~ _ Mir1<oBalaz

Size: px
Start display at page:

Download "~ _ Mir1<oBalaz"

Transcription

1 NTERNATONAL ELECTROTECHNCAL COMMSSON EC Certification Scheme for Explosive Atmospheres for rules and details of the ECEx Scheme visit Certificate No.: r Status: Current Date of ssue: Certificate history: ~ ssuùlò.'1 (20157':Ù), ssue No. O (201257) issue NO.:1 ~ ~ _ Page 1 of4 ATOS S.p.A. Applicant: Via alla Piana, Sesto Calende 0/A) ltaly W..J ct C Z w ~ o l) :l Electrical Apparatus: Optional accessory: Explosion proof inductive Type of Protection: Flameproof Mar1<ing: Ex d C T6 or TS or T4 Gb Ex tb mc T8S C or T1 OO C or T13S C Ob P66/67 enclosures transducers, 'd'; Oust ignition type ETHA4/. protection Approved for issue on beha/f of the ECEx Certification Body: Mir1<oBalaz Position: Head of ECEx CB by enclosure "t" Signalure: (for prinled version) Date: 1. This certificate and schedule may only be reproduced in full. 2. This certificate is not transferable and remains the property of the issuing body. 3. The Status and authenticity of this certificate may be verified by visiting the Official ECEx Website. Certificate issued by: ' CES Centro Elettrotecnico Sperimentale taliano S.p.A. Via Rubattino Milano ltaly CES CES S.p.A. Testing & Certificatio~ Division 'nes rea Cerllficallon / R sponsabile _. /J ' ( berto Piccini j

2 ~ Certificate No.: Date of ssue: ssue No.: 1 Page 2 of4 ATOS S.p.A. Manufaclurer: Via alla Piana, Sesto Calende (ya) ltaly Additional Manufacluring localion(s): This certificate is issued as verificalion that a sample(s), representalive of prcduction, was assessed and tested and found lo comply wilh he EC Slandard lis below and that the manufaclurer's quality system, relaling to the Ex products covered by this certificate, was assessed and found to comply with the ECEx Quality system requirements. This certificate is granled subjecl to he conditions as se out in ECEx Scheme Rules, ECEx 02 and Operational Oocuments as amended. STANOAROS: The electrical apparatus and any acceptable variations to it specified in the schedule of his certificate and he idenlified documents, was found lo comply wilh he following standards: EC Edition: 6.0 EC Edition: 6 EC Edilion: 2 o: Generai : 2011 Explosive atmospheres Part : Explosive atmospheres Part 1: Equipment prolection by f1ameproof enclosures "d" : 2013 requiremenls Explosive atmospheres Part 31: Equipment dust ignilion prolection by endosure This Certificate does not indicate compliance with electrical safety and performance express/y included in the Standards listed above. TEST & ASSESSMENT requirements other than those REPORTS: A sample(s) of tha equipment listed has successful1y met the examination and test requirements as recorded in Test Report: T/CES/ExTR l00 Qualitv Assessmenl Report: T/CES/QAR /04 ' T/CES/ExTR l01 "t"

3 Certificate No.: Date of ssue: ssue No.: 1 Page 3 of4 Schedule, EQUPMENT: Equipment and systems covered by this certificate Bre BS follows: The lnductive transducers type ETHA4r are used separately for detect a positionor coupling with explosion prooi solenoids type OZA T for detect the positions of the spools of directional or flow control proportional valves. Electrical characteristics: Supply voltage: ± 15 VDC stabilized Max current consumption: 28 ma Max power consumption: < 1 W Ambient temperature range: from 40 C to + 40 C, and from 40 C to +70 C. Degree of protection: P 66/67 (EC 60529). For further information see Annex. J CONDTONS OF CERTFCATON: VES as shown below: The flamepaths are specified in the manutacturer drawings. Far information regarding the dimenslons of the flameproof joints the manufacturer shall be contacted. For the selection of connecting cable with operating temperature suitable for the installation conditions of equipment refer to the manufacturer safety instruction. The conditions of the installation of the equipment are included within the safety instructions. For a safe use these assembling instructions are to be followed precisely. J

4 Certificate No.: Date of lssue: ssue No.: 1 Page 4 of4 DETALS OF CERTFCATE CHANGES (for issues 1 and above): Variation 1.1 The explosion proof inductive transducer, originally assessed in compliance with EC : 2007, EC : 2007 and EC :2008 have been reassessed on the basis of the standard EC : th edition and EC ' :2013 2nd edition. Variation 1.2 Name plate modification.dimensions and contents are being revised to allow the multicertification of the solenoid. Variation 1.3 dentification code updating. The identification codes of the equipment have been revised in order to use the same code for ali certification scheme. L._ Annex: ::::::=:::~:: ECExCES X ssue 1 ANNEXATOS.pdf '

5 CES Prot: B50lR13 Annex to certificate: Applicant: ATOS S.p.A. via alla Piana, 57; Sesto Calende (VA), taly Electrical Apparatus: Explosion proof inductive transducers, ssue NO.1 of type ETHA4/. Description of equipment The inductive transducers type ETHA4/* are used separately for detect a position or coupling with explosion proof solenoids type OZAT for detect the positions of the spools of directional or flow control proportional valves. The following versions with the relevant model code are available: Model code W C!i Z w N <t o Vl :: Description ETHA4/1 With voltages output, voltage resolution 3,3 V/mm ETHA4/2 With voltages output, voltage resolution 2,5 V/mm ETHA4/4 With voltages output, voltage resolution 1,25 V/mm ETHA4/8 With voltages output, voltage resolution 0,6 V/mm ETHA4/C With current output 4 20 ma or 020 converter circuit is used ma, a voltages to current Max. ambient temperature, temperature class, surface temperature, Model [l) [21 connecting cable temperature Maxambient temperature Temperature class Surface temperature Connecting cable temperature ETHA4/. (1) 40 C T6 T85 C ETHA4/. ETHA41. l) 70 C 40 C T6 T85 C T100 C ~90 C T5 ETHA4/. [2) 70 C T4 T135 C ~ 120 C [2) ~ 90 C Coupled to mechanical parts that not influencing the temperature class. Coupled to proportional transducer type OZAT subject of a separate certification. Cable entries The cable entry devices used on the enclosure shall be suitably certified according to the applicable standards. For the equipment with dust protection 'tb' the accessories used for cable entries and for unused holes shall guarantee the degree of protection P66/67 according to EC standard. Warning label "Warning do not open when energized" "For the correct selection of connecting cable temperatures see safety instructìons" Page1 of 1 CES Centro Elettrotecnico Sperimentale taliano SpA; Milano talia

6 Declaration of conformity TT307/1 ~ A Atos spa al!jo)5 ~ The Company ATOS s.p.a Sesto Calende talia via alla Piana 57 Hereby declares the conformity to ECEx scheme, of the Products Prodotto 1Product TRASDUTTORE NDUTTVO NDUCTVE TRANSDUCER Tipo 1 Type ETHA4/* Protection mode Ex d C T6, T5, T4 Gb Ex tb C T85 C, T100 C, T135 C Db P66/67 ECEx certificate n. EC (6 th ed.) [!] EC (6 th ed.) [! n accordance with the following EC standards EC (2 nd ed.) [! CES protocollo allegato al documento Date: 08/05/2015 Signature: o o o o o o o o o o o o o o o o o o o o o Pago 1/1

IECEx Certificate of Conformity

IECEx Certificate of Conformity --- Certificate : ECEx PTB 13.0036X Seite 1 von 5 ECEx Certificate ------ -- l "-- - --- --- NTERNATONAL ELECTROTECHNCAL COMMSSON EC Certification Scheme for Explosive Atmospheres for rules and details

More information

IECEx Certificate of Conformity

IECEx Certificate of Conformity INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Certificate No.: Status: IECEx FTZU 14.0004X Current

More information

IECEx Certificate of Conformity

IECEx Certificate of Conformity INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Certificate No.: IECEx LCI 10.0010X issue No.:1

More information

IECEx Certificate of Conformity

IECEx Certificate of Conformity IECEx Certificate of Conformity INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Certificate No.:

More information

INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres

INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Certificate No.: Status: Date of lssue: Applicant:

More information

IECEx Certificate of Conformity

IECEx Certificate of Conformity INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Certificate No.: IECEx PTB 05.0013 issue No.:2

More information

IECEx Certificate of Conformity

IECEx Certificate of Conformity INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Certificate No.: Status: IECEx UL 15.0032X Current

More information

IECEx Certificate of Conformity

IECEx Certificate of Conformity Certificate : IECEx PTB 04.0005 http://iecex.iec.ch/iecex/iecexweb.nsf/certificatesajax/iecex%20ptb%2004.0005%... Seite 1 von 4 10.01.2013 INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme

More information

IECEx Certificate of Conformity

IECEx Certificate of Conformity INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Certificate No.: IECEx ITA 14.0009X Issue No:

More information

IECEx Certificate of Conformity

IECEx Certificate of Conformity INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com issue No.:3 Status: Current Date of Issue: 2012-10-12

More information

IECEx Certificate of Conformity

IECEx Certificate of Conformity INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com issue No.:2 Status: Current Certificate history:

More information

Refer to attachment for more details. Andreas Meyer

Refer to attachment for more details. Andreas Meyer IECEx Certificate of Conformity INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Certificate No.:

More information

IECEx Certificate of Conformity

IECEx Certificate of Conformity IECEx Certificate of Conformity INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Certificate No.:

More information

IECEx Certificate of Conformity

IECEx Certificate of Conformity INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Certificate No.: IECEx ITA 10.0006X Issue No:

More information

IECEx Certificate of Conformity

IECEx Certificate of Conformity INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Certificate No.: IECEx BKI 07.0001X issue No.:1

More information

I Ex-Installation switch I

I Ex-Installation switch I I Ex-Installation switch I Switch/Pushbutton Technical data 4 Ex-installation switch and Ex-pushbuttons Marking accd. to 94/9/EC II 2 G Ex de IIC T6 / II 2 D Ex td A21 IP66 T80 C EC-Type Examination Certificate

More information

IECEx Certificate of Conformity

IECEx Certificate of Conformity INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the ECEx Scheme visit www.iecex.com Certificate No.: Status: Current Issue No: 1 Certificate

More information

IECEx Certificate of Conformity

IECEx Certificate of Conformity INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com issue No.:5 Status: Current Date of Issue: 2016-04-06

More information

Page 1 of 5. Increased Safety, Encapsulation and Dust

Page 1 of 5. Increased Safety, Encapsulation and Dust IEC INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www iecex com Certificate No.: Status: Date of Issue: IECEx

More information

IECEx Certificate of Conformity

IECEx Certificate of Conformity INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Certificate No.: Status: IECEx TRC 12.0010X Current

More information

IECEx Certificate of Conformity

IECEx Certificate of Conformity INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Certificate No.: issue No.:O Certificate history:

More information

(1) EC-TYPE-EXAMINATION CERTIFICATE (Translation) (2) Equipment and protective systems intended for use in potentially explosive atmospheres Directive 94/9/EC (3) EC-type-examination Certificate number

More information

IECEx Certificate of Conformity

IECEx Certificate of Conformity IECEx Certificate of Conformity INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Certificate No.:

More information

IECEx Ce ificate of Conformi

IECEx Ce ificate of Conformi IECEx Ce ificate of Conformi INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Status:. IECEx DEK

More information

IECEx Certificate of Conformity

IECEx Certificate of Conformity INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Certificate No.: issue No.:O Certificate history:

More information

INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres

INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Certificate No.: Certificate history: Issue No.

More information

ECE Cert.fic te of Con ormity

ECE Cert.fic te of Con ormity ECE Cert.fic te of Con ormity INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www iecex.com Certificate No.:

More information

IECEx Certificate of Conformity

IECEx Certificate of Conformity IECEx Certificate of Conformity Certificate No.: IECEx PTB 10.0014U Date of Issue: 2010-03-02 Issue No.: 0 Page 2 of 3 Manufacturer: BARTEC GmbH Max-Eyth-Straße 16 97980 Bad Mergentheim Germany Manufacturing

More information

Coil Type 3009M. This document cannot be modified without the approval of the Certification Institute 1/4

Coil Type 3009M. This document cannot be modified without the approval of the Certification Institute 1/4 Coil Type 3009M Coil Type 3009M UE DECLARATION OF CONFORMITY 1/4 Coil Type 3009M COIL 3009M II 2G Ex mb IIC Tx Gb II 2D Ex tb IIIC Tx C Db to be used in potentially explosive atmosphere We, AMISCO S.p.A.,

More information

IECEx Certificate of Conform ity

IECEx Certificate of Conform ity -------- -- - IECEx Certificate INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certitication Scheme tor Explosive Atmospheres tor rules and details of the IECEx Scheme visit v..ww.iecex.com Certificate

More information

slra IEC IECEx Certificate of Conformity 2n t7 - Oó. /j /.4. csa Gluup cërllftcattoh ExdbiaopislMb Ex tb lllc T100'C Db or Ex db ia op is llc T5 Gb

slra IEC IECEx Certificate of Conformity 2n t7 - Oó. /j /.4. csa Gluup cërllftcattoh ExdbiaopislMb Ex tb lllc T100'C Db or Ex db ia op is llc T5 Gb -a IM Ex Certificate I NTERNATIONAL ELECTROTECH N I CAL COMM ISSION Certification Scheme for Explosive Atmospheres for rules and details of the Ex Scheme visit www.iecex.com Certificate No.: Status: Ex

More information

Do not open when energized or when an explosive atmosphere is present. Electrostatic hazard, clean only with damp cloth.

Do not open when energized or when an explosive atmosphere is present. Electrostatic hazard, clean only with damp cloth. D460/D470 Series - ATEX certified position transmitter nnnn II 2 GD ITS 11 ATEX 17431X Ex d IIC T* Gb Tamb -*ºC to +*ºC Ex tb IIIC T* Db Tamb -*ºC to +*ºC IP6X Ambient variation -60 C to +110 C (T4/T130

More information

Micro Motion, Inc. Page 1 of 6

Micro Motion, Inc. Page 1 of 6 EB-20025742 Revision: AA Number of Pages: 6 Comments: Originator: HVH 10/01/13 Approved: RCS 11/26/13 Rev ECN Description Approval Date AA 1049085 Release to Approvals RCS 11/26/13 Micro Motion, Inc. Page

More information

ADAMCZEWSKI. Ordering data AD-STVEX 710 GVD Option: Factory-software configuration as per customer specifications.

ADAMCZEWSKI. Ordering data AD-STVEX 710 GVD Option: Factory-software configuration as per customer specifications. EN ADAMCZEWSKI Elektronische Messtechnik GmbH Felix-Wankel-Str. 13 / 74374 Zaberfeld Tel. +49 (0)7046-875 Fax +49 (0)7046-7678 vertrieb@ad-messtechnik.de Operating Instructions Supply Isolation Amplifier

More information

ACCREDITED AND APPROVED TEST LABORATORY IN TERMS OF ARP 0108: REGULATORY REQUIREMENTS FOR EXPLOSION PROTECTED APPARATUS

ACCREDITED AND APPROVED TEST LABORATORY IN TERMS OF ARP 0108: REGULATORY REQUIREMENTS FOR EXPLOSION PROTECTED APPARATUS Government Approved Test Laboratory (Previously AIA) Reg No: 1999/027771/07 ACCREDITED AND APPROVED TEST LABORATORY IN TERMS OF ARP 0108: REGULATORY REQUIREMENTS FOR EXPLOSION PROTECTED APPARATUS IA CERTIFICATE

More information

Interface and Supply module. IPC 3x0i / PSC 3x0i

Interface and Supply module. IPC 3x0i / PSC 3x0i Interface and Supply module IPC 3x0i / PSC 3x0i Installation Guide Version 10 IBS BatchControl GmbH Im Sträßchen 2 4 Tel.: +49 2241 9199801 53925 Kall Fax.: +49 2241 9199871 Germany www.ibs-batchcontrol.com

More information

Operating Instructions

Operating Instructions Introduction To protect the signal lines of field devices and systems in the cabinet against lightning. Pepperl+Fuchs covers the complete range of Surge Protection Barriers. Housing types Depending on

More information

M E M O R A N D U M I.S.

M E M O R A N D U M I.S. Physikalisch-Technische Bundesanstalt Department 3.6 " Intrinsic safety and Safety of Systems" 38023 Braunschweig Germany P.O. Box 33 45 Tel. ++49 531 592-3630 Fax ++49 531 592-3605 M E M O R A N D U M

More information

IECEx Certificate of Conformity

IECEx Certificate of Conformity INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Status: Current Page 1 of 5 issue No.:1 Certificate

More information

IECEx Certificate of Conformity

IECEx Certificate of Conformity IECEx Certificate of Conformity INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Certificate No.:

More information

IECEx Certificate of Conformity Annexe

IECEx Certificate of Conformity Annexe for Certificate No.: IECEx TSA 08.0044X Issue No.: 1 Equipment pertaining to Issue 0 of this Certificate: The Flameproof Power Supply Type C4000 is manufactured from cast aluminium and comprises a base

More information

The 470-Z1 consists of an aluminium enclosure, which has the supply / interface connections either via the bottom side or enclosure back panel.

The 470-Z1 consists of an aluminium enclosure, which has the supply / interface connections either via the bottom side or enclosure back panel. February 23, 2018 Annexe to: IECEx CML 15.0097X Issue 4 Applicant: Apparatus: HMI Elements Limited 470-Z1 Module Description of Equipment The 470-Z1 is a mains supplied, transportable hazardous area

More information

Operating instructions (Safety-related part ATEX and IECEx) Inductive NAMUR sensors NN504A NN505A NN506A NN507A /00 08/2015

Operating instructions (Safety-related part ATEX and IECEx) Inductive NAMUR sensors NN504A NN505A NN506A NN507A /00 08/2015 Operating instructions (Safety-related part ATEX and IECEx) Inductive NAMUR sensors NN504A NN505A NN506A NN507A 80013497/00 08/015 Remarks for safe use in hazardous areas Functions and features Use in

More information

Ex Certificate of Conformity

Ex Certificate of Conformity Standard Form for Evaluation of the Quality Management System used in the Production Process and Product Testing Issue date: 09-10-2015 Page 1 of 5 Expiration date: 09-10-2018 Applicant: Electrical apparatus:

More information

Operating Manual / IEC. Explosion-Proofed Junction Boxes, Polyester. Wallücker Bahndamm 7 DE Kirchlengern

Operating Manual / IEC. Explosion-Proofed Junction Boxes, Polyester. Wallücker Bahndamm 7 DE Kirchlengern Operating Manual / IEC Explosion-Proofed Junction Boxes, Polyester Wallücker Bahndamm 7 DE- 32278 Kirchlengern Tel.: +49 5223 49107-0 Fax: +49 5223 49107-28 info@multi-box.com www.multi-box.com Contents

More information

INSTRUCTION MANUAL. SIL 3 Relay Output Module DIN-Rail Models D1092S-069, D1092D-069 D1092S D1092D-069

INSTRUCTION MANUAL. SIL 3 Relay Output Module DIN-Rail Models D1092S-069, D1092D-069 D1092S D1092D-069 D09S09 D09D09 INSTRUCTION MANUAL SIL Relay Output Module DINRail Models D09S09, D09D09 D0909 SIL Relay Output Module ISM00 SIL Applications For Safety Related System and SIL, SIL Applications according

More information

FLEX Ex Spring Clamp Terminal Base

FLEX Ex Spring Clamp Terminal Base Installation Instructions FLEX Ex Spring Clamp Terminal Base (Cat. No. 1797-TB3S) 1 10 11 4 Only remove this cover plug if connecting another terminal base unit. 3 5 6 12 2 7 8 9 41253 Component Identification

More information

Signal processor MS96 for flow sensors MS96-11EX0-R/230VAC

Signal processor MS96 for flow sensors MS96-11EX0-R/230VAC MS96-11EX0-R/230VAC ATEX category II (1) G, Ex Zone 0 ATEX category II (1) D, Ex Zone 20 single-channel signal processor MS96 for connection of an intrinsically safe flow control sensor in zone 0 adjustment

More information

Certificate of Conformity Ex EQUIPMENT

Certificate of Conformity Ex EQUIPMENT Applicant: ecom instruments GmbH Industriestrasse 2 97959 Assamstadt Germany Equipment: Intrinsically Safe TRUE RMS MULTIMETER Fluke 28 II EX Type of Explosion Protection: Explosion Protection Marking:

More information

This installation guide provides instructions for installing the SPARTAN HP Highbay/ Floodlight series of explosion protected floodlights.

This installation guide provides instructions for installing the SPARTAN HP Highbay/ Floodlight series of explosion protected floodlights. SPX/SPZ SPARTAN HIGH POWER LUMINAIRE RANGE Installation Guide Zone 1 Variant - CML17ATEX1148 & IEC Ex CML17.0074 Zone 2 Variant - CML17ATEX4149 & IEC Ex CML17.0074 This installation guide provides instructions

More information

Control Switches for Panel Mounting Series 8003

Control Switches for Panel Mounting Series 8003 > Switch function many switching arrangements ( or spring-return) possible via coding easy change of the coding possible on site max. 2 pole > For > With flexible lead or spring cage terminal www.stahl.de

More information

Certificate of Conformit r IECExPTB 10.0018X htþ://iecex.iec.ch/iecex/iecexweb.nsfl42 I ce88 1 5c53a3afcl257 ale... ts IECEx Gertificate of Conformity INTERNATIONAL ELECTROTECHNICAL COMMISSION IEG Certification

More information

Digital Output Module 4-Channel Version for Zone 1 Series 9475/

Digital Output Module 4-Channel Version for Zone 1 Series 9475/ www.stahl.de > 4-channel digital output > Intrinsically safe outputs Ex ia > For Ex i solenoid valves and display elements > Additional Ex i control input for "Plant STOP" (acc. IEC61508 up to SIL2) >

More information

YT-870 / 875 Series. Rotork YTC Limited VERSION 1.06

YT-870 / 875 Series. Rotork YTC Limited VERSION 1.06 PRODUCT MANUAL Rotork YTC Limited VERSION 1.06 Contents 1 Introduction... 3 1.1 General Information for the users... 3 1.2 Manufacturer Warranty... 3 1.3 Explosion Proof Warning... 4 2 Product Description...

More information

Digital Output Module 8-Channel Version for Zone 2 Series 9475/

Digital Output Module 8-Channel Version for Zone 2 Series 9475/ > 8-channel digital output > Intrinsically safe outputs Ex ia > For Ex i solenoid valves and display elements > Line fault monitoring per channel > Diagnostics based on NE107 > Module can be replaced in

More information

Certificate of Conformity

Certificate of Conformity Applicant: Electrical Apparatus: Type of Protection: Marking Code: Manufacturer: Manufacturing Location: Seamless Mining Products Pty Ltd Unit 3/29 Mustang Drive Rutherford NSW 2320 11 kv 800 A Type A

More information

Explosion-Protected Arc-Fault Protection ExAFCI Arc-Fault Circuit Interrupter

Explosion-Protected Arc-Fault Protection ExAFCI Arc-Fault Circuit Interrupter Installation, Operation & Maintenance Sheet Explosion-Protected Arc-Fault Protection ExAFCI Arc-Fault Circuit Interrupter > Contents 1 Contents 1 Contents...2 2 General Information...2 2.1 Manufacturer...2

More information

Digital Output Module 8-Channel Version for Zone 2 Series 9475/

Digital Output Module 8-Channel Version for Zone 2 Series 9475/ > 8-channel digital output > Intrinsically safe outputs Ex ia > For Ex i solenoid valves and display elements > Line fault monitoring per channel > Diagnostics based on NE107 > Module can be replaced in

More information

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm. Short-circuit protection

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm. Short-circuit protection NCN-FK-N-V-V 002 Model Number NCN-FK-N-V-V Features Direct mounting on standard actuators Compact and stable housing with terminal compartment connection Fixed setting EC-Type Examination Certificate TÜV99

More information

Inductive sensor Dual sensors with extended temperature range NI4-DSU35TC-2Y1X2/S97

Inductive sensor Dual sensors with extended temperature range NI4-DSU35TC-2Y1X2/S97 ATEX category II 2 G, Ex zone 1 ATEX category II 1 D, Ex-zone 20 for temperatures up to -25 C SIL2 acc. to IEC 61508 Rectangular, housing DSU35 Plastic, PP-GF30-VO Two outputs for monitoring the position

More information

INSTRUCTION MANUAL. Universal AC Input Switching Power Supply 24 Vdc Output DIN-Rail Models PSD1000, PSD1000F PSD PSD1000F

INSTRUCTION MANUAL. Universal AC Input Switching Power Supply 24 Vdc Output DIN-Rail Models PSD1000, PSD1000F PSD PSD1000F PSD1000 - PSD1000F INSTRUCTION MANUAL Universal AC Input Switching Power Supply 24 Vdc Output DIN-Rail Models PSD1000, PSD1000F PSD1000 - Universal AC Input Switching Power Supply 24 Vdc Output ISM0089-4

More information

EX- Documentation VA 450 / VA 452. thermal mass flow sensor

EX- Documentation VA 450 / VA 452. thermal mass flow sensor EX- Documentation VA 450 / VA 452 thermal mass flow sensor This document contains important information for the installation and operation of the flow sensor in explosive environments. Please read the

More information

How to calculate an Intrinsically Safe loop approval.

How to calculate an Intrinsically Safe loop approval. MIE TALK - October 2016 How to calculate an Intrinsically Safe loop approval. EXPLOSIVE ATMOSPHERES Compile by: Gary Friend BSc PrEng, CEng MIET, Sales DirectorExtech Safety Systems (MTL, Beka Associates,

More information

D1093S INSTRUCTION MANUAL. D SIL 3 Relay Output Module with Line and Load diagnostics. DIN-Rail Model D1093S

D1093S INSTRUCTION MANUAL. D SIL 3 Relay Output Module with Line and Load diagnostics. DIN-Rail Model D1093S D109S INSTRUCTION MANUAL SIL Relay Output Module with Line and diagnostics DINRail Model D109S D109 SIL Relay Output Module with Line and diagnostics ISM0096 SIL Applications For Safety Related System

More information

Uncertified Translation Physikalisch-Technische Bundesanstalt Braunschweig und Berlin (1) EC Type Examination Certificate (2) Equipment and Protective Systems Intended for Use in Potentially Explosive

More information

IECEx Certificate of Conformity

IECEx Certificate of Conformity IECEx Certificate of INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Certificate No.: Status:

More information

Digital Output Module 8-Channel Version for Zone 1 Series 9475/

Digital Output Module 8-Channel Version for Zone 1 Series 9475/ www.stahl.de > 8-channel digital output > Intrinsically safe outputs Ex ia > For Ex i solenoid valves and display elements > Additional Ex i control input for "Plant STOP" (acc. IEC61508 up to SIL2) >

More information

Installation & Operation Manual

Installation & Operation Manual Via Enrico Fermi, 2 I-25015 Desenzano del Garda (BS) - Italy Phone: +39 030 7870787 Fax: +39 030 7870777 www.solexy.net BAF Intrinsically Safe Ethernet Coupler for signals operating in Hazardous Areas

More information

SUPPLEMENTARY TYPE EXAMINATION CERTIFICATE

SUPPLEMENTARY TYPE EXAMINATION CERTIFICATE 1. SUPPLEMENTARY TYPE EXAMINATION CERTIFICATE 2. Equipment or Protective System Intended for use in Potentially Explosive Atmospheres Directive 94/9/EC 3. Type Examination Certificate Number: ITS13ATEX47876X/1

More information

Installation & Operation Manual

Installation & Operation Manual Via Enrico Fermi, 2 I-25015 Desenzano del Garda (BS) - Italy Phone: +39 030 7870787 Fax: +39 030 7870777 www.solexy.net BAF Intrinsically Safe Ethernet Coupler for signals operating in Hazardous Areas

More information

Intrinsic Safety Control Drawing

Intrinsic Safety Control Drawing s Intrinsic Safety Control Drawing system in total PLC PC Not hazardous area PROFIBUS DP Associated Apparatus Class I, DIV 2, GP A...D Class I, ZN 1, IIC T4 PROFIBUS-DP Ex i Terminating resistor Class

More information

Certificate of Compliance

Certificate of Compliance Certificate of Compliance Certificate: 70013111 (064969_0_000) Issued to: MSA - The Safety Company 1000 Cranberry Woods Dr Cranberry Township, Pennsylvania 16066-5296 USA Attention: Stephen Kancel The

More information

Digital Output Module 4-Channel Version for Zone 1 Series 9475/

Digital Output Module 4-Channel Version for Zone 1 Series 9475/ www.stahl.de > 4-channel digital output > Intrinsically safe outputs Ex ib > Suitable for Ex i hydraulic valves and solenoid valves > Additional Ex i control input for (in accordance with IEC 61508 through

More information

Inductive angle sensor with analog output Ri360P1-DSU35TC-ELi-Exi

Inductive angle sensor with analog output Ri360P1-DSU35TC-ELi-Exi ATEX category II 2 G, Ex Zone 1 ATEX category II 2 D, Ex Zone 21 Rectangular, housing DSU35 Plastic, PP-GF30-VO Detection of angular range 0 to 360 P1-Ri-QR14 positioning element included in delivery Measuring

More information

SMARTLINE RM76 Supplementary instructions

SMARTLINE RM76 Supplementary instructions SMARTLINE RM76 Supplementary instructions 2-wire / Guided Radar (TDR) Level Meter Supplementary Instructions for ATEX applications CONTENTS SMARTLINE RM76 1 General safety information 5 1.1 Scope of the

More information

Operating pressure (bar)

Operating pressure (bar) / poppet valves electromagnetic actuated, directly controlled G /4, /4 NPT, G /, / NPT or flanged with NAMUR Interface Main application: single operated actuators for plants Valves for safety systems up

More information

Installation Manual Series PQ-L. Electronic Module. Bulletin /UK

Installation Manual Series PQ-L. Electronic Module.  Bulletin /UK Bulletin 5715-571 /UK Installation Manual Electronic Module Gutenbergstr. 38 41564 Kaarst, Germany Tel.: (+) 2131-513-0 Fax: (+) 2131-513-230 www.parker.com Copyright Ó 2000, Note This document and other

More information

PROCESS AUTOMATION INSTRUCTION MANUAL FIELDBUS SURGE PROTECTOR F*-LBF-I1.32 F*-LBF-D1.32

PROCESS AUTOMATION INSTRUCTION MANUAL FIELDBUS SURGE PROTECTOR F*-LBF-I1.32 F*-LBF-D1.32 PROCESS AUTOMATION INSTRUCTION MANUAL FIELDBUS SURGE PROTECTOR F*-LBF-I1.32 F*-LBF-D1.32 With regard to the supply of products, the current issue of the following document is applicable: The General Terms

More information

ExBin-D Transducers for ExPro-B... sensors (probes) ExPro-B... Thermostats / humidistats ( C, % rh)

ExBin-D Transducers for ExPro-B... sensors (probes) ExPro-B... Thermostats / humidistats ( C, % rh) Transducers for ExPro-B... sensors (probes) ExPro-B... Thermostats / humidistats ( C, % rh) Electrical, explosion proof transducers only connectable to ExPro-B... thermostats and humidistats 24 VAC/DC

More information

Inductive Angle Sensor With Analog Output RI360P1-DSU35TC-ELI-EXI

Inductive Angle Sensor With Analog Output RI360P1-DSU35TC-ELI-EXI ATEX category II 2 G, Ex Zone 1 ATEX category II 2 D, Ex Zone 21 Rectangular, housing DSU35 Plastic, PP-GF30-VO Detecting angular positions of 0 to 360 P1-Ri-DSU35 positioning element included in delivery

More information

IECEx Certificate. of Conformity. lssue No. 2 (2O18-04-O5l lssue No- 1 ( ) lssue No. O ( ) 2018{4{5. Cunent Page I of 5.

IECEx Certificate. of Conformity. lssue No. 2 (2O18-04-O5l lssue No- 1 ( ) lssue No. O ( ) 2018{4{5. Cunent Page I of 5. -a @ IM Ex Certificate of Conformity INTERNATIONAL ELECTROTECH NICAL COMM ISSION Certification Scheme for E elosive Aûnospheres forrules and details of the EX Scheme visitwww. ecex.com Certilïcate No.

More information

VALVES Inline 3/2-, 5/2- & 5/3 Spool valves electromagnetic actuated, indirectly controlled G 1/4, 1/4 NPT, G 1/2, 1/2 NPT

VALVES Inline 3/2-, 5/2- & 5/3 Spool valves electromagnetic actuated, indirectly controlled G 1/4, 1/4 NPT, G 1/2, 1/2 NPT 975 Inline 3/-, 5/- & 5/3 Spool valves electromagnetic actuated, indirectly controlled G /, / NPT, G /, / NPT For single and double operated actuators Closed crossover design Add-on manual override Rectified

More information

MODEL: 6DV-B. [2] TERMINAL BLOCK 0: None (Euro terminal block at the rear of indicator module)

MODEL: 6DV-B. [2] TERMINAL BLOCK 0: None (Euro terminal block at the rear of indicator module) Field-mounted Two-wire Signal Conditioners 6-UNIT -DIGIT LOOP POWERED INDICATOR (outdoor enclosure, intrinsically safe/explosion-proof) Functions & Features -digit LED display No external power source

More information

Inductive sensor with analog output BI15-M30-LI-EXI

Inductive sensor with analog output BI15-M30-LI-EXI ATEX category II 1 G, Ex-zone 0 ATEX category II 2 D, Ex-zone 21 Threaded barrel, M30 x 1.5 Chrome-plated brass Analog+ Extended operating range 2-wire, 14 30 VDC Analog output 4 20 ma Cable connection

More information

Operating pressure. N/en/en

Operating pressure. N/en/en 660, 8007 NAMUR /, / & / spool valves electromagnetic actuated, indirectly controlled G / and NAMUR interface For single and double operated actuators Manual override with and without detent Simple design

More information

97105 Inline 3/2, 5/2 & 5/3 way spool valves electromagnetic actuated, indirectly controlled G1/4, 1/4 NPT, G1/2, 1/2 NPT

97105 Inline 3/2, 5/2 & 5/3 way spool valves electromagnetic actuated, indirectly controlled G1/4, 1/4 NPT, G1/2, 1/2 NPT 70 Inline 3/, / & /3 way spool valves electromagnetic actuated, indirectly controlled G/, / NPT, G/, / NPT Main application: single and double operated actuators TÜV-approval based on type examination

More information

DNV BUSINESS ASSURANCE

DNV BUSINESS ASSURANCE DNV BUSINESS ASSURANCE PRODUCTION QUALITY MANAGEMENT CERTIFICATE - EC Certificate No. 6139-2015-CE-USA-ACCREDIA This certificate consists of 3 pages. This is to certify that the quality management system

More information

Cradle relay AC. Electrical data Operating data (coil circuit) U N. Explosion protection Marking ATEX. II 2G Ex db e IIC Gb I M2 Ex db e I Mb I N

Cradle relay AC. Electrical data Operating data (coil circuit) U N. Explosion protection Marking ATEX. II 2G Ex db e IIC Gb I M2 Ex db e I Mb I N Cradle relay AC Cradle relay for alternating voltage, neutral, monostable. High-quality cradle relays for AC are installed as encapsulated flameproof elements in the MODEX enclosure. The IP 66 protection

More information

97105 Inline 3/2, 5/2 & 5/3 spool valves electromagnetic actuated, indirectly controlled G 1/4, 1/4 NPT, G 1/2, 1/2 NPT

97105 Inline 3/2, 5/2 & 5/3 spool valves electromagnetic actuated, indirectly controlled G 1/4, 1/4 NPT, G 1/2, 1/2 NPT 705 Inline 3/, 5/ & 5/3 spool valves electromagnetic actuated, indirectly controlled G /, / NPT, G /, / NPT For single and double operated actuators Valves for safety systems up to SIL (IEC 6508) Crossover-free

More information

Power Meter PowerMonitor 500

Power Meter PowerMonitor 500 ROCKWELL AUTOMATION PROCUREMENT SPECIFICATION PROCUREMENT SPECIFICATION PowerMonitor 500 NOTICE: The specification guidelines in this document are intended to aid in the specification of products. Specific

More information

D5090S INSTRUCTION MANUAL. D A SIL 3 Relay Output Module for NE Load. DIN-Rail and Termination Board, Model D5090S

D5090S INSTRUCTION MANUAL. D A SIL 3 Relay Output Module for NE Load. DIN-Rail and Termination Board, Model D5090S D5090S INSTRUCTI MANUAL 4 A Relay Output Module for NE, DIN-Rail and Termination Board, Model D5090S D5090-4 A Relay Output Module for NE G.M. International ISM09-3 Characteristics General Description:

More information

Zener Barriers Bulletin 937Z

Zener Barriers Bulletin 937Z Technical Data Zener Barriers Bulletin 937Z Topic Page Introduction 2 Mounting 2 Housing 3 Operating Principle 3 Specifications 6 Introduction Allen-Bradley Zener barriers are a cost-effective solution

More information

The Solid-State Decoupler (SSD)

The Solid-State Decoupler (SSD) The Solid-State Decoupler (SSD) Installation Instructions Introduction The Solid-State Decoupler (SSD) is a solid-state DC isolation/ac grounding (i.e., coupling) device design ed for use in conjunction

More information

Intrinsically Safe Barriers

Intrinsically Safe Barriers Intrinsically Safe Barriers Description Page No. Safety Barriers 464-472 Din Rail Isolated Barriers 473-488 477 Intrinsically Safe Barriers Product Overview We have simplified intrinsic safety! Cooper

More information

SMC Australia New Zealand IECEx & ATEX Compliant solenoid valves Rev 1.0

SMC Australia New Zealand IECEx & ATEX Compliant solenoid valves Rev 1.0 Eplosion Proof 3, 5 port solenoid valves IECEX compliant solenoid valves for Australia and New Zealand VF1/3/5000 Series XAR4001, XAR4002, XAR4003 VP3/5/700 Series XAR4010, XAR4011, XAR4012 VFN2000/200

More information

Material pressure (bar) (Cv (US) kv x 1,2 Seat

Material pressure (bar) (Cv (US) kv x 1,2 Seat 00 / poppet valves electromagnetic actuated, directly controlled G /, / NPT or flanged with NAMUR Interface TÜV-approval based on IEC 6 08, DIN V Valves for safety systems up to SIL Solenoid valve also

More information

INTRINSICALLY SAFE Ex ia PSU TYPE AC36W

INTRINSICALLY SAFE Ex ia PSU TYPE AC36W Title INTRINSICALLY SAFE Ex ia PSU TYPE AC36W USER MANUAL Document Number 66-184-12 Issue 10 10 Update new logo and address 2017.10.18 CW CW PC 09 Added Um as 265V, Io up to 3.3A & IIB data 2017.08.21

More information

Assembly MAU. MUX 4 Channels 8 Channels Zone 1

Assembly MAU. MUX 4 Channels 8 Channels Zone 1 Multi-Input/Output Device for Cabinet Installation Features Assembly For discrete inputs and outputs Installation in Zone 1/Div. 1, intrinsically safe Sensors in Zone 0/Div. 1 Connection to fieldbus acc.

More information

BA488CF-P PROFIBUS PA Intrinsically safe Panel mounting Fieldbus Display issue 3

BA488CF-P PROFIBUS PA Intrinsically safe Panel mounting Fieldbus Display issue 3 TR Automatyka Sp. z o. o. Tel. (+48 022) 886 10 16 www.trautomatyka.pl ul. Lechicka 14 ; 02-156 Warszawa Fax. (+48 022) 846 50 37 biuro@trautomatyka.pl BA488CF-P PROFIBUS PA Intrinsically safe Panel mounting

More information

Operating Instructions

Operating Instructions TPS S1 AC in DC out Translation of the original instructions TPS 110-400 Mains pack Operating Instructions PT 0199 BEN/C (1010) EN Table of contents Table of contents 1 About this manual...............................................

More information