MICROCOMPUTER CONTROL CENTER PART NO. FOR

Size: px
Start display at page:

Download "MICROCOMPUTER CONTROL CENTER PART NO. FOR"

Transcription

1 RENEWAL PARTS CENTRIFUGAL LIQUID CHILLERS Supersedes: See Back Cover Form RP3 (1197) MICROCOMPUTER CONTROL CENTER PART NO. FOR ELECTROMECHANICAL STARTER, SOLID STATE STARTER AND TURBO-MODULATOR APPLICATIONS 28455A

2 ITEM DESCRIPTION FIG. NO QTY. PART NUMBER 1 Relay (1R) Transformer Fuse, 5 AMP Fuse 15 AMP Fuse Holder Control, Micro Board (Note 2) /-001/ Control, Power Supply Control, Digital Input Control, Relay Board - Production until 8/ Superseded by Fastener, Pawl Adj Keypad (Standard) (Simplified Chinese Language) (Traditional Chinese Language) Display 3, 4, , Note 3 13 Swtich, Rocker Suppressor Control, TM II Interface (Turbo-Modulator Apps. Only) Cable, Fiber Optic Current Setpoint (Turbo-Modulator Apps. Only) Cable, Fiber Optic Temperature Setpoint (Turbo-Modulator Apps. Only) Control, Current Module CM-2 (Electro-Mechanical Starter App. Only) Diode Bridge (Electro-Mechanical Starter App. Only) Resistor, Variable (Electro-Mechanical Starter App. Only) Control, Logic 7L (Solid State Starter App. Only) Control, Logic 14L (Solid State Starter App. Only) Control, Logic 26L (Solid State Starter App. Only) Control, Logic 33L (Solid State Starter App. Only) Control, Remote Reset (Customer Option) 1 Note Card File (Customer Option) IC, Real Time Clock U EPROM U Table 1 29 Transducers (Note 4) Condenser R R R11/R R11/R123 (VSD application only) Evaporator R R R11/R Oil Pressure (Low Side) R R R11/R Oil Pressure (High Side) R R R11/R Purge Pressure R (Low Pressure Purge Unit) R R11/R Purge Pressure R11/R (Pump-Assisted High Pressure Purge Unit) Oil Pressure (High Side) Used On R Monoshell Retrofits Only, Requires R11/R Special EPROM or -011 or -012 (Refer to Table 1) 30 Thermistors Entering Chilled Water Temp Leaving Chilled Water Temp Entering Condenser Water Temp Leaving Condenser Water Temp

3 FORM RP3 30 Thermistors Entering and Leaving Chilled and Condenser Water Temp (Cont d.) Thermistor with Threaded Cap Water Sensor Well with Threaded Top Oil Temperature Discharge Temperature Cable, Ribbon Micro Board J Cable, Ribbon Relay Board J Cable, Ribbon Display 3, 4, Cable, Ribbon Digital Input Board J Cable, Ribbon Micro Board J Voltage Transient Protection Module* for Micro Board RS-485 Serial Port (only used in units equipped with ISN FAX-4500 BAS connected to RS-485 Serial Port TB7) * If this Module is being installed for the first time, order kit # Kit includes module and Installation Instructions Kit, Retrofit Simplified (Chinese Language display) (also see Fig. 6) Kit, Retrofit Traditional (Chinese Language display) (also see Fig. 6) NOTES: 1. If it is desired to remotely reset both chilled water setpoint and current limit setpoint, 2 ea. are required. If it is desired to remotely reset only one of these setpoints, 1 ea. are required. 2. Replacement Micro Boards are shipped without EPROMs. Remove EPROMs from defective board and use in replacement board. If new EPROM is required, refer to TABLE 1. Micro Board will be supplied after inventory of and -001 is depleted. (No change to operation of unit.) 3. Babcock VF or IEE series transducers supersede series transducers. TABLE 1 EPROMS (also see Fig. 6) Order EPROMS by Part Number. The EPROM VERSION is an Alphanumeric Code that identifies the Application and Revision Level of the EPROM as follows: C S 10 Revision Level (Increments each time EPROM is revised; i.e..08,.09,.10, etc.) S = Standard F = Standard with FAX-4500 Communications T = Standard with Guardian Service/Remote Chiller Communications 0 = Retrofit 1-9 = Production Code 0 = Production 1-9 = Retrofit Code C = Centrifugal Chiller PART NO. VERSION APPLICATION C.01F.11 R11/R123 YT CodePak with FAX-4500 Communications (Supersedes ) C.01T.11 R11/R123 YT CodePak with Guardian Service / Remote Chiller Communications C.10F.11 R11/R123 Monoshell Series E Compressor with FAX-4500 Communications (Supersedes ) C.20F.11 R11/R123 Monoshell Series B & C Compr. with FAX-4500 Communications (Supersedes ) C.30F.11 R11/R123 Monoshell Series 64 Compressor with FAX-4500 (Supersedes ) C.01S.10 Superseded by C.10S.10 Superseded by C.20S.10 Superseded by C.30S.10 Superseded by C.10T.11 R11/R123 Monoshell Series E Compressor with Remote Chiller Communication C.01S Superseded by C.10S Superseded by C.20S Superseded by C.30S Superseded by

4 (Not Shown) 25 (Optional) 26 (Location of Optional Card File) , 5 4, A FIG. 1 ISN CODEPAK CONTROL CENTER DOOR AND HINGED PANEL OPEN A FIG. 2 ISN CODEPAK CONTROL CENTER EXTERIOR 4

5 FORM RP Hinged Panel 15 (TM II Interface Board) 24616A 17 (Cable Fiber-Optic Temperature Connected Here Not Shown) 16 (Cable Fiber-Optic Current Connected Here Not Shown) FIG. 3 ISN CODEPAK CONTROL CENTER DOOR OPEN TURBO-MODULATOR II APPLICATIONS A FIG. 4 ISN CODEPAK CONTROL CENTER DOOR OPEN ELECTRO-MECHANICAL STARTER 5

6 MODEL - 7L 22 MODEL - 14L 23 MODEL - 26L 24 MODEL - 33L 24670A FIG. 5 ISN CODEPAK CONTROL CENTER DOOR OPEN SOLID STATE STARTER APPLICATIONS NOTES for FIG. 6: Beginning on/ about April 1997, Chinese language displays will be supplied with either: two Simplified translation EPROMs or two Traditional translation EPROMs. If Simplified translation is desired, both of the Simplified EPROMs below are required. If Traditional translation is desired, both of the Traditional EPROMs below are required. The EPROM part numbers and on-board socket locations are as follows: EPROM TRANSLATION SOCKET LOCATION Simplified U Simplified U Traditional U Traditional U14 Chinese Language displays contained one EPROM ( ) (socket location U13) that translated to Simplified Chinese and one EPROM ( ) (socket location U14) that translated to Traditional Chinese. The desired translation was then selected by Program Jumper PT0, located on the Chinese language display board. Due to the addition of messages, two EPROMs are now required for each translation as described above. When equipped with these new EPROMs, Program Jumper PT0 can no longer be used to select between Simplified or Traditional translation. If one of these earlier version EPROMs listed in Fig. 6 fail, it must be replaced with two EPROMs as follows: IF THIS EPROM FAILS: REPLACE WITH: PART NO. LOCATION TRANSLATION PART NO. LOCATION U13 Simplified U13 AND U U14 Traditional U13 AND U14 6

7 FORM RP A (Not Shown) 28499A ITEM DESCRIPTION PART NO. 1 PC Board, Chinese Language Display Display, Chinese Language LCD Graphic Transformer, Chinese Language Display 115VAC / 24VAC Cable, Ribbon Micro Board to Chinese Language Display Cable, Ribbon Chinese Display Board to Vacuum Fluorescent Display Cable, Ribbon Chinese Display Board to Chinese Language LCD Display EPROM CC.01F.00 (IC-U13) R11/R123 YT CodePak Simplified Chinese Language * 8 EPROM CC.01F.00 (IC-U14) R11/R123 YT CodePak Traditional Chinese Language * *See Notes on page 6. FIG. 6 CHINESE LANGUAGE DISPLAY COMPONENTS 7

8 Proud Sponsor of the 1998 U.S. Olympic Team 36USC380 P.O. Box 1592, York, Pennsylvania USA Copyright by York International Corporation 1997 Form RP3 (1197) Supersedes: RP3 (993), RP3 (SB1) (594), RP3 (SB2) (195), RP3 (SB3) (895), RP3 (SB4) (696), RP3 (SB5) (996), RP3 (SB6) (797) & RP3 (SB7) (997) Subject to change without notice. Printed in USA ALL RIGHTS RESERVED

OPTIVIEW CONTROL CENTER MODEL YS (STYLE E)

OPTIVIEW CONTROL CENTER MODEL YS (STYLE E) MODEL YS (STYLE E) SCREW LIQUID CHILLERS RENEWAL PARTS Supersedes: 160.80-RP3 (105) Form 160.80-RP3 (307) OPTIVIEW CONTROL CENTER 371-02459-101 371-02579-101 371-02578-101 371-02459-102 371-02579-102 371-02578-102

More information

GRAPHIC CONTROL CENTER , , , , , , 102

GRAPHIC CONTROL CENTER , , , , , , 102 MODEL YR SCREW LIQUID CHILLERS RENEWAL PARTS Supercedes: 160.81-RP3 (307) Form 160.81-RP3 (507) GRAPHIC CONTROL CENTER 371-02772-101, 102 371-02773-101, 102 371-02774-101, 102 371-04175-101, 102 371-04176-101,

More information

MICROCOMPUTER CONTROL CENTER

MICROCOMPUTER CONTROL CENTER OPERATION ROTARY SCREW LIQUID CHILLERS Supersedes: See Back Cover Form 160.47-O1.1 (197) MICROCOMPUTER CONTROL CENTER PART NO. 371-01112-001 or 371-01200-003 FOR MODEL YS BA BA S0 THRU YS FC FB S5 (STYLE

More information

ELECTRICAL CONNECTORS ALL PRODUCTS

ELECTRICAL CONNECTORS ALL PRODUCTS ELECTRICAL CONNECTORS ALL PRODUCTS RENEWAL PARTS Supersedes: NOTHING Form 50.20-RP1 (103) LD08685 TABLE OF CONTENTS PAGE Single Line Micropanel...3 Optiview Panels...4 VSD's and Solid State Starters...5

More information

MODELS: STEAM FIRED YPC-ST-14SC & YPC-ST-16SL Thru YPC-ST-19S

MODELS: STEAM FIRED YPC-ST-14SC & YPC-ST-16SL Thru YPC-ST-19S Supersedes: 155.19-W1 (407) Form: 155.19-W1 (812) TWO-STAGE ABSORPTION CHILLERS WIRING DIAGRAMS CONTRACTOR ORDER NO. JCI CONTRACT NO. JCI ORDER NO. PURCHASER JOB NAME LOCATION ENGINEER REFERENCE DATE APPROVAL

More information

MODELS VSD 270, 292, 351, 385, 419, 424, 503, 608, 658, AND 704 MODELS LVD 270, 292, 351, 385, 419, 424, 503, 608, 658, 704, AND 900

MODELS VSD 270, 292, 351, 385, 419, 424, 503, 608, 658, AND 704 MODELS LVD 270, 292, 351, 385, 419, 424, 503, 608, 658, 704, AND 900 LIQUID COOLED OPTISPEED COMPRESSOR SPEED DRIVE OPERATION MANUAL Supersedes: 160.00-O4 (415) Form 160.00-O4 (1217) MODELS VSD 270, 292, 351, 385, 419, 424, 503, 608, 658, AND 704 MODELS LVD 270, 292, 351,

More information

YK CENTRIFUGAL LIQUID CHILLER

YK CENTRIFUGAL LIQUID CHILLER YK CENTRIFUGAL LIQUID CHILLER OptiView Control Panel OPERATION INSTRUCTION Effective from 11/00 GB i 160-54-OI-GB0 Contents 1 HOME SCREEN 4 2 SYSTEM SCREEN 5 3 EVAPORATOR SCREEN 6 4 CONDENSER SCREEN 8

More information

TROUBLESHOOTING GUIDE FOR LIQUID COOLED VARIABLE SPEED DRIVE

TROUBLESHOOTING GUIDE FOR LIQUID COOLED VARIABLE SPEED DRIVE LIQUID COOLED VARIABLE SPEED DRIVE FOR YCAV (LATITUDE) CHILLERS SERVICE INSTRUCTIONS Supersedes: 201.21-M1 (305) Form 201.21-M1 (307) TROUBLESHOOTING GUIDE FOR LIQUID COOLED VARIABLE SPEED DRIVE 50056

More information

32MP Gateway. Overview and Configuration Manual

32MP Gateway. Overview and Configuration Manual 32MP Gateway Overview and Configuration Manual 32MP Gateway Overview and Configuration Manual This document is the property of Carrier Corporation and is delivered on the express condition that it is not

More information

BACnet MS/TP Interface User s Guide

BACnet MS/TP Interface User s Guide PoolPak MPK with CommandPak Control System CPCS BACnet MS/TP Interface User s Guide DOCUMENT #: SVW07-BACNET-MSTP-20171020 UPDATED: OCTOBER 2017 INTRODUCTION PoolPak dehumidifiers equipped with an CommandPak

More information

ES Service Information

ES Service Information ES Service Information File In/With: 160.54-M1, 160.54-O1 160.55-M1, 160.55-O1 Equipment Affected: OptiView Panel Software Enhancement - OptiSave VSD Software Feature SI0068 New 1-04 YK & YT Chillers with

More information

PoolPak MPK with CommandPak Control System CPCS BACnet /IP User s Guide DOCUMENT #: SVW07-MPKBACNIP

PoolPak MPK with CommandPak Control System CPCS BACnet /IP User s Guide DOCUMENT #: SVW07-MPKBACNIP PoolPak MPK with CommandPak Control System CPCS BACnet /IP User s Guide DOCUMENT #: SVW07-MPKBACNIP-20171020 UPDATED: OCTOBER 2017 INTRODUCTION PoolPak dehumidifiers equipped with an CommandPak Control

More information

19XR CONTROLS UPGRADE with Optional VFD control

19XR CONTROLS UPGRADE with Optional VFD control MCS Total Solutions for all your HVAC/R Control Needs 19XR CONTROLS UPGRADE with Optional VFD control This brochure describes a standard upgrade package for the 19XR CHILLER. Each Control upgrade installation

More information

FX2-CHILLER. Digital Control. Operations Manual

FX2-CHILLER. Digital Control. Operations Manual FX2-CHILLER Digital Control Operations Manual Micro Air Corporation Phone (609) 259-2636 124 Route 526 www.microair.net Allentown NJ 08501 Fax (609) 259-6601 Introduction: The FX2-CHILLER digital control

More information

Wiring Diagrams UNITS WITH STARTING SERIAL NUMBER 3507Q

Wiring Diagrams UNITS WITH STARTING SERIAL NUMBER 3507Q AQUASNAP 30RB060-390 Air-Cooled Liquid Chillers with COMFORTLINK Controls 60 Hz Wiring Diagrams UNITS WITH STARTING SERIAL NUMBER 3507Q INDEX* POWER SCHEMATICS 30RB Unit Size Voltage Figure Number Label

More information

Wiring Diagrams DIAGRAM INDEX. POWER SCHEMATICS Unit 30GXN,R Voltage Figure Number

Wiring Diagrams DIAGRAM INDEX. POWER SCHEMATICS Unit 30GXN,R Voltage Figure Number 30GXN,R Sizes 080-528 Air-Cooled Chillers with ComfortLink Controls 50/60 Hz Wiring Diagrams DIAGRAM INDEX POWER SCHEMATICS Unit 30GXN,R Voltage Figure Number Label Diagram No. 30GX 080-178* ALL 1 505429

More information

Metasys Integrator Multistack Application

Metasys Integrator Multistack Application Metasys Connectivity Technical Manual 629.5 Metasys Integrator Section Application Note Issue Date 0998 APPLICATION NOTE Metasys Integrator Multistack Application lntroduction Page *3 Application Details

More information

CTC Low Temperature Process Chillers

CTC Low Temperature Process Chillers INNOVATE DESIGN APPLY CTC Low Temperature Process Chillers 5-500 Tons OUR BUSINESS IS COOLING YOURS TM When commercial grade isn t enough When it comes to process cooling, every application is unique in

More information

INTEGRATED SYSTEMS AND CONTROL, INC. User s Hardware Manual. PCMNET V 7. xx

INTEGRATED SYSTEMS AND CONTROL, INC. User s Hardware Manual. PCMNET V 7. xx INTEGRATED SYSTEMS AND CONTROL, INC. User s Hardware Manual PCMNET V 7. xx INTEGRATED SYSTEMS AND CONTROLS, INC. PCMNET Users Manual Revised 2/4/2005 2003-2005 Integrated Systems and Control. Inc. PO Box

More information

FX-2 Control Board ASY-360-XXX Setup and Configuration Guide

FX-2 Control Board ASY-360-XXX Setup and Configuration Guide FX-2 Control Board ASY-360-XXX Setup and Configuration Guide Micro Air Corporation Phone (609) 259-2636 124 Route 526. WWW.Microair.net Allentown NJ 08501 Fax (609) 259-6601 Table of Contents Introduction...

More information

CDN503 HIGH DENSITY I/O ADAPTER USER GUIDE

CDN503 HIGH DENSITY I/O ADAPTER USER GUIDE CDN503 HIGH DENSITY I/O ADAPTER USER GUIDE 13050301 (c) Copyright DIP Inc., 1996 DIP Inc. P.O. Box 9550 MORENO VALLEY, CA 92303 714-924-1730 CONTENTS DN503 PRODUCT OVERVIEW 1 DN503 INSTALLATION 1 POWER

More information

FX-2 Control Board ASY-360-XXX Setup and Configuration Guide

FX-2 Control Board ASY-360-XXX Setup and Configuration Guide FX-2 Control Board ASY-360-XXX Setup and Configuration Guide Micro Air Corporation Phone (609) 259-2636 124 Route 526. WWW.Microair.net Allentown NJ 08501 Fax (609) 259-6601 Table of Contents Introduction...

More information

FrigoPack FU+ New Generation of Intelligent Refrigeration Inverters

FrigoPack FU+ New Generation of Intelligent Refrigeration Inverters FU+ New Generation of Intelligent Refrigeration Inverters Efficient and Energy-saving Control of Refrigeration Compressors and Condenser Fans www.frigokimo.com Effective speed control saves energy and

More information

New Microprocessor Control Technology

New Microprocessor Control Technology New Microprocessor Control Technology Easy to Operate and Easy to View The GForce microprocessor control panel display is clear, crisp, and easy to view. Utilizing a large 15 diagonal, full 32-bit-color,

More information

Supplement to PM WSC/WDC-1 MicroTech II for Centrifugal Compressor Water Chillers

Supplement to PM WSC/WDC-1 MicroTech II for Centrifugal Compressor Water Chillers Engineering Data SED: 8012 Group: Centrifugal Chiller Date: March 2002 Supercedes: New Supplement to PM WSC/WDC-1 MicroTech II for Centrifugal Compressor Water Chillers Model WSC/WDC 2002 McQuay International

More information

PEH-WSC CONTROLS UPGRADE with Optional VFD control

PEH-WSC CONTROLS UPGRADE with Optional VFD control MCS Total Solutions for all your HVAC/R Control Needs PEH-WSC CONTROLS UPGRADE with Optional VFD control This brochure describes a standard upgrade package for the PEH-WSC Chillers. Each Control upgrade

More information

D/E Remote Relay Panel User Guide

D/E Remote Relay Panel User Guide D/E Remote Relay Panel User Guide This manual should remain with the unit. D/E Remote Relay Panel Detailed Specifications...2 Environmental Specs...2 Power Supply Requirements...2 Relay Outputs (8)...2

More information

RTAA CONTROLS UPGRADE

RTAA CONTROLS UPGRADE MCS Total Solutions for all your HVAC/R Control Needs RTAA CONTROLS UPGRADE This brochure describes a standard upgrade package for the RTAA Chiller. Each Control upgrade installation is unique. It may

More information

Service Information. File In/With: N/A. Equipment Affected: YCAV & YCIV Chillers

Service Information. File In/With: N/A. Equipment Affected: YCAV & YCIV Chillers Service Information File In/With: N/A (Supersedes SI0144 [11-06]) Equipment Affected: YCAV & YCIV Chillers SI0144 Rev 2 9-08 Ordering, Installation & Activation of YCAV & YCIV Optimized IPLV Aftermarket

More information

ADDENDUM WCFX. Vision 2020i Touch Screen Controller. - a1 - Vision 2020i Controller

ADDENDUM WCFX. Vision 2020i Touch Screen Controller. - a1 - Vision 2020i Controller WCFX Vision 2020i Touch Screen Controller - a1 - 1.4 VISION 2020i CONTROLLER AND TERMINAL 1.4.1.1 The fourteen touch keys: Key Description MAIN Display the main screen Vision 2020i controller is equipped

More information

CDN502 HIGH DENSITY I/O ADAPTER USER GUIDE

CDN502 HIGH DENSITY I/O ADAPTER USER GUIDE CDN502 HIGH DENSITY I/O ADAPTER USER GUIDE 13050201 (c) Copyright DIP Inc., 1996 DIP Inc. P.O. Box 9550 MORENO VALLEY, CA 92303 714-924-1730 CONTENTS DN502 PRODUCT OVERVIEW 1 DN502 INSTALLATION 1 POWER

More information

MPC Air-Cooled Chillers MPC-FC Free-Cooling Chillers

MPC Air-Cooled Chillers MPC-FC Free-Cooling Chillers INNOVATE DESIGN APPLY www.motivaircorp.com MPC Air-Cooled Chillers MPC-FC Free-Cooling Chillers ½ - 100 Tons OUR BUSINESS IS COOLING YOURS. When commercial grade isn t enough Motivair is a world-class

More information

FRICK QUANTUM COMPRESSOR CONTROL PANEL VERSION 4.5x

FRICK QUANTUM COMPRESSOR CONTROL PANEL VERSION 4.5x S90-010 M/JUL 2002 File: SERVICE MANUAL - SECTION 90 Replaces: S90-010 M/JUL 01 Dist: 3, 3a, 3b, 3c FRICK QUANTUM COMPRESSOR CONTROL PANEL VERSION 4.5x S90-010 M FRICK QUANTUM COMPRESSOR CONTROL PANEL

More information

SSW06. Soft Starters.

SSW06. Soft Starters. The is WEG s third generation Soft Starter line. The keypad, with dual display, has red LED digits which provide visibility and make programming easier. Integral bypass contacts eliminate heat dissipation

More information

Automatic Capacitor Controls

Automatic Capacitor Controls 1 Automatic Capacitor Controls Innovative Reliable Versatile Simple Control For All Seasons The MCAP II and ecap II series of capacitor controls are a powerful yet affordable choice for controlling single

More information

Viconics VT76x6W Water-source Heat Pump Controllers Engineering Guide Specification

Viconics VT76x6W Water-source Heat Pump Controllers Engineering Guide Specification Viconics VT76x6W Water-source Heat Pump Controllers Engineering Guide Specification General The VT76xxW series is designed for single-stage and multi-stage control of water source heat pumps with dedicated

More information

REFRIGERATION AND AIR CONDITIONING. On Site Guide AK2-SC 255

REFRIGERATION AND AIR CONDITIONING. On Site Guide AK2-SC 255 REFRIGERATION AND AIR CONDITIONING On Site Guide AK2-SC 255 How to Use This Guide Read this Guide completely as you install and start up your new AK2-SC 255 controller. The guide will give you thorough

More information

FRICK QUANTUM COMPRESSOR CONTROL PANEL VERSION 5.0x

FRICK QUANTUM COMPRESSOR CONTROL PANEL VERSION 5.0x S90-010 M/APR 2004 File: SERVICE MANUAL - SECTION 90 Replaces: S90-010 M/APR 02 Dist: 3, 3a, 3b, 3c FRICK QUANTUM COMPRESSOR CONTROL PANEL VERSION 5.0x S90-010 M FRICK QUANTUM COMPRESSOR CONTROL PANEL

More information

Trailer & Rail Refrigeration Units

Trailer & Rail Refrigeration Units EASY TO RUN X4 7300/7500 Trailer & Rail Refrigeration Units Display Display Screens Starting Unit IntelliSet Pretrip Changing Setpoint Start-Stop or Continuous Operation Data Recorder/Trip Start Manual

More information

Lab and Central Plant Controller

Lab and Central Plant Controller Metasys Network Sales Resource Manual 635 Application Specific Controllers Section Product Bulletin Issue Date 0290 Lab and Central Plant Controller The Metasys Lab and Central Plant (LCP) Controller is

More information

CT-8000 S3. digital circuit breaker analyzer

CT-8000 S3. digital circuit breaker analyzer CT-8000 S3 digital circuit breaker analyzer CT-8000 S3 digital circuit breaker analyzer Product Overview The CT-8000 S3 is Vanguard's fourth generation EHV circuit breaker analyzer. The CT-8000 S3 is available

More information

Optimizing Chilled Water Plant Performance. David Herman, PE, LEED AP Principal EnerG Associates, LLC

Optimizing Chilled Water Plant Performance. David Herman, PE, LEED AP Principal EnerG Associates, LLC Optimizing Chilled Water Plant Performance David Herman, PE, LEED AP Principal EnerG Associates, LLC Optimizing Chilled Water Plant Learning Objectives Performance Review the design and operating characteristics

More information

SERVICE MANUAL OR (AB SERIAL NUMBERS) April Revision B. Rupprecht & Patashnick Co., Inc. R&P Part Number

SERVICE MANUAL OR (AB SERIAL NUMBERS) April Revision B. Rupprecht & Patashnick Co., Inc.  R&P Part Number SERVICE MANUAL TEOM SERIES 1400a AMBIENT PARTICULA ARTICULATE TE (PM-10) MONITOR OR (AB SERIAL NUMBERS) April 2004 Revision B R&P Part Number 42-003348 Rupprecht & Patashnick Co., Inc. www.rpco.com the

More information

Andover ContinuumTM. b3850 Series Terminal Controllers

Andover ContinuumTM. b3850 Series Terminal Controllers TM b3850 Series Terminal Controllers The TM b3850 series controllers are native BACnet controllers that communicate on an RS-485 field bus as Master devices using the MS/TP BACnet protocol. 02 Features

More information

Daikin McQuay. Centrifugal Chiller LiquiFlo 2.0 Water-Cooled VFD VF2037, VF2055, VF2080, VF2110

Daikin McQuay. Centrifugal Chiller LiquiFlo 2.0 Water-Cooled VFD VF2037, VF2055, VF2080, VF2110 Replacement Parts List No. 70002300 Revision B 08/204 Daikin McQuay Centrifugal Chiller LiquiFlo 2.0 Water-Cooled VFD VF2037, VF2055, VF2080, VF20 To find your Daikin Applied parts distributor, call -800-377-2787

More information

Trailblazer AGZ-E air-cooled scroll chillers

Trailblazer AGZ-E air-cooled scroll chillers Trailblazer AGZ-E air-cooled scroll chillers 30 to 240 tons with Variable Speed Condenser Fan Technology The right features, the right value, right now Intelligent Equipment AGZ-E 30 to 161 RapidRestore

More information

Allen-Bradley PLCs. 100 Programmable Controller Processor Unit -Catalog Nos LPI01, -LP102, -LP103, -LP104 SLC TM. The Unit

Allen-Bradley PLCs. 100 Programmable Controller Processor Unit -Catalog Nos LPI01, -LP102, -LP103, -LP104 SLC TM. The Unit PRODUCT DATA SLC TM 100 Programmable Controller Processor Unit -Catalog Nos. 1745-LPI01, -LP102, -LP103, -LP104 The SLC 100 programmab/e Contro"er The SLC 100 Programmable Controller is easy to program,

More information

VMS Co., Ltd. VMS Reliability Systems - Korea

VMS Co., Ltd. VMS Reliability Systems - Korea VMS Co., Ltd VMS Reliability Systems - Korea Room 1106, QB Centum Bldg, 90, Centum Jungang-ro, Haeundae-gu, Busan, Korea TEL +82 51 782 2323 FAX +82 51 782 0808 E-MAIIL admin@vmsco.co.kr www.vmsco.co.kr

More information

Electronics. Plate 1.1 MPD -1 Computer Display Module Three-Grade, Four-Grade, and Fixed Blender F F

Electronics. Plate 1.1 MPD -1 Computer Display Module Three-Grade, Four-Grade, and Fixed Blender F F Plate. MPD - Computer Display Module Three-Grade, Four-Grade, and Fixed Blender 3 5 2 2 3 F 5 6 F2 7 8 9 0 7 6 8 9 7 0 5 3 6 2 8 Page 0 PT-80 MPD Series Illustrated Parts Manual /93 Housing, Black T6037-G2S6

More information

COND. A ENABLE RELAY CONTACT COOLA ENABLE 24 VAC. RATING IS 1 AMP COND. B ENABLE COOL B ENABLE.

COND. A ENABLE RELAY CONTACT COOLA ENABLE 24 VAC.   RATING IS 1 AMP COND. B ENABLE COOL B ENABLE. Factory Packaged Controls Coil Products Two Head Pressure Module Orion No.:OE370-23-HP2C 1 2 3 4 www.aaon.com www.orioncontrols.com Circuit A1 TRANSDUCER #1 Circuit A2 TRANSDUCER #2 Circuit B1 TRANSDUCER

More information

OPERATION INSTRUCTIONS

OPERATION INSTRUCTIONS 2018 Lennox Industries Inc. Dallas, Texas, USA OPERATION INSTRUCTIONS V0STAT52 Wireless Indoor Unit Controller CONTROLS 507459-04 05/2018 This manual must be left with the owner for future reference. IMPORTANT

More information

Next Generation DCP Optimization using MV VSDs

Next Generation DCP Optimization using MV VSDs Next Generation DCP Optimization using MV VSDs Vivek Apte Regional Product Director Johnson Controls - Middle East Cell : +971506243059 IDEA 2016- Dubai 1 Central Plant Optimization Energy and operating

More information

TECHNICAL MANUAL WATER 300 C 5300 CV/06-00 GB

TECHNICAL MANUAL WATER 300 C 5300 CV/06-00 GB T E C H N I C A L M A N U A L TECHNICAL MANUAL C 5300 CV/06-00 GB GB The information contained in this document may be modified without prior notice and is in no way binding, even implicitly, for CLIMAVENETA.

More information

AUTOMATIC AND AUTONOMOUS REMOTE WATER LEVEL AND WATER QUALITY MONITORING STATION

AUTOMATIC AND AUTONOMOUS REMOTE WATER LEVEL AND WATER QUALITY MONITORING STATION Brochure nº 9722.0048 AUTOMATIC AND AUTONOMOUS REMOTE WATER LEVEL AND WATER QUALITY MONITORING STATION MODEL HYDRODATA-2000C SERIES GEONICA, S.A. - Alejandro Rodríguez, nº 22-28039 Madrid - Spain Tel.

More information

SSW06. Soft Starters. Applications. Standard Features. Pumps Fans Blowers Compressors Crushers Saws Grinders Mixers.

SSW06. Soft Starters. Applications. Standard Features. Pumps Fans Blowers Compressors Crushers Saws Grinders Mixers. General Information CFW10 CFW100 CFW08 CFW500 CFW700 CFW701 CFW11 EDP11 CFW11M SSW05 SSW07 GPH2 TPH2 The is WEG s third generation Soft Starter line. The keypad, with dual display, has red LED digits which

More information

AccuTank ULTRASONIC LEVEL MONITORING SYSTEM

AccuTank ULTRASONIC LEVEL MONITORING SYSTEM AccuTank ULTRASONIC LEVEL MONITORING SYSTEM FLO-CORP s AccuTank Ultrasonic Level Monitoring System is the most economical, reliable and accurate remote monitoring system on the market. This affordable

More information

ISO 9001 CERTIFIED. 607 NW 27th Ave Ocala, FL Phone: (352) or Fax: (352) OPERATION MANUAL

ISO 9001 CERTIFIED. 607 NW 27th Ave Ocala, FL Phone: (352) or Fax: (352) OPERATION MANUAL ISO 9001 CERTIFIED Phone: (352) 629-5020 or 800-533-3569 Fax: (352)-629-2902 ES-Key 18 Input module (selectable polarity) with 3 outputs (selectable polarity) with 1 analog (selectable 0-5V or 4-20mA)

More information

FX06 Field Controller

FX06 Field Controller Code No. LIT-1900406 Issued October 19, 2012 Facility Explorer FX06 Field Controller The FX06 is a high performance field controller designed specifically for commercial Heating, Ventilating, Air Conditioning,

More information

OPERATING INSTRUCTIONS AND SERVICE MANUAL OUTDOOR HOCKEY SCOREBOARD MODEL MP-3555 WITH MP-3000 CONTROL MODEL

OPERATING INSTRUCTIONS AND SERVICE MANUAL OUTDOOR HOCKEY SCOREBOARD MODEL MP-3555 WITH MP-3000 CONTROL MODEL OPERATING INSTRUCTIONS AND SERVICE MANUAL OUTDOOR HOCKEY SCOREBOARD MODEL MP-3555 WITH MP-3000 CONTROL MODEL EFFECTIVE S.N.XXXX, DEC 20, 1999 1. General Information TABLE OF CONTENTS 1.1 Description 1.2

More information

FRICK QUANTUM LX COMPRESSOR CONTROL PANEL

FRICK QUANTUM LX COMPRESSOR CONTROL PANEL Form S90-022 M (JULY 2008) - SERVICE File: SERVICE MANUAL - SECTION 90 Replaces: S90-020 M/MAY 2007 Dist: 3, 3a, 3b, 3c QUANTUM LX COMPRESSOR CONTROL PANEL VERSION 6.5x Page 2 TABLE OF CONTENTS QUANTUM

More information

FX05 Controller. FX05 Controller. Features and Benefits Compatible with standard BAS protocols. LON and N2Open plug-in comm.

FX05 Controller. FX05 Controller. Features and Benefits Compatible with standard BAS protocols. LON and N2Open plug-in comm. Platform Catalogue Section 1 Product Bulletin FX05 Issue Date 08 2002 FX05 Controller The FX05 is a high performance controller specifically designed for single compressor chillers and heat pumps. It includes

More information

Motivair MLC-SC Air-Cooled Scroll Chillers Tons

Motivair MLC-SC Air-Cooled Scroll Chillers Tons INNOVATE DESIGN APPLY www.motivaircorp.com Motivair MLC-SC Air-Cooled Scroll Chillers 100 285 Tons OUR BUSINESS IS COOLING YOURS. When commercial grade isn t enough Businesses who function in today s advanced

More information

UC-2000 Installation Manual Unicorn Computers Technology Limited

UC-2000 Installation Manual Unicorn Computers Technology Limited UC2000 Installation Manual Copyright 2003. All rights reserved. Table of Contents Specifications 2 Enclosure for the UC2000 Controller 3 Unicorn Access Control System Configuration 4 UC2000 Controller

More information

Andover ContinuumTM Infinet II

Andover ContinuumTM Infinet II Andover ContinuumTM Infinet II i2850 Series The i2850, i2851, and i2853 controllers provide cost-effective DDC control of individual terminal units (e.g. VAV boxes, fan-powered induction units, unit ventilators,

More information

Product Catalog. senseware.co Tysons Boulevard Floor 5 Tysons VA, 22102

Product Catalog. senseware.co Tysons Boulevard Floor 5 Tysons VA, 22102 Product Catalog 2018 senseware.co 571.766.6443 1775 Tysons Boulevard Floor 5 Tysons VA, 22102 TABLE OF CONTENTS Senseware Base Hardware..................................... 2 Environmental Sensors......................................

More information

Digivac Model 22W tm and 22wLcd tm Wide Range Linearized Vacuum Controller/Transmitter/232

Digivac Model 22W tm and 22wLcd tm Wide Range Linearized Vacuum Controller/Transmitter/232 Digivac Model 22W tm and 22wLcd tm Wide Range Linearized Vacuum Controller/Transmitter/232 Thank you for purchasing the Digivac Model 22W (LCD) Vacuum Transmitter. This instrument works in conjunction

More information

FRICK QUANTUM CONDENSER/VESSEL CONTROL PANEL VERSION 2.1x

FRICK QUANTUM CONDENSER/VESSEL CONTROL PANEL VERSION 2.1x S90-555 M/OCT 2001 File: SERVICE MANUAL - SECTION 90 Replaces: NOTHING (New Manual) Dist: 3, 3a, 3b, 3c FRICK QUANTUM CONDENSER/VESSEL CONTROL PANEL VERSION 2.1x S90-555 M Page 2 FRICK QUANTUM CONDENSER/VESSEL

More information

GUIDE TO SP STARTER SHIELD (V3.0)

GUIDE TO SP STARTER SHIELD (V3.0) OVERVIEW: The SP Starter shield provides a complete learning platform for beginners and newbies. The board is equipped with loads of sensors and components like relays, user button, LED, IR Remote and

More information

SED2 VFD NEMA Type 3R Bypass/Air Conditioner

SED2 VFD NEMA Type 3R Bypass/Air Conditioner SED2 VFD NEMA Type 3R Bypass/Air Conditioner Description The NEMA Type 3R Bypass with Air Conditioner allows SED2 to be employed in a harsh environment. The SED2 is designed specifically for HVAC applications

More information

MicroTech III Water Source Heat Pump BACnet MS/TP Communication Module

MicroTech III Water Source Heat Pump BACnet MS/TP Communication Module Installation and Maintenance Manual IM 928- Group: Controls Part Number: 66920770 Date: July 2009 Supersedes: IM 928 MicroTech III Water Source Heat Pump BACnet MS/TP Communication Module NOTICE Use this

More information

GRASSO SYSTEM CONTROL

GRASSO SYSTEM CONTROL Control device for Packages and Chillers with screw compressors Product information 09.2002/ 2 638630_pi gsc gbr.doc Copyright GmbH Refrigeration Technology The contents of this documentation and the enclosed

More information

Tri-Phase. true 3-phase transformer turns ratio tester

Tri-Phase. true 3-phase transformer turns ratio tester Tri-Phase true 3-phase transformer turns ratio tester Tri-Phase true 3-phase transformer turns ratio tester Product Overview The Tri-Phase can be used as a stand-alone unit or can be computer-controlled.

More information

ISO 9001 CERTIFIED. 607 NW 27th Ave Ocala, FL Phone: (352) or Fax: (352) OPERATION MANUAL

ISO 9001 CERTIFIED. 607 NW 27th Ave Ocala, FL Phone: (352) or Fax: (352) OPERATION MANUAL ISO 9001 CERTIFIED Phone: (352) 629-5020 or 800-533-3569 Fax: (352)-629-2902 ES-Key 16 Output module (selectable polarity) P/N 610-00031 PAGE 1 of 10 1. REVISION LOG... 1 2. MODULE OVERVIEW... 2 2.1. SCOPE...

More information

RGX COMMUNICATIONS GATEWAY

RGX COMMUNICATIONS GATEWAY RGX COMMUNICATIONS GATEWAY BTU Ventilation Corporation 47418 US Highway 10 Perham, Mn 56573 USA Phone (218) 346-7482 Fax (218) 346-7485 http:/// Manual ver 2.1 Copyright BTU Ventilation Corp 2008 RGX Communications

More information

Application Engineering

Application Engineering Application Engineering Application Engineering Commercial Comfort Controller (543-0175-00) Installation Guide May 2012 Contents Mounting... 1 Connections and Wiring... 1 Wiring Considerations... 1 Input

More information

TRF-250A. automatic, 3-phase transformer turns ratio finder

TRF-250A. automatic, 3-phase transformer turns ratio finder TRF-250A automatic, 3-phase transformer turns ratio finder TRF-250A 3-phase transformer turns ratio finder Product Overview The TRF-250A is the battery-powered version of the TRF- 250. Its battery offers

More information

SP6R Level Controller Operation Manual

SP6R Level Controller Operation Manual SP6R Level Controller Operation Manual www.sjerhombus.com SP6R LEVEL CONTROLLER INTRODUCTION SJE-Rhombus, an industry leader in water and wastewater pump controls, introduces the SP6R Level Controller.

More information

E510. Compact Drive IP 20/ NEMA HP (230V) 1-75 HP (460V)

E510. Compact Drive IP 20/ NEMA HP (230V) 1-75 HP (460V) E510 Compact Drive IP 20/ NEMA 1 0.5-40 HP (230V) 1-75 HP (460V) Control Mode Application & Selection Guide The E510 compact AC Drive is an easily configurable product that controls many motor driven applications.

More information

FRICK QUANTUM ACUair CONTROL PANEL VERSION 2.1x

FRICK QUANTUM ACUair CONTROL PANEL VERSION 2.1x S90-500 M/JULY 2002 File: SERVICE MANUAL - SECTION 90 Replaces: NOTHING (New Information) Dist: 3, 3a, 3b, 3c FRICK QUANTUM ACUair CONTROL PANEL VERSION 2.1x S90-500 M FRICK QUANTUM ACUair CONTROL PANEL

More information

UPGRADE PROGRAM. V70 Series Pumps vs V81T Series Pumps

UPGRADE PROGRAM. V70 Series Pumps vs V81T Series Pumps VARIAN vacuum technologies UPGRADE PROGRAM V70 Series Pumps vs V81T Series Pumps Technical Memo Technical Memo - 1 - V70 series vs V81-T INDEX Outline drawings ISO63 3 Outline drawings CF2-¾ 4 Outline

More information

COMFORT CONTROL CENTER SERVICE INSTRUCTIONS

COMFORT CONTROL CENTER SERVICE INSTRUCTIONS USA SERVICE OFFICE Dometic Corporation 2320 Industrial Parkway Elkhart, IN 46516 574-294-2511 CANADA Dometic Corporation 46 Zatonski, Unit 3 Brantford, ON N3T 5L8 CANADA 519-720-9578 For Service Center

More information

5B Series 16 Channel Backplane 5B01 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

5B Series 16 Channel Backplane 5B01 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM 5B Series 16 Channel Backplane 5B01 FEATURES Mix and Match 5B Series I/O Module Capability Factory Mutual (FM) Approved Approved for Use in Class I, Division2, Groups A, B, C, and D Locations. CE Certified:

More information

BB5-Lite TECHNICAL MANUAL

BB5-Lite TECHNICAL MANUAL BB5-Lite TECHNICAL MANUAL Product Support 1800 354 434 CC - BB5 - LITE LITE with Plug & Play technology www.blackbox.net.au Designed by IAS in Brisbane Made in Australia Product Support 1800 354 434 www.ias.net.au

More information

Andover ContinuumTM Infinet II

Andover ContinuumTM Infinet II Andover ContinuumTM Infinet II i2920 System Controllers The Andover Continuum Infinet II i2920 System Controller is designed to meet the needs of your most demanding control and monitoring applications

More information

Refrigeration Notes ECI upgrade process

Refrigeration Notes ECI upgrade process Refrigeration Notes ECI upgrade process Information X Sales Info X Product Info X Application info OEM Info Target X Commercial X Technical Subject X Commercial refrigeration Industrial refrigeration X

More information

Specification and Design Catalog. Waterside Economizer

Specification and Design Catalog. Waterside Economizer Specification and Design Catalog Waterside Economizer Table of Contents Waterside Economizer Applications.................................................... 4 Application Notes..................................................................

More information

Sales and Engineering Data Sheet ED

Sales and Engineering Data Sheet ED Sales and Engineering Data Sheet ED 15100-4 MicroTech II Chiller Unit Controller Protocol Information BACnet Networks (IP, Ethernet) Group: Controls Part Number: ED 15100 Date: October 2016 WSC Water-Cooled

More information

PLC Fundamentals. Module 1: Introduction to PLC. Academic Services Unit PREPARED BY. August 2011

PLC Fundamentals. Module 1: Introduction to PLC. Academic Services Unit PREPARED BY. August 2011 PLC Fundamentals PREPARED BY Academic Services Unit August 2011 Applied Technology High Schools, 2011 ATE1212 PLC Fundamentals Module Objectives Upon successful completion of this module, students will

More information

TRF-250. automatic, 3-phase transformer turns ratio finder

TRF-250. automatic, 3-phase transformer turns ratio finder TRF-250 automatic, 3-phase transformer turns ratio finder TRF-250 3-phase transformer turns ratio finder Product Overview The 250V Test Voltage Advantage The TRF-250 is Vanguard s fourth generation transformer

More information

Precise temperature control and high reliability

Precise temperature control and high reliability LASER COOLING Precise temperature control and high reliability Heat sinks for actively and passively cooled light sources Thermoelectric recirculating chillers Compressor based recirculating chillers Cabinet

More information

SERIES CMT CARBON MONOXIDE GAS TRANSMITTER

SERIES CMT CARBON MONOXIDE GAS TRANSMITTER SERIES CMT CARBON MONOXIDE GAS TRANSMITTER INSTALLATION OPERATION AND MAINTENANCE MANUAL DWYER INTRUMENTS, INC. PO BOX 373, MICHIGAN CITY, IN. 46360 USA PHONE: 800-872-9141 FAX: 219-872-9057 Web: www.dwyer-inst.com

More information

CENTRIFUGAL CONTROLS UPGRADE with Optional VFD control. MCS Total Solutions for all your HVAC\R Control Needs

CENTRIFUGAL CONTROLS UPGRADE with Optional VFD control. MCS Total Solutions for all your HVAC\R Control Needs MCS Total Solutions for all your HVAC\R Control Needs CENTRIFUGAL CONTROLS UPGRADE with Optional VFD control This brochure describes a standard upgrade package for a Centrifugal Chiller. Each Control upgrade

More information

Section 4 - Automation Assembly

Section 4 - Automation Assembly Table of Contents 1. Process Control Unit (PCU) 1.1 Introduction 1.2 PCU Power Cable 1.3 Display and input controls 1.4 Analog Inputs 1.5 FET Outputs 1.6 Thermocouple Connectors 1.7 Table of Thermocouples

More information

Environmental Chamber Programmer/Controller

Environmental Chamber Programmer/Controller Environmental Chamber Programmer/Controller Complete Single, Dual or Three Channel Control System. or - Patented FastTRAC Part Temperature Control. or FastTRAC Control Plus Second Channel for Vibration,

More information

MIAC-01 Now you are in control

MIAC-01 Now you are in control Page 1 Now you are in control General purpose industrial controller Full graphical programming language supplied A wide variety of applications Page 2 Introduction What does it do? MIAC (Matrix Industrial

More information

Rev MultiFlex PAK Compressor/ Condenser Control Board User s Guide

Rev MultiFlex PAK Compressor/ Condenser Control Board User s Guide 026-1712 Rev 2 09-03-04 MultiFlex PAK Compressor/ Condenser Control Board User s Guide 1640 Airport Road, Suite 104 Kennesaw, GA 31044 Phone: (770) 425-2724 Fax: (770) 425-9319 ALL RIGHTS RESERVED. The

More information

Bolt 18F2550 System Hardware Manual

Bolt 18F2550 System Hardware Manual 1 Bolt 18F2550 System Hardware Manual Index : 1. Overview 2. Technical specifications 3. Definition of pins in 18F2550 4. Block diagram 5. FLASH memory Bootloader programmer 6. Digital ports 6.1 Leds and

More information

SmartVFD Frame 8 Wiring Diagrams and Dimensional Drawings

SmartVFD Frame 8 Wiring Diagrams and Dimensional Drawings Smart Frame 8 Wiring Diagrams and Dimensional Drawings Smart Frame Size 8 460 Vac: 00-50 HP 08/0 Vac: 50-75 HP SPECIFICATION DATA CONTENTS Smart Frame 8 Wiring Diagrams... Frame 8, Fused Disconnect Wiring

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS www.altroniccontrols.com INSTALLATION INSTRUCTIONS EXACTA 21 MONITORING AND CONTROL SYSTEM CAUTION: The EXACTA 21 CONTROL SYSTEM is CSA CERTIFIED FOR use in Class I, GROUPS C & D, Division 2 hazardous

More information

Trillium US Inc. E1000 Dual Channel Temperature Monitor / Water Pump Controller User s Manual Rev A / March 2016

Trillium US Inc. E1000 Dual Channel Temperature Monitor / Water Pump Controller User s Manual Rev A / March 2016 97-00041-002 Trillium US Inc. E1000 Dual Channel Temperature Monitor / Water Pump Controller User s Manual Rev A / March 2016 For information about Trillium US Inc., visit the Trillium US Inc. Web site

More information