2. Volume II, paragraph 1.2.2: Replace the following first paragraph and Table 1-4: Table 1-4: Number of GWA/SCADA Upgraded Facilities

Size: px
Start display at page:

Download "2. Volume II, paragraph 1.2.2: Replace the following first paragraph and Table 1-4: Table 1-4: Number of GWA/SCADA Upgraded Facilities"

Transcription

1

2 2. Volume II, paragraph 1.2.2: Replace the following first paragraph and Table 1-4: GWA has a few facilities upgraded with supervisory control and data acquisition systems and are presently operating as standalone systems. These existing systems need to be connected and integrated with the new SCADA/EMS system. The communication links will be provided by GPWA. Table 1-4: Number of GWA/SCADA Upgraded Facilities Qty Facilities 1 Wastewater Treatment Plant 1 Water Treatment Plant 11 Deep Wells 2 Reservoirs 15 Total GWA has a few facilities upgraded with supervisory control and data acquisition systems and are presently operating as standalone systems. These existing systems shall be connected and integrated with the new SCADA/EMS system, with exemption of the Water Treatment Plant. The communication links will be provided by GPWA. Table 1-4: Number of GWA Facilities with standalone SCADA systems Qty Facilities 1 Wastewater Treatment Plant 1 Water Treatment Plant 11 Deep Wells 2 Reservoirs 15 Total The Water Treatment Plant will not be included in the scope and price of this bid. This plant will be integrated in the SCADA/EMS system in the future under a new contract. 3. Volume I paragraphs and 4.1.5: Change the reference to Energy Storage System to Supervisory Control and Data Acquisition (SCADA) System. 4. Volume I paragraph : Replace the following paragraph: (1) Cost for Minimum Annual Energy as described in the Draft Energy Storage Power Purchase Agreement for that full or partial fiscal year within the term of the contract. D. Fejeran Page 2 of 12

3 (1) Cost of the Software. 5. Volume II, paragraph 1.2.1: Delete the following last two sentences in the first paragraph: However, due to funding limitations, GWA has broken down Phase A into multiple implementations. The initial SCADA Phase A-1 will consist of a new central SCADA/EMS system connected and integrated with existing and new SCADA upgraded water and wastewater facilities. 6. Volume II, paragraph 1.2.1: Replace the following sentence of second paragraph: The GWA SCADA Master Plan provides requirements inclusive for this Bid. The GWA SCADA Master Plan is provided for Contractor information only. 7. Volume II, paragraph 1.2.2, third bullet item: Change the second sentence: The system consisted of a PLC and communication equipment at each site and one master SCADA server. This system does not interact with other systems. The system consisted of a PLC and communication equipment at each site and one master SCADA server that will be de-commissioned. 8. Volume II, paragraph 1.2.3: Replace the following: GWA has several upcoming capital improvement projects that will be upgrading 120 additional water and wastewater facilities with programmable logic controllers (or remote terminal units), communications, and field instrumentation. These new SCADA upgraded facilities need to be connected and integrated with the new SCADA/EMS system. The communication links will be provided by GPWA. Table 1-5: Number of GWA Facilities Scheduled for SCADA Upgrades Qty Facilities 77 Wastewater Pump Stations 33 Deep Wells D. Fejeran Page 3 of 12

4 5 Reservoirs 3 Water Booster Pump Stations 1 Master Meter 1 Pressure Regulating Valve 120 Total GWA has several capital improvement projects that will be upgrading 67 additional water and wastewater facilities with programmable logic controllers (or remote terminal units), communications, and field instrumentation. These new SCADA upgraded facilities shall be connected and integrated with the new SCADA/EMS system. The communication links will be provided by GPWA. Table 1-5a: Number of New GWA Facilities Scheduled for SCADA Upgrades Qty Facilities 20 Wastewater Pump Stations 33 Deep Wells 5 Reservoirs 3 Water Booster Pump Stations 5 Master Meter 1 Pressure Regulating Valve 67 Total The planned build-out of the GWA SCADA Master Plan for the remaining 331 water and wastewater facilities will be priced in the bid as an additive bid item. Should GWA choose to award the additive bid, the Contractor shall add the database points, SCADA screens and reports for 331 future facilities in the new SCADA/EMS system. The negotiations, physical connections and integrations of 331 future facilities to the SCADA/EMS system shall be performed in the future under a new contract. Table 1-5b: Number of Future GWA Facilities scheduled for SCADA Qty Facilities 58 Wastewater Pump Stations 76 Deep Wells 32 Reservoirs 33 Water Booster Pump Stations 60 Master Meter 72 Pressure Regulating Valve 331 Total 9. Volume II, section 1.3: Add a third paragraph using the following: D. Fejeran Page 4 of 12

5 The communications shall include support for existing GWA video systems to provide remote access to CCTV/security equipment. Large stations are expected to store video locally and allow limited access to files remotely. Smaller stations shall provide data management to accept images produced by local video system and store in data warehouse area associated with the affected site for retrieval by operations staff. 10. Volume II, paragraph 1.4.2: Change first two sentences of third paragraph: Data in the new SCADA/EMS system shall be geographically referenced. Contractor shall bring in the map from the ArcMap GIS into the new SCADA/EMS system to maintain one single consistent map. Data in the new SCADA/EMS system shall be geographically referenced. Contractor shall use the maps from the ArcGIS for the new SCADA/EMS system to maintain one single consistent map. 11. Volume II, paragraph 3.1.E.d: Replace the following: Delivery of a Multi-Screen Video Wall system for the GWA Systems Control Center Delivery of two (2) each wall-mounted 85 LED 2160p 4K Ultra HDTV 12. Volume II, paragraph 3.1.F.g: Replace the following: Complete and seamless integration and installation of CONTRACTOR-supplied Multi- Screen Video Wall system for the GWA Systems Control Center Complete and seamless integration and installation of two (2) each CONTRACTORsupplied wall-mounted 85 LED 2160p 4K Ultra HDTV into the operator stations with the ability to drive the HDTV image from any operator station. 13. Volume II, paragraph 3.1.F: Add the following new item (j): D. Fejeran Page 5 of 12

6 j. Complete and seamless integration with CONTRACTOR-supplied GWA wastewater operator terminal at Hagatna Wastewater Maintenance Building. 14. Volume II, Section 4: Add the following new paragraph 4.19: 4.19 GWA Graphic Screen Requirements The system shall include graphic screens for the remote sites listed in Tables 1-4, 1-5a and 1-5b. Future sites shall have capability of being added with minimal software changes to the system. Graphic screens shall provide a graphical interface between the operator and remote sites. Screens shall be developed to provide an interactive interface for all process equipment and monitored signals for each site. The general requirements are described in the subsequent paragraphs below. The screen pages shall be stored in the system server, and shall be accessible from other servers and workstations. Workstations shall have the capability to monitor and control all I/O points in the system connected to networked RTU/PLC equipment. The graphic display pages shall be able to include information from a number of distinct I/O points from various PLCs, for the formation of actual and pseudo graphics. Graphic displays shall have the ability of combining dynamic analog process variables with standard symbols on the same page. It shall be possible for any data point in the system to be displayed and controlled utilizing on-screen pages. The real-time database and number of display pages shall be reconfigurable and expandable without disruption of existing system structure. Single point trend displays shall be configurable for each analog point displayed. The control workstation shall also be capable of performing multi-point current trending and display. Single-Point display shall provide all the information and parameters particular to a single point in the system. For analog variables, a vertical bar graph of relative height may indicate the process input. Other methods of representation such as analog gauges shall be configurable. The bar graph or other representation shall have full-scale values digitally presented in engineering units. Additionally, the instantaneous value shall be digitally displayed. When a controller is displayed, the set point shall be indicated adjacent to the process bar graph. The set point and output values shall be digitally displayed. Graphical display editor software shall allow for the creation and maintenance of graphical displays for viewing process control dynamics. Graphic editor must be menu driven and contain standard geometric symbols such as lines, circles, rectangles, etc., making creation, modification and copying of graphics a simple task. Displays shall be easily created and serve as graphical representations of the plant process area, or a detailed portion of the process. These graphics shall then be dynamically connected to selected variables or operator picks. The graphic display package shall be supplied with a library of common graphic objects and symbols that can readily be incorporated into operator displays. The graphic display package shall be capable of importing graphics from the following: D. Fejeran Page 6 of 12

7 Other drawing packages such as Microstation, and AutoCAD. Microsoft Windows clipboard Objects created by other Microsoft Windows applications via OLE 2.0 or later. Status displays shall indicate the status of discrete contact pairs such as on/off or open/closed. The status text shall be selected during configuration to allow customization to the process. Sequences shall be displayable using status display pages. These shall provide the capability for Owner s personnel to incorporate text to guide the operator in making control decisions. Up to 16 discrete points shall be displayed. In the active state, text shall be displayed in red. In the inactive state, the text shall be displayed in white. Parameter displays shall indicate the value of selected points in digital form. The status may originate from anywhere in the system database and may be changed by the operator from this display. Each high-resolution trend display shall be made up of a minimum of 240 samples on a horizontal time base. Sampling frequency shall be adjustable from 1 sec. to 60 min. for a time basis of 40 minutes to 1 month, full scale. Resolution of the vertical scale shall be 0.5 percent of range or better. Display range shall be user selectable for each point. A cursor shall be provided to assist in reading values of points along with the time base. Operator control of the cursor shall be accomplished from the keyboard or with the mouse. The identification of points in trend, current values, value, time and data represented by the position of the cursor, engineering units measurement, range and type of value recorded shall be clearly indicated in digital form on each display. The system shall be capable of collecting and storing historical data in files on the Data Historian system hard disk as described elsewhere in this bid. The Data Historian Server and any Workstation shall be capable of displaying any of the historical points. All alarms detected in the instruments communicating with the workstations shall be annunciated both visually on the operator s CRT display and audibly via the operator s computer sound system. Upon detection, the tag name of the point in alarm shall turn red and begin blinking. Report editor shall be provided that supports the development of a variety of formats to present system data (digital or analog). The report editor shall allow the selection of data points, range of data and allow calculations for Max/Min/Avg and similar values. Some examples (not specific requirements but supporting information related to the type of graphic screens being described) of graphic screens are provided for reference: Figure 4-2: Graphic Screen Example 1 D. Fejeran Page 7 of 12

8 Figure 4-2: Graphic Screen Example 2 D. Fejeran Page 8 of 12

9 15. Appendix A Bid Checklist: Replace the following third line item. Amended Document Receipt Checklist form is attached. Volume III: Energy Storage Contract (Draft) Volume III: Supervisory Control and Data Acquisition (SCADA) System Contract (Draft) 16. Appendix P: Replace the system sizing for the following MMI/Consoles: System Sizing Initial Sizing Ultimate Sizing GPA GWA GPA GWA No. of dispatcher consoles-local LCD No. of dispatcher consoles-local LCD No. of dispatcher consoles-local *21 LCD No. of dispatcher consoles-local LCD No. of Remote PC Consoles 8 16 (Software only) No. of Maintenance Consoles LCD No. of Engineering Consoles LCD No. of Projection Mapboard Drivers (Single screen) No. of Map-board Status Points 600 To be determined 600 To be determined No. of Digital Display (i.e. Time, Frequency, Voltage, Windspeed) System Sizing Initial Sizing Ultimate Sizing GPA GWA GPA GWA No. of dispatcher consoles-local LCD No. of dispatcher consoles-local 3-27 LCD D. Fejeran Page 9 of 12

10 No. of dispatcher consoles-local LCD No. of dispatcher consoles-local LCD No. of Remote PC Consoles LCD No. of Remote PC Consoles (Software only) No. of Maintenance Consoles LCD No. of Maintenance Consoles LCD No. of Engineering Consoles LCD No. of Projection Mapboard Drivers (Single screen) No. of Map-board Status Points 600 To be determined 600 To be determined No. of Digital Display (i.e. Time, Frequency, Voltage, Windspeed) Appendix P: Replace the system sizing for the following GWA Network Model: System Sizing Initial Sizing Ultimate Sizing GPA GWA GPA GWA GWA Network Model Water System: No. of Deep Wells No. of Water Treatment Plants 0 6 No. of Springs 0 5 No. of Water Booster Pump Stations 3 40 No. of Reservoirs 7 39 No. of System Meters 1 65 No. of Pressure Regulating Valves 1 73 No. of Water Lines No. of Areas/Zones Wastewater System: No. of Wastewater Treatment Plants 1 2 No. of Wastewater Sewer Pump Stations No. of Wastewater Lines No. of Areas/Zones D. Fejeran Page 10 of 12

11 System Sizing Initial Sizing Ultimate Sizing GPA GWA GPA GWA GWA Network Model Water System: No. of Deep Wells No. of Water Treatment Plants 0 1 No. of Springs 0 2 No. of Water Booster Pump Stations 3 36 No. of Reservoirs 7 39 No. of System Meters 5 65 No. of Pressure Regulating Valves 1 73 No. of Water Lines No. of Areas/Zones Wastewater System: No. of Wastewater Treatment Plants 1 6 No. of Wastewater Sewer Pump Stations No. of Wastewater Lines No. of Areas/Zones 18. Appendix S: Replace the following GWA s Workstations Monitor Quantity: GWA s WORKSTATIONS MONITOR QUANTITY: 15 Each Station Position 27" Monitors 1 System Dispatcher 3 2 System Dispatcher 3 3 Trouble Dispatcher 2 4 Trouble Dispatcher 2 5 Auxiliary Desk (Dispatcher) 2 6 Dispatcher Training Simulator 3 7 Systems Control Center Supervisor 3 8 IT Manager 3 9 IT Network Supervisor 3 10 IT Lab 3 11 Assistant General Manager, Operations, Water D. Fejeran Page 11 of 12 2

12

13

14

Table 1-4: Number of GWA Facilities with standalone systems

Table 1-4: Number of GWA Facilities with standalone systems standalone systems. For this project, the Contractor shall integrate the 13 facilities and the Wastewater Treatment Plant with the new SCADA/EMS system. For the Water Treatment Plant (WTP), the Contractor

More information

REPORT TO COUNCIL City of Sacramento

REPORT TO COUNCIL City of Sacramento REPORT TO COUNCIL City of Sacramento 915 I Street, Sacramento, CA 95814-2604 www. CityofSacramento.org 14 Consent November 10, 2009 Honorable Mayor and Members of the City Council Agreement: Supervisory

More information

By Raymond Grosch Senior System Analyst IntelliSys Inc.

By Raymond Grosch Senior System Analyst IntelliSys Inc. IntelliSys Inc. White Paper 09 W. Washington Chicago, IL 60606 800.7.9977 www.intellisyssoftware.com Keywords: SystemVIEW, process visualization, SCADA (Supervisory Control And Data Acquisition), HMI (Human

More information

SECTION SCADA SYSTEM APPLICATIONS PROGRAMMING PART 1 - GENERAL 1.01 SCOPE OF WORK

SECTION SCADA SYSTEM APPLICATIONS PROGRAMMING PART 1 - GENERAL 1.01 SCOPE OF WORK SECTON 16925 SCADA SYSTEM APPLCATONS PROGRAMMNG PART 1 - GENERAL 1.01 SCOPE OF WORK A. Programming and configuration of the SCADA system (Server and Workstations) is by Owner Representative, herein defined

More information

CITY of NOVI CITY COUNCIL

CITY of NOVI CITY COUNCIL CITY of NOVI CITY COUNCIL Agenda Item D May 22,2017 SUBJECT: Approval to award SCADA implementation services to ICS Integration Services LLC for work related to the completion of the City's SCADA system,

More information

INVITATION FOR BIDS For RO PLANT #2 PLC SYSTEMS UPGRADE (CIP# WTR1702)

INVITATION FOR BIDS For RO PLANT #2 PLC SYSTEMS UPGRADE (CIP# WTR1702) INVITATION FOR BIDS For RO PLANT #2 PLC SYSTEMS UPGRADE (CIP# WTR1702) BID SUBMITTAL DATE, TIME, & LOCATION: EMAIL QUESTIONS TO: December 8, 2017 @ 2:00 PM Mount Pleasant Waterworks Operations Center 1619

More information

Advances in Telemetry. Finding out what is really going on in your system

Advances in Telemetry. Finding out what is really going on in your system Advances in Telemetry { Finding out what is really going on in your system Dr. David Mundie President of High Tide Technologies Involved in telemetry design for over 30 years Space, Air and Ground Telemetry

More information

9611 SE 36th Street Mercer Island, WA Request for Proposal (RFP #17-11) City of Mercer Island Contracted Services for:

9611 SE 36th Street Mercer Island, WA Request for Proposal (RFP #17-11) City of Mercer Island Contracted Services for: 9611 SE 36th Street Mercer Island, WA 98040 Request for Proposal (RFP #17-11) City of Mercer Island Contracted Services for: WATER AND SEWER CONTROL SYSTEM - HARDWARE/SOFTWARE Release Date: November 21,

More information

Minimum Support Needed for a Reliable SCADA System

Minimum Support Needed for a Reliable SCADA System Minimum Support Needed for a Reliable SCADA System Speaker Bio Jeff Miller, PE, ISI ENV SP Dewberry Automation Manager MEP Service Line Raleigh, NC 22 years experience in Electrical / Instrumentation &

More information

AGENDA ITEM EXECUTIVE SUMMARY

AGENDA ITEM EXECUTIVE SUMMARY 202 AGENDA ITEM EXECUTIVE SUMMARY Agenda Item: Presenter & Title: Wastewater Treatment Plant SCADA System and Fiber Optic Communication System Upgrades Richard Babica, Director of Public Works Date: May

More information

. SECTION SUPERVISORY CONTROL AND DATA ACQUISITION SYSTEM

. SECTION SUPERVISORY CONTROL AND DATA ACQUISITION SYSTEM . SECTION 13380 - SUPERVISORY CONTROL AND DATA ACQUISITION SYSTEM PART 1 - GENERAL 1.01 WORK OF THIS SECTION A. The CONTRACTOR shall furnish, install, configure, program, test and put into operation the

More information

PIMA COUNTY REGIONAL WASTEWATER RECLAMATION DEPARTMENT SCADA STANDARDIZATION PROJECT TABLE OF CONTENTS

PIMA COUNTY REGIONAL WASTEWATER RECLAMATION DEPARTMENT SCADA STANDARDIZATION PROJECT TABLE OF CONTENTS PIMA COUNTY REGIONAL WASTEWATER RECLAMATION DEPARTMENT SCADA STANDARDIZATION PROJECT TABLE OF CONTENTS Section Page DIVISION 13 - SPECIAL CONSTRUCTION 13401 SCADA System, General Requirements... 13401-1

More information

SCADA Systems for Water and Wastewater Applications

SCADA Systems for Water and Wastewater Applications SCADA Systems for Water and Wastewater Applications TMACOG Water/Wastewater Training Event, May 9 th 2018 Presenter Alex Gyurgyak P.E. Presented by Dmytryka Jacobs Engineers, Inc. Toledo, Ohio SCADA Systems

More information

SCADA Solutions for Water and Wastewater Treatment Plants

SCADA Solutions for Water and Wastewater Treatment Plants SCADA Solutions for Water and Wastewater Treatment Plants Features Centralized control Increased reliability Improved management of treatment processes Reduced costs Preserved equipment investments Flexible

More information

Minutes - Standing Policy Committee on Finance - April 9, 2015 REPORTS

Minutes - Standing Policy Committee on Finance - April 9, 2015 REPORTS Minutes - Standing Policy Committee on Finance - April 9, 2015 REPORTS Item No. 4 Water Supervisory Control and Data Acquisition (SCADA) Upgrade Financial Status Report No. 1 for the Period from November

More information

YOU RE FEELING THE PRESSURE. MORE CONTROL. LESS STRESS.

YOU RE FEELING THE PRESSURE. MORE CONTROL. LESS STRESS. YOU RE FEELING THE PRESSURE. From water pressure to financial pressure, communities today face a growing number of challenges in providing water and wastewater services, including capital and operating

More information

Appendix B. TechKnowsion PLC and SCADA Programming Proposal

Appendix B. TechKnowsion PLC and SCADA Programming Proposal Appendix B TechKnowsion PLC and SCADA Programming Proposal THIS PAGE LEFT INTENTIONALLY BLANK TechKnowsion, Inc. 3305 Vincent Road Pleasant Hill, CA 94523 925.939.8324 Voice 925.280.8324 Fax www.techknowsion.com

More information

SCADA.What s out there?

SCADA.What s out there? SCADA.What s out there? Ed Dunn Precision Systems Our Goal Today To prepare you with the knowledge / questions necessary to make the correct decision as to what type of system best suits your needs 1 SCADA

More information

Evaluation of Jackson and Saylor Sanitary Sewer Lift Station During July 23-24, 2010 Storm Event. Presented by:

Evaluation of Jackson and Saylor Sanitary Sewer Lift Station During July 23-24, 2010 Storm Event. Presented by: City of Elmhurst Evaluation of Jackson and Saylor Sanitary Sewer Lift Station During July 23-24, 2010 Storm Event Christopher B. Burke Engineering, Ltd. Presented by: Christopher B. Burke, PhD, PE, D.WRE,

More information

INDUSTRIAL CONTROL SYSTEMS & COMPUTER PROCESS CONTROL

INDUSTRIAL CONTROL SYSTEMS & COMPUTER PROCESS CONTROL 1 INDUSTRIAL CONTROL SYSTEMS & COMPUTER PROCESS CONTROL INDUSTRIAL CONTROL - DEFINED The automatic regulation of unit operations and their associated equipment as well as the integration and coordination

More information

Authorized Systems Integrator. Automation Systems Telemetry & SCADA

Authorized Systems Integrator. Automation Systems Telemetry & SCADA Authorized Systems Integrator Automation Systems Telemetry & SCADA Horizons Engineering Switchgear Manufacturing Co. plc. is an Authorized System Integrator, Automation Partner for Schneider Electric Automation.

More information

SCADA Upgrades to Otay Water Treatment Plant

SCADA Upgrades to Otay Water Treatment Plant SCADA Upgrades to Otay Water Treatment Plant Standards Certification Education & Training Publishing Conferences & Exhibits Speaker: Dr. Noune Garounts 2012 ISA Water & Wastewater and Automatic Controls

More information

Specification Voltage Limiting Device

Specification Voltage Limiting Device Engineering Specification Electrical Networks L1-CHE-SPE-152 Specification Voltage Limiting Device Version: 1 Issued: 20 th April 2018 Owner: Chief Engineer Approved By: Andrew Russack Head of Engineering,

More information

Project Life Cycle Support (SCADA)

Project Life Cycle Support (SCADA) Project Life Cycle Support (SCADA) Texas Association of Clean Water Agencies Garland, TX March 26, 2010 Yehuda Morag CH2M HILL, Austin TX WBG030410171936AUS Agenda Introduction to SCADA Utility Managers

More information

Addendum # 1 Cumberland County, PA CPE RFP Clarifications January

Addendum # 1 Cumberland County, PA CPE RFP Clarifications January . Request for Submittal Extension ANSWER: All date references listed in the document for submittal deadline shall now be FRIDAY FEBRUARY, 20 at 2:00 PM. All other requirements remain the same. 2. Are we

More information

DECEMBER 11, PLC-Based Waste Water Lift Station with Demo Box. by Lance McParlan Advisor & Instructor: Paul Lin. Outline

DECEMBER 11, PLC-Based Waste Water Lift Station with Demo Box. by Lance McParlan Advisor & Instructor: Paul Lin. Outline DECEMBER 11, 2015 PLC-Based Waste Water Lift Station with Demo Box by Lance McParlan Advisor & Instructor: Paul Lin Outline This presentation will cover: What a Lift Station is Why they are being upgraded

More information

18.0 CONTROLS PLATFORM AND AUTOMATION

18.0 CONTROLS PLATFORM AND AUTOMATION SEWPCC Upgrading/Expansion Conceptual Design Report SECTION 18 - Table of Contents 18.0 CONTROLS PLATFORM AND AUTOMATION...18.1 18.1 INTRODUCTION...18.1 18.2 SYSTEM INFORMATION...18.1 18.3 FUNCTIONAL REQUIREMENTS

More information

MOSCAD WIRELESS MONITORING AND CONTROL SOLUTIONS FOR THE WATER/WASTEWATER INDUSTRY

MOSCAD WIRELESS MONITORING AND CONTROL SOLUTIONS FOR THE WATER/WASTEWATER INDUSTRY MOSCAD WIRELESS MONITORING AND CONTROL SOLUTIONS FOR THE WATER/WASTEWATER INDUSTRY MOSCAD is a product born of Motorola s 60-year commitment to cutting edge technology. This quest for communications of

More information

PRICOM Power Communication and Control Systems

PRICOM Power Communication and Control Systems ABB Power T&D Company Inc. Power Automation & Protection Division Coral Springs, FL Allentown, PA Descriptive Bulletin Page 1 Effective: August 1998 New Information PRICOM Power Communication and Control

More information

ELECTRICAL, INSTRUMENTATION & CONTROL SYSTEMS

ELECTRICAL, INSTRUMENTATION & CONTROL SYSTEMS ELECTRICAL, INSTRUMENTATION & CONTROL SYSTEMS Presentation by: RANA NASIR ALI General Manager, Power Plants Projects, at PITCO November 02, 2017 ELECTRICAL PLANT CONCEPT The electrical equipment, depending

More information

Real-time Power System Operation. Energy Management Systems. Introduction

Real-time Power System Operation. Energy Management Systems. Introduction 1 Real-time Power System Operation Energy Management Systems Introduction The time frame for Power Systems Operation varies from a few seconds to a week. To assist with the operation of the system, modern

More information

APPLICATIONS FEATURES UL LISTINGS YOUR PRIME CHOICE FOR MUNICIPAL WATER CONTROL SOLUTIONS

APPLICATIONS FEATURES UL LISTINGS YOUR PRIME CHOICE FOR MUNICIPAL WATER CONTROL SOLUTIONS YOUR PRIME CHOICE FOR MUNICIPAL WATER CONTROL SOLUTIONS With thousands of panels installed across North America, our team, backed by hundreds of years of experience, designs and builds complete control

More information

Established Leaders in Actuation Technology. In-Vision PC based supervisory control. Publication S210E issue 04/03

Established Leaders in Actuation Technology. In-Vision PC based supervisory control. Publication S210E issue 04/03 Established Leaders in Actuation Technology In-Vision PC based supervisory control Publication S210E issue 04/03 2 ROTORK IN-VISION In-Vision PC based supervisory control In-Vision is a user friendly PC

More information

SCADA Software. 3.1 SCADA communication architectures SCADA system

SCADA Software. 3.1 SCADA communication architectures SCADA system 3 SCADA Software 3.1 SCADA communication architectures 3.1.1 SCADA system A supervisory control and data acquisition (SCADA) system means a system consisting of a number of remote terminal units (RTUs)

More information

Section 3.0 Financial Requirements

Section 3.0 Financial Requirements Section 3.0 Financial Requirements Section 3.0 Financial Requirements 3.1 Impact Fees 3.1.1 What are Impact Fees 3.1.2 How are Impact Fees Calculated 3.1.3 Assignment of Impact Fees 3.2 Summary of Required

More information

Westin Good Faith Effort Outreach Letter

Westin Good Faith Effort Outreach Letter Westin Good Faith Effort Outreach Letter To: Outreach Agencies for the City of Los Angeles Department of Water and Power Subject: Requests for Expressions of Interest Request for Proposals No. RFP258-09

More information

Recorders for all applications

Recorders for all applications Recorders for all applications Within the COMMANDER family are specifically-designed control solution variants for industries such as water and waste water, food, chemical & pharmaceutical and heat treatment.

More information

Accord Builder. User Guide

Accord Builder. User Guide User Guide Document: V 3.6 User Guide R01 V3.6 User Guide R01 Page 1 of 110 Table of Contents 1 Introduction... 7 2 General Summary and Definitions... 8 2.1 Accord Platform and Plant... 8 2.2 PLC Control

More information

What is SCADA? What is Telemetry? What is Data Acquisition? Differences between SCADA and DCS? Components of SCADA. Field Instrumentation

What is SCADA? What is Telemetry? What is Data Acquisition? Differences between SCADA and DCS? Components of SCADA. Field Instrumentation SCADA Primer This document discusses the basics of SCADA systems. It serves as introduction for those who are not familiar with it, and as a reviewer for those who are already knowledgeable about the SCADA

More information

Linus L. Smith, GIS Supervisor, Engineering Public Works Department, City of Winfield, Kansas

Linus L. Smith, GIS Supervisor, Engineering Public Works Department, City of Winfield, Kansas Challenges in Developing a City GIS Wastewater Geo Database System Linus L. Smith, GIS Supervisor, Engineering Public Works Department, City of Winfield, Kansas OVERVIEW The City of Winfield Kansas recognized

More information

SCADA MANUAL Siemens WinCC Advanced Runtime

SCADA MANUAL Siemens WinCC Advanced Runtime SCADA MANUAL Siemens WinCC Advanced Runtime Date: Signed: Concept Production As Built Revision Principal Customer Place of installation Product Principal

More information

Micro-PWC Personal Work Center PW6000

Micro-PWC Personal Work Center PW6000 Micro-PWC Personal Work Center PW6000 Engineering, Operation and Information Workstation software Dynamic graphic displays with network-wide database access Real-time, historical and archive trend displays

More information

FIGURE 1. Five Logical Levels of a SCADA System

FIGURE 1. Five Logical Levels of a SCADA System SCADA AND TELEMETRY IN NATURAL GAS OPERATIONS Russel W. Treat EnerSys Corporation Introduction SCADA systems provide are combinations of field devices, communications infrastructure and software integrated

More information

DISTRICT OF COLUMBIA WATER AND SEWER AUTHORITY ATTACHMENT A A-1: BACKGROUND AND CONTRACTOR QUALIFICATIONS A-2: SCOPE OF WORK

DISTRICT OF COLUMBIA WATER AND SEWER AUTHORITY ATTACHMENT A A-1: BACKGROUND AND CONTRACTOR QUALIFICATIONS A-2: SCOPE OF WORK DISTRICT OF COLUMBIA WATER AND SEWER AUTHORITY ATTACHMENT A A-1: BACKGROUND AND CONTRACTOR QUALIFICATIONS A-2: SCOPE OF WORK GOODS AND SERVICES CONTRACTS Page 1 of 5 RFP 16-PR-DEM-33 Comprehensive All-Hazards

More information

CNC Tube Bending Machine & its Software (On Turn key basis) SL. NO. DESCRIPTION OF REQUIREMENT REQUIRED 1 Scope

CNC Tube Bending Machine & its Software (On Turn key basis) SL. NO. DESCRIPTION OF REQUIREMENT REQUIRED 1 Scope CNC Tube Bending Machine & its Software (On Turn key basis) Code No. PURPOSE: CNC tube bending machine for bending of MS/Al/SS tubes. SPECIFICATIONS: Qty. 01 Set SL. NO. DESCRIPTION OF REQUIREMENT REQUIRED

More information

Distributed Control System Design Standards

Distributed Control System Design Standards Distributed Control System Design Standards I. Background and Overview A. The City s Program Standards and Procedures (PSP) are intended to be used in conjunction with the data contained in related standards

More information

WHAT are SCADA and I&C?

WHAT are SCADA and I&C? What is SCADA? WHAT are SCADA and &C? SCADA is a term for a type of system. The acronym stands for Supervisory Control And Data Acquisition &C describes a field or specialty. The acronym stands for nstrumentation

More information

Committee on Water and Task Force on Innovation

Committee on Water and Task Force on Innovation Committee on Water and Task Force on Innovation Using IIoT to Drive Business Insights John Kuchmek American Water Krishna Kumar App Orchid WHO WE ARE We are the largest and most geographically diverse

More information

DESCRIPTION OF OPERATION CONTROL CENTER (OCC) INSTALLED AT DA NHIM HAM THUAN DA MI HYDROPOWER COMPANY

DESCRIPTION OF OPERATION CONTROL CENTER (OCC) INSTALLED AT DA NHIM HAM THUAN DA MI HYDROPOWER COMPANY Applied Technical Systems Company Ltd. DESCRIPTION OF OPERATION CONTROL CENTER (OCC) INSTALLED AT DA NHIM HAM THUAN DA MI HYDROPOWER COMPANY This document contains informations of ATS company. These informations

More information

Request for Proposals. Information Technology Consultant and Network & Information Technology Support Services

Request for Proposals. Information Technology Consultant and Network & Information Technology Support Services Request for Proposals Information Technology Consultant and Network & Information Technology Support Services July 18, 2018 General Description The City of Greenville is looking to select a qualified firm

More information

Water Flow Identification and Theft Control of Automated Urban Water Supply

Water Flow Identification and Theft Control of Automated Urban Water Supply Water Flow Identification and Theft Control of Automated Urban Water Supply K. SREENIVASA RAO 1 & K. PAVAN KUMAR 2 1 Department of Electronics and Communication Engineering, KSRM College of Engineering,

More information

MEETING THE CHALLENGES OF UPGRADING THE PLANT CONTROL SYSTEM YIELDS MAJOR OPERATIONS BENEFITS

MEETING THE CHALLENGES OF UPGRADING THE PLANT CONTROL SYSTEM YIELDS MAJOR OPERATIONS BENEFITS MEETING THE CHALLENGES OF UPGRADING THE PLANT CONTROL SYSTEM YIELDS MAJOR OPERATIONS BENEFITS Mike Richardson Water Resources Manager, Cape Fear Public Utility Authority Nan Johnson VP Municipal Business,

More information

MESP TECHNICAL SPECIFICATION FOR A RECTIFIER UNIT CONTROL & PROTECTION SYSTEM FOR USE IN THE 1500V DC TRACTION SYSTEM

MESP TECHNICAL SPECIFICATION FOR A RECTIFIER UNIT CONTROL & PROTECTION SYSTEM FOR USE IN THE 1500V DC TRACTION SYSTEM Engineering Specification Electrical Networks TECHNICAL SPECIFICATION FOR A RECTIFIER UNIT CONTROL & PROTECTION SYSTEM FOR USE IN THE 1500V Version: 1 Issued: March 2014 Owner: Electrical Networks Asset

More information

Electrical & Controls. September 28, 2017

Electrical & Controls. September 28, 2017 Electrical & Controls September 28, 2017 What is a PLC? Programmable Logic Controller Definition Industrial computer based control system that continuously monitors the state of input devices and makes

More information

APPROVE PROCUREMENT PROCESS FOR EQUIPMENT AND INSTALLATION

APPROVE PROCUREMENT PROCESS FOR EQUIPMENT AND INSTALLATION etro Metropolitan Transportation Authority One Gateway Plaza Los Angeles, CA 90012-2952 213. 922. 20( met,". OPERATIONS COMMITTEE JANUARY 20, 2005 SUBJECT: ACTION~ METRO RED LINE SEGMENT-! REMOTE TERMINAL

More information

Web Page. Advertisement for SCADA System Manager post

Web Page. Advertisement for SCADA System Manager post Web Page Advertisement for SCADA System Manager post SCADA System Manager Closing Date: 9 June 2017 Job Category: Technical Job Location: Sophia, Georgetown Job Schedules: Employed --- Contents ---------------------------------------------------------------------------------------------------------------------

More information

APPENDIX 4 to LGIP INTERCONNECTION FACILITIES STUDY AGREEMENT

APPENDIX 4 to LGIP INTERCONNECTION FACILITIES STUDY AGREEMENT APPENDIX 4 to LGIP INTERCONNECTION FACILITIES STUDY AGREEMENT THIS AGREEMENT is made and entered into this day of, 20 by and between [Customer Name (Project Name, QXXXX)], a [Type of company] organized

More information

SCADA System Specification. Vantage Pipeline Project # May 2013

SCADA System Specification. Vantage Pipeline Project # May 2013 SCADA System Specification Vantage Pipeline Project #201011 May 2013 Revision 0 Issued for Approval May 24, 2013 TABLE OF CONTENTS REVISION HISTORY:...2 1 PROJECT OVERVIEW...3 2 SCOPE AND PURPOSE...4 3

More information

PROGRESS IN DEVELOPING A WEB-BASED MANAGEMENT SYSTEM FOR IRRIGATION DISTRICTS

PROGRESS IN DEVELOPING A WEB-BASED MANAGEMENT SYSTEM FOR IRRIGATION DISTRICTS PROGRESS IN DEVELOPING A WEB-BASED MANAGEMENT SYSTEM FOR IRRIGATION DISTRICTS USCID Water Management Conference Irrigated Agriculture Responds to Water Use Challenges Strategies for Success Austin, Texas

More information

Service Plan for Infrastructure Engineering

Service Plan for Infrastructure Engineering Service Plan for Infrastructure 2016-2019 Capital Regional District Date submitted: Revised: August 14, 2017 Table of Contents 1 Overview... 1 1.1 Division & Service Summary... 1 1.2 Organization Chart...

More information

3/2/ /2/ :05 AM EET 415/4 Power System Operation 1 3/2/ :05 AM EET 415 2

3/2/ /2/ :05 AM EET 415/4 Power System Operation 1 3/2/ :05 AM EET 415 2 Communication in Power System II 3/2/2009 11:05 AM EET 415/4 Power System Operation 1 Communication In Power System II CONTENTS SCADA Definition SCADA Evolution Basic SCADA System Architecture Typical

More information

Compact data logger offering best-in-class noise resistance and communication function

Compact data logger offering best-in-class noise resistance and communication function T M Portable Data Station XL100 Series Compact data logger offering best-in-class noise resistance and communication function A world s first in measuring instruments! To obtain IPv6 Ready Logo Phase-1

More information

Project Profiles. Refinery & Chemical Systems

Project Profiles. Refinery & Chemical Systems Project Profiles Refinery & Chemical s Able-Baker Automation, Inc. P.O. Box 6368 Moraga, CA 94570 (USA) 1-510-601-9396 Fax: 1-510-601-9398 1-877-444-ABLE (2253) Home Page: www.able-baker.com Titanium Dioxide

More information

UW Purchase Specification Section Central Cooling Water Meter Page 1 of 6

UW Purchase Specification Section Central Cooling Water Meter Page 1 of 6 Page 1 of 6 PART 1 GENERAL 1.01 DESCRIPTION A. Purpose 1. This section covers central cooling water meters for use in the Owner's central cooling water systems. 1.02 QUALIFICATIONS A. Approved manufacturers

More information

PLC 23 DUAL MEDIA FILTERS 5 AND 6 SCADA SYSTEM OPERATION MANUAL. Revision 1.0 April 18, 2006

PLC 23 DUAL MEDIA FILTERS 5 AND 6 SCADA SYSTEM OPERATION MANUAL. Revision 1.0 April 18, 2006 PLC 23 DUAL MEDIA FILTERS 5 AND 6 SCADA SYSTEM OPERATION MANUAL Revision 1.0 April 18, 2006 PLC 23 DUAL MEDIA FILTERS 5 AND 6 SCADA SYSTEM OPERATION MANUAL Revision 1.0 April 18, 2006 Table of Contents

More information

Getting the Most from Your SCADA Data

Getting the Most from Your SCADA Data Getting the Most from Your SCADA Data Standards Certification Education & Training Publishing Conferences & Exhibits Speaker: Emile Richard 2015 ISA Water / Wastewater and Automatic Controls Symposium

More information

Commander circular chart recorders The tried and tested solution for process recording

Commander circular chart recorders The tried and tested solution for process recording The tried and tested solution for process recording ABB s Commander circular chart recorders provide a tried and tested solution for a host of industries such as water and waste water, food, chemical and

More information

CAISO RIG Acceptance Test Procedure

CAISO RIG Acceptance Test Procedure CAISO RIG Acceptance Test Procedure TABLE OF CONTENTS 1.0 PURPOSE... 3 2.0 INTRODUCTION... 3 3.0 TEST PROCEDURE... 8 Market Services/ EDAS CAISO Public Revision History 1.0 PURPOSE The procedure is intended

More information

Ovation Process Historian

Ovation Process Historian Ovation Process Historian Features Designed to meet the needs of precision, performance, scalability and historical data management for the Ovation control system Collects historical data of Ovation process

More information

Designing a new IEC substation architecture

Designing a new IEC substation architecture Designing a new IEC 61850 substation architecture Gerrit Dogger Senior Product and Application Specialist Cooper Power Systems gerrit.dogger@cybectec.com Garry Tennese Station Integration Specialist Manitoba

More information

HARDWARE OF SUPERVISORY CONTROL & DATA ACQUISITION SYSTEM

HARDWARE OF SUPERVISORY CONTROL & DATA ACQUISITION SYSTEM Chapter 3 HARDWARE OF SUPERVISORY CONTROL & DATA ACQUISITION SYSTEM Dr. H.K. VERMA Distinguished Professor Department of Electrical and Electronics Engineering School of Engineering and Technology SHARDA

More information

ACONIS Advanced Control & Integration System

ACONIS Advanced Control & Integration System We Build a Better Future! Advanced Control & Integration System Hyundai ACONIS series offers the operator full integration of all control & automation function in combination with several systems such

More information

Municipality Moves SCADA System from Desktop Computers to Terminal Services

Municipality Moves SCADA System from Desktop Computers to Terminal Services Municipality Moves SCADA System from Desktop Computers to Terminal Services Standards Certification Education & Training Publishing Conferences & Exhibits Speakers: Bosko Bob Loncar 2014 ISA Water / Wastewater

More information

Superview INSTRUCTIONS. Version 2.0x

Superview INSTRUCTIONS. Version 2.0x INSTRUCTIONS Version 2.0x INDEX INDEX... 1 INTRODUCTION... 2 INSTALLING SUPERVIEW... 3 SYSTEM REQUIREMENTS... 3 INSTALLATION PROCEDURES... 3 FIRST STEPS... 4 CREATING A SIMPLE APPLICATION... 4 Start...

More information

Water Treatment >>> Core Business B

Water Treatment >>> Core Business B Water Treatment >>> Core Business B Siu Ho Wan Backup Telemetry System Davenham Engineering Limited Use Allen Bradley PLC 5 w/controlnet capability (~300 I/O) Provide the newest available communication

More information

CONTRACT DOCUMENTS. for the CIGAR LAKE: RECLAIMED WATER DISTRIBUTION PUMP STATION (ITB - U ) PREPARED BY

CONTRACT DOCUMENTS. for the CIGAR LAKE: RECLAIMED WATER DISTRIBUTION PUMP STATION (ITB - U ) PREPARED BY Addendum No. 2 December 19, 2006 CONTRACT DOCUMENTS for the CIGAR LAKE: RECLAIMED WATER STRIBUTION PUMP STATION (ITB - U - 07-04) PREPARED BY CPH ENGINEERS, INC. P.O. BOX 2808 SANFORD, FL 32772-2808 PHONE:

More information

PLC 5 BIOTOWERS SCADA SYSTEM OPERATION MANUAL. Revision 1.0 May 15, 2006

PLC 5 BIOTOWERS SCADA SYSTEM OPERATION MANUAL. Revision 1.0 May 15, 2006 PLC 5 BIOTOWERS SCADA SYSTEM OPERATION MANUAL Revision 1.0 May 15, 2006 PLC 5 BIOTOWERS SCADA SYSTEM OPERATION MANUAL Revision 1.0 May 15, 2006 Table of Contents 1 Introduction... 4 2 Revision History...

More information

SCADA Solutions Since 1981 DATA FLOW SYSTEMS

SCADA Solutions Since 1981 DATA FLOW SYSTEMS SCADA Solutions Since 1981 DATA FLOW SYSTEMS SCADA System Overview SCADA SYSTEM SECURITY The HT3 SCADA Software program is password protected to prevent unauthorized access to the system. All passwords

More information

ELECTRICAL NETWORK SUPERVISOR STATUS REPORT

ELECTRICAL NETWORK SUPERVISOR STATUS REPORT EUROPEAN ORGANIZATION FOR NUCLEAR RESEARCH ORGANISATION EUROPÉENNE POUR LA RECHERCHE NUCLÉAIRE CERN - ST Division CERN-ST-2001-018 30 January 2001 ELECTRICAL NETWORK SUPERVISOR STATUS REPORT S. Poulsen

More information

Massachusetts Water Resources Authority FY17 Proposed Capital Improvement Budget

Massachusetts Water Resources Authority FY17 Proposed Capital Improvement Budget Massachusetts Water Resources Authority FY17 Proposed Capital Improvement Budget December 16, 2015 FY17 Proposed CIP Fix it First MWRA continues to focus on Asset Protection and Long Term Redundancy initiatives;

More information

EDS SCADA NUMBERING SYSTEM

EDS SCADA NUMBERING SYSTEM Document Number: EDS 05-9007 Network(s): Summary: EPN, LPN, SPN ENGINEERING DESIGN STANDARD EDS 05-9007 SCADA NUMBERING SYSTEM This standard describes the system for numbering SCADA wiring within switchgear

More information

Engineering SCADA (Introduction) Dr. Sasidharan Sreedharan

Engineering SCADA (Introduction) Dr. Sasidharan Sreedharan Engineering SCADA (Introduction) Dr. Sasidharan Sreedharan www.sasidharan.webs.com Contents What is a SCADA System Simple SCADA System lay out and working Components of a SCADA System Levels of SCADA -

More information

VILLAGE OF DOWNERS GROVE REPORT FOR THE VILLAGE COUNCIL MEETING OCTOBER 5, 2010 AGENDA

VILLAGE OF DOWNERS GROVE REPORT FOR THE VILLAGE COUNCIL MEETING OCTOBER 5, 2010 AGENDA VILLAGE OF DOWNERS GROVE REPORT FOR THE VILLAGE COUNCIL MEETING OCTOBER 5, 2010 AGENDA ITEM RES 00-04263 SUBJECT: TYPE: SUBMITTED BY: SCADA System Improvements Resolution Ordinance Motion Discussion Only

More information

Learners can have choices to obtain qualification from any of the following: Advanced Diploma in Instrumentation Maintenance Technician - IVQ: Level 3

Learners can have choices to obtain qualification from any of the following: Advanced Diploma in Instrumentation Maintenance Technician - IVQ: Level 3 1 Head Office: SIIT BuildingMain Road, Thalayolaparambu, Kottayam Dist., Kerala, India, PIN: 686 605 : 0489 236669, : +91 99 61 73 66 55, 99 61 97 66 33 e-mail : siit@siitonline.com, www.siitonline.com

More information

PISMO BEACH COUNCIL AGENDA REPORT

PISMO BEACH COUNCIL AGENDA REPORT PISMO BEACH COUNCIL AGENDA REPORT SUBJECT/TITLE: REVIEW OF INFORMATION TECHNOLOGY (IT) STATUS AND IT STRATEGIC PLAN IMPLEMENTATION UPDATE. RECOMMENDATION: 1. Receive the IT Status and Implementation Update.

More information

Waste Water Collection System Wireless Monitoring Solutions

Waste Water Collection System Wireless Monitoring Solutions Waste Water Collection System Wireless Monitoring Solutions SSO Lift Station Rainfall Flow Meters Ground Water Flap Gate Pressure Relief Valve CSO Flow with A/V Sensor Waste Water Collection Monitoring

More information

SCADA. Features and Benefits for Small to Medium Sized Communities. Presented by: Rick Alvarez

SCADA. Features and Benefits for Small to Medium Sized Communities. Presented by: Rick Alvarez SCADA Features and Benefits for Small to Medium Sized Communities Presented by: Rick Alvarez What is SCADA? Why do you need it? What types of SCADA are available? What communication options are available?

More information

PROJECT TELEMETRY SYSTEM UPGRADES, PHASE 3 IOWA GREAT LAKES SANITARY DISTRICT MILFORD, IOWA. ADDENDUM NO. 2 August 15, 2017

PROJECT TELEMETRY SYSTEM UPGRADES, PHASE 3 IOWA GREAT LAKES SANITARY DISTRICT MILFORD, IOWA. ADDENDUM NO. 2 August 15, 2017 PROJECT 2017-2 TELEMETRY SYSTEM UPGRADES, PHASE 3 IOWA GREAT LAKES SANITARY DISTRICT MILFORD, IOWA CONTRACTOR S BID DATE: PLACE TO FILE FOR CONTRACTOR S BIDS: Tuesday, August 22, 2017, 11:00 A.M. IGLSD

More information

TITLE SHEET FURNISHED BY ACCESS FIBER GROUP, INC.

TITLE SHEET FURNISHED BY ACCESS FIBER GROUP, INC. Cover TITLE SHEET RULES, REGULATIONS, AND SCHEDULE OF RATES AND CHARGES APPLICABLE TO LOCAL EXCHANGE SERVICE WITHIN THE STATE OF MISSOURI MISSOURI PUBLIC SERVICE COMMISSION TELECOMMUNICATIONS TARIFF FURNISHED

More information

DeltaV History Analysis

DeltaV History Analysis January 2013 Page 1 DeltaV History Analysis provides web-based viewing of DeltaV historical data. DeltaV history data available anywhere Integrated batch, continuous and event data Easy-to-use data search

More information

INSTRUCTIONS MANUAL V2.9x B

INSTRUCTIONS MANUAL V2.9x B www.superview.com.br INSTRUCTIONS MANUAL V2.9x B INDEX INDEX... 1 INTRODUCTION... 3 INSTALLATION... 4 SYSTEM REQUIREMENTS... 4 INSTALLATION PROCEDURES... 4 SOFTWARE LANGUAGE SELECTION... 4 FIRST STEPS...

More information

Emergency Dispatch Console Furniture

Emergency Dispatch Console Furniture Request for Proposal Emergency Dispatch Console Furniture Requirements Menominee County E-911 Department s intent is to develop and purchase three (3) standard workstations which will be utilized for Emergency

More information

Concept White Paper. Concepts for Proposed Content of Eventual Standard(s) for Project : Real-Time Monitoring and Analysis Capabilities

Concept White Paper. Concepts for Proposed Content of Eventual Standard(s) for Project : Real-Time Monitoring and Analysis Capabilities Concept White Paper Concepts for Proposed Content of Eventual Standard(s) for Project 2009-02: Real-Time Monitoring and Analysis Capabilities Real-time Monitoring and Analysis Capabilities Standard Drafting

More information

VFD Instead of PLC? VFD s with Embedded Pump Functions Can Replace PLC s in Pumping Applications. yaskawa.com

VFD Instead of PLC? VFD s with Embedded Pump Functions Can Replace PLC s in Pumping Applications. yaskawa.com VFD Instead of PLC? VFD s with Embedded Pump Functions Can Replace PLC s in Pumping Applications yaskawa.com Advancements in PLC and VFD Technology Both variable frequency drives (VFDs) and programmable

More information

The Madison Metropolitan Sewerage District requests quotations for. IP Telephony System

The Madison Metropolitan Sewerage District requests quotations for. IP Telephony System The Madison Metropolitan Sewerage District requests quotations for IP Telephony System Request Madison Metropolitan Sewerage District (MMSD) is soliciting bids for a new IP telephony system. These quotes

More information

PLC 4 PRIMARY SEDIMENTATION SYSTEM SCADA SYSTEM OPERATION MANUAL. Revision 1.0 May 15, 2006

PLC 4 PRIMARY SEDIMENTATION SYSTEM SCADA SYSTEM OPERATION MANUAL. Revision 1.0 May 15, 2006 PLC 4 PRIMARY SEDIMENTATION SYSTEM SCADA SYSTEM OPERATION MANUAL Revision 1.0 May 15, 2006 PLC 4 PRIMARY SEDIMENTATION SYSTEM SCADA SYSTEM OPERATION MANUAL Revision 1.0 May 15, 2006 Table of Contents 1

More information

Inform IT Information Management Tenore. SCADA Extension ABB

Inform IT Information Management Tenore. SCADA Extension ABB ABB Introduction Thanks to the power of its Information Platform, and to the versatility of its architecture, Tenore can easily be employed as a Supervisory and Control Station in a SCADA system for the

More information

Job Sheet 1 The SCADA System Network

Job Sheet 1 The SCADA System Network Job Sheet 1 The Supervisory Control And Data Acquisition (SCADA) system communication network makes it possible for data to be transferred between the central host computer servers, remote terminal unit

More information

SCADA-A2 SCADA System Overview

SCADA-A2 SCADA System Overview PSS 21S 2M2 B3 SCADA-A2 Overview SCADA-A2 is a SCADA system MS Windows? fully operated and compatible, Internet-enabled, designed for Utilities, Oil, Gas, Water, Wastewater, Electric power and multi-services

More information

Evaluation Criteria. 1) Evidence of Credentials / Certifications in all 4 Fields (Energy, GIS, Master Planning, and Real Property): 10 PTS

Evaluation Criteria. 1) Evidence of Credentials / Certifications in all 4 Fields (Energy, GIS, Master Planning, and Real Property): 10 PTS Evaluation Criteria Selection Criteria for: Master Planning and Miscellaneous Engineering Activities [Real Property Inventories, Geospatial Information Systems (GIS Capabilities), Facility Energy Audits,

More information