Install-It-Yourself Batch Oven Kits
|
|
- Sophia Deborah Pearson
- 5 years ago
- Views:
Transcription
1 Install-It-Yourself Batch Oven Kits Flexibility with standard assembled or installit-yourself ovens for preheating, drying and curing for applications up to 00 F (260 C). Durability provided from quality components such as aluminized steel, insulated-panel walls and roofs, industrial grade fans and state-of-the-art controls. Energy-efficient direct-fired burners having a : turndown ratio. Better oven balance, cleanliness and space usage from unique duct design. Dependable operation when installed, used and maintained properly. Lower installation costs by installing it yourself. Versatility provided by custom designs and sizes. Model 88 assembled oven shown You ll Value Our Experience!
2 STANDARD BATCH OVENSS Horizontal (Standard) Supply Fan Motor Wiring Enclosure Optional Rear Doors Gas Train Batch Oven Back Front Doors Burner Filter Box Control Panel (Field Locate) Exhaust Fan Batch Oven Front Standard Features 6" (.2 cm) thick aluminized steel, insulated-panel construction Top mounted burner box system for natural gas or propane Double doors on one end Ceiling-mounted ductwork distribution Powered exhaust fan Automatic purge cycle UL-listed electrical control panel 460 VAC, Ø, 60 Hz Digital temperature controller Batch timer Electronic burner and high-temperature limit controls Flame safety control with UV scanner Controls designed to be Factory Mutual (FM) compliant Automatic shutdown when a pre-set cool down temperature is achieved Designed and built to comply with industry standards Air Flow Design End View Duct Work Nozzles Duct Work and Nozzles Clear Work Area 2
3 Model STANDARD BATCH OVEN SPECIFICATIONS * Clearance Opening 6 x 6 x 6 (8 x 8 x 8) 6 x 6 x (8 x 8 x 0) 6 x 6 x (8 x 8 x 47) 6 x 6 x (8 x 8 x 6) 6 x 6 x 2 (8 x 8 x 762) 8 x 8 x (244 x 244 x 0) 8 x 8 x (244 x 244 x 47) 8 x 8 x (244 x 244 x 6) 8 x 8 x 2 (244 x 244 x 762) 8 x 8 x 0 (244 x 244 x 94) 8 x 8 x (244 x 244 x 67) 8 x 8 x 40 (244 x 244 x 29) 8 x 8 x 4 (244 x 244 x 72) 8 x 8 x 0 (244 x 244 x 24) 8 x 8 x (244 x 244 x 676) x 8 x (0 x 244 x 0) x 8 x (0 x 244 x 47) x 8 x (0 x 244 x 6) x 8 x 2 (0 x 244 x 762) x 8 x 0 (0 x 244 x 94) x 8 x (0 x 244 x 67) x 8 x 40 (0 x 244 x 29) x 8 x 4 (0 x 244 x 72) x 8 x 0 (0 x 244 x 24) x 8 x (0 x 244 x 676) x x (0 x 0 x 0) x x (0 x 0 x 47) x x (0 x 0 x 6) Outside 8. x 8 x 8 (29 x 244 x 244) 8. x 8 x 2 (29 x 244 x 66) 8. x 8 x 7 (29 x 244 x 8) 8. x 8 x 22 (29 x 244 x 67) 8. x 8 x 27 (29 x 244 x 82). x x 2 ( x 0 x 66). x x 7 ( x 0 x 8). x x 22 ( x 0 x 67). x x 27 ( x 0 x 82). x x 2 ( x 0 x 97). x x 7 ( x 0 x 28). x x 42 ( x 0 x 280). x x 47 ( x 0 x 4). x x 2 ( x 0 x 8). x x 7 ( x 0 x 77) 2. x x 2 (8 x 0 x 66) 2. x x 7 (8 x 0 x 8) 2. x x 22 (8 x 0 x 67) 2. x x 27 (8 x 0 x 82) 2. x x 2 (8 x 0 x 97) 2. x x 7 (8 x 0 x 28) 2. x x 42 (8 x 0 x 280) 2. x x 47 (8 x 0 x 4) 2. x x 2 (8 x 0 x 8) 2. x x 7 (8 x 0 x 77) 2. x 2 x 2 (8 x 66 x 66) 2. x 2 x 7 (8 x 66 x 8) 2. x 2 x 22 (8 x 66 x 67) Total 6,000 (2,722) 7,000 (,7) 8,0 (,79) 9,800 (4,44),000 (4,990) 9,0 (4,7),000 (4,990) (,62) 4,000 (6,0), (7,22) 7,400 (7,892) 9,00 (8,74),700 (9,89) 22,0 (,070) 2, (,84),00 (4,76) 2,000 (,44),800 (6,260),800 (7,67) 7,00 (7,847) 9,0 (8,709),800 (9,4) 2 (,297) 24,0 (,977) 26,0 (,89) 2,000 (,44), (6,0) 6,000 (7,27).4 x.7 x 7.2 (6 x x 29).4 x.7 x 8.7 (6 x x 26).4 x.7 x 8.7 (6 x x 26).9 x. x (80 x x ).9 x. x (80 x x ).4 x.7 x 8.7 (6 x x 26).9 x. x (80 x x ).9 x. x (80 x x ) 6.4 x.4 x.6 (9 x 4 x 4) 7. x.8 x 2. (22 x 6 x 69) 7. x.8 x 2. (22 x 6 x 7) 7.8 x 4. x 2.8 (28 x x 90) 7.8 x 4. x 2.8 (28 x x 90) 7.8 x 4. x 2.9 (28 x x 9).9 x. x (80 x x ).9 x. x (80 x x ) 6.4 x.4 x.6 (9 x 4 x 4) 7. x.8 x 2. (22 x 6 x 69) 7. x.8 x 2. (22 x 6 x 7) 7.8 x 4. x 2.8 (28 x x 90) 7.8 x 4. x 2.9 (28 x x 9) 8. x 4.9 x.8 (2 x 49 x 42).9 x. x (80 x x ) 6.4 x.4 x.6 (9 x 4 x 4) 7. x.8 x 2. (22 x 6 x 69) (90),400 (6),400 (6),800 (86) (726) (9) 2,00 (,4) (,79) (,6) (,6),0 (,406) (,42) 2,0 (,000) (,79) (,79) (,6),0 (,406) (,42) (,42),800 (,724) 2,000 (907) 2,0 (998) (,79) Gas Burner Output Btu/h x 00 (kw) 00 (0.09) 40 (0.) 600 (0.8) 600 (0.8),0 (0.),00 (0.44),800 (0.) (0.62),0 (0.),00 (0.44),800 (0.) (0.62),00 (0.97) (.06),0 (0.),800 (0.) Recirculation Fan CFM (m /h),700 (2,890) (4,90) 4,000 (6,800),600 (9,) 6,0 (,40) 4,000 (6,800),600 (9,) 7,00 (2,70),000 (7,000) 2,000 (,400) 4,000 (2,800) 6,000 (27,0) 7,000 (28,) 8,000 (0,600),000 (4,000),600 (9,) 7,00 (2,70),000 (7,000) 2,000 (,400) 4,000 (2,800) 6,000 (27,0) 8,000 (0,600),000 (4,000) 22,000 (7,400) 24,000 (40,800) 6,0 (,40) 8,00 (4,40) 2,000 (,400) Motor Size 2 (0) (2.) (2.) (2.) (2.) * Specifications subject to change based on final engineering, specific applications and/or specific installations. S * CFM (m /h) 400 (680) 70 (969) 70 (969) (,9) (,9) 70 (969) (,9) (,479),0 (,74) (2,2) (2,2) (,9) (,479),0 (,74) (2,2) (2,2) (,70) (,9) (,479) (2,2) Exhaust Fan Motor Size
4 Model STANDARD BATCH OVEN SPECIFICATIONS * Clearance Opening Outside Total S * Gas Burner Output Btu/h x 00 (kw) Recirculation Fan CFM (m /h) Motor Size (.00) (.00) (.00) (.00) (.00) (.00) 2 (8.0) (.00) (.00) 2 (8.0) 2 (8.0) 0 (22.0) 40 (0.00) 2 x x 2 (0 x 0 x 762) 2. x 2 x 27 (8 x 66 x 82) 7,800 (8,074) 7. x.8 x 2. (22 x 6 x 7) (,22) (0.62) 4,000 (2,800) 0 x x 0 (0 x 0 x 94) 2. x 2 x 2 (8 x 66 x 97) 9, (9,026) 7.8 x 4. x 2.9 (28 x x 9),0 (,406) 7,000 (28,) x x (0 x 0 x 67) 2. x 2 x 7 (8 x 66 x 28) 2 (9,94) (,42) 9,000 (2,00) 40 x x 40 (0 x 0 x 29) 2. x 2 x 42 (8 x 66 x 280) 2 (,70) (,42) 22,000 (7,400) 4 x x 4 (0 x 0 x 72) 2. x 2 x 47 (8 x 66 x 4) 2,700 (,67) 8. x 4.9 x.9 (2 x 49 x 424),800 (,724),00 (0.97) 2,000 (42,00) 0 x x 0 (0 x 0 x 24) 2. x 2 x 2 (8 x 66 x 8) 27,400 (2,428) 8. x 4.9 x.9 (2 x 49 x 424),800 (,724) (.06) 28,000 (47,600) x x (0 x 0 x 676) 2. x x 7 (8 x 96 x 77),000 (4,06) 8. x. x 4.7 (2 x 62 x 448) 4,00 (,90) (.06) 0,000 (,000) 2 2 x x (66 x 0 x 0) 4. x 2 x 2 (442 x 66 x 66),0 (,987).9 x. x.2 (80 x x 4) (9),0 (0.) 7,00 (2,70) 2 2 x x (66 x 0 x 47) 4. x 2 x 7 (442 x 66 x 8),00 (7,0) 7. x.8 x 2. (22 x 6 x 69) (,79),00 (0.44),000 (8,700) 2 2 x x 4. x 2 x 22 7,00 7. x.8 x 2. 4,000 (66 x 0 x 6) (442 x 66 x 67) (7,847) (22 x 6 x 7) (,22) (0.62) (2,800) 22 2 x x 2 (66 x 0 x 762) 4. x 2 x 27 (442 x 66 x 82) 9,600 (8,890) 7.8 x 4. x 2.9 (28 x x 9),0 (,4) 7,000 (28,) 20 2 x x 0 (66 x 0 x 94) 4. x 2 x 2 (442 x 66 x 97) (9,84),00 (,88) 9,000 (2,00) 2 2 x x (66 x 0 x 67) 4. x 2 x 7 (442 x 66 x 28) 2,00 (,69),00 (,88) 22,000 (7,400) x x 40 (66 x 0 x 29) 4. x 2 x 42 (442 x 66 x 280) 2,700 (,67) 8. x 4.9 x.9 (2 x 49 x 424), (,769),00 (0.97) 2,000 (42,00) 24 2 x x 4 (66 x 0 x 72) 4. x 2 x 47 (442 x 66 x 4) 27,00 (2,474) 8. x 4.9 x.9 (2 x 49 x 424), (,769) (.06) 28,000 (47,600) 20 2 x x 0 (66 x 0 x 24) 4. x x 2 (442 x 96 x 8),0 (4,7) 8. x. x 4.7 (2 x 62 x 448) 4,00 (,90) (.06) 0,000 (,000) 2 2 x x (66 x 0 x 676) 4. x x 7 (442 x 96 x 77) (,0) 8. x. x 4.7 (2 x 62 x 448) 4,700 (2,2) 4,0 (.2) (6,0) 22 2 x 2 x (66 x 66 x 0) 4. x 4 x 2 (442 x 427 x 66),0 (6,849) 6.4 x.4 x.6 (9 x 4 x 4) 2,00 (,4),0 (0.) 8,000 () 22 2 x 2 x (66 x 66 x 47) 4. x 4 x 7 (442 x 427 x 8) 7,400 (7,89) 7. x.8 x 2. (22 x 6 x 7) 2, (,),800 (0.) 2,000 (,400) 22 2 x 2 x (66 x 66 x 6) 4. x 4 x 22 (442 x 427 x 67) 9, (9,027) 7.8 x 4. x 2.9 (28 x x 9) (,42) 6,000 (27,0) x 2 x 2 (66 x 66 x 762) 4. x 4 x 27 (442 x 427 x 82) 22,0 (,070),700 (,678) 9,000 (2,00) x 2 x 0 (66 x 66 x 94) 4. x 4 x 2 (442 x 427 x 97) 24,00 (,) 8. x 4.9 x.9 (2 x 49 x 424) 4,000 (,84) 2 (9,0) 22 2 x 2 x 4. x 4 x 7 26, x 4.9 x.9 4,000,00 26,000 (66 x 66 x 67) (442 x 427 x 28) (,97) (2 x 49 x 424) (,84) (0.97) (44,0) x 2 x 40 (66 x 66 x 29) 4. x 4 x 42 (442 x 427 x 280) 28,700 (,08) 8. x 4.9 x 4 (2 x 49 x 427) 4,00 (,90) (.06) 29,000 (49,00) x 2 x 4 (66 x 66 x 72) 4. x x 47 (442 x 47 x 4) (4,787) 8. x. x 4.8 (2 x 62 x 4) 4, (2,22) 4,0 (.2) 2,000 (4,400) x 2 x 0 (66 x 66 x 24) 4. x x 2 (442 x 47 x 8) 4,800 (,78) 8. x. x 4.8 (2 x 62 x 4),000 (2,268) 4,0 (.2),000 (9,00) 22 2 x 2 x (66 x 66 x 676) 4. x x 7 (442 x 47 x 77) 6, (6,78) 8. x. x 4.8 (2 x 62 x 4),0 (2,) 7,800 (2.29) 8,000 (64,600) * Specifications subject to change based on final engineering, specific applications and/or specific installations. Exhaust Fan CFM (m /h) (2,2) (,70) (70) (479) (74) 00 (22) (,70) (,70) 2,00 (4,20) (,479) (2,2) (,70) 2,00 (4,20) 2,00 (4,20) 2,800 (4,760) Motor Size 4
5 STANDARD BATCH OVENSS Shipping Configurations Side or End Mount Vertical (Optional) Fan Motor Wiring Enclosure Gas Train Burner Filter Box Complete assemblies consisting of: Burner box and gas manifold Electrical control panel Powered exhaust fan 6" (.2 cm) insulated panels and trim packages are palletized Pre-fabricated doors including all hardware Pre-fabricated, pre-formed and assembled ductwork Fasteners, mounting hardware, as well as complete assembly, start up and operating instructions included Options Floor:.2" (.64 cm) hot roll steel plate or " (7.6 cm) insulated panels with cart wheel slots End or side mounted burner box Air impingement side wall ducts Double doors on both ends Chart recorder Door-activated low-fire switch Programmable logic controller Stack kits Canadian specifications Technical Standards and Safety Authority support documentation Low NOx burners Electric Heat /2 VAC, Ø, 60 Hz 8/240 VAC, Ø, 60 Hz Installation and startup by Rapid Engineering LLC Insulated Oven Panels Batch Oven Applications Pre-heating Curing Drying Off Low Temperature Stress Relieving, Exhaust Fan and Control Panel stacked to ship Prepares metal, medium-density fiberboard or other substrates for the coating process. Elevates part and coating temperatures to achieve the desired coating performance. Efficient air distribution without excessive air turbulence. Drying water or moisture accumulated during the pre-treatment washing process. Used to reduce internal residual stresses in a metal object by heating the object to a suitable temperature and holding at the temperature for a proper amount of time. Out Gassing Aids the release of gasses that are trapped or absorbed in some materials.
6 The RAPID Advantage Quality products and reliable performance Project management support Design, manufacturing, installation and service capabilities Extensive experience Single source supply for components On-time and on-budget delivery For a quote, call us at or send us an at IPFEsales@rapidengineering.com Thank You for Your Business! These products are not for residential use. This document is intended to assist licensed professionals in the exercise of their professional judgment. Rapid Engineering LLC 0 Seven Mile Road NW Comstock Park, MI 492 Telephone: Toll Free: Fax: Rapid Engineering LLC All rights reserved. No part of this work covered by the copyrights herein may be reproduced or copied in any form or by any means graphic, electronic, or mechanical, including photocopying, recording, taping, or information storage and retrieval systems without written permission of Rapid Engineering LLC. Printed in U.S.A. RPBOSNA 26 Rev H
Install-It-Yourself Batch Oven Kits
Install-It-Yourself Batch Oven Kits Flexibility with standard assembled or installit-yourself ovens for preheating, drying and curing for applications up to 00 F (260 C). Durability provided from quality
More informationPrecision Cooling Mission Critical Air Handling Units
M I S S I O N C R I T I CA L C O O L I N G Precision Cooling Mission Critical Air Handling Units Global Expertise for Precision Cooling Solutions STULZ is a privately owned, global manufacturer of highly
More informationCannon T4 Modular Data Center (MDC)
SOLUTIONS Cannon T4 Modular Data Center (MDC) Cannon T4 Modular Data Centers are part of Cannon T4 Data Center Solutions Cannon T4 Data Center Solutions Overview T4 Data Centers T4 Mini Data Centers T4
More informationChilled Water Computer Room Air Handler (CRAH) Critical Infrastructure for the World s Leading Data Centers
Chilled Water Computer Room Air Handler (CRAH) Critical Infrastructure for the World s Leading Data Centers DATA CENTER COOLING EXPERTISE Data Center managers have unique needs. Nortek Air Solutions listens
More informationINFRARED RADIANT GAS SYSTEMS FOR THERMAL TREATMENTS
INFRARED RADIANT GAS SYSTEMS FOR THERMAL TREATMENTS www.infragas.com INFRAGAS IR CATALYTIC GAS HEATERS WHO WE ARE Since 1971 INFRAGAS designes and produces infrared catalytic gas systems specific for surface
More informationMCFCW-20-4HS-1 (4-Pipe) High Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 60,000 BTUH
MCFCW-20-4HS-1 (4-Pipe) High Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 60,000 BTUH 1 Chilled and Hot Water Fan Coil High Static 4-Pipe Nominal
More informationMCFCW-08-4LS-1 (4-Pipe) Low Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 24,000 BTUH
MCFCW-08-4LS-1 (4-Pipe) Low Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 24,000 BTUH 1 Chilled and Hot Water Fan Coil Low Static 4-Pipe Nominal Size:
More informationInstallation Instructions
50ES, 50EZ, 50GL, 50GS, 50GX, 50JS, 50JX, 50JZ, 50SD, 50SZ, 50VL, 50VT, 50XP, 50XZ 601A, 602A, 602B, 604A, 604B, 604D, 607C, 701A, 702A, 702B, 704A, 704B, 704D, 707C PA1P, PA2P, PA3P, PH1P, PH2P, PH3P
More informationVariable Density, Closed-Loop, Water-Cooled Data Center Solution
Variable Density, Closed-Loop, Water-Cooled Data Center Solution Overview Great Lakes Case & Cabinet Co., Inc. has worked with Naissus Thermal Management Solutions, of Toronto, Ontario to develop one of
More informationMCFCW-06-4HS-1 (4-Pipe) High Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 18,000 BTUH
MCFCW-06-4HS-1 (4-Pipe) High Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 18,000 BTUH 1 Chilled and Hot Water Fan Coil High Static 4-Pipe Nominal
More informationA Data Center Heat Removal System That Saves... 80% Discover Inertech s Award-winning Data Center Heat Removal System
A Data Center Heat Removal System That Saves... Infrastructure Power Water up to 40% up to 80% up to 85% Discover Inertech s Award-winning Data Center Heat Removal System A Cool Solution; A Breakthrough
More informationOPEN FACE Industrial East Grand Ave., Pomona, CA Fax:
OPEN FACE Industrial Dry Booths Environmentally Safe Each Industrial Dry Booth is designed to meet or exceed safety and code requirements: NFPA- and IFC, to protect those that work in any industrial spray
More informationDUKE UNIVERSITY CONSTRUCTION STANDARDS
1 00 01 10 Table of Contents DIVISION 00: PROCUREMENT AND CONTRACTING REQUIREMENTS 00 01 10 Table of Contents 06.17.2014 00 21 13 Instructions to Bidders 11.08.2013 00 22 13 Supplementary Instructions
More informationRefrigerated incubators with forced convection
KB series (E3.1) Incubators Refrigerated incubators with forced convection The most versatile incubator for microorganisms: The BINDER KB series controls a temperature range of -5 C to 100 C. With its
More informationAPC APPLICATION NOTE #146
#146 Hot Aisle Containment Application Guidelines and Approved Configurations By Kevin Lemke Abstract The Hot Aisle Containment System (HACS) is a modular ceiling panel and door system for use in isolating
More informationCOOLING SOLUTIONS. SmartRack Close-Coupled Cooling for IT Environments
COOLING SOLUTIONS SmartRack Close-Coupled Cooling for IT Environments Efficient, flexible, manageable cooling reduces costs and simplifies installation. Efficient, flexible, manageable cooling for IT environments
More informationC-POWER AC AUTOMATIC CONTROL
Issue 1 Print 1 C-POWER AC AUTOMATIC CONTROL INSTALLATION INSTRUCTIONS & OWNER S MANUAL Model: 93 ACMC100I A Charles Industries, Ltd. All rights reserved. Printed in the United States of America. Issue
More informationDatasheet.
Industrial Test & Mixing Equipment Bringing Test Innovation to you Datasheet This product datasheet has been provided by John Godrich & SJ Electronics in Partnership with BINDER www.johngodrich.co.uk www.sjelectronics.co.uk
More informationSmartAisle. SmartAisleTM. Energy-efficient use of existing cooling power in data centers to
SmartAisleTM SmartAisle TM Energy-efficient use of existing cooling power in data centers 1.50 to 1.58 1.49 Emerson Network Power Smart Aisle TM The consistent physical separation of cold zones from warm
More informationLiebert XDA Air Flow Enhancer. User Manual
Liebert XDA Air Flow Enhancer User Manual Technical Support Site If you encounter any installation or operational issues with your product, check the pertinent section of this manual to see if the issue
More informationPREFABRICATED SUBSTATIONS AND E-HOUSES. tgood.com. Energy, Fast!
PREFABRICATED SUBSTATIONS AND E-HOUSES tgood.com Energy, Fast! Global leader in prefabricated substations and E-House systems PRODUCT OVERVIEW Fully integrated prefabricated substations and E-House systems.
More informationDDDM 45 (40-60 TPH) DDDM 60 ( TPH) COLD AGGREGATE FEEDER. Auxiliary belt No. of bins. Gathering conveyor reduction gear
I TECHNICAL SPECIFICATIONS ROAD BUILDING DDDM 45 (40-60 TPH) DOUBLE DRUM ASPHALT PLANT - DDDM 50 (60-90 TPH) DDDM 60 (90-120 TPH) COLD AGGREGATE FEEDER Stationary four bin cold aggregate feeder unit is
More informationU V-Tu r b o h o o d s
U V-Tu r b o h o o d s Product description, Product code Parts Functioning principle Dimensions Exhaust air, pressure loss and sound data Supply air, pressure loss and sound data Distribution of supply
More informationMoving Containment Inside the Enclosure. Jeff Markle Great Lakes Case & Cabinet
Moving Containment Inside the Enclosure Presented by Jeff Markle Great Lakes Case & Cabinet Containment Containment : To put constraint upon; to restrain; to confine; to keep within bounds Containment
More information1/2 Introduction. SIMBOX LC 1/7 Introduction 1/8 Flush-mounting and surfacemounting. 1/9 Dimensional drawings
Siemens AG 200 ALPHA SIMBOX Small Distribution Boards /2 Introduction /2 Introduction /3 Flush-mounting and hollow-wall distribution boards /4 Hood-type distribution boards /5 Accessories /6 Dimensional
More informationInstruction Sheet Board Style Low Water Cutoff
Instruction Sheet Board Style Low Water Cutoff 102-305 SUPERSEDES: REVISION E DATED December 12, 2007 #5401173-REV F PLANT ID 001-3902 US Patents 6,904,800, 7,243,540, and 7,317,993 Other Patents Pending
More informationReverse Flow Cabinet. ContraFlo Cabinet. Reverse Flow Cabinet for Raised Floor Data Centers
Reverse Flow Cabinet ContraFlo Cabinet Reverse Flow Cabinet for Raised Floor Data Centers ContraFlo TM Cabinet Reverse Flow Cabinet The ContraFlo cabinet turns airflow upside down to offer an alternative
More informationRittalXpress TS IT Enclosure Assemble-to-Order Program
RittalXpress TS IT Enclosure Assemble-to-Order Program DESIGN YOUR DATA CENTER BY THE NUMBERS. Count down to success: 4, 3, 2, 1... Complete four easy steps, your order can be shipped in three days and
More informationThermal management. Thermal management
Thermal management Thermal management Managing thermal loads is a major challenge for all Data Centre operators. Effecting proper control of the thermal environment drives energy consumption and ultimately
More informationHow to Design Custom Enclosures for Motherboard-Based Systems
PROTOCASE TECHNICAL BULLETIN How to Design Custom Enclosures for Motherboard-Based Systems (covering ATX and Mini ITX form factors) Document Edition - 1 Last Updated: June 6 th,2011 Protocase, Inc. All
More informationTABLE OF CONTENTS PRODUCT INFORMATION... 3 SPECIFICATIONS... 4 IMPORTANT SAFETY INSTRUCTIONS... 5
8670 SERIES MANUAL TABLE OF CONTENTS PRODUCT INFORMATION... 3 SPECIFICATIONS... 4 IMPORTANT SAFETY INSTRUCTIONS... 5 INSTALLATION INFORMATION... 5-6 GENERAL INFORMATION 5 WIRING INFO... 6 MOUNTING DIMENSIONS
More informationDuct Pulsation Problem Captured and Solved Using STAR-CCM+
Duct Pulsation Problem Captured and Solved Using STAR-CCM+ Eric Duplain, Eng., M.Eng. (BMA) François McKenty, Eng., Ph.D. (BMA) Normand Brais, Eng., Ph.D. (BMA) John Viskup, President (Victory Energy)
More information3190 Series Touch Screen POS Workstation
3190 Series Touch Screen POS Workstation INSTALLATION GUIDE Congratulations on your purchase of UTC RETAIL s innovative 3190 Series Touch Screen POS Workstation. The 3190 Series is designed for use in
More informationFTTX Fiber Optic Cabinet Packages Priority Electronics USA
Priority Electronics USA Priority Electronics Ltd Application Hoffman FTTX enclosures are designed to protect and manage fiber optic cable for broadband delivery in outdoor applications. Constructed with
More informationData Center Enclosures Best Practices. Maximize the Efficiency of the Enclosure within a Data Center
Data Center Enclosures Best Practices Maximize the Efficiency of the Enclosure within a Data Center Things to ask before selecting Enclosures: Primary Use Severs or Patching, or both determines size. RMU
More informationGOLDENI. Owners Manual & Safety Instructions. English. model# GOLDi600. Copyright 2017 Smart Grow Technologies, INC All Rights Reserved
GOLDENI 600 model# GOLDi600 English Copyright 2017 Smart Grow Technologies, INC All Rights Reserved Owners Manual & Safety Instructions INTRODUCTION This User Manual is for Smart Grow Technologies (SGS):
More informationCLASSIFICATION OF FIRE RESISTANCE PERFORMANCE ACCORDING TO EN :2007+A1:2009 OF A ROLLING SHUTTER TYPE METACON RGS EI (1) 120 MOUNTED ON A WALL
CLASSIFICATION OF FIRE RESISTANCE PERFORMANCE ACCORDING TO EN 13501-2:2007+A1:2009 OF A ROLLING SHUTTER TYPE METACON RGS EI (1) 120 MOUNTED ON A WALL Sponsor: Metacon BV James Wattstraat 14 2809 PA GOUDA
More informationModel KMF 720 Constant climate chambers with expanded temperature / humidity range
Model KMF 720 Constant climate chambers with expanded temperature / humidity range The BINDER KMF ensures absolutely constant test conditions throughout the testing area. A big advantage of this constant
More informationModel VDL 115 Vacuum drying chambers for flammable solvents
Model VDL 115 Vacuum drying chambers for flammable solvents A BINDER safety vacuum drying oven of the VDL series ensures maximum safety when drying organic solvents standard with TÜV/GS. The inner chamber
More informationegate Product Catalog Electronic activegate Control Stabilize your Process
Product Catalog Electronic activegate Control Stabilize your Process CAT-16-0013_EN-Rev06 EN 05/2017 Electric Valve Gate Product Description Hot Runner System Patented electronically actuated Valve Gate
More informationS66 Series Electronic Fan Speed Control
FANs 121, 125, 1628.3 Product/Technical Bulletin S66 Issue Date 0918 S66 Series Electronic Fan Speed Control The S66 Series Electronic Fan Speed Control is designed to modulate the speed of single-phase,
More informationDesign and Installation Challenges: Aisle Containment Systems
Design and Installation Challenges: Aisle Containment Systems 1 We all know the Benefits of Containment 1. Reduces Total Cost of Data Center Ownership 2. Eliminates hot spots 3. Supports higher heat and
More information1.866.TRY.GLCC WeRackYourWorld.com
cool it. 1.866.TRY.GLCC WeRackYourWorld.com In order to maximize space in the data center and accommodate for increased data, rack-mount enclosures are becoming populated with high-density servers and
More informationVLG/ Series Product Information Combination Gas / Oil MMBtu
V/ Series Product Information ombination as / Oil 1.3-16.8 MMtu The V/Series gas/oil combination burner is a forced draft packaged burner system. balanced blower wheel mounted in a fabricated housing provides
More informationP.O. Box NL-2665 ZN Bleiswijk Brandpuntlaan Zuid 16 - NL-2665 NZ Bleiswijk The Netherlands
P.O. Box 554 - NL-2665 ZN Bleiswijk Brandpuntlaan Zuid 16 - NL-2665 NZ Bleiswijk The Netherlands +31 88 3473 723 nederland@efectis.com Classification of the fire resistance according to EN 13501-2:2007+A1:2009
More informationDenton Vacuum Phoenix 400 Continuous In-Line Sputtering Deposition System General Specifications
Phoenix 400 Continuous In-Line Sputtering Deposition System s Phoenix 400X System Overview Denton Vacuum s Phoenix 400X Continuous In-Line Sputtering system provides users optimal uniform coating thicknesses
More informationON/OFF HUMIDIFIER CONTROL (ROOM 0R DUCT SENSOR) WITH OUTDOOR TEMPERATURE RESET OVERVIEW WALL CONTROLLER INSTALLATION (TCY-BH-T-U)
(ROOM 0R DUCT SENSOR) WITH OUTDOOR TEMPERATURE RESET TCY-BH-T-U Wall controller with sensor TDC-BH-T-U Duct controller with sensor SOA-Tn10 Outdoor temperature sensor (Optional) OVERVIEW For wall applications
More informationCentral Controller Operation & Installation Manual
Central Controller Operation & Installation Manual YCZ-A004 CONTENT Function introduction of central controller... 1 Part info for central controller... 2 Page & Key Explanation... 4 Address Setting When
More informationPRO II X Series CAPACITANCE PROBE
Price $5.00 PRO II X Series CAPACITANCE PROBE OPERATING INSTRUCTIONS PLEASE READ CAREFULLY 9250105.fm Rev. 2 TABLE OF CONTENTS GENERAL SPECIFICATIONS... 3 1.0 INTRODUCTION... 4 2.0 APPLICATIONS... 4 3.0
More informationThermal Diffusivity Instruments DLF-2 with EM-1600
Thermal Diffusivity Instruments DLF-2 with EM-1600 Site Preparation Guide Revision A Issued February 2017 Table of Contents Table of Contents... 1 Ideal Setup... 2-3 System Components... 3 Instrument Measurements...
More informationBlue e+ chillers with the principle
Blue e+ chillers with the principle Blue e+ chillers The world s most efficient range of chillers. The principle: Efficient Energy savings of up to 70% thanks to DC inverter technology Flexible Worldwide
More informationFree Energy Band RCC30U Room Temperature Controller for Four-pipe Fan Coil Unit
Document No. 155-324 Free Energy Band RCC30U Room Temperature Controller for Four-pipe Fan Coil Unit Description Features Application Product Number Room temperature controller for four-pipe fan coil units.
More informationF&J SPECIALTY PRODUCTS, INC.
F&J SPECIALTY PRODUCTS, INC. Digital Air Monitoring System Enzyme Dust Samplers F&J Models: DF-804DTE-30, DF-804DTE-30EC and DF-804DTE-30HT GENERAL DESCRIPTION: The DF-804E-30 series high volume enzyme
More informationSTR-3 STANDARD 3-PHASE 230 VAC TRANSFORMER CONTROLLER. Mounting and operating instructions
STANDARD 3-PHASE 230 VAC TRANSFORMER CONTROLLER Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS 3 PRODUCT DESCRIPTION 4 ARTICLE CODES 4 INTENDED AREA OF USE 4 TECHNICAL DATA
More informationIllustrated Parts List. Generator Systems. Reproduction MODEL Not for. 12,000 Watt. Generator Systems
Illustrated Parts List Generator Systems MODEL 12,000 Watt Generator Systems Manual Part No. Revision D Rev. Date: 8/9/2016 Table Of Contents PRODUCT COMPONENTS PAGES Power Group... 4 Alternator... 6
More informationGreat Lakes Product Solutions for Cisco Catalyst and Catalyst Switches: ESSAB14D Baffle for Cisco Catalyst 9513 Switch
Great Lakes Product Solutions for Cisco Catalyst and Catalyst Switches: ESSAB14D Baffle for Cisco Catalyst 9513 Switch Great Lakes Product Solutions for Cisco Catalyst and Catalyst Switches Table of Contents
More informationAC-500 XCEL DIRECT FIRED GAS CONVECTION OVEN REPLACEMENT PARTS LIST
AC-00 XCEL DIRECT FIRED GAS CONVECTION OVEN REPLACEMENT PARTS LIST EFFECTIVE APRIL 0, 0 Superseding All Previous Parts Lists. The Company reserves the right to make substitution in the event that items
More informationFacility Requirements LaserCube SYS-4x4-YLS
Introduction Facility Requirements LaserCube SYS-4x4-YLS Caution: Use of controls or adjustments or performance of procedures other than those specified herein may result in hazardous radiation exposure.
More informationBASELAYER CORE PA20 Power Module
TM TM PA20 Power Module The CORE PC20 Power Module is a state of the art switchboard and UPS featuring modularized, critical components and delivers a configurable conditioned power supply. HIGHLIGHTS
More informationFREEING HPC FROM THE DATACENTRE
FREEING HPC FROM THE DATACENTRE ku:l sistem TM COOLING REDEFINED www.iceotope.com ku:l sistem removes the need for inefficient air cooling technologies FREEING HPC FROM THE DATACENTRE Iceotope s patented
More informationPRO I Series CAPACITANCE PROBE
Price $5.00 PRO I Series CAPACITANCE PROBE OPERATING INSTRUCTIONS PLEASE READ CAREFULLY TABLE OF CONTENTS GENERAL SPECIFICATIONS... 3 1.0 INTRODUCTION... 4 2.0 APPLICATIONS... 4 3.0 INSTALLATION... 4 3.1
More information400V MDU POWER MODULE AND MDU CONTROL MODULE SET APPLICATION MANUAL V 1.1
KASKOD-MTRONIX OÜ 400V MDU POWER MODULE APPLICATION MANUAL V 1.1 Copyright KASKOD-MTRONIX OÜ. All rights reserved. No part of this publication may be reproduced or copied without prior written permission
More informationPower and Cooling for Ultra-High Density Racks and Blade Servers
Power and Cooling for Ultra-High Density Racks and Blade Servers APC White Paper #46 Richard L. Sawyer Director of Data Center Technology American Power Conversion Company 2005 APC corporation What has
More informationINSTRUCTION MANUAL RA 55 RACK ADAPTER RACK ADAPTER FOR MST SERIES POWER MODULES
INSTRUCTION MANUAL RA 55 RACK ADAPTER RACK ADAPTER FOR MST SERIES POWER MODULES KEPCO INC. An ISO 9001 Company. MODEL RA 55 RACK ADAPTER ORDER NO. REV. NO. IMPORTANT NOTES: 1) This manual is valid for
More informationSeries 575. Vertical Flow Modular Softwall Cleanroom. Series 575 Vertical Flow Modular Softwall Cleanroom
Series 575 Vertical Flow Modular Softwall Cleanroom S O L U T I O N S The Series 575 softwall cleanroom is a cost-effective method of providing quality particulate control in a softwalled enclosure. The
More informationD-Net CABINETS. D-Net cabinets are a versatile racking system suitable for housing
D-Net CABINETS D-Net cabinets are a versatile racking system suitable for housing networking and various structured cabling components. D-Net Cabinets are manufactured in Taiwan in compliance with ISO9001:2000
More informationModel KB 400 Cooling incubators with compressor technology
Model KB 400 Cooling incubators with compressor technology BENEFITS Safe and reproducible incubation conditions even at high environmental conditions Disinfection routine at 100 C MAIN FEATURES Model 400
More informationMagnum Club Smoke System
AND INSTALLATION VERSION.0 Martin Professional A/S,Olof Palmes Allé 8, DK-800,Aarhus N Phone: +45 87 40 00 00 Internet: www.martin.dk Magnum Club Smoke System Fluids Suitable for this system: CONNECTIONS
More informationWhere s the Heat Coming From. Leland Sparks Global Account Technical Consultant Belden
Where s the Heat Coming From Leland Sparks Global Account Technical Consultant Belden What is the greatest DC challenge you face? Air Flow to Heat Load Relation Server Inlet Fans Chips Outlet LOAD Dell
More informationCHAPTER 5. Special Cases
CHAPTER 5 Special Cases OVERHANGS To be treated as an overhang, slotted and louvered shading devices must have the slats arranged so that no direct solar radiation penetrates the overhang at any time during
More informationModel KT 53 Cooling incubators with thermoelectric cooling
Model KT 53 Cooling incubators with thermoelectric cooling The KT series combines outstanding performance with impressive energy efficiency and environmental friendliness. The cooled incubators of the
More informationINSTALLATION INSTRUCTIONS
Wired Remote Controller 7 Day Programmable Ductless Systems KSACN0401AAA (High Wall Models) KSACN0501AAA (Ducted/Cassette Models) INSTALLATION INSTRUCTIONS NOTE: Read the entire instruction manual before
More informationICS Entrance Management Sign Installation Guide. Version 1.0
ICS Entrance Management Sign Installation Guide Version 1.0 Thank you for purchasing your new ICS Entrance Management System (EMS) from Innovative Control Systems, Inc. Installation Overview This document
More informationSite Preparation for ClearCube Installation. Rev. F
Site Preparation for ClearCube Installation Rev. F EXECUTIVE SUMMARY Because of the centralized nature of the ClearCube architecture, installation of the system requires a certain degree of site preparation.
More informationFOX-50 Heat Flow Meter
FOX-50 Heat Flow Meter Site Preparation Guide Revision A Issued June 2016 Page 1 Table of Contents Table of Contents... 1 Ideal Setup... 2 System Components... 3 Instrument Measurements... 4 Utility Requirements...
More informationProcedure to Install an IO Expansion Cage Assembly in a Maxum II Modular Oven Analyzer
Procedure to Install an IO Expansion Cage Assembly in a Maxum II Modular Oven Analyzer Difficulty Level: Medium Estimated time to execute: 1 Hour Revision History Issue Date Reason 001 5/31/2016 Initial
More informationSite Readiness Guide. October 2017
Site Readiness Guide October 2017 Copyright This document is provided "as-is." Information and views expressed in this document, including URL and other Internet website references, may change without
More informationMNS ACS880 Switchgear mounted industrial drives
MNS ACS880 Switchgear mounted industrial drives Switchgear mounted industrial drives AC Drives are designed for installation in a normal industrial environment. However, various auxiliary equipment for
More informationWashington Square FPO. 111 Washington Square > Office Space FOR LEASE > OFFICE SPACE 111 WASHINGTON AVENUE, MINNEAPOLIS, MN 55401
FOR LEASE > OFFICE SPACE Washington Square 111 WASHINGTON AVENUE, MINNEAPOLIS, MN 55401 FPO 111 Washington Square > Office Space HENNEPIN AVE PARKING RAMP > Built in 1987, 111 Washington is part of a three
More informationALPHA Small Distribution Boards SIMBOX 63/SIMBOX WP
ALPHA Small Distribution Boards SIMBOX 63/SIMBOX WP SIMBOX 63 /4 Introduction /5 Flush mounting distribution boards /6 Hollow-wall distribution boards /7 Surface mounting distribution boards /7 Hood-type
More informationAIR COOLED MODULAR RECTIFIER
CONTROLLED POWER COMPANY SPECIFICATIONS AIR COOLED MODULAR RECTIFIER Spc1800a1 5JAN1999 SPECIFICATION S-1800-A MODULAR (REMOVABLE AND NON-REMOVABLE MODULES) AIR COOLED RECTIFIER Standard output power range:
More informationPop-Up Floor Number(s) : à à à
87045 LIMOGES Cedex Phone : 05 55 06 87 87 Fax : 05 55 06 88 88 Pop-Up Floor Number(s) : 0 540 00 à 03 0 540 05 à 08 0 540 10 à 13 0 540 CONTENTS PAGES 1.Range 1 to 2 2.Installation 3 to 5 3.Equipement
More informationPop-Up Number(s) : to 03, to 08, to 13,
87045 LIMOGES Cedex Phone : 05 55 06 87 87 Fax : 05 55 06 88 88 Pop-Up Number(s) : 0 540 00 to 03, 0 540 05 to 08, 0 540 10 to 13, CONTENTS PAGES 1.Range 1 to 3 2.Installation 4 to 8 3.Technical characteristics
More informationBrasch Washdown Unit Heaters
Brasch Washdown Unit Heaters Standard Features: Up to 48 KW Up to 400 Volts Disconnect switch with enclosure interlock Heavy-duty 304 stainless steel shroud Nema 4x non-metallic control panel 24-volt
More informationVariable Speed Drives
Technical Note 14 Variable Speed Drives On Single Phase Supplies Note: This article is intended as a guide only. It is the responsibility of the installer to define and accommodate all environmental &
More informationSite Readiness Guide. September 2015
Site Readiness Guide September 2015 Copyright This document is provided "as-is." Information and views expressed in this document, including URL and other Internet website references, may change without
More informationRiMatrix S Make easy.
RiMatrix S Make easy. 2 RiMatrix S Rittal The System. The whole is more than the sum of its parts. The same is true of Rittal The System. With this in mind, we have bundled our innovative enclosure, power
More informationSECTION PROJECTOR LIFTS AND MOUNTS. A. Refer to Section [ Submittal Procedures] [Insert section number and title].
(Specifier Note: The purpose of this guide specification is to assist the Specifier in correctly specifying AeroLift motorized projector lifts and their installation. The Specifier needs to edit these
More informationPI31xx Product Family Reflow Soldering Guidelines
APPLICATION NOTE AN:302 PI31xx Product Family Reflow Soldering Guidelines Chris Swartz Principal Applications Engineer Contents Page Introduction 1 Storage 1 Solder Paste 1 Leaded Applications 1 PCB Considerations
More informationENCLOSURE HEAT DISSIPATION
ENCLOSURE HEAT DISSIPATION DATA CENTER SOLUTIONS A White Paper by Great Lakes Case & Cabinet Company www.werackyourworld.com 814.734.7303 Page 2 Introduction Dangerous heat levels inside an enclosure threaten
More informationUser s Manual. LumiVision series. A Designer s X-ray film illuminator. Walnut, CA U.S.A. By LCD TV Technology
User s Manual A Designer s X-ray film illuminator By LCD TV Technology series Point A Technologies, Inc. Walnut, CA U.S.A. FCC RF INTERFERENCE STATEMENT NOTE: This equipment has been tested and found to
More informationRUGGED MILITARY GRADE
R4U-20A RUGGED MILITARY GRADE COTS Plus 4U ENCLOSURE Optimized for High Shock / Vibration Environments C6CHASSIS SYSTEMS ENGINEERED TO PERFORM The R4U-20A is designed to survive! Aircraft grade aluminum
More informationDell MD1280 Storage Enclosure Getting Started Guide
Dell MD1280 Storage Enclosure Getting Started Guide Regulatory Model: SP-2584, E11J Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your computer.
More information09LD/GD. Air-Cooled Condensers/Air-Cooled Fluid Coolers. Nominal cooling capacity kw 09LD/GD 09GD
Air-Cooled Condensers/Air-Cooled Fluid Coolers 09LD/GD 09GD 09LD/GD Nominal cooling capacity 281-987 kw The 09LD air-cooled condensers are designed for refrigeration plants where a halogenated hydrocarbon,
More informationECON-ZIP-BASE. ZIP Economizer Base Module
ECON-ZIP-BASE ZIP Economizer Base Module You can mount the ZIP Economizer in any orientation; it is recommended that you mount it in a position that will allow full utilization of the LCD and key pad and
More informationApplication of Modular, Rapidly Deployable CBR Filtration and Environmental Conditioning Systems for Building Collective Protection
Application of Modular, Rapidly Deployable CBR Filtration and Environmental Conditioning Systems for Building Collective Protection Carl S. Pates III, Ph.d, P.E., New World Associates John Milligan, P.E.,
More informationPackage Substation. The efficient solution for your electrical distribution network
Package Substation The efficient solution for your electrical distribution network Why Prefabricated Substations? Biosco, safe and effective substations Safety: A fully tested electrical equipment > Much
More informationVariable Speed Drives
Technical Note 3 Variable Speed Drives & Single Wire Earth Return (SWER) Supplies www.zener.com.au Note: This article is intended as a guide only. It is the responsibility of the installer to define and
More informationPower Factor Compensation System. Norelco NACB
Power Factor Compensation System Norelco NACB NACB POWER FACTOR COMPENSATION SYSTEM 2 NACB Power Factor Compensation System Table of contents Sivu Table of contents 2 General description 2 NACBR+L Wall-mounted
More informationBINDER Inc. North America. Scientific Products Pricelist 2010 Issue 2/10
BINDER Inc. North America Scientific Products Pricelist 2010 Issue 2/10 Product Selection chart LABORATORY EQUIPMENT 43KM A V H E T TF P Audible Visual Humidity Ethernet Temperature Timer functions Programable
More information