Sprecher + Schuh offers a broad selection

Size: px
Start display at page:

Download "Sprecher + Schuh offers a broad selection"

Transcription

1 starters II Preassembled or build from stock Easy, fast, economical enclosed starters for applications up to 30HP starters are also available with our advanced EP7 Solid State Overload Relay (select appropriate overload relay code for this option) Sprecher + Schuh offers a broad selection of pre-assembled or build-fromstock starters housed in a high impact, non-metallic, cul Approved, Type 1, 12, 4, or 4x enclosure. Built for convenience, space savings and economy, starters II are efficiently designed to use stock A7 contactors and EP7 or T7N overloads usually stocked by distributors. ontactor and overload are either pre-wired and pre-mounted onto the enclosure s built-in DIN-rail or may be ordered as separate components. Ample knockouts and open terminals guarantee quick, no fuss wiring. Sized for most industrial applications starters II control motors up to 460V in two sizes of enclosures, measuring only 208 x 98mm (7.4 x 3.9 ) or 250 x 125mm (9.85 x 4.93 ) for our larger sizes. This covers over 85% of industrial motor control applications in a very compact package that can be mounted adjacent to or directly on equipment. Top line performance These rugged, modular starters are built with our state-of-the-art A7 Series contactors, noted for their long and reliable service. Bounce free contacts and high contact pressure allow the device to handle high inrush currents with no effect on performance. Thermal overload option starters, sized 9 to 23 amps, are equipped with Sprecher + Schuh s T7N bimetallic thermal overload relay as standard. The consistent high quality of our thermal overload relays is ensured by a complex current calibration procedure performed after each unit is at full operating temperature. alibration is performed at the largest and smallest current the overload can handle. The accurate time/ current characteristic curve obtained in this manner guarantees reliable motor protection every time. Solid state overload options starters II, sizes 9 to 23 amps, can also be supplied with Sprecher + Schuh s EP7 Second Generation solid state overload relay. The EP7 Overload is standard on larger (sizes 30 to 43 amps) and all reversing starters. Unlike traditional overload relays that indirectly sense motor current through heater elements, EP7 solid state overload relays measure motor current directly through integrated current transformers and on board electronics. The electronics provide increased accuracy and numerous other advantages over electromechanical relays. Learn more about Sprecher + Schuh overload relays in Section B of this catalog. No fuss flexibility The enclosure for the starter II is designed for simplicity. The START button mechanically interfaces with a special mounted N.O. contact with minimal wiring. The STOP button also mechanically interfaces with the N.. contact on the overload relay, providing the STOP function. The RESET is provided as standard and functions with no additional wiring. Kwikstarter II s can also be adapted for a 2-wire maintain control circuit. Build it yourself starters may be assembled from stock components. Just grab a A7 contactor and overload of your choice and snap them into the enclosure. Minimal wiring is required and assembly can be completed in minutes. 4

2 starters II Series AK7 & BK7 - A oils starters II with T7N or EP7 Overload Relays; ➊➏ over ontrol/ Single Ø Total Aux. ontacts Installed ode 115V 230V 200V 230V 460V 575V NO N atalog Number ➌ starter with Start & Raised Stop ❹➎ 1/2 1 1/2 ~ ~ ~ ~ BK P2 ~ ~ /2 AK P2 302 Q1 1/2 2 ~ ~ ~ ~ BK P2 ~ ~ /2 10 AK P2 338 Q1 1 3 ~ ~ ~ ~ BK P2 ~ ~ AK P2 363 Q1 2 3 ~ ~ ~ ~ BK P2 ~ ~ 5 7 1/ AK P2 390 Q1 starter with Reset 1/2 1 1/2 ~ ~ ~ ~ BK P0 276 Q1 ~ ~ /2 AK P0 1/2 2 ~ ~ ~ ~ BK P0 313 Q1 ~ ~ /2 10 AK P0 1 3 ~ ~ ~ ~ BK P0 338 Q1 ~ ~ AK P0 2 3 ~ ~ ~ ~ BK P0 ~ ~ 5 7 1/ AK P0 365 Q1 oil odes ➎ A.. Voltage Range ontrol Source oil ode 50 Hz 60 Hz BK7 AK V 120V ommon Separate 208 ~ 208V ~ ommon 220W ~ 208V-240V ommon ommon V 240V ommon ommon V 277V ommon ~ V-400V 440V ~ ommon V 480V ~ ommon V 600V ~ ommon ontrol ircuit Note ommon: oils are assumed to be common with the line voltage and will be connected to the line source (L1-L2) per the table. Separate: oils are assumed to be from a separate source and will not be connected to the line source per the table. This item is available in the ORANGE E PRESS 3-day shipping program See selection guide for details Specify atalog Number Replace (Q) with oil ode See this page See page 8 Important Note: starters II are only designed to accommodate T7N Thermal Overload Relays or EP7 Second Generation Solid State Overload Relays. Select O/L Relay ode from page 8. ➊ starters II are designed for three-wire control circuits. Two-wire (maintain) control can be accomplished by adding pushbutton latch KS7-PLA. ➋ A special design NO auxiliary contact (at.# KS7-PK) is used as the holding circuit interlock, as well as, the START button interface. It is not available for other use. ➌ Refer to page 10.2 for dimensional information. ➍ STOP button also functions as RESET button. Plastic Bezel is standard. ➎ Other voltages available, see Section A. Non-standard coil voltages not listed here must be ordered and installed separately as renewal parts. ➏ Use T7N or EP7-ED/EP7-EE Second Generation overload. 5

3 starters II Series AK7 & BK7 - Electronic 24VD oils starters II with T7N or EP7 Overload Relays; ➊➍➎➏ over ontrol/ Single Ø Total Aux. ontacts Installed ode 115V 230V 200V 230V 460V 575V NO N atalog Number ➌ starter with Start & Raised Stop ❹➎ 1/2 1 1/2 ~ ~ ~ ~ BK7-9E-24E- -P2 379 Q1 ~ ~ /2 AK7-9E-24E- -P2 1/2 2 ~ ~ ~ ~ BK7-12E-24E- -P2 ~ ~ /2 10 AK7-12E-24E- -P2 425 Q1 1 3 ~ ~ ~ ~ BK7-16E-24E- -P2 ~ ~ AK7-16E-24E- -P2 2 3 ~ ~ ~ ~ BK7-23E-24E- -P2 ~ ~ 5 7 1/ AK7-23E-24E- -P2 starter with Reset 1/2 1 1/2 ~ ~ ~ ~ BK7-9E-24E- -P0 ~ ~ /2 AK7-9E-24E- -P0 1/2 2 ~ ~ ~ ~ BK7-12E-24E- -P0 ~ ~ /2 10 AK7-12E-24E- -P0 1 3 ~ ~ ~ ~ BK7-16E-24E- -P0 ~ ~ AK7-16E-24E- -P0 456 Q1 489 Q1 353 Q1 400 Q1 431 Q1 2 3 ~ ~ ~ ~ BK7-23E-24E- -P0 ~ ~ 5 7 1/ AK7-23E-24E- -P0 464 Q1 Specify atalog Number See page 8 Important Note: starters II are only designed to accommodate T7N Thermal Overload Relays or EP7 Second Generation Solid State Overload Relays. Select O/L Relay ode from page 8. ➊ starters II are designed for three-wire control circuits. Two-wire (maintain) control can be accomplished by adding pushbutton latch KS7-PLA. ➋ A special design NO auxiliary contact (at.# KS7-PK) is used as the holding circuit interlock, as well as, the START button interface. It is not available for other use. ➌ Refer to page 10.2 for dimensional information. ➍ STOP button also functions as RESET button. Plastic Bezel is standard. ➎ Only available in 24VD for separate control source. A and D coils are not interchangeable. ➏ Use T7N or EP7-ED/EP7-EE Second Generation overload. 6

4 starters II Series AK7 & BK7 - A and Elec. 24VD oils starters II with T7N or EP7 Overload Relays with H-O-A and Light ➊➋➌➎➏ over ontrol/ Single Ø Total Aux. ontacts Installed ode 115V 230V 200V 230V 460V 575V NO N atalog Number ➍ starter with Reset and H-O-A Selector Switch and Light with A oil 1/2 1 1/2 ~ ~ ~ ~ BK P0+1R7 ~ ~ /2 AK P0+1R7 380 Q1 1/2 2 ~ ~ ~ ~ BK P0+1R7 ~ ~ /2 10 AK P0+1R7 417 Q1 1 3 ~ ~ ~ ~ BK P0+1R7 ~ ~ AK P0+1R7 442 Q1 2 3 ~ ~ ~ ~ BK P0+1R7 ~ ~ 5 7 1/ AK P0+1R7 469 Q1 starter with Reset and H-O-A Selector Switch and Light with Elec. 24VD oil ➐ 1/2 1 1/2 ~ ~ ~ ~ BK7-9E-24E- -P0+1R7 ~ ~ /2 AK7-9E-24E- -P0+1R7 1/2 2 ~ ~ ~ ~ BK7-12E-24E- -P0+1R7 ~ ~ /2 10 AK7-12E-24E- -P0+1R7 1 3 ~ ~ ~ ~ BK7-16E-24E- -P0+1R7 ~ ~ AK7-16E-24E- -P0+1R7 2 3 ~ ~ ~ ~ BK7-23E-24E- -P0+1R7 ~ ~ 5 7 1/ AK7-23E-24E- -P0+1R7 457 Q1 504 Q1 535 Q1 568 Q1 oil odes ➎ A.. Voltage Range ontrol Source oil ode 50 Hz 60 Hz BK7 AK V 120V ommon Separate 208 ~ 208V ~ ommon 220W ~ 208V-240V ommon ommon V 240V ommon ommon D.. Voltage Range ontrol Source oil ode VD BK7 AK7 24E 24V Separate Separate ontrol ircuit Note ommon: oils and pilot devices in the control circuit are assumed to be common with the line voltage and will be connected to the line source (L1-L2) per the table. Separate: oils and pilot devices in the control circuit are assumed to be from a separate source and will not be connected to the line source per the table. Line Voltage not listed: (i.e.: 480 and 575 VA) require a separate control source (i.e.: 120 VA). D7D pilot devices are rated 300 VA maximum. This item is available in the ORANGE E PRESS 3-day shipping program See selection guide for details Specify atalog Number Replace (Q) with oil ode See this page See page 8 Important Note: starters II are only designed to accommodate T7N Thermal Overload Relays or EP7 Second Generation Solid State Overload Relays. Select O/L Relay ode from page 8. ➊ This is a factory assembly. The KS7-0S1 does not include knock-outs for field assembly of this starter. ➋ Uses D7D-P4N_ Red Monolithic Run pilot light with LED bulb. Pilot light voltage to match coil voltage for 24, 120, 240 VA control. Red Run Light can be changed for Green. hange +1R7 to +1G7. For example, AK P0+1R7 becomes AK P0-1G7. ➌ Uses D7D-SM32x20 Monolothic 3-position selector switch for maintain control, HAND-OFF- AUTO function with legend plate. ➍ Refer to page 10 for wiring diagram and 10.2 for dimensional information. This is a clamshell enclosure design with wires to cover controls. ➎ Uses T7N or EP7-ED/EP7-EE Second Generation overload. ➏ One NO auxilliary for customer use. There is no room for additional auxilliaries. ➐ Only available in 24V Electronic D, a separate control source. A and D oils are not interchangeable. Uses D7D-P4N3 Red Monolithic Run pilot light. 6.1

5 NEMA starters II Series AKN7 & BKN7 - A and Elec. 24VD oils NEMA starters II with T7N or EP7 Overload Relays ➊➏ over ontrol/ NEMA Size Single Ø Total Aux. ontacts Installed ode 115V 230V 200V 230V 460V 575V NO N atalog Number ➌ starter with Start & Raised Stop with A oil ❹➎ 1/3 1 ~ ~ ~ ~ BKN P2 ~ ~ 1-1/2 1-1/2 2 2 AKN P2 338 Q1 1 2 ~ ~ ~ ~ BKN P2 ~ ~ AKN P2 363 Q1 starter with Start & Raised Stop with Elec. 24 VD oil ➐ 1/3 1 ~ ~ ~ ~ BKN7-12E-24E- -P2 ~ ~ 1-1/2 1-1/2 2 2 AKN7-12E-24E- -P2 425 Q1 1 2 ~ ~ ~ ~ BKN7-16E-24E- -P2 ~ ~ AKN7-16E-24E- -P2 456 Q1 starter with Reset with A oil 1/3 1 ~ ~ ~ ~ BKN P0 ~ ~ 1-1/2 1-1/2 2 2 AKN P0 313 Q1 1 2 ~ ~ ~ ~ BKN P0 ~ ~ AKN P0 338 Q1 starter with Reset with Elec. 24 VD oil ➐ 1/3 1 ~ ~ ~ ~ BKN7-12E-24E- -P0 ~ ~ 1-1/2 1-1/2 2 2 AKN7-12E-24E- -P0 400 Q1 1 2 ~ ~ ~ ~ BKN7-16E-24E- -P0 ~ ~ AKN7-16E-24E- -P0 431 Q1 oil odes ➎ A.. Voltage Range ontrol Source oil ode 50 Hz 60 Hz BK7 AK V 120V ommon Separate 208 ~ 208V ~ ommon 220W ~ 208V-240V ommon ommon V 240V ommon ommon V 277V ommon ~ V-400V 440V ~ ommon V 480V ~ ommon V 600V ~ ommon ontrol ircuit Note ommon: oils are assumed to be common with the line voltage and will be connected to the line source (L1-L2) per the table. Separate: oils are assumed to be from a separate source and will not be connected to the line source per the table. This item is available in the ORANGE E PRESS 3-day shipping program See selection guide for details Specify atalog Number Replace (Q) with oil ode See this page See page 8 Important Note: starters II are only designed to accommodate T7N Thermal Overload Relays or EP7 Second Generation Solid State Overload Relays. Select O/L Relay ode from page 8. ➊ starters II are designed for three-wire control circuits. Two-wire (maintain) control can be accomplished by adding pushbutton latch KS7-PLA. ➋ A special design NO auxiliary contact (at.# KS7-PK) is used as the holding circuit interlock, as well as, the START button interface. It is not available for other use. ➌ Refer to page 10.2 for dimensional information. ➍ STOP button also functions as RESET button. Plastic Bezel is standard. ➎ Other voltages available, see Section A. Non-standard coil voltages not listed here must be ordered and installed separately as renewal parts. ➏ Use T7N or EP7-ED/EP7-EE Second Generation overload. ➐ Only available in 24V Electronic D for separate control source. A and D oils are not interchangeable. 6.2

6 NEMA starters II Series AKN7 & BKN7 - A & Elec. 24VD oils NEMA starters II with T7N or EP7 Overload Relays with H-O-A and Light ➊➋➌➎➏ over ontrol/ NEMA Size Single Ø Total Aux. ontacts Installed ode 115V 230V 200V 230V 460V 575V NO N atalog Number ➌ NEMA starter with Reset and H-O-A Selector Switch and Light with A oil 00 1/3 1 ~ ~ ~ ~ BKN P0+1R7 1 ➏ 0 ~ ~ 1-1/2 1-1/2 2 2 AKN P0+1R7 417 Q ~ ~ ~ ~ BKN P0+1R7 1 ➏ 0 ~ ~ AKN P0+1R7 442 Q NEMA starter with Reset and H-O-A Selector Switch and Light with Elec 24VD oil ➐ 1/3 1 ~ ~ ~ ~ BKN7-12E-24E- -P0+1R7 1 ➏ Q1 ~ ~ 1-1/2 1-1/2 2 2 AKN7-12E-24E- -P0+1R7 1 2 ~ ~ ~ ~ BKN7-16E-24E- -P0+1R7 1 ➏ Q1 ~ ~ AKN7-16E-24E- -P0+1R7 oil odes ➎ A.. Voltage Range ontrol Source oil ode 50 Hz 60 Hz BK7 AK V 120V ommon Separate 208 ~ 208V ~ ommon 220W ~ 208V-240V ommon ommon V 240V ommon ommon D.. Voltage Range ontrol Source oil ode VD BK7 AK7 24E 24V Separate Separate ontrol ircuit Note ommon: oils and pilot devices in the control circuit are assumed to be common with the line voltage and will be connected to the line source (L1-L2) per the table. Separate: oils and pilot devices in the control circuit are assumed to be from a separate source and will not be connected to the line source per the table. Line Voltage not listed: (i.e.: 480 and 575 VA) require a separate control source (i.e.: 120 VA). D7D pilot devices are rated 300 VA maximum. This item is available in the ORANGE E PRESS 3-day shipping program See selection guide for details Specify atalog Number Replace (Q) with oil ode See this page See page 8 Important Note: starters II are only designed to accommodate T7N Thermal Overload Relays or EP7 Second Generation Solid State Overload Relays. Select O/L Relay ode from page 8. ➊ This is a factory assembly. The KS7-0S1 does not include knock-outs for field assembly of this starter. ➋ Uses D7D-P4N_ Red Monolithic Run pilot light with LED bulb. Pilot light voltage to match coil voltage for 24, 120, 240 VA control. Red Run Light can be changed for Green. hange +1R7 to +1G7. For example, AKN P0+1R7 becomes AKN P0-1G7. ➌ Uses D7D-SM32x20 Monolothic 3-position selector switch for maintain control, HAND-OFF- AUTO function with legend plate. ➍ Refer to page 10 for wiring diagram and 10.2 for dimensional information. This is a clamshell enclosure design with wires to cover controls. ➎ Uses T7N or EP7-ED/EP7-EE Second Generation overload. ➏ One NO auxilliary for customer use. There is no room for additional auxilliaries. ➐ Only available in 24V Electronic D, a separate control source. A and D oils are not interchangeable. Uses D7D-P4N3 Red Monolithic Run pilot light. 6.3

7 starters II Series AK7 & BK7 starter II s with T7N or EP7 Overload Relays ➊➋ For Use With Environmental omponent Description ontactor Overload Approvals atalog Number Flush Green START / Extended Red STOP- Mechanical interface auxiliary contact required. See following page for pricing. KS7-PK included A T7N EP7-ED1 EP7-EE cul Type 1/12/4/4x IE KS7-OS4 70 Blue RESET Only A T7N EP7-ED1 EP7-EE cul Type 1/12/4/4x IE KS7-OS1 45 starter II omponents with T7N or EP7 Overload Relays omponent Description For Use With... atalog Number Start - ontact kit Specially designed NO auxiliary; mechanically interfaces with the START button. Mounts on right side. A KS7-PK is included in every KS7-OS4 enclosure. KS7-OS4 (Renewal Part) KS7-PK 17 Pushbutton Latch - For maintain contact control (2-wire control) KS7-OS4 KS7-PLA 8.50 Neutral Terminal KS7-OS1 KS7-OS4 KS7-PNT 12 Grounding Kit (for use with metal conduit) All Kwikstarter enclosures KS7-GR ➊ starters II are only designed to accommodate A contactors with T7N Thermal Overload Relays or EP7 Second Generation Solid State Overload Relays. Select contactor from Section A and overload relay from Section B in this catalog. ➋ KS7-OS4 and KS7-OS1 may be used with either EP7 Second Generation or T7N (field interchangeable). 7

8 starters II Series AK7 & BK7 starters II with EP7 Solid State Overload Relay 3-Phase Application ➋➌ For use with starter... Amp Range Overload Relay ode ( ) atalog Number (of Overload Relay used) 3-Phase / Manual Reset / lass D1AB EP7-ED1AB D1BB EP7-ED1BB +9 AK7-9...AK D1B EP7-ED1B D1DB EP7-ED1DB D1EB EP7-ED1EB +9 3-Phase / Selectable Function and lass EAB EP7-EEAB EBB EP7-EEBB +17 AK7-9...AK EB EP7-EEB EDB EP7-EEDB EEB EP7-EEEB +17 starters II with EP7 Solid State Overload Relay 1-Phase Application ➋➌ For use with starter... Amp Range Overload Relay ode ( ) atalog Number (of Overload Relay used) 1-Phase / Selectable Function and lass EPB EP7S-EEPB +15 BK7-9...BK ERB EP7S-EERB ESB EP7S-EESB +15 starters II with T7N Bimetallic Overload Relays ➊ For use with Kwikstarter... AK7-9...AK7-23 and BK7-9...BK7-23 Frame A Amp Range Overload Relay ode ( ) atalog Number (of Overload Relay used) AA16 T7N-23-A16 Standard AA25 T7N-23-A25 Standard AA40 T7N-23-A40 Standard AA50 T7N-23-A50 Standard AA63 T7N-23-A63 Standard AA80 T7N-23-A80 Standard AB10 T7N-23-B10 Standard AB13 T7N-23-B13 Standard AB16 T7N-23-B16 Standard AB20 T7N-23-B20 Standard AB25 T7N-23-B25 Standard AB32 T7N-23-B32 Standard AB40 T7N-23-B40 Standard AB48 T7N-23-B48 Standard AB63 T7N-23-B63 Standard AB75 T7N-23-B75 Standard A10 T7N Standard A12 T7N Standard A16 T7N Standard A20 T7N Standard A21 T7N Standard A25 T7N Standard This item is available in the ORANGE E PRESS 3-day shipping program See selection guide for details ➊ If using T7N in single phase application with BK7-9 16, wire per drawing on page 10. ➋ EP7 Overloads are available for use in Starters if the premium features are required (see Section B). ➌ 3-phase EP7-ED or EP7-EE units are only designed for 3 applications. Single phase EP7S units are only designed for 1 applications. If using EP7S, wire per drawing on page 10. 8

9 Now Available starters II Series AK7 & BK7 - A & Elec. 24VD oils starters II with EP7 Overload Relays ➊➐ (KS7-2S4) Single Ø Total Aux. ontacts Installed ode oil odes (Q) ➍➎➏ 115V 230V 200V 230V 460V 575V NO N atalog Number ➌ starters II with A oil 2 5 ~ ~ ~ ~ BK ETD-P ~ ~ 7-1/ AK P 462 Q2 3 5 ~ ~ ~ ~ BK ETD-P ~ ~ AK P 507 Q /2 ~ ~ ~ ~ BK ETD-P ~ ~ AK P 600 Q2 starters II with Electronic 24VD oil ➍ 2 5 ~ ~ ~ ~ BK7-30E-24E-ETD-P ~ ~ 7-1/ AK7-30E-24E- -P 572 Q2 3 5 ~ ~ ~ ~ BK7-37E-24E-ETD-P ~ ~ AK7-37E-24E- -P 633 Q /2 ~ ~ ~ ~ BK7-43E-24E-ETD-P ~ ~ AK7-43E-24E- -P 767 Q2 A.. Voltage Range ontrol Source oil ode 50 Hz 60 Hz BK7 AK V 120V ommon Separate 208 ~ 208V ~ ommon 220W ~ 208V-240V ommon ommon V 240V ommon ommon V 277V ommon ~ V-400V 440V ~ ommon V 480V ~ ommon V 600V ~ ommon Pilot Device Options (includes reset) ➋➏ Specify atalog Number Replace (Q) with oil ode Replace ( ) with Pilot Device Option Replace in catalog number with See this page only Pushbutton Description START-STOP Multi-function 3U Standard I-O Multi-function 4U Standard OFF-ON 2-Position Selector switch 6 Standard HAND-OFF-AUTO 3-Position Selector switch 7 Standard Run Pilot Light Green 1G Standard Run Pilot Light Red 1R Standard Overload Alarm Pilot Light 1Y Standard D7-N8 22mm Hole Plug 0 Standard Optional A7 Modifications (Factory Assembled) Description Add to end of catalog number Electronic Interface -JE +94 Surge Suppressor RD Surge Suppressor Varistor -V +54 Additional N ontact -L Additional NO ontact -L ontrol ircuit Note ommon: oils and pilot devices in the control circuit are assumed to be common with the line voltage and will be connected to the line source (L1-L2) per the table. Separate: oils and pilot devices in the control circuit are assumed to be from a separate source and will not be connected to the line source per the table. Pilot lights are 240 VA maximum. Replace with one of the following Overload Relays For use with starter... Amp Range Overload Relay ode ( ) atalog No. (of Overload Relay used) 3-Phase / Manual Reset / lass D1D EP7-ED1D D1DD EP7-ED1DD +0 AK D1ED EP7-ED1ED D1FD EP7-ED1FD +0 3-Phase / Auto or Manual Reset / lass 10, 15, 20, ED EP7-EED EDD EP7-EEDD +21 AK EED EP7-EEED EFD EP7-EEFD +21 ➊ Use EP7-ED/EP7-EE Second Generation overloads only. Single-phase applications utilize EP7S-EETD only. ➋ Plastic Bezel is standard. Pilot Device options include D7-BX_ Base Mounted contact blocks. See page H68 for more information. ➌ Refer to page 10 for wiring diagram and 10.2 for dimensional information. ➍ Electronic 24VD oils are not interchangeable with other coil sizes or types. ➎ Other voltages available, see Section A. Non-standard coil voltages not listed here must be ordered and installed separately as renewal parts. ➏ One Pilot Device option must be selected. Blanks are not available. If Pilot Light option is selected then Pilot Light must match oil Voltage 24V A or D, 120V or 240V A only. ➐ PT not possible with KS7-2S4 enclosure. 9

10 Now Available starters II / Reversing Series AUK A & Elec. 24VD oils Three Phase Reversing starters II with EP7 Overload Relays ➊➐ (KS7-0S4R) Auxiliary ontacts per ontactor ➑ ode 200V 230V 460V 575V NO N atalog Number ➌ FVR 3-Phase with A oil /2 1 1 AUK P 675 Q / AUK P 745 Q AUK P 790 Q / AUK P 835 Q3 FVR 3-Phase with Electronic 24V D oil /2 1 1 AUK7-9E-24E- -P 829 Q / AUK7-12E-24E- -P 919 Q3 oil odes (Q) ➍➎➏ A.. Voltage Range ontrol Source oil ode 50 Hz 60 Hz BK7 AK V 120V ommon Separate 208 ~ 208V ~ ommon 220W ~ 208V-240V ommon ommon V 240V ommon ommon V 277V ommon ~ V-400V 440V ~ ommon V 480V ~ ommon V 600V ~ ommon Pilot Device Options (includes reset) ➋➏ Specify atalog Number Replace (Q) with oil ode Replace ( ) with Pilot Device Option AUK7-16E-24E- -P 976 Q / AUK7-23E-24E- -P 1033 Q3 Replace in catalog number with See this page ONLY Pushbutton Description FOR-STOP-REV Multi-function 3U Standard UP-STOP-DOWN Multi-function 4U Standard OPEN-STOP-LOSE Multi-function 5U Standard FOR-STOP-REV 3-Position Selector switch 6 Standard UP-OFF-DOWN 3-Position Selector switch 7 Standard OPEN-OFF-LOSE 3-Position Selector switch 8 Standard Overload Alarm Pilot Light 1Y Standard D7-N8 22mm Hole Plug 0 Standard Optional A7 Modifications (Factory Assembled) Description (supplied on each contactor) Add to end of catalog number Electronic Interface -2JE +188 Surge Suppressor RD Surge Suppressor Varistor -2V +108 Additional N ontact -2L Additional NO ontact -2L ontrol ircuit Note ommon: oils and pilot devices in the control circuit are assumed to be common with the line voltage and will be connected to the line source (L1-L2) per the table. Separate: oils and pilot devices in the control circuit are assumed to be from a separate source and will not be connected to the line source per the table. Pilot lights are 240 VA maximum. Replace with one of the following Overload Relays For use with starter... AUK AUK7-9E...23E AUK AUK7-9E...23E Amp Range Overload Relay ode ( ) atalog Number (of Overload Relay used) 3-Phase / Manual Reset / lass D1AB EP7-ED1AB Standard D1BB EP7-ED1BB Standard D1B EP7-ED1B Standard D1DB EP7-ED1DB Standard D1EB EP7-ED1EB Standard 3-Phase / Auto or Manual Reset / lass 10, 15, 20, EAB EP7-EEAB EBB EP7-EEBB EB EP7-EEB EDB EP7-EEDB EEB EP7-EEEB +17 ➊ Use EP7-ED/EP7-EE Second Generation overloads only. ➋ Plastic Bezel is standard. Pilot Device options include D7-BX_ Base Mounted contact blocks. See page H68 for more information. ➌ Refer to page 10.1 for wiring diagram and 10.3 for dimensional information. ➍ Electronic 24VD oils are not interchangeable with other coil sizes or types. ➎ Other voltages available, see Section A. Non-standard coil voltages not listed here must be ordered and installed separately as renewal parts. ➏ One Pilot Device option must be selected. Blanks are not available. If Pilot Light option is selected then Pilot Light must match oil Voltage 24V A or D, 120V or 240V A only. ➐ PT not possible with KS7-0S4R enclosure. ➑ One N.. auxiliary contact is used for electrical interlocking. On AUK7 reversing starters, the N.. contact comes from the Mechanical/Electrical Interlock unit (at# M7-02). 9.1

11 Now Available NEMA starters II Series AKN7 & BKN7 - A & Elec. 24VD oils NEMA starters II with EP7 Overload Relays ➊➐ (KS7-2S4) NEMA Size oil odes (Q) ➍➎➏ Specify atalog Number Replace (Q) with oil ode Replace ( ) with Pilot Device Option Single Ø A.. Voltage Range ontrol Source oil ode 50 Hz 60 Hz BK7 AK V 120V ommon Separate 208 ~ 208V ~ ommon 220W ~ 208V-240V ommon ommon V 240V ommon ommon V 277V ommon ~ V-400V 440V ~ ommon V 480V ~ ommon V 600V ~ ommon Pilot Device Options (includes reset) ➋➏ Total Aux. ontacts Installed ode 115V 230V 200V 230V 460V 575V NO N atalog Number ➌ NEMA starters II with A oil 2 3 ~ ~ ~ ~ BKN ETD-P ~ ~ 7-1/2 7-1/ AKN P 507 Q /2 ~ ~ ~ ~ BKN ETD-P ~ ~ AKN P 600 Q2 NEMA starters II with Electronic 24VD oil ➍ 3 5 ~ ~ ~ ~ BKN7-37E-24E-ETD-P ~ ~ AKN7-37E-24E- -P 633 Q /2 ~ ~ ~ ~ BKN7-43E-24E-ETD-P ~ ~ AKN7-43E-24E- -P 767 Q2 Replace in catalog number with See this page only ontrol ircuit Note ommon: oils and pilot devices in the control circuit are assumed to be common with the line voltage and will be connected to the line source (L1-L2) per the table. Separate: oils and pilot devices in the control circuit are assumed to be from a separate source and will not be connected to the line source per the table. Pilot lights are 240 VA maximum. Pushbutton Description START-STOP Multi-function 3U Standard I-O Multi-function 4U Standard OFF-ON 2-Position Selector switch 6 Standard HAND-OFF-AUTO 3-Position Selector switch 7 Standard Run Pilot Light Green 1G Standard Run Pilot Light Red 1R Standard Overload Alarm Pilot Light 1Y Standard D7-N8 22mm Hole Plug 0 Standard Optional A7 Modifications (Factory Assembled) Description Add to end of catalog number Electronic Interface -JE +94 Surge Suppressor RD Surge Suppressor Varistor -V +54 Additional N ontact -L Additional NO ontact -L Replace with one of the following Overload Relays For use with starter... AK AK Amp Range Overload Relay ode ( ) atalog Number (of Overload Relay used) 3-Phase / Manual Reset / lass D1D EP7-ED1D D1DD EP7-ED1DD D1ED EP7-ED1ED D1FD EP7-ED1FD +0 3-Phase / Auto or Manual Reset / lass 10, 15, 20, ED EP7-EED EDD EP7-EEDD EED EP7-EEED EFD EP7-EEFD +21 ➊ Use EP7-ED/EP7-EE Second Generation overloads only. Single-phase applications utilize EP7S-EETD only. ➋ Plastic Bezel is standard. Pilot Device options include D7-BX_ Base Mounted contact blocks. See page H68 for more information. ➌ Refer to page 10 for wiring diagram and 10.2 for dimensional information. ➍ Electronic 24VD oils are not interchangeable with other coil sizes or types. ➎ Other voltages available, see Section A. Non-standard coil voltages not listed here must be ordered and installed separately as renewal parts. ➏ One Pilot Device option must be selected. Blanks are not available. If Pilot Light option is selected then Pilot Light must match oil Voltage 24V A or D, 120V or 240V A only. ➐ PT not possible with KS7-2S4 enclosure. 9.2

12 Now Available NEMA starters II / Reversing Series AUKN7 - A & Elec. 24VD oils Three Phase Reversing NEMA starters II with EP7 Overload Relays ➊➐ (KS7-0S4R) NEMA Size Auxiliary ontacts per ontactor ➑ ode 200V 230V 460V 575V NO N atalog Number ➌ 3-Phase FVR NEMA starter with A oil /2 1-1/ AUKN P 745 Q AUKN P 790 Q3 3-Phase FVR NEMA starter with Electronic 24V D oil /2 1-1/ AUKN7-12E-24E- -P 919 Q AUKN7-23E-24E- -P 1033 Q3 oil odes (Q) ➍➎➏ A.. Voltage Range ontrol Source oil ode 50 Hz 60 Hz BK7 AK V 120V ommon Separate 208 ~ 208V ~ ommon 220W ~ 208V-240V ommon ommon V 240V ommon ommon V 277V ommon ~ V-400V 440V ~ ommon V 480V ~ ommon V 600V ~ ommon Pilot Device Options (includes reset) ➋➏ Specify atalog Number Replace (Q) with oil ode Replace ( ) with Pilot Device Option Replace in catalog number with See this page ONLY Pushbutton Description FOR-STOP-REV Multi-function 3U Standard UP-STOP-DOWN Multi-function 4U Standard OPEN-STOP-LOSE Multi-function 5U Standard FOR-STOP-REV 3-Position Selector switch 6 Standard UP-OFF-DOWN 3-Position Selector switch 7 Standard OPEN-OFF-LOSE 3-Position Selector switch 8 Standard Overload Alarm Pilot Light 1Y Standard D7-N8 22mm Hole Plug 0 Standard Optional A7 Modifications (Factory Assembled) Description (supplied on each contactor) Add to end of catalog number Electronic Interface -2JE +188 Surge Suppressor RD Surge Suppressor Varistor -2V +108 Additional N ontact -2L Additional NO ontact -2L ontrol ircuit Note ommon: oils and pilot devices in the control circuit are assumed to be common with the line voltage and will be connected to the line source (L1-L2) per the table. Separate: oils and pilot devices in the control circuit are assumed to be from a separate source and will not be connected to the line source per the table. Pilot lights are 240 VA maximum. Replace with one of the following Overload Relays For use with starter... AUKN AUKN7-12E..16E AUKN AUKN7-12E..16E Amp Range Overload Relay ode ( ) atalog Number (of Overload Relay used) 3-Phase / Manual Reset / lass D1AB EP7-ED1AB Standard D1BB EP7-ED1BB Standard D1B EP7-ED1B Standard D1DB EP7-ED1DB Standard D1EB EP7-ED1EB Standard 3-Phase / Auto or Manual Reset / lass 10, 15, 20, EAB EP7-EEAB EBB EP7-EEBB EB EP7-EEB EDB EP7-EEDB EEB EP7-EEEB +17 ➊ Use EP7-ED/EP7-EE Second Generation overloads only. ➋ Plastic Bezel is standard. Pilot Device options include D7-BX_ Base Mounted contact blocks. See page H68 for more information. ➌ Refer to page 10.1 for wiring diagram and 10.3 for dimensional information. ➍ Electronic 24VD oils are not interchangeable with other coil sizes or types. ➎ Other voltages available, see Section A. Non-standard coil voltages not listed here must be ordered and installed separately as renewal parts. ➏ One Pilot Device option must be selected. Blanks are not available. If Pilot Light option is selected then Pilot Light must match oil Voltage 24V A or D, 120V or 240V A only. ➐ PT not possible with KS7-0S4R enclosure. ➑ One N.. auxiliary contact is used for electrical interlocking. On AUKN7 reversing starters, the N.. contact comes from the Mechanical/Electrical Interlock unit (at# M7-02). 9.3

13 Now Available starters II Series AK7/BK /AUK starter II s for use with A7 ontactors and Overload Relays ➌ omponent Description ontactor For Use With Overload Environmental Approvals atalog Number for starter II ➊ AK7/BK AK7/BK7-30E 43E A A7-30E 43E EP7-ED1D ED1FD EP7-EED EEFD EP7S-EETD cul Type 1/12/4/4x IE KS7-2S4 110 for Reversing starter II ➋ AUK AUK7-9E 23E AU AU7-9E...23E EP7-ED1AB ED1EB EP7-EEAB EEEB starter II Pilot Device Kits (for use with KS7-2S4 or KS7-0S4R) ➌➍ Kits Description Multi-Function Pushbutton kit Non-illuminated START-STOP I-O FOR-STOP-REV UP-STOP-DOWN OPEN-STOP-LOSE Selector switch kits Non-illuminated, includes legend plate For Use With... KS7-2S4 Type 1, 12, 4, 4X KS7-0S4R Type 1, 12, 4, 4X cul Type 1/12/4/4x IE ontact Blocks included NO N atalog Number KS7-P3U KS7-P4U KS7-P3U-REV KS7-P4U-REV KS7-P5U-REV KS7-0S4R ON-OFF 2-Position KS7-2S4 1 - KS7-P6 41 HAND-OFF-AUTO 3-Position Type 1, 12, 4, 4X 2 - KS7-P7 54 FOR-OFF-REV 3-Position UP-OFF-DOWN 3-Position OPEN-OFF-LOSE 3-Position Run Pilot Light or Overload Alarm Pilot Light Plastic operator with diffuser lens in Red, Green or Yellow, with integrated LED power module KS7-0S4R Type 1, 12, 4, 4X KS7-2S4 or KS7-0S4R Type 1, 12, 3R, 4, 4X Replace with color choice R = Red G = Green Y = Yellow KS7-P6-REV KS7-P7-REV KS7-P8-REV KS7-P1 24V ➏ KS7-P1 120V KS7-P1 240V Reset Pushbutton, Blue Plastic, flush operator with Blue ap and R text KS7-2S4 KS7-0S4R - - D7P-F611 ➎ See page H4 ➊ starter enclosure KS7-2S4 are designed to fit A contactors with EP7 Overload Relays. T7N Thermal Overloads can not be substituted. ➋ starter enclosure KS7-0S4R are designed to fit AU reversing contactors with EP7 Overload Relays. T7N Thermal Overloads can not be substituted. ➌ KS7-2S4 and KS7-0S4R are supplied with two 22mm holes for Pilot Devices. A Reset is required and one additional pilot device kit from this page must be selected. PT not possible. ➍ Plastic bezel is standard. Pilot Device Kits include D7-BX_ Base Mounted contact blocks. See page H68 for more information. ➎ D7P-R611 and EP7-ERA can not be used with KS7-2S4 or KS7-0S4R. ➏ KS7-P1 24V can be used with 24V A or 24V D. 9.4

14 [10mm] Inch 1 SALE: Wiring Diagrams starters II starter II (in enclosure KS7-0S1/0S4) USTOMER MUST PROVIDE PROPER BRANH IRUIT PROTETION (F1) SEE THE APPLIATION INSTRUTION SHEET - OMPONENT SELETION TABLES FOR MAX. FUSE SIZE & LASS AND APPLIABLE SHORT IRUIT RATING (USE 75º OPPER WIRE ONLY) THIS DRAWING IS FOR THE FOLLOWING ENLOSURES: KS7-0S4 with integrated START-STOP push buttons KS7-0S1 with integrated RESET push button NOTES: 1) MEHANIAL LATH KS7-PLA FOR MAAINTAINED ONTROL (OPTIONAL). 2) START ONTAT KIT KS7-PK (INLUDED) MOUNTS ON THE RIGHT SIDE WITH MOLDED PRE-FORMED JUMPERS. 3) DO NOT WIRE ONTROLS IRUIT TO LINE SIDE OF ONTATOR WHEN OIL VOLTAGE IS 120V OR LESS. (FATORY WIRING STANDARD) 4) OPTIONAL PILOT LIGHTS. starter II (in enclosure KS7-0S1/0S4) with HOA option HAND-OFF-AUTO with Pilot Light A.. Voltage Range ontrol Source oil ode 50 Hz 60 Hz BK7 AK V 120V ommon Separate 208 ~ 208V ~ ommon 220W ~ 208V-240V ommon ommon V 240V ommon ommon D.. Voltage Range ontrol Source oil ode VD BK7 AK7 24E 24V Separate Separate 10

15 Wiring Diagrams starters II starter II (in enclosure KS7-2S4) starter II (in enclosure KS7-0S4R) 10.1

16 [10mm] 1 Inch SALE: [10mm] 1 Inch SALE: s starters II starter II KS7-0S1/0S4 ( ode Q1) s are in millimeters (inches). s not intended for manufacturing purposes Extended STOP [0.99] HAND-OFF-AUTO with Pilot Light 19.5 [0.77] 44.5 [1.75] [8.19] 188 [7.41] [0.94] [1.24] 60.3 [2.38] 68 [2.68] 36.5 [1.44] 188 mm Ø " 0.2" DIA 188 [7.41] 36.5 [1.44] 205 [8.08] ø5.3 [ ø0.21] 97.9 [3.86] 111 [4.37] 5.5 [0.22] 111 [4.37] 27.9 [1.10] 111 [4.37] ø20.3 [ ø0.80] ø25.3 [ø 1.00] 51 [2.01] [0.22] [0.94] starter II KS7-2S4 ( ode Q2) 125 [4.93] 125 [4.93] 16 [0.63] 250 [9.85] 3.5 [0.14] Ø23 [Ø0.91] 169 [6.66] 13 [0.51] [4.48] 235 [9.26] 78 [3.07] 30 [1.18] 50 [1.97] 110 [4.33] 125 [4.93] 50 [1.97] 24 [0.95] 28.1 [1.11] Rotary operator alternatively (for maintained control) 50 [1.97] 10 Pozidriv No. 2 (1.2 x 6.5) 2.0 Nm 18 lb-in 2 x mm² 2 x No AWG Pozidriv No Nm 20 lb-in 10.2

17 s starters II starter II KS7-0S4R ( ode Q3) s are in millimeters (inches). s not intended for manufacturing purposes. 125 [4.93] 125 [4.93] 16 [0.63] 250 [9.85] 13 [0.51] 3.5 [0.14] Ø23 [Ø0.91] 28.1 [1.11] 10 Pozidriv No. 2 (1.2 x 6.5) 2.0 Nm 18 lb-in 2 x mm² 2 x No AWG Pozidriv No Nm 20 lb-in 235 [9.26] 100 [3.94] [4.39] 30 [1.18] 88.6 [3.49] 125 [4.93] 50 [1.97] 24 [0.95] 50 [1.97] 50 [1.97] 110 [4.33] Rotary operator alternatively (for maintained control) 10.3

Sprecher + Schuh offers a broad selection

Sprecher + Schuh offers a broad selection Preassembled or build from stock Easy, fast, economical enclosed starters for applications up to 30HP Most are equipped with Thermal Overload protection as standard Sprecher + Schuh offers a broad selection

More information

Enclosed Non-Reversing Combination Controller, AC Operation - Type 1/12K/IP66 ➏➐ (KS7-C0C4R) Discount Schedule F-1

Enclosed Non-Reversing Combination Controller, AC Operation - Type 1/12K/IP66 ➏➐ (KS7-C0C4R) Discount Schedule F-1 KWIKstarter/CX7 CX7 Non-Reversing Combination Controller, AC Enclosed Non-Reversing Combination Controller, AC Operation - Type 1/12K/IP66 ➏➐ ~ ~ ~ ~ 0.10 0.16 2.1 1 CX7-9-10- -AS0.16A-A10-PG 551 Q4 ~

More information

Enclosed Non-Reversing Combination Controller, AC Operation - Type 1/12K/IP66 ➏➐. Non-Metallic Type 1/12K/IP66 Enclosure (KS7-C0C4R)

Enclosed Non-Reversing Combination Controller, AC Operation - Type 1/12K/IP66 ➏➐. Non-Metallic Type 1/12K/IP66 Enclosure (KS7-C0C4R) KWIKstarter/CX7 CX7 Non-Reversing Combination Controller, AC Enclosed Non-Reversing Combination Controller, AC Operation - Type 1/12K/IP66 ➏➐ Catalog Number ➍➏➑➒ ~ ~ ~ ~ 0.10 0.16 2.1 1 CX7-9-10- -AS0.16A-A10-PG

More information

PRODUCT PROFILE BULLETIN 193 & 592 E1 PLUS ELECTRONIC OVER LOAD RELAYS

PRODUCT PROFILE BULLETIN 193 & 592 E1 PLUS ELECTRONIC OVER LOAD RELAYS PRODUCT PROFILE BULLETIN 193 & 592 E1 PLUS ELECTRONIC OVER LOAD RELAYS FEATURES IEC and NEMA configurations Self-Powered Phase Loss Protection Wide 5:1 Adjustment Range Over-Molded Power Connections 1

More information

29 $ Manual Motor Starters FREESHIPPING. MOTOR CONTROLS 25. Features: MMS-32H Frame. MMS-63H Frame.

29 $ Manual Motor Starters FREESHIPPING.  MOTOR CONTROLS 25. Features: MMS-32H Frame. MMS-63H Frame. www.factorymation.com/motorcontrols MOTOR CONTROLS 25 Manual Motor Starters High interrupt capacity Din rail and surface mounting Lockable handle (OFF position) IP20 finger safe terminals Class 10 thermal

More information

Technical Information

Technical Information Technical Information Short Circuit Ratings KT7 Assembly Application Rating Chart (Ratings are dependent on type of application) ➊ Rating Index Assembly Components Manual Controller or Group Installation

More information

Controls Enclosed Non-Combination Starters - PESW Series

Controls Enclosed Non-Combination Starters - PESW Series NEMA 4/4X Non Metallic Enclosure Product Features WEG offers non-reversing and non-combination NEMA-4X magnetic starter up to 75HP at 460V. Featuring components that meet IEC design standards and UL horsepower

More information

Mini Contactors & Overloads

Mini Contactors & Overloads 108 Mini s & Overloads GMC-12M Surface or DIN rail mountable UL508 compliant 1/ to 7-1/ 50/60Hz AC and DC versions available Direct-mounting overloads RoHS compliant Auxiliary contacts standard (1 N.0.)

More information

CS8 Industrial Control Relays

CS8 Industrial Control Relays CS8 Industrial Control Relays Despite increasing complexity, control systems and installations must become increasingly compact. And the CS8 Miniature Relay System packs maximum performance into minimum

More information

Contactors and Contactor Assemblies

Contactors and Contactor Assemblies RT contactors, size S00 The product range at a glance The new generation is a complete, modular system family, logically designed right down to the last detail, from the basic units to the accessories.

More information

Series Panel Mounted Control Devices

Series Panel Mounted Control Devices E_Master2012.qxd:NEW_E_Master_temp.qxd 1/27/12 4:28 PM Page 1 Series Features: Suitable for hazardous and corrosive locations. Installation is easy and precise. Devices fit into a standard 30.5mm, 1.2"

More information

CS7 Industrial Control Relays

CS7 Industrial Control Relays CS7 Industrial Control Relays Reliable, general purpose relays for heavy duty applications The base four pole CS7 relay can be expanded up to twelve poles with the addition of front and side mount auxiliaries

More information

Table 1. IEC Power Control Devices. Type Description Cost Electrical Operations. Soft starters or drives that gradually start and stop motors.

Table 1. IEC Power Control Devices. Type Description Cost Electrical Operations. Soft starters or drives that gradually start and stop motors. IEC Power Control Devices Training Manual XT Training Module New Information March 08 Contents Description Page Overview..................... Contactors................... Overload Relays (Bimetal).......

More information

Series CA7 Contactors

Series CA7 Contactors Series Rugged, space saving and modular Sprecher + Schuh s newest contactor for applications up to 6HP Over years of design experience has produced Sprecher + Schuh s seventh generation contactor line.

More information

OVERLOAD RELAYS POWER & ACTUATION PROVEN. series

OVERLOAD RELAYS POWER & ACTUATION PROVEN. series POWER & ACTUATION OVERLOAD RELAYS series Need reliable, accurate overload and phase-loss protection for your motors? c3controls Series Bimetallic Overload Relays provide unmatched protection and can be

More information

Series CA7 Contactors

Series CA7 Contactors C7 Series C7 Rugged, space saving and modular Sprecher + Schuh s newest contactor for applications up to 6HP Over years of design experience has produced Sprecher + Schuh s seventh generation contactor

More information

3RT, 3TB, 3TF Contactors for Switching Motors

3RT, 3TB, 3TF Contactors for Switching Motors RT, TB, TF Contactors for Switching Motors Overview RT contactors and coupling relays Size S00 with mountable accessories The SIRIUS generation of controls is a complete, modular system family, logically

More information

For full product information, visit Use the SpeedSpec code or scan the QR Code for quick access to the specific web page.

For full product information, visit  Use the SpeedSpec code or scan the QR Code for quick access to the specific web page. R Safety Monitoring Relays For full product information, visit www.sti.com. Use the SpeedSpec code or scan the QR Code for quick access to the specific web page. Dual-Channel Safety Monitoring Relay Power

More information

IMS Control & EPR, We keep your motors running ABB s new control & protection devices up to 18.5 kw / 20 hp

IMS Control & EPR, We keep your motors running ABB s new control & protection devices up to 18.5 kw / 20 hp IMS Control & EPR, 2010 01 29 We keep your motors running ABB s new control & protection devices up to 18.5 kw / 20 hp October 27, 2010 1SBC101089D0201 ABB s new control and protection devices Up to 18.5

More information

sirius Switching. Protecting. Starting. SIRIUS Product Overview

sirius Switching. Protecting. Starting. SIRIUS Product Overview sirius Switching. Protecting. Starting. SIRIUS Product Overview S00 Design Direct-on-line starting Reversing duty Assembly kit for busbar mounting 0 mm: RA9 -C 0 mm: RA9 -D Consisting of: wiring kit busbar

More information

IPS INTELLIGENT PUMP STARTER

IPS INTELLIGENT PUMP STARTER IPS INTELLIGENT PUMP STARTER The IPS Intelligent Pump Starter features SMARTSTART motor protection, integrated electronic pump protection overload, and power metering and data logging options. Ø & Ø, 0/60

More information

Micro Contactor MA Series

Micro Contactor MA Series Relay-sized contactor, making it the world s smallest >3mm contact clearance acc. to IEC 60335-1 for Safety Applications Reversing contactor with mechanical interlock 3 Pole and 1 Aux. Contact NO or NC

More information

3RA13, 3RA14 Contactor Assemblies

3RA13, 3RA14 Contactor Assemblies RA1, RA Contactor Assemblies RA1 complete units,... kw Overview The RA1 reversing contactor assemblies can be ordered as follows: Sizes S00 to S Fully wired and tested, with mechanical and electrical interlock

More information

Bulletin 193 E1 Plus Solid-State Overload Relays

Bulletin 193 E1 Plus Solid-State Overload Relays Bulletin 193 E1 Plus Solid-State Overload Relays E1 Plus Solid-State Overload Relays Self-powered Phase loss protection Wide adjustment range (5:1) Over-molded power connections 1 N.O. and 1 N.C. isolated

More information

Contacts Contact Arrangement. 8-Pole Relay. 12-Pole Relay

Contacts Contact Arrangement. 8-Pole Relay. 12-Pole Relay Bulletin -P Heavy-Duty Industrial s Product Selection DC-Operated s Rail Mount DIN Rail Mount Cat. No. Cat. No. -Pole DC-P DC-PD DC-P DC-PD -Pole DC-P DC-PD DC-P DC-PD -Pole DC-P DC-PD DC-P DC-PD DC Coil

More information

Starters. Power. Manual Motor Low Voltage Starters 600, 609, 609U, 609TU. 600 Manual Starting Switches 609 Manual Starting Switches

Starters. Power. Manual Motor Low Voltage Starters 600, 609, 609U, 609TU. 600 Manual Starting Switches 609 Manual Starting Switches Starters Manual Motor Low Voltage Starters 600, 609, 609U, 609TU Compact design Undervoltage protection Manual operation with overload protection Ideal for low HP applications, up to 10 HP three phase

More information

Time Delay Values (A, B, C & D-Series) AC 10000

Time Delay Values (A, B, C & D-Series) AC 10000 Time Delay Values (A, B, & D-Series) A 0 Instantaneous INSTANTANEOUS URVE. 20 0 D D.. INSTANTANEOUS URVE. 0 TRIP TIME IN SEONDS 0. TRIP TIME IN SEONDS 0..0.0 Ultrashort.00 0 200 300 400 500 600 700 800

More information

Safety Monitoring Relays

Safety Monitoring Relays Safety Monitoring Relays Contents Selection Guide I-2 Safety Monitoring Relays G9SA I-6 SR101A I-12 SR103AM I-13 SR104P I-17 SR105E I-17 SR106ED I-21 SR108AD & SR109AD I-18 SR120MP I-21 SR125SMS45 I-22

More information

Smartstart Control Module

Smartstart Control Module Smartstart TECHNOLOGY What is Smartstart? The patented Smartstart control module is an integrated, seamless solution that incorporates operator control, superior motor protection, and automation system

More information

Bulletin 193 E1 Plus Solid-State Overload Relays

Bulletin 193 E1 Plus Solid-State Overload Relays Bulletin 193 E1 Plus Solid-State Overload Relays E1 Plus Solid-State Overload Relays Self-powered Phase loss protection Wide adjustment range (5:1) Over-molded power connections 1 N.O. and 1 N.C. isolated

More information

22mm Non Illuminated Metal Operators

22mm Non Illuminated Metal Operators 22mm 22mm Non Illuminated Metal Operators Altech Corp. can provide other push button and actuator options. If your requirement calls for a 22 mm operator which is not shown, please do not hesitate to call.

More information

24973 Circuit Breaker MINIATURE CIRCUIT BREAKER, 440VAC, 10A, CIRCUIT BREAKER TYPE: STANDARD

24973 Circuit Breaker MINIATURE CIRCUIT BREAKER, 440VAC, 10A, CIRCUIT BREAKER TYPE: STANDARD United States 24973 Circuit Breaker MINIATURE CIRCUIT BREAKER, 440VAC, 10A, CIRCUIT BREAKER TYPE: STANDARD Image not available Product Information Features and Specifications Approvals: IEC 60947-2 Rated

More information

PG Softstarter Installation Manual for 5A, 9A and 16A Controllers

PG Softstarter Installation Manual for 5A, 9A and 16A Controllers PG Softstarter Installation Manual for 5A, 9A and 16A Controllers Important User Information The examples and diagrams in this manual are included solely for illustrative purposes. Because of the many

More information

Magnetically Actuated Safety Interlock Switches

Magnetically Actuated Safety Interlock Switches Conforms to EN10, EN292, EN020-1 CSA and BG approved Actual Size Magnetically Actuated Safety Interlock Switches Large selection choose from a large selection of contact configurations housed in plastic,

More information

onlinecomponents.com

onlinecomponents.com ccessories Field Installable Top (Front) Mount uxiliary Contact Blocks ➊ Contact Block NO NC Top mount auxiliary contact blocks snap-on to the top (front) of any contactor 4-pole auxiliary 2-pole auxiliary

More information

CS7 Industrial Control Relays

CS7 Industrial Control Relays CS7 Industrial Control Relays Reliable, general purpose relays for heavy duty applications The base four pole CS7 relay can be expanded up to twelve poles with the addition of front and side mount auxiliaries

More information

Enclosed DOL Motor Starter Type 4x, Plastic, 3-Phase

Enclosed DOL Motor Starter Type 4x, Plastic, 3-Phase Enclosed DOL Starter Type x, Plastic, Phase C US LISTED ENCLOSED INDUSTRIAL CONTROL PANEL WIRING SPECIFICATIONS CONTROL/COIL VOLTAGE: LINE (LINE) START/STOP (STSR) START STOP //8 //8 Customer Supplied

More information

SMARTSTART MOTOR STARTERS

SMARTSTART MOTOR STARTERS SMARTSTART MOTOR STARTERS MCG WWW.MCG-USA.COM 1 AT A GLANCE Covers all line voltages from 200-600V AC, single or three phase Transformer supplies a 24V AC coil voltage, no matter the line voltage 12V AC/DC

More information

MOTOR PROTECTION CIRCUIT BREAKERS

MOTOR PROTECTION CIRCUIT BREAKERS MOTOR PROTECTION CIRCUIT BREAKERS PAGE -2 PAGE -2 SMA Thermal trip adjustment ranges 9-32A (5 choices) Breaking capacity Icu at 400V: 50kA Suitable for mounting in consumer switchboards with minimum 58mm

More information

193 EE C B. Adjustment Range [A] Code Description Code Description A P C C EEDB 100-C C97

193 EE C B. Adjustment Range [A] Code Description Code Description A P C C EEDB 100-C C97 Bulletin -ED/-EE E Plus Electronic Overload Relays Catalog Number Explanation/Product Selection Code a Bulletin Number Description IEC Three-Phase S IEC Single-Phase NEMA Three-Phase S Code NEMA Single-Phase

More information

PERCENT OF RATED CURRENT

PERCENT OF RATED CURRENT A-D Series Time Delay Values PERENT OF RATED URRENT NOTES: UL489 -Series Breakers available with Delay urves 11, 12, 14, 16, 21, 22, 24, 26, 42, 44, 46. Delay urves 11,12,14,16,21,22,24,26,42,44,46,52,54,56:

More information

Bulletin 700-HA Tube Base Relay

Bulletin 700-HA Tube Base Relay Bulletin 700-HA Tube Base Relay Bulletin 700 HA Tube Base Relay 10 A contact rating DPDT, 3PDT Pin-style terminals Standard ON/OFF flag indicator Options: LED, push-to-test and manual override, socket-mounted

More information

4-Pole Relay. 2 Coil. [V] Hz A1 A2 60 Hz A24 A1 A20 A2

4-Pole Relay. 2 Coil. [V] Hz A1 A2 60 Hz A24 A1 A20 A2 ulletin - Product Overview/Product Selection ulletin - Industrial Relay ontact cartridges convertible from.o. to.. and vice versa EM V coils Pneumatic timing unit Solid-state timing unit Overlap contacts

More information

DAW 8/28/09. TITLE Specification I2R 120/240 RR 120V AC Split Phase Surge Protector PAGE 1 of 9 REVISIONS

DAW 8/28/09. TITLE Specification I2R 120/240 RR 120V AC Split Phase Surge Protector PAGE 1 of 9 REVISIONS These commodities/technical data are controlled for export by the U.S. State Department. They may not be transferred, transshipped on a noncontinuous voyage, or otherwise be disposed of outside of the

More information

AE/CE Series Industrial Control Transformers

AE/CE Series Industrial Control Transformers 5 AE/E Series Industrial ontrol Transformers SETION TA AE/E SERIES SERIES OPEN ORE INDUSTRIAL & OIL INDUSTRIAL ONTROL ONTROL TRANSFORMERS The Acme Electric AE and E Series Industrial ontrol Transformers

More information

Bulletin 700-P, 700DC-P Industrial Relays

Bulletin 700-P, 700DC-P Industrial Relays Bulletin 700-P, 700DC-P Industrial Relays Bulletin 700 P Direct Drive Convertible Contact Cartridge Relays NEMA and IEC ratings 600V maximum AC/DC Accessories for field installation: contact cartridges,

More information

1.1. Contactors and Starters... Contents Description Relays and Timers... Miniature Controls... Manual Motor Protectors. XT IEC Power Control

1.1. Contactors and Starters... Contents Description Relays and Timers... Miniature Controls... Manual Motor Protectors. XT IEC Power Control . Contents Description Relays and Timers......................... Miniature Controls......................... Contactors and Starters.................... Thermal Overload Relays.................... C440/XT

More information

Contactors and Contactor Assemblies

Contactors and Contactor Assemblies SIRIUS Contactors and Contactor Assemblies Application WYE-delta starting can only be used either if the motor normally operates in a d (delta) connection or starts softly or if the load torque during

More information

Model 720 Electromechanical Hour Meter

Model 720 Electromechanical Hour Meter Model 720 Electromechanical Hour Meter A 5 figure (reset) or 6 figure (non-reset), AC hour meter encased in a rugged steel housing and designed to mil-spec environmental requirements. The non-reset models

More information

Custom Switchracks: Built to Comply with NEC/CEC Standards From Design to Installation, Appleton is The Switchrack Authority

Custom Switchracks: Built to Comply with NEC/CEC Standards From Design to Installation, Appleton is The Switchrack Authority From Design to Installation, Appleton is The Switchrack Authority With over 80 years in the industry, Appleton is one of the first and the most respected names in custom switchracks for hazardous and adverse

More information

Magnetic Style Safety Interlock Switches

Magnetic Style Safety Interlock Switches Non-contact safety interlock switches are the best choice for washdown applications; the switch components are sealed and rated NEMA 4X, IEC IP67 Tolerant of dirt buildup, sensing distance, and alignment

More information

Bulletin 193, 825-P, 809, 813, 817, 819 Motor Protection Quick Selection Table

Bulletin 193, 825-P, 809, 813, 817, 819 Motor Protection Quick Selection Table Overload Relays Bulletin 93, 825-P, 809, 83, 87, 89 Quick Selection Table Type Bulletin No. 93-ED 93-EE 93-M 93-CT E Plus Electronic Overload Relay Bimetallic Overload Relay Bimetallic Overload Relay Rated

More information

78 Series Electromechanical Relay Selection Guide

78 Series Electromechanical Relay Selection Guide 78 Series Electromechanical Relay Selection Guide Specification 781 Series 782 Series 783 Series 784 Series Coil Voltages Configuration SPDT DPDT 3PDT 4PDT Contact Rating 15A 15A 15A 15A Base Socket 5

More information

AE/CE Series Industrial Control Transformers

AE/CE Series Industrial Control Transformers AE/E SERIES INDUSTRIAL ONTROL TRANSFORMERS AE/E Series Industrial ontrol Transformers The Acme Electric AE and E Series Industrial ontrol Transformers are designed specifically for machine tool control

More information

Expansion Unit Catalog Nos , - 152, - 153, - 154, - 156, -E157

Expansion Unit Catalog Nos , - 152, - 153, - 154, - 156, -E157 PRODUCT DA TA SLC 150 110 Expansion Unit Catalog Nos. 1745-151, - 152, - 153, - 154, - 156, -E157 7 : The EXpdnSiQn Unit The SLC 150 expansion unit can be used with either the SLC 150 processor unit or

More information

Crane Control Class 9004

Crane Control Class 9004 Catalog 17 CONTENTS Description.....................................................Page Pricing and Ordering Information...................................... 140 Dimensions and Weights............................................

More information

Magnetically Actuated Safety Interlock Switches

Magnetically Actuated Safety Interlock Switches Rev. 7.07 C US Conforms to EN1088, EN292, EN6020-1 CSA approved MA Series Magnetically Actuated Safety Interlock es Large selection choose from a large selection of contact configurations housed in plastic

More information

Quantum III. Compact DC Drive Package. Slitter DC Drive Package. Quantum III

Quantum III. Compact DC Drive Package. Slitter DC Drive Package. Quantum III Compact DC Drive Package The delivers a DC drive package that integrates the intelligence of the Mentor II with a space saving design that incorporates many accessories typically required in the North

More information

Electronic Motor Protection Relays Bulletin 193-E

Electronic Motor Protection Relays Bulletin 193-E Electronic otor Protection Relays Bulletin 93-E 93-EB also includes: Trip Class 0, or 0 selectable Ground Fault Protection Jam/Stall Protection Product Selection... -3 ccessories dd-on ccessories... -

More information

Mini Contactors. Mini Contactor Relays 4-pole 20 Auxiliary Contact Blocks. Interface Contactor Relays. Mini Contactors 22 Auxiliary Contact Blocks

Mini Contactors. Mini Contactor Relays 4-pole 20 Auxiliary Contact Blocks. Interface Contactor Relays. Mini Contactors 22 Auxiliary Contact Blocks Mini Contactors Mini Contactor Relays 4-pole 20 Auxiliary Contact Blocks Interface Contactor Relays Mini Contactors 22 Auxiliary Contact Blocks Mini Contactors With Fast On Tab Connectors 24 Mini Contactors

More information

ASCO 920 Remote Control (RC) Switches

ASCO 920 Remote Control (RC) Switches Maximum reliability and excellent value ASCO 920 Remote Control (RC) Switches ASCO 920 Remote Control Switch in Type Enclosure The ASCO 920 is designed as a feeder disconnect switch for load capacities

More information

8WH5 Combination Plug-In Terminals

8WH5 Combination Plug-In Terminals 8WH Combination Plug-In Terminals /2 Introduction / 8WH through-type terminals 1) /7 8WH hybrid through-type terminals with ipo connection /8 8WH9 plugs 1) 1) Also available as a PE version More technical

More information

22 & 30mm Push Buttons, Selector Switches & LED Pilot Lights

22 & 30mm Push Buttons, Selector Switches & LED Pilot Lights 22 & 30mm Push Buttons, Selector Switches & LED Pilot Lights 22mm 22mm Non Illuminated Metal Operators Altech orp. can provide other push button and actuator options. If your requirement calls for a 22

More information

Allen-Bradley PLCs. 100 Programmable Controller Processor Unit -Catalog Nos LPI01, -LP102, -LP103, -LP104 SLC TM. The Unit

Allen-Bradley PLCs. 100 Programmable Controller Processor Unit -Catalog Nos LPI01, -LP102, -LP103, -LP104 SLC TM. The Unit PRODUCT DATA SLC TM 100 Programmable Controller Processor Unit -Catalog Nos. 1745-LPI01, -LP102, -LP103, -LP104 The SLC 100 programmab/e Contro"er The SLC 100 Programmable Controller is easy to program,

More information

Power Sensing Products

Power Sensing Products Our power monitoring sensors measure loads and improve performance by providing instantaneous True Power kw or accumulated kwh data. They are simple, reliable and accurate. Digital communications are available

More information

PENDANT PUSHBUTTON STATIONS

PENDANT PUSHBUTTON STATIONS SBP2 PENDANT PUSH STATIONS SBP2 PENDANT PUSH STATIONS THE LIGHTWEIGHT PENDANT STATION FOR HEAVYWEIGHT APPLICATIONS COMPLETE PENDANT STATIONS 2, 4, 6, 8, 10, or 12 button configurations 1, 2, or 3 speed

More information

Ice Cube Relays. R2/R4 Plug-in Power Relays... G58 Technical Information... G63. R15 Plug-in Power Relays... G68 Technical Information...

Ice Cube Relays. R2/R4 Plug-in Power Relays... G58 Technical Information... G63. R15 Plug-in Power Relays... G68 Technical Information... Ice Cube Relays R2/R4 Plug-in Power Relays... 58 Technical Information... 63 R15 Plug-in Power Relays... 68 Technical Information... 72 RUC Plug-in Power Relays... 76 Technical Information... 79 RY2 Plug-in

More information

Click 'n' Go: SIRIUS Modular System SIRIUS. Highly flexible system-based switching, protecting and starting. Answers for industry.

Click 'n' Go: SIRIUS Modular System SIRIUS. Highly flexible system-based switching, protecting and starting. Answers for industry. Click 'n' Go: SIRIUS Modular System SIRIUS Highly flexible system-based switching, protecting and starting. Answers for industry. s Everything for the electrical cabinet: SIRIUS Modular System. Contents

More information

XT IEC Power Control Contactors, Starters and Overload Relays

XT IEC Power Control Contactors, Starters and Overload Relays May 00 Product Family Overview 9 Contents Features and Benefits Description Page Contactors and Starters Catalog Number Selection................. Non-reversing Contactors.... Reversing Contactors........

More information

Dart Digital Controls

Dart Digital Controls YOUR MOTION SYSTEMS SOLUTIONS PROVIDER Dart Digital ontrols Introducing New Features for Added System Flexibility Universal Power Supply Adjustable Set Rate Front Panel Programming Easy Terminal Access

More information

920 Remote Control (RC) Switches

920 Remote Control (RC) Switches 920 Remote Control (RC) Switches ASCO is the global leader in power switching and controls ASCO 920 PRODUCT SPECIFICATIONS SWITCH ONLY (PANELBOARD MOUNTING) 1,2,3 () DIMENSIONS, IN.(MM) WIDTH HEIGHT DEPTH

More information

Load Feeders and Motor Starters for Use in the Control Cabinet

Load Feeders and Motor Starters for Use in the Control Cabinet Load Feeders and Motor Starters for Use in the Control Cabinet Price groups 12W, 14O, 230, 241, 250, 260, 41B, 41D, 41E, 41L, 42C, 42D, 42F, 471, 4N1, 5K1, 5K2, 5N2, 764, 15, 16 /2 Introduction SIRIUS

More information

Sentron 3VT circuit breakers Simply Smart: First choice for power distribution

Sentron 3VT circuit breakers Simply Smart: First choice for power distribution s Sentron 3VT circuit breakers Simply Smart: First choice for power distribution www.siemens.com/industry Sentron 3VT Molded Case Circuit-Breakers - 10-1600Amperes With the standard line of 3VT molded-case

More information

CurrentWatch Current Sensors. EGF Series Ground Fault Sensors. Ground Fault Sensors with Solid-State or Mechanical Relay Outputs.

CurrentWatch Current Sensors. EGF Series Ground Fault Sensors. Ground Fault Sensors with Solid-State or Mechanical Relay Outputs. CurrentWatch Current Sensors Ground Fault Sensors with Solid-State or Mechanical Relay s 1 Contents Overview.................... 1 Model Selection, Switches...... 2 Model Selection, Accessories... 3 Wiring

More information

194E FA 32 E P11 P11 6

194E FA 32 E P11 P11 6 Bulletin E IEC Load Switches, A Product Selection/Catalog Number Explanation Bulletin E Enclosed Disconnect Load Switches with R Handles (with Defeater, suitable for padlocks) E-FA Painted Steel Enclosure

More information

Solid-State Contactors

Solid-State Contactors Solid-state contactors for switching motors The solid-state contactors for switching motors are intended for frequently switching on and off three-phase current operating mechanisms up to 7.5 kw and reversing

More information

Bulletin 700-HL 2-Pole Terminal Block Relay

Bulletin 700-HL 2-Pole Terminal Block Relay Bulletin 700-HL 2-Pole Terminal Block Relay Bulletin 700-HL 2-Pole "Terminal Block Relay" Relay and socket assembled interface modules for high density interposing or isolation applications Screw terminal

More information

Allen-Bradley Bulletin 100 Contactors

Allen-Bradley Bulletin 100 Contactors Allen-Bradley Bulletin 100 Contactors An integrated portfolio of IEC Contactors that save panel-space and energy Features and Benefits: Direct-on-line and reversing contactors Built-in surge suppression

More information

International, LLC. 22mm Push Buttons & Operator Interface - PB(M)22. Features

International, LLC. 22mm Push Buttons & Operator Interface - PB(M)22. Features International, Features Available in die cast chrome plated and double insulated head Wide varity of operators available Double break, slow action, self-clean contacts Positive opening of normal close

More information

60103 Circuit Breaker

60103 Circuit Breaker 6003 Circuit Breaker United States MINIATURE CIRCUIT BREAKER, 20/240VAC, 2A, CIRCUIT BREAKER TYPE: STANDARD Image not available Product Information Features and Specifications Circuit Breaker Type: Standard

More information

Connectivity Solutions

Connectivity Solutions SmartWire-DT.1 System Overview Product Description.................................... Features............................................. System Overview Diagram............................... System

More information

SIEMENS HEALTHCARE INTEGRATED ELECTRICAL CABINET

SIEMENS HEALTHCARE INTEGRATED ELECTRICAL CABINET Product Data Sheet Technical Publications SIEMENS HEALTHCARE INTEGRATED ELECTRICAL CABINET for ARTIS Q / Q.ZEN / ZEE BIPLANE IECAX480V225A Main Disconnect Panel Bevco Engineering Company, Inc. CONFIDENTIAL

More information

Operating Instructions. For. Level Control Module. Model SSR 1000

Operating Instructions. For. Level Control Module. Model SSR 1000 Operating Instructions For Level Control Module Model SSR 1000 SSR Operation Instructions Rev. 1 Jan 01 Page 1/7 1. Note Please read and take note of these operating instructions before unpacking and commissioning.

More information

194E FA 32 E P11 P11 6

194E FA 32 E P11 P11 6 Bulletin E IEC Load Switches, A Product Selection/Catalog Number Explanation Bulletin E Enclosed Disconnect Load Switches with R Handles (with Defeater, suitable f padlocks) E-FA Painted Steel Enclosure

More information

Connectivity Solutions

Connectivity Solutions SmartWire-DT.1 System Overview Product Description.................................... Features............................................. System Overview Diagram............................... System

More information

Table of Specifications

Table of Specifications Table of Specifications Midi-Contactors 3-Pole Magnetic Contactors Terminal type CC9 CC12 CC18 CC22 CC32 CC40 Screw Only Screw Only GUA1, GUA2, GUA4 GUA-1 GUA-2, GUA-4 GUA-1 GUA-2, GUA-4 GT Type Thermal

More information

General Purpose Control Components Welcome to the Control Catalog!

General Purpose Control Components Welcome to the Control Catalog! Welcome to the Control Catalog! This new edition is your comprehensive guide to product selection and pricing for GE electrical control products. Our new format in this latest edition allows for maximum

More information

Push buttons and selectors

Push buttons and selectors Accessories and spare parts 8 LM2T A130 8 LM2T A140 8 LM2T A185 8 LM2T AL... Order code Description Qty per Wt 8 LM2T A12❶ Coloured diffuser for 10 0.001 double touch buttons 8 LM2T A130 Threaded plug

More information

4 Channel 4-20mA/0-10V Industrial Media Converter

4 Channel 4-20mA/0-10V Industrial Media Converter USER GUIDE RLH Industries, Inc. The leader in rugged fiber optic technology. U5 08A00 hannel 0mA/00V Industrial Media onverter SYSTEM INSTALLATION INFORMATION Description This Fiber Optic Media converter

More information

dual-line 6-dIGIt process MeteR

dual-line 6-dIGIt process MeteR dual-line 6-dIGIt process MeteR ProVu Se r i e S provu Model pd6000 0-20 ma, 4-20 ma, 0-5 V, 1-5 V, and ±10 V Inputs NEMA 4X, IP65 Front Universal 85-265 VAC or 12/24 VDC Input Power Large Dual-Line 6-Digit

More information

TECHNICAL BROCHURE BCPNEMAST R0. NEMA Rated Three-Phase Starters BY EATON

TECHNICAL BROCHURE BCPNEMAST R0. NEMA Rated Three-Phase Starters BY EATON TECHNICAL BROCHURE BCPNEMAST R0 NEMA Rated Three-Phase Starters BY EATON STANDARD FEATURES Series ECN - NEMA Rated Three-Phase Starters Adjustable Electronic Overloads C440 Series - Adjustable Class, Bi-metallic,

More information

Terminal Equipment Controller Enclosure

Terminal Equipment Controller Enclosure Document No. 550-196 Terminal Equipment Controller Enclosure Product Description A Terminal Equipment Controller enclosure is a general-purpose metal cabinet with a removable cover that houses an electronic

More information

MSR Level Control Relay Module Operating Instructions for Level Control Relay Module Model: MSR

MSR Level Control Relay Module Operating Instructions for Level Control Relay Module Model: MSR Operating Instructions for Level Control Relay Module Model: MSR MSR Operation Instructions Rev. Apr 07 Page 1/8 1. Note Please read and take note of these operating instructions before unpacking and commissioning.

More information

Connectivity Solutions. For Immediate Delivery or Tech Support call KMParts.com at (866) Contents.

Connectivity Solutions. For Immediate Delivery or Tech Support call KMParts.com at (866) Contents. .1 Connectivity Solutions Contents Description System Components.................... Contactor Modules..................... Pilot Device Modules.................... Technical Data and Specifications..........

More information

ALLEN BRADLEY RELAY Bulletin 700-HF

ALLEN BRADLEY RELAY Bulletin 700-HF ALLEN BRADLEY RELAY Bulletin 700-HF Contact Rating DPDT, 3PDT, 4PDT Plug-in Quick Connect Solder Terminals Options: LED, Push-to-Test Operator DEMENSIONS: Bulletin 700-HF Relay (DPDT) Bulletin 700-HF (3PDT)

More information

EH175 SA F 1-1 C 4 L A

EH175 SA F 1-1 C 4 L A Reduced voltage starters Open & enclosed Description Compact, space saving design 16 starter frame sizes, B16 to EH00 Maximum U.L. horsepower ratings Mechanically interlocking as standard for wye-delta

More information

Powermite 599 MT Series SAS Electronic Valve Actuator 24 Vac or 24 Vdc, Proportional Control

Powermite 599 MT Series SAS Electronic Valve Actuator 24 Vac or 24 Vdc, Proportional Control Powermite 599 MT Series SAS Electronic Valve Actuator 24 Vac or 24 Vdc, Proportional Control Description Features Application The Powermite 599 MT Series SAS Electronic Valve Actuator requires a 24 Vac

More information

Motor Controllers AC Semiconductor Motor Controller Type RSHR MIDI

Motor Controllers AC Semiconductor Motor Controller Type RSHR MIDI otor Controllers AC Semiconductor otor Controller Type RSHR IDI Soft starting and stopping of 3-phase induction squirrel cage motors 2-phase control with integral bypassing of semiconductors Low inrush

More information

Carbon Monoxide (CO) Gas Detection and Control System

Carbon Monoxide (CO) Gas Detection and Control System Carbon Monoxide (CO) Gas Detection and Control System DESCRIPTION Gas monitor with built-in carbon monoxide (CO) sensor, wall-mounted, accepts inputs from remote devices such as other gas sensors, temperature

More information

EZ-ZONE. EZ-ZONE ST Integrated Control Loop Makes Solving the Thermal Requirements of Your System Easy

EZ-ZONE. EZ-ZONE ST Integrated Control Loop Makes Solving the Thermal Requirements of Your System Easy EZ-ZONE ST EZ-ZONE ST Integrated Control Loop Makes Solving the Thermal Requirements of Your System Easy The new EZ-ZONE ST integrated control loop solid state controller from Watlow offers complete thermal

More information