1 The Disk Drive Snap Server 4100 To install the new disk drive properly, follow the procedure carefully. Failure to follow instructions puts your data at risk. These preparatory steps assist you in completing the replacement procedure correctly. 1 Back up the data on your server. This step is required to protect your data adequately. 2 If you have Snap OS version 3.2 or earlier, upgrade to Snap OS 3.4, available from our Web site. 3 Once the data has been properly backed up and you have upgraded to Snap OS 3.4, identify and replace the defective drive by following the steps in this chapter. Identifying a Failed Disk Drive The Snap Server is factory-configured with all 4 disk drives as part of a RAID 5 array. If a disk drive fails, the corresponding drive LED on the front of the server flashes amber. To check disk drive status: 1 Use a Web browser to display the Snap Server Home page. (See your Administrator Guide for instructions.) 2 To display the Administration Home page, click the Administration link. (You may need to provide the Administrator password.) 3 To display the Disk Utilities page, click Disk Utilities. 4 Click the View Disk Status link. If the disk drives are configured as a RAID-5 array and functioning properly, you should see a single RAID-5 disk, with this icon:, and the status should read OK. Field Service Documentation 1

2 Identifying a Failed Disk Drive Snap Server If the status of the RAID-5 disk is BROKEN, check the disk status page for an orphan disk icon. The red orphan disk icon indicates that the failed disk drive is still accessible by the system and may not need to be replaced. This problem can occur when there is a loose cable to one disk drive. Open the server and check the cables to the affected disk drive. If you find a loose cable and reattach it, reconfigure the orphan disk as a spare. For instructions on checking the cables, see Checking for Loose Cables on page 5. If there is no orphan disk, you must replace the failed disk drive. 6 To determine which disk drive has failed, use a Web browser to connect to the Server Debug page at this address: where snap_server is the name or IP address of the Snap Server In the Command box on the Server Debug page, type info device and click OK. A list of the functioning disk drives appears, as shown on the next page. Look for a logical device labeled RAID5 Large data protection disk. The list should show that the logical device is made up of 4 partitions (drives) with the following partition numbers: You can assume that a disk drive that does not appear on this list has failed. Make a note of the failed disk drive s partition number (see the second screen for an example). 2 Field Service Documentation

3 Snap Server 4100 Identifying a Failed Disk Drive You use it to identify the disk drive after you have opened up the Snap Server case. A properly functioning system shows 4 partitions (disk drives). A system with disk drive failure shows a RAID CRACKED message. Partition/drive is missing. Field Service Documentation 3

4 Opening the Case Snap Server 4100 Opening the Case To replace a failed component, you need to open the Snap Server case. Caution There are high voltages inside the Snap Server. Always disconnect the power cable from any power source BEFORE opening the case. There are staticsensitive electronics inside the Snap Server. Make sure that you are working at a static-controlled workstation, and that you are properly grounded before handling any internal parts. To open the case: 1 Turn off the power on the server. 2 Unplug the AC power cord from the wall. 3 Loosen the 2 thumb screws at the rear of the top cover. 4 Slide the top cover toward the rear of the server until the rear edge can be lifted. 5 Lift the rear edge of the top cover and slide it toward the rear of the server until it can be lifted off of the server. 4 Field Service Documentation

5 Snap Server 4100 Locating a Failed Disk Drive Locating a Failed Disk Drive The disk drive map label on top of the power supply shows the physical location of the disk drive numbers. (If you do not know the number of the failed disk drive, see Identifying a Failed Disk Drive on page 1.) Disk Drive Map Drive Power supply Fan Drive Fan Front Drive Drive Motherboard Back Checking for Loose Cables If you have determined that the problem is an orphan disk drive that is operating properly but is disconnected from the RAID 5 array (see Identifying a Failed Disk Drive on page 1), you may be able to correct the problem by correcting loose connections to the problem disk drive. 1 Open the Snap Server case as described in Opening the Case on page 4. 2 Locate the failed disk drive as described in Locating a Failed Disk Drive on page 5. 3 Remove and reseat the ATA ribbon cable and the power cable connected to the problem disk drive. 4 Replace the cover. Field Service Documentation 5

6 Replacing a Disk Drive Snap Server If you reseated a loose cable in step 3, reconfigure the problem disk as described in Rebuilding the RAID Array on page 11. Replacing a Disk Drive Caution Disk drives are precision equipment. Handle them carefully, as any metalto-metal contact while handling them could result in loss of data and/or reduce the useful life of the disk drive. 1 Open the Snap Server case, as described in Opening the Case on page 4. 2 Locate the failed disk drive as described in Locating a Failed Disk Drive on page 5. 3 Using a 7-mm nut driver, remove the nut that attaches the drive bracket to the chassis. Set the nut aside for use later when installing the drive replacement. 4 Gently lift the front of the failed drive (located near the threaded chassis stud), slide the drive toward the front of the server, and then lift the drive out. Caution Be careful not to let the bracket touch the other disk drives while lifting it out of the server. 5 Carefully remove the ATA ribbon cable and the power cable from the failed disk drive. 6 Lay the drive upside down on a grounded, padded surface. 7 Using a #2 Phillips screwdriver, remove the 4 screws that attach the bracket to the failed disk drive. Note the orientation of the bracket and carefully remove it. Set the screws aside for use when you attach the bracket to the replacement disk drive. 8 Take the Overland Storage supplied Hard Drive Field Replacement Unit out of its package. 9 Set the jumpers on the replacement disk drive to configure the drive as a master. Each drive has a diagram on its label indicating the master and slave jumper settings. See the diagram for the jumper settings of the drive you are installing. If the drive is not already a master, configure the jumper settings to make it one. 10 Carefully place the bracket on the replacement drive in the correct orientation. 11 Using the 4 Phillips screws, attach the bracket to the replacement drive and make sure the screws are securely fastened. 6 Field Service Documentation

7 Snap Server 4100 Replacing the Cover 12 Gently slide the drive bracket into position, aligning the tabs on the chassis into the slots on the bracket. 13 Slide it in until the tabs are fully engaged with the slots, and lower the front end of the bracket over the threaded stud in the chassis. 14 Reattach the nut to the threaded stud, and tighten it. 15 Connect the ATA ribbon cable from the motherboard to the new disk drive. 16 Make sure that the cable is securely seated in the drive. 17 Connect the power cable to the new disk drive. 18 Again, make sure that the cable is securely seated in the drive. 19 Replace the cover on the Snap Server as described in Replacing the Cover on page 7. Replacing the Cover To replace the cover after servicing the Snap Server: 1 Slide the cover from the rear of the server toward the front, making sure that the front lip of the chassis hooks into the slot in the front edge of the cover. 2 Tighten the 2 thumb screws until they are snug. 3 Plug in the AC power and turn on the server. Caution There are high voltages inside the Snap Server. Always replace the cover BEFORE connecting the power cable to any power source. Checking Drive Partition Size 1 Once you have replaced the top cover and powered up the server, use a Web browser to log into the Administration page of your Snap Server. For more detailed instructions, see your Administrator Guide. 2 To connect to the Server Debug page, enter the following in the browser address line: where snap_server is the name or IP address of your Snap Server. 3 Press Enter. This brings up the Server Debug page. 4 In the Command box, type info device and click OK. Field Service Documentation 7

8 Checking Drive Partition Size Snap Server 4100 The partition information for each drive slot is displayed. 5 Compare the sizes (in KB) of the public partitions of each of the 4 drives. If the Single disk has a partition greater than or equal to the other 3 drives, as shown in the screen below, proceed to Rebuilding the RAID Array on page 11. If, as shown in the next screen, the Single disk partition size does not match the other 3 drives, and its partition size is smaller than the rest of the drives, proceed to Reconfiguring the Replacement Drive s Partition Size on page 9 to configure the drive correctly for the server. 8 Field Service Documentation

9 Snap Server 4100 Reconfiguring the Replacement Drive s Partition Size Example: for existing drives and for the replacement drive shows the replacement drive is smaller than the other drives. The Single disk partition size is smaller than the other drives in the RAID set. You must reconfigure the drive before it can join the RAID set. Reconfiguring the Replacement Drive s Partition Size 1 Using the table below, identify the Logical Device ID that belongs to the replacement drive you have just inserted into the Snap Server. For details of each drive s physical location, see the diagram on page 5. Physical Drive Location Logical Device ID Drive Drive Drive Drive It is important to have the correct Logical Device ID. Double-check to be sure of the correct the Logical Device ID for the drive that has been replaced. Field Service Documentation 9

10 Reconfiguring the Replacement Drive s Partition Size Snap Server In the command line type the following exactly as it appears: config device format 100XX /reinit /nocore where 100XX (followed by a space) is the Logical Device ID you identified in step 1, above. Note It is important to leave one space after the Logical Device ID and another after the reinit command. 3 You should see: The requested operation will be executed after the next reboot. If this message does not appear, 3 possibilities exist: If you entered the wrong Logical Device ID in step 2, a message appears below the command line indicating an error. Repeat step 2, using the correct Logical Device ID. If you made a random typing error in step 2, a message appears below the command line indicating an error. Repeat step 2, correcting the typing error. You omitted the space after the Logical Device ID and/or the space after the reinit command. In this case the drive reformats with an incorrect partition size. When the drive finishes reformatting, you must repeat step 2 and include both spaces. 4 In the Command box, type reboot and click OK. The Snap Server reboots and reinitializes the drive to the correct partition size. 5 When all disk activity stops, repeat the procedure in Checking Drive Partition Size on page 7 to verify that the Single disk partition size is greater than or equal to the other 3 drives in the RAID set. 10 Field Service Documentation

11 Snap Server 4100 Rebuilding the RAID Array See the next screen for an example. The replacement drive s partition size is The RAID set partition size is This is a good configuration. Now go on to Rebuilding the RAID Array. Rebuilding the RAID Array Using a Web browser, go to the Snap Administration page and click Disk Utilities. 1 Click Configure Disk, and then select Create a Disk Configuration. The only option available should be Spare. Caution If there is more than one drive to choose at this time, stop and contact Overland Storage Technical Support. Failure to do this may put your data at risk. If there is only one drive to choose, continue to step 2, below. 2 Select the option Spare and select the replacement drive to configure as the spare. Click Next, and then click Finish on the next page. The Snap Server may or may not reboot. In either case, the server incorporates the spare into the RAID array and automatically rebuilds the array. If the system still has not accepted your replacement drive into the RAID array, contact Overland Storage Technical Support. Field Service Documentation 11

Serial ATA Hot Swap Drive Cage Upgrade Kit for: Intel Server Chassis SC5200 Intel Server Chassis SC5250-E

Serial ATA Hot Swap Drive Cage Upgrade Kit for: Intel Server Chassis SC5200 Intel Server Chassis SC5250-E Serial ATA Hot Swap Drive Cage Upgrade Kit for: Intel Server Chassis SC5200 Intel Server Chassis SC5250-E A Guide for Technically Qualified Assemblers of Intel Identified Subassemblies/Products Order Number:

More information

Adding or Replacing a PCI Card

Adding or Replacing a PCI Card Caution There are static-sensitive electronics inside the unit. Before you handle any parts, make sure you are working at a static-controlled workstation and that you are properly grounded. Three PCI cards

More information

Snap Server 4400 Power Supply

Snap Server 4400 Power Supply Snap Server 4400 Power Supply Snap Server 4400 Note You can set up your system to send an e-mail alert in the event of a hardware failure. For details, see the section on e-mail notification in your Administrator

More information

Installing and Removing SDRAM and DRAM

Installing and Removing SDRAM and DRAM CHAPTER 4 This chapter explains how to remove and replace the main memory modules on the network processing engine or network services engine. For the location of the memory module you are replacing, find

More information

Oracle <Insert Picture Here>

Oracle <Insert Picture Here> Slide 1 Oracle Slide 2 WZT-6509 version B Sun Fire Nehalem and Westmere Rack-Mount Server Installation and Replacement Welcome to the installation and replacement

More information

Replacing the SATA PCI Controller Card

Replacing the SATA PCI Controller Card Replacing the internal controller PCI card may be performed by a single administrator; no tools are necessary. Caution There are static-sensitive electronics inside the unit. Before you handle any parts,

More information

Managing Individual Components

Managing Individual Components CHAPTER 3 This chapter describes how to install the Field Replaceable Units (FRUs) in the Cisco SFS 7008P system. About the Field Replaceable Units The following Field Replaceable Units (FRUs) are a part

More information

INSTALLING OR UPGRADING THE DVR S HDD

INSTALLING OR UPGRADING THE DVR S HDD AHD & NVR SERIES INSTALLING OR UPGRADING THE DVR S HDD www.nightowlsp.com Installing or Upgrading the DVR s HDD Most DVR s included in our kits already have a pre-installed internal HDD and is ready to

More information

Upgrading and Servicing Guide

Upgrading and Servicing Guide Upgrading and Servicing Guide The only warranties for Hewlett-Packard products and services are set forth in the express statements accompanying such products and services. Nothing herein should be construed

More information

Upgrading and Servicing Guide

Upgrading and Servicing Guide Upgrading and Servicing Guide The information in this document is subject to change without notice. Hewlett-Packard Company makes no warranty of any kind with regard to this material, including, but not

More information

Installing and Upgrading Memory and Virtual Private Network Modules

Installing and Upgrading Memory and Virtual Private Network Modules APPENDIX C Installing and Upgrading Memory and Virtual Private Network Modules This chapter tells how to install or upgrade memory and how to install a Virtual Private Network (VPN) module in your Cisco

More information

Upgrading and Servicing Guide

Upgrading and Servicing Guide Upgrading and Servicing Guide The only warranties for Hewlett-Packard products and services are set forth in the express statements accompanying such products and services. Nothing herein should be construed

More information

Replacing a Disk Drive

Replacing a Disk Drive Note Prior to using this procedure, verify that the seal label located on the bottom front of the unit reads, Please read HDD FRU documentation before opening. If this statement does not appear on the

More information

Installation Instructions

Installation Instructions Installation Instructions Kit Core Upgrade-EMB-B75B Without Modem Kit #22166905 These instructions outline the procedures to install the EMB-B75B motherboard into your existing Computer Core Chassis. There

More information

Upgrading and Servicing Guide

Upgrading and Servicing Guide Upgrading and Servicing Guide The information in this document is subject to change without notice. Hewlett-Packard Company makes no warranty of any kind with regard to this material, including, but not

More information

Computer Assembly (Installing Mother Board & CPU)

Computer Assembly (Installing Mother Board & CPU) Computer Assembly (Installing Mother Board & CPU) IT@SCHOOL HARDWARE TEAM Biju Thiruvananthapuram Sree Kumar Kottarakkara Shamsudeen Attingal Pradeep Mattara Wandoor Pre-Installation Precaution Mother

More information

V5420 Host Card Upgrade Kit for R3082D Quick Start Guide

V5420 Host Card Upgrade Kit for R3082D Quick Start Guide Quick Start Guide Upgrade kit contents The table below shows the contents of the V5420 Host Card Upgrade Kit (components are not shown to scale). Part Function Pieces V5420 Host Card 1 Host card bracket

More information

Chapter 3 Installation

Chapter 3 Installation Installation Chapter 3 Installation This chapter will guide you through the installation of your I/ O Extension A.3 board. It includes instructions on how to set the I/O port address and interrupt request

More information

Ion Memory Upgrade. Visit the AMI Entertainment Web site PM

Ion Memory Upgrade. Visit the AMI Entertainment Web site   PM Ion Memory Upgrade Visit the AMI Entertainment Web site http://www.meritgames.com PM0672-04 COPYRIGHT 2011 AMI ENTERTAINMENT NETWORK, INC. Ion Memory Upgrade CONTENTS: QTY PART NUMBER DESCRIPTION 1 EC0146-06

More information

Installation Note. Enhanced Memory Upgrade Kit (Option B72) for Agilent ESA-E Series and ESA-L Series Spectrum Analyzers

Installation Note. Enhanced Memory Upgrade Kit (Option B72) for Agilent ESA-E Series and ESA-L Series Spectrum Analyzers Installation Note Enhanced Memory Upgrade Kit (Option B72) for Agilent ESA-E Series and ESA-L Series Spectrum Analyzers Part Number E4401-90498 Supersedes: E4401-90332 Printed in USA July 2005 Notice.

More information

DualShock 4 Touch Pad Replacement. Remove the touchpad on the Dualshock 4 controller. Rédigé par: Mark. ifixit CC BY-NC-SA fr.ifixit.

DualShock 4 Touch Pad Replacement. Remove the touchpad on the Dualshock 4 controller. Rédigé par: Mark. ifixit CC BY-NC-SA fr.ifixit. DualShock 4 Touch Pad Replacement Remove the touchpad on the Dualshock 4 controller. Rédigé par: Mark ifixit CC BY-NC-SA fr.ifixit.com Page 1 de 9 INTRODUCTION Use this guide to remove a defective touchpad

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS 19 20 21 01 07 22 23 13 10 12 08 17 18 11 02 14 15 04 03 16 WELCOME PARTS LIST Thank you for purchasing this HealthPoint Technology Cabinet from Humanscale! Before you begin installing

More information

Removal and Replacement of the Serrano and Corsica Boards

Removal and Replacement of the Serrano and Corsica Boards Removal and Replacement of the Serrano and Corsica Boards 1. Purpose The purpose of this procedure is to document the removal and replacement of the Serrano and Corsica board of the Deko/Thunder Assemblies.

More information

AF Upgrade Instructions

AF Upgrade Instructions 8602 8631AF Upgrade Instructions Bering Technology, Inc. 1400 Dell Avenue, Suite B Campbell CA 95008-6620 (408) 364-6500 FAX: (408) 364-6501 Email: info@bering.com Contents 15-18631-81 Revision D This

More information

To connect the AC adapter:

To connect the AC adapter: Replacing the AC Adapter Replacing the AC Adapter 3 Plug the power cord into a wall outlet. The power indicator turns on. To connect the AC adapter: Connect the power cord to the AC adapter. Power indicator

More information

Replacing the PanelMate Power Pro 1785 Series, PanelMate epro 7585x-8 and 7685x-8 Series Backlight Assembly

Replacing the PanelMate Power Pro 1785 Series, PanelMate epro 7585x-8 and 7685x-8 Series Backlight Assembly Replacing the PanelMate Power Pro 1785 Series, PanelMate epro 7585x-8 and 7685x-8 Series Assembly Introduction The Replacement Kit provides a replacement backlight for the PanelMate Power Pro 1785 Series,

More information

DualShock 4 Touch Pad Replacement. Remove the touchpad on the Dualshock 4 controller. Scritto Da: Mark. ifixit CC BY-NC-SA it.ifixit.

DualShock 4 Touch Pad Replacement. Remove the touchpad on the Dualshock 4 controller. Scritto Da: Mark. ifixit CC BY-NC-SA it.ifixit. DualShock 4 Touch Pad Replacement Remove the touchpad on the Dualshock 4 controller. Scritto Da: Mark ifixit CC BY-NC-SA it.ifixit.com Pagina 1 di 9 INTRODUZIONE Use this guide to remove a defective touchpad

More information

Section. Service & Maintenance. - Core & Hard Disk Drive (HDD) - Amplifier - Monitor - UPS - Dollar Bill Acceptor - Fan Filter G - 1

Section. Service & Maintenance. - Core & Hard Disk Drive (HDD) - Amplifier - Monitor - UPS - Dollar Bill Acceptor - Fan Filter G - 1 Section G Service & Maintenance - Core & Hard Disk Drive (HDD) - Amplifier - Monitor - UPS - Dollar Bill Acceptor - Fan Filter G - 1 Core Removal Core & HDD 1. Open the door. 2. Perform shutdown procedure.

More information

Replacing Preamplifier Circuit Boards

Replacing Preamplifier Circuit Boards Instruction Guide Replacing Preamplifier Circuit Boards Before you begin This instruction sheet applies to the Plexon PBX-series preamplifiers. Use these instructions to expand, replace, or upgrade the

More information

TIVO UPGRADE INSTRUCTIONS (c) , Adberg Consulting LLC. All rights reserved.

TIVO UPGRADE INSTRUCTIONS (c) , Adberg Consulting LLC. All rights reserved. TIVO UPGRADE INSTRUCTIONS (c) 2001-2003, Adberg Consulting LLC. All rights reserved. Instructions for Series 1 DirecTV/TiVo GXCEBOT TWO-DRIVE REPLACE upgrade Color instructions are also available at http://www.weaknees.com/upgrade_instructions.php

More information

Allworx 24x Service and Troubleshooting Guide

Allworx 24x Service and Troubleshooting Guide Allworx 24x Service and Troubleshooting Guide -PAGE INTENTIALLY LEFT BLANK- Table of Contents 1 Safety Instructions...1 1.1 Electrical...1 1.2 Electrostatic Discharge...1 2 Chassis Views...2 3 Exterior

More information

How to add a Second Drive to a Mac mini (2012) using the OWC Data Doubler SSD/2.5 Installation Kit

How to add a Second Drive to a Mac mini (2012) using the OWC Data Doubler SSD/2.5 Installation Kit Instructional Video Series How to add a Second Drive to a Mac mini (2012) using the OWC Data Doubler SSD/2.5 Installation Kit Skill Level: Challenging Time to Complete: Approximately 45 Minutes Required

More information

SCSI Cable Installation Instructions

SCSI Cable Installation Instructions Identifying the SCSI Cable Parts SCSI Cable Installation Instructions for HP ProLiant DL100 Series Generation 2 Servers Item Description 1 Connector end 2 240 mm location 3 Terminator end Read instructions

More information

MegaRAID CacheVault Flash Module 02

MegaRAID CacheVault Flash Module 02 MegaRAID CacheVault Flash Module 02 Quick Installation Guide 53378-00, Rev. B MegaRAID CacheVault Flash Module CVFM02 Quick Installation Guide Revision History Version and Date Description of Changes 53378-00,

More information

Gateway Profile 4 service guide

Gateway Profile 4 service guide Gateway Profile 4 service guide Customizing Troubleshooting Contents Replacing Components in Your Gateway Profile 4.................. 1 About this guide.....................................................

More information

TDM To MiniMech conversion ProceDure

TDM To MiniMech conversion ProceDure TDM To MiniMech conversion ProceDure (Model 9100 ATM) TDN 07102-00079 Apr 1 2009 CorporATe HeAdquArTers: 522 E. Railroad Street Long Beach, MS 39560 PHONE: (228) 868-1317 FAX: (228) 868-0437 COPYRIGHT

More information

TIVO DVR UPGRADE INSTRUCTIONS (#80-HD)

TIVO DVR UPGRADE INSTRUCTIONS (#80-HD) TIVO DVR UPGRADE INSTRUCTIONS (#80-HD) (c) 2001-2006, weaknees. All rights reserved. Instructions for TwinBreeze HR10-250 DVR Upgrade Bracket/Kit Instructions are available online (in COLOR) at http://www.weaknees.com

More information

Sound Card Installation for Windows 95/98

Sound Card Installation for Windows 95/98 Sound Card Installation for Windows 95/98 Hardware Installation 1. Shut down Windows and power down system. Unplug power cable from the system. 2. Remove screws and open system enclosure. 3. Remove static

More information

Installing the Cisco ADE 2130 and 2140 Series Appliance Hardware Options

Installing the Cisco ADE 2130 and 2140 Series Appliance Hardware Options CHAPTER 4 Installing the Cisco ADE 2130 and 2140 Series Appliance Hardware Options This chapter provides instructions for installing, replacing, and removing various hardware options in your Cisco ADE

More information

Replacing the Battery HP t5730 and t5735 Thin Clients

Replacing the Battery HP t5730 and t5735 Thin Clients Replacing the Battery HP t5730 and t5735 Thin Clients Copyright 2009 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Microsoft and Windows

More information

256 Kbytes (1771-DRS) 1 Mbyte (1771-DRS1) 4 Mbytes (1771-DRS4) Installation Data

256 Kbytes (1771-DRS) 1 Mbyte (1771-DRS1) 4 Mbytes (1771-DRS4) Installation Data Installation Data You can add static RAM memory to your control coprocessor main module to expand user memory. The RAM single inline memory module (SIMM) is available in the following sizes: 256 Kbytes

More information

DNS User Manual. Version Dec DataON Storage, storage division of Area Data Systems.

DNS User Manual. Version Dec DataON Storage, storage division of Area Data Systems. DNS-2670 User Manual Version Dec. 2015 DataON Storage, storage division of Area Data Systems. Contents 1 Introduction... 1 1.1 System Overview... 3 1.1.1 System Top View...3 1.1.2 Front View...4 1.1.3

More information

Codonics Virtua Virtua-2 Optical Drive Replacement

Codonics Virtua Virtua-2 Optical Drive Replacement Codonics Virtua Virtua-2 Optical Drive Replacement Technical Brief Overview This document describes the procedure for replacing an optical drive on a Codonics Virtua Medical Disc Publisher, Virtua-2 model.

More information

Rack Installation Instructions

Rack Installation Instructions Rack Installation Instructions For System Storage EXP2512 and EXP2524 Express Storage Enclosures Use the instructions in this document to install an IBM System Storage EXP2512 Express Storage Enclosure

More information

Contivity Extranet Switch Installing Hardware Options Guide

Contivity Extranet Switch Installing Hardware Options Guide Contivity Extranet Switch Installing Hardware Options Guide Part Number 302283-B Rev.00 Installing LAN and WAN Option Cards...2 System Board Layouts... 2 Removing the 4500 Option Card Tray... 5 4500 Option

More information

Upgrading and Servicing Guide

Upgrading and Servicing Guide Upgrading and Servicing Guide Copyright Information The only warranties for Hewlett-Packard products and services are set forth in the express statements accompanying such products and services. Nothing

More information

DP SATA 6Gb/s PCIe i/e Quick Installation Guide

DP SATA 6Gb/s PCIe i/e Quick Installation Guide DP SATA 6Gb/s PCIe i/e Quick Installation Guide Introducing the SATA 6Gb/s PCIe i/e The DP SATA 6Gb/s PCIe i/e adds 2 SATA 6Gb/s & a PATA connectors to PCIe-equipped computers. Features and Benefits Dual

More information

Addendum for Tempo HD (Without Drive)

Addendum for Tempo HD (Without Drive) Addendum for Tempo HD (Without Drive) You Should Have (Part Number THD-M) In addition to the parts listed on the Tempo HD quick start guide, the following items should be included in your product package:

More information

User Guide. Intel NUC 8 Business, a Mini PC with Windows 10 NUC8i7HNKQC. Intel NUC 8 Enthusiast, a Mini PC with Windows 10 NUC8i7HVKVA

User Guide. Intel NUC 8 Business, a Mini PC with Windows 10 NUC8i7HNKQC. Intel NUC 8 Enthusiast, a Mini PC with Windows 10 NUC8i7HVKVA Intel NUC 8 Business, a Mini PC with Windows 10 NUC8i7HNKQC Intel NUC 8 Enthusiast, a Mini PC with Windows 10 NUC8i7HVKVA User Guide 1 Before You Begin CAUTIONS The procedures in this user guide assume

More information

120Ra-1 Pentium III Processor Installation Insert

120Ra-1 Pentium III Processor Installation Insert 120Ra-1 Pentium III Processor Installation Insert PN: 455-01614-000 Proprietary Notice and Liability Disclaimer The information disclosed in this document, including all designs and related materials,

More information

Written By: John Sutton

Written By: John Sutton Replacing the fan on your HP g7-2275 dx. Written By: John Sutton ifixit CC BY-NC-SA www.ifixit.com Page 1 of 20 INTRODUCTION Laptop cooking your lap? This guide will walk you through replacing your fan.

More information

RMX 2000 MPM to MPM+ Migration Procedure

RMX 2000 MPM to MPM+ Migration Procedure RMX 2000 MPM to MPM+ Migration Procedure When upgrading from version 2.x/3.x or 4.0.x, the migration procedure involves two main steps: Upgrading from version 2.x/3.x to version 4.1.1 (described in this

More information

Removing and Replacing FRUs from the Cisco ASR 1001-X Router

Removing and Replacing FRUs from the Cisco ASR 1001-X Router Removing and Replacing FRUs from the Cisco ASR 1001-X Router This chapter describes procedures for removing and replacing field-replaceable units (FRUs) from Cisco ASR 1001-X Routers. This chapter contains

More information

Replacing the Power Supply

Replacing the Power Supply APPENDIX B This appendix includes information on how to replace the power supply for the Cisco AS550XM universal gateway and contains the following sections: Safety Recommendations, page B-1 Required Tools

More information

E4233. English. P-Series. ASUS PC (Desktop Barebone) Installation manual. Download the latest manual from the ASUS website:

E4233. English. P-Series. ASUS PC (Desktop Barebone) Installation manual. Download the latest manual from the ASUS website: E P-Series ASUS PC (Desktop Barebone) Installation manual P P Download the latest manual from the ASUS website: www.asus.com Front/Rear panel features P Front (Close) P Front (Close) Front (Open) Rear

More information

ATTENTION: OBSERVE PRECAUTIONS FOR HANDLING ESD-SENSITIVE DEVICES

ATTENTION: OBSERVE PRECAUTIONS FOR HANDLING ESD-SENSITIVE DEVICES Hard Drive Removal IMPORTANT NOTE: If you are replacing a PATA hard drive with a SATA hard drive, please see PATA to SATA Hard Drive Conversion. Hard Drive Identification: To determine whether your hard

More information

Replacing the Hardware Configuration Option EPROM on the 1822

Replacing the Hardware Configuration Option EPROM on the 1822 MPMS Service Note 1014-806 Replacing the Hardware Configuration Option EPROM on the 1822 When you install an MPMS option, you will use these procedures to replace the hardware configuration option EPROM

More information

System Storage EXP3000 Rack Installation Instructions

System Storage EXP3000 Rack Installation Instructions System Storage EXP3000 Rack Installation Instructions Review the documentation that comes with your rack cabinet for safety and cabling information. When you install the IBM System Storage EXP3000 in a

More information

Upgrading and Servicing Guide

Upgrading and Servicing Guide Upgrading and Servicing Guide Copyright Information The only warranties for Hewlett-Packard products and services are set forth in the express statements accompanying such products and services. Nothing

More information

E2460GS Oscilloscope Upgrade Kit

E2460GS Oscilloscope Upgrade Kit Installation Instructions for E2460GS Oscilloscope Upgrade Kit Agilent 1670G-Series Logic Analyzers This kit upgrades either the Agilent Technologies 1670G, Agilent 1671G, Agilent 1672G, or the Agilent

More information

Installation Guide. Copyright 2005 MSI Computer Corp.

Installation Guide. Copyright 2005 MSI Computer Corp. Installation Guide Copyright 2005 MSI Computer Corp. Overview: 1013 is shipped out as a barebone. Some of the components are equipped while some are not. This installation guide provides you with the information

More information

efolder Replibit Pro Appliance Maintenance Manual (Pro 3000, 6000, 9000, and models) Replibit Pro Appliance Maintenance Manual

efolder Replibit Pro Appliance Maintenance Manual (Pro 3000, 6000, 9000, and models) Replibit Pro Appliance Maintenance Manual efolder Replibit Pro Appliance Maintenance Manual (Pro 3000, 6000, 9000, 12000 and 15000 models) 2016 efolder, Inc. All rights reserved. Last Update: November 2016 Page 1 Customer Support At efolder, we

More information

Replacing/Upgrading Mac Pro Processors (Early 2008)

Replacing/Upgrading Mac Pro Processors (Early 2008) Replacing/Upgrading Mac Pro Processors (Early 2008) The steps in this procedure illustrate how to remove the lower processor (CPU B). The instructions are the same for removing the upper processor (CPU

More information

EMC 10T "CE" Mechanical Upgrade Procedure

EMC 10T CE Mechanical Upgrade Procedure EMC 10T "CE" Mechanical Upgrade Procedure Kit Part Number: 009866-01 This procedure upgrades a non-ce compliant machine to the mechanical requirements of a CE compliant machine. Properly upgraded machines

More information

Canon EOS Rebel T2i Top Cover Replacement

Canon EOS Rebel T2i Top Cover Replacement Canon EOS Rebel T2i Top Cover Replacement Replacing the top piece of a Canon T2i (550D). In my case, I had a broken hot-shoe, but as most controls on this camera are built into the same part, this repair

More information

Hardware Replacement Guide

Hardware Replacement Guide Hardware Replacement Guide Types 6491, 8013, 8702, 8706 Types 8716, 8970, 8972, 8976 Types 8980, 8982, 8986, 8992 Types 8994, 9266, 9276, 9278 Types 9282, 9286, 9288, 9374 Types 9378, 9380, 9384, 9628

More information

Replacing an Advanced Power and Cooling (APC) Unit

Replacing an Advanced Power and Cooling (APC) Unit Replacing an Advanced Power and Cooling (APC) Unit You must replace a failed APC unit as quickly as possible (within minutes) to maintain correct airflow and cooling. Failed APC units can be hot-swapped.

More information

XTM 1050 Replacement Parts Installation

XTM 1050 Replacement Parts Installation XTM 1050 Replacement Parts Installation Instructions to replace or install: Power Supply Chassis Fan Fiber Card 10 Gb Interface Module WARNING! Do not open the XTM 1050 or try to replace or install any

More information

FRU Installation Notes Virtuo Monitor Glass Replacement

FRU Installation Notes Virtuo Monitor Glass Replacement January 2016 900975-001 Rev 00 FRU Installation Notes Virtuo Monitor Glass Replacement Purpose How to replace the touch screen glass on a Virtuo This document is for these components or categories Expected

More information

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment FAST SHIPPING AND DELIVERY TENS OF THOUSANDS OF IN-STOCK ITEMS EQUIPMENT DEMOS HUNDREDS OF MANUFACTURERS SUPPORTED

More information

Installing the Server into a Rack

Installing the Server into a Rack Installing the Server into a Rack Note These instructions apply to multiple models; illustrations may vary slightly. Rack Mount Kit Inventory Before installing the chassis on a standard 4-post rack, make

More information

Presario 1200 Series Models: XL101-XL113, XL115, XL118-XL127. This section explains the removal and replacement procedures for the 1200XL unit.

Presario 1200 Series Models: XL101-XL113, XL115, XL118-XL127. This section explains the removal and replacement procedures for the 1200XL unit. Removal Sequence Presario 1200 Series This section explains the removal and replacement procedures for the 1200XL unit. Serial Number Location Report the unit s serial number 1 to Compaq when requesting

More information

Cisco TelePresence VX Clinical Assistant TM

Cisco TelePresence VX Clinical Assistant TM Cisco TelePresence VX Clinical Assistant TM ACCESSORIES INSTALLATION GUIDE Drawer Module, PC Cabinet Module, PC Shelf, and Storage Pods...2 Laptop Shelf...3 Scope Hooks, WAP Mount, and Splash Cover...4

More information

Maintaining the Avaya S8800 Server for Avaya Aura SIP Enablement Services

Maintaining the Avaya S8800 Server for Avaya Aura SIP Enablement Services Maintaining the Avaya S8800 Server for Avaya Aura SIP Enablement Services 03-603448 Issue 1 November 2009 2011 Avaya Inc. All Rights Reserved. is 1-800-242-2121 in the United States. For additional support

More information

HP EVA4400 M6412 drive enclosure

HP EVA4400 M6412 drive enclosure HP EVA4400 M6412 drive enclosure installation instructions HP Part Number: 5697-0975 Published: June 2011 Edition: Second Copyright 2008, 2011 Hewlett-Packard Development Company, L.P. About this document

More information

RMX 2000/4000 MPMx Migration Procedure

RMX 2000/4000 MPMx Migration Procedure RMX 2000/4000 MPMx Migration Procedure Prior to initiating this procedure make sure you are entitled to version 7.0 in your Support Agreement. The MPMx requires software version 7.0 installed. First complete

More information

Replacement Instructions. Backplane PCA for the HP Router 650

Replacement Instructions. Backplane PCA for the HP Router 650 Replacement Instructions Backplane PCA for the HP Router 650 Copyright Hewlett-Packard Company 1994. All rights reserved. Publication Number 5962-8369 Edition 1, August 1994 Printed in USA This guide provides

More information

Removing and Replacing Parts

Removing and Replacing Parts Removing and Replacing Parts Preparing to Work Inside the Computer Recommended Tools Screw Identification System Components Hard Drive Fixed Optical Drive Media Bay Devices Memory Modules Mini PCI Card

More information

Dell Alienware 13 R3 Heat-Sink Assembly

Dell Alienware 13 R3 Heat-Sink Assembly Dell Alienware 13 R3 Heat-Sink Assembly Replacement In this guide, we will show you how to remove and replace the Heat-Sink Assembly. Written By: Teren Wallace ifixit CC BY-NC-SA www.ifixit.com Page 1

More information

ThinkCentre. Hardware Removal and Replacement Guide Types 8143, 8144, 8146 Types 8422, 8423, 8427

ThinkCentre. Hardware Removal and Replacement Guide Types 8143, 8144, 8146 Types 8422, 8423, 8427 ThinkCentre Hardware Remoal and Replacement Guide Types 8143, 8144, 8146 Types 8422, 8423, 8427 ThinkCentre Hardware Remoal and Replacement Guide Types 8143, 8144, 8146 Types 8422, 8423, 8427 First Edition

More information

Packard Bell. EasyNote BU Series. Disassembly Guide

Packard Bell. EasyNote BU Series. Disassembly Guide Packard Bell EasyNote BU Series Disassembly Guide Table of Contents Overview...3 Technician Notes...3 Disassembly Instructions...3 Reassembly Instructions...3 Required Tools...3 Battery...4 Memory...4

More information

H4 Series Hardware Replacement Guide

H4 Series Hardware Replacement Guide Machine type: 10059/7723 10060/7724 10068/7752 10080/3099/1194 10091/2558/1196 H4 Series Hardware Replacement Guide Version 3.0 2011.08 31500379 Hardware Replacement Guide Copyright Lenovo 2011. All rights

More information

Written By: Teren Wallace

Written By: Teren Wallace In this guide, we will be showing you how to remove and replace the Touch Pad. Written By: Teren Wallace ifixit CC BY-NC-SA www.ifixit.com Page 1 of 26 INTRODUCTION In this guide, we will be showing you

More information

RMX 2000/4000 MPMx Migration Procedure

RMX 2000/4000 MPMx Migration Procedure RMX 2000/4000 MPMx Migration Procedure Guidelines Prior to the installation make sure: You are entitled to the Support Agreement Control Unit memory size is at least 1024MB. To check the RMX Memory size,

More information

Megatouch FORCE Monitor Chassis Board Replacement

Megatouch FORCE Monitor Chassis Board Replacement Megatouch FORCE Monitor Chassis Board Replacement Visit the Merit Industries, Inc. Web site http://www.meritind.com merit industries, inc. PM0337-01 Rev C Table of Contents FORCE Classic Monitor Chassis

More information

MegaRAID Remote Kit for the LSIiBBU06, LSIiBBU07, and LSIiBBU08 Intelligent Battery Backup Units. Quick Installation Guide

MegaRAID Remote Kit for the LSIiBBU06, LSIiBBU07, and LSIiBBU08 Intelligent Battery Backup Units. Quick Installation Guide MegaRAID Remote Kit for the LSIiBBU06, LSIiBBU07, and LSIiBBU08 Intelligent Battery Backup Units Quick Installation Guide Version A July 2010 Revision History Version and Date Version A, July 2010 Initial

More information

SG-S to -30 Upgrade Kit. Product Installation Guide

SG-S to -30 Upgrade Kit. Product Installation Guide SG-S400-20 to -30 Upgrade Kit Product Installation Guide Legal Notice Copyright 2017 Symantec Corp. All rights reserved. Symantec, the Symantec Logo, the Checkmark Logo, Blue Coat, and the Blue Coat logo

More information

Installation Note. 8719D, 8720D, and 8722D Network Analyzer Option 1D5 High Stability Frequency Reference Upgrade Kit

Installation Note. 8719D, 8720D, and 8722D Network Analyzer Option 1D5 High Stability Frequency Reference Upgrade Kit Installation Note 8719D, 8720D, and 8722D Network Analyzer Option 1D5 High Stability Frequency Reference Upgrade Kit Agilent Part Number: 08720-90318 Printed in USA April 2002 Supersedes April 1997 Notice.

More information

Service Manual - Memory Upgrade

Service Manual - Memory Upgrade Inspiron 14 3000 Series Service Manual - Memory Upgrade Regulatory Model: P53G Regulatory Type: P53G002 Contents Before working inside your computer...3 Before you begin... 3 Safety instructions... 3 Recommended

More information

Replacing the Gateway M275 Keyboard

Replacing the Gateway M275 Keyboard Replacing the Gateway M275 Keyboard This package includes a replacement keyboard for your Gateway M275 notebook and these printed instructions. Tools you need You need a small Phillips screwdriver and

More information

DualShock 4 Analog Stick Covers Replacement

DualShock 4 Analog Stick Covers Replacement DualShock 4 Analog Stick Covers Replacement Replace analog stick covers on the Dualshock 4 controller. Written By: Maaz Hussaini ifixit CC BY-NC-SA www.ifixit.com Page 1 of 9 INTRODUCTION Use this guide

More information

hp uninterruptible power system r12000 xr models installation instructions

hp uninterruptible power system r12000 xr models installation instructions hp uninterruptible power system r000 xr models installation instructions Overview These instructions show how to install an uninterruptible power system (UPS). For detailed information about the UPS, refer

More information

SRP Field Upgrade Installation Instructions

SRP Field Upgrade Installation Instructions SRP Field Upgrade Installation Instructions 03 November 2004 Part No: 162-00982-00 Revision A01 This document describes installation procedures for upgrading switch route processor (SRP) modules, I/O modules,

More information

Field Service Guide Supplement for the NS 7000/030

Field Service Guide Supplement for the NS 7000/030 AUSPEX Field Service Guide Supplement for the NS 7000/030 Copyright 1998, Auspex Systems, Inc. All rights reserved. Part number 850550. Important Notice The installation or replacement procedures in this

More information

CRESCENDO /7200 G3. Quick Start Guide for Crescendo /7200. Processor Upgrade Card for Power Macintosh 7200/8200 Computers

CRESCENDO /7200 G3. Quick Start Guide for Crescendo /7200. Processor Upgrade Card for Power Macintosh 7200/8200 Computers CRESCENDO /7200 G3 Processor Upgrade Card for Power Macintosh 7200/8200 Computers Quick Start Guide for Crescendo /7200 System Compatibility At this printing, processor upgrade cards are compatible with

More information

Sabio Digital SD-KN1 Notebook Assembly Guide

Sabio Digital SD-KN1 Notebook Assembly Guide Sabio Digital SD-KN1 Notebook Assembly Guide Rev. 1.4 Sabio Digital KN1 Assembly Guide 1 of 11 www.sabioproducts.com Table of Contents Section 1.0 - Overview... 3 Section 2.0 - Before You Begin... 3 Section

More information

Technovision Inc. CD-ROM Audio Sampler. Repair Manual

Technovision Inc. CD-ROM Audio Sampler. Repair Manual Technovision Inc. CD-ROM Audio Sampler Repair Manual Table Of Contents: Page # INITIAL SETUP & TESTING 3 System Components 3 System Set-Up Procedure 3 Self Test Routine 3 REPAIR ACTION PARTS REPLACEMENT

More information

Replacement Keyswitch Assembly

Replacement Keyswitch Assembly Installation Instructions Replacement Keyswitch Assembly (Catalog No. 2711E-NKSW1) Applicable Terminals Use this replacement keyswitch with PanelView Terminals 2711-KA1, -KC1, -TA1, -TC1, -TA4, -TC4 and

More information

Dell Latitude V710/V740 Service Manual

Dell Latitude V710/V740 Service Manual Dell Latitude V710/V740 Service Manual Dell Latitude V710/V740 Service Manual Before You Begin Preparing to Work Inside the Computer Recommended Tools Computer Orientation Screw Identification System Components

More information

Samsung Galaxy Tab Speaker

Samsung Galaxy Tab Speaker Samsung Galaxy Tab 2 10.1 Speaker Replacement This guide will show you how to replace a broken speaker in your tablet. Written By: Matthew Weeman ifixit CC BY-NC-SA www.ifixit.com Page 1 of 11 INTRODUCTION

More information