Table of Contents. Lucas Nülle GmbH Page 1/118

Size: px
Start display at page:

Download "Table of Contents. Lucas Nülle GmbH Page 1/118"

Transcription

1 Table of Contents Table of Contents Electrical Power Engineering, Smart Grid Trainers Power transmission EUL High-voltage transmission lines EUL 1 Investigations on Three-phase Transmission Lines EUL 2 Parallel and series connection of transmission lines EUL 3 Transmission Line with Earth-fault Compensation EUL 4 Transmission Systems with a Synchronous Generator EUL 5 Investigations on three phase cables EUL 6 Combined networks of cables and lines EUL 7 Controlling flow of power in meshed networks EUL 8 Load-dependent voltage regulation of a power transmission line Lucas Nülle GmbH Page 1/118

2 Electrical Power Engineering, Smart Grid Trainers Training systems on the generation, distribution and management of electrical energy: Power engineering training system, distribution training system Energy generation training system, renewable energy generation training system Transformer training system, high-voltage transmission lines training system, protective systems training system Energy management training system, smart grid training systems The Lucas-Nülle training systems have been designed in anticipation of the newest developments: Smart measuring instruments provided with various communication interfaces (e.g. LAN, RS485, USB) and control elements SCADA Power Engineering Lab software for the intelligent control and evaluation of "smart grids" using Soft PLC SCADA software designed for educational purposes Permits investigation of dynamically alternating loads and power generation inside the laboratory Intelligent energy management Modular integration of renewable energies into a smart grid using protective engineering Wind power plant with doubly-fed asynchronous generator (DFIG) and synchronisation to the grid Interactive multimedia training course Training systems on the generation, distribution and management of electrical energy: Power engineering trainer, distribution trainer Energy generation trainer, renewable energy generation trainer Transformer trainer, high-voltage transmission lines trainer, protective systems trainer Energy management trainer, smart grid trainers The Lucas-Nülle training systems have been designed in anticipation of the newest developments: Smart measuring instruments which avail of various communication interfaces (e.g. LAN, RS485, USB) and control elements SCADA Power Engineering Lab software for the intelligent control and evaluation of the "Smart Grid" with soft plc Didactically designed SCADA software Permits investigation of dynamically alternating loads and power generation inside the laboratory Intelligent energy management Modular integration of renewable energies into the smart grid using protective engineering Wind power plant with doubly-fed asynchronous generator (DFIG) with mains sychronisation Interactive multimedia training course Power transmission Lucas Nülle GmbH Page 2/118

3 Power transmission High-voltage networks are usually operated with voltages in the region of 110 kv to 380 kv, whereby urban areas and large-scale industrial facilities are supplied with 110 kv, and 380 kv is used for long-distance transmission lines. The line simulation system is designed for operation at model voltages between 110 V and 380 V. Various voltage levels and line lengths can be selected via corresponding overlay masks. Examinations with the training system can be performed off-load, in normal operating mode, in the presence of a short-circuit or earth fault, with or without earth-fault compensation. The system also permits assembly of complex networks by connecting the line simulation models in parallel or series. The voltage can be supplied via a fixed grid or synchronous generator. Lucas Nülle GmbH Page 3/118

4 EUL High-voltage transmission lines EUL High-voltage transmission lines For your safety, this investigation of 380-kV and 110-kV transmission lines and how they are connected together is carried out using low voltage, but without losing the actual properties of genuine high-voltage lines. These realistic simulations of a 380-kV transmission line and a 110-kV cable link are automatically switched between different line lengths once the appropriate overlay mask is put in place. By using simulations of various line lengths, it is possible to assemble complex transmission networks. Earth-fault compensation in electric power supply networks is designed to offset earth leakages occurring in outer conductors. Restricted to three-phase systems, earth-fault compensation makes use of a special Petersen coil named after its inventor and which is also known as an earth-fault quenching coil. This coil compensates the electric current at the earth-fault point, thereby preventing consequential malfunctions in the electrical system. The objective here is to measure characteristic power transmission parameters on simulated, three-phase, parallel-connected lines fed via a fixed network or a generator, and perform quantitative as well as qualitative assessments of operational relationships. Lucas Nülle GmbH Page 4/118

5 EUL 1 Investigations on Three-phase Transmission Lines EUL 1 Investigations on Three-phase Transmission Lines Training contents: Voltage increases on open-circuit lines Voltage drop as a function of line length Voltage drop as a function of cos-phi Capacitive and inductive power losses on a line as a function of U and I Phase shift on a line Lucas Nülle GmbH Page 5/118

6 Basic equipment set, consisting of: Basic equipment set, consisting of: Pos. Product name Bestell-Nr. Anz. 1 Transmission line Model 150km/300km (93.2miles/186.4miles) CO3301-3A 1 Three-phase line simulation of a high voltage overhead power line with different lengths for measuring various operational states (open-line, matched, short-circuit). Scale factor 1/1000 for current and voltage. Automatic modification of wire length as soon as the corresponding overlay is in place. Transmission line length: 150km or 300km Transmission line length: 93.2 miles or miles Resistance per phase: 3,6Ohm 7,2 Ohm Inductance per phase: 115mH 230mH Capacity per phase: Line-to-line: 2 x 150nF 300nF Line-to-ground: 2 x 0,55µF 1,1µF Max power consumption: 1kW Voltage: 3x 400V; 50/60Hz Current: 2A Inputs/outputs: 4mm safety sockets Dimensions: 297 x 456 x 125mm (HxWxD) Weight: 6kg. 2 Capacitive load, three-phase, 1kW CO3301-3E 1 Three groups of MP-capacitor, each consists four capacitors. for parallel, series, star and delta circuits capacity: 3 x 2/4/8/30 µf, 450 V Inputs/outputs: 4mm safety sockets Dimensions: 297 x 228 x 125mm (HxWxD) Weight: 3kg Lucas Nülle GmbH Page 6/118

7 3 Variable Ohmic load, three-phase, 1kW CO3301-3F 1 Three synchronously adjustable circular rheostats with scale 100-0%, each with a fuse in the sliding-contact connection. for parallel, series, star and delta circuits Resistance: 3 x 750 Ohm Current: 3 x 2 A Inputs/outputs: 4mm safety sockets Dimensions: 297 x 456 x 125mm (HxWxD) Weight: 8kg 4 Inductive load, three-phase, 1kW CO3301-3D 1 Consist of three inductive loads with the following taps: 1,2H (0,65A), 1,6H (0,5A), 2H (0,45A), 2,4H (0,35A), 2,8H (0,30A), 3,2H (0,25A) for parallel, series, star and delta circuits Inputs/outputs: 4mm safety sockets Dimensions: 297 x 456 x 125mm (HxWxD) Weight: 8kg 5 Power switch module CO3301-5P 1 The voltage can be switch on and off manually or automatically. Nominal voltage: V, 50/60Hz Control voltage: 24V Nominal operating current: 16A, ohmic Functions: 2 pushbutton switches and remote control for switch-off relay Indicators: signal lamps for "on" and "off" Contacts: 3 n.o. & 2 auxiliary Inputs/outputs: 4mm safety sockets Dimensions: 297 x 114 x 95mm (HxWxD) Weight: 2kg Lucas Nülle GmbH Page 7/118

8 Media: Pos. Product name Bestell-Nr. Anz. 6 Interactive Lab Assistant: High-voltage transmission lines SO2800-6K 1 The experiment instructions come in the form of an Interactive Lab Assistant course. This multimedia course is a step-by-step guide through the topic of modern energy systems. The fundamentals are conveyed using easy to understand animations. The Interactive Lab Assistant in conjunction with the SCADA Viewer constitutes a comfortable experimenting environment. Special features: Interactive experiment setups Measured values and diagrams can be stored in the experiment instructions per drag and drop The SCADA Viewer can be started directly from the experiment instructions Includes questions with feedback and evaluation logic for progress monitoring Documents can be printed out for hardcopy of experiment instructions including solutions CD-ROM with Labsoft browser, course software and SCADA Viewer Training contents: Studies of three-phase lines Voltage increases on open-circuit lines Voltage drop as a function of line length Voltage drop as a function of cos phi Capacitive and inductive power losses on a line as a function of V and I Phase shift on a line Parallel and series connection of transmission lines Distribution of power and current among parallelconnected lines of equal length Distribution of power and current among parallelconnected lines of unequal length Lucas Nülle GmbH Page 8/118

9 Distribution of power and current among series-connected lines of equal length Distribution of power and current among series-connected lines of unequal length Load distribution, power flow Voltage distribution Quantitative and qualitative evaluations of operational relationships Study of lines with earth-fault compensation Earth fault on a line with an isolated star point Response to earth faults Earth-fault compensation Studies on power transmission systems with synchronous generators Power and current distribution in a line network fed by a generator Parallel operation of a generator and line via the network Control of active power feed Control of reactive power feed Investigations on three phase cables Ferranti effect, charging capacity, critical length Resistive, inductive and resistive-inductive mixed loads Compensation for a resistive-inductive load Determining zero impedance Symmetric and asymmetric shorts Dealing with star points and shorts to earth Combined networks of cables and lines Differences between cables and transmission lines Investigation of connections: - Transmission lines, transformers and cables - Cables, transformers and transmission lines Losses from individual components Parameters for sub-stations Controlling flow of power in meshed networks Variable transformers Transformer with in-phase regulation (in-phase booster) Transformer with regulation in quadrature (quadrature booster) Phase-angle-regulating transformer (phase-shifting transformer) Affect flow of power via two identical conductors parallel to one another Course duration 22 h approx. Lucas Nülle GmbH Page 9/118

10 Software: Pos. Product name Bestell-Nr. Anz. 7 Software SCADA Viewer SO4001-3H 1 The 'SCADA Viewer' is a software program used for the control and monitoring of power engineering systems. With the software it is possible to display all measured values and operating states inside the system in real time on the existing measuring instruments. Important parameters and signals can be controlled by the software. The measured values and operating states of the equipment can be selected, recorded and plotted over time, evaluated and then exported. Using the 'SCADA Viewer' projects in power engineering are not only made transparent but readable. Software functions: Display of measured values and operating states in real time Plotting of measured values over time in diagrams Processing, analyzing and exporting of diagrams The SCADA viewer contains more than 20 predefined projects Many projects designed with the SCADA designer can be individually expanded at will 8 Patch cable Cat5E 1x 1m yellow, 2x 2m yellow LM x 1m yellow 2x 2m yellow Lucas Nülle GmbH Page 10/118

11 9 USB Network Adapter 10/100 BaseTX RJ45 LM USB-Ethernet adapter provides simple network access without having to install expansion card. The adapter is thus well-suited especially for cases where there are no more slots available in the PC or the housing should not be opened. This adapter is also an alternative for notebooks: instead of a PC card with an Ethernet port the adapter offers a universal connection option for all PCs with USB interface. USB 2.0 high-speed device Downward compatible with USB 1.1 and 1.0 Host controllers Compatible with IEEE 802.3u, 10/100 Base-T and TX Supports both full and half-duplex mode on Ethernet interface Operating systems: Windows ME/200/XP/Vista,7 (32+64 Bit), Linux, Mac OS 10.x 10 5-Port Ethernet Switch LM Port Ethernet Switch 5 RJ45 terminals Power supply Lucas Nülle GmbH Page 11/118

12 Power supply: Pos. Product name Bestell-Nr. Anz. 11 Adjustable 3-phase power supply, 0-450V/2A CO3301-3Z 1 Controllable 3-phase power supply unit /450V for continuous 3-phase supply Power connection: 230/400V, 50/60Hz Output voltage: 3x V, 50/60Hz variable by means of 3- phase regulating transformer (tolerance 0.5%) DC output V Output current: 2.0A 4-mm safety sockets (L1, L2, L3, N, PE, L-, L+) 1 Voltmeter, V (moving iron instrument) 1 Ammeter, 0...3A (moving iron instrument) 3 Phase control lights 1 Measuring point selector switch. L1-N, L2-N, L3-N, L1-L2, L1-L3, L2-L3 1 Measuring point selector switch. I1, I2, I3 Protection: 3 thermo-magnetic device circuit breakers, Motor protection switch adjustable from A with undervoltage trip Table-top housing with fold-away stand Dimensions: 175 x 370 x 260mm (HxWxD) Weight: 15kg 12 Multiple socket outlet, 6 fold, with illuminated switch ST8010-4J 2 Multiple socket outlet, 6 fold, with illuminated switch, 2 pole 6 earth pin sockets acoording to DIN49440, 250V~,16A power cord 1,5m Dimensions: 439 x 60 x 44mm (LxWxH) Lucas Nülle GmbH Page 12/118

13 Measuring instruments: Pos. Product name Bestell-Nr. Anz. 13 Three-phase power quality meter, display and long-term memory CO5127-1S 2 The three-phase measuring instrument permits the measurement and display of relevant power network parameters. It is able to measure single, two-phase or three-phase measurements. The display and operation is carried out by means of menu navigation with an LC display or the integrated Ethernet interface. The optional SCADA software provides for the display of all measurements and allows the implementation and analysis of intelligent networks (smart grids). The smart meter acts as a digital electricity meter where end customers are connected to the grid in order to measure electricity consumption and can be used to turn consumers on or off depending on the circumstances. Three-phase measurement of current and voltage 3x400V/5A Measurement of phase voltages, line-to-line voltages and currents Determination of the apparent, active and reactive power Determination of active, reactive and apparent work Determination of the frequency and distortion factors for current and voltage Detection of harmonic oscillations and neutral conductor current in the electricity supply Pulse measurement Peak and mean value detection Event logging Real-time clock Large-scale, contrast-rich graphic display with background illumination Display in tables, diagrams and vector diagrams 2 Digital inputs and outputs for free configuration including functions Ethernet interface Menu navigation in German/English/ French/Spanish/Italian/Portuguese/Turkish/ Chinese/Russian/Polish Demonstration measuring instrument for making measurements on the electricity supply grid Max. measurement values: Voltage P-P: 690 V Current: 5 A Fault tolerances: Voltage 0.2% Current 0.2% Apparent power 0.5% Active power 0.2% Reactive power 1% Active energy Class 0.2 Reactive energy Class 2 Operating voltage: 110V-230V, 50/60Hz Dimensions: 297 x 228 x 140mm (HxWxD) Weight: 2kg Lucas Nülle GmbH Page 13/118

14 Accessories: Pos. Product name Bestell-Nr. Anz. 14 Safety connecting plug 4mm with tap (2x), black, 1000V/32A CAT II SO5126-3R 40 Moulded insulation both sides with touch protection (safety plug + safety sockets), distance 19mm transition resistance max. 6mΩ rated data: 1000V/32A CAT II colour black 15 Safety connecting plug 4mm with tap (2x), blue, 1000V/32A CAT II SO5126-3V 2 Moulded insulation both sides with touch protection (safety plug + safety sockets), distance 19mm transition resistance max. 6mΩ rated data: 1000V/32A CAT II colour blue 16 Safety connecting plug 4mm with tap (2x), green/yellow, 1000V/32A CAT II SO5126-3W 7 Moulded insulation both sides with touch protection (safety plug + safety sockets), distance 19mm transition resistance max. 6mΩ rated data: 1000V/32A CAT II colour green/yellow Lucas Nülle GmbH Page 14/118

15 17 Set of safety measurement cables, 4mm (31 leads) SO5148-1L 1 Safety measurement cables with 4mm safety plugs, coloured, PVC insulation, highly flexible Each set includes the following: 6 x 25cm long, black 4 x 50cm long, black 2 x 100cm long, blue 2 x 100cm long, red 1 x 100cm long, green/yellow 1 x 150cm long, blue 1 x 150cm long, green/yellow 2 x 150cm long, green 4 x 150cm long, brown 4 x 150cm long, black 4 x 150cm long, grey Wire cross section 2.5 mm ² Capacity/category: 600V CAT II, 32A 18 Safety measurement cable (4mm), 50cm, black SO5126-8L 6 Safety measurement lead with stackable, contact-proof 4mm plugs Colour: black Length: 50 cm Wire cross section 2.5 mm 2 19 Safety measurement cable (4mm), 25cm/10", black SO5126-8B 3 Safety measurement lead with stackable, contact-proof 4mm plugs colour: black length: 25 cm cable cross-section 2,5 mm 2 ratings deliver: 600V CAT II, 32A Lucas Nülle GmbH Page 15/118

16 20 Mobile aluminium experiment stand, 3 levels, power strip with 6 sockets, 1250x700x1995mm ST7200-3A 1 High-quality, mobile experiments stand from the SybaPro range for demonstrations and experiments. Features aluminium profile legs compatible with all add-ons and extensions for the SybaPro system. The mobile experiment stand is supplied in kit form and needs to be assembled by customers themselves. Table top: Frame: Dimensions: 30-mm table top made of highly compressed, multi-layer fine chipboard conforming to DIN EN Colour grey, RAL 7035, with 0.8-mm slightly textured laminate coating (Resopal) on both sides, conforming to DIN Resistant to many chemicals and reagents including dilute acids and alkalis Resistant to heat, e.g. molten solder or heating at specific points such as by soldering tips or cigarette ends Table top with solid impact-resistant protective edging made of 3mm thick RAL 7047 coloured plastic Coating and adhesive are PVC free Power strip with 6 outlet sockets mounted underneath the table top, lead and earthed plug 2 extruded aluminium profiles with multiple grooves 1800 x 120 x 40 mm (WxHxD) 8 equally sized grooves in extruded aluminium profiles (3 on each side and 1 each on the front and back) Grooves accommodate standard industrial mountings 4 H-shaped aluminium profiles, 1150 mm, for 3-layer organisation of DIN A4 panels Space for extension of power supply duct Base made of rectangular tubing with 4 swiveling double casters, 2 of which have brakes Table frame made of tough combination of rectangular tubing around the full perimeter Acid-resistant epoxy-resin coating, 80 µm thick (approx.), colour RAL 7047 Height of table top 760 mm 1250 x 1995 x 700 mm (WxHxD) Lucas Nülle GmbH Page 16/118

17 21 Protected power distribution for working stations ST8008-8M V CEE distribution panel with automatic circuit breakers for attachment to profiles on experiment trolleys or direct to table-top. 2 CEE sockets (400 V, 16 A, 5-pole) with safety flap 1 Socket outlet with earth (230 V) plus safety flap Circuit breaker: 1 x 3-pole line circuit breaker, type B, 16 A Power connection: 3 x 230/400 V, 50/60 Hz via CEE plug, 4-m power lead Dimensions: 530 x 130 x 110 mm (HxWxD) Weight: 3 kg 22 Wall or aluminium-profile mounting cable storage for 48 cables ST8003-8E 1 Accommodates about 48 safety measuring leads (4mm), suitable for mounting on walls or aluminium profiles Width 200 mm, 12 guide grooves for leads Adjustable height for mounting on aluminium profiles Can be mounted on the left or right Can be mounted on walls Includes 2 screws and tenon blocks Acid-resistant epoxy-resin powder coating, thickness 80 µm approx., colour RAL PC holder for SybaPro experiment trolleys, height/width adjustable ST7200-5A 1 Shelf for desktop PC made of 1.5mm sheet steel punched with holes, suitable for all furniture in the SybaPro aluminium profile range Adjustable assembly height Adjustable width ( mm) Can be mounted to left or right Includes all equipment necessary for assembly (4 bolts and 4 tenon blocks) Acid-resistant epoxy-resin powder coating, 80µm thick approx., colour RAL7047 Lucas Nülle GmbH Page 17/118

18 24 Monitor holder for flat screen monitor of weight up to 15kg / 33lbs ST8010-4T 1 Pivoting monitor holder for attachment to aluminium profiles of furniture in the SybaPro range. Allows a monitor to be placed in the optimum position so that work and experiments are less tiring. Pivoting arm with two-part joint Quick-lock for adjustment to any height on extruded aluminium profile VESA fastening 7.5 x 7.5cm Includes VESA 75 (7.5x7.5) - VESA 100 (10x10) adapter 2 Cable clips Adequate carrying capacity 15kg / 33lbs TFT monitor can be turned parallel to the table edge Separation can be adjusted to anywhere between 105 and 480mm Additionally included: Cable management set for installing cables along the profiles of the aluminium lab system furniture in the SybaPro range, consisting of: 3 Cross cable binders for front and rear grooves of aluminium profile 3 Cross cable binders for side grooves of aluminium profile 12 Cable binders 4 Aluminium cover profiles for covering and enabling wires to be run along the grooves of an aluminium profile 25 Keyboard adapter for flat screen monitor holders ST8010-4G 1 Keyboard adapter for use in combination with flat screen monitor holders Mounted between monitor and mount for flat screen monitor holder Variable 3-level height adjustment via multiple pre-drilled mounting holes Two rows of mounting holes for use with equipment meeting VESA 75 and VESA 100 standards Keyboard shelf inclined by about 30 for comfortable and ergonomic usability Keyboard shelf with 11-mm folded edging to prevent falling, including handle Variable 2-level depth attachment for keyboard shelf (252/276 mm) Extra-wide keyboard shelf (640 mm) can accommodate a mouse as well Depth of keyboard shelf 172 mm Includes two cable clips for guiding and bundling cables Maximum load 10 kg Dimensions (HxWxD) 360 x 640 x 276 mm Lucas Nülle GmbH Page 18/118

19 26 Protection cover for three-level experiment trolleys ST8010-9Y 1 Dust cover for three-level experiment trolleys For protecting equipment from dust and damp For keeping equipment out of sight (the cover must not be transparent, so is therefore opaque) Colour: matt dark grey with printed LN logo in orange) Material: nylon fabric with polyurethane coating High resistant to tearing, impregnated to be washable and waterproof EUL 2 Parallel and series connection of transmission lines Lucas Nülle GmbH Page 19/118

20 EUL 2 Parallel and series connection of transmission lines Training contents: Distribution of power and current among parallel-connected lines of equal length Distribution of power and current among parallel-connected lines of unequal length Distribution of power and current among series-connected lines of equal length Distribution of power and current among series-connected lines of unequal length Load distribution, power flow Voltage distribution Quantitative and qualitative evaluations of operational relationships Supplement to basic set, consisting of: Supplement to basic set, consisting of: Pos. Product name Bestell-Nr. Anz. 27 Transmission line Model 150km/300km (93.2miles/186.4miles) CO3301-3A 1 Three-phase line simulation of a high voltage overhead power line with different lengths for measuring various operational states (open-line, matched, short-circuit). Scale factor 1/1000 for current and voltage. Automatic modification of wire length as soon as the corresponding overlay is in place. Transmission line length: 150km or 300km Transmission line length: 93.2 miles or miles Resistance per phase: 3,6Ohm 7,2 Ohm Inductance per phase: 115mH 230mH Capacity per phase: Line-to-line: 2 x 150nF 300nF Line-to-ground: 2 x 0,55µF 1,1µF Max power consumption: 1kW Voltage: 3x 400V; 50/60Hz Current: 2A Inputs/outputs: 4mm safety sockets Dimensions: 297 x 456 x 125mm (HxWxD) Weight: 6kg. Lucas Nülle GmbH Page 20/118

21 28 Digital/analog multimeter, wattmeter, power-factor incl. software CO5127-1Z 1 The areas of electrical machines, power electronics and drive technology pose particular problems for measuring instruments. In addition to high-performance overload protection, the acquisition of measurement values must be performed accurately independently of the curve's shape. The universal measuring device has been designed particularly to satisfy these requirements. It can simultaneously replace as many as four different measuring instruments constituting a current/voltmeter, power and phaseangle meter all in one. The graphic display allows for both student as well demonstration experiments. The VI Starter software included allows for visualisation of measurements on a PC. Simultaneous, measurement of voltage and current independent of the curve shape (max. 600 V, 20 A) (measurement of clocked voltages) Calculation of active, apparent and reactive power as well as the power factor Measurement of the total rms (RMS-AC+DC), AC rms (RMS- AC) and arithmetic mean (AV-AC+DC) Impervious to electrical damage up to 20 A/600 V Large-scale, high-contrast background-illuminated graphic display (5.7") Large-scale display or display of up to 4 measurement values Digital or pseudo-analog display USB interface Internal resistance: current path 10 mω, voltage path 10 MΩ Voltage ranges: 30, 300, 600 V Current ranges: 1, 10, 20 A Measurement accuracy: 2% Automatic or manual measurement range selection Demonstration test instrument for measuring properties of the electricity supply Operating voltage: 230V, 50/60Hz Dimensions: 297 x 228 x 140mm (HxBxT) Weight: 2kg The VI Starter software allows all the measurements to be displayed on the PC. Up to 17 different displays can be opened. Oscilloscope display of voltage, current and power Consumption meter to display power consumed and output Data logger for 14 different variables Data export for data logger Characteristic recorder Labview driver and supplied examples 32-bit version for Windows Media: Pos. Product name Bestell-Nr. Anz. Lucas Nülle GmbH Page 21/118

22 29 Interactive Lab Assistant: High-voltage transmission lines SO2800-6K 1 The experiment instructions come in the form of an Interactive Lab Assistant course. This multimedia course is a step-by-step guide through the topic of modern energy systems. The fundamentals are conveyed using easy to understand animations. The Interactive Lab Assistant in conjunction with the SCADA Viewer constitutes a comfortable experimenting environment. Special features: Interactive experiment setups Measured values and diagrams can be stored in the experiment instructions per drag and drop The SCADA Viewer can be started directly from the experiment instructions Includes questions with feedback and evaluation logic for progress monitoring Documents can be printed out for hardcopy of experiment instructions including solutions CD-ROM with Labsoft browser, course software and SCADA Viewer Training contents: Studies of three-phase lines Voltage increases on open-circuit lines Voltage drop as a function of line length Voltage drop as a function of cos phi Capacitive and inductive power losses on a line as a function of V and I Phase shift on a line Parallel and series connection of transmission lines Distribution of power and current among parallelconnected lines of equal length Distribution of power and current among parallelconnected lines of unequal length Distribution of power and current among series-connected lines of equal length Distribution of power and current among series-connected lines of unequal length Load distribution, power flow Voltage distribution Quantitative and qualitative evaluations of operational relationships Lucas Nülle GmbH Page 22/118

23 Study of lines with earth-fault compensation Earth fault on a line with an isolated star point Response to earth faults Earth-fault compensation Studies on power transmission systems with synchronous generators Power and current distribution in a line network fed by a generator Parallel operation of a generator and line via the network Control of active power feed Control of reactive power feed Investigations on three phase cables Ferranti effect, charging capacity, critical length Resistive, inductive and resistive-inductive mixed loads Compensation for a resistive-inductive load Determining zero impedance Symmetric and asymmetric shorts Dealing with star points and shorts to earth Combined networks of cables and lines Differences between cables and transmission lines Investigation of connections: - Transmission lines, transformers and cables - Cables, transformers and transmission lines Losses from individual components Parameters for sub-stations Controlling flow of power in meshed networks Variable transformers Transformer with in-phase regulation (in-phase booster) Transformer with regulation in quadrature (quadrature booster) Phase-angle-regulating transformer (phase-shifting transformer) Affect flow of power via two identical conductors parallel to one another Course duration 22 h approx. Lucas Nülle GmbH Page 23/118

24 Software: Pos. Product name Bestell-Nr. Anz. 30 Software SCADA Viewer SO4001-3H 1 The 'SCADA Viewer' is a software program used for the control and monitoring of power engineering systems. With the software it is possible to display all measured values and operating states inside the system in real time on the existing measuring instruments. Important parameters and signals can be controlled by the software. The measured values and operating states of the equipment can be selected, recorded and plotted over time, evaluated and then exported. Using the 'SCADA Viewer' projects in power engineering are not only made transparent but readable. Software functions: Display of measured values and operating states in real time Plotting of measured values over time in diagrams Processing, analyzing and exporting of diagrams The SCADA viewer contains more than 20 predefined projects Many projects designed with the SCADA designer can be individually expanded at will 31 Patch cable Cat5E 1x 1m yellow, 2x 2m yellow LM x 1m yellow 2x 2m yellow Lucas Nülle GmbH Page 24/118

25 32 USB Network Adapter 10/100 BaseTX RJ45 LM USB-Ethernet adapter provides simple network access without having to install expansion card. The adapter is thus well-suited especially for cases where there are no more slots available in the PC or the housing should not be opened. This adapter is also an alternative for notebooks: instead of a PC card with an Ethernet port the adapter offers a universal connection option for all PCs with USB interface. USB 2.0 high-speed device Downward compatible with USB 1.1 and 1.0 Host controllers Compatible with IEEE 802.3u, 10/100 Base-T and TX Supports both full and half-duplex mode on Ethernet interface Operating systems: Windows ME/200/XP/Vista,7 (32+64 Bit), Linux, Mac OS 10.x 33 5-Port Ethernet Switch LM Port Ethernet Switch 5 RJ45 terminals Power supply Lucas Nülle GmbH Page 25/118

26 Power supply: Pos. Product name Bestell-Nr. Anz. 34 Adjustable 3-phase power supply, 0-450V/2A CO3301-3Z 1 Controllable 3-phase power supply unit /450V for continuous 3-phase supply Power connection: 230/400V, 50/60Hz Output voltage: 3x V, 50/60Hz variable by means of 3- phase regulating transformer (tolerance 0.5%) DC output V Output current: 2.0A 4-mm safety sockets (L1, L2, L3, N, PE, L-, L+) 1 Voltmeter, V (moving iron instrument) 1 Ammeter, 0...3A (moving iron instrument) 3 Phase control lights 1 Measuring point selector switch. L1-N, L2-N, L3-N, L1-L2, L1-L3, L2-L3 1 Measuring point selector switch. I1, I2, I3 Protection: 3 thermo-magnetic device circuit breakers, Motor protection switch adjustable from A with undervoltage trip Table-top housing with fold-away stand Dimensions: 175 x 370 x 260mm (HxWxD) Weight: 15kg 35 Multiple socket outlet, 6 fold, with illuminated switch ST8010-4J 2 Multiple socket outlet, 6 fold, with illuminated switch, 2 pole 6 earth pin sockets acoording to DIN49440, 250V~,16A power cord 1,5m Dimensions: 439 x 60 x 44mm (LxWxH) Lucas Nülle GmbH Page 26/118

27 Measuring instruments: Pos. Product name Bestell-Nr. Anz. 36 Three-phase power quality meter, display and long-term memory CO5127-1S 2 The three-phase measuring instrument permits the measurement and display of relevant power network parameters. It is able to measure single, two-phase or three-phase measurements. The display and operation is carried out by means of menu navigation with an LC display or the integrated Ethernet interface. The optional SCADA software provides for the display of all measurements and allows the implementation and analysis of intelligent networks (smart grids). The smart meter acts as a digital electricity meter where end customers are connected to the grid in order to measure electricity consumption and can be used to turn consumers on or off depending on the circumstances. Three-phase measurement of current and voltage 3x400V/5A Measurement of phase voltages, line-to-line voltages and currents Determination of the apparent, active and reactive power Determination of active, reactive and apparent work Determination of the frequency and distortion factors for current and voltage Detection of harmonic oscillations and neutral conductor current in the electricity supply Pulse measurement Peak and mean value detection Event logging Real-time clock Large-scale, contrast-rich graphic display with background illumination Display in tables, diagrams and vector diagrams 2 Digital inputs and outputs for free configuration including functions Ethernet interface Menu navigation in German/English/ French/Spanish/Italian/Portuguese/Turkish/ Chinese/Russian/Polish Demonstration measuring instrument for making measurements on the electricity supply grid Max. measurement values: Voltage P-P: 690 V Current: 5 A Fault tolerances: Voltage 0.2% Current 0.2% Apparent power 0.5% Active power 0.2% Reactive power 1% Active energy Class 0.2 Reactive energy Class 2 Operating voltage: 110V-230V, 50/60Hz Dimensions: 297 x 228 x 140mm (HxWxD) Weight: 2kg Lucas Nülle GmbH Page 27/118

28 Accessories: Pos. Product name Bestell-Nr. Anz. 37 Safety connecting plug 4mm with tap (2x), black, 1000V/32A CAT II SO5126-3R 40 Moulded insulation both sides with touch protection (safety plug + safety sockets), distance 19mm transition resistance max. 6mΩ rated data: 1000V/32A CAT II colour black 38 Safety connecting plug 4mm with tap (2x), blue, 1000V/32A CAT II SO5126-3V 2 Moulded insulation both sides with touch protection (safety plug + safety sockets), distance 19mm transition resistance max. 6mΩ rated data: 1000V/32A CAT II colour blue 39 Safety connecting plug 4mm with tap (2x), green/yellow, 1000V/32A CAT II SO5126-3W 7 Moulded insulation both sides with touch protection (safety plug + safety sockets), distance 19mm transition resistance max. 6mΩ rated data: 1000V/32A CAT II colour green/yellow Lucas Nülle GmbH Page 28/118

29 40 Set of safety measurement cables, 4mm (31 leads) SO5148-1L 1 Safety measurement cables with 4mm safety plugs, coloured, PVC insulation, highly flexible Each set includes the following: 6 x 25cm long, black 4 x 50cm long, black 2 x 100cm long, blue 2 x 100cm long, red 1 x 100cm long, green/yellow 1 x 150cm long, blue 1 x 150cm long, green/yellow 2 x 150cm long, green 4 x 150cm long, brown 4 x 150cm long, black 4 x 150cm long, grey Wire cross section 2.5 mm ² Capacity/category: 600V CAT II, 32A 41 Safety measurement cable (4mm), 50cm, black SO5126-8L 6 Safety measurement lead with stackable, contact-proof 4mm plugs Colour: black Length: 50 cm Wire cross section 2.5 mm 2 42 Safety measurement cable (4mm), 25cm/10", black SO5126-8B 3 Safety measurement lead with stackable, contact-proof 4mm plugs colour: black length: 25 cm cable cross-section 2,5 mm 2 ratings deliver: 600V CAT II, 32A Lucas Nülle GmbH Page 29/118

30 43 Mobile aluminium experiment stand, 3 levels, power strip with 6 sockets, 1250x700x1995mm ST7200-3A 1 High-quality, mobile experiments stand from the SybaPro range for demonstrations and experiments. Features aluminium profile legs compatible with all add-ons and extensions for the SybaPro system. The mobile experiment stand is supplied in kit form and needs to be assembled by customers themselves. Table top: Frame: Dimensions: 30-mm table top made of highly compressed, multi-layer fine chipboard conforming to DIN EN Colour grey, RAL 7035, with 0.8-mm slightly textured laminate coating (Resopal) on both sides, conforming to DIN Resistant to many chemicals and reagents including dilute acids and alkalis Resistant to heat, e.g. molten solder or heating at specific points such as by soldering tips or cigarette ends Table top with solid impact-resistant protective edging made of 3mm thick RAL 7047 coloured plastic Coating and adhesive are PVC free Power strip with 6 outlet sockets mounted underneath the table top, lead and earthed plug 2 extruded aluminium profiles with multiple grooves 1800 x 120 x 40 mm (WxHxD) 8 equally sized grooves in extruded aluminium profiles (3 on each side and 1 each on the front and back) Grooves accommodate standard industrial mountings 4 H-shaped aluminium profiles, 1150 mm, for 3-layer organisation of DIN A4 panels Space for extension of power supply duct Base made of rectangular tubing with 4 swiveling double casters, 2 of which have brakes Table frame made of tough combination of rectangular tubing around the full perimeter Acid-resistant epoxy-resin coating, 80 µm thick (approx.), colour RAL 7047 Height of table top 760 mm 1250 x 1995 x 700 mm (WxHxD) Lucas Nülle GmbH Page 30/118

31 44 Protected power distribution for working stations ST8008-8M V CEE distribution panel with automatic circuit breakers for attachment to profiles on experiment trolleys or direct to table-top. 2 CEE sockets (400 V, 16 A, 5-pole) with safety flap 1 Socket outlet with earth (230 V) plus safety flap Circuit breaker: 1 x 3-pole line circuit breaker, type B, 16 A Power connection: 3 x 230/400 V, 50/60 Hz via CEE plug, 4-m power lead Dimensions: 530 x 130 x 110 mm (HxWxD) Weight: 3 kg 45 Wall or aluminium-profile mounting cable storage for 48 cables ST8003-8E 1 Accommodates about 48 safety measuring leads (4mm), suitable for mounting on walls or aluminium profiles Width 200 mm, 12 guide grooves for leads Adjustable height for mounting on aluminium profiles Can be mounted on the left or right Can be mounted on walls Includes 2 screws and tenon blocks Acid-resistant epoxy-resin powder coating, thickness 80 µm approx., colour RAL PC holder for SybaPro experiment trolleys, height/width adjustable ST7200-5A 1 Shelf for desktop PC made of 1.5mm sheet steel punched with holes, suitable for all furniture in the SybaPro aluminium profile range Adjustable assembly height Adjustable width ( mm) Can be mounted to left or right Includes all equipment necessary for assembly (4 bolts and 4 tenon blocks) Acid-resistant epoxy-resin powder coating, 80µm thick approx., colour RAL7047 Lucas Nülle GmbH Page 31/118

32 47 Monitor holder for flat screen monitor of weight up to 15kg / 33lbs ST8010-4T 1 Pivoting monitor holder for attachment to aluminium profiles of furniture in the SybaPro range. Allows a monitor to be placed in the optimum position so that work and experiments are less tiring. Pivoting arm with two-part joint Quick-lock for adjustment to any height on extruded aluminium profile VESA fastening 7.5 x 7.5cm Includes VESA 75 (7.5x7.5) - VESA 100 (10x10) adapter 2 Cable clips Adequate carrying capacity 15kg / 33lbs TFT monitor can be turned parallel to the table edge Separation can be adjusted to anywhere between 105 and 480mm Additionally included: Cable management set for installing cables along the profiles of the aluminium lab system furniture in the SybaPro range, consisting of: 3 Cross cable binders for front and rear grooves of aluminium profile 3 Cross cable binders for side grooves of aluminium profile 12 Cable binders 4 Aluminium cover profiles for covering and enabling wires to be run along the grooves of an aluminium profile 48 Keyboard adapter for flat screen monitor holders ST8010-4G 1 Keyboard adapter for use in combination with flat screen monitor holders Mounted between monitor and mount for flat screen monitor holder Variable 3-level height adjustment via multiple pre-drilled mounting holes Two rows of mounting holes for use with equipment meeting VESA 75 and VESA 100 standards Keyboard shelf inclined by about 30 for comfortable and ergonomic usability Keyboard shelf with 11-mm folded edging to prevent falling, including handle Variable 2-level depth attachment for keyboard shelf (252/276 mm) Extra-wide keyboard shelf (640 mm) can accommodate a mouse as well Depth of keyboard shelf 172 mm Includes two cable clips for guiding and bundling cables Maximum load 10 kg Dimensions (HxWxD) 360 x 640 x 276 mm Lucas Nülle GmbH Page 32/118

33 49 Protection cover for three-level experiment trolleys ST8010-9Y 1 Dust cover for three-level experiment trolleys For protecting equipment from dust and damp For keeping equipment out of sight (the cover must not be transparent, so is therefore opaque) Colour: matt dark grey with printed LN logo in orange) Material: nylon fabric with polyurethane coating High resistant to tearing, impregnated to be washable and waterproof EUL 3 Transmission Line with Earth-fault Compensation EUL 3 Transmission Line with Earth-fault Compensation Training contents: Earth fault on a line with an isolated star point Response to earth faults Earth-fault compensation Lucas Nülle GmbH Page 33/118

34 Supplement to basic set, consisting of: Supplement to basic set, consisting of: Pos. Product name Bestell-Nr. Anz. 50 Earth fault compensation unit CO3301-4X 1 This earth fault compensation unit is connected between the neutral line and the earth to compensate the capacitive earth-fault current by selecting the correct inductance. The unit can be adjusted to variable settings in order to facilitate matching of the earth-fault inductors to the various switching states of the power supply system. (Petersen coil) Nominal voltage: 230V Max. current: 0,5A Coil: 1.0 to 2.0H, 9 variable stages Inputs/outputs: 4mm safety sockets Dimensions: 297 x 228 x 120mm (HxWxD) Weight: 5kg Media: Pos. Product name Bestell-Nr. Anz. 51 Interactive Lab Assistant: High-voltage transmission lines SO2800-6K 1 The experiment instructions come in the form of an Interactive Lab Assistant course. This multimedia course is a step-by-step guide through the topic of modern energy systems. The fundamentals are conveyed using easy to understand animations. The Interactive Lab Assistant in conjunction with the SCADA Viewer constitutes a comfortable experimenting environment. Special features: Interactive experiment setups Measured values and diagrams can be stored in the experiment instructions per drag and drop Lucas Nülle GmbH Page 34/118

35 The SCADA Viewer can be started directly from the experiment instructions Includes questions with feedback and evaluation logic for progress monitoring Documents can be printed out for hardcopy of experiment instructions including solutions CD-ROM with Labsoft browser, course software and SCADA Viewer Training contents: Studies of three-phase lines Voltage increases on open-circuit lines Voltage drop as a function of line length Voltage drop as a function of cos phi Capacitive and inductive power losses on a line as a function of V and I Phase shift on a line Parallel and series connection of transmission lines Distribution of power and current among parallelconnected lines of equal length Distribution of power and current among parallelconnected lines of unequal length Distribution of power and current among series-connected lines of equal length Distribution of power and current among series-connected lines of unequal length Load distribution, power flow Voltage distribution Quantitative and qualitative evaluations of operational relationships Study of lines with earth-fault compensation Earth fault on a line with an isolated star point Response to earth faults Earth-fault compensation Studies on power transmission systems with synchronous generators Power and current distribution in a line network fed by a generator Parallel operation of a generator and line via the network Control of active power feed Lucas Nülle GmbH Page 35/118

36 Control of reactive power feed Investigations on three phase cables Ferranti effect, charging capacity, critical length Resistive, inductive and resistive-inductive mixed loads Compensation for a resistive-inductive load Determining zero impedance Symmetric and asymmetric shorts Dealing with star points and shorts to earth Combined networks of cables and lines Differences between cables and transmission lines Investigation of connections: - Transmission lines, transformers and cables - Cables, transformers and transmission lines Losses from individual components Parameters for sub-stations Controlling flow of power in meshed networks Variable transformers Transformer with in-phase regulation (in-phase booster) Transformer with regulation in quadrature (quadrature booster) Phase-angle-regulating transformer (phase-shifting transformer) Affect flow of power via two identical conductors parallel to one another Course duration 22 h approx. Lucas Nülle GmbH Page 36/118

37 Software: Pos. Product name Bestell-Nr. Anz. 52 Software SCADA Viewer SO4001-3H 1 The 'SCADA Viewer' is a software program used for the control and monitoring of power engineering systems. With the software it is possible to display all measured values and operating states inside the system in real time on the existing measuring instruments. Important parameters and signals can be controlled by the software. The measured values and operating states of the equipment can be selected, recorded and plotted over time, evaluated and then exported. Using the 'SCADA Viewer' projects in power engineering are not only made transparent but readable. Software functions: Display of measured values and operating states in real time Plotting of measured values over time in diagrams Processing, analyzing and exporting of diagrams The SCADA viewer contains more than 20 predefined projects Many projects designed with the SCADA designer can be individually expanded at will 53 Patch cable Cat5E 1x 1m yellow, 2x 2m yellow LM x 1m yellow 2x 2m yellow Lucas Nülle GmbH Page 37/118

38 54 USB Network Adapter 10/100 BaseTX RJ45 LM USB-Ethernet adapter provides simple network access without having to install expansion card. The adapter is thus well-suited especially for cases where there are no more slots available in the PC or the housing should not be opened. This adapter is also an alternative for notebooks: instead of a PC card with an Ethernet port the adapter offers a universal connection option for all PCs with USB interface. USB 2.0 high-speed device Downward compatible with USB 1.1 and 1.0 Host controllers Compatible with IEEE 802.3u, 10/100 Base-T and TX Supports both full and half-duplex mode on Ethernet interface Operating systems: Windows ME/200/XP/Vista,7 (32+64 Bit), Linux, Mac OS 10.x 55 5-Port Ethernet Switch LM Port Ethernet Switch 5 RJ45 terminals Power supply Lucas Nülle GmbH Page 38/118

39 Power supply: Pos. Product name Bestell-Nr. Anz. 56 Adjustable 3-phase power supply, 0-450V/2A CO3301-3Z 1 Controllable 3-phase power supply unit /450V for continuous 3-phase supply Power connection: 230/400V, 50/60Hz Output voltage: 3x V, 50/60Hz variable by means of 3- phase regulating transformer (tolerance 0.5%) DC output V Output current: 2.0A 4-mm safety sockets (L1, L2, L3, N, PE, L-, L+) 1 Voltmeter, V (moving iron instrument) 1 Ammeter, 0...3A (moving iron instrument) 3 Phase control lights 1 Measuring point selector switch. L1-N, L2-N, L3-N, L1-L2, L1-L3, L2-L3 1 Measuring point selector switch. I1, I2, I3 Protection: 3 thermo-magnetic device circuit breakers, Motor protection switch adjustable from A with undervoltage trip Table-top housing with fold-away stand Dimensions: 175 x 370 x 260mm (HxWxD) Weight: 15kg 57 Multiple socket outlet, 6 fold, with illuminated switch ST8010-4J 2 Multiple socket outlet, 6 fold, with illuminated switch, 2 pole 6 earth pin sockets acoording to DIN49440, 250V~,16A power cord 1,5m Dimensions: 439 x 60 x 44mm (LxWxH) Lucas Nülle GmbH Page 39/118

40 Measuring instruments: Pos. Product name Bestell-Nr. Anz. 58 Three-phase power quality meter, display and long-term memory CO5127-1S 2 The three-phase measuring instrument permits the measurement and display of relevant power network parameters. It is able to measure single, two-phase or three-phase measurements. The display and operation is carried out by means of menu navigation with an LC display or the integrated Ethernet interface. The optional SCADA software provides for the display of all measurements and allows the implementation and analysis of intelligent networks (smart grids). The smart meter acts as a digital electricity meter where end customers are connected to the grid in order to measure electricity consumption and can be used to turn consumers on or off depending on the circumstances. Three-phase measurement of current and voltage 3x400V/5A Measurement of phase voltages, line-to-line voltages and currents Determination of the apparent, active and reactive power Determination of active, reactive and apparent work Determination of the frequency and distortion factors for current and voltage Detection of harmonic oscillations and neutral conductor current in the electricity supply Pulse measurement Peak and mean value detection Event logging Real-time clock Large-scale, contrast-rich graphic display with background illumination Display in tables, diagrams and vector diagrams 2 Digital inputs and outputs for free configuration including functions Ethernet interface Menu navigation in German/English/ French/Spanish/Italian/Portuguese/Turkish/ Chinese/Russian/Polish Demonstration measuring instrument for making measurements on the electricity supply grid Max. measurement values: Voltage P-P: 690 V Current: 5 A Fault tolerances: Voltage 0.2% Current 0.2% Apparent power 0.5% Active power 0.2% Reactive power 1% Active energy Class 0.2 Reactive energy Class 2 Operating voltage: 110V-230V, 50/60Hz Dimensions: 297 x 228 x 140mm (HxWxD) Weight: 2kg Lucas Nülle GmbH Page 40/118

41 Accessories: Pos. Product name Bestell-Nr. Anz. 59 Safety connecting plug 4mm with tap (2x), black, 1000V/32A CAT II SO5126-3R 40 Moulded insulation both sides with touch protection (safety plug + safety sockets), distance 19mm transition resistance max. 6mΩ rated data: 1000V/32A CAT II colour black 60 Safety connecting plug 4mm with tap (2x), blue, 1000V/32A CAT II SO5126-3V 2 Moulded insulation both sides with touch protection (safety plug + safety sockets), distance 19mm transition resistance max. 6mΩ rated data: 1000V/32A CAT II colour blue 61 Safety connecting plug 4mm with tap (2x), green/yellow, 1000V/32A CAT II SO5126-3W 7 Moulded insulation both sides with touch protection (safety plug + safety sockets), distance 19mm transition resistance max. 6mΩ rated data: 1000V/32A CAT II colour green/yellow Lucas Nülle GmbH Page 41/118

42 62 Set of safety measurement cables, 4mm (31 leads) SO5148-1L 1 Safety measurement cables with 4mm safety plugs, coloured, PVC insulation, highly flexible Each set includes the following: 6 x 25cm long, black 4 x 50cm long, black 2 x 100cm long, blue 2 x 100cm long, red 1 x 100cm long, green/yellow 1 x 150cm long, blue 1 x 150cm long, green/yellow 2 x 150cm long, green 4 x 150cm long, brown 4 x 150cm long, black 4 x 150cm long, grey Wire cross section 2.5 mm ² Capacity/category: 600V CAT II, 32A 63 Safety measurement cable (4mm), 50cm, black SO5126-8L 6 Safety measurement lead with stackable, contact-proof 4mm plugs Colour: black Length: 50 cm Wire cross section 2.5 mm 2 64 Safety measurement cable (4mm), 25cm/10", black SO5126-8B 3 Safety measurement lead with stackable, contact-proof 4mm plugs colour: black length: 25 cm cable cross-section 2,5 mm 2 ratings deliver: 600V CAT II, 32A Lucas Nülle GmbH Page 42/118

43 65 Mobile aluminium experiment stand, 3 levels, power strip with 6 sockets, 1250x700x1995mm ST7200-3A 1 High-quality, mobile experiments stand from the SybaPro range for demonstrations and experiments. Features aluminium profile legs compatible with all add-ons and extensions for the SybaPro system. The mobile experiment stand is supplied in kit form and needs to be assembled by customers themselves. Table top: Frame: Dimensions: 30-mm table top made of highly compressed, multi-layer fine chipboard conforming to DIN EN Colour grey, RAL 7035, with 0.8-mm slightly textured laminate coating (Resopal) on both sides, conforming to DIN Resistant to many chemicals and reagents including dilute acids and alkalis Resistant to heat, e.g. molten solder or heating at specific points such as by soldering tips or cigarette ends Table top with solid impact-resistant protective edging made of 3mm thick RAL 7047 coloured plastic Coating and adhesive are PVC free Power strip with 6 outlet sockets mounted underneath the table top, lead and earthed plug 2 extruded aluminium profiles with multiple grooves 1800 x 120 x 40 mm (WxHxD) 8 equally sized grooves in extruded aluminium profiles (3 on each side and 1 each on the front and back) Grooves accommodate standard industrial mountings 4 H-shaped aluminium profiles, 1150 mm, for 3-layer organisation of DIN A4 panels Space for extension of power supply duct Base made of rectangular tubing with 4 swiveling double casters, 2 of which have brakes Table frame made of tough combination of rectangular tubing around the full perimeter Acid-resistant epoxy-resin coating, 80 µm thick (approx.), colour RAL 7047 Height of table top 760 mm 1250 x 1995 x 700 mm (WxHxD) Lucas Nülle GmbH Page 43/118

44 66 Protected power distribution for working stations ST8008-8M V CEE distribution panel with automatic circuit breakers for attachment to profiles on experiment trolleys or direct to table-top. 2 CEE sockets (400 V, 16 A, 5-pole) with safety flap 1 Socket outlet with earth (230 V) plus safety flap Circuit breaker: 1 x 3-pole line circuit breaker, type B, 16 A Power connection: 3 x 230/400 V, 50/60 Hz via CEE plug, 4-m power lead Dimensions: 530 x 130 x 110 mm (HxWxD) Weight: 3 kg 67 Wall or aluminium-profile mounting cable storage for 48 cables ST8003-8E 1 Accommodates about 48 safety measuring leads (4mm), suitable for mounting on walls or aluminium profiles Width 200 mm, 12 guide grooves for leads Adjustable height for mounting on aluminium profiles Can be mounted on the left or right Can be mounted on walls Includes 2 screws and tenon blocks Acid-resistant epoxy-resin powder coating, thickness 80 µm approx., colour RAL PC holder for SybaPro experiment trolleys, height/width adjustable ST7200-5A 1 Shelf for desktop PC made of 1.5mm sheet steel punched with holes, suitable for all furniture in the SybaPro aluminium profile range Adjustable assembly height Adjustable width ( mm) Can be mounted to left or right Includes all equipment necessary for assembly (4 bolts and 4 tenon blocks) Acid-resistant epoxy-resin powder coating, 80µm thick approx., colour RAL7047 Lucas Nülle GmbH Page 44/118

45 69 Monitor holder for flat screen monitor of weight up to 15kg / 33lbs ST8010-4T 1 Pivoting monitor holder for attachment to aluminium profiles of furniture in the SybaPro range. Allows a monitor to be placed in the optimum position so that work and experiments are less tiring. Pivoting arm with two-part joint Quick-lock for adjustment to any height on extruded aluminium profile VESA fastening 7.5 x 7.5cm Includes VESA 75 (7.5x7.5) - VESA 100 (10x10) adapter 2 Cable clips Adequate carrying capacity 15kg / 33lbs TFT monitor can be turned parallel to the table edge Separation can be adjusted to anywhere between 105 and 480mm Additionally included: Cable management set for installing cables along the profiles of the aluminium lab system furniture in the SybaPro range, consisting of: 3 Cross cable binders for front and rear grooves of aluminium profile 3 Cross cable binders for side grooves of aluminium profile 12 Cable binders 4 Aluminium cover profiles for covering and enabling wires to be run along the grooves of an aluminium profile 70 Keyboard adapter for flat screen monitor holders ST8010-4G 1 Keyboard adapter for use in combination with flat screen monitor holders Mounted between monitor and mount for flat screen monitor holder Variable 3-level height adjustment via multiple pre-drilled mounting holes Two rows of mounting holes for use with equipment meeting VESA 75 and VESA 100 standards Keyboard shelf inclined by about 30 for comfortable and ergonomic usability Keyboard shelf with 11-mm folded edging to prevent falling, including handle Variable 2-level depth attachment for keyboard shelf (252/276 mm) Extra-wide keyboard shelf (640 mm) can accommodate a mouse as well Depth of keyboard shelf 172 mm Includes two cable clips for guiding and bundling cables Maximum load 10 kg Dimensions (HxWxD) 360 x 640 x 276 mm Lucas Nülle GmbH Page 45/118

46 71 Protection cover for three-level experiment trolleys ST8010-9Y 1 Dust cover for three-level experiment trolleys For protecting equipment from dust and damp For keeping equipment out of sight (the cover must not be transparent, so is therefore opaque) Colour: matt dark grey with printed LN logo in orange) Material: nylon fabric with polyurethane coating High resistant to tearing, impregnated to be washable and waterproof EUL 4 Transmission Systems with a Synchronous Generator EUL 4 Transmission Systems with a Synchronous Generator Training contents: Power and current distribution in a line network fed by a generator Parallel operation of a generator and line via the network Control of active power feed Control of reactive power feed Lucas Nülle GmbH Page 46/118

47 Supplement to basic set, consisting of: Supplement to basic set, consisting of: Pos. Product name Bestell-Nr. Anz. 72 Exciter voltage controller with de-excitation CO3301-5G 1 The exciter voltage controller is used in experiments involving synchronisation. The de-excitation switch is used in generator protection measures and is responsible for the disconnection of the generator from the grid and its de-excitation in the event of a fault. Output: DC 200 V/2 A 2 Inputs for voltage boosting and decreasing 1 Input for de-excitation using a relay 1 Input for switching the DC voltage on 2 Push-buttons for switching the DC voltage on and off Incremental rotary encoder for setting the voltage Inputs and outputs: 4-mm safety sockets Power supply: 230 V, 50/60 Hz Dimensions: 297 x 228 x 190 mm (HxWxD) Weight: 5 kg 73 Synchronization Unit CO3212-6V 1 The Synchronization Unit consist of: synchroniser display (comprising 3 lamps) is used to display voltage and phase angles between generator and power supply circuit (light-dark indication) zero voltmeter double frequency meter double voltmeter digital Synchronoscope synchronization switch Operating voltage: 400V Dimensions: 297 x 452 x 125mm (HxWxD) Weight: 2kg Lucas Nülle GmbH Page 47/118

48 74 Three-phase synchronous machine with smooth core rotor, 1kW SE2662-5Q 1 Nominal voltage: 400/230V, 50Hz Nominal currrent: 1.5A / 2.6A Nominal speed: 1500rpm Nominal power: 0.8kW Cos phi: Exciter voltage: 220V Exciter current: 1.6A Dimensions: 500 x 220 x 250 mm (WxHxD) Weight: 20kg Additionally required - Machine test bench equipment set for servo-drive/braking system: Pos. Product name Bestell-Nr. Anz. 75 Servo machine test bench for 1kW machines incl. ActiveServo software(d,gb,f,e) CO3636-6W 1 Lucas Nülle GmbH Page 48/118

49 The servo-machine test bench is a complete testing system for examining electrical machines and drives. It consists of a digital controller, a brake and the AktiveServo software. The system combines state-of-the-art technology with ease of operation. The system also allows manual and automated synchronisation to be carried out. The controller has the following features: Dynamic and static four-quadrant operation 10 selectable operating modes/machine models (torque control, speed control, flywheel, lifting drive, roller/calander, fan, compressor, winding gear, arbitrarily defined timedependent load, manual and automated network synchronisation) Integrated galvanically isolated amplifier for voltage and current measurement Speed and torque displays Four-quadrant monitor USB interface Thermal monitoring of the machine under test Testing for the presence of a shaft cover. Connection voltage: 400V, 50Hz Maximum power output: 10kVA Dimensions: 297 x 460 x 420mm (HxWxD) Lucas Nülle GmbH Page 49/118

50 Weight: 14.3kg The brake is self-cooled asynchronous servo-brake with resolver. The motor and sensor leads are connected via polarity-safe plugs. The machine has thermal monitoring and, in conjunction with the controller, it constitutes a driving and braking system that is free of drift and requires no calibration. Maximum speed: 4000rpm Maximum torque 30Nm Temperature monitoring: continuous temperature sensor (KTY) Resolver resolution: pulses/revolution Dimensions: 275 x 210 x 210mm (WxHxD) Weight: 6kg ActiveServo is a program for recording characteristics of machines and for determining dynamic and static operating points. It emulates seven different loads (flywheel, pump, calander, lifting drive, compressor, winding gear, arbitrarily configurable time-dependent load) for which the parameters can be individually configured. Features: Measurement, calculation and display of mechanical and electrical variables (Speed, torque, mechanical power output, current, voltage, active, apparent and reactive power, efficiency, power factor) Simultaneous display of measured and calculated values (e.g. instant display of efficiency) Measurement of voltage and current (including RMS values even for non-sinusoidal waveforms) Speed or torque-controlled operation Recording of variables over time Programming of limiting values of speed or torque to prevent inappropriate loading of the machine under test. Operation in all four quadrants (display of generated torque) Arbitrarily defined ramp functions for PC-controlled load experiments Display of characteristics from several experiments to better illustrate the effect of parameter changes Export of graphics and measurements 32-bit version for Windows Lucas Nülle GmbH Page 50/118

51 76 Rubber coupling sleeve, 1kW SE2662-6A 1 Rubber coupling sleeve for the coupling of two machines. Permits rapid and safe assembly Designed with internal ring gear Material: rubber (neoprene) Dimensions: 40 x 58 mm (length x diameter) Weight: 0.1kg 77 Coupling guard, 1kW SE2662-6B 1 Attachable metal guard used to protect against accidental physical contact with the coupling location where rotation occurs between two connected machines. Material: black steel plating, folded with function plug Dimensions: 140 x 75 x 80mm (HxWxD) Weight: 0.1kg 78 Shaft end guard, 1kW SE2662-6C 1 Attachable metal guard used to protect against accidental physical contact with machine's rotating shafts. Material: black steel plate, folded, closed at the sides with drilled panel and function plug Dimensions: 140 x 75 x 40mm (HxWxD) Weight: 0.18kg 79 QuickChart, Servo-machine test stand safety and operating instructions (GB) SO6200-7D 1 Short documentation covering the putting into operation of complex equipment and experiment set-ups. Terminal assignment, safety instructions, help Circuit and assembly diagrams Color print in DIN A3 format Laminated: 2 x 250 µm Lucas Nülle GmbH Page 51/118

52 Media: Pos. Product name Bestell-Nr. Anz. 80 Interactive Lab Assistant: High-voltage transmission lines SO2800-6K 1 The experiment instructions come in the form of an Interactive Lab Assistant course. This multimedia course is a step-by-step guide through the topic of modern energy systems. The fundamentals are conveyed using easy to understand animations. The Interactive Lab Assistant in conjunction with the SCADA Viewer constitutes a comfortable experimenting environment. Special features: Interactive experiment setups Measured values and diagrams can be stored in the experiment instructions per drag and drop The SCADA Viewer can be started directly from the experiment instructions Includes questions with feedback and evaluation logic for progress monitoring Documents can be printed out for hardcopy of experiment instructions including solutions CD-ROM with Labsoft browser, course software and SCADA Viewer Training contents: Studies of three-phase lines Voltage increases on open-circuit lines Voltage drop as a function of line length Voltage drop as a function of cos phi Capacitive and inductive power losses on a line as a function of V and I Phase shift on a line Parallel and series connection of transmission lines Distribution of power and current among parallelconnected lines of equal length Distribution of power and current among parallelconnected lines of unequal length Distribution of power and current among series-connected lines of equal length Distribution of power and current among series-connected Lucas Nülle GmbH Page 52/118

53 lines of unequal length Load distribution, power flow Voltage distribution Quantitative and qualitative evaluations of operational relationships Study of lines with earth-fault compensation Earth fault on a line with an isolated star point Response to earth faults Earth-fault compensation Studies on power transmission systems with synchronous generators Power and current distribution in a line network fed by a generator Parallel operation of a generator and line via the network Control of active power feed Control of reactive power feed Investigations on three phase cables Ferranti effect, charging capacity, critical length Resistive, inductive and resistive-inductive mixed loads Compensation for a resistive-inductive load Determining zero impedance Symmetric and asymmetric shorts Dealing with star points and shorts to earth Combined networks of cables and lines Differences between cables and transmission lines Investigation of connections: - Transmission lines, transformers and cables - Cables, transformers and transmission lines Losses from individual components Parameters for sub-stations Controlling flow of power in meshed networks Variable transformers Transformer with in-phase regulation (in-phase booster) Transformer with regulation in quadrature (quadrature booster) Phase-angle-regulating transformer (phase-shifting transformer) Affect flow of power via two identical conductors parallel to one another Course duration 22 h approx. Lucas Nülle GmbH Page 53/118

54 Software: Pos. Product name Bestell-Nr. Anz. 81 Software SCADA Viewer SO4001-3H 1 The 'SCADA Viewer' is a software program used for the control and monitoring of power engineering systems. With the software it is possible to display all measured values and operating states inside the system in real time on the existing measuring instruments. Important parameters and signals can be controlled by the software. The measured values and operating states of the equipment can be selected, recorded and plotted over time, evaluated and then exported. Using the 'SCADA Viewer' projects in power engineering are not only made transparent but readable. Software functions: Display of measured values and operating states in real time Plotting of measured values over time in diagrams Processing, analyzing and exporting of diagrams The SCADA viewer contains more than 20 predefined projects Many projects designed with the SCADA designer can be individually expanded at will 82 Patch cable Cat5E 1x 1m yellow, 2x 2m yellow LM x 1m yellow 2x 2m yellow Lucas Nülle GmbH Page 54/118

55 83 USB Network Adapter 10/100 BaseTX RJ45 LM USB-Ethernet adapter provides simple network access without having to install expansion card. The adapter is thus well-suited especially for cases where there are no more slots available in the PC or the housing should not be opened. This adapter is also an alternative for notebooks: instead of a PC card with an Ethernet port the adapter offers a universal connection option for all PCs with USB interface. USB 2.0 high-speed device Downward compatible with USB 1.1 and 1.0 Host controllers Compatible with IEEE 802.3u, 10/100 Base-T and TX Supports both full and half-duplex mode on Ethernet interface Operating systems: Windows ME/200/XP/Vista,7 (32+64 Bit), Linux, Mac OS 10.x 84 5-Port Ethernet Switch LM Port Ethernet Switch 5 RJ45 terminals Power supply Lucas Nülle GmbH Page 55/118

56 Power supply: Pos. Product name Bestell-Nr. Anz. 85 Adjustable 3-phase power supply, 0-450V/2A CO3301-3Z 1 Controllable 3-phase power supply unit /450V for continuous 3-phase supply Power connection: 230/400V, 50/60Hz Output voltage: 3x V, 50/60Hz variable by means of 3- phase regulating transformer (tolerance 0.5%) DC output V Output current: 2.0A 4-mm safety sockets (L1, L2, L3, N, PE, L-, L+) 1 Voltmeter, V (moving iron instrument) 1 Ammeter, 0...3A (moving iron instrument) 3 Phase control lights 1 Measuring point selector switch. L1-N, L2-N, L3-N, L1-L2, L1-L3, L2-L3 1 Measuring point selector switch. I1, I2, I3 Protection: 3 thermo-magnetic device circuit breakers, Motor protection switch adjustable from A with undervoltage trip Table-top housing with fold-away stand Dimensions: 175 x 370 x 260mm (HxWxD) Weight: 15kg 86 Multiple socket outlet, 6 fold, with illuminated switch ST8010-4J 2 Multiple socket outlet, 6 fold, with illuminated switch, 2 pole 6 earth pin sockets acoording to DIN49440, 250V~,16A power cord 1,5m Dimensions: 439 x 60 x 44mm (LxWxH) Lucas Nülle GmbH Page 56/118

57 Measuring instruments: Pos. Product name Bestell-Nr. Anz. 87 Three-phase power quality meter, display and long-term memory CO5127-1S 2 The three-phase measuring instrument permits the measurement and display of relevant power network parameters. It is able to measure single, two-phase or three-phase measurements. The display and operation is carried out by means of menu navigation with an LC display or the integrated Ethernet interface. The optional SCADA software provides for the display of all measurements and allows the implementation and analysis of intelligent networks (smart grids). The smart meter acts as a digital electricity meter where end customers are connected to the grid in order to measure electricity consumption and can be used to turn consumers on or off depending on the circumstances. Three-phase measurement of current and voltage 3x400V/5A Measurement of phase voltages, line-to-line voltages and currents Determination of the apparent, active and reactive power Determination of active, reactive and apparent work Determination of the frequency and distortion factors for current and voltage Detection of harmonic oscillations and neutral conductor current in the electricity supply Pulse measurement Peak and mean value detection Event logging Real-time clock Large-scale, contrast-rich graphic display with background illumination Display in tables, diagrams and vector diagrams 2 Digital inputs and outputs for free configuration including functions Ethernet interface Menu navigation in German/English/ French/Spanish/Italian/Portuguese/Turkish/ Chinese/Russian/Polish Demonstration measuring instrument for making measurements on the electricity supply grid Max. measurement values: Voltage P-P: 690 V Current: 5 A Fault tolerances: Voltage 0.2% Current 0.2% Apparent power 0.5% Active power 0.2% Reactive power 1% Active energy Class 0.2 Reactive energy Class 2 Operating voltage: 110V-230V, 50/60Hz Dimensions: 297 x 228 x 140mm (HxWxD) Weight: 2kg Lucas Nülle GmbH Page 57/118

58 Accessories: Pos. Product name Bestell-Nr. Anz. 88 Safety connecting plug 4mm with tap (2x), black, 1000V/32A CAT II SO5126-3R 40 Moulded insulation both sides with touch protection (safety plug + safety sockets), distance 19mm transition resistance max. 6mΩ rated data: 1000V/32A CAT II colour black 89 Safety connecting plug 4mm with tap (2x), blue, 1000V/32A CAT II SO5126-3V 2 Moulded insulation both sides with touch protection (safety plug + safety sockets), distance 19mm transition resistance max. 6mΩ rated data: 1000V/32A CAT II colour blue 90 Safety connecting plug 4mm with tap (2x), green/yellow, 1000V/32A CAT II SO5126-3W 7 Moulded insulation both sides with touch protection (safety plug + safety sockets), distance 19mm transition resistance max. 6mΩ rated data: 1000V/32A CAT II colour green/yellow Lucas Nülle GmbH Page 58/118

59 91 Set of safety measurement cables, 4mm (31 leads) SO5148-1L 1 Safety measurement cables with 4mm safety plugs, coloured, PVC insulation, highly flexible Each set includes the following: 6 x 25cm long, black 4 x 50cm long, black 2 x 100cm long, blue 2 x 100cm long, red 1 x 100cm long, green/yellow 1 x 150cm long, blue 1 x 150cm long, green/yellow 2 x 150cm long, green 4 x 150cm long, brown 4 x 150cm long, black 4 x 150cm long, grey Wire cross section 2.5 mm ² Capacity/category: 600V CAT II, 32A 92 Safety measurement cable (4mm), 50cm, black SO5126-8L 6 Safety measurement lead with stackable, contact-proof 4mm plugs Colour: black Length: 50 cm Wire cross section 2.5 mm 2 93 Safety measurement cable (4mm), 25cm/10", black SO5126-8B 3 Safety measurement lead with stackable, contact-proof 4mm plugs colour: black length: 25 cm cable cross-section 2,5 mm 2 ratings deliver: 600V CAT II, 32A Lucas Nülle GmbH Page 59/118

60 94 Mobile aluminium experiment stand, 3 levels, power strip with 6 sockets, 1250x700x1995mm ST7200-3A 1 High-quality, mobile experiments stand from the SybaPro range for demonstrations and experiments. Features aluminium profile legs compatible with all add-ons and extensions for the SybaPro system. The mobile experiment stand is supplied in kit form and needs to be assembled by customers themselves. Table top: Frame: Dimensions: 30-mm table top made of highly compressed, multi-layer fine chipboard conforming to DIN EN Colour grey, RAL 7035, with 0.8-mm slightly textured laminate coating (Resopal) on both sides, conforming to DIN Resistant to many chemicals and reagents including dilute acids and alkalis Resistant to heat, e.g. molten solder or heating at specific points such as by soldering tips or cigarette ends Table top with solid impact-resistant protective edging made of 3mm thick RAL 7047 coloured plastic Coating and adhesive are PVC free Power strip with 6 outlet sockets mounted underneath the table top, lead and earthed plug 2 extruded aluminium profiles with multiple grooves 1800 x 120 x 40 mm (WxHxD) 8 equally sized grooves in extruded aluminium profiles (3 on each side and 1 each on the front and back) Grooves accommodate standard industrial mountings 4 H-shaped aluminium profiles, 1150 mm, for 3-layer organisation of DIN A4 panels Space for extension of power supply duct Base made of rectangular tubing with 4 swiveling double casters, 2 of which have brakes Table frame made of tough combination of rectangular tubing around the full perimeter Acid-resistant epoxy-resin coating, 80 µm thick (approx.), colour RAL 7047 Height of table top 760 mm 1250 x 1995 x 700 mm (WxHxD) Lucas Nülle GmbH Page 60/118

61 95 Protected power distribution for working stations ST8008-8M V CEE distribution panel with automatic circuit breakers for attachment to profiles on experiment trolleys or direct to table-top. 2 CEE sockets (400 V, 16 A, 5-pole) with safety flap 1 Socket outlet with earth (230 V) plus safety flap Circuit breaker: 1 x 3-pole line circuit breaker, type B, 16 A Power connection: 3 x 230/400 V, 50/60 Hz via CEE plug, 4-m power lead Dimensions: 530 x 130 x 110 mm (HxWxD) Weight: 3 kg 96 Wall or aluminium-profile mounting cable storage for 48 cables ST8003-8E 1 Accommodates about 48 safety measuring leads (4mm), suitable for mounting on walls or aluminium profiles Width 200 mm, 12 guide grooves for leads Adjustable height for mounting on aluminium profiles Can be mounted on the left or right Can be mounted on walls Includes 2 screws and tenon blocks Acid-resistant epoxy-resin powder coating, thickness 80 µm approx., colour RAL PC holder for SybaPro experiment trolleys, height/width adjustable ST7200-5A 1 Shelf for desktop PC made of 1.5mm sheet steel punched with holes, suitable for all furniture in the SybaPro aluminium profile range Adjustable assembly height Adjustable width ( mm) Can be mounted to left or right Includes all equipment necessary for assembly (4 bolts and 4 tenon blocks) Acid-resistant epoxy-resin powder coating, 80µm thick approx., colour RAL7047 Lucas Nülle GmbH Page 61/118

62 98 Monitor holder for flat screen monitor of weight up to 15kg / 33lbs ST8010-4T 1 Pivoting monitor holder for attachment to aluminium profiles of furniture in the SybaPro range. Allows a monitor to be placed in the optimum position so that work and experiments are less tiring. Pivoting arm with two-part joint Quick-lock for adjustment to any height on extruded aluminium profile VESA fastening 7.5 x 7.5cm Includes VESA 75 (7.5x7.5) - VESA 100 (10x10) adapter 2 Cable clips Adequate carrying capacity 15kg / 33lbs TFT monitor can be turned parallel to the table edge Separation can be adjusted to anywhere between 105 and 480mm Additionally included: Cable management set for installing cables along the profiles of the aluminium lab system furniture in the SybaPro range, consisting of: 3 Cross cable binders for front and rear grooves of aluminium profile 3 Cross cable binders for side grooves of aluminium profile 12 Cable binders 4 Aluminium cover profiles for covering and enabling wires to be run along the grooves of an aluminium profile 99 Keyboard adapter for flat screen monitor holders ST8010-4G 1 Keyboard adapter for use in combination with flat screen monitor holders Mounted between monitor and mount for flat screen monitor holder Variable 3-level height adjustment via multiple pre-drilled mounting holes Two rows of mounting holes for use with equipment meeting VESA 75 and VESA 100 standards Keyboard shelf inclined by about 30 for comfortable and ergonomic usability Keyboard shelf with 11-mm folded edging to prevent falling, including handle Variable 2-level depth attachment for keyboard shelf (252/276 mm) Extra-wide keyboard shelf (640 mm) can accommodate a mouse as well Depth of keyboard shelf 172 mm Includes two cable clips for guiding and bundling cables Maximum load 10 kg Dimensions (HxWxD) 360 x 640 x 276 mm Lucas Nülle GmbH Page 62/118

63 100 Protection cover for three-level experiment trolleys ST8010-9Y 1 Dust cover for three-level experiment trolleys For protecting equipment from dust and damp For keeping equipment out of sight (the cover must not be transparent, so is therefore opaque) Colour: matt dark grey with printed LN logo in orange) Material: nylon fabric with polyurethane coating High resistant to tearing, impregnated to be washable and waterproof EUL 5 Investigations on three phase cables EUL 5 Investigations on three phase cables Training contents: Ferranti effect, charging capacity, critical length Resistive, inductive and resistive-inductive mixed loads Compensation for a resistive-inductive load Determining zero impedance Symmetric and asymmetric shorts Dealing with star points and shorts to earth Lucas Nülle GmbH Page 63/118

64 Supplement to basic set, consisting of: Supplement to basic set, consisting of: Pos. Product name Bestell-Nr. Anz. 101 Cable transmission line model 12,5km/37,5km (23.3miles/7.8miles) CO3301-3C 1 Three-phase line simulation of a high voltage underground cable with different lengths for measuring various operational states (open-line, matched, short-circuit). Scale factor 1/1000 for current and voltage. Transmission line length: 12,5km 37,5km Transmission line length: 23.3 miles 7.8 miles Resistance per phase: 0,25Ohm 0,75 Ohm Inductance per phase: 6,25mH 18,75mH Capacity per phase: 2 x 2µF 6µF Max power consumption: 400W Voltage: 3x 110V; 50/60Hz Current: 1A Inputs/outputs: 4mm safety sockets Dimensions: 297 x 456 x 125mm (HxWxD) Weight: 5kg. 102 Conversion station 380 V/110 V CO3301-3M 1 Transformer for supplying electricity to simulated transmission line. Scale 1/1000 for voltage and current on the secondary side. Primary: 3 x 380-V windings Secondary: 3 x 110-V windings Nominal power: 400VA Vector group: YNyn0 Protection: 1 automatic circuit breaker, A (adjustable) Input/outputs: 4-mm safety sockets Dimensions: 297 x 228 x 150 mm Weight: 7.5 kg Media: Lucas Nülle GmbH Page 64/118

65 Media: Pos. Product name Bestell-Nr. Anz. 103 Interactive Lab Assistant: High-voltage transmission lines SO2800-6K 1 The experiment instructions come in the form of an Interactive Lab Assistant course. This multimedia course is a step-by-step guide through the topic of modern energy systems. The fundamentals are conveyed using easy to understand animations. The Interactive Lab Assistant in conjunction with the SCADA Viewer constitutes a comfortable experimenting environment. Special features: Interactive experiment setups Measured values and diagrams can be stored in the experiment instructions per drag and drop The SCADA Viewer can be started directly from the experiment instructions Includes questions with feedback and evaluation logic for progress monitoring Documents can be printed out for hardcopy of experiment instructions including solutions CD-ROM with Labsoft browser, course software and SCADA Viewer Training contents: Studies of three-phase lines Voltage increases on open-circuit lines Voltage drop as a function of line length Voltage drop as a function of cos phi Capacitive and inductive power losses on a line as a function of V and I Phase shift on a line Parallel and series connection of transmission lines Distribution of power and current among parallelconnected lines of equal length Distribution of power and current among parallelconnected lines of unequal length Distribution of power and current among series-connected lines of equal length Distribution of power and current among series-connected Lucas Nülle GmbH Page 65/118

66 lines of unequal length Load distribution, power flow Voltage distribution Quantitative and qualitative evaluations of operational relationships Study of lines with earth-fault compensation Earth fault on a line with an isolated star point Response to earth faults Earth-fault compensation Studies on power transmission systems with synchronous generators Power and current distribution in a line network fed by a generator Parallel operation of a generator and line via the network Control of active power feed Control of reactive power feed Investigations on three phase cables Ferranti effect, charging capacity, critical length Resistive, inductive and resistive-inductive mixed loads Compensation for a resistive-inductive load Determining zero impedance Symmetric and asymmetric shorts Dealing with star points and shorts to earth Combined networks of cables and lines Differences between cables and transmission lines Investigation of connections: - Transmission lines, transformers and cables - Cables, transformers and transmission lines Losses from individual components Parameters for sub-stations Controlling flow of power in meshed networks Variable transformers Transformer with in-phase regulation (in-phase booster) Transformer with regulation in quadrature (quadrature booster) Phase-angle-regulating transformer (phase-shifting transformer) Affect flow of power via two identical conductors parallel to one another Course duration 22 h approx. Lucas Nülle GmbH Page 66/118

67 Software: Pos. Product name Bestell-Nr. Anz. 104 Software SCADA Viewer SO4001-3H 1 The 'SCADA Viewer' is a software program used for the control and monitoring of power engineering systems. With the software it is possible to display all measured values and operating states inside the system in real time on the existing measuring instruments. Important parameters and signals can be controlled by the software. The measured values and operating states of the equipment can be selected, recorded and plotted over time, evaluated and then exported. Using the 'SCADA Viewer' projects in power engineering are not only made transparent but readable. Software functions: Display of measured values and operating states in real time Plotting of measured values over time in diagrams Processing, analyzing and exporting of diagrams The SCADA viewer contains more than 20 predefined projects Many projects designed with the SCADA designer can be individually expanded at will 105 Patch cable Cat5E 1x 1m yellow, 2x 2m yellow LM x 1m yellow 2x 2m yellow Lucas Nülle GmbH Page 67/118

68 106 USB Network Adapter 10/100 BaseTX RJ45 LM USB-Ethernet adapter provides simple network access without having to install expansion card. The adapter is thus well-suited especially for cases where there are no more slots available in the PC or the housing should not be opened. This adapter is also an alternative for notebooks: instead of a PC card with an Ethernet port the adapter offers a universal connection option for all PCs with USB interface. USB 2.0 high-speed device Downward compatible with USB 1.1 and 1.0 Host controllers Compatible with IEEE 802.3u, 10/100 Base-T and TX Supports both full and half-duplex mode on Ethernet interface Operating systems: Windows ME/200/XP/Vista,7 (32+64 Bit), Linux, Mac OS 10.x Port Ethernet Switch LM Port Ethernet Switch 5 RJ45 terminals Power supply Lucas Nülle GmbH Page 68/118

69 Power supply: Pos. Product name Bestell-Nr. Anz. 108 Adjustable 3-phase power supply, 0-450V/2A CO3301-3Z 1 Controllable 3-phase power supply unit /450V for continuous 3-phase supply Power connection: 230/400V, 50/60Hz Output voltage: 3x V, 50/60Hz variable by means of 3- phase regulating transformer (tolerance 0.5%) DC output V Output current: 2.0A 4-mm safety sockets (L1, L2, L3, N, PE, L-, L+) 1 Voltmeter, V (moving iron instrument) 1 Ammeter, 0...3A (moving iron instrument) 3 Phase control lights 1 Measuring point selector switch. L1-N, L2-N, L3-N, L1-L2, L1-L3, L2-L3 1 Measuring point selector switch. I1, I2, I3 Protection: 3 thermo-magnetic device circuit breakers, Motor protection switch adjustable from A with undervoltage trip Table-top housing with fold-away stand Dimensions: 175 x 370 x 260mm (HxWxD) Weight: 15kg 109 Multiple socket outlet, 6 fold, with illuminated switch ST8010-4J 2 Multiple socket outlet, 6 fold, with illuminated switch, 2 pole 6 earth pin sockets acoording to DIN49440, 250V~,16A power cord 1,5m Dimensions: 439 x 60 x 44mm (LxWxH) Lucas Nülle GmbH Page 69/118

70 Measuring instruments: Pos. Product name Bestell-Nr. Anz. 110 Three-phase power quality meter, display and long-term memory CO5127-1S 2 The three-phase measuring instrument permits the measurement and display of relevant power network parameters. It is able to measure single, two-phase or three-phase measurements. The display and operation is carried out by means of menu navigation with an LC display or the integrated Ethernet interface. The optional SCADA software provides for the display of all measurements and allows the implementation and analysis of intelligent networks (smart grids). The smart meter acts as a digital electricity meter where end customers are connected to the grid in order to measure electricity consumption and can be used to turn consumers on or off depending on the circumstances. Three-phase measurement of current and voltage 3x400V/5A Measurement of phase voltages, line-to-line voltages and currents Determination of the apparent, active and reactive power Determination of active, reactive and apparent work Determination of the frequency and distortion factors for current and voltage Detection of harmonic oscillations and neutral conductor current in the electricity supply Pulse measurement Peak and mean value detection Event logging Real-time clock Large-scale, contrast-rich graphic display with background illumination Display in tables, diagrams and vector diagrams 2 Digital inputs and outputs for free configuration including functions Ethernet interface Menu navigation in German/English/ French/Spanish/Italian/Portuguese/Turkish/ Chinese/Russian/Polish Demonstration measuring instrument for making measurements on the electricity supply grid Max. measurement values: Voltage P-P: 690 V Current: 5 A Fault tolerances: Voltage 0.2% Current 0.2% Apparent power 0.5% Active power 0.2% Reactive power 1% Active energy Class 0.2 Reactive energy Class 2 Operating voltage: 110V-230V, 50/60Hz Dimensions: 297 x 228 x 140mm (HxWxD) Weight: 2kg Lucas Nülle GmbH Page 70/118

71 Accessories: Pos. Product name Bestell-Nr. Anz. 111 Safety connecting plug 4mm with tap (2x), black, 1000V/32A CAT II SO5126-3R 40 Moulded insulation both sides with touch protection (safety plug + safety sockets), distance 19mm transition resistance max. 6mΩ rated data: 1000V/32A CAT II colour black 112 Safety connecting plug 4mm with tap (2x), blue, 1000V/32A CAT II SO5126-3V 2 Moulded insulation both sides with touch protection (safety plug + safety sockets), distance 19mm transition resistance max. 6mΩ rated data: 1000V/32A CAT II colour blue 113 Safety connecting plug 4mm with tap (2x), green/yellow, 1000V/32A CAT II SO5126-3W 7 Moulded insulation both sides with touch protection (safety plug + safety sockets), distance 19mm transition resistance max. 6mΩ rated data: 1000V/32A CAT II colour green/yellow Lucas Nülle GmbH Page 71/118

72 114 Set of safety measurement cables, 4mm (31 leads) SO5148-1L 1 Safety measurement cables with 4mm safety plugs, coloured, PVC insulation, highly flexible Each set includes the following: 6 x 25cm long, black 4 x 50cm long, black 2 x 100cm long, blue 2 x 100cm long, red 1 x 100cm long, green/yellow 1 x 150cm long, blue 1 x 150cm long, green/yellow 2 x 150cm long, green 4 x 150cm long, brown 4 x 150cm long, black 4 x 150cm long, grey Wire cross section 2.5 mm ² Capacity/category: 600V CAT II, 32A 115 Safety measurement cable (4mm), 50cm, black SO5126-8L 6 Safety measurement lead with stackable, contact-proof 4mm plugs Colour: black Length: 50 cm Wire cross section 2.5 mm Safety measurement cable (4mm), 25cm/10", black SO5126-8B 3 Safety measurement lead with stackable, contact-proof 4mm plugs colour: black length: 25 cm cable cross-section 2,5 mm 2 ratings deliver: 600V CAT II, 32A Lucas Nülle GmbH Page 72/118

73 117 Mobile aluminium experiment stand, 3 levels, power strip with 6 sockets, 1250x700x1995mm ST7200-3A 1 High-quality, mobile experiments stand from the SybaPro range for demonstrations and experiments. Features aluminium profile legs compatible with all add-ons and extensions for the SybaPro system. The mobile experiment stand is supplied in kit form and needs to be assembled by customers themselves. Table top: Frame: Dimensions: 30-mm table top made of highly compressed, multi-layer fine chipboard conforming to DIN EN Colour grey, RAL 7035, with 0.8-mm slightly textured laminate coating (Resopal) on both sides, conforming to DIN Resistant to many chemicals and reagents including dilute acids and alkalis Resistant to heat, e.g. molten solder or heating at specific points such as by soldering tips or cigarette ends Table top with solid impact-resistant protective edging made of 3mm thick RAL 7047 coloured plastic Coating and adhesive are PVC free Power strip with 6 outlet sockets mounted underneath the table top, lead and earthed plug 2 extruded aluminium profiles with multiple grooves 1800 x 120 x 40 mm (WxHxD) 8 equally sized grooves in extruded aluminium profiles (3 on each side and 1 each on the front and back) Grooves accommodate standard industrial mountings 4 H-shaped aluminium profiles, 1150 mm, for 3-layer organisation of DIN A4 panels Space for extension of power supply duct Base made of rectangular tubing with 4 swiveling double casters, 2 of which have brakes Table frame made of tough combination of rectangular tubing around the full perimeter Acid-resistant epoxy-resin coating, 80 µm thick (approx.), colour RAL 7047 Height of table top 760 mm 1250 x 1995 x 700 mm (WxHxD) Lucas Nülle GmbH Page 73/118

74 118 Protected power distribution for working stations ST8008-8M V CEE distribution panel with automatic circuit breakers for attachment to profiles on experiment trolleys or direct to table-top. 2 CEE sockets (400 V, 16 A, 5-pole) with safety flap 1 Socket outlet with earth (230 V) plus safety flap Circuit breaker: 1 x 3-pole line circuit breaker, type B, 16 A Power connection: 3 x 230/400 V, 50/60 Hz via CEE plug, 4-m power lead Dimensions: 530 x 130 x 110 mm (HxWxD) Weight: 3 kg 119 Wall or aluminium-profile mounting cable storage for 48 cables ST8003-8E 1 Accommodates about 48 safety measuring leads (4mm), suitable for mounting on walls or aluminium profiles Width 200 mm, 12 guide grooves for leads Adjustable height for mounting on aluminium profiles Can be mounted on the left or right Can be mounted on walls Includes 2 screws and tenon blocks Acid-resistant epoxy-resin powder coating, thickness 80 µm approx., colour RAL PC holder for SybaPro experiment trolleys, height/width adjustable ST7200-5A 1 Shelf for desktop PC made of 1.5mm sheet steel punched with holes, suitable for all furniture in the SybaPro aluminium profile range Adjustable assembly height Adjustable width ( mm) Can be mounted to left or right Includes all equipment necessary for assembly (4 bolts and 4 tenon blocks) Acid-resistant epoxy-resin powder coating, 80µm thick approx., colour RAL7047 Lucas Nülle GmbH Page 74/118

75 121 Monitor holder for flat screen monitor of weight up to 15kg / 33lbs ST8010-4T 1 Pivoting monitor holder for attachment to aluminium profiles of furniture in the SybaPro range. Allows a monitor to be placed in the optimum position so that work and experiments are less tiring. Pivoting arm with two-part joint Quick-lock for adjustment to any height on extruded aluminium profile VESA fastening 7.5 x 7.5cm Includes VESA 75 (7.5x7.5) - VESA 100 (10x10) adapter 2 Cable clips Adequate carrying capacity 15kg / 33lbs TFT monitor can be turned parallel to the table edge Separation can be adjusted to anywhere between 105 and 480mm Additionally included: Cable management set for installing cables along the profiles of the aluminium lab system furniture in the SybaPro range, consisting of: 3 Cross cable binders for front and rear grooves of aluminium profile 3 Cross cable binders for side grooves of aluminium profile 12 Cable binders 4 Aluminium cover profiles for covering and enabling wires to be run along the grooves of an aluminium profile 122 Keyboard adapter for flat screen monitor holders ST8010-4G 1 Keyboard adapter for use in combination with flat screen monitor holders Mounted between monitor and mount for flat screen monitor holder Variable 3-level height adjustment via multiple pre-drilled mounting holes Two rows of mounting holes for use with equipment meeting VESA 75 and VESA 100 standards Keyboard shelf inclined by about 30 for comfortable and ergonomic usability Keyboard shelf with 11-mm folded edging to prevent falling, including handle Variable 2-level depth attachment for keyboard shelf (252/276 mm) Extra-wide keyboard shelf (640 mm) can accommodate a mouse as well Depth of keyboard shelf 172 mm Includes two cable clips for guiding and bundling cables Maximum load 10 kg Dimensions (HxWxD) 360 x 640 x 276 mm Lucas Nülle GmbH Page 75/118

76 123 Protection cover for three-level experiment trolleys ST8010-9Y 1 Dust cover for three-level experiment trolleys For protecting equipment from dust and damp For keeping equipment out of sight (the cover must not be transparent, so is therefore opaque) Colour: matt dark grey with printed LN logo in orange) Material: nylon fabric with polyurethane coating High resistant to tearing, impregnated to be washable and waterproof EUL 6 Combined networks of cables and lines EUL 6 Combined networks of cables and lines Training contents: Differences between cables and transmission lines Investigation of connections: - Transmission lines, transformers and cables - Cables, transformers and transmission lines Losses from individual components Comparisons between theory and practice Parameters for sub-stations Lucas Nülle GmbH Page 76/118

77 Supplement to basic set, consisting of: Supplement to basic set, consisting of: Pos. Product name Bestell-Nr. Anz. 124 Cable transmission line model 12,5km/37,5km (23.3miles/7.8miles) CO3301-3C 1 Three-phase line simulation of a high voltage underground cable with different lengths for measuring various operational states (open-line, matched, short-circuit). Scale factor 1/1000 for current and voltage. Transmission line length: 12,5km 37,5km Transmission line length: 23.3 miles 7.8 miles Resistance per phase: 0,25Ohm 0,75 Ohm Inductance per phase: 6,25mH 18,75mH Capacity per phase: 2 x 2µF 6µF Max power consumption: 400W Voltage: 3x 110V; 50/60Hz Current: 1A Inputs/outputs: 4mm safety sockets Dimensions: 297 x 456 x 125mm (HxWxD) Weight: 5kg. 125 Conversion station 380 V/110 V CO3301-3M 1 Transformer for supplying electricity to simulated transmission line. Scale 1/1000 for voltage and current on the secondary side. Primary: 3 x 380-V windings Secondary: 3 x 110-V windings Nominal power: 400VA Vector group: YNyn0 Protection: 1 automatic circuit breaker, A (adjustable) Input/outputs: 4-mm safety sockets Dimensions: 297 x 228 x 150 mm Weight: 7.5 kg Lucas Nülle GmbH Page 77/118

78 126 Three-phase power quality meter, display and long-term memory CO5127-1S 2 The three-phase measuring instrument permits the measurement and display of relevant power network parameters. It is able to measure single, two-phase or three-phase measurements. The display and operation is carried out by means of menu navigation with an LC display or the integrated Ethernet interface. The optional SCADA software provides for the display of all measurements and allows the implementation and analysis of intelligent networks (smart grids). The smart meter acts as a digital electricity meter where end customers are connected to the grid in order to measure electricity consumption and can be used to turn consumers on or off depending on the circumstances. Three-phase measurement of current and voltage 3x400V/5A Measurement of phase voltages, line-to-line voltages and currents Determination of the apparent, active and reactive power Determination of active, reactive and apparent work Determination of the frequency and distortion factors for current and voltage Detection of harmonic oscillations and neutral conductor current in the electricity supply Pulse measurement Peak and mean value detection Event logging Real-time clock Large-scale, contrast-rich graphic display with background illumination Display in tables, diagrams and vector diagrams 2 Digital inputs and outputs for free configuration including functions Ethernet interface Menu navigation in German/English/ French/Spanish/Italian/Portuguese/Turkish/ Chinese/Russian/Polish Demonstration measuring instrument for making measurements on the electricity supply grid Max. measurement values: Voltage P-P: 690 V Current: 5 A Fault tolerances: Voltage 0.2% Current 0.2% Apparent power 0.5% Active power 0.2% Reactive power 1% Active energy Class 0.2 Reactive energy Class 2 Operating voltage: 110V-230V, 50/60Hz Dimensions: 297 x 228 x 140mm (HxWxD) Weight: 2kg Media: Lucas Nülle GmbH Page 78/118

79 Pos. Product name Bestell-Nr. Anz. 127 Interactive Lab Assistant: High-voltage transmission lines SO2800-6K 1 The experiment instructions come in the form of an Interactive Lab Assistant course. This multimedia course is a step-by-step guide through the topic of modern energy systems. The fundamentals are conveyed using easy to understand animations. The Interactive Lab Assistant in conjunction with the SCADA Viewer constitutes a comfortable experimenting environment. Special features: Interactive experiment setups Measured values and diagrams can be stored in the experiment instructions per drag and drop The SCADA Viewer can be started directly from the experiment instructions Includes questions with feedback and evaluation logic for progress monitoring Documents can be printed out for hardcopy of experiment instructions including solutions CD-ROM with Labsoft browser, course software and SCADA Viewer Training contents: Studies of three-phase lines Voltage increases on open-circuit lines Voltage drop as a function of line length Voltage drop as a function of cos phi Capacitive and inductive power losses on a line as a function of V and I Phase shift on a line Parallel and series connection of transmission lines Distribution of power and current among parallelconnected lines of equal length Distribution of power and current among parallelconnected lines of unequal length Distribution of power and current among series-connected lines of equal length Distribution of power and current among series-connected lines of unequal length Load distribution, power flow Voltage distribution Lucas Nülle GmbH Page 79/118

80 Quantitative and qualitative evaluations of operational relationships Study of lines with earth-fault compensation Earth fault on a line with an isolated star point Response to earth faults Earth-fault compensation Studies on power transmission systems with synchronous generators Power and current distribution in a line network fed by a generator Parallel operation of a generator and line via the network Control of active power feed Control of reactive power feed Investigations on three phase cables Ferranti effect, charging capacity, critical length Resistive, inductive and resistive-inductive mixed loads Compensation for a resistive-inductive load Determining zero impedance Symmetric and asymmetric shorts Dealing with star points and shorts to earth Combined networks of cables and lines Differences between cables and transmission lines Investigation of connections: - Transmission lines, transformers and cables - Cables, transformers and transmission lines Losses from individual components Parameters for sub-stations Controlling flow of power in meshed networks Variable transformers Transformer with in-phase regulation (in-phase booster) Transformer with regulation in quadrature (quadrature booster) Phase-angle-regulating transformer (phase-shifting transformer) Affect flow of power via two identical conductors parallel to one another Course duration 22 h approx. Lucas Nülle GmbH Page 80/118

81 Software: Pos. Product name Bestell-Nr. Anz. 128 Software SCADA Viewer SO4001-3H 1 The 'SCADA Viewer' is a software program used for the control and monitoring of power engineering systems. With the software it is possible to display all measured values and operating states inside the system in real time on the existing measuring instruments. Important parameters and signals can be controlled by the software. The measured values and operating states of the equipment can be selected, recorded and plotted over time, evaluated and then exported. Using the 'SCADA Viewer' projects in power engineering are not only made transparent but readable. Software functions: Display of measured values and operating states in real time Plotting of measured values over time in diagrams Processing, analyzing and exporting of diagrams The SCADA viewer contains more than 20 predefined projects Many projects designed with the SCADA designer can be individually expanded at will 129 Patch cable Cat5E 1x 1m yellow, 2x 2m yellow LM x 1m yellow 2x 2m yellow Lucas Nülle GmbH Page 81/118

82 130 USB Network Adapter 10/100 BaseTX RJ45 LM USB-Ethernet adapter provides simple network access without having to install expansion card. The adapter is thus well-suited especially for cases where there are no more slots available in the PC or the housing should not be opened. This adapter is also an alternative for notebooks: instead of a PC card with an Ethernet port the adapter offers a universal connection option for all PCs with USB interface. USB 2.0 high-speed device Downward compatible with USB 1.1 and 1.0 Host controllers Compatible with IEEE 802.3u, 10/100 Base-T and TX Supports both full and half-duplex mode on Ethernet interface Operating systems: Windows ME/200/XP/Vista,7 (32+64 Bit), Linux, Mac OS 10.x Port Ethernet Switch LM Port Ethernet Switch 5 RJ45 terminals Power supply Lucas Nülle GmbH Page 82/118

83 Power supply: Pos. Product name Bestell-Nr. Anz. 132 Adjustable 3-phase power supply, 0-450V/2A CO3301-3Z 1 Controllable 3-phase power supply unit /450V for continuous 3-phase supply Power connection: 230/400V, 50/60Hz Output voltage: 3x V, 50/60Hz variable by means of 3- phase regulating transformer (tolerance 0.5%) DC output V Output current: 2.0A 4-mm safety sockets (L1, L2, L3, N, PE, L-, L+) 1 Voltmeter, V (moving iron instrument) 1 Ammeter, 0...3A (moving iron instrument) 3 Phase control lights 1 Measuring point selector switch. L1-N, L2-N, L3-N, L1-L2, L1-L3, L2-L3 1 Measuring point selector switch. I1, I2, I3 Protection: 3 thermo-magnetic device circuit breakers, Motor protection switch adjustable from A with undervoltage trip Table-top housing with fold-away stand Dimensions: 175 x 370 x 260mm (HxWxD) Weight: 15kg 133 Multiple socket outlet, 6 fold, with illuminated switch ST8010-4J 2 Multiple socket outlet, 6 fold, with illuminated switch, 2 pole 6 earth pin sockets acoording to DIN49440, 250V~,16A power cord 1,5m Dimensions: 439 x 60 x 44mm (LxWxH) Lucas Nülle GmbH Page 83/118

84 Measuring instruments: Pos. Product name Bestell-Nr. Anz. 134 Three-phase power quality meter, display and long-term memory CO5127-1S 2 The three-phase measuring instrument permits the measurement and display of relevant power network parameters. It is able to measure single, two-phase or three-phase measurements. The display and operation is carried out by means of menu navigation with an LC display or the integrated Ethernet interface. The optional SCADA software provides for the display of all measurements and allows the implementation and analysis of intelligent networks (smart grids). The smart meter acts as a digital electricity meter where end customers are connected to the grid in order to measure electricity consumption and can be used to turn consumers on or off depending on the circumstances. Three-phase measurement of current and voltage 3x400V/5A Measurement of phase voltages, line-to-line voltages and currents Determination of the apparent, active and reactive power Determination of active, reactive and apparent work Determination of the frequency and distortion factors for current and voltage Detection of harmonic oscillations and neutral conductor current in the electricity supply Pulse measurement Peak and mean value detection Event logging Real-time clock Large-scale, contrast-rich graphic display with background illumination Display in tables, diagrams and vector diagrams 2 Digital inputs and outputs for free configuration including functions Ethernet interface Menu navigation in German/English/ French/Spanish/Italian/Portuguese/Turkish/ Chinese/Russian/Polish Demonstration measuring instrument for making measurements on the electricity supply grid Max. measurement values: Voltage P-P: 690 V Current: 5 A Fault tolerances: Voltage 0.2% Current 0.2% Apparent power 0.5% Active power 0.2% Reactive power 1% Active energy Class 0.2 Reactive energy Class 2 Operating voltage: 110V-230V, 50/60Hz Dimensions: 297 x 228 x 140mm (HxWxD) Weight: 2kg Lucas Nülle GmbH Page 84/118

85 Accessories: Pos. Product name Bestell-Nr. Anz. 135 Safety connecting plug 4mm with tap (2x), black, 1000V/32A CAT II SO5126-3R 40 Moulded insulation both sides with touch protection (safety plug + safety sockets), distance 19mm transition resistance max. 6mΩ rated data: 1000V/32A CAT II colour black 136 Safety connecting plug 4mm with tap (2x), blue, 1000V/32A CAT II SO5126-3V 2 Moulded insulation both sides with touch protection (safety plug + safety sockets), distance 19mm transition resistance max. 6mΩ rated data: 1000V/32A CAT II colour blue 137 Safety connecting plug 4mm with tap (2x), green/yellow, 1000V/32A CAT II SO5126-3W 7 Moulded insulation both sides with touch protection (safety plug + safety sockets), distance 19mm transition resistance max. 6mΩ rated data: 1000V/32A CAT II colour green/yellow Lucas Nülle GmbH Page 85/118

86 138 Set of safety measurement cables, 4mm (31 leads) SO5148-1L 1 Safety measurement cables with 4mm safety plugs, coloured, PVC insulation, highly flexible Each set includes the following: 6 x 25cm long, black 4 x 50cm long, black 2 x 100cm long, blue 2 x 100cm long, red 1 x 100cm long, green/yellow 1 x 150cm long, blue 1 x 150cm long, green/yellow 2 x 150cm long, green 4 x 150cm long, brown 4 x 150cm long, black 4 x 150cm long, grey Wire cross section 2.5 mm ² Capacity/category: 600V CAT II, 32A 139 Safety measurement cable (4mm), 50cm, black SO5126-8L 6 Safety measurement lead with stackable, contact-proof 4mm plugs Colour: black Length: 50 cm Wire cross section 2.5 mm Safety measurement cable (4mm), 25cm/10", black SO5126-8B 3 Safety measurement lead with stackable, contact-proof 4mm plugs colour: black length: 25 cm cable cross-section 2,5 mm 2 ratings deliver: 600V CAT II, 32A Lucas Nülle GmbH Page 86/118

87 141 Mobile aluminium experiment stand, 3 levels, power strip with 6 sockets, 1250x700x1995mm ST7200-3A 1 High-quality, mobile experiments stand from the SybaPro range for demonstrations and experiments. Features aluminium profile legs compatible with all add-ons and extensions for the SybaPro system. The mobile experiment stand is supplied in kit form and needs to be assembled by customers themselves. Table top: Frame: Dimensions: 30-mm table top made of highly compressed, multi-layer fine chipboard conforming to DIN EN Colour grey, RAL 7035, with 0.8-mm slightly textured laminate coating (Resopal) on both sides, conforming to DIN Resistant to many chemicals and reagents including dilute acids and alkalis Resistant to heat, e.g. molten solder or heating at specific points such as by soldering tips or cigarette ends Table top with solid impact-resistant protective edging made of 3mm thick RAL 7047 coloured plastic Coating and adhesive are PVC free Power strip with 6 outlet sockets mounted underneath the table top, lead and earthed plug 2 extruded aluminium profiles with multiple grooves 1800 x 120 x 40 mm (WxHxD) 8 equally sized grooves in extruded aluminium profiles (3 on each side and 1 each on the front and back) Grooves accommodate standard industrial mountings 4 H-shaped aluminium profiles, 1150 mm, for 3-layer organisation of DIN A4 panels Space for extension of power supply duct Base made of rectangular tubing with 4 swiveling double casters, 2 of which have brakes Table frame made of tough combination of rectangular tubing around the full perimeter Acid-resistant epoxy-resin coating, 80 µm thick (approx.), colour RAL 7047 Height of table top 760 mm 1250 x 1995 x 700 mm (WxHxD) Lucas Nülle GmbH Page 87/118

88 142 Protected power distribution for working stations ST8008-8M V CEE distribution panel with automatic circuit breakers for attachment to profiles on experiment trolleys or direct to table-top. 2 CEE sockets (400 V, 16 A, 5-pole) with safety flap 1 Socket outlet with earth (230 V) plus safety flap Circuit breaker: 1 x 3-pole line circuit breaker, type B, 16 A Power connection: 3 x 230/400 V, 50/60 Hz via CEE plug, 4-m power lead Dimensions: 530 x 130 x 110 mm (HxWxD) Weight: 3 kg 143 Wall or aluminium-profile mounting cable storage for 48 cables ST8003-8E 1 Accommodates about 48 safety measuring leads (4mm), suitable for mounting on walls or aluminium profiles Width 200 mm, 12 guide grooves for leads Adjustable height for mounting on aluminium profiles Can be mounted on the left or right Can be mounted on walls Includes 2 screws and tenon blocks Acid-resistant epoxy-resin powder coating, thickness 80 µm approx., colour RAL PC holder for SybaPro experiment trolleys, height/width adjustable ST7200-5A 1 Shelf for desktop PC made of 1.5mm sheet steel punched with holes, suitable for all furniture in the SybaPro aluminium profile range Adjustable assembly height Adjustable width ( mm) Can be mounted to left or right Includes all equipment necessary for assembly (4 bolts and 4 tenon blocks) Acid-resistant epoxy-resin powder coating, 80µm thick approx., colour RAL7047 Lucas Nülle GmbH Page 88/118

89 145 Monitor holder for flat screen monitor of weight up to 15kg / 33lbs ST8010-4T 1 Pivoting monitor holder for attachment to aluminium profiles of furniture in the SybaPro range. Allows a monitor to be placed in the optimum position so that work and experiments are less tiring. Pivoting arm with two-part joint Quick-lock for adjustment to any height on extruded aluminium profile VESA fastening 7.5 x 7.5cm Includes VESA 75 (7.5x7.5) - VESA 100 (10x10) adapter 2 Cable clips Adequate carrying capacity 15kg / 33lbs TFT monitor can be turned parallel to the table edge Separation can be adjusted to anywhere between 105 and 480mm Additionally included: Cable management set for installing cables along the profiles of the aluminium lab system furniture in the SybaPro range, consisting of: 3 Cross cable binders for front and rear grooves of aluminium profile 3 Cross cable binders for side grooves of aluminium profile 12 Cable binders 4 Aluminium cover profiles for covering and enabling wires to be run along the grooves of an aluminium profile 146 Keyboard adapter for flat screen monitor holders ST8010-4G 1 Keyboard adapter for use in combination with flat screen monitor holders Mounted between monitor and mount for flat screen monitor holder Variable 3-level height adjustment via multiple pre-drilled mounting holes Two rows of mounting holes for use with equipment meeting VESA 75 and VESA 100 standards Keyboard shelf inclined by about 30 for comfortable and ergonomic usability Keyboard shelf with 11-mm folded edging to prevent falling, including handle Variable 2-level depth attachment for keyboard shelf (252/276 mm) Extra-wide keyboard shelf (640 mm) can accommodate a mouse as well Depth of keyboard shelf 172 mm Includes two cable clips for guiding and bundling cables Maximum load 10 kg Dimensions (HxWxD) 360 x 640 x 276 mm Lucas Nülle GmbH Page 89/118

90 147 Protection cover for three-level experiment trolleys ST8010-9Y 1 Dust cover for three-level experiment trolleys For protecting equipment from dust and damp For keeping equipment out of sight (the cover must not be transparent, so is therefore opaque) Colour: matt dark grey with printed LN logo in orange) Material: nylon fabric with polyurethane coating High resistant to tearing, impregnated to be washable and waterproof EUL 7 Controlling flow of power in meshed networks EUL 7 Controlling flow of power in meshed networks Training contents: Variable transformers Transformer with in-phase regulation (in-phase booster) Transformer with regulation in quadrature (quadrature booster) Phase-angle-regulating transformer (phase-shifting transformer) Affect flow of power via two identical conductors parallel to one another Comparison between theory and practice Lucas Nülle GmbH Page 90/118

91 Supplement to basic set, consisting of: Supplement to basic set, consisting of: Pos. Product name Bestell-Nr. Anz. 148 Isolating transformer, Three-phase, 1kW CO3301-3N 1 Transformer for feeding the transmission line model. Scale factor 1:1000 for secondary current and voltage. Input voltages: 3 x 400V Output voltage 1: 3 x 400V, 2 A Output voltage 2: 3 x 30V, 1.25A Power rating: 1000 VA, for a short time: 2000VA Vector group: Dyn5 Protection: 1 automatic circuit breaker A, adjustable Inputs/Outputs: 4mm safety sockets Dimensions: 297 x 456 x 150 mm Weight: 11kg 149 Transmission line Model 150km/300km (93.2miles/186.4miles) CO3301-3A 1 Three-phase line simulation of a high voltage overhead power line with different lengths for measuring various operational states (open-line, matched, short-circuit). Scale factor 1/1000 for current and voltage. Automatic modification of wire length as soon as the corresponding overlay is in place. Transmission line length: 150km or 300km Transmission line length: 93.2 miles or miles Resistance per phase: 3,6Ohm 7,2 Ohm Inductance per phase: 115mH 230mH Capacity per phase: Line-to-line: 2 x 150nF 300nF Line-to-ground: 2 x 0,55µF 1,1µF Max power consumption: 1kW Voltage: 3x 400V; 50/60Hz Current: 2A Inputs/outputs: 4mm safety sockets Dimensions: 297 x 456 x 125mm (HxWxD) Weight: 6kg. Lucas Nülle GmbH Page 91/118

92 150 Three-phase power quality meter, display and long-term memory CO5127-1S 1 The three-phase measuring instrument permits the measurement and display of relevant power network parameters. It is able to measure single, two-phase or three-phase measurements. The display and operation is carried out by means of menu navigation with an LC display or the integrated Ethernet interface. The optional SCADA software provides for the display of all measurements and allows the implementation and analysis of intelligent networks (smart grids). The smart meter acts as a digital electricity meter where end customers are connected to the grid in order to measure electricity consumption and can be used to turn consumers on or off depending on the circumstances. Three-phase measurement of current and voltage 3x400V/5A Measurement of phase voltages, line-to-line voltages and currents Determination of the apparent, active and reactive power Determination of active, reactive and apparent work Determination of the frequency and distortion factors for current and voltage Detection of harmonic oscillations and neutral conductor current in the electricity supply Pulse measurement Peak and mean value detection Event logging Real-time clock Large-scale, contrast-rich graphic display with background illumination Display in tables, diagrams and vector diagrams 2 Digital inputs and outputs for free configuration including functions Ethernet interface Menu navigation in German/English/ French/Spanish/Italian/Portuguese/Turkish/ Chinese/Russian/Polish Demonstration measuring instrument for making measurements on the electricity supply grid Max. measurement values: Voltage P-P: 690 V Current: 5 A Fault tolerances: Voltage 0.2% Current 0.2% Apparent power 0.5% Active power 0.2% Reactive power 1% Active energy Class 0.2 Reactive energy Class 2 Operating voltage: 110V-230V, 50/60Hz Dimensions: 297 x 228 x 140mm (HxWxD) Weight: 2kg Media: Lucas Nülle GmbH Page 92/118

93 Pos. Product name Bestell-Nr. Anz. 151 Interactive Lab Assistant: High-voltage transmission lines SO2800-6K 1 The experiment instructions come in the form of an Interactive Lab Assistant course. This multimedia course is a step-by-step guide through the topic of modern energy systems. The fundamentals are conveyed using easy to understand animations. The Interactive Lab Assistant in conjunction with the SCADA Viewer constitutes a comfortable experimenting environment. Special features: Interactive experiment setups Measured values and diagrams can be stored in the experiment instructions per drag and drop The SCADA Viewer can be started directly from the experiment instructions Includes questions with feedback and evaluation logic for progress monitoring Documents can be printed out for hardcopy of experiment instructions including solutions CD-ROM with Labsoft browser, course software and SCADA Viewer Training contents: Studies of three-phase lines Voltage increases on open-circuit lines Voltage drop as a function of line length Voltage drop as a function of cos phi Capacitive and inductive power losses on a line as a function of V and I Phase shift on a line Parallel and series connection of transmission lines Distribution of power and current among parallelconnected lines of equal length Distribution of power and current among parallelconnected lines of unequal length Distribution of power and current among series-connected lines of equal length Distribution of power and current among series-connected lines of unequal length Load distribution, power flow Voltage distribution Lucas Nülle GmbH Page 93/118

94 Quantitative and qualitative evaluations of operational relationships Study of lines with earth-fault compensation Earth fault on a line with an isolated star point Response to earth faults Earth-fault compensation Studies on power transmission systems with synchronous generators Power and current distribution in a line network fed by a generator Parallel operation of a generator and line via the network Control of active power feed Control of reactive power feed Investigations on three phase cables Ferranti effect, charging capacity, critical length Resistive, inductive and resistive-inductive mixed loads Compensation for a resistive-inductive load Determining zero impedance Symmetric and asymmetric shorts Dealing with star points and shorts to earth Combined networks of cables and lines Differences between cables and transmission lines Investigation of connections: - Transmission lines, transformers and cables - Cables, transformers and transmission lines Losses from individual components Parameters for sub-stations Controlling flow of power in meshed networks Variable transformers Transformer with in-phase regulation (in-phase booster) Transformer with regulation in quadrature (quadrature booster) Phase-angle-regulating transformer (phase-shifting transformer) Affect flow of power via two identical conductors parallel to one another Course duration 22 h approx. Lucas Nülle GmbH Page 94/118

95 Software: Pos. Product name Bestell-Nr. Anz. 152 Software SCADA Viewer SO4001-3H 1 The 'SCADA Viewer' is a software program used for the control and monitoring of power engineering systems. With the software it is possible to display all measured values and operating states inside the system in real time on the existing measuring instruments. Important parameters and signals can be controlled by the software. The measured values and operating states of the equipment can be selected, recorded and plotted over time, evaluated and then exported. Using the 'SCADA Viewer' projects in power engineering are not only made transparent but readable. Software functions: Display of measured values and operating states in real time Plotting of measured values over time in diagrams Processing, analyzing and exporting of diagrams The SCADA viewer contains more than 20 predefined projects Many projects designed with the SCADA designer can be individually expanded at will 153 Patch cable Cat5E 1x 1m yellow, 2x 2m yellow LM x 1m yellow 2x 2m yellow Lucas Nülle GmbH Page 95/118

96 154 USB Network Adapter 10/100 BaseTX RJ45 LM USB-Ethernet adapter provides simple network access without having to install expansion card. The adapter is thus well-suited especially for cases where there are no more slots available in the PC or the housing should not be opened. This adapter is also an alternative for notebooks: instead of a PC card with an Ethernet port the adapter offers a universal connection option for all PCs with USB interface. USB 2.0 high-speed device Downward compatible with USB 1.1 and 1.0 Host controllers Compatible with IEEE 802.3u, 10/100 Base-T and TX Supports both full and half-duplex mode on Ethernet interface Operating systems: Windows ME/200/XP/Vista,7 (32+64 Bit), Linux, Mac OS 10.x Port Ethernet Switch LM Port Ethernet Switch 5 RJ45 terminals Power supply Lucas Nülle GmbH Page 96/118

97 Power supply: Pos. Product name Bestell-Nr. Anz. 156 Adjustable 3-phase power supply, 0-450V/2A CO3301-3Z 1 Controllable 3-phase power supply unit /450V for continuous 3-phase supply Power connection: 230/400V, 50/60Hz Output voltage: 3x V, 50/60Hz variable by means of 3- phase regulating transformer (tolerance 0.5%) DC output V Output current: 2.0A 4-mm safety sockets (L1, L2, L3, N, PE, L-, L+) 1 Voltmeter, V (moving iron instrument) 1 Ammeter, 0...3A (moving iron instrument) 3 Phase control lights 1 Measuring point selector switch. L1-N, L2-N, L3-N, L1-L2, L1-L3, L2-L3 1 Measuring point selector switch. I1, I2, I3 Protection: 3 thermo-magnetic device circuit breakers, Motor protection switch adjustable from A with undervoltage trip Table-top housing with fold-away stand Dimensions: 175 x 370 x 260mm (HxWxD) Weight: 15kg 157 Multiple socket outlet, 6 fold, with illuminated switch ST8010-4J 2 Multiple socket outlet, 6 fold, with illuminated switch, 2 pole 6 earth pin sockets acoording to DIN49440, 250V~,16A power cord 1,5m Dimensions: 439 x 60 x 44mm (LxWxH) Lucas Nülle GmbH Page 97/118

98 Measuring instruments: Pos. Product name Bestell-Nr. Anz. 158 Three-phase power quality meter, display and long-term memory CO5127-1S 2 The three-phase measuring instrument permits the measurement and display of relevant power network parameters. It is able to measure single, two-phase or three-phase measurements. The display and operation is carried out by means of menu navigation with an LC display or the integrated Ethernet interface. The optional SCADA software provides for the display of all measurements and allows the implementation and analysis of intelligent networks (smart grids). The smart meter acts as a digital electricity meter where end customers are connected to the grid in order to measure electricity consumption and can be used to turn consumers on or off depending on the circumstances. Three-phase measurement of current and voltage 3x400V/5A Measurement of phase voltages, line-to-line voltages and currents Determination of the apparent, active and reactive power Determination of active, reactive and apparent work Determination of the frequency and distortion factors for current and voltage Detection of harmonic oscillations and neutral conductor current in the electricity supply Pulse measurement Peak and mean value detection Event logging Real-time clock Large-scale, contrast-rich graphic display with background illumination Display in tables, diagrams and vector diagrams 2 Digital inputs and outputs for free configuration including functions Ethernet interface Menu navigation in German/English/ French/Spanish/Italian/Portuguese/Turkish/ Chinese/Russian/Polish Demonstration measuring instrument for making measurements on the electricity supply grid Max. measurement values: Voltage P-P: 690 V Current: 5 A Fault tolerances: Voltage 0.2% Current 0.2% Apparent power 0.5% Active power 0.2% Reactive power 1% Active energy Class 0.2 Reactive energy Class 2 Operating voltage: 110V-230V, 50/60Hz Dimensions: 297 x 228 x 140mm (HxWxD) Weight: 2kg Lucas Nülle GmbH Page 98/118

99 Accessories: Pos. Product name Bestell-Nr. Anz. 159 Safety connecting plug 4mm with tap (2x), black, 1000V/32A CAT II SO5126-3R 40 Moulded insulation both sides with touch protection (safety plug + safety sockets), distance 19mm transition resistance max. 6mΩ rated data: 1000V/32A CAT II colour black 160 Safety connecting plug 4mm with tap (2x), blue, 1000V/32A CAT II SO5126-3V 2 Moulded insulation both sides with touch protection (safety plug + safety sockets), distance 19mm transition resistance max. 6mΩ rated data: 1000V/32A CAT II colour blue 161 Safety connecting plug 4mm with tap (2x), green/yellow, 1000V/32A CAT II SO5126-3W 7 Moulded insulation both sides with touch protection (safety plug + safety sockets), distance 19mm transition resistance max. 6mΩ rated data: 1000V/32A CAT II colour green/yellow Lucas Nülle GmbH Page 99/118

100 162 Set of safety measurement cables, 4mm (31 leads) SO5148-1L 1 Safety measurement cables with 4mm safety plugs, coloured, PVC insulation, highly flexible Each set includes the following: 6 x 25cm long, black 4 x 50cm long, black 2 x 100cm long, blue 2 x 100cm long, red 1 x 100cm long, green/yellow 1 x 150cm long, blue 1 x 150cm long, green/yellow 2 x 150cm long, green 4 x 150cm long, brown 4 x 150cm long, black 4 x 150cm long, grey Wire cross section 2.5 mm ² Capacity/category: 600V CAT II, 32A 163 Safety measurement cable (4mm), 50cm, black SO5126-8L 6 Safety measurement lead with stackable, contact-proof 4mm plugs Colour: black Length: 50 cm Wire cross section 2.5 mm Safety measurement cable (4mm), 25cm/10", black SO5126-8B 3 Safety measurement lead with stackable, contact-proof 4mm plugs colour: black length: 25 cm cable cross-section 2,5 mm 2 ratings deliver: 600V CAT II, 32A Lucas Nülle GmbH Page 100/118

101 165 Mobile aluminium experiment stand, 3 levels, power strip with 6 sockets, 1250x700x1995mm ST7200-3A 1 High-quality, mobile experiments stand from the SybaPro range for demonstrations and experiments. Features aluminium profile legs compatible with all add-ons and extensions for the SybaPro system. The mobile experiment stand is supplied in kit form and needs to be assembled by customers themselves. Table top: Frame: Dimensions: 30-mm table top made of highly compressed, multi-layer fine chipboard conforming to DIN EN Colour grey, RAL 7035, with 0.8-mm slightly textured laminate coating (Resopal) on both sides, conforming to DIN Resistant to many chemicals and reagents including dilute acids and alkalis Resistant to heat, e.g. molten solder or heating at specific points such as by soldering tips or cigarette ends Table top with solid impact-resistant protective edging made of 3mm thick RAL 7047 coloured plastic Coating and adhesive are PVC free Power strip with 6 outlet sockets mounted underneath the table top, lead and earthed plug 2 extruded aluminium profiles with multiple grooves 1800 x 120 x 40 mm (WxHxD) 8 equally sized grooves in extruded aluminium profiles (3 on each side and 1 each on the front and back) Grooves accommodate standard industrial mountings 4 H-shaped aluminium profiles, 1150 mm, for 3-layer organisation of DIN A4 panels Space for extension of power supply duct Base made of rectangular tubing with 4 swiveling double casters, 2 of which have brakes Table frame made of tough combination of rectangular tubing around the full perimeter Acid-resistant epoxy-resin coating, 80 µm thick (approx.), colour RAL 7047 Height of table top 760 mm 1250 x 1995 x 700 mm (WxHxD) Lucas Nülle GmbH Page 101/118

102 166 Protected power distribution for working stations ST8008-8M V CEE distribution panel with automatic circuit breakers for attachment to profiles on experiment trolleys or direct to table-top. 2 CEE sockets (400 V, 16 A, 5-pole) with safety flap 1 Socket outlet with earth (230 V) plus safety flap Circuit breaker: 1 x 3-pole line circuit breaker, type B, 16 A Power connection: 3 x 230/400 V, 50/60 Hz via CEE plug, 4-m power lead Dimensions: 530 x 130 x 110 mm (HxWxD) Weight: 3 kg 167 Wall or aluminium-profile mounting cable storage for 48 cables ST8003-8E 1 Accommodates about 48 safety measuring leads (4mm), suitable for mounting on walls or aluminium profiles Width 200 mm, 12 guide grooves for leads Adjustable height for mounting on aluminium profiles Can be mounted on the left or right Can be mounted on walls Includes 2 screws and tenon blocks Acid-resistant epoxy-resin powder coating, thickness 80 µm approx., colour RAL PC holder for SybaPro experiment trolleys, height/width adjustable ST7200-5A 1 Shelf for desktop PC made of 1.5mm sheet steel punched with holes, suitable for all furniture in the SybaPro aluminium profile range Adjustable assembly height Adjustable width ( mm) Can be mounted to left or right Includes all equipment necessary for assembly (4 bolts and 4 tenon blocks) Acid-resistant epoxy-resin powder coating, 80µm thick approx., colour RAL7047 Lucas Nülle GmbH Page 102/118

103 169 Monitor holder for flat screen monitor of weight up to 15kg / 33lbs ST8010-4T 1 Pivoting monitor holder for attachment to aluminium profiles of furniture in the SybaPro range. Allows a monitor to be placed in the optimum position so that work and experiments are less tiring. Pivoting arm with two-part joint Quick-lock for adjustment to any height on extruded aluminium profile VESA fastening 7.5 x 7.5cm Includes VESA 75 (7.5x7.5) - VESA 100 (10x10) adapter 2 Cable clips Adequate carrying capacity 15kg / 33lbs TFT monitor can be turned parallel to the table edge Separation can be adjusted to anywhere between 105 and 480mm Additionally included: Cable management set for installing cables along the profiles of the aluminium lab system furniture in the SybaPro range, consisting of: 3 Cross cable binders for front and rear grooves of aluminium profile 3 Cross cable binders for side grooves of aluminium profile 12 Cable binders 4 Aluminium cover profiles for covering and enabling wires to be run along the grooves of an aluminium profile 170 Keyboard adapter for flat screen monitor holders ST8010-4G 1 Keyboard adapter for use in combination with flat screen monitor holders Mounted between monitor and mount for flat screen monitor holder Variable 3-level height adjustment via multiple pre-drilled mounting holes Two rows of mounting holes for use with equipment meeting VESA 75 and VESA 100 standards Keyboard shelf inclined by about 30 for comfortable and ergonomic usability Keyboard shelf with 11-mm folded edging to prevent falling, including handle Variable 2-level depth attachment for keyboard shelf (252/276 mm) Extra-wide keyboard shelf (640 mm) can accommodate a mouse as well Depth of keyboard shelf 172 mm Includes two cable clips for guiding and bundling cables Maximum load 10 kg Dimensions (HxWxD) 360 x 640 x 276 mm Lucas Nülle GmbH Page 103/118

104 171 Protection cover for three-level experiment trolleys ST8010-9Y 1 Dust cover for three-level experiment trolleys For protecting equipment from dust and damp For keeping equipment out of sight (the cover must not be transparent, so is therefore opaque) Colour: matt dark grey with printed LN logo in orange) Material: nylon fabric with polyurethane coating High resistant to tearing, impregnated to be washable and waterproof Lucas Nülle GmbH Page 104/118

105 EUL 8 Load-dependent voltage regulation of a power transmission line EUL 8 Load-dependent voltage regulation of a power transmission line In this experiment the response of a three-phase variable transformer connected up as an autotransformer is investigated operating in conjunction with a power transmission line model including connected load. Due to the enormous increase in photovoltaically generated electricity being fed to the low-voltage power grid, in some areas there is a lot of fluctuation under changing conditions of sunlight and loading. Such fluctuations can be compensated for with the help of a controllable local grid. Training content: Voltage range of a three-phase variable transformer in autoconnected regulating configuration No-load and short-circuit response of the autotransformer Combination of three-phase variable transformer and line model including connected load Automatic voltage adjustment for random load currents Step-up transformer Step-down transformer Lucas Nülle GmbH Page 105/118

106 Supplement to basic set, consisting of: Supplement to basic set, consisting of: Pos. Product name Bestell-Nr. Anz. 172 Three-phase variable transformer with motor drive CO3301-3P 1 The purpose of this controllable transformer is to compensate for the fluctuations in voltage output from power transformers which arise from changes in load. It achieves this by modifying the transformation ratio on the side where the voltage is in excess. The component can be used as a step-up or step-down transformer. Control is handled via the inputs for increasing or decrease the voltage, e.g. with the help of the power quality meter (CO5127-1S). Primary: 3x up to 400 V windings Secondary: 3x V, 2 A windings Nominal power: 1000 VA Frequency: 50/60 HZ Vector group: Yan0 24 V input/"increase voltage" button 24 V input/"decrease voltage" button Protection: 1 automatic circuit breaker, (adjustable) Inputs/outputs: 4-mm safety sockets Dimensions: 297 x 456 x 150 mm Weight: 10 kg Media: Pos. Product name Bestell-Nr. Anz. 173 Interactive Lab Assistant: High-voltage transmission lines SO2800-6K 1 The experiment instructions come in the form of an Interactive Lab Assistant course. This multimedia course is a step-by-step guide through the topic of modern energy systems. The fundamentals are conveyed using easy to understand animations. The Interactive Lab Assistant in conjunction with the SCADA Viewer constitutes a comfortable experimenting environment. Special features: Interactive experiment setups Measured values and diagrams can be stored in the experiment instructions per drag and drop The SCADA Viewer can be started directly from the experiment instructions Lucas Nülle GmbH Page 106/118

107 Includes questions with feedback and evaluation logic for progress monitoring Documents can be printed out for hardcopy of experiment instructions including solutions CD-ROM with Labsoft browser, course software and SCADA Viewer Training contents: Studies of three-phase lines Voltage increases on open-circuit lines Voltage drop as a function of line length Voltage drop as a function of cos phi Capacitive and inductive power losses on a line as a function of V and I Phase shift on a line Parallel and series connection of transmission lines Distribution of power and current among parallelconnected lines of equal length Distribution of power and current among parallelconnected lines of unequal length Distribution of power and current among series-connected lines of equal length Distribution of power and current among series-connected lines of unequal length Load distribution, power flow Voltage distribution Quantitative and qualitative evaluations of operational relationships Study of lines with earth-fault compensation Earth fault on a line with an isolated star point Response to earth faults Earth-fault compensation Studies on power transmission systems with synchronous generators Power and current distribution in a line network fed by a generator Parallel operation of a generator and line via the network Control of active power feed Control of reactive power feed Investigations on three phase cables Lucas Nülle GmbH Page 107/118

108 Ferranti effect, charging capacity, critical length Resistive, inductive and resistive-inductive mixed loads Compensation for a resistive-inductive load Determining zero impedance Symmetric and asymmetric shorts Dealing with star points and shorts to earth Combined networks of cables and lines Differences between cables and transmission lines Investigation of connections: - Transmission lines, transformers and cables - Cables, transformers and transmission lines Losses from individual components Parameters for sub-stations Controlling flow of power in meshed networks Variable transformers Transformer with in-phase regulation (in-phase booster) Transformer with regulation in quadrature (quadrature booster) Phase-angle-regulating transformer (phase-shifting transformer) Affect flow of power via two identical conductors parallel to one another Course duration 22 h approx. Software: Lucas Nülle GmbH Page 108/118

109 Pos. Product name Bestell-Nr. Anz. 174 Software SCADA Viewer SO4001-3H 1 The 'SCADA Viewer' is a software program used for the control and monitoring of power engineering systems. With the software it is possible to display all measured values and operating states inside the system in real time on the existing measuring instruments. Important parameters and signals can be controlled by the software. The measured values and operating states of the equipment can be selected, recorded and plotted over time, evaluated and then exported. Using the 'SCADA Viewer' projects in power engineering are not only made transparent but readable. Software functions: Display of measured values and operating states in real time Plotting of measured values over time in diagrams Processing, analyzing and exporting of diagrams The SCADA viewer contains more than 20 predefined projects Many projects designed with the SCADA designer can be individually expanded at will 175 Patch cable Cat5E 1x 1m yellow, 2x 2m yellow LM x 1m yellow 2x 2m yellow Lucas Nülle GmbH Page 109/118

110 176 USB Network Adapter 10/100 BaseTX RJ45 LM USB-Ethernet adapter provides simple network access without having to install expansion card. The adapter is thus well-suited especially for cases where there are no more slots available in the PC or the housing should not be opened. This adapter is also an alternative for notebooks: instead of a PC card with an Ethernet port the adapter offers a universal connection option for all PCs with USB interface. USB 2.0 high-speed device Downward compatible with USB 1.1 and 1.0 Host controllers Compatible with IEEE 802.3u, 10/100 Base-T and TX Supports both full and half-duplex mode on Ethernet interface Operating systems: Windows ME/200/XP/Vista,7 (32+64 Bit), Linux, Mac OS 10.x Port Ethernet Switch LM Port Ethernet Switch 5 RJ45 terminals Power supply Lucas Nülle GmbH Page 110/118

111 Power supply: Pos. Product name Bestell-Nr. Anz. 178 Adjustable 3-phase power supply, 0-450V/2A CO3301-3Z 1 Controllable 3-phase power supply unit /450V for continuous 3-phase supply Power connection: 230/400V, 50/60Hz Output voltage: 3x V, 50/60Hz variable by means of 3- phase regulating transformer (tolerance 0.5%) DC output V Output current: 2.0A 4-mm safety sockets (L1, L2, L3, N, PE, L-, L+) 1 Voltmeter, V (moving iron instrument) 1 Ammeter, 0...3A (moving iron instrument) 3 Phase control lights 1 Measuring point selector switch. L1-N, L2-N, L3-N, L1-L2, L1-L3, L2-L3 1 Measuring point selector switch. I1, I2, I3 Protection: 3 thermo-magnetic device circuit breakers, Motor protection switch adjustable from A with undervoltage trip Table-top housing with fold-away stand Dimensions: 175 x 370 x 260mm (HxWxD) Weight: 15kg 179 Multiple socket outlet, 6 fold, with illuminated switch ST8010-4J 2 Multiple socket outlet, 6 fold, with illuminated switch, 2 pole 6 earth pin sockets acoording to DIN49440, 250V~,16A power cord 1,5m Dimensions: 439 x 60 x 44mm (LxWxH) Lucas Nülle GmbH Page 111/118

112 Measuring instruments: Pos. Product name Bestell-Nr. Anz. 180 Three-phase power quality meter, display and long-term memory CO5127-1S 2 The three-phase measuring instrument permits the measurement and display of relevant power network parameters. It is able to measure single, two-phase or three-phase measurements. The display and operation is carried out by means of menu navigation with an LC display or the integrated Ethernet interface. The optional SCADA software provides for the display of all measurements and allows the implementation and analysis of intelligent networks (smart grids). The smart meter acts as a digital electricity meter where end customers are connected to the grid in order to measure electricity consumption and can be used to turn consumers on or off depending on the circumstances. Three-phase measurement of current and voltage 3x400V/5A Measurement of phase voltages, line-to-line voltages and currents Determination of the apparent, active and reactive power Determination of active, reactive and apparent work Determination of the frequency and distortion factors for current and voltage Detection of harmonic oscillations and neutral conductor current in the electricity supply Pulse measurement Peak and mean value detection Event logging Real-time clock Large-scale, contrast-rich graphic display with background illumination Display in tables, diagrams and vector diagrams 2 Digital inputs and outputs for free configuration including functions Ethernet interface Menu navigation in German/English/ French/Spanish/Italian/Portuguese/Turkish/ Chinese/Russian/Polish Demonstration measuring instrument for making measurements on the electricity supply grid Max. measurement values: Voltage P-P: 690 V Current: 5 A Fault tolerances: Voltage 0.2% Current 0.2% Apparent power 0.5% Active power 0.2% Reactive power 1% Active energy Class 0.2 Reactive energy Class 2 Operating voltage: 110V-230V, 50/60Hz Dimensions: 297 x 228 x 140mm (HxWxD) Weight: 2kg Lucas Nülle GmbH Page 112/118

113 Accessories: Pos. Product name Bestell-Nr. Anz. 181 Safety connecting plug 4mm with tap (2x), black, 1000V/32A CAT II SO5126-3R 40 Moulded insulation both sides with touch protection (safety plug + safety sockets), distance 19mm transition resistance max. 6mΩ rated data: 1000V/32A CAT II colour black 182 Safety connecting plug 4mm with tap (2x), blue, 1000V/32A CAT II SO5126-3V 2 Moulded insulation both sides with touch protection (safety plug + safety sockets), distance 19mm transition resistance max. 6mΩ rated data: 1000V/32A CAT II colour blue 183 Safety connecting plug 4mm with tap (2x), green/yellow, 1000V/32A CAT II SO5126-3W 7 Moulded insulation both sides with touch protection (safety plug + safety sockets), distance 19mm transition resistance max. 6mΩ rated data: 1000V/32A CAT II colour green/yellow Lucas Nülle GmbH Page 113/118

114 184 Set of safety measurement cables, 4mm (31 leads) SO5148-1L 1 Safety measurement cables with 4mm safety plugs, coloured, PVC insulation, highly flexible Each set includes the following: 6 x 25cm long, black 4 x 50cm long, black 2 x 100cm long, blue 2 x 100cm long, red 1 x 100cm long, green/yellow 1 x 150cm long, blue 1 x 150cm long, green/yellow 2 x 150cm long, green 4 x 150cm long, brown 4 x 150cm long, black 4 x 150cm long, grey Wire cross section 2.5 mm ² Capacity/category: 600V CAT II, 32A 185 Safety measurement cable (4mm), 50cm, black SO5126-8L 6 Safety measurement lead with stackable, contact-proof 4mm plugs Colour: black Length: 50 cm Wire cross section 2.5 mm Safety measurement cable (4mm), 25cm/10", black SO5126-8B 3 Safety measurement lead with stackable, contact-proof 4mm plugs colour: black length: 25 cm cable cross-section 2,5 mm 2 ratings deliver: 600V CAT II, 32A Lucas Nülle GmbH Page 114/118

115 187 Mobile aluminium experiment stand, 3 levels, power strip with 6 sockets, 1250x700x1995mm ST7200-3A 1 High-quality, mobile experiments stand from the SybaPro range for demonstrations and experiments. Features aluminium profile legs compatible with all add-ons and extensions for the SybaPro system. The mobile experiment stand is supplied in kit form and needs to be assembled by customers themselves. Table top: Frame: Dimensions: 30-mm table top made of highly compressed, multi-layer fine chipboard conforming to DIN EN Colour grey, RAL 7035, with 0.8-mm slightly textured laminate coating (Resopal) on both sides, conforming to DIN Resistant to many chemicals and reagents including dilute acids and alkalis Resistant to heat, e.g. molten solder or heating at specific points such as by soldering tips or cigarette ends Table top with solid impact-resistant protective edging made of 3mm thick RAL 7047 coloured plastic Coating and adhesive are PVC free Power strip with 6 outlet sockets mounted underneath the table top, lead and earthed plug 2 extruded aluminium profiles with multiple grooves 1800 x 120 x 40 mm (WxHxD) 8 equally sized grooves in extruded aluminium profiles (3 on each side and 1 each on the front and back) Grooves accommodate standard industrial mountings 4 H-shaped aluminium profiles, 1150 mm, for 3-layer organisation of DIN A4 panels Space for extension of power supply duct Base made of rectangular tubing with 4 swiveling double casters, 2 of which have brakes Table frame made of tough combination of rectangular tubing around the full perimeter Acid-resistant epoxy-resin coating, 80 µm thick (approx.), colour RAL 7047 Height of table top 760 mm 1250 x 1995 x 700 mm (WxHxD) Lucas Nülle GmbH Page 115/118

116 188 Protected power distribution for working stations ST8008-8M V CEE distribution panel with automatic circuit breakers for attachment to profiles on experiment trolleys or direct to table-top. 2 CEE sockets (400 V, 16 A, 5-pole) with safety flap 1 Socket outlet with earth (230 V) plus safety flap Circuit breaker: 1 x 3-pole line circuit breaker, type B, 16 A Power connection: 3 x 230/400 V, 50/60 Hz via CEE plug, 4-m power lead Dimensions: 530 x 130 x 110 mm (HxWxD) Weight: 3 kg 189 Wall or aluminium-profile mounting cable storage for 48 cables ST8003-8E 1 Accommodates about 48 safety measuring leads (4mm), suitable for mounting on walls or aluminium profiles Width 200 mm, 12 guide grooves for leads Adjustable height for mounting on aluminium profiles Can be mounted on the left or right Can be mounted on walls Includes 2 screws and tenon blocks Acid-resistant epoxy-resin powder coating, thickness 80 µm approx., colour RAL PC holder for SybaPro experiment trolleys, height/width adjustable ST7200-5A 1 Shelf for desktop PC made of 1.5mm sheet steel punched with holes, suitable for all furniture in the SybaPro aluminium profile range Adjustable assembly height Adjustable width ( mm) Can be mounted to left or right Includes all equipment necessary for assembly (4 bolts and 4 tenon blocks) Acid-resistant epoxy-resin powder coating, 80µm thick approx., colour RAL7047 Lucas Nülle GmbH Page 116/118

117 191 Monitor holder for flat screen monitor of weight up to 15kg / 33lbs ST8010-4T 1 Pivoting monitor holder for attachment to aluminium profiles of furniture in the SybaPro range. Allows a monitor to be placed in the optimum position so that work and experiments are less tiring. Pivoting arm with two-part joint Quick-lock for adjustment to any height on extruded aluminium profile VESA fastening 7.5 x 7.5cm Includes VESA 75 (7.5x7.5) - VESA 100 (10x10) adapter 2 Cable clips Adequate carrying capacity 15kg / 33lbs TFT monitor can be turned parallel to the table edge Separation can be adjusted to anywhere between 105 and 480mm Additionally included: Cable management set for installing cables along the profiles of the aluminium lab system furniture in the SybaPro range, consisting of: 3 Cross cable binders for front and rear grooves of aluminium profile 3 Cross cable binders for side grooves of aluminium profile 12 Cable binders 4 Aluminium cover profiles for covering and enabling wires to be run along the grooves of an aluminium profile 192 Keyboard adapter for flat screen monitor holders ST8010-4G 1 Keyboard adapter for use in combination with flat screen monitor holders Mounted between monitor and mount for flat screen monitor holder Variable 3-level height adjustment via multiple pre-drilled mounting holes Two rows of mounting holes for use with equipment meeting VESA 75 and VESA 100 standards Keyboard shelf inclined by about 30 for comfortable and ergonomic usability Keyboard shelf with 11-mm folded edging to prevent falling, including handle Variable 2-level depth attachment for keyboard shelf (252/276 mm) Extra-wide keyboard shelf (640 mm) can accommodate a mouse as well Depth of keyboard shelf 172 mm Includes two cable clips for guiding and bundling cables Maximum load 10 kg Dimensions (HxWxD) 360 x 640 x 276 mm Lucas Nülle GmbH Page 117/118

Table of Contents. Lucas Nülle GmbH Page 1/19

Table of Contents. Lucas Nülle GmbH Page 1/19 Table of Contents Table of Contents Electrical Power Engineering, Smart Grid Trainers Power transmission ELP Protective systems for high-voltage transmission lines ELP 3 Overvoltage and undervoltage protection

More information

Table of Contents. 1 Electrical Power Engineering, Smart Grid Trainers. 2 Renewable Energies. 2 EPH 3 Professional Photovoltaics Trainer (PV)

Table of Contents. 1 Electrical Power Engineering, Smart Grid Trainers. 2 Renewable Energies. 2 EPH 3 Professional Photovoltaics Trainer (PV) Table of Contents Table of Contents 1 Electrical Power Engineering, Smart Grid Trainers 2 Renewable Energies 2 EPH 3 Professional Photovoltaics Trainer (PV) 3 EPH 3.1 Investigation of solar modules 4 EPH

More information

Table of Contents. 1 Power Electronics / Electrical Machines / Drive Technology. 2 EEM Electrical machines 1kW. 2 EEM 4-1 Asynchronous machines 1kW

Table of Contents. 1 Power Electronics / Electrical Machines / Drive Technology. 2 EEM Electrical machines 1kW. 2 EEM 4-1 Asynchronous machines 1kW Table of Contents Table of Contents 1 Power Electronics / Electrical Machines / Drive Technology 2 EEM Electrical machines 1kW 2 EEM 4-1 Asynchronous machines 1kW 3 EEM 4.2-1 Three-phase induction motor

More information

Table of Contents. Lucas Nülle GmbH Page 1/44

Table of Contents. Lucas Nülle GmbH Page 1/44 Table of Contents Table of Contents Power Electronics / Electrical Machines / Drive Technology EEM Electrical machines 300W EEM 11-3 Energy-saving drives 300W EEM 11.1-3 Energy efficient drive design 300W

More information

Table of Contents. Lucas Nülle GmbH Page 1/17

Table of Contents. Lucas Nülle GmbH Page 1/17 Table of Contents Table of Contents Power Electronics / Electrical Machines / Drive Technology EPE Power electronics and drives 300W Drives EPE 43-3 Converter drives with DC motor 300W 1 2 2 3 4 Lucas

More information

Table of Contents. 1 Power Electronics / Electrical Machines / Drive Technology. 2 Designing drive controllers with MATLAB - Simulink 1kW

Table of Contents. 1 Power Electronics / Electrical Machines / Drive Technology. 2 Designing drive controllers with MATLAB - Simulink 1kW Table of Contents Table of Contents Power Electronics / Electrical Machines / Drive Technology 2 Designing drive controllers with MATLAB - Simulink kw 2 EPE 53- DC drives with cascade control using MATLAB

More information

Table of Contents. 1 Automation Technology. 2 Automation technology. 2 Automation technology with Siemens PLC

Table of Contents. 1 Automation Technology. 2 Automation technology. 2 Automation technology with Siemens PLC Table of Contents Table of Contents 1 Automation Technology 2 Automation technology 2 Automation technology with Siemens PLC 3 CLC 30 Fundamentals of programmable logic controls using the SIMATIC S7-300

More information

Table of Contents. Lucas Nülle GmbH Page 1/17

Table of Contents. Lucas Nülle GmbH Page 1/17 Table of Contents Table of Contents Building management systems Building management systems EIT 10 Smart Homes EIT 10 Smart homes using Z-Wave / ZigBee 1 2 2 4 5 Lucas Nülle GmbH Page 1/17 www.lucas-nuelle.us

More information

Table of Contents. 1 Building Management. 2 Building management systems. 2 EIT 8 Wiring installation using Instabus KNX

Table of Contents. 1 Building Management. 2 Building management systems. 2 EIT 8 Wiring installation using Instabus KNX Table of Contents Table of Contents 1 Building Management 2 Building management systems 2 EIT 8 Wiring installation using Instabus KNX 3 EIT 8.1 Lighting and blind/shutter control using KNX 5 EIT 8.2 Special

More information

Table of Contents. Lucas Nülle GmbH Page 1/55

Table of Contents. Lucas Nülle GmbH Page 1/55 Table of Contents Table of Contents Electrical Power Engineering, Smart Grid Trainers Basics of electrical power engineering Fundamentals of power engineering (UniTrain) EUB Current and voltage transformers

More information

Table of Contents. Lucas Nülle GmbH Page 1/29

Table of Contents. Lucas Nülle GmbH Page 1/29 Table of Contents Table of Contents Building management systems Building management systems EIT 8 Wiring installation using Instabus KNX EIT 8.1 Lighting and blind/shutter control using KNX/EIB EIT 8.2

More information

Table of Contents. Lucas Nülle GmbH Page 1/252

Table of Contents. Lucas Nülle GmbH Page 1/252 Table of Contents Table of Contents Electrical Power Engineering, Smart Grid Trainers Basics of electrical power engineering Fundamentals of power engineering (UniTrain) EUB Current and voltage transformers

More information

Table of Contents. Table of Contents Building management systems InsTrain wiring installation training system EGT 4 KNX/EIB bus systems

Table of Contents. Table of Contents Building management systems InsTrain wiring installation training system EGT 4 KNX/EIB bus systems Table of Contents Table of Contents Building management systems InsTrain wiring installation training system EGT 4 KNX/EIB bus systems 1 2 2 5 Lucas Nülle GmbH Page 1/16 www.lucas-nuelle.com Building management

More information

Table of Contents. Table of Contents Microcomputers Microcontroller Technology using the 32-Bit ARM Cortex M3

Table of Contents. Table of Contents Microcomputers Microcontroller Technology using the 32-Bit ARM Cortex M3 Table of Contents Table of Contents Microcomputers Microcontroller Technology using the 32-Bit ARM Cortex M3 1 2 2 Lucas Nülle GmbH Page 1/9 www.lucas-nuelle.com Microcomputers Training systems on microcontroller

More information

InForm Superstructures

InForm Superstructures Advantages InForm racks are fitted between the vertical profiles and thus ensure a generous amount of open working table surface. Devices are installed directly in the 3HU and 6HU racks, additional devices

More information

Table of Contents. Lucas Nülle GmbH Page 1/9

Table of Contents. Lucas Nülle GmbH Page 1/9 Table of Contents Table of Contents Automation / Industry 4.0 IMS Industrial mechatronics system Mechatronics Sub-Systems with UniTrain IMS 10 Buffering 1 2 2 4 5 Lucas Nülle GmbH Page 1/9 www.lucas-nuelle.us

More information

SybaLab. The Laboratory Equipment Range from Lucas-Nülle

SybaLab. The Laboratory Equipment Range from Lucas-Nülle SybaLab The Laboratory Equipment Range from Contents Laboratory Systems for Education and Training, Changing with the Times... 4 We Represent Quality Certification to ISO 9001:2000... 5 Educational Concepts

More information

Table of Contents. Lucas Nülle GmbH Page 1/36

Table of Contents. Lucas Nülle GmbH Page 1/36 Table of Contents Table of Contents Automation Technology Automation technology Automation technology with Siemens PLC Operating and Monitoring CBS 1 Industrial bus systems CID 1 - RFID CLP 20 Open-loop

More information

InForm Superstructures

InForm Superstructures Advantages InForm racks are fitted between the vertical profiles and thus ensure a generous amount of open working table surface. Devices are installed directly in the 3HU and 6HU racks, additional devices

More information

Service poles for industrial applications

Service poles for industrial applications Service poles for industrial applications Ready to go. The ISS basic profile Our industry service poles bundle power, data and compressed air in a compact and robust manner. This means relocations, for

More information

Electromechanical Systems Simulation Software (LVSIM -EMS)

Electromechanical Systems Simulation Software (LVSIM -EMS) Electromechanical Systems Simulation Software (LVSIM -EMS) LabVolt Series Datasheet Festo Didactic en 04/2018 Table of Contents General Description 2 Virtual Instrumentation 3 Metering Window 4 Oscilloscope

More information

3,600 W to 10,800 W 120 V to 800 V 22.5 A to 330 A

3,600 W to 10,800 W 120 V to 800 V 22.5 A to 330 A 3,600 W to 10,800 W 120 V to 800 V 22.5 A to 330 A 2 Electronic Energy Recycling Load ERI Series Syntax Interface Overview RS-232 USB LAN GPIB O CAN Analog Analog isolated O Standard O Option /not available

More information

Accessories for control enclosures. BERNSTEIN attachment solutions. Double coupling head (console version with suspension system attachment)

Accessories for control enclosures. BERNSTEIN attachment solutions. Double coupling head (console version with suspension system attachment) 25 Accessories for control enclosures BERNSTEIN attachment Single coupling head (suspended console version) Double coupling head (console version with suspension system attachment) 322.5 231 232 140 The

More information

LSFC Power Factor Correction Systems

LSFC Power Factor Correction Systems LSFC Ready to connect, automatic in sheet steel cabinets for floor installation. Suitable for networks without harmonic distortion. Power Range: 100 to 00 kvar Modular construction in freestanding sheet

More information

5. Office furniture. 5. Office furniture. Laboratory furniture. Flexible and customised

5. Office furniture. 5. Office furniture. Laboratory furniture. Flexible and customised 5. Office Flexible and customised 5. Office Laboratory Your laboratory staff needs a thoughtfully planned office or work area and we have just the you have been looking for. Functional and customised to

More information

200 VA bis VA 10 V bis 80 V 2 A bis 320 A. Source-Sink NL

200 VA bis VA 10 V bis 80 V 2 A bis 320 A. Source-Sink NL 200 VA bis 3.120 VA 10 V bis 80 V 2 A bis 320 A NL AC, NL Series Interface overview RS-232 X USB X GPIB O LAN O System bus O Analog X Analog isolated O X Standard O Option / not available NL1V20C40 2-quadrant

More information

Motor Winding Kit. LabVolt Series. Datasheet

Motor Winding Kit. LabVolt Series. Datasheet Motor Winding Kit LabVolt Series Datasheet Festo Didactic en 240 V - 50 Hz 07/2018 Table of Contents General Description 2 Optional Equipment Required to Operate the Rotating Machines 3 Features & Benefits

More information

DRTS 3 PLUS Advanced Protection Relay Test Set and Measurement System

DRTS 3 PLUS Advanced Protection Relay Test Set and Measurement System Advanced Protection Relay Test Set and Measurement System Multi-tasking equipment designed for testing protection relays, energy meters, transducers Particularly designed to test RTU (remote terminal unit)

More information

IT power distribution Power distribution units (PDU) Basic. Versions available:

IT power distribution Power distribution units (PDU) Basic. Versions available: IT PDU Basic 1 U With its IT PDU Basic 1 U, BACHMANN provides a huge choice of PDUs in a high-quality aluminium profile. With their extremely compact size of just 1 height unit, mm in depth and 1" in width,

More information

Sivacon S4. Low-Voltage Switchboards. siemens.co.uk/tip

Sivacon S4. Low-Voltage Switchboards. siemens.co.uk/tip Product Managers and dedicated Business Development Managers are available to assist with all your enquiries. Technical presentations (Forms of Separation, Discrimination etc) available Site response capability

More information

REGENERATIVE LOAD ERI SERIES

REGENERATIVE LOAD ERI SERIES Electronic DC Loads REGENERATIVE LOAD ERI SERIES The electronic loads of the ERI series feed the absorbed energy back into the local supply network. This protects the environment and reduces electricity

More information

Table of Contents. Table of Contents Communications Technology Professional practice Professional practice WLAN TWT 1 WLAN trainer SOHO

Table of Contents. Table of Contents Communications Technology Professional practice Professional practice WLAN TWT 1 WLAN trainer SOHO Table of Contents Table of Contents Communications Technology Professional practice Professional practice WLAN TWT 1 WLAN trainer SOHO 1 2 2 3 3 Lucas Nülle GmbH Page 1/7 www.lucas-nuelle.com Communications

More information

XL 4000 metal free-standing enclosures and cable compartments

XL 4000 metal free-standing enclosures and cable compartments 87045 LIMOGES Cedex Telephone : 05 55 06 87 87 Fax : 05 55 06 88 88 XL metal free-standing enclosures and CONTENTS PAGE 1. General characteristics...1 2. Range...2 3. Overall dimensions...2 4. Equipment...3

More information

Description. Monitoring functions Evaluation of brush length monitoring, digital, non-floating A00

Description. Monitoring functions Evaluation of brush length monitoring, digital, non-floating A00 Monitoring functions Evaluation of brush length monitoring, digital, non-floating Evaluation of brush length monitoring, digital, floating A00 A06 Non-floating brush length monitoring with use of KM01

More information

ATV1200A kv kva. Phase-shifting transformer Medium voltage arrestors Cooling fans Human machine interface Plinth (2) Power cells (9)

ATV1200A kv kva. Phase-shifting transformer Medium voltage arrestors Cooling fans Human machine interface Plinth (2) Power cells (9) Characteristics medium voltage variable speed drive ATV1200-3.3 kv - 370 kva Main Range of product Altivar 1200 Product or component type Device short name Product destination Product specific application

More information

Motor Winding Kit

Motor Winding Kit 8022-05 Motor Winding Kit LabVolt Series Datasheet Festo Didactic en 220 V - 50 Hz 04/208 Table of Contents General Description 2 Optional Equipment Required to Operate the Rotating Machines 3 Features

More information

ATV1200A kv kva

ATV1200A kv kva Characteristics medium voltage variable speed drive ATV1200-3.3 kv - 3500 kva Main Range of product Altivar 1200 Product or component type Device short name Product destination Product specific application

More information

Elabo TaMo. Mobile carrier system for industrial use

Elabo TaMo. Mobile carrier system for industrial use Elabo TaMo Mobile carrier system for industrial use Elabo TaMo Modular carrier system M-Frame TaMo is conceived modularly. The M-frame basic carrier consists of the pivoting casters, the bottom plate which

More information

ATV1200A kv kva

ATV1200A kv kva Characteristics medium voltage variable speed drive ATV1200-10 kv - 5000 kva Main Range of product Altivar 1200 Product or component type Device short name Product destination Product specific application

More information

sonnen Installation Practical

sonnen Installation Practical sonnen Installation Practical sonnen Components sonnenbatterie eco 8.0 Single Phase System Components 4 sonnenbatterie eco 8.0 Single Phase System Components 5 sonnenbatterie eco 8.0 Single Phase System

More information

Specification Sheet: HT SERIES

Specification Sheet: HT SERIES Specification Sheet: HT SERIES HT Series: High Specification 19 Enclosures Hi-tech Series of 19 enclosures, supplied in self assembly (flat pack) format for ease of transportation and storage. Manufactured

More information

MIC-2 MKII, Multi-instrument DATA SHEET

MIC-2 MKII, Multi-instrument DATA SHEET MIC-2 MKII, Multi-instrument DATA SHEET Measurements All 3-phase AC measurements True RMS 4-Quadrant energy Power Quality Analysis Replaces analogue meters RS-485 Modbus RTU protocol TCP/IP Modbus (optional)

More information

A2000 Multifunctional Power Meter

A2000 Multifunctional Power Meter 3-348-980-03 3/12.99 Capable of communications via Profibus-DP, LONWORKS interface or RS 485 interface (depending upon model) Measurement of current, voltage, active, reactive and apparent power, power

More information

Current Transformer Fundaments for Protection Devices AEL-CTFP

Current Transformer Fundaments for Protection Devices AEL-CTFP Engineering and Technical Teaching Equipment Current Transformer Fundaments for Protection Devices AEL-CTFP Key features: Advanced Real-Time SCADA. Open Control + Multicontrol + Real-Time Control. 1 Unit:

More information

Manual Reactive Power Compensation AEL-MRPC. Technical Teaching Equipment. Key features: For more information about Key Features, click here

Manual Reactive Power Compensation AEL-MRPC. Technical Teaching Equipment. Key features: For more information about Key Features, click here Manual Reactive Power Compensation Technical Teaching Equipment AEL-MRPC Key features: Advanced Real-Time SCADA. Open Control + Multicontrol + Real-Time Control. 1 Unit: AEL-MRPC. Manual Reactive Power

More information

EcoTec SP tables and base cabinets

EcoTec SP tables and base cabinets Shapes and colours Tabletops and furniture surfaces Table superstructures, base cabinets and handles 30 mm panel with replaceable edge, Antistatic, light grey 30 mm panel with impact-resistant edge band

More information

A COMPACT GUIDE TO SAFETY TESTING: PROTECTION CLASSES

A COMPACT GUIDE TO SAFETY TESTING: PROTECTION CLASSES TEST EQUIPMENT OVERVIEW OF Mobile Test Panels Series PMK 2 PMK 3 PMK 4 PMKD 2500 Rated current 16 A 32 A Mains connection optionally via 2m each Earthed safety plug Earthed safety plug optionally via 2m

More information

Applications : LA-51-1 LA-52-1 LA-51-2 LA Features : LA-51-3 LA-52-3 LCD SUPPORTER KEYBOARD ARM

Applications : LA-51-1 LA-52-1 LA-51-2 LA Features : LA-51-3 LA-52-3 LCD SUPPORTER KEYBOARD ARM Applications : It goes well with partition boards and tracks in an office, or Medicine table at a dentist, or Medical equipment at a clinic or mobile cart, or Industrial machinery or monitor system at

More information

Directional Overcurrent Protection for Transmission Lines AEL-TPT-02

Directional Overcurrent Protection for Transmission Lines AEL-TPT-02 Technical Teaching Equipment Directional Overcurrent Protection for Transmission Lines AEL-TPT-02 Key features: Advanced Real-Time PSV-SCADA. 1 Unit: AEL-TPT-02. Directional Overcurrent Protection for

More information

ELR W1/ 6-24DC. Extract from the online catalog. Order No.:

ELR W1/ 6-24DC. Extract from the online catalog. Order No.: Extract from the online catalog ELR W1/ 6-24DC Order No.: 2982090 Illustration shows item ELR W1/ 6-24DC Electronic reversing load relay, for driving DC motors, with light indicator and protection circuit,

More information

DRTS 64. The new generation of advanced test equipment for Relays, Energy meters, Transducers and Power quality meters.

DRTS 64. The new generation of advanced test equipment for Relays, Energy meters, Transducers and Power quality meters. The new generation of advanced test equipment for Relays, Energy meters, Transducers and Power quality meters Testing all relay technologies: electromechanical, solid state, numerical and IEC61850 Manual

More information

Modular Terminal Blocks and Terminal Strips with CAGE CLAMP, Series 260 to 262, Side-Entry

Modular Terminal Blocks and Terminal Strips with CAGE CLAMP, Series 260 to 262, Side-Entry 36 Modular Terminal Blocks and Terminal Strips with CAGE CLAMP, Series 260 to 262, Side-Entry Assembly Assembly of modular terminal blocks to terminal strips Mounting of an end plate screw fixing CAGE

More information

UniTrain-I System. Instruction manual. SO4203-2A Interface SO4203-2B Experimenter. 4 th Edition. UniTrain-I System

UniTrain-I System. Instruction manual. SO4203-2A Interface SO4203-2B Experimenter. 4 th Edition. UniTrain-I System Instruction manual UniTrain-I System SO4203-2A Interface SO4203-2B Experimenter 4 th Edition www.lucas-nuelle.com www.unitrain-i.com LUCAS-NÜLLE GmbH Siemensstraße 2 D-50170 Kerpen Contents Preface...

More information

454 PHOENIX CONTACT Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA

454 PHOENIX CONTACT Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 454 PHOENIX CONTACT and feed-through terminal blocks The more varied the tasks in electrical engineering, the more varied the components for the solution have to be. The industrial connection technology

More information

DEIF A/S. MIC Multi-instrument G. Data sheet. Features. Accuracy. Measurements. Installation. Intelligent. Display. Communication DEIF A/S

DEIF A/S. MIC Multi-instrument G. Data sheet. Features. Accuracy. Measurements. Installation. Intelligent. Display. Communication DEIF A/S Multi-instrument 4921210107G Features Measurements All 3-phase AC measurements True RMS Replaces analogue meters Intelligent Suitable for all 3-phase network topologies Replaces transducers Accuracy U,

More information

2 in 1 LAN Tester and Multimeter Model:

2 in 1 LAN Tester and Multimeter Model: 2 in 1 LAN Tester and Multimeter Model: 72-8495 1 IMPORTANT SAFETY INFORMATION Please read these instructions carefully before use and retain for future reference. This instrument is designed and manufactured

More information

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters Testing all relay technologies: electromechanical, solid state, numerical and IEC61850 Manual

More information

FLEXIBLE SOLUTIONS FOR THE ENERGY INDUSTRY

FLEXIBLE SOLUTIONS FOR THE ENERGY INDUSTRY FLEXIBLE SOLUTIONS FOR THE ENERGY INDUSTRY COMPREHENSIVE INSTRUMENT FOR MEASUREMENT AND CONTROL OF POWER SYSTEMS CENTRAX CU-SERIES CENTRAX CU3000 CENTRAX CU5000 PAGE 2 Comprehensive instrument for measurement

More information

Overvoltage and Undervoltage Protection Relay AEL-TPT-03

Overvoltage and Undervoltage Protection Relay AEL-TPT-03 Technical Teaching Equipment Overvoltage and Undervoltage Protection Relay AEL-TPT-03 Key features: Advanced Real-Time PSV-SCADA. Open Control + Multicontrol + Real-Time Control. 1 Unit: AEL-TPT-03. Overvoltage

More information

ALPHA Small Distribution Boards SIMBOX 63/SIMBOX WP

ALPHA Small Distribution Boards SIMBOX 63/SIMBOX WP ALPHA Small Distribution Boards SIMBOX 63/SIMBOX WP SIMBOX 63 /4 Introduction /5 Flush mounting distribution boards /6 Hollow-wall distribution boards /7 Surface mounting distribution boards /7 Hood-type

More information

LED Driver Linear / area fixed output

LED Driver Linear / area fixed output Driver LC 69W 35-5mA flexc lp ANCED series Product description Built-in constant current LED Driver New version DC operating with EL marking Adjustable output current between 35 and 5 ma Max. output power

More information

LED Driver Linear / area fixed output

LED Driver Linear / area fixed output Driver LC 7W 5-35mA flexc lp ANCED series Product description Built-in constant current LED Driver New version DC operating with EL marking Adjustable output current between 5 and 35 ma Max. output power

More information

Switches and Indicators 84

Switches and Indicators 84 Switches and Indicators 84 84 Switches and Indicators Index Series 84 Description Page 177 Product Assembly Page 178 Mounting Instruction Page 179 Product Range - pushbuttons for flush mounting - accessories

More information

. Modular training system for the fundamentals of digital technology /. . Individual expansion possibilities. Detailed experiment descriptions

. Modular training system for the fundamentals of digital technology /. . Individual expansion possibilities. Detailed experiment descriptions . Modular training system for the fundamentals of digital technology /. microcomputer technology Clear experiment assembly because only the modules required for the. Individual expansion possibilities.

More information

Automatic Reactive Power Compensation AEL-ARPC

Automatic Reactive Power Compensation AEL-ARPC Technical Teaching Equipment Automatic Reactive Power Compensation AEL-ARPC Key features: Advanced Real-Time SCADA. 1 Unit: AEL-ARPC. Automatic Reactive Power Compensation Open Control + Multicontrol +

More information

Slim Relay G2RV. Model Number Structure. Ordering Information. Model Number Legend. List of Models. Relay and Socket Combinations

Slim Relay G2RV. Model Number Structure. Ordering Information. Model Number Legend. List of Models. Relay and Socket Combinations Slim Relay G2RV The World's First Industrial Slim Relay Large plug-in terminals for reliable connection. LED indicator and mechanical flag to check operation. Transparent housing enables checking relay

More information

MODEL: R1M-P4. PC Recorders R1M Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.)

MODEL: R1M-P4. PC Recorders R1M Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.) PC Recorders Series PC RECORDER (4 totalized counter inputs, 8 contact inputs and outputs) Functions & Features Industrial recorder on PC Totalized counter inputs Counts stored in E 2 PROM Easy system

More information

Demonstration Case BENNING DB 1

Demonstration Case BENNING DB 1 Operating manual Demonstration Case BENNING DB 1 part no. 044132 Table of contents 1 Introduction...3 2 Safety instructions...4 3 Applicable regulations...5 4 Device description...5 4.1 Measuring / testing...

More information

We take care of it. Mobile Power Quality Analyzers. PQ-Box 100/150/200. Accessories

We take care of it. Mobile Power Quality Analyzers. PQ-Box 100/150/200. Accessories We take care of it. Mobile Power Quality Analyzers PQ-Box 100/150/200 Accessories Rogowski coil set Current range: 1 A to 3000 A RMS; Set of 4 pieces Accuracy: 1%; Size: 61 cm (24 ); Diameter = 194 mm

More information

MIC-2 Multi-instrument DATA SHEET

MIC-2 Multi-instrument DATA SHEET Measurements All 3-phase AC measurements True RMS 4-Quadrant energy Power Quality Analysis Replaces analogue meters RS-485 Modbus RTU protocol TCP/IP Modbus (optional) Profibus DP (optional) I/O modules

More information

F1000 User's Manual. (Version: V1.01)

F1000 User's Manual. (Version: V1.01) (Version: V1.01) Contents Chapter 1 Overview... 2 Chapter 2 Installation... 3 2.1 Installation guide... 3 2.1.1 Installation position... 3 2.1.2 NEMA4 standard installation... 3 2.1.3 Environment precautions...

More information

Parts List: Part # Tools List: Instructions:

Parts List: Part # Tools List: Instructions: Parts List: Part # 1 pair of Dayton Audio B652s 300-652 1 Dayton Audio DTA-2 amplifier 300-385 1 MP3 module 320-350 1 7805 +5 VDC voltage regulator 7805 1 12 VDC 2A power supply 129-077 1 2.1 mm panel

More information

Building Energy Management Training Systems

Building Energy Management Training Systems Building Energy Management Training Systems 3466-00 LabVolt Series Datasheet Festo Didactic en 120 V - 60 Hz 03/2019 Table of Contents General Description 2 Courseware 2 Topic Coverage 2 List of Available

More information

UMG 511. Class A EN UMG 511 Class A power quality analyzer. according to EN50160, IEEE 519, ITIC, IEC Areas of application

UMG 511. Class A EN UMG 511 Class A power quality analyzer. according to EN50160, IEEE 519, ITIC, IEC Areas of application UMG 511 Class A EN 50160 UMG 511 Class A power quality analyzer according to EN50160, IEEE 519, ITIC, IEC 61000-4-30 The UMG 511 power quality analyzer is particularly suitable for monitoring power quality

More information

Organisational Kitchen Fittings Drawer and Front Extensions

Organisational Kitchen Fittings Drawer and Front Extensions GRASS NOVA PRO TOUCH LATCH SENSO Application: For drawer and front pull-out Material: Steel, plastic, aluminium Finish: Zinc plated, powder coated Opening version: Full extension with self opening mechanism

More information

DC and AC Power Circuits Training System ( )

DC and AC Power Circuits Training System ( ) DC and AC Power Circuits Training System 579281 (8010-10) LabVolt Series Datasheet Festo Didactic en 120 V - 60 Hz 01/2019 Table of Contents General Description 2 Courseware 3 Modular Approach 4 elearning

More information

MIC-2 MKII & MIC-2 MKII DIN, Multi-instrument DATA SHEET

MIC-2 MKII & MIC-2 MKII DIN, Multi-instrument DATA SHEET & DIN, Multi-instrument DATA SHEET Measurements All 3-phase AC measurements True RMS 4-Quadrant energy Power Quality Analysis Replaces analogue meters RS-485 Modbus RTU protocol TCP/IP Modbus (optional)

More information

DRTS 66. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

DRTS 66. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters Testing all relay technologies: electromechanical, solid state, numerical and IEC61850 Manual

More information

for a perfect electrical installation. The range of rail-mounted terminal blocks

for a perfect electrical installation. The range of rail-mounted terminal blocks The range of rail-mounted terminal blocks for a perfect electrical installation. The range of rail-mounted terminal blocks for a perfect electrical installation. The new standard for rail-mounted terminal

More information

DRTS 33. The new generation of advanced three phase relay test set

DRTS 33. The new generation of advanced three phase relay test set The new generation of advanced three phase relay test set Testing all relay technologies: electromechanical, solid state, numerical and IEC61850 Local control with color display Simultaneously available:

More information

AThink future. Switch to green. Mini Panel Board. Cost-effective, space-saving board up to 400A.

AThink future. Switch to green. Mini Panel Board. Cost-effective, space-saving board up to 400A. www.moeller.co.uk Mini Panel Board Cost-effective, space-saving board up to 400A Product Catalogue and Selection Guide Mini Panel Board Miniature Circuit Breakers Moulded Case Circuit Breakers XBoard Consumer

More information

Limanda. Technical data

Limanda. Technical data Polyamide hand held enclosures for data acquisition, MCR and automation engineering 2 sizes - 270 x 248 x 64 mm to 311 x 281 x 72 mm Large fitting area For installations and command devices mobile and

More information

Exercise 2. Single Bus Scheme EXERCISE OBJECTIVE DISCUSSION OUTLINE. The single bus scheme DISCUSSION

Exercise 2. Single Bus Scheme EXERCISE OBJECTIVE DISCUSSION OUTLINE. The single bus scheme DISCUSSION Exercise 2 Single Bus Scheme EXERCISE OBJECTIVE When you have completed this exercise, you will be familiar with electric power substations using the single bus scheme with bus section circuit breakers.

More information

ATV930U30M3 variable speed drive - ATV930-3kW - 200/240Vwith braking unit - IP21

ATV930U30M3 variable speed drive - ATV930-3kW - 200/240Vwith braking unit - IP21 Characteristics variable speed drive - ATV930-3kW - 200/240Vwith braking unit - IP21 Main Range of product Product or component type Device application Device short name Variant Product destination Mounting

More information

References. References. Rating (A) Référence

References. References. Rating (A) Référence DIRECT OPERATION T O O R D E R EXTERNAL OPERATION picto_080_c_1_gb Switch body Direct Switch body + handle + Shaft + + OTHER ACCESSORIES External handle acces_128_a_1_cat acces_129_a_1_cat Direct handle

More information

A P P L I C A T I O N

A P P L I C A T I O N Circuit Breaker timing test set 16 timing channels Motion and speed analyzer Built-in 200 A microohmmeter Up to 4 trip/close coils control Static and dynamic contact resistance measurement Suitable for

More information

FBP FieldBusPlug FBP System Accessories

FBP FieldBusPlug FBP System Accessories FBP FieldBusPlug V6 FBP FieldBusPlug V 6 Please note the following Target group This description is intended for the use of trained specialists in electrical installation and control and automation engineering,

More information

Power supply module, bus connection module

Power supply module, bus connection module s 8 183 8183p01, p02 TX-I/O Power supply module, bus connection module TXS1.12F10 TXS1.EF10 Each I/O row begins with one of these devices TXS1.12F10 power supply module Up to 4 power supply modules can

More information

Surface-Mounting Product Ranges

Surface-Mounting Product Ranges Introduction Overview Light signals SCHUKO socket outlets Two-circuit switches Garages, laundry rooms, laboratories and workshops are often exposed to a lot of heavy-duty activity, which includes the odd

More information

SYSTEM WORLD PRODUCT INFO

SYSTEM WORLD PRODUCT INFO SYSTEM WORLD PRODUCT INFO August 208 System case.. System Case Configuration.. Width x depth x height (inches).56 x 0.62 x 3.3 inches Number of System Boxes Material Lid Type Art. No. Empty* ABS Black

More information

XPSMF35. Product data sheet Characteristics. Preventa safety PLC compact - Profibus DP protocol. Main. Complementary. Safety module name

XPSMF35. Product data sheet Characteristics. Preventa safety PLC compact - Profibus DP protocol. Main. Complementary. Safety module name Product data sheet Characteristics XPSMF3542 Preventa safety PLC compact - Profibus DP protocol Main Range of product Product or component type Safety module name Safety module application Nov 13, 2018

More information

DP2 DOOR PHONE. For Technical Assistance Please Phone: (07)

DP2 DOOR PHONE. For Technical Assistance Please Phone: (07) DP2 DOOR PHONE For Technical Assistance Please Phone: (07) 5596 5128 TABLE OF CONTENTS Description Page 3 Door Phone Dimensions Page 4 Door Phone Range Page 5 Door Phone Performance Page 6 Operation Summary

More information

Part No. Z , IA Mar OPERATION MANUAL. High Voltage Digitalmeter A

Part No. Z , IA Mar OPERATION MANUAL. High Voltage Digitalmeter A Part No. Z1-109-820, IA001704 Mar. 2011 OPERATION MANUAL High Voltage Digitalmeter 149-10A Use of Operation Manual Please read through and understand this Operation Manual before operating the product.

More information

LOW WEIGHT, SMALL SIZE,

LOW WEIGHT, SMALL SIZE, THE LOW WEIGHT, SMALL SIZE, ONE-TOUCH SOLUTION Portable appliance testing The Fluke 6000-2 PAT Testers Fluke 6200-2 and 6500-2 TEST MORE APPLIANCES PER DAY The Fluke 6200-2 and 6500-2 PAT testers verify

More information

MEASURING AND TESTING INSTRUMENTS

MEASURING AND TESTING INSTRUMENTS MEASURING AND TESTING INSTRUMENTS Whether measuring temperature, current or voltage testing the right measuring tool can facilitate the everyday work. If one wants to perform several measuring tasks at

More information

19" TiRAX cabinet system. from page 3. 19" NETcell cabinet system from page 31. Open 19" racks from page 43

19 TiRAX cabinet system. from page 3. 19 NETcell cabinet system from page 31. Open 19 racks from page 43 9" TiRAX cabinet system from page 9" NETcell cabinet system from page Open 9" racks from page Wall-mounting/stand-alone distribution systems from page 5 Wall-mounting enclosure systems from page 6 Air

More information

JUMO TYA 201 Single-Phase SCR Power Controller For controlling resistive/inductive loads

JUMO TYA 201 Single-Phase SCR Power Controller For controlling resistive/inductive loads Data sheet 709061 Page 1/21 JUMO TYA 201 Single-Phase SCR Power Controller For controlling resistive/inductive loads The JUMO TYA 201 represents a consistent further development of the JUMO power controller

More information

Insulated Enclosure KS 4400 with fixed or pluggable screw or cage clamp terminals

Insulated Enclosure KS 4400 with fixed or pluggable screw or cage clamp terminals Insulated Enclosure KS 4400 with fixed or pluggable screw or cage clamp terminals Technical Data Type: KS 4401 KS 4402 KS 4403 KS 4461 KS 4404 KS 440 KS 4406 Article number * ) : 00636 00637 0063987 00614

More information

DRTS 66 can test all the following relays

DRTS 66 can test all the following relays Testing all relay technologies: electromechanical, solid state, numerical and IEC61850 Manual control with color display Simultaneously available: 6 Current and 6 Voltage plus 1 battery simulator outputs

More information

Model KT 53 Cooling incubators with thermoelectric cooling

Model KT 53 Cooling incubators with thermoelectric cooling Model KT 53 Cooling incubators with thermoelectric cooling The KT series combines outstanding performance with impressive energy efficiency and environmental friendliness. The cooled incubators of the

More information