DualPAM Software Version 1.19 Release Note

Size: px
Start display at page:

Download "DualPAM Software Version 1.19 Release Note"

Transcription

1 DualPAM Software Version 1.19 Release Note Content 1 Software Installation 1.1 Download software from Walz homepage 1.2 Installation 1.3 Update Firmware Firmware check MEGA RISC processor TINY RISC processor 2 New features of Version Windows 8 compatibility established. 2.2 Triggered run error 2.3 Variable background color 3 New features of Version System Management Log File for improved user support Calibration PS I Fluorescence Light and temperature measurements USB connection Clock 3.2 New Experimental Options Sinus-shaped Actinic Illumination Maximum Illumination Width increased Actinic Light On after Fast Kinetics 3.3 Error Correction Fast Kinetics Trigger SP-Analysis Plot Flux Measurement Data export 3.4 Data handling Slow kinetics export Slow Kinetics Settings, Fast Kinetics Settings Flux Measurement Fo'/Fo 3.5 Script File Options New commands Repetition Blocks 4 New features of Version Major changes Light curves Triggered runs Fo mode Far red light intensity External trigger control Actinic light intensity setting P700 signal calibration Actinic light Single turn-over flash sequence New Script File Timing of script file command sequences Fast Kinetics 4.2 Minor changes Firmware update menu Fast kinetics file (*.DFK) Blue light checkbox Experimental time Greek characters 5 New features of Version New driver for USB serial port 5.2 New script file commands 5.3 Setting commands 5.4 Clock cycles 5.5 Slow kinetics 5.6 Maximum frequency of measuring light 5.7 Light curve 5.8 Curve difference and curve averaging 5.9 Interruption of USB communication 5.10 Clock 5.11 New clock-triggered events 5.12 Fast kinetics trigger 5.13 User settings 5.14 Actinic light intensities 5.15 Miscellaneous 6 DualPAM software Version 1.8 release note 6.1 General comments 6.2 Miscellaneous 6.3 Script files Heinz Walz GmbH Eichenring Effeltrich Germany DualPAM 1.19 Release Note Phone +49-(0)9133/ Telefax +49-(0)9133/5395 info@walz.com

2 DualPAM Software Version Software Installation 1.1 Download software from Walz homepage Installation Close all programs. Execute DualPAM setup.exe. Pass through installation process. Connect and switch on DUAL-PAM-100. Start DualPAM software. 1.3 Update Firmware Firmware check Note that from DualPAM version 1.16 on, firmware versions will be checked automatically. In case of outdated firmware, the user will be asked to update firmware MEGA RISC processor The current firmware version is displayed in the title bar of the DualPAM software window. The firmware version must be (Fw: ). To install firmware, proceed as described next: click <Firmware Update> and <Program MEGA RISC> click <Read Hex File> and <Download Hex File>, wait for completion of download click <Program RISC>, read and confirm warning during RISC programming, a status message is visible which is then replaced by a message box confirming instrument reset click <ok> to exit program modus prior to proceeding, establish computer to DUAL-PAM-100 communication by clicking on the red LED symbol in the upper left corner of the software window Successful firmware update can be checked by the command Read Firmware Version in the menu Firmware Update ; the title bar will display the current firmware version only after restart of the DualPAM software TINY RISC processor Note: before updating the TINY RISC, the MEGA RISC has to be updated. To update: click <Firmware Update> and <Program TINY RISC>, click <Read Hex File> and <Download Hex File>, wait for completion of download click <Program RISC>, read and confirm warning during RISC programming, a status message is visible which is then replaced by a message box confirming instrument reset click <ok> to exit program modus close and restart DualPAM program DualPAM 1.19 Release Note 2

3 2 New features of Version Windows 8 compatibility established. 2.2 Triggered run error Error in time scale (occurring when using triggered runs of previous DualPAM software) corrected. 2.3 Variable background color Variable background color in graphic windows (click Options Color Chart Background) 3 New features of Version System Management Log File for improved user support The behavior of DualPAM software during startup is recorded in the file DualPAM_COM.log which is located in the directory DualPAM. The Walz software team can use this log file to diagnose errors during program start Calibration During signal calibration, any active triggered run sequence is halted PS I Fluorescence The relative contribution of PS I to total Fo fluorescence is calculated online according to Pfündel et al. (2013) Photosynth Res: PRES2013a ( PSI Fluo display, bottom left corner of window) Light and temperature measurements Enhanced accuracy of light and temperature measurements by improved input calibration USB connection Reconnection after communication failure improved. USB 3.0 communication implemented Clock Accuracy of repetitive triggering (clock) improved by stopping online monitoring of fluorescence, P700, PAR and temperature inactivated 1 second prior to trigger time point. 3.2 New Experimental Options Sinus-shaped Actinic Illumination Actinic light (red, blue, far red) can be sine modulated with periods 1s Maximum Illumination Width increased Maximum time intervals for illumination by red, blue and far red light as well as for trigger output has been extended from 10 to 60 minutes (see window Actinic Light ) Actinic Light On after Fast Kinetics The option to reestablish previous actinic light conditions after fast kinetics has been introduced (Checkbox Keep AL after Kinetics in SP Trigger window. 3.3 Error Correction Fast Kinetics Trigger Error in Fast Kinetics trigger file Poly300ms.FTM corrected SP-Analysis Plot Ordinate scaling corrected. DualPAM 1.19 Release Note 3

4 3.3.3 Flux Measurement Calibration of flux signal corrected Data export Various errors related to formatting of numbers removed. 3.4 Data handling Slow kinetics export Several slow kinetics of Report can be selected and collectively exported as csv data Slow Kinetics Settings, Fast Kinetics Settings A list of all settings of Slow Kinetics and Fast Kinetics can be displayed by right click on button Copy Settings from Man. Rec Flux Measurement Flux rate is always given in ΔI I -1 msec -1. Therefore, the flux rate is independent from modulation frequency of actinic light. The Flux Multiplier applied during measurements is displayed in the offline mode. (For new information on DUAL-PAM-100 flux measurements see: Klughammer et al (PRES 2013b) Fo'/Fo Fo'/Fo can be displayed in the SP-Analysis und Light Curve graphical windows of DualPAM software. These ratios are entered in the Report file. Opening of old Report files missing Fo'/Fo switches software to offline. 3.5 Script File Options New commands If Temperature and Wait until Temperature permit triggering of commands depending on temperature. Else allows execution of one of two alternative commands depending on the state of a selected condition. are provided to control sinus modulation of actinic red and blue light as well as far red light Repetition Blocks Editing of repetition blocks improved: disabling the command Begin of Repetition Block automatically disabled the corresponding command End of Repetition Block and vice versa. End of Release Note for Version 1.18 (Next pages: notes to former versions) DualPAM 1.19 Release Note 4

5 4 New features of Version Major changes Light curves Export of light curve enabled Triggered runs In the earlier program versions, conflicts arose when the command Copy Triggered Run from Manual Record copied the commands used for Fo determination, that is, illumination by PS I light during an interval with actinic light switched off. Now, the Fo mode during measurements is not considered by the command Copy Triggered Run from Manual Record ; the Fo mode needs to be activated manually by checking the Fo box Fo mode In the Fo mode, 5 seconds of PS I illumination after saturation pulse is also applied under dark conditions (e.g. actinic light off for fluorescence recovery) Far red light intensity An error affecting correct display of far red light intensity is removed External trigger control The DUAL-PAM-100 is prepared for external triggering pressing the Ext. Trigger of the fast kinetics screen. The command Ext. Trigger is launching a window for external trigger control. When external triggering is primed, normal keyboard and mouse operation of the DUAL-PAM-100 is disabled Actinic light intensity setting Intensity setting 0 (zero) for blue and red actinic light is enabled. When automatic change of measuring light frequency is activated (Auto MF-High ON), and the level of actinic light intensity is 0, switching on the actinic light results only in an increase in measuring light frequency P700 signal calibration Signal calibration uses a fixed acquisition rate of 5 ms per data point. This means, calibration always requires 3 s and is independent of current slow kinetics acquisition rate. After calibration procedure the previous acquisition rate is restored Actinic light In addition to red actinic light, blue light, as well as blue and red light together, can be used as actinic illumination when the DualPAM routines Induction Curve and Light Curves are performed Single turn-over flash sequence Exactly timed sequences of single turn-over flashes can be delivered in the Fast Acquisition Mode. Single turn-over flash sequences can be defined in the window Pulse Widths which is available via the button Pulse Widths in the window Actinic Light, or directly by right-click on the ST button. Adjustable parameters are (1) numbers of flashes within a sequence, (2) time interval (width) between two flashes down to 10 ms, and (3) execution of fast kinetics measurement after the sequence. Pressing the ST button triggers a single turn-over flash sequence if the number of flashes in ST Pulse Sequence sequence is > 1. DualPAM 1.19 Release Note 5

6 New Script File Command TR Wait until Clock Counter Auto Fo' Select Act. Light ST sequence number ST sequence width Fast Kin. after ST sequence. GFS-3000 Command Group Actinic Light Condition General Settings Actinic Light Actinic Light GFS-3000 Action Applies 5V to TRIGGER OUT socket as defined in trigger settings. Continues script program depending on number of clock counter. Switches on or off the automatic Fo determination mode. Selects actinic light source (blue, red, or blue plus red) for automatic induction and light curves. Configures a series of exactly timed single turn-over flashes. To be active, the DualPAM software has to be in the in the Fast Kinetics Window of the Fast Acquisition Analysis Mode. This can be achieved by script file commands: Analysis Mode = Fast Acquisition Visible Page = SP Kinetics The script command SP triggers a series of flashes for ST sequence number > 1. A large number of commands designed to simultaneously operate the DUAL-PAM-100 and the GFS-3000 systems using the DUAL-PAM-100 Gas- Exchange Cuvette. A detailed description of these commands will be delivered with the DUAL-PAM-100 Gas-Exchange Cuvette Timing of script file command sequences During execution of a script command the execution of the succeeding command is automatically prevented; wait intervals to separate consecutive actions can be omitted Fast Kinetics Extended observation time for slow relaxation processes: By choosing acquisition points >32000 and checking Ext. time checkbox in the Fast Acquisition Settings menu, the total observation time can be extended by decreasing the acquisition rate at points >32000 and > This function requires MEGA RISC firmware version Minor changes Firmware update menu In the VIEW mode, the firmware update menu is disabled Fast kinetics file (*.DFK) Light intensity values (PAR, µmol m-2 s-1) of red and blue actinic light, saturation pulses and measuring light are saved together with fast kinetics data Blue light checkbox Removed in window for actinic light settings. DualPAM 1.19 Release Note 6

7 4.2.4 Experimental time On Slow Kinetics Settings window, the total experimental time resulting from number of points and rate is displayed Greek characters Greek characters are replaced by similar ASCII characters (e.g. µ u). 5 New features of Version New driver for USB serial port Adjustment of latency time to 1 ms is no longer required. 5.2 New script file commands P700 calibration: Automated routine for calibration of the scale of the P700 (or P515) difference signal. Measuring light MF Log: For measurements of fast fluorescence decay. The MF Log command decreases measuring light frequency logarithmically directly after maximum measuring light frequency (MF-max) is switched off. The MF log function can also be activated in the fast trigger window. Measuring light MF-M: Four levels of maximum frequency of measuring light are available (see below). Read with start conditions: Trigger files are saved together with the settings present at the trigger pattern s start. Load with start conditions: installs the trigger pattern selected and activates all start settings which influence the trigger-controlled fast kinetics. Display commands: A range of commands affecting the display of data has been added, for instance, automatic axis scaling and data averaging. 5.3 Setting commands New commands defining DUAL-PAM-100 settings have been added. Now, stored DUAL-PAM-100 settings can be activated (Open User Settings), detector heads can be defined and slow kinetic trigger files can be opened and executed. 5.4 Clock cycles The number of clocked events can be adjusted. 5.5 Slow kinetics Improved time management by coarse graphing of data in the presence of high rates of data acquisition (e.g. 1 point/ms) 5.6 Maximum frequency of measuring light The maximum measuring light frequency is adjustable at 4 different levels: 2000, 5000, and Hz. Note that these numbers correspond to frequencies of trains of 14 x 1.25 µs measuring pulses separated by 1.25 µs. The option of selecting among various maximum measuring light frequencies is not available when MF Log is selected. 5.7 Light curve A second model for analyzing light curve data has been implemented. DualPAM 1.19 Release Note 7

8 5.8 Curve difference and curve averaging Improved manual subtraction and manual averaging of slow and fast kinetics (see the <+> and <- > icons in the kinetics windows). 5.9 Interruption of USB communication Stable execution of DualPAM during interruption of USB connection Clock Clock stops when <Reset> or <New> is clicked during fast kinetics averaging New clock-triggered events Triggered run, actinic light on, and FR/BL switch Fast kinetics trigger Pretrigger conditions consistently used as starting conditions for main trigger pattern. <Clear All> sets all pretrigger and trigger signals to zero. The command <Synchronize ADC> can be activated by a checkbox. The <Synchronize ADC> is saved as part of the <Start Conditions> of a trigger file User settings Settings of country and format of numbers is saved with a user setting Actinic light intensities Actinic light intensities can be set to zero 5.15 Miscellaneous Error (EOF) during reading of report corrected. 6 DualPAM software Version 1.8 release note 6.1 General comments A software component has been implemented to operate the P515/535 module for measurements of electrochromic absorbance shift at 515 nm (P515) and absorbance changes at 535 nm (I 535). Expanded control of external PAR and temperature sensors are available via right-click on PAR and temperature display, respectively. Specifically: automatic dark offset adjustment for low and high PAR ranges, switching between external PAR and predefined internal PAR values, storage of sensor calibration data in the DualPAM.INI file. 6.2 Miscellaneous Improved memory management for long-term measurements. Removal of a bug which affected calculations of Φ(NO). A routine has been added to calculate the difference between two curves (Slow and fast kinetics. Available by clicking the dash button right of the <Save kinetics button>). DualPAM 1.19 Release Note 8

9 Improved performance of the functions <Copy Triggered Run from Manual Record> and <Pretrigger> in fast trigger settings. 6.3 Script files Script files are automatically placed into the DualPAM directory. The files adjust parameters and execute measuring routines of the Dual-PAM-100. A short description of the script files is given next. I1_Oszillation.prg Records 60 ms polyphasic rise kinetics interspaced by 60 seconds dark intervals. Prior to each polyphasic rise, various number of single turn-over flashes are given (ranging from zero to eight). Get_AL_Intensities.prg Writes photon flux densities as measured by a quantum sensor connected to the DUAL-C control unit into the internal list of actinic light intensities. Get_BL_Intensities.prg Writes photon flux densities as measured by a quantum sensor connected to the DUAL-C control unit into the internal list of blue light intensities. IC+LC.prg Runs a P700 + fluorescence induction curve and, subsequently, a light curve. P700 MT-Width.prg Records P700 kinetics for multiple turn-over flashes of increasing length. P700_FineAdjust.prg Automatically balances 830 sample and 875 reference beams. Pool+IC.prg Assesses intersystem electron carrier pool by P700 measurements and, subsequently, performs a P700 + fluorescence induction curve. Poly60ms.FTM Records 60 ms polyphasic rise. Poly300ms.FTM Records 300 ms polyphasic rise. Qa_Decay.FTM Measures decay kinetics after single turn-over flash. Kautsky01.STM Runs a Kautsky induction curve. DualPAM 1.19 Release Note 9

PHYTO-PAM-II Multiple Excitation Wavelength Phytoplankton & Photosynthesis Analyzer. Differential Analysis of Mixed Algae Samples

PHYTO-PAM-II Multiple Excitation Wavelength Phytoplankton & Photosynthesis Analyzer. Differential Analysis of Mixed Algae Samples PHYTO-PAM-II Multiple Excitation Wavelength Phytoplankton & Photosynthesis Analyzer Differential Analysis of Mixed Algae Samples PHYTO-PAM -II COMPACT VERSION One instrument one compact housing PHYTO-PAM-II

More information

Universal Light Meter

Universal Light Meter Universal Light Meter ULM-500 User Manual 7.100 / 06.2009 2 nd edition (May 2012) Heinz Walz GmbH, 2009 Heinz Walz GmbH Eichenring 6 91090 Effeltrich Germany Tel. +49-(0)9133 / 7765-0 Fax +49-(0)9133 /

More information

Standard Operating Procedure for the Horiba FluroMax-4

Standard Operating Procedure for the Horiba FluroMax-4 Standard Operating Procedure for the Horiba FluroMax-4 Adapted from Horiba Operations Manual Created by Michael Delcau, Modified by Brian Lamp The Fluoromax is capable of making a variety of measurements.

More information

Software Description GFS-3000 Control Unit Model 3000-C

Software Description GFS-3000 Control Unit Model 3000-C Software Description GFS-3000 Control Unit Model 3000-C Software Manual Supplement to the 6th Edition of the GFS-3000 Manual: 28-Mar-12 gfs-3000_manual_panelpc.doc 1.223 / 03.2012 Heinz Walz GmbH, 2012

More information

ic-mh16 Evaluation Software Software Description

ic-mh16 Evaluation Software Software Description Rev A1, Page 1/14 DESCRIPTION ic-haus ic-mh16 evaluation software is developed for PCs running the Windows operating system. The evaluation software is developed in LabVIEW and requires a one-time installation

More information

FluxGage. FluxGage. LED Luminaire Measurement System User Manual

FluxGage. FluxGage. LED Luminaire Measurement System User Manual FluxGage FluxGage LED Luminaire Measurement System User Manual 1 Acronyms... 3 2 Introduction... 4 2.1 Operation principle... 4 3 Specifications... 5 4 Mechanical and Electrical Installation... 9 4.1 Unpacking...

More information

Smart Monitor ZG2 User s Manual

Smart Monitor ZG2 User s Manual Smart Monitor ZG2 User s Manual Smart Sensors ZG2 Series 2D Profile Measuring Sensors CONTENTS SMART MONITOR ZG2 USER S MANUAL...1 SECTION 1 PREPARATIONS...2 Installing the Smart Monitor ZG2 on a Computer...

More information

Provide Accurate Results. Operational Manual. Visible Spectrophotometer. SP-880 Mate. PC Software. Metertech Inc. Version 1.2.3

Provide Accurate Results. Operational Manual. Visible Spectrophotometer. SP-880 Mate. PC Software. Metertech Inc. Version 1.2.3 Provide Accurate Results Operational Manual Visible Spectrophotometer SP-880 Mate PC Software Metertech Inc. Version 1.2.3 Metertech Inc. provides this publication as is without warranty of any kind, either

More information

About this Guide How the Document is Organized... 5 Definition of Terms Chapter 1 PMManager and Devices... 6

About this Guide How the Document is Organized... 5 Definition of Terms Chapter 1 PMManager and Devices... 6 Table of Contents About this Guide... 5 How the Document is Organized... 5 Definition of Terms... 5 Chapter 1 PMManager and Devices... 6 PMManager Features... 6 Package Contents... 6 System Requirements...

More information

D-ILA Projector JVC Projector Calibration Software 10 INSTRUCTIONS

D-ILA Projector JVC Projector Calibration Software 10 INSTRUCTIONS D-ILA Projector JVC Projector Calibration Software 10 About the marks being used in this manual INSTRUCTIONS X990R refers to as explanations/instructions for DLA-X990R series. X590R refers to as explanations/instructions

More information

Operating Manual. Intelligent Control for Outdoor Lighting. Intelligent Hand-held Unit. Operating Manual icti

Operating Manual. Intelligent Control for Outdoor Lighting. Intelligent Hand-held Unit. Operating Manual icti Operating Manual icti Intelligent Control for Outdoor Lighting Intelligent Hand-held Unit Operating Manual LiCS Outdoor icti 04/2015 I www.vossloh-schwabe.com The imcu is a multifunctional luminaire controller

More information

SENSORS & SYSTEMS By far the best solution

SENSORS & SYSTEMS By far the best solution SENSORS & SYSTEMS By far the best solution Data transmission, evaluation and visualization scancontrol Demo-Software 1.5 MICRO-EPSILON MESSTECHNIK GmbH & Co. KG Königbacher Strasse 15 D-94496 Ortenburg

More information

FLOWgate500. Software Manual. Software Manual FLOWgate500 Release 2.2. Revision number: V2.2. Manufacturer: SICK AG. Erwin-Sick-Str.

FLOWgate500. Software Manual. Software Manual FLOWgate500 Release 2.2. Revision number: V2.2. Manufacturer: SICK AG. Erwin-Sick-Str. FLOWgate500 Software Manual Software Manual FLOWgate500 Release 2.2 Revision number: V2.2 Manufacturer: SICK AG Erwin-Sick-Str.1 D-79183 Waldkirch Germany Place of manufacture: SICK Engineering GmbH Bergener

More information

RIVA / Athena Pro-Series ECU

RIVA / Athena Pro-Series ECU RIVA / Athena Pro-Series ECU USING SOFTWARE (MAYA) Running Maya for First Time Once installed, Maya is available in the Start menu under Programs -> Maya, or from a desktop short cut, if created. The first

More information

Student Quick Reference Guide

Student Quick Reference Guide Student Quick Reference Guide How to use this guide The Chart Student Quick Reference Guide is a resource for PowerLab systems in the classroom laboratory. The topics in this guide are arranged to help

More information

DATA LOGGER (Version V1.3)

DATA LOGGER (Version V1.3) WYLER AG Im Hölderli CH-8405 WINTERTHUR Switzerland Tel. 0041 (0) 52 233 66 66 Fax. 0041 (0) 52 233 20 53 Homepage: http://www.wylerag.com E-Mail: wyler@wylerag.com Operating instructions DATA LOGGER (Version

More information

Temperature-Humidity Sensor Configuration Tool Rev. A 1/25/

Temperature-Humidity Sensor Configuration Tool Rev. A 1/25/ Rev. A 1/25/213 172 Contents Contents Temperature-Humidity Sensor Configuration Tool... 3 Read Sensor Screen... 3 Manual Calibration Screen... 4 Register View Screen... 5 Modbus Registers... 6 Reprogram

More information

TSR 3DXP and TSR 6DXP User s Manual May 2011

TSR 3DXP and TSR 6DXP User s Manual May 2011 TSR 3DXP and TSR 6DXP User s Manual May 2011 13000-60200-MAN (Rev. 4) Table of Contents DTS Support... 3 Introducing the TSR 3DXP and TSR 6DXP Shock Recorders... 4 Overview of TSR Features... 4 Triaxial

More information

D-ILA Home Theater Projector "Projector Calibration Software"

D-ILA Home Theater Projector Projector Calibration Software D-ILA Home Theater Projector "Projector Calibration Software" INSTRUCTIONS About "Projector Calibration Software" "Projector Calibration Software" is a tool that enables the projector to be used in an

More information

ARES. User s Guide. Aprilia Racing Engine Setup. English version

ARES. User s Guide. Aprilia Racing Engine Setup. English version ARES Aprilia Racing Engine Setup User s Guide English version ARES user s guide 2/59 I. WARNINGS... 6 II. SOFTWARE AND ENGINE CONFIGURATION COMPATIBILITY... 6 III. BEFORE UPDATING ARES TO A NEWER VERSION...

More information

WLAN MIERUZZO BASIC SOFTWARE

WLAN MIERUZZO BASIC SOFTWARE DK-5000 Series WLAN MIERUZZO BASIC SOFTWARE USER S MANUAL DK-5005A, DK-5010A, DK-5030A DK-5005B, DK-5010B, DK-5030B DK-5005C, DK-5010C, DK-5030C DK-5005D, DK-5010D, DK-5030D This manual was last revised

More information

Model FP-6500 Spectrofluorometer Instruction Manual. FP-6500 for Windows

Model FP-6500 Spectrofluorometer Instruction Manual. FP-6500 for Windows Model FP-6500 Spectrofluorometer Instruction Manual FP-6500 for Windows P/N: 0302-9999 April 2000 Contents Safety Considerations...i Regulatory Statements... iii Preface... iv Installation Conditions...v

More information

RMS Monitoring Software System Operation

RMS Monitoring Software System Operation RMS Monitoring Software System Operation 2017 ROTRONIC AG Bassersdorf Switzerland 2017 ROTRONIC AG Bassersdorf Switzerland Page 2 of 27 Contents Contents... 3 1 Overview... 4 1.1 System Requirements...

More information

Connecting the LCD Race Display via Direct Ethernet Connection

Connecting the LCD Race Display via Direct Ethernet Connection Connecting the LCD Race Display via Direct Ethernet Connection Using the latest version of DataPro and upgrading the firmware on your Stack LCD Motorsport display provides important improvements to the

More information

QUANTAX EDS SYSTEM SOP

QUANTAX EDS SYSTEM SOP QUANTAX EDS SYSTEM SOP December 2017 Energy-Dispersive X-Ray Spectroscopy (EDS, EDX, EDXS or XEDS), is an analytical technique used for the elemental analysis or chemical characterization of a sample.

More information

User Manual. Recorder of environmental conditions THBR. Version: 2.0.2

User Manual. Recorder of environmental conditions THBR. Version: 2.0.2 User Manual Recorder of environmental conditions THBR Version: 2.0.2 2 TABLE OF CONTENTS 1. INTENDED USE... 4 2. INSTALLATION... 5 2.1. System requirements... 5 2.2. Installation process... 5 2.3. Program

More information

motcom loganalyser User Manual

motcom loganalyser User Manual User Manual Part No. 2 900 04 10000 Release 07.03.2016 English revision 160825 Kurt-Schumacher-Str. 28-30 66130 Saarbrücken, Germany e-mail: info@motcomgmbh.com web: www.motcomgmbh.com Contents Introduction...

More information

Using Flow Control with the HEAD Recorder

Using Flow Control with the HEAD Recorder 03/17 Using with the HEAD Recorder The HEAD Recorder is a data acquisition software program that features an editable function. This function allows complex program sequences to be predefined, which can

More information

D-ILA Home Theater Projector Projector Calibration Software 5 INSTRUCTIONS

D-ILA Home Theater Projector Projector Calibration Software 5 INSTRUCTIONS About the marks being used in this manual D-ILA Home Theater Projector Projector Calibration Software 5 INSTRUCTIONS X95R/X75R refers to as explanations/instructions for DLA-X95R and DLA-X75R. X900R/X700R

More information

Introduction. M A G L I N Samplers support data acquisition from the following data acquisition modules and instruments:

Introduction. M A G L I N Samplers support data acquisition from the following data acquisition modules and instruments: Introduction M A G L I N is a computer program designed to perform continuous unattended data acquisition from one or more instruments, with sampling rates typically between 0.01Hz and 800Hz. It has been

More information

DATA LOGGING SOFTWARE FOR 4-WAY BALL VALVE DIGITAL MANIFOLD

DATA LOGGING SOFTWARE FOR 4-WAY BALL VALVE DIGITAL MANIFOLD DATA LOGGING SOFTWARE FOR 4-WAY BALL VALVE DIGITAL MANIFOLD The Mastercool Data Logger Application provides all the necessary Recorder and Display Functions to record, display and save new data or playback

More information

MultiHandy Operating Instructions. Version 1.0 EN Firmware-Version 1.0 TKZ L EN

MultiHandy Operating Instructions. Version 1.0 EN Firmware-Version 1.0 TKZ L EN EN MultiHandy 2025 Operating Instructions Version 1.0 EN Firmware-Version 1.0 TKZ L3160-00-78.10EN OPERATING INSTRUCTIONS 1 Basics.............................. 1 1.1 Proper use...........................

More information

DwyerLog Logger Interface Software

DwyerLog Logger Interface Software DwyerLog Logger Interface Software USER S GUIDE Version 1.4x March 21, 2013 Dwyer Instruments, Inc 102 Indiana Hwy 212 Michigan City, IN 46360 Phone: (219) 879-8868 Fax: (219) 872-9057 http://www.dwyer-inst.com

More information

METS methane sensor SOFTWARE MANUAL UNDERWATER SENSORS FOR DISSOLVED GASES

METS methane sensor SOFTWARE MANUAL UNDERWATER SENSORS FOR DISSOLVED GASES METS methane sensor SOFTWARE MANUAL UNDERWATER SENSORS FOR DISSOLVED GASES - METS - Software Manual Release: Software v4.1.3, August 2006 Manual v4.1.5, July 2014 CONTENTS 1 SOFTWARE SYSTEM REQUIREMENTS

More information

Software Installation and Quick Start Guide. PowerMax-Pro PC

Software Installation and Quick Start Guide. PowerMax-Pro PC Software Installation and Quick Start Guide PowerMax-Pro PC Software Installation and Quick Start Guide PowerMax-Pro PC 27650 SW 95th Ave. Wilsonville, OR 97070 This document and software is copyrighted

More information

Navigator Software User s Manual. User Manual. Navigator Software. Monarch Instrument Rev 0.98 May Page 1 of 17

Navigator Software User s Manual. User Manual. Navigator Software. Monarch Instrument Rev 0.98 May Page 1 of 17 User Manual Navigator Software Monarch Instrument Rev 0.98 May 2006 Page 1 of 17 Contents 1. NAVIGATOR SOFTWARE 2. INSTALLATION 3. USING NAVIGATOR SOFTWARE 3.1 STARTING THE PROGRAM 3.2 SYSTEM SET UP 3.3

More information

MDE 184. A Manager vers. 4 for PDA. Installation and User Manual. A MANAGER Software for PDA Installation and User Manual

MDE 184. A Manager vers. 4 for PDA. Installation and User Manual. A MANAGER Software for PDA Installation and User Manual MDE 184 A Manager vers. 4 for PDA Copyright by BIFFI Italia. All right reserved MDE184/Rev.2 3 18-11-2014 Mod F02 new version D.Bellinzona A.Battaglia 2 06-05-2010 Mod. Instal F02-Permis. M. Giuliani A.

More information

User guide TMD2725 EVM. TMD2725 ALS and Proximity Sensor Evaluation Kit. Version 1.0

User guide TMD2725 EVM. TMD2725 ALS and Proximity Sensor Evaluation Kit. Version 1.0 User guide TMD2725 EVM TMD2725 ALS and Proximity Sensor Evaluation Kit Version 1.0 Contents 1 Establishing basic functionality... 5 2 TMD2725 EVM graphical user interface (GUI)... 5 2.1 Software overview...

More information

Spectrometer Visible Light Spectrometer V4.4

Spectrometer Visible Light Spectrometer V4.4 Visible Light Spectrometer V4.4 Table of Contents Package Contents...3 Trademarks...4 Manual Driver and Application installation...5 Manual Application Installation...6 First Start of the Application...8

More information

User Guide. Model Temperature Datalogger Kit Model Temperature and Humidity Datalogger Kit Model SW276 Datalogging Software SW276

User Guide. Model Temperature Datalogger Kit Model Temperature and Humidity Datalogger Kit Model SW276 Datalogging Software SW276 User Guide Model 42265 Temperature Datalogger Kit Model 42275 Temperature and Humidity Datalogger Kit Model SW276 Datalogging Software SW276 Introduction Congratulations on your purchase of Extech Instrument

More information

Vibration Analyzer Version 1.0.2

Vibration Analyzer Version 1.0.2 Vibration Research Corporation 6437 28 th Ave. Hudsonville, MI 49426 support@vibrationresearch.com Phone: (616) 669-3028 Fax: (616) 669-5337 Vibration Analyzer Version 1.0.2 File menu The File menu is

More information

R&S RTB2000 Oscilloscope Release Notes Firmware Version

R&S RTB2000 Oscilloscope Release Notes Firmware Version Oscilloscope Release Notes Firmware Version 02.202 These Release Notes describe the following models and options: R&S RTB2004 Oscilloscope, order no. 1333.1005K04 R&S RTB2002 Oscilloscope, order no. 1333.1005K02

More information

FT2 View Instruction Manual

FT2 View Instruction Manual 399 Reservation Road, Marina, California U.S.A. Ph: (831) 384-4300 Fax: (831) 337-5786 www.foxthermalinstruments.com 2006 Fox Thermal Instruments, Inc. 07/19/13 Introduction: The FT2 View application software

More information

Operating instructions. AUTOSEN:IO Version / / 2017

Operating instructions. AUTOSEN:IO Version / / 2017 Operating instructions AUTOSEN:IO Version 1.0 706434 / 01 02 / 2017 Contents 1 Preliminary note................................................ 3 1.1 Symbols used............................................

More information

DaqPRO Solution. User Guide INNOVATIVE MONITORING SOLUTIONS ALL IN ONE SOLUTION FOR DATA LOGGING AND ANALYSIS.

DaqPRO Solution. User Guide INNOVATIVE MONITORING SOLUTIONS ALL IN ONE SOLUTION FOR DATA LOGGING AND ANALYSIS. INNOVATIVE MONITORING SOLUTIONS www.fourtec.com User Guide including DaqLab FACTORIES Monitoring product quality throughout the entire manufacturing cycle TESTING STANDARDS Ensuring quality control and

More information

gapcontrol Setup Software 3.0 Instruction Manual

gapcontrol Setup Software 3.0 Instruction Manual gapcontrol Setup Software 3.0 Instruction Manual MICRO-EPSILON MESSTECHNIK GmbH & Co. KG Königbacher Strasse 15 94496 Ortenburg / Germany Tel. +49 (0) 8542 / 168-0 Fax +49 (0) 8542 / 168-90 info@micro-epsilon.de

More information

MCA8000D OPTION PA INFORMATION AND INSTRUCTIONS FOR USE I. Option PA Information

MCA8000D OPTION PA INFORMATION AND INSTRUCTIONS FOR USE I. Option PA Information MCA8000D Option PA Instructions and Information Rev A0 MCA8000D OPTION PA INFORMATION AND INSTRUCTIONS FOR USE I. Option PA Information Amptek s MCA8000D is a state-of-the-art, compact, high performance,

More information

User manual CORRIGO E Tool

User manual CORRIGO E Tool User manual CORRIGO E Tool Revision B Oct 2004 This user manual covers the CORRIGO E Tool for both heating and.ventilation This user manual is published by AB REGIN without guarantee. AB REGIN can at any

More information

SMFP2 RCS (Remote Control Software)

SMFP2 RCS (Remote Control Software) User Manual SMFP - SMFP2 RCS (Remote Control Software) V1.0 USER MANUAL V1.0 SMFP2 RCS (Remote Control Software) A simple tool for complex Rohde & Schwarz Mobile Tester Table of Content 2 1. Table of Content

More information

MIZ-21C Software Product Bulletin

MIZ-21C Software Product Bulletin Table of Content Table of Content... 2 Purpose of MIZ-21C Software 1.0.6... 3 Downloading and Installing MIZ-21C Software 1.0.6... 3 New Features in MIZ-21C Software 1.0.6... 4 Software Update Reliability...

More information

Testing and Diagnostics

Testing and Diagnostics Scope 3 Overview in real-time Signal analytics and diagnostics directly with the controller In the initial project design and also for commissioning or troubleshooting, transparent information concerning

More information

2 VARIO LUX CONTROL control buttons

2 VARIO LUX CONTROL control buttons VARIO LUX CONTROL with external control unit has connections provided for up to two fluorescent bars each with up to two channels and a temperature sensor for measuring the water temperature. VARIO LUX

More information

HCImage ORCA-Flash4.0 V2 Camera Guide

HCImage ORCA-Flash4.0 V2 Camera Guide HCImage ORCA-Flash4.0 V2 Camera Guide Release N/A December 2015 2015 Hamamatsu Corporation. All rights reserved. This guide, as well as the software described in it, is covered under license agreement

More information

Thermal Transient Test Installation and Operating Manual

Thermal Transient Test Installation and Operating Manual Thermal Transient Test Installation and Operating Manual 2705A De La Vina Street Santa Barbara, California 93105 Telephone (805) 682-0900 descon@silcom.com www. santabarbaraautomation.com Installation

More information

NORDSON CORPORATION AMHERST, OHIO USA

NORDSON CORPORATION AMHERST, OHIO USA CanWorks Operator Interface Tracking PLUS for CanWorks Systems with SM-2 Spray Monitors User Guide Part 1018132A NORDSON CORPORATION AMHERST, OHIO USA 2002 Nordson Corporation. All rights reserved. CanWorks,

More information

Software installation

Software installation Table of contents 1 Introduction...4 2 Software installation...4 2.1 Protection...4 2.2 Minimum recommended configuration...4 2.3 Installation...4 3 Uninstall the application...4 4 Software presentation...5

More information

Cal-Bay Systems XY Plotter, Time-Base Recorder, Automated Tester. Users Guide. Rev 3.1

Cal-Bay Systems XY Plotter, Time-Base Recorder, Automated Tester. Users Guide. Rev 3.1 Cal-Bay Systems XY Plotter, Time-Base Recorder, Automated Tester Users Guide Rev 3.1 Contents... 1 Quick Start Guide... 2 Selecting a Test Specification... 3 Clearing Traces... 4 Saving Traces...4 Loading

More information

ME 365 EXPERIMENT 3 INTRODUCTION TO LABVIEW

ME 365 EXPERIMENT 3 INTRODUCTION TO LABVIEW ME 365 EXPERIMENT 3 INTRODUCTION TO LABVIEW Objectives: The goal of this exercise is to introduce the Laboratory Virtual Instrument Engineering Workbench, or LabVIEW software. LabVIEW is the primary software

More information

User Manual WatchPower

User Manual WatchPower User Manual WatchPower Management Software for SP Efecto / SP Brilliant (Plus) / SP Initial Table of Contents 1. WatchPower Overview...1 1.1. Introduction... 1 1.2. Features... 1 2. WatchPower Install

More information

5 Setting Preferences 15 Preferences 15 Configure Chart Colors 16

5 Setting Preferences 15 Preferences 15 Configure Chart Colors 16 CRITERION Vantage 3 Acquire Training Manual Contents 1 Introduction 3 Collecting Data 3 2 Starting the Program 3 Logging In and Logging Out 3 Logging In 3 Logging in as an Administrator 3 Logging in as

More information

User Manual WatchPower

User Manual WatchPower User Manual WatchPower Management Software for Inverter Table of Contents 1. WatchPower Overview... 1 1.1. Introduction... 1 1.2. Features... 1 2. WatchPower Install and Uninstall... 1 2.1. System Requirement...

More information

Zelio Logic 2 Online Help

Zelio Logic 2 Online Help Page 1 of 234 Zelio Logic 2 Online Help Overview of the Zelio Soft 2 Software At a Glance Subject of this Section This section provides an overview of the Zelio Soft 2 software. What's in this Part? This

More information

User Manual PDUTracker

User Manual PDUTracker User Manual PDUTracker Management Software for PDU Table of Contents 1. Overview... 1 1.1. Introduction... 1 1.2. Features... 1 2. Install and Uninstall... 1 2.1. System Requirement... 1 2.2. Software

More information

TFA. KlimaLogg Pro. User Manual. Revision: 1.1

TFA. KlimaLogg Pro. User Manual. Revision: 1.1 TFA KlimaLogg Pro User Manual Revision: 1.1 Table of Contents Overview... 2 Getting Started... 2 Setting up the KlimaLogg Pro device... 2 Installing the USB-Stick... 2 Installation... 2 System Requirements...

More information

1.0 The System Architecture and Design Features

1.0 The System Architecture and Design Features 1.0 The System Architecture and Design Features Figure 1. System Architecture The overall guiding design philosophy behind the Data Capture and Logging System Architecture is to have a clean design that

More information

Sensor Control User Guide Version 2.6

Sensor Control User Guide Version 2.6 Sensor Control User Guide Version 2.6 Software for spectral sensors and devices User Guide Page 1 Disclaimer of Warranties IMPORTANT: Sensors, software, documentation, and other products offered by Spectral

More information

PeakTech. Manual. Software for PeakTech Digital Multimeter. DMM Tool

PeakTech. Manual. Software for PeakTech Digital Multimeter. DMM Tool PeakTech Manual Software for PeakTech Digital Multimeter Content PeakTech Content... 2 Installation... 2 Uninstallation... 5 Quick Start... 6 Graphical User Interface... 8 The LCD... 8 The Line Chart...

More information

BWSpec 4 Software User Manual. 19 Shea Way, Newark, DE Tel: (302) Fax: (302) Web:

BWSpec 4 Software User Manual. 19 Shea Way, Newark, DE Tel: (302) Fax: (302) Web: BWSpec 4 Software User Manual 290020235-G (09/16/2015) Copyright 2015 B&W Tek, Inc. Table of Contents 1 Introduction 1 2 Installation 1 2.1 Supported Operating Systems 1 2.2 Minimum System Requirements

More information

Vanderbilt Small Molecule NMR Center

Vanderbilt Small Molecule NMR Center Vanderbilt Small Molecule NMR Center Instructions for Using TOPSPIN version 2.0 DRX 400: Setting up 1H, 13C (1H decoupled), and 31P NMR Experiments Getting started: Sample Preparation: Make sure your sample

More information

SOFTWARE UPDATE NOTIFICATION (SUN) OMNISEC SOFTWARE v10.31: PSS

SOFTWARE UPDATE NOTIFICATION (SUN) OMNISEC SOFTWARE v10.31: PSS SOFTWARE UPDATE NOTIFICATION (SUN) OMNISEC SOFTWARE v10.31: PSS0051-05 Introduction This document details the installation and known issues with OMNISEC v10.31. This release is a maintenance release to

More information

SC-01 Data Logger Management Program Operator s Manual

SC-01 Data Logger Management Program Operator s Manual SC-01 Data Logger Management Program Operator s Manual Part Number: 71-0138RK Revision: P1 Released: 9/12/07 www.rkiinstruments.com Warranty RKI Instruments, Inc., warrants gas alarm equipment sold by

More information

41126 Cognento (MODENA) Italy Via Bottego 33/A Tel: +39-(0) Internet: Fax: +39-(0)

41126 Cognento (MODENA) Italy Via Bottego 33/A Tel: +39-(0) Internet:     Fax: +39-(0) QUICK ANALYZER User Guide Version 5.3 Index 1.0 Generality... 2 LICENSE AGREEMENT... 3 2.0 Channels Configuration... 4 2.1 IdroScan Data Log Management... 6 3.0 Test Results... 9 4.0 Excel Export... 10

More information

Getting Started. ATP 08 Online Analyzer. Introduction. Starting the Online Analyzer. HEAD Getting Started

Getting Started. ATP 08 Online Analyzer. Introduction. Starting the Online Analyzer. HEAD Getting Started ATP 08 Introduction With the ArtemiS (ATP08) you can analyze signals in real time with an extensive range of analysis functions, and you can average the signals and save the analysis results. The signals

More information

Instruction Manual. ROYTRONIC EXCEL Series AD9 Programming Guide Electronic Metering Pumps

Instruction Manual. ROYTRONIC EXCEL Series AD9 Programming Guide Electronic Metering Pumps Instruction Manual ROYTRONIC EXCEL Series AD9 Programming Guide Electronic Metering Pumps For file reference, please record the following data: Model No: Serial No: Installation Date: Installation Location:

More information

Step 1. Overview. Goal. System Requirements - 1 x WaveAce passive probe. Setup

Step 1. Overview. Goal. System Requirements - 1 x WaveAce passive probe. Setup Lab 6 EasyScope Remote Control (30 Minutes) Note:(Screenshots below show a white background configuration of your WaveAce to save black ink in printing, this configuration is explained in Lab 2 VIEW) Overview

More information

Engineering Project-I. Module 1: Familiarization of LabVIEW and the Vernier Toolkit

Engineering Project-I. Module 1: Familiarization of LabVIEW and the Vernier Toolkit Engineering Project-I Module 1: Familiarization of LabVIEW and the Vernier Toolkit PREPARED BY Academic Services Unit January 2012 Applied Technology High Schools, 2012 Module 1: Familiarization of LabVIEW

More information

Model ST370 Radiation Counter

Model ST370 Radiation Counter Model ST370 Radiation Counter ST370 Radiation Counter (Shown with GP35 and USB Cable) The ST370 Radiation Counter combines many features into a single inexpensive, computer-controlled instrument. It may

More information

MMA845xQ Sensor Toolbox User s Guide

MMA845xQ Sensor Toolbox User s Guide Freescale Semiconductor Document Number: MMA845xQSTUG User s Guide Rev. 1, 02/2012 MMA845xQ Sensor Toolbox User s Guide 1 Introduction The Freescale MMA845xQ sensor toolbox accelerometer kit provides hardware

More information

Service Manual !"#$%&'()*!"#$%& Ver Cat.-No.: 18076

Service Manual !#$%&'()*!#$%& Ver Cat.-No.: 18076 Service Manual!"#$%&'()*!"#$%& Ver. 1.02 Cat.-No.: 18076! +,-*./)(0/)1,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,, 2 3,-**4(5!675$%*5!$)$54()784758,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,

More information

Standard Operating Procedure of Triboindenter (Hysitron TI 950)

Standard Operating Procedure of Triboindenter (Hysitron TI 950) Standard Operating Procedure of Triboindenter (Hysitron TI 950) I Sample Loading and Preparation DO NOT TOUCH the bottom of transducer and optical microscope. Always place the tall samples on the most

More information

Ophir Centauri. High End Portable Laser Power/Energy Meter

Ophir Centauri. High End Portable Laser Power/Energy Meter Ophir Centauri High End Portable Laser Power/Energy Meter All the functionality you could have wanted in a high-end instrument, packed into a compact meter The Centauri s 7 touch-screen provides ease-of-use

More information

INCA-EIP V7.2 User s Guide

INCA-EIP V7.2 User s Guide INCA-EIP V7.2 User s Guide Copyright The data in this document may not be altered or amended without special notification from ETAS GmbH. ETAS GmbH undertakes no further obligation in relation to this

More information

On-Line Instrument Systems, Inc. 130 Conway Drive, Suites A & B, Bogart, GA (800) (706)

On-Line Instrument Systems, Inc. 130 Conway Drive, Suites A & B, Bogart, GA (800) (706) On-Line Instrument Systems, Inc. 130 Conway Drive, Suites A & B, Bogart, GA 30622 (800) 852-3504 (706) 353-6547 techsupport@olisweb.com www.olisweb.com Aminco Upgrade Software Manual For Olis Upgraded

More information

CLIQ Web Manager. User Manual. The global leader in door opening solutions V 6.1

CLIQ Web Manager. User Manual. The global leader in door opening solutions V 6.1 CLIQ Web Manager User Manual V 6.1 The global leader in door opening solutions Program version: 6.1 Document number: ST-003478 Date published: 2016-03-31 Language: en-gb Table of contents 1 Overview...9

More information

irc Pro (Not for diagnostic use)

irc Pro (Not for diagnostic use) irc Pro (Not for diagnostic use) User guide 2016 2 Table of Contents ircpro... 3 Overview... 3 Release notes... 4 Requirements... 5 Setup... 6 Setup by DVD... 7 Setup by Internet... 8 step 1 - Install

More information

Galaxie Photodiode Array Software

Galaxie Photodiode Array Software Varian, Inc. 2700 Mitchell Drive Walnut Creek, CA 94598-1675/USA Galaxie Photodiode Array Software User s Guide Varian, Inc. 2002-2006 03-914950-00:6 Table of Contents Introduction... 3 General... 3 PDA

More information

Addendum to S.U.N. for version 3.00

Addendum to S.U.N. for version 3.00 Filename: SUN for DTS v3.00 Addendum.doc Doct. Version No: 1 Date: August 2003 Author: M.T.Connah Product Software suite Product Zetasizer Nano series PartNo.-Issue PSS0012-01 PartNo./Version PSW0085/3.00

More information

PanelMate epro PS and epro PS Classic Restore Factory Image Load

PanelMate epro PS and epro PS Classic Restore Factory Image Load PanelMate epro PS and epro PS Classic Restore Factory Image Load Introduction There are 4 versions of the restore factory image load kits (catalog numbers 76MLPSD, 76MLPSB, 76MLPSCD, and 76MLPSCB). These

More information

UniPoint System Software User s Guide

UniPoint System Software User s Guide UniPoint System Software User s Guide LT2137 1998 Gilson, Inc. All rights reserved Exercise 3-Creating operations list... 4-22 Create and name operations list... 4-22 Set up steps... 4-23 Identify sample

More information

RMS Monitoring Software System Operation

RMS Monitoring Software System Operation System Operation 2016 ROTRONIC AG Bassersdorf Switzerland Contents Contents... 2 1 Overview... 3 1.1 System Requirements... 3 1.1.1 Browser... 3 2 System Login... 4 3 Data Views... 5 3.1 Alarm Symbols...

More information

Instruments Division. Service Kit for SML SML-Z Printed in the Federal Republic of Germany E-2

Instruments Division. Service Kit for SML SML-Z Printed in the Federal Republic of Germany E-2 Instruments Division Service Kit for SML SML-Z2 1090.5203.02 Printed in the Federal Republic of Germany 1090.5255.54 1 E-2 Contents 1 Service program... 8 1.1 Overview... Fehler! Textmarke nicht definiert.

More information

Fox Thermal Instruments, Inc.

Fox Thermal Instruments, Inc. Fox Thermal Instruments, Inc. THERMAL MASS FLOW METER & TEMPERATURE TRANSMITTER FT3 View www.foxthermalinstruments.com 399 Reservation Road Marina, CA. 93933 104845 Rev. D Notice FOX THERMAL INSTRUMENTS

More information

Fox Thermal Instruments, Inc.

Fox Thermal Instruments, Inc. Fox Thermal Instruments, Inc. THERMAL MASS FLOW METER & TEMPERATURE TRANSMITTER FT2A View www.foxthermalinstruments.com 399 Reservation Road Marina, CA. 93933 105406 Rev. A Notice FOX THERMAL INSTRUMENTS

More information

SysGauge SYSTEM MONITOR. User Manual. Version 4.7. Apr Flexense Ltd.

SysGauge SYSTEM MONITOR. User Manual. Version 4.7. Apr Flexense Ltd. SysGauge SYSTEM MONITOR User Manual Version 4.7 Apr 2018 www.sysgauge.com info@flexense.com 1 1 SysGauge Product Overview...3 2 SysGauge Product Versions...6 3 Product Installation...7 4 System Monitor

More information

LB5900 Series Sensor Unattended Operation Guide

LB5900 Series Sensor Unattended Operation Guide LB5900 Series Sensor Unattended Operation Guide LadyBug LB5900 series sensors with option UOP, (Unattended & Autonomous Operation), are capable of fully independent operation. The self-contained, highly

More information

VTR2535T-128K and VTR2535T-512K OCTAL 12bit 10MHZ TRANSIENT RECORDER

VTR2535T-128K and VTR2535T-512K OCTAL 12bit 10MHZ TRANSIENT RECORDER HYTEC ELECTRONICS Ltd HEAD OFFICE: 5 CRADOCK ROAD, READING, BERKS. RG2 0JT, UK Telephone: +44 (0) 118 9757770 Fax: +44 (0)118 9757566 NORTHERN OFFICE: 64 AMY Street, LEICESTER, LE3 2FB. Telephone: +44

More information

Studuino Programming Environment Manual

Studuino Programming Environment Manual Studuino Programming Environment Manual Ver 0.9.7 Jun. 02, 204 This manual explains the Studuino Programming Environment and how to use it. As the Studuino Programming Environment develops, this manual

More information

HSP Update Tool V5.9.0

HSP Update Tool V5.9.0 HSP Update Tool V5.9.0 Page 1 of 12 Copyright The data in this document may not be altered or amended without special notification from ETAS GmbH. ETAS GmbH undertakes no further obligation in relation

More information

Copyright ANRITSU. All rights reserved.

Copyright ANRITSU. All rights reserved. General Caution --------------- Please use a USB Memory Stick for firmware updates. If there is a firmware update question, please contact Anritsu service support at https://techsupport.anritsu.com, and

More information

Operating Procedure for Horiba Raman Microscope

Operating Procedure for Horiba Raman Microscope Operating Procedure for Horiba Raman Microscope SAFETY Be aware of Laser radiation at all times! Do not remove the covers of the instrument. Components are supplied with 110V electric source. Do not touch

More information