2 Distribution List 1 1. Member (PS) Central Electricity Authority Sewa Bhawan, R.K.Puram, New Delhi FAX : Member Secretary Southern Regional Power Committee 29, Race Course Cross Road Bangalore FAX : Director (Grid Transmission and Management) Transmission Corp. of Telangana Ltd. (TSTRANSCO) Vidyut Soudha, Khairatabad Hyderabad FAX : Director (Trans. & System Op.), Kerala State Electricity Board Ltd. Vidyuthi Bhawanam, Pattom, P.B. No Thiruvananthapuram FAX : Director (Power) Corporate Office, Block I Neyveli Lignite Corp. Ltd. Neyveli, Tamil Nadu FAX : Chief Engineer (PSPA-2) Central Electricity Authority Sewa Bhawan, R.K.Puram, New Delhi FAX : Director (Transmission) Transmission Corp. of Andhra Pradesh Ltd. (APTRANSCO) Vidyut Soudha Hyderabad FAX : Member (Transmission) Karnataka State Power Transmission Corp.Ltd. Cauvery Bhawan Bangalore FAX : Member (Distribution), Tamil Nadu electricity Board (TNEB) 6 th Floor, Eastern Wing, 800 Anna Salai, Chennai FAX : Superintending Engineer I First Floor, Electricity Department Gingy Salai Puducherry FAX : /
3 Distribution List 2 (Connectivity/Long-term Access Applicants) 1. Sh. B. S. Yadav Chief Executive Officer R S India Global Energy Limited 3 rd Floor, GL Complex, Opp. Udyog Vihar (Dundahera), Old Delhi Gurgaon Road, Gurgaon , Haryana 3. Sh. C R Srinivas Director & CTO Enerfra Projects (India) Private Limited, 18/6, Executive Chambers, Cunningham Road, Bangalore , 5. Sh. Dheeraj Jain AGM Regulatory Affairs Regen Wind Farm (Vagarai) Pvt. Ltd. C/4, No. 22, Vaidya Rama Iyer Street, T Nagar, Chennai Sh A. K. Loganathan Technical Director Surana Power Limited No: 29, Whites Road, 2nd floor, Royapettah, Chennai Sh. Ravishankar Srinivasan General Manager - Construction Vestas Wind Technology India Pvt. Ltd. 298 Rajiv Gandhi Salai, Sholinganallur Chennai , India 2. Sh. Akhil Agarwal Associate Vice President IL&FS Tamil Nadu Power Company Ltd. 4 th Floor, B-Block, Navins Presidium, 103, Nelson Manickam Road, Aminjikarai, Chennai Sh. C Dwarakanath Senior Vice President SAMALKOT Power Limited PB No. 22, IDA Peddapuram, ADB Road, Samalkot, E.G.Dt Andhra Pradesh 6. Sh. Alok Gupta General Manager P.E. INOX Wind Infrastructure Services Ltd. INOX Towers, Plot No. 17, Sector 16A, Film City, Noida , Uttar Pradesh 8. Sh. Rakesh Rathore Asst. Vice President Srijan Energy Systems Pvt. Ltd. 102, EL Tara Building, Orchard Avenue, Hiranandani, Powai, Mumbai , Maharashtra 10. Sh. Yogesh Juneja General Manager & Project In-Charge Coastal Tamil Nadu Power Ltd. (CTNPL) 1st Floor, "Urjanidhi" 1 Barakhamba Lane, Connaught Place, New Delhi Sh. P. Bhaskar Technical Director Karnataka Power Corporation Ltd. No. 82, Shakti Bhavan, Race Course Road, Bengaluru , Karnataka
4 Minutes of 20 th Meeting of Southern Region constituents regarding Connectivity/LTA Applications of IPPs in SR held on at List of participants enclosed in Annexure- I Gurgaon 1.0 Minutes of 19 th Meeting of Southern Region constituents regarding Connectivity / Long Term Access applications The Minutes of the 19 th Meeting of Southern Region constituents regarding Long Term Access and Connectivity applications held on 29 th Dec, 2015 at NRPC office, New Delhi were circulated vide letter dated 29 th been received, the Minutes were confirmed as circulated. Feb, As no comments have 2.0 Amendment in Detailed Procedure COO(CTU) welcomed the participants and informed that, CERC has issued directions for treating long pending applications by amending the Detailed Procedure vide letter dated and also directed CTU to give wide publicity to the amendment for the information of all concerned. The amended provision states that: : CTU shall not hold any LTA application in abeyance and process the applications within the timeline prescribed in Regulation 7 of the Connectivity Regulations. If any LTA applicant requests CTU in writing for deferment of consideration of its applications or does not participate in the LTA meetings despite being invited by CTU, the application shall not be further processed. CTU shall in such cases close the applications and return the bank guarantee. In respect of applications which are already pending with CTU on request of the applicants or for their non-participation in the LTA meetings, CTU may give a notice of 15 days in writing to the concerned LTA applicants about the closure of the application. If any applicant is willing to pursue his application the same shall be processed in the next LTA meeting. If the applicant seeks further deferment of extension of application or does not respond to the notice, CTU may proceed to close the applications and return the bank guarantee
5 In view of the above CTU representative stated that Connectivity/LTA application shall not be kept on-hold/in abeyance. It was further requested that applicants should sign the necessary agreements as per the time lines mentioned in the intimation to grant of connectivity/lta Members noted the same 3.0 Long Pending Connectivity Applications In light of the new amendment, the following long pending connectivity applications were discussed: Sl. No. Applicant Location Date of Application Start Date (As per application) Connectivity/ LTA Sought (MW) 1. RS India Global Energy Limited Thirunelveli Dist,, Tamil Nadu March (Connectivity) 2. Vestas Wind Technology India Private Limited Coimbatore and Tirupur Dist, Tamil Nadu September (Connectivity) 3. IL & FS Tamil Nadu Power Company Limited Villianallur,Ariyakoshti, Kothatai Tamil Nadu April (Connectivity) 4. Enerfra Project(India) Pvt. Ltd Alluru,Kurnool District, Andhra Pradesh March (Connectivity) 3.1 M/s R.S India Global Energy Ltd CTU representative informed that R.S India Global Energy Ltd had applied for connectivity of their 270 MW generation in Thoothukudi /Tirunelveli District in Tamil Nadu. The application has been pending since Mar, No representative of M/s R.S India Global Energy Ltd was present in the 18 th and 19 th Meeting of SR for Connectivity/ LTA Applications. The representative from R.S India Global Energy
6 Ltd. was not present in the meeting also, hence looking into the recent amendment to the Detailed Procedure, as the applicant is not participating in the LTA meetings despite being invited by CTU, it was agreed to close the application 3.2 M/s Vestas Wind Technology India Private Ltd CTU representative informed that M/s Vestas Wind Technology India Private Ltd had applied for connectivity of their 150 MW generation in Coimbatore/Tiruppur districts of Tamil Nadu. The application is pending since Aug, No representative of Vestas Wind Technology India Private Ltd was present in the previous three Meetings of SR for Connectivity/ LTA Applications to update the status of the generation project. However in the 19 th meeting, it was agreed to grant connectivity to Vestas Wind Technology India Private Ltd. at Anikkadavu through Vestas Wind Technology India Private Ltd. Anikkadavu 230kV D/c line. The 230kV D/c line along with bays at both ends needs to be developed as dedicated system by the developer. The representative of M/s Vestas Wind Technology India Private Ltd informed that Watson Infrabuild Pvt. Ltd. has taken over the project and that they have already been granted connectivity by STU. Accordingly the 230 kv connectivity line is already under construction. As per prevailing CERC regulations, connectivity for the same project cannot be given at ISTS and Intra STS network. The representative of M/s Vestas Wind Technology India Private Ltd agreed to formally withdraw the application within 15 days. It was agreed to close the application. 3.3 M/s IL&FS Tamil Nadu Power Company Ltd CTU representative informed that M/s IL&FS Tamil Nadu Power Company Ltd had applied for connectivity for its Phase-II expansion of the generation project (4x600 MW) at Cuddalore. The application is pending since Mar, No representative of ITPCL was present in the 19 th Meeting of SR for Connectivity/ LTA Applications. No representative from M/s IL&FS Tamil Nadu Power Company Ltd was present in the meeting. Hence looking into the recent amendment to the Detailed Procedure, as
7 the applicant is not participating in the LTA meetings despite being invited by CTU, it was agreed to close the application 3.4 Enerfra Projects (India) Pvt Ltd CTU representative informed that Enerfra Projects (India) Pvt Ltd had applied connectivity for their 300 MW wind generation in Kurnool, AP. The application is pending since Feb, No representative of Enerfra Projects (India) Pvt. Ltd. was present in the 18 th and 19 th Meeting of SR for Connectivity/ LTA Applications. CTU representative informed that in the 19 th meeting of SR for Connectivity/ LTA Applications, grant of connectivity at 220 kv yard, owned by APTRANSCO, at 400/220 kv Gooty S/S was proposed. Representative of APTRANSCO stated that there is no space for 220kV bays at Gooty S/s however, adequate space for termination of connectivity line is available at Jammalamadugu substation which is being specifically developed for Wind Generation. Accordingly, it was agreed that the connectivity for Enerfra Projects (India) Pvt. Ltd. may be granted at Jammalamadugu(Kondapuram), APTRANSCO through Enerfra Projects (India) Pvt. Ltd. Jammalamadugu(Kondapuram) 220kV D/c line. As the representative of Enerfra Projects (India) Pvt. Ltd. was not present in the 19 th Meeting, it was agreed that matter to be deliberated further. The representative of Enerfra Projects (India) Pvt. Ltd. informed that connectivity to Jammalamadugu (Kondapuram) S/s is not convenient. The representative also informed that though the land for proposed wind farm is yet to be acquired; however, likely location is about 120 km from Jammalamadugu S/s of APTRANSCO. Hence, the proposed connectivity is economically not viable, therefore, they requested connectivity at Gooty S/s. CTU representative informed that the connectivity to Gooty S/s cannot be granted without the consent of APTRANSCO. The applicant requested for One(1) month time to get the consent from APTRANSCO for connectivity at Gooty S/S. In case of non-receipt of the above consent within the above time period, the applicant agreed that their application may be closed.
8 Members agreed for the same. 4.0 New LTA & Connectivity Applications AGM (CTU) informed that following new applications have been received since last meeting of SR for Connectivity/LTA Applications : Sl. No Applicant Location Date of Application Start Date (As per application) Connectivity /LTA Sought (MW) 1. Samalkot power Limited East Godavari Dist, Andhra Pradesh February (Connectivity) 2. Regen Wind Farm (Vagarai) Pvt. Ltd Dindigul, Tamil Nadu th March (Connectivity) 3. Regen Wind Farm (Vagarai) Pvt Ltd. Dindigul, Tamil Nadu to NR May (LTA) 4. Regen Wind Farm (Vagarai) Pvt Ltd. Dindigul, Tamil Nadu to NR September (LTA) 5. Regen Wind Farm (Vagarai) Pvt Ltd. Dindigul, Tamil Nadu to NR April (LTA) 6. Regen Wind Farm (Vagarai) Pvt Ltd. Dindigul, Tamil Nadu to NR June (LTA) 7. Inox Wind Infrastructure Services Ltd (Aynaruthu Wind Farms) Tirunelveli, Tamil Nadu September (Connectivity)
9 4.1 M/s Samalkot power Limited CTU representative informed that Samalkot power Limited has applied for connectivity of their 2214 MW Gas based combined cycle generation [6x236+3x266] in Samalkot, AP. As per the application, connectivity is required from Feb 17. The project is to be commissioned progressively from Feb 17 to June 18. Generation would be available at the step-up voltage of 400 kv. The nearest substation to the proposed project is the Vemagiri-II (PG) S/S. The Samalkot Power Limited was earlier granted Connectivity (2400 MW) & LTA (2200 MW) in Dec, However pursuant to the CERC directions in petition no.127/2012 & 128/2012, both Connectivity & LTA applications were withdrawn in Oct, As per regulation,the capacity of the transmission system for Connectivity to the nearest grid has to be adequate to sustain full load power transfer of one Unit at a time which in this case is 266 MW. However looking into the plant size & judicious utilisation of the RoW, it is proposed that the Connectivity line to the nearest grid point may be considered with 400kV Quad conductor so that subsequently when power is to be evacuated by any form of access then there is judicious utilization of RoW. CTU representative, however clarified that the 400kV D/c line with Quad conductor shall not be adequate for evacuation of entire quantum of the plant under N-1 condition. Further it was informed, mere connectivity shall not entitle power evacuation unless, the applicant obtains LTA, MTOA & STOA. Further, since MTOA & STOA are granted on the margins available in the grid and firm transfer of power is granted only with the LTA, therefore, the applicant was advised to apply for the LTA to plan transmission system that assure power evacuation & transfer to its beneficiaries. Also CTU representative pointed out that, as per preliminary examination, in order to accommodate injection from proposed generation, further strengthening will be required. CTU representative also clarified that Fault level at Generating station switchyard may be considered as 50 ka. 125 MVAR bus Reactor may be provided at Generating station switchyard and space for four (4) additional line bays and 1 Bus reactor may be kept at generating station switchyard.. As regards Transmission
10 System for Connectivity it was intimated that the under implementation 765/400kV GIS substation in Vemagiri has adequate bay space to accommodate line terminations. Representative of Samalkot Power Limited informed that the proposed lines was partly constructed as per earlier grant of Connectivity & LTA. Accordingly, representative of SPL stated that they shall be taking-up the transmission system for connectivity. Further SPL has made arrangement for start-up power with APTRANSCO system, with which some of the units are being tested for full load. Accordingly, it was proposed to grant connectivity to SPL for 2241 MW [6x236+3x266] through Samalkot Vemagiri-II (PG) 400 kv D/c Quad line. Members agreed for the same. 4.2 M/s Regen Wind Farm (Vagarai) Pvt Ltd. CTU representative informed that Regen Powertech Private Limited was earlier granted 600 MW connectivity at Pugalur 400/230kV substation in 2011 with dedicated transmission line Regen PS Pugalur 230 kv D/c (twin moose) line. In the meantime, while making the present Connectivity application, Regen Powertech Pvt. Ltd. vide letter dated has informed that they now want to develop the generation project by a group of generators (48x x1) for which Regen Powertech Private Limited shall be the lead generator. Accordingly they had requested to withdraw/surrender the earlier connectivity and has submitted fresh application for 600 MW connectivity at the same location vide application dated As per the new application the start date of connectivity is mentioned as which has already elapsed. Regen Powertech Pvt. Ltd. vide letter dated 8th July 2016 informed that the generation is scheduled progressively from March The connectivity was proposed to be granted at Pugalur 400/230kV substation through Regen PS Pugalur 230 kv D/c (Twin Moose) line under the scope of applicant. The transmission system is planned based on the prevailing Transmission Planning Criteria of CEA as per which N-1 criteria may not be applied to the immediate connectivity of wind/solar farms with the ISTS/Intra-STS grid and the wind
11 developer shall provide adequate reactive compensation so that under all dispatch scenarios Power Factor of 0.98 shall be maintained. CTU representative also informed that Regen Wind Farm (Vagarai) Pvt Ltd has submitted 4 nos of LTA applications for cumulative capacity of 240 MW ( MW) from their Wind generation project in Dindigul, Tamil Nadu. The LTA is sought progressively from May 17 with NR as target beneficiary. The aforesaid LTA shall involve power transfer from SR to NR via WR/ER. Regarding power flow from the SR to NEW Grid, it is to mention that power flow is in reverse direction from the normal prevailing power flow, therefore no constraints are envisaged. However, for power transfer on WR to NR corridor, studies indicate that 240 MW to NR can be accommodated with commissioning of Jabalpur- Orai 765 kv D/c line Accordingly, it was proposed to withdraw/close the earlier grant of connectivity and grant connectivity for 600 MW and LTA of 240 MW with the following system Transmission System for Connectivity: Regen PS Pugalur 230 kv D/c (Twin Moose) line Transmission system for LTA: WR- NR 765kV Inter-regional corridor Jabalpur- Orai 765 kv D/C line Members agreed for the same. 4.3 M/s Inox Wind Infrastructure Services Ltd. CTU representative informed that Inox Wind Infrastructure Services Ltd has applied for connectivity of their 500 MW generation in Tirunelveli, Tamil Nadu. As per the application, connectivity is required from Sept 17. The project is to be commissioned progressively from December 17 to July 18. The generation would be available at the step-up voltage of 230kV. The nearest substation to the proposed project is the existing Tirunelveli S/S However due to space constraints at existing Tirunelveli S/s, the connectivity for M/s Inox Wind Infrastructure Services Ltd. was proposed to be granted at Tirunelveli Pooling Station through 230 kv D/c (Twin Moose) line. M/s Inox Wind Infrastructure
12 Services Ltd requested that connectivity for their 500 MW wind farm may be granted with Single Moose instead of Twin Moose, as this is in conformity to the prevailing Transmission Planning Criteria of CEA as per which N-1 criteria may not be applied to the immediate connectivity of wind/solar farms with the ISTS/Intra-STS grid. M/s Inox Wind Infrastructure Services Ltd also informed that they will be constructing the 230 kv D/c (Single Moose) line for connectivity. The representative from Inox Wind Infrastructure Services Ltd informed that the connectivity is required from Sept 17.Keeping above in view, it was proposed to grant connectivity for 500 MW with the following system subjected to the availability of Tirunelveli PS and the wind developer shall provide adequate reactive compensation so that under all dispatch scenarios Power Factor of 0.98 shall be maintained.: Transmission System for Connectivity : Inox PS Tirunelveli PS 230 kv D/c (Single Moose) line Further, the applicant was advised to apply for LTA at the earliest. Members agreed for the same. 5.0 M/s Coastal Tamil Nadu Power Ltd CTU representative informed that the following application was pending since long: Sl. No Applicant Location Date of Application Start Date (As per application) Connectivity /LTA Sought (MW) 1. M/s Coastal Tamil Nadu Power Ltd. Kanchipuram, Tamil Nadu March (LTA & Connectivity) CTU representative informed that M/s Coastal Tamil Nadu Power Ltd has applied for LTA & connectivity of 4000 MW from Cheyyur UMPP. It was discussed in the 19 th Meeting of SR constituents regarding LTA & Connectivity wherein it was decided to close the long pending application due to uncertainty of the project schedule. However Coastal Tamil Nadu Power Ltd (CTNPL) vide letter dated
13 requested CTU to re-consider the decision, as CTNPL has informed that MoP, GoI has listed Cheyyur UMPP under Plug and Play and it was proposed to bid out in FY Subsequently, Coastal Tamil Nadu Power Ltd (CTNPL) vide letter dated 12 th July 2016 further informed that the UMPP is proposed to bid out in FY As bidding is yet to start and UMPP projects takes 48 months from the date of award, the project is expected beyond 13 th Plan. No representative of M/s CTNPL was present during the meeting. After detailed deliberations in light of the latest amendment in detailed procedure, it was agreed to close the application. The applicant may apply for new connectivity & LTA as and when the project progresses to the required milestones. Members agreed for the same. 6.0 Review of Generation Projects granted only Connectivity CTU representative informed that M/s Surana Power Limited was granted connectivity for 350 MW at Raichur (New) 765/400 kv substation (PGCIL) in 2011 through Surana Power Raichur (New) 400kV D/c line. The connectivity line was to be implemented by the applicant. Surana Power Limited about an year back in Mar 15 had informed that their project is expected by 2 nd quarter of No representative from Surana Power Limited was present to update the progress of their generation project & status of dedicated line. Further, the developer has not approached POWERGRID for implementation of bays at Raichur (New) end for termination of dedicated line. No progress has been made in implementation of the Connectivity system during past five years. Director (CEA) suggested for a seperate meeting with Surana Power Limited by CTU to discuss the progress of generation project. Members agreed for the same.
14 7.0 WR LTA applications for approval. 7.1 M/s Srijan Energy System Private Limited (SESPL) CTU representative informed that M/s Srijan Energy System Private Limited (SESPL) a wholly owned subsidiary of M/s Continuum Wind Energy (India) Pvt. Ltd. is developing a Wind Power Project around Bhuj, District Kutch, Gujarat. SESPL has applied LTA in ISTS for 300 MW (NR-150 MW, WR-90 MW & SR-60 MW) in which 60 MW power transfer is envisaged on target basis to SR from 31 st March, For transfer of power to SR, various inter-regional transmission links are already under implementation which would progressively enhance the ATC between NEW Grid & SR Grid. Accordingly, LTA for transfer of 60 MW to SR is proposed to be granted with progressive enhancement of ATC with progressive commissioning of following links: Wardha Nizamabad 765 kv D/c line along with Nizambad Dichpally 400 kv D/c Line (HTLS) Nizamabad Hyderabad (Maheshwaram) 765kV D/c line along with associated 400 kv Transmission System. The same was approved in 23 rd meeting of Western Region constituents for Connectivity / LTA applications held on Members agreed for the same. 7.2 Karnataka Power Corporation Limited (2x800 MW) CTU representative informed that KPCL, against their LTOA application of Dec, 2008 under the CERC Regulation 2004, was earlier granted LTOA vide intimation (revised) dated Aug, 2011 for 763 MW transfer of power from its 2x800 MW generation project in Janjgir-Champa, Chhattisgarh to Southern Region. Further, the BPTA was signed on As per the grant of LTOA, (i) target beneficiaries were Southern Region for entire 763 MW, (ii) the commissioning schedule for generation project was Sept, 15 and March, In the time frame of the grant of above LTOA, Southern region was
15 projected to be in huge surplus on account of large number of proposed generation project in SR having target beneficiaries in WR & NR. Therefore, the power transfer to SR from the project was planned through displacement. Accordingly, the transmission system associated with the grant of above LTOA included +800 kv 6000 MW HVDC bipole along with downstream network in NR. During the past five (5) years since grant of LTOA, generation project has not progressed. Further during this period there has been lot of development on the power scenario in SR, as per which the SR has turned into net importing region on account of delay of large number of generation. During the 11 th JCC meetings the generation developer has provided the status and stated that they are yet to receive some of the clearances because of which the work at site has not yet started. In the JCC meeting of WR held in Feb, 2016 KPCL has stated that they are yet to receive the MoEF clearance and the time frame of the project is uncertain. In view of the above, the transmission requirement for the LTOA earlier granted needs to be reviewed in view of the present scenario and the expected time frame of the generation project. Towards this the generation developer has stated that the time frame of the generation project shall be 48/54 months for Unit-I/II from the award which shall be after receiving MoEF clearance. The representative of KPCL informed that they are yet to receive the MoEF clearance and the time frame of the project is uncertain but it may be expected in the year of By this time frame the under implementation inter-regional links between NEW grid and SR grid shall be commissioned and shall be adequate for this transfer of power from generation project in Janjgir-Champa, Chhattisgarh to Karnataka. Hence it was proposed to delink the project from Champa- Kurukshetra. Further, action with regard to modification of LTA intimation of associating with above mentioned under construction transmission lines shall be undertaken after the commissioning schedule of generation projects attains certainity. Members agreed for the same
16 8.0 Reduction of LTA quantum of Neyveli Lignite Corporation Limited NNTPP(2x500 MW) (Replacement) generation in Tamil Nadu CTU representative informed that Long Term Access of 400 MW was granted to Neyveli Lignite Corporation Limited for its generation project in Tamil Nadu vide intimation no. C/CTU-Plg/LTA/S/2015/02-R1 dated and details of drawl of power is given below TANGEDCO MW (includes NLC share of 66 MW) AP Discoms MW Telangana Discoms MW Karnataka Discoms MW KSEB MW Puducheery 4.24 MW Unallocated MW All the beneficiaries have signed the LTA Agreement for the respective LTAs granted, wherein TANGEDCO has agreed and signed the LTA agreement for 53.07( ) MW only as against MW(includes NLC share of 66 MW) as the 66 MW is being availed by NLC. The matter has been taken up with NLC for signing of LTA agreement and NLC vide their letter dated informed that the 66 MW allocation from NNTPP(2x500 MW) is for NLC s internal loads of Mines & Township consumption and the same will be transmitted using NLC s own 220kV & 33kV transmission infrastructure & no ISTS network is being utilized for the same. In support to this NLC had quoted a CERC order dated in petition no. 89/2004 wherein it was stated that NLC is not a Long term customer utilizing the Regional Transmission System and should not be liable to share the transmission charges for the intra-regional assets within Southern Region and the regional transmission losses shall be shared by the Long term customers of Transmission System. Keeping above in view. It was proposed to reduce the quantum of LTA to 334 MW from 400 MW and same was agreed.
17 9.0 Other Issues (Additional Agenda) 9.1 Connectivity & Long term access for Tumkur (Pavagada) Ultra Mega Solar Power Park in Karnataka CTU representative informed that Karnataka Solar Power Development Corporation Ltd.(KSPDCL) has submitted connectivity & LTA application for transfer of power (2000 MW) from Tumkur (Pavagada) UMSPP. In the 39th standing committee meeting of southern region held on 28th-29th December 2015, transmission scheme was agreed in 2 phases for evacuation of power from proposed Tumkur (Pavagada) UMSPP (2000MW). However, implementation of all the elements in 2 phases may not be required for providing connectivity and therefore segregation of entire system into that for connectivity & LTA is necessary. Accordingly, following separate transmission system shall be considered for connectivity & LTA. Transmission System for Connectivity LILO of 400kV Gooty Tumkur (Vasantnarsapur) D/c at Tumkur (Pavagada) Pooling station 2x500 MVA, 400/220KV Pooling station at Tumkur(Pavagada). 220kV Bays(8 Nos) at Tumkur (Pavagada) PS for interconnection with solar project. Transmission System for LTA Phase-I (1000MW) Tumkur (Pavagada) Pooling station - Hiriyur 400 kv D/c(as part of Tumkur (Pavagada) Pooling station - Mysore line) LILO of 400kV Bellary Pool Tumkur (Vasantnarsapur) D/c (Quad)(both circuits)[kptcl line] at Tumkur (Pavagada) Pooling station Augmentation of 1x500 MVA, 400/220KV transformer at Tumkur(Pavagada) Pooling station 1x125MVAR bus reactor at 400/220KV Tumkur (Pavagada) Pooling station
18 Phase-II (1000MW) Hiriyur Mysore 400 kv D/c line $ Tumkur (Pavagada) Pooling station- Devanahally (KPTCL) 400kV D/c(Quad) Augmentation of 2x500 MVA, 400/220KV transformer at Tumkur(Pavagada) Pooling station 1x125MVAR bus reactor (2nd) at Tumkur (Pavagada) Pooling Station Third 400/220 kv, 1x500 MVA transformer at Tumkur (Vasantnarsapur) 1x80 MVAR switchable Line reactor at Mysore end of Hiriyur- Mysore D/c for each circuit KSPDCL vide letter dated informed that only 8 nos. of 220 kv line bays will be required instead of 16 nos. earlier as proposed. $ with the completion of this line, it would be connected with Tumkur(Pavagada) Pooling station - Hiriyur 400 kv D/c line to form Tumkur(Pavagada) -Mysore D/c line Members noted the same 9.2 Mytrah Energy India Ltd CTU representative informed that Mytrah Energy India Ltd. was granted connectivity for 300 MW and LTA for 75 MW for their wind generation at Tirunelveli through Mytrah-Tirunelveli PS 230 kv D/c line. Mytrah Energy India Ltd. vide letter dated informed that as the generation is planned in phases and that only 75 MW is planned in first phase, they would like to connect with the grid through 230 kv D/c line with one circuit strung initially. Hence they requested to provide one 230 kv Bay at Tirunelveli PS, initially. Members agreed for the same 9.3 LVRT Compliance CTU representative informed that all applicants of Wind/Solar Power should comply to the provision of LVRT (Low Voltage Ride Through) in accordance with CERC order on Petition No: 420/MP/2014. The applicants agreed for the same xx xx xx-----
19 Annexure-I List of participants of the 20 th Meeting of Southern Region regarding Connectivity and LTA applications of SR held on at POWERGRID, Gurgaon Sl. No. Name and Organization Designation Central Electricity Authority (CEA) 1. Rishika Sharan Director 2. Ajay Kumar Asst. Director Power Grid Corporation of India Limited (POWERGRID) 1. Seema Gupta COO (CTU-Planning & C.E) 2. Mukesh Khanna AGM (CTU-Planning) 3. Dilip Rozekar AGM (CTU-Planning) 4. Thiagarajan V DGM (CTU-Planning) 5. Kashish Bhambhani CM (Smart Grid) 6. Anil Kumar Meena CM (CTU-Planning) 7. Manish Pareta Sr. Engineer (CTU-Planning) 8. Tom George Engineer (CTU-Planning) 9. Venkatesh Gorli Engineer (CTU-Planning) 10. S.M Fahad Engineer (CTU-Planning) Power System Operation Corporation Limited (POSOCO) 1. N.Nallarasan DGM, NLDC 2. Muthu Kumar T Manager, SRLDC Kerala State Electricity Board Limited (KSEB Ltd.) 1. Sheela M Daniel Resident Engineer 2. Sreeja R.S Legal Assistant Connectivity/LTA Applicants 1. Srinivas C R Director Enerfra Projects (India) Pvt Ltd 2. Alok Gupta GM-PE Inox Wind Infrastructure Services Ltd 3. Manoj Dixit Head Power Inox Wind Infrastructure Services Ltd 4. S.N Sharma Resident Engineer Karnataka Power Corporation Ltd. 5. B.S Yadav Principal Adviser NSEFI 6. Dheeraj Jain Head Reg Affairs RegenPowertech Private Limited 7. V.K Agrawal Executive Director RegenPowertech Private Limited 8. Ravi A.S Sr. GM RegenPowertech Private Limited 9. Anil Asthana Advisor Samalkot Power Limited 10. Rakesh Rathore AVP Srijan Energy System Pvt. Ltd 11. Ujjwal Surana Sr.Mgr (Regulatory) Srijan Energy System Pvt. Ltd 12. Ravishankar S GM (Construction) Vestas Wind Technology India Pvt. Ltd
Agenda for the Meeting of Southern Region constituents regarding Connectivity/LTA Applications of IPPs in SR received during November & December, 2016
Agenda for the Meeting of Southern Region constituents regarding Connectivity/LTA Applications of IPPs in SR received during November & December, 2016 (To be discussed along with Agenda for Follow up Meeting
More informationDistribution List: Southern Region. 2. Chief Engineer (PSP&A II) Central Electricity Authority Sewa Bhawan, R.K.Puram, New Delhi
Distribution List: Southern Region. 1. Joint Secretary Ministry of New and Renewable Energy, Block 14, CGO Complex, Lodhi Road, New Delhi-110003 3. Director (Transmission) Transmission Corp. of Andhra
More informationCentral Electricity Authority PSPA-II Division Sewa Bhawan, R.K. Puram, New Delhi
Central Electricity Authority PSPA-II Division Sewa Bhawan, R.K. Puram, New Delhi 110066 No. 51/4(40 th )/PSPA-II/2016/ Date: 17-Nov-2016 Sub: 40th meeting of the Standing Committee on Power System Planning
More informationMember (PS) 2. Chief Engineer (PSPA-2) 3. Member Secretary 4. Chief Engineer (PSP&A - I) 5. The Member Secretary
To 1. Member (PS) Central Electricity Authority Sewa Bhawan, R.K.Puram, New Delhi-110 066. FAX : 011-26102045 2. Chief Engineer (PSPA-2) Central Electricity Authority Sewa Bhawan, R.K.Puram, New Delhi-110
More informationCentral Electricity Authority System Planning & Project Appraisal Division Sewa Bhawan, R.K. Puram, New Delhi
Central Electricity Authority System Planning & Project Appraisal Division Sewa Bhawan, R.K. Puram, New Delhi 110066. No. 51/4/SP&PA-2009/ 529-538 Date: June 05, 2009 To 1.The Member Secretary, Southern
More informationDistribution List: Southern Region. 2. Joint Secretary Ministry of New and Renewable Energy, Block 14, CGO Complex, Lodhi Road, New Delhi
Distribution List: Southern Region. 1. Member (PS) Central Electricity Authority Sewa Bhawan, R.K.Puram New Delhi-110 066 3. Chief Engineer (PSP&A II) Central Electricity Authority Sewa Bhawan, R.K.Puram,
More informationED (CMG) / ED (SR-I) / ED (SR-II) / COO (BDD) / ED (Commercial & RC)
Copy to: With a kind request to make it convenient to attend the above meeting. Shri S.K. RAY Mohapatra Chief Engineer (PSP&A-II) Central Electricity Authority Sewa Bhawan, R K Puram New Delhi 110 066.
More informationDistribution List: 11. Director Betam Wind Energy Private Limited 15 th Floor, Tower B, Vatika Tower, Golf Course Road, Sector-54, Gurgaon
Distribution List: 1. Managing Director Andhra Pradesh Solar Power Corporation Pvt Ltd Room No: 218, 2 nd Floor, Vidyut Soudha, Khairatabad, Hyderabad- 500 082 Tel : 040-23499401 / +91-9848543434 Email:
More informationCopy to : ED (CMG) / ED (SR-I) / ED (SR-II) / COO (BDD) / ED (Commercial & RC)
Copy to : ED (CMG) / ED (SR-I) / ED (SR-II) / COO (BDD) / ED (Commercial & RC) Distribution List - SR:. GM, (Commercial) NTPC Limited (Kudgi TPS) NTPC Bhavan, Core-7, Scope Complex 7, Institutional Area,
More informationDistribution List: Constituents of Southern region.
Distribution List: Constituents of Southern region. 1. Member (PS) Central Electricity Authority Sewa Bhawan, R.K.Puram, New Delhi-110 066. 3. Member Secretary Southern Regional Power Committee 29, Race
More informationDistribution List: 1. Member (PS) Central Electricity Authority Sewa Bhawan, R.K.Puram, New Delhi Chief Engineer (PSP&A II)
Distribution List: 1. Member (PS) Central Electricity Authority Sewa Bhawan, R.K.Puram, New Delhi-110 066. 3. Chief Engineer (PSP&A - I) Central Electricity Authority Sewa Bhawan, R.K.Puram New Delhi-110
More information2. Director (W &P) UPPTCL, Shakti Bhawan Extn,3rd floor, 14, Ashok Marg, Lucknow (Fax: )
1. Member, Secretary, NRPC, 18-A Shajeed Jeet Singh Sansanwal Marg, Katwaria Sarai, New Delhi - 110016 (Fax-011-26865206) 4. Director (Technical), Punjab State Transmission Corperation Ltd. (PSTCL) Head
More informationAdditional Agenda Note for 30 th Meeting of Standing Committee on Power System Planning in Western Region
Additional Agenda Note for 30 th Meeting of Standing Committee on Power System Planning in Western Region 1.0 Transmission System for IPPs located in Orissa 1.1 The transmission system for evacuating power
More informationCopy: with a request to kindly make it convenient to attend the above meeting
Copy: with a request to kindly make it convenient to attend the above meeting 1. Member (PS) Central Electricity Authority Sewa Bhawan, R.K.Puram, New Delhi-110 066. 2. Chief Executive Officer Power System
More informationNational Load Despatch Centre Power System Operation Corporation
Module on Procedure for Data Collection National Load Despatch Centre Power System Operation Corporation Background Algorithms/ Processes AC Load flow and transmission losses Slack bus determination- Average
More informationPower Grid Corporation of India Limited. Analysts Presentation February 9, 2011
Power Grid Corporation of India Limited Analysts Presentation February 9, 2011 1 Listed Company with public holding of 30.58% and balance by Government of India Central Transmission Utility of the country
More informationTamil Nadu: Current Power scenario and projects in pipeline
Tamil Nadu: Current Power scenario and projects in pipeline 1. Tamil Nadu per capita consumption is over 1000 Units, which is as against 11 th plan national target of 1000 units. Presently, the national
More informationqlq:~ ~ CbI"lq)~!l1OI 3ii4i ~;UI fclfcrds ('liffif ~ '5T ~) POWER GRiD CORPORATION OF INDIA LIMITED (A Government of India Enterprise)
qlq:~ ~ CbI"lq)~!l1OI 3ii4i ~;UI fclfcrds ('liffif ~ '5T ~) POWER GRiD CORPORATION OF INDIA LIMITED (A Government of India Enterprise) ~ 'l>mr>m : "41tU fii'1'1', '
More informationSOLAR POWER DEVELOPMENT VGF OPTION UNDER JNNSM. Dr. Ashvini Kumar Director (Solar) Solar Energy Corporation of India
1 SOLAR POWER DEVELOPMENT VGF OPTION UNDER JNNSM Dr. Ashvini Kumar Director (Solar) Solar Energy Corporation of India 2 SOLAR ENERGY CORPORATION OF INDIA A Government of India Enterprise under the administrative
More informationExcellence Enhancement Centre (EEC) for Indian Power Sector was : Conceptualised as part of bilateral cooperation between Govt. of India and Govt.
1 Excellence Enhancement Centre (EEC) for Indian Power Sector was : Conceptualised as part of bilateral cooperation between Govt. of India and Govt. of Federal Republic of Germany. Registered as a non-profit
More informationSOUTHERN REGIONAL POWER COMMITTEE BENGALURU. Record Notes of the Meeting to discuss disruption of power supply affecting BMRCL services
SOUTHERN REGIONAL POWER COMMITTEE BENGALURU Record Notes of the Meeting to discuss disruption of power supply affecting BMRCL services A Meeting to discuss disruption of power supply affecting BMRCL services
More informationF.No.3/23/2011-Trans Government of India Ministry of Power Shram Shakti Shawan, Rafi Marg
F.No.3/23/2011-Trans Government of India Ministry of Power Shram Shakti Shawan, Rafi Marg New Delhi, Dated, io" October, 2014 To 1. Chief Secretary(Power), Government of Arunachal Pradesh, Itanagar. 2.
More informationSUPPLEMENTARY AGENDA POINTS FOR 496-OCC MEETING
SUPPLEMENTARY AGENDA POINTS FOR 496-OCC MEETING SA-1. GUJARAT ADDITIONAL AGENDA ITEMS: Chief Engineer, SLDC Gujarat vide mail dated 09.06.17 requested to discuss the following additional points in the
More informationSOUTHERN REGIONAL POWER COMMITTEE BENGALURU
SOUTHERN REGIONAL POWER COMMITTEE BENGALURU Additional Agenda for the 80 th Meeting of Protection Coordination Sub-Committee of SRPC to be held on 20-21 December, 2018 1. Grid Occurrences Additional Grid
More informationAdvanced Ultra Power Transmission Consultancy
2100 Advanced Ultra Power Transmission Consultancy AUPTC the Complete Solutions to Power Infrastructure, Electrical, Electronics, Automation, HVAC Advanced Ultra Power Transmission Consultancy About AUPTC
More informationGUIDE TO REGISTRATION AS UTILITY AND APPLICANT ON SHORT TERM OPEN ACCESS SOFTWARE
GUIDE TO REGISTRATION AS UTILITY AND APPLICANT ON SHORT TERM OPEN ACCESS SOFTWARE 1 The Short Term Open Access (STOA) in Inter State Transmission System (ISTS) was commenced in the year 2004 through a
More informationJharkhand Orrisa West Bengal MP Maharashtra Chhattisgarh UMPP & NTPC projects
Proposed transmission system in WR for various generation projects in Jharkhand, Orissa, West Bengal, Chhattisgarh, M.P. and Maharashtra and other NTPC projects System studies have been carried out to
More informationNetwork Development in Mumbai City Area The Tata Power Company Ltd. (Distribution Business)
Network Development in Mumbai City Area The Tata Power Company Ltd. (Distribution Business) TABLE OF CONTENTS 1 INTRODUCTION... 5 1.1 Background... 5 1.2 EXISTING NETWORK OF TATA POWER IN MUMBAI CITY AREA...
More informationReliance Infrastructure Limited
Reliance Infrastructure Limited Reg. : H Block, 1 st Floor, Dhirubhai Ambani Knowledge City, Navi Mumbai 400 710 Website: www.rinfra.com PUBLIC NOTICE Objections / suggestions on Reliance Infrastructure
More informationIndian Power Grid Developments
Indian Power Grid Developments Rathin Basu Country President, Alstom Grid, March 25 th 2015 Evolution of Voltage level of Indian Grid kv Anticipated the evolution & Timely Investment in Indian Facilities
More informationIMS INTERFACE MARKET PROCEDURE NETWORK OPERATORS AND AEMO
IMS INTERFACE MARKET PROCEDURE NETWORK OPERATORS AND AEMO PREPARED BY: System Management (WA) DOCUMENT REF: SO_OP_WA_3805 VERSION: 1.0 EFFECTIVE DATE: 13/10/2017 STATUS: FINAL Approved for distribution
More informationMinutes of the Special Meeting on URTDSM / SCADA / Communication held on
Minutes of the Special Meeting on URTDSM / SCADA / Communication held on 13.03.2018 1. Introduction A Special Meeting on URTDSM / SCADA / Communication was held on 13.03.2018 at SR-II, PGCIL, Bengaluru.
More informationDistribution List: Constituents of Northern Region.
Distribution List: Constituents of Northern Region. 1. Member (PS) Central Electricity Authority Sewa Bhawan, R.K.Puram New Delhi-110 066 3. Chief Engineer (PSP&A-I) Central Electricity Authority Sewa
More informationIMS INTERFACE MARKET PROCEDURE NETWORK OPERATORS AND AEMO
IMS INTERFACE MARKET PROCEDURE NETWORK OPERATORS AND AEMO PREPARED BY: System Management (WA) DOCUMENT REF: SO_OP_WA_3805 VERSION: 1.0 EFFECTIVE DATE: 13/10/2017 STATUS: DRAFT FOR CONSULTATION Approved
More informationMFC Power General Partner Ltd.,
Decision 21950-D01-2016 Preferential Sharing of Records Between, MFC Power Limited Partnership, URICA Energy Real Time Ltd., and URICA Asset Optimization Ltd. October 12, 2016 Alberta Utilities Commission
More informationJanuary 22, The Honorable Kimberly D. Bose Secretary Federal Energy Regulatory Commission 888 First Street, N.E. Washington, D.C.
California Independent System Operator Corporation January 22, 2013 The Honorable Kimberly D. Bose Secretary Federal Energy Regulatory Commission 888 First Street, N.E. Washington, D.C. 20426 Re: California
More informationFile No. SR-NASD-00-70
November 29, 2000 Ms. Katherine A. England Assistant Director Division of Market Regulation Securities and Exchange Commission 450 Fifth Street, N.W. Washington, D.C. 20549-1001 Re: File No. SR-NASD-00-70
More informationMemorandum. This memorandum requires Board action. EXECUTIVE SUMMARY
California Independent System Operator Corporation Memorandum To: ISO Board of Governors From: Keith Casey, Vice President, Market & Infrastructure Development Date: May 21, 2014 Re: Decision on interconnection
More information2. Director (Transmission) Ministry of Power, Shram Shakti Bhawan, Rafi Marg New Delhi FAX No
1. Member (PS) Central Electricity Authority Sewa Bhawan, R.K.Puram New Delhi-110 066 3. The Member Secretary Western Regional Power Committee MIDC area, Marol, Andheri East, Mumbai 400 093 5. Chief Engineer(SP
More informationUSER MANUAL FOR SHORT-TERM OPEN-ACCESS APPLICATION
USER MANUAL FOR SHORT-TERM OPEN-ACCESS APPLICATION MANAGEMENT SOFTWARE Maharashtra State Load Dispatch Centre (Maharashtra State Electricity Transmission Co. Ltd.) Developed & Prepared by India s Largest
More informationDecision D ATCO Electric Ltd. Crystal Lake 722S Substation Telecommunications Tower Replacement
Decision 21617-D01-2016 Crystal Lake 722S Substation October 5, 2016 Alberta Utilities Commission Decision 21617-D01-2016 Crystal Lake 722S Substation Proceeding 21617 Application 21617-A001 October 5,
More informationDIVYASREE TECHNOPARK SEZ 26 th APPROVAL COMMITTEE MEETING. (1/2016 series) DATE: 14/03/2016. TIME: a.m.
DIVYASREE TECHNOPARK SEZ 26 th APPROVAL COMMITTEE MEETING (1/2016 series) DATE: 14/03/2016 TIME: 11.30 a.m. Agenda for the 25 the Meeting (1/2016 series) of the Approval Committee of Divyasree Technopark
More informationMinutes of 4 th Meeting of the National Reliability Council for Electricity (NRCE) held on at NRPC, New Delhi
GOVERNMENT OF INDI1A MINISTRY OF POWER CENTRAL ELECTRICITY AUTHORITY SEWA BHAWAN, R.K.PURAM NEW DELHI-110066 Website: www.cea.nic.in (आई.एस.ओ. 9001:2008) No. CEA/ NRC/RA 2014 Dated 3.11.2014 To As per
More informationInviting Expression of Interest for. Leasing of Dark fiber on DMRC Network
Inviting Expression of Interest for Leasing of Dark fiber on DMRC Network Delhi Rail Corporation is engaged in the business of constructing, operating & maintaining Mass Rapid Transport Network. DMRC is
More informationMinutes for 8 th Connectivity & Long Term Access Meeting with Northern Region Constituents held on 20/01/2016 at NRPC Office, Delhi.
Minutes for 8 th Connectivity & Long Term Access Meeting with Northern Region Constituents held on 20/01/2016 at NRPC Office, Delhi. A. CTU welcomed the participants and informed that Minutes of the 7
More informationMemorandum. This memorandum requires Committee action.
California Independent System Operator Corporation Memorandum To: ISO Operations Committee From: Dariush Shirmohammadi, Director of Regional Transmission - South Armando Perez, VP, Planning & Infrastructure
More informationJuly 30, Q2 Quarterly Report on Progress in Processing Interconnection Requests; Docket No. ER
California Independent System Operator Corporation The Honorable Kimberly D. Bose Secretary Federal Energy Regulatory Commission 888 First Street, N.E. Washington, D.C. 20426 July 30, 2010 Re: Q2 Quarterly
More informationORISSA ELECTRICITY REGULATORY COMMISSION BIDYUT NIYAMAK BHAWAN UNIT VIII, BHUBANESWAR **********
ORISSA ELECTRICITY REGULATORY COMMISSION BIDYUT NIYAMAK BHAWAN UNIT VIII, BHUBANESWAR 751012 ********** Present : Shri B K Das, Chairperson Shri K C Badu, Member Shri B K Mishra, Member Case No. 101/2009
More informationNo. 07/03/CEA/PFAM/(Distribution Plan)/2016/ Dated:
Government of India Central Electricity Authority PFA Monitoring Division Sewa Bhawan, R K Puram, New Delhi-110066 cepfacea@rediffmail.com, ce.pfam.cea@gov.in Telefax :011-2671 5396 Ph:011-2673 2607 (आई
More informationTAMIL NADU GENERATION AND DISTRIBUTION CORPORATION LTD. ADMINISTRATIVE BRANCH. Letter No /G.39/G.393/2018-1, dated
REMINDER-III: TAMIL NADU GENERATION AND DISTRIBUTION CORPORATION LTD. ADMINISTRATIVE BRANCH From Er. A. ASHOK KUMAR, B.E., Chief Engineer/ Personnel, 144, Anna Salai, Chennai 600 002. To The Superintending
More informationWECC Criterion MOD-(11 and 13)-WECC-CRT-1.1
WECC Criterion MOD-(11 and 13)-WECC-CRT-1.1 A. Introduction 1. Title: Steady State and Dynamic Data Requirements 2. Number: MOD-(11 and 13)-WECC-CRT-1.1 3. Purpose: To establish the consistent data requirements
More informationDistribution List R.K.M. Powergen Pvt. Ltd. Jindal Power Ltd. Athena Chhattisgarh Power Pvt Ltd SKS Power Generation (Chhattisgarh) Ltd.
Distribution List 1. Sh. J Mohan GM (Planning) R.K.M. Powergen Pvt. Ltd. 14, Dr. Giriappa Road, T. Nagar, Chennai - 600 017 E-mail: j.mohan@rkmpowergen.in Mob: 09176792020 3. Sh. R. Srinivasan Vice President
More informationB-1-1. Janet L. Fraser Director, Regulatory Affairs Phone: Fax:
B-- Janet L. Fraser Director, Regulatory Affairs Phone: 0-- Fax: 0-- E-mail: janet.fraser@bctc.com October 00 Ms. Erica Hamilton Commission Secretary British Columbia Utilities Commission 00 Howe Street,
More informationENMAX Power Corporation
Decision 22769-D01-2017 Transmission Lines 138-1.80L and 138-1.81L September 15, 2017 Alberta Utilities Commission Decision 22769-D01-2017 Transmission Lines 138-1.80L and 138-1.81L Proceeding 22769 Application
More informationCopy for Kind information : ED (Commercial & RC)/ED (NR-I)/COO (BDD)/ED (Engg-TL & SS)
Copy for Kind information : ED (Commercial & RC)/ED (NR-I)/COO (BDD)/ED (Engg-TL & SS) Distribution List: Northern Region. Joint Secretory MNRE Block 14, CGO Complex, Lodhi Road, New Delhi - 110003 Member
More informationAgenda for Connectivity/Long term Access to Generation projects in Northern Region
Agenda for Connectivity/Long term Access to Generation projects in Northern Region POWERGRID has received Connectivity and Long term Access applications for new generation projects in NR. In addition,
More informationSolution Renewables. tgood.com
Solution Renewables tgood.com TGOOD Introduction TGOOD is the global leader in prefabricated electric power distribution solutions. It is the company that first comes to mind when cost-effective electric
More informationED (Commercial) / ED (CMG) / ED (ER-I) / ED (ER-II) / COO (BDD)
Copy to: With a kind request to make it convenient to attend the above meeting. Shri Pardeep Jindal Chief Engineer (PSP&A-II) Central Electricity Authority, Sewa Bhawan, New Delhi 110 066. ED (Commercial)
More informationAddress and Tel.No. of the Director, Legal Metrology GOI
Address and Tel.No. of the Director, Legal Metrology GOI 1) Mr. B.N. Dixit, Director. Deptt. of Consumer Affairs, Room No.461-A, Krishi Bhawan, New Delhi - 110 001. Tel. No. 23389489 Fax No. 23385322 Controllers
More information~m"ifir ~ ~ ~1~ItI~UI ~ ~ ~ 4~~lut"11 ~iif>"f ~ ~~. ~ltt9l~i~~'1! ~ W "ip".~.: 26/10/2009-~. m. ti. ~/, l( b -(59 ~:
~m"ifir ~ ~ ~1~ItI~UI ~ ~ ~ 4~~lut"11 ~iif>"f ~ ~~. ~ltt9l~i~~'1! ~ W 110066 "ip".~.: 26/10/2009-~. m. ti. ~/, l( b -(59 ~: 09.08.2010 1 ~(~~), 8 ~~~~,~~~), ~ ~ III~qI~UI, ; ~ t!jqx qll~yi~~i-1 3frffI
More informationCANARA BANK NRI CELL, CIRCLE OFFICE 1ST FLOOR, RED CROSS BHAVAN SACHIVALAYA MARG BHUBANESWAR : ODISHA, INDIA E MAIL ID:
CONTACT DETAILS For any information/clarification/grievance on matters connected with NRIs, please contact our BRANCHES spread across the country: NRIs may also contact the following NRI Cells/Offices.
More informationFrom: Laura Manz, Vice President of Market & Infrastructure Development
California Independent System Operator Corporation Memorandum To: ISO Board of Governors From: Laura Manz, Vice President of Market & Infrastructure Development Date: May 8, 2009 Re: Decision for Conditional
More informationHandout on. Mobile Number Portability. For Sales Channels
Handout on Mobile Number Portability For Sales Channels Contents 1. Introduction of MNP 2. Areas where MNP is permitted 3. Some terminologies related to MNP 4. Why a customer should join BSNL? 5. Porting
More informationInviting Expression of Interest for. Leasing of Dark fiber on DMRC Network
Inviting Expression of Interest for Leasing of Dark fiber on DMRC Network Delhi Metro Rail Corporation is engaged in the business of constructing, operating & maintaining Mass Rapid Transport Network.
More informationSub: Review of Performance of GRIDCO for the FY held on
ODISHA ELECTRICITY REGULATORY COMMISSION BIDYUT NIYAMAK BHAVAN, PLOT NO. 4, CHUNOKOLI, SHAILASHREE VIHAR, BHUBANESWAR-751021 TEL. No. 2721048, 2721049, FAX : 2721053/2721057 E-mail: orierc@gmail.com, Website:
More informationPOWER TRANSMISSION IN INDIA 2018
Now Available POWER TRANSMISSION IN INDIA 2018 Segment Trends and Developments; Outlook and Projections Report (PDF) Data-set (Excel) India Infrastructure Research Power Transmission in India 2018 Table
More informationCAPACITY BUILDING OF DISCOMS UNDER DEMAND SIDE MANAGEMENT SCHEME XII PLAN INITIATED BY
CAPACITY BUILDING OF DISCOMS UNDER DEMAND SIDE MANAGEMENT SCHEME XII PLAN INITIATED BY BUREAU OF ENERGY EFFICIENCY MINISTRY OF POWER 24/11/2014 2 Rationale.. Demand Side Management (DSM) Cost effective
More informationbcuc British Columbia Utilities Commission
January 26, 2018 bcuc British Columbia Utilities Commission Patrick Wruck Commission Secretary Commission.Secretary@bcuc.com bcuc.com Suite 410, 900 Howe Street Vancouver, BC Canada V6Z 2N3 P: 604.660.4700
More informationCHAPTER 4 INCREASE IN CRITICAL CLEARING TIME USING SVC AND STATCOM IN TNEB
80 CHAPTER 4 INCREASE IN CRITICAL CLEARING TIME USING SVC AND STATCOM IN TNEB 4.1 INTRODUCTION The preliminary study conducted to evaluate the potential due to the application of SVC and STATCOM on the
More informationStandard Wind DPR: Essential Contents
Standard Wind DPR: Essential Contents [Note: The below provided sections and the sub points indicated in the table have to be mandatorily provided by the Wind Project Developers while submitting the Detailed
More informationTURKISH STANDARDS INSTITUTION
TURKISH STANDARDS INSTITUTION NEW GLOBAL OLD APPROACH REGULATIONS CONFORMITY ASSESSMENT PROCEDURES AND PRINCIPLES Board Decision : 29.04.2014 Date 50.-236 Validity date : 05.05.2014 CHAPTER ONE Objective,
More informationHighlights of Telecom Subscription Data as on 31 st October, 2018
For immediate release (Press Release No. 01/2019) Information Note to the Press TELECOM REGULATORY AUTHORITY OF INDIA New Delhi, 2 nd January, 2019 (www.trai.gov.in) 20 Glorious Years (1997-2017) Highlights
More informationHighlights of Telecom Subscription Data as on 28 th February, 2018
For immediate release (Press Release No.48/2018) Information Note to the Press TELECOM REGULATORY AUTHORITY OF INDIA New Delhi, 24 th April, 2018 (www.trai.gov.in) 20 Glorious Years (1997-2017) Highlights
More informationApplications Granted Medium Term Open Access (MTOA) by POWERGRID
1 B.N.Mehta, Superintending Engineer, 32 1-Jun-2011 31-Mar-2012 UT-DNH UT DNH 2 M.R.Ingle, Executive Engineer, UTDD 22 1-Jun-2011 31-Mar-2012 UT-DD 3 SAIL - VISP NSPCL, Bhilai, 10.92 1-Nov-2011 31-May-2014
More informationChapter 5A Embedded Generation Information Pack United Energy s guide to the Embedded Generation connection process for of Chapter 5A
Chapter 5A Embedded Generation Information Pack United Energy s guide to the Embedded Generation connection process for of Chapter 5A Public Table of contents 1 Connection Framework... 3 2 Connection Types...
More informationMarch 15, 2011 VIA ELECTRONIC FILING
California Independent System Operator Corporation VIA ELECTRONIC FILING The Honorable Kimberly D. Bose Secretary Federal Energy Regulatory Commission 888 First Street, NE Washington, D.C. 20246 Re: California
More informationGOVERNMENT OF INDIA MINISTRY OF COMMUNICATIONS DEPARTMENT OF TELECOMMUNICATIONS
GOVERNMENT OF INDIA MINISTRY OF COMMUNICATIONS DEPARTMENT OF TELECOMMUNICATIONS LOK SABHA UNSTARRED QUESTION NO.2496 TO BE ANSWERED ON 26 TH DECEMBER, 2018 2496. SHRI KAUSHALENDRA KUMAR: SHRIMATI NEELAM
More informationup of SPMU in States/UTs under NeGP A
1/12/2015 Guidelines for Setting up of SPMU in States/UTs under NeGP A Department of Agriculture & Cooperation (DAC), Ministry of Agriculture, New Delhi Contents 1. Introduction... 2 2. Scope of Work of
More informationENMAX Generation Portfolio Inc.
Decision 22192-D01-2017 ENMAX Generation Portfolio Inc. September 5, 2017 Alberta Utilities Commission Decision 22192-D01-2017 ENMAX Generation Portfolio Inc. Proceeding 22192 Application 22192-A002 September
More informationWritten Testimony of Rick Gonzales Senior Vice President and Chief Operating Officer New York Independent System Operator
Assembly Standing Committee on Energy Kevin A. Cahill, Chairman Assembly Standing Committee on Corporations, Authorities and Commissions James F. Brennan, Chairman Assembly Standing Committee on Cities
More informationControllers Address, Phone No., Fax No. &
Controllers Address, Phone No., Fax No. & Email S.No. Address, Phone No., Fax No., E-mail 1. Controller, Legal Metrology Department, Door.No: 48-8-12 & 12A, Boddupativari Street, Near ESI Hospital, Gunadala,
More informationOrder No Compliance Filing Related to Interconnection Issues Proposed Transmission Interconnection Process
Order No. 1000 Compliance Filing Related to Interconnection Issues Proposed Transmission Interconnection Process Thinh Nguyen Manager, Interconnection Projects New York Independent System Operator Joint
More informationNetwork Configuration Document Selection for New Substations Framework
Network Configuration Document Selection for New Substations Current version: 20/06/2018 EXTERNAL USE Page 1 of 14 Table of contents 1. Introduction... 3 1.1 Purpose... 3 1.2 Scope... 3 1.3 References...
More informationList of members of TCC
MAILING LIST FOR AGENDA OF 18TH WRPC List of members of WRPC List of members of TCC 1 Chairman, CSPTCL & Chairman, WRPC 1 Managing Director, CSPTCL & Chairman, TCC 2 Member (GO&D), CEA, New Delhi 2 Chief
More informationEnergy Efficiency Improvements in Commercial Buildings (EECB)
UNDP GEF BEE Project: Energy Efficiency Improvements in Commercial Buildings (EECB) November 2016, New Delhi Dr. S N Srinivas Program Analyst, UNDP India sn.srinivas@undp.org Energy Efficiency Improvements
More informationRfP No. APSFL/CCTVPMA/231/2016, Dated:
S.No 1 2 3 RfP No. APSFL/CCTVPMA/231/2016, Dated: 30.05.2018 RfP for Selection of Project Monitoring Agency (PMA) for implementation of cloud based IP CCTV Surveillance System in AP Corrigendum 2 Dated:
More informationSTCP22-1 Issue 003 Production of Models for GB System Planning
STCP22-1 Issue 003 Production of Models for GB System Planning STC Procedure Document Authorisation Company Name of Party Representative Signature Date National Grid Electricity Transmission plc SP Transmission
More informationNOTICE OF APPLICATION AND WRITTEN HEARING
Ontario Energy Board Commission de l énergie de l Ontario EB-2012-0305 NOTICE OF APPLICATION AND WRITTEN HEARING Application by Hydro One Networks Inc. and Kitchener-Wilmot Hydro Inc. for Licence Amendments
More informationFORUM LOAD DESPATCHERS (FOLD)
CHARTER OF FORUM OF LOAD DESPATCHERS (FOLD) FOLD Secretariat NLDC,B-9 Qutab Institutional Area, New Delhi http://www.forumofld.in http://www.forumofloaddespatchers.in Table of Contents 1. Background...3
More informationADB s Energy Program in Myanmar
ADB s Energy Program in Myanmar March 2014 Chong Chi Nai Director, Energy Division Southeast Asia Regional Department 1 Current Sector Context Low electrification ratio Need to develop cost effective way
More informationODISHA ELECTRICITY REGULATORY COMMISSION BIDYUT NIYAMAK BHAWAN UNIT-VIII, BHUBANESWAR ************
ODISHA ELECTRICITY REGULATORY COMMISSION BIDYUT NIYAMAK BHAWAN UNIT-VIII, BHUBANESWAR - 751 012 ************ Present: Shri S. P. Nanda Chairperson Shri B. K. Misra, Member Shri S. P. Swain, Member Case
More information4.1.1 Generator Owner Transmission Owner that owns synchronous condenser(s)
A. Introduction 1. Title: Verification and Data Reporting of Generator Real and Reactive Power Capability and Synchronous Condenser Reactive Power Capability 2. Number: MOD-025-2 3. Purpose: To ensure
More informationGreen Power Market Development Group - Scaling up Renewable Energy Sector in India 04 th December An initiative supported by
Green Power Market Development Group - Scaling up Renewable Energy Sector in India 04 th December 2018 An initiative supported by Green Power Market Development Group Objective: Scaling up Renewable energy
More informationFeasibility Study on Load Flow and Short Circuit Project
Feasibility Study on Load Flow and Short Circuit Project 101813-01 Prepared by: Transmission Planning Department Cleco Corporation, Inc. 2180 St. Landry Hwy P.O. Box 70 St. Landry, LA 71367 Final November
More informationThe Narragansett Electric Company. d/b/a National Grid (Rhode Island Reliability Project) RIPUC Dkt. No Testimony of. Todd G. Kopoyan, P.E.
d/b/a National Grid (Rhode Island Reliability Project) RIPUC Dkt. No. 0 Testimony of Todd G. Kopoyan, P.E. February 0, 00 0 0 INTRODUCTION Q. Please state your name and business address. A. My name is
More informationNEWFOUNDLAND AND LABRADOR BOARD OF COMMISSIONERS OF PUBLIC UTILITIES AN ORDER OF THE BOARD NO. P.U. 13(2015)
NEWFOUNDLAND AND LABRADOR BOARD OF COMMISSIONERS OF PUBLIC UTILITIES AN ORDER OF THE BOARD NO. P.U. 13(2015) 1 IN THE MATTER OF the Electrical Power 2 Control Act, 1994, SNL 1994, Chapter E-5.1 (the 3
More informationCALIFORNIA INDEPENDENT SYSTEM OPERATOR CORPORATION FERC ELECTRIC TARIFF ORIGINAL VOLUME NO. III Original Sheet No. 977 METERING PROTOCOL
ORIGINAL VOLUME NO. III Original Sheet No. 977 METERING PROTOCOL ORIGINAL VOLUME NO. III Original Sheet No. 978 METERING PROTOCOL Table of Contents MP 1 OBJECTIVES, DEFINITIONS AND SCOPE MP 1.1 Objective
More informationATCO Electric Ltd. Dawes Substation and Telecommunications Tower Project Facility Application
Decision 2014-039 Dawes Substation and Telecommunications Tower Project Facility Application February 19, 2014 The Alberta Utilities Commission Decision 2014-039: Dawes Substation and Telecommunications
More informationNext Generation 911; Text-to-911; Next Generation 911 Applications. SUMMARY: In this document, the Federal Communications Commission (Commission)
This document is scheduled to be published in the Federal Register on 10/29/2013 and available online at http://federalregister.gov/a/2013-25274, and on FDsys.gov 6712-01 FEDERAL COMMUNICATIONS COMMISSION
More informationQ3 FY Press & Analysts Meet Mumbai January 28, 2016
Q3 FY 2015-16 Press & Analysts Meet Mumbai January 28, 2016 Disclaimer By attending the meeting where this presentation is made, or by reading the presentation slides, you agree to be bound by the following
More information