or used in any form or by any means (graphic, electronic,
More informationFMS-200 Flexible integrated assembly systems
FMS-200 Flexible integrated assembly systems Integrated training in industrial automation In the following TECHNOLOGIES... Hydraulics Electrical panel Pneumatics Vacuum Electric Motors SENSORS Identification
More informationStandard icontrol Power Supply Kit
Instruction Sheet P/N 07150A Standard icontrol Power Supply Kit This instruction sheet is a guide for upgrading to the Standard icontrol Power Supply. WARNING: Allow only qualified personnel to perform
More informationValve terminal RE-10 with Multi-pin, AS-Interface or bus connection 4 12 valve stations, 300 Nl/min (0.305 Cv)
Type of connection = AS = B1 = B6 Order code RE-10/08-M-1-060 Series Number of stations Multi-pin: 4, 6, 8, 10, 12 Bus versions: 4, 8, 12 Electrical options M-1 = Multi-pin D-Sub plug AS3 = AS-Interface
More informationCoolwave 2 Control Board Upgrade Kit
Instruction Sheet P/N 1612622-01 Coolwave 2 Control Board Upgrade Kit NOTE: Retain the box used for shipping the control board and contactor to comply with the conditions of warranty. WARNING: Allow only
More informationProdigy Color-on-Demand System Generation III
Prodigy Color-on-Demand System Generation III Customer Product Manual Issued 10/10 For parts and technical support, call the Finishing Customer Support Center at (800) 433-9319. This document is available
More informationThe OHMIC RESISTORS Pty. Ltd.
The OHMIC RESISTORS Pty. Ltd. The operating mechanism is arranged between and above two steel end plates held apart by three mild steel spacing rods. The handle mechanism is mounted above the top plate.
More informationModel QRS CPVS
SPARE PARTS LIST EN CP COMPRESSOR Model QRS 0-5 - 0 CPVS 0-5 - 0 6 05 50 65 KEY - Door Panel: 655900 Lock - Door Panel: 005076 QRS 0 CONTENTS Title Page MAINTENANCE HOW TO READ THIS SPARE PART LIST? KIT
More informationInk-Dot Series II Driver
Instruction Sheet P/N 766B Ink-Dot Series II Driver Introduction See Figure. Ink-Dot Series II controllers can have from one to three driver modules. Any existing controller can easily be retrofit with
More informationMAC VALVES, INC. A ENGINEERING RELEASE TRJ B EDS UPDATE / NAME CHANGE BI 284 TJR/KD. User s Manual for MAC Valves DeviceNet
MAC VALVES, INC. DOCUMENT NUMBER TITLE: User s Manual for MAC Valves DeviceNet PAGE 1 OF 24 UI-20 SM16 Manifold REVISION LEVEL DATE RELEASED CHANGE ECN NUMBER P.E. APPROVAL P.D. APPROVAL A 7-21-99 ENGINEERING
More information1) Examine exterior of package for signs of damage. Report any damage to shipping carrier.
Getting Started This is a brief document designed to quickly get you started setting up your 2002 Series valve manifold with integrated Numatics G2-1\2 Profibus-DP communication protocol. Please note that
More informationReplacing a Precision Controller Circuit Board
Instruction heet Replacing a Precision Controller Circuit Board WARNING: Allow only qualified personnel to perform the following tasks. Observe and follow the safety instructions in this document and all
More informationOperating instructions valve control box AS-i
THIS LEAFLET SHOULD BE KEPT IN A SAFE PLACE FOR REFERENCE Operating instructions valve control box AS-i 1 System description The Norgren Herion valve control box is used for controlling pneumatic swivel
More informationINSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS Accessory Application Publications No. MP3 ATTACHMENT KIT 2006 RIDGELINE AII 28615 Issue Date FEB 2005 PARTS LIST Attachment Kit: P/N 08B06-SJC-100 MP3 Player Kit (sold separately):
More informationAtlas Copco. Dryers BD 480. Parts list. From following serial No. onwards: APF
Atlas Copco Dryers BD 480 Parts list From following serial No. onwards: APF 56 875 Copyright 0, Atlas Copco Airpower n.v., Antwerp, Belgium. Any unauthorized use or copying of the contents or any part
More informationTool Changers Sigma 3.1. Sigma 3.1 Robot Adaptor S3.1R-P-2PNP-E-100-A000
Tool Changers Sigma 3.1 Sigma 3.1 Robot Adaptor S3.1R-P-2PNP-E-100-A000 XChange Sigma 3 Robot Adaptor Unit, integrated pneumatic actuation cylinder, 1/4 BSPP actuation ports, 24 VDC PNP Proximity type
More informationAn ISO 9001 Company. BOP 1KW-MG FIRMWARE RETROFIT KIT
INSTRUCTION MANUAL 1. DESCRIPTION KEPCO An ISO 9001 Company. BOP 1KW-MG FIRMWARE RETROFIT KIT BOP 1KW-MG RETROFIT KIT 219-0597 Kepco KIT 219-0597 contains the PROMs used to upgrade the firmware for BOP
More informationSECTION SOLID-STATE REDUCED VOLTAGE STARTERS
SECTION 26 29 13.16 PART 1 - GENERAL 1.1 THE REQUIREMENT A. General: The CONTRACTOR shall provide solid-state reduced voltage motor starters, complete and operable, in accordance with the Contract Documents.
More informationAC Micro Style Cordsets and Receptacles
AC Micro Style Cordsets and Receptacles Description Rockwell Automation/Allen-Bradley offers a wide variety of connection products for interfacing field devices to I/O, junction boxes, PLCs, etc. Connection
More informationPLC Applications. LabVolt Series. Datasheet
PLC Applications LabVolt Series Datasheet Festo Didactic en 240 V - 50 Hz 07/2018 Table of Contents General Description 2 Courseware 2 PLC Compatibility 2 PLC Requirements 3 Topic Coverage 3 Features &
More information256 Kbytes (1771-DRS) 1 Mbyte (1771-DRS1) 4 Mbytes (1771-DRS4) Installation Data
Installation Data You can add static RAM memory to your control coprocessor main module to expand user memory. The RAM single inline memory module (SIMM) is available in the following sizes: 256 Kbytes
More informationHigh Precision Dispensers. Ultimus I, II, III, IV and V
High Precision Dispensers Ultimus I, II, III, IV and V Ultimus I, II and III Features and Benefits All-digital, multi-function display 16 memory settings 4-decimal time setting Multilingual display Operator
More information1) Examine exterior of package for signs of damage. Report any damage to shipping carrier.
I P MAC AD D RE S S Getting Started This is a brief document designed to quickly get you started setting up your valve manifold with an integrated Numatics G2-2 Series EtherNet/IP communication node. 1)
More informationElectropneumatics Basic Level Textbook TP 201
Electropneumatics Basic Level Textbook TP 201 Festo Didactic 091181 en Order No.: 091181 Edition: 07/2004 Author: F. Ebel, G. Prede, D. Scholz Graphics: Doris Schwarzenberger Layout: 19.07.04, Susanne
More informationABM International, Inc. Lightning Stitch Checklist 9/13/2013
ABM International, Inc. Lightning Stitch Checklist 9/13/2013 1) Piggy backed board assembly (1) Piggy back board assembly tested? Yes No 24v passed XB passed XA passed YB passed YA passed SAFE passed S/S
More informationControl Head for the integrated mounting on process valves
Control Head for the integrated mounting on process valves Type can be combined with Compact stainless steel design Integrated analogue valve position registration (Teach function) Coloured illuminated
More informationProximity sensors, block-shaped Product range overview
Proximity sensors, block-shaped Product range overview Measuring Version Type Assembly Switching element function Switch output Electricalconnection principle N/C contact Cable Plug Magneto- Operating
More informationPneumatic Control/Feedback
897 /Feedback Type 897 can be combined with... Compact design Integrated pilot valve with manual override Internal control air routing Bright LED position indicator Automatic end position adjustment Type
More informationAnswers to Chapter 2 Review Questions. 2. To convert controller signals into external signals that are used to control the machine or process
Answers to Chapter 2 Review Questions 1. To accept signals from the machine or process devices and to convert them into signals that can be used by the controller 2. To convert controller signals into
More informationProgrammable Logic Controller (PLC) Guide
Programmable Logic Controller (PLC) Guide World Leader in Technical Training INTERNATIONAL AWARD WINNER FOR EXCELLENCE IN TECHNICAL TRAINING PRODUCTS Lab-Volt is the proud recipient of more International
More informationCODE 50108, 50110, 50164, 50165
CODE 50108, 50110, 50164, 50165 ASSEMBLY PAGE NAME Machine Assembly Machine Assembly Machine Assembly (Wire feed chamber) Machine Assembly (Wire feed chamber) Feeding Unit Assembly CODE NO.: K NO.: FIGURE
More information1. Carefully unpack the um260 s shipping carton and check the contents for damage.
um260 Installation Manual um260 Installation Chapter 4 um260 MICRO MONITOR INSTALLATION This section of the um260 Micro Monitor Installation Manual describes the requirements and procedures for installing
More informationAir gap sensors SOPA
Product range overview Key features General Lightweight, compact and highly precise, this pneumatic solution offers impressive scope for integration: SOPA features a control module, compressed air regulation,
More informationDigital electropneumatic Positioner for the integrated mounting on process control valves
Digital electropneumatic Positioner for the integrated mounting on process s Type 8694 can be combined with Digital smart positioner Automatic teach function Contact-free position sensor Compact stainless
More informationTable of Contents. C. Control and Signal Modules...3 DH9-M, DH5-T InstaTool DeviceNet Modules...3
Table of Contents C. Control and Signal Modules...3 DH9-M, DH5-T InstaTool DeviceNet Modules...3 1. Product Overview... 3 1.1 InstaTool DeviceNet Module... 3 2. Installation... 5 2.1 Installing... 5 2.2
More informationSure Coat Modular Gun Control System Part C: Purge Timer Interface Card. Customer Product Manual Part B
Sure Coat Modular Gun Control System Part C: Purge Timer Interface Card Customer Product Manual Issued 4/03 For parts and technical support, call the Industrial Coating Systems Customer Support Center
More informationMAS-200 Modular assembly system
MAS-200 Modular assembly system Modular training system which emulates a real industrial assembly process In the following TECHNOLOGIES... Electrical panel Pneumatics Vacuum SENSORS Identification systems
More informationPneumatic Control/Feedback
897 /Feedback Type 897 can be combined with... Compact design Integrated pilot valve with manual override Internal control air routing Automatic end position adjustment With ATEX II cat. G/D and cat. D/G
More informationPneumatic Control/Feedback
897 /Feedback Type 897 can be combined with... Compact design Integrated pilot valve with manual override Internal control air routing Bright LED position indicator Automatic end position adjustment Type
More informationElectro-Mechanical Training System with Stepper Motor
Electro-Mechanical Training System with Stepper Motor LabVolt Series Datasheet Festo Didactic en 220 V - 50 Hz 06/2018 Table of Contents General Description 2 PLC Compatibility 2 Features & Benefits 2
More informationELECTRICAL CONTROL SYSTEMS 1
ELECTRICAL CONTROL SYSTEMS 1 LEARNING ACTIVITY PACKET CONTROL LOGIC BB703-XB01UEN LEARNING ACTIVITY PACKET 1 CONTROL LOGIC INTRODUCTION This LAP and the ones that follow cover the electrical controls that
More informationFan-Drive Controller. 1 Description. 2 Technical data ESLF101/ELLF General. 1.2 Models. 1.3 Application example. 2.
Fan-Drive Controller ESLF101/ELLF101 Fan speed is controlled to match system requirements Any target value for temperature can be set For reversible and non-reversible fan motors 1 Description 1.1 General
More informationPneumatic Control Unit for the integrated mounting on process valves
Pneumatic Control Unit for the integrated mounting on process valves Type 890 can be combined with Compact design Pilot valve with high air flow rate Internal control air channel Optical position indicator
More informationDiagnostics (Logical) Diagnostics (Physical)
Enclosure Mounted Input/Output Stations In-Cabinet I/O IP 20 Protection Ideal for Retrofits Automatic Baud Rate Sensing FDN20-4S-4XSG FDN20-4S-4XSG-E* FDN20-4S-4XSG-DIN* * Not UL Electrical Operating Current:
More informationOrdering Information Ordering Data I/O Module Part numbers 12mm (micro) connectors 8 I/O per module Singular I/O module Left hand I/
Direct to PLC modules Numatics new line of with integrated I/O modules, allows a single multi-conductor cable connection to the manifold. This cable can handle the power, the valves and the sensor inputs
More informationDigital electropneumatic positioner
Digital electropneumatic positioner Type 879 can be combined with Compact metal housing Graphic display with backlight Easy start-up Comprehensive range of additional software functions Profibus DPV1 (optional)
More informationQuick Start Manual G2-2 Series with Ethernet Interface
Getting Started This is a brief document designed to quickly get you started setting up your valve manifold with integrated G2-2 series EtherNet/IP communication protocol. 1) Initial Unpacking and Inspection
More informationElectropneumatic miniature control valves Mounting Connectors Minisolenoid valves Indicators LED seals LED Valve modules Poppet 3/2 single pilot 4/2 s
ElectroPneumatic Miniature Control Valves Order/Technical Support Tel: (800) 6773 / FAX: (800) 677386 / www.crouzetusa.com /47 Electropneumatic miniature control valves Mounting Connectors Minisolenoid
More informationLet s take a look at the central vacuum conveying control choices we have today.
Let s take a look at the central vacuum conveying control choices we have today. First, a little background: Conveying controls for central vacuum systems have several jobs to do: 1. They connect and monitor
More informationG3 Series DeviceNet TM Technical Manual
G3 Series DeviceNet TM Technical Manual Table of Contents G3 Series DeviceNet Technical Manual PAGE About DeviceNet... 3 Overview... 3 G3 DeviceNet Features... 3 Cabling and Drop Line Lengths (as defined
More informationManual. LC-16 system. LC-16 Inkjet Printer 1
Manual LC-16 system LC-16 Inkjet Printer 1 Index ENVIRONMENT. 3 OPERATOR S SAFETY 3 OPERATION SAFETY 3 PART 1 INSTALLATION AND PARAMETER SETTING 4 1) Preparing 4 2) Installation 4 3) Priming 4 4) Parameter
More informationDigital electropneumatic positioner
Digital electropneumatic positioner Type 879 can be combined with Compact and robust design Easy to start using tune function Dynamic positioning system with no air consumption in controlled state Profibus
More informationFlexible Manufacturing Systems (FMS) ( )
Flexible Manufacturing Systems (FMS) 593318 (5901-00) LabVolt Series Datasheet Festo Didactic en 120 V - 60 Hz 11/2018 Table of Contents General Description 2 Topic Coverage 2 Features & Benefits 2 List
More informationINSTRUCTION MANUAL RA 59 RACK ADAPTER. 1) This manual is valid for the following Model and associated serial numbers: MODEL SERIAL NO. REV. NO.
INSTRUCTION MANUAL RA 59 RACK ADAPTER KEPCO INC. An ISO 9001 Company. MODEL RA 59 RACK ADAPTER ORDER NO. REV. NO. IMPORTANT NOTES: 1) This manual is valid for the following Model and associated serial
More informationMecLab Mechatronics Training System
MecLab Mechatronics Training System MecLab Mechatronics Training Automation Training System Automated systems are found in almost every industry today. It is one of the most important growth technologies
More informationNote: Indented items indicate parts included in an assembly listed above
Note: Indented items indicate parts included in an assembly listed above Part Name/Description Part Number QTY ISO Fertilizer Kit AgroSpray Fertilizer Stand 4200165 1 Generic Cable Installation Kit 2000901-1
More informationStandardized valve series MI-01 Connection pattern according to ISO 5599/1, size 1, 5/2- and 5/3-way NG and 1700 Nl/min (1.636 and 1.
Standardized valve series MI-01 Connection pattern according to ISO 5599/1, size 1, 5/2- and 5/3-way NG 9 1610 and 1700 Nl/min (1.636 and 1.728 Cv) Order code Series and function 1) Plug socket see page
More informationFOOD AND BEVERAGE AUTOMATION & ELECTRICAL SOLUTIONS
FOOD AND BEVERAGE AUTOMATION & ELECTRICAL SOLUTIONS MOLEX PROVIDES SOLUTIONS FOR FOOD AND BEVERAGE AUTOMATION PLANT INFRASTRUCTURES GLOBALLY. Our team of highly-skilled experts is focused on designing
More informationTrouble Shooting Leveling Control Box Electric Jacks. Touch Pad LED Probable Cause Solution
Trouble Shooting Leveling Control Box 140-1224 Electric Jacks Copyright Power Gear Issued: January 2013 #82-L0524, Rev. OA Touch Pad LED Probable Cause Solution 1. On/Off LED will not light 2. Wait LED
More informationParts Manual. SpeedLimiter D000030R01 YOUR EFFICIENCY IS OUR CHALLENGE. ESL2 ( electronic ) SL4 ( mechanical ) Speed Limiter - SL4
Parts Manual ESL2 ( electronic ) Speed Limiter - SL4 10-32 Vdc 00 0002 02 1212 - F1185.03 SL4 ( mechanical ) SpeedLimiter D000030R01 YOUR EFFICIENCY IS OUR CHALLENGE All rights reserved. No part of this
More informationThis Datasheet for the IC697CHS790. Rack, 9 Slots, Rear Mount.
This Datasheet for the IC697CHS790 Rack, 9 Slots, Rear Mount. http://www.cimtecautomation.com/parts/p-14771-ic697chs790.aspx Provides the wiring diagrams and installation guidelines for this GE Series
More informationEtherCAT compatible Slave Unit added to the Series. EtherCAT Compatible Serial Transmission Slave Unit W4G-OPP8 Series. CKD Corporation.
New product EtherCAT Compatible Serial Transmission Slave Unit W4G-OPP8 Series EtherCAT compatible Slave Unit added to the Series Overview Valve wiring is reduced through the support of high-speed EtherCAT
More informationKeystone OM1 - EPI-2 modulating input/output module Installation and Maintenance Instructions
Before installation these instructions must be fully read and understood Index 1. Optional module 1: Modulating I/O module... 1 2. Installation... 2 3. OM1 card setting and configuration... 6 4. Monitor
More informationMultipole and Fieldbus
CATALOGUE > Release 8.8 > Series F valve islands Series F valve islands, Multipole and Fieldbus New versions Multipole integrated electrical connection (PNP) Valve functions: x/; x3/; 5/; 5/3 CC It can
More informationNote: Indented items indicate parts included in an assembly listed above
Note: Indented items indicate parts included in an assembly listed above Part Name/Description Part Number QTY ISO Fertilizer Kit AgXcel Dual Pump 4200164 1 Dust Plug 12 pin 2002899-12N 1 Installation
More informationFieldbus Direct Key features
Key features The system Extremely compact and spacesaving design Low-cost solution for the connection of a small number of valves to a fieldbus Extremely safe, protection class up to IP65 depending on
More informationPositioner CMSX-...-C-U-F1-...
Positioner CMSX-...-C-U-F-... Festo AG & Co. KG Ruiter Straße 8 Esslingen Germany +9-0 www.festo.com Product overview. Function The CMSX digital electropneumatic positioner enables simple and efficient
More informationG2-2 ControlNet 2005/2012 Series Technical Manual
G2-2 ControlNet 2005/202 Series Technical Manual LT2005/202CNTECH- 0/03 www.numatics.com Table of Contents 2005/202 Series ControlNet Technical Manual PAGE About ControlNet... 3 Overview... 3 G2-2 ControlNet
More information5/2 and 5/3 Directional-control valves, Series TC 15, G 1/4
5/2 and 5/3 Directional-control valves, Series TC 15, G 1/4 Products 5/2 Directional-control valve, single valve, electrical connection M8 (4 poles) 5/3 Directional-control valve, single valve, electrical
More informationTable of Contents. Fieldbus Electronics and I/O G2-1 Electronics G2-2 Electronics Individual Base Node...
Table of Contents Fieldbus Electronics and I/O............................... - G- Electronics..................................................................... - Features and Benefits..................................................................................
More informationDirectCommand Installation 5 Channel Spreader Control Module Technology
DirectCommand Installation Ag Leader Technology Note: Indented items indicate parts included in an assembly listed above Part Name/Description Part Number Quantity Direct Command Kit 4100582 1 Cable Installation
More informationDigital electropneumatic positioner
Digital electropneumatic positioner Type 879 can be combined with Compact metal housing Graphic display with backlight Easy start-up Comprehensive range of additional software functions Profibus DPV1 (optional)
More information