SEL-700G Generator and Intertie Protection Relays
|
|
- Spencer Joseph
- 6 years ago
- Views:
Transcription
1 SEL-700 enerator and Intertie Protection Relays SEL-700 ase Unit Vertical hassis Front Panel Large L isplay 4 Programmable Pushbuttons w/8 LEs 8 Target LEs (6 Programmable) Operator ontrol Interface EI-232 Port Processor and ommunications ard EI-232 Port Multimode (ST ) Fiber-Optic Serial Port IRI- Time ode Power Supply ard with 2 I, 3 O SELERTOR QuickSet SEL-5030 Software User onfigurable Labels Instruction Manual (printed manual available) Synchrophasors with Protocol Protocols Modbus RTU SEL SII and ompressed SII SEL Fast Meter, Fast Operate, Fast SER SEL Fast Message Ymodem File Transfer SEL MIRRORE ITS Event Messenger Options 7000 Provides 3 Expansion Slots for Optional ards. 7001, 700W, and 700T Provide 2 Expansion Slots for Optional ards includes Slot Z 4 I / 3 VI card includes Slot Z 4 I / 3 VI and Slot E 2 VI cards 7001 includes Slot Z 4 I / 3 VI and Slot E 3 IE cards includes Slot Z 4 I / 3 VI and Slot E 3 I / 2 VI cards 700T includes Slot Z 1 I and Slot E 3 I / 4 VI cards 700T+ includes Slot Z 4 I / 3 VI and Slot E 3 I / 4 VI cards 700W includes Slot Z 3 IZ and Slot E 3 IE cards onversion Information Table SEL-300 Model SEL-300 Features Suggested Equivalent SEL-700 Model 03000XXXXXXXXXXX asic enerator Elements 03001XXXXXXXXXXX asic enerator Elements + ifferential 03002XXXXXXXXXXX asic enerator Elements + Sync heck 03003XXXXXXXXXXX asic enerator Elements + Sync + ifferential 07000XXXXXXXXXXXXXX (7000 Model) 07001XXXXXXXXXXXXXX (7001 Model) 07000XXXXXX74XXXXXX (7000+ Model) 07001XXXXXX7(2/6)XXXXX (7001+ Model) Note: For 19" rack-mount installation, use bracket PN For details see Mounting SELETOR Part Number: Model 7000 Model, asic enerator Protection (87N, REF, 49T, 50/51, 51V/, 46, F, 27/59, 24, 64F, 67/N, 32, 40, 60LOP, 81/81R)* Model, asic enerator Protection plus en 25, 64, 21, 78, uto Synchronizer* 7001 Model, asic enerator Protection plus 87, 21, 78 * Model, asic enerator Protection plus 87, en 25, 64, 21, 78, uto Synchronizer* 700T Model, Intertie Protection (50/51, F, 67P/Q/, Tie 25, 27/59, 32, 60LOP, 81/81R)* 700T+ Model, Intertie and enerator Protection, uto Synchronizer* T 7 T 7 opyright SEL of 9 WI-8147
2 700W Model, Wind enerator Protection (ual feeder 50/51, F, 64F) * SELET Power Supply with I/O Option Slot Power Supply Vdc, Vac, 50/60 z (SELET PSIO / 2 I / 3 O) 125 Vdc/Vac igital 24 Vdc/Vac igital 48 Vdc/Vac igital 110 Vdc/Vac igital 220 Vdc/Vac igital 250 Vdc/Vac igital Power Supply Vdc/Vac igital Vdc (SELET PSIO / 2 I / 3 O) 24 Vdc/Vac igital 48 Vdc/Vac igital 110 Vdc/Vac igital 220 Vdc/Vac igital 250 Vdc/Vac igital W SELET Processor oard Option Slot ll Slot options include EI-232 Front, IRI-, Fiber Optic Serial Multimode ST, SEL Processor oard SII, ompressed (SELET PU/OM) SII, Fast Meter, Fast Operate, Fast Message, MIRRORE ITS, and Modbus RTU 0 SELET Ethernet/Rear Serial Options Slot Ethernet/Rear Serial No Ethernet, EI- Options 232 Rear No Ethernet, EI- 485 Rear Single 10/100ase-T Ethernet, EI-232 Rear* Single 10/100ase-T Ethernet, EI-485 Rear* Single 100ase-FX MM L Ethernet, EI-232 Rear* ual 10/100ase-T Ethernet, EI-232 Rear* opyright SEL of 9 WI-8147
3 ual 100ase-FX MM L Ethernet, EI-232 Rear* 8 SELET Protocols Slot Protocols Standard 0 Standard plus IE (requires Ethernet)* Standard plus NP3* Standard plus NP3 plus IE (requires Ethernet)* SELET I/O ard Option Slot No ard Empty 0 X 3 igital / 4 igital Output / m nalog Output (SELET 3 I / 4 O / 1 O) (1) 4 igital / 4 igital Output (SELET 4 I / 4 O) 125 Vdc/Vac I, 24 Vdc/Vac I, 48 Vdc/Vac I, 110 Vdc/Vac I, 220 Vdc/Vac I, 250 Vdc/Vac I, 125 Vdc/Vac I, 24 Vdc/Vac I, 48 Vdc/Vac I, 110 Vdc/Vac I, 220 Vdc/Vac I, 250 Vdc/Vac I, 125 Vdc/Vac I, Fast igh urrent Interrupting 24 Vdc/Vac I, Fast igh urrent Interrupting 48 Vdc/Vac I, Fast igh urrent Interrupting opyright SEL of 9 WI-8147
4 110 Vdc/Vac I, Fast igh urrent Interrupting 220 Vdc/Vac I, Fast igh urrent Interrupting 250 Vdc/Vac I, Fast igh urrent Interrupting 8 igital Output (SELET 8 O) 4 nalog / 4 nalog Output ±20 m or ±10 V (SELET 4 I / 4 O) Jumper Selectable* (2) 2 X 6 X Serial ommunication ard (SELET EI /485)* 8 igital 125 Vdc/Vac* 3 (SELET 8 I) 4 igital / 3 igital Output (2 Form, 1 Form ) (SELET 4 I / 3 O) 24 Vdc/Vac* 3 48 Vdc/Vac* Vdc/Vac* Vdc/Vac* Vdc/Vac* Vdc/Vac I, 24 Vdc/Vac I, 48 Vdc/Vac I, 110 Vdc/Vac I, 220 Vdc/Vac I, 250 Vdc/Vac I, SELET I/O ard Option Slot No ard Empty 0 X 3 igital / 4 igital Output / m nalog Output (SELET 3 I / 4 O / 1 O) (1) 125 Vdc/Vac I, 24 Vdc/Vac I, 48 Vdc/Vac I, 110 Vdc/Vac I, 220 Vdc/Vac I, opyright SEL of 9 WI-8147
5 4 igital / 4 igital Output (SELET 4 I / 4 O) 250 Vdc/Vac I, 125 Vdc/Vac I, 24 Vdc/Vac I, 48 Vdc/Vac I, 110 Vdc/Vac I, 220 Vdc/Vac I, 250 Vdc/Vac I, 125 Vdc/Vac I, Fast igh urrent Interrupting 24 Vdc/Vac I, Fast igh urrent Interrupting 48 Vdc/Vac I, Fast igh urrent Interrupting 110 Vdc/Vac I, Fast igh urrent Interrupting 220 Vdc/Vac I, Fast igh urrent Interrupting 250 Vdc/Vac I, Fast igh urrent Interrupting 8 igital Output (SELET 8 O) 4 nalog / 4 nalog Output ±20 m or ±10 V (SELET 4 I / 4 O) Jumper Selectable* (2) X 6 X 10 RT (SELET 10 RT)* 9 X 8 igital (SELET 8 I) 4 igital / 3 igital Output (2 Form, 1 Form ) (SELET 4 I / 3 O) 125 Vdc/Vac* 3 24 Vdc/Vac* 3 48 Vdc/Vac* Vdc/Vac* Vdc/Vac* Vdc/Vac* Vdc/Vac I, 24 Vdc/Vac I, opyright SEL of 9 WI-8147
6 48 Vdc/Vac I, 110 Vdc/Vac I, 220 Vdc/Vac I, 250 Vdc/Vac I, SELET I/O ard Option Slot E No ard Empty 0 0 X 3 igital / 4 igital Output / m nalog Output (SELET 3 I / 4 O / 1 O) (1) 4 igital / 4 igital Output (SELET 4 I / 4 O) 125 Vdc/Vac I, 24 Vdc/Vac I, 48 Vdc/Vac I, 110 Vdc/Vac I, 220 Vdc/Vac I, 250 Vdc/Vac I, 125 Vdc/Vac I, 24 Vdc/Vac I, 48 Vdc/Vac I, 110 Vdc/Vac I, 220 Vdc/Vac I, 250 Vdc/Vac I, 125 Vdc/Vac I, Fast igh urrent Interrupting 24 Vdc/Vac I, Fast igh urrent Interrupting 48 Vdc/Vac I, Fast igh urrent Interrupting 110 Vdc/Vac I, Fast igh urrent Interrupting opyright SEL of 9 WI-8147
7 220 Vdc/Vac I, Fast igh urrent Interrupting 250 Vdc/Vac I, Fast igh urrent Interrupting 8 igital Output (SELET 8 O) 4 nalog / 4 nalog Output ±20 m or ±10 V (SELET 4 I / 4 O) Jumper Selectable* (2) 8 igital (SELET 8 I) 4 igital / 3 igital Output (2 Form, 1 Form ) (SELET 4 I / 3 O) 3-Phase urrent / 3-Phase Voltage (300 Vac) and Vsync (SELET 3 I / 4 VI) X 0 6 X 125 Vdc/Vac* Vdc/Vac* Vdc/Vac* Vdc/Vac* Vdc/Vac* Vdc/Vac* Vdc/Vac I, 24 Vdc/Vac I, 48 Vdc/Vac I, 110 Vdc/Vac I, 220 Vdc/Vac I, 250 Vdc/Vac I, 1 mp Phase T mp Phase T Phase urrent, Vsync, and Vn (300 1 mp Phase (6) Vac) (SELET 3 I / 2 VI) 3-Phase urrent (SELET 3 IE) Vsync and Vn (300 Vac) (SELET 2 VI) 5 mp Phase (6) mp Phase (3) mp Phase (3) Vac Maximum (7) opyright SEL of 9 WI-8147
8 SELET I/O ard Option Slot Z 3-Phase urrent / Neutral 8 1 urrent / 1 mp Phase, 1 3-Phase Voltage mp Neutral (4) (300 Vac) (SELET 4 I / 3 VI) 5 mp Phase, mp Neutral (4) 1 mp Phase, mp Neutral (4) 5 mp Phase, mp Neutral (4) 3-Phase urrent (SELET 3 1 mp Phase W 8 3 IZ) 1-Neutral urrent (SELET 1 I) onformal oat 5 mp Phase W mp Neutral (5) T mp Neutral (5) T 8 8 None 0 onformal oated ircuit oards* 1 ccessories Literature Printed Instruction Manual (8) P M * dditional ost (1) Only one (1) 3 I /4 O / 1 O card per chassis. (2) Only one (1) 4 I / 4 O card per chassis. (3) Only available with 7001 and 700W models. (4) Only available with 7000, 7000+, 7001+, 7001, and 700T+ models. (5) Only available with 700T models. (6) Only available with models. (7) Only available with models. (8) One complimentary printed instruction manual is available upon request with each product purchased. NOTES: - ase unit includes slots, (EI-232), Z, MI, and Front EI-232 Port. - ownload SELERTOR QuickSet SEL-5030 software for free at SELERTOR QuickSet on (503001WX4) is available upon request. - configuration kit is provided for the front panel configurable labels (packaged in the shipping box). For additional kits, order SEL part number Order external powered RT module SEL-2600 or external powered RT module SEL-2600 using WI-5997 to interface remote external resistive temperature devices (RT) or use internal RT inputs option in Slot. - The SEL-700 can be ordered with a manual. - The SEL-700 option cards are orderable separately for field installation. Use WI-5932 and contact your SEL representative to order option cards. - For SEL-700 Mounting ccessories including adapter plates,dust protectors, etc go to - The protocols SNTP and Modbus TP are included in the STNR offering with Ethernet Option. - If 64F (Field round) Protection is desired, order Field round Module SEL-2664 (WI-5752) with SEL-807 (WI-4132) Fiber-optic cable. dditionally, if using SEL-2664 on port 3 order SEL-2812Mx (WI-4600). opyright SEL of 9 WI-8147
9 2350 NE opkins ourt - Pullman, W US Phone: Fax: opyright SEL of 9 WI-8147
SEL-710 Motor Protection Relay
SEL-710 Motor Protection Relay SEL-710 ase Unit Vertical hassis Front Panel Large L isplay 4 Programmable Pushbuttons w/8 LEs 8 Target LEs (6 Programmable) Operator ontrol Interface EI-232 Port Processor
More informationSEL-2414 Transformer Monitor
SEL-2414 Transformer Monitor SEL-2414 Base Unit Vertical Chassis Front Panel Large LCD Display 4 Programmable Pushbuttons w/leds 7 Programmable LEDs Operator Control Interface EIA-232 Port Processor and
More informationFirmware. Conformal Coat. Secondary Input Voltage. Secondary Input Current. Extra Inputs/Outputs X A. Communications Interface D E F
SL-651R Traditional Retrofit Recloser ontrol (14-pin) with utomatic Network Reconfiguration, Harmonic nalysis, Six Voltage Inputs, Z Settings, Power Quality Monitoring, 8 Settings Groups, Template Storage,
More informationSEL-2411 Programmable Automation Controller
SEL-2411 Programmable Automation Controller - Chassis - Processor and Communications Board - Front Panel - EIA-232 Port - LCD Display - IRIG-B Time Code - Operator Control Interface - Power Supply with
More informationPower Quality and Recording Field Upgrade Available SEL-734, Standard Power Quality, 32 MB Memory SEL-734P, Advanced Power Quality, 128 MB Memory*
SEL-734 Advanced Metering System with ANSI and IEC Class 0.2 Accuracy Standard with: ANSI Type 2 Optical Port, 2 Rear EIA-232 Ports, ACSELERATOR QuickSet SEL-5030 Software, Modbus RTU Communications Protocol,
More informationUSB Interface. Power Supply. Manual Raise/Lower Operators. Communications Port (Port 1) Communications Port (Port 2)
SEL-2431 Single-Phase Voltage Regulator Control, Two 120 Vac Voltage Inputs, Eight Contact Inputs (Two 120 Vac Programmable, Four 12 Vdc Self-Whetted Programmable, and Two Dedicated), Seven Contact Outputs
More informationSerial Communication Card (SELECT EIA-232/485) Part Number Serial Communication 9787LA0_ (1) Note: Slot C option only.
pbib`qfll`~êçë m~êíkìãäéêëñçêíüépbijtutjp~åçpbijtutjq lêçéêáåöfåñçêã~íáçå OPRMkbeçéâáåë`çìêí mìääã~åit^vvnspjrsmprp^ müçåéwhnkrmvkppoknuvm c~ñwhnkrmvkppoktvvm fåíéêåéíwïïïkëéäáååkåçã bjã~áäwáåñç]ëéäáååkåçã
More informationSELect I/O Cards Part Numbers for the SEL 710 5
SELect I/O Cards s for the SEL 710 5 Ordering Information OPRMkbeçéâáåë`çìêí mìääã~åit^vvnspjrsmprp^ müçåéwhnkrmvkppoknuvm c~ñwhnkrmvkppoktvvm fåíéêåéíwïïïkëéäáååkåçã bjã~áäwáåñç]ëéäáååkåçã Serial Communication
More information2 ms arc-flash protection and feeder relay in one platform
Feeder Protection Relay 2 ms arc-flash protection and feeder relay in one platform Combine light sensor inputs with high-speed overcurrent protection to achieve secure arc-flash protection in as fast as
More informationDCS Digital Control Expansion System
S Digital ontrol Expansion System 4 position Phoenix type connector for power supply. 2 LED s on the front indicating power. Internal backplane with system bus. Internal self-resetting fuses. General Description:
More informationFirmware. Control Cable Interface
SEL-651R-2 Recloser Control with Automatic Network Reconfiguration, Harmonic Analysis, Single-Phase Trip Capability, 6 Voltage Inputs, Power Quality Monitoring, 8 Settings Groups, Template Storage, SEL
More informationSEL-487B. A Powerful Solution for Busbar Differential Protection. Bus Differential and Breaker Failure Relay
Bus Differential and Breaker Failure Relay A Powerful Solution for Busbar Differential Protection Features and Benefits Select the for the differential protection of busbar systems with up to 18 terminals.
More information1280 Enterprise Series Programmable Color Touchscreen Weight Indicator/Controller
1280 nterprise Series 520 Panel Mount Standard Features 7-inch Touch-only Seven-inch, 800 x 480 pixel, graphical color display that adjusts for ambient light conditions Twelve-inch, 1280 x 800 pixel, graphical
More informationComprehensive protection for large, medium, and small generators
SEL-700G Generator Protection Relay Comprehensive protection for large, medium, and small generators Provide primary and backup generator protection with current, voltage, frequency, distance, power, and
More informationChapter. Specifications: In This Chapter...
Specifications: hapter PU Modules In This hapter... PU Specifications... PU General Specifications... ommunications Ports Specifications... Port Specifications (US)... Port Specifications (Serial)... US
More informationPLC CommuniCations In This Chapter...
PL ommunications In This hapter... Introduction... PL ommunication Ports Specifications... LE Status Indicators... Steps to Using the LIK PL ommunications... Typical ommunications pplications... W-: om
More informationMaximize process uptime with the SEL-patented motor thermal model.
SEL-710 Motor Protection Relay Maximize process uptime with the SEL-patented motor thermal model. Optimize motor performance with separate thermal models for the stator and rotor. Monitor stator and ambient
More informationBus Differential and Breaker Failure Relay. Advanced bus protection with built-in breaker failure detection
SEL-487B Bus Differential and Breaker Failure Relay Advanced bus protection with built-in breaker failure detection Protect busbars with up to 21 terminals using high-speed, low-impedance bus differential
More informationThe SEL-700G Generator Protection Relay is the newest member of the SEL-700 series platform. It combines the protection features of the proven
1 2 3 4 The SEL-700G Generator Protection Relay is the newest member of the SEL-700 series platform. It combines the protection features of the proven SEL-300G Generator Relay with the SEL-700 series platform
More informationA low-cost, economical solution for distribution feeder protection
SEL-351A Protection System A low-cost, economical solution for distribution feeder protection Achieve sensitive and secure fault detection using comprehensive protection functions. Track breaker status
More informationProtection, Automation, and Control System. Combine subcycle line protection with complete substation bay control
Protection, Automation, and Control System Combine subcycle line protection with complete substation bay control Subcycle distance protection minimizes damage and expensive repairs on transmission lines.
More informationHigh-speed transformer differential protection for up to five terminals
Transformer Protection Relay High-speed transformer differential protection for up to five terminals Advanced differential protection and three restricted earth fault (REF) elements minimize damage and
More informationProtect induction and synchronous motors with one relay.
SEL-710-5 Motor Protection Relay Protect induction and synchronous motors with one relay. Patented, accurate thermal protection improves motor availability for production. Synchronous motor protection
More information900MB Series. Analog Output Module. Four Analog Outputs. DC Current or DC Voltage. Description
900M Series Modbus/ nalog Output Module Outputs (2) Four nalog Outputs urrent or Voltage Isolation Four iscrete Outputs Outputs (4) Modbus Outputs (2) 10-36V or 24V Power 917/918M Multi-hannel nalog Output
More informationAdvanced distribution feeder solution with integrated protection, monitoring, and control
Protection System Advanced distribution feeder solution with integrated protection, monitoring, and control Achieve sensitive and secure fault detection using comprehensive protection functions. Keep track
More informationRTAC. SEL Real-Time Automation Controller. Integrate station control, a web-based HMI, and logging through one reliable system.
SEL-3530-4 Real-Time Automation Controller Integrate station control, a web-based HMI, and logging through one reliable system. Features and Benefits Integrated Security As with its bigger brother, the
More informationChapter. In This Chapter...
RX o-more! PU Specifications hapter In This hapter... The RX Platform... - RX o-more! PU ommon Specifications... - Memory Features... - PU Status Indicators... - Mode Switch Functions... - IP Switch Specifications...
More informationChapter. Accessories. In this Chapter...
ccessories hapter In this hapter... ccessories...- -more Micro Programming Software...- E-EOM Ethernet ommunication Module...- -SU -pin 0-degree ommunication Port dapter...- -SU -pin to Terminal lock dapters...-
More informationBus Differential and Breaker Failure Relay. Advanced bus protection with built-in breaker failure detection
SEL-487B Bus Differential and Breaker Failure Relay Advanced bus protection with built-in breaker failure detection Protect busbars with up to 21 terminals using high-speed, low-impedance bus differential
More informationBus Differential and Breaker Failure Relay. Advanced bus protection with built-in breaker failure detection
SEL-487B Bus Differential and Breaker Failure Relay Advanced bus protection with built-in breaker failure detection Protect busbars with up to 21 terminals using high-speed, low-impedance bus differential
More informationChapter. Protos X. Configuration. In This Chapter...
hapter Protos X onfiguration In This hapter... Protos X Software onfiguration Tool (PG-FGSW)... Protos X iscrete and nalog I/O Mapping... hapter : Protos X onfiguration 0 Protos X Software onfiguration
More information2 ms arc-flash protection and feeder relay in one platform
Feeder Protection Relay 2 ms arc-flash protection and feeder relay in one platform Directly monitor and control your system using the 5-inch, 800 480 color touchscreen display. Prevent insulation damage
More informationPower Series Transfer Switch
Power Frame Type losed Transition Power Series Transfer Switch 1600-5000 mps Power Series 1 of 5 utomatic Transfer Switch 1600 5000, up to 600V, 50/60 Hz 3 or 4 poles NEM 1 or 3R losed Transition UL1008
More informationChapter. Getting Started. In this Chapter...
Getting Started hapter In this hapter... Introduction...-2 onventions Used...- What s in the ox?...- Getting Started...- efore You egin......- Step - Install onfiguration Software...- Step 2 - Launch onfiguration
More informationSEL-2440 Discrete Programmable Automation Controller
Discrete Programmable Automation Controller Complete System for Control and Monitoring Rack Panel Surface DIN Rail 32 Inputs 16 Outputs 4 Ports (Standard) Major Features and Benefits Fast and Powerful
More informationM1Gxxxx Series Modular Tap Installation Guide
GN POS NEG M1Gxxxx Series Modular Tap To deploy the M1Gxxxx modular tap system into your network, simply: arefully unpack and inspect the tap modules and system chassis Insert and fully seat the M1Gxxxx
More informationPSSU/A Control Unit Installation Instructions
elease0 /0 Ver.. Installation Instructions: PSSU/ ontrol Unit PSSU/ ontrol Unit Installation Instructions INTOUTION The PSSU/ control unit is designed to be used with Tapeswitch pressure sensitive sensors,
More informationPSSU/A2 Control Unit Installation Instructions
PSSU/ Unit Installation Instructions INTROUTION The PSSU/ control unit is designed to be used with Tapeswitch pressure sensitive sensors, such as ribbon switches, sensing edges, bumpers, and presence-sensing
More informationCVH Slot Media Converter Chassis Quick Installation Guide
CVH-2000 14-Slot Media Converter Chassis Quick Installation Guide Ver. 1.2-1305 Table of Contents 1. INTRODUCTION... 1 1.1. FEATURES... 1 1.2. PACKAGE CONTENTS... 1 2. HARDWARE DESCRIPTION... 2 REAL PANEL...
More informationSECTION5AE/CE SERIES INDUSTRIAL CONTROL TRANSFORMERS
SETION5AE/E SERIES INDUSTRIAL ONTROL TRANSFORMERS FEATURES Integrally molded terminal blocks with combination slotted/phillips screws. Isolation barriers protect against arc over while able to accommodate
More informationPower Series Transfer Switch
Service Entrance Rated Power Frame Type losed Transition Power Series Transfer Switch 1000-5000 mps Power Series 1 of 5 utomatic Transfer Switch, 100% Service Entrance Rated 1000 5000, up to 600V, 50/60
More informationMACH100 19" Industrial Workgroup Rack-Mount Switches
MACH100 19" Industrial Workgroup Rack-Mount Switches Fast Ethernet Uplink Ports, Gigabit Ethernet Uplink Ports, and 10 Gigabit Uplink Ports The MACH100 series of switches are offered in versions with 8,
More informationChapter. Maintenance and. Troubleshooting. In this Chapter...
hapter Maintenance and Troubleshooting In this hapter... Introduction...- Updating Firmware...- Load Firmware Message...- Reboot LE isplay...- Reset Factory efaults...- Reset ommunications to Factory efault...-
More informationD90 Plus. Sub-cycle distance protection and advanced automation controller. Multilin
Key Benefits 90 Plus Sub-cycle distance protection and advanced automation controller Secure sub-cycle distance protection to improve system stability and increase line loading True VT filter improves
More informationReal-Time Automation Controller (RTAC) Powerful, reliable, and secure multifunction controller
SEL-3530 Real-Time Automation Controller (RTAC) Powerful, reliable, and secure multifunction controller Versatile RTAC operates as a supervisory control and data acquisition (SCADA) remote terminal unit
More informationBITRONICS 878 DIOD Product Description BITRONICS 878 DIOD DISTRIBUTED INPUT/OUTPUT DEVICE
BITRONICS 878 DIOD Product Description BITRONICS 878 DIOD DISTRIBUTED INPUT/OUTPUT DEVICE This page intentionally left blank 2 l BITRONICS 878 DIOD APPLICATION NOTE 878 Distributed Input/Output Device
More informationProtect induction and synchronous motors with one relay
SEL-710-5 Motor Protection Relay Protect induction and synchronous motors with one relay Patented, accurate thermal protection improves motor availability for production. The 5-inch, 800 480 color touchscreen
More informationSPACE REQUIREMENTS AND PLANNING GUIDE
SPE REQUIREMENTS N PLNNING GUIE Width Measurements MX-F10 MX-F11 MX-R15 MX-R12 E F G H I J L Note: In addition to the above dimensions, allow three feet of space on all sides for consumable replenishment,
More informationNexus Next Generation Power Meter for Critical Energy Circuits. Advanced Metering and Communication
Nexus 1500+ Next Generation Power Meter for ritical Energy ircuits www.electroind.com dvanced Metering and ommunication onstant alibration rchitecture Provides Highly Stable Readings, as the Meter Self-calibrates
More informationL Series. UL Recognized CSA Certified VDE Approved. Specifications. L Series. Power Inlet Filters & Power Entry Modules
ual onfiguration Power ntry Module UL Recognized S ertified V pproved L / L Power entry module with switch or fuse or capability and high performance filtering see the P Series on page 9 Two element circuit
More informationProtection, Automation, and Bay Control System. Advanced feeder protection and complete substation bay control in one economical system
SEL-451 Protection, Automation, and Bay Control System Advanced feeder protection and complete substation bay control in one economical system Customize distribution protection using multiple instantaneous,
More informationLightweight and flexible recloser control for single-phase applications
SEL-35S Kestrel Single-Phase ecloser Control Lightweight and flexible recloser control for single-phase applications Plug-and-work operation with popular single-phase reclosers simplifies new and retrofit
More informationPower Series Transfer Switch
Power Frame Type Open and Delayed Transition Power Series Transfer Switch 2000-5000 mps Power Series 1 of 5 utomatic Transfer Switch 2000 5000, up to 600V, 50/60 Hz 3 or 4 poles NEM 1 or 3R Open with Inphase
More informationPowerFlex 523 AC Drive
PowerFlex 523 A rive PowerFlex 523 A drives are designed to help reduce installation and configuration time with an innovative modular design while providing just enough control for your application. These
More informationGCR2000xx User Manual. User Manual. GCR2000xx 10/100/1000Mbps to 1000Base-XX Fibre Optic Media Converter. Version 1.
User Manual GR2000xx 10/100/1000Mbps to 1000ase-XX Optic Media onverter Version 1.1 September 2010 aution Electronic ircuit devices are sensitive to static electricity. Dry weather conditions or walking
More informationAdvanced Line Differential Protection, Automation, and Control System. Combine subcycle line protection with traveling-wave fault locating
Advanced Line Differential Protection, Automation, and Control System Combine subcycle line protection with traveling-wave fault locating Subcycle differential and distance protection minimizes damage
More informationSPACE REQUIREMENTS AND PLANNING GUIDE
SPE REQUIREMENTS N PLNNING GUIE Width Measurements L Height from platen glass with document feeder open MX-F10 MX-F11 MX-R18 E F G H I J Note: In addition to the above dimensions, allow three feet of space
More informationEXN3000 Storage Expansion Unit Installation and Setup Instructions
IBM System Storage EXN3000 Storage Expansion Unit Installation and Setup Instructions G52-1345-03 Notices Mail comments to: IBM orporation Attention epartment GZW 9000 South Rita Road Tucson, AZ 85744-0001
More informationwww. ElectricalPartManuals. com Protective Relays HIGHLIGHTS PROTECTIVE FUNCTIONS ixp-420 Transformer Protection Relay
Protective Relays Electrical Apparatus ixp-420 Transformer Protection Relay 165-420 Figure 1: Edison Idea Relay The ixp-420 is a member of Cooper Power Systems Edison Idea line of protective relays. The
More informationPT-7728/7828 Quick Installation Guide
PT-7728/7828 Quick Installation Guide Moxa PowerTrans Switch Edition 9.0, April 2017 Technical Support Contact Information www.moxa.com/support Moxa Americas: Toll-free: 1-888-669-2872 Tel: 1-714-528-6777
More informationProduct Sheet ECO. Types ECG, AMF Technical data. product sheet eco ecg-amf - technical data gb v1.0.docx
ECO Types ECG, AMF Technical data Product overview ECO ECG and ECO AMF are microprocessor controlled devices for use in low voltage single genset applications for standby power generation. The front-side
More informationMore Precision. scancontrol // 2D/3D laser scanner (laser profile sensors)
More Precision scanontrol // 2D/3D laser scanner (laser profile sensors) scanontrol 27x gapontrol 27x1 Technical details and versions - z-axis up to 3mm - x-axis up to 148mm - Profile frequency up to 4,Hz
More informationVS510SZ Hot Sheet. System Model # VSP-VS510SZ-DCAH Software Version # 36 EPN # Base PCBA - PN PCB VS500Z - PN Rev C or D
VS510SZ Hot Sheet System Model # VSP-VS510SZ-DAH Software Version # 36 EPN # 1801 Base PBA - PN 54372-01 PB VS500Z - PN 22972 Rev or D Base Panels Serial Standard PN 53189 Template used: 40600_E.pdf 07/05/2006.pdf
More informationNexus Next Generation Power Quality Meter for Critical Energy Circuits. Advanced Metering and Communication
Nexus 1500+ Next Generation Power Quality Meter for ritical Energy ircuits www.electroind.com dvanced Metering and ommunication onstant alibration rchitecture Provides Highly Stable Readings, as the Meter
More informationPLC - LonWorks Programmable Fieldbus Controller 16-bit CPU
88 PL - LonWorks Programmable Fieldbus ontroller 16-bit PU Fieldbus connection 231 Series (MS) LonWorks STTUS IOM USR 01 02 24V 0V + + Status voltage supply -System -Power jumper contacts Supply Supply
More informationUniversal SAS and ACP Cabling Guide
IM System Storage N series Universal SS and P abling Guide G27-3919-04 ontents Preface................................ v Supported features............................. v Websites................................
More informationNokeval. FD100 series. User Manual
Nokeval FD100 series User Manual Contents Document information... 2 FD100A4 and FD100A6 field displays... 3 Power supply connection... 4 Configuring... 5 Specifications... 7 Document information Device
More informationOverview. Features CHAPTER
CHAPTER 2 This chapter provides these topics that describe the Catalyst 2955 switch, hereafter referred to as the switch. Features, page 2-1 Front-Panel Description, page 2-3 Rear-Panel Description, page
More informationVS501Z-4K Hot Sheet. System Model # VSP-VS501Z-CCAJ Software Version # 35 EPN # Base PCBA - PN PCB VS500Z - PN Rev C or D
VS501Z-4K Hot Sheet System Model # VSP-VS501Z-AJ Software Version # 35 EPN # 1801 Base PBA - PN 54357-01 PB VS500Z - PN 22972 Rev or D Base Panels Mini PN 52144 Lite Digital PN 54094 Lite Duplex PN 51676
More informationChapter. System Design and Configuration. In This Chapter:
System esign and onfiguration hapter In This hapter: L0 System esign Strategies... Module Placement... alculating the Power udget... Local Expansion I/O... Expanding L0 I/O... Network onnections to Modbus
More informationIndex A B C D. i-1
ccumulating Fast Timer instruction, ccumulating Timer (TMR) instruction, ccumulator, ccumulator Instructions, liases, nalog Ioxes, 0 pprovals, SII onversion Table, G- SII In/Out and PRINT, SII Instructions,
More informationPanel Meter Economical Panel Meter for Process, Temperature and Electrical Measurement
8 DN Multisignal Panel Meter Economical Panel Meter for Process, Temperature and Electrical Measurement DP20 TM DP20 meter shown smaller than actual size. OME s new multisignal panel meter delivers high-performance
More informationThermal-Magnetic / Magnetic Only Molded Case Circuit Breakers Introduction
Thermal-Magnetic / Magnetic Only Molded ase ircuit reakers Introduction Table 8: reakdown of Typical atalog Number L 3 6 050 V 2100 reaker amily Y - mpere rame - 100 mpere rame K - 250 mpere rame L - 400
More informationChapter. Specifications. In this Chapter...
Specifications hapter In this hapter... vailable Models... - E-SML-RN and E-SML-R Specifications... - E-SML and E-TL Specifications... - E-TL, E-TL and E-TL Specifications... - E-SML-RN, E-SML-R, E-SML
More informationSEL-2030 Communications Processor
SEL-2030 Communications Processor Integrate New and Existing Substations Create integrated systems that use substation hardened equipment to collect data from station IEDs, process and concentrate collected
More informationVersion 7.7x Release Notes
GE Grid Solutions UR Family Version 7.7x Release Notes GE Publication Number: GER-4834A opyright 2018 GE Multilin Inc. Overview This document contains the release notes for firmware and software versions
More informationUNSIGNED HARDCOPY NOT CONTROLLED
UNSIN ROPY NOT ONTROLL ardware ngineering No. LMS -0 Subject: PPROV Y STTUS PURPOS Manager, ardware ngineering Maintenance Revision efines the requirements for electrical connector keying. Two areas are
More informationSEL-2411P Pump Automation Controller Data Sheet
SEL-2411P Pump Automation Controller Complete System for Control and Monitoring SELECT I/O Family of Cards Analog I/O Including ac and dc Digital I/O High Reliability, Low Price Ten-Year, Worldwide Warranty
More informationSpecifications. Inputs. Outputs. Recip Velocity. Signal. Front Panel LEDs OK LED. Input Impedance TX/RX LED. Sensor Compatibility.
3500/70M Recip Impulse/Velocity Monitor ently Nevada sset ondition Monitoring Description The 3500/70M Recip Impulse Velocity / Monitor is a 4-channel monitor that can be used as part of the reciprocating
More informationPQube 3. Power Quality, Energy & Environment Monitoring. New Low-Cost, High-Precision
New Low-Cost, High-Precision Power Quality, Energy & Environment Monitoring PQube 3 Power Quality Class A Energy Revenue Grade class 0.2s Accuracy Additional AC, DC, and Environment Sensor Channels World
More informationTripp Lite Network-Grade Power Distribution Units (PDUs)
T N L P P L T O N U L L T N # 9 5-3 0 8 4 Tripp Lite Network-rade Power istribution Units (PUs) Tripp Lite Network-rade PUs are extremely reliable multiple-outlet strips that distribute power from a UPS
More informationxin 4, xio 4x4 and xout 4
Data Sheets xin 4, xio 4x4 and xout 4 T +1.425.778.7728 F +1.425.778.7727 www.symetrix.co xin 4 xin 4 Audio input (A/D) expander for SymNet systems that capitalizes on the surplus DSP of a Dante-enabled
More informationEmbedded EtherNet/IP Option Card for DriveLogix 5730 Controllers
Installation Instructions Embedded EtherNet/IP Option ard for DriveLogix 5730 ontrollers!!! TTENTION: To avoid an electric shock hazard, verify that the voltage on the bus capacitors has discharged before
More informationAPR64(Rackable) APR64P (Portable)
APR64(Rackable) APR64P (Portable) Digital Fault Recorder Sequence Event Recorder Trend mode Recorder - Up to 96 analog and 1536 digital channels - Accuracy: 0.1%, sampling rate 6400Hz - Storage in internal
More informationChapter. Getting Started. In This Chapter...
Getting Started hapter In This hapter... bout This Manual... onventions Used... Introduction... Protos X I/O System omponents... Protos X I/O System Example... hapter : Getting Started 0 bout This Manual
More informationYokogawa Temperature Controllers. Weschler Premo BarGraph Meter /Controller SPECIFICATIONS SPECIFICATIONS ORDERING INFORMATION
ONTROLLERS Weschler Premo argraph Meter /ontroller ontinued from previous page Digital Display Range: -199999 to 999999 Decimal Point: Five positions, front panel selectable Update Rate: 3 to 10 times
More informationFVT Slot Media Converter Chassis w/ Redundant Power User Manual
FVT-4000 10-Slot Media Converter Chassis w/ Redundant Power User Manual Ver. 1.00-0609 Table of Contents 1. INTRODUCTION... 1 1.1. FEATURES... 1 1.2. PACKAGE CONTENTS... 2 2. HARDWARE DESCRIPTION... 3
More informationNpefm!681F! !!!681F!Gjcfspqujd!Usbotdfjwfs! Gjcfspqujd!Ofuxpsl!Tpmvujpo!! Model 570E Features. The Fiberoptic Communications Specialists
!!!681F!Gjcfspqujd!Usbotdfjwfs! Gjcfspqujd!Ofuxpsl!Tpmvujpo!! The Fiberoptic Communications Specialists The Model 570E offers high-speed serial communication to meet the challenging needs of distribution
More informationPower Series Transfer Switch
ypass Isolation ontactor Type losed Transition Transfer Switch 100-1200 mps 1 of 5 ypass Isolation Transfer Switch 100 1200, up to 600V, 50/60 Hz 3 or 4 poles NEM 1 or 3R losed Transition UL1008 Listed
More informationType SDR reclosers plus controllers and type B-2 recloser bypass switch assembly usa.siemens.com/mediumvoltage
Overhead solutions Type SDR reclosers plus controllers and type B-2 recloser bypass switch assembly usa.siemens.com/mediumvoltage Overhead switching products Brochure Your outdoor overhead distribution
More informationControlLogix PLC Revision Release List Rockwell Automation Certificate No.: 968/EZ /16
Release List ertificate No.: 968/EZ 536.02/16 SIL 2 Listed omponents IE 61508:2010 1756-RM001N-EN-P ontrollogix SIL 2 Safety Reference Manual NA NA 968/M 338.17/16 1756-A4 4 Slot ontrollogix hassis NA
More informationData Sheet: Model 5200 Controller
Description Programmable automation controller with integrated 0/00 -Bit thernet communications. wo asynchronous communications ports (wo RS-232 or ne RS-232 + ne RS-485) Up to 24 odular I/ bays n-board
More informationPROTECTION RELAYS THE ULTRA LINE NUMERICAL MULTIFUNCTION INTELLIGENT DEVICE FOR PROTECTION, SUPERVISION, METERING AND CONTROL
MICROPROCESSOR PROTECTION RELAYS THE ULTRA LINE NUMERICAL MULTIFUNCTION INTELLIGENT DEVICE FOR PROTECTION, SUPERVISION, METERING AND CONTROL MICROELETTRICA SCIENTIFICA MANUFACTURES A COMPLETE RANGE OF
More informationDigital Lighting Systems, Inc.
igital Lighting Systems, Inc. -MPW our hannel MX5 TRI / SR Trigger oard MX5 compatible -MPW USR'S MNUL -UM 0- Low Voltage Wiring Methods igure 4 M Network Ports onnections. uttom view 8 to V / 00 M rom
More informationAnalog input module. Data sheet. for MULTICAL 603
Data sheet Analog input module for MULTICAL 603 Two analog inputs, selectable as 0...20mA or 0...10V Individual scaling of measuring ranges Individual setup of measuring unit and decimal point Selectable
More informationPower Xpert Multi-Point Meter Quick Start Guide
Information ooklet I150001E Power Xpert Multi-Point Meter ontents Description Page Product Overview.... 2 Ordering Information.... 2 Material Selection Example.... 4 Meter ase.... 5 Meter ase - ssembly....
More information4-Pole Relay. 2 Coil. [V] Hz A1 A2 60 Hz A24 A1 A20 A2
ulletin - Product Overview/Product Selection ulletin - Industrial Relay ontact cartridges convertible from.o. to.. and vice versa EM V coils Pneumatic timing unit Solid-state timing unit Overlap contacts
More informationEL2000 Mach 3 Hot Sheet
EL2000 Mach 3 Hot Sheet System Model # E2P-EL2000M3-YCAH Software Version # 28 EPN # 2130 ase PCA - PN 53834-03 PC EL2000 PN 22896 Rev ase Panels ML900 PN 52654 ML700 PN 52649 ML400 PN 52684 Template used:
More informationSIL-A. Overcurrent and Earth Fault Relay for Primary and Secondary Distribution. Main characteristics
SIL-A Overcurrent and Earth Fault Relay for Primary and Secondary Distribution Main characteristics The SIL-A is an overcurrent and earth fault protection relay for primary and secondary distribution with
More informationMultiTrode MTIC & MTRIC. Indicator & Remote Indicator Controllers
MultiTrode MTI & MTRI Indicator & Remote Indicator ontrollers Page of 6 MTI / MTRI Manual R MTI Indicator ontroller Four ctuation elays: Method of Operation: Used to average out wave action and for other
More information