CCNA 1: Networking Basics v3.0 Cisco Networking Academy Program

Size: px
Start display at page:

Download "CCNA 1: Networking Basics v3.0 Cisco Networking Academy Program"

Transcription

1 F.A.R.B Case Study F.A.R.B Software Development, LTD.: Network Design and Implementation CCNA 1: Networking Basics v3.0 Cisco Networking Academy Program

2 Overview Students completing this case study should be able to: Gather information for the pre-installation process and lay plans for the installation process. Create documentation as would be required for creating a real network. Comply with TIA, EIA, and electrical standards These objectives are spelled out within this case study in a letter from Cheryl Farb, President, FARB Software Development LTD., which for this case study is serving as the client company. General Design Process Framework Network design is best done by following a framework. To determine where the wires go requires knowledge of the structure to be networks. You will need to know where the users are, and what their applications are, in order to begin to sketch out a viable network. A layer one LAN logical and physical topology must be developed. This development includes the type of cable and the physical (wiring) topology that are selected, and the physical placement of infrastructure connection points on the network. A Layer 2 segmentation plan must be overlaid on the previously created Layer 1 topology. This layer plan includes devices added to the topology to improve its efficiency and functionality. Examples of these devices might be switches and bridges. This layer also includes the use of technologies such as micro-segmentation, VLANS, and STP, to add efficiency and reliability. A Layer 3 hierarchical plan is then overlaid on both of the previous two layers. This plan includes adding Layer 3 devices that will provide Intranetwork and Internetwork functionality to the network, as well as creating a network address plan. Layer 3 is where routing and firewalls are implemented imposing a logical structure on the network. They can also be used for segmentation of both collision and broadcast domains. An extension of the Layer 3 plan might be considered a Layer 4 plan. This plan could be laid over the first three, moves strictly to software, and controls access and availability of the network. It involves access lists and firewall configuration. While a complete network design will keep moving up the OSI model, it is beyond the focus of this project. This design will focus on Ethernet, IP, Layer 1, Layer 2, and Layer 3, which is the focus of this curriculum. The design process logically flows up the layers of the OSI model. 1-2 CCNA 1: Networking Basics v3.0 F.A.R.B Case Study Copyright 2003, Cisco Systems, Inc.

3 The most important and many times the most neglected part of network design and operation is the documentation. The main focus of this project is the documentation of the network design. Documentation for this project should include wiring maps, addressing schemes, any brainstormed ideas, problem-solving matrices, and any other notes made while making these determinations. Pre-design process Before a network can be designed, the data needed to design the network must be gathered. In order for a network to be effective and serve the needs of its users, it should be gathered according to a systematic series of preplanned steps. These steps provide a guide to completely discover the data needed to create the network. The first step in the process is to gather information about the organization. This information should include: Organization history and current status Projected growth Operating policies and management procedures Building diagrams (blueprints) Existing network diagrams and documentation Office systems and procedures Viewpoints of the people who will be using the LAN In the Case Study Material Packet, you will find communications from the president outlining of F.A.R.B Software Development, LTD. In this letter, Farb indicates her specific requirements for this project. The second step is to make a detailed analysis and assessment of the current and projected requirements gathered in the first step. This step will identify and define issues or problems that need to be addressed (e.g. a remote room in the building may not have network access). It will also provide information about future network expansion needs, access, and security. The third step is to identify the resources and constraints of the organization. Organization resources that can affect the implementation of a new LAN system fall into the categories of hardware, software, and human resources. If this were a network expansion or upgrade, existing computer hardware and software must 1-3 CCNA 1: Networking Basics v3.0 F.A.R.B Case Study Copyright 2003, Cisco Systems, Inc.

4 be documented. Identification and the definition of those projected needs must also be done. The answers to some of these questions will also help determine how much training will be required, and how many people will be needed to support the LAN. The questions asked should include: What are the financial resources of the organization? How are these resources currently linked and shared? How many people will be using the network? What are the computer skill levels of the network users? What are the attitudes toward computers and computer applications? Following these steps, documenting the information in the framework of a formal report will help estimate costs and develop a budget for the implementation of a LAN. Design methodology and deliverables With the material that has been presented to this point, a strong foundation and understanding should have been developed for the concepts of a layered communications model. Using the OSI model as the framework, an understanding of the functions and devices that support operations at those layers should also have been gained. To perform this case study, material related to the physical design and installation of a network must be learned. As was presented in previous material, there are rules and standards that govern how a network is designed and built. These rules and standards must be learned before the actual case study can be performed. Students completing this lesson should be able to: Develop a Layer 1 and 2 topology Gather information for both the pre-process and the process Create documentation during the course of the process Comply with TIA, EIA, and electrical standards Please note that this aligns with Farb s requests for her company s project. 1-4 CCNA 1: Networking Basics v3.0 F.A.R.B Case Study Copyright 2003, Cisco Systems, Inc.

5 Standards organizations When designing and building networks, it is necessary to ensure compliance with all applicable fire codes, building codes, and safety standards. Perhaps the most important part of the network design process is designing according to the EIA/TIA and ISO/IEC industry standards. The focus in this curriculum is on the standards for networking media that have been developed and issued by the following groups: ISO -- International Organization for Standardization (not an acronym, see glossary) IEEE -- Institute of Electrical and Electronics Engineers UL -- Underwriters Laboratories EIA -- Electronic Industries Alliance TIA -- Telecommunications Industry Association The latter two organizations jointly issue a list of standards called the TIA/EIA standards. In addition to these organizations, local, state, county, and national government agencies issue specifications and requirements that can impact the type of cabling that can be used in a local area network. It is also important to understand that these standards are constantly being reviewed and periodically updated to reflect new technologies and the ever-increasing requirements of voice and data networks. Just as new technologies are added to the standards, others are dropped or phased out. In many cases a network may include technologies that are no longer a part of the current standard or being eliminated. Typically, this does not require an immediate changeover, but these older, slower technologies are eventually replaced in favor of faster ones. Web link: Standards Definitions The primary standards that will affect layer design have been created by the TIA/EIA. The Telecommunications Industry Association (TIA) and Electronic Industries Alliance (EIA) are trade associations that jointly develop and publish a series of standards covering structured voice and data wiring for LANs. These industry standards evolved after the U.S. telephone industry deregulation in 1984, which 1-5 CCNA 1: Networking Basics v3.0 F.A.R.B Case Study Copyright 2003, Cisco Systems, Inc.

6 transferred responsibility for on premises cabling to the building owner. Prior to that, AT&T used proprietary cables and systems. Both TIA and EIA are accredited by the American National Standards Institute (ANSI, section 6.2.7) to develop voluntary industry standards for a wide variety of telecommunications products. This means that many standards are often labeled ANSI/TIA/EIA. The various committees and subcommittees of TIA/EIA develop standards for fiber optics, user premises equipment, network equipment, wireless communications, and satellite communications. TIA/EIA 568-A is the former Commercial Building Standard for Telecommunications Wiring. There are several supplements covering some of the newer, faster copper media. The standard and all of its supplements have been replaced by TIA/EIA-568-B. TIA/EIA-568-B is the current Cabling Standard. The standard specifies minimum requirements for telecommunications cabling, recommended topology and distance limits, media and connecting hardware performance specifications, and connector and pin assignments. This standard specifies the component and transmission requirements for media. TIA/EIA-568-B.1 specifies a generic telecommunications cabling system for commercial buildings that will support a multi-product, multi-vendor environment. TIA/EIA- 568-B.1.1 is an addendum that applies to 4-pair unshielded twistedpair (UTP) and 4-pair screened twisted-pair (ScTP) patch cables bend radius. TIA/EIA-568-B.2 specifies cabling components, transmission, system models, and the measurement procedures needed for verification of twisted pair cabling. TIA/EIA-568-B.3 specifies the component and transmission requirements for an optical fiber cabling system. TIA/EIA 569-A is the Commercial Building Standard for Telecommunications Pathways and Spaces. The standard specifies design and construction practices within and between buildings that are in support of telecommunications media and equipment. Specific standards are given for rooms or areas and pathways into and through which telecommunications equipment and media are installed. TIA/EIA-606 is the Administration Standard for the Telecommunications Infrastructure of Commercial Buildings including cable-labeling standards. The standard specifies that each hardware termination unit have some kind of unique identifier. This identifier must be marked on each termination hardware unit or on its label. When identifiers are used at the work area, station terminations must have a label on the faceplate, the housing, or the connector itself. All labels must meet legibility, defacement, and adhesion requirements as specified in UL969. TIA/EIA-607 is the standard for Commercial Building Grounding and Bonding Requirements for Telecommunications supports a multivendor, multi-product environment, as well as the grounding 1-6 CCNA 1: Networking Basics v3.0 F.A.R.B Case Study Copyright 2003, Cisco Systems, Inc.

7 practices for various systems that may be installed on customer premises. The standard specifies the exact interface points between the building grounding systems and the telecommunications equipment grounding configuration and specifies building grounding configurations needed to support this equipment. Electrical Safety Generally speaking, electrical current follows the path of least resistance. Because metals such as copper provide little resistance, they are frequently used as conductors for electrical current. Materials such as glass, rubber, and plastic provide more resistance and do not make good electrical conductors. Instead, these materials are frequently used as insulators. They are used to insulate conductors to prevent shock, fires, and short circuits. There are many different shapes of electrical outlets throughout the world. Two of the three connection points provide the power circuit. The third connector protects people and equipment from shocks and short circuits. This connector is called the safety ground connection. In electrical equipment where this is used, the safety ground wire is connected to any exposed metal part of the equipment. The purpose of connecting the safety ground to computing equipment is to prevent people from being exposed to hazardous voltage resulting from a wiring fault inside the device. An accidental connection between the hot wire and the chassis is an example of a wiring fault that could occur in a network device. If such a fault were to occur, the safety ground wire connected to the device would serve as a low resistance path to the earth ground. The safety ground connection provides a lower resistance path than the human body, thus reducing the risk of shock or electrocution. When properly installed, the low resistance path, provided by the safety ground wire, offers sufficiently low resistance and current carrying capacity to prevent the build up of hazardously high voltages. The circuit links directly to the hot connection to the earth. Telecommunications Room Requirements Layer one design is the largest component of the total network design. It involves the implementation of the preliminary designs gathered in the pre-process phase of the network design to create the Structured Cabling System. This includes, but is not limited to, creating the logical topology, creating the wiring map, selecting wiring closets, and cable selection. This design must conform to the appropriate standards organization s rules for design. Students completing this lesson should be able to: 1-7 CCNA 1: Networking Basics v3.0 F.A.R.B Case Study Copyright 2003, Cisco Systems, Inc.

8 Entrance facility List location and design requirements for telecommunications rooms Explain cable management design and specification List considerations for selecting and installing equipment racks Explain key environmental, safety, and power considerations in telecommunications room location, design, and installation The entrance facility (EF), or demarcation point (demarc), also called the point of presence (POP) or minimum point of entry (MPOE), provides the point at which outdoor cabling interfaces with the intrabuilding backbone cabling. It represents the boundary between the service provider's responsibility and that of the customer. In many buildings, this is the same point of presence (POP) for other utilities like electricity and water. The service provider is responsible for everything from the demarc to the service provider's facility. Everything from the demarc into the building is the customer's responsibility. The local telephone carrier is typically required to terminate cabling within 15 m (49.2 ft) of building penetration and to provide primary voltage protection. This is usually installed and provided by the service provider. TIA/EIA-569-A specifies the standards for the demarc space. The standards for the structure and size of the demarc space are based on the size of the building. In buildings larger than 2,000 usable square meters, a locked, dedicated, and enclosed room is recommended. The following are general guidelines when setting up a demarcation point space: One square meter of plywood wall mount should be allowed for each 20 square meter area of floor space. Surfaces that must be covered with plywood are painted with a fire retardant paint. Telecommunications and equipment rooms After the cable enters the building through the demarc, it travels to the telecommunications room, also called the main distribution facility (MDF). This is the center of the voice and data network. A telecommunications room, or TR, is the area within a building that houses the telecommunications cabling system equipment. This includes the mechanical terminations and/or cross-connect for the horizontal and backbone cabling system. It would be common for departmental or workgroup switches, hubs, and possibly routers to be located here. 1-8 CCNA 1: Networking Basics v3.0 F.A.R.B Case Study Copyright 2003, Cisco Systems, Inc.

9 The equipment room is a similar room that may exist in larger networks or in companies that specialize in telecommunications. An equipment room is essentially a large telecommunications room that may house the main distribution frame, PBXs, secondary voltage protection, satellite receivers, modulators, high speed Internet equipment, and so on. The design aspects of the equipment room are specified in the TIA/EIA-569-A standard. When designing a network, some designers will include both a telecommunications room and an equipment room depending on the amount of equipment and the needs of the customer. In this module, the telecommunications room is used to house the wiring and equipment. Regardless of whether there are separate rooms, both must conform to the standards produced by TIA/EIA-569-A, which are explained throughout this lesson. There are several factors that need to be considered when planning a network. The first is placement of the TR, since this space contains the networking cables and devices used. Accessibility and security are other factors to consider. A TR should be easily accessible, but it is a vulnerable point in the network and should be well secured. A disgruntled employee or someone intent on mischief can disable an entire network with a few seconds of work in the TR. Whether a TR is a dedicated room or a part of another room, it should be physically secure. Location restrictions and size requirements TRs should be located away from sources of electromagnetic interference like transformers, motors, x-ray, induction heaters, arc welders, radio, and radar. Water is another potential problem, so rooms with water pipes are best avoided, with the exception of a sprinkler system, which may be required by local fire codes. A dry gas fire suppression system is often used in place of a water sprinkler system. It will prevent any serious risk of damage by extinguishing a fire without the use of water. In many cases, the demarc space contains both water and electromagnetic sources, so it is not an ideal room for housing wiring and networking devices. This is the reason why most network equipment is housed away from the space where the utilities (power, water, and telephone) enter the building. In office buildings there is a need to have a TR on each floor. The TR on each floor is the junction between backbone and horizontal cabling. It can contain both voice and data telecommunications equipment, termination blocks, and cross-connect wiring. More than one TR per floor is required if the distance to a work area exceeds 90 m (295.3 ft), or if floor area served exceeds 1,000 square meters. TIA/EIA-569 specifies that the size of a TR must be at least 3.0 m x 3.4 m (9.8 ft x 11.2 ft) for each 1,000 square meters of work area served. 1-9 CCNA 1: Networking Basics v3.0 F.A.R.B Case Study Copyright 2003, Cisco Systems, Inc.

10 Room and equipment access TIA/EIA-569 specifies the size of the door and the type of locks used for a TR. The door of a TR should be at least 0.9 m (3 ft) wide and should swing open out of the room. This ensures an easy exit for workers. It also ensures against injury or upset equipment should someone open the door suddenly. The lock should be located on the outside of the door, but should allow anyone who is on the inside to exit at any time. A wiring hub and patch panel may be mounted to a wall with a hinged wall bracket or with a distribution rack. If the choice is a hinged wall bracket, the bracket must be attached to the plywood panel that covers the underlying wall surface. The purpose of the hinge is to allow the assembly to swing out so that workers and repairmen can easily access the backside of the wall. Care must be taken, however, to allow 48 cm (18.9 in) for the panel to swing out from the wall. If a distribution rack is used it must have a minimum 15.2 cm (6 in) of wall clearance for the equipment, plus another cm ( in) for physical access by workmen and repairmen. A 55.9 cm (22 in) floor plate, used to mount the distribution rack, will provide stability and will determine the minimum distance for its final position. If the patch panel, hub, and other equipment are mounted in a full equipment cabinet, they require at least 76.2 cm (28.6 in) of clearance in front, in order for the door to swing open. Typically, such equipment cabinets are 1.8 m high x.74 m wide x.66 m deep (5.9 ft x 2.4 ft x ft). Walls, floor, and ceiling specifications If there is only one TR in a building, then the floor on which it is located must be able to bear the load specified by the installation instructions included with the required equipment, with a minimum capability of 4.8 kpa (kilopascal), equivalent to 100 lb/ft². Where the TR serves as a secondary TR, the floor must be able to bear a minimum load of 2.4 kpa (50 lb/ft2). A minimum of two walls should be covered with 20 mm AC plywood that is at least 2.4 m (8 ft) high. If the TR serves as the primary TR for the building, then the telephone point of presence (POP), or demarc, may also be located inside the room. In such a case, the interior walls of the demarc, behind the PBX, should be covered from floor to ceiling with 20 mm plywood. A minimum of 4.6 m (15 ft) of wall space should be provided for the terminations and related equipment. In addition, fire prevention materials that meet all applicable codes (fire-rated plywood, fire-retardant paint on all interior walls, and so on) should be used in the construction of the telecommunications 1-10 CCNA 1: Networking Basics v3.0 F.A.R.B Case Study Copyright 2003, Cisco Systems, Inc.

11 room. Rooms must not have a dropped, or false ceiling. Failure to observe this specification could result in an insecure facility and allow for possible unauthorized access. Power outlets and lighting specifications A TR should have a minimum of two dedicated, non-switched, AC duplex electrical outlet receptacles, each on separate circuits. It should also have at least one duplex power outlet positioned every 1.8 m (6 ft) along each wall of the room and should be positioned 150 mm (6 in.) above the floor. A wall switch that controls the main lighting of the room should be placed immediately inside the door. An emergency power source should be considered and supplied, if available. While florescent lighting should be avoided for cable pathways because of the outside interference that it generates, it can be used in telecommunications rooms with proper installation. Lighting requirements for a telecommunications room specify a minimum of 500 lx (brightness of light equal to 50 candles) and that light fixtures be mounted a minimum of 2.6 m (8.5 ft) above the floor. Cable management The layout and management of cables and equipment is another facet of the structured cabling system. This section of the chapter explores the types of equipment that are needed in the TR, from cable management systems and equipment racks to wall fields and patch cords. Cable management devices are used for routing cables and providing a neat and orderly path for the cables. Cable management also eases cable additions and modification to the wiring system. There are many options for cable management in the TR. Cable baskets, ladder racks, conduits, and wire minders are all popular options Special cable management systems called innerducts are used exclusively for fiber-optic cables. They are plastic tubing that protect fiber-optic cabling and are then tied to ladder racks. Cable management will normally be associated with the type of patch panel that is used. For example, if the project uses Panduit patch panels, it will use Panduit cable management. Equipment racks The typical equipment in a TR is mounted on equipment racks. Racks are floor mounted metallic frames that support the installation of patch panels and active equipment like switches, routers, or servers. Patch panels, which use patch cords that are inserted by hand, and equipment that requires access to both front and back, are usually mounted on relay racks. A relay rack is the open-style freestanding rack that is used in a telecommunications room. It has two central vertical rails, as opposed to the rack frames used in other industries, 1-11 CCNA 1: Networking Basics v3.0 F.A.R.B Case Study Copyright 2003, Cisco Systems, Inc.

12 which are four-sided, often closed-in, with the mounting rails on each corner. Equipment must be placed into equipment racks with care. Considerations include ease of use and whether or not the equipment uses electricity, cable routing, and/or cable management. For example, a patch panel would not be placed high on a rack if a significant number of changes were to take place after the systems were installed. Convenience of use is a large consideration when planning the equipment layout. If active electronic equipment is also planned for the rack, plans must be made to power this equipment. Many designers put transientsuppressing power strips in the racks, and then run individual power cords down the rack rail to the surge suppressor. Powered equipment generates heat, which must be dispersed. Care must be taken not to block fans. Scalability is also a consideration in an equipment layout, as future growth should be accommodated. Space should be left on a rack for future patch panels, or in an initial layout, floor space should be left for future rack installations. Work area cabling Work area cabling extends from the telecommunications outlet in a room to the user workstation. Work area cabling is designed to be relatively simple to interconnect, so that it can be moved or changed relatively easily. Each work area serves a maximum of 10 square meters of usable floor space. Work area equipment includes the following components: Workstation equipment, such as computers, data terminals, telephones, fax machines, printers Cables, such as patch cables, modular cords, PC adapter cables, fiber jumpers Adapters external to the telecommunications outlet The TIA/EIA-568-B standard requires a minimum of two telecommunication outlets for each individual work area. The first outlet must be a four-pair, 100 Ω unshielded twisted pair (UTP) or screened twisted pair (ScTP) cable and connector. Category 5e is recommended for this outlet. There are three choices allowed by the standard for the second outlet: Four-pair, 100 Ω UTP or ScTP cable and connector (category 5e recommended) Two-fiber 62.5/125 µm or 50/125 µm optical fiber and connector 150 Ω shielded twisted pair (STP) cable and connector (not recommended for new installations) 1-12 CCNA 1: Networking Basics v3.0 F.A.R.B Case Study Copyright 2003, Cisco Systems, Inc.

13 Network Applications at FARB To estimate the amount of traffic that the network will carry will require you to understand the nature of the traffic. Database transfers seem to take a lot of bandwidth, as does videoconferencing. Web applications are often gentle on bandwidth, with the exception of streaming audio and video applications. The IT staff at FARB has a accumulated a list of software applications frequently used by the staff. This is broken out by which group of users uses which application. You can find the information about FARB and software requirement list in the Case Study Material Packet. Where does it all go? FARB has not progressed in its planning to the point that you have been told which users get what seats, nor even which department gets which area of the building. You have been handed some fairly developed blueprints from which to begin your efforts. They are entirely adequate for locating the Telecommunications Rooms in the project. You can find the drawings for Desk Assignments, Plumbing and HVAC, Rooms, and Electric Telephone and Lighting, along with the building plan legend, roof cross-section end view and side view, in the Case Study Material Packet. As is often the case, not all the information you need is on any one drawing. Further, some of the drawings seem to be not useful to your requirements. Nevertheless, they are a good start towards designing a network to meet FARB s requirements. The following set of hints should guide you as you negotiate the blueprints and start picking off information. Structured Cabling Case Study Hints Introduction: This case study will provide experience in practicing your networking and cabling skills. While working through the study, the goal will be designing the network layout for F.A.R.B Software Development, Ltd. You will reach this goal by performing several tasks involved in understanding the request for information and in deriving that information from the drawings. There are four layers of documentation: The first is a file that specifies President Cheryl Farb s idea for the network facility in the proposed new F.A.R.B building CCNA 1: Networking Basics v3.0 F.A.R.B Case Study Copyright 2003, Cisco Systems, Inc.

14 Second is a requirements document that has been worked up by the internal IP staff, or which you are part. This lists what must be connected where. Third are several sets of drawings of each of the four floors of the building. Fourth are some detail drawings to give you some idea of the methods of construction to be used. This will help you make decisions about cable routing. Take you time as you work through this case study. You will find much of the value will come from trying several different approaches. Discussion with class members and teammates may help solidify your understanding of the important topics this case study brings forward. Instructions: Locate the letter to the internal Support Team from President Cheryl Farb. This document shows 10 items on which your ideas and input are requested. The last part of the letter includes a forecast of the company growth. Here are the ten items. (Some of them have several steps): Recommendations of network equipment Recommendations on network cabling Any construction requirements Network equipment locations A wiring plan including: A horizontal and vertical logical layout A horizontal and vertical physical cabling layout A cabling plan for the server room Layouts of all MDFs and IDFs Work area cable outlet identification plan Security and fire prevention recommendations for server room, MDF and IDFs Electrical protection for equipment An IP addressing scheme for all devices on the network A cost projection for the implementation of the network, including: Equipment purchase costs Cabling and testing costs 1-14 CCNA 1: Networking Basics v3.0 F.A.R.B Case Study Copyright 2003, Cisco Systems, Inc.

15 Equipment installation costs Training and support costs A timeline for the implementation of the network. Following is a study guide that contains hints to help you complete these tasks. Hints 1-Recommendations of network equipment Look at pages 1 of Visio 1 Building Floor 1 (Ground Floor) Work through the following questions: What is the purpose of this floor? (Warehouse, reception area) What door will workers move freight through? (The large garage doors at the rear of the building) What doors will visitors come in? (Front doors off lobby that has reception station in it.) Where are visitors most likely to go after they sign in? (The conference room adjacent to the reception area) Where would you consider using wireless technology? (Guests could log on to the Internet via wireless in the reception and conference areas. Warehouse staff could use wireless for inventory.) If your department is someday tasked with wiring IP security cameras, what areas would you want to keep under surveillance? 1-15 CCNA 1: Networking Basics v3.0 F.A.R.B Case Study Copyright 2003, Cisco Systems, Inc.

16 (The two Secure storage areas, the rear walk through door, and the reception area) From where does the telephone company serve this building? (There is a point of presence (POP) next to the mechanical room.) What kind of lock should it have? (A good one that can be opened from the inside) Would the POP be a good place for the servers? (Possibly, it is certainly big enough, and it is close to the elevators for easy access.) Could you install the risers in the POP? (No. Check the floor above and you will see it has a conference room in that position). Where might you install the risers? (There is a small hallway adjacent to each stair way. Check that out) The horizontal cabling should always go parallel to walls. To get to Room 1.2 while staying parallel to walls will make a cable run of how many meters? Is this useable? (The distance is about 94 meters. This is barely enough to make the run, go down the walls, and join a work area connector. The designer must choose whether to cheat a little bit or to take advantage of the wireless system that is installed for the warehouse or conference room. This would present a security hassle but would solve a major problem.) 1-16 CCNA 1: Networking Basics v3.0 F.A.R.B Case Study Copyright 2003, Cisco Systems, Inc.

17 Floor 2 Floor two is dense with offices. It also contains the bottom floor of an auditorium. Not only would the auditorium be a possible candidate for wireless, it also may effect the routing of wires, as it extends several floors in height. Where might you put the Telecommunications Room on floor 2? You might consider using two of them. (Rooms 2.31, because if offers ceiling access to Room 3.10 above and to the mechanical room below. Might need to add one at 2.7 to accommodate the offices against that wall.) Floor 3 Floor 3 has large unplanned spaces in rooms 3.1 and 3.2. If you place the Telecommunications Room in room 3.10, how can you server these spaces, especially the far side of Room 3.2? (Wireless is a good solution for now. And then when the rooms are built out, put a second telecommunications room in either of them.) Floor 4 You notice a large deck on floor 4, as well as a banquet area with a piano. What would you need to provide network connectivity to this area? (You would only need one TR and some wireless to serve this area.) Where will you put the TR? (This is tough. Room 4.5 seems to be an office. However, Room 4.8 is blank. There is a hallway near room 4.10 that has an exterior door. As this is the 4th floor, you suspect an error. Further, Room 4.10 is shown with a door facing into the middle of a stairwell. Chances are you could mention these apparent errors, and request that at the same time they are corrected, that a TR be installed between Rooms 4.4 and 4.5.) This would be in a good alignment with the TRs on the floors below. You are now prepared to go to work. Count up the number of desks that would be served by each of these Telecommunications Rooms CCNA 1: Networking Basics v3.0 F.A.R.B Case Study Copyright 2003, Cisco Systems, Inc.

18 Multiply by two outlets per desk. Divide this number by 16, Round up as required, and order that many 16-Port Switches. That is your first item for the network equipment list. You will need rack frames to support those switches. Order two frames per room to start. Order patch panels to cover the lines you ve just specified. Mount these in the Continue until you have covered all network equipment for this job. It would be best to work this up in a spreadsheet. Network cabling. You determined how many work area outlets you needed for each TR in step 1. Use cabling of a high grade, Cat 5e or greater. Using a ruler map out the routes for these runs, and then pick off the dimensions. Add them all up, round up to the nearest 1000, add 1000, and then divide by 1000 this is how much cable (1000 foot boxes) you need. There is a trick here: Look at drawings called Visio-4 HVAC. This shows the Water and Air Conditioning duct work. Notice that there is both supply and return air. The ceiling is not a plenum ceiling. If local fire and building codes allow, you can specify a cable that is not plenum rated. This will result in considerable savings. Construction requirements. Next Steps You determined that you needed risers between each floor. This will require coring and that the bottom floor will pass through the mechanical space. This will require conduit. You also modified some rooms on the 4 th floor by adding the TR. You are now prepared to work your way through most of the rest of the case study. Have fun. Relax. Remember that the thinking and planning and false starts and discussion with your teammates is where the true value of this exercise lays CCNA 1: Networking Basics v3.0 F.A.R.B Case Study Copyright 2003, Cisco Systems, Inc.

Office of the Chief Information Officer Technical Note: IT-960-TN14 Effective: 05/25/2006 Last Revised: 02/17/2012 Issuing Office: OCIO

Office of the Chief Information Officer Technical Note: IT-960-TN14 Effective: 05/25/2006 Last Revised: 02/17/2012 Issuing Office: OCIO Cabling Standards Office of the Chief Information Officer Technical Note: IT-960-TN14 Effective: 05/25/2006 Last Revised: 02/17/2012 Issuing Office: OCIO 1. Purpose CABLING STANDARDS This technical note

More information

Tarleton State University. Specifications

Tarleton State University. Specifications Tarleton State University Campus Communication Infrastructure Specifications Cabling Standards Summary This document identifies Tarleton State University communication infrastructure standards. The communication

More information

ANSI/TIA/EIA-568-B Cabling Standard

ANSI/TIA/EIA-568-B Cabling Standard 83 Pair Numbers and Color Coding The conductors in a UTP cable are twisted in pairs and color coded so that each pair of wires can be easily identified and quickly terminated to the appropriate pin on

More information

Computer Network Design Guide Existing Systems 1 / 6

Computer Network Design Guide Existing Systems 1 / 6 COMPUTER NETWORK DESIGN GUIDELINE FOR EXISTING SYSTEMS DOCUMENT NUMBER: 16765 APPLICATION: ELEMENTARY, MIDDLE AND HIGH SCHOOL DATE OF ISSUE: 11-27-06 - First Issued NOTES: The attached guideline should

More information

Communications. UNM IT/Telecommunications Guide Specification Communications

Communications. UNM IT/Telecommunications Guide Specification Communications The material below covers specific information we definitely want to be included in the contract documents and may not be a completed specification section. This material is to be highlighted in your preliminary

More information

f) Telecommunications Equipment Rooms

f) Telecommunications Equipment Rooms SECTION 270000 - COMMUNICATIONS PART 1 - GENERAL 1.1 GENERAL REQUIREMENTS A. The Contractor is held responsible to be familiar with the provisions contained herein and with other Sections of this Specification

More information

ANSI/TIA/EIA-568-B Cabling Standard

ANSI/TIA/EIA-568-B Cabling Standard 73 ANSI/TIA/EIA-568-B Cabling Standard In the mid-1980s, consumers, contractors, vendors, and manufacturers became concerned about the lack of specifications relating to telecommunications cabling. Before

More information

The six major components of a structured wiring system are:

The six major components of a structured wiring system are: OBJECTIVES 1. Describe various ANSI/TIA/EIA standards for commercial buildings and residential settings. 2. Discuss the specific Technical Systems Bulletins that can affect telecommunications installations.

More information

AMP ACT 1 INSTALLING PREMISES CABLING SYSTEM. Welcome!!! Instructor : Nicholas Yeo

AMP ACT 1 INSTALLING PREMISES CABLING SYSTEM. Welcome!!! Instructor : Nicholas Yeo AMP ACT 1 INSTALLING PREMISES CABLING SYSTEM Welcome!!! Instructor : Nicholas Yeo AMP ACT 1 INSTALLING PREMISES CABLING SYSTEM Welcome!!! 2 Standards ISO CENELEC AS/NZS ANSI IEC CSA TIA EIA EN50173 AS/NZS

More information

Structured Cabling Supplement

Structured Cabling Supplement Sponsored by: Structured Cabling Supplement Cisco Networking Academy Program CCNA 1: Networking Basics v3.1 Objectives The Structured Cabling Supplement for CCNA provides curriculum and laboratory exercises

More information

ANSI/TIA/EIA-568-B Cabling Standard NOTE

ANSI/TIA/EIA-568-B Cabling Standard NOTE 95 ANSI/TIA/EIA-569-A Though the ANSI/TIA/EIA-568-B Standard describes the subsystems of a structured cabling system, the TIA has published a more thorough document called ANSI/TIA/EIA-569-A Commercial

More information

COMPUTER NETWORK WIRING SYSTEMS FOR PLCs

COMPUTER NETWORK WIRING SYSTEMS FOR PLCs SECTION 13744 COMPUTER NETWORK WIRING SYSTEMS FOR PLCs NOTE TO SPECIFIER: This section applies to primary learning centers only. PART 1 GENERAL 1.01 SUMMARY A. Section Includes: A complete computer network

More information

Design Guidelines for Facilities Construction:

Design Guidelines for Facilities Construction: Western Michigan University Office of Information Technology & Campus Planning, Design & Construction Design Guidelines for Facilities Construction: DESIGN GUIDELINE DG17-12 System Terminology, Definitions,

More information

Network Construction Guide Specification Telecommunications Infrastructure Standards V 2.6

Network Construction Guide Specification Telecommunications Infrastructure Standards V 2.6 Network Construction Guide Specification Telecommunications Infrastructure Standards 11-16-2018 V 2.6 Springfield Public Schools R12 Prepared by: Approved by: Released by: Springfield Public Schools R12

More information

Target Interface / Construction Compliance Inspection Checklist

Target Interface / Construction Compliance Inspection Checklist TES A. Roads-Service, Lanes Common Items Trails and service roads provide adequate access to buildings for maintenance B. Testing Results-provided to the local government construction representative Data

More information

Data Center Design and the ANSI/TIA-942 Standard

Data Center Design and the ANSI/TIA-942 Standard Data Center Design and the BICSI Regional Meeting Ellicott, MD Rick Foster RCDD,TLT Communications Infrastructure Group July 27, 2006 What is ANSI/TIA-942? Published by TIA in April 2005 Telecommunications

More information

TE100-S16 16-Port 10/100Mbps Fast Ethernet Switch. User s Guide

TE100-S16 16-Port 10/100Mbps Fast Ethernet Switch. User s Guide TE100-S16 16-Port 10/100Mbps Fast Ethernet Switch User s Guide FCC Warning This equipment has been tested and found to comply with the regulations for a Class A digital device, pursuant to Part 15 of the

More information

A. System design shall be completed by a Registered Communications Distribution Designer (RCDD).

A. System design shall be completed by a Registered Communications Distribution Designer (RCDD). UDIVISION 27 COMMUNICATIONS 27 00 00 COMMUNICATIONS A. System design shall be completed by a Registered Communications Distribution Designer (RCDD). B. Comply with American National Standards Institute

More information

NZQA registered unit standard version 2 Page 1 of 7. Demonstrate basic knowledge of electronic security data protocols and cabling

NZQA registered unit standard version 2 Page 1 of 7. Demonstrate basic knowledge of electronic security data protocols and cabling Page 1 of 7 Title Demonstrate basic knowledge of electronic security data protocols and cabling Level 3 Credits 15 Purpose This unit standard is for electronic security installers engaged in the installation

More information

INTERIM COMMUNICATIONS INFRASTRUCTURE PLANNING GUIDELINES

INTERIM COMMUNICATIONS INFRASTRUCTURE PLANNING GUIDELINES INTERIM COMMUNICATIONS INFRASTRUCTURE PLANNING GUIDELINES University of California, Riverside Computing and Communications April XX, 2001 R1V6 TABLE OF CONTENTS Introduction and Background...3 Outside

More information

Network+ Guide to Networks 7 th Edition

Network+ Guide to Networks 7 th Edition Network+ Guide to Networks 7 th Edition Chapter 4 Structured Cabling and Networking Elements 2016 Cengage Learning. May not be scanned, copied or duplicated, or posted to a publicly accessible website,

More information

TEG-S224TX 26-Port 10/100/1000Mbps Gigabit & Fast Ethernet Switch

TEG-S224TX 26-Port 10/100/1000Mbps Gigabit & Fast Ethernet Switch TEG-S224TX 26-Port 10/100/1000Mbps Gigabit & Fast Ethernet Switch with 2 1000BASE-T plus 24 10/100BASE-T ports User s Guide FCC Warning This equipment has been tested and found to comply with the regulations

More information

Newark, Delaware Architectural Engineering Senior Thesis Portfolio

Newark, Delaware Architectural Engineering Senior Thesis Portfolio Telecommunications System Design The represents the advancement of solar design in our world today. The building itself is an example of this. A Headquarters this dedicated to moving into the future should

More information

CCNA Discovery 4.0 Designing and Supporting Computer Networks

CCNA Discovery 4.0 Designing and Supporting Computer Networks CCNA Discovery 4.0 Designing and Supporting Computer Networks Characterizing Existing Network Chapter 3 1 Objectives 2 Creating a Network Diagram Typically, the first step in installing a new network is

More information

Chapter 10: Planning and Cabling Networks

Chapter 10: Planning and Cabling Networks Chapter 10: Planning and Cabling Networks Before using an IP phone, accessing instant messaging, or conducting any number of other interactions over a data network, we must connect end devices and intermediary

More information

AT&T Dedicated Internet (ADI formerly known as MIS) and Private Network Transport (PNT)

AT&T Dedicated Internet (ADI formerly known as MIS) and Private Network Transport (PNT) AT&T Dedicated Internet (ADI formerly known as MIS) and Private Network Transport (PNT) Site Preparation Guide 2015 AT&T Intellectual Property. All rights reserved. AT&T, the AT&T logo and all other AT&T

More information

CCNA Exploration Network Fundamentals. Chapter 10 Planning and Cabling Networks

CCNA Exploration Network Fundamentals. Chapter 10 Planning and Cabling Networks CCNA Exploration Network Fundamentals Chapter 10 Planning and Cabling Networks Updated: 15/07/2008 1 10.0.1 Introduction 2 10.0.1 Introduction The following have been covered in previous chapters: considered

More information

GSW-2453 Gigabit Chassis switch. User Guide

GSW-2453 Gigabit Chassis switch. User Guide GSW-2453 Gigabit Chassis switch User Guide Contents 1. INTRODUCTION... 1 Features... 1 Package Contents... 2 Ethernet Switching Technology... 2 2. HARDWARE DESCRIPTION... 4 Physical Dimension... 4 Front

More information

Telecommunications Structured Cabling Systems

Telecommunications Structured Cabling Systems Section 18 Telecommunications Structured Cabling Systems 18.1.0 Introduction 18.1.1 Important Codes and Standards 18.1.2 Comparison of ANSI/TIA/EIA, ISO/IEC, and CENELEC Cabling Standards 18.2.0 Major

More information

AT&T Dedicated Internet (ADI formerly known as MIS) and Private Network Transport (PNT)

AT&T Dedicated Internet (ADI formerly known as MIS) and Private Network Transport (PNT) AT&T Dedicated Internet (ADI formerly known as MIS) and Private Network Transport (PNT) Site Preparation Guide This guide is designed to assist local on-site contacts to understand what you will need to

More information

The following pages contain a guide for the installation

The following pages contain a guide for the installation INDEX The goal of this section is to illustrate how Siemon Company products can be used to support some of the most popular and emerging networks on the market. Section Contents 100Base-T....................................

More information

Copper Riser And Intrabuilding Cabling

Copper Riser And Intrabuilding Cabling Copper Riser And Intrabuilding Cabling PART 1: GENERAL The Contractor is held responsible to be familiar with the provisions contained herein and with other Sections of this Specification as applicable

More information

Los Angeles Community College District Design Standards

Los Angeles Community College District Design Standards LACCD Facilities Design Standards - Structural Cabling and Telecommunications Room Facilities Ver Approved: DTC February 0, 0 LACCD has developed the following Districtwide standard for IT infrastructure

More information

A/E REVIEW CHECKLIST TELECOMMUNICATIONS SYSTEMS

A/E REVIEW CHECKLIST TELECOMMUNICATIONS SYSTEMS A/E REVIEW CHECKLIST TELECOMMUNICATIONS SYSTEMS May 1, 2016 Reviewers should - Be aware that these checklists are not allinclusive but only provide important review items. Reviewers should - Use Checklists

More information

AT&T Virtual Private Network Service (VPN) and AT&T VPN Express

AT&T Virtual Private Network Service (VPN) and AT&T VPN Express AT&T Virtual Private Network Service (VPN) and AT&T VPN Express Site preparation guide This guide is designed to assist local on-site contacts to understand what you will need to accomplish in preparation

More information

3 Chapter Introduction. 3.2 Copper Cable

3 Chapter Introduction. 3.2 Copper Cable 3 Chapter 3 3.1 Introduction The Network Media is the device that physically carries the data from computer to computer. The three major types of network media are: Copper Cable Fiber-Optic Cable Wireless

More information

TIA/EIA 568A Sub-system HORIZONTAL CABLING

TIA/EIA 568A Sub-system HORIZONTAL CABLING TIA/EIA 568A Sub-system HORIZONTAL CABLING Horizontal Cabling WA 100(120)Ω CAT 3 TP TP 100(120)Ω CAT 5 150Ω STP-A 62.5(50)/125µ FIBER HC/FD WA Horizontal Media Considerations UTP/FTP Consider bandwidth,

More information

Installation Notes TII Model 341 Protector

Installation Notes TII Model 341 Protector Installation Notes TII Model 341 Protector (ATT-IS PEC 32918) for MERLIN Communications System In Range Out of Building (IROB) Station Installation By Trained Technician Only WARNING: Failure to follow

More information

Siemon PON Fiber Cabling Solutions

Siemon PON Fiber Cabling Solutions Siemon PON Fiber Cabling Solutions WWW.SIEMON.COM 8 Siemon Enterprise PON Fiber Cabling Solution Siemon Enterprise Passive Optical Network (PON) Fiber Cabling Solution improves the modularity, flexibility

More information

Cabling Infrastructure

Cabling Infrastructure Introduction Ethernet Banking on Structured Cabling Technology Drivers Classification of Cables Fibre-optic cable Cables in building Cabling Infrastructure Cabling systems address the networking requirements

More information

Ether-FSH2400C 24-port 10/100Base-TX Switch

Ether-FSH2400C 24-port 10/100Base-TX Switch Ether-FSH2400C 24-port 10/100Base-TX Switch User s Manual FCC STATEMENT This equipment has been tested and found to comply with the limits for a class A device, pursuant to part 15 of the FCC rules. These

More information

FSW-1610TX FSW-2410TX

FSW-1610TX FSW-2410TX LevelOne FSW-1610TX FSW-2410TX 16/24-Port Fast Ethernet Switch User Manual Version 1.1-0609 FCC Warning This equipment has been tested and found to comply with the regulations for a Class A digital device,

More information

SPOS (Station Point of Sale) 200. SFTP (Station Fare Transaction Processor) 35. CQD (Card Query Device) 35. HCR (Handheld Card Reader) Cradles 120

SPOS (Station Point of Sale) 200. SFTP (Station Fare Transaction Processor) 35. CQD (Card Query Device) 35. HCR (Handheld Card Reader) Cradles 120 DESIGN GUIDELINES PRESTO INSTALLATION & CONNECTIVITY PAGE 1 of 4 ELECTRICAL CONNECTIVITY AND WIRING Communications Conduits Conduits designated for Presto equipment data wiring shall be clearly identified

More information

AT&T Switched Ethernet Service SM

AT&T Switched Ethernet Service SM Site Preparation Guide AT&T Switched Ethernet Service SM December 2016 2016 AT&T Intellectual Property. All rights reserved. AT&T, Globe logo, Mobilizing Your World and DIRECTV are registered trademarks

More information

Data Cabling / Low Voltage Technology Specifications

Data Cabling / Low Voltage Technology Specifications P19-02- Forsyth County Schools Data Cabling / Low Voltage Technology Specifications 1. General requirements 1.1 On premise connectivity All building closets (IDF) aside from the main closet (MDF) shall

More information

E. Numbering and Labeling Pathway components. In general, pathway components are not labeled.

E. Numbering and Labeling Pathway components. In general, pathway components are not labeled. 27 05 53 Identification (Labeling) for Communications Systems (Revision date: 3/6/13) 1.0 Purpose A. These guidelines provide requirements for designers to incorporate into bid documents. They are part

More information

AT&T Virtual Private Network Service (VPN) and AT&T VPN Express

AT&T Virtual Private Network Service (VPN) and AT&T VPN Express AT&T Virtual Private Network Service (VPN) and AT&T VPN Express Site Preparation Guide 2017 AT&T Intellectual Property. All rights reserved. AT&T, Globe logo, Mobilizing Your World and DIRECTV are registered

More information

Bonding and grounding NETCONNECT copper cabling systems

Bonding and grounding NETCONNECT copper cabling systems White paper Bonding and grounding NETCONNECT copper cabling systems A complete review of bonding and grounding for copper twisted-pair cabling systems www.commscope.com 1 Taking the guesswork out of grounding

More information

SPECIFICATION STANDARD COPPER RISER AND INTRABUILDING CABLING

SPECIFICATION STANDARD COPPER RISER AND INTRABUILDING CABLING PART 1: GENERAL 1.01 SCOPE OF WORK A. The Designer and Contractor are responsible to be familiar with the provisions contained herein and with other Sections of this Specification as applicable to the

More information

Classroom WiFi Network Infrastructure Plan

Classroom WiFi Network Infrastructure Plan Seattle Archdiocese Office for Catholic Schools Design for Classroom WiFi Network Modernization Guidelines for IT Physical Infrastructure Design and Specifications This document provides guidelines to

More information

FIBER OPTIC HARDWARE STEVE PAULOV

FIBER OPTIC HARDWARE STEVE PAULOV C H A P T E R 7 FIBER OPTIC HARDWARE STEVE PAULOV The main purpose for hardware is to protect and organize splice and termination points. Hardware can be divided into two categories; indoor and outdoor.

More information

iconverter 2-Module Power Chassis

iconverter 2-Module Power Chassis iconverter 2-Module Power Chassis User Manual 38 Tesla, Irvine, CA 92618 USA Phone: (949) 250-6510; Fax: (949) 250-6514 Page 1 Warning The operating description in this Instruction Manual is for use by

More information

NZQA unit standard version 3 Page 1 of 5. Demonstrate knowledge for telecommunications premises network cablers

NZQA unit standard version 3 Page 1 of 5. Demonstrate knowledge for telecommunications premises network cablers Page 1 of 5 Title Demonstrate knowledge for telecommunications premises network cablers Level 2 Credits 2 Purpose This unit standard is for people installing and maintaining telecommunications cables on

More information

SECTION 5 -- EQUIPMENT LAYOUT & EQUIPMENT ENVIRONMENTS

SECTION 5 -- EQUIPMENT LAYOUT & EQUIPMENT ENVIRONMENTS SECTION 5 -- EQUIPMENT LAYOUT & EQUIPMENT ENVIRONMENTS CONTENTS PAGE 1. GENERAL... 5-1 1.1. Introduction... 5-1 1.2. Equipment Layout Requirements... 5-1 2. EQUIPMENT FRAMES... 5-2 2.1. Introduction...

More information

With the publication. Make the right connection: Bonding a shielded system. installation

With the publication. Make the right connection: Bonding a shielded system. installation Make the right connection: Bonding a shielded system installation With the publication of the IEEE 802.3an 10GBase-T standard in 2006, Augmented Category 6 (i.e., Category 6A) cabling systems are being

More information

Cables and Connectors

Cables and Connectors Module 2 Cables and Connectors Twisted Pair Two wires that carry the data signals (one conductor carries a positive signal; one carries a negative signal). Two wires are twisted to reduce the effects of

More information

Cabling a Data Center to TIA-942 Standard

Cabling a Data Center to TIA-942 Standard Cabling a Data Center to TIA-942 Standard BICSI 2006 Winter Conference Wednesday, January 25 th 2006 at 9:15 am Gary J. Bernstein, RCDD HellermannTyton Corporation Agenda Overview of TIA-942 Data Center

More information

Checklist for building an edge data center

Checklist for building an edge data center Checklist for building an edge data center Building an edge data center to provide a cloud computing environment within a service provider central office can be a complex endeavor. It requires lots of

More information

Fiber Backbone Cabling in Buildings

Fiber Backbone Cabling in Buildings White Paper Fiber Backbone Cabling in Buildings www.commscope.com Contents Introduction 3 Backbone Cabling Speeds 3 Optical Fiber in the Backbone 4 b/s Optical Fiber Backbone 4 Migrating to 40 Gbps and

More information

OMEGA MODULAR PATCH PANEL EMPTY ENCLOSURE

OMEGA MODULAR PATCH PANEL EMPTY ENCLOSURE OMEGA MODULAR PATCH PANEL EMPTY ENCLOSURE The Omega MPP enclosure is based on a 19" frame, with 4 empty module slots for MPP modules. Highly flexible : any mix between twisted pair and optical fiber modules.

More information

The Threaded Case Study

The Threaded Case Study Cisco Networking Academy Program Semesters III and IV Instructor: Chris Widmer The Threaded Case Study OBJECTIVE The purpose of the Threaded Case Study is to allow you to apply the knowledge that you have

More information

Internetworking is connecting two or more computer networks with some sort of routing device to exchange traffic back and forth, and guide traffic on

Internetworking is connecting two or more computer networks with some sort of routing device to exchange traffic back and forth, and guide traffic on CBCN4103 Internetworking is connecting two or more computer networks with some sort of routing device to exchange traffic back and forth, and guide traffic on the correct path across the complete network

More information

Industrial 5-Port Fast Ethernet Switches with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541 PoE Model: KSD-541-P. Installation Guide

Industrial 5-Port Fast Ethernet Switches with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541 PoE Model: KSD-541-P. Installation Guide Industrial 5-Port Fast Ethernet Switches with SFP Slot and optional 4 PoE PSE Ports Basic Model: KSD-541 PoE Model: KSD-541-P Installation Guide DOC.080104-1- (C) 2008 KTI Networks Inc. All rights reserved.

More information

Application Note. Data Center Standards and Layouts

Application Note. Data Center Standards and Layouts Application Note Data Center Standards and Layouts 1. Data Center Standards In earlier times, a room in which one or more servers, a telephone system and active network components were located was often

More information

Government of Prince Edward Island Structured Cabling Standards August 24, 2009

Government of Prince Edward Island Structured Cabling Standards August 24, 2009 Government of Prince Edward Island Structured Cabling Standards August 24, 2009 Emerging technologies dictate that it is no longer allowable to simply integrate various manufacturers components into a

More information

Physical Layer V What does the physical layer provide?

Physical Layer V What does the physical layer provide? SEMESTER 1 Chapter 8 Physical Layer V 4.0 90 Points 8.1.1 What does the physical layer provide? What are the four elements of delivering frames across the media? 8.1.2 What are the three basic forms of

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD ISO/IEC 18010 2002 AMENDMENT 1 2005-12 Amendment 1 Information technology Pathways and spaces for customer premises cabling IEC 2005 Droits de reproduction réservés Copyright - all

More information

Suite Anthony Lopresti T +1 (212) Ethan Silverstein T +1 (212)

Suite Anthony Lopresti T +1 (212) Ethan Silverstein T +1 (212) Suite 1003 TENTH FLOOR Suite 800 Workstations 30 Offices 3 Conference 2 Informal Meeting 1 Reception 1 Total Headcount E I GH T H F L O O R 34 Suite 600 SIXTH FLOOR Suite 511 Office Intensive Workstations

More information

Universal connectivity grid design guide

Universal connectivity grid design guide Universal connectivity grid design guide SYSTIMAX Solutions from CommScope May 2017 Contents Introduction 3 Commercial building network overview 3 Zone cabling 4 Universal connectivity grid 4 UCG cell

More information

Communication

Communication 27 00 00 Communication 1.01 Scope of Standard A. These guidelines identify and define Texas State University requirements and policies for designing and installing telecommunications infrastructure and

More information

IBDN 110 Cross-Connect System

IBDN 110 Cross-Connect System IBDN 110 Cross-Connect System Connecting & Wiring Blocks Cross-Connect Kits Wall Mount Frame Kits Patch Cords Labels & Management Accessories For For A Complete End-to-End 110 Solution what s coming next.

More information

REFERENCE T3 R3 T2 R1 T1 R2 T4 R4 WHT GRN T2 R2 T3 R1 T1 R3 T4 R4 WHT

REFERENCE T3 R3 T2 R1 T1 R2 T4 R4 WHT GRN T2 R2 T3 R1 T1 R3 T4 R4 WHT P O L A R I Z A T I O N G L O S S A R Y & A L P H A N U M E R I C REFERENCE S Y S T E M A P P L I C A T I O N S C A B L I N G S T A N D A R D S 1 2 3 4 5 6 7 8 T3 R3 T2 R1 T1 R2 T4 R4 WHT GRN GRN WHT ORG

More information

PoE Powered 10/100BASE-TX to 100BASE-FX Media Converters. KC-351 Series. Installation Guide

PoE Powered 10/100BASE-TX to 100BASE-FX Media Converters. KC-351 Series. Installation Guide PoE Powered 10/100BASE-TX to 100BASE-FX Media Converters KC-351 Series Installation Guide -1- DOC.070820-KC-351 (C) 2007 KTI Networks Inc. All rights reserved. No part of this documentation may be reproduced

More information

LACCD IT Design Standards

LACCD IT Design Standards LACCD IT Design Standards March 1 2009 This document establishes a uniform standard for the design of IT Structured Cabling for LACCD. It ensures a secure, consistent, robust system with physical and low-voltage

More information

Installing the Cisco MDS 9020 Fabric Switch

Installing the Cisco MDS 9020 Fabric Switch CHAPTER 2 This chapter describes how to install the Cisco MDS 9020 Fabric Switch and its components, and it includes the following information: Pre-Installation, page 2-2 Installing the Switch in a Cabinet

More information

Physical and Environmental Security Standards

Physical and Environmental Security Standards Physical and Environmental Security Standards Table of Contents 1. SECURE AREAS... 2 1.1 PHYSICAL SECURITY PERIMETER... 2 1.2 PHYSICAL ENTRY CONTROLS... 3 1.3 SECURING OFFICES, ROOMS AND FACILITIES...

More information

Atras Network Communications

Atras Network Communications Atras Network Communications Guide to Information and Communications Technology (ICT) Standards developed and published by the Telecommunications Industry Association (TIA) The Telecommunications Industry

More information

Peter Sharp RCDD IBI Group

Peter Sharp RCDD IBI Group Peter Sharp RCDD IBI Group Who am I? Presenter Credentials Electrical Engineering Consultant Specialties in communications, electronics and computer sciences, In practice for more than 40 years Member

More information

Industrial 5-Port Fast Ethernet Switches. with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541. PoE Model: KSD-541-HP. Installation Guide

Industrial 5-Port Fast Ethernet Switches. with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541. PoE Model: KSD-541-HP. Installation Guide Industrial 5-Port Fast Ethernet Switches with SFP Slot and optional 4 PoE PSE Ports Basic Model: KSD-541 PoE Model: KSD-541-HP Installation Guide DOC.141201-1- (C) 2014 KTI Networks Inc. All rights reserved.

More information

SECTION COMMUNICATIONS OPTICAL FIBER BACKBONE CABLING

SECTION COMMUNICATIONS OPTICAL FIBER BACKBONE CABLING SECTION 27 13 23 COMMUNICATIONS OPTICAL FIBER BACKBONE CABLING PART 1 GENERAL 1.01 DESCRIPTION A. The work covered by this section of the Specifications includes all labor necessary to perform and complete

More information

Section A5. Standard Telephone Entry Systems. This Price Schedule is effective April 1, Date Page Comment

Section A5. Standard Telephone Entry Systems. This Price Schedule is effective April 1, Date Page Comment April 2015 PRICE SCHEDULE A 2.0 Section A5 This Price Schedule is effective April 1, 2015. Date Page Comment 4-1-15 All April, 2015 Price Schedule update. Prices and specifications subject to change without

More information

4 10/100/1000T Mini-GBIC with 4 IEEE 802.3at High Power PoE Industrial Wide Temperature Switch. User Manual SISTP LRT

4 10/100/1000T Mini-GBIC with 4 IEEE 802.3at High Power PoE Industrial Wide Temperature Switch. User Manual SISTP LRT 4 10/100/1000T + 2 1000 Mini-GBIC with 4 IEEE 802.3at High Power PoE Industrial Wide Temperature Switch User Manual V1.0 September-2013 FCC Warning This Equipment has been tested and found to comply with

More information

(Network Programming) Basic Networking Hardware

(Network Programming) Basic Networking Hardware EEE 448 Computer Networks with (Network Programming) Basic Networking Hardware Lecture #2 Dept of Electrical and Electronics Engineering Çukurova University Agenda What is a network device? Network Media

More information

v2.5 was updated May 10, v2.6 is an updated copy from March 1, 2017.

v2.5 was updated May 10, v2.6 is an updated copy from March 1, 2017. Changes in v2.6: v2.5 was updated May 10, 2016. v2.6 is an updated copy from March 1, 2017. Modifications to 4. Horizontal Pathways section with feedback incorporated from UofA Facilities and Operations

More information

Cabling Infrastructure

Cabling Infrastructure Presented by: Jim McGlynn PE RCDD/LAN Specialist O Neal/Gaj A telecommunications and technology consulting firm that specializes in the hospitality industry. Program Discussion: Goals Technology Definitions

More information

SYSTIMAX GigaSPEED Xpress Solution Design Guidelines

SYSTIMAX GigaSPEED Xpress Solution Design Guidelines Design Guidelines Issue 2 August 2010 Contents 1.0 Overview 3 2.0 Power Separation 4 3.0 Bonding and Grounding 4 4.0 Administration and Labeling 5 5.0 General Cable Guidelines 5 6.0 Bundling and Alien

More information

COMPUTER SKILLS COMP101

COMPUTER SKILLS COMP101 COMPUTER SKILLS COMP101 Chapter 4 Introduction to Computer Networks Definitions and Terminologies Computer Network A network consists of two or more computers that are linked in order to share resources

More information

How You Can Optimize Passive Optical LAN Through Structured Cabling

How You Can Optimize Passive Optical LAN Through Structured Cabling How You Can Optimize Passive Optical LAN Through Structured Cabling Author: Stephane Bourgeois Director Technology Strategy Table of Contents Overview 1 What is POLAN? 1, 2 Deploying a POLAN 2 The Benefits

More information

Preparing to Install the Cisco AS5350XM Universal Gateway

Preparing to Install the Cisco AS5350XM Universal Gateway CHAPTER 2 Preparing to Install the Cisco AS5350XM Universal Gateway This chapter describes the tasks you must perform before you begin to install the Cisco AS5350XM universal gateway and includes the following

More information

TE100-DX16R/DX24R/DX32R 16/24/32 Ports Ethernet/Fast Ethernet Dual-Speed Stackable Hubs User s Guide

TE100-DX16R/DX24R/DX32R 16/24/32 Ports Ethernet/Fast Ethernet Dual-Speed Stackable Hubs User s Guide TE100-DX16R/DX24R/DX32R 16/24/32 Ports Ethernet/Fast Ethernet Dual-Speed Stackable Hubs User s Guide Rev. 01 (JULY, 1998) 505-0100-004 Printed In Taiwan RECYCLABLE Dual-Speed Stackable Hubs User s Guide

More information

HITEC 2003 Produced by Hospitality Financial and Technology Professionals

HITEC 2003 Produced by Hospitality Financial and Technology Professionals Infrastructure of a Hotel Dan Phillips Bob Stoutenburgh David Hostetter Presenters Dan Phillips Founding partner and COO of ITS Inc., Dan manages and organizes telecommunications and data projects for

More information

Omnitron Systems Technology, Inc. 1. iconverter. 19-Module Managed Power Chassis User s Manual

Omnitron Systems Technology, Inc. 1. iconverter. 19-Module Managed Power Chassis User s Manual Omnitron Systems Technology, Inc. 1 iconverter 19-Module Managed Power Chassis User s Manual 27 Mauchly, #201, Irvine, CA 92618 Phone: (949) 250-6510; Fax: (949) 250-6514 2 Omnitron Systems Technology,

More information

Networking Fundamentals

Networking Fundamentals Networking Fundamentals Cable types and connectors Fiber A fiber optic cable consists of a bundle of glass threads, each of which is capable of transmitting messages modulated onto light waves. Fiber optics

More information

Leveraging the Structured Cabling System for Security Applications. Mark Dearing, RCDD Leviton Network Solutions

Leveraging the Structured Cabling System for Security Applications. Mark Dearing, RCDD Leviton Network Solutions Leveraging the Structured Cabling System for Security Applications Mark Dearing, RCDD Leviton Network Solutions Trends - Cable Category Mix Source: Leviton projections based on market growth rates Over

More information

Optimization and Speed: Two Critical Standards Enabling Next Generation Networks. Stephanie Montgomery, TIA Brett Lane, Panduit

Optimization and Speed: Two Critical Standards Enabling Next Generation Networks. Stephanie Montgomery, TIA Brett Lane, Panduit Optimization and Speed: Two Critical Standards Enabling Next Generation Networks Stephanie Montgomery, TIA Brett Lane, Panduit Structure of TIA Standards 2 A family of Standards ANSI/TIA-942-A Telecommunications

More information

Target Interface / Construction Compliance Inspection Checklist

Target Interface / Construction Compliance Inspection Checklist A. Targets Quantities meet DD9, applicable TC -, and CEHNC Design Guide 0-- Oriented to face firing line or firing positions/points B. Roads-Service, Lanes Number of lanes meets DD 9, applicable TC -,

More information

User Manual. AN A GPON Optical Network Unit. Version: A. Code: MN Date: December 2011

User Manual. AN A GPON Optical Network Unit. Version: A. Code: MN Date: December 2011 An Expert in Optical Communications User Manual AN5506-01-A GPON Optical Network Unit Version: A Code: MN000000943 Date: December 2011 FiberHome Telecommunication Technologies Co., Ltd. Version Version

More information

STATE OF NEW JERSEY BUREAUS OF ITS ENGINEERING AND SAFETY & DATA DEVELOPMENT DEPARTMENT OF TRANSPORTATION TRENTON, NEW JERSEY 08625

STATE OF NEW JERSEY BUREAUS OF ITS ENGINEERING AND SAFETY & DATA DEVELOPMENT DEPARTMENT OF TRANSPORTATION TRENTON, NEW JERSEY 08625 September 2011 STATE OF NEW JERSEY BUREAUS OF ITS ENGINEERING AND SAFETY & DATA DEVELOPMENT DEPARTMENT OF TRANSPORTATION TRENTON, NEW JERSEY 08625 MATERIAL SPECIFICATIONS FOR WEIGH-IN-MOTION SYSTEM The

More information

The Riser as a Contract Document. Peter Sharp, RCDD

The Riser as a Contract Document. Peter Sharp, RCDD The Riser as a Contract Document Peter Sharp, RCDD IBI Group 1 1 Who am I? Presenter Credentials Electrical Engineer Specialties in communications, electronics and computer sciences, In practice for 40

More information

PN Telecommunications Infrastructure Standard for Data Centers Draft 2.0 July 9, 2003

PN Telecommunications Infrastructure Standard for Data Centers Draft 2.0 July 9, 2003 0 NOTICE: PN--00 Telecommunications Infrastructure Standard for Data Centers Draft.0 July, 00 0 This contribution has been prepared to assist the TR- Standards Committee. It is offered to the Committee

More information