1 ES Service Information File In/With: M1, O M1, O1 Equipment Affected: OptiView Panel Software Enhancement - OptiSave VSD Software Feature SI0068 New 1-04 YK & YT Chillers with OptiView Control Panels & VSD SI0068 (104) Contents OptiSave General Overview Page 1 OptiSave Installation Instructions Page 2 OptiSave Operation Overview Page 5 OptiSave Data Input, Programmable, Derived Page 11 OptiSave YorkTalk3 Parameters Page 12 OptiSave Trend or Custom Screen Slot Number Page 12 OptiSave Reports Page OptiSave Feature Screens, Manual Supplements YT Home Screen Page 16 YT Operations Screen Page 18 YK Home Screen Page 20 YK Operations Screen Page 23 YT & YK Motor/Variable Speed Drive Screen Page 25 OptiSave Energy Analyzer Screen Page 27 OptiSave Graph Screen Page 29 OptiSave Energy Analyzer Data Screen Page 30 General Overview The OptiSave Energy Analyzer feature calculates the amount of energy that has been saved in applying a variable speed drive versus a constant speed drive on a centrifugal YT or YK chiller. The savings is determined by calculating the energy consumption of a constant speed drive (displayed via CSD kwh Meter), and subtracting the measured energy consumption of the variable speed drive (displayed via VSD kwh Meter). The resulting difference is the energy savings. The OptiSave feature only generates data that is displayed and written to the BRAM, it does not affect chiller operation or performance. The energy consumption of the constant speed drive is calculated by using equations that have been developed to provide an equivalent constant speed operating point based on the Input Power (VSD kw) of the variable speed drive and the Return Chilled Liquid Temperature. The Chiller OptiView Software is shipped with the OptiSave feature disabled. The commissioning service technician may enable the OptiSave feature, if desired, by contacting Service Marketing ( ) to obtain the following necessary installation and setup information: Admin. Password, specific to Software Version Chiller VSD Design kw, specific to chiller Chiller CSD Design kw, specific to chiller References OptiSave Marketing Overview YT OptiView Control Center Operation & Maintenance YT OptiView Control Center Service Instructions YK OptiView Control Center Operation & Maintenance YK OptiView Control Center Service Instructions SG O M O M1 Engineered Systems Group Product Service

2 SI0068 (104) OPTISAVE INSTALLATION Required for OptiSave installation: Administrator (Admin.) Access Level Password provided by Service Marketing or Product Service, specific to Software Version. Price Per kwh - provided by Service Sales, OptiSave Contract Specified Blended Utility kwh rate in U.S. Dollars (USD) as $0.00. VSD Design kwh - provided by Service Marketing, specific to Chiller. CSD Design kwh - provided by Service Marketing, specific to Chiller. It is recommended that the ACC EPROM software be the most current Version when installing the OptiSave software. Verify that the ACC EPROM is the most current software version - if not, update the ACC EPROM when installing the OptiSave software program. 1. Secure Chiller If chiller is running, shut down the chiller and allow post lube to time out. Secure the chiller by placing the OptiView panel manual Start/Stop control switch in the STOP (O) position. 2. Replace Software Program a. Remove power supply to VSD and control power to OptiView control panel via VSD disconnect or breaker. Remove preexisting Software Program from OptiView panel microboard. Install new Software Program with OptiSave program functionality: YT Chiller OptiSave Feature Microboards and Software Programs Microboard - Program Versions and Part Numbers: C.MLM and later (NEMA 1-4 chillers P/N ) C.MLM and later (CE Chillers P/N ) Microboard - Program Versions and Part Numbers: C.OPT.02.05A.301 and later (NEMA 1-4 & CE Chillers P/N ) YK Chiller OptiSave Feature Microboards and Software Programs Microboard Versions and Part Numbers: C.MLM and later (NEMA 1-4 Chillers P/N ) C.MLM and later (CE Chillers P/N ) Microboard Versions and Part Numbers: C.OPT.01.09A.301 and later (NEMA 1-4 & CE Chillers P/N ) b. Reapply the 115-vac control power to OptiView control panel and observe/verify software boot-up process to the Home Screen at the View access level. 3. Enable the OptiSave Feature a. Home Screen - Login with Administrator access level password, provided by Service Marketing ( ) or contact Aftermarket Product Service ( ) to request the daily Administrator access level password. The Admin. Password is software specific, you will need to provide the operating program software Version number (C.MLM.xx.yy.zzz) as found on the program card label or as displayed on the Diagnostics Screen (Service access level, navigate - Home > Setpoints > Setup > Diagnostics >), under the Software Versions heading and right of the Controls label. 2 YORK INTERNATIONAL

3 b. Operations Screen - Enable OptiSave feature, navigate to the Operations Screen (Home > Setpoints > Setup > Operations >), the OptiSave Enable/Disable feature key is located 3 rd from the lower left at the base of the Operations screen. Press the OptiSave setpoint key directly below the OptiSave label that will open the OptiSave Enable/Disable setpoint dialog box. Press the Previous or Next cursor arrow keys to toggle feature selection from the default Disabled to Enabled and then press the üenter check key to activate the OptiSave feature. To verify that the OptiSave feature is active, the setpoint displayed below the OptiSave label will read Enabled. Return to the Home Screen via the Home navigation key. Refer to the YT & YK Operations Screens supplement pages. 4. Programming the OptiSave Setpoints a. OptiSave Energy Analyzer Screen - Navigate to the new OptiSave Energy Analyzer screen (Home > Motor > OptiSave>). From the Home screen, navigate to the Motor screen. With the OptiSave feature Enabled there is a new OptiSave navigation key at the lower right of the Motor screen, press the OptiSave navigation key to the right of the OptiSave label. The new OptiSave Energy Analyzer screen has the following programmable setpoints displayed along the right side of the OptiSave screen: Price Per kwh, Home Screen Display, CSD Design kwh & VSD Design kwh. Refer to the OptiSave Energy Analyzer Screen supplement page. Refer to the OptiSave Setpoint Data and Calculated Data sections. b. Price Per kwh - Access level Service or higher to modify this setpoint. Press the setpoint key to right of the Price Per kwh label that will open the setpoint dialog box. Enter the OptiSave contract specified blended utility Price Per kwh in USD (0.00) format via the numeric keypad and then press the ü Enter check key. Verify that the programmed value has been accepted and is displayed to the right of the setpoint label. The minimum allowed value is 0.00 USD, the maximum allowed value is 9.99 USD, and the default value is 0.00 USD. If the Price Per kwh equals zero (0), the total USD savings will not be calculated or displayed. c. Home Screen Display Mode of Total Savings - Access level Service or higher to modify this setpoint. Press the setpoint key to right of the Home Screen Display label that will open the setpoint selection dialog box. Press the Previous or Next cursor arrow keys to toggle selection between the Energy (kwh) or USD (0.00) display modes and then press the ü Enter check key to activate the selected Total Savings mode displayed on the Home Screen. Verify that the programmed value has been accepted and is displayed to the right of the setpoint label. The default is Total Savings in USD (0.00). If the Price Per kwh is zero (0.00), the Total Energy Saved (kwh) shall be displayed on the Home Screen, regardless of the display mode selected, and the Total Savings in USD will not be calculated. d. CSD Design kw - Access level Administrator to modify this setpoint. Press the setpoint key to right of the CSD Design kw label that will open the setpoint dialog box. Enter the chiller specific CSD Design kw, provided by Service Marketing, via the numeric keypad and then press the ü Enter check key. Verify that the programmed value has been accepted and is displayed to the right of the setpoint label. The minimum allowed value is 0 kw, the maximum allowed value is 3000 kw, and the default value is 0 kw. If the CSD Design kw is 0 kw, the OptiSave feature will not function. e. VSD Design kw - Access level Administrator to modify this setpoint. Press the setpoint key to right of the VSD Design kw label that will open the setpoint dialog box. Enter the chiller specific VSD Design kw, provided by Service Marketing, via the numeric keypad and then press the ü Enter check key. Verify that the programmed value has been accepted and is displayed to the right of the setpoint label. The minimum allowed value is 0 kw, the maximum allowed value is 3000 kw, and the default value is 0 kw. If the VSD Design kw is 0 kw, the OptiSave feature will not function. f. VSD kwh Reset of the Variable Speed Meter - Access level Administrator to modify this setpoint. Resetting of the VSD kwh Meter is done ONLY when the OptiSave feature is first activated to clear any previous Variable Speed Meter kwh data and synchronize the Constant Speed and Variable YORK INTERNATIONAL 3

4 SI0068 (104) Speed Meters displays at zero (0). Press the setpoint key below the VSD kwh Reset label, 2 nd from lower left at the base of the screen, that will open the setpoint dialog box. Press the Default cursor arrow key to reset the Variable Speed Meter to zero (0) kwh and then press the ü Enter check key. Verify that the programmed value has been accepted and that zero (0) kwh is displayed to the left of the Variable Speed Meter display label. The minimum allowed value s 0 kw, the maximum allowed value is kw, and the default value is 0 kw g. Reverify that the above programmed setpoints are correctly displayed on the OptiSave Energy Analyzer screen and that the following displayed data are at zero (0): Constant Speed Meter, Variable Speed Meter, Last Full Calendar Month Savings & Total Energy Savings. Refer to the OptiSave Energy Analyzer Screen supplemental page. h. Return to the Home Screen via the Home navigation key. 5. Completing OptiSave Feature Setup a. Home Screen Verify that the OptiSave Total Savings label and data are displayed on the Home Screen, upper left above % Full Load Amps, in the mode (kwh or USD) as programmed in step 3.c and that the displayed value is zero. Refer to the Home Screens supplemental pages. b. Logout of the Administrator access level by pressing the key below the Logout label 3 rd from the lower left at the base of the screen. Verify access level is View. OptiSave installation is completed. 6. Verification of OptiSave Operation Access Level Required: View, Operator, or Service a. Verify OptiSave functionality by starting the chiller and returning it to normal operation for at least 30 minutes of run time. Home Screen- Monitor the displayed Total Savings value. (3) OptiSave Energy Analyzer Screen - (Home > Motor > OptiSave >) Monitor the following displayed values: Return Condenser Liquid Temperature (Input) (1) Input Power (Input) (2) Constant Speed Meter (3) Variable Speed Meter (2) Last Full Calendar Month Minimum Return Condenser Liquid Temperature (1) Last Full Calendar Month Savings (4) Total Energy Savings (3) Energy Cost USD per kwh (5). Total Savings USD (3) (1) Actual input value from Temperature Sensor. (2) Actual input value from VSD or Harmonic Filter. (3) Calculated Value, increments during chiller VSD operation. (4) Calculated value, increments >0 after first operating month. (5) Setpoint programmed value. OptiSave Energy Analyzer Graph Screen - (Home > Motor > OptiSave > Graph) Navigate to OptiSave Energy Analyzer Graph screen by pressing the Graph navigation key at the lower right of the OptiSave Energy Analyzer screen. Verify the OptiSave Energy Analyzer Graph screen operation by monitoring the CSD kwh and VSD kwh bars rising from the base of the graph it may take 20 or more minutes of run time for the graph bars to begin displaying. 4 YORK INTERNATIONAL

5 b. OptiSave Energy Analyzer Report Printing Verification Access level Operator or higher to print. If a printer has been setup for and is connected to the OptiView panel the OptiSave Energy Analyzer Report shall be available via the Print key on the OptiSave Energy Analyzer Screen. The OptiSave Energy Analyzer Report is a manual print report that is not available for Data Logging setup as an automatic printing report. See the REPORTS section for an example of the full data provided in this report. Refer to the Printer Section of the YT ( O1) and YK ( O1) Operating & Maintenance Manuals. c. OPTISAVE YorkTalk3 MicroGateway Verification - The OptiSave points available as YorkTalk3 data points are listed in the YT3 Object Type.Slot column of the input data tables in the OPTISAVE INPUT DATA section. For further York Talk3 and MicroGateway information, contact your local YORK Controls personnel. If you have questions or comments regarding the OptiSave software feature, contact: YORK Service Marketing ( ) or YORK Aftermarket Product Service ( ) OPTISAVE OPERATION OVERVIEW OPTISAVE Input Data Return Condenser Liquid Temperature This data is read from Return Condenser Liquid thermistor with a range of 8.0 F to F. Displayed on the OptiSave Energy Analyzer screen. Not printed in the OptiSave Energy Anaylzer report. YT3 Object Type.Slot is A1.4 RCNDL.Temp. Trend or Custom Screen Slot Number is VSD Input Power kw This data is supplied by the Variable Speed Drive or the optional Harmonic Filter, and is transmitted to the OptiView Chiller Control Panel once every two seconds. The range is 0 kw to 3020 kw. Displayed on the Opti- Save Energy Analyzer screen. Printed in the OptiSave Energy Analyzer report. YT3 Object Type.Slot is AV.71 VSD.INP.PWR. Trend or Custom Screen Slot Number is Coefficients The coefficients used in the OptiSave calculations are based on hundreds of random operating points having been derived from a representative number of chiller tonnages for each YT & YK chiller line. OPTISAVE SETPOINT DATA All OptiSave setpoint values are written to the BRAM. Enable / Disable OptiSave Feature Select to Enable or Disable the OptiSave feature. The Access level is Administrator to modify this setpoint. The default value is Disabled. If the OptiSave feature is Disabled, the navigation key on the Motor Screen to jump to the OptiSave Energy Analyzer Screen shall be disabled. YT3 Object Type.Slot is AO.31 OS.ENABLE. Trend or Custom Screen Slot Number is If the feature is Enabled, but the VSD Design kw or the CSD Design kw equals zero (0) the feature will not function. If the Price Per kwh equals zero (0), the total USD savings will not be calculated or displayed. Displayed on the Operations screen. Not printed in the OptiSave Energy Analyzer report. Price Per kwh Enter the OptiSave contract specified blended utility Price Per kwh. The Access Level is Service or higher to modify this setpoint. The minimum allowed value is 0.00 USD, the maximum allowed value is 9.99 USD, and the YORK INTERNATIONAL 5

6 default value is 0.00 USD. If the Price Per kwh equals zero (0), the total USD savings will not be calculated or displayed. Displayed on the OptiSave Energy Analyzer screen. Printed in the OptiSave Energy Analyzer Setpoints report. YT3 Object Type.Slot is AO.34 OS.PRICE.KWH. Trend or Custom Screen Slot Number is CSD Design kw Enter the chiller specific CSD Design kw as provided by York Service Marketing at the time of chiller or VSD commissioning. The Access Level shall be Administrator in order to modify this setpoint. The minimum allowed value is 0 kw, the maximum allowed value is 3000 kw, and the default value is 0 kw. If the CSD Design kw is 0 kw, the OptiSave feature will not function. Displayed on the OptiSave Energy Analyzer screen. Printed in the OptiSave Energy Analyzer Setpoints report. YT3 Object Type.Slot is AO.33 OS.CSD.DESGN. Trend or Custom Screen Slot Number is VSD Design kw Enter the chiller specific VSD Design kw as provided by York Service Marketing at the time of chiller or VSD commissioning. The Access Level is Administrator to modify this setpoint. The minimum allowed value is 0 kw, the maximum allowed value is 3000 kw, and the default value is 0 kw. If the VSD Design kw is 0 kw, the OptiSave feature will not function. Displayed on the OptiSave Energy Analyzer Setpoints screen. Printed in the OptiSave Energy Analyzer Setpoints report. YT3 Object Type.Slot is AO.32 OS.VSD.DESGN. Trend or Custom Screen Slot Number is Home Screen Total Savings Display Mode Select either the Total Energy Saved (kwh) or the Total Savings (USD) to be displayed on the Home Screen. The Access Level is Service or higher to modify this setpoint. The default is Total Savings in USD. If the Price Per kwh is zero (0), the Total Energy Saved (kwh) shall be displayed on the Home Screen, regardless of the mode selected, and the Total Savings in USD will not be calculated. Displayed on the OptiSave Energy Analyzer Setpoints screen. Printed in the OptiSave Energy Analyzer Setpoints report. YT3 Object Type.Slot is AO.35 OS.DISP.MODE. Trend or Custom Screen Slot Number is OPTISAVE CALCULATED DATA The following calculations are performed every two seconds while the chiller is running, if the OptiSave feature is enabled, the VSD Design kw is not zero (0), the CSD Design kw is not zero (0), and the Return Chilled Liquid Temperature sensor is in range: The CSD Input Power The Constant Speed Meter The Total Energy Savings is calculated - the Total Energy Savings is not allowed to exceed ± kwh (but will NOT roll over). All OptiSave calculated data values are written to the BRAM including the data index point, the Julian time of the last data point, and the running sum as applicable: Hourly Average Return Condenser Liquid Temperature (x24 hours) The Hourly Return Condenser Liquid Temperature values for the past 24 hours shall be stored in BRAM, using a FIFO scheme. Printed in the OptiSave Energy Analyzer report. Trend or Custom Screen Slot Numbers are Daily Average Return Condenser Liquid Temperature (x30 days) The Daily Average Return Condenser Liquid Temperature values for the past 30 days shall be stored in BRAM, using a FIFO scheme. Printed in the OptiSave Energy Analyzer report. Trend or Custom Screen Slot Numbers are Monthly Average Return Condenser Liquid Temperature (x12 months) The Monthly Average Return Condenser Liquid Temperature values for the past 12 months shall be stored in BRAM, using a FIFO scheme. Printed in the OptiSave Energy Analyzer report. YT3 Object Type.Slot is AO.6 AO.17 OS.RTCD.Mx. Trend or Custom Screen Slot Numbers are Yearly Average Return Condenser Liquid Temperature (x20 years) The Yearly Average Return Condenser Liquid Temperature values for the past 20 years shall be stored in BRAM, 6 YORK INTERNATIONAL

7 using a FIFO scheme. Printed in the OptiSave Energy Analyzer report. Trend or Custom Screen Slot Numbers are Hourly Minimum Return Condenser Liquid Temperature (x24 hours) The Return Condenser Liquid Temperature shall be read every second, and compared to the last minimum value. If it is less than the last minimum value, the last minimum value shall be set to the current temperature reading. The Minimum Return Condenser Liquid Temperature value for each of the past 24 hours shall be stored in BRAM, using a FIFO scheme. Printed in the OptiSave Energy Analyzer report. Trend or Custom Screen Numbers Daily Minimum Return Condenser Liquid Temperature (x30 days) When the calendar day changes, the last 24 Hourly Minimum Return Condenser Liquid Temperatures shall be examined for the minimum value for that day. The Minimum Return Condenser Liquid Temperature value for each of the past 30 days shall be stored in BRAM, using a FIFO scheme. Printed in the OptiSave Energy Analyzer report. Trend or Custom Screen Numbers Monthly Minimum Return Condenser Liquid Temperature (x12 months) When the calendar month changes, the last 30 Daily Minimum Return Condenser Liquid Temperatures shall be examined for the minimum value for that month. The Minimum Return Condenser Liquid Temperature value for each of the past 12 months shall be stored in BRAM, using a FIFO scheme. Displayed on the OptiSave Energy Analyzer Screen. Printed in the OptiSave Energy Analyzer report. YT3 Object Type.Slot is AO.36-AO.47 OS.MRTCD.Mx. Trend or Custom Screen Numbers Yearly Minimum Return Condenser Liquid Temperature (x20 years) When the calendar year changes, the last 12 Monthly Minimum Return Condenser Liquid Temperatures shall be examined for the minimum value for that year. The Minimum Return Condenser Liquid Temperature value for each of the past 20 years shall be stored in BRAM, using a FIFO scheme. Printed in the OptiSave Energy Analyzer report. Trend or Custom Screen Numbers CSD kwh Meter The cumulative amount of kilowatts (kwh) calculated that would have been used by a Constant Speed motor controller. The CSD kwh Meter cumulative value shall be stored in BRAM and will automatically roll over when it exceeds The value of the CSD kwh Meter can be modified at the Administrator Access Level on the OptiSave Energy Analyzer Data Screen. Displayed on the OptiSave Energy Analyzer, OptiSave Energy Analyzer Data and the OptiSave Energy Analyzer Graph screens. Printed in the OptiSave Energy Analyzer and the OptiSave Energy Setpoints reports. YT3 Object Type.Slot is AO.4 OS.CSD.KWH. Trend or Custom Screen Slot Number is VSD kwh Meter The cumulative amount of actual kilowatts (kwh) used as the VSD motor controller operates. The VSD kwh Meter cumulative value shall be stored in BRAM and will automatically roll over when it exceeds The value of the VSD kwh Meter can be modified at the Administrator Access Level on the OptiSave Energy Analyzer Data Screen. Displayed on the OptiSave Energy Analyzer, the OptiSave Energy Analyzer Data and the OptiSave Energy Analyzer Graph screens. Printed in the OptiSave Energy Analyzer and the OptiSave Energy Analyzer Setpoints reports. YT3 Object Type.Slot is AO.5 OS.VSD.KWH. Trend or Custom Screen Slot Number is Total Energy Savings The cumulative calculated amount of kwh saved in using a Variable Speed Drive vs. a Constant Speed Drive. The Total Saved Energy cumulative value shall be stored in BRAM, the maximum value that the Total Saved Energy can reach is 999,999,999 kwh for the lifetime of the chiller. The value of the Total Saved Energy can be modified at the Administrator Access Level on the OptiSave Energy Analyzer Data Screen. Displayed on the Home (Energy display mode), the OptiSave Energy Analyzer and the OptiSave Energy Analyzer Data screens. Printed in OptiSave Energy Analyzer and the OptiSave Energy Analyzer Setpoints reports. YT3 Object Type.Slot is AO.2 OS.TOTAL. Trend or Custom Screen Slot Number is Hourly Total Saved Energy (x24 hours) The Hourly Total Saved Energy values read on every hour for the past 24 hours shall be stored in BRAM, using a FIFO scheme. Printed in the OptiSave Energy Analyzer report. Trend or Custom Screen Slot Numbers are YORK INTERNATIONAL 7

8 Daily Total Saved Energy (x30 days) The Daily Total Saved Energy values read at midnight of every day for the past 30 days shall be stored in BRAM, using a FIFO scheme. Printed in the OptiSave Energy Analyzer report. Trend or Custom Screen Slot Numbers are Monthly Total Saved Energy (x12 months) The Monthly Total Saved Energy values is constantly updated during the current month until midnight of the last day of the month. The month-end values for every month for the past 12 months shall be stored in BRAM, using a FIFO scheme. The value of the Monthly Total Saved Energy for the preceding 11 months can be modified at the Administrator Access Level on the OptiSave Energy Analyzer Data Screen. Printed in the OptiSave Energy Analyzer and the OptiSave Energy Analyzer Setpoints reports. YT3 Object Type.Slot is AO.128 AO.29 OS.ENERGY.Mx. Trend or Custom Screen Slot Numbers are Yearly Total Saved Energy (x20 years) The Yearly Total Saved Energy values read at midnight of the last day of every year for the past 20 years shall be stored in BRAM, using a FIFO scheme. Printed in the OptiSave Energy Analyzer report. Trend or Custom Screen Slot Numbers are Total Savings In USD The Total Saved Energy shall be multiplied by the Cost Per kwh to compute the Total Savings in USD. Displayed on the Home (Savings display mode) and OptiSave Energy Analyzer screens. Printed in OptiSave Energy Analyzer report. YT3 Object Type.Slot is AO.3 OS.DOLLARS. Trend or Custom Screen Slot Number is Last Full Calendar Month Savings Value of the Monthly Total Saved Energy for the month prior to the present month. Displayed on the Opti- Save Energy Analyzer Screen. Printed in the OptiSave Energy Analyzer report. YT3 Object Type.Slot is AO.30 OS.ENRGY.ML. Trend or Custom Screen Number Last Full Calendar Month Minimum Return Condenser Liquid Temperature Value of the Monthly Minimum Return Condenser Liquid Temperature for the month prior to the present month. Displayed on the OptiSave Energy Analyzer Screen. Printed in the OptiSave Energy Analyzer report. YT3 Object Type.Slot is AO.48 OS.MRTCD.ML. Trend or Custom Screen Number OPTISAVE DATA RESETS CSD kwh Reset Allows user to modify the cumulative Constant Speed Meter value. The Access Level shall be Administrator in order to modify this value. Used when BRAM is replaced or cleared to manually reenter prior value. Do Not Reset arbitrarily OptiSave data may be compromised. Modified on the OptiSave Energy Analyzer Data screen. Press the setpoint key below the CSD kwh Reset label, 1 st from lower left at the base of the screen, that will open the setpoint dialog box. Enter the desired Constant Speed Meter value (kwh) via the numeric keypad and then press the PEnter check key. Verify that the programmed value has been accepted and is displayed to the left of the Constant Speed Meter display label. The minimum allowed value is 0 kwh, the maximum allowed value is kwh, and the default value is 0 kwh. VSD kwh Reset Allows user to modify the cumulative Variable Speed Meter value. The Access Level shall be Administrator in order to modify this value. Used when BRAM is replaced or cleared to manually reenter prior value. Do Not Reset arbitrarily OptiSave data may be compromised. Modified on the OptiSave Energy Analyzer Data screen. Press the setpoint key below the VSD kwh Reset label, 2 nd from lower left at the base of the screen, that will open the setpoint dialog box. Enter the desired Variable Speed Meter value (kwh) via the numeric keypad and then press the Enter check key. Verify that the programmed value has been accepted and is displayed to the left of the Variable Speed Meter display label. The minimum allowed value is 0 kwh, the maximum allowed value is kwh, and the default value is 0 kwh. Total Savings Reset Allows user to modify the cumulative Total Energy Savings value. The Access Level shall be Administrator in order to modify this value. Used when BRAM is replaced or cleared to manually reenter prior value. Do 8 YORK INTERNATIONAL

9 Not Reset arbitrarily OptiSave data may be compromised. Modified on the OptiSave Energy Analyzer Data screen. The CSD Design kw and VSD Design kw Setpoints must be programmed prior to resetting the Total Savings. If either the CSD Design or VSD Design kw value is zero the Total Savings value cannot be reset. Press the setpoint key below the Total Savings Reset label, 3 rd from lower left at the base of the screen, that will open the setpoint dialog box. Enter the desired Total Savings value (kwh) via the numeric keypad and then press the PEnter check key. Verify that the programmed value has been accepted and is displayed to the left of the Total Energy Savings display label. The minimum allowed value is kwh, the maximum allowed value is kwh, and the default value is 0 kwh. Monthly Total Saved Energy Meter (x11 months) Allows user to modify the cumulative Monthly Total Saved Energy Meter values for the preceding 11 months. The current Month Savings cannot be modified. The Access Level shall be Administrator in order to modify these values. Used when BRAM is replaced or cleared to manually reenter prior value. Do Not Reset arbitrarily OptiSave data may be compromised. Modified on the OptiSave Energy Analyzer Data screen. Press the setpoint key to the right of the Select label, 3 rd from the top at the right side of the screen, that will open a Green cursor box around the upper (current Month) Monthly Total Energy Meter Reading value box. Press the Up or Down cursor arrow keys to move the Green cursor box to the desired Month value to be modified. Press the PEnter check key to open the value selection dialog box. Enter the desired Month Total Energy Meter value (kwh) via the numeric keypad and then press the PEnter check key. Verify that the programmed value has been accepted and is displayed to the right of the selected Month display label. Repeat as required to select and reset the Monthly Total Energy Meter Reading values. The minimum allowed value s kwh, the maximum allowed value is kwh, and the default value is 0 kwh. Press the Ñ Cancel cursor key to exit the Monthly Total Energy Meter Reading reset mode. COMPLETE OPTISAVE DATA RESETS Logout of the Administrator access level by pressing the key below the Logout label 3 rd from the lower left at the base of the Home screen. Verify access level is View. OPTISAVE CONTROLS Data Corrections On Power Up The hourly, daily, monthly, and yearly averages and totals are adjusted for any time that has elapsed while the control panel was powered off. Array points corresponding to the time during which the panel was powered off are filled with default data. Data Corrections When The Time Or Date Are Modified Because the hourly, daily, monthly, and yearly averages and totals are performed based on calendar time, adjustments are made if the user changes the time or date of the control panel. To limit the effect of changing the time and/or date, twice the required array elements are stored (i.e. save 48 hours, 60 days, 24 months, etc.) in a circular queue. The head of the queue is moved so that it points to the element whose Julian date stamp most closely matches the time and date currently read from the panel. However, it is still possible that data may be lost with this method. In the case of lost data, those array elements are filled with default data. Do Not Reset Time or Date arbitrarily, OptiSave data may be compromised. BRAM Replacement or Clearing If the microboard BRAM is replaced or is cleared, the following OptiSave setpoints and data would need to be manually captured prior to the BRAM being replaced or cleared and re-entered afterward from the OptiSave Energy Analyzer and OptiSave Energy Analyzer Data screens: Enable OptiSave Price Per kwh VSD Design kw CSD Design kw YORK INTERNATIONAL 9

10 Home Screen Display VSD kwh Meter CSD kwh Meter Total Saved Energy Monthly Total Energy Saved Meter (x12 months) The above setpoint values, except Enable OptiSave, may be captured via the OptiSave Energy Analyzer Setpoints print report or read from the OptiSave Energy Analyzer Data screen at the Administrator access level. The following OptiSave information stored in BRAM would be permanently lost: Hourly Average Return Condenser Liquid Temperature (x24 hours) Daily Average Return Condenser Liquid Temperature (x30 days) Monthly Average Return Condenser Liquid Temperature (x12 months) Yearly Average Return Condenser Liquid Temperature (x20 years) Hourly Minimum Return Condenser Liquid Temperature (x24 hours) Daily Minimum Return Condenser Liquid Temperature (x30 days) Monthly Minimum Return Condenser Liquid Temperature (x12 months) Yearly Minimum Return Condenser Liquid Temperature (x20 years) Hourly Total Saved Energy (x24 hours) Daily Total Saved Energy (x30 days) Yearly Total Saved Energy (x20 years) Last Full Calendar Month Savings Last Full Calendar Month Minimum Return Condenser Liquid Temperature The above data will again begin to be recalculated and stored in BRAM afterward and going forward. Do Not replace or clear BRAM arbitrarily, OptiSave data may be compromised. Software Program Software Replacement Installing an earlier software program without the OptiSave feature: OptiSave specific data values are written to the BRAM. Should an OptiSave featured software program be replaced with an earlier non-optisave software version the OptiSave feature will not be available. The OptiSave data values previously stored in the BRAM will remain intact at the point when the OptiSave featured software was removed. OptiSave data will not be calculated or updated while the non-optisave software version is installed. Should a later OptiSave featured software program be reinstalled and the OptiSave feature re-enabled the prior OptiSave data in the BRAM will be read by the software and displayed on the OptiSave Energy Analyzer screen. The OptiSave data will be calculated and incremented going forward as the VSD motor controller operates and the OptiSave feature is Enabled. Installing a later OptiSave featured software program: OptiSave specific data values are written to the BRAM. Should a later version OptiSave featured software program be installed the prior OptiSave data in the BRAM will be read by the software and displayed on the OptiSave Energy Analyzer screen. Manual re-enabling of the OptiView feature is unnecessary as later version OptiView featured software will recognize the OptiSave feature was previously enabled. The OptiSave data will be calculated and incremented going forward as the VSD motor controller operates and the OptiSave feature is Enabled. 10 YORK INTERNATIONAL

11 OPTISAVE DATA Input Data - Analog Title Lowest Displayed Value Highest Displayed Value Return Condenser Liquid Temperature 8.0 F F Input Data Serial Communications Title Lowest Displayed Value Highest Displayed Value VSD Input Power 0 kw kw Programmable Data Lowest Highest Access Level Default Title Allowed Value Allowed Value Total Energy Savings Administrator 0 kwh kwh kwh Constant Speed Meter Administrator 0 kwh 0 kwh kwh Variable Speed Meter Administrator 0 kwh 0 kwh kwh OptiSave [Enable] Administrator Disabled Disabled à Enabled VSD Design kw Administrator 0 kw 0 kw 3000 kw CSD Design kw Administrator 0 kw 0 kw 3000 kw Price Per kwh Service 0.00 USD 0.00 USD 9.99 USD Home Screen Display Service Dollars Energy (kwh) à Dollars (USD) YT3 Object Type.Slot AI.4 RCNDL.TEMP YT3 Object Type.Slot AV.71 VSD.INP.PWR YT3 Object Type.Slot AO.2 OS.TOTAL AO.4 OS.CSD.KWH AO.5 OS.VSD.KWH AO.31 OS.ENABLE AO.32 OS.VSD.DESGN AO.33 OS.CSD.DESGN AO.34 OS.PRICE.KWH AO.35 OS.DISP.MODE Derived Data Title Lowest Highest Displayed YT3 Object Displayed Value Value Type.Slot Total Energy Savings kwh kwh AO.2 OS.TOTAL Total Savings In USD USD USD AO.3 OS.DOLLARS Constant Speed Meter 0 kwh kwh AO.4 OS.CSD.KWH Variable Speed Meter 0 kwh kwh AO.5 OS.VSD.KWH Hourly Average Return Condenser Liquid Temperature (x24 hours) 8.0 F F Not Available Daily Average Return Condenser Liquid Temperature (x31 days) 8.0 F F Not Available Monthly Average Return Condenser Liquid AO.6 - AO F F Temperature (x12 months) OS.RTCD.Mx Yearly Average Return Condenser Liquid Temperature (x20 years) 8.0 F F Not Available Hourly Minimum Return Condenser Liquid Temperature (x24 hours) 8.0 F F Not Available Daily Minimum Return Condenser Liquid Temperature (x31 days) 8.0 F F Not Available Monthly Minimum Return Condenser Liquid AO.36 - AO F F Temperature (x12 months) OS.MRTCD.Mx Yearly Minimum Return Condenser Liquid Temperature (x20 years) 8.0 F F Not Available Hourly Total Saved Energy (x24 hours) kwh kwh Not Available Daily Total Saved Energy (x31 days) kwh kwh Not Available AO.18 - AO.29 Monthly Total Saved Energy (x12 months) kwh kwh OS.ENRGY.Mx Yearly Total Saved Energy (x20 years) kwh kwh Not Available AO.30 Last Full Calendar Month Savings kwh kwh OS.ENRGY.ML Last Full Calendar Month Minimum Return Condenser AO F F Liquid Temperature OS.MRTCD.ML YORK INTERNATIONAL 11

12 OPTISAVE YORKTALK3 PARAMETERS The OptiSave points available as YorkTalk3 data points are listed in the preceding OptiSave data tables in the YT3 Object Type.Slot column. While the communications protocol is not limited to a specific number of digits that can be transmitted, the ISN Panel Display is limited to 4 numeric positions. OPTISAVE TREND OR CUSTOM SCREEN SLOT NUMBERS DESCRIPTION OPTISAVE SLOT # Constant Speed Meter 3842 CSD Design kw 3844 CSD Input Power 3850 Daily Average Return Condenser Liquid Temperature (x31 days) Daily Total Saved Energy (x31 days) Daily Total Saved Energy (x31 days) Home Screen Display 3847 Hourly Average Return Condenser Liquid Temperature (x24 hours) Hourly Minimum Return Condenser Liquid Temperature (x24 hours) Hourly Total Saved Energy (x24 hours) Last Full Calendar Month Savings 4066 Last Full Calendar Month Minimum Return Condenser Liquid Temperature 3671 Monthly Average Return Condenser Liquid Temperature (x12 months) Monthly Minimum Return Condenser Liquid Temperature (x12 months) Monthly Total Saved Energy (x12 months) OptiSave [Enable] 3840 Price Per kwh 3846 Return Condenser Liquid Temperature 2051 Total Energy Savings 3845 Total Savings In USD 3849 Variable Speed Meter 3841 VSD Design kw 3843 VSD Input Power 2818 Yearly Average Return Condenser Liquid Temperature (x20 years) Yearly Minimum Return Condenser Liquid Temperature (x20 years) Yearly Total Saved Energy (x20 years) REPORTS Setpoint Report The following OptiSave setpoints are included in the Setpoint Report, if the OptiSave feature is enabled: OptiSave [Enable] VSD Design kw CSD Design kw Price Per kwh Home Screen Display 12 YORK INTERNATIONAL

13 Slot List Report The following OptiSave slots are included in the Slot List Report, if the OptiSave feature is enabled: Constant Speed Meter Variable Speed Meter Total Energy Savings Total Savings In USD Last Full Calendar Month Savings Last Full Calendar Month Minimum Return Condenser Liquid Temperature OptiSave Energy Analyzer Report This report is available manually via the Print key on the OptiSave Energy Analyzer Screen at the Operator or higher access level. The OptiSave Energy Analyzer Report prints the following information: YORK OptiSave Energy Analyzer Report Chiller ID 0 (c) YORK INTERNATIONAL CORPORATION Mon 24 Feb :50:45 AM Controls C.MLM Run Time 0 Days 2 Hr 59 Min Operating Hours = 25 Hr Number Of Starts = 6 Input Power = 68 KW Variable Speed Meter = KWH CSD Input Power = 74 KW Constant Speed Meter = KWH Total Energy Savings = KWH Total Dollar Savings = USD Last Full Calendar Month Savings = 0 KWH Last Full Calendar Month Minimum Return Con = 65.0 ~F Hourly Average Return Condenser Liquid Temperature Feb :50:45 AM = 65.0 ~F 24 Feb :59:59 AM = 65.0 ~F 24 Feb :59:59 AM = 65.0 ~F Daily Average Return Condenser Liquid Temperature Feb :50:45 AM = 65.0 ~F 23 Feb :59:59 PM = 65.0 ~F 22 Feb :59:59 PM = 65.0 ~F Monthly Average Return Condenser Liquid Temperature Feb :50:45 AM = 65.0 ~F 31 Jan :59:59 PM = 65.0 ~F 31 Dec :59:59 PM = 65.0 ~F Yearly Average Return Condenser Liquid Temperature Feb :50:45 AM = 65.0 ~F 31 Dec :59:59 PM = 65.0 ~F 31 Dec :59:59 PM = 65.0 ~F Hourly Minimum Return Condenser Liquid Temperature Feb :50:45 AM = 65.0 ~F 24 Feb :59:59 AM = 65.0 ~F 24 Feb :59:59 AM = 65.0 ~F YORK INTERNATIONAL 13

14 OptiSave Energy Analyzer Report - Continued Daily Minimum Return Condenser Liquid Temperature Feb :50:45 AM = 65.0 ~F 23 Feb :59:59 PM = 65.0 ~F 22 Feb :59:59 PM = 65.0 ~F Monthly Minimum Return Condenser Liquid Temperature Feb :50:45 AM = 65.0 ~F 31 Jan :59:59 PM = 65.0 ~F 31 Dec :59:59 PM = 65.0 ~F Yearly Minimum Return Condenser Liquid Temperature Feb :50:45 AM = 65.0 ~F 31 Dec :59:59 PM = 65.0 ~F 31 Dec :59:59 PM = 65.0 ~F Hourly Total Saved Energy Feb :50:45 AM = 452 KWH 24 Feb :59:59 AM = 452 KWH 24 Feb :59:59 AM = 452 KWH Daily Total Saved Energy Feb :50:45 AM = 1848 KWH 23 Feb :59:59 PM = 1848 KWH 22 Feb :59:59 PM = 1848 KWH Monthly Total Saved Energy Feb :50:45 AM = KWH 31 Jan :59:59 PM = KWH 31 Dec :59:59 PM = KWH Yearly Total Saved Energy Feb :50:45 AM = KWH 31 Dec :59:59 PM = KWH 31 Dec :59:59 PM = KWH 14 YORK INTERNATIONAL

15 OptiSave Energy Analyzer Setpoints Report This report is available manually via the Print key on the OptiSave Energy Analyzer Data Screen - at the Administrator access level. The OptiSave Energy Analyzer Setpoints Report prints the following information: YORK OptiSave Energy Analyzer Setpoints Report Chiller ID 0 (c) YORK INTERNATIONAL CORPORATION Mon 24 Feb :50:45 AM Controls C.MLM CSD Design KWH = 129 KWH VSD Design KWH = 134 KWH Price Per KWH = 0.05 USD Home Screen Display = Energy Constant Speed Meter Variable Speed Meter Total Energy Savings = KWH = 8978 KWH = 1511 KWH Feb = 000 KWH Jan = 679 KWH Dec = 159 KWH Nov = 079 KWH OCT = 000 KWH Sep = 000 KWH Aug = 000 KWH Jul = 000 KWH JUN = 000 KWH May = 000 KWH Apr = 000 KWH Mar = 000 KWH YORK INTERNATIONAL 15

16 HOME SCREEN YT OPTISAVE "OptiSave" Total Savings Data Display OVERVIEW When the chiller system is powered on, the above default display appears. The primary values which must be monitored and controlled are shown on this screen. The Home Screen display depicts a visual representation of the chiller itself. Animation indicates chilled liquid flow. DISPLAY ONLY Chilled Liquid Temperature - Leaving Displays the temperature of the liquid as it leaves the evaporator. Chilled Liquid Temperature - Return Displays the temperature of the liquid as it enters the evaporator. Condenser Liquid Temperature - Leaving Displays the temperature of the liquid as it leaves the condenser. Condenser Liquid Temperature - Return Displays the temperature of the liquid as it enters the condenser. Motor Run (LED) Is ON when the digital output controlling the Motor Starter contact is on. Input Power (kw) Available only if the chiller system is utilizing a Variable Speed Drive motor controller or Mod B Solid State Starter. This displays the total input power used by the system. Total Savings (Software versions C.MLM xxx or C.OPT.02.05A.xxx and later) Available only if utilizing a Variable Speed Drive motor controller and the OptiSave feature is enabled. Displays the OptiSave calculated VSD Total Savings as Energy (kwh) or Dollars (USD). The data type displayed is determined by the OptiSave Home Screen Total Savings Display Mode and Price Per kwh setpoints. % Full Load Amps This displays the percentage of full load amps utilized by the system. Operating Hours Displays the cumulative operating hours of the chiller. PROGRAMMABLE Login 16 YORK INTERNATIONAL

17 The Control Center restricts certain operations based on password entry by the operator. Three different access levels are provided as follows: VIEW: The panel defaults to the lowest access level which is termed VIEW. In this mode, the chiller operating values and setpoints can be observed, but no changes can be made. OPERATOR: The second access level is termed OPERATOR and will allow the customer to change all of the setpoints required to operate the chiller system. The OPERATOR access level reverts to the VIEW level after 10 continuous minutes without a keypress. SERVICE: In the event that advanced diagnostics are necessary, a SERVICE access level has been provided. Only qualified service personnel utilize this access level. This level provides advanced control over many of the chiller functions and allows calibration of many of the chiller controls. The access levels are listed above in hierarchical order beginning with the lowest level and proceeding to the highest level. Users logged in under higher access levels may perform any actions permitted by lower access levels. The OPERATOR access level is accompanied by a 10-minute timeout. After ten (10) successive minutes without a keypress, the panel will revert to the VIEW access level. This prevents unauthorized changes to the chiller if a user was logged in at a higher access level and failed to logout. Proper procedure requires that after making necessary setpoint adjustments the user return to the Home Screen and logout. Logout Access Level Required: OPERATOR This key is displayed when a user is logged in at any level other than VIEW. Pressing it will return the access level to VIEW. Print Use this key to generate a hard-copy report of the present system status. This provides a snapshot of the primary operating conditions at the time the key is pressed. The History page provides enhanced reporting capability. (See HISTORY below.) This option will not be present if the chiller is presently configured to log any incoming Adaptive Capacity Control map points. (See the Adaptive Capacity Control Details screen.) Message Clear Access Level Required: SERVICE When certain safety or cycling conditions have been detected and the chiller has been shutdown, the main status display of the chiller will continue to display a message indicating the cause of the shutdown. Using this key, the message can be cleared once the condition has been removed. Warning Reset Access Level Required: OPERATOR Use of this key acknowledges a warning condition and resets the message display associated with it. NAVIGATION System Used to provide additional system information. Evaporator A detailed view of all evaporator parameters, including the programmable Leaving Chilled Liquid Setpoints. Condenser A detailed view of all condenser parameters, including control of the purge functions. Compressor A detailed view of all the compressor parameters. This includes pre-rotation vane control, Hot Gas Bypass Control and PRV calibration. Oil Sump A detailed view of all the oil pump and oil sump parameters. Motor A detailed view of the motor controller parameters, specific to the controller type presently utilized on the chiller system. This allows programming of the Current Limit and the Pulldown Demand Limit values. For a VSD system, the Adaptive Capacity Control and Harmonic Filter and OptiSave feature information is controlled under this screen. Setpoints This screen provides a single location to program the most common system setpoints. It is also the gateway to many of the general system setup parameters such as Date/Time, Display Units, Scheduling, Printer Setup, etc. History This screen provides access to a snapshot of system data at each of the last 10 shutdown conditions. OVERVIEW This screen allows definition of general parameters having to do with the operation of the chiller. YORK INTERNATIONAL 17

18 OPERATIONS SCREEN YT OPTISAVE "OptiSave" Enabled/Disabled Setpoint DISPLAY ONLY Chiller Run Time (Software version C.MLM or later) Displays the amount of time the chiller has been running since the last start signal was received. Value is reset to zero when the chiller enters Coastdown. It remains at zero while shutdown and during System Prelube. PROGRAMMABLE Control Source Access Level Required: OPERATOR Define whether the control of the chiller will be Local, Digital Remote, Analog Remote, Modem Remote or ISN Remote. Number of Starts Access Level Required: ADMIN Displays the number of the starts the chiller has initiated. This may be reprogrammed to a desired value, (generally when this value has been reset due to a Microboard replacement), but should not be done so arbitrarily. Operating Hours Access Level Required: ADMIN Displays the total accumulated run time of the chiller. This may be reprogrammed to a desired value (generally when this value has been reset due to a Microboard replacement), but should not be done so arbitrarily. Hot Gas Bypass (Enabled/Disabled) Access level required: SERVICE Enables and disables the hot gas bypass feature. Refrigerant Level Control (Enabled/Disabled) Access Level Required: SERVICE Enables and Disables the Refrigerant Level Control feature. OptiSave VSD Feature (Enabled/Disabled) (Software versions C.MLM xxx or C.OPT.02.05A.xxx and later) Access Level Required: ADMIN Available only if utilizing a Variable Speed Drive motor controller. Enables and Disables the OptiSave VSD feature. If the OptiSave feature is Disabled, the OptiSave navigation key on the Motor/VSD Screen is not displayed and the Total Savings will not be displayed on the Home screen. 18 YORK INTERNATIONAL

19 Service Phone Numbers (Software version C.MLM xxx and later) Access Level Required: SERVICE Displays up to two service phone numbers. The Regional service phone number is displayed as the first number. Although the label and number can be changed appropriately, the default for this entry is York Intl North American Toll Free Number The Local service phone number is displayed as the second number. Although blank by default, the appropriate label and number can be entered by a Service Technician. Service Technicians refer to Service Manual M1. NAVIGATION Home Causes an instant return to the Home Screen. Setup Return to the Setup Screen. YORK INTERNATIONAL 19

20 HOME SCREEN YK OPTISAVE "OptiSave" Total Savings Data Display OVERVIEW When the chiller system is powered on, the above default display appears. The primary values which must be monitored and controlled are shown on this screen. The Home Screen display depicts a visual representation of the chiller itself. Animation indicates chilled liquid flow. DISPLAY ONLY Chilled Liquid Temperature - Leaving Displays the temperature of the liquid as it leaves the evaporator. Chilled Liquid Temperature - Return Displays the temperature of the liquid as it enters the evaporator. Condenser Liquid Temperature - Leaving Displays the temperature of the liquid as it leaves the condenser. Condenser Liquid Temperature - Return Displays the temperature of the liquid as it enters the condenser. Motor Run (LED) Is ON when the digital output controlling the Motor Starter contact is on. Input Power (kw) Available only if the chiller system is utilizing a Variable Speed Drive or Mod B Solid State Starter motor controller. This displays the total input power used by the system. Total Savings (Software versions C.MLM xxx or C.OPT.01.09A.xxx and later) Available only if utilizing a Variable Speed Drive motor controller and the OptiSave feature is enabled. Displays the OptiSave calculated VSD Total Savings as Energy (kwh) or Dollars (USD). The data type displayed is determined by the OptiSave Home Screen Total Savings Display Mode and Price Per kwh setpoints. % Full Load Amps This displays the percentage of full load amps utilized by the system. Operating Hours Displays the cumulative operating hours of the chiller. PROGRAMMABLE Login The OptiView Panel restricts certain operations based on password entry by the operator. Three different ac- 20 YORK INTERNATIONAL

21 cess levels are provided as follows: VIEW: The panel defaults to the lowest access level which is termed VIEW. In this mode, the chiller operating values and setpoints can be observed, but no changes can be made. OPERATOR: The second access level is termed OPERATOR and will allow the customer to change all of the setpoints required to operate the chiller system. The OPERATOR access level reverts to the VIEW level after 10 continuous minutes without a keypress. SERVICE: In the event that advanced diagnostics are necessary, a SERVICE access level has been provided. Only qualified service personnel utilize this access level. This level provides advanced control over many of the chiller functions and allows calibration of many of the chiller controls. The access levels are listed above in hierarchical order beginning with the lowest level and proceeding to the highest level. Users logged in under higher access levels may perform any actions permitted by lower access levels. The OPERATOR access level is accompanied by a 10-minute timeout. After ten (10) successive minutes without a keypress, the panel will revert to the VIEW access level. This prevents unauthorized changes to the chiller if a user was logged in at a higher access level and failed to logout. Proper procedure requires that after making necessary setpoint adjustments the user return to the Home Screen and logout. Logout Access Level Required: OPERATOR This key is displayed when a user is logged in at any level other than VIEW. Pressing it will return the access level to VIEW. Print Use this key to generate a hard-copy report of the present system status. This provides a snapshot of the primary operating conditions at the time the key is pressed. The History page provides enhanced reporting capability. (See HISTORY below.) This option will not be present if the chiller is presently configured to log any incoming Adaptive Capacity Control map points. (See the Adaptive Capacity Control Details screen.) Message Clear Access Level Required: SERVICE When certain safety or cycling conditions have been detected and the chiller has been shutdown, the main status display of the chiller will continue to display a message indicating the cause of the shutdown. Using this key, the message can be cleared once the condition has been removed. Warning Reset Access Level Required: OPERATOR Use of this key acknowledges a warning condition and resets the message display associated with it. Soft Shutdown (Software version C.MLM xxx and later and P compressors with C.MLM xxx and later) Access Level Required: Operator This key, available only when the compressor is running, is used to initiate a Soft Shutdown. A Soft Shutdown fully closes the Pre-rotation Vanes prior to shutting down the compressor. This reduces bearing wear by eliminating compressor backspin at shutdown. Pressing this key causes the Vanes to be driven to the fully closed position. While the vanes are closing, Vanes Closing Before Shutdown is displayed on the System Status line. When the Vane Motor Switch (VMS) closes, indicating the vanes have fully closed (or 3.5 minutes have elapsed, whichever occurs first), the Run signal is removed from the compressor motor starter and a System Coastdown is performed. While the vanes are closing, if a Local Stop is initiated with the Compressor Switch or any fault other than Leaving Chilled Liquid Temp Low Temperature, Remote Stop, Multi-Unit Cycling Contacts Open, System Cycling Contacts Open or Control Panel Schedule occur, it will immediately enter System Coastdown. To restart the chiller after an operator initiated Soft shutdown, the Compressor Switch must be placed in the Stop/Reset position () and then the Start position (P). NAVIGATION System Used to provide additional system information. Evaporator A detailed view of all evaporator parameters, including the programmable Leaving Chilled Liquid Setpoints. Condenser A detailed view of all condenser parameters, including control of the liquid level functions. Compressor A detailed view of all the compressor parameters. This includes pre-rotation vane control, Hot Gas Bypass Control, Proximity Probe calibration, and PRV calibration. YORK INTERNATIONAL 21

22 Oil Sump A detailed view of all the oil pump and oil sump parameters. This includes the Variable Speed Oil Pump when installed. It also controls the Seal Lubrication functionality. Motor A detailed view of the motor controller parameters, specific to the controller type presently utilized on the chiller system. This allows programming of the Current Limit and the Pulldown Demand Limit values. For a VSD system, the Adaptive Capacity Control, Harmonic Filter and OptiSave feature information is controlled under this screen. Setpoints This screen provides a single location to program the most common system setpoints. It is also the gateway to many of the general system setup parameters such as Date/Time, Display Units, Scheduling, Printer Setup, etc. History This screen provides access to a snapshot of system data at each of the last 10 shutdown conditions. 22 YORK INTERNATIONAL

23 OPERATIONS SCREEN YK OPTISAVE "OptiSave" Enabled/Disabled Setpoint OVERVIEW This screen allows definition of general parameters having to do with the operation of the chiller. DISPLAY ONLY Chiller Run Time (If compressor application is other than P, applies only to software version C.MLM or later) Displays the amount of time the chiller has been running since the last start signal was received. Value is reset to zero when the chiller enters Coastdown. It remains at zero while shutdown and during System Prelube. PROGRAMMABLE Control Source Access Level Required: OPERATOR Define whether the control of the chiller will be Local, Digital Remote, Analog Remote, Modem Remote or ISN Remote. Number of Starts Access Level Required: ADMIN Displays the number of the starts the chiller has initiated. This may be reprogrammed to a desired value, (generally when this value has been reset due to a Microboard replacement), but should not be done so arbitrarily. Operating Hours Access Level Required: ADMIN Displays the total accumulated run time of the chiller. This may be reprogrammed to a desired value (generally when this value has been reset due to a Microboard replacement), but should not be done so arbitrarily. Hot Gas Control (Enabled/Disabled) Access level required: SERVICE Enables and disables the optional Hot gas Bypass Control feature. Refrigerant Level Control (Enabled / Disabled) Access Level Required: SERVICE Enables and Disables the Refrigerant Level Control Feature. OptiSave VSD Feature (Enabled/Disabled) (Software versions C.MLM xxx or C.OPT.01.09A.xxx and later) Access Level Required: ADMIN Available only if utilizing a Variable Speed Drive motor controller. Enables and Disables the OptiSave VSD feature. If the OptiSave feature is Disabled, the Opti- Save navigation key on the Motor/VSD Screen is not YORK INTERNATIONAL 23

24 displayed and the Total Savings will not be displayed on the Home screen. Edit Phone Numbers (If compressor application is other than P, applies only to software version C.MLM xxx and later) Access Level Required: SERVICE Displays up to two service phone numbers. The Regional service phone number is displayed as the first number. Although the label and number can be changed appropriately, the default for this entry is York Int l North American Toll Free Number The Local service phone number is displayed as the second number. Although blank by default, the appropriate label and number can be entered by a Service Technician. Service Technicians refer to Service Manual M1. NAVIGATION Home Causes an instant return to the Home Screen. Setup Return to the Setup Screen. 24 YORK INTERNATIONAL

25 MOTOR / VARIABLE SPEED DRIVE SCREEN YT & YK OPTISAVE OVERVIEW This screen displays information pertaining to a Variable Speed Drive (VSD). DISPLAY ONLY Motor Run (LED) Indicates whether the digital output from the controls is commanding the motor to RUN. Motor Current % Full Load Amps Displays the motor current as a percentage f the Full Load Amps (FLA) value. Current Limit Setpoint Displays the current limit value in use. This value could come from a 0-20mA, 4-20mA, 0-10VDC or 2-10VDC input in Analog Remote mode, PWM signal in Digital Remote mode, MicroGateway interface in ISN mode or a locally programmed value. Pulldown Demand Time Left Displays the time remaining in the programmed pulldown period if the value is non-zero. Output Voltage Displays the output voltage measured to the motor. "OptiSave" Navigation Key Output Current - Phase A, B, C Displays the phase current measured to the motor. Input Power Displays the total Kilowatts measured by the VSD or Harmonic Filter, if installed. kw Hours Displays the cumulative amount of kilowatts used over time as the VSD motor controller operates. Pre-Rotation Vane Position Displays the pre-rotation vane position as a value between 0 and 100%. Harmonic Filter Data (Harmonic Filter installed only) Supply kva Displays the supply kva measured by the filter. Total Power Factor Displays the relationship between the Input power and the Supply kva. Voltage Total Harmonic Distortion - L1, L2, L3 Displays the Total Harmonic Distortion (THD) for each of the voltage lines as calculated by the filter. Output Frequency Displays the present output frequency to the motor. YORK INTERNATIONAL 25

26 Supply Current Total Demand Distortion - L1, L2, L3 Displays the Total Dynamic Distortion (TDD) for each of the supply current lines as calculated by the filter. PROGRAMMABLE Local Motor Current Limit Access Level Required: OPERATOR Allows the user to specify the maximum allowed motor current (as a percentage of FLA). When the motor current reaches this value, the pre-rotation vanes will not be permitted to open further. If the motor current rises above this value, the pre-rotation vanes will close to reduce the current to this value. Pulldown Demand Limit Access Level Required: OPERATOR Allows the user to specify the current limit value (as a percentage of FLA) to which the chiller will be limited during the specified pulldown limit time. This value will override the Motor Current Limit value during this time period. This function is used to provide energy savings following chiller start-up. Pulldown Demand Time Access Level Required: OPERATOR Allows the user to set a period of time for which the pulldown demand limit will be in effect after the chiller starts. KWH Reset (Software versions: YT - C.MLM xxx and C.OPT.02.04A.xxx or YK - C.MLM xxx or C.OPT.01.08A.xxx and earlier, or versions: YT - C.MLM xxx and C.OPT.02.05A.xxx or YK - C.MLM xxx or C.OPT.01.09A.xxx and later with OptiSave feature Disabled) Access Level Required: SERVICE Allows the user to reset the cumulative kilowatt Hours. (Software versions: YT - C.MLM xxx and C.OPT.02.05A.xxx, or YK - C.MLM xxx and C.OPT.01.09A.xxx and later with OptiSave feature Enabled) The KWH Reset will not be displayed. Reset function is via the OptiSave screen VSD KWh Reset key. Service Technicians refer to YORK Service Manual M1 and M1. Filter Inhibit (Harmonic Filter installed only) Access Level Required: SERVICE Disable the filter logic from activating, although the system will still communicate with the device. Only available when chiller is stopped. NAVIGATION Home Causes an instant return to the Home Screen. VSD Details Moves to the subscreen which provides more information about the Variable Speed Drive. ACC Details Access Level Required: SERVICE Moves to the subscreen which provides more information about the Adaptive Capacity Control. Filter Details (Harmonic Filter installed only) Moves to the subscreen which provides more information about the Harmonic Filter. OptiSave (Software versions: YT - C.MLM xxx and C.OPT.02.05A.xxx, or YK - C.MLM xxx and C.OPT.01.09A.xxx and later with OptiSave feature Enabled) Available only if utilizing a Variable Speed Drive motor controller and the OptiSave feature is enabled. Moves to the subscreen that provides detailed view of the OptiSave Energy Analyzer parameters and provides for the programming of OptiSave Energy Analyzer setpoints. The OptiSave Energy Analyzer Graph and Data screens as well as OptiSave print reports are accessed under this screen. 26 YORK INTERNATIONAL

27 OPTISAVE ENERGY ANALYZER SCREEN YT & YK Software versions: YT - C.MLM xxx and C.OPT.02.05A.xxx, or YK - C.MLM xxx and C.OPT.01.09A.xxx and later. OVERVIEW This screen displays information pertaining to the OptiSave Energy Analyzer VSD feature. The Opti- Save Energy Analyzer feature determines the amount of energy saved in applying a Variable Speed Drive versus a Constant Speed Drive on a centrifugal chiller. DISPLAY ONLY Condenser Liquid Temperature - Return Displays the temperature of the liquid as it enters the condenser. Input Power Displays the total Kilowatts (kw) measured by the VSD or Harmonic Filter, if installed. Constant Speed Meter Displays the cumulative amount of calculated kilowatts over time (kwh), that would have been used by a Constant Speed motor controller. Variable Speed Meter Displays the cumulative amount of kilowatts used over time (kwh) as the VSD motor controller operates. Last Full Calendar Month Minimum Return Condenser Liquid Temperature Displays the value of the Monthly Minimum Return Condenser Liquid Temperature for the month prior to the present month. Last Full Calendar Month Savings Displays the amount of the monthly saved energy (kwh) for the prior month. Total Energy Savings Displays the cumulative calculated amount of kwh saved in using a Variable Speed Drive vs. a Constant Speed Drive. Based on an energy cost of Per kwh, Displays the Price Per kwh setpoint value used to compute the Total Savings in USD. the total savings would be USD. Displays the calculated amount in USD of the Total Energy Savings (kwh) multiplied by the Price Per kwh. YORK INTERNATIONAL 27

28 PROGRAMMABLE Price Per kwh Access Level Required: Service Allows user to specify the Price Per kwh value in USD (0.00) used to compute the Total Savings in USD. If the Price Per kwh is zero (0), the total USD savings will not be calculated or displayed. Home Screen Display Access Level Required: Service Allows user to select the Total Savings mode displayed on the Home Screen as either the Total Energy Saved (kwh) or the Total Savings (USD). If the Price Per kwh is zero, the Total Energy Saved (kwh) is displayed, regardless of the mode selected, and the Total Savings in USD will not be calculated. CSD Design kw Access Level Required: ADMIN Allows user to specify the VSD Design kw. If the CSD Design kw is 0 kw, the OptiSave feature will not function. VSD Design kw Access Level Required: ADMIN Allows user to specify the VSD Design kw. If the VSD Design kw is 0 kw, the OptiSave feature will not function. Print Access Level Required: Operator Keypress generates a hard-copy report that provides a snapshot of the OptiSave Energy Analyzer data at the time the key is pressed. The OptiSave Energy Analyzer report is a manual print report that is not available for Data Logging setup as an automatic printing report. NAVIGATION Home Causes an instant return to the Home Screen. Motor A detailed view of the motor controller parameters, specific to the controller type presently utilized on the chiller system. This allows programming of the Current Limit and the Pulldown Demand Limit values. For a VSD system, the Adaptive Capacity Control and Harmonic Filter information is controlled under this screen. Graph (OptiSave) Moves to the subscreen that provides a bar graph display of the VSD Monthly Total Energy Used verus the CSD Monthly Total Energy Used for the past 12 months. Data (OptiSave) Access Level Required: ADMIN Moves to the subscreen that displays and allows for the modification of the VSD kwh Meter, the CSD kwh Meter, the Total Energy Savings, and the Monthly Total Saved Energy (x12 months) values. 428 YORK INTERNATIONAL

29 OPTISAVE ENERGY ANALYZER GRAPH SCREEN YT & YK Software versions: YT - C.MLM xxx and C.OPT.02.05A.xxx, or YK - C.MLM xxx and C.OPT.01.09A.xxx and later OVERVIEW This OptiSave Energy Analyzer subscreen displays a bar graph representation of the VSD (kwh) Monthly Total Energy Used verus the CSD (kwh) Monthly Total Energy Used for the past 12 months. The X-Axis labels are the past 12 operating months. The Y-Axis kwh labels are automatically scaled to the highest of the monthly values. DISPLAY ONLY Constant Speed Meter Displays a bar graph representation of the calculated value of kwh that would be consumed if using a Constant Speed Drive, for the past 12 months. Variable Speed Meter Displays a bar graph representation of the actual value of kwh being consumed by the Variable Speed Drive, for the past 12 months. NAVIGATION Home Causes an instant return to the Home Screen. OptiSave Returns to the OptiSave screen which provides detailed data pertaining to the OptiSave Energy Analyzer VSD feature. YORK INTERNATIONAL 529

30 OPTISAVE ENERGY ANALYZER DATA SCREEN YT & YK Software versions: YT - C.MLM xxx and C.OPT.02.05A.xxx, or YK - C.MLM xxx and C.OPT.01.09A.xxx and later OVERVIEW Access Level Required: ADMIN This OptiSave Energy Analyzer subscreen displays and provides access to modify the VSD kwh Meter, the CSD kwh Meter, the Total Energy Savings, and the Monthly Total Saved Energy (x12 months) values used by the OptiSave energy Analyzer software feature. DISPLAY ONLY Constant Speed Meter Displays the cumulative amount of calculated kilowatts over time (kwh), that would have been used by a Constant Speed motor controller. Variable Speed Meter Displays the cumulative amount of kilowatts used over time (kwh) as the VSD motor controller operates. Total Energy Savings Displays the cumulative calculated amount of kwh saved in using a Variable Speed Drive vs. a Constant Speed Drive. PROGRAMMABLE Print Access Level Required: ADMIN Keypress generates a hard-copy report of the Opti- Save Energy Analyzer Setpoint data at the time the key is pressed. This report prints the following setpoint data: Report Title Chiller ID Copyright message Time/Date Software Version CSD Design kw VSD Design kw Price Per kwh Home Screen Display Mode (Energy/USD) CSD kwh Meter VSD kwh Meter Total Saved Energy 12 Monthly Total Energy Savings Meters 430 YORK INTERNATIONAL

YK CENTRIFUGAL LIQUID CHILLER

YK CENTRIFUGAL LIQUID CHILLER YK CENTRIFUGAL LIQUID CHILLER OptiView Control Panel OPERATION INSTRUCTION Effective from 11/00 GB i 160-54-OI-GB0 Contents 1 HOME SCREEN 4 2 SYSTEM SCREEN 5 3 EVAPORATOR SCREEN 6 4 CONDENSER SCREEN 8

More information

OPTIVIEW CONTROL CENTER MODEL YS (STYLE E)

OPTIVIEW CONTROL CENTER MODEL YS (STYLE E) MODEL YS (STYLE E) SCREW LIQUID CHILLERS RENEWAL PARTS Supersedes: 160.80-RP3 (105) Form 160.80-RP3 (307) OPTIVIEW CONTROL CENTER 371-02459-101 371-02579-101 371-02578-101 371-02459-102 371-02579-102 371-02578-102

More information

GRAPHIC CONTROL CENTER , , , , , , 102

GRAPHIC CONTROL CENTER , , , , , , 102 MODEL YR SCREW LIQUID CHILLERS RENEWAL PARTS Supercedes: 160.81-RP3 (307) Form 160.81-RP3 (507) GRAPHIC CONTROL CENTER 371-02772-101, 102 371-02773-101, 102 371-02774-101, 102 371-04175-101, 102 371-04176-101,

More information

where we are, where we could be, how we can get there. 12/14/2011

where we are, where we could be, how we can get there. 12/14/2011 Central Plant Optimization ASHRAE National Capitol Chapter - PES Wednesday, Nov 7, 2011 Dave Klee, LEED AP Director, Optimized Building Solutions Johnson Controls, Inc. 1 1 J o http://www.johnsoncontrols.com/cpo

More information

User Guide. FreeCool : Free Cooling unit V1.1 ENGY-SVU001A-GB

User Guide. FreeCool : Free Cooling unit V1.1 ENGY-SVU001A-GB User Guide FreeCool : Free Cooling unit V1.1 ENGY-SVU001A-GB Table of Contents Introduction...3 General features...4 User interface...5 Top display area... 5 Bottom display area... 5 Main display area...

More information

MICROCOMPUTER CONTROL CENTER PART NO. FOR

MICROCOMPUTER CONTROL CENTER PART NO. FOR RENEWAL PARTS CENTRIFUGAL LIQUID CHILLERS Supersedes: See Back Cover Form 160.48-RP3 (1197) MICROCOMPUTER CONTROL CENTER PART NO. FOR 371-01200-002 ELECTROMECHANICAL STARTER, SOLID STATE STARTER AND TURBO-MODULATOR

More information

MICROCOMPUTER CONTROL CENTER

MICROCOMPUTER CONTROL CENTER OPERATION ROTARY SCREW LIQUID CHILLERS Supersedes: See Back Cover Form 160.47-O1.1 (197) MICROCOMPUTER CONTROL CENTER PART NO. 371-01112-001 or 371-01200-003 FOR MODEL YS BA BA S0 THRU YS FC FB S5 (STYLE

More information

UC DAVIS THERMAL ENERGY STORAGE (TES) TANK OPTIMIZATION INVESTIGATION MATTHEW KALLERUD, DANNY NIP, MIANFENG ZHANG TTP289A JUNE 2012

UC DAVIS THERMAL ENERGY STORAGE (TES) TANK OPTIMIZATION INVESTIGATION MATTHEW KALLERUD, DANNY NIP, MIANFENG ZHANG TTP289A JUNE 2012 UC DAVIS THERMAL ENERGY STORAGE (TES) TANK OPTIMIZATION INVESTIGATION MATTHEW KALLERUD, DANNY NIP, MIANFENG ZHANG TTP289A 004 11 JUNE 2012 TABLE OF CONTENTS Abstract...3 Introduction...3 Methodology...4

More information

MODELS VSD 270, 292, 351, 385, 419, 424, 503, 608, 658, AND 704 MODELS LVD 270, 292, 351, 385, 419, 424, 503, 608, 658, 704, AND 900

MODELS VSD 270, 292, 351, 385, 419, 424, 503, 608, 658, AND 704 MODELS LVD 270, 292, 351, 385, 419, 424, 503, 608, 658, 704, AND 900 LIQUID COOLED OPTISPEED COMPRESSOR SPEED DRIVE OPERATION MANUAL Supersedes: 160.00-O4 (415) Form 160.00-O4 (1217) MODELS VSD 270, 292, 351, 385, 419, 424, 503, 608, 658, AND 704 MODELS LVD 270, 292, 351,

More information

M&M Refrigeration, Inc. Computer Control System. Screw Compressor Control Sullair Retro Fit Panel

M&M Refrigeration, Inc. Computer Control System. Screw Compressor Control Sullair Retro Fit Panel & M&M Refrigeration, Inc. Computer Control System Screw Compressor Control Sullair Retro Fit Panel Standard Screw Compressor - Sullair Copyright protection claimed includes all forms and matters now and

More information

32MP Gateway. Overview and Configuration Manual

32MP Gateway. Overview and Configuration Manual 32MP Gateway Overview and Configuration Manual 32MP Gateway Overview and Configuration Manual This document is the property of Carrier Corporation and is delivered on the express condition that it is not

More information

Supplement to PM WSC/WDC-1 MicroTech II for Centrifugal Compressor Water Chillers

Supplement to PM WSC/WDC-1 MicroTech II for Centrifugal Compressor Water Chillers Engineering Data SED: 8012 Group: Centrifugal Chiller Date: March 2002 Supercedes: New Supplement to PM WSC/WDC-1 MicroTech II for Centrifugal Compressor Water Chillers Model WSC/WDC 2002 McQuay International

More information

PROGRAMMING GUIDE

PROGRAMMING GUIDE www.altroniccontrols.com PROGRAMMING GUIDE DEVIATION FROM THESE INSTRUCTIONS MAY LEAD TO IMPROPER ENGINE/MACHINE OPERATION WHICH COULD WARNING: CAUSE PERSONAL INJURY TO OPERATORS OR OTHER NEARBY PERSONNEL.

More information

SiteView Energy Meter User Guide

SiteView Energy Meter User Guide SiteView Energy Meter User Guide Acuity Brands One Lithonia Way Conyers, GA 30012 Phone: 800.535.2465 www.acuitycontrols.com 2017 Acuity Brands Lighting, Inc. All rights reserved. TABLE OF CONTENTS CHAPTER

More information

4/8/ nd Annual OTCO WW Workshop W/WW Product Overview ACQ550. ABB Slide 1

4/8/ nd Annual OTCO WW Workshop W/WW Product Overview ACQ550. ABB Slide 1 4/8/2015 52 nd Annual OTCO WW Workshop W/WW Product Overview ACQ550 Slide 1 Drive Basics Why Use Adjustable Speed Drives? Reduced Energy Consumption Improved Process Control / Efficiency Increased Product

More information

ADDENDUM WCFX. Vision 2020i Touch Screen Controller. - a1 - Vision 2020i Controller

ADDENDUM WCFX. Vision 2020i Touch Screen Controller. - a1 - Vision 2020i Controller WCFX Vision 2020i Touch Screen Controller - a1 - 1.4 VISION 2020i CONTROLLER AND TERMINAL 1.4.1.1 The fourteen touch keys: Key Description MAIN Display the main screen Vision 2020i controller is equipped

More information

Series 3000 User Manual and Product Features

Series 3000 User Manual and Product Features Series 3000 User Manual and Product Features PN: OXA3501-890000 Revision 1.0 Technical Specifications 1.1 Model Number Description 1. Meter Series S3 Series 3000 meter Figure 1: Series 3000 model number

More information

Operating Instructions

Operating Instructions Beckman Instructions 511290-AA Φ ph/temperature/mv/ise Meters Operating Instructions Beckman Instruments, Inc. 4300 N. Harbor Blvd., Fullerton, CA 93835 Copyright 1998 Beckman Instruments, Inc. Printed

More information

MicroMVL Release History. Note: Changes in black mean new features or capabilities and red changes mean corrections from previous versions.

MicroMVL Release History. Note: Changes in black mean new features or capabilities and red changes mean corrections from previous versions. MicroMVL Release History Note: Changes in black mean new features or capabilities and red changes mean corrections from previous versions. Version Release Date Changes 2.23 18-May-2018 Fixed Audit Trail

More information

INSTRUCTION MANUAL IM253 R0. AquaStart COMBINATION SOFT STARTERS START-UP MANUAL

INSTRUCTION MANUAL IM253 R0. AquaStart COMBINATION SOFT STARTERS START-UP MANUAL INSTRUCTION MANUAL IM253 R0 AquaStart COMBINATION SOFT STARTERS START-UP MANUAL INDEX Power Connections...3 Basic Wiring...4 Start-Up By Voltage Ramp...5 Local / Remote Modes...6 Control and Signal Connections...6

More information

Quantum HD Release Notes

Quantum HD Release Notes Quantum HD Release Notes OS Version 10.17 Released 7-14-2014 To upgrade to OS version 10.17 directly the current OS version must be 10.13 through 10.16. To check the current OS version on the Quantum HD

More information

Instruction Manual. ROYTRONIC EXCEL Series AD9 Programming Guide Electronic Metering Pumps

Instruction Manual. ROYTRONIC EXCEL Series AD9 Programming Guide Electronic Metering Pumps Instruction Manual ROYTRONIC EXCEL Series AD9 Programming Guide Electronic Metering Pumps For file reference, please record the following data: Model No: Serial No: Installation Date: Installation Location:

More information

BACVIEW MANUAL Software Version 3.06 INSTALLATION AND OPERATION MANUAL

BACVIEW MANUAL Software Version 3.06 INSTALLATION AND OPERATION MANUAL BACVIEW MANUAL Software Version 3.06 INSTALLATION AND OPERATION MANUAL 641-K31 1 BACVIEW INSTALLATION AND OPERATION IMPORTANT: This manual is for use with controller ZONE I/O 560 FHP part number 641-224

More information

The Future. Today. YZ MAGNETIC BEARING CENTRIFUGAL CHILLER

The Future. Today. YZ MAGNETIC BEARING CENTRIFUGAL CHILLER The Future. Today. YZ MAGNETIC BEARING CENTRIFUGAL CHILLER YZ MAGNETIC BEARING CENTRIFUGAL CHILLER YORK YZ Magnetic Bearing Centrifugal Chiller The YORK YZ Magnetic Bearing Centrifugal Chiller is a revolutionary

More information

NFX MARKET DATA FEED INTERFACE SPECIFICATIONS. NFX Market Data Feed

NFX MARKET DATA FEED INTERFACE SPECIFICATIONS. NFX Market Data Feed NFX Market Data Feed Table of Contents 1 INTRODUCTION... 3 1.1 PURPOSE... 3 1.2 ARCHITECTURE... 3 2 SESSION CHARACTERISTICS... 4 2.1 REAL-TIME PRODUCTION DATA... 4 2.2 PRE-LAUNCH TEST DATA... 4 2.3 TRANSMISSION

More information

CONTROLS. Quantum HD. Heavy Duty Performance In High Definition

CONTROLS. Quantum HD. Heavy Duty Performance In High Definition CONTROLS Quantum HD Heavy Duty Performance In High Definition CONTROLS Quantum HD Industrial Refrigeration Controller Quantum HD with Unity Architecture Quantum HD control panels make equipment management

More information

MODELS: STEAM FIRED YPC-ST-14SC & YPC-ST-16SL Thru YPC-ST-19S

MODELS: STEAM FIRED YPC-ST-14SC & YPC-ST-16SL Thru YPC-ST-19S Supersedes: 155.19-W1 (407) Form: 155.19-W1 (812) TWO-STAGE ABSORPTION CHILLERS WIRING DIAGRAMS CONTRACTOR ORDER NO. JCI CONTRACT NO. JCI ORDER NO. PURCHASER JOB NAME LOCATION ENGINEER REFERENCE DATE APPROVAL

More information

PoolPak MPK with CommandPak Control System CPCS BACnet /IP User s Guide DOCUMENT #: SVW07-MPKBACNIP

PoolPak MPK with CommandPak Control System CPCS BACnet /IP User s Guide DOCUMENT #: SVW07-MPKBACNIP PoolPak MPK with CommandPak Control System CPCS BACnet /IP User s Guide DOCUMENT #: SVW07-MPKBACNIP-20171020 UPDATED: OCTOBER 2017 INTRODUCTION PoolPak dehumidifiers equipped with an CommandPak Control

More information

Models beginning with 2M, 2L or 2X. Product Description. Technical Specifications. Installation Instructions. Series 2000 Multiple Meter Units (MMUs)

Models beginning with 2M, 2L or 2X. Product Description. Technical Specifications. Installation Instructions. Series 2000 Multiple Meter Units (MMUs) Models beginning with 2M, 2L or 2X Series 2000 Multiple Meter Units (MMUs) Product Description Technical Specifications Installation Instructions February 28 th, 2013 List of Figures...2 List of Tables...2

More information

CommandCenter Operator Panel

CommandCenter Operator Panel CommandCenter Operator Panel Introduction This document describes the different features of the Operator Panel (local or remote) that is used with the Seresco units. Startup Screens When the unit start

More information

OM Operation and Maintenance Manual. Intelligent Equipment for Daikin Applied Trailblazer Air-cooled Scroll Chiller. Models: AGZ-D and AGZ-E

OM Operation and Maintenance Manual. Intelligent Equipment for Daikin Applied Trailblazer Air-cooled Scroll Chiller. Models: AGZ-D and AGZ-E Operation and Maintenance Manual Intelligent Equipment for Daikin Applied Trailblazer Air-cooled Scroll Chiller OM 1241 Group: Controls Part Number: 910166134 Date: June 2015 Models: AGZ-D and AGZ-E Table

More information

What is the Carrier ChillerVu series counterflow application?

What is the Carrier ChillerVu series counterflow application? Carrier ChillerVu 23XRV Series Counterflow Application Guide CARRIER CORPORATION 2017 A member of the United Technologies Corporation family Stock symbol UTX Catalog No. 11-808-578-01 4/5/2017 Verify that

More information

Quick Start Guide. Variable Speed Drive. Part Number: Issue: 3

Quick Start Guide. Variable Speed Drive. Part Number: Issue: 3 EVC Series Quick Start Guide English Issue 3.book Page 1 Friday, March 11, 2016 1:38 PM Quick Start Guide Variable Speed Drive Part Number: 0478-0335-03 Issue: 3 Original Instructions For the purposes

More information

Service Information. File In/With: N/A. Equipment Affected: YCAV & YCIV Chillers

Service Information. File In/With: N/A. Equipment Affected: YCAV & YCIV Chillers Service Information File In/With: N/A (Supersedes SI0144 [11-06]) Equipment Affected: YCAV & YCIV Chillers SI0144 Rev 2 9-08 Ordering, Installation & Activation of YCAV & YCIV Optimized IPLV Aftermarket

More information

Service Bulletin SB685. Date: 8/18/2017 TriPac EVOLUTION Communications Update Bulletin Location: TSA Info Central\Service Bulletins

Service Bulletin SB685. Date: 8/18/2017 TriPac EVOLUTION Communications Update Bulletin Location: TSA Info Central\Service Bulletins Service Bulletin SB685 Date: 8/18/2017 Subject: TriPac EVOLUTION Communications Update Bulletin Location: TSA Info Central\Service Bulletins Units: All TriPac EVOLUTION Summary: This bulletin updates and

More information

pco 3 Controller User Manual ASPX Digital Scroll, Air Packaged Chiller For Version MCDSV_A02

pco 3 Controller User Manual ASPX Digital Scroll, Air Packaged Chiller For Version MCDSV_A02 pco 3 Controller User Manual ASPX Digital Scroll, Air Packaged Chiller For Version MCDSV_A02 pco 3 Controller User Manual Introduction The Airstack Chiller is a modular air-cooled chiller composed of

More information

Baltimore Aircoil Company

Baltimore Aircoil Company Baltimore Aircoil Company VFD Startup Guide TABLE OF CONTENTS: A. Verifying Power and Control Wiring...1 B. Setting the VFD Parameters...2 C. Reentering Startup Wizard After Initial Setup...5 D. Starting

More information

Trane Engineering News Chiller Plant Case Study: Variable-Primary Flow Series Chillers with Free Cooling

Trane Engineering News Chiller Plant Case Study: Variable-Primary Flow Series Chillers with Free Cooling Trane Engineering News Chiller Plant Case Study: Variable-Primary Flow Series Chillers with Free Cooling CHILLER PLANT CONTROLS The challenges of producing chilled water are not the same as those a decade

More information

Stream Depletion Factor Model SDF View

Stream Depletion Factor Model SDF View Stream Depletion Factor Model SDF View User Manual - Version 1.2 Developed for the South Platte Advisory Committee by the Integrated Decision Support Group (IDS) at Colorado State University User Manual

More information

DEKKER KNOWLEDGE DATABASE KNOWLEDGE IS POWER

DEKKER KNOWLEDGE DATABASE KNOWLEDGE IS POWER DEKKER KNOWLEDGE DATABASE For Use with DEKKER Vacuum Systems Equipped with the DEKKER Controller Each Vmax system is tested and checked at the factory prior to shipment to ensure trouble-free operation.

More information

Manual. NanoTron Dual Timer. Installation Maintenance Repair Manual

Manual. NanoTron Dual Timer. Installation Maintenance Repair Manual Manual NanoTron Dual Timer Installation Maintenance Repair Manual Advantage Controls P.O. Box 1472 Muskogee, OK 74402 Phone: 800-743-7431 Fax: 888-686-6212 www.advantagecontrols.com email: support@advantagecontrols.com

More information

Upgrade Instructions. View Manager 96 v Software Upgrade. The system displays the following prompt:

Upgrade Instructions. View Manager 96 v Software Upgrade. The system displays the following prompt: WORLD LEADER IN ELECTRONIC SECURITY Upgrade Instructions View Manager 96 v. 5.0 1 Software Upgrade This software permits you to upgrade your VM96 version 3.x or 4.x system to the latest version of VM96

More information

NODE CONTROLLER PROGRAMMING GUIDE 2/2013 NODE CONTROLLER INTRODUCTION

NODE CONTROLLER PROGRAMMING GUIDE 2/2013 NODE CONTROLLER INTRODUCTION NODE CONTROLLER PROGRAMMING GUIDE 2/2013 NODE CONTROLLER INTRODUCTION THE PROGRAM MENU BUTTON ALLOWS YOU TO NAVIGATE BETWEEN MENUS. PRESS THE PROGRAM MENU BUTTON TO FIRST WAKE UP THE UNIT. DURING A SHORT

More information

Next Generation DCP Optimization using MV VSDs

Next Generation DCP Optimization using MV VSDs Next Generation DCP Optimization using MV VSDs Vivek Apte Regional Product Director Johnson Controls - Middle East Cell : +971506243059 IDEA 2016- Dubai 1 Central Plant Optimization Energy and operating

More information

FRICK QUANTUM HD UNITY SYSTEM CONTROLLER

FRICK QUANTUM HD UNITY SYSTEM CONTROLLER Form 090.670-O (AUG 2015) OPERATION File: SERVICE MANUAL - Section 90 Replaces: NOTHING Dist: 3, 3a, 3b, 3c OPERATION FRICK QUANTUM HD UNITY SYSTEM CONTROLLER ENGINE ROOM CONDENSER VESSEL EVAPORATOR Version

More information

TimeCard Manager Basic

TimeCard Manager Basic TimeCard Manager Basic Program Guide Installation and Setup Basics Continued Install Software 1 Card Management Software Setup View Employee Time Cards 24 Host/Server Security & Settings 2 Print Card Data

More information

Large Tonnage Chillers. Kingsley Hu Technical Support Engineer

Large Tonnage Chillers. Kingsley Hu Technical Support Engineer Large Tonnage Chillers Kingsley Hu Technical Support Engineer Chongqing Plant Chiller Products Reference Projects Manufacturing Facility Major Milestones Global R&D Talent Production Line introduction

More information

Energy Logger. User's Guide. Model EM Washington Street Melrose, MA Phone Toll Free

Energy Logger. User's Guide. Model EM Washington Street Melrose, MA Phone Toll Free User's Guide 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Energy Logger Model EM100 Introduction Congratulations on your purchase

More information

All King County Summary Report

All King County Summary Report September, 2016 MTD MARKET UPDATE Data Current Through: September, 2016 18,000 16,000 14,000 12,000 10,000 8,000 6,000 4,000 2,000 0 Active, Pending, & Months Supply of Inventory 15,438 14,537 6.6 6.7

More information

MODEL YT (STYLE J) R123 COOLING ONLY WITH OPTIVIEW CONTROL CENTER FOR ELECTRO-MECHANICAL STARTER, SOLID STATE STARTER & VARIABLE SPEED DRIVE

MODEL YT (STYLE J) R123 COOLING ONLY WITH OPTIVIEW CONTROL CENTER FOR ELECTRO-MECHANICAL STARTER, SOLID STATE STARTER & VARIABLE SPEED DRIVE MILLENNIUM CENTRIFUGAL LIQUID CHILLERS OPERATING & MAINTENANCE Supersedes: 160.55-O1 (402) Form 160.55-O1 (604) MODEL YT (STYLE J) R123 COOLING ONLY WITH OPTIVIEW CONTROL CENTER FOR ELECTRO-MECHANICAL

More information

Meter Intelligence: Turning Your Meter Data Into Energy Management Information. Quick Guide for Users

Meter Intelligence: Turning Your Meter Data Into Energy Management Information. Quick Guide for Users Meter Intelligence: Turning Your Meter Data Into Energy Management Information Quick Guide for Users June 2007 Meter Intelligence Introduction Meter Intelligence is a web-based interval meter data analysis

More information

VERIS H8035 and H8036

VERIS H8035 and H8036 VERIS H8035 and H8036 MODBUS IMPLEMENTATION SPECIFICATION OVERVIEW This document describes the implementation of Modbus protocol used in the Veris H8035 and H8036 power meters. It is intended to assist

More information

CONSTELLATION Field Controller Operation Manual

CONSTELLATION Field Controller Operation Manual FIELD CONTROL SYSTEMS CONSTELLATION OPERATION MANUAL CONSTELLATION Field Controller Operation Manual Firmware Version 6.00 Document Title CONSTELLATION FIELD CONTROLLER OPERATION MANUAL FIRMWARE VERSION

More information

BACnet MS/TP Interface User s Guide

BACnet MS/TP Interface User s Guide PoolPak MPK with CommandPak Control System CPCS BACnet MS/TP Interface User s Guide DOCUMENT #: SVW07-BACNET-MSTP-20171020 UPDATED: OCTOBER 2017 INTRODUCTION PoolPak dehumidifiers equipped with an CommandPak

More information

Markets Gateway Roadmap

Markets Gateway Roadmap Markets Gateway Roadmap As of April 17, 2018 www.pjm.com Background Markets Gateway allows users to submit information and obtain data needed to conduct business in the Day-Ahead, Regulation and Synchronized

More information

Machine and Contract Setup

Machine and Contract Setup Machine and Contract Setup Updated July 2016 Contents About Machine and Contract Setup...3 Machine Detail...3 Machine Depreciation...4 Creating Database Records...5 Printing the Depreciation Report...5

More information

Seattle (NWMLS Areas: 140, 380, 385, 390, 700, 701, 705, 710) Summary

Seattle (NWMLS Areas: 140, 380, 385, 390, 700, 701, 705, 710) Summary September, 2016 MTD MARKET UPDATE Data Current Through: September, 2016 (NWMLS Areas: 140, 380, 385, 390,, 701, 705, 710) Summary Active, Pending, & Months Supply of Inventory 5,000 4,500 4,000 3,500 4,091

More information

19XR CONTROLS UPGRADE with Optional VFD control

19XR CONTROLS UPGRADE with Optional VFD control MCS Total Solutions for all your HVAC/R Control Needs 19XR CONTROLS UPGRADE with Optional VFD control This brochure describes a standard upgrade package for the 19XR CHILLER. Each Control upgrade installation

More information

Smart-Metering Energy Management Tenant Resource. For your reference we have enclosed the CARMA Smart Metering Software Instruction Manual.

Smart-Metering Energy Management Tenant Resource. For your reference we have enclosed the CARMA Smart Metering Software Instruction Manual. To: Toronto College Park Tenants Re: Smart-Metering Energy Management Tenant Resource GWL Realty Advisors would like to take this opportunity to remind tenants with Carma meters of the online CARMA Smart

More information

GRASSO SYSTEM CONTROL

GRASSO SYSTEM CONTROL Control device for Packages and Chillers with screw compressors Product information 09.2002/ 2 638630_pi gsc gbr.doc Copyright GmbH Refrigeration Technology The contents of this documentation and the enclosed

More information

Seattle (NWMLS Areas: 140, 380, 385, 390, 700, 701, 705, 710) Summary

Seattle (NWMLS Areas: 140, 380, 385, 390, 700, 701, 705, 710) Summary October, 2016 MTD MARKET UPDATE Data Current Through: October, 2016 (NWMLS Areas: 140, 380, 385, 390,, 701, 705, 710) Summary Active, Pending, & Months Supply of Inventory 4,500 4,000 3,500 4,197 4,128

More information

MiG2 CONTROLLERS. 2 & 4 Stage General Purpose Controllers, with Air-conditioning Facilities

MiG2 CONTROLLERS. 2 & 4 Stage General Purpose Controllers, with Air-conditioning Facilities MiG2 CONTROLLERS 2 & 4 Stage General Purpose Controllers, with Air-conditioning Facilities The MiG2 controllers incorporate: 2 Inputs (Configurable as Resistive, 0 10V, 0 20mA or 4 20mA) 2 or 4 Relay Outputs

More information

Message Networking 5.2 Maintenance print guide

Message Networking 5.2 Maintenance print guide Page 1 of 304 Maintenance print guide This print guide is a collection of system topics provided in an easy-to-print format for your convenience. Note: The links shown in this document do not work online,

More information

Seattle (NWMLS Areas: 140, 380, 385, 390, 700, 701, 705, 710) Summary

Seattle (NWMLS Areas: 140, 380, 385, 390, 700, 701, 705, 710) Summary November, 2016 MTD MARKET UPDATE Data Current Through: November, 2016 (NWMLS Areas: 140, 380, 385, 390,, 701, 705, 710) Summary 4,000 3,500 3,000 2,500 2,000 1,500 1,000 500 0 Active, Pending, & Months

More information

User Guide for the WegenerNet Data Portal

User Guide for the WegenerNet Data Portal User Guide for the WegenerNet Data Portal (v9/18feb2010) The WegenerNet Data Portal provides access to measurement data from the climate stations as well as detailed information about the project. Quality-checked

More information

Complete Thermal-Grid User Guide

Complete Thermal-Grid User Guide Complete Thermal-Grid User Guide For use by Building/Homeowners, Portfolio Managers & Technicians Table of Contents 1. Login... 2 1.1 PROFILE... 2 1.2 Manage Team (add or modify users (team members) access)...

More information

Instruction Manual. Save These Instructions. Centrifugal Compressor Control System. Model X e -145F

Instruction Manual. Save These Instructions. Centrifugal Compressor Control System. Model X e -145F 23692965 Revision C October 2010 Centrifugal Compressor Control System Model X e -145F Instruction Manual EN ES FR IT DE PT CS PL TU ZH Instruction Manual Manual de instrucciones Manuel d instruction Manuale

More information

FLOWgate500. Software Manual. Software Manual FLOWgate500 Release 2.2. Revision number: V2.2. Manufacturer: SICK AG. Erwin-Sick-Str.

FLOWgate500. Software Manual. Software Manual FLOWgate500 Release 2.2. Revision number: V2.2. Manufacturer: SICK AG. Erwin-Sick-Str. FLOWgate500 Software Manual Software Manual FLOWgate500 Release 2.2 Revision number: V2.2 Manufacturer: SICK AG Erwin-Sick-Str.1 D-79183 Waldkirch Germany Place of manufacture: SICK Engineering GmbH Bergener

More information

MYRIAD RTU REMOTE TELEMETRY UNITS INSTRUCTION MANUAL

MYRIAD RTU REMOTE TELEMETRY UNITS INSTRUCTION MANUAL MYRIAD RTU REMOTE TELEMETRY UNITS INSTRUCTION MANUAL VISIT OUR WEBSITE SIGMACONTROLS.COM MYR RTU MANUAL 061314 2 TABLE OF CONTENTS INTRODUCTION 3 Ordering Information Specifications Features WIRING 8 Dwg

More information

Sidewinder Pumps Inc. AC Timer/Controller

Sidewinder Pumps Inc. AC Timer/Controller Sidewinder Pumps Inc. AC Timer/Controller Page 1 of 12 Rev 032417 Table of Contents 1. Warnings-------------------------------------------------------------------------------------------------- 3 1.1.

More information

AMERICAN CHANGER CORP.

AMERICAN CHANGER CORP. AMERICAN CHANGER CORP. 1400 NW 65 TH PLACE Sales: (800) 741-9840 FORT LAUDERDALE, FL 33309 Parts & Service: (888) 741-9840 www.americanchanger.com Fax: (954) 917-5204 AC7076 & AC7076.1 AUDIT PRINTER USER

More information

Silicon Valley Power Data Center Program Rebate Application

Silicon Valley Power Data Center Program Rebate Application Contact Information Tax Status (check one) Sole Proprietor Contact Name Phone Corporation Partnership Company Email address Government Not-For-Profit Customer/Facility Information Company Name SVP Account

More information

Sidewinder Pumps Inc. AC C1D2 Timer/Controller

Sidewinder Pumps Inc. AC C1D2 Timer/Controller Sidewinder Pumps Inc. AC C1D2 Timer/Controller Page 1 of 14 Rev 4/26/17 Table of Contents 1. Warnings --------------------------------------------------------------------------------------------------

More information

CHAPTER/REGIONAL TECHNOLOGY AWARD - SHORT FORM

CHAPTER/REGIONAL TECHNOLOGY AWARD - SHORT FORM CHAPTER/REGIONAL TECHNOLOGY AWARD - SHORT FORM 1. Category (Check one and indicate New or Existing, if applicable) Commercial Buildings New or Existing Institutional Buildings: Educational Facilities New

More information

FREQUENTLY ASKED QUESTIONS

FREQUENTLY ASKED QUESTIONS DISTRICT 7030 WEBSITE FREQUENTLY ASKED QUESTIONS NB: THIS WILL BE REGULARLY UPDATED FOR YOUR INFORMATION. 1. This website works better with the following browsers: Internet Explorer (IE) and Google Chrome.

More information

OPERATION & SERVICE MANUAL VC1100 Series MDB-120 Controller Software 120 Volts, 60 HZ 230 Volts, 50 HZ

OPERATION & SERVICE MANUAL VC1100 Series MDB-120 Controller Software 120 Volts, 60 HZ 230 Volts, 50 HZ OPERATION & SERVICE MANUAL VC1100 Series MDB-120 Controller 67196-1 Software 120 Volts, 60 HZ 230 Volts, 50 HZ Seaga Manufacturing, Inc. 700 Seaga Drive, Freeport IL USA Phone: 815-297-9500 - Fax: 815-297-1700

More information

EMU-2. Energy Monitoring Unit. User Manual

EMU-2. Energy Monitoring Unit. User Manual Energy Monitoring Unit Version 1.04 Dec 2012 Copyright 2012 by RAINFOREST AUTOMATION, INC ( RFA ). All rights reserved. No part of this manual may be reproduced or transmitted in any from without the expressed,

More information

MENU BUTTON FULL OPERATORS MANUAL FOR POWER-MATE LITE QUICK START MANUAL BEGINS ON PAGE 5 OVERVIEW GENERAL PRECAUTIONS BEFORE USING THE PML

MENU BUTTON FULL OPERATORS MANUAL FOR POWER-MATE LITE QUICK START MANUAL BEGINS ON PAGE 5 OVERVIEW GENERAL PRECAUTIONS BEFORE USING THE PML FULL OPERATORS MANUAL FOR POWER-MATE LITE QUICK START MANUAL BEGINS ON PAGE 5 OVERVIEW Congratulations on your purchase of the new Power-Mate-Lite (PML). PML is easy to use, accurate and can help you to

More information

DESIGO PX PXM20 / PXM20-E operator unit User's guide. Version 2.2 and later. Building Technologies

DESIGO PX PXM20 / PXM20-E operator unit User's guide. Version 2.2 and later. Building Technologies s DESIGO PX PXM20 / PXM20-E operator unit User's guide Version 2.2 and later CM110754en_02 17 Dec 2009 Building Technologies Contents Revision history... 4 Reference to trade names and product names...

More information

5450 NW 33rd Ave, Suite 104 Fort Lauderdale, FL Fruitland Ave Los Angeles, CA UM Channel Monitor.

5450 NW 33rd Ave, Suite 104 Fort Lauderdale, FL Fruitland Ave Los Angeles, CA UM Channel Monitor. 5450 NW 33rd Ave, Suite 104 Fort Lauderdale, FL 33309 3211 Fruitland Ave Los Angeles, CA 90058 UM-600 6-Channel Monitor Version 2 Installation and Operation Manual Rev. G P/N145F-12990 PCO 00007462 (c)

More information

Data Center Energy Savings By the numbers

Data Center Energy Savings By the numbers Data Center Energy Savings By the numbers Chris Kurkjian, PE HP Critical Facility Services provided by EYP Mission Critical Facilities 2008 Hewlett-Packard Development Company, L.P. The information contained

More information

Brian Roberts & N. Amar Amarnani. County of Los Angeles - ISD

Brian Roberts & N. Amar Amarnani. County of Los Angeles - ISD HVAC Retro-commissioning Sustainable Savings with a Three-Prong Approach using Itron EEM Suite Brian Roberts & N. Amar Amarnani County of Los Angeles - ISD 1 Overview Process of HVAC retro-commissioning

More information

Smith Meter ETR-1000 Electronic Register

Smith Meter ETR-1000 Electronic Register MANUAL Smith Meter ETR-1000 Electronic Register Operator Reference Manual Bulletin MNTA001 Issue/Rev 0.1 (9/17) Technical Support Contact Information: Field Service Response Center 24/7 Technical Support/Schedule

More information

How to improve efficiency in Data Processing Centres (DPCs) The importance of knowing the PUE. center DPC

How to improve efficiency in Data Processing Centres (DPCs) The importance of knowing the PUE. center DPC 12 Technology for energy efficiency www.circutor.com Technical article Francisco Domínguez Network Quality Division How to improve efficiency in Data Processing Centres (DPCs) The importance of knowing

More information

Integrated Conference Bridge Professional

Integrated Conference Bridge Professional Title page Communication Server 1000 Integrated Conference Bridge Professional iii Nortel Communication Server 1000 Nortel Integrated Conference Bridge Professional Revision history June 2007 Standard

More information

MCS-CONNECT Quick Guide to Features

MCS-CONNECT Quick Guide to Features MCS-TOUCHSCREEN new touchscreen interface designed to simplify user access with the MCS-Magnum MCS-CONNECT Quick Guide to Features Real Time Graphs using MCS-Connect Live Graph MCS-CONNECT software is

More information

Centralized Controller Model: AG-150A

Centralized Controller Model: AG-150A Air-conditioner Network System Centralized Controller Model: AG-150A Instruction Book (Web browser for System maintenance engineer) Contents 1 Introduction... 1 1-1 Terms Used in This Manual...1 1-2 Computer

More information

DELIVERY SERVICE WEB SITE (DSWEB) PROCEDURES MANUAL

DELIVERY SERVICE WEB SITE (DSWEB) PROCEDURES MANUAL DELIVERY SERVICE WEB SITE (DSWEB) BGE - SUPPLIER EXCHANGE OF INFORMATION FOR GAS CHOICE PROGRAMS Table of Contents I. Introduction... 3 II. System Requirements... 3 III. Requesting Access to DSWeb... 3

More information

Home Monitoring and Control service provided by Verizon Online LLC

Home Monitoring and Control service provided by Verizon Online LLC Home Monitoring and Control service provided by Verizon Online LLC A separate subscription to Verizon FiOS TV is required for use with FiOS TV service. About This Manual This manual is designed for online

More information

Contents. System Properties...5

Contents. System Properties...5 User s Guide Contents Accessing Excel 5000 TM Open View Net Using Web Browser...1 About this Guide... 1 Introduction... 1 Architecture Diagram... 1 Getting Started... 2 Accessing Excel 5000 TM Open View

More information

Introduction. Thank you for purchasing an Electronic Message Center!

Introduction. Thank you for purchasing an Electronic Message Center! Introduction Congratulations on your purchase of an Electronic Message Center. The Message Center s EZ KEY II operation provides you with simple message entry and a wide variety of message features. EZ

More information

DNP Points List and Implementation

DNP Points List and Implementation S&C IntelliCap Plus Automatic Capacitor Control DNP Points List and Implementation Table of Contents Section Page Section Page DNP Points List for IntelliCap Plus Controls...1 Status Points....2 Analog

More information

MYRIAD QLC 4-CHANNEL MONITOR/CONTROLLER INSTRUCTION MANUAL

MYRIAD QLC 4-CHANNEL MONITOR/CONTROLLER INSTRUCTION MANUAL MYRIAD QLC 4-CHANNEL MONITOR/CONTROLLER INSTRUCTION MANUAL VISIT OUR WEBSITE SIGMACONTROLS.COM MYR QLC MANUAL 013114 2 TABLE OF CONTENTS INTRODUCTION 3 Ordering Information Specifications Features WIRING

More information

3000 CONTROLLER TRAINING MANUAL. April 26, 2012 Software Version

3000 CONTROLLER TRAINING MANUAL. April 26, 2012 Software Version 3000 CONTROLLER TRAINING MANUAL April 26, 2012 Software Version 1.59.03 Contents 3000 CONTROLLER USER GUIDE Quick Reference: Using the 3000... 3 Menu Summary Tree... 6 Main Menu: Programming your Fryer...

More information

SCI - NIH/NCRR Site. Web Log Analysis Yearly Report Report Range: 01/01/ :00:00-12/31/ :59:59.

SCI - NIH/NCRR Site. Web Log Analysis Yearly Report Report Range: 01/01/ :00:00-12/31/ :59:59. SCI - NIH/NCRR Site Web Log Analysis Yearly Report 2003 Report Range: 01/01/2003 00:00:00-12/31/2003 23:59:59 www.webtrends.com Table of Contents General Statistics...5 Page Views Over Time...8 Top Pages

More information

Touchpad User Guide. National Sales. Product Support. Freecall: Ph:

Touchpad User Guide. National Sales. Product Support. Freecall: Ph: Touchpad User Guide National Sales Ph: 1300 306 125 sales@ias.net.au Product Support Freecall: 1800 354 434 support@ias.net.au Designed and Manufactured in Australia by: Innovative Air Systems Pty Ltd.

More information

GV3000/SE 230 VAC 1-20 HP General Purpose (Volts/Hertz) and Vector Duty Drive Software Start-Up and Reference Manual Version 6.04

GV3000/SE 230 VAC 1-20 HP General Purpose (Volts/Hertz) and Vector Duty Drive Software Start-Up and Reference Manual Version 6.04 GV3000/SE 230 VAC 1-20 HP General Purpose (Volts/Hertz) and Vector Duty Drive Software Start-Up and Reference Manual Version 6.04 Instruction Manual D2-3387-4 The information in this manual is subject

More information

ISE Cyber Security UCITS Index (HUR)

ISE Cyber Security UCITS Index (HUR) ISE Cyber Security UCITS Index (HUR) Why Cybersecurity is important Data breaches have become almost commonplace in the last few years Cybersecurity focuses on protecting computers, networks, programs,

More information

Honeywell E-Mon Energy Software

Honeywell E-Mon Energy Software Honeywell E-Mon Energy Software QUICK START GUIDE INTRODUCTION Begin by reviewing this entire document to become familiar with the overall procedure steps. After completing each step in the procedure place

More information

Upgrading NIOS Software

Upgrading NIOS Software Upgrading NIOS Software Infoblox frequently releases updated NIOS software. Contact Infoblox Technical Support to learn which file name to use when downloading a new upgrade file, or watch your email for

More information