1 MANUAL INSTALLATION Multi-Variable Monitor MVM Series Issue Date: 02/07/ Price Industries Limited. All rights reserved.

2 TABLE OF CONTENTS Product Overview General...1 MVM Specifications...1 Included in Package...2 Sample Wiring Diagram...3 Installation & Mounting Instructions Wall Cutout and Bracket Installation...4 Display Navigation Functionality...5 Home Screen...6 MVM Operation...7 Settings...8 Login Screen...9 Networking & Setup BACnet Integration...10 Maintenance Troubleshooting...11 TECH TIP Short circuit or incorrect wiring may permanently damage the controls or other equipment. Ensure proper wiring practices. Technical Support For local area support, please contact your local Price Critical Controls Representative For factory technical support, please contact: P: E: W:

3 PRODUCT OVERVIEW General The Price Multi-Variable Monitor (MVM) is a touchscreen monitor that can be used to display and adjust settings from multiple devices on a BACnet network. The MVM supports both BACnet MS/TP and BACnet IP to connect with the room level devices. The MVM can be used to display any BACnet point including alarm status, room temperature and humidity, room pressure, air change rate per hour, and occupancy. The MVM is able to connect to multiple devices, which allows it to be used as a remote station to monitor multiple rooms while displaying critical information for each room. An easy to use interface allows the user to quickly and easily identify the source of any alarms. Audible alarms are available locally and remotely. Password protection ensures that only administrators can change room settings. FRONT DISPLAY MVM Specifications Dimensions: 7" 8.8 in. (223 mm) x 6.4 in. (162 mm) x 2.6 in (65 mm) 15" 15.5 in. (394 mm) x 12.5 in. (318 mm) x 2.6 in (65 mm) Display Type: 7" Capacitive touch, 7.0 in. (178 mm), TFT, dimmable 15" Capacitive touch, 15.0 in. (381 mm), TFT, dimmable Resolution: 7" 800 px x 480 px, colors 15" 1024 px x 768 px, colors Input Power: 7" 24 VAC, 14 VA, Class 2 15" 24 VAC, 25 VA, Class 2 Environmental (operating): 550 F to 105 F (10 C to 40 C), 10% to 90% R.H. (non-condensing) Communication Protocol: BACnet MS/TP, BACnet IP Face: Glass, IP54 pricecriticalcontrols.com Multi-Variable Monitor - Manual 1

4 MANUAL INSTALLATION MVM Series Issue Date: 07/22/ Price Industries Limited. All rights reserved. Multi-Variable Monitor Product Overview Included in Package INCLUDED ITEMS 1. Multi-Variable Monitor Quantity: 1 2. Mounting Bracket Quantity: 1 3. Installation Manual Quantity: 1 Please ensure you have all components before proceeding. Inspect components for shipping damage. Do not install any components that appear damaged, contact your local Price Sales Representative for quick ship replacements. For the latest information and videos please visit 1. MULTI-VARIABLE MONITOR (MVM) 3. INSTALLATION MANUAL 2. MOUNTING BRACKET Multi-Variable Monitor 2 Multi-Variable Monitor - Manual pricecriticalcontrols.com

5 PRODUCT OVERVIEW Sample Wiring Diagram pricecriticalcontrols.com Multi-Variable Monitor - Manual 3

6 INSTALLATION & MOUNTING INSTRUCTIONS Ensure you have all components necessary for installation. Inspect components for signs of shipping/ handling damage. Do not proceed if you suspect any components are damaged. WALL MOUNT DIMENSIONS CABLE ENTRIES N Q R M P S K Dim. 7" 15" J 7.677" " K 5.63" " L 8.11" 14.37" M 0.827" 1.87" N 2.441" 5.217" P 1.181" 1.839" Q 2.756" 3.543" R 1.969" 3.937" S 1.969" 3.937" J L MOUNTING BRACKET AND MVM INSTALLATION 4 Multi-Variable Monitor - Manual pricecriticalcontrols.com

7 DISPLAY NAVIGATION Functionality The MVM is designed to provide ease of use monitoring of multiple variables from Price controllers. The MVM Home Screen provides monitoring information in a simple format displaying information including Room Status and Isolation Mode. Features 1. Password protected menus. 2. Monitor up to 8 rooms simultaneously. 3. Audible Alarms - available locally and remotely. The home page will display in one of the following configurations, depending on the number of rooms that are being monitored. SINGLE ROOM CONFIGURATION TWO ROOM CONFIGURATION THREE ROOM CONFIGURATION FOUR ROOM CONFIGURATION SIX ROOM CONFIGURATION EIGHT ROOM CONFIGURATION pricecriticalcontrols.com Multi-Variable Monitor - Manual 5

8 DISPLAY NAVIGATION Home Screen Upon startup of the MVM, the Home Screen is displayed. This Home Screen provides the user with a clear indication of the room mode, status, and pressure reading. 1 Menu Button Opens the navigation menu which allows access to the login screen and the settings menu Room Name Displays the name of the room being monitored. This is configurable and is password protected. 3 3 Room Pressure The current room pressure reading Room Status Indicates whether the room is maintaining the desired setpoints in its current mode. Isolation Mode Indicates whether the room is in Negative or Positive Isolation mode. 6 Multi-Variable Monitor - Manual pricecriticalcontrols.com

9 DISPLAY NAVIGATION MVM Operation When fully set up, the MVM can be interfaced with Price controllers to monitor their room status. The MVM will change its display to match the room status of the controller that is being monitored. Status LCD Display Normal - Pressure reading within low / high set points Caution - Example: Open Door Alarm - Example: Pressure reading outside low/high alarm set points Setback - Pressure measured but no alarms pricecriticalcontrols.com Multi-Variable Monitor - Manual 7

10 DISPLAY NAVIGATION Settings The Settings are accessible through the Home Screen and are password protected (see previous section). These menus allow the user to change any of the configurable options on the MVM. TCP/IP Allows the user to adjust the IP address of the device when connecting to a local network. System Setup Menu TCP/IP BACnet CEA709 CEA852/RNI Date/Time Commands Storage Info About Exit BACnet Allows the user to adjust the BACnet settings of the MVM. CEA709 Not required. CEA852/RNI Not required. Date/Time Can be used to set the date and time of the device. Commands Allows the user to perform a number of commands such as calibrating the touch screen or resetting the device. Storage Not required. Info Allows the user to adjust the screen brightness and the speaker volume. About Shows the device firmware. Exit Closes the setup menu. 8 Multi-Variable Monitor - Manual pricecriticalcontrols.com

11 DISPLAY NAVIGATION Login Screen The login screen is used to enter passcodes to gain access to locked features. 1. Press to enter the assigned passcode. 2. Press to change password. 3. Displays current access level. Up to 15 levels of access can be assigned. 4. Press to log-out and revert access level back to pricecriticalcontrols.com Multi-Variable Monitor - Manual 9

12 - + Multi-Variable Monitor NETWORKING AND SETUP BACnet Integration The MVM is a Native BACnet MS/TP and BACnet IP device. Physical connection The BACnet MS/TP network segment must be run in a daisy-chain configuration. Recommended MS/TP cable: Twisted pair Shielded (either foil or braided shields) Characteristic impedance: ohms Capacitance between conductors: less than 30pF per foot (100pF per meter) Optional 3rd conductor for reference connection. Depending on the existing architecture, the MS/TP segment can be run as a 2-wire network or a 3-wire network. Using a 2-wire network architecture, daisy-chain both the + and - connections of all devices on the network segment using the twisted-pair data cables. Polarity must be maintained across all devices as shown in Figure 1. Using a 3-wire network architecture, daisy-chain the + and - connections of all devices using the twisted-pair data cables, and daisy-chain the network common reference signal using the 3rd conductor (if present in cable) as shown in Figure 2. Do not use the wire shield as the network common reference conductor. Polarity must be maintained across all devices. NOTE: When using non-isolated power supplies (ie. Transformer secondary common connected to ground), 24 VAC polarity is critical to network communication and must not be reversed on any device. Network cable shielding When using shielded cable, the braid/foil shield must be grounded at one end of the network segment only. Connect the shield of the cable entering a device to that of the cable exiting the device. Do not connect the shield to any terminals labeled ground / GND or common / COM except when grounding the shield at one end only. Network termination The MS/TP network must be terminated at each end of the network segment. Termination involves connecting a ohm resistor between the + and - network terminals. Some devices are terminated by default (eg. Routers) and some have optional hardware or software termination settings. MVM configuration settings: When connecting the MVM into an exisiting BACnet network, the network settings must be assigned by or obtained from the building automation system contractor. The following information is required: 1. MAC Address a. Range: b. This address must be unique to each MVM or device within the physical network segment to which it is connected. 2. Device Instance a. Range: 0-4,194,303 b. This address must be unique to each BACnet enabled device within the entire BACnet network. 3. BAUD rate a. Options: 9,600, 19,200, 38,400, 76,800 b. All devices on the same physical network segment must use the same BAUD rate. FIGURE 1: 2-WIRE NETWORK CONNECTIONS: Router/System Controller + Router/System Controller COM COM Device + - FIGURE 2: 3-WIRE NETWORK CONNECTIONS Device COM COM Device + Device COM COM Device + Device COM COM 10 Multi-Variable Monitor - Manual pricecriticalcontrols.com

13 MAINTENANCE Troubleshooting The following information is provided in the event the MVM does not appear to be functioning normally after installation. Problem Solution 1. BACnet MS/TP is based on a RS-485 network. It must be wired in a daisy chain configuration. A daisy chain means that there is only one main cable, and every network device is connected directly along its path. Do not use Star, Bus, "T" or any other type of network configuration. Any of these other network configurations will result in an unreliable network and will make troubleshooting difficult. BACnet Communication Errors Correct polarity is imperative on MS/TP wiring. Always ensure that the positive terminal on a device has the same color wire connected to it throughout the network, same for the negative terminal. Eg. Two wire conductor with black and white wire - black to the positive terminal, and white to the negative terminal. Keep this consistent throughout the network. 2. The network should be terminated twice, once at the beginning, and again at the end of each run. This is strongly recommended. The network speed or baud rate must be the same throughout the network. NOTE: The default speed for Price BACnet MS/TP controls is 76,800. BACnet MS/TP currently supports 4 standard speeds which are: 9,600, 19,200, 38,400, 76, Binary address must be unique for each device on the network. No two devices can have the same address. This includes if you are incorporating a Price product into an existing network. Determine the existing addressing scheme for the existing network. The address is set using the Network service menu. 4. Ensure all connected devices are programmed with the predetermined device instances and mac addresses. If devices are not addressed correctly then they will not display on the MVM or will display in the incorrect location. MVM screen not clearly visible (Dim) Adjust the brightness setting in the Info section of the Setup Menu. pricecriticalcontrols.com Multi-Variable Monitor - Manual 11

14 NOTES 12 Multi-Variable Monitor - Manual pricecriticalcontrols.com

15 NOTES pricecriticalcontrols.com Multi-Variable Monitor - Manual 13

16 This document contains the most current product information as of this printing. For the most up-to-date product information, please go to pricecriticalcontrols.com 2018 Price Industries Limited. All rights reserved.

MVM MULTI-VARIABLE MONITOR

MVM MULTI-VARIABLE MONITOR MULTI-VARIABLE MONITOR The (MVM) is a highly adaptable touchscreen interface designed to display critical information of each room. The MVM is configurable as a remote station to monitor multiple rooms

More information

MVM MULTI-VARIABLE MONITOR

MVM MULTI-VARIABLE MONITOR MULTI-VARIABLE MONITOR The Price (MVM) is a highly adaptable touchscreen interface designed to display critical information of each room. The MVM is configurable as a remote station to monitor multiple

More information

BACnet Flow Controller for Fan Filter Units

BACnet Flow Controller for Fan Filter Units MANUAL SERVICE + INSTALLATION BACnet Flow Controller for Fan Filter Units BFC Series v300 Issue Date: 08/23/17 2017 Price Industries Limited. All rights reserved. TABLE OF CONTENTS Product Overview General

More information

Carbon Monoxide Sensor - ModBus

Carbon Monoxide Sensor - ModBus Introduction The CO Sensor uses an electrochemical sensor to monitor CO level in a range of 0 to 500 ppm and communicates via an RS-485 network configured for ModBus protocol. Before Installation Read

More information

RS-485 FClink Networking Room Thermostats with LCD for Fan Coil Units

RS-485 FClink Networking Room Thermostats with LCD for Fan Coil Units NT10 Series Revision Date April 16, 2014 RS-485 FClink Networking Room Thermostats with LCD for Fan Coil Units Features Ultra slim wall-mount unit to match any decor Supports standalone operation on RS

More information

installation Operation ADDRESS product diagram H8030/8031 INSTALLATION GUIDE

installation Operation ADDRESS product diagram H8030/8031 INSTALLATION GUIDE POWER MONITORING INSTALLATION GUIDE H8030/8031 H8030/8031 Modbus Energy Meter Networked kw/kwh Transducer Product Identification Model Max Amps CT Size Enhanced Data Stream Meters H8030-0100- 100 H8030-0300-

More information

IQ4NC Controllers. Data Sheet. Features. Description. Physical

IQ4NC Controllers. Data Sheet. Features. Description. Physical Data Sheet Controllers Controllers Description The enables Trend networks on different media (either, Trend current loop, or ) to be joined together in various configurations. It provides 4 virtual CNCs

More information

IQ4NC Controllers. Data Sheet. Features. Description. Physical

IQ4NC Controllers. Data Sheet. Features. Description. Physical Controllers Controllers Description The enables Trend networks on different media (either, Trend current loop, or ) to be joined together in various configurations. It provides 4 virtual CNCs which allow

More information

BACnet vs. Lonworks Specifications (Network Guide)

BACnet vs. Lonworks Specifications (Network Guide) Connections IP, MS/TP, Ethernet TCP/IP with Fox connections Topology BACnet p. 17-19 Lon pp. 39-40 Termination Requirements BACnet pp. 17-19 Lon pp. 39-40 Cable Requirements BACnet p. 16 Lon p. 41 Daisy

More information

clarity 3 Programmable Controller

clarity 3 Programmable Controller clarity 3 Programmable Controller BACnet General Purpose Controllers (B-AAC) DESCRIPTION Taco Clarity 3 FPC series controllers are designed to control building systems and HVAC equipment. The integrated

More information

Enercept H8035/H8036 Modbus Energy Meter Networked kw/kwh Transducers

Enercept H8035/H8036 Modbus Energy Meter Networked kw/kwh Transducers POWER MONITORING INSTALLATION GUIDE Enercept H8035/H8036 Modbus Energy Meter Networked kw/kwh Transducers US Patent No. 6,373,238 Installer's Specifications Input Voltage 208 to 480 VAC Number of Phases

More information

BACnet MS/TP Interface User s Guide

BACnet MS/TP Interface User s Guide PoolPak MPK with CommandPak Control System CPCS BACnet MS/TP Interface User s Guide DOCUMENT #: SVW07-BACNET-MSTP-20171020 UPDATED: OCTOBER 2017 INTRODUCTION PoolPak dehumidifiers equipped with an CommandPak

More information

INSTALLATION DKM-409 NETWORK ANALYSER WITH HARMONIC MEASUREMENT AND SCOPEMETER. Before installation:

INSTALLATION DKM-409 NETWORK ANALYSER WITH HARMONIC MEASUREMENT AND SCOPEMETER. Before installation: DKM-409 NETWORK ANALYSER WITH HARMONIC MEASUREMENT AND SCOPEMETER The DKM-409 is a precision instrument designed for displaying various AC parameters in 3-phase distribution panels. Thanks to its isolated

More information

BACnet. b3810 Series Local Controllers

BACnet. b3810 Series Local Controllers BACnet b380 Series Local Controllers The Andover Continuum TM b380 series controllers are designed for control of Air Handling Units, Roof Top Units, and other mechanical plant equipment. 0 Features Choose

More information

PLEASE READ INSTRUCTIONS CAREFULLY BEFORE INSTALLATION!

PLEASE READ INSTRUCTIONS CAREFULLY BEFORE INSTALLATION! TUC2 / TUCH2 Model Series Installation Instructions PLEASE READ INSTRUCTIONS CAREFULLY BEFORE INSTALLATION! APPLICATION The TUC2 provides temperature space monitoring with a backlit LCD. The TUCH2 provides

More information

QUICK SETUP GUIDE. BCM2 Series Branch Circuit Monitors. Safety Information. Equipment Maintenance and Service. Raritan DANGER!

QUICK SETUP GUIDE. BCM2 Series Branch Circuit Monitors. Safety Information. Equipment Maintenance and Service. Raritan DANGER! QUICK SETUP GUIDE BCM2 Series Branch Circuit Monitors Safety Information DANGER! HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Follow safe electrical work practices. See NFPA 70E in the USA, or applicable

More information

BCM2 Series Branch Circuit Monitors Quick Setup Guide

BCM2 Series Branch Circuit Monitors Quick Setup Guide BCM2 Series Branch Circuit Monitors Quick Setup Guide Safety Information DANGER! HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Follow safe electrical work practices. See NFPA 70E in the USA, or applicable

More information

MIC-2 MKII & MIC-2 MKII DIN, Multi-instrument DATA SHEET

MIC-2 MKII & MIC-2 MKII DIN, Multi-instrument DATA SHEET & DIN, Multi-instrument DATA SHEET Measurements All 3-phase AC measurements True RMS 4-Quadrant energy Power Quality Analysis Replaces analogue meters RS-485 Modbus RTU protocol TCP/IP Modbus (optional)

More information

AB0602D ARCHITECTURAL BALLAST DRIVER. Version Date 06/25/2012

AB0602D ARCHITECTURAL BALLAST DRIVER. Version Date 06/25/2012 AB0602D ARCHITECTURAL BALLAST DRIVER Version 0.10 Date 06/25/2012 Page 2 of 10 DESCRIPTION AND FEATURES The AB-0602D is a 6 circuit, 2400 Watts per circuit ballast driver intended for dimmable fluorescent

More information

Product Manual SZ2141

Product Manual SZ2141 Product Manual SZ11 Refrigeration Controller Communicating Controls Description The SZ11 is a microprocessor-based refrigeration controller and alarm interface designed to control three coolers or freezers

More information

6222 Two Door Module Technical Operations Manual

6222 Two Door Module Technical Operations Manual 6222 Two Door Module Technical Operations Manual TABLE OF CONTENTS Specifications...3 Overview...4 Operations...5 Custom Access Mode...5 Standard Access Mode...5 Offline Access Mode...5 Offline Memory...5

More information

SE8000 Series BACnet Integration Terminal Equipment Controller. Commercial and Lodging HVAC Applications

SE8000 Series BACnet Integration Terminal Equipment Controller. Commercial and Lodging HVAC Applications BACnet Integration Terminal Equipment Controller Commercial and Lodging HVAC Applications 2 SER8300 AND SE8300 SERIES PROTOCOL IMPLEMENTATION CONFORMANCE STATEMENT (PICS) Vendor Name: Schneider Electric

More information

MIC-2 MKII, Multi-instrument DATA SHEET

MIC-2 MKII, Multi-instrument DATA SHEET MIC-2 MKII, Multi-instrument DATA SHEET Measurements All 3-phase AC measurements True RMS 4-Quadrant energy Power Quality Analysis Replaces analogue meters RS-485 Modbus RTU protocol TCP/IP Modbus (optional)

More information

MicroTech III Applied Terminal Systems BACnet MS/TP Communication Module

MicroTech III Applied Terminal Systems BACnet MS/TP Communication Module Installation and Maintenance Manual IM 928-2 Group: Controls Part Number: 669207702 Date: March 2011 Supersedes: IM 928-1 MicroTech III Applied Terminal Systems BACnet MS/TP Communication Module NOTICE

More information

Networkable Dual Duct VAV Controller Specification and Installation Instructions

Networkable Dual Duct VAV Controller Specification and Installation Instructions Controller Models EVCBM14NIT2S (Master controller / 2 TRIACs) EVCS14N (Slave controller) TRL Series Thermostat TRL24 (Room Sensor: Temp) TRLH24 (Room Sensor: Temp and %RH) TRLG24 (Room Sensor: Temp and

More information

4. How to Connect the Fixture 3-Pin and 5-Pin XLR DMX Connectors:

4. How to Connect the Fixture 3-Pin and 5-Pin XLR DMX Connectors: TABLE OF CONTENTS 1. Safety Instructions 2. Technical Specifications 3. Installation 4. How to Connect the Fixture 5. DMX512 Configuration 6. DMX512 Connections 7. How to Set the Unit 8. Troubleshooting

More information

DWYER INSTRUMENTS, INC. Series AVUL Air Velocity Transmitter. Specifications - Installation and Operating Instructions.

DWYER INSTRUMENTS, INC. Series AVUL Air Velocity Transmitter. Specifications - Installation and Operating Instructions. Series AVUL Air Velocity Transmitter Specifications - Installation and Operating Instructions Bulletin P-AVUL 3-49/64 [95.71] 2-43/64 [67.92] 1/2 NPS 3-3/16 [80.81] 1-19/32 [40.59] 31/32 24.58 3-33/64

More information

QSNE-2DAL-D Energi Savr Node QSTM 20 V. DALI Loop 2. seetouch QS Wallstation Energi Savr Node QS. QS Control Link

QSNE-2DAL-D Energi Savr Node QSTM 20 V. DALI Loop 2. seetouch QS Wallstation Energi Savr Node QS. QS Control Link LUTRON R Node TM NE-2DAL-D Fixture Controller NE-2DAL-D 09.0.09 Node TM The Node is a DIN-rail mounted controller for -compliant Digital Addressable loads. It provides bus power and control for two independent

More information

Product Manual SZ2144

Product Manual SZ2144 Product Manual SZ1 Refrigeration Monitor Communicating Controls Description The SZ1 is a microprocessor-based refrigeration monitor and alarm interface designed to monitor up to six coolers or freezers.

More information

NT10 Series RS485 Modbus RTU Networking LCD Fan Coil Thermostat

NT10 Series RS485 Modbus RTU Networking LCD Fan Coil Thermostat Features Modern Appearance Stylish rotary dial and buttons Large LCD with backlight Support Modbus RTU protocol Support standalone operation on RS485 communication failure Retention of temperature set-point

More information

USER S MANUAL. DAS-G01 The Power of Tomorrow

USER S MANUAL. DAS-G01 The Power of Tomorrow USER S MANUAL DAS-G01 The Power of Tomorrow Richmond Heights 2018 0 USER S MANUAL DAS-G01 The Power of Tomorrow Richmond Heights 2018 Page 1 USER'S MANUAL TABLE OF CONTENTS Page # 1.0 GENERAL INFORMATION...

More information

BACnet MS/TP Gateways for Mega Controls Modbus RTU Networking Devices

BACnet MS/TP Gateways for Mega Controls Modbus RTU Networking Devices BMG Series Issue Date March 1, 2018 BACnet MS/TP Gateways for Mega Controls Modbus RTU Networking Devices General The BMG Series is a BACnet network gateway which routes communication traffic between BACnet

More information

BACnet Integration Manual September 1, 2010

BACnet Integration Manual September 1, 2010 PIR Ready VT7200 & VT7300 Series 24 Vac Fan Coil and Zoning Thermostats For Commercial and Lodging HVAC Applications BACnet Integration Manual September 1, 2010 1 VT7200X Series Product Overview The VT7200

More information

FX-2 Control Board ASY-360-XXX Setup and Configuration Guide

FX-2 Control Board ASY-360-XXX Setup and Configuration Guide FX-2 Control Board ASY-360-XXX Setup and Configuration Guide Micro Air Corporation Phone (609) 259-2636 124 Route 526. WWW.Microair.net Allentown NJ 08501 Fax (609) 259-6601 Table of Contents Introduction...

More information

SCC Inc. TS Series. Technical Instructions. Document No. TS-2000 March 15, 2016

SCC Inc. TS Series. Technical Instructions. Document No. TS-2000 March 15, 2016 SCC Inc. TS-MS Master Lead/Lag Panels for Boiler Management, and Building Management System Interface Technical Instructions March 15, 2016 Description A TS-MS Series Master Lead/Lag Panel sequences and

More information

EA500. Installation Instructions Transponder

EA500. Installation Instructions Transponder EA500 EN Installation Instructions Transponder EA500 Installation Instructions 1.0 Overview EN 2 1.0 Overview The EA500 Transponder is the Security Escort module that provides communications between the

More information

Installation and User Guide

Installation and User Guide D5 Installation and User Guide 8-Channel DALI Controller (478) Introduction The 478 is for controlling DALI ballasts, drivers and load interface units (except for the 490 Blinds Controller). Do not connect

More information

DTS 310. DIN Rail Mounted, Indoor Rated Revenue Grade Electrical Sub-meter. Page 1. Measurlogic MQ A

DTS 310. DIN Rail Mounted, Indoor Rated Revenue Grade Electrical Sub-meter. Page 1. Measurlogic MQ A DTS 310 DIN Rail Mounted, Indoor Rated Revenue Grade Electrical Sub-meter Page 1 1 PRODUCT OVERVIEW... 3 1.1 SUPPLIED ITEMS... 3 1.2 DOCUMENT CONVENTIONS... 4 1.3 PRODUCT SPECIFICATION... 4 1.3.1 Current

More information

NT50 Series RS485 Modbus RTU Networking LCD Fan Coil Thermostat

NT50 Series RS485 Modbus RTU Networking LCD Fan Coil Thermostat NT50 Series RS485 Modbus RTU Networking LCD Fan Coil Thermostat Features Modern Appearance Stylish rotary dial and buttons Large LCD with backlight Support Modbus RTU protocol Support standalone operation

More information

Carbon Monoxide (CO) Gas Detection and Control System

Carbon Monoxide (CO) Gas Detection and Control System Carbon Monoxide (CO) Gas Detection and Control System DESCRIPTION Gas monitor with built-in carbon monoxide (CO) sensor, wall-mounted, accepts inputs from remote devices such as other gas sensors, temperature

More information

C5S120 Installation and Connection Guide

C5S120 Installation and Connection Guide C5S120 Installation and Connection Guide Version: V1.1 1. Cautions Please note the following cautions. Mis-operation may lead to personal injury or equipment failure: 1) Do not energize the system before

More information

Multi-Point Gas Detection and Control System

Multi-Point Gas Detection and Control System Multi-Point Gas Detection and Control System Specifications subject to change without notice. USA 40804 Page of 7 DESCRIPTION Wall mounted, microprocessor-based, multi-point, analog electronic control

More information

Operation and Maintenance Manual

Operation and Maintenance Manual VM Series Operation and Maintenance Manual VM - Voltage Monitor VM-100-24 V VM-100-48 V VM-100-125 V VM-100-250 V EAGLE EYE POWER SOLUTIONS All Rights Reserved. 1 The Voltage Monitor series reads battery

More information

Multi-Point Gas Detection and Control System

Multi-Point Gas Detection and Control System Multi-Point Gas Detection and Control System DESCRIPTION Wall mounted, microprocessor-based, multi-point, analog electronic control system for various gas, temperature and humidity detection, control and

More information

BACnet MS/TP CONTINUE

BACnet MS/TP CONTINUE BACNET MS/TP Topics: 1 Network Requirements 2 Device Addressing 3 Power Supply Requirements 4 System Architecture 5 BACnet Objects & Services 6 Labwork 1 EST: 45:00 BACnet MS/TP 1 Network Requirements

More information

PM Series Power Meter

PM Series Power Meter PM Series Power Meter Quick Setup Guide - PMC-1000, PMC- 1001, PMM-1000, PMB-1960 Safety Information DANGER! HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Follow safe electrical work practices. See

More information

MIC-2 Multi-instrument DATA SHEET

MIC-2 Multi-instrument DATA SHEET Measurements All 3-phase AC measurements True RMS 4-Quadrant energy Power Quality Analysis Replaces analogue meters RS-485 Modbus RTU protocol TCP/IP Modbus (optional) Profibus DP (optional) I/O modules

More information

Suprex RS-485 SPX-7500 Wired Reader-Extender

Suprex RS-485 SPX-7500 Wired Reader-Extender Suprex RS-485 SPX-7500 Wired Reader-Extender Product Manual SPX-7500_MAN_181206 Cypress Integration Solutions 35 Years of Access Control Ingenuity CypressIntegration.com 2018 Cypress Computer Systems 1778

More information

Site Preparation. for AE250 Inverter Installation Guide. SolarVu

Site Preparation. for AE250 Inverter Installation Guide. SolarVu 5 Data 6 7 8 9 Site Preparation SolarVu for AE50 Inverter Installation Guide SolarVu is an energy portal that enables remote monitoring of renewable energy generation sites over the web. It requires the

More information

MicroTech III Water Source Heat Pump BACnet MS/TP Communication Module

MicroTech III Water Source Heat Pump BACnet MS/TP Communication Module Installation and Maintenance Manual IM 928- Group: Controls Part Number: 66920770 Date: July 2009 Supersedes: IM 928 MicroTech III Water Source Heat Pump BACnet MS/TP Communication Module NOTICE Use this

More information

RS-485 Modbus RTU Networking Room Thermostats with LCD for Fan Coil Units

RS-485 Modbus RTU Networking Room Thermostats with LCD for Fan Coil Units NT10 Series Issue Date February 21, 2016 RS-485 Modbus RTU Networking Room Thermostats with LCD for Fan Coil Units Features Ultra slim wall-mount unit to match any decor Supports standalone operation on

More information

QUICK SETUP GUIDE PMC-1000, PMC-1001, PMM-1000, PMB PM Series Power Meter. Safety Information. Equipment Maintenance and Service.

QUICK SETUP GUIDE PMC-1000, PMC-1001, PMM-1000, PMB PM Series Power Meter. Safety Information. Equipment Maintenance and Service. PM Series Power Meter QUICK SETUP GUIDE PMC-1000, PMC-1001, PMM-1000, PMB-1960 Safety Information DANGER! HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Follow safe electrical work practices. See NFPA

More information

Hotel Room Controller

Hotel Room Controller Full Service & Luxury Guest Room Management Solutions Delivering exceptional guest satisfaction while optimizing energy and operational efficiency Product at a Glance The (HRC) is at the heart of our Full

More information

F-3100 FLOW METER NETWORK INTERFACE Installation and Operation Guide

F-3100 FLOW METER NETWORK INTERFACE Installation and Operation Guide MODBUS FLOW AND ENERGY MEASUREMENT F-3100 FLOW METER NETWORK INTERFACE Installation and Operation Guide 11451 Belcher Road South, Largo, FL 33773 USA Tel +1 (727) 447-6140 Fax +1 (727) 442-5699 0725-2

More information

XT-9100 Technical Bulletin

XT-9100 Technical Bulletin System 9100 Technical Manual 636.4 Technical Bulletins Section Technical Bulletin Issue Date 0896 XT-9100 Technical Bulletin XT-9100 Extension Module/XP-910x Expansion Modules Page 3 Introduction 3 SX

More information

Submittal Data Sheet intelligent Touch Manager DCM601A71

Submittal Data Sheet intelligent Touch Manager DCM601A71 For use with the following VRV Models: FXAQ, FXDQ, FXEQ, FXFQ, FXHQ, FXLQ, FXMQ, FXMQ_MF, FXNQ, FXTQ, FXUQ, FXZQ, VAM For use with the following Daikin SkyAir Models: FAQ, FBQ, FCQ, FHQ, FTQ Capacity:

More information

Connecting a Cisco Output Module

Connecting a Cisco Output Module CHAPTER 5 Overview The optional Cisco Output Module (Figure 5-1) is attached to a Cisco Physical Access Gateway or Cisco Reader Module to provide additional connections for up to 8 outputs, each of which

More information

Millennium Simplicity Elite Parameter Points and Quirks

Millennium Simplicity Elite Parameter Points and Quirks Millennium Simplicity Elite Parameter Points and Quirks How to access, view and change parameter settings Program Button Test Reset UP Alarms Change Data Address Down 1. Push the Program button once. The

More information

USB VGA KVM Console Extender w/ Serial & Audio Over Cat5 UTP ft

USB VGA KVM Console Extender w/ Serial & Audio Over Cat5 UTP ft USB VGA KVM Console Extender w/ Serial & Audio Over Cat5 UTP - 1000 ft Product ID: SV565UTPUSA The SV565UTPUSA USB VGA KVM Console Extender w/ Serial & Audio Over Cat5 UTP (1000 ft) lets you control a

More information

QUICK SETUP GUIDE. BCM2 Series Branch Circuit Monitors. Safety Information. Equipment Maintenance and Service. Product Overview. Raritan DANGER!

QUICK SETUP GUIDE. BCM2 Series Branch Circuit Monitors. Safety Information. Equipment Maintenance and Service. Product Overview. Raritan DANGER! QUICK SETUP GUIDE BCM2 Series Branch Circuit Monitors Safety Information DANGER! HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Follow safe electrical work practices. See NFPA 70E in the USA, or applicable

More information

Andover ContinuumTM. b3850 Series Terminal Controllers

Andover ContinuumTM. b3850 Series Terminal Controllers TM b3850 Series Terminal Controllers The TM b3850 series controllers are native BACnet controllers that communicate on an RS-485 field bus as Master devices using the MS/TP BACnet protocol. 02 Features

More information

Connecting a Cisco Input Module

Connecting a Cisco Input Module CHAPTER 4 Overview The optional Cisco Input Module (Figure 4-1) is attached to a Cisco Physical Access Gateway or Cisco Reader Module to provide additional connections for up to ten input devices. Each

More information

BACnet Fixed Function Thermostat

BACnet Fixed Function Thermostat BACnet Fixed Function Thermostat FOR FAN COIL/HEAT PUMP/CONVENTIONAL SYSTEMS INSTALLATION INSTRUCTIONS APPLICATION Honeywell s BACnet Fixed Function Thermostat, BACnet FF, is a configurable device with

More information

FUME HOOD CONTROLLER (FHC)

FUME HOOD CONTROLLER (FHC) CRITICAL CONTROLS - PRODUCT OVERVIEW FUME HOOD CONTROLLER (FHC) The FHC is designed to control face velocity on variable volume fume hoods with audible and visual indicating alarms. The Fume Hood Controller

More information

Multi-Point Gas Detection and Control System

Multi-Point Gas Detection and Control System Multi-Point Gas Detection and Control System Specifications subject to change without notice. USA 50729 Page of 9 DESCRIPTION Wall mounted, microprocessor-based, multi-point, analog electronic control

More information

BACnet Fixed Function Thermostat

BACnet Fixed Function Thermostat BACnet Fixed Function Thermostat FOR FAN COIL/HEAT PUMP/CONVENTIONAL SYSTEMS INSTALLATION INSTRUCTIONS APPLICATION Honeywell s BACnet Fixed Function Thermostat, BACnet FF, is a configurable device with

More information

TABLE OF CONTENTS INTRODUCTION. 3. Analog Input Analog Output Digital Input Digital Output OPERATIONAL DESCRIPITON.. 7 PROGRAMMING AND INITIAL SETUP.

TABLE OF CONTENTS INTRODUCTION. 3. Analog Input Analog Output Digital Input Digital Output OPERATIONAL DESCRIPITON.. 7 PROGRAMMING AND INITIAL SETUP. DIVERSIFIED HEAT TRANSFER SERIES 700 STEAM GENERATOR CONTROLLER INSTRUCTION MANUAL VISIT OUR WEBSITE AT SIGMACONTROLS.COM SERIES 700 DHT STEAM GENERATOR MANUAL 042514 2 TABLE OF CONTENTS INTRODUCTION.

More information

Magnitude TM Chiller Unit Controller BACnet Communication Module (MS/TP, IP, Ethernet)

Magnitude TM Chiller Unit Controller BACnet Communication Module (MS/TP, IP, Ethernet) Installation and Maintenance Manual IM 963 Group: Controls Part Number: IM 963 Date: April 2010 Supercedes: New Magnitude TM Chiller Unit Controller BACnet Communication Module (MS/TP, IP, Ethernet) Daikin

More information

rcc.1081 Installation Instructions

rcc.1081 Installation Instructions rcc.1081 Installation Instructions Table of Contents Introduction...1 Specifications...2 Mounting...3 Wiring...5 Wiring Method...7 BACnet Network Wiring...8 Setting BACnet Address...9 Setting the BACnet

More information

System Controls Suggested Specification

System Controls Suggested Specification 1. Description A. Rooftop Unit Controller The Rooftop Unit Controller shall come equipped with a proportional-integral (PI) controller for accurate temperature control. The rooftop unit controller shall

More information

Two Door Controller GEN-045

Two Door Controller GEN-045 Australian Owned, Designed and Manufactured Two Door Controller GEN-045 Genesis Electronics Australia Pty Ltd www.genesiselectronics.com.au Distributed by: Genesis reserves the right to change or modify

More information

CRAGG RAILCHARGER Instruction Manual for 10DTC-12V 20DTC-12V 30DTC-24V 40DTC-12V 60DTC-12V

CRAGG RAILCHARGER Instruction Manual for 10DTC-12V 20DTC-12V 30DTC-24V 40DTC-12V 60DTC-12V CRAGG RAILCHARGER for 10DTC-12V 20DTC-12V 30DTC-24V 40DTC-12V 60DTC-12V Contents 1 Warnings, Cautions, and Notes... 1 2 Description... 2 3 Features... 2 3.1 STANDARD FEATURES... 2 3.2 CHARGER REGULATION...

More information

TRANSDUCER T4311, T4411

TRANSDUCER T4311, T4411 TRANSDUCER T4311, T4411 Programmable temperature transducer for RTD Pt1000 sensor with serial output RS232 and RS485 Instruction manual Instruction Manual for use of transducer: T4311 (RS232), T4411 (RS485)

More information

SolarVu Installation Guide for Sungrow SG30KU Inverters

SolarVu Installation Guide for Sungrow SG30KU Inverters SolarVu Installation Guide for Sungrow SG30KU Inverters Introduction SolarVu is an energy portal that enables remote monitoring of renewable energy generation sites over the internet. It requires the installation

More information

BA/BS4S Temperature Sensor Installation & Operating Instructions

BA/BS4S Temperature Sensor Installation & Operating Instructions Product Overview and Identification The BAPI-Stat 4 room temperature sensor features a large format LCD and slider setpoint adjustment. Additional options include button override and communication jack.

More information

SERIES CMT CARBON MONOXIDE GAS TRANSMITTER

SERIES CMT CARBON MONOXIDE GAS TRANSMITTER SERIES CMT CARBON MONOXIDE GAS TRANSMITTER INSTALLATION OPERATION AND MAINTENANCE MANUAL DWYER INTRUMENTS, INC. PO BOX 373, MICHIGAN CITY, IN. 46360 USA PHONE: 800-872-9141 FAX: 219-872-9057 Web: www.dwyer-inst.com

More information

thanos RS485 Modbus Application Functions Multifunction Room Operating Unit Datasheet

thanos RS485 Modbus Application Functions Multifunction Room Operating Unit Datasheet thanos RS485 Modbus Multifunction Room Operating Unit Datasheet Subject to technical alteration Issue date: 16.09.2015 603591 Application The thanos touch screen room operating unit has integrated temperature

More information

MYRIAD QLC 4-CHANNEL MONITOR/CONTROLLER INSTRUCTION MANUAL

MYRIAD QLC 4-CHANNEL MONITOR/CONTROLLER INSTRUCTION MANUAL MYRIAD QLC 4-CHANNEL MONITOR/CONTROLLER INSTRUCTION MANUAL VISIT OUR WEBSITE SIGMACONTROLS.COM MYR QLC MANUAL 013114 2 TABLE OF CONTENTS INTRODUCTION 3 Ordering Information Specifications Features WIRING

More information

Tempco Instruction Manual

Tempco Instruction Manual Tempco Instruction Manual 1/16 DIN Solid State Temperature Controller Relay Output Solid State Output For Heating Model Numbers: TEC-901, TEC-902, TEC-905 Temperature controls in this series are designed

More information

INSTALLATION MANUAL. LC 200 Electronic Overload Guard. Software versione PW0501 R 0.3

INSTALLATION MANUAL. LC 200 Electronic Overload Guard. Software versione PW0501 R 0.3 INSTALLATION MANUAL LC 200 Electronic Overload Guard Software versione PW0501 R 0.3 CONTENTS MAIN FEATURES LC 200 TECHNICAL FEATURES Page 2 SYMBOLS Page 3 WARNINGS Page 3 IDENTIFICATION DATA PLATE Page

More information

NETAFIM WILL NOT ACCEPT RESPONSIBILITY FOR DAMAGE RESULTING FROM THE USE OF NETAFIM'S PRODUCTS OR THE USE OF THIS MANUAL.

NETAFIM WILL NOT ACCEPT RESPONSIBILITY FOR DAMAGE RESULTING FROM THE USE OF NETAFIM'S PRODUCTS OR THE USE OF THIS MANUAL. [Type text] COPYRIGHT 2011, NETAFIM NO PARTS OF THIS PUBLICATION MAY BE REPRODUCED, STORED IN AN AUTOMATED DATA FILE OR MADE PUBLIC IN ANY FORM OR BY ANY MEANS, WHETHER ELECTRONIC, MECHANICAL, BY PHOTOCOPYING,

More information

Rev CH Breaker Gateway Installation and Operation Manual

Rev CH Breaker Gateway Installation and Operation Manual 026-1710 Rev 1 05-15-07 CH Breaker Gateway Installation and Operation Manual 1640 Airport Road, Suite 104 Kennesaw, GA 31044 Phone: (770) 425-2724 Fax: (770) 425-9319 ALL RIGHTS RESERVED. The information

More information

H704-42(H)(E), H704-42/1(H)(E)

H704-42(H)(E), H704-42/1(H)(E) POWER MONITORING INSTALLATION GUIDE H704-42(H)(E), H704-42/1(H)(E) Branch Current Monitor DANGER NOTICE Installer's Specifications General: Operating Temp. Range 0 to 60 C (32 to 140 F) (

More information

Andover ContinuumTM Infinet II

Andover ContinuumTM Infinet II Andover ContinuumTM Infinet II The i80 Series controllers are designed for control of Air Handling Units, Roof Top Units, and other mechanical plant equipment. Features 0 Choose the i80 model with the

More information

isma-b-mg-ip User Manual Global Control 5 Sp. z o.o. Poland, Warsaw

isma-b-mg-ip User Manual Global Control 5 Sp. z o.o. Poland, Warsaw isma-b-mg-ip User Manual Global Control 5 Sp. z o.o. Poland, Warsaw www.gc5.pl Table of content 1 Introduction... 4 1.1 Revision history... 5 1.2 Safety rules... 5 1.3 Technical specifications... 6 1.4

More information

EasyIO FC20 User Reference v1.3. EasyIO FC 20 DDC User Reference V1.3

EasyIO FC20 User Reference v1.3. EasyIO FC 20 DDC User Reference V1.3 EasyIO FC 20 DDC User Reference V1.3 Document Change Log 1 st April 2013 Document created. 13 th July 2013 Software configurations added. 27 th Sept 2014 FC now support pulse input. 6 th June 2015 Serial

More information

2-Wire VTH1550CHW-2 User s Manual

2-Wire VTH1550CHW-2 User s Manual 2-Wire VTH1550CHW-2 User s Manual V1.0.0 Table of Contents 1 General Introduction... 4 1.1 Network... 4 1.2 Front Panel... 5 1.3 Rear Panel... 6 2 Installation... 7 2.1 Install Device... 7 2.1.1 Screw...

More information

Introduction. What is the UC Open controller? Specifications

Introduction. What is the UC Open controller? Specifications UC Open CARRIER CORPORATION 2017 A member of the United Technologies Corporation family Stock symbol UTX Catalog No. 11-808-464-01 2/24/2017 Verify that you have the most current version of this document

More information

Getting started with your DGH module:

Getting started with your DGH module: Getting started with your DGH module: This document contains step-by-step instructions to quickly connect and communicate with your new DGH modules. For most applications, new modules require a one-time

More information

RS-485 Modbus RTU Networking FCU Thermostats with 0(2)-10 VDC Fan Output

RS-485 Modbus RTU Networking FCU Thermostats with 0(2)-10 VDC Fan Output NTAF Series Issue Date March 1, 2018 RS-485 Modbus RTU Networking FCU Thermostats with 0(2)-10 VDC Fan Output Features Ultra slim wall-mount unit to match any décor Supports Modbus RTU protpcol Supports

More information

Multi-Point Digital Gas Detection and Control System

Multi-Point Digital Gas Detection and Control System Multi-Point Digital Gas Detection and Control System Specifications subject to change without notice. USA 80308 Page of 0 DESCRIPTION Wall mounted, microprocessor-based, multi-point, RS-85 digital communicating

More information

System-10 BTU Meter BACnet Network Interface Installation Guide

System-10 BTU Meter BACnet Network Interface Installation Guide BACnet System-10 BTU Meter BACnet Network Interface Installation Guide 0652-3 1500 North Belcher Road, Clearwater, FL 33765 Tel (727) 447-6140 Fax (727) 442-5699 www.onicon.com sales@onicon.com 04-12 System-10-BAC

More information

INSTALLATION. Lightning / Surge Protection Static Shock IO. All ports/case Max. Length of Combined Cont. to Cont. Bus Network.

INSTALLATION. Lightning / Surge Protection Static Shock IO. All ports/case Max. Length of Combined Cont. to Cont. Bus Network. INSTALLATION VANTAGECONTROLS.COM VANTAGE INSTALL GUIDES 1061 South 800 East Orem, Utah 84097 Telephone 801 229 2800 Fax 801 224 0355 InFusion Controller II MODEL: IC-36-II & IC-24-II Overview The InFusion

More information

T2314, T2414. Instruction Manual

T2314, T2414. Instruction Manual Atmospheric pressure transmitter T2314, T2414 with RS232 / RS485 serial output Instruction Manual Instruction Manual Device type Pressure Output Galvanic isolated output T2314 RS232 - T2414 RS485 Device

More information

Extruder Controls ExtruVision S

Extruder Controls ExtruVision S Extruder Controls ExtruVision S ExtruVision S - The compact system solution for controlling, visualization, and operating extrusion systems Combination of control panel BA Touch with 5.7'' monitor and

More information

Precision humidity/temperature sensing/control

Precision humidity/temperature sensing/control HUMIDITY/TEMPERATURE SENSOR BACnet or Modbus Communication NT Series Precision humidity/temperature sensing/control FEATURES: BACnet or Modbus communication Temperature and RH monitoring Room, Duct or

More information

Excel Web II COMMUNICATION INTERFACES

Excel Web II COMMUNICATION INTERFACES HONEYWELL EXCEL 5000 OPEN SYSTEM Excel Web II COMMUNICATION INTERFACES TABLE OF CONTENTS Trademark Information... 2 Applicable Product Literature... 2 RS485 Interfaces... 3 The RS485 Standard... 3 EIA

More information

Room unit with PPS2 interface

Room unit with PPS2 interface s 1 640 1640P01 Desigo RX Room unit with PPS2 interface For use with: QAX34.3 Equipment from the RXC, RXB, RXL and RXA (PPS2) ranges Desigo PX automation stations 1) Devices with a PPS2 interface Measurement

More information

SINGLE READER EXPANSION MODULE

SINGLE READER EXPANSION MODULE SINGLE READER EXPANSION MODULE INSTALLATION GUIDE A D C - A C X 1 TR- SINGLE READER EXPANSION MODULE The ADC-ACX1 Single Reader Expansion Module provides a solution for interfacing to a one Wiegand reader

More information

Installation Guide. Section 1 - Room... pg 03. Section 2 - Duct... pg 23. I-CDD3_Modbus Installation. Modbus Gas Transmitters I-CDD3 Series

Installation Guide. Section 1 - Room... pg 03. Section 2 - Duct... pg 23. I-CDD3_Modbus Installation. Modbus Gas Transmitters I-CDD3 Series Specifications subject to change without notice. USA 110707 Page 1 of 40 Modbus Gas Transmitters I-CDD3 Series Transmitters, Carbon Monoxide, IR, Wall or Duct Installation Guide July 2011 Section 1 - Room...

More information