pointofsale available at your local trade outlet
|
|
- MargaretMargaret Hodges
- 5 years ago
- Views:
Transcription
1 pointofsale available at your local trade outlet
2 pointofsale products IP65 pushbuttons Ø22.5mm Contact 240V AC 10A Resistive (AC1), 6A (AC15) PB01C PB02C PB03C PB04C PB05C PB06C PB07C PB08C PB09C PB10C PB11C PB14C PB17C PB40C CT01C CT02C Black pushbutton Green pushbutton Red pushbutton 2 Position rotary knob 3 Position rotary knob Panel collar with 1 N/O + 1 N/C contact block Emergency stop button Emergency stop key release Red mushroom stop button (non-latching) 2 Position key switch 3 Position key switch Emergency stop button complete Palm/foot emergency stop-button Pushbutton double head Red/Green Contact blocks for use with pushbutton enclosures Contact 240V AC 10A Resistive (AC1), 6A (AC15) Contact block 1 N/O + 1 N/C Contact block 2 N/O 3 Pole contactors & accessories CR01C CR02C CR03C CR04C CR07C CR08C CR09C CR10C CR11C CR12C AC01C AC02C AC1 25A contactor 240V AC coil AC1 25A contactor 415V AC coil AC1 32A contactor 240V AC coil AC1 32A contactor 415V AC coil AC1 50A contactor 240V AC coil AC1 50A contactor 415V AC coil AC1 80A contactor 240V AC coil AC1 80A contactor 415V AC coil AC1 110A contactor 240V ACcoil AC1 110A contactor 415V AC coil 1N/C auxiliary contact (2 pcs) 1N/O auxiliary contact (2pcs) Other voltages available 4 Pole contactors Indicators Ø22.5mm PL04C Red Pilot light 230VAC PL05C Green Pilot light 230VAC CR06 CR32 CR33 CR34 CR35 25A AC1 4 pole contactors 240V AC 30A AC1 4 pole contactors 240V AC 45A AC1 4 pole contactors 240V AC 80A AC1 4 pole contactors 240V AC 100A AC1 4 pole contactors 240V AC Pushbutton enclosures EN01C EN02C EN03C EN04C Single button enclosure Single button enclosure with yellow cover Double button enclosure Triple button enclosure Orderline information Panel mounting parts Modular contactors Enclosure mounting parts CR40C CR41C CR42C CR43C Heating/lighting contactor 20A 2 pole 240V AC Heating/lighting contactor 25A 4 pole 240V AC Heating/lighting contactor 40A 4 pole 240V AC Heating/lighting contactor 63A 4 pole 240V AC
3 Relays RL01C 8 Pin 240V AC relay RL02C 11 Pin 240V AC relay RL03C 8 Pin 110V AC relay RL04C 11 Pin 110V AC relay RL05C 8 Pin 24V AC relay RL06C 8 Pin 24V DC relay RL07C 11 Pin 24V AC relay RL08C 11 Pin 24V DC relay RL09C 8 Pin 12V DC relay RL10C 11 Pin 12V DC relay RL11C 14 Pin 240V AC relay RL12C 14 Pin 24V DC relay RL13C 14 Pin 110V AC relay RL14C 14 Pin 24V AC relay RL15C 14 Pin 12V DC relay RL16C 8 Pin 12V AC relay RL17C 11 Pin 12V AC relay Enclosed starters Direct on-line and star delta 20mm entry, IP65 pre-wired SR01D SR02D SR03D SR04D SR10C SR11C SR12C SR13C SD10C SD11C SD12C SD13C SD20C SD21C SD22C SD23C 4kW DOL Starter 240V AC coil 4kW DOL Starter 415V AC coil 7.5kW DOL Starter 240V AC coil 7.5kW DOL Starter 415V AC coil 4.5kW 240V AC DOL with Isolator 4.5kW 415V AC DOL with Isolator 7.5kW 240V AC DOL with Isolator 7.5kW 415V AC DOL with Isolator 7.5kW 240V AC Star Delta Starter 7.5kW 415V AC Star Delta Starter 15kW 240V AC Star Delta Starter 15kW 415V AC Star Delta Starter 7.5kW 240V AC Star Delta Starter with Isolator 7.5kW 415V AC Star Delta Starter with Isolator 15kW 240V AC Star Delta Starter with Isolator 15kW 415V AC Star Delta Starter with Isolator Overloads Sockets BA01C 8 Pin base BA02C 11 Pin base BA03C 14 Pin base OL01D Overload 0.6A to 0.9A OL02D Overload 0.8A to 1.2A OL03D Overload 1.2A to 1.8A OL04D Overload 1.8A to 2.7A OL05D Overload 2.7A to 4.0A OL06D Overload 4.0A to 6.0A OL07D Overload 6.0A to 9.0A OL08D Overload 8.0A to 11.0A OL09D Overload 10.0A to 14.0A OL10D Overload 13.0A to 18.0A Other sizes available Contactor/Relay enclosures EN05C IP65 small enclosure to suit contactors & relays Timer TM34C Multi-function DIN timer IP65 3 & 4 pole changeover switches CO320 CO420 CO325 CO425 CO332 CO432 CO340 CO440 CO363 CO463 CO380 CO480 20A 3 pole changeover switch 20A 4 pole changeover switch 25A 3 pole changeover switch 25A 4 pole changeover switch 32A 3 pole changeover switch 32A 4 pole changeover switch 40A 3 pole changeover switch 40A 4 pole changeover switch 63A 3 pole changeover switch 63A 4 pole changeover switch 80A 3 pole changeover switch 80A 4 pole changeover switch
4 IP65 enclosed isolators IS01C IS02C IS03C IS04C IS05C IS06C IS07C IS08C IS09C IS10C IS11C IS12C IS620 IS820 IS625 IS825 IS632 IS832 IS640 IS840 IS663 IS863 IS680 IS880 ES06 ES08 ES21 ES23 ES40 20A 3 pole isolator 20A 4 pole isolator 25A 3 pole isolator 25A 4 pole isolator 40A 3 pole isolator 40A 4 pole isolator 63A 3 pole isolator 63A 4 pole isolator 80A 3 pole isolator 80A 4 pole isolator 32A 3 pole isolator 32A 4 pole isolator 20A 6 pole isolator 20A 8 pole isolator 25A 6 pole isolator 25A 8 pole isolator 32A 6 pole isolator 32A 8 pole isolator 40A 6 pole isolator 40A 8 pole isolator 63A 6 pole isolator 63A 8 pole isolator 80A 6 pole isolator 80A 8 pole isolator IP65 20 Amp enclosed switches 2 pole on-off 90 4 pole on-off 90 2 pole changeover with centre off 4 pole changeover with centre off 3 pole motor reversing Other versions available IP66 Enclosures Complete with Din rail EN11C EN12C EN13C EN14C EN15C EN16C EN17C EN18C EN19C EN20C EN21C EN23C EN24C EN25C TB01C TB02C TB03C TB06C TB07C TB08C TB09C TB11C TB12C TB13C TB14C TB17C TB18C TB19C DR01C Enclosure + DIN Rail (75x125x75) Enclosure + DIN Rail (125x125x75) Enclosure + DIN Rail (125x125x100) Enclosure + DIN Rail (125x175x75) Enclosure + DIN Rail (125x175x100) Enclosure + DIN Rail (125x175x125) Enclosure + DIN Rail (175x175x100) Enclosure + DIN Rail (175x175x125) Enclosure + DIN Rail (175x175x150) Enclosure + DIN Rail (175x250x100) Enclosure + DIN Rail (175x250x150) Clear Lid Enclosure + DIN Rail (125x125x75) Clear Lid Enclosure + DIN Rail (125x175x100) Clear Lid Enclosure + DIN Rail (125x175x150) Cable terminals 10 x 2.5 terminals + 10 markers 10 x 4mm terminals + 10 markers 5 x 10mm terminals + 10 markers 2 x end plates, end stops, separators, 4mm earth, 1 x neutral +10 markers 3 x fuse holders 5 x 4mm blue neutral terminals 5 x 4mm green/yellow terminals 100 x 2.5mm terminals 100 x 4mm terminals 100 x 10mm terminals 50 x 16mm terminals 100 x 4mm earth terminals 100 x 2.5 terminal markers 100 x 2.5 terminal end brackets 1m length of slotted din-rail IP65/66 Terminal Box Footswitch FT01C Footswitch TB20C TB30C TB31C TB32C TB33C Enclosure c/w 5 x 4mm terminals + 1 x 4mm earth & end stop 88 x 88 x 53mm Enclosure, C/W 5 x 2.5mm terminals 20A 98 x 98 x 61mm Enclosure, C/W 5 x 4mm termianls 25A 119 x 139 x 70mm Enclosure, C/W 5 x 4mm terminals 32A 125 x 167 x 82mm Enclosure, C/W 5 x 8mm terminals 50A
5 pointofsale products solar product range TRUE DC Isolators Available from IMO is our True DC Isolator that has been specifically developed for arduous DC disconnect applications, the IMO range of solar Isolators features an operator independent trigger ratchet mechanisim resulting in switching times of less than 5ms. High reliability knife edge contacts and long arc cooling chambers ensure safe and effective isolation of DC voltages within solar installations. Available in 2 to 8 pole versions in a wide variety of mounting and handle configurations, the IMO Solar Isolator range is suitable for most OEM or site installation applications. Pack Qty SI01C 12 Amp 700V DC 2 pole 1 SI02C 16 Amp 800V DC 2 pole 1 SI03C 20 Amp 700V DC 2 pole 1 SI04C 25 Amp 600V DC 2 pole 1 SI05C 32 Amp 600V DC 2 pole 1 SI06C 16 Amp 800V DC 4 pole 2 string 1 SI07C 20 Amp 700V DC 4 pole 2 string 1 SI08C 25 Amp 600V DC 4 pole 2 string 1 SI09C 32 Amp 600V DC 4 pole 2 string 1 Solar Connectors Mobile connectors are used to connect PV panel in series. They also link lengths of cabling and allow connection to Branch and Panel connectors. Branch connectors are used to link multiple strings together allowing, for example, a 2 pole (single string) DC isolator to switch both strings at the same time. Panel connectors mount on solar string boxes, enclosed DC isolators and any other enclosed DC switching device allowing easy connection to the rest of the PV system. Key features: V DC 30A Rated - For 4-6mm 2 Cables - Secure Easy Clip and Release Systems - IP67 Protection - UL94-5VA Fire Protection - Class 2 protection Pack Qty SC01C Male Mobile Connector 5 SC02C Female Mobile Connector 5 SC03C Male Panel Connector 5 SC04C Female Panel Connector 5 SC05C MFF / FMM Branch Connector 1 Pair SC06C Male Connector metal insert 10 SC07C Femal Connector metal insert 10
6 also available from the world s finest From a single product to a complete application solution, IMO has the product range and knowledge to meet today s most demanding application requirements. The IMO Automation and Controls range fully addresses the sense, control and switch demands of today s factory automation and control environment. In terms of choice, the IMO line-up is peerless, offering everything today s engineer needs. From circuit protection and panelware to PLCs and AC drives. The first company in Europe to do so, IMO gives a no-quibble three year warranty on the majority of its electronics based control components and a five year warranty on its successful range of IMO Jaguar Drives. IMO Electronics is at the leading edge of electro-mechanical PCB component technology, with a range of highly specified products designed to meet the most demanding applications. The company offers one of the most competitive, high quality and comprehensive PCB relay and Terminal Block connector ranges available, supported by sophisticated IT systems and infrastructure. The Electronics Division at IMO is perfectly positioned to meet all vendor and administration reduction requirements. All products are manufactured to IMO s defined specification applying rigorous quality assurance and reliability standards. IMO products are built to comply with all relevant international approvals. Cam Switches Din Terminals Enclosures Isolators & Switch Fuses MCB & RCD Motor Circuit Breakers Motor Control Gear Panel Meters Power Supplies Relays Signal Conditioning Sockets Timers Fieldbus remote I/O HMI Intelligent Relays Limit Switches Photoelectric Switches PLCs Proximity Switches Safety Limit Switches Signal Conditioning Temperature Controls Jaguar VXG kW Jaguar VXR kW Jaguar CUB 0.4-4kW Audible devices PCB Terminal blocks Relays - automotive Relays - power Relays - signal DC Isolators High Isolation Relays Junction Boxes Terminals IMO Point Of Sale products are now being distributed worldwide IMO Precision Controls Limited 1000 North Circular Road, Staples Corner, London NW2 7JP UK Tel: +44 (0) Fax: +44 (0) Web: imo@imopc.com
Large Frame IEC Contactors
Large Frame IEC Contactors Bulletin 100-E PUBLIC Copyright 2017 Rockwell Automation, Inc. All Rights Reserved. 1 Changing Applications for Contactors There are fewer and fewer traditional large motor starting
More informationSwitches 6/1. 6/4 Introduction. 6/5 5TE8 control switches. 6/7 5TE4 8 pushbuttons. 6/9 5TE8 On/Off switches. 6/11 5TE1 switch disconnectors
6/4 Introduction 6/5 5TE8 control switches 6/7 5TE4 8 pushbuttons 6/9 5TE8 On/Off switches 4 6/11 5TE1 switch disconnectors 6 6/1 Switch to manual? Wherever electrical systems need to be switched on or
More informationIMS Control & EPR, We keep your motors running ABB s new control & protection devices up to 18.5 kw / 20 hp
IMS Control & EPR, 2010 01 29 We keep your motors running ABB s new control & protection devices up to 18.5 kw / 20 hp October 27, 2010 1SBC101089D0201 ABB s new control and protection devices Up to 18.5
More information3RA13, 3RA14 Contactor Assemblies
RA1, RA Contactor Assemblies RA1 complete units,... kw Overview The RA1 reversing contactor assemblies can be ordered as follows: Sizes S00 to S Fully wired and tested, with mechanical and electrical interlock
More informationSMARTSCAN INFORMATION
SMARTSCAN INFORMATION RY4 SERIES SAFETY RELAYS HANDBOOK Smartscan Ltd, Pywell Road, CORBY, NN17 5XJ, UK, Tel: +44 (0) 1536 401313, Fax: +44 (0) 1536 268954, Email: sales@smartscan.com, www.smartscan.co.uk
More informationAllen-Bradley Bulletin 100 Contactors
Allen-Bradley Bulletin 100 Contactors An integrated portfolio of IEC Contactors that save panel-space and energy Features and Benefits: Direct-on-line and reversing contactors Built-in surge suppression
More informationDisconnect Switches. Safe Switching and Disconnecting
IB105-UK_U1_U4_Pfade.indd 2-3 14.04.2005, 16:51:30 Disconnect Switches Safe Switching and Disconnecting Disconnect Switches from Salzer are hand-operated switchgear for main circuits and are offered as
More informationExercise 1-4. Contactors and Control Relays EXERCISE OBJECTIVE DISCUSSION OUTLINE DISCUSSION
Exercise 1-4 Contactors and Control Relays EXERCISE OBJECTIVE Identify the characteristics of control relays and contactors. DISCUSSION OUTLINE The Discussion of this exercise covers the following points:
More informationMicro Contactor MA Series
Relay-sized contactor, making it the world s smallest >3mm contact clearance acc. to IEC 60335-1 for Safety Applications Reversing contactor with mechanical interlock 3 Pole and 1 Aux. Contact NO or NC
More information3RV1 Circuit-Breakers
SIRIUS 3R Description Mountable accessories 3RV1 Circuit- Breakers Circuit-breaker S00 with mountable accessories 3 2 1 5.1 NSK-7715a 4 Circuit-breaker S0 with mountable accessories 1 7 3 5.2 2 6 NSK-7716a
More informationMSR Level Control Relay Module Operating Instructions for Level Control Relay Module Model: MSR
Operating Instructions for Level Control Relay Module Model: MSR MSR Operation Instructions Rev. Apr 07 Page 1/8 1. Note Please read and take note of these operating instructions before unpacking and commissioning.
More informationMAIN PRODUCTS. To provide value product which satisfy customer in Quality, Reliability, Performance and Durability.
ELECTROPLATING To provide value product which satisfy customer in Quality, Reliability, Performance and Durability. To strive continuously to improve quality through Kaizen, employee safety & motivation,
More informationElectrical Demand Specification (Reference SOP: )
Project: Equipment Description: Location: Equipment No.: Project No: Protocol No.: Content Index 1. GENERAL...3 Design Standards...3 1.1. Standards...3 2. DESIGN...3 2.1. Safety...3 2.2. Circuit protection...3
More informationOVERLOAD RELAYS POWER & ACTUATION PROVEN. series
POWER & ACTUATION OVERLOAD RELAYS series Need reliable, accurate overload and phase-loss protection for your motors? c3controls Series Bimetallic Overload Relays provide unmatched protection and can be
More informationRCD Fused Connection Unit Model: RCD10WPV. RCD Double Sockets Models: RCD05WAV, RCD06WPV, RCD07MAV, RCD08MPV. Installation & Operating Instructions
RCD Fused Connection Unit Model: RCD10WPV RCD Double Sockets Models: RCD05WAV, RCD06WPV, RCD07MAV, RCD08MPV Installation & Operating Instructions General The Timeguard range of RCDs provides protection
More informationMOTOR PROTECTION CIRCUIT BREAKERS
MOTOR PROTECTION CIRCUIT BREAKERS PAGE -2 PAGE -2 SMA Thermal trip adjustment ranges 9-32A (5 choices) Breaking capacity Icu at 400V: 50kA Suitable for mounting in consumer switchboards with minimum 58mm
More informationßCompliant with Amendment 3 ßBSEN for easy cabling. accommodate RCBOs. meeting current standards
CHINT EUROPE (UK) LTD Chint Metal Consumer Units ßCompliant with Amendment 3 of BS 7671 : 2008 Regulation 421.1.201 ßBSEN 61439-3 3 to 36 Ways are Standard Specials to Customer Requirements ß 1mm steel
More informationASCO 920 Remote Control (RC) Switches
Maximum reliability and excellent value ASCO 920 Remote Control (RC) Switches ASCO 920 Remote Control Switch in Type Enclosure The ASCO 920 is designed as a feeder disconnect switch for load capacities
More informationENERGY AND AUTOMATION
ENERGY AUTOMATION SINCE 1922 The first LOVATO Electric headquarters was established in Bergamo, Italy, in 1922: the starting point of a great industrial adventure. THE STORY OF A FAMILY, THE SPIRIT OF
More informationExperiment #2 PLC Input Output Wiring Methods. OBJECTIVES After successfully completing this laboratory, you should be able to:
Experiment #2 PLC Input Output Wiring Methods OBJECTIVES After successfully completing this laboratory, you should be able to: Read and explain the nameplate of DELTA s PLC DVP Series Model. Make different
More informationRotary switches T and switchdisconnectors. reliable switching, disconnection, control and operation
Rotary switches T and switchdisconnectors P for safe and reliable switching, disconnection, control and operation The high-performance, robust and compact rotary switches T and switchdisconnectors P are
More informationSIRIUS Motor Management and Control Devices
Overview is a flexible, modular motor management system for motors with constant speeds in the low-voltage performance range. It optimizes the connection between the control system and motor starter, increases
More informationArtistic Licence. Rail-Switch II. User Guide. Rail-Switch II User Guide. Version 5-5
Artistic Licence Rail-Switch II User Guide Version 5-5 Please read these instructions before using the product. This product has been designed & manufactured for professional use only. It should only be
More informationMini contactors. K 3-pole contactors for motor control, 6 and 9 A Utilisation category AC-3 Control circuit : a.c. a.c. control contactors (1)
K 3-pole contactors for motor control, 6 and 9 A Utilisation category AC-3 Control circuit : a.c. c LC-K060ii a.c. control contactors () Standard power ratings Rated Type of Instantaneous Basic reference.
More informationMini Contactors. Mini Contactor Relays 4-pole 20 Auxiliary Contact Blocks. Interface Contactor Relays. Mini Contactors 22 Auxiliary Contact Blocks
Mini Contactors Mini Contactor Relays 4-pole 20 Auxiliary Contact Blocks Interface Contactor Relays Mini Contactors 22 Auxiliary Contact Blocks Mini Contactors With Fast On Tab Connectors 24 Mini Contactors
More informationLady. Stilo. Pendant Station
Direct Lady Stilo MPA Metal Compact Joystick Station Main Power Circuit 1 row 1-3 buttons dust-proof buttons cable entry top side 1 row 2-12 buttons dust-proof buttons cable entry top or bottom side 1
More informationCS7 Industrial Control Relays
CS7 Industrial Control Relays Reliable, general purpose relays for heavy duty applications The base four pole CS7 relay can be expanded up to twelve poles with the addition of front and side mount auxiliaries
More information63 to 125 A. Functions. Conformity standards. General characteristics. Changeover switches SIRCO VM1 changeover switches.
comut_004_a_1_cat Changeover switches switches 63 to 125 A switches are manually operated three or four pole switches. They provide, source inversion or switching under load between two low voltage power
More information920 Remote Control (RC) Switches
920 Remote Control (RC) Switches ASCO is the global leader in power switching and controls ASCO 920 PRODUCT SPECIFICATIONS SWITCH ONLY (PANELBOARD MOUNTING) 1,2,3 () DIMENSIONS, IN.(MM) WIDTH HEIGHT DEPTH
More informationControl & Automation Products
Control & Automation Products Whether it is inside your panel... LED Machine Lighting Barriers HMIs Programmable Logic Controllers Power Supplies HMI + PLC Emergency Stops Relays Terminal Blocks Timers
More informationCLIPLINE complete. The modular terminal block system for all applications
CLIPLINE complete The modular terminal block system for all applications CLIPLINE complete All connection technologies, one system With CLIPLINE complete, the unique modular terminal block system from
More information1.1. Contactors and Starters... Contents Description Relays and Timers... Miniature Controls... Manual Motor Protectors. XT IEC Power Control
. Contents Description Relays and Timers......................... Miniature Controls......................... Contactors and Starters.................... Thermal Overload Relays.................... C440/XT
More informationMotor Control Products Selection Guide
MKING MODERN LIVING POSSIBLE Motor Control Products Selection Guide Contactors, Relays, and Circuit Breakers www.danfoss.com/ia c o n t e n t s Minicontactors CI 5 Thermal Overload Relays TI 9C for Minicontactors
More informationCONTROL PANEL WIRING SPECIFICATIONS
CONTROL PANEL WIRING ISSUE STATUS FIRST REV DESCRIPTION DATE 001 1 ST ISSUE 22/04/2014 002 1 ST AMMENDMENT 10/03/2017 003 2 ND AMMENDMENT 08/09/2017 THIS DOCUMENT IS DESIGNED TO COVER ALL APPLICATIONS,
More informationMODULES FOR SAFETY AND MONITORING
MODULES FOR SAFETY AND MONITORING Woertz AG Hofackerstrasse 47, P.O. Box 948, CH-43 Muttenz, Switzerland Tel. ++4 6 / 466 33 33, Fax ++4 6 / 46 96 06 http://www.woertz.ch Woertz-USA 5 Discovery Drive,
More informationRiLine Compact The smart power distribution system
RiLine Compact The smart power distribution system 2 Power distribution in a confined space Rittal are the leading suppliers of reliable power distribution and backup systems for controlgear. The new RiLine
More informationWiring diagrams. Content. Information for reading and graphic symbols... 5/2. Wiring diagrams of the circuit-breakers... 5/3
Wiring diagrams Content Information for reading and graphic symbols... 5/2 Wiring diagrams of the circuit-breakers... 5/3 Electrical accessories... 5/4 5/1 Information for reading and graphic symbols State
More informationJ7MN. Ordering Information. Motor Protection Circuit Breaker. Model Number Legend. MPCB system. Options. Motor Protection Circuit Breaker J7MN I-1
Motor Protection Circuit Breaker J7MN ) MPCB system Rotary and switch types Rated operational current 32 A, 63 A and 00 A Switching capacity up to 00 ka/400 V Fixed short-circuit release = 3 x I u Overload
More informationProduct Family: Electro Mechanical Relays Number: AN-LC-008
APPLICATION NOTE THIS INFORMATION PROVIDED BY AUTOMATIONDIRECT.COM TECHNICAL SUPPORT These documents are provided by our technical support department to assist others. We do not guarantee that the data
More informationL.V. Systems & Solutions
GE Energy Industrial Solutions L.V. Systems & Solutions Residential Components & Distribution Boards Home & Building Automation Industrial Breakers General Purpose Enclosures System Enclosures Control
More informationIssued February DATA SHEET 5SX2 MCB. Based on Siemens Industrial Control Catalog
Issued February 2011 DATA SHEET 5SX2 MCB Based on Siemens Industrial Control Catalog General Data Trip characteristics Tripping characteristics acc. to EN 60 898 Tripping characteristic A, -5 Type A characteristic
More informationProducts and solutions for machine builders (OEM)
Products and solutions for machine builders (OEM) www.lovatoelectric.com Tra dition and Innovation Since 1922 The first LOVATO Electric headquarters founded in Bergamo (Italy) in 1922: the starting point
More informationINSTALLATION & OPERATING MANUAL
INSTALLATION & OPERATING MANUAL IC 90 CHECK CONTENTS Package should contain.. Meter. Fixing Brackets (). Installation and Instruction Manual. The IC 90 meter is the latest kwh meter in the 900 series from
More informationTP&N DISTRIBUTION BOARD TYPE B RANGE
GROUP Now included in the range: Extension Boxes Metering Kits Surge Suppression and more! TP&N DISTRIBUTION BOARD TYPE B RANGE A comprehensive distribution board range for modern commercial & industrial
More informationAThink future. Switch to green. Mini Panel Board. Cost-effective, space-saving board up to 400A.
www.moeller.co.uk Mini Panel Board Cost-effective, space-saving board up to 400A Product Catalogue and Selection Guide Mini Panel Board Miniature Circuit Breakers Moulded Case Circuit Breakers XBoard Consumer
More informationApproved Standards. Motor Protection Circuit Breaker (MPCB) J7MN. MPCB system (motor protection CLASS 10) Auxiliary contact modules.
Motor Protection Circuit Breaker (MPCB) J7MN MPCB system (motor protection CLSS 0) Rotary and switch types Rated operational current = 2, 25, 50 and 00 Switching capacity up to 2.5 = 00 k/400 V Fixed short-circuit
More informationUSER MANUAL INSTALLATION MANUAL. Isolation transformers. ITR Isolation Transformer 7000 W 230V/32A
USER MANUAL INSTALLATION MANUAL Isolation transformers ITR000702000 Isolation Transformer 7000 W 230V/32A Victron Energy B.V. The Netherlands General phone: +31 (0)36 535 97 00 Customer support desk: +31
More informationENERGY AND AUTOMATION
ENERGY AUTOMATION SINCE 1922 The first LOVATO Electric headquarters was established in Bergamo, Italy, in 1922: the starting point of a great industrial adventure. THE STORY OF A FAMILY, THE SPIRIT OF
More informationQuantum III. Compact DC Drive Package. Slitter DC Drive Package. Quantum III
Compact DC Drive Package The delivers a DC drive package that integrates the intelligence of the Mentor II with a space saving design that incorporates many accessories typically required in the North
More informationJaguar F-TYPE CAM 16. Dual Camera interface for select 16+ Jaguar vehicles NTV-KIT746 BHM 05/31/16 NTV-DOC259
3950 NW 120 th Ave, Coral Springs, FL 33065 TEL 561-955-9770 FAX 561-955-9760 Jaguar F-TYPE CAM 16 Dual Camera interface for select 16+ Jaguar vehicles NTV-KIT746 BHM Overview Jaguar F-TYPE CAM 16 interfaces
More informationRCDs RCBOs MCBs Isolating Switches Switchboards
RCDs RCBOs MCBs Isolating Switches Switchboards 1300 722 275 F: 1300 738 717 RCD 4 Pole 6KA RCDs monitors at all times the current flow and will cut the electrical supply in case of an imbalance. Suitable
More informationRUC industrial relays of small dimensions
Contact data Number and type of contacts Contact material Rated / max. switching voltage Min. switching voltage Rated load Min. switching current Max. inrush current Rated current Max. breaking capacity
More informationIndustrial relay system RIFLINE complete
Industrial relay system RIFLINE complete Easy handling RIFLINE complete relay system You can carry out all standard relay applications using the RIFLINE complete industrial relay system. It doesn't matter
More information48 Series 4C Series 58 Series Relay Interface Modules 15.8 mm wide Relay Interface Modules 15.8 mm wide
The FINDER Relay Interface Module ADVANTAGE Take advantage of a pre-assembled unit and make your job easier One Part Number combines relay, socket, clip and LED/suppression module UL listed devices with
More informationSeries CA7 Contactors
Series Rugged, space saving and modular Sprecher + Schuh s newest contactor for applications up to 6HP Over years of design experience has produced Sprecher + Schuh s seventh generation contactor line.
More informationRevolutionizing control wiring
SmartWire-DT Panel Wiring Solutions Revolutionizing control wiring 797-6925 Fax: (215) 221-1201 www.royalelectric.com SmartWire-DT Changing the way panels are wired. Reduce cost throughout the value chain.
More informationDevice manual AS-i PowerSwitch ZB0028 ZB0040
Device manual AS-i PowerSwitch ZB0028 ZB0040 System AS-i Page 1 of 16 Device manual POWERSWITCH ZB0028 ZB0040 Date: 04/02/02 Contents 1. Views... 3 1.1 Top view... 3 1.2 Front view... 4 1.3 Bottom view...
More informationSchrack Switchgear. Switches Enclosures Industrial Control LED Lighting Connectors Audio-Visual Alarms Military Standard Transport Cases
Schrack Switchgear Switches Enclosures Industrial Control LED Lighting Connectors Audio-Visual Alarms Military Standard Transport Cases Switches Plus Components Switches Plus Components, a family owned
More informationSelection Guide. Control Circuit and Load Protection. Allen-Bradley 1489-M2C020
Selection Guide Control Circuit and Load Protection Circuit Protection Portfolio 1489-M Circuit Breakers Approved for branch circuit protection in the United States and Canada, and certified as Miniature
More informationVC3000 Series Line Voltage Switching Relay Pack Controllers Installation Guide
Beyond Comfort VC3000 Series Line Voltage Switching Relay Pack Controllers Installation Guide August 10 th, 2010 (For Commercial and Lodging HVAC Fan Coil Applications) 028-0296-R1-LIT-VC3000-E01 Index
More informationJaguar F-TYPE CAM Dual Camera interface for select 14+ Jaguar vehicles NTV-KIT589
3950 NW 120 th Ave, Coral Springs, FL 33065 TEL 561-955-9770 FAX 561-955-9760 Jaguar F-TYPE CAM Dual Camera interface for select 14+ Jaguar vehicles NTV-KIT589 BHM Overview Jaguar F-TYPE CAM interfaces
More information5.1. Motor Protection and Monitoring. Contents. Product Overview. Monitoring Relays. D64R Series Digital Ground Fault Relays...
.1 Ground Fault Relays and Monitors Contents Description Current.................. Phase................... Voltage.................. Ground Fault Relays and Monitors D64R Series Digital Ground Fault Relays....
More information3RM1 Hybrid Starters 6SIRIUS. contents. Industrial Controls Product Catalog 2017
3RM1 Hybrid Starters Industrial Controls Product Catalog 2017 Section contents 3RM1 Compact - Hybrid Starters Overview /2 General Data /3 Selection and ordering data /4 Accessories /5 - /9 Technical Data
More informationTRC-190 User s Manual
First Edition, November 2008 www.moxa.com/product 2008 Moxa Inc. All rights reserved. Reproduction without permission is prohibited. The software described in this manual is furnished under a license agreement
More informationContact protection relay
Contact protection relay Ordering details SVR 450 08 F0000 The protects sensitive control contacts from excessive load. It can be used with latching function or without. Bounce time of control contacts
More informationControls Enclosed Non-Combination Starters - PESW Series
NEMA 4/4X Non Metallic Enclosure Product Features WEG offers non-reversing and non-combination NEMA-4X magnetic starter up to 75HP at 460V. Featuring components that meet IEC design standards and UL horsepower
More informationDiscover TeSys U motor starters open version Starter-controller Non-reversing power bases
Discover TeSys U motor starters open version Starter-controller Non-reversing power bases DB0 DB0 LUB, LUB LUB 0, LUB 0 Two types of bases are available, each in two versions: b LUB, LUB Standard power
More informationINSTALLATION DKM-409 NETWORK ANALYSER WITH HARMONIC MEASUREMENT AND SCOPEMETER. Before installation:
DKM-409 NETWORK ANALYSER WITH HARMONIC MEASUREMENT AND SCOPEMETER The DKM-409 is a precision instrument designed for displaying various AC parameters in 3-phase distribution panels. Thanks to its isolated
More informationWMS SUPPLEMENTARY PROTECTORS
WMS Supplementary Protectors Overview WMS SUPPLEMENTARY PROTECTORS Product Specification The WMS Supplementary Protector is a dual-rated product for both AC and DC supplies, in accordance with UL 1077
More informationSECTION SOLID-STATE REDUCED VOLTAGE STARTERS
SECTION 26 29 13.16 PART 1 - GENERAL 1.1 THE REQUIREMENT A. General: The CONTRACTOR shall provide solid-state reduced voltage motor starters, complete and operable, in accordance with the Contract Documents.
More informationELECTRICAL CONTROL SYSTEM COMPONENTS
Module - 2 ELECTRICAL CONTROL SYSTEM COMPONENTS Lecture - 1 MECHANICAL SWITCHES Shameer A Koya EEET 221 : Electrical Control Systems. Module 2 - Objectives State the functions of control system components
More informationRUC industrial relays of small dimensions
with adaptor (V) with adaptor (H) Power relays of general application AC and DC coils Mounting: in sockets; 35 mm rail mount acc. to PN-EN 60715; on panel; PCB Versions: faston 187 (4,8 x 0,5 mm); faston
More informationCI-tronic Reversing contactor Type RCI
Data sheet CI-tronic Reversing contactor Type RCI RCI reversing contactors are designed for demanding forward/reverse control of three-phase AC motors. The zero cross switching method ensures very fast
More informationUniversal Motor Controller UMC22-FBP. Excellent motor protection and control ATEX ABB
Universal Motor Controller UMC-FBP Excellent motor protection and control ATEX ABB FieldBusPlug: the concept ABB s communicative product family comprises a wide range of switching, controlling and automation
More informationSED2 Variable Frequency Drives with Electronic (E) Bypass Options
SED2 Variable Frequency Drives with Electronic (E) Options Description The E- Options are companion packages for the family of SED2 Variable Frequency Drives (s). For information on the family of SED2
More informationC5 Series Stainless Steel Photoelectric
C5 Series Stainless Steel Photoelectric Part Number Sensing Range M5 (5 mm) stainless steel - DC 14 models available Diffuse and through-beam styles Long operating distances Compact stainless steel housing
More informationflare MOVE Relay modules Modular design H 10/02
flare MOVE Relay modules Modular design 0112.0 H 10/02 Relay modules flare MOVE Plug-in relays Overall width: 15.8 mm plug-in relay single changeover contact / 2 changeover contact Dimensions (mm): B x
More informationMCS-2015 Basic power supply for on-off and emergency 115 VAC Electrak 1 stop. 115 VAC or 230 VAC input. 230 VAC Electrak 10 Electrak 100
Whether you plan to operate from a simple pushbutton or a programmable controller, the MCS-2000 series controls can make your system easy to design and install and simple to operate. Designed to drive
More informationRB60 RANGE. Miniature circuit breakers
RB60 RANGE Miniature circuit breakers POWER 2015 RB60 range Miniature circuit breakers Miniature circuit breakers for circuit protection The miniature circuit breakers RB60 are designed for the protection
More informationSmartWire-DT In panel and on machine wiring solutions. Revolutionizing in-panel control wiring and on-machine connection of sensors and actuators
SmartWire-DT In panel and on machine wiring solutions Revolutionizing in-panel control wiring and on-machine connection of sensors and actuators SmartWire-DT Changing the way panels... Reduce cost throughout
More informationOvervoltage Protection
Overvoltage Protection Weidmuller has a complete line of overvoltage protection devices to effectively stop the harmful effects of electrical overvoltage and electrical noise. There is strong potential
More informationOPERATING INSTRUCTIONS 7 SERIES STATIC GENERATORS
OPERATING INSTRUCTIONS 7 SERIES STATIC GENERATORS GB Contents Page 1 Introduction 4 2 Safety 5 3 Use 6 4 Checking on Delivered Equipment 6 5 General Specification and Dimensions 7 6 Positioning 10 7 Operating
More informationCircuit Breakers Type CTI 25M, CTI 45MB
Data sheet Circuit Breakers Type CTI 25M, CTI 45MB Circuit breakers for short circuit and overload protection of motor applications cover the current range 0.1 45 A (AC-3 rating). The product range is
More informationSMARTSCAN INFORMATION
SMARTSCAN INFORMATION SL4 (014) SERIES SAFETY LIGHT CURTAINS HANDBOOK Smartscan Ltd, Pywell Road, CORBY, NN17 5XJ, UK, Tel: +44 (0) 1536 401313, Fax: +44 (0) 1536 268954, Email: sales@smartscan.co.uk,
More informationCS8 Industrial Control Relays
CS8 Industrial Control Relays Despite increasing complexity, control systems and installations must become increasingly compact. And the CS8 Miniature Relay System packs maximum performance into minimum
More informationInductive Proximity Sensors
CARLO GAVAZZI A u t o m a t i o n C o m p o n e n t s Inductive Proximity Sensors Housings to Fit Your Needs Cylindrical Rectangular Flat pack Slotted Various Outputs Transistor SCR Analog MOSFET NAMUR
More informationinformation service Pag.1
Pag.1 TO SCAME CLIENTS List of new available products (Refer to Commercial Dept for item codes and prices) DATATEL Series Cat. 6 New products in DATATEL Series Components for RJ45 cat. 6 trasmission systems
More informationPC-200-LLC-GM INSTALLATION INSTRUCTIONS. Revision A1 Rapid City, SD, USA, 10/2009 II_PC-XXX-LLC-GM_A1
INSTALLATION INSTRUCTIONS Revision A1 Rapid City, SD, USA, 10/2009 MODELS PC-100-LLC-GM PC-200-LLC-GM II_PC-XXX-LLC-GM_A1 2880 North Plaza Drive, Rapid City, South Dakota 57702 (800) 843-8848 (605) 348-5580
More informationFAZ Supplementary Protectors, FAZ Miniature Circuit Breakers, P2 Disconnect Switches Overview
FAZ Supplementary Protectors, FAZ Miniature Circuit Breakers, P2 Disconnect Switches Overview Supplementary Protectors / Miniature Circuit Breakers Page System overview 10/003 10/001 Supplementary protectors
More informationMiniature Circuit-Breaker IEC Series 8562
> 1 to 3 pole versions > Rated current from 0.5... 40 A > 6 or 10 ka breaking capacity to DI VDE 0641, respectively E 60898 > Isolating Function to E 60947-2 > Permanently set thermal and magnetic trips
More information24973 Circuit Breaker MINIATURE CIRCUIT BREAKER, 440VAC, 10A, CIRCUIT BREAKER TYPE: STANDARD
United States 24973 Circuit Breaker MINIATURE CIRCUIT BREAKER, 440VAC, 10A, CIRCUIT BREAKER TYPE: STANDARD Image not available Product Information Features and Specifications Approvals: IEC 60947-2 Rated
More informationMotor protection relays
Thermal overload relays for currents between 0.09 and 420A Electronic thermal overload relays for currents between 0.4 and A Electronic thermal overload relays with selectable tripping class: 5--20-30
More informationRedline. Extensions. Display contacts. Function S. Display contact CA. Function. Add-on Devices T3.2
Redline Extensions All MCB s (except G20), RCCB s (except Delta B) & RCBO s are designed to accept the same family of extensions. Main device ON Normal working status Addon Devices The extensions intended
More informationTimers. GT5Y Series ON Delay Timers. ±3% maximum (over 10 to 50 C, reference temperature 20 C) Setting Error. ±10% maximum
GT5Y GT5Y Series ON Delay Key features: 4PDT, 3A or DPDT, 5A contacts 4 time ranges Repeat error ±0.2% maximum Control settings by hand or screwdriver Power ON and timing out LED indicators Uses the same
More informationMAINS DISTRIBUTION UNIT MDU14-CO
MAINS DISTRIBUTION UNIT MDU14-CO Dual Input Auto Changeover 14 Output Mains Distribution Unit. Handbook Television Systems Limited. Vanwall Road, Maidenhead, Berkshire, SL6 4UB Telephone +44 (0)1628 676200,
More informationATS-16 HV USER MANUAL. Automatic Transfer Switch 16A / 230Vac V090318
ATS-16 HV Automatic Transfer Switch 16A / 230Vac USER MANUAL V090318 SAFETY Intended use The ATS-16 HV device serves as a power source selector to provide improved power supply for connected loads. ATS-16
More informationDEEP SEA ELECTRONICS PLC
COMPLEX SOLUTIONS MADE SIMPLE DEEP SEA ELECTRONICS PLC DSE705 ATS CONTROL MODULE OPERATING MANUAL Deep Sea Electronics Plc Highfield House Hunmanby North Yorkshire YO14 0PH ENGLAND Sales Tel: +44 (0) 1723
More informationWeathersafe Vision. Installation & Operating Instructions
Weathersafe Vision Installation & Operating Instructions IP66 Products covered by these instructions 1 TGVL01 TGVL02 TGVL03 TGVL05 TGV101N TGV201N TGV104N Single Gang 2-Way Switch [SP] 10AX (Fluorescent
More informationSet up and verify the operation of basic motor starters. Understand the purpose of a separate control circuit.
Exercise 3-1 Motor Starters EXERCISE OBJECTIVE Set up and verify the operation of basic motor starters. Understand the purpose of a separate control circuit. DISCUSSION OUTLINE The Discussion of this exercise
More informationTimers & control relays
7% Timers & control relays J PCB mount relays Finder J-1 3 Plug-in relays Finder J-2 8 Power relays Finder J-7 Stepping relays Finder J-9 Modular contactors Finder J-10 Relay interface modules Finder J-11
More information