Proportional directional valves type DPZO-T* two stage, with position transducer, ISO 4401 sizes 10, 16 and 25

Size: px
Start display at page:

Download "Proportional directional valves type DPZO-T* two stage, with position transducer, ISO 4401 sizes 10, 16 and 25"

Transcription

1 wwwatoscom Table F7-5/E Proportional directional valves tpe DPZO-T* two stage, with position transducer, ISO 0 sizes 0, 6 and 5 DPZO-T* are two stage proportional valves with position transducer on the main spool which provide both directional and non compensated flow control according to electronic reference signal Valve bod Main stage Spool Pilot valve Main stage position transducer MODEL CODE DPZO Piloted proportional directional valve T = with position transducer TE= as T plus integral analog electronics TES= as T plus integral digital electronics Communication interfaces (onl for TES) PS = RS serial BC = CANbus BP = PROFIBUS-DP Valve size: = 0; = 6; = 5 A B Spool overlapping in central position, see section = P, A, B, T with positive overlapping () = P positive overlapping (); A, B, T, negative overlapping Spool size:, 5, 9 see section Pressure reducing valve Integral electronics Communication connector Main connector DPZO-TE-5 DPZO-TES-PS-7 (dotted line) TES PS 7 L 5 / * / ** / * Configuration, see section 5 = external plus central position, spring centered 7 = position, spring centered Spool tpe (regulating characteristics): L = linear; S = progressive; D = differential-progressive (as S, but with P-A = Q, P-B = Q/) DL = differential-linear (as L, but with P-A = Q, P-B = Q/) Q = linear spool, for alternate P/Q controls () V = differential-progressive, for alternate P/Q controls () Series number Snthetic fluids WG = water-glcol PE =phosphate ester draulic options, see section : B =solenoid, integral electronics and position transducer at side of port A of the main stage E =external pilot (through port X) D =internal drain Electronic options for -TE execution see section 7: F =fault signal I =current reference input and monitor ( 0 ma) Q =enable signal Z =enable, fault and monitor signal ( pin connector) Electronic options for -TES execution see section 9: I =current reference input and monitor ( 0 ma) Z =double power suppl, enable, fault and monitor signals ( pin connector) Special options for -TES execution see section 9: SF = additional closed loop force control, with two remote pressure transducers SL = additional closed loop force control with one remote load cell SP = additional closed loop pressure control with one remote pressure transducer C = current feedback interface for transducer(s) onl for options /SF, /SL, /SP Notes: () Overlapping = 0% of spool stroke for tpe S, D and Q; 0% of spool stroke for tpe L and DL () The spools tpe Q and V are used in combination with option /SP of digital integral drivers, see section and G The operate in association with electronic drivers, see section, which suppl the proportional valves with proper current to align valve regulation to the reference signal supplied to the electronic driver The are available in different executions: -T, with position transducers ; -TE, -TES as -T plus analog (TE) or digital (TES) integral electronics The -wa spool, sliding into a 5-chambers bod, is piloted b a proportional directional valve tpe DZO (see tab F60) and it is controlled in closed loop position b means of the LVDT transducer The pressure reducing valve with fixed setting ensures a costant piloting pressure The integral electronics ensures factor presetting, fine functionalit plus valve-to-valve interchangeabilit and simplified wiring and installation The electronic main connector is full interchangeable for TE and TES executions Standard 7 pin main connector is used for power suppl, analog input reference and monitor signals pin connector is used for options /Z and /S* The special /S* options add a closed loop control of pressure (/SP) or force (/SF and /SL) to the basic closed loop spool position one Following communication interfaces are available for the digital -TES execution: -PS, Serial communication interface The valve reference signal is provided with analogue commands -BC, CANopen interface -BP, PROFIBUS DP interface The valves with -BC and -BP interfaces can be integrated into a fieldbus communication network and thus digitall operated b the machine control unit The coils are full plastic encapsulated (insulation class ) and the valves have antivibration, antishock and weather-proof features Mounting surface: ISO 0 sizes 0, 6 and 5 Max flow respectivel up to 60 l/min, 0 l/min and 680 l/min with valve differential pressure Δp = 0 bar, see table Max pressure: 50 bar ELECTRONIC DRIVERS Valve model -T -TE -TES -TES / SF, SL, SP Drivers model Data sheet E-ME-T G0 E-RI-TE G00 E-RI-TES G0 E-RI-TES/SF, /SL, /SP G Note: For power suppl and communication connector see section 6 F7

2 YDRAULIC CARACTERISTICS OF STANDARD SPOOL (based on mineral oil ISO VG 6 at 50 C) Standard spools - hdraulic smbols *7 *7 *5 *5 *5/B *5/B Valve model Spool overlapping Spool tpe and size Max flow (): at Δp = 0 bar at Δp = 0 bar max permissible flow [l/min] DPZO-T*-, L5 S5 D5 DL :60 60:00 80:00 L DPZO-T*-, S D L5 S5 D5 DL5 L5 0:80 5:0 550: :0 00:5 0:5 0:50 60:60 680: DPZO-T*-, S5 D5 DL :0 90:0 60:80 680:0 50:8050:880 Specific spools - hdraulic smbols *7-V9 *7-D9 *7-D9 *7-L9 *7-L9 *7-Q5 Valve model Spool overlapping Spool tpe and size Max flow (): at Δp = 0 bar at Δp = 0 bar max permissible flow [l/min] DPZO-T*- DPZO-T*- DPZO-T*-,,, D9 Q5 V9 D9 L9 Q5 V9 D9 Q5 00: : : : : : : : : V9 Pressure limits [bar] ports P, A, B, X = 50; T = 50 (0 for option /D); Y = 0 Response time [ms] < 60 < 75 < 80 steresis [%] % Repeatabilit Thermal drift ±0,5% zero point displacement < % at ΔT = 0 C Notes: Above performance data refer to valves coupled with Atos electronic drivers, see section In case of long time shutdown of the hdraulic suppl to the pilot valve, the driver has to be switched off to avoid its overheating () For different Δp, the max flow is in accordance to the diagrams in section YDRAULIC OPTIONS Option /B Solenoid, integral electronics and position transducer at side of port A of the main stage Pilot and drain configuration -The pilot / drain configuration can be modified as shown in the table E080 section The valve s standard configuration provides internal pilot and external drain For different pilot / drain configuration select: Option /E External pilot (through port X) Option /D Internal drain 5 GENERAL NOTES DPZO-T* proportional valves are CE marked according to the applicable Directives (eg Immunit/Emission EMC Directive and Low Voltage Directive) Installation, wirings and start-up procedures must be performed according to the general prescriptions shown in table F00 and in the installation notes supplied with relevant components The electrical signals of the valve (eg monitor signals) must not be directl used to activate safet functions, like to switch-on/off the machine s safet components, as prescribed b the European standards (Safet requirements of fluid technolog sstems and components-hdraulics, EN-98) 6 CONNECTIONS FOR -T EXECUTION SOLENOID POWER SUPPLY CONNECTOR PIN Signal description SUPPLY SUPPLY GND PIN POSITION TRANSDUCER CONNECTOR Signal description OUTPUT SIGNAL SUPPLY -5 VDC SUPPLY +5 VDC GND 7 ANALOG INTEGRAL DRIVERS -TE - OPTIONS Standard driver execution provides on the 7 pin main connector: Power suppl - VDC must be appropriatel stabilized or rectified and filtered; a,5 A safet fuse is required in series to the driver power suppl Appl at least a 0000 μf/0 V capacitance to single phase rectifiers or a 700 μf/0 V capacitance to three phase rectifiers Reference input signal - analog differential input with ±0 VDC nominal range (pin D,E), proportional to desired valve spool position Monitor output signal - analog output signal proportional to the actual valve s spool position with ±0 VDC nominal range Following options are available to adapt standard execution to special application requirements: 7 Option /F It provides a Fault output signal in place of the Monitor output signal, to indicate fault conditions of the driver (cable interruption of spool transducers or reference signal - for /I option): Fault presence corresponds to 0 VDC, normal working corresponds to VDC 7 Option /I It provides the 0 ma current reference and monitor signals instead of the standard ±0 VDC It is normall used in case of long distance between the machine control unit and the valve or where the reference signal can be affected b electrical noise; the valve functioning is disabled in case of reference signal cable breakage 7 Option /Q It provides the possibilit to enable or disable the valve functioning without cutting the power suppl (the valve functioning is disabled but the driver current output stage is still active) To enable the driver suppl a VDC on the enable input signal 7 Option /Z This option includes /F and /Q features, plus the Monitor output signal When the driver is disabled (0 VDC on Enable signal) Fault output is forced to 0 VDC 75 Possible combined options: /FI and /IZ

3 8 ANALOG INTEGRAL DRIVERS -TE - MAIN FUNCTIONS AND ELECTRONIC CONNECTIONS MAIN CONNECTOR 7 PIN - STANDARD REGULATIONS AND LED (remove the rear cover) PIN - OPTION /Z SCALE CURRENT TO COIL S (Onl for double solenoid valves) BIAS DIAGNOSTIC B: positive bias adjust B: negative bias adjust (onl for single solenoid valves) S: positive scale adjust S: negative scale adjust (onl for double solenoid valves) LED: OFF normal working; ON fault presence SPOOL POSITION SIGNAL (main stage) B B S S LED 8 ELECTRONIC CONNECTIONS - 7 & PIN MAIN CONNECTORS Standard 7pin /Z option pin SIGNAL TECNICAL SPECIFICATIONS NOTES A V+ Power suppl VDC for solenoid power stage and driver logic Input - power suppl B V0 Power suppl 0 VDC for solenoid power stage and driver logic Gnd - power suppl C () 7 AGND Ground - signal zero for MONITOR signal (for standard, /Z option) Input - analog signal ENABLE Enable ( VDC) or disable (0 VDC) the driver (for /Q and /Z options) Input - on/off signal D INPUT+ Reference analog differential input: ±0 VDC maximum range ( 0 ma for /I option) For single solenoid valves the reference input is 0 +0 VDC ( 0 ma for /I option) E 5 INPUT - For double solenoid valves the reference input is ±0 VDC ( 0 ma for /I option) Input - analog signal F () 6 MONITOR Monitor analog output: ±0 VDC maximum range ( 0 ma for /I option) Output - analog signal FAULT Fault (0V) or normal working (V) (for /F and /Z option) Output - on/off signal - 8 R_ENABLE Repeat Enable - output repetition of Enable input Output - on/off signal - 9 NC do not connect Output - on/off signal - 0 NC do not connect Output - on/off signal G PE EART Internall connected to the driver housing Notes: () with /Q option ENABLE signal replaces AGND on pin C; MONITOR signal is reffered to pin B () with /F option FAULT signal replaces MONITOR on pin F A minimum time of 50ms to 00ms have be considered between the driver energizing with the VDC power suppl and when the valve is read to operate During this time the current to the valve coils is switched to zero 9 DIGITAL INTEGRAL DRIVERS -TES - OPTIONS Standard driver execution provides on the 7 pin main connector: Power suppl - VDC must be appropriatel stabilized or rectified and filtered; a,5 A safet fuse is required in series to each driver power suppl Appl at least a 0000 μf/0 V capacitance to single phase rectifiers or a 700 μf/0 V capacitance to three phase rectifiers Reference input signal - analog differential input with ±0VDC nominal range (pin D,E), proportional to desired valve spool position Monitor output signal - analog output signal proportional to the actual valve s spool position with ±0VDC nominal range Following options are available to adapt standard execution to application requirements: 9 Option /I It provides 0 ma current reference and monitor signals instead of the standard ±0 V It is normall used in case of long distance between the machine control unit and the valve or where the reference signal can be affected b electrical noise; the valve functioning is disabled in case of reference signal cable breakage 9 Option /Z It provides on a pin main connector the above standard features plus: Logic power suppl Option /Z provides separate power suppl for the solenoid (pin, ) and for the digital electronic circuits (pin 9, 0) Cutting solenoid power suppl allows to interrupt the valve functioning but keeping energized the digital electronics thus avoiding fault conditions of the machine fieldbus controller This condition allows to realize safet sstems in compliance with European Norms EN89- (ex EN95-) Enable Input Signal To enable the driver, suppl a VDC on pin referred to pin : when the Enable signal is set to zero the valve functioning is disabled (zero current to the solenoid) but the driver current output stage is still active This condition does not compl with European Norms EN89- (ex EN95-) Fault Output Signal Fault output signal indicates fault conditions of the driver (solenoid short circuits/not connected, reference signal cable broken for 0mA input, etc) Fault presence corresponds to 0 VDC, normal working corresponds to VDC (pin referred to pin ): Fault status is not affected b the Enable input signal 9 Options /SP, /SF and /SL These options add the closed loop control of pressure (/SP) or force (/SF and /SL) to the basic functions of proportional directional valves: a dedicated software alternates pressure (force) and valve s spool position controls depending on the actual hdraulic sstem conditions A dedicated connector is available for the additional transducers that are required to be interfaced to the valve s driver ( pressure transducer for /SP, pressure transducers for /SF or load cell for /SL) Main pin connector is the same as /Z option plus two analog signals specific for the pressure (force) control: one for reference (pin 7) and one for monitor (pin 8) For futher details please refer to the driver technical table G 9 Options /C Options /CSP, /CSF and /CSL are available to connect pressure (force) transducers with 0mA current output signal 95 Possible combined options: /ISF, /ISL, /ISP, /CSP, /CSF, /CSL, /CISP, /CISF, /CISL and /IZ F7

4 0 DIGITAL INTEGRAL DRIVERS -TES - MAIN FUNCTIONS AND ELECTRONIC CONNECTIONS MAIN CONNECTOR 7 PIN - STANDARD COMMUNICATION CONNECTOR SCALE BIAS RAMPS 5 PIN Serial (-PS) or CANopen (-BC) PIN - OPTION /Z, /SP, /SF and /SL CONNECTOR FOR REMOTE PRESSURE (FORCE) TRANDUCER (for /SP, /SF and /SL) LINEARIZATION FIELDBUS REFERENCE ENANCED DIAGNOSTIC SPOOL POSITION SIGNAL (main stage) 5 PIN reverse ke PROFIBUS DP (-BP) 0 ELECTRONIC CONNECTIONS - 7 & PIN MAIN CONNECTORS Standard 7pin Note: /Z option pin SIGNAL TECNICAL SPECIFICATIONS NOTES A V+ Power suppl VDC for solenoid power stage (and for driver logic on 7 pin connection) Input - power suppl B V0 Power suppl 0 VDC for solenoid power stage (and for driver logic on 7 pin connection) Gnd - power suppl - ENABLE Enable ( VDC) or disable (0 VDC) the driver Input - on/off signal D INPUT+ Reference analog input: ±0 VDC maximum range ( 0 ma for /I option) For single solenoid valves the reference input is 0 +0 VDC ( 0 ma for /I option) E - INPUT - For double solenoid valves the reference input is ±0 VDC ( 0 ma for /I option) standard: differential input; /Z option: common mode INPUT+ referred to AGND Input - analog signal C 5 AGND Ground - signal zero for MONITOR signal signal zero for INPUT+ signal (onl for /Z option) Gnd - analog signal F 6 MONITOR Monitor analog output: ±0 VDC maximum range ( 0 ma for /I option) Output - analog signal - 7 NC do not connect (pressure/force input for /SP, /SF and /SL options, see 9) - 8 NC do not connect (pressure/force monitor for /SP, /SF and /SL options, see 9) - 9 VL+ Power suppl VDC for driver logic Input - power suppl - 0 VL0 Power suppl 0 VDC for driver logic Gnd - power suppl - FAULT Fault (0V) or normal working (V) Output - on/off signal G PE EART Internall connected to the driver housing A minimum time of 00 to 500 ms have be considered between the driver energizing with the VDC power suppl and when the valve is read to operate During this time the current to the valve coils is switched to zero 0 ELECTRONIC CONNECTIONS - 5 PIN COMMUNICATION CONNECTORS -PS Serial -BC CANopen -BP PROFIBUS DP PIN SIGNAL TECNICAL SPECIFICATION SIGNAL TECNICAL SPECIFICATION SIGNAL TECNICAL SPECIFICATION NC do not connect CAN_SLD Shield +5V for termination NC do not connect NC do not connect LINE-A Bus line (high) RS_GND Signal zero data line CAN_GND Signal zero data line DGND data line and termination Signal zero RS_RX Valves receiving data line CAN_ Bus line (high) LINE-B Bus line (low) 5 RS_TX Valves transmitting data line CAN_L Bus line (low) SIELD SOFTWARE TOOLS The functional parameters of digital valves, as the bias, scale ramp and linearization of the regulation characteristic, can be easil set and optimized with the Atos E-SW programming software, available in three different versions according to the driver s communication interfacing: E-SW-PS (Serial), E-SW-BC (CANopen) and E-SW-BP (PROFIBUS DP) A proper connection is required between the PC and the electronic driver communication port: for a more detailed description of software interface, PC requirements, adapters, cables and terminators, please see table G500 Proportional valves with fieldbus communication interface (-BC and -BP) can be directl managed b the machine control unit; it is required to implement in the machine control the standard communication as described in the user manuals supplied with the relevant programming software For detailed description of available fieldbus feature, see table G50 On first suppl of the E-SW software, it is required to appl for the registration in the Atos download area: wwwdownloadatoscom Once the registration is completed, the password will be sent b The software remains active for 0 das from the installation date and then it stops until the user inputs his password With the password ou can also download, in our personal area, the latest releases of the Atos software, manuals, drivers and configuration files MAIN CARACTERISTICS OF PROPORTIONAL DIRECTIONAL VALVES Assembl position An position Subplate surface finishing Roughness index, flatness ratio 0,0/00 (ISO 0) Ambient temperature -0 C +70 C for -T execution; -0 C +60 C for -TE and -TES executions Fluid draulic oil as per DIN for other fluids see section Recommended viscosit 5 00 mm /s at 0 C (ISO VG 5 00) Fluid contamination class ISO 8/5 achieved with in line filters of 0 μm and β0 _>75 (recommended) Fluid temperature -0 C +60 C (standard and /WG seals) -0 C +80 C (/PE seals) Coil resistance R at 0 C, Ω Max solenoid current,6 A Max power 5 Watt Insulation class (80 ) Due to the occuring surface temperatures of the solenoid coils, the European standards ISO 7- and EN98 must be taken into account Protection degree (CEI EN-6059) IP65 for -T execution; IP65 67 for -TE and -TES executions, depending to the connector tpe (see sect 6 ) Dut factor Continuous rating (ED=00%)

5 DIAGRAMS (based on mineral oil ISO VG 6 at 50 C) Regulation diagrams DPZO-: = L5, DL5, L5, DL5 = S5, D5, S5, D5 DPZO-: = L5, DL5, L5, DL5 = S5, D5, S5, D5 5 = L, L 6 = S, D, S, D DPZO-: 7 = L5, DL5, L5, DL5 8 = S5, D5, S5, D5 Max flow [l/min] at Δp = 0 bar Max flow [l/min] at Δp = 0 bar 5 6 Reference signal [V] Reference signal [V] X = Threshold for bias activation depending to the valve tpe and amplifier tpe Note: draulic configuration vs reference signal: Reference signal 0 +0 V 0 ma P n A / B n T Reference signal 0-0 V ma P n B / A n T Max flow [l/min] at Δp = 0 bar = differential - regenerative spool D9 D9 spool tpe with a fourth position specific to regenerative circuit, performed b means of an additional external check valve Reference signal [V] X = Threshold for bias activation depending to the valve tpe and amplifier tpe 9 Flow rate [% of max] Application example 0 = linear - internal regenerative spool L9 L9 spool tpe with a fourth position specific to regenerative circuit internal to the valve = P - B = A - T = P - A = B - T 5 = P - B (regenerative) Max flow [l/min] at Δp = 0 bar F7

6 = linear spool Q5 Q5 spool tpe is specific for alternate P/Q controls in combination with /SP option of digital integral drivers, see tab G It allows to control the pressure in A port or B port and it provides a safet central position (A-T/B-T ) to depressurize the actuator chambers The strong meter-in characteristic makes the spool suitable for both pressure control and motion regulations in several applications Flow rate [% of max] = differential - progressive spool V9 V9 spool tpe is specific for alternate P/Q controls in combination with /SP option of digital integral drivers, see tab G This spool is speciall designed to manage the whole injection ccle in plastic machiner, thanks to the following specific features: - strong meter-in characteristic to allow the pressure control in A port during the holding pressure (P-A) and the plasticizing (A-T) phases - safet central position (A-T/B-T ) to depressurize the actuator chambers - large A-T and B-T flow capabilit, required during the plasticizing phase, to discharge big volumes from high differential injection clinders with low pressure drops and permitting the contemporar oil suction from tank Flow rate [% of max] Operating diagrams Flow /Δp diagram stated at 00% of spool stroke DPZO-: = spools L5, S5, D5, DL5, D9, V9 DPZO-: = spools L5, S5, D5, DL5, D9, L9, V9 = spool L, S, D DPZO-: = spools L5, S5, D5, DL5, D9, V9 Flow rate [l/min] Flow rate [l/min] Valve pressure drop Δp [bar] Valve pressure drop Δp [bar] Dnamic response The response times in section have to be considered as average values For the valves with digital electronics the dnamics performances can be optimized b setting the internal software parameters Operation as throttle valve Single solenoid valves (*5) can be used as simple throttle valves: Pmax = 50 bar DPZO-*- Max flow [l/min] 5-L5 5-L5 5-L Δp [bar] 0 0 0

7 INSTALLATION DIMENSIONS FOR DPZO- AND DPZO- [mm] DPZO-T(*)- (dotted line = double solenoid version) ISO 0: 005 DPZO-T- SP-666 Mounting surface: (see table P005) Fastening bolts: socket head screws M6x0 class 9 Tightening torque = 5 Nm Seals: 5 OR 050; OR 08 Diameter of ports A, B, P, T: Ø = mm; SP-5 Diameter of ports X, Y: Ø = 5 mm; Mass [kg] T TE, TES DPZO-*-5* 8,5 8,9 DPZO-*-7* 9, 9,8 DPZO-TE- SP-Z-7P or SP-ZM-7P DPZO-TES-*- SP-Z-5P/BP (for -BP) SP-Z-5P (for -PS and -BC) SP-Z-7P or SP-ZM-7P SP-5 SP-5 x SP-5 SP-5 -TE EXECUTION = pin connector SP-Z-P for option /Z -TES EXECUTION x = pin connector SP-Z-P for options /SF, /SL, /SP, /Z = M8 connector SP-Z-P-M8/5 moulded on cable 5 mt lenght for pressure or force transducer (options /SL, /SP) M8 connector SP-Z-P-M8/- moulded with cables, mt lenght for pressure transducers (options /SF) NOTE: For option /B the proportional solenoid, the position transducer and the electronics (in case of execution -TE and -TES) are at side of port A of the main stage DPZO-T(*)- (dotted line = double solenoid version) ISO 0: 005 Mounting surface: (see table P005) DPZO-T- SP-666 Fastening bolts: socket head screws M0x50 class 9 Tightening torque = 70 Nm socket head screws M6x0 class 9 Tightening torque = 5 Nm Seals: OR 0; OR 09/70 Diameter of ports A, B, P, T: Ø = 0 mm; SP-5 Diameter of ports X, Y: Ø = 7 mm; Mass [kg] T TE, TES DPZO-*-5*,5,9 DPZO-*-7*,,8 DPZO-TE- SP-Z-7P or SP-ZM-7P DPZO-TES-*- SP-Z-7P or SP-ZM-7P SP-Z-5P/BP (for -BP) SP-Z-5P (for -PS and -BC) SP-5 SP-5 x SP-5 SP-5 -TE EXECUTION = pin connector SP-Z-P for option /Z -TES EXECUTION = pin connector SP-Z-P for options /SF, /SL, /SP, /Z x = M8 connector SP-Z-P-M8/5 moulded on cable 5 mt lenght for pressure or force transducer (options /SL, /SP) M8 connector SP-Z-P-M8/- moulded with cables, mt lenght for pressure transducers (options /SF) NOTE: For option /B the proportional solenoid, the position transducer and the electronics (in case of execution -TE and -TES) are at side of port A of the main stage F7

8 5 INSTALLATION DIMENSIONS FOR DPZO- [mm] DPZO-T(*)- (dotted line = double solenoid version) DPZO-T- SP-666 SP-5 DPZO-TE- SP-Z-7P or SP-ZM-7P SP-5 SP-5 ISO 0: 005 Mounting surface: (see table P005) Fastening bolts: 6 socket head screws Mx50 class 9 Tightening torque = 5 Nm Seals: OR ; OR 056 Diameter of ports A, B, P, T: Ø = mm; Diameter of ports X, Y: Ø = 7 mm; -TE EXECUTION = pin connector SP-Z-P for option /Z DPZO-TES-*- SP-Z-7P or SP-ZM-7P SP-Z-5P/BP (for -BP) SP-Z-5P (for -PS and -BC) x SP-5 SP-5 Mass [kg] T DPZO-*-5* 7, DPZO-*-7* 8 -TES EXECUTION = pin connector SP-Z-P for options /SF, /SL, /SP, /Z x = M8 connector SP-Z-P-M8/5 moulded on cable 5 mt lenght for pressure or force transducer (options /SL, /SP) M8 connector SP-Z-P-M8/- moulded with cables, mt lenght for pressure transducers (options /SF) TE, TES NOTE: For option /B the proportional solenoid, the position transducer and the electronics (in case of execution -TE and -TES) are at side of port A of the main stage 7,5 8, 6 MODEL CODES OF POWER SUPPLY AND COMMUNICATION CONNECTORS (to be ordered separatel) VALVE VERSION CONNECTOR CODE SP-666 SP-5 SP-Z-7P SP-ZM-7P SP-Z-P SP-Z-5P SP-Z-5P/BP PROTECTION DEGREE Power suppl Transducer IP65 connectors supplied with the valve -T -TE, -TES -TE/Z -TES /Z, /SF, /SL, /SP TES -PS, -BC TES -BP IP65 IP67 IP67 IP65 IP67 IP67 DATA SEET K500 G00, G0, K500 G0, K500 () M8 connector SP-Z-P-M8/5 moulded on cable 5 mt lenght for pressure or force transducer (options /SL, /SP) M8 connector SP-Z-P-M8/- moulded with cables, mt lenght for pressure transducers (options /SF) TES /SF, /SL, /SP SP-Z-P-M8/* () IP67 G, K500 0/09

Proportional directional valves type DPZO-T* two stage, with position transducer, ISO 4401 sizes 10, 16 and 25

Proportional directional valves type DPZO-T* two stage, with position transducer, ISO 4401 sizes 10, 16 and 25 wwwatoscom Table F7-/E Proportional directional valves tpe DPZO-T* two stage, with position transducer, ISO 0 sizes 0, 6 and 5 DPZO-T* are two stage proportional valves with position transducer on the

More information

Proportional throttle cartridges type LIQZO-T*, 2-way with position transducer, ISO 7368 sizes from 16 to 50

Proportional throttle cartridges type LIQZO-T*, 2-way with position transducer, ISO 7368 sizes from 16 to 50 www.atos.com Table F0-7/E Proportional throttle cartridges tpe LIQZO-T*, -wa with position transducer, ISO 768 sizes from 6 to 50 Poppet Sleeve Main stage position transducer Pilot valve Integral electronics

More information

Servoproportional valves type DLHZO and DLKZOR

Servoproportional valves type DLHZO and DLKZOR www.atos.com Table F180-16/E Servoproportional valves type DLZO and DLKZOR sleeve execution, direct operated, with position transducer, ISO 01 size 06 and 10 Valve body Spool Sleeve Proportional solenoid

More information

Proportional throttle cartridges type LIQZO-L*, 2-way high dynamics, with two position transducers, ISO 7368 sizes from 16 to 100

Proportional throttle cartridges type LIQZO-L*, 2-way high dynamics, with two position transducers, ISO 7368 sizes from 16 to 100 www.atos.com Table F00/E Proportional throttle cartridges tpe LIQZOL*, wa high dnamics, with two position transducers, ISO 768 sizes from 6 to 00 Poppet Sleeve Main stage position transducer Pilot valve

More information

Proportional relief valves type RZMO-A* with Pmax 500 bar direct operated, without integral pressure transducer, ISO 4401 size 06

Proportional relief valves type RZMO-A* with Pmax 500 bar direct operated, without integral pressure transducer, ISO 4401 size 06 able TF035-1/E Proportional relief valves tpe 110106 RZMO-A* with Pmax 500 bar direct operated, without integral pressure transducer, ISO 4401 size 06 9 10 Valve bod Proportional solenoid Spring Poppet

More information

Proportional directional valves type DHZO-TES and DKZOR-TES direct operated, with position transducer, ISO 4401 size 06 and 10

Proportional directional valves type DHZO-TES and DKZOR-TES direct operated, with position transducer, ISO 4401 size 06 and 10 www.atos.com Table F65-/E Proportional directional valves type DZO-TES and DKZOR-TES direct operated, with position transducer, ISO 440 size 06 and 0 TE and TES executions included in this table are available

More information

Proportional throttle cartridges type LIQZO-L*, 2-way high dynamics, with two position transducers, ISO 7368 sizes from 16 to 100

Proportional throttle cartridges type LIQZO-L*, 2-way high dynamics, with two position transducers, ISO 7368 sizes from 16 to 100 www.atos.com Table F00/E Proportional throttle cartridges tpe LIQZOL*, wa high dnamics, with two position transducers, ISO 768 sizes from 6 to Poppet Sleeve Main stage position transducer Pilot valve Integral

More information

Servoproportional valves type DLHZO-TE and DLKZOR-TE sleeve execution, direct operated, with position transducer, ISO 4401 size 06 and 10

Servoproportional valves type DLHZO-TE and DLKZOR-TE sleeve execution, direct operated, with position transducer, ISO 4401 size 06 and 10 www.atos.com Table F180-17/E Servoproportional valves type DLHZO-TE and DLKZOR-TE sleeve execution, direct operated, with position transducer, ISO 01 size 06 and 10 TE and TES executions included in this

More information

Proportional throttle cartridges type LEQZO-A*, 2-way without position transducer, nominal sizes 16, 25 and 32

Proportional throttle cartridges type LEQZO-A*, 2-way without position transducer, nominal sizes 16, 25 and 32 www.atos.com Table F310-5/E Proportional throttle cartridges type LEQZO-A*, 2-way without position transducer, nominal sizes 16, 25 and 32 Spool Cartridge Pilot valve Integral electronics Communication

More information

Proportional relief valves type RZMO-A*

Proportional relief valves type RZMO-A* www.atos.com Table F007-9/E Proportional relief valves type RZMO-A* direct operated, without integral pressure transducer, ISO 440 size 06 Valve body Proportional solenoid Spring Poppet Integral electronics

More information

Proportional throttle cartridges type LIQZO-L*, 3-way high dynamics, with two position transducers, sizes from 25 to 80

Proportional throttle cartridges type LIQZO-L*, 3-way high dynamics, with two position transducers, sizes from 25 to 80 www.atos.com Table F07/E Proptional throttle cartridges tpe LIQZOL*, wa high dnamics, with two position transducers, sizes from 5 to 80 Poppet Sleeve Main stage position transducer Pilot valve Integral

More information

Proportional relief valves type RZMO-A* direct operated, without integral pressure transducer, ISO 4401 size 06

Proportional relief valves type RZMO-A* direct operated, without integral pressure transducer, ISO 4401 size 06 www.atos.com Table F007-20/E Proportional relief valves type RZMO-A* direct operated, without integral pressure transducer, ISO 440 size 06 Valve body Proportional solenoid Spring Poppet Integral electronics

More information

Proportional relief valves type AGMZO-A* two stage, without integral pressure transducer, ISO 6264 size 10, 20 and 32

Proportional relief valves type AGMZO-A* two stage, without integral pressure transducer, ISO 6264 size 10, 20 and 32 www.atos.com Table F035-19/E Proportional relief valves type AGMZO-A* two stage, without integral pressure transducer, ISO 6264 size 10, 20 and 32 Main poppet Pilot relief valve type RZMO Mechanical pilot

More information

Proportional relief valves type AGMZO-AES two stage, without integral pressure transducer, ISO 6264 size 10, 20 and 32

Proportional relief valves type AGMZO-AES two stage, without integral pressure transducer, ISO 6264 size 10, 20 and 32 www.atos.com Table F035-20/E Proportional relief valves type AGMZO-AES two stage, without integral pressure transducer, ISO 6264 size 10, 20 and 32 1 MODEL CODE AGMZO Proportional pressure relief valve

More information

Proportional reducing valves type AGRCZO-AES two stages, normally closed, without integral pressure transducer, ISO 5781 size 10 and 20

Proportional reducing valves type AGRCZO-AES two stages, normally closed, without integral pressure transducer, ISO 5781 size 10 and 20 www.atos.com Table F050-8/E Proportional reducing valves type AGRCZO-AES two stages, normally closed, without integral pressure transducer, ISO 5781 size 10 and 20 Main poppet Pilot relief valve type RZMO

More information

Proportional 2-way throttle cartridges high dynamics, with two position transducers, ISO 7368 sizes from 16 to 100

Proportional 2-way throttle cartridges high dynamics, with two position transducers, ISO 7368 sizes from 16 to 100 www.atos.com Table F0/E Proportional way throttle cartridges high dynamics, with two position transducers, ISO 768 sizes from 6 to LE and LES executions included in this table are available only for running

More information

Seals material: omit for NBR (mineral oil & water glycol) PE = FPM. Series number

Seals material: omit for NBR (mineral oil & water glycol) PE = FPM. Series number www.atos.com Table F40-6/E Proportional flow valves type QVHZO-AES, QVKZOR-AES pressure compensated, direct operated, without position transducer, ISO 440 size 06 and 0 AES execution included in this table

More information

Proportional electrohydraulic controls for PVPC pumps pressure-flow combined P/Q controls, analog or digital

Proportional electrohydraulic controls for PVPC pumps pressure-flow combined P/Q controls, analog or digital www.atos.com Table A70/E Proportional electrohydraulic controls for PVPC pumps pressureflow combined P/Q controls, analog or digital The variable displacement axial piston pumps type PVPC, can be supplied

More information

Proportional pressure valves with remote pressure transducer digital, closed loop high performances, rugged design

Proportional pressure valves with remote pressure transducer digital, closed loop high performances, rugged design www.atos.com Table TFS100-1/E Proportional pressure valves with remote pressure transducer digital, closed loop high performances, rugged design T P RZMO-RES-N-NP-010 Proportional pressure relief and reducing

More information

High Performance proportional 2-way cartridges with two position transducers, ISO 7368 sizes from 16 to 100

High Performance proportional 2-way cartridges with two position transducers, ISO 7368 sizes from 16 to 100 www.atos.com Table F330-2/E High Performance proportional 2-way cartridges with two position transducers, ISO 7368 sizes from 6 to 00 Poppet Sleeve Main stage position transducer Pilot valve Integral electronics

More information

Digital electronic TES/LES drivers integral-to-valve format, for proportional valves with one or two spool position transducers

Digital electronic TES/LES drivers integral-to-valve format, for proportional valves with one or two spool position transducers www.atos.com Table GS210-3/E Digital electronic TES/LES drivers integral-to-valve format, for proportional valves with one or two spool position transducers Scale Bias Linearization Ramps Real Time Fieldbus

More information

Digital electronic REB/RES drivers integral-to-valve format, for proportional valves with integral pressure transducer

Digital electronic REB/RES drivers integral-to-valve format, for proportional valves with integral pressure transducer Table GS205-1/E Digital electronic RE/RES drivers integral-to-valve format, for proportional valves with integral pressure transducer RE, RES RZMO- RE - P - NP Not Present Digital drivers supply and control,

More information

TWO CHANNELS REDUNDANT SAFETY ARCHITECTURE SINGLE CHANNEL NON-REDUNDANT SAFETY ARCHITECTURE

TWO CHANNELS REDUNDANT SAFETY ARCHITECTURE SINGLE CHANNEL NON-REDUNDANT SAFETY ARCHITECTURE Table FY100-0/E Safety proportional valves with double power supply - option /U digital, direct or piloted operated, with one or two position transducers IEC 61508 Safety Integrity Level and ISO 13849

More information

Proportional 2-way cartridges high performance digital, with two position transducers, ISO 7368 sizes from 16 to 100, rugged design

Proportional 2-way cartridges high performance digital, with two position transducers, ISO 7368 sizes from 16 to 100, rugged design Table FS330-4/E Proportional 2-way cartridges high performance digital, with two position transducers, ISO 7368 sizes from 6 to, rugged design Poppet Sleeve Main stage position transducer Pilot valve Integral

More information

Hydraulic Power Limitation. Real Time Fieldbus Reference. Enhanced Diagnostic. E-SW programming software. Set code (see note) Series number

Hydraulic Power Limitation. Real Time Fieldbus Reference. Enhanced Diagnostic. E-SW programming software. Set code (see note) Series number www.atos.com Table G215obs/E Digital electronic drivers type E-RI-PES integral-to-valve format, for variable displacement axial piston pumps with alternate P/Q control obsolete components - availability

More information

Servoproportional 3-way cartridges digital, with two position transducers, sizes from 25 to 80, rugged design

Servoproportional 3-way cartridges digital, with two position transducers, sizes from 25 to 80, rugged design Table FS340-3/E Servoproportional 3-way cartridges digital, with two position transducers, sizes from 2 to 80, rugged design Main Spool Sleeve Main stage position transducer Pilot valve Integral electronics

More information

Proportional 2-way cartridges high performance rugged digital, with two position transducers, ISO 7368 sizes from 16 to 100

Proportional 2-way cartridges high performance rugged digital, with two position transducers, ISO 7368 sizes from 16 to 100 www.atos.com Table FS/E Proportional 2way cartridges high performance rugged digital, with two position transducers, ISO 7 sizes from to Poppet Sleeve Main stage position transducer Pilot valve Integral

More information

Programming tools for digital electronics Atos PC software, USB adapters, cables and terminators

Programming tools for digital electronics Atos PC software, USB adapters, cables and terminators www.atos.com Table GS00-/E Programming tools for digital electronics Atos PC software, adapters, cables and terminators POWER SUPPLY 4VDC direct PC connection POWER SUPPLY 4VDC adapter PC connection Programming

More information

Programming tools for digital electronics Atos PC software, USB adapters, cables and terminators

Programming tools for digital electronics Atos PC software, USB adapters, cables and terminators www.atos.com Table GS00-0/E Programming tools for digital electronics Atos PC software, adapters, cables and terminators POWER SUPPLY 4VDC Programming software Personal Computer Isolator Cable Proportional

More information

Two stage proportional directional valves high performance digital with two position transducers and positive spool overlap, rugged design

Two stage proportional directional valves high performance digital with two position transducers and positive spool overlap, rugged design Table FS1753/E Two stage proportional directional valves high performance digital with two position transducers and positive spool overlap, rugged design Valve body Main stage Spool Pilot valve DPZOLESSNBP271

More information

ISO cartridge valves type LID* Check function, ISO 7368 size from 16 to 100, high flow, Pmax 420 bar

ISO cartridge valves type LID* Check function, ISO 7368 size from 16 to 100, high flow, Pmax 420 bar Table H0409/E ISO cartridge valves type LID* Check function, ISO 78 size from to 00, high flow, Pmax 40 bar Functional cover Poppet Sleeve LIDO Spring Pilot operated check valve LIDR Directional control

More information

Programming tools for digital electronics Atos PC software, USB adapters, cables and terminators

Programming tools for digital electronics Atos PC software, USB adapters, cables and terminators Atos spa - via alla Piana, 7 08 Sesto Calende - Varese - Italy COM BTH Table GS00-/E Programming tools for digital electronics Atos PC software, adapters, cables and terminators Digital electrohydraulic

More information

Analog or Digital 08E001 RI-* drivers

Analog or Digital 08E001 RI-* drivers www.atos.com Table T040obs/ Analog or igital 08001 RI-* drivers box format, for proportional valves with or without transducer(s) Scale Real-time ieldbus Reference ias nhanced iagnostic rey area: digital

More information

Digital electropneumatic Positioner for the integrated mounting on process control valves

Digital electropneumatic Positioner for the integrated mounting on process control valves Digital electropneumatic Positioner for the integrated mounting on process control valves Type 8692 can be combined with Compact stainless steel design Graphic display with backlight Easy start-up Comprehensive

More information

Digital electropneumatic Positioner for the integrated mounting on process control valves

Digital electropneumatic Positioner for the integrated mounting on process control valves Digital electropneumatic Positioner for the integd mounting on process control valves Type 8692 can be combined with Compact stainless steel design Graphic display with backlight Easy start-up by automatic

More information

LFC Liquid Flow Controller

LFC Liquid Flow Controller LFC Liquid Flow Controller Type 879 can be combined with High dynamic control through fast flow measurement Applicable for liquid dosing up to 600 ml/min (6 l/h) No moving parts in medium Fieldbus optional

More information

Proportional controls for PVPC pumps analog pressure or flow, digital P/Q controls

Proportional controls for PVPC pumps analog pressure or flow, digital P/Q controls Table S702/E Proportional controls for PVPC pumps analog pressure or flow, digital P/Q controls pump body proportional valve integral electronics with P/Q controller USB connector PVPCPESSPBC4046 swash

More information

Valve terminal RE-10 with Multi-pin, AS-Interface or bus connection 4 12 valve stations, 300 Nl/min (0.305 Cv)

Valve terminal RE-10 with Multi-pin, AS-Interface or bus connection 4 12 valve stations, 300 Nl/min (0.305 Cv) Type of connection = AS = B1 = B6 Order code RE-10/08-M-1-060 Series Number of stations Multi-pin: 4, 6, 8, 10, 12 Bus versions: 4, 8, 12 Electrical options M-1 = Multi-pin D-Sub plug AS3 = AS-Interface

More information

Control Head for the integrated mounting on process valves

Control Head for the integrated mounting on process valves Control Head for the integrated mounting on process valves Type can be combined with Compact stainless steel design Integrated analogue valve position registration (Teach function) Coloured illuminated

More information

Power Amplifiers for PVH-EDC Pumps

Power Amplifiers for PVH-EDC Pumps Vickers Accessories Power Amplifiers for PVH-EDC Pumps EEA-EDC-436-A*-32 Design A1 - For use with PVH57 & 74 A2 - For use with PVH98 A3 - For use with PVH131 Panel Display General Description These amplifiers

More information

Extruder Controls ExtruVision S

Extruder Controls ExtruVision S Extruder Controls ExtruVision S ExtruVision S - The compact system solution for controlling, visualization, and operating extrusion systems Combination of control panel BA Touch with 5.7'' monitor and

More information

Control Head for the integrated mounting on process valves

Control Head for the integrated mounting on process valves Control Head for the integrated mounting on process valves Type 8691 can be combined with Compact stainless steel design Integrated analogue valve position registration (Teach function) Coloured illuminated

More information

Digital electropneumatic positioner

Digital electropneumatic positioner Digital electropneumatic positioner Type 879 can be combined with Compact metal housing Graphic display with backlight Easy start-up Comprehensive range of additional software functions Profibus DPV1 (optional)

More information

Electronic pressure switch with display Model PSD-4

Electronic pressure switch with display Model PSD-4 Electronic pressure measurement Electronic pressure switch with display Model PSD-4 WIKA data sheet PE 81.86 Applications Machine tools Hydraulics and pneumatics Pumps and compressors Special-purpose machine

More information

Inclination sensors 2-dimensional, measuring range up to ±90

Inclination sensors 2-dimensional, measuring range up to ±90 Features Size 52 mm MEMS capacitive measuring principle EN13849 compliant firmware E1 compliant design Interface CANopen, SAE J1939, Analog Connection M12 and cable Protection up to IP 69K Optional GIM500R

More information

Control Head for the integrated mounting on process valves

Control Head for the integrated mounting on process valves Control Head for the integrated mounting on process valves Type 8695 can be combined with Compact stainless steel design Integrated analog valve position registration (Teach function) Coloured illuminated

More information

TM7NCOM16A CANopen interface block - IP67-16 I/O - M12

TM7NCOM16A CANopen interface block - IP67-16 I/O - M12 Characteristics CANopen interface block - IP67-16 I/O - M12 Main Range of product Product or component type Range compatibility Enclosure material Bus type [Ue] rated operational voltage Input/Output number

More information

CPX-Terminal. Brief description. CPX analogue I/O modules CPX-4AE CPX-2AA. English e [ ]

CPX-Terminal. Brief description. CPX analogue I/O modules CPX-4AE CPX-2AA. English e [ ] CPX-Terminal Brief description CPX analogue I/O modules CPX-2AE CPX-4AE CPX-2AA English 8080173 2017-11e [8080175] Translation of the original instructions Documentation on the product For all available

More information

Pneumatic Control Unit for the integrated mounting on process valves

Pneumatic Control Unit for the integrated mounting on process valves Pneumatic Control Unit for the integrated mounting on process valves Type 890 can be combined with Compact design Pilot valve with high air flow rate Internal control air channel Optical position indicator

More information

Digital electropneumatic positioner

Digital electropneumatic positioner Digital electropneumatic positioner Type 879 can be combined with Compact metal housing Graphic display with backlight Easy start-up Comprehensive range of additional software functions Profibus DPV1 (optional)

More information

Installation Manual Series PQ-L. Electronic Module. Bulletin /UK

Installation Manual Series PQ-L. Electronic Module.  Bulletin /UK Bulletin 5715-571 /UK Installation Manual Electronic Module Gutenbergstr. 38 41564 Kaarst, Germany Tel.: (+) 2131-513-0 Fax: (+) 2131-513-230 www.parker.com Copyright Ó 2000, Note This document and other

More information

Temperature Switches

Temperature Switches ETS 00 Series Temperature Switch for Inline and Tank Mounting Applications Description The ETS 00 is a compact electronic temperature switch with 4-digit digital display. Pressure resistant to 8700 psi,

More information

TECHNICAL DATASHEET Absolute Encoder AC 58 - Profibus

TECHNICAL DATASHEET Absolute Encoder AC 58 - Profibus Diagnostic LED Cable or M12 connector Output of speed, acceleration Programmable: Resolution, Preset, Direction, Operation time Option: Display "tico" Address via interface parameterizable (optional) hubshaft

More information

MINI MCR-SL-PT100-UI-200

MINI MCR-SL-PT100-UI-200 Configurable temperature transducer for PT00 INTERFACE Data sheet 078_en_0 PHOENIX CONTACT 00-0-5 Description The MINI MCR-SL-PT00-UI-00... is a configurable -way isolated temperature transducer. It is

More information

Electronic Control Unit RC

Electronic Control Unit RC Industrial Hydraulics Electric Drives and Controls Linear Motion and Assembly Technologies Pneumatics Service Automation Mobile Hydraulics Electronic Control Unit RC RE 900/.0 /6 Replaces: 09.0 Series

More information

Expansion Module HZS 541-1S

Expansion Module HZS 541-1S Expansion Module HZS 541-1S 12.10.2015 Page 1 System Description The external HZS 541-1S expansion module provides users of biomass heating systems with additional 230 V AC relay outputs, analog inputs

More information

MINI MCR-SL-UI-2I. Configurable signal duplicator. Data sheet. 1 Description

MINI MCR-SL-UI-2I. Configurable signal duplicator. Data sheet. 1 Description Configurable signal duplicator Data sheet 102382_en_03 PHOENIX CONTACT 2012-05-02 1 Description The MINI MCR-SL-UI-2I(-SP)(-NC) configurable signal duplicator is used to electrically isolate, condition,

More information

D115 The Fast Optimal Servo Amplifier For Brush, Brushless, Voice Coil Servo Motors

D115 The Fast Optimal Servo Amplifier For Brush, Brushless, Voice Coil Servo Motors D115 The Fast Optimal Servo Amplifier For Brush, Brushless, Voice Coil Servo Motors Ron Boe 5/15/2014 This user guide details the servo drives capabilities and physical interfaces. Users will be able to

More information

MINI MCR-SL-PT100-UI. Active resistance thermometer measuring transducer. Data sheet. 1 Description

MINI MCR-SL-PT100-UI. Active resistance thermometer measuring transducer. Data sheet. 1 Description Active resistance thermometer measuring transducer Data sheet 099_en_06 PHOENIX CONTACT 0-0- Description The 6. mm wide MINI MCR-SL-PT00-UI-... is a configurable, -way isolated temperature measuring transducer.

More information

Safety System CES-FD. Non-contact safety system CES-FD- Direct connection to decentralized peripheral systems (e.g. ET200pro) PLC

Safety System CES-FD. Non-contact safety system CES-FD- Direct connection to decentralized peripheral systems (e.g. ET200pro) PLC Non-contact safety system CES-FD- Evaluation of signals in the field Connection of CES read heads Connection to the ET200s and ET200pro Familiar EUCHNER AP interface Functional description Field evaluation

More information

Standardized valve series MI-01 Connection pattern according to ISO 5599/1, size 1, 5/2- and 5/3-way NG and 1700 Nl/min (1.636 and 1.

Standardized valve series MI-01 Connection pattern according to ISO 5599/1, size 1, 5/2- and 5/3-way NG and 1700 Nl/min (1.636 and 1. Standardized valve series MI-01 Connection pattern according to ISO 5599/1, size 1, 5/2- and 5/3-way NG 9 1610 and 1700 Nl/min (1.636 and 1.728 Cv) Order code Series and function 1) Plug socket see page

More information

EC centrifugal module - RadiPac

EC centrifugal module - RadiPac KG9-AR- ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-7467 Mulfingen Phone +49 8 8- Fax +49 8 8- info@de.ebmpapst.com www.ebmpapst.com Limited partnership Headquarters Mulfingen County court Stuttgart

More information

Mass Flow Meter (MFM) for Gases

Mass Flow Meter (MFM) for Gases 871 Mass Flow Meter (MFM for Gases Type 871 can be combined with Direct flow measurement for nominal flow rates from 1 ml N /min to 8 l N /min (N 2 in MEMS technology High accuracy Short response time

More information

MiniAmp. Electronics & Software. Miniature Charge Amplifier. Type 5030A...

MiniAmp. Electronics & Software. Miniature Charge Amplifier. Type 5030A... Electronics & Software MiniAmp Type 5030A... Miniature Charge Amplifier The MiniAmp Type 5030A is a single channel, industrial charge amplifier, which converts the charge signal from piezoelectric sensors

More information

EC centrifugal module - RadiPac

EC centrifugal module - RadiPac KG9-AS8- ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-7 Mulfingen Phone +9 798 8- Fax +9 798 8- info@de.ebmpapst.com www.ebmpapst.com Limited partnership Headquarters Mulfingen County court Stuttgart

More information

SUBCON-PLUS-PROFIB...

SUBCON-PLUS-PROFIB... Fast connector for PROFIBUS systems Data sheet 101610_en_10 PHOENIX CONTACT 2017-03-27 1 Description The SUBCON-PLUS-PROFIB... D-SUB series is specifically designed for use in PROFIBUS systems up to 12

More information

icountpd Online Particle Detector

icountpd Online Particle Detector Online Particle Detector The icountpd from Parker represents the most up-to-date technology in solid particle detection. The design dynamics, attention to detail, and small size of the permanently mounted,

More information

MINI MCR-SL-CVS NC

MINI MCR-SL-CVS NC Constant voltage source Data sheet 105264_en_01 PHOENIX CONTACT 2013-04-03 1 Description Configurable constant voltage source for generating highprecision constant voltages. The voltage supply is also

More information

EC axial fan - HyBlade

EC axial fan - HyBlade WG-HU- ebm-papst Mulfingen GmbH & Co. KG Bachmühle D- Mulfingen Phone +9 9 - Fax +9 9 - info@de.ebmpapst.com www.ebmpapst.com Limited partnership Headquarters Mulfingen County court Stuttgart HRA 59 General

More information

VersaMax IP I/O Module

VersaMax IP I/O Module Module accepts four digital input signals and provides four digital outputs. It connects to a local bus that is interfaced to a Profibus-DP / PROFINET network by a Profibus Interface Unit (IC677PBI001)

More information

97100 NAMUR series, 3/2 & 5/2 Indirect solenoid actuated spool valve

97100 NAMUR series, 3/2 & 5/2 Indirect solenoid actuated spool valve 9700 NAMUR series, / & / > > Port size: /4 (ISO G or NPT), NAMUR Interface > > Crossover-free switching > > Main application: Single and double acting actuators > > / way valve usable as / way valve >

More information

RK-2 CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER WITH FLANGED HEAD

RK-2 CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER WITH FLANGED HEAD RK-2 CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER WITH FLANGED HEAD (ANALOG OR START/STOP OUTPUT) Main characteristics Absolute transducer Strokes from 50 to 4000mm (RK-2- -N/E/S) Digital output

More information

Electric Actuators Type 5824 (without fail-safe action) Type 5825 (with fail-safe action)

Electric Actuators Type 5824 (without fail-safe action) Type 5825 (with fail-safe action) Electric Actuators Type 5824 (without fail-safe action) Type 5825 (with fail-safe action) Application Electric actuators designed for valves used in heating, ventilation and air-conditioning systems as

More information

Multipole and Fieldbus

Multipole and Fieldbus > Series 3 Plug-In valve islands Valve Islands > 016 Series 3 Plug-In valve islands, Multipole and Fieldbus New versions Plug-In system for Series 3 solenoid valves, G1/8 port. Valve functions: x3/, 5/

More information

C-Flow Coriolis Mass Flow Meter

C-Flow Coriolis Mass Flow Meter Coriolis Mass Flow Meter Application and Features For fluids (e.g. PU components, paints) and gases of high density Suitable for aggressive and contaminated media Measurement of mass flow, density, temperature

More information

ATV32HU11M2437 variable speed drive ATV32-1.1kW 200V - 1P - Bluetooth built-in - w heat sink

ATV32HU11M2437 variable speed drive ATV32-1.1kW 200V - 1P - Bluetooth built-in - w heat sink Characteristics variable speed drive ATV32-1.1kW 200V - 1P - Bluetooth built-in - w heat sink Main Range of product Altivar 32 Product or component type Product destination Product specific application

More information

Lighting Controls and Connectivity scenecom. scenecom L, XL, XL EM and XL EM Bac scenecom Controller

Lighting Controls and Connectivity scenecom. scenecom L, XL, XL EM and XL EM Bac scenecom Controller L, XL, XL EM and XL EM Bac Controller Product description Independent lighting control for up to 192 DALI control gears on 3 DALI lines Simple setup via WEB interface Cross DALI line control Freel programmable

More information

TECHNICAL DATASHEET #TDAX023300

TECHNICAL DATASHEET #TDAX023300 Preliminary TECHNICAL DATASHEET #TDAX023300 2 Universal Inputs, Dual Universal Valve Controller 2 Universal Inputs 2-3A Outputs CAN (SAE J1939) Configurable with Electronic Assistant P/N: AX023300 Features

More information

Fieldbus System. New. New. Series EX260 IP67. Drives up to 32 solenoids. Daisy-chain wiring communication. Compact 28mm

Fieldbus System. New. New. Series EX260 IP67. Drives up to 32 solenoids. Daisy-chain wiring communication. Compact 28mm Fieldbus System (Output device for driving port solenoid valves) Compact 8mm (Actual size) Space-saving Installation Daisy-chain wiring communication New IP67 For units with D-sub connector, and when connected

More information

Control head for hygienic process valves

Control head for hygienic process valves for hygienic process valves Type can be combined with... Universal attachment for hygienic process valves Contactless position measurement system with 3 switching points (Teach-In function) Coloured status

More information

RE 50220/ Type ABZMS-40. Component series 1X Maximum operating pressure 1 bar 1/10

RE 50220/ Type ABZMS-40. Component series 1X Maximum operating pressure 1 bar 1/10 Float switch with two switching contacts, two programmable switching outputs for temperature, alternatively one programmable switching output and one analog output with display and control unit E 50220/07.0

More information

Flowtronic D 607 Series

Flowtronic D 607 Series Flowtronic D 607 Series Proportional Technology www.asco.com FLOW CONTROL: 607 SERIES FLOWTRONIC D Flowtronic D Flowtronic D is a digitally operated flow controller up to 70 SCFM (2000 Nl/min). The Flowtronic

More information

Rhino PSM Power Supplies. Operating Instructions

Rhino PSM Power Supplies. Operating Instructions Rhino PSM Power Supplies Operating Instructions RHINO Power Supplies PSM Series Description The PSM power supplies are built-in units. The mounting position for PSM power supplies must fulfill the requirements

More information

EC centrifugal module - RadiPac

EC centrifugal module - RadiPac K3G-AP25-1 ebm-papst Mulfingen GmbH & Co. KG Bachmühle 2 D-74673 Mulfingen Phone +49 7938 81- Fax +49 7938 81-11 info1@de.ebmpapst.com www.ebmpapst.com Limited partnership Headquarters Mulfingen County

More information

B&R X67_IO_System_V3.14_E. X67 - System

B&R X67_IO_System_V3.14_E. X67 - System B&R X67_IO_System_V3.14_E X67 - System X67 I/O System - Benefits to the User Why I/Os in the IP67? Potential of the remote machine concept Cost reduction with remote I/O concept Reduced wiring Minimization

More information

Mating connectors and cable sets for valves and sensors in hydraulics

Mating connectors and cable sets for valves and sensors in hydraulics s and cable sets for valves and sensors in hydraulics RE 08006 Edition: 06-04 Replaces: 0. Features s and cable sets for electrical connection of: - Valve solenoids - Valves with integrated electronics

More information

MINI MCR-SL-RPS-I-I. Repeater power supply, active. Data sheet. 1 Description

MINI MCR-SL-RPS-I-I. Repeater power supply, active. Data sheet. 1 Description Repeater power supply, active Data sheet 09_en_0 PHOENIX CONTACT 0--0 Description The. mm wide... repeater power supply supplies transmitters in the field and electrically isolates the input signal from

More information

Inductive angle sensor with analog output Ri360P1-DSU35TC-ELi-Exi

Inductive angle sensor with analog output Ri360P1-DSU35TC-ELi-Exi ATEX category II 2 G, Ex Zone 1 ATEX category II 2 D, Ex Zone 21 Rectangular, housing DSU35 Plastic, PP-GF30-VO Detection of angular range 0 to 360 P1-Ri-QR14 positioning element included in delivery Measuring

More information

TB3P/TB4P I/O PROFIBUS DP FIELDBUS MODULE FOR PNEUMATIC MANIFOLD VALVES. Pg. 1 di 14

TB3P/TB4P I/O PROFIBUS DP FIELDBUS MODULE FOR PNEUMATIC MANIFOLD VALVES. Pg. 1 di 14 TB3P/TB4P I/O PROFIBUS DP FIELDBUS MODULE FOR PNEUMATIC MANIFOLD VALVES Pg. 1 di 14 INDEX Legend of Symbols... 3 Conformity Declaration... 3 System Descripiton... 4 Module Specifications... 4 Installation

More information

Manual English. for the Devices of the MVK-MPNIO Safety Series MVK-MPNIO F DI16/8 Art. No and MVK-MPNIO F DI8/4 F DO4 Art. No.

Manual English. for the Devices of the MVK-MPNIO Safety Series MVK-MPNIO F DI16/8 Art. No and MVK-MPNIO F DI8/4 F DO4 Art. No. Introduction For Your Safety Description Installation Startup Configuration Run Mode Maintenance and Cleaning Manual English for the Devices of the Series MVK-MPNIO F DI16/8 Art. No. 55560 and MVK-MPNIO

More information

Flow measurement FlexFlow PF20S Flow sensor for industrial applications

Flow measurement FlexFlow PF20S Flow sensor for industrial applications Product highlights Parallel measurement of flow and temperature Flow measurement independent of the mounting position Large measuring range up to 400 cm/s Measurement at high media temperatures up to 125

More information

PKP Prozessmesstechnik GmbH. Borsigstrasse 24. D Wiesbaden-Nordenstadt. Tel: / Fax: / Operating manual PSA06

PKP Prozessmesstechnik GmbH. Borsigstrasse 24. D Wiesbaden-Nordenstadt. Tel: / Fax: / Operating manual PSA06 PKP Prozessmesstechnik GmbH Borsigstrasse 24 D-65205 Wiesbaden-Nordenstadt Tel: 06122 / 7055-0 Fax: 06122 / 7055 50 Operating manual PSA06 Electronical pressure switch Content Page 19-34 1. Foreword 19

More information

26360, Inline. Technical data. Ordering information See page 2. For connector plugs see page 2 and data sheets N/en /2 5/2.

26360, Inline. Technical data. Ordering information See page 2. For connector plugs see page 2 and data sheets N/en /2 5/2. 66, 87 Inline / and 5/ directional control valves NG 6 and Operation: elektromagnetic Indirectly controlled soft seal spool valves Port size: G /4 and G / For single and double operated actuators Manual

More information

Digital electropneumatic Positioner for the integrated mounting on process control valves

Digital electropneumatic Positioner for the integrated mounting on process control valves Digital electropneumatic Positioner for the integrated mounting on process s Type 8694 can be combined with Digital smart positioner Automatic teach function Contact-free position sensor Compact stainless

More information

IK4A (with ONDA technology)

IK4A (with ONDA technology) IK4A (with ONDA technology) CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER (ANALOG OUTPUT) Main characteristics ONDA technology Optimized mechanical structure Strokes from 50 to 4000 Wide range

More information

PHOENIX CONTACT - 01/2008

PHOENIX CONTACT - 01/2008 Ex Basic Terminal Blocks for Intrinsically Safe Signals With Knife Disconnection and Test Connections INTERFACE Data Sheet 102957_00_en PHOENIX CONTACT - 01/2008 1 Description PI-EX-TB and PI-EX-TB/T Ex

More information

Operation Manual. Fieldbus system EX510-GPR1. PROFIBUS DP Compatible GW unit

Operation Manual. Fieldbus system EX510-GPR1. PROFIBUS DP Compatible GW unit Fieldbus system PROFIBUS DP Compatible GW unit Operation Manual EX50-GPR URL http://www.smcworld.com Akihabara UDX 5F, --, Sotokanda, Chiyoda-ku, Tokyo 0-00, JAPAN Phone: +8 3-507-89 Fax: +8 3-598-536

More information

Digital electropneumatic positioner SideControl

Digital electropneumatic positioner SideControl Digital electropneumatic positioner Type 879 can be combined with Compact and robust design Easy to start using tune function Integrated diagnostic functions for valve monitoring (optional) Dynamic positioning

More information

Products no longer available

Products no longer available echnical data sheet NV4-MF(-) Modulating linear actuator for -way and 3-way globe valves Actuating force 1000 N Nominal voltage AC/DC 4 V Modulating control DC 0... 10 V Position osition feedback feedbac

More information

Inclination sensors 1-dimensional, measuring range

Inclination sensors 1-dimensional, measuring range Features Size 52 mm MEMS capacitive measuring principle EN13849 compliant firmware E1 compliant design Interface CANopen, SAE J1939, Analog Connection M12 and cable Protection up to IP 69K Optional GIM500R

More information