1 S O/JUL 2002 File: SERVICE MANUAL - SECTION 90 Replaces: S O/APR-2001 Dist: 3, 3a, 3b, 3c OPERATION FRICK QUANTUM ACUair CONTROL PANEL Version 2.1x
2 S O FRICK QUANTUM ACUair CONTROL PANEL Page 2 OPERATION Table of Contents OVERVIEW OF OPERATOR INTERFACE... 3 GRAPHIC SCREENS ALARMS/SHUTDOWNS MESSAGES INDEX... 31
3 FRICK QUANTUM ACUair CONTROL PANEL S O OPERATION Page 3! Warning The Quantum has the capability of being modified by the user/owner in order to obtain different performance characteristics. Any modification to the standard default settings may have a severe negative impact on the operation and performance of the equipment. Any modification to these control settings is the sole responsibility of the user/owner and Frick disclaims any liability for the consequences of these modifications. It is possible that the modification of these settings may cause improper operation and performance that results in property damage, personal injury or death. It is the responsibility of the user/owner to evaluate and assess the consequences of their actions prior to modifying the controls for this unit. OVERVIEW OF OPERATOR INTERFACE OPERATOR ACCESS
4 S O FRICK QUANTUM ACUair CONTROL PANEL Page 4 OPERATION KEYS AND KEY FUNCTIONS KEYPAD KEYS [HOME] [MENU] [HELP] [F1] [F2] [0][9] [.] [+/-] [ENTER] [PREVIOUS SCREEN] [DELETE] [] [] [] []
5 FRICK QUANTUM ACUair CONTROL PANEL S O OPERATION Page 5 SCREEN KEYS [Change Setpoints] [OK] [CANCEL] - [Increase Value] - [Decrease Value] - [Up One] [Down One] [Page Up] [Page Down] [Goto Start] [Goto End] [More ] [ Back] [Enable] [Disable] TO CHANGE SETPOINTS The Quantum has the capability of being modified by the user/owner in order to obtain different performance characteristics. Any modification to the standard default settings may have a severe negative impact on the operation and performance of the equipment. Any modification to these control settings is the sole responsibility of the user/owner and Frick disclaims any liability for the consequences of these modifications. It is possible that the modification of these settings will cause improper operation and performance that results in property damage, personal injury or death. It is the responsibility of the user/owner to evaluate and assess the consequences of their actions prior to modifying the controls for this unit. NOTE:! Warning the [Change Setpoints] [DELETE] [ENTER] [OK] 7. [OK] [CANCEL]
6 S O FRICK QUANTUM ACUair CONTROL PANEL Page 6 OPERATION INITIAL SETUP PROCEDURE GRAPHIC SCREENS AIR HANDLING UNIT OVERVIEW SCREEN
7 FRICK QUANTUM ACUair CONTROL PANEL S O OPERATION Page 7 AIR HANDLING UNIT OVERVIEW SCREEN SCREEN KEY SET [Login to Unit] [Panel Setup] [Security] [Panel Status]
8 S O FRICK QUANTUM ACUair CONTROL PANEL Page 8 OPERATION UNIT SELECTED - "OPERATING STATUS" SCREEN AIR HANDLING UNIT DATA BOX: Status Off Running Starting Mode Process Cleanup ALARM STATUS BOX: ALARM SHUTDOWN [Alarms/Shutdown] [Alarms/Shutdown] DEMAND OUTPUT BOX:
9 ANALOG READINGS BOX: Screen Title FRICK QUANTUM ACUair CONTROL PANEL S O OPERATION Page 9 OPERATOR SELECTION KEYS [Menu] [Unit Mode] UNIT SELECTED - "OPERATING STATUS - 2" SCREEN [Remote] [Mode] [Run] [Stop] [Operating Status Page 2] Operator Selection Keys Date and Time Unit Name Sensor ACUair INPUT STATUS BOX: On Off Air Flow Switch Remote Process/Cleanup Remote Start/Stop Burner Status Flame Failure Demand Defrost Smoke/Ammonia Burner Status (Aux. 2) ACUair OUTPUT STATUS BOX: On Off
10 Supply Fan Motor Exhaust Fan #1 Exhaust Fan #2 Burner Command Cooling Stage #1 Cooling Stage #2 Cooling Stage #3 Cooling Stage #4 Preheat Command FRICK QUANTUM ACUair CONTROL PANEL S O OPERATION Page 10 Suction Hot Gas Bleed Aux. Output #7 Aux. Output #8 SENSOR INDICATION: DEFROST STATUS BOX: UNIT SELECTED - "MAIN MENU" SCREEN SCREEN KEY SET [Operating Status] [Alarms/Shutdowns] [Clear Alarms] [Control Setup] [Cooling Control] [Heating Control] [Preheat Control] [Exhaust Control] [Damper Control] [Humidity Control] [Safety Setpoints] [Defrost] [Variable Fan] [Analog Aux. Input] [Analog Aux. Output] [Calibration]
11 FRICK QUANTUM ACUair CONTROL PANEL S O OPERATION Page 11 MAIN MENU SELECTION - "ALARMS/SHUTDOWNS" SCREEN [Clear Alarms] [Alarms/Shutdown History] [Clear Alarms] MAIN MENU SELECTION - "ALARMS/SHUTDOWNS HISTORY" SCREEN
12 S O FRICK QUANTUM ACUair CONTROL PANEL Page 12 OPERATION MAIN MENU SELECTION - "CONTROL SETUP" (1) SCREEN [OK] Process Control Setpoint Process Cooling Lockout Minimum Outside Air Cleanup Cooling Temperature Cleanup Heating Temperature Cleanup Cooling Lockout Cleanup Heating Lockout
13 FRICK QUANTUM ACUair CONTROL PANEL S O OPERATION Page 13 MAIN MENU SELECTION - "CONTROL SETUP" (2) SCREEN [OK] Process Control Setpoint Cleanup Heating Setpoint [Cooling Control Setup] [Heating Control Setup] [Preheat Control Setup] [Exhaust Control Setup] [Damper Control Setup] [Humidity Control] [Safety Setpoints] [Defrost Control] [Var. Fan Control] [Analog Aux. Input] [Analog Aux. Output]
14 S O FRICK QUANTUM ACUair CONTROL PANEL Page 14 OPERATION CONTROL SETUP - COOLING CONTROL SETUP SCREEN
15 FRICK QUANTUM ACUair CONTROL PANEL S O OPERATION Page 15 CONTROL SETUP - "HEATING CONTROL SETUP" SCREEN
16 S O FRICK QUANTUM ACUair CONTROL PANEL Page 16 OPERATION CONTROL SETUP - EXHAUST CONTROL SETUP SCREEN Outside Air Damper Position Exhaust Demand Values Stage #1 Stage #2
17 FRICK QUANTUM ACUair CONTROL PANEL S O OPERATION Page 17 CONTROL SETUP - DAMPER CONTROL SETPOINT SCREEN
18 S O FRICK QUANTUM ACUair CONTROL PANEL Page 18 OPERATION CONTROL SETUP - HEAT PROFILE CONTROL SCREEN CONTROL SETUP - SAFETY SETPOINTS SCREEN No Air Flow Shutdown Delay Ammonia Alarm Ammonia Alarm Delay Ammonia Shutdown Ammonia Shutdown Delay Discharge Air Alarm Discharge Air Alarm Delay Discharge Air Shutdown Discharge Air Alarm Delay Aux. 1 Delay Aux. 2 Delay
19 FRICK QUANTUM ACUair CONTROL PANEL S O OPERATION Page 19 ANALOG CALIBRATION - "MAIN MENU" SCREEN!!! Warning Entering Calibration Screens!!! ANALOG CALIBRATION - "ANALOG CALIBRATION" SCREEN
20 S O FRICK QUANTUM ACUair CONTROL PANEL Page 20 OPERATION ANALOG CALIBRATION - "PRESSURE CALIBRATION" SCREEN.
21 FRICK QUANTUM ACUair CONTROL PANEL S O OPERATION Page 21 ANALOG CALIBRATION - "TEMPERATURE CALIBRATION" SCREEN [Calibration Setpoints]
22 S O FRICK QUANTUM ACUair CONTROL PANEL Page 22 OPERATION ANALOG CALIBRATION - "OTHER CALIBRATION" SCREEN [Calibration Setpoints]
23 FRICK QUANTUM ACUair CONTROL PANEL S O OPERATION Page 23 PANEL SETUP - PANEL SETUP SCREEN [Set Time] [Increase Minutes] [Increase Hours] [Increase Day] [Increase Month] [Increase Year] [Decrease Year] [Change Degrees] : [Change to Fahrenheit] [Change to Celsius] [Change Comms] [Change Setpoints] [Change to Baud] [Select Options] [Flash Screen on Shutdown] [Remote Control Mode Available] "Screen Setup" SCREEN
24 S O FRICK QUANTUM ACUair CONTROL PANEL Page 24 OPERATION PANEL SETUP - PANEL SETUP SCREEN [Standard Screen] [Mono Screen] [Blue Screen] [Lighten] [Darken] [Disable] [Enable] [Change Setpoints]
25 FRICK QUANTUM ACUair CONTROL PANEL S O OPERATION Page 25 "SECURITY SETUP" SCREEN [Change Setpoints] Full access Moderate access No access [Change Full Access] [Change Moderate Access] [No Access]
26 S O FRICK QUANTUM ACUair CONTROL PANEL Page 26 OPERATION PANEL STATUS - "REAL TIME TRENDING" SCREEN Real time recording interval [Data Log View] [Trending View]
27 FRICK QUANTUM ACUair CONTROL PANEL S O OPERATION Page 27 PANEL STATUS - "REAL TIME TRENDING" SCREEN DATA LOG VIEW [Goto Start] [Page Down] [Page up] [Goto End] [Select Data]
28 S O FRICK QUANTUM ACUair CONTROL PANEL Page 28 OPERATION PANEL STATUS - "REAL TIME TRENDING" SCREEN TRENDING VIEW [Select Data]
29 FRICK QUANTUM ACUair CONTROL PANEL S O OPERATION Page 29 PANEL STATUS - "HISTORY TRENDING" SCREEN History recording interval [Data Log View] [Trending View]
30 S O FRICK QUANTUM ACUair CONTROL PANEL Page 30 OPERATION Alarms/Shutdowns Messages
31 FRICK QUANTUM ACUair CONTROL PANEL S O OPERATION Page 31 INDEX A B C D E F
32 S O FRICK QUANTUM ACUair CONTROL PANEL Page 32 OPERATION G H I K L M N O P Q R S
33 FRICK QUANTUM ACUair CONTROL PANEL S O OPERATION Page 33 T U W
34 S O FRICK QUANTUM ACUair CONTROL PANEL Page 34 OPERATION
35 FRICK QUANTUM ACUair CONTROL PANEL S O OPERATION Page 35
36 S O FRICK QUANTUM ACUair CONTROL PANEL Page 36 OPERATION Printed in U.S.A. Subject To Change Without Notice
FRICK QUANTUM LX AcuAir CONTROL PANEL
Form 090.510-O (SEPTEMBER 2013) File: SERVICE MANUAL - Section 90 Replaces: 090.512-O (DECEMBER 2012) Dist: 3, 3a, 3b, 3c FRICK QUANTUM LX AcuAir CONTROL PANEL Version 3.2x 090.510-O (SEPTEMBER 13) Page
More informationFRICK QUANTUM ACUair CONTROL PANEL VERSION 2.1x
S90-500 M/JULY 2002 File: SERVICE MANUAL - SECTION 90 Replaces: NOTHING (New Information) Dist: 3, 3a, 3b, 3c FRICK QUANTUM ACUair CONTROL PANEL VERSION 2.1x S90-500 M FRICK QUANTUM ACUair CONTROL PANEL
More informationFRICK QUANTUM HD UNITY SYSTEM CONTROLLER
Form 090.670-O (AUG 2015) OPERATION File: SERVICE MANUAL - Section 90 Replaces: NOTHING Dist: 3, 3a, 3b, 3c OPERATION FRICK QUANTUM HD UNITY SYSTEM CONTROLLER ENGINE ROOM CONDENSER VESSEL EVAPORATOR Version
More informationExactLogic BACnet Communicating Pressure Dependent VAV Damper Control with Heat EXL01820 Sequence Datasheet
ExactLogic BACnet Communicating Pressure Dependent VAV Damper Control with Heat EXL01820 Sequence Datasheet DataSheet ev 1.12.307/4.0 June 14, 2018 Operating Sequence Standard Occupied During normal occupied
More informationFRICK QUANTUM LX AcuAir CONTROL PANEL
Form COMUNICATIONS SETUP File: SERVICE MANUAL - Section 90 Replaces: 090.510-CS (OCT 2010) Dist: 3, 3a, 3b, 3c FRICK QUANTUM LX AcuAir CONTROL PANEL Version 3.2x Page 2 TABLE OF CONTENTS SECTION 1 INTRODUCTION
More informationFRICK QUANTUM LX CONDENSER/VESSEL CONTROL PANEL
Form File: SERVICE MANUAL - Section 90 Replaces: 090.560-O (APR 2015) Dist: 3, 3a, 3b, 3c FRICK QUANTUM LX CONDENSER/VESSEL CONTROL PANEL Version 3.0x Please check www.johnsoncontrols.com/frick for the
More informationPoolPak MPK with CommandPak Control System CPCS BACnet /IP User s Guide DOCUMENT #: SVW07-MPKBACNIP
PoolPak MPK with CommandPak Control System CPCS BACnet /IP User s Guide DOCUMENT #: SVW07-MPKBACNIP-20171020 UPDATED: OCTOBER 2017 INTRODUCTION PoolPak dehumidifiers equipped with an CommandPak Control
More informationQuick Start Guide DDC (2014/02) Subject to change without prior notice Quick Start Guide
Quick Start Guide 560/583 DDC 8733914716(2014/02) Please refer to the included Hardware User s Guide and BACview Installation and Operation Manual for more detailed information on setting up and using
More informationBACnet MS/TP Interface User s Guide
PoolPak MPK with CommandPak Control System CPCS BACnet MS/TP Interface User s Guide DOCUMENT #: SVW07-BACNET-MSTP-20171020 UPDATED: OCTOBER 2017 INTRODUCTION PoolPak dehumidifiers equipped with an CommandPak
More informationCommandCenter Operator Panel
CommandCenter Operator Panel Introduction This document describes the different features of the Operator Panel (local or remote) that is used with the Seresco units. Startup Screens When the unit start
More informationExactLogic BACnet Communicating Zone Damper EXL01710 Sequence Datasheet
ExactLogic BACnet Communicating Zone Damper EXL01710 Sequence Datasheet DataSheet ev 1.12.302/4.3 October 27, 2014 Operating Sequence Standard Occupied During normal occupied operation the display will
More informationQuantum HD Release Notes
Quantum HD Release Notes OS Version 10.17 Released 7-14-2014 To upgrade to OS version 10.17 directly the current OS version must be 10.13 through 10.16. To check the current OS version on the Quantum HD
More informationCONTROLS. Quantum HD. Heavy Duty Performance In High Definition
CONTROLS Quantum HD Heavy Duty Performance In High Definition CONTROLS Quantum HD Industrial Refrigeration Controller Quantum HD with Unity Architecture Quantum HD control panels make equipment management
More informationDryer. M720 Programming and Operation Manual. July 15, 2015 Revision 1.51
Dryer M720 Programming and Operation Manual July 15, 2015 Revision 1.51 Contents 1 Important Safety Information 1 1.1 FOR YOUR SAFETY - CAUTION!............................. 1 2 Control Overview 2 2.1
More informationExactLogic BACnet Communicating Thermostat EXL01816 Sequence Datasheet
ExactLogic BACnet Communicating Thermostat EXL01816 Sequence Datasheet DataSheet ev 1.12.307/4.0 Jun 20, 2018 Operating Sequence Standard Occupied During normal occupied operation the display will show
More informationHigh Motor Current Shutdown High Motor Current Warning Low Motor Current Shutdown Compressor Auxiliary Shutdown
Important: To upgrade from Quantum HD version 10.21 or earlier to Quantum HD Unity version 10.30 or later requires the flashcard to be changed. These are available through the Baltimore Parts Center, part
More informationINSTALLATION INSTRUCTIONS MBPEFY Series Mixing Box for Mitsubishi PEFY Series Units. Before Starting Installation Warning. Installation Instructions
Before Starting Installation Warning Shut power to unit prior to any work being done. Personal injury or death could result. Only qualified HVAC service personnel should install, troubleshoot, repair or
More informationFRICK QUANTUM COMPRESSOR CONTROL PANEL
S90-010 CS/APR 2004 File: SERVICE MANUAL - SECTION 90 Replaces: S90-010 CS/APR 02 Dist: 3, 3a, 3b, 3c FRICK QUANTUM COMPRESSOR CONTROL PANEL VERSION 5.0x S90-010 CS FRICK QUANTUM COMPRESSOR CONTROL PANEL
More informationDescription. descriptors, makes set-up and monitoring very user friendly.
Description The Meridian CV & CV-EX Control Systems are designed as an alternative to multiple programmable thermostats or expensive building automation systems in facilities that have unitary type, HVAC
More informationBrivis Programmable Controller OWNER S MANUAL
Brivis Programmable Controller OWNER S MANUAL Brivis Ducted Inverter Programmable Controller Brivis Part No:B026001 Brivis Climate Systems Pty Ltd Tel:1300 BRIVIS brivis.com.au Thank you very much f purchasing
More informationQuick Start Guide. Variable Speed Drive. Part Number: Issue: 3
EVC Series Quick Start Guide English Issue 3.book Page 1 Friday, March 11, 2016 1:38 PM Quick Start Guide Variable Speed Drive Part Number: 0478-0335-03 Issue: 3 Original Instructions For the purposes
More informationControl panel GEA Omni. Instruction Manual E_806550_2
GEA Omni Instruction Manual E_806550_2 COPYRIGHT All Rights reserved. No part of this publication may be copied or published by means of printing, photocopying, microfilm or otherwise without prior written
More informationSCC Inc. LMV5 Series. Installation Instructions. Document No. LV February 12, 2018
Installation Instructions February 12, 2018 OCI415.30 for use with LMV5... Linkageless Burner Management Systems OCI415.30 Description The OCI415.30 provides the LMV5... family of flame controllers with
More informationWavePRO Wireless Programmable T2500 Thermostat & R2500 Receiver OPERATING MANUAL. Model K
WavePRO Wireless Programmable T2500 Thermostat & R2500 Receiver OPERATING MANUAL Model K2500-001 1 THE PECO WAVEPRO WIRELESS SYSTEM Thank you for choosing the PECO WavePRO TM Wireless System (Model K2500-001).
More information4-step Chiller and Heat Pump Controller
4-step Chiller and Heat Pump Controller Technical Data Sheet GENERAL DESCRIPTION MODELS CODE MODEL DESCRIPTION MW324000 ECH 420 HEAT PUMP WITH 4 STEPS/ 2 CIRCUITS + MODBUS MW324005 ECH 420/V WITH SCREW
More informationRTD-NET Installation Instructions
LED3 SW1 LED4 RTD-NET Installation Instructions 0V +V POWER 15-24VDC English RTD-NET Installation Instructions 100.00 RTD-NET Control Interface realtime Control Systems REMC P1 P2 RS485 D-BUS DB DA GND
More informationPanda xcontrol Manual
Manual Panda_xControl_eng.R02 29.9.16 Current revision status Current: Replaces: Document Panda_xControl_eng.R02_29.9.16 Panda_xControl_eng.R01.5 Revision Manual compiled on the basis of deu R02 Page Created
More informationCustom Controller Installation Instructions
MODEL CUSTOM CONTROLLER HARDWARE CODE MAX ALLOWABLE AMBIENT TEMP: 70 C (158 F) THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES. OPERATION IS SUBJECT TO THE FOLLOWING TWO CONDITIONS: 1) THIS DEVICE MAY
More informationIntroduction. To use Carrier wireless sensors, you must have: A i-vu v6.5 or later system v6-00 or later drivers
Wireless Sensor CARRIER CORPORATION 2017 A member of the United Technologies Corporation family Stock symbol UTX Catalog No. 11-808-583-01 6/2/2017 Verify that you have the most current version of this
More informationExactLogic BACnet Communicating Thermostat EXL01716 Sequence Datasheet Duel Deck VAV
ExactLogic BACnet Communicating Thermostat EXL01716 Sequence Datasheet Duel Deck VAV DataSheet ev 1.12.302/4.1 June 26, 2018 Operating Sequence Standard Occupied Thermostat occupancy can be set from a
More informationW8735A1013 EnviraCOM Serial Adapter
W8735A1013 EnviraCOM Serial Adapter INSTALLATION INSTRUCTIONS TABLE OF CONTENTS INSTALLATION... 2 When installing this product... 2 Selecting Location... 2 Mounting W8735A1013 EnviraCOM Serial Adapter...
More informationOM Operation and Maintenance Manual. Intelligent Equipment for Daikin Applied Trailblazer Air-cooled Scroll Chiller. Models: AGZ-D and AGZ-E
Operation and Maintenance Manual Intelligent Equipment for Daikin Applied Trailblazer Air-cooled Scroll Chiller OM 1241 Group: Controls Part Number: 910166134 Date: June 2015 Models: AGZ-D and AGZ-E Table
More informationUser s Guide TG Series C. Senva Sensors 9290 SW Nimbus Ave Beaverton, OR 97008
User s Guide TG Series Senva Sensors 9290 SW Nimbus Ave Beaverton, OR 97008 154-0031-0C Rev. Release Date By Description of Change ECR 0A 4/14/2016 CKB Initial Release --- 0B 3/7/2017 CKB Updated for RS485
More informationBACVIEW MANUAL Software Version 3.06 INSTALLATION AND OPERATION MANUAL
BACVIEW MANUAL Software Version 3.06 INSTALLATION AND OPERATION MANUAL 641-K31 1 BACVIEW INSTALLATION AND OPERATION IMPORTANT: This manual is for use with controller ZONE I/O 560 FHP part number 641-224
More informationDual Digital Module Technical Guide
Factory Packaged Controls Coil Products Dual Digital Module Table of Contents OVERVIEW... 3 INSTALLATION AND WIRING... 4 Environmental Requirements...4 Mounting...4 Power Supply and Communications...4
More informationSystem Controls Suggested Specification
1. Description A. Rooftop Unit Controller The Rooftop Unit Controller shall come equipped with a proportional-integral (PI) controller for accurate temperature control. The rooftop unit controller shall
More informationPF3100 Quick User Guide R 0.3 PROFIRE PF3100. Quick User Guide. PROFIRE Page 1 of 13
R 0.3 PF3100 Quick User Guide solutions@profireenergy.com Page 1 of 13 1. System Overview... 3 2. General Information... 3 Status LED... 3 3. Interpreting System Information... 4 Alerts Tab... 4 4. Running
More informationDUKE UNIVERSITY DESIGN & CONSTRUCTION STANDARDS
1 25 95 00 Integrated Automation Control Sequences for HVAC GENERAL The HVAC operational sequences in this guideline are commonly used by Duke University. They are being provided as a preferred design
More informationFX 2 Instruction Manual
FX 2 Instruction Manual Climma Compact Version Annapolis MD USA 301 352 6962 info@veco-na.com Introduction: The FX2-DX digital controller operates onboard air conditioning equipment to provide room temperature
More informationQuantum HD Unity Software Update Procedure
Quantum HD Unity Software Update Procedure Read Thoroughly Updating the Operating Software on a Quantum HD Unity is easy and free. Use the following steps to download the update and upload it to your Quantum
More informationSetpoint Limits. Setpoint Limits products.koer.com Page 1 of 7
2017 products.koer.com Page 1 of 7 INTRODUCTION Learn how to change between which user can change the desired Setpoint 2017 products.koer.com Page 2 of 7 Step 1 Enter Advanded Menu ONLY AUTHORIZED MAINTENANCE
More informationAthena Series RMC Hot Runner Controller Configuration and Operation Manual
Athena Series RMC Hot Runner Controller Configuration and Operation Manual Athena and CompuStep are registered trademarks, and Multi-Comm and SafeChange are trademarks of Athena Controls, Inc. MODBUS is
More informationPF2100 MODBUS LOGGER CARD SYSTEM SPECIFICATION. v1.0 DRAFT Revised Dec 4, 2014 Last Revised by Alex Messner
PF2100 MODBUS LOGGER CARD SYSTEM SPECIFICATION Revised Last Revised by Alex Messner This page was intentionally left blank. Table of Contents 1 Overview... 2 2 User Interface... 3 2.1 LEDs... 3 2.2 Buttons...
More informationpco 3 Controller User Manual ASPX Digital Scroll, Air Packaged Chiller For Version MCDSV_A02
pco 3 Controller User Manual ASPX Digital Scroll, Air Packaged Chiller For Version MCDSV_A02 pco 3 Controller User Manual Introduction The Airstack Chiller is a modular air-cooled chiller composed of
More informationEarthLinked Diagnostic and Monitoring system (EDM) Installation and Operations Manual
EarthLinked Diagnostic and Monitoring system (EDM) Installation and Operations Manual EDM-IOM (03/16) 2016 EarthLinked Technologies, Inc. Disclaimer Proper installation and servicing of this EarthLinked
More informationInstruction Manual CTC-1
Troubleshooting & Specs CTC-1 Amps / Volts requirements Min / Max operating temperature Min / Max operating Humidity Temperature Measurement range Temperature Accuracy CO2 sensor type CO2 Measurement range
More informationINSTRUCTIONS FOR USING THE CONTROL PANEL
DIGIT SED ELECTRONIC CONTROLLER WITH LCD DISPLAY 1.09.370E 10.01.2007 VALLOX These instructions replace and complement the instructions for use and maintenance of the following VALLOX units: VALLOX DIGIT
More informationCommunication Register Map - Uniflair Cooling
DIGITAL 0 1 1 - - - - DIGITAL 1 2 2 System On (Fan) 0 or 1 boolean R DIGITAL 2 3 3 Compressor 1 0 or 1 boolean R DIGITAL 3 4 4 Compressor 2 0 or 1 boolean R DIGITAL 4 5 5 Compressor 3 0 or 1 boolean R
More informationSCC Inc. TS Series TS MS Master Panels for Boiler Management, Lead/Lag, and Building Management System Interface. Installation Instructions
SCC Inc. TS MS Master Panels for Boiler Management, Lead/Lag, and Building Management System Interface Installation Instructions February 14, 2017 Description A TS MS Series Master Lead/Lag Panel sequences
More informationSER8300 Series Line Voltage Room Controller with Optional PIR Sensor Installation Guide
Line Voltage Room Controller with Optional PIR Sensor Commercial and Hotel/Lodging HVAC Fan Coil Applications CONTENTS Installation 3 Location 3 Installation 3 Terminal, Identification and Function 4 Communication
More informationUSER'S INFORMATION MANUAL
USER'S INFORMATION MANUAL NFC 280 NFC Capable Android Devices TABLE OF CONTENTS CONTACT INFORMATION. 1 Icon Definitions.... 2 Page titles.. 3 Home Page 4 Read Device... 5 Settings. 6 Installer and Homeowner
More informationPC PROGRAM INSTRUCTIONS FOR CREST and COPPERFIN MODELS
FB-CF-PCP_100161018_2000004582_Rev B PC PROGRAM INSTRUCTIONS FOR CREST and COPPERFIN MODELS WARNING This manual must only be used by a qualified heating installer / service technician. Read all instructions,
More informationUPDATING CONTROLLERS USING PRISM 2 Updating the VCC-X Controller
Using Prism 2 7. Click on the icon. The Job-Sites Window will appear. In the Type of CommLink Dialog Box, select CommLink 5 or USB Link II. The VCC-X Controller is equipped with the ability
More informationUSER'S GUIDE BARD-LINK TM LC /LC SOLID STATE DUAL UNIT LEAD/LAG CONTROLLER & TEC-EYE HAND-HELD DIAGNOSTIC TOOL
USER'S GUIDE BARD-LINK TM LC1000-100/LC1500-100 SOLID STATE DUAL UNIT LEAD/LAG CONTROLLER & TEC-EYE HAND-HELD DIAGNOSTIC TOOL Bard Manufacturing Company, Inc. Bryan, Ohio 43506 Since 1914...Moving ahead,
More informationBACnet VAV Actuator Start-up Guide IM 1040
BACnet VAV Actuator Start-up Guide IM 1040 Group: Controls Part Number: IM 1040 Date: 3/4/2010 Supersedes: New BACnet VAV Actuator--Electronic Output Start-up Procedures 2010 McQuay International Table
More informationSER8300 Series Line Voltage Room Controller with Optional PIR Sensor Installation Guide
Line Voltage Room Controller with Optional PIR Sensor Commercial and Hotel/Lodging HVAC Fan Coil Applications CONTENTS Installation 3 Location 3 Installation 3 Terminal, Identification and Function 4 Communication
More informationJADE Economizer Module (MODEL W7220)
JADE Economizer Module (MODEL W70) INSTALLATION INSTRUCTIONS DCV (CO ) Sensor (C7): -0 Vdc control signal; minimum impedance >50k ohm. Outputs Actuator signal: -0 Vdc; minimum actuator impedance is k ohm;
More informationSEZ7656R1045B / SEZ7656H1045B
SEZ7656R1045B / SEZ7656H1045B Installation Guide f BACnet MS-TP RTU / HP Room Controllers F Commercial Zoning Systems CONTENTS Installation 2 Location 2 Installation 2 BACnet System Overview 3 Terminal,
More informationOWNER S MANUAL WIRE CONTROLLER OF AIR CONDITIONER. MODEL: KJR-12B/DPBG(T)-E Brivis Part No:B026000
OWNER S MANUAL WIRE CONTROLLER OF AIR CONDITIONER MODEL: KJR-12B/DPBG(T)-E Brivis Part No:B026000 Brivis Climate Systems Pty Ltd Tel:1300 BRIVIS brivis.com.au Thank you very much for purchasing our product.
More informationJames Donahue Control Consultants, Inc.
James Donahue Control Consultants, Inc. Founded 1989 NE s premier distributor of Building Automation products Customer Base: Controls Contractors and Systems Integrators In-House Engineering Department
More informationIQ-MP Gateway. Version apr Electrocom Rødeledsvej 95 DK-5700 Svendborg Denmark Tel :
IQ-MP Gateway Version 4.009 28. apr. 2011 Electrocom Rødeledsvej 95 DK-5700 Svendborg Denmark Tel : +45 8880 7580 www.electrocom.dk p. 2 Description The IQ-MP Gateway is a communications module, which
More informationEZT-550 Controller Instruction Manual
EZT-550 Controller Instruction Manual 56121 REV B 8-05 TABLE OF CONTENTS 1. Overview...4 1.1 Menu Bar Function Tree...4 1.2 Touch Screen Interface...6 2. Monitoring...7 2.1 Chamber Monitor...7 2.2 Chamber
More informationTrailer & Rail Refrigeration Units
EASY TO RUN X4 7300/7500 Trailer & Rail Refrigeration Units Display Display Screens Starting Unit IntelliSet Pretrip Changing Setpoint Start-Stop or Continuous Operation Data Recorder/Trip Start Manual
More informationTR150 DRIVE STANDARD FEATURES
TR150 DRIVE STANDARD FEATURES The TR150 Drive The TR150 Drive Series is a microprocessor-based, high frequency IGBT-based, PWM AC drive with control functions and software designed solely for the unique
More informationFeatures and Benefits of XeteX Controls. Other Unit Control Functions. Energy Recovery Functions
Controls Guide for XeteX Units Beyond meeting the typical specification and performance requirements, controlling the equipment is usually the most important success factor for HVAC projects. XeteX provides
More informationBACVIEW DEVICE INTERFACE For DDC Software Version Software Configuration Guide (11/2015)
DEVICE INTERFACE For DDC Software Version 7.05.03 Software Configuration Guide 8733940857 (11/2015) 2 Table of contents TABLE OF CONTENTS Key to Symbols... 3 Warnings... 3 BACview Interfaces... 3 BACview
More informationIntesisBox. v.0.1. User Manual Issue Date: 12/2017 r1.3 EN
IntesisBox HS-RC-MBS-1 v.0.1 Modbus RTU (EIA-485) Interface for Hisense air conditioners. Compatible with commercial line of air conditioners commercialized by Hisense. User Manual Issue Date: 12/2017
More informationEconomizer Controller Installation Guide
Economizer Controller Installation Guide PD 9/20/2013 - v 1.2 2 Table of Contents INPUTS... 3 OUTPUTS... 3 WHILE INSTALLING THIS CONTROLLER... 3 ACCESSORIES... 3 OPTIONAL ACCESSORIES... 3 INSTALLATION
More informationARCTIC AIR DC OLED. Digital Control Operations Manual
ARCTIC AIR DC OLED Digital Control Operations Manual Micro Air Corporation Phone (609) 259-2636 124 Route 526 WWW.Microair.net Allentown NJ 08501 Fax (609) 259-6601 Before you start: 1. Applying power:
More informationSEZ7656E1045B. Installation Guide for BACnet MS/TP RTU Terminal with IAQ Control CONTENTS
SEZ7656E1045B Installation Guide f BACnet MS/TP RTU Terminal with IAQ Control CONTENTS Installation 2 Location 2 Installation 2 BACnet System Overview 3 Terminal, Identification and Function 4 Wiring 4
More informationUPDATING CONTROLLERS USING PRISM 2 Updating the VCB-X / VCC-X Controller
Updating the VCB-X / VCC-X Controller Updating the VCB-X / VCC-X Controller Using Prism 2 Version 4.5.0 and higher The VCB-X and VCC-X Controllers are equipped with the ability to update their software
More informationTable of Contents. RTU Open Controller
RTU Open Controller Integration Guide CARRIER CORPORATION 2010 A member of the United Technologies Corporation family Stock symbol UTX Catalog No. 11-808-428-01 11/19/2010 Table of Contents Introduction...
More informationCarrier ComfortChoice Touch ZigBee Certified Thermostat Technical Specifications
Carrier ComfortChoice Touch ZigBee Certified Thermostat Technical Specifications Physical & Operational Characteristics Height 4.75 Width 5.5 Thickness (Stacked) 1.3 Thickness (User Interface, Un-stacked)
More informationKE2 MasterView Overview
Q.1.19 April 2015 KE2 MasterView Overview Accessing the web page of a KE2 Evaporator Efficiency controller reveals a great deal of information about the system performance, setpoints and allows for quick
More informationINSTALLATION, OPERATION & MAINTENANCE MANUAL INTEGRATED PROGRAMMABLE CONTROLS
INSTALLATION, OPERATION & MAINTENANCE MANUAL FOR EV450, ALL HE, LE AND RD UNITS Carel c.pco Mini Carel c.pcoe Expansion Board WWW.RENEWAIRE.COM IMPORTANT SAFETY INFORMATION WARNING Arc flash and electric
More informationGenset control and protection with safety system
APPLICATION NOTES Generator Protection Unit, GPU-3 APPLICATION NOTES Genset control and protection with safety system Application description Functional description Wiring I/O lists Basic setup Flowcharts
More informationSymmetra MW kw 380/400/480 V Operation. UPS System with External Bypass 01/
Symmetra MW 800 1600 kw 380/400/480 V Operation UPS System with External Bypass 01/2017 www.schneider-electric.com Legal Information The Schneider Electric brand and any registered trademarks of Schneider
More informationSeries 8L Alarm Aux Setpoint Configuration
Series 8L Alarm Aux Setpoint Configuration Procedure 1. Connect the Series 8L communication terminals to the Slave 1 RS485 terminals on the 9XXX controller. a. The Series 8L controller terminals for communication
More informationFRICK QUANTUM LX COMPRESSOR CONTROL PANEL
Form S90-022 M (JULY 2008) - SERVICE File: SERVICE MANUAL - SECTION 90 Replaces: S90-020 M/MAY 2007 Dist: 3, 3a, 3b, 3c QUANTUM LX COMPRESSOR CONTROL PANEL VERSION 6.5x Page 2 TABLE OF CONTENTS QUANTUM
More informationWIRED REMOTE CONTROLLER OPERATION MANUAL
WIRED REMOTE CONTROLLER OPERATION MANUAL BRCE6 Thank you for purchasing this product. This manual describes safety precautions required for the use of the product. Read this manual carefully and be sure
More informationInstallation and Operation Instructions
33ZC ComfortID Test and Balance Tool Software Installation and Operation Instructions Part Number 33ZCBAL-SA INSTALLATION The ComfortID Test and Balance Tool software requires no special installation.
More information32MP Gateway. Overview and Configuration Manual
32MP Gateway Overview and Configuration Manual 32MP Gateway Overview and Configuration Manual This document is the property of Carrier Corporation and is delivered on the express condition that it is not
More informationTracer Controls. Tracer ZN517 Unitary Controller BAS-PRC012-EN
Tracer Controls Tracer Unitary Controller 7 April 2003 BAS-PRC012-EN Introduction The Tracer unitary controller provides digital control that is similar to that of a wall thermostat. It supports the following
More informationMICRO GROW GREENHOUSE SYSTEMS, INC ZEVO DR., SUITE B-1, TEMECULA, CA PHONE (951) FAX
MICRO GROW GREENHOUSE SYSTEMS, INC 4065 ZEVO DR., SUITE B-, TEMECULA, CA 9590 PHONE (95)-96-3340 FAX (95)-96-3350 Growstat Series VENTSTAT GENERAL INSTALLATION PROCEDURES PANEL MOUNTING Mount the control
More informationTR100-A / TR200-A. Temperature / Humidity Data Loggers. Users Manual. For detailed specifications and ordering info go to
TR100-A / TR200-A Temperature / Humidity Data Loggers Users Manual For detailed specifications and ordering info go to www.testequipmentdepot.com TR100-A / TR200-A Temperature / Humidity Data Loggers English
More informationPreliminary Supplement Instructions
48/50PG03---28, 48/50PM16---28 EnergyX Factory---Installed Energy Recovery Ventilator With COMFORTLink Controls and Puronr (R---410A) Refrigerant Preliminary Supplement Instructions This document is a
More informationGRUNDFOS INSTRUCTIONS. Control MPC. Installation and operating instructions
GRUNDFOS INSTRUCTIONS Control MPC Installation and operating instructions English (GB) English (GB) Installation and operating instructions Original installation and operating instructions CONTENTS Page
More informationINSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS EIFM CONTROL REPLACEMENT KIT 8620-239 For Use with 3-1/2 Through 6 Ton Wall Mount Air Conditioners and Heat Pumps with EIFM-5* Economizers or "E" Vent Option Bard Manufacturing
More informationCDD Carbon Dioxide Transmitter
Introduction The OSA CO2 transmitter uses Infrared Technology to monitor CO2 levels within a range of 0 2000 ppm and outputs a linear 4-20 ma or 0-5/0-10 Vdc signal. The enclosure is designed to operate
More informationOwner s Manual RBC-AX32U(W)-E RBC-AX32U(WS)-E AIR CONDITIONER (SPLIT TYPE) Wireless remote controller kit. Model name: English.
AIR CDITIER (SPLIT TYPE) Owner s Manual Wireless remote controller kit Model name: RBC-AX3U(W)-E RBC-AX3U(WS)-E Generic model name RBC-AX3U(W)-E Wireless remote controller model name WH-LSE Signal receiving
More informationES-600 Ozone Controller Operation Manual
ES-600 Ozone Controller Operation Manual Questions about your product? Find answers here: Web: www.ozonesolutions.com/es-600 Phone: 712-439-6880 Ozone Solutions OZONE CONTROLLER Model ES-600 Instructions
More informationSECTION GRAPHICS
SECTION 25 15 23 GRAPHICS PART 1 - General 1.1 SUMMARY A. Section includes the general requirements for graphic generation. B. Related Sections: 1. 25 12 23 Client-Server Information/Database Integration
More informationIntroduction. What is the RTU Open controller?
RTU Open v5 CARRIER CORPORATION 2018 A member of the United Technologies Corporation family Stock symbol UTX Catalog No. 11-808-697-01 6/11/2018 Verify that you have the most current version of this document
More informationSPECIFICATIONS Temperature Setting Range: Ambient Temperature Humidity Display Range: Screen lock & configuration password:
1 FEATURES 5-inch touch & color screen Humanized operator interface Two kinds of display style Schedule setting in simple way Control your device with your cell-phone Compressor protection 12 wiring connections
More informationInstallation and Operation Manual. ETV Platinum Plus. Electronic Tempering Valve with Safeguard WARNING
Installation and Operation Manual ETV Platinum Plus Electronic Tempering Valve with Safeguard WARNING This Heat-Timer control is strictly an operating control; it should never be used as a primary limit
More informationHYgro-blu. Instruction Manual
HYgro-blu Instruction Manual HYgro-Blu HYgro-Blu Lite Basic Features HYgro-blu is an environmental sensor system designed to measure Humidity, Temperature and Atmospheric Pressure using advanced sensors
More informationCOND. A ENABLE RELAY CONTACT COOLA ENABLE 24 VAC. RATING IS 1 AMP COND. B ENABLE COOL B ENABLE.
Factory Packaged Controls Coil Products Two Head Pressure Module Orion No.:OE370-23-HP2C 1 2 3 4 www.aaon.com www.orioncontrols.com Circuit A1 TRANSDUCER #1 Circuit A2 TRANSDUCER #2 Circuit B1 TRANSDUCER
More informationSidewinder Pumps Inc. AC C1D2 Timer/Controller
Sidewinder Pumps Inc. AC C1D2 Timer/Controller Page 1 of 14 Rev 4/26/17 Table of Contents 1. Warnings --------------------------------------------------------------------------------------------------
More informationInstallation, Start-up and Operating Instructions
Installation, Start-up and Operating Instructions EVOLUTION SMART SENSOR FOR ZONING Cancels: NEW II ZONESMS-0-1 7-04 NOTE: Read the entire instruction manual before starting the installation. This symbol
More informationSmart Series. Wall Heater Operations Manual. Save This Manual
Smart Series Wall Heater Operations Manual Models: HT2024SS FSSWH2004 HT1502SS FSSWH1502 240V, 2000W 240V, 2000W 120V, 1500W 120V, 1500W Save This Manual Index Features that are functional... pg. 3 Thermostat
More information