1 wwwatoscom Table F7-/E Proportional directional valves tpe DPZO-T* two stage, with position transducer, ISO 0 sizes 0, 6 and 5 DPZO-T* are two stage proportional valves with position transducer on the main spool which provide both directional and non compensated flow control according to electronic reference signal Valve bod Main stage Spool Pilot valve Main stage position transducer MODEL CODE DPZO Piloted proportional directional valve T = with position transducer TE= as T plus integral analog electronics TES= as L plus integral digital electronics Communication interfaces (onl for TES) PS = RS serial BC = CANbus BP = PROFIBUS-DP Valve size: = 0; = 6; = 5 A B Spool overlapping in central position, see section = P, A, B, T with positive overlapping () = P positive overlapping (); A, B, T, negative overlapping Spool size:, 5, 9 see section Pressure reducing valve Integral electronics Communication connector Main connector DPZO-TE-5 DPZO-TES-PS-7 (dotted line) TES PS 7 L 5 / * / ** / * Configuration, see section 5 = external plus central position, spring centered 7 = position, spring centered Spool tpe (regulating characteristics): L = linear; S = progressive; D = differential-progressive (as S, but with P-A = Q, P-B = Q/) DL = differential-linear (as L, but with P-A = Q, P-B = Q/) V = differential - linear () Series number Snthetic fluids WG = water-glcol PE =phosphate ester draulic options, see section : B =solenoid, integral electronics and position transducer at side of port A of the main stage E =external pilot (through port X) D =internal drain Electronic options for -TE execution see section 7: F =fault signal I =current reference input and monitor ( 0 ma) Q =enable signal Z =enable, fault and monitor signal Electronic options for -TES execution see section 9: I =current reference input and monitor ( 0 ma) Z =double power suppl, enable, fault and monitor Special options for -TES execution see section 9: SF = additional closed loop force control, with two remote pressure transducers SL = additional closed loop force control with one remote load cell SP = additional closed loop pressure control with one remote pressure transducer C = current feedback interface for transducer(s) onl for options /SF, /SL, /SP Notes: () Overlapping = 0% of spool stroke for tpe S; 5% of spool stroke for tpe L () The spool tpe V is available onl in size 9 for additional closed loop pressure controls, see section The operate in association with electronic drivers, see section, which suppl the proportional valves with proper current to align valve regulation to the reference signal supplied to the electronic driver The are available in different executions: -T, with position transducers ; -TE, -TES as -T plus analog (TE) or digital (TES) integral electronics The -wa spool, sliding into a 5-chambers bod, is piloted b a proportional directional valve tpe DZO (see tab F60) and it is controlled in closed loop position b means of the LVDT transducer The pressure reducing valve with fixed setting ensures a costant piloting pressure The integral electronics ensures factor presetting, fine functionalit plus valve-to-valve interchangeabilit and simplified wiring and installation The electronic main connector is full interchangeable for TE and TES executions Standard 7 pin main connector is used for power suppl, analog input reference and monitor signals pin connector is used for options /Z and /S* The special /S* options add a closed loop control of pressure (/SP) or force (/SF and /SL) to the basic closed loop spool position one Following communication interfaces are available for the digital -TES execution: -PS, Serial communication interface The valve reference signal is provided with analogue commands -BC, CANopen interface -BP, PROFIBUS DP interface The valves with -BC and -BP interfaces can be integrated into a fieldbus communication network and thus digitall operated b the machine control unit The coils are full plastic encapsulated (insulation class ) and the valves have antivibration, antishock and weather-proof features Mounting surface: ISO 0 sizes 0, 6 and 5 Max flow respectivel up to 60 l/min, 0 l/min and 680 l/min with valve differential pressure Δp = 0 bar, see table Max pressure: 50 bar ELECTRONIC DRIVERS Valve model -T -TE -TES Drivers model Data sheet E-ME-T G0 E-RI-TE G00 E-RI-TES G0 Note: For power suppl and communication connector see section 6 F7
2 YDRAULIC CARACTERISTICS OF STANDARD SPOOL (based on mineral oil ISO VG 6 at 50 C) Standard spools - hdraulic smbols *7 *7 *5 *5 *5/B *5/B Valve model Spool overlapping Spool tpe and size Max flow: at Δp = 0 bar at Δp = 0 bar [l/min] DPZO-T*-, L5 S5 D5 DL :60 60:00 L 0 5 DPZO-T*-, S D L5 S5 D5 DL5 L5 0:80 5: :0 00:5 0:5 0: DPZO-T*-, S5 D5 DL :0 90:0 60:80 680:0 Specific spools - hdraulic smbols *7-V9 *7-D9 *7-D9 *7-L9 *7-L9 Valve model Spool overlapping Spool tpe and size Max flow: at Δp = 0 bar at Δp = 0 bar [l/min] DPZO-T*- DPZO-T*- DPZO-T*-,,, D9 V9 D9 L9 V9 D9 V9 00:60 60: :50 0: :0 680: Pressure limits [bar] ports P, A, B, X = 50; T = 50; Y = 0 Response time [ms] < 60 < 75 < 80 steresis [%] % Repeatabilit Thermal drift ±0,5% zero point displacement < % at ΔT = 0 C Notes: Above performance data refer to valves coupled with Atos electronic drivers, see section In case of long time shutdown of the hdraulic suppl to the pilot valve, the driver has to be switched off to avoid its overheating YDRAULIC OPTIONS Option /B Solenoid, integral electronics and position transducer at side of port A of the main stage Pilot and drain configuration -The pilot / drain configuration can be modified as shown in the table E080 section The valve s standard configuration provides internal pilot and external drain For different pilot / drain configuration select: Option /E External pilot (through port X) Option /D Internal drain 5 GENERAL NOTES DPZO-T* proportional valves are CE marked according to the applicable Directives (eg Immunit/Emission EMC Directive and Low Voltage Directive) Installation, wirings and start-up procedures must be performed according to the general prescriptions shown in table F00 and in the installation notes supplied with relevant components The electrical signals of the valve (eg monitor signals) must not be directl used to activate safet functions, like to switch-on/off the machine s safet components, as prescribed b the European standards (Safet requirements of fluid technolog sstems and components-hdraulics, EN-89) 6 CONNECTIONS FOR -T EXECUTION SOLENOID POWER SUPPLY CONNECTOR PIN Signal description SUPPLY SUPPLY GND PIN POSITION TRANSDUCER CONNECTOR Signal description OUTPUT SIGNAL SUPPLY -5 VDC SUPPLY +5 VDC GND 7 ANALOG INTEGRAL DRIVERS -TE - OPTIONS Standard driver execution provides on the 7 pin main connector: Power suppl - VDC must be appropriatel stabilized or rectified and filtered; a,5 A safet fuse is required in series to the driver power suppl Appl at least a 0000 μf/0 V capacitance to single phase rectifiers or a 700 μf/0 V capacitance to three phase rectifiers Reference input signal - analogue differential input with ±0 VDC nominal range (pin D,E), proportional to desired valve spool position Monitor output signal - analog output signal proportional to the actual valve s spool position with ±0 VDC nominal range Following options are available to adapt standard execution to special application requirements: 7 Option /F It provides a Fault output signal in place of the Monitor output signal, to indicate fault conditions of the driver (cable interruption of spool transducers or reference signal - for /I option): Fault presence corresponds to 0 VDC, normal working corresponds to VDC 7 Option /I It provides the 0 ma current reference and monitor signals instead of the standard ±0 VDC It is normall used in case of long distance between the machine control unit and the valve or where the reference signal can be affected b electrical noise; the valve functioning is disabled in case of reference signal cable breakage 7 Option /Q It provides the possibilit to enable or disable the valve functioning without cutting the power suppl (the valve functioning is disabled but the driver current output stage is still active) To enable the driver suppl a VDC on the enable input signal 7 Option /Z This option includes /F and /Q features, plus the Monitor output signal When the driver is disabled (0 VDC on Enable signal) Fault output is forced to 0 VDC 75 Possible combined options: /FI and /IZ
3 8 ANALOG INTEGRAL DRIVERS -TE - MAIN FUNCTIONS AND ELECTRONIC CONNECTIONS MAIN CONNECTOR 7 PIN - STANDARD REGULATIONS AND LED (remove the rear cover) PIN - OPTION /Z SCALE BIAS DIAGNOSTIC B: positive bias adjust B: negative bias adjust (onl for single solenoid valves) S: positive scale adjust S: negative scale adjust (onl for double solenoid valves) LED: OFF normal working; ON fault presence SPOOL POSITION SIGNAL (main stage) B B S S LED 8 ELECTRONIC CONNECTIONS - 7 & PIN MAIN CONNECTORS Standard 7pin /Z option pin SIGNAL TECNICAL SPECIFICATIONS NOTES A V+ Power suppl VDC for solenoid power stage and driver logic Input - power suppl B V0 Power suppl 0 VDC for solenoid power stage and driver logic Gnd - power suppl C () 7 AGND Ground - signal zero for MONITOR signal (for standard, /Z option) Input - analog signal ENABLE Enable ( VDC) or disable (0 VDC) the driver (for /Q and /Z options) Input - on/off signal D INPUT+ Reference analog differential input: ±0 VDC maximum range ( 0 ma for /I option) For single solenoid valves the reference input is 0 +0 VDC ( 0 ma for /I option) E 5 INPUT - For double solenoid valves the reference input is ±0 VDC ( 0 ma for /I option) Input - analog signal F () 6 MONITOR Monitor analog output: ±0 VDC maximum range ( 0 ma for /I option) Output - analog signal FAULT Fault (0V) or normal working (V) (for /F and /Z option) Output - on/off signal - 8 R_ENABLE Repeat Enable - output repetition of Enable input Output - on/off signal - 9 NC do not connect Output - on/off signal - 0 NC do not connect Output - on/off signal G PE EART Internall connected to the driver housing Notes: () with /Q option ENABLE signal replaces AGND on pin C; MONITOR signal is reffered to pin B () with /F option FAULT signal replaces MONITOR on pin F A minimum time of 50ms to 00ms have be considered between the driver energizing with the VDC power suppl and when the valve is read to operate During this time the current to the valve coils is switched to zero 9 DIGITAL INTEGRAL DRIVERS -TES - OPTIONS Standard driver execution provides on the 7 pin main connector: Power suppl - VDC must be appropriatel stabilized or rectified and filtered; a,5 A safet fuse is required in series to each driver power suppl Appl at least a 0000 μf/0 V capacitance to single phase rectifiers or a 700 μf/0 V capacitance to three phase rectifiers Reference input signal - analogue differential input with ±0VDC nominal range (pin D,E), proportional to desired valve spool position Monitor output signal - analog output signal proportional to the actual valve s spool position with ±0VDC nominal range Following options are available to adapt standard execution to application requirements: 9 Option /I It provides 0 ma current reference and monitor signals instead of the standard ±0 V It is normall used in case of long distance between the machine control unit and the valve or where the reference signal can be affected b electrical noise; the valve functioning is disabled in case of reference signal cable breakage 9 Option /Z It provides on a pin main connector the above standard features plus: Logic power suppl Option /Z provides separate power suppl for the solenoid (pin, ) and for the digital electronic circuits (pin 9, 0) Cutting solenoid power suppl allows to interrupt the valve functioning but keeping energized the digital electronics thus avoiding fault conditions of the machine fieldbus controller (eg for emergenc, as provided b the European Norms EN95- for components with safet class ) Enable Input Signal To enable the driver, suppl a VDC on pin referred to pin : when the Enable signal is set to zero the valve functioning is disabled (zero current to the solenoid) but the driver current output stage is still active This condition does not compl with European Norms EN95- Fault Output Signal Fault output signal indicates fault conditions of the driver (solenoid short circuits/not connected, reference signal cable broken for 0mA input, etc) Fault presence corresponds to 0 VDC, normal working corresponds to VDC (pin referred to pin ): Fault status is not affected b the Enable input signal 9 Options /SP, /SF and /SL These options add the closed loop control of pressure (/SP) or force (/SF and /SL) to the basic functions of proportional directional valves: a dedicated software alternates pressure (force) and valve s spool position controls depending on the actual hdraulic sstem conditions A dedicated connector is available for the additional transducers that are required to be interfaced to the valve s driver ( pressure transducer for /SP, pressure transducers for /SF or load cell for /SL) Main pin connector is the same as /Z option plus two analog signals specific for the pressure (force) control: one for reference (pin 7) and one for monitor (pin 8) For futher details please refer to the driver technical table G0, section 9 Options /C Options /CSP, /CSF and /CSL are available to connect pressure (force) transducers with 0mA current output signal 95 Possible combined options: /CSP, /CSF, /CSL, /CISP, /CISF, /CISL and /IZ F7
4 0 DIGITAL INTEGRAL DRIVERS -TES - MAIN FUNCTIONS AND ELECTRONIC CONNECTIONS MAIN CONNECTOR 7 PIN - STANDARD COMMUNICATION CONNECTOR SCALE BIAS RAMPS 5 PIN Serial (-PS) or CANopen (-BC) PIN - OPTION /Z, /SP, /SF and /SL CONNECTOR FOR REMOTE PRESSURE (FORCE) TRANDUCER (for /SP, /SF and /SL) LINEARIZATION FIELDBUS REFERENCE ENANCED DIAGNOSTIC SPOOL POSITION SIGNAL (main stage) 5 PIN reverse ke PROFIBUS DP (-BP) 0 ELECTRONIC CONNECTIONS - 7 & PIN MAIN CONNECTORS Standard 7pin Note: /Z option pin SIGNAL TECNICAL SPECIFICATIONS NOTES A V+ Power suppl VDC for solenoid power stage (and for driver logic on 7 pin connection) Input - power suppl B V0 Power suppl 0 VDC for solenoid power stage (and for driver logic on 7 pin connection) Gnd - power suppl - ENABLE Enable ( VDC) or disable (0 VDC) the driver Input - on/off signal D INPUT+ Reference analog input: ±0 VDC maximum range ( 0 ma for /I option) For single solenoid valves the reference input is 0 +0 VDC ( 0 ma for /I option) E - INPUT - For double solenoid valves the reference input is ±0 VDC ( 0 ma for /I option) standard: differential input; /Z option: common mode INPUT+ referred to AGND Input - analog signal C 5 AGND Ground - signal zero for MONITOR signal signal zero for INPUT+ signal (onl for /Z option) Gnd - analog signal F 6 MONITOR Monitor analog output: ±0 VDC maximum range ( 0 ma for /I option) Output - analog signal - 7 NC do not connect (pressure/force input for /SP, /SF and /SL options, see 9) - 8 NC do not connect (pressure/force monitor for /SP, /SF and /SL options, see 9) - 9 VL+ Power suppl VDC for driver logic Input - power suppl - 0 VL0 Power suppl 0 VDC for driver logic Gnd - power suppl - FAULT Fault (0V) or normal working (V) Output - on/off signal G PE EART Internall connected to the driver housing A minimum time of 00 to 500 ms have be considered between the driver energizing with the VDC power suppl and when the valve is read to operate During this time the current to the valve coils is switched to zero 0 ELECTRONIC CONNECTIONS - 5 PIN COMMUNICATION CONNECTORS -PS Serial -BC CANopen -BP PROFIBUS DP PIN SIGNAL TECNICAL SPECIFICATION SIGNAL TECNICAL SPECIFICATION SIGNAL TECNICAL SPECIFICATION NC do not connect CAN_SLD Shield +5V for termination NC do not connect NC do not connect LINE-A Bus line (high) RS_GND Signal zero data line CAN_GND Signal zero data line DGND data line and termination Signal zero RS_RX Valves receiving data line CAN_ Bus line (high) LINE-B Bus line (low) 5 RS_TX Valves transmitting data line CAN_L Bus line (low) SIELD SOFTWARE TOOLS The functional parameters of the digital valves, as the bias, scale, ramp and linearization of the regulation characteristic, can be easil set and optimized with graphic interface b using the Atos E-SW software and the relevant USB adapters, cable and terminators, see tab G500 Valves with fieldbus communication interface (-BC and -BP) can be completel managed b the machine control unit; it is required to implement in the machine control the standard communication as described in the user manuals supplied with the relevant programming software For detailed description of availabile fieldbus features, see tab G50 MAIN CARACTERISTICS OF PROPORTIONAL DIRECTIONAL VALVES Assembl position An position Subplate surface finishing Roughness index, flatness ratio 0,0/00 (ISO 0) Ambient temperature -0 C +70 C for -T execution; -0 C +60 C for -TE and -TES executions Fluid draulic oil as per DIN for other fluids see section Recommended viscosit 5 00 mm /s at 0 C (ISO VG 5 00) Fluid contamination class ISO 8/5 achieved with in line filters of 0 μm and β0 _>75 (recommended) Fluid temperature -0 C +60 C (standard and /WG seals) -0 C +80 C (/PE seals) Coil resistance R at 0 C, Ω Max solenoid current,6 A Max power 5 Watt Insulation class (80 ) Due to the occuring surface temperatures of the solenoid coils, the European standards ISO 7- and EN98 must be taken into account Protection degree (CEI EN-6059) IP65 for -T execution; IP65 67 for -TE and -TES executions, depending to the connector tpe (see sect 6 ) Dut factor Continuous rating (ED=00%)
5 DIAGRAMS (based on mineral oil ISO VG 6 at 50 C) Regulation diagrams DPZO-: = L5, DL5, L5, DL5 = S5, D5, S5, D5 DPZO-: = L5, DL5, L5, DL5 = S5, D5, S5, D5 5 = L, L 6 = S, D, S, D DPZO-: 7 = L5, DL5, L5, DL5 8 = S5, D5, S5, D5 Max flow [l/min] at Δp = 0 bar Max flow [l/min] at Δp = 0 bar 5 6 Reference signal [V] Reference signal [V] X = Threshold for bias activation depending to the valve tpe and amplifier tpe Note: draulic configuration vs reference signal: Reference signal 0 +0 V 0 ma P n A / B n T Reference signal 0-0 V ma P n B / A n T Max flow [l/min] at Δp = 0 bar = differential - regenerative spool D9 D9 spool tpe with a fourth position specific to regenerative circuit, performed b means of an additional external check valve Application example Reference signal [V] X = Threshold for bias activation depending to the valve tpe and amplifier tpe 9 Flow rate [% of max] 0 = linear - internal regenerative spool L9 L9 spool tpe with a fourth position specific to regenerative circuit internal to the valve = P - B = A - T = P - A = B - T 5 = P - B (regenerative) Max flow [l/min] at Δp = 0 bar F7
6 = differential - linear spool V9 V9 spool tpe specific for alternate P/Q controls in combination with option /SP of digital integral drivers, see tab G0 section Flow rate [% of max] Operating diagrams Flow /Δp diagram stated at 00% of spool stroke DPZO-: = spools L5, S5, D5, DL5, D9, V9 DPZO-: = spools L5, S5, D5, DL5, D9, L9, V9 = spool L, S, D DPZO-: = spools L5, S5, D5, DL5, D9, V9 Flow rate [l/min] Flow rate [l/min] Valve pressure drop Δp [bar] Valve pressure drop Δp [bar] 5 Dnamic response The response times in section have to be considered as average values For the valves with digital electronics the dnamics performances can be optimized b setting the internal software parameters 6 Operation as throttle valve Single solenoid valves (*5) can be used as simple throttle valves: Pmax = 50 bar DPZO-*- Max flow [l/min] 5-L5 5-L5 5-L Δp [bar]
7 9 INSTALLATION DIMENSIONS FOR DPZO- AND DPZO- [mm] DPZO-T(*)- (dotted line = double solenoid version) ISO 0: 005 DPZO-T- SP-666 Mounting surface: (see table P005) Fastening bolts: socket head screws M6x0 class 9 Tightening torque = 5 Nm Seals: 5 OR 050; OR 08 Diameter of ports A, B, P, T: Ø = mm; SP-5 Diameter of ports X, Y: Ø = 5 mm; Mass [kg] T TE, TES DPZO-*-5* 7,7 8, DPZO-*-7* 8,6 9, DPZO-TE- SP-Z-7P or SP-ZM-7P DPZO-TES-*- SP-Z-5P/BP (for -BP) SP-Z-5P (for -PS and -BC) SP-Z-7P or SP-ZM-7P SP-5 SP-5 x SP-5 SP-5 -TE EXECUTION = pin connector SP-Z-P for option /Z -TES EXECUTION x = pin connector SP-Z-P for options /SF, /SL, /SP, /Z = M8 connector SP-Z-P-M8/5 moulded on cable 5 mt lenght for pressure or force transducer (options /SL, /SP) M8 connector SP-Z-P-M8/- moulded with cables, mt lenght for pressure transducers (options /SF) NOTE: For option /B the proportional solenoid, the position transducer and the electronics (in case of execution -TE and -TES) are at side of port A of the main stage DPZO-T(*)- (dotted line = double solenoid version) ISO 0: 005 Mounting surface: (see table P005) DPZO-T- SP-666 Fastening bolts: socket head screws M0x50 class 9 Tightening torque = 70 Nm socket head screws M6x0 class 9 Tightening torque = 5 Nm Seals: OR 0; OR 09/70 Diameter of ports A, B, P, T: Ø = 0 mm; SP-5 Diameter of ports X, Y: Ø = 7 mm; Mass [kg] T TE, TES DPZO-*-5*,9, DPZO-*-7*,8, DPZO-TE- SP-Z-7P or SP-ZM-7P DPZO-TES-*- SP-Z-7P or SP-ZM-7P SP-Z-5P/BP (for -BP) SP-Z-5P (for -PS and -BC) SP-5 SP-5 x SP-5 SP-5 -TE EXECUTION = pin connector SP-Z-P for option /Z -TES EXECUTION = pin connector SP-Z-P for options /SF, /SL, /SP, /Z x = M8 connector SP-Z-P-M8/5 moulded on cable 5 mt lenght for pressure or force transducer (options /SL, /SP) M8 connector SP-Z-P-M8/- moulded with cables, mt lenght for pressure transducers (options /SF) NOTE: For option /B the proportional solenoid, the position transducer and the electronics (in case of execution -TE and -TES) are at side of port A of the main stage F7
8 0 INSTALLATION DIMENSIONS FOR DPZO- [mm] DPZO-T(*)- (dotted line = double solenoid version) DPZO-T- SP-666 SP-5 DPZO-TE- SP-Z-7P or SP-ZM-7P SP-5 SP-5 ISO 0: 005 Mounting surface: (see table P005) Fastening bolts: 6 socket head screws Mx50 class 9 Tightening torque = 5 Nm Seals: OR ; OR 056 Diameter of ports A, B, P, T: Ø = mm; Diameter of ports X, Y: Ø = 7 mm; -TE EXECUTION = pin connector SP-Z-P for option /Z DPZO-TES-*- SP-Z-7P or SP-ZM-7P SP-Z-5P/BP (for -BP) SP-Z-5P (for -PS and -BC) x SP-5 SP-5 Mass [kg] T DPZO-*-5* 7, DPZO-*-7* 8 -TES EXECUTION = pin connector SP-Z-P for options /SF, /SL, /SP, /Z x = M8 connector SP-Z-P-M8/5 moulded on cable 5 mt lenght for pressure or force transducer (options /SL, /SP) M8 connector SP-Z-P-M8/- moulded with cables, mt lenght for pressure transducers (options /SF) TE, TES NOTE: For option /B the proportional solenoid, the position transducer and the electronics (in case of execution -TE and -TES) are at side of port A of the main stage 7,5 8, 6 MODEL CODES OF POWER SUPPLY AND COMMUNICATION CONNECTORS (to be ordered separatel) VALVE VERSION CONNECTOR CODE SP-666 SP-5 SP-Z-7P SP-ZM-7P SP-Z-P SP-Z-5P SP-Z-5P/BP PROTECTION DEGREE Power suppl Transducer IP65 connectors supplied with the valve -T -TE, -TES -TE/Z -TES /Z, /SF, /SL, /SP TES -PS, -BC TES -BP IP65 IP67 IP67 IP65 IP67 IP67 DATA SEET K500 G00, G0, K500 G0, K500 () M8 connector SP-Z-P-M8/5 moulded on cable 5 mt lenght for pressure or force transducer (options /SL, /SP) M8 connector SP-Z-P-M8/- moulded with cables, mt lenght for pressure transducers (options /SF) TES /SF, /SL, /SP SP-Z-P-M8/* () IP67 0/08
Proportional directional valves type DPZO-T* two stage, with position transducer, ISO 4401 sizes 10, 16 and 25
wwwatoscom Table F7-5/E Proportional directional valves tpe DPZO-T* two stage, with position transducer, ISO 0 sizes 0, 6 and 5 DPZO-T* are two stage proportional valves with position transducer on the
More informationProportional throttle cartridges type LIQZO-T*, 2-way with position transducer, ISO 7368 sizes from 16 to 50
www.atos.com Table F0-7/E Proportional throttle cartridges tpe LIQZO-T*, -wa with position transducer, ISO 768 sizes from 6 to 50 Poppet Sleeve Main stage position transducer Pilot valve Integral electronics
More informationProportional throttle cartridges type LIQZO-L*, 2-way high dynamics, with two position transducers, ISO 7368 sizes from 16 to 100
www.atos.com Table F00/E Proportional throttle cartridges tpe LIQZOL*, wa high dnamics, with two position transducers, ISO 768 sizes from 6 to 00 Poppet Sleeve Main stage position transducer Pilot valve
More informationProportional relief valves type RZMO-A* with Pmax 500 bar direct operated, without integral pressure transducer, ISO 4401 size 06
able TF035-1/E Proportional relief valves tpe 110106 RZMO-A* with Pmax 500 bar direct operated, without integral pressure transducer, ISO 4401 size 06 9 10 Valve bod Proportional solenoid Spring Poppet
More informationServoproportional valves type DLHZO and DLKZOR
www.atos.com Table F180-16/E Servoproportional valves type DLZO and DLKZOR sleeve execution, direct operated, with position transducer, ISO 01 size 06 and 10 Valve body Spool Sleeve Proportional solenoid
More informationProportional throttle cartridges type LIQZO-L*, 2-way high dynamics, with two position transducers, ISO 7368 sizes from 16 to 100
www.atos.com Table F00/E Proportional throttle cartridges tpe LIQZOL*, wa high dnamics, with two position transducers, ISO 768 sizes from 6 to Poppet Sleeve Main stage position transducer Pilot valve Integral
More informationProportional directional valves type DHZO-TES and DKZOR-TES direct operated, with position transducer, ISO 4401 size 06 and 10
www.atos.com Table F65-/E Proportional directional valves type DZO-TES and DKZOR-TES direct operated, with position transducer, ISO 440 size 06 and 0 TE and TES executions included in this table are available
More informationServoproportional valves type DLHZO-TE and DLKZOR-TE sleeve execution, direct operated, with position transducer, ISO 4401 size 06 and 10
www.atos.com Table F180-17/E Servoproportional valves type DLHZO-TE and DLKZOR-TE sleeve execution, direct operated, with position transducer, ISO 01 size 06 and 10 TE and TES executions included in this
More informationProportional throttle cartridges type LIQZO-L*, 3-way high dynamics, with two position transducers, sizes from 25 to 80
www.atos.com Table F07/E Proptional throttle cartridges tpe LIQZOL*, wa high dnamics, with two position transducers, sizes from 5 to 80 Poppet Sleeve Main stage position transducer Pilot valve Integral
More informationProportional throttle cartridges type LEQZO-A*, 2-way without position transducer, nominal sizes 16, 25 and 32
www.atos.com Table F310-5/E Proportional throttle cartridges type LEQZO-A*, 2-way without position transducer, nominal sizes 16, 25 and 32 Spool Cartridge Pilot valve Integral electronics Communication
More informationProportional relief valves type RZMO-A*
www.atos.com Table F007-9/E Proportional relief valves type RZMO-A* direct operated, without integral pressure transducer, ISO 440 size 06 Valve body Proportional solenoid Spring Poppet Integral electronics
More informationProportional relief valves type AGMZO-A* two stage, without integral pressure transducer, ISO 6264 size 10, 20 and 32
www.atos.com Table F035-19/E Proportional relief valves type AGMZO-A* two stage, without integral pressure transducer, ISO 6264 size 10, 20 and 32 Main poppet Pilot relief valve type RZMO Mechanical pilot
More informationProportional relief valves type RZMO-A* direct operated, without integral pressure transducer, ISO 4401 size 06
www.atos.com Table F007-20/E Proportional relief valves type RZMO-A* direct operated, without integral pressure transducer, ISO 440 size 06 Valve body Proportional solenoid Spring Poppet Integral electronics
More informationProportional relief valves type AGMZO-AES two stage, without integral pressure transducer, ISO 6264 size 10, 20 and 32
www.atos.com Table F035-20/E Proportional relief valves type AGMZO-AES two stage, without integral pressure transducer, ISO 6264 size 10, 20 and 32 1 MODEL CODE AGMZO Proportional pressure relief valve
More informationProportional reducing valves type AGRCZO-AES two stages, normally closed, without integral pressure transducer, ISO 5781 size 10 and 20
www.atos.com Table F050-8/E Proportional reducing valves type AGRCZO-AES two stages, normally closed, without integral pressure transducer, ISO 5781 size 10 and 20 Main poppet Pilot relief valve type RZMO
More informationProportional 2-way throttle cartridges high dynamics, with two position transducers, ISO 7368 sizes from 16 to 100
www.atos.com Table F0/E Proportional way throttle cartridges high dynamics, with two position transducers, ISO 768 sizes from 6 to LE and LES executions included in this table are available only for running
More informationSeals material: omit for NBR (mineral oil & water glycol) PE = FPM. Series number
www.atos.com Table F40-6/E Proportional flow valves type QVHZO-AES, QVKZOR-AES pressure compensated, direct operated, without position transducer, ISO 440 size 06 and 0 AES execution included in this table
More informationProportional electrohydraulic controls for PVPC pumps pressure-flow combined P/Q controls, analog or digital
www.atos.com Table A70/E Proportional electrohydraulic controls for PVPC pumps pressureflow combined P/Q controls, analog or digital The variable displacement axial piston pumps type PVPC, can be supplied
More informationProportional pressure valves with remote pressure transducer digital, closed loop high performances, rugged design
www.atos.com Table TFS100-1/E Proportional pressure valves with remote pressure transducer digital, closed loop high performances, rugged design T P RZMO-RES-N-NP-010 Proportional pressure relief and reducing
More informationHigh Performance proportional 2-way cartridges with two position transducers, ISO 7368 sizes from 16 to 100
www.atos.com Table F330-2/E High Performance proportional 2-way cartridges with two position transducers, ISO 7368 sizes from 6 to 00 Poppet Sleeve Main stage position transducer Pilot valve Integral electronics
More informationDigital electronic TES/LES drivers integral-to-valve format, for proportional valves with one or two spool position transducers
www.atos.com Table GS210-3/E Digital electronic TES/LES drivers integral-to-valve format, for proportional valves with one or two spool position transducers Scale Bias Linearization Ramps Real Time Fieldbus
More informationDigital electronic REB/RES drivers integral-to-valve format, for proportional valves with integral pressure transducer
Table GS205-1/E Digital electronic RE/RES drivers integral-to-valve format, for proportional valves with integral pressure transducer RE, RES RZMO- RE - P - NP Not Present Digital drivers supply and control,
More informationTWO CHANNELS REDUNDANT SAFETY ARCHITECTURE SINGLE CHANNEL NON-REDUNDANT SAFETY ARCHITECTURE
Table FY100-0/E Safety proportional valves with double power supply - option /U digital, direct or piloted operated, with one or two position transducers IEC 61508 Safety Integrity Level and ISO 13849
More informationProportional 2-way cartridges high performance digital, with two position transducers, ISO 7368 sizes from 16 to 100, rugged design
Table FS330-4/E Proportional 2-way cartridges high performance digital, with two position transducers, ISO 7368 sizes from 6 to, rugged design Poppet Sleeve Main stage position transducer Pilot valve Integral
More informationServoproportional 3-way cartridges digital, with two position transducers, sizes from 25 to 80, rugged design
Table FS340-3/E Servoproportional 3-way cartridges digital, with two position transducers, sizes from 2 to 80, rugged design Main Spool Sleeve Main stage position transducer Pilot valve Integral electronics
More informationProportional 2-way cartridges high performance rugged digital, with two position transducers, ISO 7368 sizes from 16 to 100
www.atos.com Table FS/E Proportional 2way cartridges high performance rugged digital, with two position transducers, ISO 7 sizes from to Poppet Sleeve Main stage position transducer Pilot valve Integral
More informationHydraulic Power Limitation. Real Time Fieldbus Reference. Enhanced Diagnostic. E-SW programming software. Set code (see note) Series number
www.atos.com Table G215obs/E Digital electronic drivers type E-RI-PES integral-to-valve format, for variable displacement axial piston pumps with alternate P/Q control obsolete components - availability
More informationTwo stage proportional directional valves high performance digital with two position transducers and positive spool overlap, rugged design
Table FS1753/E Two stage proportional directional valves high performance digital with two position transducers and positive spool overlap, rugged design Valve body Main stage Spool Pilot valve DPZOLESSNBP271
More informationProgramming tools for digital electronics Atos PC software, USB adapters, cables and terminators
www.atos.com Table GS00-/E Programming tools for digital electronics Atos PC software, adapters, cables and terminators POWER SUPPLY 4VDC direct PC connection POWER SUPPLY 4VDC adapter PC connection Programming
More informationProgramming tools for digital electronics Atos PC software, USB adapters, cables and terminators
www.atos.com Table GS00-0/E Programming tools for digital electronics Atos PC software, adapters, cables and terminators POWER SUPPLY 4VDC Programming software Personal Computer Isolator Cable Proportional
More informationISO cartridge valves type LID* Check function, ISO 7368 size from 16 to 100, high flow, Pmax 420 bar
Table H0409/E ISO cartridge valves type LID* Check function, ISO 78 size from to 00, high flow, Pmax 40 bar Functional cover Poppet Sleeve LIDO Spring Pilot operated check valve LIDR Directional control
More informationAnalog or Digital 08E001 RI-* drivers
www.atos.com Table T040obs/ Analog or igital 08001 RI-* drivers box format, for proportional valves with or without transducer(s) Scale Real-time ieldbus Reference ias nhanced iagnostic rey area: digital
More informationProgramming tools for digital electronics Atos PC software, USB adapters, cables and terminators
Atos spa - via alla Piana, 7 08 Sesto Calende - Varese - Italy COM BTH Table GS00-/E Programming tools for digital electronics Atos PC software, adapters, cables and terminators Digital electrohydraulic
More informationProportional controls for PVPC pumps analog pressure or flow, digital P/Q controls
Table S702/E Proportional controls for PVPC pumps analog pressure or flow, digital P/Q controls pump body proportional valve integral electronics with P/Q controller USB connector PVPCPESSPBC4046 swash
More informationDigital electropneumatic Positioner for the integrated mounting on process control valves
Digital electropneumatic Positioner for the integd mounting on process control valves Type 8692 can be combined with Compact stainless steel design Graphic display with backlight Easy start-up by automatic
More informationDigital electropneumatic Positioner for the integrated mounting on process control valves
Digital electropneumatic Positioner for the integrated mounting on process control valves Type 8692 can be combined with Compact stainless steel design Graphic display with backlight Easy start-up Comprehensive
More informationLFC Liquid Flow Controller
LFC Liquid Flow Controller Type 879 can be combined with High dynamic control through fast flow measurement Applicable for liquid dosing up to 600 ml/min (6 l/h) No moving parts in medium Fieldbus optional
More informationValve terminal RE-10 with Multi-pin, AS-Interface or bus connection 4 12 valve stations, 300 Nl/min (0.305 Cv)
Type of connection = AS = B1 = B6 Order code RE-10/08-M-1-060 Series Number of stations Multi-pin: 4, 6, 8, 10, 12 Bus versions: 4, 8, 12 Electrical options M-1 = Multi-pin D-Sub plug AS3 = AS-Interface
More informationInclination sensors 2-dimensional, measuring range up to ±90
Features Size 52 mm MEMS capacitive measuring principle EN13849 compliant firmware E1 compliant design Interface CANopen, SAE J1939, Analog Connection M12 and cable Protection up to IP 69K Optional GIM500R
More informationElectronic pressure switch with display Model PSD-4
Electronic pressure measurement Electronic pressure switch with display Model PSD-4 WIKA data sheet PE 81.86 Applications Machine tools Hydraulics and pneumatics Pumps and compressors Special-purpose machine
More informationD115 The Fast Optimal Servo Amplifier For Brush, Brushless, Voice Coil Servo Motors
D115 The Fast Optimal Servo Amplifier For Brush, Brushless, Voice Coil Servo Motors Ron Boe 5/15/2014 This user guide details the servo drives capabilities and physical interfaces. Users will be able to
More informationTECHNICAL DATASHEET Absolute Encoder AC 58 - Profibus
Diagnostic LED Cable or M12 connector Output of speed, acceleration Programmable: Resolution, Preset, Direction, Operation time Option: Display "tico" Address via interface parameterizable (optional) hubshaft
More informationDigital electropneumatic positioner
Digital electropneumatic positioner Type 879 can be combined with Compact metal housing Graphic display with backlight Easy start-up Comprehensive range of additional software functions Profibus DPV1 (optional)
More informationExpansion Module HZS 541-1S
Expansion Module HZS 541-1S 12.10.2015 Page 1 System Description The external HZS 541-1S expansion module provides users of biomass heating systems with additional 230 V AC relay outputs, analog inputs
More informationPower Amplifiers for PVH-EDC Pumps
Vickers Accessories Power Amplifiers for PVH-EDC Pumps EEA-EDC-436-A*-32 Design A1 - For use with PVH57 & 74 A2 - For use with PVH98 A3 - For use with PVH131 Panel Display General Description These amplifiers
More informationMass Flow Meter (MFM) for Gases
871 Mass Flow Meter (MFM for Gases Type 871 can be combined with Direct flow measurement for nominal flow rates from 1 ml N /min to 8 l N /min (N 2 in MEMS technology High accuracy Short response time
More informationicountpd Online Particle Detector
Online Particle Detector The icountpd from Parker represents the most up-to-date technology in solid particle detection. The design dynamics, attention to detail, and small size of the permanently mounted,
More informationDigital electropneumatic positioner
Digital electropneumatic positioner Type 879 can be combined with Compact metal housing Graphic display with backlight Easy start-up Comprehensive range of additional software functions Profibus DPV1 (optional)
More informationInstallation Manual Series PQ-L. Electronic Module. Bulletin /UK
Bulletin 5715-571 /UK Installation Manual Electronic Module Gutenbergstr. 38 41564 Kaarst, Germany Tel.: (+) 2131-513-0 Fax: (+) 2131-513-230 www.parker.com Copyright Ó 2000, Note This document and other
More informationRK-2 CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER WITH FLANGED HEAD
RK-2 CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER WITH FLANGED HEAD (ANALOG OR START/STOP OUTPUT) Main characteristics Absolute transducer Strokes from 50 to 4000mm (RK-2- -N/E/S) Digital output
More informationMiniAmp. Electronics & Software. Miniature Charge Amplifier. Type 5030A...
Electronics & Software MiniAmp Type 5030A... Miniature Charge Amplifier The MiniAmp Type 5030A is a single channel, industrial charge amplifier, which converts the charge signal from piezoelectric sensors
More informationControl Head for the integrated mounting on process valves
Control Head for the integrated mounting on process valves Type 8691 can be combined with Compact stainless steel design Integrated analogue valve position registration (Teach function) Coloured illuminated
More informationStandardized valve series MI-01 Connection pattern according to ISO 5599/1, size 1, 5/2- and 5/3-way NG and 1700 Nl/min (1.636 and 1.
Standardized valve series MI-01 Connection pattern according to ISO 5599/1, size 1, 5/2- and 5/3-way NG 9 1610 and 1700 Nl/min (1.636 and 1.728 Cv) Order code Series and function 1) Plug socket see page
More informationFlowtronic D 607 Series
Flowtronic D 607 Series Proportional Technology www.asco.com FLOW CONTROL: 607 SERIES FLOWTRONIC D Flowtronic D Flowtronic D is a digitally operated flow controller up to 70 SCFM (2000 Nl/min). The Flowtronic
More informationTM7NCOM16A CANopen interface block - IP67-16 I/O - M12
Characteristics CANopen interface block - IP67-16 I/O - M12 Main Range of product Product or component type Range compatibility Enclosure material Bus type [Ue] rated operational voltage Input/Output number
More informationPneumatic Control Unit for the integrated mounting on process valves
Pneumatic Control Unit for the integrated mounting on process valves Type 890 can be combined with Compact design Pilot valve with high air flow rate Internal control air channel Optical position indicator
More informationControl Head for the integrated mounting on process valves
Control Head for the integrated mounting on process valves Type can be combined with Compact stainless steel design Integrated analogue valve position registration (Teach function) Coloured illuminated
More informationB&R X67_IO_System_V3.14_E. X67 - System
B&R X67_IO_System_V3.14_E X67 - System X67 I/O System - Benefits to the User Why I/Os in the IP67? Potential of the remote machine concept Cost reduction with remote I/O concept Reduced wiring Minimization
More information14 Pressure Measurement. Measuring Devices Description Pressure range Connection Device Page
Measuring Devices Pressure range Connection Device Page Digital display mounting, für niedrige Drücke 0 2. mbar / 2. bar 4 mm tube MPV, MPA.02 portable, hand-operated 0 1 mbar / 10 bar 4 mm tube MHA.03
More informationMating connectors and cable sets for valves and sensors in hydraulics
s and cable sets for valves and sensors in hydraulics RE 08006 Edition: 06-04 Replaces: 0. Features s and cable sets for electrical connection of: - Valve solenoids - Valves with integrated electronics
More informationTemperature Switches
ETS 00 Series Temperature Switch for Inline and Tank Mounting Applications Description The ETS 00 is a compact electronic temperature switch with 4-digit digital display. Pressure resistant to 8700 psi,
More informationTECHNICAL DATASHEET #TDAX023300
Preliminary TECHNICAL DATASHEET #TDAX023300 2 Universal Inputs, Dual Universal Valve Controller 2 Universal Inputs 2-3A Outputs CAN (SAE J1939) Configurable with Electronic Assistant P/N: AX023300 Features
More informationMultipole and Fieldbus
> Series 3 Plug-In valve islands Valve Islands > 016 Series 3 Plug-In valve islands, Multipole and Fieldbus New versions Plug-In system for Series 3 solenoid valves, G1/8 port. Valve functions: x3/, 5/
More informationDigital electropneumatic Positioner for the integrated mounting on process control valves
Digital electropneumatic Positioner for the integrated mounting on process s Type 8694 can be combined with Digital smart positioner Automatic teach function Contact-free position sensor Compact stainless
More informationInclination sensors 1-dimensional, measuring range
Features Size 52 mm MEMS capacitive measuring principle EN13849 compliant firmware E1 compliant design Interface CANopen, SAE J1939, Analog Connection M12 and cable Protection up to IP 69K Optional GIM500R
More informationLighting Controls and Connectivity scenecom. scenecom L, XL, XL EM and XL EM Bac scenecom Controller
L, XL, XL EM and XL EM Bac Controller Product description Independent lighting control for up to 192 DALI control gears on 3 DALI lines Simple setup via WEB interface Cross DALI line control Freel programmable
More informationCPX-Terminal. Brief description. CPX analogue I/O modules CPX-4AE CPX-2AA. English e [ ]
CPX-Terminal Brief description CPX analogue I/O modules CPX-2AE CPX-4AE CPX-2AA English 8080173 2017-11e [8080175] Translation of the original instructions Documentation on the product For all available
More informationATV32HU11M2437 variable speed drive ATV32-1.1kW 200V - 1P - Bluetooth built-in - w heat sink
Characteristics variable speed drive ATV32-1.1kW 200V - 1P - Bluetooth built-in - w heat sink Main Range of product Altivar 32 Product or component type Product destination Product specific application
More informationExtruder Controls ExtruVision S
Extruder Controls ExtruVision S ExtruVision S - The compact system solution for controlling, visualization, and operating extrusion systems Combination of control panel BA Touch with 5.7'' monitor and
More informationControl Head for the integrated mounting on process valves
Control Head for the integrated mounting on process valves Type 8695 can be combined with Compact stainless steel design Integrated analog valve position registration (Teach function) Coloured illuminated
More informationSafety System CES-FD. Non-contact safety system CES-FD- Direct connection to decentralized peripheral systems (e.g. ET200pro) PLC
Non-contact safety system CES-FD- Evaluation of signals in the field Connection of CES read heads Connection to the ET200s and ET200pro Familiar EUCHNER AP interface Functional description Field evaluation
More informationElectric Actuators Type 5824 (without fail-safe action) Type 5825 (with fail-safe action)
Electric Actuators Type 5824 (without fail-safe action) Type 5825 (with fail-safe action) Application Electric actuators designed for valves used in heating, ventilation and air-conditioning systems as
More informationFlow measurement FlexFlow PF20S Flow sensor for industrial applications
Product highlights Parallel measurement of flow and temperature Flow measurement independent of the mounting position Large measuring range up to 400 cm/s Measurement at high media temperatures up to 125
More informationEC centrifugal module - RadiPac
KG9-AR- ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-7467 Mulfingen Phone +49 8 8- Fax +49 8 8- info@de.ebmpapst.com www.ebmpapst.com Limited partnership Headquarters Mulfingen County court Stuttgart
More informationDigital electropneumatic Positioner for the integrated mounting on process
Digital electropneumatic Positioner for the integrated mounting on process control valves Compact, robust stainless Steel design Easy start-up by automatic X-Tune function Contact-free position sensor
More informationElectronic Control Unit RC
Industrial Hydraulics Electric Drives and Controls Linear Motion and Assembly Technologies Pneumatics Service Automation Mobile Hydraulics Electronic Control Unit RC RE 900/.0 /6 Replaces: 09.0 Series
More informationC-Flow Coriolis Mass Flow Meter
Coriolis Mass Flow Meter Application and Features For fluids (e.g. PU components, paints) and gases of high density Suitable for aggressive and contaminated media Measurement of mass flow, density, temperature
More informationFieldbus System. New. New. Series EX260 IP67. Drives up to 32 solenoids. Daisy-chain wiring communication. Compact 28mm
Fieldbus System (Output device for driving port solenoid valves) Compact 8mm (Actual size) Space-saving Installation Daisy-chain wiring communication New IP67 For units with D-sub connector, and when connected
More informationControl head for hygienic process valves
for hygienic process valves Type can be combined with... Universal attachment for hygienic process valves Contactless position measurement system with 3 switching points (Teach-In function) Coloured status
More informationEC centrifugal module - RadiPac
KG9-AS8- ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-7 Mulfingen Phone +9 798 8- Fax +9 798 8- info@de.ebmpapst.com www.ebmpapst.com Limited partnership Headquarters Mulfingen County court Stuttgart
More informationMINI MCR-SL-PT100-UI-200
Configurable temperature transducer for PT00 INTERFACE Data sheet 078_en_0 PHOENIX CONTACT 00-0-5 Description The MINI MCR-SL-PT00-UI-00... is a configurable -way isolated temperature transducer. It is
More informationStrain gauge Measuring Amplifier GSV-1A8. Instruction manual GSV-1A8, GSV-1A8USB, GSV-1A16USB
Strain gauge Measuring Amplifier GSV-1A8 Instruction manual GSV-1A8, GSV-1A8USB, GSV-1A16USB GSV-1A8USB SubD1 (front side) GSV-1A8USB M12 (front side) GSV-1A16USB (rear side) GSV-1A8USB K6D (front side)
More informationMINI MCR-SL-PT100-UI. Active resistance thermometer measuring transducer. Data sheet. 1 Description
Active resistance thermometer measuring transducer Data sheet 099_en_06 PHOENIX CONTACT 0-0- Description The 6. mm wide MINI MCR-SL-PT00-UI-... is a configurable, -way isolated temperature measuring transducer.
More informationCompact universal controllers
7 867 Compact universal controllers RWF55... The RWF55 is used mainly for controlling the temperature or pressure in oil- or gas-fired heating plants. If the relevant parameters are set, the RWF55 can
More informationEC axial fan - HyBlade
WG-HU- ebm-papst Mulfingen GmbH & Co. KG Bachmühle D- Mulfingen Phone +9 9 - Fax +9 9 - info@de.ebmpapst.com www.ebmpapst.com Limited partnership Headquarters Mulfingen County court Stuttgart HRA 59 General
More informationMINI MCR-SL-UI-2I. Configurable signal duplicator. Data sheet. 1 Description
Configurable signal duplicator Data sheet 102382_en_03 PHOENIX CONTACT 2012-05-02 1 Description The MINI MCR-SL-UI-2I(-SP)(-NC) configurable signal duplicator is used to electrically isolate, condition,
More information26360, Inline. Technical data. Ordering information See page 2. For connector plugs see page 2 and data sheets N/en /2 5/2.
66, 87 Inline / and 5/ directional control valves NG 6 and Operation: elektromagnetic Indirectly controlled soft seal spool valves Port size: G /4 and G / For single and double operated actuators Manual
More informationstandard, short, preferential, top
ipf electronic gmbh Kalver Straße 27 standard design short design preferential series top series standard, short, preferential, top norm sensing ranges, increased sensing ranges 1100 1 2 1100 norm sensing
More informationP/N: AX Distribute your control functions directly onto the valve.
TECHNICAL DATASHEET #TDAX022311 Dual Plug-In Valve Controller, CANopen 2-2.5A Outputs Programmable Distribute your control functions directly onto the valve. P/N: AX022311 Features: Configurable for 1
More informationRE 50220/ Type ABZMS-40. Component series 1X Maximum operating pressure 1 bar 1/10
Float switch with two switching contacts, two programmable switching outputs for temperature, alternatively one programmable switching output and one analog output with display and control unit E 50220/07.0
More informationSolenoid Valves PN16 for gas flow interception
s 7 684 INTELLIGAS Solenoid Valves PN16 for gas flow interception E... 2 way solenoid valves, threaded or flanged connections, brass or bronze body. 12V DC or 230V AC coil with manual reset. Normally Open
More informationRotary Measuring Technology
Multiturn Type 8 Profibus-DP Very compact (only 87.8 mm installation depth); Ideal for dynamic applications thanks to its non-contact multiturn stage Solid shaft or blind hollow shaft Long service life
More informationDigital electropneumatic Positioner for the integrated mounting on process control valves
Digital electropneumatic Positioner for the integrated mounting on process control valves Type 8696 can be combined with Digital smart positioner Automatic teach function Contact-free position sensor Compact
More informationDigital electropneumatic Positioner for the integrated mounting on process control valves
Digital electropneumatic Positioner for the integrated mounting on process s Type 8694 can be combined with Automatic teach function Contact-free position sensor Compact stainless steel design AS-Interface
More informationRK CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER (ANALOG OUTPUT OR START/STOP)
RK CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER (ANALOG OUTPUT OR START/STOP) Main characteristics Absolute transducer Strokes from 50 to 4000 (RK-_- -N/S) Digital output RS422 Start/Stop (RK-_-
More informationIK4A (with ONDA technology)
IK4A (with ONDA technology) CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER (ANALOG OUTPUT) Main characteristics ONDA technology Optimized mechanical structure Strokes from 50 to 4000 Wide range
More informationManual English. for the Devices of the MVK-MPNIO Safety Series MVK-MPNIO F DI16/8 Art. No and MVK-MPNIO F DI8/4 F DO4 Art. No.
Introduction For Your Safety Description Installation Startup Configuration Run Mode Maintenance and Cleaning Manual English for the Devices of the Series MVK-MPNIO F DI16/8 Art. No. 55560 and MVK-MPNIO
More informationPhotoelectrics Diffuse-reflective Type PA18C.D..., DC
Photoelectrics Diffuse-reflective Type PA18C.D..., DC Miniature sensor range Range: 1 m (Axial), 0.8 m (Radial) Sensitivity adjustment by potentiometer Modulated, red light 625 nm Supply voltage: to 30
More informationDigital electropneumatic positioner
Digital electropneumatic positioner Type 879 can be combined with Compact and robust design Easy to start using tune function Dynamic positioning system with no air consumption in controlled state Profibus
More informationPhotoelectrics Retro-reflective, Polarized Type PA18C.P..., DC
Photoelectrics Retro-reflective, Polarized Type PA18C.P..., DC Miniature sensor range Range: 5 m (axial), 4 m (radial) Sensitivity adjustment by potentiometer Modulated, red light 625 nm Supply voltage: